INSTRUCTION MANUAL. Software Revision Card 3.2 DOCUMENT SES-KS E REV. 3

Size: px
Start display at page:

Download "INSTRUCTION MANUAL. Software Revision Card 3.2 DOCUMENT SES-KS E REV. 3"

Transcription

1 2402 COMBUSTIBLE GAS CARD 2 CHANNELS 2404 TOXIC GAS CARD 2 CHANNELS 2407 OXYGEN GAS CARD 2 CHANNELS INSTRUCTION MANUAL Software Revision Card 3.2 DOCUMENT SES-KS E REV. 3

2 CHANNELS CARDS SES-ASA ENGINEERING Page 2 of INSTRUCTION MANUAL - SES-KS E Rev.3

3 SES-ASA ENGINEERING CHANNELS CARDS Information and relevant technical data contained in this manual are Copyrighted and property of SES ASA ENGINEERING S.R.L. This manual and relevant drawings cannot be used for purpose of manufacturing anything represented, nor disclosed to third parties without written approval of SES ASA ENGINEERING S.R.L. SES ASA ENGINEERING S.R.L will protect its own rights with legal means. SES ASA ENGINEERING S.R.L reserves the right to modify specifications and drawings without notice. WARRANTY SES ASA ENGINEERING S.R.L guarantees all of its products are free from manufacturing defects for a period specified in each data sheet or agreed upon with the customer. SES ASA ENGINEERING S.R.L will repair or replace at its workshop, free of charge, every instrument found to be defective during the warranty period. Technical personnel of SES ASA ENGINEERING S.R.L will determine the cause of damage. In any case the warranty is restricted to the cost of the instrument supplied by SES ASA ENGINEERING S.R.L. The customer will take the responsibility for any improper use of the instrument carried out by own or authorised personnel INSTRUCTION MANUAL - SES-KS E Rev.3 Page 3 of 32

4 CHANNELS CARDS SES-ASA ENGINEERING TABLE OF CONTENTS 1. INTRODUCTION General Block Diagram SPECIFICATIONS Specifications of Board 2402 or 2404 or Mechanical Specifications Board Rack Electrical Specifications Board Power Requirements Input Signals Auxiliary OC Output Signals ( 30Vdc@0,1A max.) per each Channel: Relay Output Signals Analog Input Accuracy: Operating Conditions INSTALLATION Handling and Shipping Installation Installation of Sensors with Field Transmitter OPERATIVE INSTRUCTIONS Operation Connector Connections to the Field Connection to a Sensor with 4-20 ma Transmitter or Smart Sensor Setting and Operation of Auxiliary Outputs Fail to Safe Operation of Alarm/Warning Auxiliary Outputs, in Flashing or Continuous mode Front Keyboard Procedures Executable from the Front Panel Flow Diagram of Front Keyboard Operating Modes Use of Hand-Held Monitor Test Unit Channel status check Modification of Warning threshold Modification of Alarm threshold Analogue Inputs Test Board Configuration Switch Setting Table Jumper Setting Table Selection Card Type 2402 or 2404 or Selection input Type Typical Connections (3-wires sensor) Typical Connections (4-wires sensor) MAINTENANCE General Storage Self-Calibration DIAGNOSTICS Board Diagnostics Diagnostics of Power Supplies and Microprocessor Diagnostics of I/O Section Interpretation Codes Error Codes Troubleshooting Spare Parts CARD LAYOUT Page 4 of INSTRUCTION MANUAL - SES-KS E Rev.3

5 SES-ASA ENGINEERING CHANNELS CARDS 1. INTRODUCTION 1.1. General Control unit 2402 or 2404 or 2407, a component of series F&G/ESD 2000, is designed for detection of toxic or combustible gas and vapour in air, such as: LPG (Butane / Propane), Methane, Hydrogen, Acetylene, Ethylene, Toluene, Carbon Monoxide, Ammonia, Hydrogen Sulphide, Oxygen, etc.... Control unit 2402 or 2404 or 2407 interfaces directly with transmitters-sensors with 0-22 ma current output or with Smart Sensors in any configuration, including Intrinsically Safe configuration. This exclusive feature allows the user to connect a wide variety of two, three or 4-wire transmitters available on the market. Using a single chip microprocessor, present in the entire 2400 family, gives more reliability and accuracy. The microprocessor allows the setting of alarm set points through software commands, instead of using potentiometers. A two-digit display indicates the detected combustible gas LEL (lower explosive limit) on a 00-99% LEL scale or toxic gas ppm (part per million) on a ppm scale, or oxygen gas on a 00-25% Volume scale, and any error codes. The indicated concentration becomes flashing for LEL/ppm values over 99. The operating conditions (Alarm, Warning, Ready, Fault) can also be monitored through double LED indicators on front panel. The control unit sends both the analogue values and the status of the two input channels to the CPU (CPU Facility 2401) through a high-speed redundant RS 485 serial port. A complete self diagnosis, made possible by the microprocessor, allows supervision and control of board components functionality, correct operation of internal power supplies triggering, and in the case of failure activates the relevant malfunction outputs or Watchdogs. To increase the operational safety of the control unit, the logical section (including microprocessor, serial interfaces and internal power supplies) is galvanically isolated from the input/output section from/to the field by opto-isolators. The control unit makes available, on the connector, open collector outputs for warning, alarm and failure, configurable through DIP switches for FLASHING and NON-FLASHING modes. The board is fitted with a 32-pin DIN I/O connector INSTRUCTION MANUAL - SES-KS E Rev.3 Page 5 of 32

6 CHANNELS CARDS SES-ASA ENGINEERING 1.2. Block Diagram Page 6 of INSTRUCTION MANUAL - SES-KS E Rev.3

7 SES-ASA ENGINEERING CHANNELS CARDS 2. SPECIFICATIONS 2.1. Specifications of Board 2402 or 2404 or 2407 Application: Measure Span 2402: Measure Span 2404: Measure Span 2407: N. of Channels: Operating Environment: Warranty: Detection of Combustible, Toxic or Oxygen gases (together with a sensor with 4-20 ma transmitter or Smart Sensor) 0-100% LEL (lower explosive limit) 0-20, 0-50 or ppm (part per million) 0-25% Volume (depletion of Oxygen in air) 2 analogue inputs 0 22mA Safe area 2 years of uninterrupted operation Mechanical Specifications Board Size: Double euro elongated 6U 19 Weight: Height: Length: Front Width: 440 g 233 mm 220 mm 5TE Rack Size: Weight: Standard 19 6U 2600 g Width: 19 Height: Depth: 266 mm 283 mm INSTRUCTION MANUAL - SES-KS E Rev.3 Page 7 of 32

8 CHANNELS CARDS SES-ASA ENGINEERING 2.3. Electrical Specifications Power Supply: 24Vdc (nominal), 20 to 30Vdc Fuse: 24Vdc ISO line: 500mA, Retard 24Vdc I/O line: 500mA, Retard Board Power Requirements Internal consumption: 24Vdc ISO line: Quiescent : 130mA Alarm : 140mA Input Signals Dual channel analogue signal 0 22 ma (single point) 24Vdc I/O line: Quiescent/Alarm: 50mA (this value does not include consumption of the sensor with transmitter connected to the board.) Auxiliary OC Output Signals ( 30Vdc@0,1A max.) per each Channel: - Warning - Alarm - Fault - Fail to Safe for Alarm communication failure or Calibration (selection by DP8-SW2) Relay Output Signals Common and N.O. contact for Watchdog signal with capacity for resistive loads: - 250Vac - 125Vdc - 30Vdc Note: the relay is normally energised Analog Input Accuracy: 2% FDS on input 0 to 22mA Page 8 of INSTRUCTION MANUAL - SES-KS E Rev.3

9 SES-ASA ENGINEERING CHANNELS CARDS 2.4. Operating Conditions Operating Temperature: Storage Temperature: Environment Humidity: 0 C to + 70 C (32 to +158 F) -40 to + 85 C (-40 to +185 F) 0% to 95% not condensing. 2.5 Front Panel Indications For each channel: Common: Two digits displays (7 segments) for L.E.L. and/or error codes display Redundant LED (red) for Alarm Redundant LED (red) for Warning Redundant LED (yellow) for Fault Redundant LED (green) for correct operation Ready Redundant LED (red) for serial line transmission (TX) Redundant LED (red) for serial line reception (RX) Redundant LED (yellow) for Watchdog (WD) active INSTRUCTION MANUAL - SES-KS E Rev.3 Page 9 of 32

