1 Heating ontrols For further information, please contact your appropriate Sales Office The perfect commercial partnership UK Northern team: Telephone: Fax: Southern team: Telephone: Fax: Western team: Telephone: Fax: Eastern team: Telephone: Fax: Pegler is an expert in the production of Taps, Mixers and Valve products. It boasts an unrivalled track record for integrity, quality, reliability and innovation. Yorkshire is a specialist in the production of metal plumbing and heating fittings. It has an established reputation for manufacturing quality products. EXPORT Telephone: +44 (0) Fax: +44 (0) export@pegler.co.uk Technical helpline: LUXURY TP SOLUTIONS INTEGRL SOLDER RING FITTINGS THE PUSH-FIT JOINTING SYSTEM Pegler Limited, St. atherine s venue, Doncaster, South Yorkshire, DN4 8DF, England. HETING ONTROLS VLVES ND FITTINGS THE PRESS-FIT JOINTING SYSTEM Registered ompany No Place of Registration: England ll brand names and logo styles are registered trademarks. Maintaining a policy of continual product development, Pegler Ltd reserve the right to change specifications, design and materials of products listed in this databook without prior notice. LIT.REF: UTILITY TP SOLUTIONS OMPRESSION FITTINGS END FEED FITTINGS OMMERIL VLVES

2 Heating ontrols

3 HW TWIE LL DY ONT OFF MON ON OOST DV W TWIE LL DY PM ONT OFF OFF OOST DV irculating Pump Model T5 TF110 IP 44 IE lass H 10 bar Max S EN S EN v~ Setting urrent() Power (W) Hz μF is starting by screw loosening vent the 3 TERRIER II 3 TERRIER II 3 TERRIER II 3 TERRIER II For more information on Pegler Yorkshire visit The range. ll hot water control... Established in 1899 and proud of its time-honoured principles of quality, innovation and customer service, Pegler is respected the world over as one of the leading manufacturers of plumbing and heating products. Out of this great tradition has come the unrivalled Terrier range of heating controls, radiator valves, circulating pumps and accessories. Terrier quality and pedigree Terrier radiator valves have long been the most trusted and respected in the industry for quality, design, reliability and overall value for money attributes to be found in every product in the comprehensive Terrier heating range. Robust construction under the most stringent quality control conditions assures a long working life. Pegler investment in advanced manufacturing techniques to complement the traditional skills of the workforce has achieved S EN ISO 9002 (S 5750) accreditation. Where appropriate there is compliance with kitemark ritish Standards or the European norm (S , EN 215), with independent testing and certification. Every Terrier product is made to perform better and to last longer by any standards, the one true measure of value for money. Terrier innovation Pick up any item from the Terrier heating range and the superior quality and extra features are immediately apparent. ttractive styling. Thoughtful and flexible design. lear control markings. Quiet operation. Easy installation and maintenance Terrier service s with all Pegler products, the Terrier range is supported by outstanding customer service. Friendly and helpful telephone response. omputerised sales ordering and distribution. Full installation instructions with every Terrier product. ll the technical support and advice you could need from Pegler s expert team and dedicated helpline. TYPIL ZONE VLVE SYSTEM Ensure pump vented before 2 HETING QULITY YOU N TRUST

4 round heating and Pegler heating products The complete range The Pegler heating package is continually developing and evolving to provide ever better and more cost-effective solutions to customers needs. Terrier heating controls, radiator valves, circulating pumps and accessories are designed principally for the domestic market but they are also suitable for light commercial applications such as healthcare centres and offices. ontents Page Single hannel and Two hannel Digital Programmers 4/5 Three hannel Digital Programmer 6 Single hannel and Two hannel Electro-mechanical Programmers 7 Room Thermostats 8 Frost Thermostat 9 ylinder Thermostat 10 Wiring entre 11 Zone and Mid-position Valves 12/13 Zone and Mid-position ontrol Packs 14/15/16 The Terrier range comprises stylish, state-of-the-art heating controls including manual and thermostatic valves for 8, 10 and 15mm pipe sizes plus 1 /2" iron connection for iron or steel pipe light commercial systems. ombi ontrol Pack 17 Wiring Diagrams 18/19 Terrier Manual Radiator Valves 20/21 Terrier Thermostatic Radiator Valves 22/23 Terrier Decorative Thermostatic and Manual Radiator Valves 24/25 Terrier Decorative Manual Radiator Valves 26/27 Terrier Differential Pressure ypass Valves 28/29 Terrier Domestic irculating Pumps 30 Terrier irculating Pump Isolating Valves 31 Ventair ir Separators 32 Pegler Website Information 33/34/35 HETING QULITY YOU N TRUST 3

5 Single hannel & Two hannel Programmers TP1 Single hannel Programmer TP2 Two hannel Programmer Easy to install and easy to use, these very reliable Terrier programmers are designed to blend in with virtually any room setting. Single-channel programmers are intended for central heating only or combination boilers, and two-channel for central heating and stored hot water systems. Simple to set up, both programmers have versatile settings with up to 3 timed periods per day for each day of the week (for both hot water and heating in the two-channel programmer) and the option of DVNE and OOST features. These give users the flexibility to vary their timed periods to suit individual needs. nother very practical feature of both programmers is an industry-standard 6-pin backplate. This makes it a simple matter to fit either from new or when replacing a similar existing model. SINGLE & TWO HNNEL PROGRMMERS FETURES Up to 3 on-off periods per day maximum flexibility when setting up programmes Different settings for every day of the week. hoice of Timed, II Day or ontinuous easy to set up and use opy button facility enables user to copy programmes from one day to another at the touch of a button Large easy to read LD display simple to see programme status and how to set up programmer Industry-standard 6-pin wallplate replaces many other competitor models dvance button and 1, 2 or 3hrs boost to existing programmes extends the flexibility of existing programmes without the need to alter them aters for gravity hot water systems with removable link can be used on older systems as replacement for early programmer models (TP2 model) Independent timing for heating and hot water (TP2) energy saving and convenient, meets Part L of the uilding Regulations Elegantly styled to fit in with any surroundings 4 HETING QULITY YOU N TRUST

6 Wiring Detail TP1 TP2 N L v OMM OFF ON 50Hz N L v 50Hz HW OFF H OFF Dimensions (mm) HW ON H ON TP1 TP1 & TP2 ontact type micro disconnection Voltage rating 230v, 50Hz urrent rating 3(1) Double insulated Electrical Protection lass IP30 lock operation 12 hour am/pm Display liquid crystal attery reserve 1O months minimum Operating temperature range 0º to 40º TP2 Model Single Two 7 Order hannel hannel Day ode TP TP Model TP1 & TP HETING QULITY YOU N TRUST 5

7 Three hannel Programmer TP3 Three hannel Programmer This offers the same flexibility and simple operation of Terrier single-channel and two-channel programmers, but the additional heating channel allows for control of a further heating zone in larger properties, as required by Part L1 of the uilding Regulations. Styled to match the rest of the programmer range and to look perfectly at home in a wide variety of room settings, it features a soft-touch key pad for easy use and programming. ontact type micro disconnection Voltage rating 230v, 50Hz urrent rating 3(1) Double insulated Electrical Protection lass IP30 lock operation 12 hour am/pm Display liquid crystal attery reserve 1O months minimum Operating temperature range 0º to 40º THREE HNNEL PROGRMMER FETURES Up to 3 on-off periods per day maximum flexibility when setting up programmes Different settings for every day of the week. hoice of Timed, II Day or ontinuous easy to set up and use 32 day holiday function opy button facility enables user to copy programmes from one day to another at the touch of a button Large easy to read LD display simple to see programme status and how to set up programmer Easy to wire 9 pin backplate dvance button and 1 or 2 hour boost to existing programmes extends the flexibility of existing programmes without the need to alter them Independent timing for each heating and hot water zone energy saving and convenient, meets Part L1 of the uilding Regulations Elegantly styled to fit in with any surroundings Dimensions (mm) Model TP Wiring Detail Model Single Two Three 7 Order hannel hannel hannel Day ode TP N L v 50Hz ON OFF H ZONE 1 ON OFF H ZONE 2 ON OFF HW 6 HETING QULITY YOU N TRUST

8 Single hannel and Two hannel Electro-mechanical Programmers TMP1 Single hannel Electro-mechanical Programmer PROGRMMER FETURES Permanent ON/OFF ON all day ON/OFF twice a day Suitable for combi boiler systems and heating only systems (TMP1) Suitable for pumped systems and gravity HW (TMP2) Single element heating control (TMP1) TMP2 Two hannel Electro-mechanical Programmer The use of a simple dial and switches makes Terrier (TMP) electro-mechanical programmers extremely easy to use. The TMP1 is a simple-to-operate and effective single channel programmer which is suitable for use with combi boiler systems, warm air systems and applications where single zone control is required. The TMP2 programmer offers maximum flexibility for both the heating and hot water circuits, with 16 programmes available for fully pumped systems, including separate programming of heating and hot water, and 10 programmes for gravity hot water/pumped central heating systems. TMP1 - Single circuit 13(6) 230V c TMP2 - Two circuit 13(6) 230V c ontact Type: Micro disconnect Voltage Rating: 230V, 50Hz Double Insulated Enclosure Protection: IP20 9 pin wall fixing plate Maximum Operating Temperature: 55 º Dimensions (mm) Model TMP TMP Wiring Detail TMP1 TMP2 Model Order ode TMP TMP HETING QULITY YOU N TRUST 7

