1 MC 785TKLIMA wall and panel mount User manual Description : MC 785T KLIMA Thermo/Hygrostat with realtime clock Doc.nr.: 8626 Type: Manual Number of pages: 15 Version: V1. Bestand: Do8626 MC785T KLIMA v1 EN.wpd Software: KLIMA t LAM Version: V1. By: HN Date: VDH Products BV Roden Holland Signed: File: Doc8
2 User manual Document nr. : 8626 Version : V1. MC 785TKLIMA Client : General Page : 2 from 15 Table of contents 1. Technical specifications Functional specifications Control Programming internal parameters Working Relay outputs Sensor calibration Alarms Front view Connections Dimensions The information contained in this document is assumed to be accurate. However VDH Products BV accepts no liability for eventual mistakes or errors and has the right to change this document without notice.
3 User manual Document nr. : 8626 Version : V1. MC 785TKLIMA Client : General Page : 3 from Technical specifications General Type : MC 785 KLIMA Wall mount version: Housing : Grey plestic Material : Polystyrol 454h KG 2 natur BASF Dimensions : 213 x 18 x 85mm (whd) Front : Polycarbonate (IP44) Panel mount version: Housing : Steel case for panel mount Material : Steel silver grey painted Dimensions : 217 x 155 x 85mm (whd) Panel cut : min. 28 x 146mm (wh) Front : Polycarbonate (IP44) Temperature range : 4/+5 C per,1 C Rel. humidity range : /+1% RH per,1% RH Power supply : 23 Vac; 5/6 Hz (1/+5%). Power consumption : 9 VA perating temperature : 2/+5 C perating rel. humidity : 1/+9 % RH not condensing Accuracy : ±,5 % of the range Front Display : 4digit digital display for measured temperature 4digit digital display for temperature set point 4digit digital display for measured RH and time with 7 day leds 4digit digital display for RH set point Led's : = Led Relay cooling active = Led Relay heating active = Led Relay dehumidifying active = Led Relay humidifying active = Led Alarm active (flashing) 1 = Led Set point1 active 2 = Led Set point2 active Keys : N/FF = n/off key controller SET C = Temperature set point key SET = Humidity set point key = Up key = Down key PRG = Programming key START/STP = Start/stop key week program clock = Clock key RESET ALARM = Alarm reset key
4 User manual Document nr. : 8626 Version : V1. MC 785TKLIMA Client : General Page : 4 from 15 In and utputs Sensors : Temperature sensor (Pt1, 3wire according DIN/IEC 751) RH sensor (/+1 Vdc = /+1% RH) Digital inputs : Dig.1 = Spare input (potential free input contact) Dig.2 = External alarm input (potential free input contact) Dig.3 = Spare input (potential free input contact) Analogue outputs : 2x /+1Vdc, Rbmin 1Kohm, programmable. Relay outputs : RY1 Extra relay (C/N/NC, 25Vac/1A not inductive) Possibilities extra relay (adjustable with parameter 2); P2= Fail safe alarm (normally CN is closed and CNC is closed when an alarm occurs) P2=1 Control alarm (normally CNC is closed and CN is closed when an alarm occurs) P2=2 Function Cooling P2=3 Function Heating P2=4 Function Dehumidifying P2=5 Function Humidifying The following relays have a central common; RY2 Dehumidifying (N, 25Vac/1A not inductive) RY3 Humidifying (N, 25Vac/1A not inductive) RY4 Heating (N, 25Vac/1A not inductive) RY5 Cooling (N/NC, 25Vac/1A not inductive) 2. Functional specifications The MC 785T KLIMA has the following control functions: cooling, heating, dehumidifying and humidifying. Further more the controller has an alarm relay, which is activated when the alarm levels are exceeded or a sensor is broken. The MC 785T KLIMA has two analogue P(I)outputs with a range from /+1Vdc. The function from these outputs are programmable as measuring signal, set point signal or a P(I) control for the cooling, heating, humidifying or dehumidifying. The controller has a digital inputs contact for an external alarm. The selection of the above mentioned settings is done through the Internal Parameters.
5 User manual Document nr. : 8626 Version : V1. MC 785TKLIMA Client : General Page : 5 from Control During normal operation the upper displays shows the measured temperature and measured relative humidity and the lower displays shows the temperature set point and the RH set point. Changing the temperature set point. Push the SET key next to the temperature set point display. The set point starts flashing. The set point can be changed with the UP and DWN key. By pushing the SET key once again, the set point shows continuously in the display. Changing of the RH set point. Push the SET key next to the RH set point display. The set point starts flashing and can be changed with the UP or DWN keys. By pressing the SET key again the set point appears continuously in the display. Resetting the alarm. As soon as an alarm situation occurs a failure message appears on the temperature display. With the RESET ALARM key, the alarm be reset. The error message remains in the display, till the cause of the failure is solved. External alarm input. If the external alarm input is closed, an alarm message appears in the display. The alarm relay is activated. By pressing the ALARM RESET key, the alarm relay can be reset. The error message remains in the display, until the external alarm input is opened again. Viewing and changing the time and day adjustments. By pushing the CLCK key, the current time will be visible. The time can be adjusted with the UP and DWN keys. With the N/FF key the day can be changed quickly. Starting and stopping from the adjusted week program. By pushing the START/STP key the program can be started or stoped. The LED above this key will be on if the program is running. The LED s 1 and 2 indicates which set point is active. The LED s (mo till su) above the measured value, are shown the current day. Be aware!! If the program is running only the active temperature and humidity set points can be changed by pushing the SET key simultaneously with the UP or DWN key.
