TECHNICAL SPECIFICATIONS. MEXICO - HCFC PHASE-OUT MANAGEMENT PLAN (HPMP) Stage II EQUIPMENT FOR REFRIGERATION RECLAMATION CENTRES.
|
|
- Stephen Cox
- 5 years ago
- Views:
Transcription
1 27 January 207 TECHNICAL SPECIFICATIONS MEXICO - HCFC PHASE-OUT MANAGEMENT PLAN (HPMP) Stage II EQUIPMENT FOR REFRIGERATION RECLAMATION CENTRES Grant: I. General Background Information and Objective of the Project. Project Objective The Government of Mexico is the first country that has approved both Stage I and Stage II HCFC Phase-out Management Plans (HPMPs) in the consumption sector that help the Government of Mexico to reach compliance with the Freeze in 203, 0% reduction target in 205, 35% reduction by 208, 50% reduction by 2020 and 67.5% reduction in Stage I HPMP of Mexico is addressing mainly the phase-out of HCFC-4b in the foam and appliance manufacturing sectors however, HCFC-4b and HCFC-22 consumption is also addressed in the aerosol/solvents and service sectors. Stage II HPMP focuses on the complete phase-out of HCFC-4b consumption in all sectors as well as on the further reduction of HCFC-22 consumption in the service and aerosol/solvent sectors. These technical specifications focus on the reclamation of refrigerants in centralized operation. Since Recovery, Recycling and Reclaim of refrigerants will be made mandatory by law, it is proposed to upgrade two national HCFC Reclamation Centers selected by the Government of Mexico. The success in establishing and operating of these centers can lead to smoothening of the phase-out of HCFC Expected Outputs Two national HCFC Reclamation Centers upgraded to ensure supply of recovered and reclaimed HCFC-22 to the local servicing market, thereby reducing demand for virgin HCFC-22
2 II. Scope of Supply II. Equipment, parts, supplies to ECOFRIGO company i) Vtech Fast-Charge Refrigerant Cylinder Filling System or Similar (One) For filling with gas refrigerant from bulk tanks (450 and,000 kg) to small cylinders (0 to 60 kg) Stand-alone system for filling one tank at a time Refrigerant type: HCFC, HFC and blends Fully automated system with filling speed of 250 g/s Charging accuracy: +/- % Rotary vane vacuum pump size: 0 m 3 /h Scale with load cell ( specifications and capacity according with the cylinders to fill) Electrical/pneumatic control cabinet Station panel control Instruction manual in Spanish ii) iii) Refrigerant Gas Transfer Pump PTG 300 or Similar (two) One for R-22 and one for R-34a Fully pneumatic with Double Effect Pistons (push and pull), robust and reliable The transfer pump must be suitable to transfer the refrigerant gas from the storage tank to the Fast-Charge Cylinder filling system and must include the hoses, valves and connections With Refrigerant Heads made in anodized l.a. ERGAL and the Refrigerant Cylinders of fully-chromed Carbon Steel To supply the refrigerant gas in Liquid Phase, with a Compression Ratio of the Vapor Pressure (Pv) of 3,85 (Pa), adjustable between and 8 Bar Including fine mesh gas filter, compressed air pressure regulator and filter, 3/8 Quick Connection Inlet and Outlet Ports, and a suitable Nitrogen Pressure Accumulator with Floating Piston Instruction manual in Spanish Gas Chromatograph (GC) Model 860C or Similar (One) Chassis with 6 Channel USB and Peak Simple data system software of windows PC (compatible with windows XP/Vista/7/8/0) With all accessories for determination of purity and composition of reclaimed refrigerant gases according with AHRI Normative Electronic pressure control (EPC) of all GC system gases Pressure-programmable carrier gas LED display of all controlled zones, valve status, temperature, pressure and voltage. Thermal Conductivity Detector (TCD) Flame Ionization Detector (FID) 0 Port Gas Sampling Valve, electric actuator Gas line installation kit, CGA 580 for Helium carrier gas Gas line installation kit, CGA 580 for Nitrogen carrier gas Gas line installation kit, CGA 350 for Hydrogen carrier gas All accessories and connections required to take the sampling from the refrigerant gas and undertake the analysis with Gas Chromatograph for the determination of purity (of R-22 and R34a) and composition of the refrigerant blends (series 400 and series 500) according to Appendix C for Analytical Procedures for AHRI Standard Normative 2
3 Deflected point needle: Standard hub 22 gage X -/2 inch stainless steel Impurities for calibration standard preparation for R-22 R-34a and impurities for calibration standard preparation Swivel union: /4 inch female flare X /4 inch female flare Gas collecting tubes: 4 tubes of 25 ml and 6 tubes of 500 ml. (Enlarged side outlet opening to accommodate a crimp-on 2 cm septum. Fiberglass tape to the outside for protection) 2 Steel cylinders: 2 L, with a single 9 gauge valve 2 Steel cylinder: L, with a single 9 gauge valve 4 Syringes of ml, gas tight The supplier must give instructions for the correct installation of the Gas Chromatograph (GC) and training to use GC to determine the purity of the refrigerant gases R-22 and R-34a and composition of the refrigerant blends (series 400 and series 500) according with the analytical procedures for AHRI Standard Normative. iv) Evacuation and cleaning/drying station for the cylinders ( set) Hot water dispenser supplied with angled lance and rotating nozzle with a dimension allowing insertion in the cylinders through the valve opening, for example: Hot water pressure washer 500STLEF or Similar o Horse power: 3 o Voltage/amperage/phase: 220 Volt/20 Amp/ o Operating pressure in psi/bar: 500/03.5 o Mechanical thermal protection of the pump o Liquid propane burner o Forced air burner technology with electronic ignition, burners designed to achieve 40o Fahrenheit rise in water temperature o Adjustable pressure and adjustable thermostat and pressure popoff o Trigger Gun o Dual wand with side handle and detergent tip Tool for valve removal complete kit including suitable key for cylinder removal and means to fixate the cylinder while removing the valve; Rack for cylinders. Cylinders shall be placed upside-down in order to allow for cleaning with the hot water dispenser. The cylinder rack shall be suitable for cylinder sizes 30, 50 and 00 lbs. The cylinder rack shall include a drip tray and a bucket filter to remove any contaminants from the water; Cylinder drying equipment; Inspection mirror/camera for cylinder internal inspection. Mirror or camera shall have a dimension allowing for insertion into the cylinder through valve opening; Air compressor for testing of recovery cylinders; Industrial vacuum pump; app. 6 m 3 /h; ultimate vacuum level: app. 0-3 mbar; Instruction manual in Spanish v) Reclamation unit with 2HP compressor (one) Suitable for multi-refrigerants use (R-2, R-34a, R-22, R-500, R502, and other refrigerants) Hermetic compressor, 2HP Capable of vacuum operation; Liquid Injection for compressor protection under vacuum operation; Sub-cooling feature; Measurable oil out 3
