1 CVGF Water Cooled Centrifugal Chillers January 2010
2 CVGF Key Features 2 stage centrifugal compressor Semi-hermetic compressor R134a refrigerant Falling film evaporator Economizer cycle NEW Tracer Adaptiview control module Unit mounted starter in 400V/50Hz : Star-delta or solid state 2
3 Benefits of a 2 stage compressor Wider range of unloading capability More surge resistant More efficient when combined w/ an economizer cycle 3
4 CVGF Compressor Design Motor Shaft Motor Housing Motor Rotor Motor Terminals Discharge Volute Bull Gear Pinion Motor Stator Oil tank including: -Pump 4 Suction Cover -Heaters -Filter
5 CVGF Compressor Design Motor speed: 3560 rpm in 60Hz 2970 rpm in 50Hz Bearings Gear Set Oil tank w/ pump, filter & heaters integrated in compressor casing 5 Impeller speed: Compressor family 500 : rpm 700 : 9605 rpm 1000: 7300 rpm
6 CVGF Motor Design Motor windings cooled by liquid refrigerant Voltages available 380/400/415V/50Hz 3300V/50Hz (not all sizes) 6600V/50Hz (not all sizes) 6
7 CVGF Motor Cooling System Condenser Motor No heat rejected in the equipment room like w/ air cooled motors Condenser Sump Filter F Liquid Refigerant Fixed Orifice No external piping needed like w/ water cooled motors Fixed Orifice Economizer Cpr 2nd Stage Evap 7
8 Benefits of a semi-hermetic compressor Motor cooled by liquid refg : windings operate at a lower T Motor heat not rejected into the equipment room : minimum 5% of kw input No maintenance on the shaft o-ring and no refg leak at the compressor shaft 8
9 Centrifugal Compressors: Range of Stability Comparison Compressor Characteristics define Chillers ability to Perform 35-55% 100% 10-25% 100% Head ( P) SURGE 18 C 13 C 24 C 30 C Head ( P) SURGE 24 C 18 C 13 C 30 C Capacity (kw) Capacity (kw) Single-Stage Double-Stage Design Point 9 Insert A double Footerstage compressor has a wider unloading capability
10 Impeller Dynamics V r α refrig flow rate V t α rpm diameter V t tangential velocity LIFT R resultant velocity diameter LOAD compressor work refrigerant flow rate V r radial velocity 10 rotational speed
11 Compressor Response to Load Decrease V t R V t R 15 C 11 C 500 Tons 1760 kw V r 250 Tons 880 kw V r 4920 CFM (2.32 m 3 /s) 2670 CFM (1.26 m 3 /s) full load part load 11
12 Benefits of CVGF 2 stage refigeration cycle Increased cooling capacity Higher overall efficiency With reduced refrigerant charge 12
13 Refrigerant Cycle : 2 stage compressor 35 C Extra cooling 30 C Gas Liquid and Gas 7 C 7 C 12 C 13 Insert The Footer economizer cycle increases the cooling effect in evaporator
14 Falling Film Evaporator Vapor refrigerant Liquid refrigerant Liquid distributor Orifice system Chilled water Tube bundle Benefits of Falling Film Evaporator: - reduced refrigerant charge - higher heat transfer 14
15 2 Stage Economizer Refrigerant vapor to second stage of compression Orifice Liquid refrigerant from condenser Liquid refrigerant to evaporator 15 Extra cooling
16 CVGF Optimized Oil Management System Fully integrated oil management system Efficient oil T control and return 16
17 CVGF Oil Cooling System Condenser Liquid refrigerant Hot oil Oil sump & pump Benefits Oil cooling integrated in overall efficiency of the chiller No external piping needed at jobsite for oil cooling Efficient and accurate oil T control Cold oil Oil cooler : Brazed Plate HX 17
18 CVGF Oil Return System Benefits The small qty of oil leaving the compressor is recovered at the bottom of the EVP Very limited qty of oil circulating in the heat exchangers >> low impact on heat transfer Refrigerant vapor 18 99% refrigerant + 1% Oil
19 19 CVGF Advanced Control
20 Tracer Adaptiview: Technical Features Easy-to-use 12 inch color, touch panel display Intuitive user interface Active & historic alarms Standard & customizable reports Standard & customizable graphs Advanced Adaptive Control technology embedded within the Tracer UC800 controller 20 Insert The Footer centrifugal chiller has never been so easy to use and manage
