WHO IS RATH COMMUNICATIONS?

Size: px
Start display at page:

Download "WHO IS RATH COMMUNICATIONS?"

Transcription

1 NURSE CALL Tone & Visual Nurse Call Systems AREA OF REFUGE Area of Refuge & Elevator Landing Two-Way Communication Systems SECURITY Blue Light & Industrial Phones ELEVATOR PHONES POOL PHONES MADE IN THE USA N56W24720 N. Corporate Circle Sussex, WI Ver. 2 02/18

2 Area of Refuge/Elevator Landing Two-Way Communication Systems Nurse Call Systems Pool Phones Blue Light & Industrial Phones Elevator Phones WHO IS RATH COMMUNICATIONS? We have been in the Emergency Communication business for over 35 years and are the largest Communication System Manufacturer in North America. We are a privately owned company located in Sussex, WI. With over 600,000 phones in the field, you can rest assured that the quality and performance of our Communication Systems lead the industry. Our commitment to your success will be found in the quality of our products and the professionalism of our staff from the first inquiry to years after installation. NEW! TABLE OF CONTENTS Nurse Call Systems Area of Refuge Systems Blue Light Phones Elevator Phones Pool Phones Continuing Education Page 3-6 Page 7-12 Page Page Page 18 Page 19

3 NURSE CALL RATH Communications has developed two Nurse Call Systems to fit into the current healthcare market. The SmartCare Nurse Call Sysytem is a state-of-the-art tone and visual system with many features for the long-term care environment. The CliniCare Nurse Call System is a small and simple tone and visual system designed for small clinics and medical offices. Both are UL listed and supervised for functionality. CODE REQUIREMENTS UL 1069 Edition 7 The fundamental operation of a nurse call system shall include essential/required operation whose primary function is to provide notification and/or reset/cancellation of a staff-initiated or patient-initiated call signal to alert the staff. 1) Call annunciation at a nurse s station (audible and visual) 2) Call annunciation at the dome light (visual) 3) Call placed indicator on the patient station (visual) 4) Zone annunciation (audible and visual) 5) Call reset/cancellation SYSTEM The SmartCare System uses proprietary SmartLoop TM Power Technology so every Smart Device can be wired in sequence using standard CAT5 or better cable. The RJ45 connections make connecting devices a click away. Wireless E-Call Systems available. Contact us for a quote!

4 NURSE CONSOLES NURSE CALL 28 ZONE NURSE CONSOLE AP 56 ZONE NURSE CONSOLE AP CORRIDOR LIGHTS 112 ZONE NURSE CONSOLE AP SMART DOME LIGHT SDL SERIES TWO GANG SMART ZONE LIGHT SZL SERIES THREE GANG CALLING STATIONS CHECK-IN STATION CI SERIES SINGLE GANG PULL STRING STATION PS SERIES SINGLE GANG (WATER RESISTANT OPTION AVAILABLE) CODE BLUE STATION CB SERIES SINGLE GANG SINGLE BEDSIDE STATION BS SERIES SINGLE GANG DUAL BEDSIDE STATION DBS SERIES TWO GANG PANIC STATION PB SERIES SINGLE GANG DUTY/STAFF STATIONS CALL CORD 2900-CC6 DUTY STATION DS SERIES THREE GANG STAFF STATION SS SERIES FOUR GANG

5 NURSE CALL SYSTEM FEATURES CHECK-IN FEATURE: The RATH Check-In Feature is great for any long-term care facility. This solution uses software to monitor residents cognitive ability and health. When the system is installed there is a check-in window programmed into the software. Each active Check-In Device is recognized on the system and must check-in within that window or an alert will be sent to the staff. DATA LOGGING FEATURE: All calls that come into the system are logged in the software and saved including the call, call cancellation, date, and time. This data is important for managing staff and residents. The data can be exported for easy evaluation. SYSTEM CONTROLLERS: The brains of the SmartCare System are located in the Host Controller. Every system requires a programmed Host Controller. Programming is done through an Ethernet port and saved on a removable USB flash drive for programming backup. Systems that exceed the device maximum and/or distances require an Expansion Board. Both the Host Controller and Expansion Board should be on a UPS for surge protection and battery backup. HOST CONTROLLER 2900-HC EXPANSION BOARD 2900-EB POWER & BATTERY BACKUP: 24V POWER SUPPLY UPS UPS WITH BATTERY BACKUP 2900-PWRS2 RP RP BR PAGING SYSTEM: Every SmartCare System is capable of integrating with our Pocket Paging System. The connection for paging is done through an RS232 port on the Host Controller. The 5 watt Paging Transmitter is designed to cover even the largest facilities. When a high priority level call is placed and/or cancelled, a page will go out to every Pocket Pager on the system. This feature allows for staff to be mobile while still receiving notifications. A reminder feature sends a page when a call has gone over 5 minutes in duration. A page is also sent when a call is cancelled PP PPS

6 NURSE CALL SYSTEM The CliniCare System uses standard CAT5 or better cable and connects using RJ45 connectors. Each device on the system is wired back to the 6 Zone Annunciator Panel. The system is pre-programmed so it is simply plug and play right out of the box. ANNUNCIATOR CORRIDOR LIGHT 6 ZONE ANNUNCIATOR AP DOME LIGHT DL SERIES TWO GANG CALLING STATIONS PULL STRING STATION PS SERIES SINGLE GANG (WATER RESISTANT OPTION AVAILABLE) CODE BLUE STATION CB SERIES SINGLE GANG PANIC STATION PB SERIES SINGLE GANG SINGLE BEDSIDE STATION BS SERIES SINGLE GANG DUAL BEDSIDE STATION DBS SERIES TWO GANG 24V POWER SUPPLY UPS CALL CORD 2900-CC PWRS2 RP

7 AREA OF REFUGE CALL BOXES 1-10 SYSTEMS SR SRM MUSHROOM BUTTON RR POWDER COATED METAL LR EXTERIOR NEMA 4 FIBERGLASS SSRC2 WITH COVER LRC1 EXTERIOR NEMA 4 FIBERGLASS WITH COVER SSRC2 BRUSHED STAINLESS STEEL WITH COVER NSR BRUSHED NMBR BRUSHED ANTIQUE BRONZE BASE STATIONS POWER SUPPLY: 2500-PWR D/ PSS 5 ZONE SURFACE/ B 5 ZONE CABINET WITH DOOR FM 5 ZONE CABINET WITH DOOR D/ PSS 10 ZONE SURFACE/ B 10 ZONE CABINET WITH DOOR FM 10 ZONE CABINET WITH DOOR

8 AREA OF REFUGE 1-92 SYSTEMS CALL BOXES SP SPM MUSHROOM BUTTON RP POWDER COATED METAL LP EXTERIOR NEMA 4 FIBERGLASS SSPC2 WITH COVER LPC1 EXTERIOR NEMA 4 FIBERGLASS WITH COVER SSPC2 BRUSHED STAINLESS STEEL WITH COVER NSP BRUSHED NMP BRUSHED ANTIQUE BRONZE COMMAND CENTERS PART # RC(F) NC RC(F) NC RC(F) NC RC(F) NC RC(F) NC RC(F) NC RC(F) NC DESCRIPTION 12 ZONE-, (F) 12 ZONE- DESK MOUNT 16 ZONE-, (F) 16 ZONE- DESK MOUNT 28 ZONE-, (F) 28 ZONE- DESK MOUNT 36 ZONE-, (F) 36 ZONE- DESK MOUNT 56 ZONE-, (F) 56 ZONE- DESK MOUNT 76 ZONE-, (F) 76 ZONE- DESK MOUNT 92 ZONE-, (F) 92 ZONE- DESK MOUNT SURFACE/ DISTRIBUTION MODULE DESK MOUNT POWER SUPPLY: RP OR RP NOTE: DISTRIBUTION MODULE IS INCLUDED WITH BASE STATION.