6 User manual Document nr. : 8626 Version : V1. MC 785TKLIMA Client : General Page : 6 from 15 Programming the week program. To enter the programming mode from the week clock the PRG key should be pushed first and after that the CLCK key should also be pushed. n the CLCKdisplay (also RH display) appears the 1 e switch on time (monday LED ma is on) and the temperature (measured value) display turned off. n the temperature set point display (lower left) and the humidity set point display (lower right) are the belonging adjusted set points visible and also the LED s 1 besides the set points are on indicating which set point is shown. It is possible to jump to the next switch on time by pushing the PRG key. This will be the 2 nd time from the same day. After this the first switch on time of the next day can be adjusted. Etc. etc etc. Changing the switching time: The shown time can be adjusted by pushing the CLCK key simultaneously with the UP or DWN key. Changing temperature set point: The adjusted value can be changed by pushing the SET C key simultaneously with the UP or DWN key. Changing humidity set point: The adjusted value can be changed by pushing the SET key simultaneously with the UP or DWN key. With the PRG key the next adjustment can be made. After pushing the PRG key for the last time, the programming from the week clock will stop. An other way to stop the programming is, to touch no key for 3 seconds or pushing the N/FF key. Be aware!! Two switching times can be programmed for each day and each switch time has it own temperature set point and humidity set point. This makes a maximum of 14 switching times.
7 User manual Document nr. : 8626 Version : V1. MC 785TKLIMA Client : General Page : 7 from Programming internal parameters By pressing the PRG and RESET ALARM key at the same time for more than 5 seconds, the Internal Parameter menu is entered. n the display appears a P with a number behind it. With the UP or DWN key the required parameter is selected. The parameter can be read out by pushing the PRG key. By simultaneously pressing the PRG with the UP or DWN key, the value can be adjusted. After releasing the keys, the parameter number appears again in the display. If no key is pushed for 3 seconds, the display turns back to the normal operation mode. Parameter table. Nr Description Range Unit Default P 1 P 2 P 3 P 4 P 5 P 6 P 7 P 8 P 1 P 11 P 2 P 21 P 22 P 3 P 31 P 32 P 33 P 34 P 35 P 36 P 4 P 41 P 42 P 43 P 44 P 45 P 46 Differential cooling ffset cooling Differential heating ffset heating Differential dehumidifying ffset dehumidifying Proportional band humidifying (pulse/pause) Cycle time pulse/pause humidifying ffset temperature sensor ffset humidity sensor Function extra relay = fail safe alarm 1 = control alarm 2 = cooling 3 = heating 4 = dehumidifying 5 = humidifying 6 = fail safe alarm, not resettable with reset 7 = control alarm, not resettable with reset Differential extra relay ffset extra relay Minimum adjustable temperature set point Maximum adjustable temperature set point Read out above 1 C on whole degrees Read out below 1 C on whole degrees Minimum adjustable humidity set point Maximum adjustable humidity set point Humidity read out on whole percent Type temperature alarm = Non 1 = Absolute 2 = Relative Minimum alarm temperature Maximum alarm temperature Minimum alarm delay Maximum alarm delay Temperature control off at minimum alarm Temperature control off at maximum alarm,1..15, 15,..+15,,1..15, 15,..+15,,1..15, 15,..+15,,1..3, ,..+1, 15,..+15,..7,1..15, 15,..+15, 4,..+5, 4,..+5, = nee 1 = ja = nee 1 = ja,..1,,..1, = no 1 = yes..2 4,..+5, 4,..+5, = nee 1 = ja = nee 1 = ja C C C C Seconds C C, C, C C C C minutes minutes,5,,5, 1,, 5, 3,,,5, 4, +5, , +5,
8 User manual Document nr. : 8626 Version : V1. MC 785TKLIMA Client : General Page : 8 from 15 Nr Description Range Unit Default P 5 P 51 P 52 P 53 P 54 P 55 P 56 P 6 P 61 P 62 P 63 P 64 P 65 P 7 P 71 P 72 P 73 P 74 P 75 P 8 P 95 P 96 P 97 Type humidity alarm = non 1 = Absolute 2 = Relative Minimum alarm humidity Maximum alarm humidity Minimum alarm delay Maximum alarm delay Humidity control off at minimum alarm Humidity control off at maximum alarm Function analogue output 1 = Measured temperature 1 = Measured humidity 2 = Temperature set point 3 = Humidity set point 4 = P(I) cooling 5 = P(I) heating 6 = P(I) dehumidifying 7 = P(I) humidifying V out at 1V out at Proportional band 1 ffset proportional band 1 Integration time value 1 (999 = only P) Function analogue output 2 = Measured temperature 1 = Measured humidity 2 = Temperature set point 3 = Humidity set point 4 = P(I) cooling 5 = P(I) heating 6 = P(I) dehumidifying 7 = P(I) humidifying V out at 1V out at Proportional band 2 ffset proportional band 2 Integration time 2 (999 = only P) Control complete off during extern alarm Software version number Serial number Production date = no 1 = yes = no 1 = yes ,1..15, 15,..+15, ,1..15, 15,..+15, = no 1 = yes minutes minutes minutes minutes 1, 1, 4, +5, 1,, 999 year/wk 4, +5, 1,, 999
9 User manual Document nr. : 8626 Version : V1. MC 785TKLIMA Client : General Page : 9 from Working Relay outputs Working from cooling and heating. The cooling (RY5) switches on if the temperature is higher than the set point + offset cooling + differential cooling and switches off if the temperature is lower than the set point + offset cooling. The heating (RY4) switches on if the temperature is lower than the set point + offset heating differentie heating and switches off if the temperature is lower than the set point + offset heating. Working from the dehumidifying and humidifying The dehumidifying (RY2) switches if the RH is higher than the set point + offset dehumidifying + differential dehumidifying and switches off if the RH is lower than the set point + offset dehumidifying. The humidifying (RY3) switches on if the RH is lower than the set point + offset humidifying differential humidifying and switches off if the RH is lower than the set point + offset humidifying.