4 Cylinder overfill protection feature Reclamation capacity 2.3 kg/minute in the liquid phase Storage capacity of 40 kg Pressure gauges ph / 220 volt / 60 hz electric supply Accessories and Spares to be include for each unit: 5 x filter driers set of spare hoses Any other recommended spare and consumables for one year normal use vi) Karl Fisher moisture tester (one) vii) Additional lab equipment 2 x Goetz tubes complete with basic accessories; i.e. heavy stand, suitable sized beaker, clamp etc.; x electronic precision thermometer; range: -80 to 00 o C; accuracy: 0.03 o C; Laboratory scale; Gas tight syringes; viii) Advanced type of identifier to test the quality of the refrigerant (one) Detects R-2, R-22, R-34, most common refrigerants under 400 & 500 series, and hydrocarbons; Digital display shows detected composition; Possibility to connect printer to transfer data to computer (or built-in printer); Complete operating and maintenance instruction in Spanish; Spare parts and consumables for one year of operation as recommended by manufacturer. This should include 0 x sampling filters and 0 filters for the liquid sampling assembly; Other characteristics provided by supplier incl. software updates; ix),000 lbs storage tanks (five),000 lbs recovery tanks with liquid level float switch and 2 valve access separately for liquid and vapor (ERC and DOT approved) suitable for R- 2, R-,R-502 & R-22; x) 00 lbs recovery tanks (ten) 00 lbs recovery tanks with liquid level float switch and 2 valve access separately for liquid and vapor (ERC and DOT approved) suitable for R- 2, R-,R-502 & R-22; xi) 30 lbs recovery cylinders (forty) 30 lbs recovery tanks with liquid level float switch and 2 valve access separately for liquid and vapor (ERC and DOT approved) suitable for R- 2, R-,R-502 & R-22; 4
5 II.2 Equipment, parts, supplies to SILVER BREEZE company i) DRAKE 25 Ton nominal dual circuit Scroll chiller with separate recirculation system or Similar (one) For cooling (air-cooled) and condensation of refrigerant being reclaimed, Packaging and drying process Voltage 220 V/3 Ph/60 Hz Ambient Air 95 deg F Entering Fluid : P. Glycol 55 deg F / Leaving fluid 40 deg F at flow rate 32.8 (GPM) Nominal BTU 300,263 Actual BTU 245,892 PSG Microprocessor Control (CTRL-STD) Evaporator Sized For Glycol (EVAP-UP) Aluminum Fin Condenser (CND-STD) Low Ambient 40 Deg F (LA-STD) High Efficiency Brazed Plate Evaporator (BP-STD) Suction Line Accumulator (s) (SLA-STD) Fused Disconnect and Phase Monitor (FUSE-OPT D500-80) 200 Gallons Stainless Steel Recirculation Tank (TSR200S-SS) psi HP Process Pump with Isolation Ball Valves with Unions. (ISO-STD) psi 3HP Process Pump with Isolation Ball Valves with Unions. (ISO-STD) Tank sight glass Instruction manual in Spanish ii) Gas Chromatograph (GC) Model 860C or Similar (one) Chassis with 6 Channel USB and PeakSimple data system software of windows PC (compatible with windows XP/Vista/7/8/0) With all accessories for determination of purity and composition of reclaimed refrigerant gases according with AHRI Normative Electronic pressure control (EPC) of all GC system gases Pressure-programmable carrier gas LED "at a glance" display of all controlled zones, valve status, digital LED display of temperature, pressure and voltage. Thermal Conductivity Detector (TCD) Flame Ionization Detector (FID) 0 Port Gas Sampling Valve, electric actuator Gas line installation kit, CGA 580 for Helium carrier gas Gas line installation kit, CGA 580 for Nitrogen carrier gas Gas line installation kit, CGA 350 for Hydrogen carrier gas All accessories and connections required to take the sampling from the refrigerant gas and undertake the analysis with Gas Chromatograph for the determination of purity (of R-22 and R34a) and composition of the refrigerant blends (series 400 and series 500) according to Appendix C for Analytical Procedures for AHRI Standard Normative Deflected point needle: Standard hub 22 gage X -/2 inch stainless steel Impurities for calibration standard preparation for R-22 R-34a and impurities for calibration standard preparation Swivel union: /4 inch female flare X /4 inch female flare Gas collecting tubes: 4 tubes of 25 ml and 6 tubes of 500 ml. (Enlarged side outlet opening to accommodate a crimp-on 2 cm septum. Fiberglass tape to the outside for protection) 2 Steel cylinders: 2 L, with a single 9 gauge valve 2 Steel cylinder: L, with a single 9 gauge valve 5
6 4 Syringes of ml, gas tight The supplier must give instructions for the correct installation of the Gas Chromatograph (GC) and training to use GC to determine the purity of the refrigerant gases R-22 and R-34a and composition of the refrigerant blends (series 400 and series 500) according with the analytical procedures for AHRI Standard Normative. iii) EVAC High Pressure Electromechanical Commercial Recovery System (REF TEC) with cleaning module or Similar (one) To service chillers and other large cooling systems Services R2, R22, R34a, R502 & other high pressure refrigerants Application: On site portable refrigerant recovery Minimum Recovery Rate 324 lb/min (R22 liquid) and 6lb/min (vapour) to service chillers & other large cooling systems Voltage 220 V/ Ph/60 Hz 5 Amps Air cooled condenser Final vacuum 5 Hg AHRI 700 certified 3 HP single phase,725 RPM electric motor Open drive reciprocating compressor Actuated valving system and electromechanical controls 48 cubic inch dryer core to remove moisture, acids and particulates Connections ¾ flare with ball valves 00-ft power cords for controls (3 Phase only) 50-ft power cord for the system 2 ft tank float cable 3 pin BH 2 of ¾ x 0 ft refrigerant hoses and 2 of ¾ x 20 ft hose Instruction manual in Spanish Suggested additional requirements: o Built-in low pressure / high pressure gauges o Replaceable inlets