9 AREA OF REFUGE CALL BOXES IP SYSTEMS SIP RIP EXTERIOR NEMA 4 FIBERGLASS SIPC2 WITH COVER SIPC2 BRUSHED STAINLESS STEEL WITH COVER NSIP BRUSHED NMBIP BRUSHED ANTIQUE BRONZE COMMAND CENTERS PART # DESCRIPTION R_V 10 ZONE- FLUSH (CF) OR SURFACE (C) MOUNT CABINET NCV 10 ZONE- DESK MOUNT R_V 16 ZONE- FLUSH (CF) OR SURFACE (C) MOUNT CABINET NCV 16 ZONE- DESK MOUNT R_V 32 ZONE- FLUSH (CF) OR SURFACE (C) MOUNT CABINET NCV 32 ZONE- DESK MOUNT R_V 48 ZONE- FLUSH (CF) OR SURFACE (C) MOUNT CABINET NCV 48 ZONE- DESK MOUNT R_V 64 ZONE- FLUSH (CF) OR SURFACE (C) MOUNT CABINET NCV 64 ZONE- DESK MOUNT R_V 80 ZONE- FLUSH (CF) OR SURFACE (C) MOUNT CABINET NCV 80 ZONE- DESK MOUNT R_V 96 ZONE- FLUSH (CF) OR SURFACE (C) MOUNT CABINET NCV 96 ZONE - DESK MOUNT R_V 112 ZONE- FLUSH (CF) OR SURFACE (C) MOUNT CABINET NCV 112 ZONE- DESK MOUNT R_V 128 ZONE- FLUSH (CF) OR SURFACE (C) MOUNT CABINET NCV 128 ZONE- DESK MOUNT NOTE: DISTRIBUTION MODULE IS INCLUDED WITH BASE STATION VOIP DESK MOUNT DISTRIBUTION MODULE SURFACE/ POWER SUPPLY: RP

10 AREA OF REFUGE ELEVATOR LANDING SIGNAGE H X 6 W 7041E 8 X 8 PHOTO LUMINESCENT X E/7050ED 14 LED LIGHT UP WITH BATTERY BACKUP 120/277V AREA OF REFUGE X 8 PHOTO LUMINESCENT X 8 PHOTO LUMINESCENT X X R 5 X L 5 X /7050D 14 LED LIGHT UP WITH BATTERY BACKUP 120/277V DIAMETER AREA OF RESCUE ASSISTANCE ALL SIGNS AVAILABLE WITH THE ACTIVE WHEELCHAIR ICON X 8 PHOTO LUMINESCENT X X /7090D 14 LED LIGHT UP WITH BATTERY BACKUP 120/277V

11 AREA OF REFUGE COMMUNICATION SUPERVISION 1-10 ANALOG SYSTEMS Each 2100 Series Call Box comes with built-in communication verification software and failure relay output which can be connected to an addressable fire alarm module or the fire control panel ANALOG SYSTEMS SPRVSR Monitors remote Call Boxes, Base Station phone, and telephone lines Provides a relay output when it does not detect a component of the system Wall mounted swing out bracket Connections: RJ11 connections to each Call Box, Base Station phone, phone line, and punch down terminal connections to Distribution Module Power: 12vdc (includes UL listed transformer that plugs into a 120vac backed up source, or use RATH model RP or RP )

12 AREA OF REFUGE 2500-VOIPM IP SYSTEMS Power: 120vac from a backed up power source or RATH RP Current draw: 270mA Output: (2) Form 1C SPDT switches, (1) NO and (1) NC Rated 277vac at 20A Ethernet: (2) 10 Base-T or 100 Base-T, 8-pin RJ45 connection Network: Ethernet IPv4 Requires static IP addresses for all components Supports web browser: HTTP/HTTPS, XML, Modbus/TCP & SNMP protocols LED indicators: green (power on), yellow (network) Temperature range: -40F +150F Non-volatile memory Electromagnetic compliance: IEC CISPR 22, 24 FCC 47CFR15 (Class B) UL Wall mount enclosure with door POWER SUPERVISION 2500-UPSMONITOR Comes with Power Failure Relay Output Power Supervision requires additional purchase of: UPS Backup RP or RP HOUR FIRE-RATED CABLE PART # DESCRIPTION CABLE RP M CI 2 HOUR FIRE-RATED 2 PAIR COMM CABLE (100 METER) RP M CI 2 HOUR FIRE-RATED 2 PAIR COMM CABLE (300 METER) RP UL LISTED CI 2 HOUR FIRE-RATED SINGLE PAIR COMM CABLE (500 FEET) RP UL LISTED CI 2 HOUR FIRE-RATED SINGLE PAIR COMM CABLE (1,000 FEET) RP M4 CI 2 HOUR FIRE-RATED 4 PAIR COMM CABLE (100 METER) (IP SYSTEMS ONLY) RP M4 CI 2 HOUR FIRE-RATED 4 PAIR COMM CABLE (300 METER) (IP SYSTEMS ONLY) COMMUNICATION & POWER CABLE PART # DESCRIPTION RP AWG SHIELDED 2 PAIR COMM CABLE (1,000 FEET) RP P 18-2 SOLID SHIELDED POWER CABLE (1,000 FEET) (1-10 ANALOG SYSTEMS ONLY)