21 Technical Features: Interface Screen Chiller Status Area A G H Main Display Area/Home Screen Main Menu Area B C D E F Log Sheet ASHRAE Chiller Log About This Chiller Chiller Operating Modes Purge Operating Modes Improves Operator Productivity A B C At-a-Glance status D Graphs Intuitive navigation E Security levels Reports F 24 selectable languages 21 Insert An Intuitive/Easy Footer to Read Display to Enhance Operator Productivity G H Adjustable viewing angle Water resistant
22 Technical Features: Tracer UC800 Adaptive Control Algorithm Keeps chiller running under normal or extreme conditions Variable Flow Compensation Compatible with Tracer Chiller Plant Control Open Protocols MODBUS RTU BACnet LONTalk 22 Insert Different Footer Communication Protocols available
23 UC800 Technical Features UC800 Detached Display Din rail mounting USB service port Smaller footprint Large Color Display Protocol Support LONtalk Comm4 MODBUS Slave BACnet MSTP Service Tool Tracer TU (Basic/Advanced) Processor 240Meg Hz (8X) 23
24 Adaptive Control : ensures chilled water production even in duty conditions close to the limit Trip Point Temperature Traditional Chiller Shut-off TRANE Adaptive Control Time The controllers internal algorithms enables corrective actions to be taken that keeps the chiller safely on-line make cold water where other chiller would trip off. 24 Insert Keep Footer the Chiller in Operation as much as possible
25 Tracer Adaptiview: Benefits summary Improves operator productivity Guarantee of continuous operation by utilizing industry-best Adaptive Control algorithms Optimize chiller operation Easier integration in Building Automation System thanks to open protocol flexibility 25 Insert An optimized Footer controller supporting user friendliness and ease of integration
26 CVGF Starters Various types of starters available: Mounted or not Low and Medium voltage 26
27 CVGF Starters Type of Starters available 380, 400, 415 V/50/3 3300, 6600 V/50/3 Starter type Unit mounted Remote Customer Supplied Starter type Remote Customer Supplied Star-Delta Closed transition Solid state x x x x x x Across the Line Auto transformer x x x x Primary Reactor x x 27
28 CVGF Low Voltage Starters Inrush Current Starter Type %LRA Advantages Star-Delta Solid State Equal reduction of torque & inrush current Price competitive Gradual inrush/ramp up No spike at transition Price slightly higher than Y- Disadvantages Only applicable up to 660 volts Spike at transition Higher level of service expense than Y- Higher inrush current then Y- Starting harmonics may be an issue Typical starting curves % LRA 28 Time (sec)
29 CVGF Medium Voltage Starters Inrush Current Starter Type %LRA Advantages Across-the-Line 100 Very price competitive Least Complex Lowest maintenance Disadvantages Draws highest inrush current at startup Primary Reactor 65 Good compromise between first cost and inrush current reduction More expensive than Across-the-Line Larger than Across-the Line Autotransformer 45 Almost equal reduction of torque and inrush current Lowest inrush current Most expensive Larger than Across-the Line Typical starting curves % LRA 29 Time (sec)
30 30 Good Sales!
Chiller Manufacturer should have been manufacturing chillers utilizing magnetic bearing, oil free technology for more than 10 years.
TURBOCOR COMPRESOR CHILLERS General Description Microprocessor controlled, water chiller using HFC 134a refrigerant, two stage centrifugal oil free variable speed compressor's and electronic expansion
More informationEngineered for flexibility and performance
Centrifugal Chillers 200 to 2700 tons Engineered for flexibility and performance Daikin McQuay Single Compressor Centrifugal Chillers A Life Cycle Return on Your Investment Centrifugal chillers are a significant
More informationHVAC Clinic. Helical Rotary & Centrifugal Water Chillers
HVAC Clinic Helical Rotary & Centrifugal Water Chillers Table Of Contents Introduction... 3 Chiller Types... 3 Chiller Components... 4 Refrigeration Cycle... 15 Application Considerations... 19 Introduction
More informationTechnical Development Program
Technical Development Program COMMERCIAL HVAC CHILLER EQUIPMENT Water-Cooled Chillers PRESENTED BY: Omar Rojas Sales Engineer Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7
More informationAs a standard, heat exchangers are provided with flange water connections (BS Standard Table E). All evaporator are supplied fully insulated.