filters o Self-evacuating to ensure refrigerants are not mixed when changing refrigerant o Protection against overpressure o Thermal overload protection o Cylinder overfill protection o The recovery unit should be delivered with an external cleaning module comprising oil-separator with draining capability as well as a filter drier. All necessary hoses required to operate the recovery unit AND the cleaning module should be supplied. o Two copies of complete operating and maintenance instructions (Spanish) Accessories and Spares to be include for each unit: o 5 x Replaceable inlet filters for unit & cleaning module o x Sight glass o 2x Spare pressure gauges o Any other recommended spare and consumables for one year normal use iv) LOVAC Low Pressure Commercial Recovery System (REF TEC) with cleaning module or Similar (one) For low pressure chillers and other large cooling systems To service R, R-3, R-23, R-4 & other low pressure refrigerants Application: On site portable refrigerant recovery (liquid and vapour transfer) 6
7 Minimum Recovery Rate 00 lb/min (R liquid) and 0.66lb/min (vapour) Voltage 220 V/ Ph/60 Hz 5 Amp Electromechanical water-cooled condenser Final vacuum 29 Hg AHRI 700 certified 2 HP single phase,725 RPM electric motor Open drive compressor 3 Way hand valves and rerouting Hoses 48 cubic inch dryer core to remove moisture, acids and particulates Connections ¾ flare or optional quick connects 50-ft power cord for the system 2 ft tank float cable 3 pin BH 2 of ¾ x 0 ft refrigerant hoses and 2 of ¾ x 20 ft hose with ball valves Low pressure cut off switch 29 Hg Instruction manual in Spanish Suggested additional requirements: o Built-in low pressure / high pressure gauges o Replaceable inlets filters o Self-evacuating to ensure refrigerants are not mixed when changing refrigerant o Protection against overpressure o Thermal overload protection o Cylinder overfill protection o The recovery unit should be delivered with an external cleaning module comprising oil-separator with draining capability as well as a filter drier. All necessary hoses required to operate the recovery unit AND the cleaning module should be supplied. o Two copies of complete operating and maintenance instructions (Spanish) Accessories and Spares to be include for each unit: o 5 x Replaceable inlet filters for unit & cleaning module o x Sight glass o 2x Spare pressure gauges Any other recommended spare and consumables for one year normal use v) Enviropurge HP Portable, Air/Water cooled (REF TEC EHP-6) Purger or Similar (one) Application: Removes non-condensable gases from high pressure refrigerants to service chillers, large cooling systems and storage refrigerant tanks Power requirements: 20V/60Hz/Ph/30 Amps Air or Water cooled condenser Discharge efficiency as high as 0.2 lbs/refg/lbs-non-condensable ETL, CE, CSA and EPA compliant and UL HP semi hermetic compressor with internal overload and microprocessor controls Aluminum or steel portable cart on wheels 48 cubic inch dryer core to remove moisture, acids and particulates (20 pieces) /2 and 3/8-inch flare connections and shut off valves Services R-2, R-34a, R-22, and R-502 refrigerants 25-ft power cord for the system 2 Isolation valves 7
8 piece of 20 ft x ½-inch refrigerant hoses and piece of 20 ft x 3/8- inch hoses Low pressure cut off switch 29 Hg Instruction manual in Spanish vi) Corken Industrial Gas High Speed High Volume In House Refrigerant Recovery Compressor or Similar (one) Application: Refrigerant Reclaiming Process Unit Power requirements: 220V/Ph/ 60 Hz/7amps Discharge efficiency as high as 300lbs/refg/hr 3 HP/ 740 RPM motor Constructed welded steel base, adjustable motor slide base 3/4-inch inlet/outlet connections and shut-off valves Services R-2, R-34a, R-22, and series 500 refrigerants S-7057 Vertical Refrigerant Accumulator /8 Helical oil separator Temprite 900 series oil separator 7/8 Vertical Refrigerant Accumulator 00 cubic-inch desiccant block filter dryer 20 psi inlet regulating valve Instruction manual in Spanish. vii) Refrigerant Recovery Tanks (five) Capacity:,000 lbs ¾ ports Connections 3/4" Flare ball valves Cover the Standard DOT for high pressure refrigerants and blends (R- 22, R-34a and Series 500 and Series 400) viii) Evacuation and cleaning/drying station for the cylinders ( set) Hot water dispenser supplied with angled lance and rotating nozzle with a dimension allowing insertion in the cylinders through the valve opening; Tool for valve removal complete kit including suitable key for cylinder removal and means to fixate the cylinder while removing the valve; Rack for cylinders. Cylinders shall be placed upside-down in order to allow for cleaning with the hot water dispenser. The cylinder rack shall be suitable for cylinder sizes 30, 50 and 00 lbs. The cylinder rack shall include a drip tray and a bucket filter to remove any contaminants from the water; Cylinder drying equipment; Inspection mirror/camera for cylinder internal inspection. Mirror or camera shall have a dimension allowing for insertion into the cylinder through valve opening; Air compressor for testing of recovery cylinders; Industrial vacuum pump; app. 6 m 3 /h; ultimate vacuum level: app. 0-3 mbar; Instruction manual in Spanish ix) Reclamation unit with 2HP compressor () Suitable for multi-refrigerants use (R-2, R-34a, R-22, R-500, R502, and other refrigerants) Hermetic compressor, 2HP Capable of vacuum operation; Liquid Injection for compressor protection under vacuum operation; Sub-cooling feature; 8
