W7121A Telephone Lighting Module

Size: px
Start display at page:

Download "W7121A Telephone Lighting Module"

Transcription

1 W7A Telephone Lighting Module FEATURES PRODUCT DATA Simple add-on to Honeywell 7000 Alarm Systems. Convenient access from any touch-tone telephone at home or away. Quality voice-prompted operation. Works with remote answering services. Unique approach to lighting; no schedules to program. Built-in celestial clock that operates lights after dark. Simple H-Bus system connection. Controls up to 6 separate lights using existing home power wiring. APPLICATION The W7A Telephone Lighting Module (TLM) is an accessory device that adds remote telephone access, lighting control and future thermostat control capabilities to the Honeywell 7000 Alarm System (model W70C only). The W7A offers users the convenience of using the telephone to check and change the status of their security. It also offers enhanced safety features that automatically turn on lights during alarms, when the occupants depart and return, and randomly when the occupants are away. Contents Application... Features... Specifications... Ordering Information... Installation... User System Operation... 9 User Operating Scenarios... 9 Checkout and Troubleshooting... 0 U.S. Registered Trademark Copyright 999 Honeywell Inc. All Rights Reserved 68-0-

2 SPECIFICATIONS Electrical Ratings: System Power: Nominal.8 Vdc with battery standby when connected to 7000 Control Panel. Power Consumption: 60 ma at.8v. Telephone Operation: Ringer Equivalence: 0.0B. Connection: Modular cable to jack. Wiring: Interface: Four-Wire H-Bus (cable no. AK 4500AWH, AWG). Maximum Wire Length: AWG: 50 feet.. 8 AWG: 500 feet. End of Line (EOL) Resistor: 0 ohm 5% /4 watt resistor at last bus device. Lighting: Cable: Modular to X0 Power Line Carrier (PLC) modules PL5 or PSC04. Thermostat: Port for future use. Environment Ratings: Ambient Temperature : F (0 C) to 0 F (49 C). Humidity: Less than 85% relative humidity, continuous, non-condensing. Dimensions: 6-/ in. (65 mm) wide x 4-/4 in. (08 mm) high x -/6 in. (0 mm) deep. Required Equipment: System with W70C Control Panel. Model PL5 or PSC04 Signaling Module from X0 and X0 PRO. Optional Equipment: W7A Telephone Lighting Module, Point Expansion Module, or RF Expansion Module. (Up to two modules can be installed in a Metal Enclosure with a Subpanel.) 0007 Modular Block Assembly (Connects both the System 7000 Control Panel and the W7A Telephone Lighting Module to a single block. INSTALLATION When Installing This Product.... Read these instructions carefully. Failure to follow them can damage the product or cause a hazardous condition.. Check the ratings given in the instructions and marked on the products to make sure the product is suitable for the application.. Installer must be a trained service technician. 4. After installation is complete, check out the product operation as provided in these instructions. Fig. is a general overview of the entire 7000 System. See form 69-9 for detailed information for all other system elements. Refer to Honeywell 7000 System Product Data, form 69-9, for additional details. Approvals: FCC, Part 68, Compliant. FCC Registration Number: B7FMEX-578-AL-N. ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE wholesaler or distributor, refer to the TRADELINE Catalog or price sheets for complete ordering number. If you have additional questions, need further information, or would like to comment on our products or services, please write or phone:. Your local Home and Building Control Sales Office (check white pages of your phone directory).. Home and Building Control Customer Logistics Honeywell Inc., 985 Douglas Drive North Minneapolis, Minnesota In Canada Honeywell Limited/Honeywell Limitée, 5 Dynamic Drive, Scarborough, Ontario MV 4Z9. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A. 68-0

3 MODES OPTIONS OK CANCEL TELCO LINES PRIMARY PLUG-IN TRANSFORMER J TB S HORN/BELL SECONDARY BATTERY SMOKE DETECTOR W70C CONTROL PANEL HARDWIRE LOOPS W7A TELEPHONE LIGHTING MODULE FIRE POLICE SPECIAL PLUG INTO 0 VAC RF TRANSMITTERS HBUS KEYPAD 0 PL5 OR PSC04 PLC INTERFACE POINT EXPANSION MODULE (PEM) HARDWIRE LOOPS RF EXPANSION MODULE (RFEM) RF RECEIVER M8006A Fig.. Honeywell 7000 System Overview with W7A Telephone Lighting Module. W7A Telephone Lighting Module The W7A Telephone Lighting Module requires connecting a separate telephone line jack between the System 7000 control panel and a telephone in the home. The W7A must also be connected to the system through an H-Bus and attached to a PL5 or PSC04 PLC Interface Module with a modular cable. Then, on the correct ring count from a remote telephone call or when an on-premises telephone is picked up and the asterisk (*) key is pressed three times, the W7A engages and makes a W7A connection. The W7A then obtains status information and sends arming commands to the control panel via the H-Bus. The W7A also listens to the H-Bus and, in response to events and time, the W7A logic sends X0 lighting on and off messages to the PL5 or PSC04 Module. W7A Installation CAUTION Equipment Damage Hazard. Static electricity can damage circuit boards. Follow electrostatic discharge (ESD) safety procedures when handling or installing circuit boards.. Locate the W7A within eight feet (.44 meters) of an available ac outlet and with easy access to the connector.. Mount remotely within 50 feet (76 meters) of the control panel when using AWG wire or 500 feet (5 meters) when using 8 AWG wire.. Remove the W7A circuit board from the plastic box. 4. Use the box to mark the mounting screw locations on the wall or plywood. 5. Mount the W7A with two screws (not supplied). 6. Insert the W7A circuit board as shown in Fig

4 MOUNTING SLOTS ON BACK OF TLM ANCHORS DRYWALL OR PLYWOOD NOT SUPPLIED TLM (COVER REMOVED) M8007A Fig.. Installing W7A TLM. W7A Wiring Use this basic wiring procedure, see Fig. through 6:. Use AK4500A four conductor twisted cable to connect the W7A to other H-Bus devices. Observe all the H-Bus rules including terminating the H-Bus signaling wire pair with a 0 ohm resistor whenever the W7A is the last device on the line.. Install or request the installation of a second and separate jack.. Use modular telephone cable between the and the W7A telephone jack. 4. Use the cable provided to connect the W7A lighting jack to the signaling module. 5. Plug the X0 signaling module into a non-switched 0 Vac power outlet

5 SYSTEM 7000 CONTROL BOARD W7A TB HBUS HUBS + COM +.8 VDC 4 ON S J +.8 VDC COM HBUS + HBUS 4 4 J 8 X0 POWER LINE INTERFACE 7 TIP (GREEN) FROM (7000 PANEL) RING (RED) RING (RED) TIP (GREEN) TO LOCAL PHONES M800 Fig.. W7A TLM wiring, single receptacle. SYSTEM 7000 CONTROL BOARD W70C (7000 CONTROL PANEL) W7A TB HBUS HUBS + COM +.8 VDC 4 ON S J +.8 VDC COM HBUS + HBUS 4 4 J TIP (GREEN) RING (RED) TIP (GREEN) TO LOCAL PHONES X0 POWER LINE INTERFACE FROM TELCO TIP (GREEN) RING (RED) RING (RED) M8004 Fig. 4 W7A TLM wiring, dual receptacles

