3. Compatible Sensor Wiring 4. Batch Contact Wiring See section 9 for simple and advanced mode configuration options.

Size: px
Start display at page:

Download "3. Compatible Sensor Wiring 4. Batch Contact Wiring See section 9 for simple and advanced mode configuration options."

Transcription

1 GF SIGNET ontroller Instructions B1/98 ENGLISH AUTION! Refer to this instruction manual for more details. Remove power to unit before wiring input and connections. Follow instructions carefully to avoid personal injury. ontents 1. Dial Selection 2. Power onnection 3. ompatible Sensor Wiring 4. ontact Wiring 5. Remote ontrol Wiring 6. End of /ounter Pulse Output Wiring 7. ontact Wiring s 8. urrent Output Wiring s 9. Operation Modes 10. Menu Functions 11. Parts and Accessories 12. Specifications 13. Quick Reference Menu Parameters 14. Maintenance 15. Troubleshooting 1. Dial Selection The analog display shows percentage of batch complete 0 100%, or percentage of remaining batch 100 0% on the reversible dial face plate. Meter deflection is fixed from left to right. The instrument is shipped with the percentage of batch complete 0 100% scale shown. Reverse the face plate for either scale, as desired. 2. Power onnection AUTION! Never connect 115 VA or 230 VA to rear power terminals. High voltage A will damage instrument and void warranty. A B % 100 ALARM 1 ALARM 2 0 % ALARM 1 ALARM 2 D = Double Insulated = D or A power 1224 V 10 W External power supply VD OR VA Maximum 420 ma loop impedance (sec. 8A) is affected by the supply voltage. To reduce the possibility of noise interference, isolate A power lines from signal lines. 3. ompatible Sensor Wiring 4. ontact Wiring See section 9 for simple and advanced mode configuration options. Freq. IN Std. Sensor Freq. IN Sen. Pwr. Iso. Gnd Open ollector Sensor GF SIGNET Sensors: Red 515 Black Shld. Red Black Shld Vortex* flow N valve N A or D power To reduce the possibility of noise interference, route sensor cable away from A power lines. *Vortex sensor or system frequency Maximum alarm contact ratings: 5 30 VD, VA, or VA To reduce the possibility of noise interference, isolate A power lines from signal lines.

2 5. Remote ontrol Wiring Rear START, STOP, and RESUME (Rsm) terminals can provide remote batch control from a distance using one of four methods: Mechanical switch closures (shown) End of batch pulse from a second (sec. 6) End of batch contact closure from a second (sec. 7). End of batch current pulse from a second (sec. 8). Momentary Switch ontacts (customer supplied) Remote Rsm RTN Resume 6. End of /ounter Pulse Output Wiring See section 9 for simple and advanced mode configuration options. A. External counter connection 10 kω Gnd NT/EOB IN Gnd 5 30 VD External ounter Daisy chaining two batch controllers together Gnd NT/EOB Remote Rsm RTN First Second Use 4conductor shielded cable for remote control lines up to 30 m (100 ft) max. Use 2conductor shielded twistedpair cable for lines up to 30 m (100 ft.) max. 7. ontact Wiring s A. Two Stage Shutdown (advanced mode only, sec. 9.2) 8. urrent Output Wiring s A. ompletion (simple or advanced mode, sec. 9) N N Fuse** 1/8A * 4 20 ma Bypass line A or D power urrent Main line flow Valve to tank **1/8A fuse recommended (customer supplied) * 420 ma is internally powered (nonisolated), maximum loop impedance 350 Ω with a 12 V instrument supply voltage, 950 Ω with a 24 V instrument supply voltage. Maximum alarm contact ratings: 5 30 VD, VA, or VA To reduce the possibility of noise interference, isolate A power lines from signal lines. To isolate and prevent ground loop problems: 1. Use monitor device with isolated inputs, or 2. Use separate D supply for and monitor device, or 3. Power with VA step down transformer Alarm (simple or advanced mode, sec. 9) OR Overrun Alarm (advanced mode only, sec. 9.2) Valve ontrol (advanced mode only, sec. 9.2) #5 ( ) 4 20 ma #6 ( ) Alarm device N N A or D power urrent George Fischer electronic actuator with PE 22P positioner required Maximum alarm contact ratings: 5 30 VD, VA, or VA To reduce the possibility of noise interference, isolate A power lines from signal lines. Output compatible with the following George Fischer electronic actuators/pe 22P positioner models: EA 20, EA 30, EA 41, and EA 50

3 Section 7 ontinued.... End of Pulse (advanced mode only, sec. 9.2) Daisy chaining two batch controllers together for a second batching stage. Section 8 ontinued.... End of Pulse (advanced mode only, sec. 9.2) Daisy chaining two batch controllers together for a second batching stage. N N First Second Rsm Remote Use 2conductor shielded twistedpair cable for contact lines up to 30 m (100 ft.) max. RTN urrent Remote Rsm RTN First Second Wiring MUST be connected exactly as shown. Use 2conductor shielded twistedpair cable for lines up to 30 m (100 ft) max. 9. Operation Modes This section gives a detailed description of the 's simple and advanced operation modes (sec. 14) and how they affect the batch contact, End of batch/totalizer, option contact, and current. 9.1 Simple Operation Mode ontact (sec. 4): In simple mode, the batch contact is dedicated for on/off control. It is energized at the start of a batch and deenergized at the end of a batch. It also deenergizes when STOP is selected from the front keypad or initiated by a remote contact closure to the rear STOP terminals (sec. 5). A RESUME command can also be initiated by either method to complete the batch. The front panel batch indicator turns on when the batch contact is energized. ounter/end of Pulse Output (sec. 6): In simple mode, the is configured as a counter pulse. The emits a 130 millisecond pulse for each engineering (total) unit measured. The is a open collector type which requires an external pull up resistor and power supply for external counter use (sec. 6). ontact Alarm (sec. 7B): This function provides alarm capability if flow is not detected in 30 seconds after a batch cycle starts. If the flow sensor signal is missing, the option contact energizes and the front panel contact indicator turns on, signaling the missing sensor signal. The batch contact also deenergizes, closing the flow control valve and stopping the batch. The alarm condition will remain until the front panel key is ed or a remote contact closure is made to the rear STOP terminal (sec. 5). started... Sensor input option contact batch contact urrent Output ompletion (sec. 8A): This function is offered in the simple or advanced operation mode. The is a linear increase from 4 ma at batch start to 20 ma at batch end. running... 0% 4 ma 100% 20 ma 9.2 Advanced Operation Mode Overrun omp: automatic manual ontact (sec. 4) The batch contact is dedicated for on/off control and is either manually or automatically compensated for batch overrun. Manual overrun compensation allows the operator to compensate for valve closure time in a batching system. The operator is prompted to enter a batch volume that deenergizes the batch contact early, compensating for valve closing time and eliminating batch overrun. Automatic overrun compensation counts sensor pulses during the batch cycle, and any excess pulses after the batch stops. The instrument calculates the estimated batch overrun based on the additional sensor pulses, then automatically reduces the next batch size for the next batch. During the next batch cycle, the batch contact deenergizes early, thus closing the flow control valve early and eliminating batch overrun. ounter/end of Pulse Output (sec. 6): In advanced mode, the can be configured as either a counter pulse (sec. 9.1) or as an end of batch pulse. When configured as an end of batch pulse, the emits a 500 millisecond pulse at the completion of every batch. The is a open collector type which requires an external pull up resistor and power supply for external counter use (sec. 6).