9 Room Thermostats ROOM THERMOSTT FETURES Range from 5º to 30º wide operating range for maximum flexibility Temperature differential 0.4º with built-in accelerator heater close range to ensure maximum user comfort Temperature differential 0.6º without built-in accelerator heater can be connected in place of older two-wire room thermostats Range limiting stops for restriction of operation in nursing homes etc Large easy grip dial with easy to read temperature markings easy to set and simple to use Styled in white to suit any surroundings TRT1WL model with built in neon light shows the end user that the thermostat is calling for heat Dimensions (mm) TRT1 Room Thermostat Elegantly styled, Terrier room thermostats ensure accurate temperature control. The benefits: maximum comfort combined with improved energy efficiency. The tried and tested thermostatic mechanism, which is quiet in operation, can replace older thermostats by using a 2-wire as well as a modern 3-wire connection. TRT1WL Room Thermostat Model TRT1/TRT1WL Range from 5º to 30º Range limiting stops ontact rating 10(3) Temperature differential 0.4º with accelerator connected, 0.6º with accelerator disconnected Voltage rating 230v, 50 Hz Electrical Protection lass II IP30 ontact configuration SPDT Wiring Detail L 230v ac 50Hz Double Pole Isolator Fuse ROOM THERMOSTT N Model Order ode Time ontrol Heating Load L N TRT ooling Load L N TRT1WL TRT1WL models only 8 HETING QULITY YOU N TRUST

10 Frost Thermostats FROST THERMOSTT FETURES Operating range from 5º to 10º ensures sufficient protection above freezing point Temperature differential 0.6º without built-in accelerator heater accurate control with only simple two-wire connection oncealed operating knob with tool access tamper resistant frost settings Styled to suit any surroundings TFT1 Frost Thermostat Dimensions (mm) Highly recommended where there is exposed waterfilled system pipework or components, Terrier frost thermostats require only a 2-wire connection and automatically operate the pump and boiler to prevent freezing up or to provide background heating even if the other system controls are not calling for heat. concealed dial prevents accidental tampering with the setting. Model TFT Operating range from 5º to 10º Temperature differential 0.6º ontact rating 10(3) Voltage rating 230v, 50 Hz Electrical Protection lass II IP30 ontact configuration SPST Wiring Detail L 230v ac 50Hz Double Pole Isolator FROST THERMOSTT Fuse 3 1 N Model Order ode Time ontrol Heating Load L N TFT HETING QULITY YOU N TRUST 9

11 ylinder Thermostat YLINDER THERMOSTT FETURES Range from 30º to 90º covers low and high temperature water storage applications Temperature differential 5º to 10º prevents unnecessary boiler cycling Large easy grip dial with easy to read temperature markings easy to set and simple to use TT1 ylinder Thermostat Dimensions (mm) Terrier cylinder thermostats maintain the temperature of stored water at a safe level, but are adjustable where higher temperatures are required. Secured by means of the nylon strap provided, they fit in cylinders which have a standard 25mm foam insulation layer. Of robust construction for reliability and a long working life, Terrier cylinder thermostats have a wide temperature differential to prevent unnecessary boiler cycling. Model TT Range from 30º to 90º ontact rating 16(3) Temperature differential 5º to 10º Voltage rating 230v, 50 Hz Electrical Protection lass II IP43 Securing strap and clip nylon ontact configuration SPDT Wiring Detail L 230v ac 50Hz Double Pole Isolator Fuse YLINDER THERMOSTT N Heating Load Model Order ode Time ontrol L N ooling Load L N TT HETING QULITY YOU N TRUST

12 Wiring entre TW1 Wiring entre This purpose-designed junction box ensures that Terrier heating controls are connected together for correct operation. It has a demountable 10-way terminal block with access below the block for greater ease of connection. The Terrier wiring centre also incorporates a mains cable clamp and surface knockouts to give all-round access for both surface wiring and flexible cables. WIRING ENTRE FETURES Flat baseplate design, with raised terminal block easy all-round access for making connections to terminal block 10-way terminal block with wiring access right underneath the terminal block - for greater flexibility oth rear and all-round surface wiring access with easy-to-break wiring knockouts very flexible - can accommodate almost any arrangement of system cabling uilt-in mains cable clamp and cable tie points additional electrical safety when making flexible cable connections to wiring centre Two-gang box size compact, simple and convenient 10 x 2-way terminal block Voltage rating 230v, 50 Hz urrent rating cable access knockouts around edge, 2 rear access knockouts 1 x mains cable clamp and 6 x cable tie points Dimensions (mm) Model Order ode TW Model TW HETING QULITY YOU N TRUST 11

13 Zone and Mid-position Valves TZV Zone Valve (ompression) TZV Zone Valve (Female Iron) The heart of a modern heating controls system, Terrier motorised valves are extremely robust, reliable, quiet in operation and interchangeable with other makes. vailable in 22mm and 28mm compression fitting and 3 /4 and 1 female iron sizes, and 2-port zone valve and 3-port midposition valves, they cater for the widest possible range of applications for domestic and light commercial premises. For easy maintenance the actuator can be removed separately without draining the system down, and superior Terrier construction ensures durability in the cylinder cupboard location. oth zone and mid-position valves have built-in self-cleaning shoes for maximum working life. Model Size Order ode TZV22 22mm ZONE ND MID-POSITION VLVE FETURES hoice of two-port and zone valves in 22mm or 28mm copper compression connections and 3 4 and 1 female iron connections designed to replace most existing valve bodies, for use in new or replacement applications Removable actuator with 1m flex in industry standard core colours easy to change without draining down the system Spring return actuators with built-in electrical interlock auxiliary switch meets Part L1 of the uilding Regulations TZV & TMPV Models Maximum ambient temperature 52º Water temperature 2º to 93º Voltage rating 230v, 50 Hz Motor rating 6W nominal Max pressure 10bar opper compression and female iron connections available TZV28 28mm TZV TZV TMPV22 22mm TMPV28 28mm TMPV TMPV HETING QULITY YOU N TRUST

14 TMPV Mid-position Valve (ompression) TMPV Mid-position Valve (Female Iron) Dimensions (mm) Dimensions (mm) ompression connections Threaded connections D D D D D 1 2 Model D 1 TZV22/TZV TMPV22/TMPV Model D 3 TZV 3 4/TZV TMPV 3 4/TMPV Wiring Detail TZV22 / TZV28 ZONE VLVES TZV 3 4 / TZV1 ZONE VLVES rown Grey Orange H / HW DEMND PERMNENT LIVE HETING LOD NEUTRL lue Wiring Detail TMPV22 / TMPV28 MID POSITION VLVES TMPV 3 4 / TMPV1 MID POSITION VLVES White H DEMND Grey HW STISFIED HW DEMND / HETING LOD NEUTRL Orange lue See page 18/19 for wiring diagrams HETING QULITY YOU N TRUST 13

15 Zone ontrol Packs including Electronic Programmer The Terrier ontrol Pack incorporates all the elements required for central heating and hot water control in one box. For individual room temperature control we recommend Terrier thermostatic and manual radiator valves. The Terrier control packs come complete with instructions for installing the individual controls and then all together to make installation as easy as possible. For further advice on Terrier heating control packs or for their application, please contact our Technical Service Team on For product specification please refer to relevant page. Product Page TZV Zone Valve 12 & 13 TZV Zone Valves x 2 TW1 Wiring entre TP2 Programmer TRT1 Room Thermostat TT1 ylinder Thermostat Model Description Order ode TP2ZV22 22mm Zone Pack TP2ZV28 28mm Zone Pack TW1 Wiring entre 11 TP2 Programmer 4 & 5 TT1 ylinder Thermostat 10 TRT1 Room Thermostat 8 See page 18/19 for wiring diagrams PROGRMMER WIRING ENTRE TYPIL ZONE VLVE SYSTEM THERMOSTTI RDITOR VLVE MNUL LOKSHIELD RDITOR VLVE ZONE VLVE ZONE VLVE YLINDER THERMOSTT ROOM THERMOSTT IRULTING PUMP DIFFERENTIL PRESSURE VLVE OILER 14 HETING QULITY YOU N TRUST

16 Mid-position ontrol Packs including Electronic Programmer The TP2MPV pack also incorporates the elements required for central heating and hot water control. The pack also includes the mid-position motorised valve available in 22mm and 28mm to give you extra flexibility. For individual room temperature control we recommend Terrier thermostatic and manual radiator valves. Packs come with complete installation instructions for installing individual items. For further advice on Terrier heating control packs or for their application, please contact our Technical Service Team on For product specification please refer to relevant page. TMPV Mid-position Valve TW1 Wiring entre TP2 Programmer TT1 ylinder Thermostat TRT1 Room Thermostat Model Description Order ode TP2MPV22 22mm Mid-position Pack Product Page TP2MPV28 22mm Mid-position Pack TMPV Mid-position Valve 12 & 13 TW1 Wiring entre 11 TP2 Programmer 4 & 5 TT1 ylinder Thermostat 10 TRT1 Room Thermostat 8 See page 18/19 for wiring diagrams PROGRMMER WIRING ENTRE TYPIL ZONE VLVE SYSTEM MID POSITION VLVE THERMOSTTI RDITOR VLVE MNUL LOKSHIELD RDITOR VLVE YLINDER THERMOSTT ROOM THERMOSTT IRULTING PUMP DIFFERENTIL PRESSURE VLVE OILER HETING QULITY YOU N TRUST 15

