M/1700; 5/2 & 5/3 Solenoid and pilot actuated spool valves
|
|
- Elfreda Rice
- 5 years ago
- Views:
Transcription
1 M/700; / & / > > Port size: G/8... G Sub-base mounted > > Rugged, well proven range of valves > > Simple to service > > Ideal for control of large cylinders > > Ideally suited to heavy duty applications in harsh environments > > G port size - with integral high flow silencer Technical features Medium: Compressed air, filtered, lubricated or non-lubricated Operation: Spool valves, solenoid pilot or air pilot actuated Mounting: On sub-bases Port sizes: G/8, G/, G/ or G Electrical details for solenoid operators Maximum operating pressure: Solenoid pilot actuated valves... 0 bar (9... psi), bar (9... psi) or... 0 bar (... psi) depending on solenoid pilot operator Air pilot operated valves:... 0 (9... psi) Refer to technical specification table for details Voltage tolerance ± 0% Rating 00% continuous duty Inlet orifice,0 mm (low power), mm (high power) Electrical connection Industrial Standard, mm (corresponding to choosen coil) Solenoid coil mounting Four positions x 90 Manual override Push and turn to lock (plastic) Protection class IP (with sealed plug) Ambient/Media temperature: Solenoid pilot actuated valves C ( F) Air pilot actuated valves C ( F) Air supply must be dry enough to avoid ice formation at temperatures below + C (+ F). Materials: M/7..., M/7... Body and sub-base: Die-cast zinc alloy Spool: Aluminium Centering mechanism: Steel or plastic Seals: NBR M/78 Body and sub-base: Die-cast Aluminium Bush: Brass Spool: and end caps: Light alloy Cushion discs: PU Seals: NBR without notice, the specifications given in this document. (990-70b) 0 Norgren Ltd. / en..0.0
2 M/700; / & / / Solenoid pilot actuated valves Symbol *) Power see table on page Port size Actuation Pilot supply Flow (l/min) Operating pressure (bar) Power *) Voltage Weight (kg) Drawing No. Model G/8 Solenoid/air spring Internal Low V d.c 0,9 M/7//MAJ G/8 Solenoid/air spring Internal Low 0 V a.c. 0,9 M/7//MA8J G/8 Solenoid/air spring Internal Low 0 V a.c. 0,9 M/7//MA9J G/8 Solenoid/air spring Internal Low Without coil QM/7//MA/ G/8 Solenoid/air spring Internal High V d.c 0,9 M/7//MD8J G/8 Solenoid/air spring Internal High 0 V a.c. 0,9 M/7//MD88J G/8 Solenoid/air spring Internal High 0 V a.c. 0,9 M/7//MD89J G/8 Solenoid/air spring Internal High Wi hout coil QM/7//MD/ G/ Solenoid/air spring Internal 90, Low V d.c,07 M/7//MAJ G/ Solenoid/air spring Internal 90, Low 0 V a.c.,07 M/7//MA8J G/ Solenoid/air spring Internal 90, Low 0 V a.c.,07 M/7//MA9J G/ Solenoid/air spring Internal 90, Low Wi hout coil QM/7//MA/ G/ Solenoid/air spring Internal 90, High V d.c,07 M/7//MD8J G/ Solenoid/air spring Internal 90, High 0 V a.c.,07 M/7//MD88J G/ Solenoid/air spring Internal 90, High 0 V a.c.,07 M/7//MD89J G/ Solenoid/air spring Internal 90, High Wi hout coil QM/7//MD/ G/ Solenoid/air spring Internal 00, Low V d.c., M/7//MAJ G/ Solenoid/air spring Internal 00, Low 0 V a.c., M/7//MA8J G/ Solenoid/air spring Internal 00, Low 0 V a.c., M/7//MA9J G/ Solenoid/air spring Internal 00, Low Wi hout coil QM/7//MA/ G/ Solenoid/air spring Internal 00, High V d.c, M/7//MD8J G/ Solenoid/air spring Internal 00, High 0 V a.c., M/7//MD88J G/ Solenoid/air spring Internal 00, High 0 V a.c., M/7//MD89J G/ Solenoid/air spring Internal 00, High Wi hout coil QM/7//MD/ G Solenoid/air and spring Internal 980, High V d.c, 7 M/78/7/MD8J G Solenoid/air and spring Internal 980, High 0 V a.c., 7 M/78/7/MD88J G Solenoid/air and spring Internal 980, High 0 V a.c., 7 M/78/7/MD89J G/8 Solenoid/solenoid Internal Low V d.c. 0,7 M/7//MAJ G/8 Solenoid/solenoid Internal Low 0 V a.c. 0,7 M/7//MA8J G/8 Solenoid/solenoid Internal Low 0 V a.c. 0,7 M/7//MA9J G/8 Solenoid/solenoid Internal Low Without coil QM/7//MA/ G/8 Solenoid/solenoid Internal High V d.c 0,7 M/7//MD8J G/8 Solenoid/solenoid Internal High 0 V a.c. 0,7 M/7//MD88J G/8 Solenoid/solenoid Internal High 0 V a.c. 0,7 M/7//MD89J G/8 Solenoid/solenoid Internal High Wi hout coil QM/7//MD/ G/ Solenoid/solenoid Internal Low V d.c.,8 M/7//MAJ G/ Solenoid/solenoid Internal Low 0 V a.c.,8 M/7//MA8J G/ Solenoid/solenoid Internal Low 0 V a.c.,8 M/7//MA9J G/ Solenoid/solenoid Internal Low Wi hout coil QM/7//MA/ G/ Solenoid/solenoid Internal High V d.c,8 