NOMENCLATURE INTRODUCTION The HTT HWDX water-cooled chillers range is the latest addition to HTT s growing family of commercial products, featuring the most current technologies advances. The HWDX main
More informationCentrifugal Chiller. GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series
Centrifugal Chiller High Efficiency GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series Centrifugal Chiller High Efficiency Centrifugal Chiller HC-F-GFG-SSC Series (Super High Efficiency Type) HC-F-GXG-S
More information100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION
100 TON AIR-COOLED SCROLL PACKAGED SPECIFICATIONS Call us today! (800)341-4297 Trane Portable Packaged Air Conditioner units contain the best compressor technology available, in order to achieve the highest
More informationMidea VFD Centrifugal Chiller Technology
Midea VFD Centrifugal Chiller Technology Content Why VFD VFD centrifugal chiller technology Solution 2 HVAC major issues Energy conservation Global warming reduction 3 Why VFD No Compressor A/C Lower GWP
More informationRTHE Series R Helical Rotary Liquid Chiller Tons 60Hz
Features Product and Benefits Catalog RTHE Series R Helical Rotary Liquid Chiller 75-255 Tons 60Hz January 2015 RTHE-PRC002-EN Introduction To meet a wide range of applications in the 75~255 ton water-cooled
More informationGENERAL TABLE OF CONTENTS NOMENCLATURE DCLC D V
GENERAL From the beginning of 20 th Century, DB has been providing innovative solutions for the heating, air conditioning and refrigeration needs of its customers. Today s global company has a proud heritage
More informationAir conditioning 23XRV
High-Efficiency ChillerS with screw compressors Air conditioning Control CCN - Carrier Comfort Network Features The Evergreen range offers superior solutions with record capacities from 970 to 1880 kw,
More informationSENTRA Series Water Unit
SENTRA Series Water Unit Standard Unit: F to 0 F Process Fluid Temperatures* Optional High Temperature Configuration to 0 F Direct Injection Cooling 0 to kw Heaters to 7. HP Centrifugal Pumps (0-00 GPM)
More information.2 Section Waste Management and Disposal.
Issued 2005/06/01 Section 15624 Packaged Rotary Screw Water Chillers Page 1 of 5 PART 1 General 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3
More informationC. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.
SECTION 236426 - ROTARY-SCREW WATER CHILLERS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, water cooled or air cooled as scheduled, electric-motor-driven, rotary-screw water chillers
More informationCall us today! (800)
500 TON AIR-COOLED CHILLER PA-ACCTR-500 Call us today! (800)341-4297 The 500-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,
More informationCall us today! (800)
PA-ACCTR-200 Call us today! (800)341-4297 The 200-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable, efficient and quiet chiller
More informationWater-cooled Centrifugal Chiller
KMC Series Water-cooled Centrifugal Chiller 1795-4923kW(500RT-1400RT) R-134a Contents Nomenclature... 1 Unit features... 1 Computerized control... 3 General technical data... 4 Electrical data... 6 Dimension
More informationCall us today! (800)
150 TON AIR-COOLED CHILLER PA-ACCTR-150 Call us today! (800)341-4297 The 150-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,
More informationAPS Chiller Seminar. Don Brandt, CEM-AEE, BEAP-ASHRAE ASHRAE and IEEE Life Member 3/16/2017
APS Chiller Seminar Don Brandt, CEM-AEE, BEAP-ASHRAE ASHRAE and IEEE Life Member 3/16/2017 Agenda for today Refrigeration Cycle Chiller Types and Refrigerants Compressor Styles Chilled Water Pumping Systems
More informationWater-cooled chillers with High Speed Centrifugal Compressors
Water-cooled chillers with High Speed Centrifugal Compressors Refrigerant R134a 190-760 (395 to 2660 kw) Refrigerant R1234ze 135 G - 505 G (310 to 1820 kw) Table of Contents Introduction...3 Features and
More information30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models)
Temperature Control Units Water & Oil - 00 F Portable Chillers Air & Water-Cooled 0-70 F Central Chillers Air & Water-Cooled Packages & Modules 0-70 F Pump Tank Stations Chilled or Tower Water 00-00 gallons
More informationAgenda and Objectives
Agenda and Objectives Trane Engineers Newsletter Live Series Variable-Speed Drives (VSDs) and Their Effect On HVAC System Components Variable-speed drives (VSDs) can save energy, but the savings may not
