Central Battery & Central Monitoring System

Size: px
Start display at page:

Download "Central Battery & Central Monitoring System"

Transcription

1 We hereby certify that Quality Management System of 1081 Budapest, Kun utca 4. fszt. 7. complies with requirements of in the following scope: Wholesale, retail trade and export of security products and systems. Manufacture of emergency lighting, siren and power supply units Certificate No.: Date: Valid until: EAC code: 29 Bujtás Gyula CEO Budaörs, Tanúsítjuk, hogy az 1081 Budapest, Kun utca 4. fszt. 7. min ségirányítási rendszere megfelel az szabvány követelményeinek, a következ alkalmazási területeken: Biztonságtechnikai termékek és rendszerek kis- és nagykereskedelme, valamint exportja. Vészvilágítás, sziréna és tápegység gyártása A tanúsítvány száma: Dátum: Érvényes: EA kód: 29 Bujtás Gyula vezérigazgató Budaörs, Page Bottom See General Information for Emergency Lighting and Power Equipment EML LIGHTING KFT KUN UTCA 4 FSZT BUDAPEST, HUNGARY E Trademark and/or Tradename: Addressable Graphical Symbol Sign (Running Man), Model(s) EML-6014, EML-6017 Addressable graphical symbol signs, Running man, Model(s) EML-414, EML-515 Addressable unit equipment, Model(s) EML-313F, EML-313R, EML-4014/F, EML-4014/R, EML-6016, EML-613, EML-616, EML-813, EML-816 Emergency Lighting System Control Panel, Model(s) EML-601, EML-602, EML-603, EML-604, EML-605, EML-606 Emergency lighting system control panels, Model(s) EML-100, EML-200, EML-300, EML-400 Emergency lighting system control panels, AC controls, Model(s) EML-AC Emergency lighting system control panels, Addressable modules, Model(s) EML-AM Last Updated on Questions? Print this page Terms of Use Page Top 2018 UL LLC The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: " 2018 UL LLC". Page Bottom See General Information for Exit Fixtures EML LIGHTING KFT KUN UTCA 4 FSZT BUDAPEST, HUNGARY E Trademark and/or Tradename: Addressable Graphical Symbol Light (Running Man), Model(s) EML-6024 Last Updated on Questions? Print this page Terms of Use Page Top 2018 UL LLC The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: " 2018 UL LLC". Central Battery & Central Monitoring System Company Profile EML Lighting Ltd. Safety products and exit luminaries are designed, manufactured and supplied in both conventional and addressed systems. The addressed systems offer a number of advantages; after installation and commissioning, the systems can be maintained cost-effectively. The unique addressing of the lights provides easy supervision for maintenance and all the necessary information regarding the functioning are shown on the control panel s LCD. The product range includes of EML lights with Central Battery (CB), EML lights with Main Battery (MB), EML accessories (Addressing Module, Control Module, Body suspending Hangers, Interfaces for logical settings), Main Units (Control Panels). The products have been manufactured, mastered over the years of acquired knowledge base and perfected to comply to their applications under the approvals of related international standards. Today s events around the world make it increasingly necessary to have security systems at all times, accuracy and immediate response to life-threatening events are basic needs. In the event of a simple power outrage or fire, buildings must be emptied in the shortest term possible and must be eliminated. It is vitally important to make the escape safe, fast, and secure with exit signs visible from any point in the place to show the passageways. The Central Battery, Main Battery and control panels are interfaced at high technological essence to keep the sign on at all times to assist evacuation of persons in short time. CERTIFICATE TANÚSÍTVÁNY FTBR.E Emergency Lighting and Power Equipment Emergency Lighting and Power Equipment FWBO.E Exit Fixtures Exit Fixtures EML Lighting Kft. EML Lighting Kft. BS EN ISO 9001:2015 MSZ EN ISO 9001: Techno Fire & Safety Co. LLC

