MiniPEK sand, oil and fuel trap Installation, use and maintenance instructions

Size: px
Start display at page:

Download "MiniPEK sand, oil and fuel trap Installation, use and maintenance instructions"

Transcription

1 sand, oil and fuel trap Installation, use and maintenance instructions 02BI01_e 06/16

2 02BI01_e Contents 1 GENERAL INFORMATION IMPORTANT INFORMATION ON THE TRAP HANDLING THE TRAP MINIPEK SAND, OIL AND FUEL TRAP OPERATING PRINCIPLE STRUCTURE INSTALLATION INSTRUCTIONS MAINTENANCE SEPARATOR COVERS A PART OF THE SYSTEM IS DAMAGED OR BROKEN PRODUCT RECYCLING AND DISPOSAL MAINTENANCE JOURNAL TEMPLATE... 9 WAVIN-LABKO OY 2(12)

3 1 GENERAL INFORMATION This manual explains the installation, use and maintenance of the Labko MiniPEK sand, oil and fuel trap. The traps are intended for indoor use, e.g. in boiler, auxiliary power and compressor rooms. MiniPEK traps must not be used on vehicle washing sites. MiniPEK traps are CE-marked in accordance with the EU regulation on construction products. 1.1 Important information on the trap These installation instructions are general instructions, which means that every installation must be designed site-specifically and separately in cooperation with the designer and the authorities. The design of the trap must observe section D1 Water supply and drainage installations for buildings. Regulations and guidelines 2007 of the National Building Code of Finland. In order for the system to function to the best of its ability, please read this installation, use and maintenance manual carefully and pay special attention to the following issues during installation in order to ensure occupational safety and the proper functioning of the system: Handle the trap carefully; do not roll or drop it. Secure the trap carefully for transport so that it is not damaged. Inspect the trap immediately for any damage during transport once you have reached the installation site. The trap must be subjected to regular inspections and maintenance measures in order to ensure reliable, good operation. Regular maintenance also ensures the best purifying results. Determine the municipality s waste management requirements for sludge management, and act accordingly. When performing maintenance tasks on parts in contact with wastewater, you should pay attention to the proper protective equipment and hygiene. In order to prevent accidents, covers must be kept in place at all times! It is always the responsibility of the property owner to ensure that nothing or no one can fall into the tank (children, animals, etc.)! 1.2 Handling the trap Handle the trap carefully. You must not roll or drop the trap. Secure the trap for transport, so that it is not damaged. Inspect the trap for any damage prior to installation. WAVIN-LABKO OY 3(12)

4 2 MINIPEK SAND, OIL AND FUEL TRAP 2.1 Operating principle The MiniPEK trap collects water from the designated area and then leads it to further processing. The trap separates sand, oil and other solids from the water. The products must not be used on vehicle washing sites. 2.2 Structure MiniPEK traps are floor drains made from PE plastic. The trap includes a Ø 300 cover, a separate, easily emptied sludge bucket, and a tight Fix lock outlet fitting and an inlet fitting equipped with a drain trap. In addition, the trap has two reinforcement bar installation cogs that can be used to attach the trap to the concrete reinforcements of the floor before casting. Delivered in a protective cover bag that prevents spatter from sticking to the cover during casting. The traps can be equipped with an oil tank filling alarm. MiniPEK 0.2 MiniPEK S 0.4 MiniPEK 0.4 MiniPEK Frame PE PE PE PE 2 Cover Ø300 Rainwater, B125 (C250) Solid, C250 Rainwater, B125 (C250) Rainwater, B125 (C250) 3 Outlet fitting D110 D110 D110 D110 4 Slot for an inlet fitting D110 D110 D110 D110 5 Sludge bucket Ø 260 H = 240 Ø 260 H = 240 Ø 260 H = ACCESSORY: Oil alarm V1 V2 hl Oil and fuel separation tank Sand and sludge storage capacity Outlet elevation fitting h Inlet fitting elevation If ordered If ordered If ordered If ordered 110 l 220 l 220 l 330 l 40 l 80 l 120 l H1 Overall height ,100 W Width L Length 800 1,060 1,060 1,060 Image 1 and table 1. Structure of the MiniPEK traps. WAVIN-LABKO OY 4(12)

5 3 INSTALLATION INSTRUCTIONS Perform trap groundwork in accordance with the site designer s instructions. Please perform the sealing carefully. Position the trap into place onto the correct elevation measured from the upper surface of the covers, as specified in the plan. The trap may be installed deeper than the standard depth, if necessary. Cut the trap according to the image (saw between the lines), add the smooth D315 pipe as an elevation piece, and add mass sealer to the top and bottom ends. Cut place between the lines WAVIN-LABKO OY 5(12)

6 Next, open the inlet fitting if it is to be used. After positioning, support the trap so that it stays in place during casting. Continue the groundwork on site in accordance with the site designer s instructions, including the installation of HVAC pipes, soil densification, sealing and concrete reinforcement. WAVIN-LABKO OY 6(12)

7 Put the cover in the plastic bag, put the cover in place on top of the trap and hold in place during casting. WAVIN-LABKO OY 7(12)

