Home Fire Sprinkler. Display Guide USE THIS KIT TO CUSTOMIZE THE HOME FIRE SPRINKLER DISPLAY TO MATCH THE REQUIREMENTS IN YOUR JURISDICTION.

Size: px
Start display at page:

Download "Home Fire Sprinkler. Display Guide USE THIS KIT TO CUSTOMIZE THE HOME FIRE SPRINKLER DISPLAY TO MATCH THE REQUIREMENTS IN YOUR JURISDICTION."

Transcription

1 Home Fire Sprinkler Display Guide A COMPLETE GUIDE TO BUILDING AND USING A NFPA 13D DISPLAY TO EDUCATE YOUR COMMUNITY USE THIS KIT TO CUSTOMIZE THE HOME FIRE SPRINKLER DISPLAY TO MATCH THE REQUIREMENTS IN YOUR JURISDICTION.

2 TABLE OF CONTENTS INTRODUCTION > 3 DISPLAY MATERIALS YOU LL NEED > 4 PREFERRED TOOLS LIST > 5 SIGNAGE YOU LL NEED > 6 FRAME CONSTRUCTION OVERVIEW > 7 DISPLAY COMPONENT PREPARATION > 8 SHORT WALL ASSEMBLY > 9 LONG WALL ASSEMBLY > 10 TOP ASSEMBLY > 11 UNIT ASSEMBLY > 12 RISER INSTALLATION OVERVIEW > 13 RISER INSTALLATION MATERIAL LIST > D RISER 3D VIEW - BYPASS METERS > 16 TOP VIEW - BYPASS METER > 17 FRONT VIEW - BYPASS METER > 18 SIDE VIEW - BYPASS METER > 19 SIGNAGE INSTALLATION > 20 USING YOUR HOME FIRE SPRINKLER DISPLAY >

3 INTRODUCTION The Home Fire Sprinkler Display Kit contains instructions for building a portable display that shows the inner workings of an NFPA 13D home fire sprinkler system, various sprinkler options and how to do a flow test. It can be customized to match local system requirements. Refer to page 21 for ideas on using the display to improve home fire sprinkler awareness in your community. The display can be constructed by personnel with moderate to good carpentry skills. Riser installation should only be done by an qualified home fire sprinkler installer. The nonprofit Home Fire Sprinkler Coalition (HFSC) is a 501(c)(3) charitable educational organization and the leading resource for independent, noncommercial information about residential fire sprinklers. HFSC was formed in 1996 in response to the tremendous need to inform the public about the lifesaving value of home fire sprinkler protection. Development of this kit was funded through a grant from State Farm. HFSC thanks Tom Lia and the Northern Illinois Fire Sprinkler Advisory Board for technical assistance. 3

4 DISPLAY MATERIALS YOU'LL NEED (1) 1/4" x 4' x 8' plywood (paint white on one side) (6) 2" x 4" x 8' (7) 2" x 6" x 8' (1) 2" x 10" x 8' (4) 2" Medium Duty Caster Wheels (1) box 11/4" Screws (1) box 3" Screws (1) box of sheet metal screws (1) pint of white paint (1) paintbrush or paint roller (1) paint tray (1) 31/4" x 10" x 5' HVAC Duct Work (optional) (1) Box 11/4" common nails or gun nails Zip ties or double stick tape for signage attachment Literature holder 4

5 PREFERRED TOOLS LIST Table saw (preferred) or circular saw Miter saw for angular cuts Jig saw for curved cuts (optional) Impact driver for drywall screws Hammer or nail gun Square Tape measure Hole saw 21/4" 2 saw horses Power drill with screwdriver bit 5

6 SIGNAGE YOU'LL NEED Concealed Pendant Sprinkler Concealed Sidewall Sprinkler Pendant Fire Sprinkler Sidewall Sprinkler 6" Inside Alarm Bell (NFPA 13D Option) Spare Fire Sprinkler Box Water Flow Switch (NFPA 13D Option) Fire Sprinkler Pipe Inspector Test Valve HVAC Duct Work (optional) Backflow Preventer (NFPA 13D Option) Sump Pump Floor Drain Pressure Gauge Control Valve Underground Water Supply Potable Water Supply Water Meter Department Information 6

7 FRAME CONSTRUCTION OVERVIEW Construction of the display frame starts with cutting the individual components to the correct length and angles. The components are then assembled into a Long Wall, Short Wall and the Top. Finally the three pieces are assembled into the display frame. In addition there are flat panels that simulate the home's drywall. These panels can be either square cut or curved cut depending on preference. Optional HVAC duct work can be added, particularly if the mounting of a fire sprinkler alarm is to be demonstrated. 7

8 DISPLAY COMPONENT PREPARATION Construction should begin by cutting out each of the components. It is helpful to layout the components as they are finished. SQUARE CUT PIECES Cut (4) two-by-fours to 68" Cut (2) two-by-fours to 32" Cut (2) two-by-sixes to 29" Cut (4) two-by-sixes to 68" Cut (1) two-by-six to 441/2" Cut (1) two-by-six to 48" Cut (1) two-by-six to 4" Cut (1) two-by-ten to 441/2" ANGLE CUT PIECES Cut (1) two-by-four to 493/4" with 65 and 22 end cuts (see illustration) Cut (1) two-by-six to 463/4" with 22 end cuts (see illustration) Cut (1) two-by-six to 241/2" with 90 and 22 end cuts (see illustration) Cut (1) two-by-six to 181/4" with 90 and 22 end cuts (see illustration) 2" X 4" " Cut (1) two-by-six to 111/4" with 90 and 22 end cuts (see illustration) 2" X 6" PLYWOOD PANEL PIECES " 22 Paint one side of 4' x 8' panel white and let dry " " 90 Cut (2) 12" X 441/2" panels Cut (2) 12" X 261/4" panels " Cut (1) 12" X 281/2" panel 8

9 SHORT WALL ASSEMBLY 16 on center 1. On saw horses, lay out (4) 68" two-by-four studs 16", 101/2" and 51/2" on center. 2. Attach (1) 32" two-by-four stud to each end using 3" screws. 10½ on center 5½ on center