2 The main unit (control panel) directly, or through a sub center controls supervises the operation of the luminaries connected to the panel system. The control Panel is designed to checks the presence of the working supply voltage in the split circuit of the building with the help of the control modules incorporated in the control panel. When required as per the safety requirements, the control panel switches the lighting units to emergency mode. CENTRAL MONITORING SYSTEM EML Addressable Emergency Lighting Control Panel EML-100, EML-200, EML-300, EML-400 (MB/CB) Number of devices Voltage Range Communication Network Luminaire control Web server function Store events Gateway management Software Menu Display Output Ingress protection Certificates 99/198/297/396 pcs. of devices (99 devices per line) V AC-DC 50-60Hz, 700W/line V AC line communication, UDP, MODBUS communication TCP/IP network The luminaires can be controlled individually Status and event display on the website 2000 events / control panel 254 panels / system Graphic software Multi-language menu, Touch monitor 3,5 4 Relay output IP44 CE, UL EML brand main unit controls the operation of the luminaries in CB system. The control units come in two versions viz., according to UL or DIN standards respectively. They work in both AC and DC modes and as well from 120V to 240V supply. The units are designed to adapt to any UPS (not only EML s central battery) for Power input source. They can handle up to a maximum of 594 addressed devices, or as per DIN standard, 18x20 devices; the load consumed is maximum 12kW/unit. The device can be set easily with the help of its 7 display. CENTRAL BATTERY SYSTEM EML Addressable Emergency Lighting Control Panel EML-601, EML-602, EML-603, EML-604, EML-605, EML-606 Number of devices Voltage Range Communication Network Luminaire control Web server function Store events Gateway management Software Menu Display Output Ingress protection Certificates 99/198/297/396/495/594 pcs. of devices (99 devices / line) or as per DIN 18 lines, (20 devices / line) V AC-DC Hz, 2000W/line V AC line communications, UDP, MODBUS, FIRE ALARM (option) RS485 The luminaires can be controlled individually Status and event display on the website 2000 events / control panel 64 panels / system Graphic software Multi-language menu, Touch monitor 7" 4 Relay output IP20 CE, UL Techno Fire & Safety Co. LLC 13

3 EML-613 /slave/mb OR EML-613 / slave/cb Type EML-616 / slave/mb OR EML-616 / slave/cb Type EML-813 / slave/mb OR EML-813 / slave/cb Mounting : Concealable Type EML-816 / slave/mb OR EML-816/ slave/cb Mounting : Concealable EML-515 / slave/mb OR EML-515 / slave/cb IP Rating : IP42 Viewing Dist. 25Mtr. EML-414 / slave/mb OR EML-414 / slave/cb / Concealable IP Rating : IP42 EML-6014 / slave/mb OR EML-6014 / slave/cb Mounting : Ceiling EML-6017 / slave/mb OR EML-6017 / slave/cb Mounting : Sidewall EML-6016 / slave/mb OR EML-6016 / slave/cb Mounting : Sidewall / Ceiling 14 Techno Fire & Safety Co. LLC

4 EM L-4014 R/F/slave/MB OR EM L-4014 R/F/slave/CB Mounting : Recessed Light : 4 I Rating : IPA Main Supply : V AC 50-60hz EML-313 R/F/slave/MB OR EML-313 R/F/slave/CB Mounting : Ceiling Surface / Recessed IP Rating : IP20 EML SH 1 (Interface for 99 pcs luminaires) EML-AC (230V/PF control module) Input (for phase monitoring) Current drain Power Max device/panel Closing resistor (active with jumper) Connection (to panel) RS bus max distance Cable Battery (powering the device) : AC 230V / pot free power control : 11mA : 2.5VA : 32 pcs (uniquely addressed)q : For closing the RS485 line on the last AC control : RS485 : 1200m (without repeat) : Should use twisted pair cabling : 6V 80mAh EML - SLAVE (Communication unit for slave/cb, slave/mb, slave/con/mb, slave/con/cb) EML-AM (MB/CB) Addressing module Input current Max capacity Ambient temperature Terminals Functions : AC/DC V60/50Hz : 100W : 100C-300C : 2.5 m2 single wire or 1.5 m2 stranded and soldered : Phase monitoring Battery status monitoring - Addressed device status monitoring EML FUG2 / FUG5 (Light body suspensory system, 1.5 mm stainless steel, with eyelets, 2 m / 5 m long) Techno Fire & Safety Co. LLC 15

5 Schematic for addressable emergency and exit lights with main battery. Recommended cable diameters depending on distance are 3x1.5 mm2 or 3x2.5 mm2 Schematic for addressable emergency and exit showing lights with central battery. Recommended cable diameters depending on distance are 3x1.5 mm2 or 3x2.5 mm2 16 Techno Fire & Safety Co. LLC

front cover Techno Fire & Safety Co. LLC

front cover Techno Fire & Safety Co. LLC front cover Techno Fire & Safety Co. LLC 1 Our Global Partners Class A Certified Company for Annual Maintenance Contract UAE Approvals 2 Techno Fire & Safety Co. LLC Company Profile We, M/s. Techno Fire

More information

AMCXC.S CENTRAL AND MONITORING STATION BURGLAR ALARM SYSTEM UNITS

AMCXC.S CENTRAL AND MONITORING STATION BURGLAR ALARM SYSTEM UNITS Page 1 of 5 AMCXC.S4019 - CENTRAL AND MONITORING STATION BURGLAR ALARM SYSTEM UNITS Central and Monitoring Station Burglar Alarm System Units See General Information for Central and Monitoring Station