17 Mid-position ontrol Pack including Electro-mechanical Programmer The TMP2TPMV22 pack incorporates the elements required for central heating and hot water control. The pack includes a 22mm mid-position motorised valve and a two channel electro-mechanical programmer. Packs come with complete installation instructions for installing individual items. For further advice on Terrier heating control packs or for their application, please contact our Technical Service Team on For product specification please refer to relevant page. TMPV22 Mid-position Valve TW1 Wiring entre TMP2 Programmer TT1 ylinder Thermostat TRT1 Room Thermostat Model Description Order ode TMP2MPV22 22mm Mid-position ontrol Pack Product Page TMPV22 Mid-position Valve 12 & 13 TW1 Wiring entre 11 TMP2 Programmer 7 TT1 ylinder Thermostat 10 TRT1 Room Thermostat 8 See page 18/19 for wiring diagrams PROGRMMER WIRING ENTRE TYPIL ZONE VLVE SYSTEM MID POSITION VLVE THERMOSTTI RDITOR VLVE MNUL LOKSHIELD RDITOR VLVE YLINDER THERMOSTT IRULTING PUMP ROOM THERMOSTT UTOMTI Y-PSS VLVE OILER 16 HETING QULITY YOU N TRUST

18 ombi ontrol Pack including Electro-mechanical Programmer The TMP1TRT1 pack incorporates the elements required for central heating control. The pack includes a TMP1 single channel electro-mechanical programmer and TRT1 room thermostat. Packs come with complete installation instructions for installing individual items. For further advice on Terrier heating control packs or for their application, please contact our Technical Service Team on For product specification please refer to relevant page. TMP1 Programmer TRT1 Room Thermostat Model Description Order ode TMP1TRT1 ombi ontrol Pack See page 18/19 for wiring diagram Product Page TMP1 Programmer 7 TRT1 Room Thermostat 8 TYPIL ZONE VLVE SYSTEM OMINTION OILER THERMOSTTI RDITOR VLVE MNUL LOKSHIELD RDITOR VLVE UTOMTI Y-PSS VLVE ROOM THERMOSTT PROGRMMER HETING QULITY YOU N TRUST 17

19 Wiring Diagrams Terrier entral Heating and Hot Water Zone ontrol System Schematic Wiring Terrier Mid-position entral Heating and Hot Water ontrol System Schematic Wiring L 230v ac 50Hz Double Pole Isolator N L 230v ac 50Hz Double Pole Isolator N Fuse Fuse TP2 Programmer L N TRT1 Room Thermostat TT 1 ylinder Thermostat TZV Zone Valve rown M lue Grey Orange TZV Zone Valve rown Grey Orange M lue TP2 Programmer L N TT 1 ylinder Thermostat TRT1 Room Thermostat TMPV Mid Position Valve White Grey lue Orange SWL N PL Pump L Pump onnection If not required to be made from oiler Key SWL N PL Pump L L N Pump SWL oiler Switched Live Terminal PL oiler Permanent Live Terminal Pump L Pump Live onnection Terminal (If required by oiler Manufacturer) oiler Pump onnection If not required to be Made from oiler Key SWL PL Pump L oiler Switched Live Terminal oiler Permanent Live Terminal Pump Live onnection Terminal (If required by oiler Manufacturer) L N Pump Terrier entral Heating and Hot Water Zone ontrol System Terminal Wiring Terrier Mid-position entral Heating and Hot Water ontrol System Terminal Wiring 18 HETING QULITY YOU N TRUST

20 Terrier Mid-position entral Heating and Hot Water ontrol System with TMP2 Programmer Schematic Wiring Terrier ombi oiler ontrol Pack with TMP1 Programmer Schematic Wiring L 230v ac 50Hz N Double Pole Isolator Fuse TMP1 Programmer L N TRT1 Room Thermostat ombi oiler SWL N PL Key SWL PL N oiler Switched Live Terminal oiler Permanent Live Terminal Neutral Terminal Note: The wiring shown above is a schematic for combi s with mains voltage control connections only. The ombi ontrol Pack is also suitable for low voltage applications. lways consult boiler instructions for wiring details. Terrier Mid-position entral Heating and Hot Water ontrol System with TMP2 Programmer Terminal Wiring PROGRMMER HW HW H OFF ON ON N L 2 5 Terrier TMP2 PUMP L E N OILER MINS ISOLTOR N E E 240V 50HZ SUPPLY N L (ON) L P/L 10 WY JUNTION OX GREY ORNGE TRT 1 TT 1 WHITE LUE PERMNENT LIVE SUPPLY TO OILER IF REQUIRED TMPV HETING QULITY YOU N TRUST 19

21 Manual Radiator Valves 367 PWH Push Fit 367 LS 368T 367 PDLS* 369 PLS 368TPDLS For small bore and microbore heating systems including ombis. vailable in wheel handle, lockshield and drain off lockshield, there are now millions of Terrier valves in service. To have Pegler quality and reliability at the most vulnerable points of the system makes sound economic sense. ompact design Suitable for sealed systems vailable in matt brass or polished chrome plate Water working pressure up to 10 bar (non-shock) pproved to S Maximum water temperature 120 White handles as standard Screw down lockshield Superior grip characteristics on wheel handle Suitable for use with S2871 Part 1 Table X copper tube and approved alternatives or with screwed iron tube (369 only) omprehensive range of WH, LS and DLS Long life gland packing with rising spindle Gland removal without draining down Matching Thermostatic Radiator Valve (TRV) range available Extension tail piece available 367/368 versions only 368 PWH ngle Pattern No. Size Type Finish Order ode 8mm x mm x 1 2 WH rass mm x mm x mm x 1 2 LS rass mm x mm x mm x 1 2 PWH hromium Plated mm x mm x mm x 1 2 PLS hromium Plated mm x mm x mm x 1 2 DLS rass mm x mm x mm x 1 2 PDLS hromium Plated mm x x 1 2 PWH hromium Plated x 1 2 PLS hromium Plated Straight *Patented Pattern No. Size Type Finish Order ode mm x 1 2 PWH hromium Plated mm x 1 2 PLS hromium Plated mm x 1 2 PDLS hromium Plated T 8/10mm x 1 2 PWH hromium Plated T 15mm x 1 2 PWH hromium Plated T 8/10mm x 1 2 PLS hromium Plated T 15mm x 1 2 PLS hromium Plated T 8/10mm x 1 2 PDLS hromium Plated T 15mm x 1 2 PDLS hromium Plated HETING QULITY YOU N TRUST

22 ngle Push Fit Pattern No. Size Type Finish Order ode mm x PWH hromium Plated with elbow connector 15mm x mm x PLS hromium Plated with elbow connector 15mm x mm x PDLS hromium Plated with elbow connector 15mm x mm x PWH hromium Plated with straight connector 15mm x mm x PLS hromium Plated with straight connector 15mm x mm x PDLS hromium Plated with straight connector 15mm x Straight Push Fit Pattern No. Size Type Finish Order ode mm x PWH hromium Plated with elbow connector 15mm x mm x PLS hromium Plated with elbow connector 15mm x mm x PWH hromium Plated with straight connector 15mm x mm x PLS hromium Plated with straight connector 15mm x WH/LS Size D 15mm DLS Size D 15mm T Dimensions (mm) 367 WH/LS Size D 8/10mm mm WH/LS Size D 8mm mm mm DLS Size D Extension Tail Piece (supplied with nut and olive) Size D 8mm mm mm Size 1 2 x 15mm 40 HETING QULITY YOU N TRUST 21

23 Two way Thermostatic Radiator valves Terrier TRV *Patented OMMENDTION ONSUMER PRODUT DESIGN TEGORY, DESIGN USINESS SSOITION WRDS The Terrier thermostatic radiator valve, manufactured to exacting standards by Pegler to ensure reliability, was awarded the Millennium Product status, but time stops for no one, and the best has been improved. To suit different requirements and applications Terrier is offered in the choice of three packs. Single TRV pack containing one Terrier TRV Terrier TRV with a conventional lockshield Terrier TRV with a drain off lockshield i-directional flow capability ompact design Frost protection 7 Setting range 7-28 pproved to EN215 Suitable for 2 pipe systems Polished chrome plate finish vailable with matching lockshield (see pages 16/17) Double O ring seal Low hysteresis wax sensor 0 setting for positive shut off Improved nominal flow rate for both forward and reverse applications ngle Model Size Description Finish Order ode Terrier 8mm x 1 2 Vertical mounting hromium Plated Two Way 10mm x 1 2 Vertical mounting hromium Plated TRV 15mm x 1 2 Vertical or horizontal mounting hromium Plated mm x with (367 PLS) 10mm x 1 2 matching lockshield hromium Plated mm x mm x 1 2 with (367 PDLS) mm x 1 2 matching drain off hromium Plated mm x 1 2 lockshield Extension for all sizes ETP 21mm rass Tail Piece for all sizes ETPP 21mm hromium Plated (both Extension Tail Pieces supplied with nut and olive) Dimensions (mm) ngle 3 Size 8mm mm mm HETING QULITY YOU N TRUST