8 4 MAINTENANCE MiniPEK traps must be subjected to regular inspections and maintenance measures in order to ensure reliable and good operation. Regular maintenance also ensures the best purifying results. It is recommended that inspections, emptying and other measures are logged into a maintenance journal, along with all maintenance operations and fault situations as well as operations during fault situations. A maintenance journal template is given in section 6. Use and maintenance instructions must be stored on the premises and presented to the authorities upon request. The property owner may perform the inspections themselves. 4.1 Separator Monitor the sludge and oil level in the trap. The sludge must be removed when necessary, and we recommend that this be done at least twice a year. Regular emptying at sufficiently short intervals prevents sand from entering the sewage pipes and diminishes any unpleasant odours. The surface layer accumulating on the trap is hazardous waste. It must be transported properly to a waste management site accepting hazardous waste. Fill the trap with water after maintenance. The condition and functionality of the trap structures must be inspected at least every ten years. We recommend that the inspection be carried out in connection with trap system maintenance. The trap tightness and the condition of the covers must be inspected. 4.2 Covers The mechanical condition of the covers must be inspected for any rust damage. The inspections ensure that the trap structures are intact. Inspecting structural soundness is carried out in connection with emptying. 4.3 A part of the system is damaged or broken Please contact the product seller if any part of the system has been damaged or broken. 5 PRODUCT RECYCLING AND DISPOSAL The transport packaging of the product can be processed as waste-to-energy. Intact products may be cleaned and recycled for re-use when they are no longer needed. Any product taken out of use must be disposed of in accordance with the current regulations and instructions. Check the current disposal instructions from the local waste management company. WAVIN-LABKO OY 8(12)

9 6 MAINTENANCE JOURNAL TEMPLATE Date Operation Performed by 5 June 14 Separator installed A. Joe 12 October 14 Sludge and oil amount checked Separator cleaned A. Joe / E. Emptier 4 May 15 Sludge and oil amount checked Separator cleaned A. Joe / E. Emptier WAVIN-LABKO OY 9(12)

10 Notes and contact details: Name and contact information Wastewater system designer Wastewater system constructor Property owner Wastewater system maintenance person Precipitation tank emptier WAVIN-LABKO OY 10(12)

11 Notes: WAVIN-LABKO OY 11(12)

12 Wavin-Labko Oy Visiokatu 1 FIN Tampere Tel info@wavin-labko.fi Wavin-Labko Oy Wavin-Labko reserves the right to make alterations without prior notice. Due to continuous product development, changes in technical specifications may occur.

EuroPEK Oil Separator

EuroPEK Oil Separator www.wavin-labko.fi WAVIN-LABKO LTD Labkotie 1 FIN-36240 KANGASALA Tel: +358 20 1285 270 Fax: +358 20 1285 280 E-mail: tanks@wavin-labko.fi 01/04 EuroPEK Oil Separator Instructions for Installation, Operation

More information

EuroPEK Roo Oil Separator

EuroPEK Roo Oil Separator www.wavin-labko.fi WAVIN-LABKO LTD Labkotie 1 FIN-36240 KANGASALA Tel: +358 20 1285 270 Fax: +358 20 1285 280 E-mail: tanks@wavin-labko.fi 01/04 EuroPEK Roo Oil Separator Instructions for Installation,

More information

KESSEL Grease Separator Euro G NG 1, 2 and 4 For underground installation

KESSEL Grease Separator Euro G NG 1, 2 and 4 For underground installation INSTALLATION AND OPERATING INSTRUCTIONS KESSEL Grease Separator Euro G NG 1, 2 and 4 For underground installation KESSEL Grease Separator G according to EN 1825-1 NG 1,2, 4 - for underground installation

More information

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION AND OPERATING INSTRUCTIONS KESSEL Grease Separator G, D and D+S versions Certified under Euro-Norm EN 1825-1 For free standing installation in frost free areas KESSEL Grease separators G,

More information

Integrated Pest Management for School and Municipal Buildings, Appendix: Inspection and Monitoring Forms

Integrated Pest Management for School and Municipal Buildings, Appendix: Inspection and Monitoring Forms http://hdl.handle.net/1813/52291 2012 Community Integrated Pest Management for School and Municipal Buildings, Appendix: Inspection and Monitoring Forms J. Gangloff-Kaufmann, New York State Integrated

More information

Web:

Web: P.O Box - 95466, United Arab Emirates Tel: +971 4 2637073, Mobile: +971 55 2191246, +971 52 864 1667 Email: info@sancouae.com, Web: It's about Peace of mind and a job done right, First time, Every time

More information

KESSEL Grease separator EasyClean free Standard, Direct - oval in NS 2, 4, 7, 10, 15, 20, 25, 30 for set-up in frost-free rooms

KESSEL Grease separator EasyClean free Standard, Direct - oval in NS 2, 4, 7, 10, 15, 20, 25, 30 for set-up in frost-free rooms INSTRUCTIONS FOR INSTALLATION, OPERATION AND MAINTENANCE KESSEL Grease separator EasyClean free Standard, Direct - oval in NS 2, 4, 7, 10, 15, 20, 25, 30 for set-up in frost-free rooms GB Page 1-18 Product

More information

Process engineering. Collection and disposal of commercial food waste ACO Waste-Jet Wet refuse collection system

Process engineering. Collection and disposal of commercial food waste ACO Waste-Jet Wet refuse collection system Collection and disposal of commercial food waste ACO Waste-Jet Wet refuse collection system ACO. The future of drainage. The ACO system chain provides drainage solutions to meet tomorrow s environmental

More information

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions SET-000 Oil/Sludge Alarm Device for Oil Separators Copyright 007 Labkotec Oy We reserve the right for changes without notice TABLE OF CONTENTS GENERAL... INSTALLATION... 4. SET-000 Oil/Sludge Control Unit...

More information

Instructions for Operation and Maintenance of Containers

Instructions for Operation and Maintenance of Containers Instructions for Operation and Maintenance of Containers Container Handling 1. Containers are designed for transport on a flat loading area that is 2.5 m wide, which enables support of the load-bearing

More information

Metos HOT-FILL and SOUS-VIDE pumps and basins

Metos HOT-FILL and SOUS-VIDE pumps and basins Metos HOT-FILL and SOUS-VIDE pumps and basins Productive and ergonomic www.metos.com Hot-Fill Hot-Fill means that food is packed hot minimum 85 C and tight in bags. Then the bags are fast cooled down.