4 Two Stage ontact Two Stage Shutdown (sec. 7A): This function is designed to prevent over filling or to minimize water hammer. Both the batch and the option contact are energized when the batch starts. The option contact then deenergizes at a programmed batch percentage, forcing flow through a smaller bypass line to reduce the fill rate. After the entire batch is measured, the batch contact deenergizes, completing the sequence. Front keypad and remote START, STOP, and RESUME inputs (sec. 5) also control the option contact. The front panel contact indicator turns on when the option contact is energized. running... 0% contact batch contact 100% 90% Overrun Alarm ontact Overrun Alarm (sec. 7B): This function provides overrun alarm capability for detecting a leaky or stuck valve. If the programmed batch overrun volume is measured after the batch ends, the option contact is energized and the front panel contact indicator turns on, alarming the operator that the flow shut off valve is leaking or stuck open. To cancel alarm, the key (or remote STOP switch) once. The overrun alarm will retrigger if the condition persists. running... 0% contact batch contact Overrun 100% End of ontact End of Pulse (sec. 7): This function is designed to trigger an external batch counter or second ontroller at the end of a batch. The option contact is energized for 500 milliseconds at the end of every batch cycle. An external power supply switched through the option contact's common (OM) and normally open () terminal provides a pulse for triggering these devices. running... 0% contact batch contact 100% 500ms ontact Alarm (sec. 7B): The missing signal alarm represents a missing sensor signal after batch startup. An adjustable time delay entry (in seconds) is offered which specifies how long the instrument will wait after batch startup before initiating the missing signal alarm. See simple operation mode (sec. 9.1) for alarm operation details. Off ontact On/Off (sec. 10.4H): This function enables or disables the option contact and front panel option LED. When the option contact is configured "Off", the option contact and front panel LED are disabled. Alarm On/Off (sec. 10.4H): Alarm: On Missing signal alarm is always enabled (factory default sec. 9.1) even if the option contact is selected to be a different function. This function is designed to completely disable the missing signal alarm, if desired. TE: If disabled, the batch contact is T affected and will T signal the operator or stop the running batch if there is a problem. urrent Output: ompletion urrent Output ompletion (sec. 8A): In advanced mode, the current functions identical to the simple operation mode. See the simple operation mode explanation above. urrent Output: Valve ontrol urrent Output Valve ontrol (sec. 8B): This function is designed for use with a George Fischer electric actuator with PE 22P positioner for preventing overflow or minimizing water hammer. When a batch starts, the current is held at 20 ma, forcing the PE 22P positioner to the full open valve position. Near batch end, the gradually ramps downward to slow the flowrate, then drops to 4 ma closing the valve and ending the batch. Front keypad and remote START, STOP, and RESUME inputs also control the (sec. 5). A STOP command any time during a batch sequence will force the to 4 ma and close the PE 22P positioner. (Note: for optimum performance, the batch process should last at least 1 minute!) running... 0% valve 100% 20 ma 4 ma valve urrent Output: End of urrent Output End of (sec. 8): This function is designed to trigger a second batch controller's remote START input for a second batching stage. When the batch starts, the current remains at 0 ma until the end of the batch, then jumps to 20 ma for 500 milliseconds. The 500 millisecond current pulse triggers the second 's remote START terminal to start the second batch stage. running... 0% 0 ma 100% 20 ma 500ms

5 10. Menu Functions *Note: BATH/VIEW Menu steps B E MUST be selected for ALIBRATE Menu (sec. 10.2) or OPTIONS Menu (sec. 10.4) access. ALIBRATE (sec. 10.2) OPTIONS (sec. 10.4) Press & hold key for menu access: BATH/ VIEW (See Note*) 2 seconds 5 seconds Menus: BATH/VIEW menu (sec. 10.1): The BATH/VIEW menu is displayed during standard operation. The key controls batch start, batch stop, and batch resume operations. While a batch is not running, the operator can navigate freely through the menu by ing either UP or DOWN arrow keys. While a batch is running, ing either UP or DOWN arrow keys displays Time left, Flow rate, and Volume batched information. The BATH/ VIEW menu also offers a programmable batch size and resettable totalizer feature that allows the operator to reset the displayed total at the of a button. ALIBRATE Menu (sec. 10.2): The ALIBRATE menu contains all critical display setup and parameters. A simple security code feature prevents unauthorized tampering. The operator is required to enter a simple access code for menu access. The same code also unlocks OPTIONS menus. OPTIONS Menu (sec. 10.4): The OPTIONS menu contains setup and display features that are seldom accessed for minor display or adjustments BATH/VIEW Menu (example) Menu steps B E cannot be accessed when a batch is running. Press to stop batch cycle. Steps B E MUST be selected for ALIBRATE Menu (sec. 10.2) or OPTIONS Menu (sec. 10.4) access. To Step E A. Resume or start Main ing Sequence Volume: Gallons> Programmable Volume To step 0.0 Gallons <> to 40.3 Gallons <> to Volume batched 40.3 Gallons Resume Resume or start (sec. 10.4D) OPTIONS = Volume: Gallons 1. Enter volume 2. OR Save To exit without changes: ount Up selected (sec.10.4k) While a batch is running... Volume: Key ode: Volume: Key ode: **** 1. Enter code: 3. Time Left: <1 min <> to Time Left 60.5 Gallons/m <> to (sec. 10.4D) OPTIONS = Volume: Gallons 2. Enter volume Flow rate 40.3 Gallons <> to Volume batched Save Back to Step B. D. Gallons X 1 Total: > Resettable Totalizer Gallons X 1 Total: Permanent Total Overrun: Manual Gallons Overrun compensation (sec. 10.4D) OPTIONS = OR Reset Total? Press to reset Reset Total? To exit without changes: (sec. 10.4D) OPTIONS = Reset Total? Key ode: Reset Total? Key ode: **** 1. Enter code: Reset Total?: D. Permanent Total cannot be reset. Press to reset Reset Total?: E. E. Shown only when "advanced" mode is chosen To step A (sec. 10.4E)