13 BLUE LIGHT PHONES 9 WIRED TOWERS (2100-TP SERIES) STANDARD FEATURES: Calls up to 5 phone numbers Blue beacon/strobe with photocell Recessed illuminated face plate Call assurance LED Blue strobe 11 gauge steel ADA compliant OPTIONAL FEATURES: Dome Camera Discrete View TM Camera Siren Mass Notification Speaker Housing Custom colors and lettering Amber or red strobe Wide Area Light Dual button face plate Face plate cover COLOR OPTIONS: WHITE (STANDARD) RED LETTER POSTAL BLUE SAFETY YELLOW ARCHITECTURAL BRONZE EQUIPMENT BLUE CAMPUS GREEN WHITE WITH BLUE TEXT (STANDARD) 9 SOLAR TOWERS (2100-TS SERIES) HEIGHT WITH SOLAR PANEL: 12 STANDARD FEATURES: Calls up to 5 phone numbers Blue beacon/strobe with photocell Recessed illuminated face plate Call assurance LED Blue strobe 11 gauge steel ADA compliant OPTIONAL FEATURES: Dome Camera Discrete View TM Camera Siren Custom colors and lettering Amber or red strobe Service indicator Dual button face plate Face plate cover COLOR OPTIONS: WHITE (STANDARD) RED LETTER POSTAL BLUE SAFETY YELLOW ARCHITECTURAL BRONZE EQUIPMENT BLUE CAMPUS GREEN WHITE WITH BLUE TEXT (STANDARD) 5 8 PEDESTALS (2100-PP SERIES) STANDARD FEATURES: Calls up to 5 phone numbers Blue beacon/strobe Recessed illuminated face plate Call assurance LED Blue strobe 11 gauge steel ADA compliant OPTIONAL FEATURES: Discrete View TM Camera Custom colors and lettering Amber or red strobe Dual button face plate Face plate cover COLOR OPTIONS: WHITE (STANDARD) RED LETTER POSTAL BLUE SAFETY YELLOW ARCHITECTURAL BRONZE EQUIPMENT BLUE CAMPUS GREEN WHITE WITH BLUE TEXT (STANDARD)

14 36 WIRED CALL STATIONS (2100-CP SERIES) BLUE LIGHT PHONES STANDARD FEATURES: Calls up to 5 phone numbers Recessed illuminated face plate Call assurance LED Blue strobe Aluminum enclosure ADA compliant OPTIONAL FEATURES: COLOR OPTIONS: Discrete View TM Camera WHITE (STANDARD) Siren RED LETTER Mass Notification Speaker Housing POSTAL BLUE Custom colors and lettering SAFETY YELLOW Stainless Steel enclosure Amber or red strobe EQUIPMENT BLUE Pole mount bracket CAMPUS GREEN Dual button face plate Face plate cover ARCHITECTURAL BRONZE WHITE WITH BLUE TEXT (STANDARD) 36 SOLAR CALL STATIONS (2100-CS SERIES) STANDARD FEATURES: Calls up to 5 phone numbers Recessed illuminated face plate Call assurance LED Blue strobe Aluminum enclosure ADA compliant OPTIONAL FEATURES: Discrete View TM Camera Siren Mass Notification speaker housing Custom colors and lettering Stainless Steel enclosure Amber or red strobe Pole mount bracket Dual button face plate Face plate cover COLOR OPTIONS: WHITE (STANDARD) RED LETTER POSTAL BLUE SAFETY YELLOW ARCHITECTURAL BRONZE EQUIPMENT BLUE CAMPUS GREEN WHITE WITH BLUE TEXT (STANDARD) 30 ECO LIGHT WEIGHT CALL STATIONS (2100-E SERIES) STANDARD FEATURES: Calls up to 5 phone numbers Call assurance LED Blue strobe Aluminum enclosure ADA compliant OPTIONAL FEATURES: Custom colors and lettering Stainless Steel enclosure Amber or red strobe Pole mount bracket Dual button face plate Face plate cover COLOR OPTIONS: WHITE (STANDARD) RED LETTER EQUIPMENT BLUE WHITE WITH BLUE TEXT (STANDARD)

15 BLUE LIGHT PHONES POWER OPTIONS 120VAC OR 12VDC SOLAR DUSK2DAWN (SEE BELOW) COMMUNICATION OPTIONS Ask About our 4G Solution! LANDLINE CELLULAR 2-WAY RADIO VOIP WI-FI VOIP 900MHZ DUSK2DAWN TECHNOLOGY RATH Dusk2Dawn Technology feature allows for the utilization of intermittent power that is controlled by a timer or photocell. The technology can run on battery power while the AC power is absent and recharge when power is available.

16 SMARTPHONES BEHIND THE PANEL (CONTACT US FOR DIRECT MOUNT COMPETITOR PLATES) ELEVATOR PHONES CC RA RA SS RS POWDER COATED METAL LF NEMA 4 FIBERGLASS EXTERIOR BL HEAVY DUTY ABS SSC2 (WITH COVER) NSS BRUSHED ACCESSORIES DO BRUSHED SS BRUSHED MB BRUSHED ANTIQUE BRONZE NMB BRUSHED ANTIQUE BRONZE SSC2 BRUSHED (WITH COVER) IP INTERFACES ELEVATOR PHONE INTERCOMS (LOBBY & MACHINE ROOM UNITS) 2100-VOIP CELLULAR INTERFACES 2100-VOIPLC UPS RP GSM UNIT 2100-GSMLC CDMA UNIT 2100-CDMALC

17 ELEVATOR PHONES LINE POWERED PHONES BEHIND THE PANEL (CONTACT US FOR DIRECT MOUNT COMPETITOR PLATES) RAS CC RA SS RS POWDER COATED METAL LF NEMA 4 FIBERGLASS EXTERIOR RD HEAVY DUTY ABS SSC2 WITH COVER NSS BRUSHED STAINLESS STEEL DO BRUSHED STAINLESS STEEL SS BRUSHED STAINLESS STEEL MB BRUSHED ANTIQUE BRONZE NMB BRUSHED ANTIQUE BRONZE SSC2 BRUSHED WITH COVER

18 POOL PHONES 610POOL_ INTERIOR HANDSET 646POOL_ INTERIOR HANDSET 674POOL_ INTERIOR HANDSET 675POOL_ INTERIOR HANDSET (MANUAL DIAL) 624POOL_ HANDSET WITH ENCLOSURE 624MPOOL_ HANDSET WITH ENCLOSURE (MANUAL DIAL) 970POOL_ SPEAKERPHONE WITH ENCLOSURE DA_ SPEAKERPHONE WIFIV SPEAKERPHONE 690RDPOOL_ HANDSET WITH ENCLOSURE 990RDPOOL_ SPEAKERPHONE WITH ENCLOSURE 690SYPOOL_ HANDSET WITH ENCLOSURE 990SYPOOL_ SPEAKERPHONE WITH ENCLOSURE 624POOLVOIP_ HANDSET WITH ENCLOSURE 624MPOOLVOIP_ HANDSET WITH ENCLOSURE (MANUAL DIAL) 970VOIP_ SPEAKERPHONE WITH ENCLOSURE 984POOL_ SPEAKERPHONE 984POOLC1_ SPEAKERPHONE WITH COVER

19 CONTINUING EDUCATION LUNCH & LEARN AIA CERTIFIED LUNCH & LEARNS RATH Lunch & Learn programs are 50 minute presentations with an additional 10 minutes of questions and discussion. THE COURSES COVER: Scope and Design Communication and Signage Requirements IBC, NFPA, and ADA Code Requirements Location: Course can be completed at your office or via webinar as part of our distance learning program Lunch: Free catered lunch provided for all attendees Continuing Education Units: 1 AIA CEU in HSW TECHNICAL TRAINING WEBINARS How to properly wire, set-up, and install RATH SmartRescue and Command Center Communication Systems. Available options and best practices for specifying, installing, and implementing RATH IP Communication Systems. We will ship a kit to you and schedule a one-on-one webinar or Q&A session. Upon completion, ship the kit back at our expense.