M/7//MD8J G/ Solenoid/solenoid Internal High 0 V a.c.,8 M/7//MD88J G/ Solenoid/solenoid Internal High 0 V a.c.,8 M/7//MD89J G/ Solenoid/solenoid Internal High Wi hout coil QM/7//MD/ G/ Solenoid/solenoid Internal Low V d.c., M/7//MAJ G/ Solenoid/solenoid Internal Low 0 V a.c., M/7//MA8J G/ Solenoid/solenoid Internal Low 0 V a.c., M/7//MA9J G/ Solenoid/solenoid Internal Low Wi hout coil QM/7//MA/ G/ Solenoid/solenoid Internal High V d.c, M/7//MD8J G/ Solenoid/solenoid Internal High 0 V a.c., M/7//MD88J G/ Solenoid/solenoid Internal High 0 V a.c., M/7//MD89J G/ Solenoid/solenoid Internal High Wi hout coil QM/7//MD/ G Solenoid/solenoid Internal High V d.c,0 8 M/78//MD8J G Solenoid/solenoid Internal High 0 V a.c.,0 8 M/78//MD88J G Solenoid/solenoid Internal High 0 V a.c.,0 8 M/78//MD89J en..0.0 without notice, the specifications given in this document. (990-70b) 0 Norgren Ltd. /
3 M/700; / & / / Solenoid pilot actuated valves Symbol *) Power see table below Port size Actuation Function Pilot supply Flow Operating pressure Power *) Voltage Weight Drawing Model (l/min) (bar) (kg) No. G/ Solenoid/solenoid APB Internal 90, Low V d.c, M/7//MAJ G/ Solenoid/solenoid APB Internal 90, Low 0 V a.c., M/7//MA8J G/ Solenoid/solenoid APB Internal 90, Low 0 V a.c., M/7//MA9J G/ Solenoid/solenoid APB Internal 90, Low Wi hout coil QM/7//MA/ G/ Solenoid/solenoid APB Internal 90, High V d.c, M/7//MD8J G/ Solenoid/solenoid APB Internal 90, High 0 V a.c., M/7//MD88J G/ Solenoid/solenoid APB Internal 90, High 0 V a.c., M/7//MD89J G/ Solenoid/solenoid APB Internal 90, High Without coil QM/7//MD/ G/ Solenoid/solenoid APB Internal 00, Low V d.c, M/7//MAJ G/ Solenoid/solenoid APB Internal 00, Low 0 V a.c., M/7//MA8J G/ Solenoid/solenoid APB Internal 00, Low 0 V a.c., M/7//MA9J G/ Solenoid/solenoid APB Internal 00, Low Without coil QM/7//MA/ G/ Solenoid/solenoid APB Internal 00, High V d.c, M/7//MD8J G/ Solenoid/solenoid APB Internal 00, High 0 V a.c., M/7//MD88J G/ Solenoid/solenoid APB Internal 00, High 0 V a.c., M/7//MD89J G/ Solenoid/solenoid APB Internal 00, High Without coil QM/7//MD/ G/ Solenoid/solenoid COE Internal Low V d.c, M/77//MAJ G/ Solenoid/solenoid COE Internal Low 0 V a.c., M/77//MA8J G/ Solenoid/solenoid COE Internal Low 0 V a.c., M/77//MA9J G/ Solenoid/solenoid COE Internal Low Wi hout coil, QM/77//MA G/ Solenoid/solenoid COE Internal High V d.c, M/77//MD8J G/ Solenoid/solenoid COE Internal High 0 V a.c., M/77//MD88J G/ Solenoid/solenoid COE Internal High 0 V a.c., M/77//MD89J G/ Solenoid/solenoid COE Internal High Without coil, QM/77//MD G/ Solenoid/solenoid COE Internal 00, Low V d.c, M/77//MAJ G/ Solenoid/solenoid COE Internal 00, Low 0 V a.c., M/77//MA8J G/ Solenoid/solenoid COE Internal 00, Low 0 V a.c., M/77//MA9J G/ Solenoid/solenoid COE Internal 00, Low Without coil QM/77//MA G/ Solenoid/solenoid COE Internal 00, High V d.c, M/77//MD8J G/ Solenoid/solenoid COE Internal 00, High 0 V a.c., M/77//MD88J G/ Solenoid/solenoid COE Internal 00, High 0 V a.c., M/77//MD89J G/ Solenoid/solenoid COE Internal 00, High Without coill QM/77//MD Spare coils and alternative voltages mm coil -,0 mm orifice (low power) for connector interface acc. to industrial standard Voltage Power Inrush/Hold Model V d.c W QM/8/J/ V d.c W QM/8/J/ V a.c. /, VA QM/8/J/ 0/0 V 0/0 Hz /, VA QM/8/8J/ 0/0 V 0/0 Hz / VA QM/8/9J/ mm coil -, mm orifice (high power) for connector interface acc. to industrial standard Voltage Power Inrush/Hold Model V d.c 7, W QM/8/8J/ V d.c W QM/8/8J/ V a.c. /8 VA QM/8/8J/ 0/0 V 0/0 Hz /8 VA QM/8/88J/ 0/0 V 0/0 Hz /8 VA QM/8/89J/ Connector plugs - ordered separately Industrial standard mm -pole + PE 0788 / without notice, the specifications given in this document. (990-70b) 0 Norgren Ltd. en..0.0