6 10.2 ALIBRATE Menu (factory defaults shown in menu column 1) ALIBRATE: Enter Key ode Press keys in sequence to continue, **** will appear during code entry. G A. 1 hoose: Units: Gallons > units Units: Liter 2 hange: Set batch units: Aa Zz, 0 9, /, _ 3 Save: Back to step D. KFactor: > KFactor KFactor: Set batch KFactor: (see note*) Flow Timebase: m > Flow timebase Flow Time Base: s S m M h H d D Set timebase: S=seconds, M=minutes, H=Hours, D=Days E. Total Units: Gallons x 1 > Totalizer units Total Units: Liters X100 Set totalizer units: Az Zz, 0 9, /, _ (Label use only). Auto alibrate: KFactor > Auto alibrate Procedure Accurate reference container required. See procedure (sec. 10.3) Display shown only when advanced mode (sec.10.4e) and manual overrun comp. (sec.10.4g) is selected. To return to VIEW: To step D Auto alibrate: <> to Auto alibrate: <> to Auto al Volume: XX.XXX Gallons A. Reenter volume? Enter volume KFactor: Accept KFactor? Overrun Volume: XX.XXX Gallons D. Overrun comp. To restore original value: KFactor Modify KFactor? Save ancel OR Save "SAVING" briefly displays F. G. To return to VIEW: Total KFactor: > Totalizer KFactor Last AL: Last calibration To step A Total KFactor: Last AL: To restore original value: Set totalizer KFactor: (see note*) Last AL: Sets user defined date "SAVING" briefly displays *Note: and totalizer KFactor settings represent the number of pulses generated by the GF SIGNET flow sensor for each engineering unit of fluid measured (published in the flow sensor manual) Auto alibration Procedure The auto calibrate procedure (sec. 10.2) calculates a custom flow sensor/batch KFactor based on volumetric measurement for more precise batching. This process will compensate for installation abnormalities or nonstandard pipe sizes for maximum batch accuracy. An accurate measurement reference container (e.g. known tank volume) is required for this procedure. If auto calibration is impractical for your batch system, perform manual calibration using the KFactors published in your flow sensor manual. Requirements: A. The flow sensor must be installed in the actual batch pipeline. The flow control valve can be connected to the common () and normally open () batch contact terminals (sec. 4) or the current terminals (sec. 8B).. Either the batch contact or current MUST be used to energize and deenergize the main flow control valve which starts and stops fluid flow into the known reference container. D. Follow the steps outlined in the auto calibration procedure (sec. 10.2) to obtain your batch system's custom KFactor % GF SIGNET contact terminals (sec. 4) OR 420 ma valve control terminals (sec. 8B) Flow Sensor Flow control valve WARNING! The auto calibration procedure generates a custom batch KFactor. The batch and Totalizer KFactors are independent from one another. ALWAYS reenter your totalizer KFactor after performing the auto calibration procedure Reference ontainer

7 10.4 OPTIONS Menu (factory defaults shown in menu column 1) OPTIONS: Enter Key ode Press keys in sequence to continue, **** will appear during code entry. K A. 1 hoose: ontrast: 3 > ontrast ontrast: hange: Set contrast: 5 levels 3 Save: Back to step F G. Overrun omp: Manual > contact Overrun omp: Auto Manual Set overrun compensation: automatic or manual (sec. 9.2) Display Decimal: *****. * > Flow decimal Display Decimal: ****. ** Set flow decimal: ******. **. **** Overrun Volume: Gallons> contact Manual overrun comp selected (step G): Overrun Volume: Gallons Set overrun volume: D. E. F. Total Decimal: *******. * > Totalizer decimal Lock: OFF > VIEW Menu Lock Operating Mode: Advanced > Operation mode Pulse Output: Totalizer > Pulse Output Total Decimal: ******. ** Lock: Off On Operating Mode: Simple Advanced Advanced mode selected (step E) Set totalizer decimal: ********. ******. ** Set VIEW Menu lock: On= Set pulse (sec. 9.2): Pulse Output: End of Pulse Output: Totalizer Off= Set operation mode: Simple or Advanced F H End of (EOB) Totalizer (NT) "SAVING" briefly displays H. > contact Two Stage Setpoint%: 95.0> ontact Overrun Alarm: Gallons> ontact Set operation mode (sec. 9.2): Two Stage mode selected Two Stage Setpoint%: 99.5 Two Stage Overrun Alarm Overrun Alarm mode selected Overrun Alarm: Gallons End of Off Missing Signal Two Stage Overrun Alarm End of Set two stage setpoint %: Turn off Set overrun alarm volume: "SAVING" briefly displays To return to VIEW: To step G To restore original value: Two Stage, Overrun Alarm, End of, or Off mode selected Alarm: On > ontact Alarm: Off On Missing signal alarm: On or Off Menu Navigation Advanced mode chosen (step E): menu continues, steps F I. Simple mode chosen (step E): down arrow key advances to top of menu (step A). I. T shown if Alarm is Off (step H) Delay: 30.0 sec > ontact Delay: 25.0 sec Set missing signal time delay: sec. J. urrent Output: ompletion> urrent Set operation mode (sec. 9.2): urrent Output: ompletion urrent Output: Valve ontrol urrent Output: End of ompletion Valve ontrol End of K. ount Direction: Up > display count ount Direction: Up Down display count direction: Up or Down To return to VIEW: To step A To restore original value:

8 11. Parts and Accessories Splashproof rear cover # (code ) 5 x 5 inch adapter plate for GF SIGNET retrofit # (code ) al surface mount bracket # (code ) Power supply, 115 VA 24 VA, # Front snapon bezel, # (code ) instruction sheet # (code ) 12. Specifications General Sensor compatibility: Accuracy: Input: All GF SIGNET flow sensors ± 0.5% of batch reading Optically isolated Agency Approvals E Manufactured under ISO 9001 Enclosure: Rating: NEMA 4X/IP65 front Dimensions: 1/4 DIN, 96 x 96 x 88 mm (3.8 x 3.8 x 3.5 in.) ase materials: ABS plastic Keypad material: Sealed 4key silicone rubber Weight: Approximately 500 g (18 oz.) Display: Type: Microprocessor controlled aircore meter movement and alphanumeric 2 x 16 LD Update rate: <200 ms ontrast: User selected Alarm annunciators: green batch LED (left), red option LED (right) Totalizers: 8digit resettable with security option 8digit nonresettable Electrical Power: 12 to 24 VD or 12 to 24 VA, unregulated, 5060 Hz, 10 W max. ontacts (2 sets): Mechanical SPDT contacts Maximum voltage rating: 5 30 VD, VA, or VA, (power factor = 1.0) urrent : 4 to 20 ma, nonisolated, internally powered Update rate: <200 ms Max loop impedance: 350 Ω max with a 12 V instrument supply voltage, 950 Ω max with a 24 V instrument supply voltage Accuracy: ±0.1% of max range Totalizer (NT)/End of batch (EOB) pulse s: Opencollector transistor, optically isolated, 5 ma max. sink, 28 VD max. pullup voltage, 130 ms (NT) pulse width End of batch pulse 500 ms (fixed) Environmental Operating temp.: 10 to 55 (14 to 131 F), 50 (122 F) max. with optional rear cover Storage temp.: 15 to 80 (5 to 176 F) Relative humidity: 0 to 95%, noncondensing Altitude: 4000 m max. Pollution degree: 2 GND Noise immunity: Noise emissions: Safety: Internal EOB/NT ircuit 100 Ω EN EN55011 EN610101