10 LONG WALL ASSEMBLY 1. On saw horses, layout (4) 68" two-by-six studs 16", 16" and 121/2" on center. 16 on center 2. Attach (1) 441/2" two-by-six stud to top of studs using 3" screws. 3. Attach (1) 441/2" two-by-ten stud to bottom of studs using 3" screws. Align the studs along the back edge of the two-by-ten. 16 on center 12½ on center 44½ 68 10

11 4" TOP ASSEMBLY 1. On saw horses, lay out (1) 48" twoby-six stud. 46¾" 2. Attach (1) 29" two-by-six stud to end using 3" screws. 3. Attach (1) 4" two-by-six stud to end using 3" screws. 4. Attach (1) 29" two-by-six stud to connect 4" and 48" studs using 3" screws. 29" 24" 18¼" 11¼" 5. Attach (1) 141/2" angle cut two-bysix stud to other end of 48" stud using 3" screws. 6. Attach (1) 463/4" angle cut two-bysix stud to connect 141/2" and 29" studs using 3" screws. 48" 7. Slide (1) 241/2" angle cut two-bysix stud and (1) 181/4" angle cut two-by-six stud into position (see illustration) and attach using 3" screws. 11

12 UNIT ASSEMBLY 1. Place Long Wall on sawhorses backside down. 2. Position Short Wall as shown. 3. Attach using 3" screws. 4. Position (1) 493/4" angle cut twoby-four as shown. 5. Attach using 3" screws. 6. Position Top as shown. 7. Attach using 3" screws. 8. Attach (4) casters to bottom as shown using 11/4" screws. 9. Attach (5) plywood panels whiteside out as shown using 11/4" screws or nails (optional). 10. Stand Unit upright. 11. Attach HVAC duct work as shown using 11/4" screws (optional). 12. Install smoke alarm. Steps 1-3 Steps 6-7 Steps 4-5 Step 8 Step 9 Steps Step 12 12

13 RISER INSTALLATION OVERVIEW The Riser should be installed by an qualified fire sprinkler installer using the following diagrams. The drawings illustrate installing the riser bypassing the water meter. If local ordinances require the meter to be inline, adapt the installation to reflect that. 13

14 THE HFSC FIRE AND SPRINKLER BURN DEMONSTRATION KIT RISER INSTALLATION MATERIAL LIST ITEM # QUANTITY DESCRIPTION 1 (1) Water Meter 2 (1) Domestic Shutoff Valve 3 (1) Double Check Valve Assembly 4 (1) 1" x 0'-4" Blk Sch 40 Nipple 5 (1) 1" D.I. Threaded 90 Degree Elbow 6 (2) 1" x 1'-4" Black Sch. 40 Pipe 7 (2) 1" D.I. Threaded Tee 8 (1) 1" Flow Switch - Optional 9 (2) 1" x 0'-4" Blk Sch 40 Nipple 10 (1) 1" Test and Drain Valve w/orifice = to smallest sprinkler 11 (1) 1" x 1" x 1/2" D.I. Threaded Tee 12 (1) 1/2" x 1/4" D.I. Threaded Bushing 13 (1) 1/4" x 0'-2" Brass Nipple 14 (1) 1/4" 3-Way Valve 15 (1) 1/4" Brass Plug 16 (1) 1/4" Pressure Gauge - Optional 17 (1) 1" x 0'-8" Black Sch. 40 Pipe 18 (1) 1" Steel to CPVC Adapter cont'd 14

15 THE HFSC FIRE AND SPRINKLER BURN DEMONSTRATION KIT RISER INSTALLATION MATERIAL LIST cont'd 19 (1) 1" x 0'-10" CPVC Pipe 20 (4) 1" CPVC (1) 1" x 0'-3" CPVC Pipe 22 (2) 1" x 0'-9" CPVC Pipe 23 (2) 1" CPVC Tee 24 (2) 1" x 0'-3" CPVC Pipe 25 (1) 1" x 1" x 1/2" Sprinkler Head Tee 26 (2) 1" x 0'-6" CPVC Pipe 27 (3) 1" x 1/2" Sprinkler Head (2) 1" x 1'-3" CPVC Pipe 29 (1) 30 (1) 31 (1) 32 (1) 1/2" Residential Concealed Sidewall Sprinkler 1/2" Residential Semi-Recessed Sidewall Sprinkler 1/2" Residential Concealed Pendent Sprinkler 1/2" Residential Semi-Recessed Pendent Sprinkler 33 (1) 6" Alarm Bell Optional 34 (1) Emergency Sprinkler Cabinet with Wrench Optional 35 (10) 1" No-Block CPVC Pipe Hanger 15

16 13D RISER 3D VIEW - BYPASS METER 16

17 TOP VIEW - BYPASS METER 17

18 FRONT VIEW - BYPASS METER 18

19 SIDE VIEW - BYPASS METER 19

20 SIGNAGE INSTALLATION Place the signs on the appropriate components using zip ties or double stick tape. Local fire departments can create and post their own sign that includes their contact information; Fire Department name and logo, address, phone number, address, website address, QR Code, etc. 20

21 USING YOUR HOME FIRE SPRINKLER DISPLAY Now that you ve assembled your display, it s time to plan how you ll use it. The display is portable and it works with a wide range of audiences and many types of events. Here are some examples: COMMUNITY EVENTS State Fair Home Shows and Building Trade Shows Fire Prevention Week Activities Safety Fair Fire Station Open Houses SCHOOL ACTIVITIES Vocational-technical high school competitions Parent-Teacher conferences Safety Day HOMEBUILDERS Partner with a homebuilder who offers sprinklers as a way to educate during open houses. Bring the display to area chapter meetings of your local homebuilders association to accompany your presentation. MUNICIPAL ACTIVITIES Present the display at the Building Department so homebuilders can see it when they bring plans in for approval. Get on the agenda of your Planning and Zoning Boards and bring the display to explain the value of trade ups to encourage sprinklering of new developments. Present the display at your Town/Village Hall. Share the display during Town/Village meetings, elections and other public events. 21