20 THE CODE EXPERTS INTERNATIONAL BUILDING CODE (IBC) IBC 2009 & Two-Way Communication. A two-way communication system complying with Sections and shall be provided at the landing serving each elevator or bank of elevators on each accessible floor that is one or more stories above or below the level of exit discharge. Exceptions: 1. Two-way communication systems are not required at the landing serving each elevator or bank of elevators where the two-way communication system is provided within Areas of Refuge in accordance with Section Directions. Directions (Part #7049) for the use of the two-way communication system, instructions for summoning assistance via the two-way communication system and written identification of the location shall be posted adjacent to the two-way communication system. Signage shall comply with the ICC A requirements for visual characters Signage. Signage indicating special accessibility provisions shall be provided as shown: Each door providing access to an Area of Refuge an adjacent floor area shall be identified by a sign stating: AREA OF REFUGE. (Part #7043/7044) Each door providing access to an exterior area for assisted rescue shall be identified by a sign stating: EXTERIOR AREA FOR ASSISTED RESCUE. (Part #7086) Where exit sign illumination is required by Section , the signs shall be illuminated. (Part #7050) Additionally, visual characters, raised character and braille signage complying with ICC A shall be located at each door to an Area of Refuge and exterior Area for Assisted Rescue in accordance with Section (Part #7043/7044) Signage shall comply with the ICC A requirements for visual characters and include the International Symbol of Accessibility. IBC 2015 & 2018 codes can be found in the Code Requirements section of our website. AMERICANS WITH DISABILITIES ACT (ADA) REQUIRED MOUNTING HEIGHTS: NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) NFPA SUPERVISION REQUIREMENTS: All pathways between a remote area of refuge station and the central control point shall be monitored for integrity Power Supplies- All control units shall meet the power supply requirements of section 10.6s Monitoring Integrity of Power Supplies Unless otherwise permitted or required by and all primary and secondary power supplies shall be monitored for the presence of voltage at the point of connection to the system Failure of either the primary or secondary power supply shall result in a trouble signal in accordance with section The secondary power supply (battery backup) shall have sufficient capacity to operate the system under quiescent load (system operating in a non-alarm condition) for a minimum of 24 hours and, at the end of that period, shall be capable of operating all alarm notification appliances used for evacuation or to direct aid to the location of an emergency for 5 minutes. CABLE REQUIREMENTS: Area of Refuge emergency communications systems shall have a pathway survivability of Level 2 or Level 3. (Level 1 is permitted if where the building is less than 2-hour fire-rated construction) Pathway Survivability Level 2- Shall consist of one or more of the following: (1) 2-hour fire-rated circuit integrity (CI) or fire-resistive cable. (2) 2-hour fire-rated cable system (electrical circuit protective systems). (3) 2-hour fire-rated enclosure or protected area. (4) Performance alternatives approved by the authority having jurisdiction Pathway Survivability Level 3- Shall consist of pathways in buildings that are fully protected by an automatic sprinkler system in accordance with NFPA13 and one or more of the following: (1) 2-hour fire-rated circuit integrity (CI) or fire-resistive cable. (2) 2-hour fire-rated cable system (electrical circuit protective systems). (3) 2-hour fire-rated enclosure or protected area. (4) Performance alternatives approved by the authority having jurisdiction.

800-451-1460 www.area-of-refuge.com BASE STATIONS CALL BOXES SIGNAGE Area of Refuge/Elevator Landing Two-Way Communication Systems www.area-of-refuge.com Nurse Call Systems www.rathnursecall.com Pool Phones

More information

NURSE CALL. Tone & Visual Nurse Call Systems. Area of Refuge & Elevator Landing Two-Way Communication Systems POOL PHONES

NURSE CALL. Tone & Visual Nurse Call Systems. Area of Refuge & Elevator Landing Two-Way Communication Systems POOL PHONES NURSE CALL Tone & Visual Nurse Call Systems AREA OF REFUGE Area of Refuge & Elevator Landing Two-Way Communication Systems PUBLIC SAFETY Blue Light & Industrial Phones ELEVATOR PHONES POOL PHONES Ver.

More information

SECTION NURSE CALL SYSTEM

SECTION NURSE CALL SYSTEM NURSE CALL SMARTCARE NURSE CALL SOLUTION Architectural Specifications Part 1 General SECTION 275223 - NURSE CALL SYSTEM 1.0 Summary 1.1 This section includes nurse call system and requirements for system

More information

Pre-Installation Requirements:

Pre-Installation Requirements: AlphaRefuge 2100 Series (V3) Area of Refuge and Rescue Assistance system Installation, Use and Wiring Instructions Pre-Installation Requirements: 120V Power Determine Communication: 1. Dedicated analog

More information

TrueCom. Building Communications Systems 5115-Series , Area of Rescue Communications System. Description

TrueCom. Building Communications Systems 5115-Series , Area of Rescue Communications System. Description TrueCom Building Communications Systems 5115-Series 5115-9001, -9002 Area of Rescue Communications System Description The Simplex 5115-9001 and -9002 Area of Rescue Communications System provides buildings

More information

Fire Alarm System Fundamentals

Fire Alarm System Fundamentals Fire Alarm System Fundamentals Mircom is the largest and oldest privately owned fire alarm and life safety manufacturer in North America and 5th largest overall with 50 years of industry experience. Mircom

More information

ERS-3600B. PERS-3600B Personal Emergency Reporting System

ERS-3600B. PERS-3600B Personal Emergency Reporting System PERS-3600B Personal Emergency Reporting System ERS-3600B A Complete Emergency System For Comprehensive Care The Linear PERS-3600B includes a built-in speakerphone and reminder message capability, providing

More information

The Standard In Safety

The Standard In Safety The Standard In Safety GAI-TRONICS A Hubbell Company GAI-Tronics, a Hubbell Company, has been a leading manufacturer in the emergency communications industry for over 65 years. Oil rigs, power plants,

More information

HOUSING DEVICES, INC.

HOUSING DEVICES, INC. Area of Refuge Communications Area of Refuge Signage VandalProof Building Intercoms Telephone Entry Systems (HDI) was established in 1978 to serve the entry security and emergency communications needs

More information

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2 Architectural & Engineering Specifications Control Panel 1.0 GENERAL... 2 1.1 SCOPE OF WORK... 2 1.1.1 Introduction... 2 1.2 GENERAL CONDITIONS... 2 1.2.1 After-Sales Support... 2 1.2.2 Quality assurance...

More information

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor A1UL PERS Personal Emergency Response System TABLE OF CONTENTS 1. READ THIS FIRST... 1 2. SYSTEM OVERVIEW.. 1 3. COMPONENTS 2 4. UNIT OPERATION! Standby Mode.. 3! Emergency Activation. 3! Answering Incoming

More information

Control/Communicator

Control/Communicator Architectural & Engineering Specifications Control/Communicator 1.0 GENERAL... 2 1.1 SCOPE OF WORK... 2 1.1.1 Introduction... 2 1.2 GENERAL CONDITIONS... 2 1.2.1 After-Sales Support... 2 1.2.2 Quality

More information

For Dealers / Integrators / Architects. IS Series. Video Intercom. Building Communication. Controlling Security.