10 CHANNELS CARDS SES-ASA ENGINEERING 3. INSTALLATION 3.1. Handling and Shipping Every piece of equipment supplied by SES ASA ENGINEERING S.R.L is packed in order to prevent physical damage. Carefully check the contents of any package when received. Any noticed inconsistency should be communicated to SES ASA ENGINEERING S.R.L within ten days from material reception. SES ASA ENGINEERING S.R.L will not be liable for any damage if this communication is not forwarded within the indicated terms. Any claims for damage will be communicated in writing form also to the carrier. Any written communication must include product model and serial number Installation Although 2400 modules are built to be free from electromagnetic interference s, they should be installed in a place away from EMR sources such as motors, RF equipment, etc. Connection cables must be totally shielded and have a drain wire. The shield should be connected only to the safety panel end. If the modules are installed in enclosed places (cabinets), the maximum heat sink in accordance with available space should be considered, in order to avoid excessive overheating. A suitable ventilation system may have to be considered. SES ASA ENGINEERING S.R.L is at your complete disposal in supplying qualified experienced staff with the knowledge to review the plant feasibility Installation of Sensors with Field Transmitter The installation of the instruments in hazardous areas should be carried out in accordance with local safety regulations, technical and functional specifications of used equipment, making reference to the technical documentation for installation. Page 10 of INSTRUCTION MANUAL - SES-KS E Rev.3

11 SES-ASA ENGINEERING CHANNELS CARDS 4. OPERATIVE INSTRUCTIONS 4.1. Operation At start up of board 2402, 2404 or 2407 the microprocessor inhibits outputs (Open Collectors) and displays on the front panel so that the initial undetermined logical status s does not force any activation or signal in the system. The microprocessor reads the configuration status of operating mode Dip-Switches, namely: - Card address - Activation mode (continuous or flashing) of Open Collector outputs - Possible use of sensors with transmitter with self calibration function - Set up of communication speed on serial line. To set these operating modes, please refer to section 4.5. The microprocessor verifies the data set up by the Dip-Switches and the card is configured with new parameters. After executing these preliminary checks, the detection system enters a waiting status of about 70 seconds or 140 seconds, the Ready LED of each channel starts flashing and on the display appears the Su message (System in Start-up mode). This wait is necessary to permit the field analogue line stabilisation. Then the card starts the operating mode, and the card display shows the detected gas concentration in % of L.E.L. (Lower Explosive Limit) or in ppm (part per million) or in % Volume (Oxygen) of any system or error codes (see 6.2). Open Collector outputs, front panel LED s and watchdog relay are enabled INSTRUCTION MANUAL - SES-KS E Rev.3 Page 11 of 32

12 CHANNELS CARDS SES-ASA ENGINEERING Connector Connections to the Field Note: the watchdog relay is normally energised; so, during normal operation, this contact will be closed (open in case of Fault) Connection to a Sensor with 4-20 ma Transmitter or Smart Sensor The board is designed to be directly connected to both 3-wire and 4-wire 4-20 ma transmitters. The different types of transmitters and relevant connections are indicated in section Typical Connections. Page 12 of INSTRUCTION MANUAL - SES-KS E Rev.3

13 SES-ASA ENGINEERING CHANNELS CARDS 4.2. Setting and Operation of Auxiliary Outputs The card 2402 or 2404 or 2407 has eight Open Collector outputs available on the connector: CH1 OC1 = Alarm OC2 = Warning OC3 = Fault OC4 = Calibration/Fail to Safe CH2 OC5 = Alarm OC6 = Warning OC7 = Fault OC8 = Calibration/Fail to Safe The calibration output (O.C.) is activated by a signal from the Smart Sensor (if this function is available) for automatic calibration Fail to Safe In case of communication failure between Gas input card and CPU, logic micro operates the FAIL-TO-SAFE condition directly by local micro firmware output. In case of Alarm, input card transmit the Alarm status to 2401-CPU Facility Card, but if the input card don t receive the call back signal, that confirm the successful operation, it will activate the O.C. dedicated to Fail to Safe (Alarm communication failure). For the Selection of Fail-to-Safe mode see paragraph Operation of Alarm/Warning Auxiliary Outputs, in Flashing or Continuous mode If SW2-6 is set to ON, in case of Warning or Alarm, O.C. outputs will be activated flashing. Alarm, Warning signals and front panel LED s will set to continuous pressing ACK button on the CPU Facility. Their deactivation is conditioned to the removal of the Alarm cause, or to pressing RESET the button on the Facility 2401, if is set the ISA-2C sequence. If SW2-6 is set to OFF, in case of Warning or Alarm, O.C. outputs will be activated continuously (to deactivate act as described above) INSTRUCTION MANUAL - SES-KS E Rev.3 Page 13 of 32

14 CHANNELS CARDS SES-ASA ENGINEERING 4.3. Front Keyboard 2402 %L.E.L p p m 2407 % O 2 7 Segment Each Display for Value Reading on CH1 ALARM ALARM ALARM ALARM Indication (double red LED) - CH1 Alarm WARN WARN WARN WARNING Indication (double red LED) - CH1 Warning READY FAULT %L.E.L. READY FAULT p p m READY FAULT % O 2 READY Indication (double green LED) - CH1 Ready FAULT Indication (double yellow LED) - CH1 Fault 7 Segment Each Display for Value Reading on CH2 ALARM ALARM ALARM ALARM Indication (double red LED) - CH2 Alarm WARN WARN WARN WARNING Indication (double red LED) - CH2 Warning READY FAULT READY FAULT READY FAULT READY Indication (double green LED) - CH2 Ready FAULT Indication (double yellow LED) - CH2 Fault TX TX TX TX Indication (double red LED) of Serial Line Transmission RX WD RX WD RX WD RX Indication (double red LED) of Serial Line Receive WD Indication (double yellow LED) of WatchDog Control (Instrument Ready) SEL INH SEL INH SEL INH FRONT BUTTONS SET TEST SET TEST SET TEST See paragraf Procedures executable from the front panel H H H H H H 25 Pins, DB Connector, for Hand Held Monitor M M M Page 14 of INSTRUCTION MANUAL - SES-KS E Rev.3

15 SES-ASA ENGINEERING CHANNELS CARDS Procedures Executable from the Front Panel These procedures can be activated through the front panel pushbuttons: 1. Display of Warning and Alarm set points. 2. Channel shutdown (permanent inhibition) 3. Test. Display of warning and alarm set points a) Press SEL button: the first channel display will show SE (Selection) and the READY LED will flash. b) Press SET button: the WARNING LED will start flashing and the display will still indicate the Warning threshold value. c) Press SET again: WARNING LED will turn off and ALARM LED will flash. The display will indicate the Alarm threshold value. d) Press SEL: the first channel READY LED will change to continuous and the relevant display will show again the value read from LEL. The second channel READY LED will flash and the relevant display, will show code SE (Selected). e) Repeat action b) and c) to see the Alarm set points. f) Press SEL: the second channel READY LED will change to continuous and the relevant display will show again the value read from LEL. Note: If the signal procedure for a channel is not completed, about 20 seconds after the last button has been pressed the system automatically switches to normal operating mode. Channel shutdown (permanent inhibition) a) Press SEL button: once to select channel 1, twice for channel 2. b) After selecting the desired channel press INH: the display will deactivate while the relevant READY LED will blink, confirming the channel has been inhibited. c) Press SEL to deselect the channel; READY will turn off too. Note: the signal Card inhibition will remain active till the card is powered on. After a power shut-down, the channels will return active at system powering on INSTRUCTION MANUAL - SES-KS E Rev.3 Page 15 of 32

16 CHANNELS CARDS SES-ASA ENGINEERING Restoring of Inhibited Channel Test a) Select the desired channel pressing SEL. b) The relevant READY LED will blink. c) Press INH: the display will indicate SE (Selection) d) Press SEL: the display will indicate the LEL value of the restored channel. Pressing TEST button, ALARM, WARNING, READY and FAULT LED s of both channels flash for 5 seconds to check they are working correctly. Also the two digits display flashes with all segments. The microprocessor also carries out a self test to check operation of each channel directly forcing the analogue input to a pre-set value, checking its correlation and the amount of any error, then verifying the analogue and digital circuit of each input channel. Any malfunction detected is signalled to the CPU Facility that will display or print out the detected malfunction. Page 16 of INSTRUCTION MANUAL - SES-KS E Rev.3