22 USING YOUR HOME FIRE SPRINKLER DISPLAY cont'd USE THE DISPLAY TO EDUCATE OTHER PROFESSIONALS AT THEIR OFFICES AND MEETINGS Insurance agents Real Estate agents Water suppliers OTHER FIRE DEPARTMENTS The portability of this display is one of its best features. If there are other departments near your jurisdiction, offer to share your display when they have public education opportunities in their jurisdictions. EVALUATE THE DISPLAY S EFFECTIVENESS It s important to know whether public education work is effective and to make changes to improve it. Evaluation is also important (often essential) in order to obtain municipal and grant funding. Pre- and posttests give you a quick answer to how much your audience learned after their exposure to the Display. Using these tests is an easy way to help you determine how well the display meets your educational goals. You can modify these sample test questions based on your audience and the purpose for using the display. Please share your evaluation results with HFSC so we can improve the resources we create and offer to the fire service. SAMPLE PRE- AND POST-TEST 1. Do you have fire sprinklers installed at home? Yes/No 2. Would you buy a home with fire sprinklers installed? Yes/No/Maybe 3. True or False: Home fire sprinklers are triggered by the smoke alarm. 4. True or False: If fire breaks out, all the fire sprinklers flow water at once. 5. True or False: Home fire sprinklers work automatically, preventing flashover and controlling the heat, smoke and flames until the fire department arrives. MEDIA When you bring the display to a public event, inform your local media ahead of time to encourage coverage of this public safety activity. Let them know that you will be providing a unique hands-on educational resource for the event s audience. Be sure to mention that the Display makes a great visual backdrop for print and television. 22

23 USING YOUR HOME FIRE SPRINKLER DISPLAY cont'd GET LOCAL HELP FOR YOUR DISPLAY If your jurisdiction doesn t have the budget to purchase the construction materials, reach out to businesses and groups for funding. Be sure to publicly thank your sponsors during events, in local media coverage and you may want to post the names and logos of your sponsors on the side of the display. HERE ARE SOME IDEAS: Sprinkler Contractors You ll need to partner with a sprinkler contractor experienced in NFPA 13D installations to build the Display. They may also be able to help you acquire the sprinkler components by sharing their industry contacts. Lumberyards/Big Box Stores Call the manager at your local retailer and request to meet him/her at the store. Bring the list of tools and construction materials and be prepared to explain what the display is and how it can be used to conduct life safety education in your community. Ask the manager if there are any tools or materials that the store can donate to support this permanent public safety resource. Offer store name and logo recognition in return for their support. Insurance Companies If your local residential property insurers offer a discount for homes protected by fire sprinklers, contact area offices to request a donation and/ or participation in your educational events. (Note: State Farm is HFSC s sponsor for this display but you can work with any home insurer.) 23

Now That You re Living With Sprinklers

Now That You re Living With Sprinklers Now That You re Living With Sprinklers Fire Sprinklers Save Lives When a fire starts, its high temperature causes the fire sprinkler closest to the fire to spray water. The water quickly controls deadly

More information

HOME FIRE SPRINKLER SYSTEMS. the future of fire safety here today

HOME FIRE SPRINKLER SYSTEMS. the future of fire safety here today HOME FIRE SPRINKLER SYSTEMS the future of fire safety here today UNDERSTANDING FIRE SPRINKLER PROTECTION FOR HOMES Fire kills more people in the United States annually than all natural disasters combined.

More information

HELP THEM PROTECT THEIR WORLD.

HELP THEM PROTECT THEIR WORLD. HELP THEM PROTECT THEIR WORLD. SAVE LIVES PROTECT PROPERTY REDUCE DEVELOPMENT COSTS INCREASE PROFIT OPPORTUNITY CREATE A COMPETITIVE ADVANTAGE HOME BUYERS ARE LOOKING UP TO TYCO FOR STATE-OF-THE-ART FIRE

More information

HOME FIRE SPRINKLER SYSTEMS. fire safety. the future of. here today

HOME FIRE SPRINKLER SYSTEMS. fire safety. the future of. here today HOME FIRE SPRINKLER SYSTEMS the future of HFSC-FutureBro-17.indd 1 fire safety here today UNDERSTANDING FIRE SPRINKLER PROTECTION FOR HOMES Fire kills more people in the United States annually than all

More information

FIRE SUPPRESSION SPRINKLER SYSTEM

FIRE SUPPRESSION SPRINKLER SYSTEM PART 1 GENERAL 1.01 DESCRIPTION A. The provisions of the General Requirements, Supplementary Requirements, and Division 1 apply to the plumbing work specified in this Division. B. The requirements of this

More information

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8 City of Ottawa Project No. CR006230 Page 1 of 8 PART 1 - GENERAL 1.1 Reference Standards.1 Conform to the following:.1 Provincial and municipal building and fire regulations as approved by Provincial Fire

More information

Specialties Quality, Durability, Reliability. FIrE ProTECTIon

Specialties Quality, Durability, Reliability. FIrE ProTECTIon _specialties:pcsectiond_new 2/6/2012 4:46 PM Page -36 36 SECTIon Specialties Quality, Durability, Reliability FIrE ProTECTIon In addition to our plumbing business, LYNCAR has been a leading supplier to

More information

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry Plan Review

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry Plan Review MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry Plan Review Minooka Fire Protection District Maintaining Your Fire Safety Systems Fire continues to be a major threat

More information

SECTION WET PIPE FIRE PROTECTION SPRINKLER SYSTEM

SECTION WET PIPE FIRE PROTECTION SPRINKLER SYSTEM SECTION 213100 WET PIPE FIRE PROTECTION SPRINKLER SYSTEM PART 1 - GENERAL 1.01 GENERAL REQUIREMENTS A. The requirements of the General Conditions and Supplementary Conditions apply to all work herein.

More information

Chapter 4: Fire Protection Systems

Chapter 4: Fire Protection Systems Chapter 4: Fire Protection Systems Automatic Extinguishing Systems (Fire Sprinklers) One of the most important aspects of a storage warehouse inspection is ensuring that the automatic extinguishing system

More information

The Benefits of Home Fire Sprinklers

The Benefits of Home Fire Sprinklers The Benefits of Home Fire Sprinklers IN ONE- AND TWO-FAMILY HOMES Rhode Island Sprinkler Coalition Understanding Fire Sprinkler Protection for Homes Fire kills more people in the United States annually

More information

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION SECTION 21 1301- FIRE-SUPPRESSION SYSTEMS PART 1 - GENERAL 1.1 SUMMARY: A. This Section includes fire-suppression piping and equipment for the following building systems: 1. Wet-pipe, fire-suppression

More information

MONTECITO FIRE PROTECTION DISTRICT

MONTECITO FIRE PROTECTION DISTRICT Section 5a MONTECITO FIRE PROTECTION DISTRICT FIRE PROTECTION PLAN Residential Automatic Fire Sprinkler System Installations I Automatic Fire Sprinkler System Standards 1. Definition and Standard: An automatic

More information

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University. 15500 - FIRE PROTECTION PART I DESIGN GUIDELINES A. General 1. Vertical fire pumps shall not be used at the University. 2. coupling piping shall be permitted for sprinkler and standpipe systems only. B.