More information

OilSET-1000 (12 VDC)

OilSET-1000 (12 VDC) Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: +358 29 006 260 Fax: +358 29 006 1260 Internet: www.labkotec.fi 20.03.2009 1/11 OilSET-1000 (12 VDC) Oil Separator Alarm Device Copyright 2009

More information

MUD TRAPS MUD TRAPS. Standard version (to install in consolidated sand) Reinforced version (to install in sand)

MUD TRAPS MUD TRAPS. Standard version (to install in consolidated sand) Reinforced version (to install in sand) MUD TRAPS MUD TRAPS Standard version (to install in consolidated sand) Reinforced version (to install in sand) Table of contents What is a mud trap 3 Advantages 3 Characteristics 3 Functioning 3 Installation

More information

Managing your waste. To help businesses get rid of fats, oils, greases and leftover food correctly. Bin it don t block it.

Managing your waste. To help businesses get rid of fats, oils, greases and leftover food correctly. Bin it don t block it. Managing your waste. To help businesses get rid of fats, oils, greases and leftover food correctly. Bin it don t block it. What s the problem? If fats, oils, greases and leftover food go down your drains,

More information

EVAPOCYCLE OWNERS MANUAL

EVAPOCYCLE OWNERS MANUAL EVAPOCYCLE OWNERS MANUAL Introduction. The Aim of this manual to provide information to the property owner or occupant of the land on which an Evapocycle System has been constructed to insure that the

More information

Owners Manual for the Rainmaster Water Recycling System

Owners Manual for the Rainmaster Water Recycling System Owners Manual for the Rainmaster Water Recycling System 22874 Manual.indd 1 4/8/05 8:45:05 AM Rain Master Water Recycling System Welcome! Thank you for purchasing a Rainmaster Water Recycling System. Your

More information

INSTRUCTIONS FOR INSTALLATION AND MANUAL Solid fuel stove for central heating THERMO IN

INSTRUCTIONS FOR INSTALLATION AND MANUAL Solid fuel stove for central heating THERMO IN INSTRUCTIONS FOR INSTALLATION AND MANUAL Solid fuel stove for central heating THERMO IN To respected customer, We are very pleased for your trust and your decision to buy our product. You made a good choice,

More information

AQVA ULTRA Faucet Purifier AQ003-1 User s Guide

AQVA ULTRA Faucet Purifier AQ003-1 User s Guide AQVA ULTRA Faucet Purifier AQ003-1 User s Guide Seller: AQVA Finland Oy Haukilahdenkatu 4 00550 Helsinki 010 321 5080 www.aqva.fi vesi@aqva.fi Read this manual carefully before installation. 1 Contents

More information

DRAINAGE AND SEWAGE. DRENA-LINE Residential Technology

DRAINAGE AND SEWAGE. DRENA-LINE Residential Technology DRAINAGE AND SEWAGE DRENA-LINE Residential Technology 1 HIGH QUALITY IS OUR MISSION The Pentair Group is one of the world leaders in the design and manufacture of innovative products and systems used

More information

Owners Manual For The Rainmaster Water Recycling System

Owners Manual For The Rainmaster Water Recycling System Owners Manual For The Rainmaster Water Recycling System Owners Manual.indd 1 4/8/05 8:58:36 AM Rain Master Water Recycling System Welcome! Thank you for purchasing a Rainmaster Water Recycling System.

More information

CPS Environmental Action Plan

CPS Environmental Action Plan CPS Environmental Action Plan CPS ENERGY & RECYCLING BEST PRACTICES This Energy and Recycling Policy is designed to save resources while supporting the educational mission of the District. The building

More information

NEUTRA grease separators for vege table and animal fat in compliance with EN 1825 and DIN

NEUTRA grease separators for vege table and animal fat in compliance with EN 1825 and DIN NEUTRA grease separators for vege table and animal fat in compliance with EN 1825 and DIN 4040-100 Separating technology A problem that should not be underestimated: Fat in wastewater All vegetable and

More information

BEFORE USING THE REFRIGERATOR PAG. 9 PROTECTING THE ENVIRONMENT PAG. 9 PRECAUTIONS AND GENERAL SUGGESTIONS PAG. 9

BEFORE USING THE REFRIGERATOR PAG. 9 PROTECTING THE ENVIRONMENT PAG. 9 PRECAUTIONS AND GENERAL SUGGESTIONS PAG. 9 GB CONTENTS BEFORE USING THE REFRIGERATOR PAG. 9 PROTECTING THE ENVIRONMENT PAG. 9 PRECAUTIONS AND GENERAL SUGGESTIONS PAG. 9 HOW TO USE THE REFRIGERATOR COMPARTMENT PAG. 10 HOW TO USE THE LOW TEMPERATURE

More information

Technical certificate, instruction for installation and use. Sauna heater VIENYBĖ- P K6M ĮST :2003 ГОСТ

Technical certificate, instruction for installation and use. Sauna heater VIENYBĖ- P K6M ĮST :2003 ГОСТ EN Technical certificate, instruction for installation and use Sauna heater VIENYBĖ- P K6M ĮST 8271432-33:2003 ГОСТ 9817-95 Certificate of acceptance Sauna heater Vienybė - PK6M Prior to installing and

More information

Trade Waste in the Food Industry

Trade Waste in the Food Industry Trade Waste in the Food Industry Trade Waste Bylaw 2008 Contents Introduction... 1 Why is there a need to control the effects of waste discharged from food premises?... 2 Food Premises are required to

More information

inosplit Waste water systems

inosplit Waste water systems INOTEC GmbH We make your construction site easier! inosplit Waste water systems Waste water systems for ecofriendly cleaning of painters and plasterers tools and for treating dirty water in the workshop.

More information

Operating Instructions COOKER HOOD Contents

Operating Instructions COOKER HOOD Contents HDF6.5SAB HDA6.5SAB HDF7.5SAB HDF9.5SAB HDA9.5SAB HDA7.5SAB English Operating Instructions COOKER HOOD Contents Operating Instructions,1 Warnings,7 Installation,9 GLASS controls,10 Maintenance and care,11

More information

Ropox Bathtub. Keep this manual with the product at all times! User Manual & Mounting Instructions PDF 6128 /

Ropox Bathtub. Keep this manual with the product at all times! User Manual & Mounting Instructions PDF 6128 / Ropox Bathtub PDF 6128 / 08.01.2019 User Manual & Mounting Instructions Keep this manual with the product at all times! Contents... 1 Contents... 2 Presale information... 4 General product information...