17 SES-ASA ENGINEERING CHANNELS CARDS Flow Diagram of Front Keyboard Operating Modes Cycle for Display of Warning and Alarm Thresholds INSTRUCTION MANUAL - SES-KS E Rev.3 Page 17 of 32

18 CHANNELS CARDS SES-ASA ENGINEERING Cycle for Channel Inhibition Page 18 of INSTRUCTION MANUAL - SES-KS E Rev.3

19 SES-ASA ENGINEERING CHANNELS CARDS 4.4. Use of Hand-Held Monitor Test Unit 2490 The H.H.M unit allows access to some special operating modes not accessible from the board front controls. This device, powered and controlled by the board, is automatically configured when the 25-pin connector is inserted in the special receptacle on the front panel. After connecting the Hand-Held Monitor the initialisation message is displayed: SES-ASA 2402 r 3.2 (resident software revision number) Card Address 000 (board addressing number from 0 to 254) HAND HELD MONITOR INFO SETP RAMP and these functions are available: Card address check-test Latch/No Latch status check and channel set-point check Modification of Warning threshold Modification of Alarm threshold Analogue inputs test NOTE: If there is any Warning or any Alarm, the display will show this message: SES-ASA 2402 r3.2 Card Address 000 HAND HELD MONITOR -KEYS NOT AVAILABLE- This message informs the operator that the H.H.M. will not function, until the status of the channels will return to the Ready mode Channel status check 1. From the main menu press function key F1 (INFO). The display will show this message: WRN LAT ALM LAT 10 no 15 no CH1 20 yes 25 yes CH2 %LEL %LEL This screen shows the set points of the two input channels, reporting their LATCH/NO LATCH status. 2. Press Enter to return to the main menu. The menu will automatically return to main menu after 10 of inactivity INSTRUCTION MANUAL - SES-KS E Rev.3 Page 19 of 32

20 CHANNELS CARDS SES-ASA ENGINEERING Modification of Warning threshold 1. From the main menu press function key F2 (SETP). The display will show this message: SES-ASA 2402 r3.2 Card Address 000 Hand Held Monitor WARN ALAR 2. From this menu press function key F1 (WARN). The display will show this message: SES-ASA 2402 WARNING CH1_10 %LEL WARNING CH2 20 %LEL CH1 CH2 The underscore symbol _ will be on the row of the selected channel Values 10 and 20 (e.g.) are the set threshold points. 2. Select the wanted channel pressing F1 (CH1) and F2 (CH2) buttons. The _ symbol will be on the row of the selected channel. 3. Modify the threshold value by pressing arrows and. 4. Press Enter to return to the previous menu. Note: If the Warning threshold is higher than the Alarm threshold the display will show this message: INPUT VALUE ERROR : DATA NOT CHANGED The card will ignore the new value and will maintain the old one. This message will last for 3 sec, then the display will automatically return to the main menu. Page 20 of INSTRUCTION MANUAL - SES-KS E Rev.3

21 SES-ASA ENGINEERING CHANNELS CARDS Modification of Alarm threshold 1. From the main menu press function key F2 (SETP). The display will show this message: SES-ASA 2402 r3.2 Card Address 000 Hand Held Monitor WARN ALAR 2. From this menu press function key F2 (ALAR). The display will show this message: SES-ASA 2402 ALARM CH1_15 %LEL ALARM CH2 25 %LEL CH1 CH2 The underscore symbol _ will be on the row of the selected channel Values 15 and 25 (e.g.) are the set threshold points. 3. Select the wanted channel by pressing F1 (CH1) and F2 (CH2) buttons. The _ symbol will be on the row of the selected channel. 4. Modify the threshold value by pressing arrows and. 5. Press Enter to return to the previous menu. Note: If the Alarm threshold is lower than the Warning threshold the display will show this message: INPUT VALUE ERROR : DATA NOT CHANGED The card will ignore the new value and will maintain the old one. This message will last for 3, then the display will automatically return to the main menu INSTRUCTION MANUAL - SES-KS E Rev.3 Page 21 of 32

22 CHANNELS CARDS SES-ASA ENGINEERING Analogue Inputs Test This function simulates an input signal variation in order to verify the system operation, without interacting with the field sensor. Attention: During this test, the field signal will not be read, because the input circuit is under the H.H.M. influence. 1. From the main menu press function key F4. The display will show this message: SES-ASA 2402 TEST INPUT 1_04mA TEST INPUT 2 10mA CH1 CH2 The underscore symbol _ will be on the row of the selected channel. Values 04mA and 10mA (e.g.) are the analogue value. 2. Select the wanted channel by pressing F1 (CH1) and F2 (CH2) buttons. The _ symbol will be on the row of the selected channel. 3. Modify the analogue input current by pressing arrows and. The display will show the changes 4. Press Enter to return to the previous menu. Card 2402 or 2404 or 2407 will return to the operative condition, ignoring any previous simulated input. Page 22 of INSTRUCTION MANUAL - SES-KS E Rev.3

23 SES-ASA ENGINEERING CHANNELS CARDS 4.5. Board Configuration Switch Setting Table SW1 Board address setting (0-254) DP1 Address with weight 1 DP2 Address with weight 2 DP3 Address with weight 4 DP4 Address with weight 8 DP5 Address with weight 16 DP6 Address with weight 32 DP7 Address with weight 64 DP8 Address with weight 128 Note: it is not possible to configure more than one board with the same address SW2 DP1 See Point DP2 See Point DP3 ON: Insert decimal point to display OFF: Disable decimal point to display DP4 ON: channel 2 disabled OFF: channel 2 enabled DP5 See Point DP6 ON: Open Collector outputs for Warning and OFF: Open Collector outputs for Warning and Alarm Alarm in FLASHING mode in STEADY mode DP7 See Point DP8 ON: (O.C.4-CH1) (O.C.8-CH2) = FAIL TO SAFE OFF: (O.C.4-CH1) (O.C.8-CH2) = CALIBRATION Jumper Setting Table The card 2402 or 2404 or 2407 has the following jumpers: - JP1:...used to activate RESET signal - JP2:...used to power the serial bus JP1 Close: forced RESET - Open: non forced RESET JP2 Close: the board feeds the amplification circuit of the serial bus 2480 Open: the board does not feed the amplification circuit of the serial bus 2480 Factory setting must not be altered Selection Card Type 2402 or 2404 or 2407 SW2 DP1 DP2 DP5 ALL OFF DP1 ON DP2 ON DP1 & DP2 ON DP5 ON 2402 Measure Full Scale 100 % L.E.L 2404 Measure Full Scale 100 ppm 2404 Measure Full Scale 50 ppm 2404 Measure Full Scale 20 ppm 2407 Measure Full Scale 25 % Volume Selection input Type SW2 DP7 ON (STAR-UP 140 WAIT TIME) SW2 DP7 OFF (STAR-UP 70 WAIT TIME) INPUT CURRENT ma STATUS CARD MESSAGE ON DISPLAY INPUT CURRENT ma STATUS CARD MESSAGE ON DISPLAY > 20,1 Over Range or > 20,1 Over Range or 3,0 20 Measure Range ,4 20 Measure Range ,7 2,9 Dirty Optical d.o. 3,1 3,3 Error S-600 E5 1,4 1,6 Calibration CA 2,1 3,0 Fault -5 E5 < 1,4 Fault E5 1,4 2,0 Calibration CA < 1,4 Fault E5 Is under working a version with dirty optical and calibration values, configurable by software P.S.2400, not available with this firmware version INSTRUCTION MANUAL - SES-KS E Rev.3 Page 23 of 32

24 CHANNELS CARDS SES-ASA ENGINEERING 4.6. Typical Connections (3-wires sensor) Page 24 of INSTRUCTION MANUAL - SES-KS E Rev.3

25 SES-ASA ENGINEERING CHANNELS CARDS 4.7. Typical Connections (4-wires sensor) INSTRUCTION MANUAL - SES-KS E Rev.3 Page 25 of 32

