1 LED Emergency Battery Backup Installation Instructions Ordering Code: PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION: TROFFER INSTALLATION STRIP INSTALLATION
2 INTRODUCTION & TABLE OF CONTENTS Ordering Code : (23W V QC WH) is compatible with all Litetronics 0-10V dimmable Retrofits. It is also usable with Litetronics non-dimmable Retrofits up to 23 Watts. Congratulations on the purchase of your Emergency Battery Backup. It is usable for a range of installations. We have included some of the most common ones here. Section 1- TROFFER OR WRAP INSTALL 4 Section 2- STRIP FIXTURE INSTALL 7 Section 3- MISCELLANEOUS OPERATING INSTRUCTIONS 10 Section 4- WIRING DIAGRAM A (For 0-10V LED Retrofit with dimmer) 11 WIRING DIAGRAM B (For 0-10V LED Retrofit with or without switch and without dimmer) 12 WIRING DIAGRAM C (For non-dim LED Retrofit <23W with or without switch) 13 SAFETY INSTRUCTIONS AND WARNINGS WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING: READ AND FOLLOW ALL SAFETY INSTRUCTIONS. Do not use outdoors. Do not let power supply cords touch hot surfaces. Do not mount near gas or electric heaters. Use caution when servicing batteries. Battery acid can cause burns to skin and eyes. If acid is spilled on skin or in eyes, flush acid with fresh water and contact a physician immediately. Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition. Do not use this equipment for other than intended use. Installation should be in accordance with NEC and any relevant local codes. Risk of fire or electric shock. Emergency Battery Backup installation requires knowledge of electrical system. If not qualified, do not attempt installation. Contact a qualified electrician. Risk of fire or electric shock. Luminaire wiring and electrical parts may be damaged when drilling for installation of Emergency Battery Backup. Check for enclosed wiring and components. This Emergency Battery Backup shall only be installed into an UL/CUL Listed Luminaire with a steel enclosure. DO NOT INSTALL THIS EMER- GENCY BATTERY BACKUP INTO LUMINAIRES WITH NON-FERROUS METAL OR POLYMERIC ENCLOSURES To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. Voltage could be present in Battery. To prevent high voltage from being present on output leads, Battery connector must be open. Do not connect Battery connector until installation is complete. Make sure that the necessary branch circuit wiring is available. An un-interrupted AC source of power is required. THIS PRODUCT CONTAINS A RECHARGEABLE Ni-MH BATTERY. THE BATTERY MUST BE RECYCLED OR DISPOSED OF PROPERLY. In all installations, with or without a dimmer, the wires labeled 0-10V Retrofit or Luminaire must be connected to the Retrofit or Luminaire 0-10V wires before power is restored. DISCONNECT SAFETY INSTRUCTIONS Improperly installed electrical wiring can be dangerous and cause electrical fires. This product must be used in accordance with the current rating and wire sizes listed. Consult local building code before doing any electrical work. COPPER to COPPER ONLY. Do not use on Aluminum. Temperature rating: 105 C (221 F) maximum. Flame Rated UL94V-0. Can be used with and without a switch. Battery is replaceable with Litetronics s ordering code EBA45-12V. Contact the manufacturer for information on replacement battery. Easy front access to Dip Switch for adjustments to control output power of 23 watts for 0-10V to various LED retrofit models Compatible with non-dimmable LED Retrofit 120V-277V up to 23W with full power light output. Do not use with non-dimmable 32W or 50W or more than 23W LED retrofit. SAVE THESE INSTRUCTIONS 2
3 12 13 RETROFIT COMPATABILITY TABLE is compatible with all Litetronics 0-10V dimmable Retrofits. It is also usable with Litetronics non-dimmable Retrofits up to 23 Watts. DIMMABLE ORDERING CODE DESCRIPTION WATTS RF50UQT4XXDL 0-10V 50W 3-2x4 LED RF QC 50W RF32UQT4XXDL 0-10V 32W 2-2x4 LED RF QC 32W RF32UQT1XXDL 0-10V 32W 2-1X4 LED RF QC 32W RF32UQT2XXDL 0-10V 32W 3-2X2 LED RF QC 32W RF16UQT1XXDL 0-10V 16W 1-1X4 LED RF QC 16W RF16UQT1XXCDL 0-10V 16W 1-1X4 LED RF 16W (2) RF32UQT1XXCDL (2) 0-10V 32W 2-1X4 LED RF QC 64W (2) RF16UQT1XXCDL (2) 0-10V 16W 1-1X4 LED RF QC 32W RF32UQT1XXCDL 0-10V 32W 2-1X4 LED RF QC 32W RF32UHT1XXDL 0-10V 32W 2-1X4 LED RF QC 32W NON-DIMMABLE ORDERING CODE DESCRIPTION WATTS RF16UQT1XXC 16W 1-1X4 LED RF QC 16W RF22UQT2XX 22W 2-2X2 LED RF QC 22W What comes in the box: To Switch Line (1) Female Quick Disconnect (Attached to Male End) (1) Male Quick Disconnect (Attached to Female End) 0-10V Retrofit or Luminaire (Note: Dimmer connection wires are inside box) (2) Self-tapping screws, #8 x 1/2 Green Light Indicator Emergency Battery Backup with Magnets Test Switch (5)Wire Nuts AVAILABLE ACCESSORIES Emergency battery backup from Litetronics comes with a rechargeable battery installed. Replacement batteries are also available for purchase. Battery accessory (EBA45-12V) 3