10 User manual Document nr. : 8626 Version : V1. MC 785TKLIMA Client : General Page : 1 from Sensor calibration With parameters P1 and P11 it is possible to calibrate the temperature and RH sensor. If the temperaturesensor shows,2 C to much, than the according sensoroffset must be lowered with,2 C. 7. Alarms If the extra relay is programmed as a fale safe alarm, than the relay is always energized and when an alarm occurs the relay will deenergized. Because of this there will also be an alarm if the supply voltage fails. If the extra relay is programmed as a control alarm, than the relay is always deenergized and when an alarm occurs the relay will energized. During alarm the alarm LED on the front flashes. Depending of the internal parameters the control will stop or continue. An alarm can be caused by: Temperature alarm : RH alarm : External alarm : Sensor failure : tl = Minimum temperature alarm thi = Maximum temperature alarm rl = Minimum RH alarm rhi = Maximum RH alarm F1 = External alarm E1 = Temperature sensor defect E2 = RH sensor defect The temperature alarm messages tl, thi, E1 and the external alarm message F1 will appear on the temperature display (upper left). The RHalarm messages rl, rhi and E2 will appear on the RHdisplay (upper right). By pushing the RESET ALARM key the alarm relay will be reset. The error message stays on the display as long as the alarm is there. Also the alarm LED stays flashing.
11 User manual Document nr. : 8626 Version : V1. MC 785TKLIMA Client : General Page : 11 from Front view Front view MC785T KLIMA wall mount. Drawing 1925 Front view MC785T KLIMA panel mount. Drawing
12 User manual Document nr. : 8626 Version : V1. MC 785TKLIMA Client : General Page : 12 from Connections Connections MC785T KLIMA wall mount. Drawing 1924
13 User manual Document nr. : 8626 Version : V1. MC 785TKLIMA Client : General Page : 13 from 15 Connections MC785T KLIMA wall mount. Drawing.99893
14 User manual Document nr. : 8626 Version : V1. MC 785TKLIMA Client : General Page : 14 from Dimensions Dimensions MC785KLIMA wall mount. Drawing 94142
15 User manual Document nr. : 8626 Version : V1. MC 785TKLIMA Client : General Page : 15 from 15 Dimensions MC785KLIMA wall mount. Drawing
EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual
EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING Manual Contents Introduction...3 Valve compatibility...3 Features...3 Application examples...3 Ordering...3 Operating the EKC 347...4-5
More information1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point
Medium - Control - System Franke & Haqenest GmbH Borngasse 1a * 04600 Altenburg Tel: 03447-499 313-0 Fax: 03447-499 313-6 email: info@mcs-gaswarnanlagen.de MCS User Guide MCS GasController Microprocessor
More informationANEMOMETER 4403-RF-BAT
ANEMO 4403 Radio impulsive output Anemometer - Wireless Robust wind speed sensor,extremely resistant and flexible, Suitable for many different application. Stainless steel bearings and high quality technical
More informationMulti-Gas-Controller MGC2
Page 1 Aug. 2018 Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology for continuous monitoring of the ambient air to detect toxic and combustible gases, refrigerants
More informationFan Coil Thermostat Controller Specification and Installation Instructions. Model TFH24F3XYZ2 Stand-alone with Internal Humidity Sensor
Model TFH24FXYZ2 Stand-alone with Internal Humidity Sensor Description The TFH24FXYZ2 is a fully configurable controller designed specifically for 2 pipe and 4 pipe fan coil applications. No additional
More informationINSTALLATION & USER MANUAL
INSTALLATION & USER MANUAL HC Digital Automatic Humidistat (Y3760) CONTROLS 506808-01 3/2016 Supersedes 6/2011 picture goes here THIS MANUAL MUST BE LEFT WITH THE HOMEOWNER FOR FUTURE REFERENCE NOTICE
More informationSafety & Installation Instructions
8400 Series Thermostats Safety & Installation Instructions READ AND SAVE THESE INSTRUCTIONS 61000652C 8400 Tstat Install.indd 1 10/13/09 11:08:56 AM Table of contents Installation Installation location
More informationRooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422
ºF / º C Rooftop Thermostat Controller Model TRT2422 Description The TRT2422 is a combination controller and thermostat with a built-in scheduler, which is designed for simple and accurate control of single
More informationST710-KHJV.03. Wiring diagram. Product description. Temperature controller. Order number
ST71-KHJV.3 Temperature controller Order number 921.8 Wiring diagram Product description The switching outputs of the thermal controller can be programmed as -two-point controller with alarm -three-point
More informationELECTRONIC HUMIDISTAT: H200
ELECTRONIC HUMIDISTAT: H00 ONE OR TWO STAGES DESCRIPTION The H00 series low voltage, microcomputerbased PI (proportional and integral) humidistats are designed for accurate humidification and/or dehumidification
More informationEC2-5x2 Series Condensing Unit Controllers
Technical Data The EC2-Series form a new generation of electronic controllers for refrigeration and air conditioning. The controllers combine in the small industry standard housing maximum functionality
More informationInstruction Manual PCS-400-XY. Pump Controller. Y=2: 4-20 ma Y=6: 0-10 VDC X=5: 1-5 VDC. 4 Pump Control Relays 1 Alarm Relay 1 Signal Fail
Manufacturers of Process Controls and Instrumentation Instruction Manual Model: Function: Input: PCS-400-XY Pump Controller X=2: 4-20 ma X=5: 1-5 VDC X=6: 0-10 VDC X=7: Output: Power: 4 Pump Control Relays
More informationCapacity controller EKC 331T REFRIGERATION AND AIR CONDITIONING. Manual
Capacity controller EKC 331T REFRIGERATION AND AIR CONDITIONING Manual Introduction Application The controller is used for capacity regulation of compressors or condensers in small refrigerating systems.
More informationSafety & Installation Instructions
Model 8476 Thermostat with Event-Based Air Cleaning Safety & Installation Instructions READ AND SAVE THESE INSTRUCTIONS Table of contents Installation Installation location recommendations... 3 Outdoor
More informationTC515 and TC600 Installation Manual. a Winters company
THERMOLINE TEMPERATURE CONTROLLERS TC515 and TC600 Installation Manual a Winters company Guarantee 12 months Congratulations on the purchase of this new product. Special care with the design, workmanship
More informationSafety & Installation Instructions
Model 8800 Universal Communicating Thermostat Safety & Installation Instructions READ AND SAVE THESE INSTRUCTIONS Table of contents Installation Installation location recommendations... 2 Thermostat mounting...
More informationTable of Contents. T538 Instruction Manual Rev # 6 June R6T538 June rtf E L Switchgear and Control Inc
Table of Contents Introduction...2 Mounting...2 Dimensions...2 Controls...3 Screen Displays...3 Screen Messages...4 Light Test...5 Control Power...5 Wiring...5 Inputs...7 Outputs...7 Programming...8 Technical
More informationER65-DRW Controller. Heating Applications. Product Bulletin. Heating Controller
PB_ER65-DRW_ 202 ER65-DRW Controller Heating Applications Product Bulletin The controller is a digital device for domestic or residential heating units. It covers water and air heating applications. All-in-one
More informationFan Coil Thermostat Controller Specification and Installation Instructions. Model TFHB24F3XYZ1 with External Humidity Sensor and BACnet Communication
Model TFHB24F3XYZ1 with External Humidity Sensor and BACnet Communication Description The TFHB24F3XYZ1 is a fully configurable controller designed specifically for 2 pipe and 4 pipe fan coil applications.
More informationProcess & TeMPerATUre UniversAl input DigiTAl MeTers
Process & TeMPerATUre UniversAl input DigiTAl MeTers nova PD56 series Thermocouple, rtd, & Process inputs Universal Power supply 1-24 va c Up to 3 Alarm relays retransmitting 4-2 ma output input Max/Min
More informationSafety & Installation Instructions
8400 Series Thermostats Safety & Installation Instructions READ AND SAVE THESE INSTRUCTIONS 61000652A 8400 Tstat Install.indd 1 7/23/09 2:20:45 PM Table of contents Installation Installation location recommendations...