9 Measurable oil out Cylinder overfill protection feature Reclamation capacity 2.3 kg/minute in the liquid phase Storage capacity of 40 kg Pressure gauges ph / 220 volt / 60 hz electric supply Accessories and Spares to be include for each unit: 5 x filter driers set of spare hoses Any other recommended spare and consumables for one year normal use x) Karl Fisher moisture tester (one) xi) Additional lab equipment 2 x Goetz tubes complete with basic accessories; i.e. heavy stand, suitable sized beaker, clamp etc.; x electronic precision thermometer; range: -80 to 00 o C; accuracy: 0.03 o C; Laboratory scale; Gas tight syringes; xii) Advanced type of identifier to test the quality of the refrigerant (one) Detects R-2, R-22, R-34, most common refrigerants under 400 & 500 series, and hydrocarbons Digital display shows detected composition Possibility to connect printer to transfer data to computer (or built-in printer) Complete operating and maintenance instruction in Spanish; Spare parts and consumables for one year of operation as recommended by manufacturer. This should include 0 x sampling filters and 0 filters for the liquid sampling assembly. Other characteristics provided by supplier incl. software updates xiii) 00 lbs recovery tanks (ten) 00 lbs recovery tanks with liquid level float switch and 2 valve access separately for liquid and vapor (ERC and DOT approved) suitable for R- 2, R-,R-502 & R-22 xiv) 30 lbs recovery cylinders (forty) 30 lbs recovery tanks with liquid level float switch and 2 valve access separately for liquid and vapor (ERC and DOT approved) suitable for R- 2, R-, R-502 & R-22 III. Guarantee Requirements The supplier should give guarantee for at least one year after delivery, installation, commissioning and training of the equipment. IV. Delivery Period As soon as possible, but within maximum 4 months arrival at the beneficiary (DAP). 9
10 V. Additional requirements The suppliers shall: Provide, in Spanish language, technical advice and detailed requirements for the site preparation, proper installation and operation of the equipment. Provide, in Spanish language, theoretical and practical training on the operation and preventive maintenance of the equipment at the beneficiaries sites. Quote spare parts and consumables for one year of operation for all above items. Have a representative office in the country and administrative and technical personnel to give technical support and to repair defective equipment. Warrant during 2 months that goods supplied under the contract shall be free from defects. The supplier shall repair or replace at his own expense and as soon as practicable any defective goods within the warranty period. Provide, in Spanish language, all instructions, manuals, rules and recommendations to operate the equipment (at least two manuals for each item). Warrant the availability of spare parts and equipment for a minimum period of four years. 0
11 ANNEX I Scope of Supply UNIDO RFP Reference No. Scope of supply UNIDO REQUIREMENTS Item Name and required parameters Qty II.. Equipment, parts, supplies - ECOFRIGO i VTech Fast-Charge Refrigerant Cylinder Filling System or Similar ii Refrigerant Gas Transfer Pump PTG300 or Similar 2 iii Gas Chromatograph (GC) 860C or Similar iv Evacuation and cleaning/drying station for the cylinders set v Reclamation unit with 2HP compressor vi Karl Fisher moisture tester vii Additional lab equipment set Advanced type of identifier to test the quality of the viii refrigerant ix,000 lbs storage tanks 5 x 00 lbs recovery tanks 0 xi 30 lbs recovery cylinders 40 TO BE COMPLETED BY THE INVITEE unit price total item price Complia nce US$ US$ yes/no Remark s**) II.2. Equipment, parts, supplies SILVER BREEZE i DRAKE 25 Ton nominal dual circuit Scroll chiller with separate recirculation system or Similar ii Gas Chromatograph (GC) 860C or Similar iii iv v vi EVAC High Pressure Electromechanical Commercial Recovery System (REF TEC) with cleaning module or Similar LOVAC Low Pressure Commercial Recovery System (REF TEC) with cleaning module or Similar Enviropurge HP Portable, Air/Water cooled (REF TEC EHP-6) or Similar Corken Industrial Gas High Speed High Volume In House Refrigerant Recovery Compressor or Similar vii Refrigerant recovery tanks (,000 lbs) 5 viii Evacuation and cleaning/drying station for the cylinders ix Reclamation unit with 2HP compressor x Karl Fisher moisture tester set xi Additional lab equipment set xii Advanced type of identifier to test the quality of the refrigerant xiii 00 lbs recovery tanks 0 xiv 30 lbs recovery cylinders 40 III. Cost of transportation & insurance Total price:
12 ECOFRIGO, S.A. DE C.V. 2 ANNEX II - Delivery details and addresses RRR Centre ADDRESS CONTACT PERSON TELEPHONE/ SILVER BREEZE- CENTRO DE RECICLADO DE REFRIGERANTES Carretera Celaya Salvatierra Km. 6.5, Rancho Santa María del Refugio Celaya, Guanajuato México Luis de Velazco 50, Colonia Vista Hermosa Mexicali, Baja California México Mr. Antony Lozano Mr. Agustín Quintana +52 (55) and antony@ecosave.com.mx and antonyicaza@gmail.com +52 (686) and aquintana@silverbreezei.com 2
REFRIGERANT RECOVERY DEVICES AND ACCESSORIES
DEVICES AND ACCESSORIES DEVICES AND ACCESSORIES PROMAX RECOVERY DEVICES PROMAX designs, engineers, and manufacturers the highest quality service equipment and makes it easy to use for all refrigerant handling
More informationOPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS MODEL LV20 LARGE CAPACITY REFRIGERANT RECOVERY UNIT NATIONAL REFRIGERATION PRODUCTS 985 WHEELER WAY LANGHORNE, PA 19047 (215) 638-8909 FAX (215) 638-9270 R01101 LV20.DOC NRP-OM-LV20
More informationMAC N-407 Air-Cooled Chiller
MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=
More information60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES
60 TON AIR-COOLED CHILLER PA-ACCTR-60 Call us today! (800)341-4297 The 60-Ton portable chiller package features a Trane CGAM chiller unit. Trane leads the industry in providing some of the most reliable,
More informationRefrigerant Recovery Unit, Model RRU134
Installation, Operation & Maintenance Manual IOMM RRU134 Group: Refrigerant Effective: December 2000 Supersedes: New Refrigerant Recovery Unit, Model RRU134 1999 McQuay International Table of Contents
More informationMACH N-407 Heat Pump Air-Cooled Chiller
MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type
More informationRecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual
RecoverX Oil-Filled Hermetic Refrigerant Recovery System Operation and Maintenance Manual Table of Contents Page General Safety Instructions 2-3 System Overview 3 Operating Guide 4 Restart Procedure 4
More informationOperation and Maintenance Manual
Warranty Information Ritchie Engineering guarantees YELLOW JACKET products to be free of defective material and workmanship which could affect the life of the product when used for the purpose for which
More informationENSPECO Recovery/ Recycle/ Evacuate/ Recharge
ENSPECO Recovery/ Recycle/ Evacuate/ Recharge RMS 3012 RMS 3034 Approved by UL/SAE to J-1991 R12 Purity Standards Approved by UL/SAE to J-2210 R134 Purity Standards This semi-automatic machine will recover
More informationMAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.
MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient
More informationMAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.
MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient
More information100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION
100 TON AIR-COOLED SCROLL PACKAGED SPECIFICATIONS Call us today! (800)341-4297 Trane Portable Packaged Air Conditioner units contain the best compressor technology available, in order to achieve the highest
More informationOPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS MODEL LV8 COMMERCIAL REFRIGERANT RECOVERY UNIT NATIONAL REFRIGERATION PRODUCTS 985 WHEELER WAY LANGHORNE, PA 19047 (215) 638-8909 FAX (215) 638-9270 A01001 7/11/96 NRP-OM-LV8 7/96
More informationMAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.
MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.2 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient
More informationCall us today! (800)
PA-ACCTR-200 Call us today! (800)341-4297 The 200-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable, efficient and quiet chiller
More information500 EX Fusion Compressor Series
500 EX Fusion Compressor Series R404A M/T R404A L/T Capacity RANGE 13.8kW - 20.4kW 7.7kW -11.2kW Copeland Fusion Semi-Hermetic Horizontal Scroll Compressors For Medium and Low Temperature Applications
More informationCall us today! (800)
500 TON AIR-COOLED CHILLER PA-ACCTR-500 Call us today! (800)341-4297 The 500-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,
More informationTITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F
Temperature Control Units Water & Oil - F Portable Chillers Air & Water-Cooled - 7 F Central Chillers Air & Water-Cooled Packages & Modules - 7 F Pump Tank Stations Chilled or Tower Water - gallons Cooling
More informationa. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system
Core 1. Ozone in the stratosphere above the earth consists of: a. Molecules containing 3 oxygen atoms. b. Molecules of 2 oxygen atoms. c. Radioactive particles. d. Pollutants that have risen from ground
More informationORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS
ORTEC Compressed Air, Gas & Fluid Technologies HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS Energy Lean Planet Green Cycling and Non-Cycling Design Energy Efficient s Fluctuating and Intermittent Loads Capacity,0
More informationORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.
ORTEC Compressed Air, Gas & Fluid Technologies t a l r o n m e n i l y E n v F r i e n d t r a n l y R e i g e f r INDUSTRIAL FLUID CHILLERS FC SERIES (0-00 TONS) Application Flexibility Nortec Industrial
More informationCall us today! (800)
150 TON AIR-COOLED CHILLER PA-ACCTR-150 Call us today! (800)341-4297 The 150-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,
More informationOWNER S MANUAL (English)
TR600 Series Refrigerant Recovery Machines OWNER S MANUAL (English) Français, Español, Deutsch and latest updates: www.cpsproducts.com Series: TR600, TR610, TR600C, TR610C, TR600S, TR600K, TR600E TO BE
More informationSome of these procedures need to be performed to conform to requirements of the Clean Air Act.
Leak Detection, Recovery, Evacuation and Charging Four basic service procedures used to repair and maintain a mechanical refrigeration system are leak detection, evacuation, recovery, and refrigerant charging.
More informationOPER LV Wheeler Way
OPER RATING INSTRUCTIONS LV5 REFRIGERANT RECOVERY UNIT NATIONAL REFRIGERATION PRODUCTS 985 Wheeler Way Langhorne, PA 19047 Ph:(215) 638-8909 9 info@ @nrproducts.com LV5.DOC 9.17.2018 MODEL LV5 REFRIGERANT
More informationRefrigerant Recovery Machine. Model No Operating Manual
Refrigerant Recovery Machine Model No. 25700 Operating Manual Safety Precautions WARNING : TO PREVENT PERSONAL INJURY AND / OR EQUIPMENT DAMAGE, CAUTION - Risk of injury. This equipment should only be
More informationa. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system
Core 1. Ozone in the stratosphere above the earth consists of: a. Molecules containing 3 oxygen atoms. b. Molecules of 2 oxygen atoms. c. Radioactive particles. d. Pollutants that have risen from ground
More information14. The center port of the manifold is used for evacuation, charging and refrigerant recovery.
HET- 190 ESL Support page 1 CORE Basic Refrigeration Circuit 1. Liquid refrigerant boils in the evaporator. Heat is absorbed. The heat energy absorbed converts refrigerant liquid into vapor. 2. Refrigerant
More informationMAC-120HE-03 Air-Cooled Chiller
MAC-120HE-03 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 380/415/460-3-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-03
More informationB. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).
Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage
More informationSPECIFICATIONS MODEL E859C MINI DEHYDRATOR
SPECIFICATIONS MODEL E859C MINI DEHYDRATOR 1 DEHYDRATION TECHNOLOGY This proposal describes the equipment which shall be supplied by ENERVAC for a system for processing (dehydrating, de-aerating, purifying
More informationAIR CONDITIONNING 95 CODE 002
CODE 002 AIR CONDITIONNING 95 Cool-Tech Refrigerant Recovery/Recycling Unit Model 34788 It recovers, recycles, evacuates, leak tests, and recharges R-134a quickly and accurately. Fully automatic function
More informationSECTION REFRIGERATION. 1. Reciprocating Compressors (Hermetic). 2. Reciprocating Compressors (Open Drive). 3. Water Cooled Condensing Units.
