Preface USER MANUAL. Copyright Reserved Autonics Co., Ltd. I

Size: px
Start display at page:

Download "Preface USER MANUAL. Copyright Reserved Autonics Co., Ltd. I"

Transcription

1 Preface USER MANUAL Copyright Reserved Autonics Co., Ltd. I

2 Preface II Copyright Reserved Autonics Co., Ltd.

3 Preface Preface Thank you for purchasing an Autonics product. Please familiarize yourself with the information contained in the Safety Precautions section before using this product. This user manual contains information about the product and its proper use, and should be kept in a place where it will be easy to access. Copyright Reserved Autonics Co., Ltd. III

4 User Manual Guide User Manual Guide Please familiarize yourself with the information in this manual before using the product. This manual provides detailed information on the product's features. It does not offer any guarantee concerning matters beyond the scope of this manual. This manual may not be edited or reproduced in either part or whole without permission. A user manual is not provided as part of the product package. Visit our web site ( to download a copy. The manual's content may vary depending on changes to the product's software and other unforeseen developments within Autonics, and is subject to change without prior notice. Upgrade notice is provided through out homepage. We contrived to describe this manual more easily and correctly. However, if there are any corrections or questions, please notify us these on our homepage. IV Copyright Reserved Autonics Co., Ltd.

5 User Manual Symbols User Manual Symbols Symbol Description Supplementary information for a particular feature. Failure to follow instructions can result in serious injury or death. Failure to follow instructions can lead to a minor injury or product damage. 1 Annotation mark. An example of the concerned feature's use. Copyright Reserved Autonics Co., Ltd. V

6 Safety Considerations Safety Considerations Following these safety precautions will ensure the safe and proper use of the product and help prevent accidents, as well as minimizing possible hazards. Safety precautions are categorized as Warnings and Cautions, as defined below: Warning Failure to follow the instructions may lead to a serious injury or accident. Caution Failure to follow the instructions may lead to a minor injury or accident. Fail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic loss. (e.g. nuclear power control, medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, etc.) Failure to follow this instruction may result in fire, personal injury, or economic loss. Install on a device panel to use. Failure to follow this instruction may result in fire. Do not connect, repair, or inspect the unit while connected to a power source. Failure to follow this instruction may result in fire. Check 'Connections' before wiring. Failure to follow this instruction may result in fire. Do not disassemble or modify the unit. Failure to follow this instruction may result in fire. When connecting the power input and relay output, use AWG 26 to 12cable, and connecting the sensor input and communication cable without dedicated cable, use AWG 28 to 14cable. Failure to follow this instruction may result in fire or malfunction due to contact failure. Use the unit within the rated specifications. Failure to follow this instruction may result in fire or product damage. Use dry cloth to clean the unit, and do not use water or organic solvent. Failure to follow this instruction may result in electric shock or fire. Do not use the unit in the place where flammable/explosive/corrosive gas, humidity, direct sunlight, radiant heat, vibration, impact, or salinity may be present. Failure to follow this instruction may result in fire or explosion. Keep metal chip, dust, and wire residue from flowing into the unit. Failure to follow this instruction may result in fire or product damage. VI Copyright Reserved Autonics Co., Ltd.

7 Caution during Use Caution during Use Follow instructions in 'Cautions during Use'. Otherwise, It may cause unexpected accidents. Check the polarity of the terminals before wiring the temperature sensor. For RTD temperature sensor, wire it as 3-wire type, using cables in same thickness and length. For thermocouple (CT) temperature sensor, use the designated compensation wire for extending wire. Keep away from high voltage lines or power lines to prevent inductive noise. In case installing power line and input signal line closely, use line filter or varistor at power line and shielded wire at input signal line. Do not use near the equipment which generates strong magnetic force or high frequency noise. Do not apply excessive power when connecting or disconnecting the connectors of the product. Install a power switch or circuit breaker in the easily accessible place for supplying or disconnecting the power. Do not use the unit for other purpose (e.g. voltmeter, ammeter), but temperature controller. When changing the input sensor, turn off the power first before changing. After changing the input sensor, modify the value of the corresponding parameter. Power supply should be insulated and limited voltage/current or Class 2, SELV power supply device. Do not overlapping communication line and power line. Use twisted pair wire for communication line and connect ferrite bead at each end of line to reduce the effect of external noise. Make a required space around the unit for radiation of heat. For accurate temperature measurement, warm up the unit over 20 min after turning on the power. Make sure that power supply voltage reaches to the rated voltage within 2 sec after supplying power. Do not wire to terminals which are not used. Install DIN rail vertically from the ground. This unit may be used in the following environments. 1Indoors (in the environment condition rated in 'Specifications') 2Altitude max. 2,000m 3Pollution degree 2 4Installation category II The above specifications are subject to change and some models may be discontinued without notice. Be sure to follow cautions written in the instruction manual, user manual and the technical descriptions (catalog, homepage). Copyright Reserved Autonics Co., Ltd. VII

8 Caution during Use VIII Copyright Reserved Autonics Co., Ltd.

9 Table of Contents Table of Contents Preface... 3 User Manual Guide... 4 User Manual Symbols... 5 Safety Considerations... 6 Caution during Use... 7 Table of Contents Product Introduction Features Components and accessories Models Model list and descriptions Parts and features Front parts Other parts Specifications Dimensions Installation Connector connection Module connection Mounting with bolts Mounting on DIN rail Connections and Insulation Block Diagram TM2 Series TM4 Series Wiring precautions Sensor connection Power supply connection Communication line wiring Module connection Preparation and Startup General process Setup values when power ON Temperature control examples Single module Multiple modules Parameter Settings and Functions Input Input type and temperature range Input type Copyright Reserved Autonics Co., Ltd. IX

10 Table of Contents Input temperature sensor unit Input correction Input digital filter SV high/low-limit value Control output Control output operation mode Deadband/Overlap band MV high/low-limit value Ramp function Auto/Manual control Manual control baseline MV Manual control initial MV Control output Temperature control Temperature control method ON/OFF control PID control Auto-tuning Alarm output Alarm output target channel Alarm output operating mode Alarm output option Alarm SV Alarm output hysteresis Alarm output method Alarm output delay Loop break alarm(lba) Sensor break alarm Heater burnout alarm Alarm output OFF Alarm output examples Communications Communication address Communications speed settings Communications parity bit Communication stop bit Response wait time Enable/Disable communications writing USB-to-Serial connection Monitoring function Control output MV monitoring Heating MV monitoring Cooling MV monitoring Heater current monitoring Run/Stop function Control output for STOP Alarm output for STOP Multi SV X Copyright Reserved Autonics Co., Ltd.

11 Table of Contents Number of multi SVs Multi SV No. settings SV for Multi SVs Digital input Digital input terminal settings Digital input terminal target channel Error Sensor error, MV setting Parameter initialization Simple Error Diagnosis Error display Trobleshootings DAQMaster Overview Features Copyright Reserved Autonics Co., Ltd. XI

12 Table of Contents XII Copyright Reserved Autonics Co., Ltd.

13 1 Product Introduction 1 Product Introduction 1.1 Features TM Series module type temperature controller realizes high-speed controlling with superior sampling cycle (TM4 100 ms, TM2 50 ms). Side connector connection makes less wiring work and close mounting possible for up to 31 units without additional power and communication wires for expansion modules. PC parameter setting and monitoring is possible via RS485 communication or dedicated USB cable. In addition, more reliable temperature controlling can be realized via various convenient functions. Multi channels (4-CH/2-CH) simultaneous controlling possible Each channel insulated Dielectric strength 1,000VAC No communication and power supply for expansion modules required using module connectors : Up to 31 module (124 channels/62 channels) expansion possible High-speed sampling cycle (100ms/50ms) Heating/Cooling simultaneous controlling Heater burn-out detection via a current transformer (CT). PC parameter setting via PC (USB cable and RS485 communication) : Supports comprehensive device management program (DAQMaster) Communication coverter, sold separately : SCM-WF48 (Wi-Fi to RS485 USB wireless communication converter), SCM-US48I (USB to RS485 converter), SCM-38I (RS232C to RS485 converter), SCM-US (USB to serial converter) : Enables to set parameters via SCM-US which does not required supplying power and wiring Easy maintenance via connector type connection : Sensor input connector, control output connector, power/communication connector Multi-input/multi-range Heater disconnection alarm (CT function) CT, sold separately: CSTC-E80LN, CSTC-E200LN, CSTS-E80PP Copyright Reserved Autonics Co., Ltd. 13

14 1 Product Introduction 1.2 Components and accessories (1) Components Make sure all listed components are included with your product before use. If any components are missing or damaged, please contact our sales department or your dealer. Note that power supply/communications connectors are provided with basic modules only. (2) Accessories (sold separately) Communication converter SCM-WF48 (Wi-Fi to RS485 USB wireless communication converter) SCM-US48I (USB to RS485 converter) SCM-38I (RS232C to RS485 converter) SCM-US (USB to Serial converter) 14 Copyright Reserved Autonics Co., Ltd.

15 1 Product Introduction Current transformer(ct) CSTC-E80LN Max. load current: 80A(50/60Hz) Max. load current for TM Series is 50A. Current ratio: 1/1000 Wire wounded resistance: 31Ω±10% (unit: mm) Copyright Reserved Autonics Co., Ltd. 15

16 1 Product Introduction CSTC-E200LN Max. load current: 200A(50/60Hz) Max. load current for TM Series is 50A. Current ratio: 1/1000 Wire wounded resistance: 20Ω±10% (unit: mm) 16 Copyright Reserved Autonics Co., Ltd.

17 1 Product Introduction CSTS-E80PP Max. load current: 80A (50/60Hz) Max. load current for TM Series is 50A. Current ratio: 1/1000 Wire wounded resistance: 31Ω ±10% (unit: mm) For using CT, do not supply first part current when opening CT output. It occurs high voltage at CT output part. Using current of above CTs are same as 50A. But be sure that inner hole sizes are different. Select it properly for the environment. Copyright Reserved Autonics Co., Ltd. 17

18 1 Product Introduction Display unit DS/DA-T Series (RS485 communication input type display unit) Connect RS485 communication input type display unit (DS/DA-T Series) and TM Series, the display unit displays present value of the device without PC/PLC. Images of components and accessories may differ from actual products. For more information about any of the above products, please refer to the concerned product's user manual. Visit our website ( to download it. 18 Copyright Reserved Autonics Co., Ltd.

19 1 Product Introduction 1.3 Models TM 4 - N 2 R B Category Description 1 Model TM Multi-channel modular temperature controller 2 Channels 3 Auxiliary input/output 2-channel 2 2-channel 4 4-channel 2 4 CT input, Digital input (DI-1, DI-2), Alarm output 1/2, RS485 communication output CT input, Digital input (DI-1, DI-2), Alarm output 1/2/3/4, RS485 communication output 4-channel N RS485 communication output 4 Power supply 2 24 VDC 5 Control output 6 Module type 2-channel 4-channel R C R S B Relay output Selectable current or SSR drive output Relay output SSR drive output Basic module E Expansion module 1 1. The expansion module does not supply power/comm. terminal. Order it with the basic module. Copyright Reserved Autonics Co., Ltd. 19

20 1 Product Introduction Model list and descriptions TM2 Series TM4 Series Model Name TM2-22RB TM2-22CB TM2-42RB TM2-42CB TM2-22RE TM2-22CE TM2-42RE TM2-42CE TM4-N2RB TM4-N2SB TM4-N2RE TM4-N2SE Control Output Relay output Current or SSR drive output Relay output Current or SSR drive output Relay output Current or SSR drive output Relay output Current or SSR drive output Relay output SSR drive output Relay output SSR drive output Option Input/Output Input Output Alarm 1/2, RS485 comm. output CT input, Digital input (DI-1, DI-2) Alarm 1/2, RS485 comm. output Alarm 1/2/3/4, RS485 comm. output Alarm 1/2/3/4, RS485 comm. output Alarm 1/2, RS485 comm. output Alarm 1/2, RS485 comm. output Alarm 1/2/3/4, RS485 comm. output Alarm 1/2/3/4, RS485 comm. output - RS485 comm. output Structure Basic module Expansion module Basic module Expansion module 20 Copyright Reserved Autonics Co., Ltd.

21 1 Product Introduction 1.4 Parts and features Front parts Sensor input connector Control output connector Power/Comm. terminal [only for basic module (TM - 2 B)] Suppling power to basic/expansion modules and communicating with over 1 module (s). PC loader port: It is the PC loader port for serial communication between one module and PC to set parameter and monitoring by DAQMaster. Use this for connecting SCM-US (USB to serial converter, sold separately). When using PC loader port (connecting SCM-US), communication via power/comm. terminal is blocked and monitoring is not available 5 Indicators TM2 Series Status Initial power ON 1 Indicator Control output Alarm output N.O. (Normally Open) N.C. (Normally Closed) OFF(OPEN) ON(CLOSE) OFF(CLOSE) ON(OPEN) PWR (green) 3 ON ON ON CH1 (red) Flashes (2,400bps) ON Flash CH2 (red) Flashes (4,800bps) ON Flash AL1 (yellow) Flashes (9,600bps) ON 4 OFF ON OFF ON OFF AL2 (yellow) Flashes (19,200bps) ON 5 OFF ON OFF ON OFF AL3 Flashes (38,400bps) - OFF ON OFF ON OFF AL4 - - OFF ON OFF ON OFF 6 TM4 Series Status Indicator Initial power ON 1 Control output Auto-tuning 2 PWR (green) 3 ON ON ON CH1 (red) Flashes (2,400bps) ON Flash CH2 (red) Flashes (4,800bps) ON Flash CH3 (red) Flashes (9,600bps) ON Flash CH4 (red) Flashes (19,200bps) ON Flash - Flashes (38,400bps) - - Autotuning 2 Copyright Reserved Autonics Co., Ltd. 21

22 1 Product Introduction 1. When power is supplied initially, the set communication speed LED flashes for 5 sec. 2. The auto-tuning CH LED flashes for 1 sec in turn. 3. The PWR LED flashes during communication for 1 sec in turn. 4. Turns ON when CH1 control method is heating & cooling control and cooling output occurs. (disable AL1 setting) 5. Turns ON when CH2 control method is heating & cooling control and cooling output occurs. (disable AL2 setting) Communication address setting switch (SW1): Set the communication address. Communication address group switch (SW2): When setting the communication address over 16, select +16. Lock switch: Used for fixing modules at top and bottom. Rail Lock: Used for installing at DIN rail or using bolts. END cover: Remove it when connecting each module to connect an expansion connector. 22 Copyright Reserved Autonics Co., Ltd.