More information

Advanced FireAlarm Panel 1-4Loop

Advanced FireAlarm Panel 1-4Loop Advanced FireAlarm Panel 1-4Loop Advanced Technologies Advanced Electronics Ltd IP Gateway Monitoring and interrogation via the internet Password protected multiple user permissions Event notification

More information

ZERTI ~CERTIFICAJE. Certificate holder. Product tested. Manufacturer. Type designation. Codes and standards forming the basis of testing

ZERTI ~CERTIFICAJE. Certificate holder. Product tested. Manufacturer. Type designation. Codes and standards forming the basis of testing ZERTI ~CERTIFICAJE t Product tested Active pto-electronic Protective Device responsive to Diffuse Reflectio (AOPDDR), Laser Scanner Certificate holder OMRON Scientific Technologies, Inc. 6550 Dumbarton

More information

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL PRODUCT Specification FEATURES Designed To Meet The Requirements Of EN54 Expandable From 1 To 5 Loops As Standard A Variety Of Networking Options

More information

Room Temperature Sensors

Room Temperature Sensors 1 749 1749P01 QAA201 Symaro Room Temperature Sensors QAA201 Active sensors for acquiring the room temperature Operating voltage AC 24 V or DC 135 35 V Signal output DC 010 V or 420 ma Use In heating, ventilation

More information

ModBus DE-1 INSTALLATION AND USER MANUAL

ModBus DE-1 INSTALLATION AND USER MANUAL ModBus DE-1 INSTALLATION AND USER MANUAL INTESIS Software, SL Distributed by DURAN ELECTRONICA S.L Tomás Bretón 50 28045 MADRID, España duran@duranelectronica.com www.duranelectronica.com 2 2010 DURAN

More information

Reliably Advanced Extinguishing Control

Reliably Advanced Extinguishing Control Reliably Advanced Extinguishing Control 14 years. 60 countries. Still Advanced. We re the same people, with the same commitment to excellence and customer satisfaction and now we have a brand that reflects

More information

UL Online Certifications Directory

UL Online Certifications Directory UL Online Certifications Directory OCD Home Quick Guide Contact Us UL.com NBSX.BP6524 Household Burglar Alarm System Units Page Bottom Household Burglar Alarm System Units See General Information for Household

More information

OMRON SCIENTIFIC TECHNOLOGIES INCORPORATED ECDeclaration ofconformity

OMRON SCIENTIFIC TECHNOLOGIES INCORPORATED ECDeclaration ofconformity omron 9ti OMRON SCIENTIFIC TECHNOLOGIES INCORPORATED ECDeclaration ofconformity OMRON Scientific Technologies Incorporated (at 6550 Dumbarton Circle, Fremont, CA 94555-3605, U.S.A.), hereby declares that

More information

NBSXC.S4019 Household Burglar Alarm System Units. Household Burglar Alarm System Units

NBSXC.S4019 Household Burglar Alarm System Units. Household Burglar Alarm System Units Online Directories OD Home Contact Us ULC.ca NBSXC.S4019 Household Burglar Alarm System Units Page Bottom Household Burglar Alarm System Units See General Information for Household Burglar Alarm System

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET Wed : www.saenchotesei.com WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 920 - Wall, 19 Rack or Panel Mounting Units - 110/230V 50/60Hz AC operation - 250 Addressable

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET Control Systems Transmitters Sensors Accessories Wall, 19 Rack or Panel Mounting Units 110/230V 50/60Hz AC operation 250 Addressable devices as: Relays, 4-20 Inputs or Gas Detectors

More information

AE-CU Adaptive Escape Routing for Emergency Lighting. From static to adaptive escape routing

AE-CU Adaptive Escape Routing for Emergency Lighting. From static to adaptive escape routing AE-CU Adaptive Escape Routing for Emergency Lighting From static to adaptive escape routing We make what matters work.* * At Eaton, we believe that power is a fundamental part of just about everything

More information

CV-350 TCP/IP Access Control System. System Overview

CV-350 TCP/IP Access Control System. System Overview CV-350 TCP/IP Access Control System System Overview July 2015 Open Product Access Camden delivers the power of advanced IP access control differently than our competitors! - All product sales exclusively

More information

AMCXC.S7513 Central and Monitoring Station Burglar Alarm System Units. Central and Monitoring Station Burglar Alarm System Units

AMCXC.S7513 Central and Monitoring Station Burglar Alarm System Units. Central and Monitoring Station Burglar Alarm System Units Online Directories Quick Guide OD Home Contact Us ULC.ca AMCXC.S7513 Central and Monitoring Station Burglar Alarm System Units Page Bottom Central and Monitoring Station Burglar Alarm System Units See