4 Section 1 TROFFER FIXTURE INSTALL 1. Turn off power at circuit breaker. Open the cover of the existing fixture. 2. Remove lid of emergency battery backup by unscrewing 2 screws. 3. Check the corresponding LED RetroFit model number. Use below table to select and change dip switch position for setup. In factory default setting, Position 2 set to ON. You should set all dip switch positions to OFF, unless a position is specified as ON for your Retrofit model. DIP SWITCH SETUP FOR LITETRONICS RETROFIT MODEL NUMBER EMERGENCY OUTPUT WATTS DIP SWITCH POSITION RF16UQT1XXC 16W RF22UQT2XX 22W RF16UQT1XXDL 16W RF16UQT1XXCDL 16W (2) RF16UQT1XXCDL 23W ON RF32UQT1XXDL 23W ON RF32UQT1XXCDL 23W ON (2) RF32UQT1XXCDL 23W ON RF32UHT1XXDL 23W ON RF32UQT2XXDL 23W ON RF32UQT4XXDL 23W ON RF50UQT4XXDL 23W ON CAUTION:IF DIP SWITCH IS MIS-CONFIGURED, i) Damage to the emergency battery backup will occur. ii) Backup battery time will be less than 90 minutes and brightness will be less than specified. 4
5 Section 1 TROFFER FIXTURE INSTALL 4. Place emergency battery backup on fixture and position as needed. Recommended placement is close to the junction box of LED RetroFit and input power wires. 5. Unscrew junction box cover of existing RetroFit from luminaire troffer. 6. For electrical connections, refer to the wiring diagrams on pages 11,12 and 13. Note: In all installations, with or without a dimmer, the jacketed wires labeled 0-10V Retrofit or Luminaire must be connected to the Retrofit or luminaire 0-10V dimmer control wires before power is restored. 7. Secure emergency battery backup with two of the selftapping screws provided. The holes are located inside on the bottom frame of case. 8. Connect halves of white multi-pin battery connector together. 5
6 Section 1 TROFFER FIXTURE INSTALL 9. Replace lid back on of emergency battery backup and secure with 2 screws. 10. Replace junction box (from step 4) over remaining wires, and secure with screws. 11. Close the cover, restore the power. 6
7 Section 2 STRIP FIXTURE INSTALL 1. Turn off power at the circuit breaker. Open the cover of the existing fixture. 2. Remove lid of emergency battery backup by unscrewing 2 screws. You will not need to replace the cover for this installation. 3. Remove push button tester and LED indicator with LED holder from their positions in the metal box wall. 4. Place emergency battery backup in strip fixture and position as needed. Recommended to place close to the LED RetroFit and input power wires. Extend wires for push button tester and LED indicator from unit. Mark position for emergency battery backup and holes in strip fixture wall. Remove backup. 5. Drill two holes in strip fixture wall for the LED indicator light 1/4 (6.3mm) and push button tester 9/32 (7.2mm). Replace emergency backup kit. 7
8 Section 2 STRIP FIXTURE INSTALL 6. Insert the LED indicator light through hole in the side of strip and secure with LED holder. 7. Insert the push button tester through hole in the side of strip. Secure with lock washer and nut. 8. Check the corresponding LED RetroFit model number. Use below table to select and change dip switch position for setup. In factory default setting, Position 2 set to ON. You should set all dip switch positions to OFF, unless a position is specified as ON for your Retrofit model. DIP SWITCH SETUP FOR LITETRONICS RETROFIT MODEL NUMBER EMERGENCY OUTPUT WATTS DIP SWITCH POSITION RF16UQT1XXC 16W RF22UQT2XX 22W RF16UQT1XXDL 16W RF16UQT1XXCDL 16W (2) RF16UQT1XXCDL 23W ON RF32UQT1XXDL 23W ON RF32UQT1XXCDL 23W ON (2) RF32UQT1XXCDL 23W ON RF32UHT1XXDL 23W ON RF32UQT2XXDL 23W ON RF32UQT4XXDL 23W ON RF50UQT4XXDL 23W ON CAUTION:IF DIP SWITCH IS MIS-CONFIGURED, i) Damage to the emergency battery backup will occur. ii) Backup battery time will be less than 90 minutes and brightness will be less than specified. 8
9 Section 2 STRIP FIXTURE INSTALL 9. Secure emergency battery backup to strip fixture with two of the self-tapping screws. The holes are located inside on the bottom frame of case. 10. For electrical connections, refer to the wiring diagrams on pages 11,12 and 13. Note: In all installations, with or without a dimmer, the jacketed wires labeled 0-10V Retrofit or Luminaire must be connected to the Retrofit or luminaire 0-10V dimmer control wires before power is restored. 11. Connect halves of white multi-pin battery connector together. 12. You do not need to replace the cover on the emergency backup. The strip fixture cover is all that is required. 13. Close the cover, restore the power. 9