More informationCTT8 TEMPERATURE MONITOR DEVICE
INSTRUCTION MANUAL IM302-U v2.3 CTT8 TEMPERATURE MONITOR DEVICE GENERALITY The device of control temperatures CTT8 is used in the control of electric machine, transformer, motor, etc. where it s possible
More information± 3% or better at 40%RH and 23ºC [73ºF] 0.8 mm 2 [18 AWG] minimum
Room Humidistat Features: Attractive modern look with large LD and backlight Icons driven information and 1 line of text External humidity sensor input Humidification and dehumidification indicator Multi
More informationELECTRONIC HUMIDISTAT: H270
ELECTRONIC HUMIDISTAT: H0 ONE OR TWO STAGES HUMIDITY SUPPLY OUTDOOR TEMPERATURE RESET DESCRIPTION The H0 series low voltage, microcomputerbased PI (proportional and integral) humidistats are designed for
More informationLuxPro Thermostats NEW MULTI-STAGE TOUCHSCREENS. Features & Programming. Mt. Laurel, NJ
NEW MULTI-STAGE TOUCHSCREENS Features & Programming NEW MULTI-STAGE TOUCHSCREENS PSPU721T 2H/1C PSPU732T 3H/2C 7 Day Programmable OR Non Programmable (Simple Mode) Dual Fuel Capable w/optional Outdoor
More informationInstructions for the fan motor control system, SILVER C
Instructions for the fan motor control system, SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units. The motor control system is
More informationTER Active Room Temperature Sensor (Controller),
Product sheet SN1.415 Type TER TER Active Room Temperature Sensors (Controllers) The TER active sensors are designed to detect temperature in the room spaces. The TER sensors have linear 0..10V signals
More informationStatic Pressure Control
The (model SPC-2) is a fully programmable controller that provides extensive flexibility for your curtain or awning control needs. The SPC-2 automatically controls the pressure in a room by operating a
More informationOxygen (O2) Single-Point Gas Detection System
Oxygen (O) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in oxygen (O) sensor, accepts one analog remote device such as a secondary gas sensor, temperature or humidity
More informationNitrogen Dioxide (NO2) Single-Point Gas Detection System
Nitrogen Dioxide (NO) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in nitrogen dioxide (NO)/diesel fume gas sensor, accepts one analog remote device such as a secondary
More informationPlug-n-Play Humidity Controller. IHC-200 User Manual. Version 1.3s. Inkbird Tech. Co., Ltd.
Plug-n-Play Humidity Controller IHC-200 User Manual Version 1.3s Copyright Copyright 2016 All rights reserved. No part of this document may be reproduced without prior written permission. Disclaimer Inkbird
More informationF4 Process Controller Installation and Operation Guide
F4 Process Controller Installation and Operation Guide 1.Introduction 1.1.Highlight Features Space saving, only 55mm panel depth required Higher sampling rate (1mS) results in better control performance
More informationINSTRUCTION MANUAL T-154. DOSSENA s.n.c. Via Federico Barbarossa s/n Cavenago di Adda tel Fax:
INSTRUCTION MANUAL T-154 DOSSENA s.n.c. Via Federico Barbarossa s/n 26824 Cavenago di Adda tel. +39 0371 44971 Fax: +39 0371 70202 http://www.dossena.it R.0 02/12/01 protection relays BT MT 220VAC-24VAC
More informationPROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS
PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS NOVA PD56 Series Thermocouple, RTD, & Process Inputs Universal Power Supply 1-24 VAC Up to 3 Alarm Relays Retransmitting 4-2 ma Output Input Max/Min
More informationBWAC Steuerung. Kochendwasser- Energiesparreinigung. Art.-Nr Version 1.0
Kochendwasser- Energiesparreinigung BWAC Steuerung Art.-Nr. 710300 Version 1.0 Lemmer-Fullwood GmbH Oberste Höhe 53797 Lohmar Tel.: +49(0)2206/9533 0 Fax: +49(0)2206/9533 60 info@lemmer-fullwood.de 1 Index
More informationMO n : 12JMC rév A
CTT8 MO n : rév A Page 2 / 18 MODIFICATIONS Rev. Description Date Checked by Approuved by Z Creation 2012/02/12 JMC LA A First issue 2012/02/14 JMC LA INDEX Page 3 / 18 GENERALITY 4 INTRODUCTION 4 ACCESSORIES
More informationWILLHI WH1436H Digital Humidity Controller Manual (NEW VERSION)
WILLHI WH1436H Digital Humidity Controller Manual (NEW VERSION) UPDATE: The outlet has been updated from a universal outlet to a standard U.S. outlet. The operation has been simplified for ease of use.
More informationTECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB
Summary 1 CONNECTIONS... 3 1.1 TEMPERATURE PROBES...3 1.2 LOW VOLTAGE DIGITAL INPUTS...3 1.3 LIVE DIGITAL INPUTS...4 1.4 RELAY OUTPUTS...5 2 POWER SUPPLY... 6 3 SERIAL CONNECTIONS... 6 4 SOFTWARE... 7
More informationFLOW CONTROLLER TYPE S/601
Checked Version Release date QA V4.2.6 F1 F2 EN 26.01.2012 Manual FLOW CONTROL FLOW CONTROLLER TYPE S/601 MODELS F1 AND F2 INTRODUCTION Thank you for using the S/601 flow and batch control series. This
More informationHD220 Dual Output Programmable Humidity Controller
AUBER INSTRUMENTS Instruction Manual WWW.AUBERINS.COM HD22 Dual Output mable Humidity Controller Version 1. (Sep, 216) 1. Oeriew This is a dual-output humidity controller with 8 programmable steps. It
More informationER65 - Mini Rack Controller Electronic Refrigeration Line
PB_ER65_ 00 ER65 - Mini Rack Controller Electronic Refrigeration Line Device is a multi-stage digital controller. It is typically applied to small refrigeration rack units piloting compressors or condenser
More informationHP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS
HP727S Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS 1. General Description 2. Specifications 3. Installation Instructions 4. Electrical Wiring 5. Instrument Wiring
More informationINSTRUCTION MANUAL P Heating and 2 Cooling with Humidification and De-humdification
REPLACEMENT COMPONENTS DIVISION CARRIER CORPORATION www.totaltouch.info Technical Support: 1-866-90TOUCH (1-866-908-6824) INSTRUCTION MANUAL P286-1400 3 Heating and 2 Cooling with Humidification and De-humdification
More informationRefrigeration and Air Conditioning Technical leaflet. Electronic controller EKC 201 and EKC 301
Refrigeration and Air Conditioning Technical leaflet Electronic controller EKC 201 and EKC 301 RC.5L.A1.02 RC.5L.A2.02 09-1998 Introduction EKC 201 and 301 are used for temperature control compressor control
More informationNetworkable Fan Coil Controller Specification and Installation Instructions
Controller Models EFCB10T-OE1 (24Vac / 0 relays) EFCB12T-OE1 (240Vac / 0 relays) EFCB10TU4-OE1 (24Vac / 4 relays) EFCB12TU2-OE1 (240Vac / 2 relays) EFCB12TU4-OE1 (240Vac / 4 relays) TFL Series Thermostat
More informationInstructions for the fan motor control system with integrated wiring terminals SILVER C
Instructions for the fan motor control system with integrated wiring terminals SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units.