More informationDunham Bush Air Cooled Screw Chiller AFVX B 6SR Series
Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series Type of Compressors Compressor Rotary Scroll Reciprocating Screw Centrifugal Air Cooled Chiller 77 ~ 329TR (270 ~ 1156 kw) ACDX Series 100 ~ 520TR
More informationWith the world-renowned SIGMA PROFILE
www.kaeser.com Rotary Screw Compressors BSD/CSD/CSDX T SFC Series With the world-renowned SIGMA PROFILE Free air delivery 0.87 to 16.10 m³/min, Pressures 5.5 to 15 11 What do you look for in a compressor
More informationYour Chiller Solution For Efficiency And Reliability. McQuay Dual Compressor Centrifugal Chillers 160 to 2500 Tons
Your Chiller Solution For Efficiency And Reliability McQuay Dual Compressor Centrifugal Chillers 160 to 2500 Tons McQuay Dual Compressor Centrifugal Chillers Superior part load efficiency, reliability
More informationProduct Catalog CTV-PRC001A-E4. Model CVGF Water-Cooled Liquid Chiller 400 to 1000 Tons ( kw) 50 and 60 Hz. March 2016
Product Catalog Model CVGF Water-Cooled Liquid Chiller 400 to 1000 Tons (1400 3510 kw) 50 and 60 Hz March 2016 CTV-PRC001A-E4 Introduction Introducing Trane s Model CVGF Centrifugal Water Chiller Introduction
More informationNew CGAF Air Cooled Scroll Chiller. New Air-Cooled Scroll Chiller CGAF
New CGAF New Air-Cooled Scroll Chiller CGAF New CGAF CGAF Air cooled Scroll Chiller 170 700 kw Cooling Only CXAF 150 700 kw Heat pump Coming soon 2 New addition to the Sintesis Family: Multiple technologies,
More information60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS
R Products That Perform...By People Who Care FORM NO: MS0455A WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS R134a HXWC SERIES 205 to 560 Tons 60Hz INTRODUCTION Dunham-Bush's HXWC water cooled
More information60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES
60 TON AIR-COOLED CHILLER PA-ACCTR-60 Call us today! (800)341-4297 The 60-Ton portable chiller package features a Trane CGAM chiller unit. Trane leads the industry in providing some of the most reliable,
More informationSubmittal. Date: September 04, Customer P.O. Number: Customer Project Number:
Submittal Prepared For: All Bidders Sold To: Date: September 04, 2012 Customer P.O. Number: Customer Project Number: Job Number: Job Name: DCS 12473 80 Ton Chiller Dept of Wildlife 1801 N Lincoln OKLAHOMA
More informationChapter-8 Capacity Control of Refrigeration Systems
Chapter-8 Capacity Control of Refrigeration Systems Chapter-8 Capacity Control of Refrigeration Systems ၈.၁ Compressor Control Chiller Control and Chilled Water Plant Control Refrigeration system control
More informationB. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).
Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage
More informationCutting Edge Compressor Technology
CHILLER MODULES Cutting Edge Compressor Technology MagLev ; magnetic levitation Oil Free design Quieter than typical background noise Soft start; pulls only 2 amps at 460V Superior part load efficiency
More informationAir-cooled Screw Chillers Model RTAF G Process
Air-cooled Screw Chillers Model RTAF G Process Near 0 GWP (
More informationPresented By: John Dolan, P.E.
Variable Speed Compressor Technologies Presented By: John Dolan, P.E. President - Thermosystems, Inc. BS in Mechanical Engineering from UIUC 29 years HVAC Equipment Application Experience jdolan@thermohvac.com
More informationInnovation for a Better & Greener Future
Innovation for a Better & Greener Future Comprehensive range of Water Cooled Variable Speed Centrifugal Chillers with Magnetic Bearing Compressors Kirloskar Chillers, a future-focused organisation, has
More informationCentrifugal Compressor Water Chillers Catalog 605 Models WSC, WDC, WCC, HSC
Centrifugal Compressor Water Chillers Catalog 605 Models WSC, WDC, WCC, HSC Engineered for flexibility and performance Cutaway view of McQuay Model CE 063 Compressor, Nominal 250 Tons MicroTech II Controller,
More information(2) 325 tpd York Chlorine Liquefier Systems
(2) 325 tpd York Chlorine Liquefier Systems The liquefier is a split bundle and serves as both the primary liquefier and the secondary liquefier. The total for each York system is 325 tons liquid Cl2,
More informationLeadership, Innovation, Advanced Technology Synergise Here!