More information

WALL ESCUTCHEON PIPE SEAL WITH APPROVED FIRE CAULKING (SEE SPECIFICATIONS) NOTE: 12" 12" 24"

WALL ESCUTCHEON PIPE SEAL WITH APPROVED FIRE CAULKING (SEE SPECIFICATIONS) NOTE: 12 12 24 SOUTH TEJON ST., SUITE 00 COLORADO SPRINGS, CO. 00 TELE.: FAX: WALL ESCUTCHEON PACK ANNULAR SPACE WITH MINERAL WOOL GENERAL NOTES. THIS PROJECT INCLUDES THE DESIGN AND PROVISION OF A NEW WET SPRINKLER

More information

HOW COMMERCIAL FIRE PROTECTION SPRINKLER SYSTEMS REALLY OPERATE

HOW COMMERCIAL FIRE PROTECTION SPRINKLER SYSTEMS REALLY OPERATE A Guide for Fire Sprinkler Maintenance and Operation Commercial fire protection sprinkler systems have been saving lives and reducing property damage for more than a century. New England s textile mills

More information

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD Installation of Residential Fire Sprinkler Systems STANDARD #C-002 EFFECTIVE 03-19-2009 PURPOSE: To ensure that sprinkler plans submitted for review contain

More information

Refer to the specific sprinkler or spray nozzle technical data pages for sprinkler listings and approvals.

Refer to the specific sprinkler or spray nozzle technical data pages for sprinkler listings and approvals. Page 1 of 5 1. DESCRIPTION A. Sprinkler Cabinets Viking sprinkler cabinets are metal enclosures constructed to store an emergency supply of spare sprinklers and a sprinkler installation wrench. NFPA 13

More information

New Construction Fire Inspection Process

New Construction Fire Inspection Process New Construction Fire Inspection Process This document is intended to provide the Owner, Designer, and/or Contractor of new construction with an outline of required fire inspections and with the specific

More information

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM SECTION 21 0000 AUTOMATIC FIRE SPRINKLER SYSTEM PART 1 GENERAL 1.1 QUALITY ASSURANCE A. Codes and Standards: 1. FBC (Florida Building Code 2015) 2. FBC (Florida Fire Code 2015) 3. NFPA #13R (Standard for

More information

COBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM

COBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM SECTION 21 10 00 PART 1 - GENERAL 1.1 CODES A. Work shall conform to NFPA 13 Sprinkler Systems, 2002 Edition and NFPA 24 Outside Protection, 2002 Edition. NFPA 14 Standpipe Systems, 2000 Edition and International

More information

Zurn Pex, Inc. Residential Fire Protection Presentation. PEX Plumbing, Radiant Heating and Residential Fire Protection Systems

Zurn Pex, Inc. Residential Fire Protection Presentation. PEX Plumbing, Radiant Heating and Residential Fire Protection Systems Residential Fire Protection Presentation Zurn Pex, Inc PEX Plumbing, Radiant Heating and Residential Fire Protection Systems Matt Lawrence BDM-North Central Region 1 Presentation Outline I. IRC Mandate

More information

NFPA 25 and the Influence of Liability

NFPA 25 and the Influence of Liability NFPA 25 and the Influence of Liability NFPA 25 Summit Addison, IL Northern Illinois Fire Sprinkler Advisory Board/ Illinois Fire Inspectors Association Date: Speaker: July 28, 2017 Michael J Bosma Meet

More information

Illinois Fire Safety Alliance

Illinois Fire Safety Alliance The Benefits of Home Fire Sprinklers Illinois Fire Safety Alliance www.ifsa.org 847-390-0911 The Problem: Home Fires Fire kills more people in the United States annually than all natural disasters combined,

More information

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements. FIRE PROTECTION GENERAL INFORMATION 1.1 Refer to Section 230000 for General Mechanical Requirements. 1.2 Refer to Section 230529 for Hangers and Supports. 1.3 Refer to Section 230553 for Pipe and Equipment

More information

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant. SECTION 218800 - FIRE PROTECTION 1. GENERAL A. Provisions of Division 1, GENERAL REQUIREMENTS, and Section 230000, MECHANICAL GENERAL CONDITIONS, and Section 230050, SEISMIC PROTECTION are a part of this

More information

1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following:

1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following: SECTION 21 10 00 - WATER-BASED FIRE-SUPPRESSION PART I - GENERAL 1.1 SUMMARY A. Inclusion of sprinkler and standpipe systems shall be as determined by NFPA National Fire Code pamphlet 101 and program statement.

More information

The Benefits of Home Fire Sprinklers IN ONE- AND TWO-FAMILY HOMES

The Benefits of Home Fire Sprinklers IN ONE- AND TWO-FAMILY HOMES The Benefits of Home Fire Sprinklers IN ONE- AND TWO-FAMILY HOMES NH Coalition Brochure.indd 1 Understanding Fire Sprinkler Protection for Homes Fire kills more people in the United States annually than

More information

SECTION SPRINKLER SYSTEMS

SECTION SPRINKLER SYSTEMS SECTION 15325 SPRINKLER SYSTEMS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Wet-pipe sprinkler systems. B. Preaction sprinkler systems. C. System design, installation, and certification. D. Fire department

More information

The Benefits of Home Fire Sprinklers IN ONE- AND TWO-FAMILY HOMES

The Benefits of Home Fire Sprinklers IN ONE- AND TWO-FAMILY HOMES The Benefits of Home Fire Sprinklers IN ONE- AND TWO-FAMILY HOMES NC Coalition Brochure2.indd 1 Understanding Fire Sprinkler Protection for Homes Fire kills more people in the United States annually than

More information

Sheetz Inc. Fire Protection Service Guidelines

Sheetz Inc. Fire Protection Service Guidelines Sheetz Inc. Fire Protection Service Guidelines Overview The following are guidelines for Sheetz Fire Protection Services for the 2016/2018 contract year. Each key area is listed below with the appropriate

More information

CEILINGS BACKSPLASHES WALLS PROJECTS INSTALLATION GUIDE.