23 1 Product Introduction Other parts Copyright Reserved Autonics Co., Ltd. 23

24 1 Product Introduction 24 Copyright Reserved Autonics Co., Ltd.

25 2 Specifications 2 Specifications Series TM2 TM4 Number of channels 2 channels (insulated each channel dielectric strength 1,000VAC) 4 channels (insulated each channel dielectric strength 1,000VAC) Power supply Allowable voltage range Power consumption Display method Input type Sampling period Thermocouple 24VDCᜡ 90 to 110% of rated voltage Max. 5W (for max. load) None- parameter setting and monitoring is available at external devices (PC, PLC, etc.) K(CA), J(IC), E(CR), T(CC), B(PR), R(PR), S(PR), N(NN), C(TT), G, (TT), L(IC), U(CC), Platinel II RTD DPt100Ω, JPt100Ω (permissible line resistance max. 5Ω) 50 ms (2 channel simultaneous sampling) 100 ms (4 channel simultaneous sampling) Meatured accuracy Influence of temp. 2 Control Output Control type Option output Option input Hysteresis Thermocouple 1 RTD (PV ±0.5% or ±1, select the higher one) ±1-digit max. CT input ±5% F.S. ±1-digit max. - Current output ±1.5% F.S. ±1-digit max. - Thermocouple RTD Relay (PV ±0.5% or ±2, select the highter one) ±1-digit max. (Thermocouple input max is within ±5 ) Thermocouple B, R, S, C, G, L, U: (PV ±0.5% or ±5, select the highter one) ±1-digit max. 250VACᜠ 3A 1a SSR Max. 12VDCᜡ ±3V 30mA Max. 22VDCᜡ ±3V 30mA Current Heating, Cooling Heating & Cooling Selectable DC 4-20mA or DC 0-20mA (load resistance max. 500Ω) ON/OFF control, P, PI, PD, PID control Alarm 250VACᜠ 3A 1a - Communication CT input Digital input RS485 communication output (Modbus RTU method) A (primary current measurement range) CT ratio: 1/1000 Contact input: ON max. 1kΩ, OFF min. 100kΩ Solid-state input: ON residual voltage max. 1.5VDCᜡ, OFF leakage current max. 0.1mA Outflow current: Approx. 0.5mA per input 1 to 100 / (0.1 to / ) variable Proportional band (P) 0.1 to / Copyright Reserved Autonics Co., Ltd. 25

26 2 Specifications Series TM2 TM4 Integral time (I) 0 to 9999 sec Derivative time (D) Control period 0 to 9999 sec Manual reset 0.0 to 100.0% Relay life cycle Mechanical Electrical Insulation resistance Insulation type Dielectric strength Vibration 0.1 to sec (only relay and, SSR drive output type) Min. 10,000,000 operations Min. 100,000 operations (250VAC 3 A resistance load) 100 MΩ (at 500VDC megger) Double insulation or reinforced insulation (mark:, dielectric strength between measurement part and power part: 1kV) 1,000VAC 50/60Hz for 1 min (between input terminals and power terminals) 0.75mm amplitude at frequency of 5 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours Noise resistance ±0.5kV the square wave noise (pulse width: 1 μs ) by the noise simulator Environment Accessories Approval Weight 3 Ambient temperature -10 to 50, storage: -20 to 60 Ambient humidity Basic module Expansion module 35 to 85%RH, storage: 35 to 85%RH Expansion connector: 1, Power/Comm. connector: 1 (only for basic module) Approx. 217g (Approx. 152g) Approx. 208g (Approx. 143g) Approx. 239g (Approx. 174g) Approx. 231g (Approx. 166g) 1. In case of thermocouple K, J, E, T, N, it is below -100 and L, U, Platinel II, it is below ±2 ±1-digit. In case of thermocouple B, display accuracy cannot be ensured under 400. In case of thermocouple R, S, it is below 200 and C, G, it is max. 3 ±1-digit. 2. Applied when it is for out of room temperature (23±5 ) range. 3. The weight includes packaging. The weight in parenthesis is for unit only. Environment resistance is rated at no freezing or condensation. 26 Copyright Reserved Autonics Co., Ltd.

27 3 Dimensions 3 Dimensions (unit: mm) Expansion modules do not have a power supply/communications connection terminal at the bottom. 3.1 Installation Connector connection Expansion modules do not have a power supply/communications connection terminal. Copyright Reserved Autonics Co., Ltd. 27

28 3 Dimensions Module connection TM Series allows simulataneous monitoring for multi channel I/O with connecting Multiple modules using module expansion connectors. Connect expansion modules to a basic module. Basic module can be placed in any position among multiple module sets. Remove the cover. 1st Remove each module's END covers. (do not remove at the ends of END covers) 2nd Connect expansion connectors between modules. 3rd Push each modules. (max. 30 units) 4th Push the lock switch to lock direction. Supply adequate power for power input specifications and overall capacity. (Max. power when connecting 31 modules: 31 units 5W=155W) Install the units vertically. Use end plates (sold separately, not available from Autonics) to fix firmly. 28 Copyright Reserved Autonics Co., Ltd.

29 3 Dimensions Mounting with bolts 1st Pull each rail lock to up and down. 2nd Insert bolts to fix it on rail lock. (fixing torque is 0.5 to 0.9 N m) Mounting on DIN rail (1) Installation/Removal method of a single module Installing 1st Hang the top rail lock to DIN rail. 2nd Push and press the module to down direction. Copyright Reserved Autonics Co., Ltd. 29

30 3 Dimensions Removing 1st Press the module to down direction. 2nd Pull the module body forward. (2) Installation/Removal method of multiple modules Installing 1st Pull each rail lock switch up and down. 2nd Mount the module body to the DIN rail and then push the rail lock in. Removing 1st Pull each rail lock switch up and down. 2nd Remove the body from the DIN rail. 30 Copyright Reserved Autonics Co., Ltd.

31 4 Connections and Insulation Block Diagram 4 Connections and Insulation Block Diagram 4.1 TM2 Series Relay AL3/AL4 OUT are available only for TM2-42 models. Power/Comm. connection terminal [Only for basic module: TM - B] Copyright Reserved Autonics Co., Ltd. 31

32 4 Connections and Insulation Block Diagram 4.2 TM4 Series Power/Comm. connection terminal [Only for basic module: TM - B] Pay attention to the connection direction when wiring the power supply/communications connection terminal. It is recommended to use lines with AWG28 to 14 when connecting the sensor or compensation wire. It is recommended to use lines thicker than AWG24 for SSR drive output. It is recommended to use lines with AWG26 to 12 for relay output. 32 Copyright Reserved Autonics Co., Ltd.

33 4 Connections and Insulation Block Diagram 4.3 Wiring precautions Mixing up the input terminals with output terminals and vice versa can lead to product damage. Use only sensors supported by the product. Make sure to connect rated SSRs or loads to the output terminals. Make sure to connect the communication cable with correct communication terminals (A, B). Make sure to observe correct polarity of power source terminals. (+ and -). Use crimp terminals of size specified below. a c b Terminal number a b c 1 to 12 10mm Max. 1.7mm Max. 3.7mm 13 to 22 10mm Max. 2.1mm Max. 4.2mm Sensor connection (1) Compensation wire connection For thermocouple sensors, use compenstion wire of the same specification as input sensors. Using an extension wire of different specification and/or material will increase inaccuracy of temperature sensing. It is recommended to choose high performance compensation wire for more reliable sensing. (2) Measurement error Do not mix up the direction of the input sensor connector. Carefully adjust both load and sensor positions. Make sure the sensor is securely attached to the input connector. (3) Wiring with AC power lines Do not put the sensor lines in close proximity of the AC power lines. Make sure the sensor is completely inserted in the connector using a crimped terminal. Fix the sensor to the connecter properly for accurate measurement. Copyright Reserved Autonics Co., Ltd. 33

34 4 Connections and Insulation Block Diagram Power supply connection Use power line with AWG26 to 12. Calculate the total power consumption first and then connect a power supply system of appropriate capacity Communication line wiring Do not tie the communications line together with the AC power line. Use twisted pair cables for the communications line only. Do not allow the communication line to exceed 800m in length. For further details, please refer to 6.5 Communications. 34 Copyright Reserved Autonics Co., Ltd.

35 4 Connections and Insulation Block Diagram Module connection (1) Basic module positioning The basic module can be mounted anywhere in the connected group. It works regardless of communication address. Copyright Reserved Autonics Co., Ltd. 35

36 4 Connections and Insulation Block Diagram (2) Module Expansion When using the bottom power supply/communication connection terminal (Power/Comm. connection terminal), up to 31 modules can be connected at the same time. Maximum required power = 31 X 5 W = 155 W When connecting several module sets (31 modules or less), each module set requires separate power supply. 36 Copyright Reserved Autonics Co., Ltd.

37 5 Preparation and Startup 5 Preparation and Startup 5.1 General process Before operating TM Series for the first time, do the following: 1st Connect all external devices, sensor and load to the TM Series. 2nd Set parameter values through external connecting devices (PC loader program, GP etc.). 3rd Download the parameters to TM Series. 4th Proceed with auto-tuning or set control variables, and then start control. For using comprehensive devicem management program DAQMaster, parameters are automatically downloaded at the time when they are changed. 5.2 Setup values when power ON Setting category Auto/Manual RUN/STOP PID/ONOFF MV Factory default Auto RUN PID Previous setting value Auto Manual RUN STOP PID ONOFF Power ON setting value Auto Manual RUN STOP Maintains preset value Maintains preset value 0.0 Preset MV Maintains preset value 0.0 Stop MV Maintains preset value 0.0 Sensor Error MV Maintains preset value Copyright Reserved Autonics Co., Ltd. 37

38 5 Preparation and Startup 5.3 Temperature control examples Single module (1) TM4-N2RB model (relay output) 1. Using SCM-US enables only setting parameter. To monitor and control temperature requires the additional 24VDC power supply. Do not connect SCM-US and RS485 communications cables at the bottom at the same time. 38 Copyright Reserved Autonics Co., Ltd.

39 5 Preparation and Startup (2) TM4-N2SB model (SSR drive output) 1. Using SCM-US enables only setting parameter. To monitor and control temperature requires the additional 24VDC power supply. Do not connect SCM-US and RS485 communications cables at the bottom at the same time. Use an isolated type SSR. Copyright Reserved Autonics Co., Ltd. 39

40 5 Preparation and Startup Multiple modules 40 Copyright Reserved Autonics Co., Ltd.

41 6 Parameter Settings and Functions 6 Parameter Settings and Functions 6.1 Input Input type and temperature range Input Type Thermocouples K(CA) J(IC) E(CR) T(CC) No. Decimal point Indicator Temperature range ( ) Temperature range ( ) 0 1 K(CA).H -200 to to K(CA).L to to J(IC).H -200 to to J(IC).L to to E(CR).H -200 to to E(CR).L to to T(CC).H -200 to to T(CC).L to to B(PR) 8 1 B(PR) 0 to to 3272 R(PR) 9 1 R(PR) 0 to to 3182 S(PR) 10 1 S(PR) 0 to to 3182 N(NN) 11 1 N(NN) -200 to to 2372 Platinum Resistance Temperature Detector (RTD) C(TT) C(TT) 0 to to 4172 G(TT) G(TT) 0 to to 4172 L(IC) U(CC) 14 1 L(IC).H -200 to to L(IC).L to to U(CC).H -200 to to U(CC).L to to Platinel II 18 1 PLII 0 to to 2552 JPt100 Ω DPt100 Ω 19 1 JPt100.H -200 to to JPt100.L to to DPt100.H -200 to to DPt100. L to to C(TT): Same as existing W5(TT) type temperature sensor/ 2. G(TT) : Same as existing W(TT) type temperature sensor. Temperature sensors convert subject temperature to electrical signals for the temperature controller, allowing it to control output. SV (setting value) can only be set within the input range. Copyright Reserved Autonics Co., Ltd. 41

42 6 Parameter Settings and Functions Input type This product supports multiple input types, making it possible for the user to choose from thermocouples, resistors, and analog voltage/current. Different sensors can be designated to each channel. CH1 input type = KCA.H, CH2 input type = JIC.H Setting group Parameter Setting range Initial Setting Input Type Refer to Input type and temperature range Factory default K(CA).H - Unit When changing input type settings, the high-limit and low-limit values of SV are automatically changed to max/min values of operational temperature range of the modified input type. You must reset these values. (SV, Multi SV No, SV-0 to SV-3 and input correction are initialized.) However, measurement units remain the same. If the measured value is out of the input range, external device displays HHHH (high-limit), LLLL (low-limit) and displays OPEN when the sensor is not connected Input temperature sensor unit When selecting the temperature sensor input options, you can set the desired units of operation temperature/display temperature. Setting group Parameter Setting range Factory default Initial Setting Unit, - Unit When modifying the temperature units, setting values of the related parameters remain the same as the existing values, and SV, Multi SV No., SV-0 to SV-3, SV high-limit/low-limit, and input correction will be initialized. 42 Copyright Reserved Autonics Co., Ltd.