4 M/700; / & / / air pilot actuated valves Symbol Port size Actuation Flow (l/min) Operating pressure (bar) Pilot pressure (bar) Weight (kg) Drawing No. G/8 Air/air ,7 + (0, x supply pressure) 0, 9 M/70/ G/ Air/air ,7 + (0,7 x supply pressure) 0,9 M/70/ G/ Air/air , + (0,7 x supply pressure),0 M/70/ G/8 Air/air (0, x supply pressure) 0, 0 M/70/ G/ Air/air , + (0, x supply pressure) 0,8 M/70/ G/ Air/air (0, x supply pressure), M/70/ G Air/air ,7 + (0, x supply pressure),00 M/78/ G/8 Priority air/air *) 0, 0 M/70/ G/ Priority air/air *) 0,99 M/70/ G/ Priority air/air *),0 M/70/ G/ Air/spring , + (0,0 x supply pressure) *),00 M/70/0 G/ Air/spring , + (0, x supply pressure) *), M/70/0 G Air/air spring (0, x supply pressure),00 M/78/ Model 8 G/ Air/single impulse , x supply pressure ( bar) *) 0,90 7 M/787 *) *) Large end 0,8 + (0,0 x supply pressure) bar, at zero; Small end,0 + (0, x supply pressure) bar, at zero If air is permanently applied to the pilot pressure to is 0,7 + (0, x supply pressure) bar when = supply *) Large end 0,8 + (0,08 x supply pressure) bar, at zero; Small end, + (0, x supply pressure) bar, at zero If air is permanently applied to the pilot pressure to is 0,7 + (0,7 x supply pressure) bar when = supply *) Large end 0, + (0,08 x supply pressure) bar, at zero; Small end,0 + (0, x supply pressure) bar, at zero If air is permanently applied to the pilot pressure to is 0, + (0,7 x supply pressure) bar when = supply *) M/70/0 and M/70/0 when used with dual supplies (i.e. main supply to both ports and ) the supply pressure range is... 7 bar. This valve is not intended to be held in the operated condition for more than hours. Where the operation involves delay in excess of hours, please consult our Technical Service. *) Single pulse valve; signal time: 00 ms; pilot signal sequence: 00 ms. Application of a signal on reset port 8 ensures that the valve is in the» flow condition / air pilot actuated valves Symbol Port size Actuation Function Flow (l/min) Operating pressure (bar) Pilot pressure (bar) Weight (kg) Drawing No. G/ Air/air APB , + (0, x supply pressure) 0,8 M/70/ G/ Air/air APB , + (0, x supply pressure),8 M/70/ G/ Air/air COE , + (0, x supply pressure) 0,8 M/7/ G/ Air/air COE , + (0, x supply pressure),8 M/7/ Model Seal kit Valve series Port size Seal kit M/70/...; M/7/... G/8 QM/70/00 M/70/...; M/7/...; M/77/... G/ QM/70/00 M/787 G/ QM/787/00 M/70/...; M/7/...; M/77/... G/ QM/70/00 M/78/...; M/78/... G QM/78/00 en..0.0 without notice, the specifications given in this document. (990-70b) 0 Norgren Ltd. /
5 M/700; / & / Drawings, 7, , 8 G/8 9 8, 9, 8 G/8 8, 9 7, 7, 7, 7, 8 8 7, 7 7, 7 7, 7, 9, 9, 0 G/ 9, 8 9, 8 G/ Clockwise 90 turnable Mounting threads M through sub-base (M/7, M7) Screwdriver manual override Exhaust port (M) with diffuser Minimum / without notice, the specifications given in this document. (990-70b) 0 Norgren Ltd. en..0.0
6 M/700; / & / 0, 0,,,,, 0 9 G/ 89,, 9, 8 9 G/ 89, 9, 8, 7,,, 7, 8,,, 7, 8, 97, 8 Clockwise 90 turnable Mounting threads M8 through sub-base (M/7) Screwdriver manual override Exhaust port (M) with diffuser Minimum en..0.0 without notice, the specifications given in this document. (990-70b) 0 Norgren Ltd. /
7 M/700; / & / 7 0, > G G 0 99, 9 0 Clockwise 90 turnable Mounting threads M0, 0 mm deep (M/78) Screwdriver manual override Exhaust port (M) with diffuser Minimum / without notice, the specifications given in this document. (990-70b) 0 Norgren Ltd. en..0.07
8 M/700; / & / 8 0, > G G 0 99, 9 0 Clockwise 90 turnable Mounting threads M0 through sub-base (M/78) Screwdriver manual override Exhaust port (M) with diffuser Minimum en without notice, the specifications given in this document. (990-70b) 0 Norgren Ltd. /
9 M/700; / & / 9, 7 0, 7 G/8, 7 G/8, 7 8, 9 G/8 8, 9 G/8 9, 9, 7, 7, 7, 7, 8 8 7, 7 7, 7 7, 7, G/8 7, 9, G/8 7, 9, G/ G/ 9, 9, , 0, G/8,, 9, G/8,, 9, 9 G/ 9 G/ 89, 89, 7,,, 7, 8, 97,,, 7, 8, 8 Mounting threads M through sub-base (M/70, M70) M8 through sub-base (M/70) Minimum / without notice, the specifications given in this document. (990-70b) 0 Norgren Ltd. en..0.09
10 M/700; / & / 0, G/8,, 9 G/ 9, 89, 7,,, 7, 8, 97, 0, > G 9 9 G 0 99, 9 0 Mounting threads M8 through sub-base (M/70) M0 through sub-base (M/78) Minimum en..0.0 without notice, the specifications given in this document. (990-70b) 0 Norgren Ltd. /
11 M/700; / & / 7 7, 7 7, G/8 9, 7, 8 G/8 8 9, 0 8 G/ Mounting threads M through sub-base (M/787) Minimum Signal reset port Warning These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under»technical features/data«. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems or other applications not within published specifications, consult IMI NORGREN. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. / without notice, the specifications given in this document. (990-70b) 0 Norgren Ltd. en..0.