More information

HEAT RECOVERY AND HEAT AND HUMIDITY RECOVERY AIR HANDLING UNIT

HEAT RECOVERY AND HEAT AND HUMIDITY RECOVERY AIR HANDLING UNIT HEAT RECOVERY AND HEAT AND HUMIDITY RECOVERY AIR HANDLING UNIT S S11 Series SB S11 Series SB -E S11 Series SB -E S11 Series EN OPERATION MANUAL CONTENTS Safety requirements... 2 Purpose... 4 Delivery set...

More information

Bauknecht AG, Industriestrasse 36, 5600 Lenzburg,

Bauknecht AG, Industriestrasse 36, 5600 Lenzburg, Instructions for use UVI 1340/A Bauknecht AG, Industriestrasse 36, 5600 Lenzburg, www.bauknecht.ch Verkauf Telefon 0848 801 002 Fax 0848 801 017 verkauf@bauknecht.ch Kundendienst Telefon 0848 801 001 Fax

More information

M-Tray modular green roof system

M-Tray modular green roof system M-Tray modular green roof system 2017 WALLBARN presents the new M-Tray for 2017 which has been further improved to make sedum roofs easier to install with less disruption to both the plants and the structure.

More information

LONDON GROVE TOWNSHIP MUNICIPAL AUTHORITY FOG PROGRAM BEST MANAGEMENT PRACTICES

LONDON GROVE TOWNSHIP MUNICIPAL AUTHORITY FOG PROGRAM BEST MANAGEMENT PRACTICES 2014 LONDON GROVE TOWNSHIP MUNICIPAL AUTHORITY FOG PROGRAM BEST MANAGEMENT PRACTICES 8/19/2014 TABLE OF CONTENTS WHAT IS FOG 3 WHO MUST COMPLY 4 LEGAL 4 BEST MANAGEMENT PRACTICES 5-11 MAINTENANCE LOG 12

More information

HOW THE RIGHT GREASE INTERCEPTOR CAN HELP YOU SAVE SPACE IN A COMMERCIAL KITCHEN

HOW THE RIGHT GREASE INTERCEPTOR CAN HELP YOU SAVE SPACE IN A COMMERCIAL KITCHEN HOW THE RIGHT GREASE INTERCEPTOR CAN HELP YOU SAVE SPACE IN A COMMERCIAL KITCHEN INTRODUCTION: THE UNCONVENTIONAL KITCHEN Many engineers and architects are all too familiar with this scenario: You ve been

More information

ADDITIONAL INFORMATION FOR RETAIL FOOD PREMISES

ADDITIONAL INFORMATION FOR RETAIL FOOD PREMISES ADDITIONAL INFORMATION FOR RETAIL FOOD PREMISES INTRODUCTION Wastes like cooking oil, grease and food solids are produced by food outlets and services throughout the Timaru District every day. When this

More information

KESSEL Grease separator M NG 2, 4, 7 and 10 For installation in frost free areas With manually automated disposal program

KESSEL Grease separator M NG 2, 4, 7 and 10 For installation in frost free areas With manually automated disposal program INSTALLATION AND OPERATING INSTRUCTIONS KESSEL Grease separator M NG 2, 4, 7 and 10 For installation in frost free areas With manually automated disposal program Version according to DIN 4040-1 or Version

More information

Report number: 0538WF001S. Installation instructions for. Fireplaces

Report number: 0538WF001S. Installation instructions for. Fireplaces Report number: 0538WF001S Installation instructions for Fireplaces 1 TABLE OF CONTENTS GENERAL INFORMATION... 3 IMPORTANT... 3 LOCATION... 3 MANCHESTER FOYER SHALE GREY DIMENSIONS... 4 MANCHESTER FOYER

More information

House Drainage System. Building Utility & Services

House Drainage System. Building Utility & Services House Drainage System Building Utility & Services Syllabus House Drainage: principles of house drainage, pipes and traps, Classification of traps: nahni trap, interception trap, grease-trap, sanitary fittings,

More information

Gaviotas Hydraulic Sleeve pump. Hand pump for deep well

Gaviotas Hydraulic Sleeve pump. Hand pump for deep well Gaviotas Hydraulic Sleeve pump Hand pump for deep well Hydraulic Sleeve Pump Hand pump For deep well Hydraulic Sleeve Pump Installation And operation Manual United Nations Developing Program Centro Las

More information

TECHNICAL WHITE PAPER AUTOMATIC WARNING DEVICES FOR LIGHT LIQUID SEPARATORS

TECHNICAL WHITE PAPER AUTOMATIC WARNING DEVICES FOR LIGHT LIQUID SEPARATORS PROCESS AUTOMATION TECHNICAL WHITE PAPER AUTOMATIC WARNING DEVICES FOR LIGHT LIQUID SEPARATORS Recommendations for the Installation and Operation of Light Liquid Separators This White Paper presents European

More information

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20 INSTALLATION, OPERATION AND MAINTENANCE Ariterm Hybrid 20 TABLE OF CONTENTS General...3 Installation... 4-5 Dimensions - with flue gas exhauster...6 Dimensions - without flue gas exhauster...7 Pipe installations...8

More information

SET-2000 Oil/Sludge 12 VDC

SET-2000 Oil/Sludge 12 VDC Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: + 358 29 006 260 Fax: + 358 29 006 1260 12.2.2015 Internet: www.labkotec.fi 1/14 SET-2000 Oil/Sludge 12 VDC Alarm Device for Oil Separators with