43 6 Parameter Settings and Functions Input correction This feature is used to compensate for input correction produced by thermocouples, RTDs, or analog input devices, but NOT by the controller itself. The input correction adjustments function is mainly used when the sensor cannot be attached directly to control object. It is also used to compensate for temperature variance between the sensor's installation point and the actual measuring point. Setting group Parameter Setting range Initial Setting Input Bias -999 to 999 (H) to (L) Factory default Unit 0 Digit If the controller displays 78 when the actual temperature is 80, set the input correction to 2 in order to adjust the controller's display temperature to 80. Make sure that an accurate temperature variance measurement is taken before setting values of Input Correction. An inaccurate initial measurement can lead to greater variance. Many of today's temperature sensors are graded by their sensitivity. Since higher accuracy usually comes at a higher cost, most people tend to choose sensors with medium sensitivity. Measuring each sensor's sensitivity correction and using the Input Correction feature for correction can ensure higher accuracy in temperature reading Input digital filter It is not possible to perform high accuracy control if the PV (present value) fluctuates because of noise elements, disturbance, or instabilities in the input signal. Using the Input Digital Filter function can stabilize PV to realize more reliable control. Setting group Parameter Setting range Factory default Initial Setting Digital Filter 0.1 to Sec. Unit When the Input Digital Filter is set to 0.4 seconds, the digital filter is applied according to a sampling value collected over 0.4 seconds (400ms). When the Input Digital Filter is used, PV (present value) can vary from the actual input value. Copyright Reserved Autonics Co., Ltd. 43

44 6 Parameter Settings and Functions SV high/low-limit value You can limit the SV (setting value) range within the temperature range of the sensor or analog input type (refer to Input type and temperature range) in order to prevent the system from controlling with improper SV. Factory Setting group Parameter Setting range default SV High-limit 1350 Initial Setting Refer to the below. SV Low-limit -200 SV low-limit value: Min. value of input sensor range to SV high-limit - 1 digit SV high-limit value: SV low-limit + 1 digit to max. value of input sensor range Unit / Attempts to set the limits outside the min/max input range, or analog's high/low-limits, are not accepted. Instead, the previous settings are retained. SV (setting value) can only be set within the SV low-limit and SV high-limit. SV low-limit cannot exceed SV high-limit. Changing the input sensors automatically changes the SV high/low-limit settings to max/min values of the changed input sensor input. The user is required to reset related settings. 44 Copyright Reserved Autonics Co., Ltd.

45 6 Parameter Settings and Functions 6.2 Control output Control output operation mode Control output modes for general temperature control include heating, cooling, and heating and cooling. Heating control and cooling control are mutually opposing operations with inverse outputs. The PID time constant varies based on the controlled objects during PID control. Setting group Parameter Setting range Initial Setting Operating Type HEATING, COOLING HEATING & COOLING Factory default HEATING - Unit (1) Heating control Heating control mode: the output will be provided in order to supply power to the load (heater) if PV (present value) falls below SV (setting value). (2) Cooling control Cooling control mode: the output will be provided in order to supply power to the load (cooler) if PV (present value) rises above SV (setting value). Copyright Reserved Autonics Co., Ltd. 45

46 6 Parameter Settings and Functions (3) Heating and cooling control Heating and cooling control mode: heating and cooling with a single temperature controller when it is difficult to control subject temperature with only heating or cooling. Heating and cooling control mode controls the object using different PID time constants for each heating and cooling. It is also possible to set heating and cooling control in both PID control or ON/OFF control mode. Heating/cooling output can be selected among Relay output, SSR drive voltage output and current output depending on model types choosen according to your application environment. (Note that only standard SSR control is available for SSR drive output in OUT2.) For heating/cooling control, each output for heating and cooling is automatically allocated as described in the following table. Series TM4 TM2 Heating Cooling control control Remarks CH1 OUT CH2 OUT Heating output: Selectable control output by model CH3 OUT CH4 OUT Cooling output: Selectable control output by model CH1 OUT AL1 OUT Heating output: Selectable control output by model CH2 OUT AL2 OUT Cooling output: Relay output fixed For TM2 Series, heating output can be selected by models from relay output, SSR drive output and current output. Cooling output is fixed to relay output. 46 Copyright Reserved Autonics Co., Ltd.

47 6 Parameter Settings and Functions Deadband/Overlap band In heating and cooling control, it is possible to designate a deadband between heating and cooling control bands based on SV (setting value). A deadband forms around the SV when DB is set to a positive value. No control occurs in the deadband area. Therefore, heating and cooling MVs become 0.0% in the formed deadband. An overlap band (simultaneous application of heating and cooling MVs) forms around the SV when DB is set to a negative value. Setting group Control Operation Preceding condition PID-PID PID-ON/OFF ON/OFF-PID ON/OFF-ON/OFF Parameter Dead_Overlap band Setting range -P BAND to +P BAND to 0 to 999 (H) to 0 to (L) Set deadband to 0 when a deadband or an overlap band is not used. Factory default 0 Unit Digit When proportional bands are different, the smaller one takes precedence. Input sensor (H, L) setting determines the use of a decimal point. Copyright Reserved Autonics Co., Ltd. 47

48 6 Parameter Settings and Functions (1) Using Deadband 48 Copyright Reserved Autonics Co., Ltd.

49 6 Parameter Settings and Functions (2) Using Overlap band Copyright Reserved Autonics Co., Ltd. 49

50 6 Parameter Settings and Functions (3) Using neither Deadband nor Overlap Band 50 Copyright Reserved Autonics Co., Ltd.

51 6 Parameter Settings and Functions MV high/low-limit value MV high/low-limit values for control output can be configured to the actual MV, provided the temperature controller's MV calculation exceeds the limits. During heating and cooling control, cooling MV carries a "-" prefix. Therefore, the high-limit is expressed as a + value on the heating side and the lower limit as a - value on the cooling side. Setting group Control Operation Preceding condition Heating Cooling Heating and Cooling Parameter Setting range MV Low-limit 0.0 to MV high-limit Factory default MV High-limit MV low-limit to MV Low-limit to MV High-limit 0.0 to Unit % % Same MV high/low-limit value will be applied during Auto-tuning. MV high/low-limit values are not applied to manual control, MV upon control stop, MV upon a sensor error, and initial manual control MV. MV high/low-limit value configuration is not available for ON/OFF control in standard control mode (heating or cooling control). Copyright Reserved Autonics Co., Ltd. 51

52 6 Parameter Settings and Functions Ramp function Ramp is a feature used to configure the changed temperature per unit time toward SV (setting value). The feature limits change rate of SV and thereby restricts sudden temperature changes (increase and decrease) in the control subject. Ramp is commonly used in applications where rapid temperature changes (increase and decrease) could impact negatively on the control subject. SV determines the control of the control subject temperature. The SV changes based on the configured changed temperature per unit time (hereinafter referred to as RAMP SV). Ramp Up change rate and Ramp Down change rate can be set independently. Setting group Parameter Setting range Control Operation Ramp_Up/Down Change Rate 0 (OFF) to Factory default Ramp Time Unit SEC, MIN, HOUR MIN - Unit / / Digit For ceramic or pottery furnaces, rapid heating may break the furnace subject. Apply Ramp Up Change Rate to control the temperature. Activating the ramp feature when the ramp is not in operation limits the rate of SV (setting value) change based on PV (present value). Changing SV or ramp parameters when the ramp is in operation limits the rate of SV change based on SV at the point of the change. Alarm activation with the ramp in operation depends on the final SV. Setting the rate of ramp change to 0 deactivates the ramp feature. (1) Ramp status by modes Operation status RAMP rate Ramp function All modes. When 0 Inactive OPEN, HHHH, LLLL, Auto-tuning, Auto Manual, RUN STOP OPEN, HHHH, LLLL, after Auto-tuning, PV = SV Power On, SV change, switch from STOP to RUN, switch from Manual to Auto, Ramp Rate or Ramp time unit change Irrespective of conditions. Irrespective of conditions. When not 0 Inactive Inactive Active 52 Copyright Reserved Autonics Co., Ltd.

53 6 Parameter Settings and Functions Example Ramp graph Copyright Reserved Autonics Co., Ltd. 53

54 6 Parameter Settings and Functions Auto/Manual control Auto control: This mode implements control over MV, which is calculated under PID control and based on SV as the target. Manual control: This mode implements control with user-defined MV. Setting group Parameter Setting range Factory default Monitoring Auto-Manual Control AUTO, MANUAL AUTO - Can be used by setting digital input terminal (DI1, DI2) to STOP function. Unit Auto/manual control switching is not allowed in ON/OFF control mode. When the unit is powered on following a power interruption or shutdown, auto or manual control will be maintained. When in operation, AT (Auto-tuning) can be switched to manual control. When in Stop mode, manual control can be activated. If SBA (Sensor Break Alarm) occurs during standard control, the sensor error MV is applied. In this state, switching to manual mode is possible and manual control MV settings can also be modified. When the control unit is in operation, it is possible to switch to manual or auto control mode. Priority: Manual control > Stop > Open (sensor break) Manual control baseline MV When switching from auto to manual control you can set the initial MV. AUTO-MV: When switching modes use auto control MV as the initial manual control. PRESET-MV: Apply preset MV as the initial MV. Setting group Preceding condition Parameter Control Setting PID Initial Manual MV Setting range AUTO-MV: PRESET-MV: Factory default AUTO-MV: - Unit Reverting to power, the control starts with the MV of the power off. 54 Copyright Reserved Autonics Co., Ltd.

55 6 Parameter Settings and Functions Manual control initial MV If the baseline MV for manual control is configured to PRESET-MV, you can set the initial MV for manual control. Setting group Control Setting Preceding condition Parameter Setting range Heating, Cooling, PID Heating & Cooling, PID Preset Manual MV 0.0 to (Cool) to (Heat) Factory default 0.0 Unit % When in heating and cooling control, a setting between 0.1 and applies heating MV, and a setting between 0.1 and applies cooling MV Control output If the control output type is a current or SSR drive output model, control output is supported at the same time, so the user can choose a suitable output type. Setting group Parameter Setting range Initial Setting Output(SSR_Curr) Type Factory default SSR, CURRENT SSR - Unit The relevant parameter will be activated only if the model is TM2- C (current or SSR drive output type) Current output range If the control output is set to current output, you can select high and low-limit range for the current output as either 4-20mA or 0-20mA. Setting group Parameter Setting range Factory default Initial Setting Current Output Range 0-20, ma Unit If the model is TM2- C (current or SSR drive output type), the relevant parameter will be activated only if the control output is set to current. Copyright Reserved Autonics Co., Ltd. 55

56 6 Parameter Settings and Functions 6.3 Temperature control Temperature control method You can choose the type of temperature control method. Setting group Preceding condition Parameter Setting range Factory default Unit Heating, Cooling PID, ONOFF PID - Initial Setting Heating and Cooling Control Method PID-PID PID-ONOFF ONOFF-PID ONOFF-ONOFF PID-PID ON/OFF control Controls the temperature by comparing PV(present value) with SV(setting value) and turning power to the load on or off Hysteresis An ON/OFF control feature is used to define the control output ON/OFF points. ON_Hysteresis sets the output on point and OFF_Offset sets the off point. Setting hysteresis too low can result in hunting induced by disturbance (noise, chattering, etc.). To minimize hunting, set ON_Hysteresis and OFF_Offset values according to the heater or cooler's capacity and thermal characteristics, control subject and sensor response characteristics, installation conditions, and other defining factors. Setting group Control Operation Preceding condition Heating & Cooling Heating Cooling Parameter Heating_ON Hysteresis Heating_OFF Offset Cooling_ON Hysteresis Cooling_OFF Offset Setting range 1 to 100(H) 0.1 to 100.0(L) 0 to 100(H) 0.0 to 100.0(L) 1 to 100(H) 0.1 to 100.0(L) 0 to 100(H) 0.0 to 100.0(L) Factory default Unit Digit 56 Copyright Reserved Autonics Co., Ltd.