26 CHANNELS CARDS SES-ASA ENGINEERING 5. MAINTENANCE 5.1. General Module 2402 or 2404 or 2407, part of system F&G/ESD 2000 system should be installed following the specifications supplied, to ensure correct operation. The entire system (sensors and electronics) should be tested at least once a year. Checking of module 2402 or 2404 or 2407 will include these steps: a) Check that cables and connections are integral and in good condition. b) Check that the system response is fully in accordance with the cause-effect table Storage a) The electronic modules should be stored in a dry room and at temperatures within the values indicated in section 2. b) If the modules are to be transported or stored for a long time, they should be contained in antistatic envelopes and packed with protective material Self-Calibration This function is available only if the transmitter has this feature. Set Dip 7 of SW 2 ON and set Dip 8 of SW2 OFF, accordingly with the calibration output current coming from the transmitter during auto calibration routine. When auto calibration is activated, the transmitter will send to the card a typical current. This signal will start the calibration on the card. On the display (relative to the calibrated channel) will appear the CA message. Follow the calibration instruction described on the manual of the transmitter. Page 26 of INSTRUCTION MANUAL - SES-KS E Rev.3

27 SES-ASA ENGINEERING CHANNELS CARDS 6. DIAGNOSTICS Board 2402 or 2404 or 2407, designed for management of 2 analogue input channels, gives indication of each channel status through the corresponding LED s placed on the front panel. If Fault LED s do not activate, it is necessary to accurately investigate the board circuitry to detect the exact nature of this Fault Board Diagnostics Board 2402 or 2404 or 2407 has two logically separated circuits: one is aimed to operating design function, the other verifies the circuitry so that it is always possible to detect and recognise any Fault. The diagnostics is carried out on two levels: - power supply and operation of the microprocessor - test of input circuit section Diagnostics of Power Supplies and Microprocessor Board 2402 or 2404 or 2407, powered by two 24Vdc sources named ISO and I/O, is provided with three DC/DC converters dedicated to power supply of all of its sections: - logical section (ISO) - I/O section (I/O) The following diagram shows the circuit used to diagnose the power supply and microprocessor functions together with the Watchdog circuit INSTRUCTION MANUAL - SES-KS E Rev.3 Page 27 of 32

28 CHANNELS CARDS SES-ASA ENGINEERING Diagnostics of I/O Section The I/O section of board 2402 or 2404 or 2407 is continuously tested from the input terminal down to the microprocessor. The test circuit is shown below: 6.2. Interpretation Codes According to the function executed by the card, the display will show these related codes: CA Channel calibration Su The card is waiting for the analogue input signal stabilisation 99 Flashing. Analogue input signal between 20 and 22mA Or Over range. Analogue input signal more than 22mA d.o. Dirty Optical. Visible when DP7 of SW2 is ON, if used Infrared Gas detectors Error Codes When the card detects the presence of any error the channel display will show the following messages: E1 E2 E3 E5 ISO power supply failure 24Vdc I/O power supply failure Logical section failure Analogue input signal less than 1mA Page 28 of INSTRUCTION MANUAL - SES-KS E Rev.3

29 SES-ASA ENGINEERING CHANNELS CARDS 6.3. Troubleshooting This information is given as a guide to detect some of the most common operating problems. In case of failure, personnel authorised by SES ASA ENGINEERING S.R.L must carry out any repair. Any repair or tampering made by unauthorized personnel will invalidate the warranty. FAULT: Low feed voltage in I/O section. Possible Cause: Unsuitable, undersized or defective power supply. Too high resistance of supply line. Remedy: Give a power supply suitable to the system power requirements. Use power cables with suitable cross sectional area. FAULT: Low analogue input signal (from transmitter). Possible Cause: Connection cable interrupted or high wire resistance. Remedy: Replace the cable. Verify transmitter wiring with instructions listed at ch. 4. Possible Cause: Calibration not correct. Remedy: Calibrate again the sensor/transmitter. Possible Cause: Dip-Switches for gas or sensor selection not selected correctly. Remedy: Re-configure Dip-Switches. Verify Switch setting with instruction described at chapter 4. FAULT: High analogue input signal (from transmitter). Possible Cause: Dip-Switches for gas or sensor selection not selected correctly. Remedy: Re-configure Dip-Switches. Verify Switches setting with instruction described at chapter INSTRUCTION MANUAL - SES-KS E Rev.3 Page 29 of 32

30 CHANNELS CARDS SES-ASA ENGINEERING FAULT: Pushbuttons on front panel not operating. Possible Cause: The front panel buttons can be used only if previously enabled by the CPU Facility through relative command. Remedy: Enable the buttons through the Facility 2401 front panel buttons FAULT: Unable to calibrate correctly the sensor. Possible Cause: Sensor or transmitter not corresponding to the appropriate characteristics. Not correct Calibration gas. Remedy: Replace the sensor or/and the transmitter. Use the appropriate calibration gas kit. FAULT: Board not operating (Watchdog LED on front panel off). Possible Cause: Fault in electronics (microprocessor, internal power supply, etc.). Remedy: Check the protection fuses and/or replace the board. The indications and explanations above should be considered as a suggestion in case of failure or malfunction. Whenever the problem cannot be solved even after following the above instructions, or it is not listed, please contact SES ASA ENGINEERING S.R.L or their representative. Page 30 of INSTRUCTION MANUAL - SES-KS E Rev.3

31 SES-ASA ENGINEERING CHANNELS CARDS 6.4. Spare Parts COMPONENT serial code - Complete card Complete card Complete card Front panel Front panel Front panel Programmed M38002 microprocessor 2402/2404/ A/D converter 574 contact SES-ASA - L602 integrated circuit contact SES-ASA - DS2Y relay HARTING connector mod JP 122 isolated amplifier (Burr Brown) Contact SES-ASA - TLP 521/2 opto-isolator INSTRUCTION MANUAL - SES-KS E Rev.3 Page 31 of 32

32 CHANNELS CARDS SES-ASA ENGINEERING 7. CARD LAYOUT Page 32 of INSTRUCTION MANUAL - SES-KS E Rev.3

33 SES ASA ENGINEERING S.R.L Via Carolina Romani 8/ BRESSO (MI) ITALY Declare Under Proper Responsibility That PRODUCT : 2400 SERIES MODEL : 2402 Combustible Gas Card 2404 Toxic Gas Card 2407 Oxygen Gas Card Is In Accordance With Following Directives: EMC 89/336CEE e 92/31/CEE EN CEI110-6 EN EN EN IEC IEC IEC801-2 e IEC In Legal Representation of Manufacturer SES ASA ENGINEERING S.R.L

BX444-Mc Gas Detector

BX444-Mc Gas Detector Installation and User Guide Rev.01. BX444-Mc Gas Detector Application Duomo is recognised within the gas industry for providing a comprehensive range of low cost, high reliability gas detection for many

More information

Pioneer-R16 Gas Monitor Operator s Manual

Pioneer-R16 Gas Monitor Operator s Manual Pioneer-R16 Gas Monitor Operator s Manual Edition 7/2/97 RKI INSTRUMENTS, INC RKI Instruments, Inc. 33248 Central Ave, Union City, CA 94587 (510) 441-5656 Chapter 1: Description About the Pioneer-R16 Gas

More information

GS100M Gas Detection Controller

GS100M Gas Detection Controller GS100M Gas Detection Controller GS100M 1 Zone Gas Detection Controller 1 Zone / Sensor Conventional Positive Safety IP44 EN61010-1 EN50270 FEATURES Single Zone Protection Positive Safety Option Detection

More information

ACCURATE ELECTRONICS INC

ACCURATE ELECTRONICS INC ACCURATE ELECTRONICS INC Page 1 of 7 Model 108078 2 Sept 09 WWW.ACCURATE.ORG PO BOX 1654 97075-1654 8687 SW Hall Blvd 97008 BEAVERTON OR USA 503.641.0118 FAX 503.646.3903 Practice Section 108078 Rev A

More information

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6 Digital Gas Transmitters with Auxiliary s & Control Specifications subject to change without notice. USA 181011 Page 1 of 5 DESCRIPTION Digital RS-485 communicating, addressable toxic and combustible gas