97105 Namur direct pneumatically actuated 3/2 and 5/2 spool valves
direct pneumatically actuated / and / spool valves flanged with NAMUR Interface For single and double operated actuators Valves for safety systems up to SIL (IEC 108) Crossover-free switching, switch-over
More informationNuGGeT 200 spool VALVes
NuGGeT 00 spool /, /8, or / Ports, specially coated glandless spool and sleeve for extreamly long life Available with integral flow regulators on Iso # and # sizes Low power solenoids and manual override
More informationVAL-110. Nugget 200 Spool Valves 1/4" and 3/8" Solenoid Pilot Actuated 3/2, 5/2, & 5/3 Inline Valves. Valves. Solenoid Operating Specifications
Nugget 200 Spool 1/4" and 3/8" Solenoid Pilot Actuated 3/2, 5/2, & 5/3 Inline Long lasting spool design High flow compact valves Four mounting styles available Wide range of operators and voltages available
More informationMonitored Pneumatic Valves On Series Ported Manifold
Monitored Pneumatic Valves On Series Ported Manifold Patented Technology SUITABLE FOR RISK CATEGORY 4 APPLICATIONS As per EN 954-1 & AS4024.1 SIL 3 as per IEC 61508 Applications Include: Pneumatic Presses
More information½ Monitored Pneumatic Valves On Series Ported Manifold
½ Monitored Pneumatic Valves On Series Ported Manifold Patented Technology SUITABLE FOR RISK CATEGORY 4 APPLICATIONS As per AS4024.1-Part 1502 & 1502 SIL 3 as per IEC 61508 & EN ISO 13849-1 Applications
More information½ Monitored Pneumatic Valve Patented Technology
½ Monitored Pneumatic Valve Patented Technology PBM4-S (Valve only air service equipment not included) SUITABLE FOR RISK CATEGORY 4 APPLICATIONS As per AS4024.1-Part 1502 & 1502 SIL 3 as per IEC 61508
More informationAir. Pressure. Motion. nnnnnnnn
Air. Pressure. Motion. nnnnnnnn AIRTEC classic ejectors Page 10.001 AIRTEC column ejectors Vacuum generators with 1, 4, 6 and 8 independent vacuum circuits. Series HV and HF Page 10.010 MI and MIF Page
More informationCondensate drains WA/PWEA
Condensate drains WA/PWEA Condensate drains WA Function -Q- Temperature range 0 +60 C -L- Operating pressure 1.5 16 bar -H- Note In order to close, the automatic condensate drain WA-2 requires a flow rate
More informationVacuum generators VADM/VADMI
Key features Product overview Vacuum generators All Festo vacuum generators have a single-stage design and operate according to the Venturi principle. The product series described below have been designed
More informationVacuum unit ideal for controlling large flow rates Vacuum unit VSQ/VSQP series
Vacuum unit ideal for controlling large flow rates Vacuum unit VSQ/VSQP series Features This 1.5 mm width vacuum unit is ideal for controlling large flow rates. A vacuum ejector unit and vacuum switching
More informationHow to Order. Combination of supply valve. Light/Surge voltage suppressor. Electrical entry. and release valve Pilot valve. Voltage 5 L Z E C.
Vacuum Module: Vacuum Pump System Series ZX How to Order Valve unit N.C. type Components unit ZX100 K1 Combination of supply valve and release valve Pilot valve Voltage Electrical entry Light/Surge voltage
More informationVacuum generators VADM/VADMI
Vacuum generators VADM/VADMI Vacuum generators Key features Product overview Vacuum generator All Festo vacuum generators have a single-stage design and operate according to the venturi principle. The
More informationHigh Pressure Water - Descale Valves - VXXX Series. Quad-S TM Poppet Cartridge Zero Leakage, Media Piloted Raw Water Operation
Bulletin B0201 - Date 03/05 High Pressure Water - Descale Valves - VXXX Series Quad-S TM Poppet Cartridge Zero Leakage, Media Piloted Raw Water Operation Proudly Made in USA Water Hydraulics Inc. Visit
More informationmulti-stage vacuum generators - general information
multi-stage vacuum generators - general information Our multi-stage vacuum generators produce a maximum vacuum of 90%, equal to a final vacuum level of 100 mbar abs., with different suction capacities.
More information! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-214(C) Series 61 Low Water Cut-Off OPERATION
Series 61 Low Water Cut-Off Typical Applications: - Primary or secondary low water cut-off for hot water and steam boilers. - Low water cut-off - High water cut-off - Alarm actuator OPERATION Maximum Boiler
More informationVacuum generators. Festo core product range Covers 80% of your automation tasks
Vacuum generators q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement and storing complexity
More informationINDEX APPLIANCE GAS WATER HEATER CONTROLS 150 ELECTRIC WATER HEATER THERMOSTATS 151 SNAP DISC CONTROLS/LIMITS/SWITCHES 152 GAS DRYER VALVES 153
INDEX GAS WATER HEATER CONTROLS 150 ELECTRIC WATER HEATER THERMOSTATS 151 SNAP DISC CONTROLS/LIMITS/SWITCHES 152 Model(s) Page(s) Flush Mount Fan/Limit/Attic Fan Control... 152 GAS DRYER VALVES 153 Model(s)
More informationCondensate Drain Valves
Innovative Compressed Air Products A Complete Line Of Drain Valves To Fit Every Compressed Air Condensate Removal Application WDV Series Condensate Drain Valves Leading Edge Technology CORPORATION Dimensions
More informationMMEngineering. Suction lifter. Lightning fast suction for lifting and moving. with only on vaccum line. Suction lifters Vacuum-operated
6 available sizes Integral suction lifter Accessories Lightning fast suction for lifting and moving with only on vaccum line s Vacuum-operated Integral suction lifter Compressed-air Page 3-01.. Page 3-02..