57 6 Parameter Settings and Functions PID control PID control is a combination of proportional (P), integral (I), and derivative (D) controls and offers superb control over control subjects, even with a delay time. Proportional control (P) implements smooth, hunting-free control; integral control (I) automatically corrects offsets; and derivative control (D) speeds up the response to disturbance. Through these actions, PID control realizes ideal temperature control. How to apply PID control Proportional (P) control: Set both integral and derivative times to 0 after PID control is selected. Proportional-Integral (PI) control: Set the derivative time to 0 after PID control is selected. Proportional-Derivative (PD) control: Set the integral time to 0 after PID control is selected. When using the multi-sv function, the same PID time constant will be applied to SV0 to SV Proportional band When PV (present value) is within the proportional band (P), the ON/OFF ratio needs to be adjusted during the proportional period (T). The defined proportional control (time proportional control) section is referred to as the proportional band. Setting group Control Operation Integral time Preceding Setting Parameter condition range Heating, PID Heating_Proportional Band 0.1 to Cooling, PID Cooling_Proportional Band Factory default Unit 10.0 / MVs from integral and proportional operation become the same when deviation is consistent. The time taken for the two MVs to match is called the integral time. Setting group Control Operation Preceding condition Heating, PID Cooling, PID Parameter Heating_Integral Time Cooling_Integral Time Setting range Factory default Unit 0 to Sec. Integral control is not conducted if the integral time is set to 0. Setting the integral time too short can intensify Correction Movements and cause hunting. Copyright Reserved Autonics Co., Ltd. 57

58 6 Parameter Settings and Functions Derivative time In accordance with the deviation of the ramp, the time taken for the MV gained from derivative operation to reach the MV gained from proportional control is called the derivative time. Setting group Control Operation Preceding Setting Parameter condition range Heating, PID Heating_ Derivation Time 0 to Cooling, PID Cooling_ Derivation Time 9999 Factory default Unit 0 Sec. Derivative control is not conducted if the derivative time is set to Control period If relay or SSR is used to send out MV under proportional control, the output is on for a fixed amount of time (within the control period, as a percentage of the MV) and then remains off. The preset period when output ON/OFF takes place is called the proportional control period. Control using SSR drive voltage output has a faster response than that of relay output. Therefore, by configuring a shorter control period, more responsive temperature control is achieved. Setting group Initial Setting Preceding Setting Parameter condition range Heating, PID Heating_ Control Time 0.1 to Cooling, PID Cooling_ Control Time Factory default 20.0 (RY) 2.0 (SSR) Unit Sec. If using heating and cooling control, configure each control period separately for heating and cooling. 58 Copyright Reserved Autonics Co., Ltd.

59 6 Parameter Settings and Functions Offset correction/manual reset When only proportional control (P, PD control) is used, the control subject's thermal capacity and heater capacity affect the heating and cooling time. This means stable control will still experience some deviation called offset. Offset can be corrected using manual reset. Preceding Setting Factory Setting group Parameter Unit condition range default Control Operation PID Manual Reset 0.0 to % Manual reset adjustment based on control results Under stable control conditions, set the offset to 50% if PV and SV are identical, to over 50.0% if PV is lower than SV, and below 50.0% if PV is higher than SV. The offset correction feature can only be used when proportional control is in effect. Setting the integral value to 0 makes the manual reset parameter visible. The user cannot configure the manual reset setting during heating and cooling control. Instead, the setting is automatically set to 0% for both heating and cooling. Applicable only when integral time is set to 0 (under P control or PD control only). Switching from heating and cooling control to standard control (P, PD control) automatically configures the reset setting to 50%. Copyright Reserved Autonics Co., Ltd. 59

60 6 Parameter Settings and Functions Auto-tuning In PID control, auto-tuning processes the control subject's thermal characteristics and thermal response rate, and then determines the necessary PID time constant. Application of the PID time constant realizes fast response and high precision temperature control Auto-tuning ON/OFF Auto-tuning automatically stores PID time constants upon termination. These PID time constants can then be modified by the user to suit their usage environment. When performing auto-tuning, the output LED of the pertinent channel flashes at 1 second intervals. Once auto-tuning is complete, the output LED automatically goes off, and the parameter value returns from ON to OFF. Setting group Control Operation Preceding condition PID Parameter Auto-Tuning Execute Setting range Factory default OFF, ON OFF - Unit If manual control is selected during auto-tuning, auto-tuning operation will be closed. If sensor break error occurrs during auto-tuning, the sensor is automatically closed and the previous PID time constant kept. Auto-tuning continues to run even if the temperature reading exceeds or falls below the input range. When auto-tuning is in progress, parameters can only be referenced and not altered. When auto-tuning is in progress and digital input(di-1,di-2) feature is run/stop or auto/manual, auto-tuning will be automatically ended, if concerned DI is inputted or sensor break error occurs. Auto-tuning is not available in manual control. 60 Copyright Reserved Autonics Co., Ltd.

61 6 Parameter Settings and Functions Auto-tuning mode Auto-tuning is available in Tun1 MODE (SV) or Tun2 MODE (70% of SV), depending on the baseline value used. Tun1 Mode [TUN1]: Auto-tunes and calculates a PID time constant based on SV. Tun2 Mode [TUN2]: Auto-tunes and calculates a PID time constant based on 70% of SV. Setting group Initial Setting Preceding condition PID Parameter Auto-Tuning Mode Setting range TUN1 TUN 2 Factory default TUN 1 - Unit In cooling control mode, TUN2 Mode calculates 70% based at 0. E.g.) If SV is -100, executes TUN2 at -70. Copyright Reserved Autonics Co., Ltd. 61

62 6 Parameter Settings and Functions 6.4 Alarm output Alarm output is a relay output that activates irrespective of control output. Alarm output works when the temperature of the controlled subject exceeds or falls below the preset temperature range. Alarm temperature setting values consist of absolute temperatures or offset temperatures, depending on the alarm output mode. Alarm output function is only for TM2 Series Alarm output target channel Users can set channels in which alarm output (2 or 4) will be activated. Setting group Parameter Setting range Factory default Unit Alarm Setting Alarm Target Ch CH1, CH2, CH1 and CH2, CH1 or CH2 Alarm 1, 3: CH1 Alarm 2, 4: CH2 - In case of heating/cooling control, Alarm 1 and Alarm 2 are used as a cooling control output; therefore, they cannot be used as an alarm output. 62 Copyright Reserved Autonics Co., Ltd.

63 6 Parameter Settings and Functions Alarm output operating mode Select the desired alarm output mode. Mode Alarm Output Description (Factory default) OFF AL-1 AL-2 AL-3 AL-4 AL-5 AL-6 No alarm output LBA On if loop break is detected. Loop break alarm Deviation high-limit alarm (+F.S.) If PV/SV deviation occurs higher than set value of deviation temperature, alarm output will be ON. High limit deviation temperature can be set in AL1.H/AL2.H/AL3.H/AL4.H. Deviation low-limit alarm ( +F.S.) If PV/SV deviation occurs lower than set value of deviation temperature, alarm output will be ON. Low-limit deviation can be set in AL1.H/AL2.H/AL3.H/AL4.H. Deviation high/low-limit alarm ( +F.S.) If PV/SV deviation occurs higher than high-limit deviation or lower than lowlimit deviation, alarm output will be ON. High-limit deviation can be set in AL1.H/AL2.H/AL3.H/AL4.H. Low-limit deviation can be set in AL1.H/AL2.H/AL3.H/AL4.H. Deviation high/low-limit reverse alarm If PV/SV deviation occurs higher than low-limit deviation or lower than highlimit deviation, alarm output will be ON High-limit deviation can be set in AL1.H/AL2.H/AL3.H/AL4.H. Low-limit deviation can be set in AL1.H/AL2.H/AL3.H/AL4.H. Absolute value high-limit alarm If PV is higher than the absolute value of temperature, alarm output will be ON. Alarm absolute value can be set in AL1.H/AL2.H/AL3.H/AL4.H. Absolute value low-limit alarm If PV is lower than the absolute value of temperature, alarm output will be ON. Alarm absolute value can be set in AL1.L/AL2.L/AL3.L/AL4.L. SBA On if sensor break is detected. Sensor break alarm HBA On if current transformer (CT) detects heater break. Heater burnout alarm Setting group Parameter Setting range Factory default Unit Alarm Setting Alarm Mode Refer to the above table. Alarm 1, 3: AL-1 Alarm 2, 4: AL-2 - Copyright Reserved Autonics Co., Ltd. 63

64 6 Parameter Settings and Functions Alarm output option Select the desired alarm output option mode. Setting Mode Description AL-A Standard alarm If it is an alarm condition, alarm output is ON. Unless an alarm condition, alarm output is OFF. 1 If it is an alarm condition, alarm output is ON. Before reset the AL-B Alarm latch alarm, an ON condition is latched. (Holding the alarm output) AL-C AL-D AL-E AL-F Standby sequence 1 2 Alarm latch and standby sequence 1 Standby sequence 2 Alarm latch and standby sequence 2 When power is supplied and it is an alarm condition, alarm output does not act. From the second alarm conditions, standard alarm acts. When power is supplied and it is an alarm condition, alarm output does not act. From the second alarm conditions, alarm latch acts. When Standby sequence 3 and it is an alarm condition, alarm output does not act. After deactivate the alarm condition, standard alarm acts. When Standby sequence 3 is repeated and it is an alarm condition, alarm output does not act. After deactivate the alarm condition, alarm latch acts. 1. Alarm Latch: Deactivating Alarm Output in Alarm Latch mode: Turn off the power or send alarm reset signal. 2. Standby sequence: This option is applied only if PV is in alarm output ON conditions when power is supplied. If not, alarm output will be provided from the first alarm condition same as other alarm operations. 3. Conditions of repeated Standby sequence: Power ON, Changing SV, Related Alarm(operation mode, option, setting value), Changing Parameter, Changing STOP mode to RUN mode. Setting group Parameter Setting range Factory default Unit Alarm Setting Alarm Type Refer to the above table. AL-A - You can set alarm output (Alarm 1 Type to Alarm 4 Type) individually. If alarm output mode has been selected as LBA, SBA or HBA, AL-C, AL-D modes are not available. 64 Copyright Reserved Autonics Co., Ltd.

65 6 Parameter Settings and Functions Example of SV: 100, alarm output operation mode: AL-3(Deviation high/low-limit alarm), alarm option: AL-E(Standby sequence 2), (deviation high/low-limit temperature: 10, alarm output hysteresis: 5 ) When first alarm condition occurs, alarm output does not operate. From the sencond alarm condition, alarm output operates Alarm SV You can set alarm output activation values. According to the selected alarm output mode, configuration parameters (AL.H/AL.L) will be activated for each setting. Setting group Alarm Setting Parameter Alarm High_Ch Alarm Low_Ch Setting range Deviation alarm: F.S. to F.S. Absolute value alarm: Within the temperature range of input type Factory default Unit 1550 / Changing the alarm output mode or options resets the settings to the highest or lowest values that will not trigger output in the new mode. Copyright Reserved Autonics Co., Ltd. 65

66 6 Parameter Settings and Functions Alarm output hysteresis H shown in the image from Alarm output operating mode reresents the alarm output hysteresis. It is used to set an interval between alarm output ON/OFF periods. If PV is over or below alarm output SV, output turns ON and it sets OFF time by hysteresis settings. When input value is changed near SV, alarm output is often. Set hysteresis and it can be prevent from often alarm output. Can be set individually by alarm output (Alarm 1 Type to Alarm 2 Type). Setting group Parameter Setting range Alarm Setting Alarm Hysteresis_Ch 1 to 100 (H), 0.1 to (L) Factory default Unit 1 Digit Alarm output hysteresis applies to heater burnout alarm (HBA) in the same manner. This parameter does not appear if Loop Break Alarm (LBA) or Sensor Break Alarm (SBA) is selected Alarm output method Relay type can be set at alarm output. N.O. (Normally Open) stays open when normal and closes in the event of an alarm. N.C. (Normally Closed) stays closed when normal and opens in the event of an alarm. Setting group Parameter Setting range Factory default Alarm Setting Alarm NO/NC NO, NC NO - Unit Front indicators Change Alarm occurs Alarm output Indicator N.O. OFF Open OFF ON Close ON N.C. OFF Close OFF ON Open ON 66 Copyright Reserved Autonics Co., Ltd.

67 6 Parameter Settings and Functions Alarm output delay Alarm output delay can be set to prevent false alarms caused by erroneous input signals resulting from disturbances or noise. With a preset delay time, alarm output does not turn on for the preset duration. Instead, the concerned alarm indicator on the front will flash in 0.5-second intervals. Alarm ON delay time: Stands by for the preset duration upon an alarm event, checks the alarm trigger conditions, and turns on the alarm output if the conditions are still present. Alarm OFF delay time: Stands by for the preset duration following alarm output off, checks the alarm trigger conditions, and turns off the alarm output if the deactivation conditions are still present. Setting group Alarm Setting Parameter Setting range Factory default Unit Alarm ON Delay Time 0 to Sec. Alarm OFF Delay 0 to Sec. Copyright Reserved Autonics Co., Ltd. 67

68 6 Parameter Settings and Functions Loop break alarm(lba) Diagnoses the control loop by monitoring the control subject's temperature changes and sends out alarms if necessary. Heating control: When control output MV is 100% or high limit (MV high limit) and PV is not increased over than LBA detection band (LBA Band) during LBA monitoring time (LBA Time), or when control output MV is 0% or low limit (MV low limit) and PV is not decreased below than LBA detection band (LBA Band) during LBA monitoring time (LBA Time), alarm output turns ON. Cooling control: When control output MV is 0% or low limit (MV low limit) and PV is not increased over than LBA detection band (LBA Band) during LBA monitoring time (LBA Time), or when control output MV is 100% or high limit (MV high limit) and PV is not decreased below than LBA detection band (LBA Band) during LBA monitoring time (LBA Time), alarm output turns ON. Common causes of LBA output ON Sensor error (disconnection, short) External controller error (magnet, auxiliary relay, etc.) External load error (heater, cooler, etc.) Misconnections and disconnections of external network. If it is not as sensor break/hhhh/llll, during auto-tuning/manual control/control STOP/ramp function operation, loop break alarm does not operate. Type Initializing Alarm, changing control output operation mode, setting LBA monitoring time/band as 0 Changing input correction value, set value Changing MV, stopping control, running auto-tuning Occurring sensor break alarm, HHHH, LLLL LBA monitoring time Initialize Alarm output Standard alarm OFF Maintains the present alarm OFF ON Alarm latch OFF Maintains the present alarm Maintains the present alarm ON Set alarm output operation mode (Alarm Mode) as loop break alarm (LBA) and you can use loop break alarm. When executing auto-tuning, LBA detection band (LBA Band) and LBA monitoring time(lba Time) is automatically set based on auto-tuning value. In case of AT (auto-tuning)/manual control/stop control, loop break alarm (LBA) does not operates. When alarm reset is input, it initializes LBA monitoring start time. 68 Copyright Reserved Autonics Co., Ltd.