24 367 PDLS* 367 PLS Straight Model Size Description Finish Order ode Terrier Two 8/10mm x 1 2 Straight body, hromium Plated Way TRV 15mm x 1 2 vertical head /10mm x 1 2 Straight body, vertical head with mm x 1 hromium Plated 2 368T PLS matching lockshield /10mm x 1 2 Straight body, vertical head with mm x T PDLS matching lockshield hromium Plated Dimensions (mm) Straight Size 8/10mm mm Push Fit Model Size Description Finish Order ode Terrier 10mm x 1 2 Vertical or horizontal Two Way 15mm x 1 2 mounting with Push Fit hromium Plated TRV elbow connector Push Fit Dimensions (mm) Elbow 10mm x 1 2 Vertical or horizontal mm x 1 2 mounting with Push Fit hromium Plated straight connector 10mm x 1 2 with (367 PLS) mm x 1 2 matching lockshield & hromium Plated Push Fit elbow connector 10mm x 1 2 with (367 PLS) mm x 1 2 matching lockshield & hromium Plated Push Fit straight connector 10mm x 1 2 with (367 PDLS) mm x 1 2 matching drain off hromium Plated lockshield & Push Fit elbow connector 10mm x 1 2 with (367 PDLS) mm x 1 2 matching drain off hromium Plated lockshield & Push Fit straight connector Straight Fitting Size 15 x x Terrier TRV fitted horizontally at bottom of radiator HETING QULITY YOU N TRUST 23

25 Decorative Thermostatic and Manual Radiator valves The all chrome TRV and Manual Radiator Valves provide a reliable and aesthetic solution to complement all types of standard or decorative radiators. i-directional flow ompact design Straight & angled options Provides frost protection below 7º vailable in 15mm and 10mm Range from 7º to 28º pproved to EN215 15mm straight and TRV available with push fit Suitable for 2 pipe systems hrome body & matching control vailable with matching lockshield Double O ring seal Low hysteresis wax sensor O setting for positive shut off Improves nominal flow rate for both forward and reverse applications 5 Year functional guarantee TRV ngle Pattern No. Size Description Finish Order ode NGLE 10mm x 1 2 Vertical mounting hromium Plated NGLE 15mm x 1 2 Vertical or hromium Plated horizontal mounting TRV Straight Pattern No. Size Description Finish Order ode STRIGHT 10mm x 1 2 Straight body hromium plated STRIGHT 15mm x 1 2 Vertical head Wheelhead & Lockshield Pattern No. Size Type Finish Order ode NGLE 10mm x 1 2 * WH hromium Plated NGLE 15mm x 1 2 WH hromium Plated NGLE 10mm x 1 2 * LS hromium Plated NGLE 15mm x 1 2 LS hromium Plated Wheelhead & Lockshield Pattern No. Size Type Finish Order ode STRIGHT 10mm x 1 2 * WH hromium Plated STRIGHT 15mm x 1 2 WH hromium Plated STRIGHT 10mm x 1 2 * LS hromium Plated STRIGHT 15mm x 1 2 LS hromium Plated HETING QULITY YOU N TRUST

26 Pack Options Pattern No. Description Finish Order ode 15mm x 1 2 ngle wheelhead & lockshield pack hromium Plated mm x 1 2 ngle wheelhead & lockshield pack hromium Plated mm x 1 2 Straight wheelhead & lockshield pack hromium Plated mm x 1 2 Straight wheelhead & lockshield pack hromium Plated mm x 1 2 ngled TRV & lockshield pack hromium Plated mm x 1 2 ngled TRV & lockshield pack hromium Plated mm x 1 2 Straight TRV & lockshield pack hromium Plated mm x 1 2 Straight TRV & lockshield pack hromium Plated mm x 1 2 Straight TRV & lockshield Pushfit pack hromium Plated mm x 1 2 Straight TRV & lockshield Pushfit elbow pack hromium Plated Dimensions (mm) Wheelhead & Lockshield Straight ngle D Size D *29/30 54 open Dimensions (mm) TRV ngle Dimensions (mm) Wheelhead & Lockshield Straight Straight D Size Size D *33.5/ open Dimensions (mm) TRV Straight Dimensions (mm) TRV Straight Push Fit Size *33.5/ 36 Size HETING QULITY YOU N TRUST 25

27 Decorative Manual Radiator Valves ULTR MODERN Straight ngled The latest offering from Terrier combines quality and the choice of style, which includes; ultra modern, minimalist, modern and traditional cross top. This spectrum of style ensures the perfect match to all designer and contemporary radiators. ll valves are tested in accordance with S , have a working pressure of 4 bar at 95 º and carry a 5 year functional guarantee. Ultra Modern Modern sculptured wheel handle Unique balanced lock shield Polished chrome plated finish Perfect complement to designer radiators Straight & angle pattern options 1/2 x 15mm connections Minimalist/Modern Effortless minimalist styling Matching lockshield & wheel head Simple lockshield mechanism hrome & Satin hrome plated finish options Perfect complement to designer radiators Straight & angle pattern variations 1/2 x 15mm connections rosstop Traditional Timeless traditional design Matches traditional style radiators Polished chrome plated finish Matching wheel head & lockshield valve Ideal for traditional interiors 1/2 x 15mm connections Straight & angle pattern options rosstop Modern Striking rosstop handle design Polished chrome plated finish omplements modern radiator designs Matching wheel head & lockshield valve Straight & angle pattern options 1/2 x 15mm connections Ultra Modern Pattern No. Size Type Finish Order ode NGLE 15mm x 1/2 WH & LS hromium Plated STRIGHT 15mm x 1/2 WH & LS hromium Plated Minimalist/Modern Pattern No. Size Type Finish Order ode NGLE 15mm x 1/2 WH & LS hromium Plated NGLE 15mm x 1/2 WH & LS Satin hrome STRIGHT 15mm x 1/2 WH & LS hromium Plated STRIGHT 15mm x 1/2" WH & LS Satin hrome HETING QULITY YOU N TRUST

28 MINIMLIST/MODERN vailable in hrome/satin hrome ROSSTOP Modern ngled ROSSTOP Traditional Straight ngled Straight ngled Straight rosstop Traditional Pattern No. Size Type Finish Order ode NGLE 15mm x 1 2 WH & LS hromium Plated STRIGHT 15mm x 1 2 WH & LS hromium Plated rosstop Modern Pattern No. Size Type Finish Order ode NGLE 15mm x 1 2 WH & LS hromium Plated STRIGHT 15mm x 1 2 WH & LS hromium Plated Dimensions (mm) Ultra Modern D Size D E F Dimensions (mm) Ultra Modern E F Dimensions (mm) Minialist/Modern D Dimensions (mm) rosstop Traditional D Size D E F G H Size D E F G H Dimensions (mm) rosstop Modern G F E G E H H F D E D E F F Size D E F Size D E F G H G H HETING QULITY YOU N TRUST 27

29 Differential Pressure ypass Valves Prevents unnecessary increases in circulating pressure when thermostatic or motorised valves close, leading to system or valve noise. lso allows water flow for pump overrun in place of a fixed bypass only when required. s recommended for compliance with uilding Regulations Part L1 and L2. vailable in 4 sizes from 22mm up to the Terrier DPV is intended for domestic to light commercial applications. Dimensions (mm) h D H Small proportional deviation Maximum response accuracy due to calibrated high tensile spring Low friction Directly readable adjustment Excellent flow characteristics Gunmetal Setting range mbar Max operating temperature 100º Min operating temperature 1º Max operating pressure 6 bar Description Size Order ode Terrier Differential Pressure Valve 22mm Terrier Differential Pressure Valve Terrier Differential Pressure Valve Terrier Differential Pressure Valve D1 L Size D1( F) D( M) L H h Dimensions (mm) Size D1( F) D( M) L H 22mm 22mm 22mm HETING QULITY YOU N TRUST

30 pplications Flow harts ) System without mixing valves. Installation between discharge and inlet connections of the circulation pump ) System with 3 Way Mixing Valve. Installed between flow and return. E) ombination boiler heating system. Installed between flow and return to maintain minimum volume of water circulating. Key 1 Oil/Gas oiler 2 Water Heater 3 Heating ircuit 4 Radiator ) Heating System with 4 Way Mixer Valve installed between flow and return. D) Typical domestic installation with TRV and Terrier DPV F) System with several heating circuits from central manifold. Installed between flow and return. 5 2, 3 or 4 Way Valves 6 Manifold Distributor Δp(bar) Δp(bar) Δp(bar) Δp(bar) /4" mm Flow-rate Differential pressure " /4" Q(m 3 /h) Q(m 3 /h) Q(m 3 /h) Q(m 3 /h) HETING QULITY YOU N TRUST 29

31 T5 & T6 Domestic irculating Pumps Performance Suitable for indirect open-vented or sealed domestic heating and hot water systems. Designed for quiet operation with three speed settings for maximum flexibility when commissioning. Low power consumption. pproved to S EN & S EN 1151and Kitemarked Licence No. KM Mains Supply - Maximum Head - Maximum Pressure - Minimum Pressure - Pipe onnections v 50Hz T5-5M T6-6M 10.0 bar 0.15 bar System Water Temperature - Minimum 5 Maximum 110 Maximum mbient Temperature - 35 Weight - Description /2 SPM 2.6 Kg Order ode T5 Terrier irculating Pump 5 metre head T6 Terrier irculating Pump 6 metre head Dimensions (mm) Electrical Data 1 1 /2 SPM Speed T5 T6 Setting urrent () Input (W) urrent () Input (W) HETING QULITY YOU N TRUST