10 ion 2 Section 3 MISCELLANEOUS OPERATING INSTRUCTIONS TEST/OPERATION: 1. When AC power is applied, charge indicator light illuminates green. That indicates the battery is charging. 2. Press button PUSH to TEST for 3 seconds to simulate power failure and confirm LED RetroFit is functioning in emergency mode. Charge indicator light will be off. 3. When power fails, the emergency battery backup automatically switches to emergency power. The charge indicator light is off and the RetroFit will operate at about 23W. 4. When AC power is restored, the emergency battery automatically returns to charge mode. 5. must be charged for 24 hours before 90 minute test can be completed. MAINTENANCE: Although no routine maintenance is required to keep the emergency battery backup functional, it should be checked periodically to ensure that it is working. The following schedule is recommended: 1. Visually inspect the charge indicator light monthly. It should be illuminated. 2. Test the emergency operation of the fixture at 30-day intervals for a minimum of 30 seconds. 3. Conduct a 90-minute discharge test once a year. LED tubes should operate at about 23W for at least 90 minutes. SERVICE: Should be performed as indicated above by qualified personnel. 10
11 Section 4 WIRING DIAGRAM A 0-10V LED Retrofit with dimmer. Connect wires as outlined. Follow wiring diagram A below: a. Connect purple (+) and gray(-) coming out of emergency backup to purple (+) and gray (-) from LED RetroFit using wire nuts. b. Connect yellow (+) and gray(-) wires wrapped in emergency backup to purple (+) and gray (-) from LED dimmer using wire nuts. c. Plug Out-N (white) and Out-L (black/white) of emergency backup connector with LED RetroFit together. d. Connect AC-N (white) and AC-L (black) of emergency backup to un-interrupted power supply wires. e. Connect SW (red) coming out of emergency backup to dimmer. AC-N / AC-L / SW 0-10V Retrofit or Luminaire Dim (+) / Retrofit or Luminaire Dim (-) OUT-N / OUT-L NOTE: 0-10V dimmer wires inside A. 0-10V LED RETROFIT WITH DIMMER LINE (HOT) NEUTRAL WHITE HOT UNINTERRUPTED BLACK RED AC-N AC-L SW # 0-10V DIMMER YELLOW GRAY PURPLE GRAY 0-10V DIMMER (+) 0-10V DIMMER 0-10V DIMMER (-) WIRES INSIDE 0-10V RETROFIT OR LUMINAIRE DIM (+) 0-10V RETROFIT OR LUMINAIRE DIM (-) LED EMERGENCY BATTERY BACKUP WHITE BLACK/WHITE OUT-N OUT-L LED RETROFIT (0-10V) # FOLLOW DIMMER INSTRUCTION MANUAL FOR CONNECTION 11
12 Section 4 WIRING DIAGRAM B 0-10V LED Retrofit with switch and without dimmer. Connect wires as outlined. Follow wiring diagram B(i) below: a. Connect purple (+) and gray(-) coming out of emergency backup to purple (+) and gray (-) from LED RetroFit using wire nuts. b. Cover the yellow (+) and gray (-) coming out of emergency backup with wire nuts. c. Plug Out-N (white) and Out-L (black/white) of emergency backup connector together with LED RetroFit. d. Connect AC-N (white) and AC-L (black) of emergency backup to un-interrupted power supply wires. e. Connect SW (red) coming out of emergency backup to switch. 0-10V LED Retrofit without switch and without dimmer. Connect wires as outlined. Follow wiring diagram B(ii) below: a. Connect purple (+) and gray(-) coming out of emergency backup to purple (+) and gray (-) from LED RetroFit using wire nuts. b. Cover the yellow (+) and gray (-) coming out of emergency backup with wire nuts. c. Plug Out-N (white) and Out-L (black/white) of emergency backup connector together with LED RetroFit. d. Connect AC-N (white) and AC-L (black) of emergency backup to un-interrupted power supply wires. e. Connect AC-L (black) and SW (red) together. B. (i) 0-10V LED RETROFIT WITH SWITCH AND WITHOUT DIMMER WHITE HOT UNINTERRUPTED BLACK RED AC-N AC-L SW * * YELLOW GRAY PURPLE 0-10V DIMMER (+) 0-10V DIMMER (-) 0-10V DIMMER WIRES INSIDE 0-10V RETROFIT OR LUMINAIRE DIM (+) LED EMERGENCY BATTERY BACKUP GRAY 0-10V RETROFIT OR LUMINAIRE DIM (-) WHITE OUT-N BLACK/WHITE OUT-L LED RETROFIT (0-10V) B. (ii) 0-10V LED RETROFIT WITHOUT SWITCH AND WITHOUT DIMMER FOLLOW WIRING DIAGRAM B (i) BUT CONNECT AC-L (BLACK) AND SW (RED) TOGETHER. 12