69 6 Parameter Settings and Functions LBA monitoring time You can set the LBA monitoring time to check changes in the control subject's temperature. Automatically setting with auto-tunning. Regardless of alarm output operation mode (Alarm Mode) (including LBA monitoring time as 0 ), after running auto-tuning, the integration time 2 value is saved automatically. (If SV is out of the range of auto setting, it is set as max. or min. value of auto setting.) Except input type changing, re-running auto-tuning, manual setting of LBA monitoring time, it maintains the present SV. Auto setting range: 0020 to 9999 Setting group Parameter Setting range Factory default Unit Alarm Setting LBA Time Ch1, LBA Time Ch to Sec LBA detection band You can set the minimum value of deviation change to decrease during LBA monitoring time. Automatically setting with auto-tunning. Regardless of alarm output operation mode (Alarm Mode) (including LBA monitoring time as 0 ), after running auto-tuning, the integration time 2 value is saved automatically. Except input type changing, re-running auto-tuning, manual setting of LBA monitoring time, it maintains the present SV. (If SV is out of the range of auto setting, it is set as max. or min. value of auto setting.) Auto setting range Temperature L: to ( / ) Temperature H: 0002 to ( / ) Setting group Parameter Setting range Alarm Setting LBA Band Ch1, LBA Band Ch2 0 to 999 (H) 0.0 to (L) Factory default Unit 2 / Copyright Reserved Autonics Co., Ltd. 69

70 6 Parameter Settings and Functions It checks control loop and outputs alarm by temperature change of the subject. For heating control(cooling control), when control output MV is 100%(0% for cooling control) and PV is not increased over than LBA detection band (LBA Band) during LBA monitoring time (LBA Time), or when control output MV is 0%(100% for cooling control) and PV is not decreased below than LBA detection band (LBA Band) during LBA monitoring time (LBA Time), alarm output turns ON. Start to 1 1 to 2 2 to 3 3 to 4 4 to 6 6 to 7 7 to 8 8 to 9 When control output MV is 100%, PV is increased over than LBA detection band (LBA Band) during LBA monitoring time (LBA Time). The status of changing control output MV (LBA monitoring time is reset.) When control output MV is 0% and PV is not decreased below than LBA detection band (LBA Band) during LBA monitoring time (LBA Time), loop break alarm (LBA) turns ON after LBA monitoring time (LBA Time). Control output MV is 0% and loop break alarm (LBA) turns and maintains ON. The status of changing control output MV (LBA monitoring time is reset.) When control output MV is 100% and PV is not increased over than LBA detection band (LBA Band) during LBA monitoring time (LBA Time), loop break alarm (LBA) turns ON after LBA monitoring time (LBA Time). When control output MV is 100% and PV is increased over than LBA detection band (LBA Band) during LBA monitoring time (LBA Time), loop break alarm (LBA) turns OFF after LBA monitoring time (LBA Time). The status of changing control output MV (LBA monitoring time is reset.) 70 Copyright Reserved Autonics Co., Ltd.

71 6 Parameter Settings and Functions Sensor break alarm You can set the controller to send out an alarm when a sensor is not connected or disconnected during temperature control. Sensor break can be confirmed through an external alarm output contact, such as a buzzer or similar means. Setting alarm output mode (alarm mode) to SBA will activate sensor break alarm. Alarm output option can be set to standard alarm (AL-A) or alarm latch (AL-B) Heater burnout alarm When using a heater to raise the temperature of the control subject, the temperature controller can be set to detect heater disconnection and send out an alarm by monitoring power supply to the heater. Heater disconnection is detected by the controller using a current transformer (CT), which converts the current to the heater to a specific ratio (CT ratio) for monitoring. If the heater current value (CT-A) measured by the CT is less than the heater detection setting value (Alarm Low_CH), the heater burnout alarm will activate. Heater burnout detection only takes place when the temperature controller's output is turned on. Otherwise, heater burnout will not be detected by the controller. Availability of the heater burnout alarm function is different by model and control output type. Model Control output type Heater burnout alarm TM - R (Relay output) Relay output TM4 - S (SSR drive output) TK2 - C (Current or SSR drive output) ON/OFF control Cycle control Phase control Current output SSR drive output Current detection is not performed if OUT control output time is less than 250 ms. It is recommended to use Autonics designated current transformer (for 50 A). Alarm output option can be set to standard alarm (AL-A) or alarm latch (AL-B). X X X Copyright Reserved Autonics Co., Ltd. 71

72 6 Parameter Settings and Functions Heater disconnection detection SV Set the alarm output value (Alarm Low_Ch) as the reference value for heater burnout detection. Setting Factory Setting group Parameter Unit range default Alarm Setting Alarm Low_Ch 0.0 to A Set to 00.0 for OFF. Set to 50.0 for ON. Setting value calculation : Heater burnout setting value = {(normal heater current values) + (heater burnout current)}/2 If using a single output heater (Capacity: 200 VAC, 1 KW, 5 A), normal heater current is 5 A, and burnout heater current is 0 A, the setting value is calculated as (5 A + 0 A)/2 = 2.5 A. Therefore, heater current values less than 2.5 A (heater burnout setting value) will be deemed heater burnout and the alarm will activate. When two output heaters (Capacity: 200 VAC, 1 KW, 5 A) are used, normal heater current is 10 A (5 A 2). If a single heater burns out, the heater current becomes 5A. The setting value is calculated as (10 A + 5 A)/2 = 7.5 A). Heater current values of less than 7.5 A (heater burnout setting value) are deemed heater burnout and the alarm activates. 72 Copyright Reserved Autonics Co., Ltd.

73 6 Parameter Settings and Functions Alarm output OFF Available only if alarm output option is set to alarm latch or alarm latch and standby sequence1, alarm latch and standby sequence2. It can be set to turn off alarm output when alarm output is on, alarm output conditions have been removed, or an alarm output off signal that is greater than the minimal signal band is received. (However, alarm output off is unavailable when alarm conditions remain in effect.) You can assign the digital input terminals (DI-1, DI-2) for the alarm output off feature. For more information about digital terminal (DI) setting, please refer to '6.9.1 Digital input terminal. After deactivating the alarm output, it will function normally for the next alarm output occurrence. Copyright Reserved Autonics Co., Ltd. 73

74 6 Parameter Settings and Functions Alarm output examples (1) Absolute value high-limit alarm and deviation high-limit alarm HYS: Hysteresis (2) Absolute value low-limit alarm and deviation low-limit alarm HYS: Hysteresis 74 Copyright Reserved Autonics Co., Ltd.

75 6 Parameter Settings and Functions (3) Deviation high/low-limit alarm HYS: Hysteresis (4) Deviation high/low-limit reverse alarm HYS: Hysteresis Copyright Reserved Autonics Co., Ltd. 75

76 6 Parameter Settings and Functions (5) Deviation high/low-limit alarm (hysteresis overlap) HYS: Hysteresis 76 Copyright Reserved Autonics Co., Ltd.

77 6 Parameter Settings and Functions 6.5 Communications This feature is used for external higher systems (PC, GP, etc.) to set the controller's parameters and to monitor the controller. It can also be used to external devices. No redundant unit addresses may exist along the same communication line. The communication cable must be twisted pair that supports RS485. (1) Interface Comm. protocol Connection type Application standard Modbus RTU RS485 Compliance with EIA RS485 Max. connection 31 units (address: 01 to 31) Synchronous method Comm. method Comm. method Asynchronous Two-wire half duplex Max. 800m Comm. speed 2400, 4800, 9600(default), 19200, Start bit Data bit Parity bit Stop bit 1-bit (fixed) 8-bit (fixed) None(default), Even, Odd 1-bit, 2-bit (default) Communication address You can assign a unique address to each device. Users can set communication address using both SW1 (communication address setting switch) and SW2 (communication group change switch). Setting range: 01 to 31 Factory default: [SW1] 1, [SW2] +0 SW1 SW A B C D E F If 00 is designated, communications are not performed. Copyright Reserved Autonics Co., Ltd. 77

78 6 Parameter Settings and Functions Communications speed settings You can set the rate of data transmission. Setting group Parameter Setting range Communication Setting Baudrate 2400, 4800, 9600,19200,38400 Factory default Unit 9600 bps A display LED corresponding to the current bps flashes for 5 seconds (1 second intervals) when the power supply is initially ON. Indicator TM2 Series TM4 Series PWR PWR - CH1 CH CH2 CH AL1 CH AL2 CH AL AL4 - - BPS (Bits Per Second) It is required to reset controller's POWER (Power OFF -> Power ON) after changing communication speed (bps) via Power/Comm. connection terminal. One module communication is allowed for PC loader port. Communication speed is fixed to 9600 bps. Make sure that each module has its own communication address. If there are overlapping addresses, parameters for overlapping module cannot be monitored and it may affect the whole communication speed Communications parity bit Parity bit is a data communication method that adds an additional bit to each character in transmitted data as an indicator used to verify data loss and corruption. This parameter is used to enable or disable the parity bit option. SV (setting value) NONE EVEN ODD Description Disables parity bit. Sets the total bits with signal value of 1 as even numbers. Sets the total bits with signal value of 1 as odd numbers. Setting group Parameter Setting range Factory default Unit Communication Setting Parity Bit NONE, EVEN, ODD NONE - 78 Copyright Reserved Autonics Co., Ltd.

79 6 Parameter Settings and Functions Communication stop bit You can set the number of bits to mark the end of a transmitted data string. Setting value Description 1 Sets end of data string to 1 bit. 2 Sets end of data string to 2 bit. Setting group Parameter Setting range Factory default Unit Communication Setting Stop Bit 1, Response wait time Set a standby time to mitigate communication errors when communicating with a slow master device (PC, PLC, etc.). Once a standby time is set, the controller will respond after the defined standby time has elapsed. Setting group Parameter Setting range Communication Setting Response Wait Time Factory default Unit 5 to ms Shorter standby times can cause communication errors in the master device Enable/Disable communications writing This feature can change parameter settings stored in memory through communication with PC, GP, PLC, etc., in order to permit or prohibit writing. Setting value ENABLE DISABLE Description Parameter set/change enable via communication. Prohibit parameter setting or modification via communication. Setting group Parameter Setting range Communication Setting Communication Write Factory default ENABLE, DISABLE ENABLE - Unit Reading parameter settings is always permitted. Copyright Reserved Autonics Co., Ltd. 79

80 6 Parameter Settings and Functions USB-to-Serial connection Data can be transmitted via a USB-to-serial connection. However, RS485 communication through a USB-to-serial connection is blocked by hardware. 80 Copyright Reserved Autonics Co., Ltd.

81 6 Parameter Settings and Functions 6.6 Monitoring function Control output MV monitoring Monitors and displays the current control output MV Heating MV monitoring Displays the current heating MV during heating control or heating and cooling control. Users may manually adjust the MV to control the temperature. Measurement range: 0.0 to 100.0% Cooling MV monitoring Displays the current cooling MV during cooling control or heating and cooling control. Users may manually adjust the MV to control the temperature. Measurement range: 0.0 to 100.0% Heater current monitoring A feature that monitors and displays the current of a heater (load) being controlled by control output. Measurement range: 0.0 to 50.0A The current value of a heater (load) is measured and displayed through the current transformer. Setting group Parameter Setting range Factory default Unit Monitoring Heating_MV 0.0 to % Monitoring Cooling_MV 0.0 to % Monitoring CT1_Heater Current 0.0 to A Monitoring CT2_Heater Current 0.0 to A Availability of the heater current monitoring function is different by model and control output type. Model Control output type Heater current monitoring TM - R (Relay output) Relay output TM4 - S ON/OFF control (SSR drive output) Cycle control X Phase control X TM2 - C Current output X (Current or SSR drive output) SSR drive output Copyright Reserved Autonics Co., Ltd. 81

82 6 Parameter Settings and Functions 6.7 Run/Stop function Users may run or stop control output by force while in Run mode. The STOP command stops the control output. Alarm output, other than control output, maintains the values as set in the alarm output setting at the point of STOP. This feature can be enabled by configuring parameters. The digital input terminals (DI-1 and DI- 2) can be assigned to the run/stop feature. Modifications on RUN/STOP are allowed even when in open state. The STOP status will remain in effect after shutting down the controller and powering it back on. When STOP is in effect, MV based on the control output at the point of STOP (Stop.MV) is displayed, and continues to be displayed even if a sensor break occurs. When restarting after STOP, the initial MV is the MV at the end point. The run/stop setting remains in effect after turning power back on Control output for STOP This sets the control output value upon a STOP. With ON/OFF control, select between 0.0 (OFF) and (ON). In PID control, you can directly choose MV within a range of 0.0 to Setting group Control Setting Preceding condition Heating, Cooling Heating & Cooling PID ON/OFF PID ON/OFF Parameter Stop MV Setting range 0.0 to (OFF)/100.0 (ON) (Cool) to (Heat) (Cool ON) /0.0 (OFF) /100.0 (Heat ON) Factory default Unit % When set to STOP, the preset MV is used for output ignoring the MVs from ON/OFF control and PID control Alarm output for STOP Enable or disable alarm output upon a stop. CONTINUE: Alarm output operates normally. OFF Alarm output ceases along with a stop under all conditions. (However, reverting to Run mode after a stop in alarm latch or alarm latch and standby sequence restores the alarm output to the previous state.) Setting group Parameter Setting range Factory default Unit Control Setting Stop Alarm Out CONTINUE, OFF CONTINUE - 82 Copyright Reserved Autonics Co., Ltd.