More informationAdsorption dryer SDAT
Solutions to your fluid power problems Adsorption dryer SDAT Operating instructions Issue 04/2004 DRUMAG GmbH Fluidtechnik Glarnerstrasse 2 D-79713 Bad Säckingen Telefon: +49 (0)7761 / 5505-0 Fax: +49
More informationMODEL A-316 CARBON MONOXIDE (CO) MONITOR AND ALARM FOR COMPRESSED AIR TESTING
MODEL A-316 CARBON MONOXIDE (CO) MONITOR AND ALARM FOR COMPRESSED AIR TESTING FOR OPERATION FROM 115 AC POWER Andersen Medical Gas 12 Place Lafitte Madisonville, LA 70447 http://www.themedicalgas.com 1-866-288-3783
More informationSpecification/ Data Sheet
Specification/ Data Sheet TRITON RP Agent Release Control Panel FEATURES Agent Release Control Panel designed specifically for suppression release operation with: Four initiating device circuits (IDCs)
More informationFlopurge TS. Operation Manual
Flopurge TS Operation Manual Part Number 079-0204 Spectron Gas Control Systems United Kingdom Unit 4, Herald Court, University of Warwick Science Park, Coventry, CV4 7EZ +44 (0)24 7641 6234 sales@spectron-gcs.com
More informationTechnical Specification VFD
Technical Specification - 3-6 VFD Pilot valve enclosures suitable for use in hazardous certified environments. These enclosures are designed and tested to contain both flame and the ignition of dust and
More informationFlostop TS D7E and A8E. Operation Manual
Flostop TS D7E and A8E Operation Manual United Kingdom Spectron Gas Control Systems Ltd, Unit 4, ATU1, University of Warwick science Park, Coventry, +44 (0) 24 7641 6234 sales@spectron-gcs.com Germany
More informationOPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"
OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER Electric Heater Company Base Model "BWXP" HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE: (203)
More informationCompressed air treatment. Condensate drains OMEGA AIR
Compressed air treatment 77 Condensate drains OMEGA AIR 78 Condensate drains EMD SERIES ELECTRONIC CONDENSATE DRAIN drain capacity inlet connection 16 bar 12 l/h 1/2 1,5 to 65 C air compressor (piston
More informationCentro-Matic Automated Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the
More informationAdsorption dryers PDAD
Key features Description Areas of application Features/Advantages/Benefits Cold-regenerating adsorption dryer with defined pressure dew point and high flow rate for decentralised compressed air drying
More informationMin Series. Modular Venturi Vacuum Pumps Min Series. Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off
Modular Venturi Vacuum Pumps Min Series Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off In keeping pace with industry s need for improved automation and material handling methods,
More informationPWM expansion valves 2028
PWM expansion valves 2028 Application Solenoid expansion valve Castel type 2028 regulates the refrigerant flow into the evaporator by modulating the opening time phase of the plug and so permitting a wide
More informationVacuum suction nozzle OVEM-...-1P/1N
Vacuum suction nozzle OVEM-...-1P/1N Operating instructions (Translation of the original instructions) Festo AG & Co. KG Ruiter Straße 82 73734 Esslingen Germany +49 711 347-0 www.festo.com 8085608 2018-01b
More informationVacuum Module: Ejector System/Vacuum Pump System. For electronic components and precision components up to 100 g
1 Vacuum Module: Ejector System/Vacuum Pump System For electronic components and precision components up to 100 g Modular design Customized application function through selection of module components.
More informationProduct Data Sheet Adsorption Dryer DPS (A)
Version: 1.0.5 Author: Tassilo Tappe Date:13.07.2012 Field of application Adsorption dryers of the DPS series are designed for drying compressed air and nitrogen to pressure dew points of -25 C to -70
More informationMVG. Modular Vacuum Grippers. US5
Modular Vacuum Grippers MVG www.coval.com US5 MVG COVAL s MVG Series: Customized Customized Solution COVAL s MVG series vacuum grippers correspond perfectly to the expectations of integrators and users:
More informationProductinformatie BAFA.NL BAFA.NL A.U.K. MÜLLER GMBH & CO. KG
Productinformatie A.U.K. MÜLLER GMBH & CO. KG Product Series 1.010.6 A. u. K. Müller Solenoid valves Control valves Special valves and systems A. u. K. Müller GmbH & Co. KG Dresdener Str. 162 D-40595 Düsseldorf/Germany
More informationF PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.
F-2000 PC and AO OUTPUT BOARDS INSTRUCTION MANUAL Blue-White R Industries, Ltd. 500 Business Drive Huntington Beach, CA 92649 USA Phone: 714-89-8529 FAX: 714-894-9492 E mail: sales@blue-white.com or techsupport@blue-white.com
More informationComplex Vacuum Generator realizing Stable and High-Speed Response Vacuum Generator VN Series
EXTERNAL GENERATOR CONTROLLER PAD ACCESSORIES Complex Vacuum Generator realizing Stable and High-Speed Response Vacuum Generator Series 282 Suitable for semiconductor industry such as IC chip loader or
More informationINSTRUCTION MANUAL MM-615E. Series FS1 High Sensitivity Liquid Flow Switch
INSTRUCTION MANUAL MM-615E 246717 Series FS1 High Sensitivity Liquid Flow Switch SPECIFICATIONS Maximum Liquid Pressure: 100 psi 7 kg/cm 2 ) Liquid Temperature Range TL): 32-225 F 0-107 C) Ambient Temperature
More information21 20 LITER GAS FRYER FFA3200 INSTALLATION AND SERVICING.