6 TO SYSTEM 7000 CONTROL TO W70C FROM TO W7A FROM TO W7 TLM M8008A Fig Modular Block Assembly. W70C SYSTEM 7000 CONTROL BOARD W7A TB HBUS HUBS + COM +.8 VDC MODULAR BLOCK ASSEMBLY ON S 4 J J +.8 VDC COM HBUS + HBUS 4 MODULAR CABLE TO TELCO X0 POWER LINE INTERFACE M8005 Fig. 6. W7A TLM wiring using Modular Block Assembly

7 W7A House Code Configuration Select a house code from letters A through P to be used later to bind the addresses of all the lighting modules to the W7A. Table shows the position of the DIP switches on the W7A Module. Table. W7A House Codes. House Code DIP Position DIP Position DIP Position DIP Position 4 A 0 a B C D 0 0 E F 0 0 G 0 0 H 0 I J 0 0 K 0 0 L 0 M 0 0 N 0 O 0 P a Indicates position of S: 0 = off, = on. Installation Sequence. Install and program the System 7000 (W70C only). a. Use System 7000 firmware and programming software, Revision.0 or higher. b. Enable passcode 5, defining the telephone access code for the system. c. Enter the applicable zip code to enable the system to calculate the sunset time.. Install the Modular Block Assembly or request the installation of a second jack on the house side of the for the 7000 System.. Install and connect the W7A using the instructions that follow. 4. Install the lighting modules. Select a house code by setting the W7A DIP switch. 5. Set the same house code and individual unit codes on each module for the desired application in Table. 6. Connect the thermostat if applicable (future option). 7. Use the house telephone to change the W7A configuration settings such as ring count. 8. Check out and test the system. Lighting PL5 or PSC04 PLC Interface Module The PL5 (X0) or PSC04 (X0 PRO) modules convert the W7A commands into X0 Power Line Carrier (PLC) messages that are imposed onto the power line and run throughout the home over the existing wiring. These signals are then received by X0, X0 PRO or Leviton smart switches, receptacles or modules. Lighting Design Identify the lights the customer has chosen for the system to operate automatically:. Entry and exit.. Lived-in look.. Alarm. Up to 6 unique addresses are allowed, although many lights that are always turned on and off at the same time can share the same address. Eight addresses are dedicated to entry and exit, five more to lived-in-look, and an additional three to alarm only lighting. Note that the options available in Table have some lights come on at any time, 4 hours a day, for a dark hallway, for example, and have others only come on at night, such as a porch light. Some of the entry and exit lights and some lived-in-look lighting come on only after sunset and before sunrise. If the system is armed with an Away State (Mode ), lived-in-look lights operate randomly after sunset until approximately 0:0 PM. All lights come on in the event of an alarm regardless of the time of day and stay on for an hour. After identifying the lights to be operated by the system, have an electrician replace the switches and receptacles that control these lights with smart addressable switches and receptacles that use the X0 protocol (a variety of styles and colors are available from Leviton, X0 or X0 PRO). Honeywell part number 0905 Plug-in Lighting Module, and part number Appliance Module, are also available and can be used as options. Consider providing ways for the user to manually operate addressable lights by providing desktop or wall mounted lighting controllers (especially for plug-in lights). To suppress sources of interference from power line noise, have the electrician provide filtering and bridging when signaling is required between different power phases. NOTE: Built-in transient protection in some power strips and instant-on circuits in some TV s can also affect power line signaling. Configuring Lighting Modules. Select a House code. Each lighting module has a switch with a letter from A through P. Select a code to be used by this house. Avoid letter A because it is a common out of box setting and P because it is also used as a code by X-0 test equipment.. Select a Unit code. Each module has a second switch with numbers from to 6. Choose and set the number for the desired application shown in Table.. Whenever you have only a few lights on, always select one light to come on and remain on. 4. Choose device codes in the middle of the range (module unit numbers 8 to 0) that are set to operate more frequently

8 Table. Selecting A Unit Code. Applicable Lighting Module Unit Numbers Application How It Works Pathway Lighting Inside (4 hour) Pathway Lighting Outside (After Dusk) Always On During Lived-In Look Active Lived-In Look Option Subdued Lived-In-Look Option Limited Lived-In-Look Option (use for homes with fewer lights) Alarm Always on for three minutes on exit; stays on for entry. Lights on entry and exit only between sunset and sunrise. Comes on and stays on while Armed-Away between sunset and sunrise. Random operation every 0 to 5 minutes while Armed-Away between sunset and sunrise ( to 6 lights on at start). Random operation every 0 to 0 minutes while Armed-Away between sunset and sunrise ( to lights on at start). Random operation every 0 to 5 minutes while Armed-Away between sunset and sunrise ( to lights at start). Light on alarm, shut off an hour after bell timeout. Programming Requirements System 7000 For the W7A to work properly, program this information into the System 7000:. Zip Code: So the system can compute the correct sunrise and sunset time.. Mode : Selected when the user responds to the telephone prompts to arm the system. Configure for the arming security requirements the user specifies.. Passcode 5: Passcode the W7A uses for remote telephone access. Program a number and enable the passcode. 4. Date and Time: The W7A gets its time from the System 7000 whenever a new time is set via the keypad; it requests a daily time update. W7A TLM Program this information:. House Code: Choose the house code by setting the DIP switch on the W7A and the rotary switches on the lighting modules.. Number of Rings: Set the ring count to a value greater than any answering machine sharing the telephone line and less than the System 7000 ring count. Hidden Configuration Menus W7A TLM configuration is hidden from the homeowner. To access these configuration menus:. Pick up the telephone and enter three asterisks (***).. Enter three asterisks (***) when the system prompts you to arm or disarm. A prompt, Press to change lighting, appears. Pressing digit,, or on the telephone allows you to select between Lived-In-Look options. See Table. NOTE: Pressing Digit Only options 0 and are prompted by the voice message. 0 Disables. Table. Lived-In-Look. Does the Following to the Lived-In Look Operation Enables Active Look. Enables Subdued Look. Enables Limited Look. # Returns to configuration menu. Thermostat Option (Future Option) Not available at this time