More information

Household waste hatches can accommodate bags sized max 30 litres

Household waste hatches can accommodate bags sized max 30 litres Waste Goes into the Pipe at Kruunuvuorenranta At the new residential area in Kruunuvuorenranta in Helsinki, waste sorted at home travels from block or building-specific hatches along the main pipeline

More information

HL Anti-flooding valves 5/4" DN40 = DN32 = DN32 = DN40 = 280 DN32 DN32 = 350 DN40 DN40 = 350 DN32 = 90 DN40 = 95

HL Anti-flooding valves 5/4 DN40 = DN32 = DN32 = DN40 = 280 DN32 DN32 = 350 DN40 DN40 = 350 DN32 = 90 DN40 = 95 5/4" DN40 = 80-315 DN32 = 80-315 DN40 = 350 DN32 = 350 DN40 = 280 DN32 = 285 29 DN40 DN32 HL Anti-flooding valves DN40 = 50-250 DN32 = 50-220 Basement and backflooding DN40 = 95 DN32 = 90 HL Hutterer &

More information

Daily maintenance and checks

Daily maintenance and checks 5 Daily maintenance and checks This chapter explains about daily maintenance and checks. The information herein is very important towards keeping the equipment regularly in proper working order. 5-1 5.1

More information

Grease disposal concepts. Grease separators. For full and partial disposal For free-standing or ground installation

Grease disposal concepts. Grease separators. For full and partial disposal For free-standing or ground installation Grease separators Grease disposal concepts Grease separators For full and partial disposal For free-standing or ground installation Selecting the correct separator Areas of application Hotels Restaurants

More information

SET Installation and Operating Instructions. Level switch for one sensor

SET Installation and Operating Instructions. Level switch for one sensor Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel.: +358 29 006 260 Fax: +358 29 006 1260 7.11.2013 Internet: www.labkotec.fi 1/14 SET-1000 Level switch for one sensor Copyright 2013 Labkotec Oy

More information

DENMARK RECOMMENDED RETAIL PRICE LIST 2017 IN DKK (INCL. VAT)

DENMARK RECOMMENDED RETAIL PRICE LIST 2017 IN DKK (INCL. VAT) DENMARK RECOMMENDED RETAIL PRICE LIST 2017 IN DKK (INCL. VAT) BLINDS CHAIN OPERATED ROLLER BLINDS (Silent Gliss 4810) [D] D Fabric: Morning 100 3759 3891 4023 4165 4297 4438 4571 4712 4894 4979 5055 5142

More information

DEHUMIDIFIER DT 850 DIRECTIONS FOR INSTALLATION AND USE

DEHUMIDIFIER DT 850 DIRECTIONS FOR INSTALLATION AND USE DEHUMIDIFIER DT 850 DIRECTIONS FOR INSTALLATION AND USE 1 SUMMARY 1. GENERAL..... 3 1.1 General terms of delivery.... 3 1.2 Voltage... 3 1.3 Standards. 3 2. DESCRIPTION.... 3 2.1 Presentation..... 3 2.2

More information

V SERIES Hydraulic Tools

V SERIES Hydraulic Tools V SERIES Hydraulic Tools V SERIES www.stanleyhydraulic.com Hydraulic Tools GREAT BRAND, GREAT TOOLS Stanley Hydraulic Tools has a proud tradition of being a global leader in the development of a wide range

More information

Heat Pumps and Public Swimming Pools, a Perfect Match

Heat Pumps and Public Swimming Pools, a Perfect Match TOPICAL ARTICLE Heat Pumps and Public Swimming Pools, a Perfect Match M. Zuliani, P. Pattijn - Belgium Public swimming pools have a very high energy consumption, due to high demands of heating and climatisation

More information

Best Environmental Management Practices

Best Environmental Management Practices Santa Cruz County Sanitation District 701 OCEAN STREET, SUITE 410, SANTA CRUZ, CA 95060-4073 (831) 454-2160 FAX (831) 454-2089 TDD/TTY- CALL 711 JOHN J. PRESLEIGH, DISTRICT ENGINEER Best Environmental

More information

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC AQB09JJ6WC_IM_E_2585 2006.4.17 4:26 PM Page 17 INSTALLATION MANUAL Indoor Unit AQB09JJWC AQB12JJWC Outdoor Unit UQB09JJWC UQB12JJWC ENGLISH FRANÇAIS ESPAÑOL Split-type Air Conditioner (Cooling and Heating)

More information

ACO Construction & Building Products

ACO Construction & Building Products ACO Construction & Building Products Light oil and sediment separator system ACO Environment Oleopator P Oil Water Separator Operating Guide 1. Installation 2. Initial set-up/commissioning 3. Operation

More information

Electric Hand dryer. Installation and operating manual

Electric Hand dryer. Installation and operating manual Electric Hand dryer Installation and operating manual Do not attempt to install the unit yourself unless you are a trained service technician. Otherwise, this may affect safety and proper functioning of

More information

CLIENT PROJECT. Schematic representation of sludge treatment at WWTP Homburg

CLIENT PROJECT. Schematic representation of sludge treatment at WWTP Homburg S u s t a i n a b l e s e w a g e s l u d g e u t i l i s a t i o n a t t h e H o m b u r g w a s t e w a t e r t r e a t m e n t p l a n t CLIENT The Entsorgungsverband Saar (EVS - Saarland Waste Disposal

More information

www.tournesolsiteworks.com Insert-Style Container Irrigation Systems Installation & Operation Field Manual Table of Contents System Contents 3 The Container Irrigation Cycle 4 Preparation 5 Planting 7

More information

Guide to the Heating and Cooling Systems at McLean Gardens

Guide to the Heating and Cooling Systems at McLean Gardens MCLEAN GARDENS Guide to the Heating and Cooling Systems at McLean Gardens How They Function and Their Maintenance Version 1.0 5/21/2013 This document explains the McLean Gardens heating and cooling system