More information

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS GENERAL INFORMATION Please read these instructions and keep them in a safe place. These instructions must

More information

Controllers. Centralization of Access Control Devices Made Easy. Installer Guide

Controllers. Centralization of Access Control Devices Made Easy. Installer Guide Controllers Centralization of Access Control Devices Made Easy Installer Guide CONTENTS 1 INTRODUCTION 3 The Overview of Hardware 5 The Overview of Installation & Communications 7 Installations with door

More information

ELECTRONIC SOUNDER STROBE Model : AVD-C407

ELECTRONIC SOUNDER STROBE Model : AVD-C407 ELECTRONIC SOUNDER STROBE Model : AVD-C407 MULTRON range of combination Electronic Sounders with Strobe Lights are designed to complement our Fire Alarm products both technically and aesthetically as an

More information

HTC-915-CONT. Heat-Trace Control system

HTC-915-CONT. Heat-Trace Control system Heat-Trace Control system Product overview The Raychem HTC-915 system is a compact, full-featured microprocessor-based single-point heat-trace controller. The HTC-915-CONT provides control and monitoring

More information

Specification for On-Line UPS Battery Monitoring and Data Management System

Specification for On-Line UPS Battery Monitoring and Data Management System 1 Scope This specification defines the minimum requirements for a predictive on-line Battery Monitoring BMDMS with test, analysis, and remote monitoring control capabilities. Unless noted otherwise, the

More information

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC Take Fire Protection to the Next Level Fire Products from DSC AFD2000 Addressable Fire Control Panel Series Provides Maximum Flexibility The new AFD2000 is a completely programmable series of addressable,

More information

DESCRIPTION. 42 mm. 125 mm

DESCRIPTION. 42 mm. 125 mm RMM2-DI TRACE-HEATING REMOTE MONITORING MODULE FOR DIGITAL INPUTS DESCRIPTION 125 mm 60 mm The Remote Monitoring Module for Digital Inputs (RMM2-DI) provides the capability for the Raychem NGC controller

More information

Why Hart XL Aspirating Smoke Detection?

Why Hart XL Aspirating Smoke Detection? HART XL Why Hart XL Aspirating Smoke Detection? Earliest detection to enable business continuity Extra time is required for safe evacuation Unnecessary suppression release must be avoided Smoke is difficult

More information

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM Card Rack Modules CABLE DUCT MAIN SWITCH 800 mm USER INTERFACE TERMINAL PRODUCT OVERVIEW The nvent

More information

Fire control panel detect 3004 plus and accessories

Fire control panel detect 3004 plus and accessories Fire control panel detect 3004 and accessories The modular fire alarm panel detect 3004 is the basic version of a broad product portfolio of the system detect 3000. Up to 20 fire control panels can be

More information

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING Manual Contents Introduction...3 Valve compatibility...3 Features...3 Application examples...3 Ordering...3 Operating the EKC 347...4-5

More information

Danfoss gas detection Controller unit

Danfoss gas detection Controller unit Data sheet Danfoss gas detection Controller unit The gas detection Controller Unit is used for a centralized monitoring and warning of hazardous gas concentrations. The input signals for the controller

More information

I/A Series 716C 1/16 DIN Temperature Controller

I/A Series 716C 1/16 DIN Temperature Controller Product Specifications I/A Series 716C 1/16 DIN Temperature Controller PSS 2C-1B5 A The Foxboro 716C is a powerful compact, 1/16 DIN, microprocessor-based temperature controller that offers a variety of

More information

Corrigo E. Second generation which contains all applications and languages

Corrigo E. Second generation which contains all applications and languages revision 05 2009 Corrigo E Second generation which contains all applications and languages The controllers in the Corrigo E series are intended for applications within heating, boiler and ventilation control

More information

TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2

TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2 FEATURES: Closed Loop Design (Class A Wiring) Microprocessor Based System Intelligent Distributed System Structure Quick Response Time Fire Alarm in

More information

The EN54 Part 2 & 4 Fire System

The EN54 Part 2 & 4 Fire System Scope of work: To design, supply, install and commission an Analogue Addressable Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54

More information

Reliably Advanced Extinguishing Control

Reliably Advanced Extinguishing Control Reliably Advanced Extinguishing Control The Best Choice for Asset Protection What suppression and extinguishant control panel would you choose to protect the literary collection of an entire nation? 47

More information

Detection, Protection, Innovation

Detection, Protection, Innovation MX3 CONTROLLER MX 3 CONTROLLER Analog and digital controller or 8 lines / 6 to 32 s max Highly versatile controller SIL reliability CERTIFICATIONS Detection, Protection, Innovation Oldham SAS has more

More information

EMERGENCY LIGHTING SYSTEM

EMERGENCY LIGHTING SYSTEM EMERGENCY LIGHTING SYSTEM 1300 INCITE www.incitefire.com.au PRODUCT CATALOGUE EXIT-EMERGENCY LIGHTING AN EXTRA LOW VOLTAGE EXIT & EMERGENCY LIGHTING SYSTEM FIREscape is a revolutionary emergency lighting

More information

Constant climate chambers

Constant climate chambers KBF series (E5.2) Constant climate chambers Constant climate chambers The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climatic conditions.