9 Dusk Offset (Table 4) The system turns on certain lights after computing sunset for the area. Pressing allows you to change the Lived-In-Look lighting start time in one-half hour increments. Use this setting for circumstances that cause darkness earlier or later than the official sunset time, such as living on the side of a mountain. You can make the changes in Table 4 after pressing. Pressing Digit Table 4. Dusk Offset. Number of Rings (Tables 5 and 6) Pressing 4 allows you to configure the number of rings required before the W7A picks up on a remote telephone call. Setting the count to zero disables the Remote Telephone Access function. The ring count for the W7A should be set higher than any device that shares the same telephone line, such as an answering machine, and less than the System 7000 programming ring count. Set the ring count according to Table 5. Table 5. Number of Rings. Note that System 7000 can listen for a programmer tone after the answering machine is on line. Whenever an answering machine is present or a customer subscribes to a remote answering service from the telephone company, the user needs to place two quick consecutive calls to connect to the W7A. It picks up after two rings followed by a ten second pause followed by two more telephone rings. See Table 6. Pressing Digit Does the Following to the Dusk (sunset) starting time. 0 Decrease by / hour. Increase by / hour. # Return to the configuration menu. Device Answering Machine W7 or more. Number of Rings More than answering machine Control More than W7. Table 6. Changing Ring Count. Does the Following 0 to 9 Changes the ring count to the selected digit (0 through 0 where 0 disables the system). # Returns to the configuration menu. Light Test Use this menu to test the lighting operation. From the configuration menu, pressing digit 9 causes all 6 lights to come on and turn back off in the same order. USER SYSTEM OPERATION Telephone Access The W7A allows the user to operate their system from any touch tone telephone. Any person that knows passcode #5 can pick up a telephone and do the following: When At Home: Enter three asterisks ( ***). The system informs the user of the system status and provides voice prompts for arming or disarming the system (or changing the temperature when the thermostat is attached). Arming/Disarming System While at Home: The homeowner can arm and disarm the system from a touch tone telephone at home. Enter three asterisks (***) to get into the system. Follow instructions to arm the system by pressing or disarm the system by pressing 0 (zero). NOTE: Arming the system from a home telephone selects Mode 4, which is typically programmed as the SLEEP mode. When Away: The user can dial the home telephone number and let it ring the correct number of rings. If the line is shared with other equipment or telephone company services, the user must let it ring twice, hang up for ten seconds, then dial the number again to let the telephone ring two more times. This procedure must be completed within 40 seconds. When the W7A picks up, the user is prompted to enter a remote access passcode (#5). After being informed of the system status, the user is voice prompted for arming or disarming the system (or changing the temperature when the thermostat is attached). Turning Off All Lights: The user can turn off all lights from the home telephone by picking up the phone and entering three asterisks (***) followed immediately by the number 9. The user will hear a beep and all lights will go off. This feature is especially convenient following an alarm or when going to sleep. Hacker: After four consecutive incorrect passcode tries, the W7A hangs up, displays a Hacker message on the keypad and turns itself off for fifteen minutes. USER OPERATING SCENARIOS The addition of the Telephone Lighting Module to a System 7000 adds convenient automatic operation of lights and can save energy and increase comfort. Common user scenarios are: Leaving The Home: User arms the system to leave (using any mode that has an AWAY state selected). The selected Entry/Exit lights come on to light the user s way through the hallways and then turn off after three minutes. (If later a communicating thermostat is attached, it is changed to an energy saving away state.)

10 While Away: The user can use any touch tone telephone to call home and use passcode number 5 to get into the system and do the following:. Check Status: System may be Ready, Not Ready, In Alarm, Not Responding, or In Mode X (where X is the mode number through 6).. Arm System: The user can press the number to arm the system to Mode only if the system is ready.. Disarm System: An armed or alarmed system can be disarmed by a user with passcode number Adjust Temperature (Future Option): When a thermostat is attached in the future, the user can get the temperature of the home and increase the temperature in one degree increments. 5. While Away After Dark: When the system is armed, the W7A starts randomly turning selected lights on and off until ten to eleven PM. If the system remains armed after that time, the W7A turns off all Lived-In-Look lights. Random Lived-In-Look lighting stops whenever someone disarms the system. Returning Home: When the user enters the home through an entry/exit door, the entry warning sounds and pathway lights come on and stay on until the user turns them off manually. Alarm While At Home or Away: In the event protection is violated on an armed system, all selected lights will come on and stay on for an hour. CHECKOUT AND TROUBLESHOOTING Checkout NOTE: The W7A takes approximately one minute to adjust to a new time setting.. Test that all lights come on and off using hidden menu 9 and the local telephone.. Check that the correct lights come on entry and exit.. Check that all lights come on in the event of an alarm. 4. Change the system time to some time after dark and check entry and exit and random operation of Lived-In- Look. (Some lights change every ten to fifteen minutes. Lights are never all on or all off.) 5. Check the ability to arm and disarm the system from the local telephone. 6. Use a second line or cellular telephone to check that the W7A responds to the correct ring count. 7. Check that there are no problems with other equipment sharing the same telephone line. Troubleshooting Table 7 lists trouble messages, problems and possible solutions. Table 7. Troubleshooting. What You See What Could Be Wrong What You Should Do W7A does not power up (W7A LED does not come on). Error in H-Bus connection.. Check for.8 Vdc between terminals and 4.. Check for plus polarity on terminal. LED does not flash. Error in H-Bus data connection. Check polarity of H-Bus data line. Does not respond to local control. No beep heard after entering three asterisks (***) on local telephone. W7A does not pick up telephone on remote telephone call. System Not Responding message heard when making remote call. Error in wiring. Interference by other device(s) sharing telephone line. Incorrect ring count. Wiring problem. Number of rings set to zero. Error in H-Bus (data) wiring.. Verify telephone wiring.. Temporarily plug into primary connection and try again. Set W7A ring count to a number higher than other devices sharing the line. Use two calls with ten-second pause to access the W7. Check telephone wiring. Set W7A ring count to a number higher than other devices sharing the line. Check that the W7A LED is pulsing (once per second). None of the lights work. Wrong house code. Check and correct code. Bad connection to PLC Interface. Check modular plugs and wiring. Plugged into receptacle that is switched off. Plugged into power strip that is not X0 compatible. Move to unswitched receptacle. Plug directly into outlet, bypassing power strip or replace power strip. continued

11 Table 7. Troubleshooting (Continued). What You See What Could Be Wrong What You Should Do A certain light never works. Signal is not getting to other phase of wiring system. Power line noise interference. Power ine loading. Turn on 0 Vac appliance such as dryer to provide temporary path between phases and verify problem. Locate source of noise by unplugging other electrical equipment. Reconnect noisy source using plug-in filter. Unplug equipment to locate cause. Plug loading device into different outlet. Lights work some of the time. Power line noise/interference. Locate source of noise by unplugging other electrical equipment. Use plug-in filter to reconnect noisy source. Poor connection on the neutral side of the power line (also a hazard to the homeowner). Have electrician tighten power connections. Lights operate by themselves. Neighbor or other system using the same household code. Change house code on W7A and all modules. Telephone Problems In the event of telephone problems, disconnect the control panel by removing the plug from the (CA8A in Canada) wall jack. This should leave the rest of the house phones in service if the problem is with the security equipment. Do not disconnect the phone connection inside the W7A or the local phones will be out of service. If the telephone service is still out after disconnecting the security system, the problem is with the phone system and they should be contacted for service. If the phone service returns when the security system is disconnected, Honeywell should be contacted for service. Federal Communications Commission (FCC) Statement This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following statement for your information: This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer s instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for Class B computing device in accordance with the specifications in Part 5 of FCC Rules, which are designed to provide reasonable protection against such interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:. If using an indoor antenna, have a quality outdoor antenna installed.. Reorient the receiving antenna until interference is reduced or eliminated.. Move the receiver away from the control/ communicator. 4. Move the antenna leads away from any wire runs to the control/communicator. 5. Plug the control/communicator into a different power outlet so that it and the receiver are on different branch circuits. 6. If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. 7. If necessary, consult the booklet entitled Interference Handbook, prepared by the FCC. It is available from the U.S. Government Printing Office, Washington, DC 040. The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User s Manual. Unauthorized changes or modifications could void the user s authority to operate the equipment. This equipment complies with Part 68 of the FCC rules. On the front cover of this equipment is a label that contains, among other information, the FCC registration number and ringer equivalence number (REN) for this equipment. If requested, this information must be provided to the telephone company. The REN is needed to determine the quantity of devices that may be connected to the telephone line. Excessive REN on the telephone line may result in the devices not ringing in response to an incoming call. In most, but not all areas, the sum of the REN should not exceed five (5). To be certain of the number of REN that may be connected to your telephone line, add up the REN on your line and call the local telephone company and verify that you are below the maximum limit for your area. If this equipment causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. If advance notice is not practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe necessary. 68-0