13 Section 4 WIRING DIAGRAM C C.(i) For wiring non-dim LED Retrofit <23W with switch. Connect wires as outlined. Follow wiring diagram C(i) below: a. Cover both the purple (+) and gray (-) coming out of emergency backup with 2 wire nuts. b. Cover the yellow (+) and gray (-) coming out of emergency backup with 2 wire nuts. c. Plug Out-N (white) and Out-L (black/white) of emergency backup connector with LED RetroFit together. d. Connect AC-N (white) and AC-L (black) of emergency backup to un-interrupted power supply wires. e. Connect SW (red) coming out of emergency back up to switch C.(ii) For wiring non-dim LED Retrofit <23W without switch. Connect wires as outlined. Follow wiring diagram C(ii) below: a. Cover the purple (+) and gray (-) coming out of emergency backup with 2 wire nuts. b. Cover the yellow (+) and gray (-) coming out of emergency backup with 2 wire nuts. c. Plug Out-N (white) and Out-L (black/white) of emergency backup connector together with LED RetroFit. d. Connect AC-N (white) and AC-L (black) of emergency backup to un-interrupted power supply wires. e. Connect AC-L (black) and SW (red) coming out of emergency backup together. WIRING DIAGRAM C C. (i) NON-DIM LED RETROFIT <23W WITH SWITCH WHITE HOT UNINTERRUPTED BLACK AC-N AC-L * RED SW * * * * YELLOW GRAY PURPLE GRAY 0-10V DIMMER (+) 0-10V DIMMER (-) 0-10V DIMMER WIRES INSIDE 0-10V RETROFIT OR LUMINAIRE DIM (+) 0-10V RETROFIT OR LUMINAIRE DIM (-) LED EMERGENCY BATTERY BACKUP WHITE OUT-N BLACK/WHITE OUT-L LED RETROFIT (NON-DIM) C. (ii) NON-DIM LED RETROFIT <23 WITHOUT SWITCH FOLLOW WIRING DIAGRAM C (i) CONNECT AC-L (BLACK) AND SW (RED) TOGETHER 13
14 Thank you for choosing 6969 W. 73rd Street Bedford Park, IL or vol.10 ( )
LED Emergency Battery Backup Installation Instructions Ordering Code: EB23UQ
LED Emergency Battery Backup Installation Instructions Ordering Code: EB23UQ PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION SAFETY INSTRUCTIONS AND WARNINGS WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY
More information1 x4 Dimmable LED RetroFits
1 x4 Dimmable LED RetroFits Installation Instructions Ordering Code: RF16UQT1XXCDL RF16UHT1XXDL RF32UQT1XXCDL RF32UHT1XXDL PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION OF THE FOLLOWING: 4 STRIP FIXTURES
More informationInstallation Instructions
Installation Instructions Ordering Code: RF16UQT1XXC RF32UQT1XXC RF32UHT1XX RF45UQT1XXC RF45UHT1XX PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION OF THE FOLLOWING: 4 STRIP FIXTURES 8 STRIP FIXTURES
More informationInstallation Instructions
Installation Instructions Ordering Code: RF32UQT1XX PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION OF THE FOLLOWING: 4 STRIP FIXTURES 8 STRIP FIXTURES HARDWIRE 4 STRIP FIXTURES WRAP FIXTURES TROFFER
More informationLED Flat Panel Retrofit
LED Flat Panel Retrofit Installation Instructions For 2 x2, and 2 x4 LED Flat Panel Retrofits (RP Series) PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION INTRODUCTION The LED Flat Panel Retrofit fits
More informationI-320 SERIES AC EMERGENCY LIGHTING EQUIPMENT
P.O. BOX 84 TUCSON, AZ 85734 (520) 294-3292 FAX (520) 74-2837 www.iotaengineering.com INSTRUCTION MANUAL IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Flow Lighting QuickLED NEW FIXTURE 2x4 2x2 1x4 Corporate 1240 Texan Trail, Suite 102 Grapevine, TX 76051 (817)435-8484 Office www.flowledlighting.com READ AND FOLLOW ALL SAFETY
More informationMODEL RLY-DIM-D INSTALLATION INSTRUCTIONS
MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS IMPORTANT SAFEFGUARDS WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED. THESE INCLUDE: READ AND FOLLOW ALL SAFETY INSTRUCTIONS
More informationMODEL LUT-ATS-D (EPC-D-F-ATS) INSTALLATION ! IMPORTANT SAFEGUARDS!
MODEL LUT-ATS-D (EPC-D-F-ATS) INSTALLATI! IMPORTANT SAFEGUARDS! WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING: READ AND FOLLOW ALL SAFETY INSTRUCTIS
More informationCDL8 LED Architectural
Project: Type: Model# CDL8 LED Architectural PRODUCT DESCRIPTION Retrofit Down lights The Luminoso 8 inch Commercial LED Downlight is damp rated, and suitable for 1-277V Input equipped with fire-rated
More informationCold Door 2 LED Retrofit Kit Lighting System
PAGE 1 OF 6 General Information Cold Door 2 is intended for use inside commercial refrigeration cases with packed foods only. Cold Door 2 LED luminaire should only be used with SloanLED 100 Watt 24 VDC
More informationDioluce Products Installation Instructions
Dioluce Products Installation Instructions Models DL-R24-4530-5K0-001 DL-R24-4530-5K0-002 DL-R24-5035-5K0-001 DL-R24-5035-5K0-002 DL-R24-4530-4K0-001 DL-R24-4530-4K0-002 DL-R24-5035-4K0-001 DL-R24-5035-4K0-002
More informationMODEL EPC-D-F-ATS INSTALLATION INSTRUCTIONS ! IMPORTANT SAFEGUARDS!