32 Installation Preparation 1) efore installation, the system should be thoroughly flushed to remove all sediment and other solids in accordance with S5449: ) It is recommended that the pump is fitted so that it can be isolated from the system water by the use of an isolating valve fitted to each end of the pump e.g. Pegler ulldog P300P pump isolating valves or similar. 3) Ensure that the pump is fitted so that the drive shaft of the pump is either horizontal or slightly above the horizontal position at the vent screw end. Under no circumstances must the shaft be below horizontal, vertical or near vertical, as this will damage the pump bearings and cause premature failure. 4) Ensure that the position selected for the pump gives access to the speed selector switch and to the terminal box/electrical connections. 5) No part of the pump must be fitted closer than 25mm from any combustible surface. Electrical Wiring 1) The electrical installation of the pump must comply with S7671: 2001 and be carried out by a suitably qualified electrician. 2) The electricity supply connected to the pump must be fused at 3 and be connected using a three-core heat resisting flex with a minimum cross-sectional area of 0.75mm 2 in each core. 3) Ensure that the electrical supply to the pump can be isolated fully either by means of a two-pole isolator with a minimum of 3mm contact separation in both poles or by means of a plug and socket. 4) Terrier T5 and T6 circulating pumps must be earthed. Typical pplications for Terrier Pumps Test Pressure: 24bar/30 Maximum Working Pressure: PN16 (16bar) Maximum Operating Temperature: 120 Description irculating Pump Isolating Valves NOTE: The maximum pressure and temperature conditions are limited by the inlet compression connections manufactured to EN Order ode 22mm 1 off mm 1 off mm 2 off mm 2 off Open Vent old Feed Isolating Valve Dimensions (mm) oiler Terrier irculating Pump Isolating Valve Model oiler Terrier irculating Pump HETING QULITY YOU N TRUST 31

33 VENTIR ir Separators Dimensions (mm) Material: S2871 Table X opper tubing. Finish: Sprayed opper Pigment. Max ir Pressure 70lbs PSI Patt. No Description SIZES 22mm 28mm VEN 1201 Order ode VEN 1201 ir Separator VEN 1401 ir Separator Method of Operation The design of Ventair is both simple and effective. Unlike other devices air bubbles are not 'forced out' but simply diverted to an open vent. It relies on the natural buoyancy of the air (or gas) bubbles. Sludge or particles present in any system remain undisturbed. Valves and pump chambers are therefore protected ensuring a longer working life. If over heated water or steam is expelled via Ventair the water lost will be replaced automatically via the cold feed. This ensures the safe and constant running of the system. E D Recommended Installation Ventair can be installed simply. 1. Pipework to the Ventair should rise continuously from the boiler in accordance with standard practice. 2. Position the Ventair with the vent outlet pointing upwards. 3. It is important that the open vent pipe is fitted correctly. It should never dip below the horizontal level at any time, always rising in the horizontal plane to its discharge point above the water level in the cistern. Installation instructions and suggested schemes are packed with each unit. pplications GRVITY HOT WTER PUMPED HETING Sizes D E 22mm mm TWO PORT VLVES SYSTEM OPEN VENT THREE PORT VLVE SYSTEM Where boiler manufacturer recommends that the cold feed is taken direct to the boiler, the cold feed connection to the VENTIR must be blocked off. OLD FEED FEED TO PUMPED IRUIT Key Ventair 3 Port Zone Valve 2 Port Zone Valve istern alancing Valve Pump Flow to Radiator Return to oiler Feed and Expansion istern oiler Indirect ylinder FLOW FROM OILER NOTE: The diagrams above indicate typical applications. In all cases reference must be made to boiler installation requirements. 32 VENTIR HETING HETING QULITY QULITY YOU N YOUTRUST N TRUST

34 Everything you need to know - online The Pegler website home page the Pegler website is easy to navigate and has been designed to provide all the information you might need. orporate information rochure downloads News Product range Training Price lists ontact details HETING QULITY INFORMTION YOU N YOU TRUST N TRUST 33

35 Terrier product range pages Product information - online Terrier TRV care and maintenance Terrier Radiator Valves Terrier TRV pressure and temperature Terrier TRV general information Terrier TRV materials specification Terrier TRV guarantee/warranty Terrier TRV dimensions Terrier TRV spares 34 INFORMTION YOU N TRUST

36 You don t have to travel to benefit from Pegler training The training section of the website features two interactive training modules which have been developed to provide a guide to the latest in plumbing and central heating systems, controls and legislation and can be used to gain onstruction PD ertification. Pegler e-learning Heating system components e-learning heating module contents Schematic wiring PD ertification Self testing INFORMTION YOU N TRUST 35

The new Terrier Belmont Thermostatic Radiator Valve range

The new Terrier Belmont Thermostatic Radiator Valve range The new Terrier elmont Thermostatic Radiator Valve range Manual Radiator Valves The new manual radiator valve range offering both traditional handwheel and lockshield styles, along with a new concealed

More information

Heating Controls Thermostatic and Manual Radiator Valve range

Heating Controls Thermostatic and Manual Radiator Valve range Heating ontrols Thermostatic and Manual Radiator Valve range Heating ontrols New thermostatic and manual radiator valves with built-in energy saving solutions With increasing demands on specifiers and

More information

For more information on Pegler Yorkshire visit Heating Controls. Radiator valves with new integral push-fit inlet

For more information on Pegler Yorkshire visit  Heating Controls. Radiator valves with new integral push-fit inlet Heating Controls Radiator valves with new integral push-fit inlet Heating Controls Radiator valves with new integral push-fit inlet Terrier is a name which should need no introduction to the professional

More information

Price list 1st March 2011

Price list 1st March 2011 Price list st March 20 Contents Heating solutions Terrier Heating Controls -4 Terrier ll Chrome Decorative Manual Radiator Valves 4 Terrier ll Chrome Decorative Thermostatic Radiator Valves Terrier Manual

More information

LOCKSHieLD. ReMOTe ADJUSTeR. MANUAL VALVeS. Belmont commercial radiator valves. Pegler Yorkshire

LOCKSHieLD. ReMOTe ADJUSTeR. MANUAL VALVeS. Belmont commercial radiator valves. Pegler Yorkshire TRV LOKSHieLD ReMOTe DJUSTeR TRV MNUL VLVeS elmont commercial radiator valves Pegler Yorkshire Pegler Yorkshire Unrivalled quality, innovation, customer service and long-term value for money s part of

More information

TRV & Lockshield Pack Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting with (367 CPLS) matching lockshield

TRV & Lockshield Pack Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting with (367 CPLS) matching lockshield TRV & Lockshield Pack Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting with (367 CPLS) matching lockshield GENERAL INFORMATION Size Pattern No. Pack 1 Qty Code Barcode Angle Pattern

More information

Straight pattern thermostatic radiator valve vertical or horizontal mounting with (368T CPDLS) matching drain off lockshield

Straight pattern thermostatic radiator valve vertical or horizontal mounting with (368T CPDLS) matching drain off lockshield Straight pattern thermostatic radiator valve vertical or horizontal mounting with (368T CPDLS) matching drain off lockshield Straight pattern TRV & drain off lockshield pack Size Pattern No. Pack 1 Qty

More information

PRECISION CONTROL FROM MYSON PLUS

PRECISION CONTROL FROM MYSON PLUS THERMOSTATS PROGRAMMABLE ROOM THERMOSTATS PROGRAMMERS MOTORISED VALVES MYSON PLUS Eastern Avenue, Team Valley, Gateshead, Tyne & Wear NE11 0PG, UK T: 0845 402 3434, F: 0191 491 7568 TRVS PRECISION CONTROL

More information

CONTROL UNIT FOR UNDERFLOOR HEATING SYSTEMS

CONTROL UNIT FOR UNDERFLOOR HEATING SYSTEMS ST.04.04.00 ONTROL UNIT FOR UNERFLOOR HETING SYSTEMS Low temperature control unit Low+high temperature control unit 1. ONTROL UNIT PPLITION The FR control unit is suitable for systems combining both high

More information

Francis Pegler Memento Single Sequential Exposed Thermostatic Shower

Francis Pegler Memento Single Sequential Exposed Thermostatic Shower e x p e r i e n c e d e s I g n i n n o v a t i o n You re Guide to the Installation, Care and maintenance of Francis Pegler Memento Single Sequential Exposed Thermostatic Shower For further information,

More information

ESi CONTROLS BROCHURE LANDSCAPE V5.indd 1 14/08/ :31

ESi CONTROLS BROCHURE LANDSCAPE V5.indd 1 14/08/ :31 ESi CONTROLS BROCHURE LANDSCAPE V5.indd 1 14/08/2014 18:31 The ESi family of programmers are a feature packed range, offering flexibility and reliability for use in any domestic heating and hot water installations.