More information

MODEL QTS-1800 SERIES WALL MOUNT DIGITAL AND ANALOG TRANSMITTER/SENSOR

MODEL QTS-1800 SERIES WALL MOUNT DIGITAL AND ANALOG TRANSMITTER/SENSOR MODEL QTS-1800 SERIES WALL MOUNT DIGITAL AND ANALOG TRANSMITTER/SENSOR INSTALLATION OPERATION AND MAINTENANCE MANUAL QUATROSENSE ENVIRONMENTAL LTD. 5935 OTTAWA STREET, PO BOX 749 RICHMOND, ONTARIO CANADA

More information

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX Page 1 of 10 Model 10807800 January 2014 ACCURATE ELECTRONICS INC PO BOX 1654 97075-1654 8687 SW HALL BLVD 97008 BEAVERTON OR USA 503.641.0118 FAX 503.646.3903 WWW.ACCURATE.ORG Practice Section 10807800

More information

MODEL 5100 VOTING LOGIC MODULE

MODEL 5100 VOTING LOGIC MODULE DESCRIPTION DESCRIPTION The SST Model 5100 Multi-Input Voting Logic Module is used to monitor the status of up to 14 different points in a hazard zone, and report when a selectable number of these points

More information

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head 4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head NET DRAFT version 2.1-2008 Pag. 1 4-20mA Cyber - DRAFT version 2.1-2008 Pag.

More information

Warranty Registration

Warranty Registration WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free from defects in workmanship and materials for a period

More information

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification 1.0 This specification details the attributes and operating characteristics of the MSA Ultima X Series sensors/transmitters.

More information

GTA 4100R. Dual Processor, Dual Channel Controller Card. Part Number R. Manual Revision v6.30 (updated 10 November 2009)

GTA 4100R. Dual Processor, Dual Channel Controller Card. Part Number R. Manual Revision v6.30 (updated 10 November 2009) GTA 4100R Dual Processor, Dual Channel Controller Card Part Number 73 4100R Manual Revision v6.30 (updated 10 November 2009) Table of Contents 1 Introduction...6 1.1 Features...6 1.2 Front Panel Layout...7

More information

RS 0021 DIGITAL GAS DETECTION CONTROL UNIT FOR SENSORS WITH S-BUS PROTOCOL. USER MANUAL Read carefully before use

RS 0021 DIGITAL GAS DETECTION CONTROL UNIT FOR SENSORS WITH S-BUS PROTOCOL. USER MANUAL Read carefully before use RS 0021 DIGITAL GAS DETECTION CONTROL UNIT FOR SENSORS WITH S-BUS PROTOCOL USER MANUAL Read carefully before use GENERAL INFORMATION This device is a gas control unit with RS485 serial communication, based

More information

SCAN200E USER S MANUAL

SCAN200E USER S MANUAL SCAN200E USER S MANUAL Code No. 2071 1052 rev. 1.4 Code No. 2071 1052 Rev. 1.4 Page 2/16 SCAN200E User s Manual Foreword This manual is for SCAN200E Controller running software version 2.03 or later. We

More information

ECO N DATE DESCRIPTION OF CHANGE CHG

ECO N DATE DESCRIPTION OF CHANGE CHG Model Number: M21E-24-DIN Description: The product is a loop powered device which controls an unsupervised dual pole output channel suitable to manage 24VAC loads. The M21E-24-DIN is micro-controller operated,

More information

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro A d e v i h c r D c o n e m u WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free from defects in workmanship

More information

SEC 2000 Millenium Infrared Gas Detector

SEC 2000 Millenium Infrared Gas Detector SEC 2000 Millenium Infrared Gas Detector Instruction and Operation Manual Sensor Electronics Corporation 5500 Lincoln Drive Minneapolis, Minnesota 55436 USA (952) 938-9486 Fax (952) 938-9617 Email: sales@sensorelectronic.com

More information

INSTRUCTION MANUAL ENGLISH. Card Revision: Software Card Revision: Hardware 1.00 DOCUMENT SES-KS-1801MR3HE-E REV. 3

INSTRUCTION MANUAL ENGLISH. Card Revision: Software Card Revision: Hardware 1.00 DOCUMENT SES-KS-1801MR3HE-E REV. 3 DETECTION CARD With 2 Supervised Loop INSTRUCTION MANUAL ENGLISH Card Revision: Software 1.10-1.11 Card Revision: Hardware 1.00 DOCUMENT SES-KS-1801MR3HE-E REV. 3 INSTRUCTIONS MANUAL The information and

More information

RTD TEMPERATURE SENSING SYSTEM

RTD TEMPERATURE SENSING SYSTEM General Overview RTD TEMPERATURE SENSING SYSTEM The Prime Technology RTD Temperature System 9219-00-0002 is a three-channel temperature measuring system that utilizes two RTD Temperature Sensor inputs

More information

BX444-M Gas Detector. Features. Application. Operation

BX444-M Gas Detector. Features. Application. Operation BX-M Gas Detector Application Duomo is recognised within the gas industry for providing a comprehensive range of low cost, high reliability gas detection for many applications. We have installed and commissioned

More information

Controllers. Instruction Manual WARNING

Controllers. Instruction Manual WARNING Controllers Instruction Manual WARNING THIS MANUAL MUST BE CAREFULLY READ BY ALL INDIVIDUALS WHO HAVE OR WILL HAVE THE RESPONSIBILITY FOR INSTALLING, USING OR SERVICING THIS PRODUCT. Like any piece of

More information

Meridian wiredhart. HART Field Device Specification Goldmine Rd. Monroe, NC USA

Meridian wiredhart. HART Field Device Specification Goldmine Rd. Monroe, NC USA HART Field Device Specification Meridian wiredhart 4320 Goldmine Rd. Monroe, NC 28110 USA HART is a registered trademark of the HART Communication Foundation TABLE OF CONTENTS 1. Introduction...5 1.1 Scope...5

More information

SCHMIDT LED Measured Value Display MD Instructions for Use

SCHMIDT LED Measured Value Display MD Instructions for Use SCHMIDT LED Measured Value Display MD 10.010 Instructions for Use Table of Contents 1 Important Information... 3 2 Application range... 4 3 Mounting instructions... 4 4 Electrical connection... 6 5 Signalizations...

More information

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR SAFETY MANUAL SIL 2 Certified Model FP-700 Combustible Hydrocarbon Gas Sensor Version 2.0 1 SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR This manual addresses the specific requirements and recommendations

More information

SIRA srl. Installation and user manual. Consolle/Digit Remote LCD Annunciator. Remote LCD Annunciator INSTALLATION & USERS MANUAL.

SIRA srl. Installation and user manual. Consolle/Digit Remote LCD Annunciator. Remote LCD Annunciator INSTALLATION & USERS MANUAL. Page 1 / 15 Installation and user manual Page 2 / 15 Sira s.r.l. reserves the right to make modifications to this manual and the product described herein without prior notice. Sira s.r.l. shall not be

More information

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08 GasScanner 4C Four Channel Monitor Operator s Manual MINT-0280-XX Rev. A 02/25/08 Product Warranty Matheson Tri-Gas., warrants gas alarm equipment sold by us to be free from defects in materials, workmanship,

More information

Instruction Manual WARNING

Instruction Manual WARNING Controllers Instruction Manual WARNING THIS MANAUL MUST BE CAREFULLY READ BY ALL INDIVIDUALS WHO HAVE OR WILL HAVE THE RESPONSIBILITY FOR INSTALLING, USING OR SERVICING THIS PRODUCT. Like any piece of

More information

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460) Operating Manual TS400 Test Station for Microtector II Series (G450/G460) GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 44143 DORTMUND, Germany TEL. +49 / (0)2 31 / 5 64 00 0 FAX +49 / (0)2 31 /

More information

GS100M Gas Detector. Features. Application. Operation

GS100M Gas Detector. Features. Application. Operation GS00M Gas Detector Microprocessor control Wall or panel mounted zone protection 4-20mA signal input Measuring range 0-20% L.E.L. / 0-300ppm P44 protective rating EN5094 for explosive gases EN5029 for toxic

More information

Instrumentation Products and Applications

Instrumentation Products and Applications 1 1/0 Instrumentation Products and Applications 1 Instrumentation Safety barriers I.S. Isolators - DIN rail mounting - Eurocards - Modules Remote I/O Operating and monitoring systems Instrumentation systems