MODEL EPC-D-F-ATS INSTALLATI INSTRUCTIS! IMPORTANT SAFEGUARDS! WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING: READ AND FOLLOW ALL SAFETY INSTRUCTIS
More informationAlbeo TM LED Luminaire Accessory (Emergency Battery Backup Module)
E Lighting Installation uide Albeo TM LED Accessory (Emergency attery ackup Module) EFOE YOU EI ead these instructions completely and carefully. ead and follow appropriate Lumination LED Installation uide
More informationDo not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
LED Tube Lamp (Linear Fluorescent Replacement) Retrofit Installation Instructions The product package includes the following components: 1. Integral LED Lamp (1 unit) 2. Fixture Warning Label (1 - self-adhesive)
More informationBACKUP BATTERY INSTALLATION INSTRUCTIONS
www.tiltlights.com BACKUP INSTRUCTIONS A Lauren International Company www.laurenillumination.com 855 440 8458 LdPE7-2014 SELf-TESTINg EmERgENCY LEd driver RATINGS: Input: 100-277 VAC 50 or 60 Hz Output:
More informationMaxLite LED High Bay Fixtures
General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions
More informationSERVICE BY QUALIFIED PERSONNEL ONLY
Installation Instructions Automatic Load Control Relay For Emergency Lighting! IMPORTANT SAFEGUARDS! WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING:
More informationMaxLite LED Round Pendant Highbay Series
General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions
More informationINSTALLATION INSTRUCTIONS - POWER SENTRY CONTROL POWER SENTRY CONTROL UNIT PSBCEB2 INSTALLATION INSTRUCTIONS
POWER SENTRY CONTROL UNIT PSBCEB2 INSTALLATION INSTRUCTIONS READ AND FOLLOW THESE INSTRUCTIONS BEFORE INSTALLATION TO ENSURE PROPER AND SAFE OPERATION SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL SAFETY
More informationInstallation Instructions
ELCU-200 Control Unit Circle CUT-OUT R8.5 mm Push to Test Specifications Cir.# Remote Activation Voltages... 120/277VAC 50/60Hz Max Load Requirements Ballast... 20A @120/277VAC Incandescent... 10A @120VAC
More informationCold Deck Canopy and Shelf Lights and Retrofit Kit
PAGE 1 OF 8 General Information Cold Deck LED lighting systems are intended for use inside of commercial refrigerated display merchandisers for food zone, splash zone, and non-food zones only. Cold Deck
More informationBdl60u Fluorescent Emergency Ballast
A Division Of Philips Electronics North America Corporation One- or two-lamp emergency; Universal input voltage: 120 through 277 V, 50 or 60 Hz; Replaces B60U Bdl60u Fluorescent Emergency Ballast Product
More informationFHSAC1-UNV-40L INSTALLATION INSTRUCTIONS
LED Driver with integrated emergency backup Universal Voltage: 120-277V ~, 50/60Hz Output Wattage: 40W Max. Output Current: 250-1400mA Linear Case with side leads Output voltage range of 11-55V This Driver
More informationESRB and ESRN Installation & Safety Instructions
B1784 ESRB and ESRN Installation & Safety Instructions IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS FHSKIT-T04LNX or FHSKIT-TXXXHX TABLE OF CONTENTS 1.0 INSTALLATION INSTRUCTION WARNINGS... PAGE 3 2.0 ORIGINAL FIXTURE PARTS... PAGE 4 3.0 HOTSPOT LED KIT PARTS... PAGE 5-6 4.0
More information1 General Description
1 General Description LED Tube Light adopts the new type LED as the light source, using the standard TB tube's end caps, makes it easy to install and replace the traditional fluorescent lamp. The TRF-51894
More informationILB-CP TBTS B MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED Patented. See iotaengineering.com/patents for more details
P.O. BOX 11846 TUCSON, AZ 85734 (520) 294-3292 FAX (520) 741-2837 www.iotaengineering.com INSTRUCTION MANUAL IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always
More informationCold Deck FIT. Canopy and Shelf Lights and Retrofit Kit. Installation Guide for General Information. Tools and Accessories Recommended
General Information Cold Deck FIT LED lighting systems are intended for use inside of commercial refrigerated display merchandisers for food zone, splash zone, and non-food zones only. Cold Deck FIT LED
More informationDHL-LP-LED Low Profile LED Linear High/Low Bay
IMPORTANT SAFETY INSTRUCTIONS To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions
More informationIMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions
HZM-Series-Class I, Div 2 Battery Unit HZM-Series-Class I, Div 2 Battery Unit Instalation instructions IMPORTANT SAFEGUARDS 1 4 5 6 7 13 When using electrical equipment, basic safety precautions should
More informationINSTALLATION INSTRUCTIONS - PS1055LCP & PS1555LCP LED EMERGENCY DRIVER PS1055LCP & PS1555LCP
LED EMERGENCY DRIVER PS1055LCP & PS1555LCP INSTALLATION INSTRUCTIONS READ AND FOLLOW THESE INSTRUCTIONS BEFORE INSTALLATION TO ENSURE PROPER AND SAFE OPERATION SAVE THESE INSTRUCTIONS LED EMERGENCY DRIVER
More informationINSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:
ILB-CP20-HE-A TBTS HIGH EFFICIENCY EMERGENCY LIGHTING EQUIPMENT FOR LED INSTRUCTION MANUAL IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including
More informationMaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights
General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions
More informationRAZOR RZR SERIES DIE CAST ALUMINUM LED EXIT SIGNS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS
RAZOR RZR SERIES DIE CAST ALUMINUM LED EXIT SIGNS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including
More informationSAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
ZR Series Commercial Specification Troffers with Emergency Driver Includes: ZR14, ZR22 and ZR24 IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed
More informationILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED
P.O. BOX 11846 TUCSON, AZ 85734 (520) 294-3292 FAX (520) 741-2837 www.iotaengineering.com INSTRUCTION MANUAL IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always
More informationARTEMIS Series of Low Occupancy LED Ceiling Mounted Fixtures (Including Stairwells) Installation & Operation Guide
Low Occupancy Fixture XL Stairwell Fixture XS 1 Please read these instructions carefully, and keep them for future reference. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions
More informationIMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions
3LERHZ Series Class I, Div 2 Combo Unit Installation instructions 3LERHZ Series Class I, Div 2 Combo Unit IMPORTANT SAFEGUARDS 1 3 When using electrical equipment, basic safety precautions should always
More informationUSER GUIDE & INSTALLATION INSTRUCTIONS
HARVESTEDGE TM THE NEW STANDARD IN LINEAR LED TOPLIGHT USER GUIDE & INSTALLATION INSTRUCTIONS Designed & Manufactured in Austin, TX illumitex.com 888.657.3520 THE DIGITAL HORTICULTURE COMPANY ref EDG.INST.9.2018.v2
More informationGTD20A Installation Instructions BRANCH CIRCUIT TRANSFER SWITCH/LIGHTING CONTROL DEVICE
Installation Instructions BRANCH CIRCUIT TRANSFER SWITCH/ CONTROL DEVICE UL 1008-BCELTS UL 924-Switch Bypass! IMPORTANT SAFEGUARDS! WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS
More informationILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED
P.O. BOX 11846 TUCSON, AZ 85734 (520) 294-3292 FAX (520) 741-2837 www.iotaengineering.com ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED Patented. See iotaengineering.com/patents for
More informationHighLINER 2. General Information: FOR YOUR SAFETY. Installation Guide for C1I75, L1C1I75, C2I75, L135C2I75
General Information: is intended for linear lighting in storerooms, walk-in coolers, indoor and outdoor soffits, outdoor canopies, car washes, and a variety of other lighting applications. Do not mount
More informationHoneywell Durafit LED Retrofit Kit
Honeywell Durafit LED Retrofit Kit INSTALLATION INSTRUCTIONS LED RETROFIT LUMINAIRE CONVERSION FOR USE ONLY WITH PRODUCTS DESCRIBED AND INSTALLED IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED WITH THIS
More informationCCS-100. Installation Manual
Installation Manual CCS-100 WARNING: DO NOT ATTEMPT TO INSTALL USE THE FIXTURE WITHOUT READING THE INSTALLATION INSTRUCTIONS AND SAFETY LABELS COMPLETELY. Failure to adhere to these instructions could
More informationInstallation Instructions
Fixture Mount Night Light Controller SPECIFICATIONS Power.....................................120VAC, 60Hz Relay Type..................................Form C, N.O. Load Requirements @120VAC......................................500W..........................