For Dealers / Integrators / Architects. IS Series. Video Intercom. Building Communication. Controlling Security. For Dealers / Integrators / Architects IS Series Video Intercom Building Communication. Controlling Security. IS Series helps save money Control multiple functions from any location to help reduce overall

More information

OJD ITB No Attachment E Duress Alarm Equipment Specifications

OJD ITB No Attachment E Duress Alarm Equipment Specifications Duress Alarm Equipment Specifications PART 1 GENERAL 1.1 SECTION INCLUDES A. Duress devices. B. Alarm control panel. C. Signaling devices. 1.2 REFERENCE STANDARDS A. NFPA 70 - National Electrical Code;

More information

SP40S-D. Kingfisher Company, inc. Features: Description:

SP40S-D. Kingfisher Company, inc. Features: Description: Kingfisher Company, inc. SP40S-D Features: Multi-use applications The system can function as an evacuation system, an emergency messaging system, and an employee notification system Fire code applications

More information

Emergency Communications Tower Applications (Solar/Wireless/Surveillance)

Emergency Communications Tower Applications (Solar/Wireless/Surveillance) Emergency Communications Tower Applications (Solar/Wireless/Surveillance) Providing Communication Solutions for 70+ Years What is your scenario? - No Power or Telephone Line Available - No Power Available;

More information

The New Standard In Safety

The New Standard In Safety Sold by: http://www.twacomm.com Toll Free: (877) 389-0000 The New Standard In Safety GAI-TRONICS A Hubbell Company GAI-Tronics, a Hubbell Company, has been a leading manufacturer in the emergency communications

More information

Integrated Security Solutions

Integrated Security Solutions Integrated Security Solutions Table of Contents Control Panels 4 Keypads 8 Communication Modules 16 I/O Expanders 20 Door Control 24 Home Automation 25 RF Receivers 26 3 Our integrated security solutions

More information

Specification/ Data Sheet

Specification/ Data Sheet Specification/ Data Sheet TRITON RP Agent Release Control Panel FEATURES Agent Release Control Panel designed specifically for suppression release operation with: Four initiating device circuits (IDCs)

More information

EC-BOS-602/616 AX Security

EC-BOS-602/616 AX Security D a t a s h e e t EC-BOS-602/616 AX Security Comprehensive, easy-to-use Access Control management solution Overview The heart of EC-Net AX Security is the EC- BOS-602/616 AX Security, an advanced IP-based

More information

Tek-SAFE Area of Rescue Assistance System

Tek-SAFE Area of Rescue Assistance System Tek-SAFE Area of Rescue Assistance System Submittal Package as of 5/25/2017 Phone: 828.524.9967 Toll-Free: 800.327.8466 Sales: Option 2 Tech Support: Option 3 324 Industrial Park Road Franklin, NC 28734

More information

Installation & Operations Manual

Installation & Operations Manual Installation & Operations Manual Emergency Call Box 2100-986DA 2100-986DAI Made in the USA 2 Year Warranty N56W24720 N. Corporate Circle Sussex, WI 53089 800-451-1460 www.rathcommunications.com RP85000986DA

More information

PERS-3600 PERSONAL EMERGENCY REPORTING SYSTEM INSTALLATION & OPERATION INSTRUCTIONS

PERS-3600 PERSONAL EMERGENCY REPORTING SYSTEM INSTALLATION & OPERATION INSTRUCTIONS PERS-600 PERSONAL EMERGENCY REPORTING SYSTEM BY BY INSTALLATION & OPERATION INSTRUCTIONS (760) 8-7000 USA & Canada (800) -587 & (800) 9-0 Toll Free FAX (800) 68-0 www.linearcorp.com CONTENTS CONTROL AREA

More information

Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS. Feature Charts

Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS. Feature Charts Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS Feature Charts Control Panels FEATURE CHART LYNX Plus (L3000) (Supported Feature) (Not Supported) N/A (Not Applicable) LYNX Touch (L5210)

More information

GE Security Sound and Communications. Product Guide. Telligence. Voice-over-IP Patient-Staff Communication System. imagination at work

GE Security Sound and Communications. Product Guide. Telligence. Voice-over-IP Patient-Staff Communication System. imagination at work GE Security Sound and Communications Product Guide Telligence Voice-over-IP Patient-Staff Communication System imagination at work Telligen Voice-over-IP Patient-Staff Communication System Built to work

More information

Commercial and Light Industrial Fire Alarm Control Panel

Commercial and Light Industrial Fire Alarm Control Panel FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel Features Easily expandable. All new plug-in board design Two supervised audible circuits Lamp and system trouble circuit test Ground

More information

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160 All-In-One Wireless Security System V3.2 Programming Guide Model # MG6130 / MG6160 We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com

More information

POWER SOURCES MODEL NO. DESCRIPTION PRICE

POWER SOURCES MODEL NO. DESCRIPTION PRICE POWER SOURCES BE-961-1 BE-961-2 BE-961-5 BE-961-6 Battery Eliminator - 120VAC to 9VDC Includes 10 Flex Conduit and Transformer Powers up to 3 ECLs or 3 EBs Battery Eliminator - Same as above with Supervisory

More information

LORAIN CIP 4890/48120 DC Power System

LORAIN CIP 4890/48120 DC Power System DC Power for Business-Critical Continuity Key Features Compact flexibility provides rectifiers, distribution, and controller in one shelf Constant power delivers more current at lower voltages to meet

More information

DIVISION 26 ELECTRICAL SECTION FIRE ALARM SYSTEM

DIVISION 26 ELECTRICAL SECTION FIRE ALARM SYSTEM DIVISION 26 ELECTRICAL SECTION 26 81 11 PART 1 GENERAL 1.01 DESCRIPTION A. Furnish and install all equipment and accessories for a complete local, analog addressable, manually and automatically actuated,

More information

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel PROTECTOWIRE FireSystems Features Easily expandable Two supervised audible circuits Lamp and system trouble circuit test Ground fault detection Initiating device circuit (IDC) alarm test Monitors up to

More information

Communication Products

Communication Products Communication Products TELEPHONE ACCESS SYSTEMS MUS-1000SDK Mircom Electronic Directory Slim Line Lobby Panels Mircom s MUS-1000SDK Electronic Directory Slim Line Lobby Panels are designed to provide Resident/Visitor

More information

Nurse Call Systems & Emergency Call Systems. Overview of ANSI/UL 1069 and ANSI/UL 2560

Nurse Call Systems & Emergency Call Systems. Overview of ANSI/UL 1069 and ANSI/UL 2560 Nurse Call Systems & Emergency Call Systems Overview of ANSI/UL 1069 and ANSI/UL 2560 The Association of Electrical and Overview National Consensus Standards American National Standards Institute (ANSI)