9 Dimensions: 96 mm (3.8 in.) Panel Gasket al Splashproof Rear over (sec. 11) % mm (3.8 in.) Mounting Panel Mounting lamp (2 ea.) mm (3.8 in.) 88 mm (3.5 in.) 91 mm (3.6 in.) SIDE VIEW Front View GF SIGNET 76 mm (3 in.) 96 mm (3.8 in.) 88 mm (3.5 in.) 88 mm (3.5 in.) Freq. IN Std. Sensor Freq. IN GF SIGNET Model #3 Sen. Pwr. Iso. Gnd Open ollector Sensor 1224 V 10 W Gnd NT/EOB Rsm RTN Remote N urrent N Patent No. D 376, mm (3.5 in.) 92 x 92 mm (3.62 x 3.62 in.) Rear View Panel cutout 13. Quick Reference Menu Parameters 13.1 VIEW Menu Setup Parameters (sec. 10.1) Menu Parameters Display Description Range Factory Default A Gallons <> to Press to start, stop, or resume batch See programmed batch volume B Gallons Volume: Gallons> Programmed batch volume Gallons. Gallons X 1 Total: > Resettable totalizer D. Gallons X 1 Total: Permanent totalizer E. Overrun: Manual Gallons Overrun mode Overrun volume Manual or Auto

10 13.2 ALIBRATE Menu Setup Parameters (sec. 10.2) Menu Parameters Display Description Range Factory Default A. Units: Gallons > units Aa Zz, 0 9, /, _ (8digits max.) _Gallons _ = blank display digit option Flow Timebase: m > Flow timebase Ss, Mm, Hh, Dd m (m= minutes). Auto alibrate: KFactor > al volumetric calibration n/a n/a D. KFactor: > KFactor E. Total Units: Gallons x 1 > Total units Az Zz, 0 9, /, _ (15digits max.) Gallons X 1 _ = blank display digit option F. Total KFactor: > Total KFactor G. Last AL: Last alibration date to OPTIONS Menu Setup Parameters (sec. 10.4) Menu Parameters Display Description Range Factory Default A. ontrast: 3 > Display contrast 0 to 5 3 Display Decimal: *****. * > Flow decimal **.*** to *****. ****.*. Total Decimal: *******. * > Total decimal ******.** to ********. *******.* D. Lock: OFF > VIEW menu total/batch volume reset access code On or Off Off E. Operating Mode: Advanced > Simple or Advanced n/a Advanced F. Pulse Output: Totalizer > Pulse operation mode End of or Totalizer Totalizer G. Overrun omp: Manual > Overrun compensation mode Manual or Auto Manual Overrun Volume: Gallons> Overrun volume Gallons H. > contact mode Missing signal, Two stage, Overrun alarm, End of, Off Missing signal Two Stage Setpoint%: 95.0> contact, two stage mode 0.00 % 100. % 95.0% Overrun Alarm: Gallons> contact, overrun alarm mode Gallons Alarm: On > Missing signal alarm On or Off On I. Delay: 30.0 sec > Missing signal alarm delay seconds 0.10 seconds J. urrent Output: ompletion> urrent mode ompletion, Valve control, or End of ompletion K. ount Direction: Down > count direction ount up or down ount up

11 14. Maintenance lean the instrument case and front panel with a soft cloth and mild liquid soap solution. 15. Troubleshooting Display Problem Solution Gallons/m Display timebase too large hange flow timebase (S=Seconds, M=Minutes, H=Hours, D=Days) in <> to START ALIBRATE menu to a smaller value (e.g. GPD to GPM) Time Left min Remaining batch time greater than Display will show actual remaining minutes after the remaining batch time <> to 999 minutes (overrange) is less than 999 minutes Gallons Flow rate detected after batch end Repair leaky or stuck flow shuttoff valve. <> to Flow KFactor Flow (batch) display KFactor dan not Enter KFactor greater than zero (sec. 10.2D) can not be zero be zero Total KFactor Totalizer KFactor can not be Enter KFactor greater than zero (sec. 9.2E) can not be zero zero Must be between Missing signal time delay must be set Enter missing signal time delay within seconds (sec. 10.4I) for seconds Overrun Volume Overrun alarm volumetric setting Enter overrun alarm volumetric setpoint within ) can not be zero must be within engineering units (sec. 10.4H engineering units Power Failure Instrument power interrupted during Use RIGHT arrow key to select "Resume" or "lear". Selecting resume will Resume lear active batch process continue the batch from the point where the power interruption occurred. Selecting clear will clear the power failure. After your selection has been made, to continue. SETUP READ ERROR Power fault occurred while saving Press any key to reload factory defaults then reprogram flow system setup Press any Key setup menu entry parameters. Note: Totalizer displays remain undistrubed and will resume after instrument reset. Notes:

12 Provided by: KTH Sales, Inc. ph: Louisiana Place Merrillville, Indiana USA Signet Scientific ompany, 3401 Aerojet Avenue, El Monte, A U.S.A., PRINTED ON REYLED PAPER /(B1/98), English Signet Scientific ompany 1996 Printed in U.S.A.

7EF/7HF/7EC/7ES Temperature Controllers

7EF/7HF/7EC/7ES Temperature Controllers 7EF/7HF/7E/7ES Temperature ontrollers Dual 4 Digit LED Display Universal Input (6 T/, RTD, mv, V, ma) Autotuning NEMA 4X 100 to 240 Vac Switching Power Supply Algorithms for Heat or Heat/ool ontrol 2 Independent

More information

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL MYRIAD TPC VISIT OUR WEBSITE SIGMACONTROLS.COM MYRIADI&O062705 2 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features WIRING 7,8

More information

I/A Series 716C 1/16 DIN Temperature Controller

I/A Series 716C 1/16 DIN Temperature Controller Product Specifications I/A Series 716C 1/16 DIN Temperature Controller PSS 2C-1B5 A The Foxboro 716C is a powerful compact, 1/16 DIN, microprocessor-based temperature controller that offers a variety of

More information

Instruction Manual December 2001 ENACOCU02

Instruction Manual December 2001 ENACOCU02 SENACOCU02 Instruction Manual December 2001 ENACOCU02 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected

More information

Sierra Model 951 Digital Flo-Box. Instruction Manual Part Number IM-951 Revision A 09-05

Sierra Model 951 Digital Flo-Box. Instruction Manual Part Number IM-951 Revision A 09-05 Sierra Model 951 Digital Flo-Box Instruction Manual Part Number IM-951 Revision A 09-05 5 Harris Court, Building L Monterey, CA 93940 (831) 373-0200 (800) 866-0200 Fax (831) 373-4402 www.sierrainstruments.com