More informationLED IMPORTANT SAFETY INSTRUCTIONS
LED IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION To reduce the risk of death, personal injury or property damage
More informationMaxLite Polygon Linear LED Light
General Safety Information For Contractors: WARNING: Light fixtures should only be installed by qualified electricians. Be sure to use proper mounting method and hardware rated for the weight of the light
More informationMAXLITE RKT LED Retrofit Kit
Operating Instructions MAXLITE RKT LED Retrofit Kit Description and Intended Use The RKT LED Retrofit Kit is a high performance LED Fixture upgrade kit designed to replace the original components inside
More informationIMPORTANT SAFETY INSTRUCTIONS:
Online: www.ballarddesigns.com PRODUCT NAME: Stella Faceted Pendant ITEM NUMBER: LR007 DIMENSIONS OF ITEM ASSEMBLED: 13.5 D x 16.5 H IMPORTANT SAFETY INSTRUCTIONS: -A licensed professional electrician
More informationFluid Round Large 700 FMFLDRL_
Installation Instructions for Fluid Round Large 700 FMFLDRL_ 90FLUIDRL.0 CEILING COLLECTION GENERAL PRODUCT I NFORMATION: This product can mount to either a " square electrical box with round plaster ring
More information2018 PRODUCT CATALOG INNOVATION. SIMPLIFIED.
2018 PRODUCT CATALOG INNOVATION. SIMPLIFIED. INNOVATION. SIMPLIFIED. Creating better solutions Since 1970 For almost 50 years, we ve focused on developing lighting that is easier to use, better looking,
More informationElectric Fireplace. Electric Fireplace
Electric Fireplace Instruction Manual Wall Hanging Electric Fireplace Packing List 2 Electric Fireplace Glass Face Remote Control AAA Batteries Instruction Manual Wall Fixing Plate Fastener Package Yosemite
More informationMLLG-DE-LED-CHAN Installation Guide IMPORTANT SAFETY INSTRUCTIONS
MLLG-DE-LED-CHAN Installation Guide IMPORTANT SAFETY INSTRUCTIONS To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards
More informationFillmore Small Pendant Assembly and Installation Instructions
CAUTION: Fillmore Small Pendant Assembly and Installation Instructions BEFORE INSTALLING FIXTURE, MAKE SURE THE POWER TO THE CIRCUIT IS TURNED OFF AT THE MAIN FUSE BOX / CIRCUIT BREAKER UTILITY BOX. Important
More informationManifold Installation Controller MIC-180. Installation and Operation Instructions
Manifold Installation Controller MIC-180 Installation and Operation Instructions For Use With Rheem-Ruud and Paloma Commercial Tankless Water Heaters Table of Contents Safety Information... 1-2 Manifold
More informationIMPORTANT SAFETY INSTRUCTIONS:
PRODUCT NAME: Hadley 4 Light Pendant ITEM NUMBER: LC813 DIMENSIONS OF ITEM ASSEMBLED: Small: 18 1/2 H x 11 Square Large: 25 H x 16 Square IMPORTANT SAFETY INSTRUCTIONS: -A licensed professional electrician
More informationE2 Indirect/Direct Linear Recycling Luminaire Disassembly Instructions
Recycling Luminaire Disassembly Instructions Luminaire breaks down easily for recycling at the end of usable life*. Top Diffuser Top LED Boards Backplate Retention Collar and Set Screw Underlap Backplate
More informationMANUFACTURED IN THE UK
The Mini-Max range of energy efficient bulkhead fittings are manufactured with a polycarbonate base and diffuser. Together with a poured gasket the Mini-Max leads vandal-resistant IP65 technology. With
More informationUSER GUIDE & INSTALLATION INSTRUCTIONS
DESIGNED BY SCIENTISTS. BROUGHT TO LIFE BY ENGINEERS. USER GUIDE & INSTALLATION INSTRUCTIONS 5 7 Designed & Manufactured in Austin, TX illumitex.com 512.279.5020 DIGITAL HORTICULTURE + LED LIGHTING ref
More informationPME. Series Enclosures. Battery Enclosure (BE) Field Upgrade Installation Instructions. Effective: January, Alpha Technologies
PME Series Enclosures Battery Enclosure (BE) Field Upgrade Installation Instructions Effective: January, 2004 Alpha Technologies Power Alpha Technologies. Protecting The Power in Communications. Preface
More informationBasic Specifications to Install Tresco Lights Basic Specifications to Install Tresco Lights With With a HArDWIre a HARDWIRE To turn all s on/off at th
Basic Specifications to Install Tresco Lights Basic Specifications to Install Tresco Lights With With a PLug-In a PLUG-IN To control each individually, use Option 1. To control all s at the same time,
More informationInnovative Lighting R-Series Overhead LED Conversion Kits
Installation Guide Innovative Lighting R-Series Overhead LED Conversion Kits For Commercial Walk-In Coolers and Freezers BEFORE YOU BEGIN INSTALLATION Read these instructions carefully. Failure to follow
More informationDimmable LED Retrofit Kit
ASD LED Recessed Retrofit Kit was designed as an energy-efficient lighting solution for remodeling or new construction projects. It is an ideal replacement for an incandescent lamp in the industry s most
More informationCeiling Fan Installation Instructions
Owner s Manual Ceiling Fan Installation Instructions For 5AHR60XXD-L Series Fans READ AND SAVE THESE INSTRUCTIONS Total fan weight with light kit included 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14.
More informationSAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS EMERGENCY FLUORESCENT BATTERY PACK MODEL PS300, PS600, PS1400
INSTALLATION INSTRUCTIONS EMERGENCY FLUORESCENT BATTERY PACK MODEL PS300, PS600, PS1400 CAUTION: For safety and proper operation, read and follow instructions carefully before installation. FIELD INSTALLABLE
More informationInstallation guide. Philips EvoKit LED 2x4 and 2x2
Installation guide Philips EvoKit LED 2x4 and 2x2 This installation guide is only valid for the following Philips EvoKit models: Products 2x4 EvoKit 2x4 P 36L 36W 835 2 0-0 7 G2 EvoKit 2x4 P 36L 36W 840
More informationPARTS & ACCESSORIES INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:60010BZGTGLD SAFETY PRECAUTION. Canopy. Downrod. Housing. Transmitter CR2032/3V
L I G H T I N G INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:000BZGTGLD SAFETY PRECAUTION PARTS & ACCESSORIES Canopy Downrod Housing WARNING To make sure power is off before attempting installation. WARNING
More informationinstallation and operation manual for Hunter Ceiling Fans
For Your Records and Warranty Assistance Model Name: Catalog/Model No.: Serial No.: Date Purchased: Where Purchased: For reference also attach your receipt or a copy of your receipt to the manual. installation
More informationTSLED STAIRWELL INSTALLATION INSTRUCTIONS
TSLED STAIRWELL INSTALLATI INSTRUCTIS TSLED- 2FT TSLED - 4FT IMPORTANT READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIS FOR FUTURE REFERENCE. Fixtures must be wired in accordance with
More informationHalf Inch Round LED Rope Light
11235 West Bernardo Court, Suite 102 San Diego, CA 92127 888-880-1880 Fax: 707-281-0567 EnvironmentalLights.com Half Inch Round LED Rope Light LED Rope light is a beautiful and versatile way to light any
More informationJBS-100-EC Electronic controller replacement kit for JBS-100-ECP-A and JBS-100-ECW-A Installation Instructions
JBS-100-EC Electronic controller replacement kit for JBS-100-ECP-A and JBS-100-ECW-A Installation Instructions Description The Raychem JBS-100-EC is a replacement kit that can be used to replace the electronic
More informationInnovative Lighting R-Series Vertical Refrigeration
Installation Guide Innovative Lighting R-Series Vertical Refrigeration Door LED Conversionn Kits For Commercial Refrigerators and Freezers BEFORE YOU BEGIN INSTALLATION Read these instructions carefully.
More information3MAVR60XXD Series Fan. Owner s Guide and Installation Manual. CUL Model NO. : 3MAVR60XXD
Owner s Guide and Installation Manual 3MAVR60XXD Series Fan CUL Model NO. : 3MAVR60XXD Attach sales receipt to this card and retain as your proof of purchase DATE OF PURCHASE: MODEL NUMBER: RETAILER NAME:
More informationInnovative Lighting R-Series Horizontal Case Canopy LED Conversion Kits
Installation Guide Innovative Lighting R-Series Horizontal Case Canopy LED Conversion Kits For Commercial Refrigerated Multi-Deck Display Cases BEFORE YOU BEGIN INSTALLATION Read these instructions carefully.
More informationIntensity Level. Intensity Control. Mounting Plate. Signal Type Switch Signal Ports USB DC Power Port
Dimmer User Manual OVERVIEW This product can dim up to 50 fixtures over 200 feet of signal wire via a 0-10V or PWM signal for uniform control of light intensity delivered to crops. Extending the signal
More information72 ONYX XL FLAT PANEL ELECTRIC FIREPLACE
72 ONYX XL FLAT PANEL ELECTRIC FIREPLACE Model Numbers: 80005 OWNER S MANUAL WARNING Read and understand this entire owner s manual, including all safety information, before plugging in or using this product.