More informationSCAN200E USER S MANUAL
SCAN200E USER S MANUAL Code No. 2071 1052 rev. 1.4 Code No. 2071 1052 Rev. 1.4 Page 2/16 SCAN200E User s Manual Foreword This manual is for SCAN200E Controller running software version 2.03 or later. We
More informationEOS. Instruction Manual. 120V High Amperage Digital Humidity Controller. Part #
EOS 120V High Amperage Digital Humidity Controller Instruction Manual Part # 702603 www.titancontrols.net 120V High Amperage Digital Humidity Controller Warnings and Cautions Factory Settings Eos 120V
More informationS/601 Controller Installation Manual
Checked Version Release date QA V4.6.5 PC1 EN 02.07.2012 2011 S/601 Controller Installation Manual FLOW CONTROL PC1 - Pump controller Introduction Thank you for using the S/601 flow, batch and pump control
More informationGMA4100-DP. Control Panel. Operation Manual. Worldwide Supplier of Gas Detection Solutions
Worldwide upplier of Gas Detection olutions GfG Instrumentation 1194 Oak Valley Drive, uite 20 Ann Arbor, MI 48108 800-959-0329 tel 734-769-1888 fax email: info@gfg-inc.com GMA4100-DP Control Panel Operation
More information02/11/2015
MIC48 With RS 485 link Part number 89422418 Heating and / or cooling function 2 independent alarms Load break detection 2 setpoint which can be selected remotely Manual / automatic power adjustment RS
More informationMICROFAN B.V. Industriestraat PH Horst P.O. Box AA Horst Developing, manufacturing and marketing of MICROFAN
Manual MIST TIME Version MIS 1.4-LP December 18, 2006 MICROFAN B.V. Industriestraat 23 5961 PH Horst P.O. Box 6022 5960 AA Horst Developing, manufacturing and marketing of MICROFAN The Netherlands computers,
More informationTemperature Controllers
Model TEC-4100 1/4 DIN Model TEC-4100 1/4 DIN Temperature Controller Ordering Code: Power Input BOX 1 4 = 90-250 VAC 5 = 11-26 VAC / VDC TEC-4100- Configurable for 4 Programmable Outputs and NEMA 4X/IP65
More informationAutomatic Lamp & Mat Heating Control
Automatic Lamp & Mat Heating Control PM-MCM100-01-240 8/02/7 Table of Contents Overview... 3 Components... 3 MicroZone MC100 Lamp and Mat Controller... 3 MicroZone MPM100 Power Modulator... 3 MicroZone
More informationController Specification Sheet
Controller Specification Sheet MC9550ABXXBX Proportional Inhibitor Dosing, Dual Conductivity Bleed Control, Dual Point ph Control, Redox Control of Oxidising Biocide and Secondary Biocide Dosing PULSAtrol
More informationAutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.