Cooling Synergies Leadership, Innovation, Advanced Technology Synergise Here! 125 years of Engineering Innovation Kirloskar Chillers is proud to be a part of 125 years old Kirloskar Group. The diversified
More informationHow to Cut Chiller Energy Costs by 30%
How to Cut Chiller Energy Costs by 30% Pre-packaged retrofit cuts centrifugal compressor chiller energy costs by 30% while reducing required maintenance and extending operating life at Duke Realty Corporation
More informationEPCE00-10B. Powerful. air cooled. Hydronic systems EUWA*40-200K(A)X
EPCE00-10B Powerful air cooled Hydronic systems EUWA*40-200K(A)X Development Environment Technology 2 Daikin s pre-eminent position in air conditioning and chiller production has been built on over 70
More information19DV Back-to-Back Centrifugal Liquid Chiller with PUREtec TM Refrigerant and Greenspeed TM Intelligence
19DV Back-to-Back Centrifugal Liquid Chiller with PUREtec TM Refrigerant and Greenspeed TM Intelligence 19DV Two-stage: 600-800Ton (Air-conditioning Low voltage VFD) Turn To The Experts Inheriting a rich
More informationXStream Water-cooled screw chillers and Water/Water Heat pumps
XStream Water-cooled screw chillers and Water/Water Heat pumps Models 275 515 (935 to 1860 kw) 330 640 (1155 to 2220 kw) RLC-PRC058B-GB Table of Contents Introduction...4 Feature and benefits...5 Base
More informationEconomic Perspectives from Chiller Design to Operation. Ir K.T. Cheuk 1 Dec 2017
Economic Perspectives from Chiller Design to Operation Ir K.T. Cheuk 1 Dec 2017 2 Design x Construction Building Operation Design x Construction Acoustic Treatment Electrical Installation High Efficiency
More informationWicomico County Purchasing 125 N. Division St. Room B-3 Salisbury, MD Ph Fax Addendum # 1
Addendum No. 1 Wicomico County Purchasing 125 N. Division St. Room B-3 Salisbury, MD 21801 Ph. 410-548-4805 Fax 410-334-3130 Addendum # 1 Date: 3/11/2016 Bid: Chiller Removal and Installation A Pre-Bid
More informationTrailblazer air cooled scroll chillers
Trailblazer air cooled scroll chillers Changing the way you think about air cooled chillers 30 to 240 tons with Variable Speed Condenser Fan Technology People and ideas you can trust. Changing the way
More informationFeaturing Ozone-safe HFC134a. Hitachi Centrifugal Chillers. NEW GXG-S Series GSG-S Series Debut
Featuring Ozone-safe HFC134a Hitachi Centrifugal Chillers NEW GXG-S Series GSG-S Series Debut Centrifugal Chiller New GXG-S, GSG-S Series Debut High-efficiency New series Centrifugal Chillers that use
More informationAC SYSTEM CONFIGURATION- CENTRAL CHILLER PLANT
AC SYSTEM CONFIGURATION- CENTRAL CHILLER PLANT Central Chiller Plant (with Cooling Tower and Chilled Water distribution) The other AC configuration is called a Chilled Water or Larger Cooler system. It
More informationEN aquatech.piovan.com
EN aquatech.piovan.com Refrigeration Technologies: scroll-compressor chillers The scroll compressor is the most suitable component for the small and medium duty requirements in the industrial applications.
More informationScrew Compressors HSD SERIES. Capacities from: 816 to 3002 cfm Pressures from: 80 to 217 psig
Screw Compressors HSD SERIES Capacities from: 816 to 3002 cfm Pressures from: 80 to 217 psig What do you expect from a large compressor system? All compressed air users need a reliable air system and want
More informationSmardt Oil-Free Chillers
Smardt Oil-Free Chillers Company History in Brief Turbocor compressor invented in Australia in 1993 Turbocor was relocated to Montreal in 1999 Danfoss forms 50/50 partnership in 2004 Smardt was founded
More informationGlobal Series Screw Air Compressors Life source of industries
Global Series Screw Air Compressors Life source of industries 125-200 HP series Global Series Elgi, established in 1960, designs and manufactures a wide range of compressors. The company has gained its
More informationInstallation Operation Maintenance
Installation Operation Maintenance RTAF SE/HE/XE/HSS/HSE Air-cooled Helical-rotary chillers 300-1600 kw Sintesis chillers are part of the Ingersoll Rand EcoWise portfolio of products that are designed
More informationSECTION CENTRIFUGAL WATER CHILLERS
PART 1 GENERAL 1.01 SECTION INCLUDES A. Chiller package. B. Charge of refrigerant and oil. C. Controls and control connections. D. Chilled water connections. E. Condenser water connections. F. Variable
More informationA Career that will take you to heights you never imagined!