12 The telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the operation of the equipment. If this happens, the telephone company will provide advance notice in order for you to make the necessary modifications in order to maintain uninterrupted service. If trouble is experienced with this equipment, please contact the manufacturer for repair and warrantee information. If the trouble is causing harm to the telephone network, the telephone company may request you to remove the equipment from the network until the problem is resolved. This equipment uses a to connect the W7A to the telephone network. There are no user serviceable components in this product, and all necessary repairs must be made by the manufacturer. Other repair methods may invalidate the FCC registration on this product. This equipment cannot be used on telephone companyprovided coin service. Connection to Party Line Service is subject to state tariffs. This equipment is hearing-aid compatible. When programming or making test calls to an emergency number, prior to initiating alarms, briefly explain to the Monitoring dispatcher the reason for the call. Perform such test activities in the off-peak hours such as early morning or late evening. Home and Building Control Honeywell Inc. Honeywell Plaza P.O. Box 54 Minneapolis MN Honeywell Latin American Region 480 Sawgrass Corporate Parkway Suite 00 Sunrise FL 5 Home and Building Control Honeywell Limited-Honeywell Limitée 55 Gordon Baker Road North York, Ontario MH N7 Honeywell Europe S.A. Avenue du Bourget 40 Brussels Belgium Honeywell Asia Pacific Inc. Room -5 Sun Hung Kai Centre No. 0 Harbour Road Wanchai Hong Kong Printed in U.S.A. on recycled paper containing at least 0% 68-0 G.R. Rev post-consumer paper fibers.

C6097A,B Pressure Switches

C6097A,B Pressure Switches C6097A,B Pressure Switches FEATURES PRODUCT DATA APPLICATION The C6097 Pressure Switches are safety devices used in positive-pressure or differential-pressure systems to sense gas or air pressure changes.

More information

EL7611A/EL7612A Ultrasonic Occupancy Sensors and EL7621A Power Pack PRODUCT DATA

EL7611A/EL7612A Ultrasonic Occupancy Sensors and EL7621A Power Pack PRODUCT DATA EL7611A/EL7612A Ultrasonic Occupancy Sensors and PRODUCT DATA Proven 30% to 60% utility cost savings because lights are on only when needed. Low initial cost allows fast payback. Models available for 1000

More information

T8011R Programmable Heat Pump Thermostat

T8011R Programmable Heat Pump Thermostat T8011R Programmable Heat Pump Thermostat FEATURES PRODUCT DATA APPLICATION The T8011R Heat Pump Thermostat provides 24 Vac control of a two-stage heating and one-stage cooling heat pump system with manual

More information

F25F Media Air Cleaner

F25F Media Air Cleaner F25F Media Air Cleaner FEATURES PRODUCT DATA High efficiency media filter captures particles as small as 1.0 micron. Efficiency and arrestance ratings based on the American Society of Heating, Refrigerating

More information

OUT TO WALLJACK. Input

OUT TO WALLJACK. Input Innovative Technologies in Custom Electronic Design & Manufacturing Thank you for purchasing our Intermediate FreezeAlarm, model FA-I. The FreezeAlarm Intermediate model will automatically call up to three

More information

RA889A Switching Relay

RA889A Switching Relay Switching Relay FEATURES PRODUT DATA High load switching capability. Troubleshooting LED. Push-to-test button. Replaceable transformer fuse. Long-life D relay drive control technology. Relay for use with

More information

TG509, TG510, TG511, TG512 Versaguard Universal Thermostat Guards

TG509, TG510, TG511, TG512 Versaguard Universal Thermostat Guards TG509, TG510, TG511, TG512 Versaguard Universal Thermostat Guards FEATURES PRODUCT DATA TG509 TG511D TG510A TG512B Available in four sizes: mini, small, medium and large, to fit virtually all thermostats.

More information

H1008A,D Automatic Humidity Controls

H1008A,D Automatic Humidity Controls H00A,D Automatic Humidity Controls FEATURES PRODUCT DATA The H00A,D provides automatic control for by-pass flow-through, powered flow-through, steam and drum humidifiers in central heating systems. The

More information

Rev C May GE Interlogix. Part No: R. CareGard. User Guide

Rev C May GE Interlogix.   Part No: R. CareGard. User Guide g 466-1936 Rev C May 2003 GE Interlogix www.ge-interlogix.com Part No: 60-883-95R CareGard User Guide FCC Notices FCC Part 15 Information to the User Changes or modifications not expressly approved by

More information

T8524 Deluxe Electronic Thermostat

T8524 Deluxe Electronic Thermostat T8524 Deluxe Electronic Thermostat PRODUCT DATA T8524 FEATURES AND BENEFITS APPLICATION The T8524 Deluxe Electronic Thermostat provides electronic control of 18 to 30 Vac multistage heating and cooling

More information

T4098A,B Deluxe Electric Heat Thermostats

T4098A,B Deluxe Electric Heat Thermostats T4098A,B Deluxe Electric Heat Thermostats FEATURES PRODUCT DATA Controls both fan-forced and baseboard electric heaters. Temperature-responsive, vapor-filled dual diaphragm sensing element provides 2 F

More information

FreezeAlarm. General Description FA-D /FA-D-AAB. Applications. Features. Specifications. Dimensions

FreezeAlarm. General Description FA-D /FA-D-AAB. Applications. Features. Specifications. Dimensions Innovative Technologies in Custom Electronic Design & Manufacturing General Description The FA-D (fahrenheit) and FA-D-AAB (celsius) FreezeAlarm monitors temperature, power status, security or an external

More information

CR7075 Two-Stage Lighting Controller

CR7075 Two-Stage Lighting Controller CR707 Two-Stage Lighting Controller FEATURES PRODUCT DATA Light intensity threshold levels field-adjustable by user. Independent Time of Day (TOD) override inputs. Optimum start/stop of lighting loads.

More information

T6984F,G Electronic Floating Control Thermostats

T6984F,G Electronic Floating Control Thermostats T6984F,G Electronic Floating Control Thermostats FEATURES PRODUCT DATA P+I control action provides accurate, stable room temperature control. Used with ML644 Series 60 Direct Coupled Damper Actuators.