More informationOperation Manual Model: Light Switch Combo Universal Dimmer Module Item No.: WMR-252. Specification. Wiring
Operation Manual Model: Light Switch Combo Universal Dimmer Module Item No.: WMR-252 Featuring an unique universal wireless dimmer module receiver that allows remote controlling existing house hold dimmable
More informationOperating Instructions
Important information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect
More information3SKYR56XXD Series Fan. Owner s Guide and Installation Manual. ETL Model NO. : 3SKYR56(XXXXX)
Owner s Guide and Installation Manual 3SKYR56XXD Series Fan ETL Model NO. : 3SKYR56(XXXXX) Attach sales receipt to this card and retain as your proof of purchase DATE OF PURCHASE: MODEL NUMBER: RETAILER
More informationIMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit
Emergency Light Unit IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. Do not
More information3AVOR56XXD Series Fan. Owner s Guide and Installation Manual. ETL Model NO. : 3AVOR56XXXXX
Owner s Guide and Installation Manual 3AVOR56XXD Series Fan ETL Model NO. : 3AVOR56XXXXX Attach sales receipt to this card and retain as your proof of purchase DATE OF PURCHASE: MODEL NUMBER: RETAILER
More informationInnovative Lighting Smooth Light Recessed Luminaires
Installation Guide Innovative Lighting Smooth Light LED Recessed Luminaires BEFORE YOU BEGIN INSTALLATION Read these instructions carefully. Failure to follow these instructions will invalidate the warranty
More informationCEILING FAN OWNER'S MANUAL
Style that revolves around you. CEILING FAN OWNER'S MANUAL QUATRO 10/09 WARNING: Read and follow these instructions carefully and be mindful of all warnings shown throughout. GENERAL INSTALLATION & OPERATION
More informationTHINLINE TL2 SERIES INSTALLATION AND OPERATING INSTRUCTIONS
THINLINE 2.0 - TL2 SERIES DIE CAST ALUMINUM LED EXIT SIGNS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed
More informationCEILING FAN OWNER S MANUAL
CEILING FAN OWNER S MANUAL 5/03 I/O THE INDOOR/OUTDOOR FAN WARNING: Read and follow these instructions carefully and be mindful of all warnings shown throughout. GENERAL INSTALLATION & OPERATION INSTRUCTIONS
More informationLED CEILING LIGHT WITH MOTION SENSOR AND REMOTE. ITM. / ART Model: LM56123 CARE & USE INSTRUCTIONS
LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE ITM. / ART. 1165831 Model: LM56123 CARE & USE INSTRUCTIONS IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY For assistance with assembly or installation,
More informationCEILING FAN OWNER'S MANUAL
Style that revolves around you. CEILING FAN OWNER'S MANUAL VANTAGE with DC motor 12/14 WARNING: Read and follow these instructions carefully and be mindful of all warnings shown throughout. GENERAL INSTALLATION
More informationInstall the Fixture using a Stake (Pathway Models Only) Prepare the Fixture. Pathway and Bollards INSTALLATION OPTIONS: Installation Instructions for
Installation Instructions for Pathway and Bollards 920OA_OB. OUTDOOR GENERAL PRODUCT I NFORMATION: This product is suitable for wet locations. Pathway models are 2VAC input only. Refer to product specsheet
More informationELECTRIC FLAT PANEL FIREPLACE HEATER
ELECTRIC FLAT PANEL FIREPLACE HEATER Model Numbers: 80-2000A-42 OWNER S MANUAL AC 120V 60Hz 1500W WARNING Read and understand this entire owner s manual, including all safety information, before plugging
More informationMaxLite LED Vapor Tight Linear Fixture
General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions
More informationZ-800II / Z-1000II / Z-1020 Fog Machine User Manual
Z-800II / Z-1000II / Z-1020 Fog Machine User Manual English Français Deutsch 中文 2014 Antari Lighting and Effects Ltd. 1 User Manual Z-800II & 1000II & Z-1020 Fog Machine Congratulations on the purchase
More informationINSTALLATION AND OPERATING INSTRUCTIONS. For Reliance Controls Emergency Power Transfer Switch Kit Model Number 30216BRK
INSTALLATION AND OPERATING INSTRUCTIONS For Reliance Controls Emergency Power Transfer Switch Kit Model Number 30216BRK Congratulations on your purchase of the Reliance Controls Generator Power Transfer
More informationIntegrated Ventilation System
Integrated Ventilation System For use with models: IVS1, IVSR1, IVS2, IVSR2 Installation Instructions Part No. 65278 Rev. K Table of Contents Important Safety Instructions... 1 Important Information About
More informationSECTION (16140) - WIRING DEVICES
SECTION 26 27 26 (16140) - WIRING DEVICES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Receptacles, Connectors, Switches, and Finish Plates. B. Related Sections: 1. Section 00 31 13.43 (00370) -
More informationMILLA ELECTRIC FIREPLACE
MILLA ELECTRIC FIREPLACE MODEL NO. 064-3177-0 ASSEMBLY INSTRUCTIONS Toll-free: 1-888-670-6684 IMPORTANT: Please read this manual carefully before beginning assembly of this product. Keep this manual for
More informationIMPORTANT INSTRUCTIONS - OPERATING MANUAL
IMPORTANT INSTRUCTIONS - OPERATING MANUAL Models: AK80LSL, AK100LSL Exhaust Fan READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.
More informationINSTALLATION INSTRUCTION for ceiling fan
INSTALLATION INSTRUCTION for ceiling fan F8203 Installation & Operating Instructions for the Parrotuncle Owner s Installation,Manual Motor is core parts of the fan and the most expensive in all the components.
More informationCEILING FAN OWNER'S MANUAL
Style that revolves around you. CEILING FAN OWNER'S MANUAL GRANDER (GN) with DC motor 03/14 WARNING: Read and follow these instructions carefully and be mindful of all warnings shown throughout. GENERAL
More information14PRR62XXD Series Fan. Owner s Guide and Installation Manual. ETL Model NO. : 14PRR62(X)
Owner s Guide and Installation Manual 14PRR62XXD Series Fan ETL Model NO. : 14PRR62(X) Attach sales receipt to this card and retain as your proof of purchase DATE OF PURCHASE: MODEL NUMBER: RETAILER NAME:
More information