More information

Technical Speci fications 220V AC 50Hz or 110V AC 60Hz Accessories operational voltage. 2x 12V / 7Ah sealed lead acid gel batteries

Technical Speci fications 220V AC 50Hz or 110V AC 60Hz Accessories operational voltage. 2x 12V / 7Ah sealed lead acid gel batteries EN54 General Speci fications Advanced analog fire alarm control panel for small or medium installations. Number of zones: 4, 8, 12, 16, 20 or 24. Maximum number of detectors per zone 20. Two wire zone

More information

Med Touch Master Alarm

Med Touch Master Alarm Submittal Data Sheet Features The Powerex Med Touch Master Alarm Panel monitors and displays normal and alarm conditions from up to 128 remote medical gas source signals and provides alarm conditions as

More information

UNC100 Integra Manual

UNC100 Integra Manual UNC100 Integra Manual New Generation Building Security July 30, 2014 V1.2 Copyright Notice Copyright 1995-2014 by All rights reserved Worldwide. Printed in Canada. This publication has been provided pursuant

More information

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual Revision 6/01.17 Contents 1. Introduction... 6 2. Terminology... 6 3. Function... 8 4. Technical data... 8 4.1. Physical configuration...

More information

On the job around the clock 24/7: Fire detection systems

On the job around the clock 24/7: Fire detection systems On the job around the clock 24/7: Fire detection systems Version 02.2010 Version: 02.2010 Product catalogue Fire detection systems This product catalogue is intended for sales purposes only. For planning,

More information

Tri-Tech Medical Inc.

Tri-Tech Medical Inc. Submittal Data Sheet Project Information Project Number Approval Features The Master Alarm Panel conversion kits are designed to upgrade or retro-fit existing panels produced by several major brands. The

More information

Danfoss gas detection units

Danfoss gas detection units Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning

More information

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) IRDH375_D00124_01_D_XXEN/07.2018 Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Product

More information

Alarm module for leak detection with webserver

Alarm module for leak detection with webserver This instruction document consists of 2 parts : one part about the assembly of the components and one part about configuration and starting-up of the system. The assembly is done by the qualified installer

More information

IndigoVision Alarm Panel. User Guide

IndigoVision Alarm Panel. User Guide IndigoVision Alarm Panel User Guide THIS MANUAL WAS CREATED ON 2/21/2017. DOCUMENT ID: IU-AP-MAN002-4 Legal considerations LAWS THAT CAN VARY FROM COUNTRY TO COUNTRY MAY PROHIBIT CAMERA SURVEILLANCE. PLEASE

More information

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Process & TeMPerATUre UniversAl input DigiTAl MeTers Process & TeMPerATUre UniversAl input DigiTAl MeTers nova PD56 series Thermocouple, rtd, & Process inputs Universal Power supply 1-24 va c Up to 3 Alarm relays retransmitting 4-2 ma output input Max/Min

More information

DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS. A4741 / Rev.1

DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS.  A4741 / Rev.1 DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS User Manual and Menu Map A4741 / Rev.1 www.entes.com.tr ATTENTION -Disconnect all power before connecting the device. -Don t remove

More information

RAYCHEM NGC-30 COMPONENTS

RAYCHEM NGC-30 COMPONENTS PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM PRODUCT OVERVIEW CABLE DUCT Card Rack Modules TERMINAL STRIP PLINTH MAIN SWITCH 800 mm USER INTERFACE

More information

In installation with more doors, up to 64 central units can be used together, allowing installations of up to 2,048 doors. RECEPTION CAR PARK

In installation with more doors, up to 64 central units can be used together, allowing installations of up to 2,048 doors. RECEPTION CAR PARK Access Control CENTRALISED CAC The CAC (centralised access control ) allows complex installations with several accesses and additional functions. It also makes it possible to integrate other services:

More information

FLAME ITEM PART NO CLIENT REF. NO. DESCRIPTION DESIGNATION MANUFACTURER CLASS UL FILE NO.