More information

8VHU*XLGH K4254V3 6/01

8VHU*XLGH K4254V3 6/01 8QLYHUVDO9RLFH 6\VWHP 896 896²(8$ 8VHU*XLGH K4254V3 6/01 Table of Contents ABOUT THE UNIVERSAL VOICE SYSTEM (UVS)...3 USER OPERATION SUMMARY...4 2-WAY VOICE OPERATION (CENTRAL STATION)...6 2-WAY VOICE

More information

C554A Cadmium Sulfide Flame Detector

C554A Cadmium Sulfide Flame Detector C554A Cadmium Sulfide Flame Detector FEATURES PRODUCT DATA Cadmium sulfide sensing element provides faster response than bimetal sensors. On flame failure, the cad cell causes the oil primary control to

More information

T4398A,B High Performance Electric Heat Thermostats

T4398A,B High Performance Electric Heat Thermostats T498A,B High Performance Electric Heat Thermostats FEATURES PRODUCT DATA Controls both fan-forced and baseboard electric heaters. Temperature-responsive, vapor-filled dual diaphragm sensing element provides

More information

Interactive Technologies Inc North 2nd Street North St. Paul, MN Technical Manuals Online! -

Interactive Technologies Inc North 2nd Street North St. Paul, MN Technical Manuals Online! - Security System Owner s Manual Interactive Technologies Inc. 2266 North 2nd Street North St. Paul, MN 55109 FCC Notices FCC Part 15 Information to the User Changes or modifications not expressly approved

More information

Technical Manuals Online! A B C DEF GHI JKL POWER 9 0 COMMAND YZ. User's Guide

Technical Manuals Online! A B C DEF GHI JKL POWER 9 0 COMMAND YZ. User's Guide 1 2 3 4 A B C DEF GHI JKL 5 6 7 8 MNO PQR STU VWX 9 0 COMMAND YZ User's Guide POWER Technical Manuals Online! - http://www.tech-man.com This equipment complies with part 68 of the FCC rules. On the top

More information

Independent Zone Control (I.Z.C.)

Independent Zone Control (I.Z.C.) Operation and Installation Guide Independent Zone Control (I.Z.C.) DELAYED INSTANT ARMED 1 2 3 4 7 5 6 8 9 * * fi Radionics R D279A Operation & Installation Guide 46456B Page 2 Copyright 2000 Radionics

More information

Model 17A00 Expansion Enclosure

Model 17A00 Expansion Enclosure HOME AUTOMATION, INC. Model 17A00 Expansion Enclosure Installation Manual Document Number 17I00-1 Rev A March, 2002 Home Automation, Inc. Model 17A00 Expansion Enclosure Installation Manual Document Number

More information

Supervised Security System Owner's Guide

Supervised Security System Owner's Guide Owner's Guide PSC06 READ THIS FIRST This equipment generates and uses radio frequency energy, and if not installed and used properly, that is, in strict accordance with the manufacturers instructions,

More information

Quick start guide. SB3014-WM DECT 6.0 expansion wireless mic for use with AT&T model SB3014

Quick start guide. SB3014-WM DECT 6.0 expansion wireless mic for use with AT&T model SB3014 Quick start guide SB3014-WM DECT 6.0 expansion wireless mic for use with AT&T model SB3014 Congratulations on purchasing this AT&T product. For customer support or product information, visit our website

More information

GE Security Fire & Life Safety F-DACT(F) Digital Alarm Communicator Transmitter Installation Sheet

GE Security Fire & Life Safety F-DACT(F) Digital Alarm Communicator Transmitter Installation Sheet GE Security Fire & Life Safety F-DACT(F) Digital Alarm Communicator Transmitter Installation Sheet Description The F-DACT(F) is a digital alarm communicator transmitter for F-series fire alarm control

More information

User's Manual 5120XM N8031 6/96

User's Manual 5120XM N8031 6/96 Fire and Burglary System User's Manual 5120XM N8031 6/96 SYSTEM OVERVIEW...3 General...3 Zones...3 Fire & Emergency Protection...3 Burglary Protection...4 Alarms...4 Memory of Alarm...4 ABOUT THE KEYPADS...5

More information

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor A1UL PERS Personal Emergency Response System TABLE OF CONTENTS 1. READ THIS FIRST... 1 2. SYSTEM OVERVIEW.. 1 3. COMPONENTS 2 4. UNIT OPERATION! Standby Mode.. 3! Emergency Activation. 3! Answering Incoming

More information

T7984 A,B,C Electronic Modulating Control Thermostats

T7984 A,B,C Electronic Modulating Control Thermostats T7984 A,B,C Electronic Modulating Control Thermostats FEATURES PRODUCT DATA APPLICATION These microprocessor-based thermostats provide proportional - integral (PI) individual room temperature control in

More information

AMERIPHONE products are manufactured by Walker, A Division of Plantronics, Inc Western Avenue, Garden Grove, CA (800) VOICE

AMERIPHONE products are manufactured by Walker, A Division of Plantronics, Inc Western Avenue, Garden Grove, CA (800) VOICE AMERIPHONE products are manufactured by Walker, A Division of Plantronics, Inc. 12082 Western Avenue, Garden Grove, CA 92841 (800) 874-3005 VOICE (800) 772-2889 TTY/TDD (714) 897-4703 FAX email: ameriphonecs@plantronics.com

More information

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20 Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20 PRODUCT DATA FEATURES Solid or split core loop-powered current transmitters Fast response time Integral DIN rail mounting flange

More information

User s Manual. System Information... 3 Using the Touchpad Buttons... 3 General Operation... 4 Using Systems with Keyswitches... 4

User s Manual. System Information... 3 Using the Touchpad Buttons... 3 General Operation... 4 Using Systems with Keyswitches... 4 ITI Part No. 60-562-03 60-562-06 $GYHQWŒ&RPPHUFLDO )LUH6\VWHP Document Number: 466-1705 Rev. B November 2001 System Information... 3 Using the Touchpad Buttons... 3 General Operation... 4 Using Systems

More information

The T6140A,B Remote Bulb Temperature Controller

The T6140A,B Remote Bulb Temperature Controller T640A,B Remote Bulb Temperature Controller The T640A,B Remote Bulb Temperature Controller is used as a unit mount temperature controller in electric heat, fan coil, room air conditioner applications, cold

More information

Solid Core and Split Core 0-5, 0-10 Vdc Output Current Sensors CTS-05,10; CTP-05,-10

Solid Core and Split Core 0-5, 0-10 Vdc Output Current Sensors CTS-05,10; CTP-05,-10 Solid Core and Split Core 0-5, 0-10 Vdc Output Current Sensors CTS-05,10; CTP-05,-10 DESCRIPTION FEATURES PRODUCT DATA Solid and Split Core Vdc Output Current Transmitters. Fast Response Time. Integral

More information

INSTALLATION MANUAL PC25OO

INSTALLATION MANUAL PC25OO INSTALLATION MANUAL PC25OO NOTES ON UL INSTALLATION This equipment is UL listed in accordance with UL standard 1023 (Household Burglar Alarm System Units), UL standard 985 (Household Fire Warning Units)

More information

Panic. Part Number SYSTEMS, Inc.