21 20 LITER GAS FRYER FFA3200 INSTALLATION AND SERVICING www.anvilworld.com 20 ALL ANVIL EQUIPMENT COMES WITH A ONE YEAR WARRANTY ON COMPONENTS AND DEFECTIVE WORKMANSHIP. www.anvilworld.com 19 20 LITER
More informationAir Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)
http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Filter for Removing Dust and Drain in Compressed Air Air Filter 220 Filter for Drain and Dust (Filtering Accuracy: 5µm) Resin-made
More information3500 SERIES CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL
3500 SERIES CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL EFFECTIVE JULY 30, 2014 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items specified
More informationThermostats type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Thermostats type KPU REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction... 3 Features... 3 Approvals... 3 Technical data... 3 Regulating ranges... 4 Ordering... 4 Contact systems...
More informationSECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM
PART 1 GENERAL 1.01 SUMMARY SECTION 15371 KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM A. Section Includes: A complete wet chemical automatic fire suppression system for the exhaust hood, including necessary
More informationContact Davies Pros On Controls For Proper Application. Solenoid Valves
E45 Davies Stocks A Full Line Of & Coils Including Brands Like Asco & Parker E46 Two Way - Brass - Pilot Operated - 8210 Series General Purpose (Normally Closed) Wide range of pressure ratings, sizes,
More informationF261 Series Fluid Flow Switches
F261 Series Fluid Flow Switches Product Bulletin Code No. LIT-12011987 Issued July 22, 2015 Refer to the QuickLIT website for the most up-to-date version of this document. The F261 Series Flow Switches
More informationPART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS
PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. General: 1. To obtain maintenance and repair standards for boiler burners (Section 15555A) and boiler tubes (Section 15555B), contact the DPS Project
More informationKITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM
PART 1 GENERAL 1.01 SUMMARY SECTION 15371 KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM A. Section Includes: A complete automatic fire suppression system for the exhaust hood, including necessary accessories.
More informationTwo-Position Electric Duplex Room Thermostats
TC-XX Series, TC-XX Series, TF- Series Two-Position Electric Duplex Room Thermostats These thermostats provide on-off control of heating/cooling systems. TC-XX Series, TC-XX Series, TF- Series Features:
More informationFCHM Hydromatic Pump Control Module
FCHM Hydromatic Pump Control Module Use To maintain and control water pressure, within a pumped system, for the supply to industrial processes and heating systems. Ensures constant flow and pressure to
More informationSIHI Dry GD S Sizes S450, S650
SIHI Dry GD S Sizes S450, S650 Single Stage Vacuum System - General Design Dry Running Screw Vacuum Pump Experience In Motion Pressure range: Pumping Speed: < 0.001 to 1013 mbar 0.00075 to 760 torr 450
More informationWater separators MS-LWS, MS series
Water separators MS-LWS, MS series Water separators MS-LWS, MS series Product range overview MS series service units Type Size Pressure regulation range [bar] Grade of filtration [μm] Pneumatic connection
More informationAutomatic Drain Valves. Lasting Values. Series LDV
Lasting Values Automatic Drain Valves Series LDV Zero Air Loss Noise Free Condensate Sensing Type Design Patented India s Largest Exporter of Compressed Air Treatment Products The LDV Series Trident s
More informationAPPLICATIONS. For the accelerated circulation of hot water in heating circuits with duty point optimisation
OPERATING RANGE Flow rate of up to m /h Manometric head of up to m Max. operating pressure bar Min. intake pressure, bar at 9 C Water temperature range + at + C * EEI-Part, * for a ambient temperature
More informationVacuum generators VAD/VAK
Vacuum generators Key features Product overview Vacuum generator All Festo vacuum generators have a single-stage design and operate according to the venturi principle. The product families described below
More informationIA Inlet Actuator. Instruction Manual. IA Inlet Actuator Models: IA0090 IA0090P. Munters Corporation, March 2017 QM1235r1
Instruction Manual IA Inlet Actuator IA Inlet Actuator Models: IA0090 IA0090P Munters Corporation, March 2017 QM1235r1 1 IA Inlet Actuator Manual for use and Maintenance Thank You: Thank you for purchasing
More informationInstallation Instructions for P/N: Algas-SDI thermostat retrofit kit
151 South Michigan Street, Seattle, WA 98108 U.S.A. Phone: 206-789-5410 Fax: 206-789-5414 Internet: www.algas-sdi.com Installation Instructions for P/N: 41073 Algas-SDI thermostat retrofit kit Field Kit
More informationOperation Manual. Time controlled condensate drain unit UFZ. 000_H_uf_UFZ_GB_R00_D011002
Time controlled condensate drain unit UFZ 000_H_uf_UFZ_GB_R00_D011002 ultramatic UFZ Angular plug Time control unit Valve Control panel Pressure side connection Screw-type conduit fitting with strain relief
More informationSECTION AUTOMATIC TRANSFER SWITCHES
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 36 23 SPEC WRITER NOTE: Use this section only for NCA projects. Delete between //--// if not applicable to project. Also, delete any other item or paragraph