More information

FLEXIBLE METAL - BENDING THE RULES OF PLUMBING CONNECT WITH CONFIDENCE SEE OUR NEW EXTENDED RANGE OF VALVES -

FLEXIBLE METAL - BENDING THE RULES OF PLUMBING CONNECT WITH CONFIDENCE SEE OUR NEW EXTENDED RANGE OF VALVES - FLEXIBLE METAL - BENDING THE RULES OF PLUMBING CONNECT WITH CONFIDENCE SEE OUR NEW EXTENDED RANGE OF VALVES - AVAILABLE FROM JULY 2014 THE TECTITE FLEXIBLE METAL SYSTEM Every customer relies on you to

More information

Flow Solutions Valves for Heating System Control

Flow Solutions Valves for Heating System Control Flow Solutions Valves for Heating System Control Thermostatic Radiator Valves Manual Radiator Valves Motorised Zone Valves Domestic Heating System Valves Valves for Heating System Control Controlling domestic

More information

IMAGINATION SOLAR LTD. Installation Guide B1. Planning the Plumbing and Wiring

IMAGINATION SOLAR LTD. Installation Guide B1. Planning the Plumbing and Wiring Page 1 of 8 IMAGINATION SOLAR LTD Installation Guide B1 Planning the Plumbing and Wiring Unit 4 Montpelier Central, Station Road Bristol BS6 5EE t: 0117 942 6668 f: 0117 942 8998 e: enquiries@imaginationsolar.com

More information

Heating Controls Technical

Heating Controls Technical 472 Room Thermostat Voltage Rating: 230V AC 50Hz Switch Rating: Terminal 3 10A resistive, 3A inductive Terminal 4 6A resistive, 2A inductive Single pole, double throw (SPDT) Temperature Setting Range:

More information

RA2000 Commercial TRVs

RA2000 Commercial TRVs RA2000 Commercial TRVs www.heating.danfoss.co.uk Danfoss Limited Ampthill Road Bedford MK42 9ER E: ukheating@danfoss.com W: www.heating.danfoss.co.uk Reception Tel: 01234 364621 Fax: 01234 219705 UK Sales

More information

STRAIGHT AND ANGLED THERMOSTATIC VALVES

STRAIGHT AND ANGLED THERMOSTATIC VALVES ST.07.01.00 STRIGHT ND NGLED THERMOSTTIC VLVES 1. DESCRIPTION FR thermostatic valves are preset for assembly of thermostatic and thermo-electric actuators, which control opening and closure. rt. 16 Chrome-plated

More information

QUALITY DESIGN. BUILT-IN RELIABILITY. CYLINDERS. The complete range of Warmflow Cylinders.

QUALITY DESIGN. BUILT-IN RELIABILITY. CYLINDERS. The complete range of Warmflow Cylinders. QULITY DESIGN. UILT-IN RELIILITY. YLINDERS The complete range of Warmflow ylinders QULITY DESIGN. UILT-IN RELIILITY. YLINDERS Warmflow - the perfect choice Warmflow has been established as a privately

More information

Sirius FS. Working towards a cleaner future

Sirius FS. Working towards a cleaner future Sirius FS Floor Standing Stainless Steel Condensing Boilers Single Boiler Applications: 50 to 160kW Modular Boiler Applications: up to 640kW Working towards a cleaner future heating specialists 1. Product

More information

Cylinder/Pipe Thermostat Cat. No. TRT044. Operating & Installation Instructions

Cylinder/Pipe Thermostat Cat. No. TRT044. Operating & Installation Instructions Cylinder/Pipe Thermostat Cat. No. TRT044 Operating & Installation Instructions What is a cylinder thermostat?... an explanation for householders A cylinder thermostat switches on and off the heat supply

More information

Installation & User Instructions

Installation & User Instructions 3060 electro-mechanical programmer for controlling heating & hot water Installation & User Instructions This product complies with the following EC Directives: Electro-Magnetic Compatibility Directive.

More information

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW Stainless steel range of condensing boilers Outputs from 50kW to 660kW Designed to meet carbon reduction targets Lifetime service and support Totally dependable. page 1 www.pottertoncommercial.co.uk Contents

More information

Installation, operating and servicing instructions

Installation, operating and servicing instructions English 57-115 - 144-1 - 259 Installation, operating and servicing instructions ITALIA EN 1 ITALIA English INDEX WARnINGS 3 Who should read these instructions 3 Symbols 3 Recommendations 3 Importants notes

More information

Vented systems explained Performance without compromise Vented System (Gravity Fed) Positive Head Systems

Vented systems explained Performance without compromise Vented System (Gravity Fed) Positive Head Systems Vented systems explained Vented System (Gravity Fed) Typically used in older properties, this indirect system uses the mains water supply to feed a cold water storage tank, usually located in the roof

More information

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Reduced Installation time Precision regulation Minimal tooling required 100% tested prior to packaging High quality

More information

Komo Thermostatic Bar Shower. Excluding Shower Kit

Komo Thermostatic Bar Shower. Excluding Shower Kit Komo Thermostatic Bar Shower. Excluding Shower Kit Bar Shower Size Pattern No. Pack 1 Qty Pack 2 Qty Code Barcode Price ( ) ex VAT NA Bar Shower CP 1 0 4S4001 5013866052750 180.25 Bar Shower Code 4S4001

More information

DOMESTIC HEATING CONTROLS ARE EASY PART 1 - THE BASICS

DOMESTIC HEATING CONTROLS ARE EASY PART 1 - THE BASICS DOMESTIC HEATING CONTROLS ARE EASY PART 1 - THE BASICS Today s inescapable need to improve energy efficiency in UK homes has brought installers many opportunities to make extra earnings through the upgrading

More information

Thermostatic Bath Shower Mixer. Without shower kit.

Thermostatic Bath Shower Mixer. Without shower kit. Thermostatic Bath Shower Mixer. Without shower kit. 555QT Size Pattern No. Pack 1 Qty Pack 2 Qty Code Barcode Price ( ) ex 555QT Code A B C D E F Pegler Yorkshire reserve the right to change specifications

More information

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support Aluminium range of condensing boilers Outputs from 30kW to 600kW Designed to meet carbon reduction targets Lifetime service and support Works every time. www.pottertoncommercial.co.uk Aluminium range of

More information

thermocompact High performance system boiler range

thermocompact High performance system boiler range thermocompact High performance system boiler range Built-in performance The expectations of today s system boiler have never been more demanding, which is why Vaillant s thermocompact range comes with

More information

Quartz. Digital. Bath with bath waste filler. Quartz Digital Bath with bath waste filler installation instuctions page 1

Quartz. Digital. Bath with bath waste filler. Quartz Digital Bath with bath waste filler installation instuctions page 1 Quartz Digital Bath with bath waste filler The Waste Electrical and Electronic Equipment (Producer Responsibility) Regulation 2004 This product is outside the scope of the European Waste Electrical and

More information

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support Aluminium range of condensing boilers Outputs from 30kW to 600kW Designed to meet carbon reduction targets Lifetime service and support Works every time. www.pottertoncommercial.co.uk Aluminium range of

More information

In-line thermostatic mixing valves

In-line thermostatic mixing valves In-line thermostatic Pegler Yorkshire Unrivalled quality, innovation, customer service and long-term value for money As part of the global Aalberts Industries NV Group, Pegler Yorkshire is one of Britain

More information

CPC-180-ABNAB. 180 litres, 535mm x 1550mm high

CPC-180-ABNAB. 180 litres, 535mm x 1550mm high 6 8 9 10 1 3 7 2 4 11 13 17 5 28 21 20 19 18 30 Wiring Pandora Heat Bank. 100kW Plate Heat Exchanger with 22mm Thermostatic Mixing Valve. Indirectly Heated. Cylinder Thermostat. Manually Filled store -

More information

RA15/6T & TB Conversion Valve

RA15/6T & TB Conversion Valve Applications: continue on. This provides continuous flow, but inherent to series piping the supply water temperature will decrease as it flows through the system and when it mixes with return water from

More information

Section - A. Radiator Valves

Section - A. Radiator Valves Section - Radiator Valves RDITOR VLVES EXMPLE OF PPLICTION 2 6 9 3 5 7 1 4 8 2 1 Thermostat adaptable valves. 2 Lockshield valves. 3 4-way thermostat adaptable valves for one-pipe and two-pipe systems.

More information

Underfloor Catalogue Heating products that define the market

Underfloor Catalogue Heating products that define the market YEAR 5 WARRANTY Underfloor Catalogue Heating products that define the market By Underfloor Heating Control We provide a range of room temperature controls (thermostats) to optimize the operating efficiency

More information

Electronic Dual Cylinder Thermostat Installation Instructions

Electronic Dual Cylinder Thermostat Installation Instructions ESCTDEB Electronic Dual Cylinder Thermostat Installation Instructions Thank you for choosing ESi Controls. All our products are tested in the UK so we are confident this product will reach you in perfect

More information

Rise. Digital. Bath with overflow filler. Rise Digital Bath installation instuctions page 1

Rise. Digital. Bath with overflow filler. Rise Digital Bath installation instuctions page 1 Rise Digital Bath with overflow filler The Waste Electrical and Electronic Equipment (Producer Responsibility) Regulation 2004 This product is outside the scope of the European Waste Electrical and Electronic

More information

INSTALLATION & TECHNICAL MANUAL

INSTALLATION & TECHNICAL MANUAL The FUSION Range of Boilers INSTALLATION & TECHNICAL MANUAL If you require any further assistance: Telephone: 01698 820533 Fax: 01698 825697 E-mail: info@electric-heatingcompany.co.uk Or visit our website

More information

Radiator Valve Program

Radiator Valve Program Radiator Valve Program Heat seeks cold faster when the temperature difference is greater. Lowering the temperature of a room reduces the amount of heat leaving the room (heat loss). Installing thermostats

More information

Pegler Yorkshire reserve the right to change specifications. 10 Year Guarantee Luxury Taps and Mixers

Pegler Yorkshire reserve the right to change specifications. 10 Year Guarantee Luxury Taps and Mixers Opal Bath Tap Bath Tap Size Pattern No. Pack 1 Qty Pack 2 Qty Code Barcode Price ( ) ex VAT Bath Tap Code A B C D Pegler Yorkshire reserve the right to change specifications 10 Year Guarantee Luxury Taps

More information

POWER SHOWERS Models 4500M 5002M 4500T 5002T

POWER SHOWERS Models 4500M 5002M 4500T 5002T II POWER SHOWERS Models 4500M 5002M 4500T 5002T Performance Shower Products CUSTOMER SERVICE HELPLINE: 01883 730339 CONTENTS PLEASE READ THESE INSTRUCTIONS CAREFULLY: This booklet covers all models in