CEILINGS BACKSPLASHES WALLS PROJECTS INSTALLATION GUIDE. CEILINGS BACKSPLASHES WALLS PROJECTS INSTALLATION GUIDE Installation videos available online at: /videos Ceiling Components: A tin ceiling is comprised of two primary components and two optional components.

More information

Contren Learning Series Apprenticeship Training Program for Fire Sprinkler Fitters

Contren Learning Series Apprenticeship Training Program for Fire Sprinkler Fitters Contren Learning Series Apprenticeship Training Program for Fire Sprinkler Fitters (Published jointly by American Fire Sprinkler Association and the National Center for Construction Education and Research.)

More information

RESIDENTIAL FIRE SPRINKLER SYSTEMS POLICY

RESIDENTIAL FIRE SPRINKLER SYSTEMS POLICY RESIDENTIAL FIRE SPRINKLER SYSTEMS POLICY Plan Submittal and Inspection Requirements Revised 01/18/18 All residential fire sprinkler systems within the jurisdiction of the Fire Department shall meet all

More information

Montgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040

Montgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040 Montgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040 SPRINKLER SHOP DRAWINGS 2007 NFPA 13 and 2007 NFPA 24 Project: Listed items require sprinkler

More information

City of Attleboro, Massachusetts WATER DEPARTMENT Government Center, 77 Park Street Attleboro, Massachusetts Phone Fax

City of Attleboro, Massachusetts WATER DEPARTMENT Government Center, 77 Park Street Attleboro, Massachusetts Phone Fax APPLICATION FOR BACKFLOW PREVENTION DEVICE PERMIT PLAN REVIEW Application & Permit Fee: $50.00 APPLICANT INFORMATION OWNER INFORMATION (if different from applicant): CONTRACTOR OR PLUMBER INFORMATION:

More information

DRY VERTICAL SIDEWALL SPRINKLERS TECHNICAL DATA

DRY VERTICAL SIDEWALL SPRINKLERS TECHNICAL DATA Page 1 of 6 1. DESCRIPTION Viking dry vertical sidewall sprinklers are suitable for use in areas subject to freezing. They may be installed either upright or pendent, and are suitable for use on dry systems,

More information

TECHNICAL DATA. 2. LISTINGS AND APPROVALS NOTE: Viking Dry Vertical Sidewall Sprinklers are NOT listed or approved. Sprinkler 103a.

TECHNICAL DATA. 2. LISTINGS AND APPROVALS NOTE: Viking Dry Vertical Sidewall Sprinklers are NOT listed or approved. Sprinkler 103a. September 6, 2012 Sprinkler 103a 1. DESCRIPTION Viking are suitable for use in areas subject to freezing. They may be installed either upright or pendent, and are suitable for use on dry systems, preaction

More information

Environmental Health & Safety

Environmental Health & Safety Environmental Health & Safety Oklahoma State University FIRE SPRINKLER SYSTEM STANDARD Environmental Health and Safety University Health Services Suite 002 Stillwater, OK 74078 (405) 744-7241 www.ehs.okstate.edu

More information

A. This section includes design and performance information for fire protection and suppression systems.

A. This section includes design and performance information for fire protection and suppression systems. SECTION 21 00 10: FIRE PROTECTION SYSTEM DESIGN 1. SUMMARY A. This section includes design and performance information for fire protection and suppression systems. 2. GENERAL A. All fire protection materials

More information

Inspection of Fire Sprinkler Systems. NFPA 25, Inspection, Testing & Maintenance of Water Based Fire Protection Systems

Inspection of Fire Sprinkler Systems. NFPA 25, Inspection, Testing & Maintenance of Water Based Fire Protection Systems Inspection of Fire Sprinkler Systems NFPA 25, Inspection, Testing & Maintenance of Water Based Fire Protection Systems Objective To familiarize Facility Managers with the process of routine inspection

More information

MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS

MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS Introduction When properly installed and maintained, automatic fire sprinkler systems have proven to be the most effective means for protecting life and

More information

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA August 14, 2013 Sprinkler 126k 1. PRODUCT DESCRIPTION Viking Institutional Style Quick Response Flush Horizontal Sidewall Sprinklers are small, flush, solder link and lever sprinklers made with tamper-resistant

More information

Gas Station & C Store SECTION CWM Job No

Gas Station & C Store SECTION CWM Job No SECTION 21 1300 - PART 1 - GENERAL 1.1 WORK INCLUDED A. Provide labor, materials, equipment and services to perform operations required for the complete installation and related Work as required in Contract

More information

RESIDENTIAL MULTI-USE FIRE SPRINKLER SYSTEMS PERMIT SUBMITTAL REQUIREMENTS

RESIDENTIAL MULTI-USE FIRE SPRINKLER SYSTEMS PERMIT SUBMITTAL REQUIREMENTS History: RESIDENTIAL MULTI-USE FIRE SPRINKLER SYSTEMS PERMIT SUBMITTAL REQUIREMENTS Per the City adopted 2009 IRC, section R313, automatic fire sprinkler systems are required for all one and two family

More information

Skilled Healthcare Documentation Requirements Life Safety and Fire Protection

Skilled Healthcare Documentation Requirements Life Safety and Fire Protection DATE OF EVALUATION: FACILITY NAME: FACILITY ADDRESS: ADMINISTRATOR: MAINTENANCE DIRECTOR: All required documentation must be written and saved for at least 2 years and some documentation may be required

More information

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE SECTION 21 1316 DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE PART 1 GENERAL 1.01 SECTION INCLUDES A. Dry-pipe sprinkler system. B. System design, installation, and certification. C. Fire department

More information

Residential Fire Protection Sprinklers & Systems

Residential Fire Protection Sprinklers & Systems Residential Fire Protection Sprinklers & Systems Product Guide LFII Residential Sprinklers Sprinkler System Components CPVC Pipe & Fittings Specific Application Attic Sprinklers LFP Antifreeze for Fire