More information

GL-CO-RFG Channel Gas Leak Alarm System

GL-CO-RFG Channel Gas Leak Alarm System Four Elms Road Edenbridge Kent TN8 6AB UK Features & Benefits Remote sensors for natural gas, LPG and CO 1 x SPST relay outputs DIN-rail as standard, panel mounting kit available Adjustable alarm thresholds

More information

Danfoss gas detection units

Danfoss gas detection units Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning

More information

Warranty Registration

Warranty Registration WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free from defects in workmanship and materials for a period

More information

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system INSTRUCTION MANUAL 1MN0110 REV. 0 operates with ISO9001 certified quality system TECSYSTEM S.r.l. 20094 Corsico (MI) Tel.: +39-024581861 Fax: +39-0248600783 http://www.tecsystem.it R. 1.1 25/08/16 ENGLISH

More information

Fire and Gas Monitoring Panel ST7-HV

Fire and Gas Monitoring Panel ST7-HV Fire and Gas Monitoring Panel ST7-HV INTRODUCTION TO THE ST7-HV SYSTEM The ST7-HV system is a programmable PLC suitable for safety and security installations with a high technological and economic content

More information

Installation and Wiring 1.

Installation and Wiring 1. Installation and Wiring 1. Please read the Security Notifications in detail firstly. 2. The gas detector might install on wall or steel plate, please refer following drawing to make marking then drill

More information

Inc Series Digital Gas Detector/Controller. Operation Manual

Inc Series Digital Gas Detector/Controller. Operation Manual 5 Series Digital Gas Detector/Controller Operation Manual TABLE OF CONTENTS 1. 2. 3. 4. 5. 6. 7. General Description 1.1 Applications 1.2 Features Model Selection Guide Characteristics Installation 4.1

More information

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control. Détecteur de gaz OLCT80 Detectors-Transmitters for Flammable, Toxic Gases and Oxygen Non-intrusive operation via intrinsically safe infrared remote control Disponible en version déportée, ADF ou de SI

More information

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM User Instructions For The Model 5200 Gas Monitor System To completely customize the specifications to your exact application, modifications to the following

More information

Beacon 800 Gas Monitor Operator s Manual

Beacon 800 Gas Monitor Operator s Manual Beacon 800 Gas Monitor Operator s Manual Part Number: 71-0037RK Revision: F Released: 4/18/17 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment sold by us to be

More information

HALOGUARD IR MULTI-POINT, COMPOUND SPECIFIC MONITOR INSTRUCTION MANUAL

HALOGUARD IR MULTI-POINT, COMPOUND SPECIFIC MONITOR INSTRUCTION MANUAL HALOGUARD IR MULTI-POINT, COMPOUND SPECIFIC MONITOR INSTRUCTION MANUAL S E R I A L N O. M O D E L N O. T e m p. R a n g e 1 - = > 6 0 o F 2 - = 4 0-6 0 o F 3 - = < 4 0 o F - G a s T y p e 1 - R -1 1 2

More information

RS Pro Infrared Temperature Sensor

RS Pro Infrared Temperature Sensor Instruction Manual RS Pro Infrared Temperature Sensor Stock Number: 161-8103 Introduction The RS Pro Infrared Temperature Sensor is a device for measuring the temperature of the surface of a solid or liquid

More information

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08 Beacon 200 Gas Monitor Operator s Manual Part Number: 71-2102RK Released: 6/6/08 Table of Contents Chapter 1: Introduction.................................................3 Overview.............................................................3

More information

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual BS-316 Gas detection control panel up to 16 inputs Installation operation manual Page 1 from 21 Contents 1 Operation instructions--------------------------------------------------------------------------------------------------------------------3

More information

PERMACONN PM1030 Includes DI300. Installation Manual

PERMACONN PM1030 Includes DI300. Installation Manual PERMACONN PM1030 Includes DI300 Installation Manual Radio Data Comms Unit 5/20-30 Stubbs Street Silverwater NSW 2128 Telephone: 02 9352 1777 Facsimile: 02 9352 1700 Introduction The PERMACONN system provides

More information

Sierra Series 900 Single & Dual Channel System. Instruction Manual

Sierra Series 900 Single & Dual Channel System. Instruction Manual Series 240/24 Instruction Manual Table of Contents Sierra Series 900 Single & Dual Channel System Instruction Manual Part Number IM-90-07/05 Revision D. 5 Harris Court, Building L Monterey, CA 93940 (83)

More information

Analog Input Module IC670ALG630

Analog Input Module IC670ALG630 1 IC670ALG630 The Thermocouple (IC670ALG630) accepts 8 independent thermocouple or millivolt inputs. Module features include: Self calibration Two data acquisition rates based on 50 Hz and 60 Hz line frequencies

More information

PolyGard Controller LGC/LG2-04. Multi-Point Controller Serial Number S00 User Manual Preliminary Version. August 11, 2006

PolyGard Controller LGC/LG2-04. Multi-Point Controller Serial Number S00 User Manual Preliminary Version. August 11, 2006 PolyGard Controller LGC/LG2-04 Multi-Point Controller Serial Number S00 User Manual Preliminary Version August 11, 2006 January 04, 2016 Revision Specifications subject to change without notice. USA 160104

More information

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number Worldwide Supplier of Safety Solutions GfG Instrumentation 1194 Oak Valley Drive #20 Phone: 734-769-0573 Fax: 734-769-1888 E-Mail: info@gfg-inc.com Internet: www.gfg-inc.com GMA 301 Operation Manual Part

More information

OWNERS MANUAL MODEL 451 (-101 & -201)

OWNERS MANUAL MODEL 451 (-101 & -201) OWNERS MANUAL MODEL 451 (-101 & -201) Guardian Avionics CO Guardian, LLC. 1951 E Airport Drive Tucson, AZ 85756 Phone: 520-889-1177 8:00 am - 5:00 pm MST support@guardianavionics.com 2 Table of Contents

More information

Model 9010 and 9020 Monitoring Systems

Model 9010 and 9020 Monitoring Systems Model 9010 and 9020 Monitoring Systems Instruction Manual "! WARNING THIS MANUAL MUST BE CAREFULLY READ BY ALL INDIVIDUALS WHO HAVE OR WILL HAVE THE RESPONSIBILITY FOR USING OR SERVICING THE PRODUCT. Like

More information

Gasmonitor+ Installation, Operation and Maintenance Manual

Gasmonitor+ Installation, Operation and Maintenance Manual M07210 Issue 8 February 2015 Notes: The equipment described in this manual may have mains voltages applied to it. Ensure correct safety procedures are adopted before working on the equipment. The equipment

More information

GS300M Gas Detector. Features. Application. Operation

GS300M Gas Detector. Features. Application. Operation GS300M Gas Detector Microprocessor control Wall or panel mounted 3 zone protection 4-0mA signal input Measuring range 0-0% LEL / 0-300ppm P44 protective rating EN5094 for explosive gases EN509 for toxic

More information

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL OWNERS MANUAL CARBON MONOXIDE DETECTOR MODELS Panel mount and Remote Detectors (R) (353 and 353R) 353 FAMILY MODEL OWNERS/INSTALLATION MANUAL Page 1 of 22 LOG OF REVISIONS REV NO. PAGE NO. DATE DESCRIPTION

More information

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08 GasScanner 8C Eight Channel Monitor Operator s Manual MINT-0281-XX Rev. A 01/29/08 Product Warranty Matheson Tri-Gas, Inc., warrants gas alarm equipment sold by us to be free from defects in materials,

More information

GS100M Gas Detector. Technical Specification

GS100M Gas Detector. Technical Specification GS00M Detector Application Duomo is recognised within the Gas industry for providing a comprehensive range of low cost, high reliability gas detection for many applications. We have installed and commissioned

More information

Beacon 410A Gas Monitor Operator s Manual

Beacon 410A Gas Monitor Operator s Manual Beacon 410A Gas Monitor Operator s Manual Part Number: 71-0397 Revision: F Released: 12/5/17 www.rkiinstruments.com Product Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be