More information

Autonomous control unit

Autonomous control unit Supersedes October 2016 Autonomous control unit Description Eaton s Autonomous Control Unit (), part of the ALERiTY integrated MNS platform, is a supervised in-building emergency communications system

More information

CM800 Emergency Call System

CM800 Emergency Call System Submittal Package as of 5/25/2017 Phone: 828.524.9967 Toll-Free: 800.327.8466 Sales: Option 2 Tech Support: Option 3 324 Industrial Park Road Franklin, NC 28734 tektone@tektone.net Fax: 828.524.9968 Copyright

More information

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. GENERAL DESCRIPTION... 2 2. STANDARD AND OPTIONAL PARTS LIST... 2 3. FEATURE DEFINITIONS... 3 4. TERMINAL DRAWING AND SPECIAL

More information

Monitoring Solutions

Monitoring Solutions GSM Systems Monitor: Temperature, Humidity, Power, Water, Smoke, Carbon Monoxide and More September 2016 Table of Contents GSM Systems... 3 Argon 100 GSM... 3 Ares 12 & 14 GSM... 4 Poseidon2 4002... 5

More information

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250BP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250BP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM SECURITY ACCESS AND SURVEILLANCE SECTION 13850 VISTA 250BP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM ADEMCO Group 165 Eileen Way Syosset, New York 11791 1-800-645-7568 SECTION 13850 DETECTION

More information

TALKAPHONE MASTER CATALOG

TALKAPHONE MASTER CATALOG W W W. TA L K A P H O N E. C O M 773.539.1100 TALKAPHONE MASTER CATALOG THE LEADERS IN SECURITY AND LIFE SAFETY COMMUNICATIONS TABLE OF CONTENTS About Talkaphone... 1-2 Housing Towers... 3-6 Wall Mounts...

More information

WAVE SEQUENCER DELIVERS:

WAVE SEQUENCER DELIVERS: The WAVE Sequencer employs state-of-the-art wireless technology to shut down and isolate vulnerable electrical components during local thunderstorms. The Sequencer receives digitally encoded signals from

More information

Integrated Security Solutions

Integrated Security Solutions Integrated Security Solutions Table of Contents Control Panels 4 Keypads 8 Communication Modules 16 I/O Expanders 20 Door Control 24 Home Automation 25 RF Receivers 26 2 Our integrated security solutions

More information

Situational Awareness for Life & Fire Safety. October 10, 2013

Situational Awareness for Life & Fire Safety. October 10, 2013 Situational Awareness for Life & Fire Safety October 10, 2013 New Fire Standards Control and Communication Units For Fire Alarm Control Units Mass notification products shall be constructed to comply with

More information

SAFEPATH Mass Notification System (SPMNS)

SAFEPATH Mass Notification System (SPMNS) Supersedes February 2016 SAFEPATH Mass Notification System (SPMNS) SP40S SPB-320 SPB-80/4 SPB-160 PS-8-LP SPMNS-MIC SP4Z-A/B Contents Page SPMNS.... 2-4 SPMNS-MIC...3 Expansion Options SAFEPATH 2-zone

More information

SAFEPATH SAFEPATH. Emergency communications system

SAFEPATH SAFEPATH. Emergency communications system SAFEPATH SAFEPATH Emergency communications system ALERiTY Integrated mass notification solutions by Eaton; designed to protect, alert and inform your most critical resources your people ALERiTY /a ler

More information

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide Product Overview The IntelliKnight 5820XL is an intelligent addressable fire alarm control panel designed for flexibility and reliability.

More information

SECTION INTRUSION DETECTION

SECTION INTRUSION DETECTION (NOTE TO DESIGNER: These Specifications are basic minimum criteria to be met in preparing the final specifications for this section, which is the responsibility of the Designer.) SECTION 28 16 00 INTRUSION

More information

Public Safety DAS Annunciator Panel

Public Safety DAS Annunciator Panel Public Safety DAS Annunciator Panel 120 VAC Models: 1221-A, 1221-B, 1221-C Revision D 91117 48 VDC Models: 1221-A-48, 1221-B-48, 1221-C-48 24 VDC Models: 1221A-24, 1221-B-24, 1221-C-24 CAUTION: (Read This

More information

SECTION COMMON WORK RESULTS FOR SAFETY AND SECURITY 1.1 RELATED SECTIONS

SECTION COMMON WORK RESULTS FOR SAFETY AND SECURITY 1.1 RELATED SECTIONS SECTION 280500 COMMON WORK RESULTS FOR SAFETY AND SECURITY PART 1 - GENERAL 1.1 RELATED SECTIONS A. All division 28 work shall, in addition to all division 1 specification sections, comply with all of

More information

SMART. FLEXIBLE. RELIABLE.

SMART. FLEXIBLE. RELIABLE. SMART. FLEXIBLE. RELIABLE. Life Safety Communications for Education, Healthcare, Correctional, and Industrial/Commercial Applications. WWW.CAREHAWK.COM THE CH1000(LT) PLATFORM The CH1000(LT), a life safety

More information

ELECTRONIC SOUNDER STROBE Model : AVD-C407

ELECTRONIC SOUNDER STROBE Model : AVD-C407 ELECTRONIC SOUNDER STROBE Model : AVD-C407 MULTRON range of combination Electronic Sounders with Strobe Lights are designed to complement our Fire Alarm products both technically and aesthetically as an

More information

Rugged Telephones GAI-TRONICS. A Hubbell Company

Rugged Telephones GAI-TRONICS. A Hubbell Company Rugged Telephones GAI-TRONICS A Hubbell Company GAI-Tronics, a Hubbell Company, has been the leading manufacturer in the rugged communications industry for over 65 years. Oil rigs, power plants, nuclear

More information

Fall Prevention. Systems. Discount Fall Monitoring Packages Available. Featuring. New! Economy Cordless Alarm see page 2

Fall Prevention. Systems. Discount Fall Monitoring Packages Available. Featuring. New! Economy Cordless Alarm see page 2 Discount Fall Monitoring Packages Available Fall Prevention Systems Featuring We take pride in our outstanding Customer Service. At Smart Caregiver Corporation, we strive to keep our customers feeling

More information

LORAIN CSP DC Power System

LORAIN CSP DC Power System DC Power for Business-Critical Continuity Key Features Compact flexibility provides more space for revenue generating equipment Constant power delivers more current at lower voltages to meet load or recharge

More information

Safer Smarter More Livable Buildings. TX3 Voice Entry & Access Control Solutions. [TX3] Series.