AutomationDirect 1/16 DIN Series Technical Support We strive to make our manuals the best in the industry. We rely on your feedback to let us know if we are reaching our goal. If you cannot find the solution
More informationTCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm
TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm General Description & Applications The TCA-9102 Series Temperature Controller with Alarm offers a versatile solution for a
More informationJDDT1 - Single Stage Digital Thermostat
JDDT1 - Single Stage Digital Thermostat CAUTION NOTICE: The thermostat must be installed by authorized professionals. It should be located in a place free of vibrations, impacts, and corrosive gases. SET
More informationB-40/B-41 Modulating Temperature Controller
INSTALLATION & OPERATING INSTRUCTIONS B-40/B-41 Modulating Temperature Controller For Raytherm Boilers & Water Heaters H2 514-4001 WH2 2100-4001 Catalog No. 5000.70 Effective: 12-21-11 Replaces: NEW P/N
More informationCDR-AL Room CO 2 Traffic Light Alarm Units and Sensors
Product sheet SN1.402 Type CDR-AL CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors CDR-AL sensors are designed to detect carbon dioxide concentration and temperature in the room spaces. The units
More informationST Wiring diagram. Product description. Standard temperature controller. Order number
ST64-31.10 Standard temperature controller Order number 900197.007 Old Id.Nr.: 386169 Wiring diagram Product description The controller ST64-31.10 was developed for simple thermostatic controls. The round
More informationEmerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING
Emerson Inspire 1HDEZ-1521 Installation Instructions Thermostat/Interface Equipment Control TROUBLESHOOTING FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL
More informationEasyTronic III MANUAL SERVICE
rev.6 EasyTronic III MANUAL SERVICE General characteristics: Power supply 24 Vac ±15% Max consumption at 24Vac 300mA Relay outputs 6 Maximum relay current 8 A res. Serial standard RS232 2 Serial standard
More informationSCHMIDT LED Measured Value Display MD Instructions for Use
SCHMIDT LED Measured Value Display MD 10.010 Instructions for Use Table of Contents 1 Important Information... 3 2 Application range... 4 3 Mounting instructions... 4 4 Electrical connection... 6 5 Signalizations...
More informationMCS 4000 Control Panel
Medium Control Systeme Franke & Hagenest GmbH Borngasse 1a * 04600 Altenburg Telefon : +49 3447 499 313 0 Telefax : +49 3447 499 313 6 E-Mail : info@mcs-gaswarnanlagen.de MCS Operation Manual MCS 4000
More informationEC3-X33 Stand-alone Superheat Controller Technical Data
Technical Data EC3-X33 is a stand-alone universal superheat controller for air conditioning, refrigeration and industrial applications such as chillers, industrial process cooling, rooftops, heat pumps,
More informationR1000 / R1040 / R1080
R1000 / R1040 / R1080 1 Zone Temperature Controller: Heat-only Heating-off-cooling Three-point stepping DIN-Format: 96mm x 96mm / 48mm x 96mm / 96mm x 48mm Description and operating manual ELOTECH Industrieelektronik
More informationTEMON 4-C. Doc. N MO-0368-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL. Microener- Copyright 2010 FW 2.1 Date Rev.
TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL Microener- Copyright 2010 FW 2.1 Date 01.12.2008 Rev. 0 1. Generality 3 2. Introduction 3 3. Accessories and Options 3 4. Installation 3 5. Connection
More informationMR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack
Master Catalog 125 Temperature Controls Section A Product/Technical Bulletin Issue Date 1098 MR4PMUHV Electronic Temperature/Defrost Control with Relay Pack The MR series temperature controls are designed
More informationQAF64.2-J QAF64.6-J. Frost detector. for use on the air side
s Frost detector for use on the air side QAF64.2-J QAF64.6-J With active capillary tube sensing element for acquiring the lowest temperature within a range of 0 15 C With startup function Operating voltage
More informationProgrammable Thermostat
Programmable Thermostat with Humidity Control Auto Changeover Dual Power 7-Day, 5-2-Day, or 5-1-1- Day Programmable Configurable for Multiple Systems Large Display with Backlight Selectable Fahrenheit
More informationTwo-Channel Gas Controller
Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously
More informationOwner s Manual. Walk-in Monitoring System 100B. Cooler is Better! TM. Used in UL Listed Door Panel Assemblies
REV. E Cooler is Better! TM Owner s Manual Walk-in Monitoring System 100B Used in UL Listed Door Panel Assemblies American Panel Corporation 5800 S.E. 78th Street, Ocala, Florida 34472-3412 Phone: (352)
More informationVAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1
Model TRO24T4XYZ1 Description The TRO24T4XYZ1 is a combination controller and thermostat. The VAV Thermostat Controller is designed for simple and accurate control of any variable air volume box in a number
More informationModel: RT310. Installation Manual
Model: RT310 Installation Manual Contents Product Compliance... 3 Safety Information... 3 Box Content... 3 Introduction... 4 Features... 5 Installation... 5 Button functions and keys... 7 Installer Mode...
More informationTHA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY Introduction.
More informationDew point set DS 400
set DS 400 Dew point set DS 400 for stationary dew point monitoring of refrigeration or adsorption dryers. The touch screen graphic display enables an intuitive operation and shows the progress of the
More informationUser Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs
User Manual Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs Models 89800-13 and 89800-14 THE STANDARD IN PRECISION MEASUREMENT Table of Contents
More informationTempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications
Instruction Manual Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications Manual PCT-3000 Revision 9/2014 The PCT-3000 series control console incorporates
More informationDIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173)
Evco S.p.A. Code 104K204E05 page 1/5 EVK204 Digital controller for ventilated refrigerating units, with HACCP and Energy Saving functions version 1.05 GB ENGLISH 1 PREPARATIONS 1.1 Important Please read
More informationTemperature controller for limitation for the discharge gas temperature EKC 319A REFRIGERATION AND AIR CONDITIONING. Manual
Temperature controller for limitation for the discharge gas temperature EKC 319A REFRIGERATION AND AIR CONDITIONING Manual Introduction Application The controller limits the pressure gas temperature in
More informationGMH 285 / GMH 285-BNC
GMH 285 GMH 285-BNC H69.0.01.6C-02 Operating Manual Pt1000 Precision Thermometer For exchangeable probes, with alarm as of version V1.0 GMH 285 / GMH 285-BNC GMH-GREISINGER GMH-GREISINGER WEEE-Reg.-Nr.