Panic. Part Number SYSTEMS, Inc. 1 2 3 4 5 6 0 7 8 Panic 9 # Part Number 5-051-264-01 Rev C SYSTEMS, Inc Thank you for purchasing this C&K alarm system Your system is one of the most powerful and advanced alarm systems on the market today,

More information

FTP-1000 Touchpad/Display Installation Manual

FTP-1000 Touchpad/Display Installation Manual FTP-1000 Touchpad/Display Installation Manual A B 1 2 3 4 5 6 7 8 9 0 * # Stay Away Disarm Quick Exit C D P/N 466-2231 REV B January 2011 Copyright Disclaimer Trademarks and patents Manufacturer Intended

More information

FreezeAlarm Dialer FA-700 Installation and Operations Manual

FreezeAlarm Dialer FA-700 Installation and Operations Manual FreezeAlarm Dialer FA-700 Installation and Operations Manual Emerson Control Products Inc. 1724 Lake Drive West Chanhassen, MN 55317 Document No. 42420079B Table of Contents Cautions and warnings... 4

More information

Computer Room Guard Model VM Manual and Installation Instructions

Computer Room Guard Model VM Manual and Installation Instructions Computer Room Guard Model VM500-8 Manual and Installation Instructions For units purchased since December 2004 Index Page General Description 3 Installation, Wiring Diagram 3-5 Accessing the Computer Room

More information

2000 Series. Program Entry Guide. Control Panels

2000 Series. Program Entry Guide. Control Panels 2000 Series EN Program Entry Guide Control Panels 2000 Series Program Entry Guide About This Manual EN 2 About This Manual This guide describes the programming parameters available to the 2000 Series Control

More information

T7079A,B Solid State Remote Temperature Controllers

T7079A,B Solid State Remote Temperature Controllers T7079A,B Solid State Remote Temperature Controllers FEATURES PRODUCT DATA Switch selection of heat or cool mode. Temperature sensing up to 400 feet. Does not require field calibration. 0K NTC temperature

More information

FreezeAlarm Dialer Pro

FreezeAlarm Dialer Pro FreezeAlarm Dialer Pro User Manual for FA-800E Thank you for purchasing our FreezeAlarm Dialer Pro. This instruction manual covers installation for model FA-800E. General Description The FA-800E automatically

More information

D169 2-Way Voice Verification Module. Installation and Operating Manual Radionics 34105B 3/97

D169 2-Way Voice Verification Module. Installation and Operating Manual Radionics 34105B 3/97 D169 2-Way Voice Verification Module Installation and Operating Manual Notice The material and instructions covered in this manual have been carefully checked for accuracy and are presumed to be reliable.

More information

T6984 A,D,E Electronic Floating Control Thermostats

T6984 A,D,E Electronic Floating Control Thermostats T6984 A,D,E Electronic Floating Control Thermostats FEATURES PRODUCT DATA PI (proportional and integral) control action provides accurate, stable room temperature control. T6984 models are used with Series

More information

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96 Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96 XL-2G Gold Product Overview 7 Zones (6 programmable + panic or keyswitch zone) Fast Loop Response

More information

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE K3179V2 2/11 Rev. A ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE FEATURES The ADEMCO 4208SNF Universal Class A Module can be used in either of two different applications.

More information

AVS Audio Verification System

AVS Audio Verification System AVS Audio Verification System Installation and Setup Guide K14860-3V2 12/12 Rev. B Table of Contents GENERAL DESCRIPTION... 3 About the AVS...3 System Operation...4 Trigger Signal...4 Trigger Response

More information

HomeSitter HS-700 Installation and Operations Manual Emerson Control Products Inc Lake Drive West Chanhassen, MN Document No.

HomeSitter HS-700 Installation and Operations Manual Emerson Control Products Inc Lake Drive West Chanhassen, MN Document No. HomeSitter HS-700 Installation and Operations Manual Emerson Control Products Inc. 1724 Lake Drive West Chanhassen, MN 55317 Document No. 41410062C Table of contents Cautions and warnings... 4 Description...

More information

Fire Control/Communicator

Fire Control/Communicator Operation and Installation Manual Fire Control/Communicator 1 2 3 4 5 12V AC,20V A, 60Hz or +24V DC 12V AC, 20V A, 60Hz or -24V DC EARTH GND BATTERY - BATTERY + 6 INITIATING A1-7 INITIATING A2-8 INITIATING

More information

C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR

C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR PRODUCT DATA C7232A C7232B FEATURES Used for CO 2 based ventilation control. Models available with LCD that provides sensor readings and status information.

More information

Using your LED Plus keypad

Using your LED Plus keypad Part Number 5-051-372-00 Rev B Using your LED Plus keypad System 238 System 2316 System 238i System 2316i Thank you for purchasing this C&K alarm system Your system is one of the most powerful and advanced

More information

AXI LED USER MANUAL (REV. 1.0)

AXI LED USER MANUAL (REV. 1.0) Security & Home Automation System AXI LED USER MANUAL (REV. 1.0) CONTENTS PREFACE FEATURES LED KEYPAD OUTLOOK 1.0 LIGHT INDICATION 1 2 4 6 CHAPTER 1: ALARM SYSTEM CONTROL 1.0 USING LED KEYPAD 1.0.1 ARMING

More information

Operating Manual. Series Touchscreen Programmable Demand Control Thermostat. UtilityPRO TM

Operating Manual. Series Touchscreen Programmable Demand Control Thermostat. UtilityPRO TM Operating Manual UtilityPRO TM Series Touchscreen Programmable Demand Control Thermostat 85-3126 BE CAREFUL! Never use sharp instruments, such as a pencil or pen, to press touchscreen keys. To prevent

More information

T6572A, T6573A,B, T6992A,B, T6993B Digital Fan-Coil Thermostats

T6572A, T6573A,B, T6992A,B, T6993B Digital Fan-Coil Thermostats TA, TA,B, TA,B, TB Digital Fan-Coil Thermostats XE/XE00 SERES FEATURES PRODUCT DATA Attractive modern styling with digital display makes the thermostat ideal for offices or hotels. Hotel card key input

More information

F150E Media Air Cleaner

F150E Media Air Cleaner whole-house air quality system FEATURES F150E Media Air Cleaner PRODUCT DATA APPLICATION F150E W8600A AIRWATCH W8600A AIRWATCH filter change indicator. High efficiency media filter captures particles as

More information

Solid Core and Split Core Fixed Current Status Switches CSS-O,C; CSP-O,C -F (FIXED) SERIES

Solid Core and Split Core Fixed Current Status Switches CSS-O,C; CSP-O,C -F (FIXED) SERIES Solid Core and Split Core Fixed Current Status Switches CSS-O,C; CSP-O,C -F (FIXED) SERIES PRODUCT DATA FEATURES Solid and Split Core, Fixed Current go/no go switches. Very low operating trip points. LED

More information

L8005A,B; LS8005A,C,D Electronic Pool and Spa Controllers

L8005A,B; LS8005A,C,D Electronic Pool and Spa Controllers Electronic Pool and Spa Controllers The L8005A,B and LS8005A,C,D Electronic Pool and Spa Controllers are used in pool, spa, and hot tub applications to control water temperature. Remote Potentiometer L8005A,B

More information

T7300F Multistage Conventional or Heat Pump Programmable Commercial Thermostat

T7300F Multistage Conventional or Heat Pump Programmable Commercial Thermostat T7300F Multistage Conventional or Heat Pump Programmable Commercial Thermostat 1.0 GENERAL 1.1 Overview GUIDE SPECIFICATION The contractor shall furnish, install, and place in operating condition an HVAC

More information

PC4020 v3.2 Instruction Manual

PC4020 v3.2 Instruction Manual PC4020 v3.2 Instruction Manual WARNING: This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire

More information

MiniAlarm Plus. Model MA-5000

MiniAlarm Plus. Model MA-5000 MiniAlarm Plus 1 Model MA-5000 Thank you for purchasing the MiniAlarm Plus. We are confident this product will provide you with the peace of mind and protection you expect. If you should ever have any