83 6 Parameter Settings and Functions 6.8 Multi SV Multi SV function allows users to set multiple SVs and save each setting in SV0 to SV3. User can change Multi SV number or select desired SV using external DI (Digital Input, DI-1, DI-2) terminal. This feature supports up to four SVs which can be independently configurable Number of multi SVs You can set the number of Multi SVs. Select the number of Multi SVs from the controlled subject. Number of SVs 1 SV-0 SV Setting 2 SV-0, SV-1 4 SV-0, SV-1, SV-2, SV-3, Multi SV No. settings You can select the SV to desired control. The SV No. selection range varies according to the number of multi SVs SV for Multi SVs Designate the value of each SV for Multi SVs. Setting group Preceding condition Parameter Setting range Factory default Control Setting - Multi SV 1EA, 2EA, 4EA 1EA Numbers Control Operation Multi SV Multi SV No. SV-0 to SV-3 SV-0 - Control Operation Multi SV SV-0 to SV-3 SV Low-limit to SV High-limit Unit 0, Copyright Reserved Autonics Co., Ltd. 83

84 6 Parameter Settings and Functions 6.9 Digital input Digital input terminal settings When send the signal to the external digital input (DI-1, DI-2) terminal, the settings of the digital input _Func parameter will perform. When powers on, it will activate after checking the digital input terminal. Setting value OFF STOP AL-RESET Manual Multi-SV Description No function. If DI-1,DI-2 terminals are shorted, the stop feature will perform, but to change run/stop through communication will not perform. If DI-1,DI-2 terminals are shorted, the forced deactivation of alarm output will perform, but to deactivate the alarm output through communication will not perform. If DI-1,DI-2 terminals are shorted, the manual control feature will perform, but to change auto/manual control through communication will not perform. By combinational logic of the digital input(di-1,di-2), it is possible to select multi SV NO. (SV-0 to SV-3), but it is not possible to select multi SV NO. through communication. In the case one of DI-1 or DI-2 being set for Multi SV, SV-0 is selected as the SV if the terminal's external contact signal is off and SV-1 is selected if the signal is on. If both DI-1 and DI-2 are configured for Multi SV, you can select the SV using combinational logic of the terminals. If changes multi SV from 4 to 2, the DI-2 will be automatically turned off. If changes multi SV from 4 to 1, both DI-1 and DI-2 will be turned off. DI-1 DI-2 Multi SV No. OFF OFF SV-0 ON OFF SV-1 OFF ON SV-2 ON ON SV-3 Setting group Parameter Setting range Digital Input Setting Factory default Digital Input 1 Func OFF, STOP, AL-RESET OFF - Digital Input 2 Func Manual, Multi-SV OFF - Unit Multi SV parameter will be activated only if Multi SV is more than Digital input terminal target channel Users can set a target channel to which digital input terminal function will be applied. Setting group Parameter Setting range Digital Input Setting Factory default Digital Input1 Ch CH1 - CH1, CH2 Digital Input2 Ch CH2 - Unit 84 Copyright Reserved Autonics Co., Ltd.

85 6 Parameter Settings and Functions 6.10 Error The controller diagnoses input signals for errors and displays messages accordingly. These messages inform the user of device problems. Once the cause of the error is solved (sensor connected/return to display range), the error status is released and the device continues to run normally. The following conditions may result in errors. When an error occurs, the display LED at the front flashes at 0.5 second intervals. The sensor input is higher than operational temperature range. The sensor input is lower than operational temperature range. Input sensor is disconnected or not connected. When power is on, or in standard control or heating mode, the controller outputs 0% if HHHH is displayed and 100% if LLLL is displayed. When power is on, or in standard control or cooling mode, the controller outputs 100% if HHHH is displayed and 0% if LLLL is displayed. In heating and cooling mode, when power is on or in standard control, heating output is 0% and cooling output is 100% if HHHH is displayed; heating output 100% and cooling output is 0% if LLLL is displayed. Output priority in manual control: Heating(Cooling)_MV > Stop_MV > Sensor Error_MV Output priority in automatic control: Stop_MV > Sensor Error_MV > Heating(Cooling)_MV Sensor error, MV setting This feature sets control output when a sensor open error occurs. Users can configure ON/OFF, MV settings, etc. Ignores MV by ON/OFF control or PID control, and sends out a control value based on the defined MV. Setting group Control Setting Preceding condition Heating, PID Cooling ON/OFF Heating & Cooling PID ON/OFF Parameter Sensor Error MV Setting range 0.0 to (OFF)/100.0 (ON) (Cool) to (Heat) (Cool ON) /0.0 (OFF) /100.0 (Heat ON) Factory default Unit % Copyright Reserved Autonics Co., Ltd. 85

86 6 Parameter Settings and Functions 6.11 Parameter initialization This option resets all parameters in memory to factory defaults. Setting group Parameter Setting range Factory default Communication Setting Parameter Initialize YES, NO NO - Unit If selecting "Yes", all parameters will be initialized and temperature control will be by factory default. However, communication parameters are not initialized. 86 Copyright Reserved Autonics Co., Ltd.

87 7 Simple Error Diagnosis 7 Simple Error Diagnosis 7.1 Error display Indicator PWR (red) Status Disconnected input sensors ON Out of temperature range CH (red) 1 Flash (for 0.5 sec. in turn) Comm. output (decimal) DAQMaster Outputs '31000' Displays 'OPEN' 1. The applied CH LED indicator flashes. Outputs '30000(high-limit)', '-30000(low-limit)' Displays 'HHHH(high-limit)', 'LLLL(low-limit)' 7.2 Trobleshootings (1) LED indicators flash (for 0.5 sec. in turn), or external device displays OPEN Check input sensor setting. Disconnect the power and check the input connection. If input is connected, disconnect the input wiring from the temperature controller and short the + and - terminals. Power the temperature controller and check if the external device displays the room temperature. If it does not display the room temperature and continues to display HHHH or LLLL, the controller is broken. Please contact our technical support. (input type is thermocouple) (2) Output does not operate normally. Check that CH indicators for control output operates normally. If CH indicators for control output does not operates, check the parameter settings. If CH indicators for control output operates, remove the control output connector and check the output. (3) External device receives no-response or abnormal data. Check the communication converter (SCM-38I, SCM-US48I or SCM-US, sold separately). Do not install communication converter line and AC power supply lines. Use different communication converter power and temperature controller power. Indicates damage to internal chip by strong noise. Please contact our technical support. Locate the source of the noise device countermeasures. (4) Communication does not work between TM and external device Check the communication converter power and connections. Check the communication settings. Check the temperature controller and external device connections. Copyright Reserved Autonics Co., Ltd. 87

88 7 Simple Error Diagnosis 88 Copyright Reserved Autonics Co., Ltd.

89 8 DAQMaster 8 DAQMaster 8.1 Overview DAQMaster is a comprehensive device management program that can be used with Autonics communication supporting products. DAQMaster provides GUI control for easy and convenient management of parameters and multiple device data monitoring. For more information, visit our website ( to download "DAQMaster user manual. Copyright Reserved Autonics Co., Ltd. 89

Thank you for purchasing an Autonics product.

Thank you for purchasing an Autonics product. User Manual Preface Preface Thank you for purchasing an Autonics product. Please familiarize yourself with the information contained in the Safety Precautions section before using this product. This user

More information

R Relay output S SSR drive output C Selectable current output or SSR drive output VAC 50/60Hz

R Relay output S SSR drive output C Selectable current output or SSR drive output VAC 50/60Hz Controller Features Super high-speed sampling with 50ms Improved visibility with LCD display Communication function supported: RS485 (Modbus RTU) Convenient parameter setting (RS485 communication) : Free

More information

Option output. 0 None. 4 RS485 communication output. 0 None. Alarm output. CH2 control output. 0 None. CH1 control output. 0 None

Option output. 0 None. 4 RS485 communication output. 0 None. Alarm output. CH2 control output. 0 None. CH1 control output. 0 None Series Features 50mm thermal transfer method of paper recorder Data logger function for recording without paper Supports RS485 communication and dedicated communication port to set or monitor parameters

More information

Series Temperature Controller Instruction Sheet

Series Temperature Controller Instruction Sheet Series Temperature Controller Instruction Sheet Thank you very much for purchasing DELTA A Series. Please read this instruction sheet before using your A series to ensure proper operation and please keep

More information

Thank you for purchasing an Autonics product.

Thank you for purchasing an Autonics product. User Manual Preface Preface Thank you for purchasing an Autonics product. Please familiarize yourself with the information contained in the Safety Precautions section before using this product. This user

More information

Series Digital Controller Instruction Sheet

Series Digital Controller Instruction Sheet 216/3/11 Series Digital Controller Instruction Sheet Thank you very much for purchasing DELTA DTC Series Temperature Controller. Please read this instruction sheet before using your DTC series to ensure

More information

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl enproteko.com Temperature Monitoring Relay K8AB-TH Compact and Slim Relay Ideal for Temperature Alarms and Monitoring Excessive increases can be prevented and abnormal s can be monitored. Temperature monitoring

More information

1 Product Introduction USER MANUAL. Copyright Reserved Autonics Co., Ltd. 1

1 Product Introduction USER MANUAL. Copyright Reserved Autonics Co., Ltd. 1 1 Product Introduction USER MANUAL Copyright Reserved Autonics Co., Ltd. 1 1 Product Introduction 2 Copyright Reserved Autonics Co., Ltd. 1 Product Introduction Preface Thank you for purchasing an Autonics

More information

Instruction manual Temperature Controller KT7

Instruction manual Temperature Controller KT7 Instruction manual Temperature Controller KT7 No. KT71E7 201.05 To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual. SAFETY PRECAUTIS Be sure

More information

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER JCD-13A, JCR-13A

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER JCD-13A, JCR-13A INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER JCD-13A, JCR-13A Preface Thank you for the purchase of our Microcomputer based Temperature Indicating Controllers JCD-13A or

More information

CN-6000 Series. Features. Ordering information CN C1. Part descriptions. 5 ( key: Used to enter parameter set mode, move to parameters,

CN-6000 Series. Features. Ordering information CN C1. Part descriptions. 5 ( key: Used to enter parameter set mode, move to parameters, CN-6000 eries Features Multi-input CN-610 : Thermocouple 12 types, RTD 5 types, Analog (mv, V, ma) 6 types CN-640 : 0 to 50.00kHz Improves visibility with negative LCD : 12 segment, 3 colors (selectable

More information

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail Temperature Controller General Description The is a socket mounting type temperature controller and is available for mounting inside the panel or by easily mounting on DI rail. The has features such as

More information

CN-6000 Series. Features. Ordering information CN C1. Part descriptions. 5 ( key: Used to enter parameter set mode, move to parameters,

CN-6000 Series. Features. Ordering information CN C1. Part descriptions. 5 ( key: Used to enter parameter set mode, move to parameters, CN-6000 eries Features Multi-input CN-610 : Thermocouple 12 types, RTD 5 types, Analog (mv, V, ma) 6 types CN-640 : 0 to 50.00 khz Improves visibility with negative LCD : 12 segment, 3 colors (selectable

More information

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS NOVA PD56 Series Thermocouple, RTD, & Process Inputs Universal Power Supply 1-24 VAC Up to 3 Alarm Relays Retransmitting 4-2 ma Output Input Max/Min

More information

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Process & TeMPerATUre UniversAl input DigiTAl MeTers Process & TeMPerATUre UniversAl input DigiTAl MeTers nova PD56 series Thermocouple, rtd, & Process inputs Universal Power supply 1-24 va c Up to 3 Alarm relays retransmitting 4-2 ma output input Max/Min

More information

Warning Caution INSTRUCTION MANUAL DIN RAIL MOUNTING TYPE INDICATING CONTROLLER

Warning Caution INSTRUCTION MANUAL DIN RAIL MOUNTING TYPE INDICATING CONTROLLER INSTRUCTI MANUAL DIN RAIL MOUNTING TYPE INDICATING CTROLLER 1 DCL-A DC No.DCLDCE1 2007.01 Thank you for purchasing our DIN rail mounting type indicating controller DCL-A DC. This manual contains instructions

More information

Instruction manual for DIN rail mounting type indicating controller DCL-33A

Instruction manual for DIN rail mounting type indicating controller DCL-33A Instruction manual for DIN rail mounting type indicating controller DCL-33A To prevent accidents arising from the misuse of this controller, please ensure the operator using it receives this manual. Caution

More information

SA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting

SA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting Temperature Controller General Description The is a high performance 3 nd DI controller that has been specifically designed for applications where panel space is critical. Though small in size, this controller

More information

Temperature Controllers

Temperature Controllers Model TEC-4100 1/4 DIN Model TEC-4100 1/4 DIN Temperature Controller Ordering Code: Power Input BOX 1 4 = 90-250 VAC 5 = 11-26 VAC / VDC TEC-4100- Configurable for 4 Programmable Outputs and NEMA 4X/IP65

More information

DIGITAL INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL

DIGITAL INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL DIGITAL INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL Preface Thank you for purchasing our Digital indicating controller FCS-23A. This manual contains instructions for the mounting, functions, operations

More information

Universal controller for panel mounting Models CS6S, CS6H, CS6L

Universal controller for panel mounting Models CS6S, CS6H, CS6L Accessories Universal controller for panel mounting Models CS6S, CS6H, CS6L WIKA data sheet AC 85.08 Applications Plant and industrial furnace construction Process engineering Plastics technology and processing

More information

Micro-controller X C C1 C2 AL1 AL2 AL3. Model: PXR4/5/9. Operation Manual SEL PXR. ECNO:406e

Micro-controller X C C1 C2 AL1 AL2 AL3. Model: PXR4/5/9. Operation Manual SEL PXR. ECNO:406e C C1 C2 AL1 AL2 AL3 Micro-controller X Model: PXR4/5/9 PXR SEL Operation Manual ECNO:46e Table of Contents Part Names and Functions... 6 Operations... 7 2-1 Parameter list... 7 2-2 Basic operations...