More information

SECTION FIRE PROTECTION. A. Examine all conditions as they exist at the project, prior to submitting a bid for the work of this section

SECTION FIRE PROTECTION. A. Examine all conditions as they exist at the project, prior to submitting a bid for the work of this section PART 1 - GENERAL 1.00 GENERAL PROVISIONS A. Examine all conditions as they exist at the project, prior to submitting a bid for the work of this section 1.01 DESCRIPTION OF WORK A. Work Included: Provide

More information

Deluge/Preaction Systems Annotated Instructor s Guide

Deluge/Preaction Systems Annotated Instructor s Guide Deluge/Preaction Systems Annotated Instructor s Guide Module 18301-07 Module Overview This module covers different types of preaction and deluge systems. It discusses deluge valves, auxiliary detection

More information

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE SECTION 21 1316 DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE PART 1 GENERAL 1.01 SECTION INCLUDES A. Dry-pipe sprinkler system. B. System design, installation, and certification. C. Fire department

More information

Deluge/Preaction Systems Annotated Instructor s Guide

Deluge/Preaction Systems Annotated Instructor s Guide Deluge/Preaction Systems Annotated Instructor s Guide Module 18301-13 Module Overview This module covers different types of preaction and deluge systems. It discusses deluge valves, auxiliary detection

More information

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA Sprinkler 126k Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. PRODUCT DESCRIPTION Viking Institutional Style Quick Response Flush Horizontal

More information

Revision May All designs must be submitted to FM Global for review and approval prior to issuing such for bids.

Revision May All designs must be submitted to FM Global for review and approval prior to issuing such for bids. SECTION 211300 FIRE SUPPRESSION SYSTEMS 1.0 All new and renovated buildings shall be provided with automatic sprinklers throughout and fire standpipe systems. The design and installation of these systems

More information

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL SECTION 21 13 16 DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section

More information

Sprinkler Permit Applications

Sprinkler Permit Applications REQUIREMENTS FOR NFPA 13 SYSTEM Building Inspections Sprinkler Permit Applications A complete application for a Sprinkler Permit will comply with the requirements of Chapter 8 of NFPA 13. Hydraulic calculations

More information

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE SECTION 21 1313 WET-PIPE SPRINKLER SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. Wet-pipe sprinkler system. B. System design, installation, and certification. C. Fire department connections. 1.02 RELATED

More information

FIRE SPRINKLER SYSTEMS POLICY

FIRE SPRINKLER SYSTEMS POLICY FIRE SPRINKLER SYSTEMS POLICY Revised 1/1/17 DESIGN AND SUBMITTAL REQUIREMENTS All new and existing fire sprinkler systems within the jurisdiction of the City Fire Department shall meet all of the applicable

More information

FIRE INSPECTORS GUIDELINES FOR PLAN REVIEWS AND INSPECTIONS OF NEW CONSTRUCTION / ADDITIONS AND CHANGE OF OCCUPANCY

FIRE INSPECTORS GUIDELINES FOR PLAN REVIEWS AND INSPECTIONS OF NEW CONSTRUCTION / ADDITIONS AND CHANGE OF OCCUPANCY FIRE INSPECTORS GUIDELINES FOR PLAN REVIEWS AND INSPECTIONS OF NEW CONSTRUCTION / ADDITIONS AND CHANGE OF OCCUPANCY PLAN REVIEWS SITE PLANS: 1) Access to buildings (Volume V NC Building Code sections 602.6.1

More information

173 Index of Materials

173 Index of Materials 73 Index of Materials IBC Tank 9 Polystyrene Sheet 2 200 Litter Blue Barrels 0 Plumbers Tape (Teflon) 3 Fish Tank Shading Cable Ties 4 Plastic Net 2 Waterproof Eclectic Box 5 Concrete Blocks 3 0 mm Wide

More information

VILLAGE OF DOWNERS GROVE Report for the Village Council Meeting

VILLAGE OF DOWNERS GROVE Report for the Village Council Meeting ORD 2017-7420 Page 1 of 8 VILLAGE OF DOWNERS GROVE Report for the Village Council Meeting SUBJECT: Adoption of 2015 ICC Building and Fire Codes SUBMITTED BY: Stan Popovich, AICP Director of Community Development

More information

INSTITUTIONAL QUICK RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) TECHNICAL DATA

INSTITUTIONAL QUICK RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) TECHNICAL DATA Page 1 of 8 1. PRODUCT DESCRIPTION Viking Institutional Style Quick Response Standard Coverage/Extended Coverage Flush Pendent Sprinklers are small, flush, solder link and lever sprinklers made with tamper-resistant

More information

FIRE SPRINKLER SYSTEMS POLICY

FIRE SPRINKLER SYSTEMS POLICY FIRE SPRINKLER SYSTEMS POLICY VERSION 1.012/2015 FIRE SPRINKLER SYSTEMS Design and Submittal requirements All new and existing fire sprinkler systems within the jurisdiction of the City of San Mateo Fire

More information

Model G5-56 Dry (SIN RA5114) K5.6 (80 metric) Concealed Dry Pendent Sprinkler

Model G5-56 Dry (SIN RA5114) K5.6 (80 metric) Concealed Dry Pendent Sprinkler UL Quick Response FM Standard Response ½ (13mm) Cover plate Adjustment Features 1. Flat cover plate with threaded attachment. 2. Solid or perforated cover plate available in chrome and white as Standard

More information

UNIVERSITY OF MISSOURI Fire Protection System Design 2016 Q1

UNIVERSITY OF MISSOURI Fire Protection System Design 2016 Q1 GENERAL: 1. All fire protection systems shall be installed in accordance with the International Fire Code and applicable NFPA standards. This guideline provides additional requirements for the design and

More information

2009 International Residential Code Draft of New Fire Sprinkler Related Requirements

2009 International Residential Code Draft of New Fire Sprinkler Related Requirements 1. IRC Sections R313 and R314, insert two new sections as follows: R313 FIRE SPRINKLER SYSTEM FOR TOWNHOUSES R313.1 Required Installation. An automatic residential fire sprinkler system shall be installed