SECTION 15650 REFRIGERATION PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Reciprocating Compressors (Hermetic). 2. Reciprocating Compressors (Open Drive). 3. Water Cooled Condensing Units. 4. Air
More informationTRS21 IGNITION PROOF SERIES
TRS21 IGNITION PROOF SERIES 2 Cylinder Commercial Recovery Machine OWNER S MANUAL (English) Français, Español, Deutsch and latest updates: www.cpsproducts.com Series: TRS21, TRS21C, TRS21S Evaluated for
More informationProduct Data. Features/Benefits. 19XB Positive Pressure Storage System
Product Data 19XB Positive Pressure Storage System 19XB028 Copyright 1992 Carrier Corporation 19XB052 Carrier s Positive Pressure Storage (PPS) System ensures the critical conservation of refrigerants
More informationThomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.
Thomas J Kelly Sr. Engineering Instructor Carrier Corporation August 20, 2003 1 SESSION OBJECTIVES At the conclusion of this session you should be able to: 1. Describe the basics principles of refrigeration
More informationTemptek Auxiliary Equipment
Temptek Auxiliary Equipment Mold Temperature Controllers - Water Units VT-275-LX VT Series Mold Temperature Controllers are used to process temperature control to 250 F. These units use an incoloy heater
More informationSMALL AIR COOLED CONDENSERS
Catalog KM-KDX-0816A Supersedes Catalog KM-KDS-1014A UNICON SMALL AIR COOLED CONDENSERS 2 Unicon Efficient and Reliable Kramer s Remote Air Cooled Condensers innovative design provides a wide array of
More informationSECTION 50 - CAB CLIMATE CONTROL
AIR CONDITIONING SYSTEM DYNAMIC DESCRIPTION The refrigerant circuit of the air conditioning system contains five major components: Compressor, Condenser, Receiver/Drier, Expansion Valve, and Evaporator.
More informationSTACT. Model Designations. Model Number: STACT8S6. ST = Portable Scroll Chiller. AC = Air Cooled WC = Water Cooled. T = With Process Tank
A C P S C STACT Model Designations Model Number: STACT8S6 ST AC T ST = Portable Scroll Chiller AC = Air Cooled WC = Water Cooled T = With Process Tank 8 8 = Model Size* S 6 XP / LT S = Single Refrigeration
More information30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw
Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The
More informationcussons Refrigeration Assembly Range TECHNOLOGY REFRIGERATION AND AIR CONDITIONING CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION
REFRIGERATION AND AIR CONDITIONING CUSSONS LABORATORY RECOMMENDATION Cussons Refrigeration laboratories are offered to provide teaching to a range of different skill levels. In all the laboratories teaching
More informationRefrigerant Recovery/Recharging Series
TrustworthyBrandChinaChunMu Refrigerants TrustworthyBrandChinaChunMu 2012 Refrigerant /Recharging Series Portable Refrigerant /Recharging Unit Light Commercial HVAC Industrial Refrigeration System Automotive
More informationC. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.
SECTION 236426 - ROTARY-SCREW WATER CHILLERS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, water cooled or air cooled as scheduled, electric-motor-driven, rotary-screw water chillers
More informationCalhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration
Calhoon MEBA Engineering School Study Guide for Proficiency Testing Refrigeration 1. To prevent an injury when working with refrigerants, what safety precautions are necessary? 2. When halogens are in
More informationDESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6
DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6 1.1. REFERENCE STANDARDS 1.2. GENERAL 1.1.1. The units shall be listed by Electrical Testing Laboratories (ETL) and bear the ETL label. 1.1.2.
More informationPreventative Maintenance Tables
Preventative Maintenance Tables Table of Contents I. Table : Gas Fired Domestic Hot Water Heater II. III. IV. Table : Circulating Pump Table : Convectors Table 4: Grille and Diffusors V. Table 5: Unit
More informationCERTUS 11 / 12 EVACUATION & REFRIGERANT CHARGING EQUIPMENT FOR FLAMMABLE GASES
CERTUS 11 / 12 EVACUATION & REFRIGERANT CHARGING EQUIPMENT FOR FLAMMABLE GASES GALILEO TP PROCESS EQUIPMENT S.r.l. Via del Pantano 73 50018 Scandicci (Firenze) Italia Tel. (+39) 055 7221358 Fax (+39) 055
More informationMASS. MARITIME ACADEMY
MASS. MARITIME ACADEMY REFRIGERATION LAB OUTLINE Rev.3 Fall 2015 Table of Content Page Lab #1: Introduction to refrigeration system components, tools and procedures 1 Lab #2: Familiarization, operation,
More informationREFRIGERANT RECOVERY SYSTEMS
REFRIGERANT RECOVERY 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com RECOVERY YELLOW JACKET HVAC&R HOSES YELLOW JACKET YJ-LTE Refrigerant
More informationOPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS MODEL RLV-700 REFRIGERANT RECOVERY / RECYCLING UNIT (PATENTED) NATIONAL REFRIGERATION PRODUCTS 985 Wheeler Way Langhorne, PA 19047 (215) 638-8909 FAX (215) 638-9270 REVISED 03-21-2018
More informationFluid Exchange. Refrigerant Handling Systems Recovery/Recycling Systems Fluid Exchangers Flushers Fluid Exchange Accessories BUYER'S GUIDE
Fluid Exchange Refrigerant Handling Systems Recovery/Recycling Systems Fluid Exchangers Flushers Fluid Exchange Accessories 423 ASCOT 424 Refrigerant Recovery/Recycling Systems Recovery and Recycling Systems
More information347002K/177002K/34900
Service Manual Models: 347002K/177002K 34900/347012K Manifold Block Style Recovery/Recycling/Recharging Unit For R-12 or R-134a Only TABLE OF CONTENTS: Theory of Operation and Safety Precautions... 2 Depressurizing
More informationKITS COMMON TO HEATING AND COOLING EQUIPMENT 504,652M 03/04. Supersedes 503,249M
2004 Lennox Industries Inc. Dallas, Texas KITS COMMON TO HEATING AND COOLING EQUIPMENT 504,652M 03/04 Supersedes 503,249M Litho U.S.A. COMPRESSOR REPLACEMENT KIT INSTALLATION INSTRUCTIONS FOR COMPRESSOR
More informationRECORD SUBMITTAL COVER SHEET
RECORD SUBMITTAL COVER SHEET PROJECT TITLE: AXCELLERATE PHARMA EQUIPMENT DESCRIPTION: CARRIER AQUASNAP AIR-COOLED CHILLER CH-1 OWNER: AXCELLERATE PHARMA MECHANICAL ENGINEER: ARDEN DATE: JUNE 27, 2014 SUBMITTED
More information4201 Lien Rd Madison, WI Owner s Manual Therma-Stor III Heat Recovery System. Installation, Operation & Service Instructions