More information

USER MANUAL FOR OPERATING SYSTEM

USER MANUAL FOR OPERATING SYSTEM P2262 ALARM PANEL USER MANUAL FOR OPERATING SYSTEM 21765-07 September 1999 Associated Controls (Aust) PTY. LTD. 29 Smith Street, Hillsdale, NSW, 2036. PH (02) 9311 3255, FAX (02) 9311 3779 Page 1 of 177

More information

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB Summary 1 CONNECTIONS... 3 1.1 TEMPERATURE PROBES...3 1.2 LOW VOLTAGE DIGITAL INPUTS...3 1.3 LIVE DIGITAL INPUTS...4 1.4 RELAY OUTPUTS...5 2 POWER SUPPLY... 6 3 SERIAL CONNECTIONS... 6 4 SOFTWARE... 7

More information

Sierra Model 951 Digital Flo-Box. Instruction Manual Part Number IM-951 Revision A 09-05

Sierra Model 951 Digital Flo-Box. Instruction Manual Part Number IM-951 Revision A 09-05 Sierra Model 951 Digital Flo-Box Instruction Manual Part Number IM-951 Revision A 09-05 5 Harris Court, Building L Monterey, CA 93940 (831) 373-0200 (800) 866-0200 Fax (831) 373-4402 www.sierrainstruments.com

More information

UNI-TRAN PREMIUM PLUS TOXIC GAS DETECTOR USER MANUAL UT-P+-STXXXX

UNI-TRAN PREMIUM PLUS TOXIC GAS DETECTOR USER MANUAL UT-P+-STXXXX UNI-TRAN PREMIUM PLUS TOXIC GAS DETECTOR USER MANUAL UT-P+-STXXXX (Picture of ST1200 Premium Plus Toxic Gas Detector) Part Number: MAN-0005-00 Rev. 3 Copyright 2003 Net Safety Monitoring Inc. Printed

More information

Danfoss gas detection unit Type GD Heavy Duty

Danfoss gas detection unit Type GD Heavy Duty Data sheet Danfoss gas detection unit Type GD Heavy Duty The Heavy Duty gas detection units are used for monitoring and warning of hazardous Ammonia gas concentrations. They are intended for ATEX/ IECEx

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET S p e c i f i c a t i o n WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 700 D e t e c t o r C o n t r o l P a n e l Wall mounting 24V DC or 110/230vAC operation

More information

Operation Manual. Rev. D GEM-II Self-Contained Gas Detector.

Operation Manual. Rev. D GEM-II Self-Contained Gas Detector. Operation Manual Rev. D 2012.04 GEM-II Self-Contained Gas Detector www.critical-environment.com Rev. D 2012.04 GEM-II Operation Manual TABLE OF CONTENTS 1 POLICIES... 5 1.1 Important Note... 5 1.2 Warranty

More information

Halton SAFE / 7.14 user guide and installation instructions

Halton SAFE / 7.14 user guide and installation instructions Halton SAFE / 7.14 user guide and installation instructions VERIFIED SOLUTIONS BY H A LTO N Enabling Wellbeing Table of contents 1 System description 3 2 User Accounts 4 3 Main menu 7 3.1 Main menu - Change

More information

Crowcon XgardIQ. Intelligent Gas Detector and Transmitter. Installation, operating and maintenance instructions M070030/SF

Crowcon XgardIQ. Intelligent Gas Detector and Transmitter. Installation, operating and maintenance instructions M070030/SF Crowcon XgardIQ Intelligent Gas Detector and Transmitter Installation, operating and maintenance instructions M070030/SF Issue 3: June 2018 Contents 1. Introduction...1 1.1 Crowcon XgardIQ concept...

More information

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Operations Manual TS400. Test Station for G450/G460 Gas Detector TS400 Test Station for G450/G460 Gas Detector Operations Manual 1194 Oak Valley Dr, Ste 20, Ann Arbor MI 48108 USA (800) 959-0329 (734) 769-0573 www.gfg-inc.com GfG Products for Increased Safety Congratulations

More information

SAFETY MANUAL. Intelligent Sensors for H 2 S Gas Applications

SAFETY MANUAL. Intelligent Sensors for H 2 S Gas Applications SAFETY MANUAL Intelligent Sensors for H 2 S Gas Applications The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically

More information

SAFETY MANUAL. PointWatch Eclipse Infrared Hydrocarbon Gas Detector Safety Certified Model PIRECL

SAFETY MANUAL. PointWatch Eclipse Infrared Hydrocarbon Gas Detector Safety Certified Model PIRECL SAFETY MANUAL PointWatch Eclipse Infrared Hydrocarbon Gas Detector SIL 2 Certified Model PIRECL Safety Certified Model PIRECL PointWatch Eclipse IR Gas Detector This manual addresses the specific requirements

More information

Instruction Manual Model Backup Switch, 1 for 8

Instruction Manual Model Backup Switch, 1 for 8 Instruction Manual Model 2582-282 Backup Switch, 1 for 8 December 2011, Rev. 0 MODEL 2582 SWITCH CROSS TECHNOLOGIES INC. SWITCH ALARM PSA PSB ALARM OFFLINE ONLINE UNIT STATUS 1 2 3 4 5 6 7 8 BU PROT MODE

More information

GAS MONITOR Model Model

GAS MONITOR Model Model Sierra Monitor Corporation 1991 Tarob Court, Milpitas, CA 95035 (408) 262-6611 (800) 727-4377 (408) 262-9042 - Fax E-mail: sierra@sierramonitor.com Web Site: www.sierramonitor.com GAS MONITOR Model 2350-00

More information

Operation Manual. Rev. E GEM-II Self Contained Gas Detector.

Operation Manual. Rev. E GEM-II Self Contained Gas Detector. Operation Manual Rev. E 2014.10 GEM-II Self Contained Gas Detector www.critical-environment.com GEM-II - Operation Manual Rev. E 2014.10 Table of Contents 1 POLICIES... 5 1.1 Important Note...5 1.2 Warranty

More information

SEC Signature Process Gas Analyzer

SEC Signature Process Gas Analyzer SEC Signature Process Gas Analyzer Instruction and Operation Manual Sensor Electronics Corporation 5500 Lincoln Drive Minneapolis, Minnesota 55436 USA (952) 938-9486 Fax (952) 938-9617 email sensor@minn.net

More information

Mark 25 Ultrapure Water Conductivity Analyzer

Mark 25 Ultrapure Water Conductivity Analyzer Martek Instruments, Inc. Mark 25 Ultrapure Water Conductivity Analyzer Instruction Manual WARRANTY POLICY Unless otherwise stated, MARTEK INSTRUMENTS, INC. warrants this equipment to be free from defects

More information

Manual# User s Manual. 200E Series. DCU 210E/208E Diesel Engine Control Unit RP 210E Remote Panel

Manual# User s Manual. 200E Series. DCU 210E/208E Diesel Engine Control Unit RP 210E Remote Panel Manual# 1006494 User s Manual 200E Series DCU 210E/208E Diesel Engine Control Unit RP 210E Remote Panel User's Manual Rev. 1.0 Marine Pro 200E Series ~~~ DCU 210E Diesel Engine Control Unit DCU 208E Diesel

More information

AC300WR 300 WATT REDUNDANT HF-20A CHASSIS POWER SUPPLY/SYSTEM MONITOR TECHNICAL MANUAL

AC300WR 300 WATT REDUNDANT HF-20A CHASSIS POWER SUPPLY/SYSTEM MONITOR TECHNICAL MANUAL AC300WR 300 WATT REDUNDANT HF-20A CHASSIS POWER SUPPLY/SYSTEM MONITOR TECHNICAL MANUAL October 2003 Revision A Copyright October 2003 VERSITRON, Inc 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com

More information

21-light Remote Annunciator. Owner s Manual

21-light Remote Annunciator. Owner s Manual 21-light Remote Annunciator Owner s Manual Annunciator Description... Inside Font Cover Detailed Specifications... 1 Environmental Specifications... 1 Power Supply Requirements... 1 Communication With

More information

Portable Gas Detector RP110. User Guide. Explosive gas detection SEMICONDUCTOR sensor technology Intrinsically safe. Conformity EMC EN50270.