More informationOWNER S MANUAL Venstar Inc. 08/07
Digital Thermostat residential THERMOSTAT T1 800 7-DAY PROGRAMMABLE up to 3-heat & 2-cool HEAT COOL HEAT PUMP Control up to 3 Heat & 2 Cool Stages 3 Configurable Outputs Adjustable 2nd & 3rd Stage Timers
More informationInstruction Manual August sitrans CU 02
Instruction Manual August 2005 sitrans CU 02 Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment.
More informationTempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications
Instruction Manual Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications Manual PCT30006, Revision 9/20/2016 The PCT30006 control enclosure incorporates
More informationIntroduction. OM-THA2
Introduction. The OM-THA2 is a multi-function product that monitors Temperature, Humidity and Dew Point, provides alarms for out of range conditions, and continuously logs data. It consists of a base unit
More informationImportant Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.
1 P age Ezeio v9-120317 Eze Cloud Based Monitoring Systems. Created by Intech Instruments Ltd December 2014 Important Supplementary Manual to the main Ezeio manual. Ezeio Controller and the 2400-A16 input
More informationHEAT HEAT HEAT COOL COOL PUMP OWNER S MANUAL 7-DAY TOTALINE
OWNER S MANUAL COMMERCIAL THERMOSTAT P/N P374-2800 I 2 : 0 0 Su AUTO Pm 74 COOL 7 2 HEAT T O T A L I N E HEAT COOL 7-DAY HEAT PUMP PROGRAMMABLE DIGITAL THERMOSTAT 3 Configurable Outputs Control up to 2
More informationVM-702B ABSOLUTE VIBRATION MONITOR MODULE Page 1 of 5
Page 1 of 5 No entry if additional Model Code / Additional Spec. Code ( spec. code is not specified. ) VM-702B /ALY /NB1 /CS1 /CS2 /TRP /TB Analysis Function Non-incendive * 1 Monitor Function Analysis
More informationCMT MANUAL 6. NMC SENSORS
CMT MANUAL 6. NMC SENSORS TABLE OF CONTENTS INDEMNITY... 5 DOCUMENT INFORMATION... 5 ACKNOWLEDGEMENTS... 5 6.1 INTRODUCTION... 6 6.2 TEMPERATURE AND HUMIDITY SENSORS... 7 6.2.1. TEMPERATURE SENSOR... 7
More informationAnalog Room Pressure Monitor RPC Series
Description The Room Pressure Monitor is used to measure differential pressure in the range of 0.125 to 1"wc or 30 to 250 Pa. It combines precision high sensitivity silicon sensing capabilities and the
More informationMF-PFA ver 3.x. Micaflex PFA ver 3. Pressure- and Flow transmitter with alarmfunction. Installation- & Operation manual [Dok. id: mi-303gb_180528]
Installation- & Operation manual [Dok. id: mi-303gb_180528] Micaflex PFA ver 3. Pressure- and Flow transmitter with alarmfunction and control output MF-PFA ver 3.x NOTE! Read through the entire manual
More informationDew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510
Dew point monitoring DS 400 for stationary dew point monitoring of refrigeration or desiccant driers. The touch screen graphic display enables an intuitive operation and shows the progress of the measured
More informationDSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE
DSGH Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE Revision History Revision History Version of manual Description Date 1.0 Initial release 051025 1.1
More informationEWCM 900/S rel. 5/2000 ing
cod. 9IS40178 EWCM 900/S rel. 5/2000 ing compressors and fans manager WHAT IT IS The EWCM 900(/S) is a series of controllers designed specifically for the control of a machine room in a refrigeration system.
More informationDFM. flow pressure temperature MULTI PARAMETER DIGITAL MASS FLOW METERS. Totalizer. Interface
Multi Parameter flow meters provide accurate data on three different fluid parameters: flow pressure temperature The flow rate can be displayed in volumetric flow or mass flow engineering units for standard
More information02/11/2015
CTH 46 - CTD 43 / 46 CTD 46 Part number 89422108 CTH 46 Heating / cooling function Measurement and setpoint display CTD 43 Heating or cooling function Measurement display Measurement deviation display-setpoint
More informationXSD Dry Cabinet. Outstanding performance. The XSD series has an outstanding performance for drying moisture sensitive components and pcb s.
XSD 1402-54 Dry Cabinet Outstanding performance The XSD series has an outstanding performance for drying moisture sensitive components and pcb s. The dynamic drying unit of the 5000 series reaches very
More informationRC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control
O M N I S T A T ELECTRONIC COMMUNICATING THERMOSTAT Installation Manual RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control Document Number 13I00-5 November, 1997 CONTENTS
More informationSAS908WHB-3-RF/B WIRELESS THERMOSTAT
SAS908WHB-3-RF/B WIRELESS THERMOSTAT Installation and operation instructions 908WHB-3-RF/B can replace most common residential thermostat and is designed to be used with electric, gas or oil heating control
More information