More information

Software Version 2.01 LEVEL MONITOR MODEL 220

Software Version 2.01 LEVEL MONITOR MODEL 220 Software Version 2.01 LEVEL MONITOR MODEL 220 19 April 2000 CONTENTS 1. Introduction 1 1.1 Model Number Designation 2 1.2 Intrinsic Safety Considerations 3 2. Specification 4 3. Operation 6 3.1 Display

More information

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Process & TeMPerATUre UniversAl input DigiTAl MeTers Process & TeMPerATUre UniversAl input DigiTAl MeTers nova PD56 series Thermocouple, rtd, & Process inputs Universal Power supply 1-24 va c Up to 3 Alarm relays retransmitting 4-2 ma output input Max/Min

More information

CU-02 with Senaco Plus

CU-02 with Senaco Plus CU-02 with Senaco Plus Instruction Manual PL-509 July 2001 U-02 SENACO 33455090 Rev. 1.1 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect

More information

Instruction Manual August sitrans CU 02

Instruction Manual August sitrans CU 02 Instruction Manual August 2005 sitrans CU 02 Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment.

More information

RS Pro Infrared Temperature Sensor

RS Pro Infrared Temperature Sensor Instruction Manual RS Pro Infrared Temperature Sensor Stock Number: 161-8103 Introduction The RS Pro Infrared Temperature Sensor is a device for measuring the temperature of the surface of a solid or liquid

More information

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS NOVA PD56 Series Thermocouple, RTD, & Process Inputs Universal Power Supply 1-24 VAC Up to 3 Alarm Relays Retransmitting 4-2 ma Output Input Max/Min

More information

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1 Model TRO24T4XYZ1 Description The TRO24T4XYZ1 is a combination controller and thermostat. The VAV Thermostat Controller is designed for simple and accurate control of any variable air volume box in a number

More information

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers. ModSync Sequencing System Installation & Operation Manual For use with Fulton Steam Boilers. Revision 3.0 8/21/2008 - 2 - Table of Contents Introduction Page 4 Features Page 4 Sequence of Operation Page

More information

PS914 Power Supply. 900-KL Keylock (optional) Page BB Battery Backup (optional) Page 3

PS914 Power Supply. 900-KL Keylock (optional) Page BB Battery Backup (optional) Page 3 F1! DANGER 44487056 These instructions cover the following parts: PS914 Power Supply Installation Instructions! DANGER: To avoid risk of electric shock, turn off A power before installing or servicing

More information

MODEL MP-1S OVERSPEED UNIT

MODEL MP-1S OVERSPEED UNIT MODEL MP-S OVERSPEED UNIT SPEIFIATIONS Model Spec. ode upon delivery/add l Spec. ode( not requested, leave blank ) MP-S- - - - Hysteresis Set up Monitor Range Input Signal No. of Input Pulse Trigger Mode

More information

Iecex. PD6603/7 Feet & Inches Display

Iecex. PD6603/7 Feet & Inches Display PD6600 Series Loop Leader Loop-Powered Process Meter PD6602/6 Decimal Display PD6604/8 Decimal Display with Bargraph Iecex PD6606 & PD6607, PD6608 only PD6603/7 Feet & Inches Display Loop-Powered process

More information

B-40/B-41 Modulating Temperature Controller

B-40/B-41 Modulating Temperature Controller INSTALLATION & OPERATING INSTRUCTIONS B-40/B-41 Modulating Temperature Controller For Raytherm Boilers & Water Heaters H2 514-4001 WH2 2100-4001 Catalog No. 5000.70 Effective: 12-21-11 Replaces: NEW P/N

More information

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH CONTROL PANEL INTERFACE USING THE AUTO/OFF/MANUAL SWITCH With the switch set to AUTO, the engine may crank and start at any time without warning. Such automatic starting occurs when utility power source

More information

Instruction Manual PCS-400-XY. Pump Controller. Y=2: 4-20 ma Y=6: 0-10 VDC X=5: 1-5 VDC. 4 Pump Control Relays 1 Alarm Relay 1 Signal Fail

Instruction Manual PCS-400-XY. Pump Controller. Y=2: 4-20 ma Y=6: 0-10 VDC X=5: 1-5 VDC. 4 Pump Control Relays 1 Alarm Relay 1 Signal Fail Manufacturers of Process Controls and Instrumentation Instruction Manual Model: Function: Input: PCS-400-XY Pump Controller X=2: 4-20 ma X=5: 1-5 VDC X=6: 0-10 VDC X=7: Output: Power: 4 Pump Control Relays

More information

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT TRACON MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT TABLE OF CONTENTS GPT 130 Overview... 2 Installation... 3 Power Source and Load Connection... 4 Temperature Sensor Installation... 5 Panel

More information

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM 2 Line, 16 Characters/row LCD Display Temperature Input Range -50 C to +500 C -58 F to + 932 F Enclosure NEMA Type 4X Current Rating 30A max (resistive load only) Ambient Temperature -40 C to + 40 C -40

More information

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features. CONsOlIDATOR 4 & 8 MulTI- C h ANNEl CONTROllERs ConsoliDator 4 Model PD940 ConsoliDator 4 Features Four 4-20 Four 4-20 Outputs ConsoliDator 8 Features Eight 4-20 Two 4-20 Outputs Common Features Four Pulse

More information

99 Washington Street Melrose, MA Phone Toll Free Visit us at

99 Washington Street Melrose, MA Phone Toll Free Visit us at 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 48VTR Product Info Page Instruction Manual English / Español

More information

Tri-Stack Smart System

Tri-Stack Smart System Tri-Stack Smart System TM Notes & Warnings - The protection provided by this equipment may be impaired if it is not used in the manner specified herein. - Ensure all wiring meets applicable national and

More information

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFH24F3XYZ2 Stand-alone with Internal Humidity Sensor

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFH24F3XYZ2 Stand-alone with Internal Humidity Sensor Model TFH24FXYZ2 Stand-alone with Internal Humidity Sensor Description The TFH24FXYZ2 is a fully configurable controller designed specifically for 2 pipe and 4 pipe fan coil applications. No additional

More information

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER 1 VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER 1. INTRODUCTION This manual contains information for the installation and operation and tuning of our Vertex VT10 series self-tuning

More information

Series 5000 Hydrazine Analyzer Model 60002

Series 5000 Hydrazine Analyzer Model 60002 Series 5000 Hydrazine Analyzer Model 60002 T he patented* Series 5000 Hydrazine Analyzer is a continuous-reading instrument using the p-dimethylaminobenzaldehyde method of analysis for colorimetric measurement

More information

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11 Table of Contents 1. OVERVIEW... 3 2. SYSTEM LAYOUT... 4 3. SPECIFICATIONS... 8 3.1 SYSTEM COMPONENTS...9 3.2 PLC INPUTS AND OUTPUTS...9 3.3 FUNCTION KEYS...10 3.4 DEFAULT SET POINTS AND TIMERS...10 4.