More information

CONSTRUCTION REQUIREMENTS

CONSTRUCTION REQUIREMENTS CONSTRUCTION REQUIREMENTS Note: The buildings on the UCCS campus are divided into two categories: General Fund and Auxiliaries. General Fund Buildings include academic and administrative functions. Auxiliary

More information

Component #1. Tiny House Design Plan

Component #1. Tiny House Design Plan Component #1 Tiny House Design Plan Directions: You will complete this handout to help you plan out the design of your tiny house. Your tiny house needs to be within 100 400 square feet. 1. Size of Tiny

More information

Port of St Helens SIA Aircraft Hanger Scappoose, OR

Port of St Helens SIA Aircraft Hanger Scappoose, OR Port of St Helens SIA Aircraft Hanger Scappoose, OR AUTOMATIC FIRE SPRINKLER SYSTEM REVISION 2 MARCH 12, 2018 Scope: Furnish and install foam and water fire protection system including underground entrance

More information

Additional Bulletins applicable to all F1RES LL Sprinklers Wall Wetting - Bulletin 007 Design and Installation - Bulletin 140

Additional Bulletins applicable to all F1RES LL Sprinklers Wall Wetting - Bulletin 007 Design and Installation - Bulletin 140 Bulletin 033 Rev. A Model F1 RES LL Residential s for Design Density of.05 gpm/ft 2 Bulletin 033 Rev. A Specifically Listed for use in Multipurpose Systems that serve both domestic water and fire protection.

More information

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Engine Module Page 1 of 8 Annual Sprinkler System Inspection Revised

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Engine Module Page 1 of 8 Annual Sprinkler System Inspection Revised Engine Module Page 1 of 8 ANNUAL INSPECTOR S TEST Note: In 2014 the Escondido Fire Department discontinued performing an Inspector s Test on sprinkler systems electing to inspect the system as outlined

More information

Model vkfd28b braided flexible sprinkler drops (lpcb approved)

Model vkfd28b braided flexible sprinkler drops (lpcb approved) Page 1 of 6 1. DESCRIPTION Viking Flexible Sprinkler Drops are a complete assembly intended for installation into commercial suspended ceilings with medium to heavy support tee bars as described in ASTM

More information

E x t E N d e d Co v e r ag e S p r i n k l e r s. Office Buildings Hotels Hospitals Libraries. High-Piled Storage Big-Box Retailing

E x t E N d e d Co v e r ag e S p r i n k l e r s. Office Buildings Hotels Hospitals Libraries. High-Piled Storage Big-Box Retailing Extended Coverage Sprinklers Extended Coverage Sprinklers are intended for the protection of areas larger than those specified in standard installation rules and for specific light, ordinary, or extra

More information

B. Related Sections: The following Sections contain requirements that relate to this Section.

B. Related Sections: The following Sections contain requirements that relate to this Section. SECTION 211313- FIRE-SUPPRESSION PIPING PART1 -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general prov1s1ons of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

qr fusible element sprinklers (part nos , 13959, 17535, and 17536) 3. technical data Sprinkler 42h March 14, 2013

qr fusible element sprinklers (part nos , 13959, 17535, and 17536) 3. technical data Sprinkler 42h March 14, 2013 March 14, 2013 Sprinkler 42h 1. DESCRIPTION Viking Quick Response Fusible Element Upright and Pendent Sprinklers are small thermosensitive solder link spray sprinklers available with various finishes and

More information

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions: SECTION 21 13 13 WET-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section

More information

TOOLS & MISCELLANEOUS

TOOLS & MISCELLANEOUS TOOLS & MISCELLANEOUS 01-5095 251189 Sillcock Tee Handle, For 16 Broach Splined Stem, Fits Most Outside Hose Valves. 052151010056 01-5223 251199 4 Way Stem Key, Fits Square Stems 1/4, 9/32, 5/16, & 11/32.

More information

SECTION (13900) - FIRE SUPPRESSION SYSTEMS

SECTION (13900) - FIRE SUPPRESSION SYSTEMS PART 1 GENERAL 1.01 SUMMARY SECTION 21 10 00 (13900) - FIRE SUPPRESSION SYSTEMS A. Section Includes: 1. Pipe and Fittings. 2. Sprinklers. B. Related Documents: 1. Marriott s Fire Protection and Life Safety

More information

Model F3 Dry Sprinklers

Model F3 Dry Sprinklers Features 1. The Model F3 utilizes Belleville Spring Closure Technology 2. Styles available for Model F3 Dry s: Pendent Recessed Pendent Concealed Horizontal Sidewall Recessed Horizontal Sidewall 3. 1½"

More information

NFPA Edition Update

NFPA Edition Update NFPA 13 2013 Edition Update Session Agenda A2012 Code Cycle NFPA 13 Code Development Changes to NFPA 13 (NFPA 24) What Didn t Happen Next Steps 2 A2012 Code Cycle 800+ Proposal 500+ Comments TCC Meeting

More information

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings. DIVISION 21 21 05 00 COMMON WORK RESULTS FOR FIRE SUPPRESSION PART 1 GENERAL 1.1 SECTION INCLUDES A. Pipe, fittings, sleeves, escutcheons, seals, and connections for sprinkler systems. 1.2 RELATED REQUIREMENTS

More information

What You Need to Know about Residential Sprinkler Design

What You Need to Know about Residential Sprinkler Design What You Need to Know about Residential Sprinkler Design Melisa Rodriguez, P.E., NICET IV Design Services Supervisor, Fire Safety melisa.rodriguez@uponor.com www.uponor-usa.com The Residential Sprinkler

More information

SECTION : FIRE PROTECTION SYSTEMS

SECTION : FIRE PROTECTION SYSTEMS SECTION 21 00 10: FIRE PROTECTION SYSTEMS 1. GENERAL A. This section applies to the design and performance information for fire protection and suppression systems. B. All fire protection materials and

More information

SECTION WET FIRE SPRINKLER SYSTEMS

SECTION WET FIRE SPRINKLER SYSTEMS SUNY GENESEO 211310-1 PART 1 - GENERAL 1.1 WORK INCLUDED A. Provide labor, materials, equipment and services to perform operations required for the complete installation and related Work as required in