4201 Lien Rd Madison, WI 53704 TS-140F Revised 09-10 Owner s Manual Therma-Stor III Heat Recovery System Installation, Operation & Service Instructions Read and Save These Instructions Table Of Contents
More informationVERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System
VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System PART 1 SYSTEM DESCRIPTION 1.1 The HVAC system is based on the CGC HYBRID Hydronic Heat Pump System. 1.2 The system will automatically
More informationVHP ARD BIODECONTAMINATION SYSTEM
VHP ARD BIODECONTAMINATION SYSTEM APPLICATION The VHP ARD Biodecontamination System is designed for portable biodecontamination* of clean, dry, sealed Enclosures.** The VHP 1000-ARD Biodecontamination
More informationSLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual
u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications
More informationRetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)
Indoor Single Package Vertical, Air-Cooled Heat Pump Unit RetroAire Model Number: Capacity Range: VPRH 9,000 to 36,000 Btuh (2.6 to 10.5 kw) Part 1 General 1.01 UNIT DESCRIPTION A. Indoor, single package
More informationINSTRUCTIONS RHS 700. Recovery, Recycling, Evacuation and Charging Station RHS 700
A GRAMKOW A/S Augustenborg Landevej 19 DK-6400 Sønderborg Denmark A/S Reg. No. 17 12 31 Telephone: 45 74 12 36 36 Telefax: 45 74 43 36 46 Telex: 5 23 18 Bank: Den Danske Bank, No. 32 27 INSTRUCTIONS Recovery,
More informationLABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS
SECTION 22 20 00 LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements",
More informationSECTION ROTARY-SCREW WATER CHILLERS
PART 1 GENERAL 1.01 SECTION INCLUDES A. Factory-assembled packaged chiller. B. Charge of refrigerant and oil. C. Controls and control connections. D. Chilled water connections. E. Electrical power connections.
More informationDriven by CLIMATISATION. Excellence for professionals. Bosch air conditioning service units for R-134a and R-1234yf
Driven by CLIMATISATION Excellence for professionals Bosch air conditioning service units for R-134a and R-1234yf A/C service from Bosch Air conditioning systems in vehicles require regular maintenance.
More informationTRS21 IGNITION PROOF SERIES
TRS21 IGNITION PROOF SERIES 2 Cylinder Commercial Recovery Machine OWNER S MANUAL (English) Français, Español, Deutsch and latest updates: www.cpsproducts.com Series: TRS21A, TRS21E TO BE OPERATED BY QUALIFIED
More information.2 Section Waste Management and Disposal.
Issued 2005/06/01 Section 15624 Packaged Rotary Screw Water Chillers Page 1 of 5 PART 1 General 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3
More informationOPERATION & MAINTENANCE MANUAL TX600
OPERATION & MAINTENANCE MANUAL TX600 RTI TECHNOLOGIES, INC. 4075 East Market Street York, PA 17402 Manual P/N 035-80118-00 (Rev B) ! TABLE OF CONTENTS! TX600 Before Using Page 2 Safety Precautions Page
More informationSpaceKeeper Console (SKC)
SpaceKeeper Console (SKC) With finished cabinet or custom enclosure SKC 008-015 ¾ - 1¼ tons 12 W x 25¼ H x 48 L CGC-09 SpaceKeeper Console R410A MODEL NO. SKC _ 008 010 012 015 Net Cooling Capacity - Rated
More informationOACS Outdoor Air-Cooled Central Chillers
OACS Outdoor Air-Cooled Central Chillers Proudly Made In The USA since 1977 A Complete Central Chiller System Complete Central Chiller system with Integrated Reservoir and Pump all mounted on a single
More informationRefrigeration Supplies
Section 11 Refrigeration Supplies INDEX Refrigerant.. 11-2 R-410A. 11-2 HOT-SHOT by ICOR.. 11-2 NU-22b by ICOR. 11-2 Recovery Service 11-2 Recovery Tanks. 11-2 608 Certification. 11-2 Supplies Filter Driers.
More informationariazone 601HD Refrigerant Recovery & Recycling Unit User's manual
ariazone 601HD Refrigerant Recovery & Recycling Unit User's manual Model: Ariazone 601 HD Serial No: 1 1. SAFETY FIRST! Important safety information's - Read this user manual carefully before operating
More informationOWNER S MANUAL (English)
TRS600 IGNITION PROOF SERIES Refrigerant Recovery Machines OWNER S MANUAL (English) Français, Español, Deutsch and latest updates: www.cpsproducts.com Series: TRS600, TRS600K, TRS600S Evaluated for performance
More informationa. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system
Core 1. Ozone in the stratosphere above the earth consists of: a. Molecules containing 3 oxygen atoms. b. Molecules of 2 oxygen atoms. c. Radioactive particles. d. Pollutants that have risen from ground
More informationEPCE00-10B. Powerful. air cooled. Hydronic systems EUWA*40-200K(A)X
EPCE00-10B Powerful air cooled Hydronic systems EUWA*40-200K(A)X Development Environment Technology 2 Daikin s pre-eminent position in air conditioning and chiller production has been built on over 70
More informationPACKAGED AIR COOLED Product Data Catalog
PACKAGED AIR COOLED Product Data Catalog MODELS ASP-10A ASP-15A ASP-20A ASP-00P ASP-00F ASP-00G A MEMBER OF MARDUK HOLDING COMPANY, LLC The Leader in Modular Chillers ETL and CSA Approved CHILLER MODULES
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -
More informationChillers CA Series: 35º 55º LCT CF Series: 35º 55º LCT CE Series: 35º 55º LCT CLH Series: 15º -15º LCT CLM Series: -10º -70º LCT
Products Chillers CA Series: 35º 55º LCT CF Series: 35º 55º LCT CE Series: 35º 55º LCT CLH Series: 15º -15º LCT CLM Series: -10º -70º LCT s s s s s CA-10-W CA-10-R CF-3-W CF-3-A CE-3-W CE-3-A CLH-6-W CLH-3-A
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING
More informationSECTION AIR COMPRESSORS AND ACCESSORIES
PART 1 GENERAL 1.01 WORK INCLUDED SECTION 11370 AIR COMPRESSORS AND ACCESSORIES A. This specification includes air compressors with air dryers. B. Furnish, install, start-up, and test air compressors and
More informationAriazone 601HD Refrigerant Recovery&Recycling unit
Automotive Air-Conditioning Service Equipment Ariazone 601HD Refrigerant Recovery&Recycling unit OPERATOR MANUAL 1 1. SAFETY FIRST! Important safety information's - Read this user manual carefully before
More informationSECTION REFRIGERATION EQUIPMENT. A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories.