Air-Conditioning Automation systems Boiler systems Chilled water systems Commissioning Electrical Electronics Graphic design Green technologies Information technology Networking Programing Refrigeration
More informationACMVTECH HIGH EFFICIENCY UNITARY AHU
HIGH EFFICIENY UNITARY AHU 50 / 60 Hz R-134A, R407c R-407F, R-410A ACMVTECH HIGH EFFICIENCY UNITARY AHU WATER COOLED CONDENSERS VARIABLE and CONSTANT SPEED VSD FANS ; VSD COMPRESSORS ACMCVTECH UNITARY
More informationGeneSys. Air-Cooled Screw Compressor Chillers. Catalog
Catalog Cat AGS-2 GeneSys Air-Cooled Screw Compressor Chillers Models AGS 120C to AGS 210C 110 to 210 Tons, 420 to 740 kw Packaged and with Remote Evaporator R-134a, 60 Hz Engineered for flexibility and
More informationProduct Data. Features/Benefits ComfortLink control
Product Data 30GTN,GTR Air-Cooled Reciprocating Liquid Chillers with ComfortLink Controls 50/60 Hz Nominal Capacities: 60 to 410 Tons 205 to 1445 kw Features/Benefits ComfortLink control Your link to a
More informationDate: August 21, Proposal Number: G Engineer: Payment Terms: Net 30 Days
Proposal Trane A Division of American Standard Inc. Prepared For: John Weston Desmet Ballestra Job Name: LAUER1 Biodiesel Chiller Pennsylvania Date: August 21, 2006 Proposal Number: G1-95502-1 Engineer:
More informationOptions Guide. Air-cooled Liquid Chillers with Screw compressors. Models RTAC 120 to 400 RLC-PRB030-E4
Options Guide Air-cooled Liquid Chillers with Screw compressors Models RTAC 120 to 400 MAY 2012 1 Table Of Contents 1. RANGE OVERVIEW... 4 1.1. RTAC RANGE... 4 2. OPERATING MAP... 5 2.1. STANDARD EFFICIENCY...
More informationDENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION REFRIGERATION
PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. General: 1. Design and specify refrigeration systems and equipment in accordance with "Energy Conservation Standards" stipulated in Section 15010, Basic
More informationGlobal Series Screw Air Compressors Life source of industries HP
Global Series Screw Air Compressors Life source of industries - 200 HP ELGi, established in 1960, designs and manufactures a wide range of compressors. The company has gained its reputation for design
More informationXStream Water-cooled screw chillers and Water/Water Heat pumps
XStream Water-cooled screw chillers and Water/Water Heat pumps Refrigerant R134a Model 275-515 (940 to 1860 kw) Model 330 - K00 (1140 to 3670 kw) RLC-PRC058C-GB Table of Contents Introduction...3 Feature
More informationMicroTech Series-200 Flooded Screw Chiller
Open Protocol Data Infomation Packet Version 1.0 Group: Controls Date: February 1997 MicroTech Series-200 Flooded Screw Chiller Open Protocol Data Communications 2002 McQuay International - C O N F I D
More informationEarthWise CenTraVac Water-Cooled Liquid Chillers
Product Catalog EarthWise CenTraVac Water-Cooled Liquid Chillers 170 3950 Tons, 50 and 60 Hz Tonnage Ranges By CenTraVac Model Number CVHE Three-Stage Single Compressor CenTraVac 50/60 Hz 170 500 CVHF
More informationFans and Pumps I. Dr. Sam C. M. Hui Department of Mechanical Engineering The University of Hong Kong
MEBS6008 Environmental Services II http://www.mech.hku.hk/bse/mebs6008/ Fans and Pumps I Dr. Sam C. M. Hui Department of Mechanical Engineering The University of Hong Kong E-mail: cmhui@hku.hk Sep 2012
More informationA. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.
15682 CENTRIFUGAL WATER CHILLERS ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 236416 An optional
More informationWater-Cooled Modular Chillers. Product Data Catalog. Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X
Product Data Catalog Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X Variable Speed Total Access Modules MS010W, MS020W, MS030W, MS050W MS010V, MS020V,
More informationOACS Outdoor Air-Cooled Central Chillers
OACS Outdoor Air-Cooled Central Chillers Proudly Made In The USA since 1977 A Complete Central Chiller System Complete Central Chiller system with Integrated Reservoir and Pump all mounted on a single
More informationCentrifugal Compressor Water Chillers THE DISTINCTION SERIES
Product Manual PM WSCWDC-2 Centrifugal Compressor Water Chillers THE DISTINCTION SERIES Model WSC, Single Compressor, Cooling Model WDC, Dual Compressor, Cooling Model HSC, Single Compressor Heat Recovery
More informationSECTION REFRIGERATION. 1. Reciprocating Compressors (Hermetic). 2. Reciprocating Compressors (Open Drive). 3. Water Cooled Condensing Units.