Safer Smarter More Livable Buildings. TX3 Voice Entry & Access Control Solutions. [TX3] Series. Safer Smarter More Livable Buildings TX3 Voice Entry & Access Control Solutions [TX3] Series www.mircom.com/tx3 ELECTRONIC DIRECTORY HANDS-FREE TX3-200-8U-B Surface Mount (Hooded) Universal Large 8 line

More information

Addressable Fire Alarm Control Panel

Addressable Fire Alarm Control Panel PRODUCT SPECIFICATION XR2400F Addressable FACP Addressable Fire Alarm Control Panel Description The DMP XR2400F Addressable Fire Alarm Control Panel is an expandable Fire Alarm Control with built-in DACT

More information

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250FBP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250FBP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM SECURITY ACCESS AND SURVEILLANCE SECTION 13850 VISTA 250FBP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM ADEMCO Group 165 Eileen Way Syosset, New York 11791 1-800-645-7568 SECTION 13850 DETECTION

More information

PROTECTION CABINETS SUPERVISION CABINETS FOR AUTOMATIC EXTERNAL DEFIBRILLATORS (AEDs)

PROTECTION CABINETS SUPERVISION CABINETS FOR AUTOMATIC EXTERNAL DEFIBRILLATORS (AEDs) PROTECTION CABINETS SUPERVISION CABINETS FOR AUTOMATIC EXTERNAL DEFIBRILLATORS (AEDs) FEATURES OF AIVIA PROTECTION MODELS H : 423 mm The Aivia range has been designed and manufactured by the French company

More information

TrueAlarm Fire Alarm Systems

TrueAlarm Fire Alarm Systems OPERATOR OPERATOR OR TROUBLE CONDITION: TO : FIRE PRIORITY 2SYSTEM SYSTEM SIGNALS POWER INDICATOR. SUPERVISORYTROUBLE SILENCED ON D. TO SILENCE SIGNALS: - PRESS " SILENCE". SUPV TBL SYSTEM ACK ACK ACK

More information

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once. Table of Content 1.1General Description----------------------------------------------------------------------2 2.2System Setup-----------------------------------------------------------------------------3

More information

NU2 Smart Power Supply (SPS) Manual

NU2 Smart Power Supply (SPS) Manual GENERAL The Smart Power Supply (SPS) is an innovative Quad Output, field programmable power supply. Each of the four outputs can provide four Amps for a total of sixteen Amps in either 12VDC or 24VDC.

More information

Tek-CARE NC110, NC110A Nurse Call System

Tek-CARE NC110, NC110A Nurse Call System Tek-CARE NC110, NC110A Nurse Call System Submittal Package as of 5/25/2017 Phone: 828.524.9967 Toll-Free: 800.327.8466 Sales: Option 2 Tech Support: Option 3 324 Industrial Park Road Franklin, NC 28734

More information

NON-MONITORED EMERGENCY CALL SYSTEMS

NON-MONITORED EMERGENCY CALL SYSTEMS NON-MONITORED EMERGENCY CALL SYSTEMS A non-monitored emergency call system includes a pendant and a control box or phone which is connected to the telephone network (via landline or mobile network). When

More information

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 12/23/16 Rev 9 UltraLITE Model ELU General Specification 4.2 KW to 5 KW UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 1.0 General General Specification This specification describes

More information

TALKAPHONE MASTER CATALOG

TALKAPHONE MASTER CATALOG W W W. TA L K A P H O N E. C O M 773.539.1100 TALKAPHONE MASTER CATALOG THE LEADERS IN SECURITY AND LIFE SAFETY COMMUNICATIONS TABLE OF CONTENTS About Talkaphone... 2-3 Housing Towers... 4-7 Wall Mounts...

More information

RACK MONITORING SYSTEM - RAMOS Ultra

RACK MONITORING SYSTEM - RAMOS Ultra CONTEG DATA SHEET version: 9-05-0 COMPLEMENTARY SYSTEMS RACK MONITORING SYSTEM marketing@dafnia.com www.dafnia.com ABU DHABI UAE +97 55575 DUBAI JAFZA +97 4 5995 +97 4 8840 MUSCAT DOHA OMAN +968 4 75005

More information

3226 Trunk Port FXO Doorphone

3226 Trunk Port FXO Doorphone 3226 Trunk Port FXO Doorphone Installation and User Guide Algo Communication Products Ltd., Burnaby, BC Canada V5J 5L2 www.algosolutions.com - 1 - Document #: 90-00040F Important Safety Notice The 3226

More information

SECTION ELECTRONIC PERSONAL PROTECTION SYSTEM (EPPS)

SECTION ELECTRONIC PERSONAL PROTECTION SYSTEM (EPPS) PART 1 GENERAL 1.1 DESCRIPTION SECTION 28 26 00 Provide and install complete Duress-Panic Alarms, Emergency Phones/ Call-Boxes, and Intercom Systems, hereafter referred to as EPPS System. 1.2 RELATED WORK

More information

NURSE CALL SYSTEM SPECIFICATION

NURSE CALL SYSTEM SPECIFICATION NURSE CALL SYSTEM SPECIFICATION MICRO NURSE CALL SYSTEMS cc 011 499 1145 Members: Jose Da Silva, Wennie Opperman, Vernon Breet INDEX Page 3 - General Description System Components Page 4 - Description

More information

EMERGENCY ASSISTANCE ALARMS

EMERGENCY ASSISTANCE ALARMS Folknoll Group Ltd. EMERGENCY ASSISTANCE ALARMS BS 8300:2009 AND DOCUMENT M COMPLIANT TOUGH, VANDAL RESISTANT IDEAL FOR PUBLIC USE File:DT 7800-018 DS1 V105 Emergency Assistance Product Information.Docx

More information

AlertWave. visiplex. From a Public Address System to an Emergency Communication System... The AlertWave system advantages:

AlertWave. visiplex. From a Public Address System to an Emergency Communication System...  The AlertWave system advantages: AlertWave From a Public Address System to an Emergency Communication System... The AlertWave offers facility managers an easy way to implement an on-site wireless public address, emergency control and

More information

good things in small packages

good things in small packages FireShield Control Panels good things in small packages life safety for small buildings and shops A perfect arrangement FireShield offers the very best conventional fire alarm technology available, with

More information

TX3 Series TX3-CX-1. Installation Manual

TX3 Series TX3-CX-1. Installation Manual TX3 Series TX3-CX-1 Installation Manual Version 0 TX3-CX-1 Installation Manual 1 LT-6618 Copyright October 2017 Copyright October 2017 Mircom Inc. All rights reserved. Mircom TX3-CX-1 Installation Manual

More information

IRIS Connect Series Quick Installation & Maintenance Guide. Version 1.1

IRIS Connect Series Quick Installation & Maintenance Guide. Version 1.1 IRIS Connect Series Quick Installation & Maintenance Guide Version 1.1 Contents 1. Introduction... 4 2. Product Features... 4 3. Package Contents... 5 4. Board Configuration... 5 5. Before You Start...