Portable Gas Detector RP110. User Guide. Explosive gas detection SEMICONDUCTOR sensor technology Intrinsically safe. Conformity EMC EN50270. Belonging Portable Gas Detector RP110 The RP110 portable gas detector is an electronic instrument manufactured by BEINAT S.r.l. to help technicians during testing or to search for and locate leaks in gas

More information

Instructions R8471J Gas Controller for use with Model OPECL Open Path Eclipse IR Gas Detector 1.1 1/

Instructions R8471J Gas Controller for use with Model OPECL Open Path Eclipse IR Gas Detector 1.1 1/ Instructions R8471J Gas Controller for use with Model OPECL Open Path Eclipse IR Gas Detector 1.1 1/08 Table Of Contents Section I Installation and Startup.................. 1 INSTALLATION............................................

More information

User Manual. PolyGard Gas Controller MGC3. Two-Channel Analog Gas Controller Serial Number _E _0907. September 2007

User Manual. PolyGard Gas Controller MGC3. Two-Channel Analog Gas Controller Serial Number _E _0907. September 2007 PolyGard Gas Controller MGC3 Two-Channel Analog Gas Controller Serial Number _E _0907 User Manual September 2007 January 04, 2016 Revision Specifications subject to change without notice. USA 160104 Page

More information

OVEN INDUSTRIES, INC.

OVEN INDUSTRIES, INC. OVEN INDUSTRIES, INC. OPERATING MANUAL Model 5C7-252 TEMPERATURE CONTROLLER With PLC Inputs Introduction Thank you for purchasing our controller. The Model 5C7-252 is an exceptionally versatile unit and

More information

SUPREMATouch. Modular Fire & Gas Detection System

SUPREMATouch. Modular Fire & Gas Detection System SUPREMATouch Modular Fire & Gas Detection System Tel: +44 (0)8 9388 Email: info@ Fire & Gas Detection Solutions MSA permanent gas detection systems are used throughout the world to protect plant and personnel

More information

SACE PR021/K SIGNALLING UNIT

SACE PR021/K SIGNALLING UNIT SACE PR021/K SIGNALLING UNIT 1SDH000559R0002 L3016 1/52 EN CONTENTS 1. GENERAL INFORMATION...4 1.1. FOREWORD...4 1.2. APPLICABLE SCENARIOS...5 2. TECHNICAL SPECIFICATIONS...6 2.1. ELECTRICAL CHARACTERISTICS...6

More information

A series of technical features make this gas detector extremely versatile, reliable, accurate, and safe.

A series of technical features make this gas detector extremely versatile, reliable, accurate, and safe. Belonging to Made in Italy GS911K Gas Detector GS911K Using the catalytic sensor inside it, the GS911K detector detects the presence of explosive gas such as: Methane, LPG, with trip sensitivity calibrated

More information

DESIGN MANUAL MODEL GIR900 INFRARED COMBUSTIBLE GAS SENSOR

DESIGN MANUAL MODEL GIR900 INFRARED COMBUSTIBLE GAS SENSOR DESIGN MANUAL MODEL GIR900 INFRARED COMBUSTIBLE GAS SENSOR 70086 The information in this doucment is applicable to sensors built in September, 2008 or later (Firmware 3.0) The information and technical

More information

GAS PLUS ALARM SYSTEM

GAS PLUS ALARM SYSTEM GAS PLUS -IR SERIES 4688-IR COMBUSTIBLE GAS OR CARBON DIOXIDE TRANSMITTER GAS PLUS -IR TRANSMITTER SERIES 4688-IR COMBUSTIBLE GAS OR CARBON DIOXIDE TRANSMITTER The Scott Gas Plus -IR Model 4688 IR Gas

More information

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504 Remote Monitor PTE0700 SECURITY ELECTRONICS User Manual PTE0700 V2 Series Remote Monitor Pakton Technologies Pty Ltd ABN 66 405 694 842 16 Ferrier Road, Narangba Qld 4504 PO Box 408, Narangba QLD 4504

More information

Entwicklung + Fertigung + Service: Heerweg 15 D, Denkendorf Tel.: / Fax.: /

Entwicklung + Fertigung + Service: Heerweg 15 D, Denkendorf Tel.: / Fax.: / Planungsbüro + Service: Esteraustr. 10, 56379 Holzappel Tel.: 0 64 39 / 90 19 90 Fax.: 0 64 39 / 90 19 91 E-Mail: u.ramakers@umsitec.de Entwicklung + Fertigung + Service: Heerweg 15 D, 73770 Denkendorf

More information

SIL 2. Ultima X Series Gas Monitors CERTIFIED

SIL 2. Ultima X Series Gas Monitors CERTIFIED Ultima X Series Gas Monitors 5 Now with SIL 2 CERTIFIED Products Versatile fixed instruments provide continuous monitoring of many hazardous gases using catalytic, electrochemical, and infrared gas detection

More information

PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases

PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases DESCRIPTION Gas measuring and monitoring controller based on stateof-the-art microtechnology with integrated sensor for continuous monitoring

More information

RK Carbon Monoxide Transmitter Operator s Manual

RK Carbon Monoxide Transmitter Operator s Manual 65-2432RK Carbon Monoxide Transmitter Operator s Manual Part Number: 71-0070RK Revision: P1 Released: July 8, 2001 RKI Instruments, Inc. 1855 Whipple Road Hayward CA 94544 Phone: 800-754-5165 Fax: 510-441-5650

More information

SAFETY MANUAL. Multispectrum IR Flame Detector X3301

SAFETY MANUAL. Multispectrum IR Flame Detector X3301 SAFETY MANUAL Multispectrum IR Flame Detector X3301 SAFETY-CERTIFIED MODEL X3301 MULTISPECTRUM INFRARED DETECTOR This manual addresses the specific requirements and recommendations applicable to the proper

More information

STATUS ALARM HISTORY ALARM RESET

STATUS ALARM HISTORY ALARM RESET Instruction Manual Model 1582-42L Data Switch February 1999, Rev 0 CH1 AUTO CH2 SWITCH 1 2 1 2 STATUS 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 ONLINE MANUAL SELECT CH2 ONLINE SWITCH RESET MAN

More information

Crowcon XgardIQ. Intelligent Gas Detector and Transmitter. Installation, operating and maintenance instructions M070030

Crowcon XgardIQ. Intelligent Gas Detector and Transmitter. Installation, operating and maintenance instructions M070030 Crowcon XgardIQ Intelligent Gas Detector and Transmitter Installation, operating and maintenance instructions M070030 Issue 2, November 2016 Contents 1. Introduction...1 1.1 Crowcon XgardIQ concept...

More information

UNI-TROL TM GAS CONTROLLER

UNI-TROL TM GAS CONTROLLER MODELS: R1G, R2G and R4G UNI-TROL TM GAS CONTROLLER One, Two and Four-Channel Rack-Mount Controller ISO 9001 Certified Company Part Number: MAN-0004 Rev. 1 Copyright 2002 Net Safety Monitoring Inc. Printed

More information

Vocia VACIE. Reference Guide

Vocia VACIE. Reference Guide Vocia VACIE Reference Guide Document Revision 1.2.3, August 2015 Biamp Systems 9300 SW Gemini Drive Beaverton, Oregon 97008, U.S.A. (503) 641-7287 www.biamp.com INTRODUCTION... 3 SECTION 1... 4 VACIE CONFIGURATION...

More information

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

STATUS ALARM ALARM HISTORY POWER HISTORY RESET Instruction Manual Model 1582-70L2 RF Switch June 2011, Rev. D CH1 AUTO CH2 SWITCH 1 2 1 2 STATUS 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 ONLINE MANUAL SELECT CH2 SWITCH MANUAL REMOTE ONLINE

More information

ESSEX ENGINEERING CORPORATION

ESSEX ENGINEERING CORPORATION WATER/WASTEWATER TREATMENT CONTROL SYSTEMS AND SUBSYSTEMS 2000 SERIES CONTROL SYSTEMS: 2000 series are for surface mounting inside a control cabinet Model 2024 Electronic Alternator Duplex (two pump) pump

More information

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point Medium - Control - System Franke & Haqenest GmbH Borngasse 1a * 04600 Altenburg Tel: 03447-499 313-0 Fax: 03447-499 313-6 email: info@mcs-gaswarnanlagen.de MCS User Guide MCS GasController Microprocessor

More information

Danfoss gas detection units

Danfoss gas detection units Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning

More information