FLAME ITEM PART NO CLIENT REF. NO. DESCRIPTION DESIGNATION MANUFACTURER CLASS UL FILE NO. BOM FOR UL CERTIFICATE NUMBER Model Name: CLASSIC TOWER LIGHT Documents Number 122-EI04 This is to certify that the above product was supplied to SUZO Internation (NL) BV Revision A2 are made of the followings,

More information

Satchwell. DC1100 Energy Controller SELF CONFIGURING OPTIMISER/COMPENSATOR WITH BOILER SEQUENCE AND HWS CONTROL FEATURES

Satchwell. DC1100 Energy Controller SELF CONFIGURING OPTIMISER/COMPENSATOR WITH BOILER SEQUENCE AND HWS CONTROL FEATURES Satchwell DC1100 Energy Controller SELF CONFIGURING OPTIMISER/COMPENSATOR WITH BOILER SEQUENCE AND HWS CONTROL DC1100 Specification No. 04-03-105 The DC1100 energy controller is a self configuring optimiser/

More information

CAN unit for Analog Sensors

CAN unit for Analog Sensors CAN unit for Analog Sensors Didactum`s Monitoring Systems have many uses: Monitoring of wring closets and server room environments Remote monitoring of technical rooms in branch offices Monitoring of power

More information

FIRElux Emergency Lighting

FIRElux Emergency Lighting ABC a FIRElux Emergency Lighting Safety In All Enviroments FIRElux is a completely new emergency lighting system. The rapid development of LED technology has made it possible to implement emergency lighting

More information

General Routing Interface

General Routing Interface General Routing Interface Features The General Routing Interface Card is an optional module to provide Fire and Fault Routing Outputs compliant with BSEN54-2: 1998 Clauses 7.9 and 8.9 and BS5839-1: 2002.

More information

EMERGENCY LIGHT SERIES

EMERGENCY LIGHT SERIES ASENWARE EMERGENCY LIGHT SERIES 1 / 38 EMERGENCY LIGHT SERIES 1 About ASENWARE was set up at 2005 in UK. After over 10 years very fast developing, we keep the high investment for R&D and international

More information

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing Control Panels Control Panels for Commercial Applications Control panels provide the central processing and logic for an integrated system. In a typical system, there are four major functions: inputs,

More information

Process Alarm Module RTA 421

Process Alarm Module RTA 421 Technical Information TI 074R/24/ae Process Alarm Module RTA 421 Alarm module and power supply for monitoring current or voltage signals Application Areas Plant and machine construction Panel builders

More information

HRX3000. Technical Manual

HRX3000. Technical Manual HRX3000 Technical Manual Contents: Specification...2 Connectors...3 Power (J21)...3 RS-485 Network Connectors (J6 and J7)...4 RS-232 to PC (J8)...5 Printer and Fire Alarm Panel (J19)...6 TCP/IP...8 Modem

More information

AirFlow Sensor for Dry Contact connection

AirFlow Sensor for Dry Contact connection Didactum`s IP-based monitoring devices have many uses: Monitoring of wiring closets and server room environments Remote monitoring of technical rooms in branch offices Monitoring of power supply systems

More information

600 Range Dialer Installation Manual. Version 1.0

600 Range Dialer Installation Manual. Version 1.0 600 Range Dialer Installation Manual Version 1.0 The information contained is supplied without liability for any errors or omissions. No part may be reproduced or used except as authorised by contract

More information

Multi-Gas-Controller MGC2

Multi-Gas-Controller MGC2 Page 1 Aug. 2018 Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology for continuous monitoring of the ambient air to detect toxic and combustible gases, refrigerants

More information

The system should also be capable of recording events automatically on any compatible DVR and should be able to retrieve recordings based on events.

The system should also be capable of recording events automatically on any compatible DVR and should be able to retrieve recordings based on events. 0BThe System The Security Management System should be capable of Controlling and Monitoring Access through the doors, Monitor and control Inputs and Outputs, include an Integrated Video Badging, Integrate

More information

Networked Access Control Panel. Installation Guide

Networked Access Control Panel. Installation Guide XP2M Networked Access Control Panel V1.0X Installation Guide X P 2 M A C C E S S C O N T R O L S Y S T E M Installation Guide Document Ref: PLAN XP2M Installation Guide V4(G)2010 Access Control Services

More information

Panel Mounted Fault Annunciator Series

Panel Mounted Fault Annunciator Series Panel Mounted Fault Annunciator Series BSM / USM Panel-mounted fault annunciator Annunciators for panel mounting with,,,, 0 and signal inputs Storage of the last state of inputs and sequence in the case

More information

Control System Structure

Control System Structure Control System Structure Centralized Controller Wireless Controller Centralized Controller Wired Controller BMS User Friendly Management Control Solution Integrated Management Building Management Convenient

More information

Intelligent Addressable Fire Alarm System

Intelligent Addressable Fire Alarm System Intelligent Addressable Fire Alarm System Company Profile The Company established in 2003, is manufacturing security system devices with the brand name DEKON Security Technologies for the exclusivity of

More information

The EN54 Part 2, 4 and 13 Fire System

The EN54 Part 2, 4 and 13 Fire System Scope of work: To design, supply, install and commission an Analogue Addressable Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54

More information

Outdoor Temperature Sensor

Outdoor Temperature Sensor Didactum`s IP-based monitoring devices have many uses: Monitoring of wiring closets and server room environments Remote monitoring of technical rooms in branch offices Monitoring of power supply systems

More information

Fig.: A fire in a server room or data center may cause devastating damage. Protect your infrastructure.