More informationTHERMOSTATS THERMOSTATS HEATING AND COOLING
THERMOSTATS HEATING AND COOLING LASCO CONTROLS Deluxe Horizontal Thermostats 36-0214 25 Millivolt Heat only 36-0215 1 36-0216 25 24 Volt Heat only 36-0217 1 36-0218 25 24 Volt Heat/Cool 36-0219 1 Note:
More informationTIMER CONTROLLED DRAINS
TIMER CONTROLLED LED DRAINS OPTIMUM COMBO D-LUX EAD TEC-11 TEC-44 HIGH-PRESSURE DRAIN FLEXIBILITY REL LIABLE COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS Condensate drains INDEX Chapter
More informationIS Series Pressure Sensing Switches
IS Series Pressure Sensing Switches FEATURES INSTALLATION INSTRUCTIONS IS3 PRESSURE SWITCH APPLICATION IS2 PRESSURE SWITCH The IS Series of pressure sensing switches offers the same proven compression
More informationVacuum generation Content
Vacuum generation Content Inline ejectors... 513 Base and Heavy-duty ejectors... 526 Multi-chamber ejectors... 546 Compact ejectors... 555 Feed ejectors... 569 Silencers for vacuum ejectors... 577 Rotary
More informationDIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)
DIESEL ENGINE CONTROL UNIT DCU 205 - USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) 64 84 52 00 Fax: (+47) 64 84 52 12 office@auto-maskin.no - 1 - TABLE OF CONTENTS 1. INTRODUCTION TO THE DCU 205...4
More informationPRIUX HOME D. High-efficiency double circulating pumps Heating Air conditioning 50 Hz OPERATING RANGE APPLICATIONS BENEFITS
OPERATING RANGE Flow rate of up to 7 m /h* Manometric head of up to 8 mwc Max. operating pressure bar Min. suction pressure, bar at 9C Temperature range -C at 9C Max. ambient temperature +C EEI-Part Priux
More informationINSTALLING AND USING THE KELCO F50 PUMP CONTROLLER
INSTALLING AND USING THE KELCO F50 PUMP CONTROLLER Please read this installation sheet fully and carefully. The F50 Pump Controller is a mains voltage device. Death or serious injury may result if this
More informationProduct Specification RobExtractSpray 2400/4400
Product Specification RobExtractSpray 2400/4400 3HXC 7111-1 December 1999 ABB Flexible Automation The information in this document can be subject to change without prior notice and should not be regarded
More informationSafety Light Curtains Area Access Control
Presence Sensing Safety Devices Description The AAC photoelectric safety switch is a single-beam, noncontact presence sensing safety device consisting of separate transmitter and receiver units. The light
More information! WARNING. Before using product, read and understand instructions.
McDonnell & Miller Installation & Maintenance Instructions MM-607(B) Series FS7-4 Industrial Liquid Flow Switch (specified models only) Series FS7-4 OPERATION This control is an independently mounted water
More informationDC200 Digital Dispenser Operating Manual
DC200 Digital Dispenser Operating Manual 2015 Fisnar Phone: (973) 646-5044 E-mail: info@fisnar.com Table of Contents Product Safety Statements 4 Specifications 6 Accessories 6 External Controls 7 Machine
More informationEffective october 14, 2014
COS-20G combi oven-steamer REPLACEMENT PARTS LIST Effective october 14, 2014 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items specified
More informationTIMER CONTROLLED DRAINS
TIMER CONTROLLED LED DRAINS FLUIDRAIN EZ-1 TEC-11 TEC-44 QUICK-SET D-LUX HIGH PRESSURE ENVIRONMENT DRAIN FLEXIBILITY SAFEGUARD REL LIABLE COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS
More informationUV Flame Supervision System
7 783 UV Flame Supervision System DETACTOGYR LFE50 Series 02 ISO 9001 The LFE50 is a self-checking UV flame supervision system designed for use with continuously operating burners or for burners running
More informationDual Pressure Controls
PRESSURE CONTROLS Dual Pressure Reset Hp/Lp Range Differential kpa kpa Ranco Dual Pressure G0048 017-8711* -30 to 700 700 to 3000 62 to 393 350 bar fixed G0056 017-8701 -30 to 700 700 to 3000 62 to 393
More informationSuction cups VAS/VASB
Suction cups VAS/VASB q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement and storing complexity
More informationWILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS
INSTRUCTION MANUAL FOR WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS DE3 - DE5 OPERATIONS GENERAL This instruction manual covers the installation, operation, maintenance and troubleshooting
More informationLINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems
LINETRAXX RCMA420 Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems RCMA420_D00059_01_D_XXEN/06.2016 LINETRAXX RCMA420 Residual current monitor for monitoring AC,
More informationSECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS
PART 1 GENERAL 1.01 SECTION INCLUDES A. Pipe and Pipe Fittings. B. Air compressor. C. Air receiver and accessories. D. Aftercooler. E. Refrigerated air dryer. F. Pressure reducing station. 1.02 RELATED
More informationVAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1
Model TRO24T4XYZ1 Description The TRO24T4XYZ1 is a combination controller and thermostat. The VAV Thermostat Controller is designed for simple and accurate control of any variable air volume box in a number
More informationINSTRUCTION MANUAL MM-601REVI. Series FS4-3 General Purpose Liquid Flow Switch
INSTRUCTION MANUAL MM-601REVI 246796 Series FS4-3 General Purpose Liquid Flow Switch SPECIFICATIONS Maximum Liquid Pressure: 160 psi (11.3 kg/cm 2 ) Liquid Temperature Range (TL): 32-300 F (0-149 C) Ambient
More information! WARNING. Before using product, read and understand instructions.