More information

Fire damper ETPR Instructions for Installation, Operation and Maintenance 10/2016

Fire damper ETPR Instructions for Installation, Operation and Maintenance 10/2016 Instructions for Installation, Operation and aintenance 10/2016 Installation Fire damper ETPR must be installed according to this installation manual, see pages 2-5. Operation and function testing According

More information

AIR FILTER + REGULATOR + LUBRICATOR AIR FILTER. Series : V050, V100, V200, V250, V300

AIR FILTER + REGULATOR + LUBRICATOR AIR FILTER. Series : V050, V100, V200, V250, V300 AIR FILTER + REGULATOR + LUBRICATOR AIR FILTER Series : V00, V00, V00, V0, V00 AIR FILTER FEATURES: High flow Capacity Shatter- Proof polycarbonate bowl with bowl guard Minimum Pressure drop Choice of

More information

TITLE FIVE - Additional Public Services Chap Garbage and Rubbish Collection. Chap City Park. Chap Flood Control.

TITLE FIVE - Additional Public Services Chap Garbage and Rubbish Collection. Chap City Park. Chap Flood Control. 29 TITLE FIVE - Additional Public Services Chap. 971. Garbage and Rubbish Collection. Chap. 973. City Park. Chap. 975. Flood Control. CHAPTER 971 Garbage and Rubbish Collection 971.01 Definitions. 971.02

More information

Grease separator. Chapter contents. Grease separator for freestanding. Separator. Grease separator

Grease separator. Chapter contents. Grease separator for freestanding. Separator. Grease separator Chapter contents Separator for freestanding installation With complete disposal Mobile separator for food stall or marquee Basic design for disposal via the cover Extension stage 1 for disposal via direct

More information

CLASS POWER ENGINEER S CERTIFICATE

CLASS POWER ENGINEER S CERTIFICATE For FIFTH CLASS October 2012 Visit our Website at www.sopeec.org FIFTH CLASS PAGE 2 of 8 GENERAL INFORMATION Introduction: This syllabus has been approved by the Standardization of Power Engineers Examinations

More information

Rain Barrel. Making a EL /14. Figure 1. Example of rain barrel. Brent Clayton, Billy Kniffen and Dotty Woodson*

Rain Barrel. Making a EL /14. Figure 1. Example of rain barrel. Brent Clayton, Billy Kniffen and Dotty Woodson* EL-5518 07/14 Making a Rain Barrel Brent Clayton, Billy Kniffen and Dotty Woodson* R Figure 1. Example of rain barrel. ainwater harvesting is an old-fashioned yet innovative approach to capturing water.

More information

Section C-2 of the Gas Regulations

Section C-2 of the Gas Regulations Section C-2 of the Gas Regulations July 1994 Foreword Foreword Section C-2 of the Gas Regulations were established in accordance with Sections 15, 17 and subsection 2 of Section 19 of Act No. 250 of 8

More information

MANCHESTER FOYER INSTALLATION GUIDE AND OWNER S MANUAL

MANCHESTER FOYER INSTALLATION GUIDE AND OWNER S MANUAL MANCHESTER FOYER INSTALLATION GUIDE AND OWNER S MANUAL TABLE OF CONTENTS GENERAL INFORMATION... 3 IMPORTANT... 3 LOCATION... 3 MANCHESTER FOYER SHALE GREY DIMENSIONS... 4 MANCHESTER FOYER HARVEST GOLD

More information

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC AQB8J6WC_IM_E_25864 2006.4.4 3:29 PM Page 7 INSTALLATION MANUAL Indoor Unit AQB8J6WC AQB24J2WC Outdoor Unit UQB8J6WC UQB24J2WC ENGLISH FRANÇAIS ESPAÑOL Split-type Air Conditioner (Cooling and Heating)

More information

Petrozavodsk Tuija Ahrikkala. Municipal Solid Waste (MSW) Management Kemi-Tornio Region

Petrozavodsk Tuija Ahrikkala. Municipal Solid Waste (MSW) Management Kemi-Tornio Region Petrozavodsk 14.06.2018 Tuija Ahrikkala Municipal Solid Waste (MSW) Management Kemi-Tornio Region Perämeren Jätehuolto Oy = Waste Management of Bothnian Bay Ltd 600 km from Utsjoki to Tornio Municipal

More information

HUBER Belt Dryer BT for sewage sludge drying

HUBER Belt Dryer BT for sewage sludge drying HUBER Belt Dryer BT for sewage sludge drying Dry, granular, disinfected (Class A) biosolids product, easy and safe to handle Exhaust air deodorization Virtually dust-free product Energy-optimized process

More information

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE 2 GLEC-6 - Installation and maintenance CONTENTS 1 Important information... 3 2 Safety notes... 3 3 Technical description...4 4 Transport... 6 5

More information

COOKER HOOD USER HANDBOOK FOR INSTALLATION AND OPERATION MODELS CRC95

COOKER HOOD USER HANDBOOK FOR INSTALLATION AND OPERATION MODELS CRC95 COOKER HOOD USER HANDBOOK FOR INSTALLATION AND OPERATION MODELS CRC95 Your new Cooker Hood Using your new Cooker Hood is very simple. Nevertheless, to get the best results it is important that you read

More information

FIELD SEPTIC DISPOSAL SYSTEM (FSDS) CERTIFICATION STANDARDS COMPLIANCE AS/NZS :1998 REPORT

FIELD SEPTIC DISPOSAL SYSTEM (FSDS) CERTIFICATION STANDARDS COMPLIANCE AS/NZS :1998 REPORT FIELD SEPTIC DISPOSAL SYSTEM (FSDS) CERTIFICATION STANDARDS COMPLIANCE AS/NZS 1546.1:1998 REPORT 1.0 INTRODUCTION 2 My name is Robert Brown, B.Sc. Civ.Eng., and I have been engaged by Humanitarian Environmental