More information

F4 Process Controller Installation and Operation Guide

F4 Process Controller Installation and Operation Guide F4 Process Controller Installation and Operation Guide 1.Introduction 1.1.Highlight Features Space saving, only 55mm panel depth required Higher sampling rate (1mS) results in better control performance

More information

INSTRUCTION MANUAL Micro-computer based digital indicating controller

INSTRUCTION MANUAL Micro-computer based digital indicating controller INSTRUCTI MANUAL Micro-computer based digital indicating controller TP4A To prevent accidents arising from the misuse of this controller, please ensure the operator using it receives this manual. Caution

More information

DCL-33A No.DCL31E To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual.

DCL-33A No.DCL31E To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual. INSTRUCTI MANUAL DIN RAIL MOUNTING TYPE INDICATING CTROLLER DCL-A No.DCL1E5 200.08 To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual. SAFETY

More information

TEMPERATURE CONTROL MODULE MODEL R3-TC2

TEMPERATURE CONTROL MODULE MODEL R3-TC2 INSTRUCTION MANUAL R3-TC2 TEMPERATURE CONTROL MODULE MODEL R3-TC2 CONTENTS BEFORE USE... 2 POINTS OF CAUTION... 2 COMPONENT IDENTIFICATION... 2 INSTALLATION... 2 EXTERNAL DIMENSIONS unit: mm (inch)...

More information

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER FCS-23A

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER Thank you for your purchase of our Microcomputer based Temperature Indicating Controller. This manual contains instructions

More information

Instruction manual Micro-computer based digital indicating controller

Instruction manual Micro-computer based digital indicating controller Instruction manual Micro-computer based digital indicating controller JCS-33A To prevent accidents arising from the misuse of this controller, please ensure the operator using it receives this manual.

More information

DIGITAL INDICATOR JIR-301-M

DIGITAL INDICATOR JIR-301-M DIGITAL INDICATOR JIR-301-M Instruction Manual Preface Thank you for purchasing our digital indicator JIR-301-M. This manual contains instructions for the mounting, functions, operations and notes when

More information

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03 Digital Controller A 96 x 96-mm (DIN) Digital Process Controller Optimum PID control with feed-forward control circuitry. High accuracy (+0.3% FS +1 digit max.). Replaceable Output Units. Models with communications

More information

(Except 12-24VDC) Control output 12-24VDC. Power consumption Max. 8W Max. 4VA Max. 8W Max. 4VA Max. 8W Max. 4VA

(Except 12-24VDC) Control output 12-24VDC. Power consumption Max. 8W Max. 4VA Max. 8W Max. 4VA Max. 8W Max. 4VA TC3YF Freezing/ type DIN W72 H36mm Freezing/ type Features ON/ Control Input specification - Basic specification: NTC(Thermistor), Option: RTD(DPt100Ω) Temperature display range NTC type: -40.0 to 99.9

More information

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER 1 VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER 1. INTRODUCTION This manual contains information for the installation and operation and tuning of our Vertex VT10 series self-tuning

More information

TEMPERATURE CONTROLLER

TEMPERATURE CONTROLLER TEMPERATURE CONTROLLER E5CX(-H) DIN-sized super-compact (48 x 48-mm) Temperature Controller Featuring Advanced PID Control Advanced PID control with two degrees of freedom improves stability and response

More information

Non-contact voltage (for SSR drive): V DC DC current: 4 to 20mA DC Thermocouple: K, J, E Input. RTD: Pt100, JPt100

Non-contact voltage (for SSR drive): V DC DC current: 4 to 20mA DC Thermocouple: K, J, E Input. RTD: Pt100, JPt100 INSTRUCTI MANUAL Micro-computer based Temperature Indicating Controller 1 GCS-00 No.GCS1E 200.11 To prevent accidents arising from the use of this controller, please ensure the operator receives this manual.

More information

GCS-300 No.GCS31E

GCS-300 No.GCS31E INSTRUCTI MANUAL Micro-computer based Temperature Indicating Controller GCS-00 No.GCS1E 200.0 To prevent accidents arising from the use of this controller, please ensure the operator receives this manual.

More information

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma) TEMPERATURE CONTROLLER DIN-sized (96 x 96-mm) Temperature Controller Featuring Advanced PID Control and Heater Burnout Detection Advanced PID control with two degrees of freedom to improve stability and

More information

Temperature Controller

Temperature Controller E5AN Temperature Controller Temperature Controller OMRON Corporation Industrial Automation Company Industrial Devices and Components Division H.Q. Measuring Components Department Shiokoji Horikawa, Shimogyo-ku,

More information

TCN Series. Economical Dual Display Type, PID Control. Economical Dual Display Type, PID Control Features. Ordering Information.

TCN Series. Economical Dual Display Type, PID Control. Economical Dual Display Type, PID Control Features. Ordering Information. TCN eries Economical Dual Type, PID Control Economical Dual Type, PID Control Features Realizes ideal temp. controlling with newly developed PID control algorithm and 100ms high speed sampling Built-in

More information

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0) Serie 5000 Tel. +1 (0)5 222 Fax +1 (0)5 222 12 PRODUCT INTRODUCTI PRODUCT INTRODUCTI 5 Series programmable temperature controller is FineTek's mid-range series of controllers. It uses a 12bit analog /

More information

+ A B V B NO NC V COM PV PV

+ A B V B NO NC V COM PV PV + - A + B B - V + - NO NC COM + - + - V + - PV PV Ramp Soak 100 70 50 30 3 5 3 8 5 3 Minute Steam Heating Sensor Cooling Water PID Hotplate Specifications Input power supply AC 100 to 240V, 50/60Hz, DC

More information

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER GCD-200, GCR-200

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER GCD-200, GCR-200 INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER GCD-200, GCR-200 PV PV AT AT OUT1 OUT2/HB A1 A2 OUT1 OUT2/HB A1 A2 MODE OUT MODE OUT GCD GCR Preface Thank you for the purchase

More information

MICRO CONTROLLER S Z SERIES

MICRO CONTROLLER S Z SERIES Instruction Manual MICRO CONTROLLER S Z SERIES TYPE: PYW 4 5 7 9 Fuji Electric Co.,Ltd. INP-TN1PYWf-E INTRODUCTION You are now the owner of Fuji's digital Temperature Controller. Before using, be sure

More information

Safety Information. Functional Description. Operation. DANGER Do not touch or contact the input/output terminals because it may cause electric shock.

Safety Information. Functional Description. Operation. DANGER Do not touch or contact the input/output terminals because it may cause electric shock. Temperature Controller KXN Series INSTRUCTION MANUAL Thank you for purchasing HANYOUNG NUX CO,.Ltd. Product. Please check whether the prouduct you purchased is the exactly same as you ordered. Before using

More information

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications Instruction Manual Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications Manual PCT30006, Revision 9/20/2016 The PCT30006 control enclosure incorporates

More information

DIN RAIL MOUNTED INDICATING CONTOLLER DCL-33A INSTRUCTION MANUAL

DIN RAIL MOUNTED INDICATING CONTOLLER DCL-33A INSTRUCTION MANUAL DIN RAIL MOUNTED INDICATING CONTOLLER DCL-A INSTRUCTION MANUAL Preface Thank you for purchasing our DIN rail mounted indicating controller DCL-A. This manual contains instructions for the mounting, functions,

More information

02/11/2015

02/11/2015 MIC48 With RS 485 link Part number 89422418 Heating and / or cooling function 2 independent alarms Load break detection 2 setpoint which can be selected remotely Manual / automatic power adjustment RS

More information

Advanced Ultraviolet Burner Controller

Advanced Ultraviolet Burner Controller No. CP-SS-7E Advanced Ultraviolet Burner Controller Model AUR300C/AUR30C Overview The AUR300C Advanced Ultraviolet Burner Controller and AUR30C Advanced Ultraviolet Burner Controller with Communication

More information

Analog Room Pressure Monitor RPC Series

Analog Room Pressure Monitor RPC Series Description The Room Pressure Monitor is used to measure differential pressure in the range of 0.125 to 1"wc or 30 to 250 Pa. It combines precision high sensitivity silicon sensing capabilities and the

More information

02/11/2015

02/11/2015 CTH 46 - CTD 43 / 46 CTD 46 Part number 89422108 CTH 46 Heating / cooling function Measurement and setpoint display CTD 43 Heating or cooling function Measurement display Measurement deviation display-setpoint

More information

I/A Series 716C 1/16 DIN Temperature Controller

I/A Series 716C 1/16 DIN Temperature Controller Product Specifications I/A Series 716C 1/16 DIN Temperature Controller PSS 2C-1B5 A The Foxboro 716C is a powerful compact, 1/16 DIN, microprocessor-based temperature controller that offers a variety of

More information

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller No. CP-SS-7E Overview The AUR300C is a burner controller with a dynamic selfchecking function and is used in combination with the AUD300C or AUD00C Advanced Ultraviolet Flame Detector. This AUR300C controls

More information

INSTRUCTION MANUAL FOR TOUCH PANEL MONITORING UNIT CMT-220-K

INSTRUCTION MANUAL FOR TOUCH PANEL MONITORING UNIT CMT-220-K INSTRUCTION MANUAL FOR TOUCH PANEL MONITORING UNIT PREFACE Thank you for your purchase of our Touch panel monitoring unit. This manual contains instructions for the mounting, functions, operations and

More information

UDC 700 Universal Digital Controllers and Indicator Specifications

UDC 700 Universal Digital Controllers and Indicator Specifications UDC 700 Universal Digital Controllers and Indicator Specifications 51-52-03-28 August 2002 Overview The UDC 700 is a 1/32 DIN (49 x 25 mm) controller which combines a high degree of technology and quality

More information

CN4800 Series CONTROLLER

CN4800 Series CONTROLLER CN4800 Series CONTROLLER Operator's Manual PV SV OUT1 OUT2 ALM1 ALM2 SEL M1791/0502 Contents I. PREPARING THE OPERATION... 4 1. THE BASIC INSTALLATION PROCEDURE... 5 2. CHECK OF SPECIFICATIONS... 6 2.1

More information

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual. INSTRUCTION MANUAL MICRO-COMPUTER BASED DIGITAL INDICATOR JIR-31-M No.JIR31E3 24.7 To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual. SAFETY

More information

1. Model ACS 1 3 A / A, Series name: ACS-13A- /A (W48 x H48 x D62mm) Control action 3 PID A1 A Alarm type can be selected by keypad.

1. Model ACS 1 3 A / A, Series name: ACS-13A- /A (W48 x H48 x D62mm) Control action 3 PID A1 A Alarm type can be selected by keypad. INSTRUCTI MANUAL (EXCERPT) Digital Indicating Controller ACS-13A- /A (For Use with the Infrared Temperature Sensor RD-500) No.ACS11AE1 2011.07 The digital indicating controller ACS-13A /A is an exclusive

More information

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS EN0I-6041 4/01 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1000 and UDC1500 are microprocessor-based 1/16 DIN and 1/8 DIN controllers

More information

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications Instruction Manual Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications Manual PCT-3000 Revision 9/2014 The PCT-3000 series control console incorporates

More information

OVEN INDUSTRIES, INC.