Fig.: A fire in a server room or data center may cause devastating damage. Protect your infrastructure. Didactum`s IP-based monitoring devices have many uses: Monitoring of wiring closets and server room environments Remote monitoring of technical rooms in branch offices Monitoring of power supply systems

More information

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS NOVA PD56 Series Thermocouple, RTD, & Process Inputs Universal Power Supply 1-24 VAC Up to 3 Alarm Relays Retransmitting 4-2 ma Output Input Max/Min

More information

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1 Operation Manual Fighter ProVision Software Version: 0.0 Revision: 1 TABLE OF CONTENTS 1. Introduction 5 2. Software Installation 5 3. PC Users 6 3.1 Introduction 6 3.2 Default Code 6 3.3 Edit PC User

More information

SECTION LIGHTING CONTROLS

SECTION LIGHTING CONTROLS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 09 23 LIGHTING CONTROLS SPEC WRITER NOTE: 1. Delete between //----// if not applicable to project. Also, delete any other item or paragraph not applicable to

More information

SUPREMATouch. Modular Fire & Gas Detection System

SUPREMATouch. Modular Fire & Gas Detection System SUPREMATouch Modular Fire & Gas Detection System Fire & Gas Detection Solutions MSA permanent gas detection systems are used throughout the world to protect plant and personnel from hazardous gases in

More information

General Specifications

General Specifications General Specifications GS J0H-0E Model MVHK Digital Limit Alarm (DC Type) with Active Color PV Display General This plug-in type Digital Limit Alarm for DC input receives DC current or DC voltage signal.

More information

CAREL heatersteam Electric Element Steam Humidifiers

CAREL heatersteam Electric Element Steam Humidifiers Suggested Engineering Specifications Section 23 84 13 CAREL heatersteam Electric Element Steam Humidifiers 1. GENERAL SCOPE 1. Furnish and install as indicated on the drawings and plans, in-duct [space]

More information

Constant climate chambers

Constant climate chambers Constant climate chambers KBF P 240 (E2) - Constant climate chamber for photostability tests Specialized equipment for photostability tests. Integrated cooling of fans consistently compensates for the

More information

Process Alarm Solutions

Process Alarm Solutions Process Alarm Solutions Reliable Supervision and Control» Control. Monitor. Protect. SELCO Flexible alarm panels for supervision and control SELCO provides efficient and reliable solutions for alarm monitoring

More information

DES - DYNAMIC ESCAPE SYSTEM TUNNEL EMERGENCY LIGHTING VER.17.1

DES - DYNAMIC ESCAPE SYSTEM TUNNEL EMERGENCY LIGHTING VER.17.1 DES - DYNAMIC ESCAPE SYSTEM TUNNEL EMERGENCY LIGHTING VER.17.1 Awex brand has been existing in the emergency lighting sector since 2002, invariably fulfilling its clearly defined mission: top-quality state-of-the-art

More information

Combined CAN Sensor Unit Temperature, Humidity and Smoke

Combined CAN Sensor Unit Temperature, Humidity and Smoke Combined CAN Sensor Unit Temperature, Humidity and Smoke Didactum`s IP-based monitoring devices have many uses: Monitoring of wiring closets and server room environments Remote monitoring of technical

More information

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001 SLATE Base Module R8001A1001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform can

More information

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply   - Tel: Systems Index Systems - Systems Systems...1 -.16 General information Description...1 System description...2 Overview...3 Ordering details Arc monitor with detectors...4 Current sensing unit...5 Technical

More information

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation Gas Detection Control Panel MX Analog and digital controller or 8 lines / 6 to s max Highly versatile controller Cost savings on wiring installation The Fixed Gas Detection People www.oldhamgas.com an

More information

EC-BOS-602/616 AX Security

EC-BOS-602/616 AX Security D a t a s h e e t EC-BOS-602/616 AX Security Comprehensive, easy-to-use Access Control management solution Overview The heart of EC-Net AX Security is the EC- BOS-602/616 AX Security, an advanced IP-based

More information

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16 TraceTek TTSIM-1A TraceTek Sensor Interface Module with Relay Installation/OPERATION Instructions Approvals and Certifications TYPE NM General Signaling Equipment 76LJ Only AC versions are UL listed and

More information

C-Bus Four Channel General Input Unit Installation Instructions

C-Bus Four Channel General Input Unit Installation Instructions C-Bus Four Channel General Input Unit Installation Instructions 5504GI Series REGISTERED DESIGN REGISTERED PATENT Table of Contents Section...Page 1.0 Product Range... 3 2.0 Description... 3 3.0 Capabilities...