More information

Temperature Controllers

Temperature Controllers Model TEC-4100 1/4 DIN Model TEC-4100 1/4 DIN Temperature Controller Ordering Code: Power Input BOX 1 4 = 90-250 VAC 5 = 11-26 VAC / VDC TEC-4100- Configurable for 4 Programmable Outputs and NEMA 4X/IP65

More information

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE / 3 GM20 Digital Ground Continuity Relay For AC Systems Technical Bulletin NAE03230 / 0.20 GM20 Ground continuity monitor For AC systems Description The GM20 monitors the loop resistance of ground conductors

More information

DFM. flow pressure temperature MULTI PARAMETER DIGITAL MASS FLOW METERS. Totalizer. Interface

DFM. flow pressure temperature MULTI PARAMETER DIGITAL MASS FLOW METERS. Totalizer. Interface Multi Parameter flow meters provide accurate data on three different fluid parameters: flow pressure temperature The flow rate can be displayed in volumetric flow or mass flow engineering units for standard

More information

Flow Level Pressure Temperature. Rugged tactile response keys. Try the all new Fluidwell Configurator at:

Flow Level Pressure Temperature. Rugged tactile response keys. Try the all new Fluidwell Configurator at: Fluidwell F-Series Flow Level Pressure Temperature Trend indication Displayed function Clear 0.7 or 1 digits Measurement units for TOTAL Large LCD with backlight option NEMA 4X aluminum or plastic field

More information

Pressure Transducers Ultrahigh-Purity

Pressure Transducers Ultrahigh-Purity www.swagelok.com Pressure Transducers Ultrahigh-Purity PTU Series Single-end, flow-through, and modular surface-mount models Positive pressure ranges to 5000 psi, 400 bar, and 40 MPa; compound pressure

More information

MYRIAD DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL VERSION 3.7

MYRIAD DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL VERSION 3.7 MYRIAD DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL VERSION 3.7 VISIT OUR WEBSITE SIGMACONTROLS.COM MYRIAD DPC MANUAL 013114 1 2 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features

More information

DS 96/48 P. Digital indicator. Short manual 41/33-89 EN Rev. 00 DIM

DS 96/48 P. Digital indicator. Short manual 41/33-89 EN Rev. 00 DIM DS 96/48 P Digital indicator Short manual 41/33-89 EN Rev. 00 A1 A2 DIM E 1 Safety instructions Correct and safe operation of the apparatus calls for expert installation and meticulous maintenance. This

More information

FLOW CONTROLLER TYPE S/601

FLOW CONTROLLER TYPE S/601 Checked Version Release date QA V4.2.6 F1 F2 EN 26.01.2012 Manual FLOW CONTROL FLOW CONTROLLER TYPE S/601 MODELS F1 AND F2 INTRODUCTION Thank you for using the S/601 flow and batch control series. This

More information

Table of Contents SECTION PAGE

Table of Contents SECTION PAGE Table of Contents SECTION PAGE SECTION 1 INTRODUCTION................... 1.1 Description.............................. 1.2 Features................................ 1.3 Models.................................

More information

S/601 Controller Installation Manual

S/601 Controller Installation Manual Checked Version Release date QA V4.6.5 PC1 EN 02.07.2012 2011 S/601 Controller Installation Manual FLOW CONTROL PC1 - Pump controller Introduction Thank you for using the S/601 flow, batch and pump control

More information

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS... SECTION Table of Contents SECTION 1 INTRODUCTION...................... 1.1 Description............................... 1.2 Features................................. 1.3 Models..................................

More information

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08 Beacon 200 Gas Monitor Operator s Manual Part Number: 71-2102RK Released: 6/6/08 Table of Contents Chapter 1: Introduction.................................................3 Overview.............................................................3

More information

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support. AutomationDirect 1/16 DIN Series Technical Support We strive to make our manuals the best in the industry. We rely on your feedback to let us know if we are reaching our goal. If you cannot find the solution

More information

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL GASGUARDIAN 2 3 2-Channel Controller OPERATING & INSTALLATION MANUAL GasGuardian 2 3 Operating and Installation Manual Table of Contents General description.... 3 Installation. 3 Locating the GasGuardian-2..

More information

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL Installation and Operation Manual 2 GG-2 Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified

More information

OVEN INDUSTRIES, INC.

OVEN INDUSTRIES, INC. OVEN INDUSTRIES, INC. OPERATING MANUAL Model 5C7-252 TEMPERATURE CONTROLLER With PLC Inputs Introduction Thank you for purchasing our controller. The Model 5C7-252 is an exceptionally versatile unit and

More information

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements Specifications COMMANDER 150 Universal Process Indicator High visibility 6-digit LED display the clearest view of your process status 0.1% measurement accuracy precise indication of process measurement

More information

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd. F-2000 PC and AO OUTPUT BOARDS INSTRUCTION MANUAL Blue-White R Industries, Ltd. 500 Business Drive Huntington Beach, CA 92649 USA Phone: 714-89-8529 FAX: 714-894-9492 E mail: sales@blue-white.com or techsupport@blue-white.com

More information

CELLTROL II BIOREACTOR CONTROL SYSTEM OPERATIONS MANUAL

CELLTROL II BIOREACTOR CONTROL SYSTEM OPERATIONS MANUAL Operation Manual Celltrol II Bioreactor Control System Page 1 of 33 Table of Contents 1) Introduction... 3 1.1) Scope of Document... 3 1.2) Control System Overview... 3 1.3) Introduction to Celltrol II...

More information

Liquid Level Controller

Liquid Level Controller Liquid Level ontroller Product Bulletin 61-70 Type: HBLT-1/HBLT-1-E Purpose: The HBLT-1 provides remote liquid level management f industrial refrigeration systems. It can be used with the HBLT-A1 HBLT-Wire

More information

EXPERT TRI-STAR. Temperature controller. User s Manual

EXPERT TRI-STAR. Temperature controller. User s Manual Temperature controller r s Manual WARNINGS The warranty can be void if this product is used in a manner not specified by the manufacturer. Every effort has been made to ensure that this manual is complete,

More information

TEMPERATURE CONTROLLER (STANDARD MODEL)

TEMPERATURE CONTROLLER (STANDARD MODEL) OPERATING MANUAL TEMPERATURE CONTROLLER (STANDARD MODEL) 689-0000 689-0005 Barnant Company 28W092 Commercial Avenue Barrington, Illinois U.S.A. 60010-2392 (847) 381-7050 (847) 381-7053 (Fax) 800-637-3739

More information

INSTALLATION INSTRUCTIONS EA SERIES DOOR PROP/EXIT ALARM

INSTALLATION INSTRUCTIONS EA SERIES DOOR PROP/EXIT ALARM 80 Avenida Acaso, amarillo, a. 90 (80) 9-06 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUTIONS EA SERIES DOOR PROP/EXIT ALARM Model EA-SN Model EA-78 Model EA-708 (cylinder not