SECTION 15650 REFRIGERATION PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Reciprocating Compressors (Hermetic). 2. Reciprocating Compressors (Open Drive). 3. Water Cooled Condensing Units. 4. Air
More informationInstallation Manual. Gear-Driven Centrifugal Water- Cooled Liquid Chillers CVGF-SVN02B-E4 X
Installation Manual Gear-Driven Centrifugal Water- Cooled Liquid Chillers Unit Model CVGF 400-1000 Ton Units (50 and 60 Hz) X39640686020 Warnings and Cautions NOTICE: Warnings and Cautions appear at appropriate
More information30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw
AIR-COOLED LIQUID CHILLER REVERSIBLE AIR-TO-WATER HEAT PUMP PRO-DIALOG PLUS 30RB/RQ 039S-60S Refrigerant HFC-40A Nominal cooling capacity 40-58 kw Nominal heating capacity 4-59 kw The new generation of
More informationForm No: MS0454A. Products That Perform...By People Who Care. Screw Compressor Air Cooled Flooded Chillers. HXAC Series. R134a. 60 Hz.
R Products That Perform...By People Who Care Form No: MS0454A Screw Compressor Air Cooled Flooded Chillers R134a HXAC Series 60 Hz 70 to 200 Tons TABLE OF CONTENT DESCRIPTION PAGE NO Nomenclature...2 Specifications...3
More informationL07 L22 (10 30 HP) FIXED-SPEED ROTARY SCREW COMPRESSORS. L Series
L07 L22 (10 30 HP) FIXED-SPEED ROTARY SCREW COMPRESSORS L Series Advanced Technology Inspired Simplicity A Better Approach Gardner Denver has a long history of manufacturing compressed air equipment. With
More informationCentrifugal Compressor Water Chillers
Centrifugal Compressor Water Chillers Models WSC, WDC, WCC, HSC Includes Higher Voltage (10/11kV) WDC/WCC models People and ideas you can trust. Catalog 605-3 Contents Contents..................................
More informationSECTION CHILLERS
SECTION 15650 PART I - GENERAL 1.01 WORK INCLUDED A. Extent of work shall be as indicated on Drawings and provisions of this section, including schedules and equipment lists associated with either Drawings
More informationWATER-COOLED CHILLERS WITH ROTARY SCREW COMPRESSORS
Form No: MS0434A WATER-COOLED CHILLERS WITH ROTARY SCREW COMPRESSORS EXTENDED CAPACITY RANGE 1001 to 1850 tons 50 Hz Features Uses HCFC-22 and compatible with HFC refrigerants Advanced microcomputer with
More informationCopy Right By: Thomas T.S. Wan
Chapter 23 Motor and Starter Copy Right By: Thomas T.S. Wan 温到祥著 Sept. 3, 2008 All rights reserved Electric Motors All the motors are to be designed and constructed in accordance with NEMA code. Electric
More informationWater Cooled Centrifugal Chiller HTS/HTC
Water Cooled Centrifugal Chiller HTS/HTC Cooling capacity: 300-2600 Tons (1055.0kW-9142.0kW) HFC-134a Refrigerant MANAGEMENT SYSTEM CNAS C002-M MANAGEMENT SYSTEM CNAS C002-M MANAGEMENT SYSTEM CNAS C002-M
More informationWIND Technical Description
Termomeccanica Group Company WIND Technical Description OIL-INJECTED ROTARY SCREW COMPRESSORS BELT DRIVEN Capacity from 360 to 2000 l/m Pressure from 8 to 15 bar Power from 2,2 to 15 kw 2 l Adicomp S.r.l.