More information

DC Voltage Sensor. Specifications Didactum DC sensor: The sensor is automatically detected by the Didactum base unit. Accuracy: 1%

DC Voltage Sensor. Specifications Didactum DC sensor: The sensor is automatically detected by the Didactum base unit. Accuracy: 1% DC Voltage Sensor Didactum`s IP-based monitoring devices have many uses: Monitoring of wiring closets and server room environments Remote monitoring of technical rooms in branch offices Monitoring of power

More information

The Commercial LED Lighting Specialist

The Commercial LED Lighting Specialist 2 01 5 The Commercial LED Lighting Specialist LED DRIVERS PRODUCT CATEGORY DATA SHEET Our Service, Our People, Your Choice LED Drivers LED Driverss The Commercial LED Lighting Specialist In response to

More information

Panel Mounted Fault Annunciator Series

Panel Mounted Fault Annunciator Series Panel Mounted Fault Annunciator Series BSM / USM Panel-mounted fault annunciator Annunciators for panel mounting with 8, 16, 24, 32, 40 and 48 signal inputs Status retention of inputs and sequence in case

More information

REMOTE MONITORING AND ALARM SYSTEM

REMOTE MONITORING AND ALARM SYSTEM FUNCTIONALITY A. The water and wastewater facilities remote monitoring, reporting and alarm notification system shall be comprised of a hosted, Web-based user-interface which communicates to remotely monitored

More information

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P Contents Description Data Sheet No. Page Overview P-1.50.001E 117-118 Technical Data SFI-plus P-1.50.002E-1, 2 119-120 Dimensions

More information

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax: Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 505 Grünberg Tel.: 060 807-0 Fax: 060 807-59 A-ISOMETER IRDH575 Insulation monitoring device for unearthed AC, DC and AC/DC systems (IT systems) with

More information

Danfoss gas detection unit Type GD Heavy Duty

Danfoss gas detection unit Type GD Heavy Duty Data sheet Danfoss gas detection unit Type GD Heavy Duty The Heavy Duty gas detection units are used for monitoring and warning of hazardous Ammonia gas concentrations. They are intended for ATEX/ IECEx

More information

RACK MONITORING SYSTEM - RAMOS Ultra

RACK MONITORING SYSTEM - RAMOS Ultra CONTEG DATA SHEET version: 9-05-0 COMPLEMENTARY SYSTEMS RACK MONITORING SYSTEM marketing@dafnia.com www.dafnia.com ABU DHABI UAE +97 55575 DUBAI JAFZA +97 4 5995 +97 4 8840 MUSCAT DOHA OMAN +968 4 75005

More information

ECO PDU PE7214/PE7216/PE7324/PE7328

ECO PDU PE7214/PE7216/PE7324/PE7328 ECO PDU PE7214/PE7216/PE7324/PE7328 As part of its NRGence line, ATEN has developed a new generation of green energy power distribution units (eco PDUs) to effectively increase the efficiency of data center

More information

HRX Technical Manual. Version 1.2

HRX Technical Manual. Version 1.2 HRX 5000 Technical Manual Version 1.2 Contents: Specification...2 Connectors...5 RS-485 Network Connectors (J6 and J7)...5 RS-232 to Printer (J19)...6 RS-232 to PC (J8)...7 TCP/IP...8 Power (J21)...9 Fire

More information

IntesisBox BACnet/IP Server - Notifier ID3000 series

IntesisBox BACnet/IP Server - Notifier ID3000 series IntesisBox Server - Notifier ID3000 series Gateway for integration of Notifier ID3000, ID3002, ID50 and ID60 fire panels into enabled control systems. Integrate your Notifier fire panels into your BACnet

More information

Two-Channel Gas Controller

Two-Channel Gas Controller Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously

More information

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options.

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options. All icon products are Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options. Certified to global standards: ATEX, IECEx, TIIS, EAC-EX, ETL approved

More information

3M Oldham MX 43 Controller

3M Oldham MX 43 Controller Description Fully scalable, and designed to functional safety performance level standards, the MX is an analog and digital controller that continuously measures and controls gases in the atmosphere. The

More information