OVEN INDUSTRIES, INC. OVEN INDUSTRIES, INC. OPERATING MANUAL Model 5C7-252 TEMPERATURE CONTROLLER With PLC Inputs Introduction Thank you for purchasing our controller. The Model 5C7-252 is an exceptionally versatile unit and

More information

Digital Heater Element Burnout Detector K8AC-H

Digital Heater Element Burnout Detector K8AC-H Digital Heater Element Burnout Detector K8AC-H A high-precision Heater Element Burnout Detector compatible with a wide-range of heater control methods. Push-in terminals reduce the workload. *1 Scaling

More information

Example of Applications and Parameter Functions

Example of Applications and Parameter Functions PX-series digital temperature controller Example of Applications and Functions ECNO:1158 I. Example of Applications 1 Controlling both heating and cooling with a single controller Only one controller is

More information

Communications type RS-232C RS-422 RS-485 E5AJ-A2H02 E5EJ-A2H02

Communications type RS-232C RS-422 RS-485 E5AJ-A2H02 E5EJ-A2H02 Temperature Controller Fuzzy Self-tuning Temperature Controller with Advanced PID (2-PID) Control DIN-size: 6 x 6 mm (E5AJ), 2 x 2 mm (E5BJ), 4 x 4 mm (E5CJ), 4 x 6 mm (E5EJ) Fuzzy self-tuning and Auto-tuning

More information

TC515 and TC600 Installation Manual. a Winters company

TC515 and TC600 Installation Manual. a Winters company THERMOLINE TEMPERATURE CONTROLLERS TC515 and TC600 Installation Manual a Winters company Guarantee 12 months Congratulations on the purchase of this new product. Special care with the design, workmanship

More information

7EF/7HF/7EC/7ES Temperature Controllers

7EF/7HF/7EC/7ES Temperature Controllers 7EF/7HF/7E/7ES Temperature ontrollers Dual 4 Digit LED Display Universal Input (6 T/, RTD, mv, V, ma) Autotuning NEMA 4X 100 to 240 Vac Switching Power Supply Algorithms for Heat or Heat/ool ontrol 2 Independent

More information

ARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER

ARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER ARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER AI-208 (V7.6) User Manual I. Model Code Symbol The type of AI-208 is made up of 4 parts: AI-208 A G L2 Part 1 (Series) Part 2 (Size) Part 3 (Oupt) Part 4

More information

RS485 MODBUS Module 8AI

RS485 MODBUS Module 8AI Version 1.4 15/04/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

DIGITAL INDICATOR DI25

DIGITAL INDICATOR DI25 DIGITAL INDICATOR DI25 Operating instructions Preface Thank you for purchasing our digital indicator DI25. This manual contains instructions for the mounting, functions, operations and notes when operating

More information

Nov 08 PRODUCT SPECIFICATION SHEET

Nov 08 PRODUCT SPECIFICATION SHEET Honeywell UDC1200 and UDC1700 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS 51-52-03-35 Nov 08 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1200 & UDC1700 are microprocessor-based 1/16 DIN and 1/8 DIN

More information

E5CN Temperature Controller User s Manual

E5CN Temperature Controller User s Manual E5CN Temperature Controller User s Manual Revised July 2003 Notice: OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in

More information

PLC INTERFACE UNIT CIT-200 INSTRUCTION MANUAL

PLC INTERFACE UNIT CIT-200 INSTRUCTION MANUAL PLC INTERFACE UNIT CIT-200 INSTRUCTION MANUAL PREFACE Thank you for the purchase of our PLC Interface Unit CIT-200. This manual contains instructions for the mounting, functions, operations and notes when

More information

Oakton TEMP 9500 Advanced Multiparameter Controller

Oakton TEMP 9500 Advanced Multiparameter Controller Oakton TEMP 9500 Advanced Multiparameter Controller Models: 89800-03 & 89800-04 Oakton Instruments 625 E Bunker Ct. Vernon Hills, IL 60061, USA 1-888-4OAKTON (1-888-462-5866) info@4oakton.com Contents

More information

Cat. No. H113-E1-03B E5ZN. Temperature Controller OPERATION MANUAL

Cat. No. H113-E1-03B E5ZN. Temperature Controller OPERATION MANUAL Cat. No. H113-E1-03B E5ZN Temperature Controller OPERATION MANUAL E5ZN Temperature Controller Operation Manual Revised November 2005 Notice: OMRON products are manufactured for use according to proper

More information

User's Manual. Model VJQ8 Pulse to Analog Converter. (Multi-function) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT

User's Manual. Model VJQ8 Pulse to Analog Converter. (Multi-function) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT User's Manual Model VJQ8 Pulse to Analog Converter (Multi-function) (Isolated Single-output and Isolated Dualoutput Types) Thank you for purchasing the JUXTA Signal Conditioner. Please read through this

More information

Specification , July 2015

Specification , July 2015 Technical Information PrecisionLine Controllers EDC21 / EDC22 / EDC23 EASYSET DIGITAL CONTROLLERS Specification 51-52-3-48, July 215 Introduction The EDC21, EDC22 and EDC23 controllers provide precise

More information

Carbon Monoxide Transmitter

Carbon Monoxide Transmitter Introduction The CO Transmitter uses an electrochemical sensor to monitor the carbon monoxide level and outputs a field-selectable 4-20 ma or voltage signal. The voltage signal may also be set to 0-5 or

More information

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs User Manual Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs Models 89800-03 and 89800-04 THE STANDARD IN PRECISION MEASUREMENT Table of Contents

More information

High Resolution Temperature Controller REX-F9000. Instruction Manual IM9000F01-E5 RKC INSTRUMENT INC.

High Resolution Temperature Controller REX-F9000. Instruction Manual IM9000F01-E5 RKC INSTRUMENT INC. High Resolution Temperature Controller REX-F9000 Instruction Manual RKC INSTRUMENT INC. IM9000F01-E5 All Rights Reserved, Copyright 1999, RKC INSTRUMENT INC. Thank you for purchasing this RKC product.

More information

COMPLIANT MANAGER. Installation Manual. Model name: BMS-CM1280TLE BMS-CM1280FTLE. Save These Instructions! ENGLISH

COMPLIANT MANAGER. Installation Manual. Model name: BMS-CM1280TLE BMS-CM1280FTLE. Save These Instructions! ENGLISH COMPLIANT MANAGER Model name: BMS-CM1280TLE BMS-CM1280FTLE Save These Instructions! ENGLISH Contents 1 PRECAUTIONS FOR SAFETY........................................... 3 2 PACKAGED ITEMS OF COMPLIANT

More information

SYL-1512A PID TEMPEARATURE CONTROLLER INSTRUCTION MANUAL Version 2.1

SYL-1512A PID TEMPEARATURE CONTROLLER INSTRUCTION MANUAL Version 2.1 SYL-1512A PID TEMPEARATURE CONTROLLER INSTRUCTION MANUAL Version 2.1 Jun. 2007 Auber Instruments, 730 Culworth, Alpharetta, GA 30022 www.auberins.com e-mail: auberins@gmail.com Tel: 404-291-6298 WARNING

More information

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input User Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with

More information

USER MANUAL. Copyright Reserved Autonics Co., Ltd. iii

USER MANUAL. Copyright Reserved Autonics Co., Ltd. iii USER MANUAL Copyright Reserved Autonics Co., Ltd. iii ii Copyright Reserved Autonics Co., Ltd. Preface Preface Thank you for purchasing Autonics product. Please familiarize yourself with the information

More information

4TEMPERATURE CONTROLLER

4TEMPERATURE CONTROLLER Universal Input Output and High Accuracy 0.5 class 250ms TEMPERATURE ONTROLLER RAMP function PID Auto-tuning Universal input /, Reverse/Direct action selectable Remote/Local input selectable Model and

More information

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual. INSTRUCTI MANUAL MICRO-COMPUTER BASED DIGITAL INDICATOR JIR-31-M No.JIR31E6 28.8 To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual. SAFETY

More information

TAIE. Features. FY600 (96mm X 48mm) Application:Control temperature,humidity, FY Series Digital PID Controller

TAIE. Features. FY600 (96mm X 48mm) Application:Control temperature,humidity, FY Series Digital PID Controller TAIE FY Series Digital PID Controller FY600 (96mm X 48mm) Application:Control temperature,humidity, FY series controllers are microprocessor based controllers. Which have been Designed with high accuracy

More information

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs User Manual Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs Models 89800-13 and 89800-14 THE STANDARD IN PRECISION MEASUREMENT Table of Contents

More information

MICRO CONTROLLER E Z SERIES

MICRO CONTROLLER E Z SERIES Instruction Manual MICRO CONTROLLER E Z SERIES TYPE: PYZ 4 5 7 9 Fuji Electric Co.,Ltd. INP-TN2PYZDe-E INTRODUCTION You are now the owner of Fuji's Digital Temperature Controller. Before using, be sure

More information

CB103/CB403/CB PRODUCT CHECK 2. MOUNTING - * - / /Y INSTRUCTION MANUAL WARNING. 2.1 Mounting Cautions CAUTION RKC INSTRUMENT INC.

CB103/CB403/CB PRODUCT CHECK 2. MOUNTING - * - / /Y INSTRUCTION MANUAL WARNING. 2.1 Mounting Cautions CAUTION RKC INSTRUMENT INC. Digital Controller CB/CB4/CB9 INSTRUCTI MANUAL IMCBE7 Thank you for purchasing this RKC product. In order to achieve maximum performance and ensure proper operation of your new instrument, carefully read

More information

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations. 1 P age Ezeio v9-120317 Eze Cloud Based Monitoring Systems. Created by Intech Instruments Ltd December 2014 Important Supplementary Manual to the main Ezeio manual. Ezeio Controller and the 2400-A16 input

More information

AutomationDirect. PC35 Configuration Sheet

AutomationDirect. PC35 Configuration Sheet Part#: Project: AutomationDirect PC35 Configuration Sheet Name: Date: Main Setpoint (): Cycle 5 INPUT DEFAULT CODE/VALUE Type 1 Dppo OFF Unit [ Offs 0 Spll -150 Spkl 1370 Rsll -150 Rskl 1370 Cycle 6 I/O

More information

PACSystems* RX3i. Thermocouple Input Module, 12 Channels, IC695ALG412. GFK-2578B October 2011

PACSystems* RX3i. Thermocouple Input Module, 12 Channels, IC695ALG412. GFK-2578B October 2011 October 2011 PACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412 The PACSystems * Thermocouple Input module IC695ALG412 provides twelve isolated differential thermocouple input channels.

More information

DIGITAL INDICATING CONTROLLER. BCx2 INSTRUCTION MANUAL

DIGITAL INDICATING CONTROLLER. BCx2 INSTRUCTION MANUAL DIGITAL INDICATING CONTROLLER BCx2 INSTRUCTION MANUAL Preface Thank you for purchasing our digital indicating controller BCx2 (BCS2, BCR2, BCD2). This manual contains instructions for the mounting, functions,

More information

Multi-point Digital Controller MA900/MA901. Initial Setting Manual IMR01H03-E4 RKC INSTRUMENT INC.

Multi-point Digital Controller MA900/MA901. Initial Setting Manual IMR01H03-E4 RKC INSTRUMENT INC. Multi-point Digital Controller MA900/MA901 Initial Setting Manual RKC INSTRUMENT INC. IMR01H03-E4 !"Modbus is a registered trademark of Schneider Electric.!"Company names and product names used in this

More information

General Specifications

General Specifications General Specifications GS J0H-0E Model MVHK Digital Limit Alarm (DC Type) with Active Color PV Display General This plug-in type Digital Limit Alarm for DC input receives DC current or DC voltage signal.

More information

CLEANROOM MONITOR CR3A Network - Installation Instructions

CLEANROOM MONITOR CR3A Network - Installation Instructions CLEANROOM MONITOR CR3A Network - Installation Instructions INTRODUCTION The CR3 Series Cleanroom Monitor, was developed specifically to allow for monitoring of confined spaces with accuracy and reliability.

More information

SHIMADEN DIGITAL INDICATORS

SHIMADEN DIGITAL INDICATORS Shimaden, Temperature and Humidity Control Specialists C %RH MICROPROCESSOR-BASED SHIMADEN DIGITAL INDICATORS & NRTL /C approved BASIC FEATURES DIN Size 48 x 96 mm ±.25% High Accuracy Indication User-Selectable

More information

SR Mini HG SYSTEM. High-performance Multi-point Control System. SR Mini HG SYSTEM. Hardware Instruction Manual IMSRM15-E6 RKC INSTRUMENT INC.

SR Mini HG SYSTEM. High-performance Multi-point Control System. SR Mini HG SYSTEM. Hardware Instruction Manual IMSRM15-E6 RKC INSTRUMENT INC. SR Mini HG SYSTEM High-performance Multi-point Control System SR Mini HG SYSTEM Hardware Instruction Manual RKC INSTRUMENT INC. IMSRM15-E6 Modbus is a registered trademark of Schneider Electric. The name

More information

TAIE. Features. FY900 (96mm X 96mm) Application:Control temperature,humidity, FY Series Digital PID Controller

TAIE. Features. FY900 (96mm X 96mm) Application:Control temperature,humidity, FY Series Digital PID Controller TAIE FY Series Digital PID Controller FY900 (96mm X 96mm) Application:Control temperature,humidity, FY series controllers are microprocessor based controllers. Which have been Designed with high accuracy

More information

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1- DPR-45 User Manual V-2.0 (2..206) DPR-45 TEMPERATURE PROTECTION RELAY PT00 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT 9-50VDC SUPPLY DESCRIPTION DPR-45 is a precision unit designed for the temperature

More information

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA 99336 www.jmcvr.com 1-509-586-9893 Table of Contents TABLE OF FIGURES...1 OVERVIEW OF THE HRC CAPABILITIES...2 INSTALLATION AND

More information

Module Features are-configurable, no module jumpers to set

Module Features are-configurable, no module jumpers to set December 2011 PACSystems* RX3i Isolated Thermocouple Input Module, 6 Channels, IC695ALG306 Isolated Thermocouple Input Module, 12 Channels, IC695ALG312 Isolated Thermocouple Input module IC695ALG306 provides

More information