More information

B. Section Identification for Fire Suppression Piping and Equipment.

B. Section Identification for Fire Suppression Piping and Equipment. SECTION 211300 - FIRE SUPPRESSION SPRINKLERS PART 1 GENERAL 1.1 SECTION INCLUDES A. Dry-pipe sprinkler system. B. System design, installation, and certification. C. Fire department connections. 1.2 RELATED

More information

APPENDIX H (DESIGN SUBMISSION CRITERIA)

APPENDIX H (DESIGN SUBMISSION CRITERIA) APPENDIX H (DESIGN SUBMISSION CRITERIA) FIRE ALARM SYSTEM As per ACCORD standard Part 5, section 5.7 Fire Alarm System Design to be verified by ACCORD Chief Safety Inspector. Testing of the installation

More information

CONGRATULATIONS! TABLE OF CONTENTS. Introduction. Features and Benefits. Parts Guide 4. Installation Considerations 4. Installing the Loudspeakers 6

CONGRATULATIONS! TABLE OF CONTENTS. Introduction. Features and Benefits. Parts Guide 4. Installation Considerations 4. Installing the Loudspeakers 6 ceiling mount CM7SD INSTAllation Guide DESIGNER AESTHETICS AUDIOPHILE PERFORMANCE CONGRATULATIONS! Thank you for choosing the Niles CM7SD Loudspeaker. With proper installation, use, and care, your loudspeakers

More information

MLA Architects Pierz Public Schools ISD #484 Healy High School Multi-Purpose & Choir Additions Pioneer Elementary School Class Room Addition Pierz, MN

MLA Architects Pierz Public Schools ISD #484 Healy High School Multi-Purpose & Choir Additions Pioneer Elementary School Class Room Addition Pierz, MN DIVISION 21 - FIRE SUPPRESSION (REFER TO SECTION 23 05 00 FOR BASIC FIRE SUPPRESSION REQUIREMENTS) 21 05 00 Common Work Results for Fire Suppression 21 13 13 Wet-Pipe Sprinkler Systems END OF SECTION FIRE

More information

Model F3-80 Dry K8.0 (115 metric) Standard-Response, Standard Spray Sprinklers

Model F3-80 Dry K8.0 (115 metric) Standard-Response, Standard Spray Sprinklers Bulletin 060 Rev. A Bulletin 060 Rev. A Model F3-80 Dry K8.0 (115 metric) Standard-Response, Standard Spray Sprinklers Features 1. Available in the following configurations: Pendent with standard escutcheon

More information

Top Control Dishwasher

Top Control Dishwasher INSTALLATION GUIDE Top Control Dishwasher NS-DWH2BS8/NS-DWH2SS8/NS-DWR2BS8/NS-DWR2WH8/NS-DWR2SS8 Before using your new product, please read these instructions to prevent any damage. Contents Introduction......................................................................................................

More information

MSC Guidelines for Automatic Sprinkler Systems

MSC Guidelines for Automatic Sprinkler Systems S. J. Kelly, CDR, Chief of Engineering Division References a. Title 46 CFR 56.20, 56.50 & 56.60 (Subchapter F) b. National Fire Protection Association (NFPA) 13, 1996 Edition, Installation of Sprinkler

More information

Tall Hood-type Dishwashers

Tall Hood-type Dishwashers Tall Hood-type Dishwashers Ventless Heat Recovery Option Installation Instructions Models: DH5000T, MDHHD VHR Ventless Heat Recovery LISTED Issue Date: 3.1.16 Manual P/N 115746 rev. 3765 Champion Boulevard

More information

PRICE BID. UNIT QTY Rate in Figure Rate in words Amount DESCRIPTION OF ITEM D: FIRE PROTECTION SYSTEM

PRICE BID. UNIT QTY Rate in Figure Rate in words Amount DESCRIPTION OF ITEM D: FIRE PROTECTION SYSTEM ANNEXUREIII D: FIRE PROTECTION SYSTEM SECTION ADDRESSABLE FIRE DETECTION AND ALARM SYSTEM Supply, Installation, testing and commissioning of Analogue Addressable Fire Alarm Control panel with battery backup

More information

SECTION WET-PIPE SPRINKLER SYSTEMS

SECTION WET-PIPE SPRINKLER SYSTEMS SECTION 21 13 13 WET-PIPE SPRINKLER SYSTEMS PART 1 - GENERAL 1.1 SCOPE OF WORK A. Design, installation and testing shall be in accordance with NFPA 13 except for specified exceptions. B. The demolition

More information

A. Section includes wet-pipe sprinkler system, system design, installation, and certification.

A. Section includes wet-pipe sprinkler system, system design, installation, and certification. SECTION 21 13 13 WET-PIPE SPRINKLER SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section includes wet-pipe sprinkler system, system design, installation, and certification. 1.2 REFERENCES A. General: Comply

More information

A Building Manager s Guide to Maintaining Fire Code Compliance

A Building Manager s Guide to Maintaining Fire Code Compliance A Building Manager s Guide to Maintaining Fire Code Compliance Know your role in conducting fire protection system inspections : Fire Alarm Codes and Standards Maintaining your compliance with fire code

More information

ADDENDUM NO. 3 March 19, 2018

ADDENDUM NO. 3 March 19, 2018 ADDENDUM NO. 3 March 19, 2018 PROJECT: MT. VIEW ELEMENTARY CASSIA SCHOOL DISTRICT NO 151 BURLEY, IDAHO The following addenda apply to the Project Manual and / or Drawings for this project and shall be

More information

Center for Life Safety Education

Center for Life Safety Education Center for Life Safety Education Fire Sprinklers 101 Introduction, Building Codes, and Water Supplies Reprinted with permission from NFPA 13, Installation of Sprinkler Systems, Copyright 2007, National

More information

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD INSTALLATION OF COMMERCIAL FIRE SPRINKLER SYSTEMS STANDARD #C-001 EFFECTIVE 03-25-2009 PURPOSE: To ensure that sprinkler plans submitted for review contain

More information

SECTION WET-PIPE SPRINKLER SYSTEMS

SECTION WET-PIPE SPRINKLER SYSTEMS SECTION 21 13 13 PART 1 - GENERAL 1.1 SCOPE OF WORK A. Design, installation and testing shall be in accordance with NFPA 13 except for specified exceptions. B. The design and installation of a hydraulically

More information