SECTION 15650 REFRIGERATION EQUIPMENT PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories. B. Related Section: 1. 11400
More informationCaresaver Universal Refrigerant Recovery Unit
Operation Manual Caresaver Universal Refrigerant Recovery Unit 2 CONTENTS CHAPTER 1 INTRODUCTION AND OVERVIEW Specifications 3 Health and Safety 4-5 Component Location and Identification 6-9 CHAPTER 2
More information30GN FLOTRONIC II AIR-COOLED CHILLERS
30GN-19SB 30GN040-110 FLOTRONIC II AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GN-19SB Supersedes 30GN-6SB, 30GN-7SB, 30GN-8SB, Printed
More informationTECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703
TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.
More informationREFRIGERATION PRODUCTS
REFRIGERATION PRODUCTS Product Catalog REFRIGERATION PRODUCTS PAUL MUELLER COMPANY Table of Contents 3 x 5 Falling Film Chiller.................................... 1 4 x 8 Falling Film Chiller...................................
More informationAir-Cooled Condensing Units with Compact Screw Compressors
LK-SCUTB March 2015 Air-Cooled Condensing Units with Compact Screw s Technical Bulletin Models SSV DSV Table of Contents Nomenclature Chart... 2 Introduction... 3 Bitzer TM s... 4 Magnum TM Microprocessor...
More informationGIRTON CABINET WASHER MODEL 794A
DESCRIPTION GIRTON CABINET WASHER MODEL 794A The washer shall be a Girton Model 794A Cabinet Type Pressure Washer constructed of type-304 stainless steel, utilizing a reciprocating header spray system.
More informationREFRIGERATED AIR DRYERS
QUINcy qpcd series CYCLING QUINcy qpnc series NON-CYCLING REFRIGERATED AIR DRYERS QPCD CYCLING DRYER, QPNC NON-CYCLING Cycling and non-cycling designs for maximum system efficiency Balanced refrigeration
More informationR100 Oil-Less Refrigerant Recovery Unit
R100 Oil-Less Refrigerant Recovery Unit Operation Manual 1 INTRODUCTION Welcome to simple, efficient refrigerant recovery with your new YELLOW JACKET Refrigerant Recovery Unit, R100. This unit combines
More informationSERVICE MANUAL FOR MODEL RM-10
SERVICE MANUAL FOR MODEL RM-10 REQUIRED TOOLS CORDLESS DRILL COPPER CUTTING TUBE 1/2 OPEN WRENCH SOLDERING IRON SCREWDRIVER SET WITH 9/32 SOCKET VISE GRIP PIERCING VALVE PRECISION FLAT BLADE SLOTTED SCREWDRIVER
More informationInstallation, Start-Up and Service Instructions
38AH044-134 Air-Cooled Condensing Units 50/60 Hz Installation, Start-Up and Service Instructions CONTENTS Page SAFETY CONSIDERATIONS...................... 1 INSTALLATION................................
More informationProduct Data Sheet Refrigerant Dryer DFLO-ES 66 (-W) to DFLO-ES 660 (-W) with energy saving management
Product Data Sheet Refrigerant Dryer -ES 66 (-W) to -ES 660 (-W) with energy saving management Version: 1.6.0 Author: Karsten Unger Datum: 05.07.2016 Field of application Refrigeration dryers of the -ES
More informationIsotemp. Improve the productivity of your laboratory with accurate, efficient temperature control products from Fisher Scientific.
Isotemp Bath Circulators and Chillers Improve the productivity of your laboratory with accurate, efficient temperature control products from Fisher Scientific. Choose the temperature control option that
More informationInstallation, Start-Up and Service Instructions
38AH044-134 Air-Cooled Condensing Units 50/60 Hz Installation, Start-Up and Service Instructions CONTENTS Page SAFETY CONSIDERATIONS...................... 1 INSTALLATION................................
More informationTo request a quote or locate your nearest dealer, contact Customer Care toll-free in the US at or
Sample Prep System J2 Scientific introduces the ultimate flexibility and automation for the sample prep lab. The PrepLinc Platform Automated Sample Preparation System offers the ability to combine common
More information30GT FLOTRONIC AIR-COOLED CHILLERS
30GT-41SB 30GT040-110 FLOTRONIC AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GT-41SB Supersedes 30GT-21SB, 30GT-22SB, 30GT-23SB, Printed
More informationManifold Gauge LD.R1.02 LD.R1.01. manifold gauge. manifold gauge. brass body. brass body LD.R1.04 LD.R1.03. manifold gauge.
Manifold Gauge LD.R1.01 manifold gauge brass body LD.R1.02 manifold gauge brass body LD.R1.03 manifold gauge aluminum body LD.R1.04 manifold gauge aluminum body LD.R1.05 manifold gauge aluminum body LD.R1.06
More informationC13-Series Engineering Guide
Engineering Guide Effective January 2018 Horizontal Air-Cooled, Water-Cooled, Chilled Water and Heat Pump Contents Product Features............................... 3 Product Options................................
More informationPower Units & Test Systems
Advanced Air Driven Power Units Power Units & Test Systems Sprague Products Division of Curtiss-Wright Flow Control Corporation TECHNOLOGY THAT CHANGES EVERYTHING Air Driven Power Units Choose an air driven
More information