More information

ORDER OF AN EXECUTIVE OFFICER

ORDER OF AN EXECUTIVE OFFICER Environmental Public Health ORDER OF AN EXECUTIVE OFFICER To: 1455878 Alberta Ltd. 1458268 Alberta Ltd. 1458128 Alberta Ltd. Chi Lung (Kelvin) Chan Paul Chao Sai No (Ringo) Chan RE: The food establishment

More information

OPTIMUM 700 PASTA COOKER ELECTRIC BUILDER S SPECIFICATIONS. Part A: Technical characteristics Part B: Technical instructions for the installer

OPTIMUM 700 PASTA COOKER ELECTRIC BUILDER S SPECIFICATIONS. Part A: Technical characteristics Part B: Technical instructions for the installer OPTIMUM 700 PASTA COOKER ELECTRIC BUILDER S SPECIFICATIONS Part A: Technical characteristics Part B: Technical instructions for the installer WARNING Installation and repairs must be carried out by personnel

More information

Hitachi Room Air Conditioner "Stainless Clean Shirokuma-kun" Premium X Series has launched

Hitachi Room Air Conditioner Stainless Clean Shirokuma-kun Premium X Series has launched September 6, 2017 Johnson Controls-Hitachi Air Conditioning Automatic Cleaning of Heat Exchanger through "Frost Wash" to Wash Away Dust and Mold Through Freezing and Rapid Melting Process Hitachi Room

More information

en-us Use and Care Manual, Installation Instructions Washer WAT28400UC

en-us Use and Care Manual, Installation Instructions Washer WAT28400UC en-us Use and Care Manual, Installation Instructions Washer WAT28400UC Under counter (Less Desirable) If front of the appliance is covered ventilation openings must be installed. E & F are minimum area

More information

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

OilSET Installation and Operating Instructions. Oil Separator Alarm Device Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: +358 29 006 260 Fax: +358 29 006 1260 18.11.2010 Internet: www.labkotec.fi 1/10 OilSET-1000 Oil Separator Alarm Device Copyright 2010 Labkotec

More information

INFO 3/2015. NEWS WC connectors Bronze program Industrial stainless steel drainage system Swimming pool overflow radius gratings.

INFO 3/2015. NEWS WC connectors Bronze program Industrial stainless steel drainage system Swimming pool overflow radius gratings. INFO 3/2015 www.alcaplast.com S WC connectors Bronze program Industrial stainless steel drainage system Swimming pool overflow radius gratings WC CONNECTORS flexible cuff to connect the outlet and WC pans

More information

USER S MANUAL DN-2. Drain pump

USER S MANUAL DN-2. Drain pump USER S MANUAL DN-2 CONTENTS Safety requirements... 2 Purpose... 3 Delivery set... 3 Technical data... 3 Design... 4 Installation and set-up... 5 Connection to power mains... 8 Storage and transportation

More information

PRESSURE SEWER SYSTEMS GUIDE FOR HOME OWNERS AND BUILDERS

PRESSURE SEWER SYSTEMS GUIDE FOR HOME OWNERS AND BUILDERS PRESSURE SEWER SYSTEMS GUIDE FOR HOME OWNERS AND BUILDERS VERSION: 1.0 VERSION: 1.0 Pressure Sewer Hydraulic Design Guidelines 1 Version: 1.0 Page 1 of 15 Contents 1 Introduction... 4 Pressure Sewer System

More information

CRISTAL Built-in Dish Sterilizer Instruction Manual

CRISTAL Built-in Dish Sterilizer Instruction Manual CRISTAL Built-in Dish Sterilizer Instruction Manual Model No.: D36DSS Version Number: 01 Revision Date: September 2014 Dear user: Thank you for your purchase of CRISTAL built-in dish sterilizer! Please

More information

USER S MANUAL NKP. Duct heater for supply air pre-heating with external control

USER S MANUAL NKP. Duct heater for supply air pre-heating with external control USER S MANUAL Duct heater for supply air pre-heating with external control CONTENTS Contents... 2 Safety requirements... 2 Purpose... 4 Delivery set... 4 Designation key... 4 Technical data... 5 Design

More information

TECHNICAL INFORMATION

TECHNICAL INFORMATION MAKE YOUR OWN COMPOST - SIMPLE AND PRACTICAL It is simple and practical because the most unpleasant fraction of the waste stream - the food waste, is being dealt with hygienically daily. You empty your

More information

VETO CLEANER 500 FLUE GAS CLEANER

VETO CLEANER 500 FLUE GAS CLEANER As of serial number 3100 0001 VETO CLEANER 500 FLUE GAS CLEANER USER MANUAL SPARE PARTS LIST Manufacturer: ALA TALKKARI Veljekset Ala-Talkkari Oy FI-62130 HELLANMAA TEL. +358 6 433 6333 FAX +358 6 437

More information

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit DC Heat Recovery Unit MVHR Wholehouse heat recovery unit Stock Ref. N DC Heat Recovery Unit MVHR 443423 Installation, Maintenance & Users Instructions PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

More information

HEAT PUMPS AND PUBLIC SWIMMING POOLS, A PERFECT MATCH

HEAT PUMPS AND PUBLIC SWIMMING POOLS, A PERFECT MATCH Proceedings of the REHVA Annual Meeting Conference https://www.rehvam2018atic.eu/ HEAT PUMPS AND PUBLIC SWIMMING POOLS, A PERFECT MATCH Matthias Zuliani 1, Pedro Pattijn 1 1 Ingenium NV, Antwerp/Bruges/Ghent/Leuven,

More information

Toaster User's manual

Toaster User's manual Toaster User's manual EN STS 30WH / STS 31GR / STS 32BL STS 33OR / STS 34RD / STS 35VT STS 36YL / STS 37GG / STS 38RS Prior to using this appliance, please read the user's manual thoroughly, even in cases,