Installation & Maintenance Instructions MM-616 Series FS-5 General Purpose Liquid Flow Switch specified models only) Series FS-5 OPERATION This control is an independently mounted water flow sensing device
More informationM7100 Pressure Transducer
SPECIFICATIONS Performance standard on and off highway engine and vehicle OEMs Rugged for heavy equipment and outdoor use Designed specifically for high volume applications Stainless steel wetted surfaces
More informationSECTION HEATING BOILER FEEDWATER EQUIPMENT
SECTION 23 53 00 HEATING BOILER FEEDWATER EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes boiler feedwater pumps, de-aerators, accessories, controls and tanks. 1.2 REFERENCES A. ASME (American
More informationOxygen Sensing Solutions
Oxy020608 Issue H Oxygen Sensor Catalogue SST SENSING LTD Oxygen Sensing Solutions 1 Oxygen Sensing SST Sensing are experts in the field of oxygen and fluid measurement. We have a comprehensive range of
More informationCaresaver Universal Refrigerant Recovery Unit
Operation Manual Caresaver Universal Refrigerant Recovery Unit 2 CONTENTS CHAPTER 1 INTRODUCTION AND OVERVIEW Specifications 3 Health and Safety 4-5 Component Location and Identification 6-9 CHAPTER 2
More informationQUALITY ASSURANCE/QUALITY CONTROL DOCUMENTATION SERIES OPTEC NGN-2 NEPHELOMETER AUDIT PROCEDURES (IMPROVE PROTOCOL) STANDARD OPERATING PROCEDURE
QUALITY ASSURANCE/QUALITY CONTROL DOCUMENTATION SERIES TITLE OPTEC NGN-2 NEPHELOMETER AUDIT PROCEDURES (IMPROVE PROTOCOL) TYPE STANDARD OPERATING PROCEDURE NUMBER 4700 DATE JANUARY 1995 AUTHORIZATIONS
More informationRA15/6T & TB Conversion Valve
Applications: continue on. This provides continuous flow, but inherent to series piping the supply water temperature will decrease as it flows through the system and when it mixes with return water from
More informationPower Flame Incorporated
Power Flame Incorporated SUGGESTED SPECIFICATION FOR MODEL NVC ULTRA LOW NOx GAS BURNERS SUB 9 PPM NOx THE POWER TO MANAGE ENERGY 2001 South 21st Street, Parsons, Kansas 67357 Telephone: 620-421-0480,
More informationAir Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)
http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Filter for Removing Dust and Drain in Compressed Air Air Filter 220 Filter for Drain and Dust (Filtering Accuracy: 5µm) Resin-made
More informationInstallation Instructions for W2H Series Signals
Installation Instructions for W2H Series Signals IF1513 A Description and Operation DIMENSIONS W2H A 8 7/8" (225 mm) B 8 1/4" (210 mm) C 13" (330 mm) Figure 1. Speaker/Amplifier Dimensions The W2H signaling
More informationPCS 2000 CONTROLLER USER GUIDE PCS 2000 CONTROLLER. Contents
PCS 2000 CONTROLLER Contents Basic Operations... 2 Controller s Faceplate... 2 Turning the Controller On and Off... 3 Operating the A-Valve and B-Valve Manually... 3 Reading Reports and Program Functions...
More informationPC15CP PUMP CONTROLLER
Phone: 800-669-1303 or 801-561-0303 Fax: 801-255-2312 e-mail: treborservice@idexcorp.com PC15CP PUMP CONTROLLER Operation / Maintenance Manual SERIAL NUMBER (located on top of product): PATENTS: 06/22/12
More informationTIMER CONTROLLED DRAINS
FLUIDRAIN EZ-1 TEC-11 TEC-44 COMBO-D-LUX HIGH PRESSURE ENVIRONMENT DRAIN FLEXIBLITY SAFEGUARD RELIABLE COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS TIMER CONTROLLED DRAINS Condensate
More informationService Data Vickers. Piston Pumps. PVH98/106 Variable Displacement Piston Pump - 11 Design M-2208-S. Revised 05/01/97
Service Data Vickers Piston Pumps PVH98/106 Variable Displacement Piston Pump - 11 Design Revised 05/01/97 M-2208-S Maximum Adjustable Stop S Option 913341 Locknut Torque 25-50 N.m. (18-37 lb. ft.) Torque
More informationMULTI-STAGE, MULTI-FUNCTION AND MODULAR INTERMEDIATE VACUUM MODULES SERIES MI
MULTI-STAGE, MULTI-FUNCTION AND MODULAR INTERMEDIATE VACUUM MODULES SERIES MI Intermediate modules are non-independent multi-stage and multi-function vacuum generators to be assembled to the generators
More informationHodge Clemco Ltd. MJC Mini Cartridge Filters Owners Manual. TSOM 556 Date of issue 13/07/04. Hodge Clemco Ltd
1 MJC Mini Cartridge Filters Owners Manual TSOM 556 Date of Issue: 13.07.04 Orgreave Drive, Sheffield South Yorkshire. S13 9NR Tel:0114 254 0600 Fax: 0114 2540250 Email:sales@hodgeclemco.co.uk www.hodgeclemco.co.uk
More informationRQE Series Temperature Controllers
RQE Series Temperature Controllers For more than 45 years, Thermal Care has manufactured industrial temperature control equipment with the best available component technologies. Our RQE Series mold temperature
More information! WARNING. Before using product, read and understand instructions.
Installation & Maintenance Instructions MM-60C) Series FS4-3 General Purpose Liquid Flow Switch specified models only) Now with Stainless Steel Paddles OPERATION This control is an independently mounted
More informationcutting systems We Bring Intelligence to the Table.TM Victor Thermal Dynamics introduces
automated plasma cutting systems CUTMAsTER Victor Thermal Dynamics introduces A-series The Cutmaster A-Series is the intelligent solution for economical and flexible plasma cutting with the proven reliability
More information3480/RCH SERIES INSTALLATION INSTRUCTIONS
3480/RCH SERIES INSTALLATION INSTRUCTIONS NOTE: If plaster frame is required for installation order it as an option. ATTENTION: Read carefully before attempting to install or operate the heater. GENERAL
More information