More information

AO Annunciator Module

AO Annunciator Module General Specifications GS48C43Z01-00E-N AO-543-01 Annunciator Module GENERAL Figure 1 This module has two independent annunciator circuits. The circuits handle fault signals and operator actions (acknowledge,

More information

CTM-530 Series Interface Module

CTM-530 Series Interface Module CTM-530 Series Interface Module Installation and Operation Guide An ISO 9001 Registered Company APPROVED Man-2006 Last modified 1/27/2017 Contains updates included in Firmware v1.2.x2 2016 The Protectowire

More information

ESSEX ENGINEERING CORPORATION

ESSEX ENGINEERING CORPORATION WATER/WASTEWATER TREATMENT CONTROL SYSTEMS AND SUBSYSTEMS 2000 SERIES CONTROL SYSTEMS: 2000 series are for surface mounting inside a control cabinet Model 2024 Electronic Alternator Duplex (two pump) pump

More information

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control O M N I S T A T ELECTRONIC COMMUNICATING THERMOSTAT Installation Manual RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control Document Number 13I00-5 November, 1997 CONTENTS

More information

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422 ºF / º C Rooftop Thermostat Controller Model TRT2422 Description The TRT2422 is a combination controller and thermostat with a built-in scheduler, which is designed for simple and accurate control of single

More information

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual PD154 & PD158 VIGILANTE II ANNUNCIATORS 8 Field Selectable Sequences All Common ISA Sequences 4 or 8-Point (Channel) Monitoring Free Replaceable Message Labels Type 4X, NEMA 4X, IP65 Front Universal Power

More information

Mark 25 Ultrapure Water Conductivity Analyzer

Mark 25 Ultrapure Water Conductivity Analyzer Martek Instruments, Inc. Mark 25 Ultrapure Water Conductivity Analyzer Instruction Manual WARRANTY POLICY Unless otherwise stated, MARTEK INSTRUMENTS, INC. warrants this equipment to be free from defects

More information

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual We manage heat MANUAL Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239

More information

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual We manage heat MANUAL Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239

More information

AS950 PORTABLE SAMPLERS

AS950 PORTABLE SAMPLERS AS950 PORTABLE SAMPLERS Applications Wastewater Collections Industrial Pretreatment Environmental Monitoring Stormwater Sampling has never been this easy. The AS950 Portable Sampler makes programming,

More information

Carbon Monoxide Transmitter

Carbon Monoxide Transmitter Introduction The CO Transmitter uses an electrochemical sensor to monitor the carbon monoxide level and outputs a field-selectable 4-20 ma or voltage signal. The voltage signal may also be set to 0-5 or

More information

S304 and S305 Dust Emission Monitors. User Manual. Distributor

S304 and S305 Dust Emission Monitors. User Manual. Distributor S304 and S305 Dust Emission Monitors User Manual Distributor Version 6.4 30/5/2012 Table of Contents 1. INTRODUCTION... 3 1.1 Safety... 3 1.2 Product overview... 4 1.3 Principle of operation... 4 2. INSTALLATION...

More information

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack Master Catalog 125 Temperature Controls Section A Product/Technical Bulletin Issue Date 1098 MR4PMUHV Electronic Temperature/Defrost Control with Relay Pack The MR series temperature controls are designed

More information

Model 96VTR ¼ DIN Process Controller

Model 96VTR ¼ DIN Process Controller 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 96VTR Product Info Page INSTRUCTION MANUAL Model 96VTR ¼ DIN

More information

Dryer Controller M720

Dryer Controller M720 User Manual Dryer Controller M720 Hardware version 2.00 Software version 2.00 Manual M720 Dryer controller Page 1 of 60 Document history Preliminary version: - Created in April, 2009 Hardware Version 2.00,

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS TT-1343 5/06b INSTALLATION INSTRUCTIONS Original Issue Date: 8/03 Model: Automatic Transfer Switches Equipped with Series 1000 Programmable Controller Market: ATS Subject: Remote Annunciator Kits GM28938-KP1,

More information

4TEMPERATURE CONTROLLER

4TEMPERATURE CONTROLLER Universal Input Output and High Accuracy 0.5 class 250ms TEMPERATURE ONTROLLER RAMP function PID Auto-tuning Universal input /, Reverse/Direct action selectable Remote/Local input selectable Model and

More information

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TRACON MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TABLE OF CONTENTS FPT 130 Overview... 2 Installation... 3 Power Source and Load Connections... 4 Temperature Sensor... 5 External

More information

RC-101 Heat Pump Real Time Pricing System 2 Stage Heat / 1 Stage Cool

RC-101 Heat Pump Real Time Pricing System 2 Stage Heat / 1 Stage Cool O M N I S T A T ELECTRONIC COMMUNICATING THERMOSTAT Installation Manual RC-101 Heat Pump Real Time Pricing System 2 Stage Heat / 1 Stage Cool Document Number 13I00-4 January, 1997 Copyright 1997 Home Automation,

More information

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas User s Manual TIGER S EYE E-Series Mark V Jockey TIGERFLOW Systems, Inc. 4034 Mint Way Dallas, Texas 75237 214-337-8780 www.tigerflow.com TABLE OF CONTENTS Introduction... 4 Sequence of Operation... 5

More information

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER This manual must be left with owner and should be hung on or adjacent to the boiler for reference. US HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER MODELS CHS-85 through CHS-399 APPENDIX A CONTROLLER

More information

T6984 A,D,E Electronic Floating Control Thermostats

T6984 A,D,E Electronic Floating Control Thermostats T6984 A,D,E Electronic Floating Control Thermostats FEATURES PRODUCT DATA PI (proportional and integral) control action provides accurate, stable room temperature control. T6984 models are used with Series

More information

Gas Detection System TOX ALARM DG2000-Garage

Gas Detection System TOX ALARM DG2000-Garage Gas Detection System TOX ALARM DG2000-Garage Gas Detection System 32 independent programmable channels 2 programmable alarm levels for each gas = up to 6 for each channel LCD alphanumeric display of gas

More information

Rev Pulse Modulating Anti- Sweat Control (PMAC II) Installation and Operation Manual

Rev Pulse Modulating Anti- Sweat Control (PMAC II) Installation and Operation Manual 026-1501 Rev 5 3-20-03 Pulse Modulating Anti- Sweat Control (PMAC II) Installation and Operation Manual 1640 Airport Road, Suite 104 Kennesaw, GA 31044 Phone: (770) 425-2724 Fax: (770) 425-9319 ALL RIGHTS

More information

Nov 08 PRODUCT SPECIFICATION SHEET

Nov 08 PRODUCT SPECIFICATION SHEET Honeywell UDC1200 and UDC1700 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS 51-52-03-35 Nov 08 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1200 & UDC1700 are microprocessor-based 1/16 DIN and 1/8 DIN