More informationWater-Cooled Screw Compressor Chillers
Catalog Cat WGS Water-Cooled Screw Compressor Chillers WGS 130AW To WGS 190AW, Packaged Water-Cooled Chiller WGS 130AA To WGS 190AA, Chiller with Remote Condenser 120 to 200 Tons, 420 to 700 kw R-134A,
More informationHorizontal Split Case Pumps Type U
Horizontal Split Case Pumps Type U 7.1 7.2 Stage U Type Pumps Features: Axially Split Case Design Range from 20M 3 /Hr to 600M 3 /Hr Two Stage Pump Single Suction Twin Volute Casing Design Closed type
More informationMTW Series Modular Oil Free Centrifugal Chillers
TW Series odular Oil Free Centrifugal Chillers Cooling Capacity:300-2890kW odular Chiller agnetic Levitating Centrifugal Compressor Stainless Steel PHE Refrigerant R134A ax. COP: 12w/w TW Series odular
More informationSECTION PACKAGED WATER CHILLERS
SECTION 23 64 00 PACKAGED WATER CHILLERS SPEC WRITER NOTES: 1. Delete between //----// if not applicable to project. Also delete any other item or paragraph not applicable in the section and renumber the
More informationMicroTech Series 200 Centrifugal Chiller
Protocol Data Information Packet Version 2.2 Group: Controls Date: March 1999 MicroTech Series 200 Centrifugal Chiller Data Communications Packet for Protocol 2002 McQuay International Revision History
More informationMagnetic Bearing Technology: Achievements in Higher Efficiency
Magnetic Bearing Technology: Achievements in Higher Efficiency Magnetic Bearing Compressor 100% Oil Freeeliminates oil system maintenance costs. R134a Refrigerantmeets Montreal protocol and is not subject
More informationECO-ANT21 Corporation
ANT Turbo blower - Summary Turbo Blower is a device generating compressed air using an applied air bearing, impeller, high speed motor, inverter and controller connected to a robust centrifugal turbine
More informationOpen Protocol Data Communications
MicroTech Series-100 Centrifugal Chiller Open Protocol Data Communications Information Packet Version 3.2 April, 1996 - C O N F I D E N T I A L - This Document may not be copied or reproduced in any way
More information30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw
Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: 40-158 kw Nominal heating capacity: 41-159 kw Carrier China Carrier Corporation is a subsidiary of the United Technologies
More informationSales and Engineering Data Sheet ED
Sales and Engineering Data Sheet ED 15121-7 Group: Controls Part Number: ED 15121 Date: July 2017 MicroTech III Chiller Unit Controller Protocol Information Modbus Networks ANSI/ASHRAE 135-2004, BACnet
More informationINVERTER SCROLL. LG Electronics Distributed by. Copyright 2017 LG Electronics. All rights reserved.
LG Electronics http://www.lg.com http://partner.lge.com Distributed by Copyright 2017 LG Electronics. All rights reserved. FEATURES & BENEFITS High Efficient Inverter Technologies EER 2.65 / COP 3.2 /
More informationUpdate Dedicated Heat Recovery Chiller Technology. Don Frye. Gulf South
3/5/2018 1 Update Dedicated Heat Recovery Chiller Technology Don Frye Gulf South Good design is an intentional act Begin with the end in mind Basic Bldg Tenants IAQ (low VOC & CO 2 ) Controlled Temp &
More informationTECHNICAL. Series 18. Pump Packages
TECHNICAL S Y S T E M S Series 18 Pump Packages Series 18 Pump Packages Standard Features Close-coupled, end-suction, centrifugal pumps Mounted and wired pump starters Hand-Off-Auto switch for each pump
More informationFeaturing Ozone-safe HFC134a. Hitachi Centrifugal Chillers NEW. GXG-S Series GSG-S Series. Debut
Featuring Ozone-safe HFC134a Hitachi Centrifugal Chillers NEW GXG-S Series GSG-S Series Debut Centrifugal Chiller New GXG-S, GSG-S Series Debut High-efficiency New series Centrifugal Chillers that use
More informationSLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual
u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications
More information30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG +
Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG + Quality Management Systems 30RBY/RQY 017-033 Nominal cooling capacity 15-33 kw Nominal heating capacity 17-31 kw The new
More informationAir-Cooled Screw Compressor Chillers
Catalog Cat AGSD-1 Air-Cooled Screw Compressor Chillers Models AGS 225D to AGS 450D 210 to 450 Tons, 740 to 1580 kw Packaged or with Remote Evaporator or Chilled Water Pump Package R-134a, Hz Engineered
More informationMagnitude Magnetic Bearing Centrifugal Chillers. Model WME 400 to 1500 Tons (1400 to 5300 kw) HFC-134a Refrigerant. Catalog 604-8
Magnitude Magnetic Bearing Centrifugal Chillers Model WME 400 to 1500 Tons (1400 to 5300 kw) HFC-134a Refrigerant Catalog 604-8 Table of Contents Table of Contents Introduction.... 3 Technology That Just
More informationTorad Rotary Spool Compressor
Torad Rotary Spool Compressor Communication White Paper By: Torad Engineering, LLC Cumming, Georgia USA Torad Rotary Spool Compressor Introduction: The rotary spool compressor shares various attributes
More information