More information

Handy Dri / Hair Drier

Handy Dri / Hair Drier Handy Dri / Hair Drier Warm air dryers Handy Dri / Hair Drier Warm air dryers are the cleanest, cheapest way of providing hand and hair drying facilities. We ve developed three types: the Handy Dri hand

More information

Aquamixa. Thermo. Thermostatic shower valve with manual bath fill

Aquamixa. Thermo. Thermostatic shower valve with manual bath fill Aquamixa Thermo Thermostatic shower valve with manual bath fill Aquamixa Thermo thermostatic shower valve with manual bath fill installation instuctions page 1 Shower systems Aquamixa Thermo (300.01) with

More information

CI/SfB. (53.3) x. October Unvented Water Heaters. PremierPlus. Unvented Hot Water Cylinders

CI/SfB. (53.3) x. October Unvented Water Heaters. PremierPlus. Unvented Hot Water Cylinders I/SfB (53.3) x October 2013 PremierPlus Unvented Hot Water ylinders Unvented Water Heaters Unvented Water Heaters PremierPlus Mains Pressure Unvented Water Heating Designed and manufactured in the UK the

More information

Manufacturers of Cast Iron Radiators. Beaumont

Manufacturers of Cast Iron Radiators. Beaumont Manufacturers of Cast Iron Radiators Beaumont Radiators Rococo Royale The The stunning Rococo Royale cast iron radiator blends with any period setting and offers a very high heat output. Where a period

More information

CT range. of shower, bathroom and whole house pumps

CT range. of shower, bathroom and whole house pumps CT range of shower, bathroom and whole house pumps 2 Salamander Pumps is one of the UK s leading manufacturers of shower and domestic water pumps. Innovation is used throughout the organisation to create

More information

RA 2000 Series RA 15/6T & TB Conversion Valve

RA 2000 Series RA 15/6T & TB Conversion Valve RA 2000 Series RA 15/6T & TB Conversion Valve Applications: RA15/6T Internal bypass allowing for series piping to the radiators/baseboards. This series piping provides continuous flow but the supply water

More information

DANESMOOR 12-14, 15-19, 20-25, 26-32, 32-50, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

DANESMOOR 12-14, 15-19, 20-25, 26-32, 32-50, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE DANESMOOR 12-14, 15-19, 20-25, 26-32, 32-50, 50-70 FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE EXCELLENCE COMES AS STANDARD Thank you for purchasing a Danesmoor

More information

MEGAFLO HE Iss 1

MEGAFLO HE Iss 1 MEGAFLO HE 1 36 00 5843 Iss 1 Contents Contents SECTION PAGE 1 INTRODUCTION... 3 2 GENERAL REQUIREMENTS... 4 3 INSTALLATION - GENERAL... 5 4 INSTALLATION - DIRECT UNITS... 8 5 INSTALLATION - INDIRECT UNITS...

More information

turbomax plus High performance combination boiler range

turbomax plus High performance combination boiler range turbomax plus High performance combination boiler range The winning combination High performance, simple installation and servicing are combined in the turbomax plus combination boiler range. Vaillant

More information

Multipoint. Unvented point of use hot water

Multipoint. Unvented point of use hot water Unvented point of use hot water Many different types of large commercial and industrial organisations need a reliable supply of hot water for up to 0 basins or sinks and we have developed the Multipoint

More information

HEATRAE SADIA. Installation and User Instructions for the UTC Undersink Vented Water Heater

HEATRAE SADIA. Installation and User Instructions for the UTC Undersink Vented Water Heater HEATRAE SADIA The quality name in water heating Installation and User Instructions for the UTC Undersink Vented Water Heater UTC 15 Please read and understand these instructions before starting work. Please

More information

Grant Energy Management Control Systems. Includes weather compensation, sequence controllers, low loss headers and zone pumps

Grant Energy Management Control Systems. Includes weather compensation, sequence controllers, low loss headers and zone pumps Grant Energy Management Control Systems Includes weather compensation, sequence controllers, low loss headers and zone pumps Reduces heating bills Environmentally friendly Header systems suitable for systems

More information

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A B C D E F G H I J K L M N O P Q R S T U V W X Y Z Ambient temperature This is the air temperature within a 21 ºC room at any given time. It depends

More information

Streamline. Vented point of use hot water

Streamline. Vented point of use hot water Streamline Vented point of use hot water Streamline Quick access to hot water can be a serious health and safety issue or a simple matter of comfort. It all depends on where, or for what, it s needed.

More information

Dynamic thermostatic radiator valves DYNAMICAL

Dynamic thermostatic radiator valves DYNAMICAL ynamic thermostatic radiator valves YNMIL -----7 series RIT ISO 9 M 6 /7 G unction The YNMIL valve allows the automatic dynamic balancing and pressure-independent adjustment of the thermal medium in the

More information

Basin Tap. Time delay maximum 2 seconds

Basin Tap. Time delay maximum 2 seconds Basin Tap. Time delay maximum 2 seconds 876 Size Pattern No. Pack 1 Qty Pack 2 Qty Code Barcode Price ( ) ex 1/2 876 Hot 1 5 314007 5013866005022 142.41 1/2 876 Cold 1 5 314017 5013866005039 142.41 876

More information

Thermostat install guide

Thermostat install guide Thermostat install guide 74_Hive Thermostat Install Guide_97mmx97mm_v3.indd 1 23/11/2015 14:0 Install Guide For Hive Active Heating the thermostat, receiver and hub are installed together so heating and

More information

COMPRESSION PLUMBING SOLUTIONS CONNECT WITH CONFIDENCE

COMPRESSION PLUMBING SOLUTIONS CONNECT WITH CONFIDENCE COMPRESSION PLUMBING SOLUTIONS CONNECT WITH CONFIDENCE CONNECT WITH CONFIDENCE With a wealth of expertise and the broadest range of solutions and systems on the market, Pegler Yorkshire s Connect products

More information

Installation and User Guide. Electro-mechanical 24 hour timeswitch for controlling hot water and heating (Including Factory Replacement Units FRU)

Installation and User Guide. Electro-mechanical 24 hour timeswitch for controlling hot water and heating (Including Factory Replacement Units FRU) 103 Electro-mechanical 24 hour timeswitch for controlling hot water and heating (Including Factory Replacement Units FRU) Danfoss Heating Installation and User Guide Index Installation Product specification

More information

OFC1000, OFC1500, OFC2000, OFC2500 OFC1000TI, OFC1500TI, OFC2000TI & OFC2500TI

OFC1000, OFC1500, OFC2000, OFC2500 OFC1000TI, OFC1500TI, OFC2000TI & OFC2500TI OFC1500TI OFC1000, OFC1500, OFC2000, OFC2500 OFC1000TI, OFC1500TI, OFC2000TI & OFC2500TI 08/35286/5 (UK) Issue 5 Products comply with the European Safety Standard: EN 60335-2-30 and the European Standards

More information

Underfloor Heating and Cooling Controls RELIABLE, ENERGY EFFICIENT CONTROLS FEATURING UNIQUE

Underfloor Heating and Cooling Controls RELIABLE, ENERGY EFFICIENT CONTROLS FEATURING UNIQUE Underfloor Heating and Cooling Controls RELIABLE, ENERGY EFFICIENT CONTROLS FEATURING UNIQUE 110763_UPONOR_CONTROLS_BROCHURE_AW.indd 1 7/8/2013 12:04:56 AM Indoor Climate: Controls Auto Balance Technology

More information

Alpha CombiMax 350 and 600

Alpha CombiMax 350 and 600 Installation and Servicing Instructions Alpha CombiMax 350 and 600 Unvented Hot Water Store for use with the Alpha 240/280 Range of Gas Fired Combination Boilers For Technical help or for Service call...

More information

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500 Unvented Calorifier Range. Operating and Maintenance Manual. For Models 125 300 & 500 Telephone 08456 448802 Fax 08456 448803 Emial info@mhgheating.co.uk Web www.mhgheating.co.uk TABLE OF CONTENTS. Section

More information

ADVANCE ECB ELECTRIC COMBINATION BOILER

ADVANCE ECB ELECTRIC COMBINATION BOILER ISSUE ISSUE 45 0115 0317 INSTALLATION AND USER GUIDE ADVANCE ECB ELECTRIC COMBINATION BOILER ADVANCE APPLIANCES LTD HOUSEHOLDER - PLEASE RETAIN AND ENSURE SERVICE RECORDS ARE KEPT UP TO DATE 1 SCHEMATIC

More information

Installation and User Guide. Electro-mechanical mini programmer for controlling hot water and heating Including Factory Replacement Units (FRU)

Installation and User Guide. Electro-mechanical mini programmer for controlling hot water and heating Including Factory Replacement Units (FRU) 102 Electro-mechanical mini programmer for controlling hot water and heating Including Factory Replacement Units (FRU) Danfoss Heating Installation and User Guide Index Installation Product specification

More information

WATER HEATERS. Simplicity, performance, comfort... Hydraflo. Unvented Cylinders. 125 to 300 litres, directly or indirectly heated.

WATER HEATERS. Simplicity, performance, comfort... Hydraflo. Unvented Cylinders. 125 to 300 litres, directly or indirectly heated. WATER HEATERS Simplicity, performance, comfort... Hydraflo Unvented Cylinders 125 to 300 litres, directly or indirectly heated. Unvented Hot Water Supply Systems Our unvented cylinders make life easier,

More information

INDEPENDENT COMBINATION & SYSTEM BOILERS.