More information

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1- DPR-45 User Manual V-2.0 (2..206) DPR-45 TEMPERATURE PROTECTION RELAY PT00 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT 9-50VDC SUPPLY DESCRIPTION DPR-45 is a precision unit designed for the temperature

More information

4 & 8-POINT ANNUNCIATORS Instruction Manual

4 & 8-POINT ANNUNCIATORS Instruction Manual 4 & 8-POINT ANNUNCIATORS Instruction Manual 8 Field Selectable Sequences All Common ISA Sequences 4 or 8-Point (Channel) Monitoring Free Replaceable Message Labels Type 4X, NEMA 4X, IP65 Front Universal

More information

Modus Model DA General Eastern Low Differential Pressure Alarm Controller

Modus Model DA General Eastern Low Differential Pressure Alarm Controller GE Sensing & Inspection Technologies Modus Model DA General Eastern Low Differential Alarm Controller The Modus Model DA is a controller designed for the monitoring of low differential pressures. It combines

More information

Series A3 and A4 Differential Pressure Controller

Series A3 and A4 Differential Pressure Controller Bulletin 102-0 Installation and Operation Series A3 and A4 Differential Pressure Controller Sensocon, Inc. Phone: (863) 248-2800 Fax: (863) 248-2798 www.sensocon.com 1. Introduction 1.1. Model Number Configuration

More information

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual From urgent alarms to routine messages, the PD141AFO VIGILANTE handles all types of operational messages with simplicity and economy. The VIGILANTE

More information

Application Manual Loop Water Controller

Application Manual Loop Water Controller Application Manual Loop Water Controller AM - LWC TABLE OF CONTENTS LIST OF FIGURES ii iii 1.0 SAFETY CONSIDERATION 1 1.1 Installation Recommendations 1 2.0 GENERAL DESCRIPTION 2 2.1 General Introduction

More information

2012 Toolbar & NH3 Operators Manual

2012 Toolbar & NH3 Operators Manual 2012 Toolbar & NH3 Operators Manual P/N 320379 Amity Technology, LLC 2800 7th Avenue North Fargo, ND 58102 (701) 232-4199 www.amitytech.com This Page Left Intentionally Blank Page 2 2012 Toolbar/NH3 Manual

More information

User Manual. Dryer Controller M720

User Manual. Dryer Controller M720 User Manual Dryer Controller M720 Hardware version 1.00 Software version 1.00 Preliminary version Manual M720 Dryer controller Page 1 of 42 Document history Preliminary version: - Created in April, 2009

More information

RE-PR3-E-27 3-Phase Panel Mount 27kW

RE-PR3-E-27 3-Phase Panel Mount 27kW Page 1 of 6 RE-PR3-E-27 3-Phase Panel Mount 27kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting

More information

Pump-Down Controller MODEL 4052

Pump-Down Controller MODEL 4052 Pump-Down Controller 4-20mA Input/Scalable Output Seal Fail Monitoring Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters RS-485/Modbus Communications DESCRIPTION The Model 4052 Pump-Down

More information

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide System Reset Trou ble Silence Ala rm Silence Manual Ala rm ENTER NO YES Letters Numb ers Keyword Radionics System Reset Trouble Silence Alarm Silence Manual Alarm ENTER NO YES Le ters Numbers Keyw ord

More information

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times! USER GUIDE English IMPORTANT PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times! Failure to comply may result in the Detector initiating a Fire or Fault signal. Contents

More information

DIGITAL METERS Large Display Temperature Meters Instruction Manual

DIGITAL METERS Large Display Temperature Meters Instruction Manual DIGITAL METERS Large Display Temperature Meters PD755 PD756 PD757 Handles Thermocouple & RTD Inputs with Simplicity J, K, T, E, R, & S Thermocouples 100 Ω Platinum RTD (0.00385 or 0.00392 curve) Large

More information

EVO192 v3.0 Fire and Burglary What s New

EVO192 v3.0 Fire and Burglary What s New EVO192 v3.0 Fire and Burglary What s New Compatibility: EVO192 v3.0 TM50 v1.31 K641 v2.41 Overview: CP-01 Compliancy Wiring Diagram The following sections/options have been added to the EVO192 panel. They

More information

2-wire Passive Intelligent Loop (LED) Display Meter

2-wire Passive Intelligent Loop (LED) Display Meter Features Two-wire passive intelligent loop current (LED) digital meter 2-wire Passive Intelligent Loop (LED) Display Meter Embedded 2-wire Passive Programmable 4-20mA Loop (Four Digits LED) Display Meter

More information

F4 Process Controller Installation and Operation Guide

F4 Process Controller Installation and Operation Guide F4 Process Controller Installation and Operation Guide 1.Introduction 1.1.Highlight Features Space saving, only 55mm panel depth required Higher sampling rate (1mS) results in better control performance

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit ABB MEASUREMENT & ANALYTICS DATA SHEET C50 1/16 DIN controller / alarm unit 2 C50 1/16 DI N CON TROLL ER / AL ARM U NIT DS/C 50-E N RE V. M Measurement made easy C50 the 1/16 DIN controller to suit your

More information

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation The most user friendly Contents Section 1 Overview of System 1.1 Kit Contents 1.2 Tools Required 1.3 System Features Security Alarm System L S 4 0 0 Section 2 Planning your Installation 2.1 Location of

More information

AS950 REFRIGERATED SAMPLERS

AS950 REFRIGERATED SAMPLERS AS950 REFRIGERATED SAMPLERS Applications Wastewater Collections Industrial Pretreatment Environmental Monitoring Stormwater Sampling has never been this easy. The AS950 Refrigerated Sampler makes programming,

More information

Multiple Battery Cabinets Dual-Lite TRN. External Maintenance Switch Configuration Options. External Maintenance Switch Options

Multiple Battery Cabinets Dual-Lite TRN. External Maintenance Switch Configuration Options. External Maintenance Switch Options Table 4 External Maintenance Switch Configuration Options External Maintenance Switch Options Installed with Interlock Option Option Auxiliary Contact Status open = On Test position or Maintenance position,

More information

Digital Heater Element Burnout Detector K8AC-H

Digital Heater Element Burnout Detector K8AC-H Digital Heater Element Burnout Detector K8AC-H A high-precision Heater Element Burnout Detector compatible with a wide-range of heater control methods. Push-in terminals reduce the workload. *1 Scaling

More information

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE D (OPERATION) INITIATE A DYNAMIC BATTERY TEST The system tests the back-up battery once every 24 hours. The owner can initiate a dynamic battery test at any time with the following codes while the system

More information

JDDT1 - Single Stage Digital Thermostat

JDDT1 - Single Stage Digital Thermostat JDDT1 - Single Stage Digital Thermostat CAUTION NOTICE: The thermostat must be installed by authorized professionals. It should be located in a place free of vibrations, impacts, and corrosive gases. SET

More information

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input User Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with

More information