More information

Plus Perimeter Aspiration Timer Remote control predisposition

Plus Perimeter Aspiration Timer Remote control predisposition Island Plus Perimeter Aspiration Timer Remote control predisposition Features Installation Finish Controls N. Motors Portata Max Recycling Max Noise Level Min Noise Level Total Absorption Dimensions Lighting

More information

FLUE GAS TEMPERATURES OF FIREPLACES

FLUE GAS TEMPERATURES OF FIREPLACES TAMPERE UNIVERSITY OF TECHNOLOGY FIRE LABORATORY RESEARCH REPORT NO. PALO 2133/2012 FLUE GAS TEMPERATURES OF FIREPLACES Tampere 2012 1 (42) 42 pages Financiers Fire Protection Fund Ministry of the Interior

More information

D-TECT 3 IP. GJD260 IP Motion Detector

D-TECT 3 IP. GJD260 IP Motion Detector D-TECT 3 IP GJD260 IP Motion Detector PACKAGE CONTENTS 1 x D-TECT 3 IP 1 x Drilling template for fixing holes 3 x 31.75mm wall plugs 3 x 31.75mm screws 2 x Spare sliding curtains 2 x Tamper feet 1 x Tamper

More information

WHY TRIPLE RINSING? AGROCHEMICAL CONTAINERS

WHY TRIPLE RINSING? AGROCHEMICAL CONTAINERS WHY TRIPLE RINSING? AGROCHEMICAL CONTAINERS What do you do with the empty agrochemical containers after you have finished your agrochemical application? No matter how an empty pesticide container is disposed

More information

Feels like home. Unlimited Capacity Odour free Easy handling Waterless. Comfort wherever you are. Environmentally friendly

Feels like home. Unlimited Capacity Odour free Easy handling Waterless. Comfort wherever you are.  Environmentally friendly Unlimited Capacity Odour free Easy handling Waterless Environmentally friendly Feels like home Comfort wherever you are Separett VILLA 5-year guarantee www.separett.com 5-year guarantee Child Seat Included

More information

Compaction versus the value of airspace: Solid Waste Compaction in Sanitary Landfills

Compaction versus the value of airspace: Solid Waste Compaction in Sanitary Landfills Compaction versus the value of airspace: Solid Waste Compaction in Sanitary Landfills Author: Stéphane BERTRAND CATERPILLAR Europe, Africa and the Middle East. Industrial and Waste applications specialist

More information

Cooker Hood CHIM60 CHIM70 CHIM90 CHIM101 CHIM110. Installation & User s instructions

Cooker Hood CHIM60 CHIM70 CHIM90 CHIM101 CHIM110. Installation & User s instructions Cooker Hood CHIM60 CHIM70 CHIM90 CHIM101 CHIM110 Installation & User s instructions 2 250 20.5 167.5 A 590 : 960 260 330 Max 370 E F 304 278 42 206 167 Z B C D 230 230 Fig.1 Fig.3 G E A Z Z F B Y C D 490

More information

Index BEFORE USING THE APPLIANCE Safety Instructions... 2 Recommendations... 3 Switching On the Appliance... 4 HOW TO OPERATE THE FREEZER...

Index BEFORE USING THE APPLIANCE Safety Instructions... 2 Recommendations... 3 Switching On the Appliance... 4 HOW TO OPERATE THE FREEZER... Index BEFORE USING THE APPLIANCE... 2 Safety Instructions... 2 Recommendations... 3 Switching On the Appliance... 4 HOW TO OPERATE THE FREEZER... 5 Thermostat Setting... 5 Display Panel... 5 FOOD STORAGE

More information

PUTTART VERTICAL DRYER-GRANULATOR SLUDGE DRYING AND GRANULATING IN ONE

PUTTART VERTICAL DRYER-GRANULATOR SLUDGE DRYING AND GRANULATING IN ONE PUTTART VERTICAL DRYER-GRANULATOR SLUDGE DRYING AND GRANULATING IN ONE SLUDGE DRYING AND GRANULATING IN ONE Sludge, the by-product of wastewater treatment, consists of a concentrated mix of solids in liquid

More information

SET-2000 Hi Level/Oil

SET-2000 Hi Level/Oil Labkotec Oy Labkotie 1 FI-36240 KANGASALA FINLAND Tel: + 358 29 006 260 Fax: + 358 29 006 1260 13.03.2008 Internet: www.labkotec.fi Alarm Device for Oil Separators Copyright 2008 Labkotec Oy We reserve

More information

RONDA 200. RONDA 200 when life is too short for hobby vacuum cleaners OTHER MACHINES FOR SIMILAR PURPOSES RONDA 20 RONDA 400

RONDA 200. RONDA 200 when life is too short for hobby vacuum cleaners OTHER MACHINES FOR SIMILAR PURPOSES RONDA 20 RONDA 400 vacuum cleaners for the construction industry RONDA 200 RONDA 200 when life is too short for hobby vacuum cleaners Green Tech An CAP motor with improved suction performance and lower power consumption

More information

AFTER SALES SERVICE DIV. SM 21

AFTER SALES SERVICE DIV. SM 21 AFTER SALES SERVICE DIV. SM 21 CONTENTS 1. Trouble about refrigerant piping work (Page) 1-1) Trouble on cutting copper tubes!! 1(above) 1-2) Problem of storage of copper tubes!! 1(below) 1-3) Trouble caused

More information

Air handling unit. BlauAir RH USER S MANUAL

Air handling unit. BlauAir RH USER S MANUAL Air handling unit EN USER S MANUAL CONTENTS Safety requirements... 2 Purpose... 4 Delivery set... 4 Designation key... 4 Technical data... 5 Unit design and operation logic... 7 Installation and set-up...

More information

Vacuum cleaner Instruction manual

Vacuum cleaner Instruction manual CSR Tools & Consumables Triniti 3, Level 5 39 Delhi Road North Ryde NSW 23 Australia http://www.csr.com.au Vacuum cleaner Instruction manual IMPORTANT: Read and understand all instructions before using.

More information