More information

C7031D,G,J C7041B,C,D,F,J,K,P,R Series 2000 Electronic Temperature Sensors

C7031D,G,J C7041B,C,D,F,J,K,P,R Series 2000 Electronic Temperature Sensors C703D,G,J C70B,C,D,F,J,K,P,R Series 2000 Electronic Temperature Sensors PRODUCT DATA C703D, C70D C70B,C C70R C703G, C70F C70P FEATURES C703D, C70D for immersion mounting sense water temperature. C703G,

More information

Interrogator 200 Audio Verification Module (AVM)

Interrogator 200 Audio Verification Module (AVM) Interrogator 200 Audio Verification Module (AVM) Document Number: 466-1153 Rev. B July 1996 Audio Verification Module Use a maximum of 500 feet of cable for all speakers and microphones. For example, if

More information

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer. SK618 WIRELESS ALARM SYSTEM WITH AUTO DIALER OWNER'S MANUAL Thank you for choosing Ideal Security s Home Security System with Telephone Dialer. If at any time during your installation you have any questions

More information

Addressable NAC Output Module D327A

Addressable NAC Output Module D327A Installation Instructions Notice Addressable NAC Output Module D327A These instructions cover the installation of the D327A Addressable NAC Output Module in an analog system controlled by a Bosch D8024,

More information

IFT-RC150 IntelliFire Touch Remote Control Installation Instructions

IFT-RC150 IntelliFire Touch Remote Control Installation Instructions IFT-RC150 IntelliFire Touch Remote Control Installation Instructions Leave this manual with party responsible for use and operation. 1. Introduction The IFT-RC150 is a wall mounted device that is designed

More information

Long Range Radio Alarm Transmitter

Long Range Radio Alarm Transmitter TM Long Range Radio Alarm Transmitter INSTALLATION MANUAL Version 1.3W FEATURES Transmits alarm information to a long range radio network Varitech Transmission Format Note: If automatic SIA is used in

More information

ElkGuard. Owner's Manual. Self-Contained Wireless Security System. ElkGuard

ElkGuard. Owner's Manual. Self-Contained Wireless Security System. ElkGuard ElkGuard TM Self-Contained Wireless Security System ElkGuard Owner's Manual THIS MANUAL IS PROVIDED TO ACQUAINT YOU WITH THE OPERATION OF THE SYSTEM AND HELP YOU BECOME PROFICIENT WITH IT S OPERATION.

More information

FUTURE CALL. Loud Ringer Light Box FC OWNER S MANUAL AND OPERATING INSTRUCTIONS

FUTURE CALL. Loud Ringer Light Box FC OWNER S MANUAL AND OPERATING INSTRUCTIONS FUTURE CALL Loud Ringer Light Box FC-5683-2 OWNER S MANUAL AND OPERATING INSTRUCTIONS 1 IMPORTANT SAFETY INSTRUCTIONS Before using your telephone equipment, basic safety precautions should always be followed

More information

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad... 2 Contents Glossary...7 1. Introduction to the IDS805...8 1.1 Notes...8 2. Understanding the Keypad Indicators...8 3. Operation of the Keypad...9 4. System Information...10 4.1 Programmed Functions...10

More information

Contents. Glossary

Contents. Glossary Contents Glossary ------------------------------------------------------------------------------------------------------ 6 1. Introduction to the IDS 1632 -------------------------------------------------------------

More information

TABLE OF CONTENTS TABLE OF CONTENTS 1

TABLE OF CONTENTS TABLE OF CONTENTS 1 TABLE OF CONTENTS TABLE OF CONTENTS 1 FEATURES 2 Keypad Programmable... 2 EEPROM Memory... 2 Static/Lightning Protection... 2 Supervision... 2 Operation... 2 SPECIFICATIONS 2 PC1550 Control Panel... 2

More information

R E G E N C Y Model 2615 Control/Communicator. Installation Manual. Part Number , Rev. A Initial Release Date: March 1995 Revised August 1998

R E G E N C Y Model 2615 Control/Communicator. Installation Manual. Part Number , Rev. A Initial Release Date: March 1995 Revised August 1998 R E G E N C Y Model 2615 Control/Communicator Installation Manual Part Number 150863, Rev. A Initial Release Date: March 1995 Revised August 1998 Interactive Technologies, Inc. TE CHNO LO G IES Security

More information

OPERATING GUIDE FOR YOUR RP1054D KEYPAD

OPERATING GUIDE FOR YOUR RP1054D KEYPAD OPERATING GUIDE FOR YOUR RP1054D KEYPAD Napco 1992 DESIGN PATS. PENDING Technical Manuals Online! - http://www.tech-man.com CONGRATULATIONS!...on your purchase of a NAPCO Magnum Alert security system.

More information

Destiny Destiny Owners Manual

Destiny Destiny Owners Manual Destiny 4100 Destiny 4100 Owners Manual TABLE OF CONTENTS INTRODUCTION Control Panel...3 Detection Devices...3 Telephone Keypads...3 GLOSSARY... 4-5 LOCAL PHONE ACCESS Using Your Telephones As Keypads...6

More information

TYDOM 315. * _Rev.2* GSM domotics transmitter. 1. Presentation

TYDOM 315. * _Rev.2* GSM domotics transmitter. 1. Presentation TYDOM 5 GSM domotics transmitter ) Présentation. Presentation Delta Dore hereby declares that the equipment complies with the essential requirements and other relevant provisions of the R&TTE Directive

More information

Congratulations! This manual consists of four sections: SECTION 1 introduces you to the components of your CareTaker system.

Congratulations! This manual consists of four sections: SECTION 1 introduces you to the components of your CareTaker system. Congratulations! Your purchase of the CareTaker security system is a decision which will afford you greater peace of mind for the many years of service the system is designed to provide. The CareTaker

More information

INSTALLATION GUIDE XTLN-WIFI PANEL

INSTALLATION GUIDE XTLN-WIFI PANEL INSTALLATION GUIDE XTLN-WIFI PANEL MODEL XTLN-WiFi INSTALLATION GUIDE FCC NOTICE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of

More information

E N G L I S H SUPER PHONE RINGER MODEL SR-200 & SR-95 E S P A Ñ O L F R A N Ç A I S. Users Guide SR200 M52002 A 4/03

E N G L I S H SUPER PHONE RINGER MODEL SR-200 & SR-95 E S P A Ñ O L F R A N Ç A I S. Users Guide SR200 M52002 A 4/03 UPR PHO RGR MOD R-200 & R-95 G H P A Ñ O R200 M52002 A 4/03 Users Guide F R A Ç A Table Of Contents Operation..............3 afety nformation.........4 nstallation.............15 Warranty..............18

More information

SK642 THE TELEPHONE DIALER REQUIRES A LAND TELEPHONE LINE TO MAKE OUTGOING CALLS AND ELECTRICITY.