More information

Signature Series 418 Mhz COMMUNICATOR RECEIVER INSTALLATION AND OPERATIONS MANUAL

Signature Series 418 Mhz COMMUNICATOR RECEIVER INSTALLATION AND OPERATIONS MANUAL Signature Series 418 Mhz COMMUNICATOR RECEIVER INSTALLATION AND OPERATIONS MANUAL General Installation and Operations manual Signature Series 418 Mhz Communicator Receiver and Docking Port Model # BWR-412

More information

Variable Frequency Drive SERIES MP800 VFD

Variable Frequency Drive SERIES MP800 VFD Metron Fire Pump Controls and Accessories Variable Frequency Drive SERIES MP800 VFD Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for

More information

RACK MONITORING SYSTEM RAMOS Ultra

RACK MONITORING SYSTEM RAMOS Ultra version: 7-05-03 CONTEG DATASHEET COMPLEMENTARY SYSTEMS RACK MONITORING SYSTEM CONTEG, spol. s r.o. Czech Republic Headquarters: Na Vítězné pláni 79/4 40 00 Prague 4 Tel.: +40 6 9 8 Fax: +40 6 9 9 Production

More information

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1 Operation Manual Fighter ProVision Software Version: 0.0 Revision: 1 TABLE OF CONTENTS 1. Introduction 5 2. Software Installation 5 3. PC Users 6 3.1 Introduction 6 3.2 Default Code 6 3.3 Edit PC User

More information

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel ACC-25/50ZST Zoned System Voice with Telephone Evacuation Control Panel General The AUDIO COMMAND CENTER 25/50 Zone System with FireFighters Telephone (ACC-25/50ZST) is a state-of-the-art Emergency Voice

More information

T M. User Manual. MarinaGuard. Ground Fault Monitoring Panel For Marina Shore Power

T M. User Manual. MarinaGuard. Ground Fault Monitoring Panel For Marina Shore Power T M User Manual MarinaGuard Ground Fault Monitoring Panel For Marina Shore Power NAE1095810 / 03.2013 T M Bender Inc. USA: 700 Fox Chase Coatesville, PA 19320 Toll-Free: 800-356-4266 Phone: 610-383-9200

More information

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0 User s Guide SUB-MA7240O-0001.OG.Solution40-111.doc Created: 6/05/03 Last Updated: 23/09/03 MA7240AO-0001 Version 1.0 2 Table Of Contents User List...6 Quick Reference..7 Features...7 Keypad User's Guide...8

More information

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock. Preface Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock. The GSM Security Alarm ( The Alarm ) adopts the most advanced

More information

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge. 2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge. Exception: Manual fire alarm boxes are not required where the building is

More information

NFPA Siemens Industry, Inc. All rights reserved. usa.siemens.com/infrastructure-cities

NFPA Siemens Industry, Inc. All rights reserved. usa.siemens.com/infrastructure-cities Fire Alarm and Signaling Code Overview NFPA 72-2010 usa.siemens.com/infrastructure-cities Siemens Building Technologies, Inc. is a Registered Provider with The American Institute of Architects Continuing

More information

Now Compa ble With. VL Touchscreen Alarm. Crafted Touchscreen Security System that Revolutionizes Your World. illi tl C

Now Compa ble With. VL Touchscreen Alarm. Crafted Touchscreen Security System that Revolutionizes Your World. illi tl C Now Compa ble With VL Touchscreen Alarm V AB Brilliantly illi tl C Crafted Touchscreen Security System that Revolutionizes Your World Crafted with Incredible Intelligence Introducing the new VL touchscreen

More information

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information: RDM LOCK G-1 1400 Series Electromagnetic Lock The patented 1400 Series Electromagnetic Lock is universal for all types of applications, including outdoor use. The innovative design will reduce installation

More information

Soft Start Series MP700 Solid State, Reduced Voltage

Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controls and Accessories Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s

More information

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS GENERAL DESCRIPTION... 2 STANDARD AND OPTIONAL PARTS LIST... 2 PARTS DIAGRAM... 3 TERMINAL DRAWING AND SPECIAL NOTES...

More information

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description.

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description. Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description The TYCO RAPID RESPONSE Model RCP-1 Residential

More information

Intelligent addressable fire alarm control panel

Intelligent addressable fire alarm control panel Intelligent addressable fire alarm control panel Input current consumption: Panel rating: Batteries: Networking and Interfaces Panel to panel communication: Number of panels: Interface port: System capacity

More information

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906 s Data Sheet Fire Safety & Security Products SXL-EX Fire Alarm Control Panel Conventional Zone Fire Alarm Control Panel ARCHITECT AND ENGINEER SPECIFICATIONS Four (4) zones expandable to eight (8) zones

More information

Measuring Recording Online Monitoring Regulation Alarming

Measuring Recording Online Monitoring Regulation Alarming Measuring Recording Online Monitoring Regulation Alarming Temperature Humidity CO 2 Dew point Atmospheric pressure Analog signals Two-state inputs Pulses Battery operated recorders and printers Economical

More information

AlertWave Smart Wireless Solutions for Today s Campus Whether you are a large university

AlertWave Smart Wireless Solutions for Today s Campus Whether you are a large university Introduction AlertWave Smart Wireless Solutions for Today s Campus Whether you are a large university seeking a comprehensive packaged solution or a community college looking for a detailed solution on

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. Minimum lighting control (base scope of work) shall include all corridors. The lighting in all the corridors shall be turned on (if not already on) if

More information

Panel XTO210/610/710 GPRS

Panel XTO210/610/710 GPRS P r o d u c t S p e c i f i c a t i o n s S h e e t Doc. - Ref. 220-XTO Version : Juin 2013 Description Supervised Wireless Technology The XTO control panel is a Videofied weatherproof, wireless, battery

More information

Elderly Care Alarm System

Elderly Care Alarm System Introduction 24/7 Peace of mind for your family The GSM Elderly Care Alarm System is a new released smart solution for take care of senior, aged, elder or disabled people on their daily life. Big LED display

More information

Independent Zone Control (I.Z.C.)

Independent Zone Control (I.Z.C.) Operation and Installation Guide Independent Zone Control (I.Z.C.) DELAYED INSTANT ARMED 1 2 3 4 7 5 6 8 9 * * fi Radionics R D279A Operation & Installation Guide 46456B Page 2 Copyright 2000 Radionics

More information

Architectural and Engineering Specification for a. Flash / Flare

Architectural and Engineering Specification for a. Flash / Flare Architectural and Engineering Specification for a Flash / Flare June 27, 2014 Page 1 of 12 T1DA0115-001 Rev D This document is intended to provide performance specifications and operational requirements

More information

Print Specification. Publication. Instructions. Specific requirements. General requirements

Print Specification. Publication. Instructions. Specific requirements. General requirements Print Specification Publication GSA-CC1 Single Input Signal Module Installation Sheet P/N P-047550-1802-EN REV 04 ISS 23JUN15 Instructions This page is the print specification for the publication. It is

More information

abode Web app Functionality

abode Web app Functionality abode Web app Functionality System mode display controls the state of the alarm system. The user can change the mode of the system by simply clicking on the desired mode. When arming the system with the

More information

Solution for the complete management of the Hospital. Shaping communication solutions beyond the obvious

Solution for the complete management of the Hospital. Shaping communication solutions beyond the obvious H O S P I TA L S Solution for the complete management of the Hospital Shaping communication solutions beyond the obvious the most complete solution on the market HELPNEX IP is the most complete healthcare

More information