INDEPENDENT COMBINATION & SYSTEM BOILERS. INDEPENDENT COMBINATION & SYSTEM BOILERS. RELIABLE IDEAL BOILERS EXCLUSIVELY AVAILABLE AT YOUR LOCAL INDEPENDENT MERCHANT. *7 YEAR WARRANTY UNTIL 31ST DEC 2016 ON INDEPENDENT+. 1 GREAT BOILERS FROM GREAT

More information

High Efficiency Boilers & Accessories

High Efficiency Boilers & Accessories High Efficiency Boilers & Accessories 2 ontents This brochure has been developed to provide you with all the information you could ever want to know about the Glow-worm range of high efficiency boilers.

More information

Sirius WH. Working towards a cleaner future

Sirius WH. Working towards a cleaner future Sirius WH Wall Hung Stainless Steel Condensing Boilers Single Boiler Applications: 50 to 110kW Modular Boiler Applications: up to 880kW Working towards a cleaner future heating specialists 1. Product Overview

More information

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS G R A N T C Y L I N D E R & S T O R E R A N G E High Efficiency Direct and Indirect Hot Water Storage Solutions FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS GRANT DUOWAVE

More information

Maincor Air Temperature Controls AIR TEMPERATURE CONTROL

Maincor Air Temperature Controls AIR TEMPERATURE CONTROL AIR TEMPERATURE CONTROL Overview In multi-zone systems, a thermostat is positioned in the room which is being heated and is set to the required temperature. Once the room gets up to the pre-set temperature,

More information

Installation & User Instructions

Installation & User Instructions Storage Cylinder Grant DuoWave Plus System Triple Coil Solar Cylinder Range Installation & User Instructions Part. IRL 21. Rev 00. June 2011 Do not fit on a well or borehole supply Contents 1 Introduction

More information

Function series Thermo-electric actuator electric supply 230 V (ac) or 24 V (ac/dc)

Function series Thermo-electric actuator electric supply 230 V (ac) or 24 V (ac/dc) onvertible radiator valve for one-pipe and two-pipe systems series ARIT 0/ G ISO 0 M ISO 0 No. 000 unction The series convertible radiator valve can be used both on one-pipe and two-pipe radiator systems.

More information

TC MODULE (FFD) (with Gas Hob)

TC MODULE (FFD) (with Gas Hob) TC MODULE (FFD) (with Gas Hob) Installation Instructions REMEMBER: when replacing a part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification

More information

Jetflush 4 Instruction Manual

Jetflush 4 Instruction Manual The Sentinel range of water treatment products for domestic central heating systems. GE Water & Process Technologies Jetflush 4 Instruction Manual Foundry Lane, Widnes, Cheshire WA8 8UD. Tel: 0151 420

More information

ecomax pro High efficiency condensing boiler range for traditional systems

ecomax pro High efficiency condensing boiler range for traditional systems ecomax pro High efficiency condensing boiler range for traditional systems High performance for traditional systems A first for Vaillant - the ecomax pro high efficiency condensing boiler range. Delivering

More information

Installation and Operating Instructions. Budget priced instant boiling water heater for beverages.

Installation and Operating Instructions. Budget priced instant boiling water heater for beverages. Installation and Operating Instructions Zip Econoboil Budget priced instant boiling water heater for beverages. Model No. Description Reg.No. Part No. HS503 Zip Econoboil 3.0 litre White EB003 103592 HS505

More information

Thermostatic mixing valves. Pegler Yorkshire

Thermostatic mixing valves. Pegler Yorkshire Thermostatic Pegler Yorkshire Pegler Yorkshire Unrivalled quality, innovation, customer service and long-term value for money As part of the global Aalberts Industries NV Group, Pegler Yorkshire is one

More information

Ultimate 3. Range Brochure

Ultimate 3. Range Brochure Range rochure 2 3 ontents combi boiler 4 Easy does it t Glow-worm we make working with us easy and rewarding with all the support when you need it. We offer outstanding products, practical hands-on training

More information

Technical Checklist - Plumbing and Heating Fittings - UK Sizes

Technical Checklist - Plumbing and Heating Fittings - UK Sizes Technical Checklist - Plumbing and Heating Fittings - UK Sizes July 2008 NOTE: This checklist refers exclusively to fittings and accessories from our range of push-fit products for Plumbing and Heating

More information

1592P01. for liquids in piping DN

1592P01. for liquids in piping DN 1 594 1592P01 Flow switch for liquids in piping DN 20 200. QVE1901 Contact load / switching capacity: max. AC 230 V, 1 A, 26 VA max. DC 48 V, 1 A, 20 W Nominal pressure PN25 Manual setting of contact type

More information

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION SOLARCYL IM/SC INSTALLATION MANUAL This manual gives detailed advice for installation and should be read carefully prior to fitting any unvented

More information

Exhaust Gas Heat Exchangers

Exhaust Gas Heat Exchangers Exhaust Gas eat Exchangers eat Transfer Technology from owman eat Exchanger Technology by World Leader in eat Exchanger Technology Turning waste heat owman Exhaust Gas eat Exchangers Recovering valuable

More information

ZIP Varipoint III. Installation, Maintenance and User Instructions. Models VP303, VP503 VP803, VP953 direct unvented water heaters. Issued August 2008

ZIP Varipoint III. Installation, Maintenance and User Instructions. Models VP303, VP503 VP803, VP953 direct unvented water heaters. Issued August 2008 Varipoint cover qxd:varipoint cover qxd 22/8/08 11:14 Page 1 Installation, Maintenance and User Instructions ZIP Varipoint III Models VP303, VP503 VP803, VP953 direct unvented water heaters Issued August

More information

Understand and apply domestic central heating system installation and maintenance techniques

Understand and apply domestic central heating system installation and maintenance techniques Level: 2 Credit value: 10 URN: Y/602/2888 Unit aim This combination unit provides basic learning in the installation, maintenance, decommissioning and soundness testing of a basic range of wet central

More information

Zip Econoboil. On wall boiling water. Installation instructions & user manual. Model number: ,

Zip Econoboil. On wall boiling water. Installation instructions & user manual. Model number: , Zip Econoboil On wall boiling water. Model number: 305542, 303542 1 Table of contents Intended Use... 2 Warnings and precautions... 3 Before installation... 5 Technical specification... 6 Installation

More information

Easicom 3. Range Brochure

Easicom 3. Range Brochure Range rochure 2 ESIOM 3 ESIOM 3 3 ontents combi boiler 4 Easy does it t Glow-worm we make working with us easy and rewarding with all the support when you need it. We offer outstanding products, practical

More information

opening new doors worldwide...

opening new doors worldwide... opening new doors worldwide... rosslee plc is established as Europe s largest independent tumble dryer manufacturer. s the tumble dryer specialists, the company has the experience and resources to produce

More information

Installation and User Guide Please leave this guide with the end user (for future reference)

Installation and User Guide Please leave this guide with the end user (for future reference) Contact and Commissioning Details Installer Contact Name and Address : Model N : Serial N : Date Installed : Installation and User Guide Please leave this guide with the end user (for future reference)

More information

Assessment Schedule - TS.6

Assessment Schedule - TS.6 The Assessor shall determine the business s commitment and support to good and safe working practices; also that it has a positive culture in all aspects of its work. In particular, the assessor shall

More information

Reliability. Quality. Drayton. Product Catalogue Performance. Efficiency HEATING. Invensys Controls Part of the Invensys Group

Reliability. Quality. Drayton. Product Catalogue Performance. Efficiency HEATING. Invensys Controls Part of the Invensys Group For latest prices and delivery to your door visit MyTub td - www.mytub.co.uk - info@mytub.co.uk 0844 556 1818 Catalogue 2010 HEATIG Efficiency Quality Performance Reliability Invensys Controls Part of

More information

The New Caroma TMV20

The New Caroma TMV20 specify.caroma.com.au The New Caroma TMV The high performance Caroma TMV Thermostatic Mixing Valve has the capacity to service multiple outlets and features a removable cartridge for ease of service. The

More information

ecotec plus New high efficiency condensing combination and system boiler ranges

ecotec plus New high efficiency condensing combination and system boiler ranges ecotec plus New high efficiency condensing combination and system boiler ranges Simply high performance With condensing boilers becoming ever more widely used the need for high performance products that

More information

Zip Hydroboil. Installation and Operating Instructions. Filtered instant boiling water

Zip Hydroboil. Installation and Operating Instructions. Filtered instant boiling water Installation and Operating Instructions Zip Hydroboil Filtered instant boiling water 01552 Zip Hydroboil 1.5 Litre White 01551 Zip Hydroboil 1.5 Litre Stainless Steel 03552 Zip Hydroboil 3 Litre White

More information

UP/UPS-B/UPN Hot Water Service Circulators

UP/UPS-B/UPN Hot Water Service Circulators UP/UPS-B/UPN Hot Water Service Circulators Visions & Values It is the Vision of the Company to achieve our Corporate Mission by providing quality and innovative products and services that give our customers

More information

GEM-C Wireless User & Installation Manual. Revision October Apollo Solar Electric Limited. Documentation

GEM-C Wireless User & Installation Manual. Revision October Apollo Solar Electric Limited. Documentation Documentation GEM-C Wireless User & Installation Manual Revision October 2014 Apollo Solar Electric Limited Contents GEM-C Wireless User Manual 3 Important Safety Information 3 Introduction 4 The GEM-C

More information

Prism Thermostatic Recessed Shower with Integral 2 Outlet Diverter