SK642 THE TELEPHONE DIALER REQUIRES A LAND TELEPHONE LINE TO MAKE OUTGOING CALLS AND ELECTRICITY. SK642 WIRELESS WATER ALARM SYSTEM WITH AUTO DIALER OWNER'S MANUAL AND SET UP INSTRUCTIONS. Thank you for choosing Ideal Security s Wireless Water Alarm with Telephone Dialer. Please read through complete

More information

Control/Communicator Installation Manual

Control/Communicator Installation Manual DAS NETWORX NX-12 Control/Communicator Installation Manual General Description...2 Ordering Information...2 Option Definitions...3 Programming the LED Code Pads...5 Programming the NX-12...9 Types of Programming

More information

Voice Dialer Temperature & Power Loss Monitor VD-5100-TM / VD-5101-TM

Voice Dialer Temperature & Power Loss Monitor VD-5100-TM / VD-5101-TM Innovative Technologies n Custom Electronic Design & Manufacturing General Description The VD-5100-TM (Fahrenheit) and VD-5101-TM (Celsius) Voice Dialer monitors temperature and power status. Upon an alarm

More information

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover TABLE OF CONTENTS FEATURES 2 SPECIFICATIONS 2 INSTALLATION 3 Mounting the Panel... 3 Mounting the Keypad... 3 Auxiliary Power Connection... 3 PGM Terminal Connections... 3 Bell/Siren Connection... 3 Keypad

More information

Personal Assistance System Owner s Manual

Personal Assistance System Owner s Manual Personal Assistance System Owner s anual 3 3 O UNT A C K G HOUS RCORD nstall Run AC Power Battery Low 4 2 8 3 6 PROG 0 RCORD Personal Assistance System PA800 RAD THS FRST This equipment generates and uses

More information

DESTINY 6100 SERIES SECURITY SYSTEM OWNER S MANUAL V1 12/01

DESTINY 6100 SERIES SECURITY SYSTEM OWNER S MANUAL V1 12/01 DESTINY 6100 SERIES SECURITY SYSTEM OWNER S MANUAL 800-6006V1 12/01 System Overview General Information Control Panel Detection Devices You have made a wise decision to protect your family and property

More information

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160 All-In-One Wireless Security System V3.2 Programming Guide Model # MG6130 / MG6160 We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com

More information

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions QUICK LINKS Mounting Location Guidelines Open the Sensor Mount the Sensor Sensor Components and Settings Wire the Sensor Wiring

More information

Operation and Installation Guide. Zone Expansion Module D8125

Operation and Installation Guide. Zone Expansion Module D8125 Operation and Installation Guide Zone Expansion Module D8125 Page 2 2004 Bosch Security Systems, Inc. Contents 1.0 Introduction...7 1.1 Guide Organization... 7 1.2 Other Literature Referenced... 7 1.3

More information

INSTALLATION MANUAL PC56O. Version 1.OA

INSTALLATION MANUAL PC56O. Version 1.OA INSTALLATION MANUAL PC56O Version 1.OA TABLE OF CONTENTS INTRODUCTION 3 Features... 3 Specifications... 3 INSTALLATION 4 Mounting the Control Panel... 4 Mounting the Keypad... 4 Wiring... 5 Burglary Zone

More information

United Security Products Model AVD-45b Automatic Voice Dialer Installation and Instruction Manual

United Security Products Model AVD-45b Automatic Voice Dialer Installation and Instruction Manual United Security Products Model AVD-45b Automatic Voice Dialer Installation and Instruction Manual Patents Pending INTRODUCTION Thank you for purchasing United Security Products Model AVD-45b, the single

More information

HP970 and TP970 Series Standard Covers and Accessories

HP970 and TP970 Series Standard Covers and Accessories HP970 and TP970 Series Standard Covers and Accessories FEATURES SPECIFICATION DATA Compact cover design for aesthetic appearance Available with or without setpoint opening for tamper resistance Satin chrome,

More information

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER BAT.LOW AC WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER THE SYSTEM THAT CALLS YOU! Our WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER is designed to allow you to create your own security system.

More information

Long Range Radio Alarm Transmitter

Long Range Radio Alarm Transmitter W A R N I N G Please refer to the System Installation Manual for information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. TM

More information

L900 series USER MANUAL

L900 series USER MANUAL INTRODUCTION The BLUGUARD Control Panel is designed for simple operation yet provides the maximum protection for you. Please read this manual carefully and follow the instructions contained in this book.

More information

T7100D Microelectronic Conventional Thermostat

T7100D Microelectronic Conventional Thermostat T7100D Microelectronic Conventional Thermostat INSTALLATION INSTRUCTIONS APPLICATION A. ENGAGE TABS AT TOP OF THERMOSTAT AND SUBBASE. The T7100D Microelectronic Thermostat provides electronic control of

More information

SENSAPHONE. Model User s Manual. Version 1.11 SENSAPHONE, INC.

SENSAPHONE. Model User s Manual. Version 1.11 SENSAPHONE, INC. SENSAPHONE Model 1104 User s Manual Version 1.11 SENSAPHONE, INC. Sensaphone Model 1104 User s Manual Every effort has been made to ensure that the information in this document is complete, accurate and

More information

SUMMIT USER MANUAL Software version 460 and above. Second Edition. Electronics Line (E.L.) Ltd. ZI0026A (11/97)

SUMMIT USER MANUAL Software version 460 and above. Second Edition. Electronics Line (E.L.) Ltd. ZI0026A (11/97) SUMMIT 3208 USER MANUAL Software version 460 and above. Second Edition Electronics Line (E.L.) Ltd. Notice: Electronics Line (E.L.) Ltd. reserves the right to change the information within this manual

More information

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS GENERAL DESCRIPTION... 2 STANDARD AND OPTIONAL PARTS LIST... 2 PARTS DIAGRAM... 3 TERMINAL DRAWING AND SPECIAL NOTES...

More information

SYSTEM ENHANCEMENT MODULE

SYSTEM ENHANCEMENT MODULE SYSTEM ENHANCEMENT MODULE DSC PowerSeries INSTALLATION GUIDE INSTALL WIZARD AVAILABLE AT ALARM.COM/SEMPOWERSERIES OVERVIEW The System Enhancement Module (SEM) can be used with DSC PowerSeries PC1616, PC1832,

More information

Installation Guide. Control/Communicator

Installation Guide. Control/Communicator Installation Guide Control/Communicator 33120G Page 2 Copyright 2001 Radionics Contents 1.0 Introduction... 5 1.1 Listings and Approvals... 5 1.1.1 Fire... 5 1.1.2 Burglary... 5 1.2 FCC Notice... 5 1.2.1

More information

DESTINY OWNER S MANUAL

DESTINY OWNER S MANUAL DESTINY OWNER S MANUAL DESTINY You have made a wise decision to protect your family and property with the DESTINY Security System. The DESTINY has been designed to provide you with a maximum level of security

More information

Hazardous Area Ringdown Telephone

Hazardous Area Ringdown Telephone Industrial Communications Worldwide Hazardous Area Ringdown Telephone Model EP701 Installation & Operation 7552-10th Street N.E. Calgary, Alberta, Canada T2E 8W1 Ph: 403.258.3100 \ email:info@guardiantelecom.com

More information

Security System. User Guide for the LED Command Center

Security System. User Guide for the LED Command Center Security System User Guide for the LED Command Center National Security Systems Inc (800)457-1999 MY SECURITY COMPANY IS: CALL BEFORE TEST: THIS SECURITY SYSTEM IS CONNECTED TO TELEPHONE NUMBER: THE SECURITY

More information