1 technical manual

2

3 ENGLISH ESPÑOL CONTENTS 1.- INTRODUCTION TECHNICL DT 2.- FLOOR TRUNKING. General Technical Characteristics B. dditional Technical Tests C. Usable Sections and Maximum Cable Diameters Table 1. Usable Sections and Maximum Floor Trunking Diameters 3.- TRUNKS FOR DISTRIBUTION (CD) ND MECHNISMS (CM) 3.1. INSULTING CD/CM TRUNKS. General Technical Characteristics B. dditional Technical Tests C. Usable Sections Table 2. Usable sections of CD Trunks Table 3. Usable sections of insulating CM Trunks 3.2. LUMINIUM CM TRUNKS. General Technical Characteristics B. Usable Sections Table 4. Usable Sections of luminium CM Trunks 4.- MECHNISM HOLDER UNIT. General Technical Characteristics B. dditional Technical Tests 5.- MULTIFUNCTION BOXES 5.1. SURFCE BOXES, BOXES TO BE BUILT IN ON SITE, ND BOXES TO BE BUILT INTO PLSTER WLLS. General Technical Characteristics B. dditional Technical Tests 5.2. BBILON TOWER. General Technical Characteristics B. dditional Technical Tests 6.- TECHNICL FLOORS. General Technical Characteristics B. Compliance with existing Standards C. dditional Technical Tests D. Sizes 7.- OFFICE SYSTEM. General Technical Characteristics B. ssembly diagrams 49 49

4 8.- MECHNISMS V 10/16 SOCKETS 8.2. DOUBLE 250V SOCKETS 8.3. CONTROL MECHNISMS (BREKERS ND SWITCHES) 8.4. RJ11 ND RJ12 TELEPHONE SOCKETS 8.5. RJ45 CONNECTORS 8.6. MGNETOTHERML ND DIFFERENTIL SWITCHES 8.7. TELEVISION SOCKETS 9.- DDITIONL TECHNICL INFORMTION 50

5 TECHNICL DT 1. INTRODUCTION TECHNICL DT Safety in electrical installations is one of EMS s priorities when developing products for manufacture. For this reason, all these products undergo an exhaustive control to check compliance with all applicable standards and regulations, complemented by subsequent quality controls in all production phases. This Technical Data section refers continuously to the tests applied to guarantee safe installations. Mention is also made of the legislation governing these products, with reference always made to the applicable standard. Furthermore, EMS provides the installation instructions needed to guarantee the safety of the installation, and not just on the basis of its own standards as a manufacturer, but also in accordance with the applicable legislation and standards. ENGLISH Moreover, all the products in this catalogue fall within the scope of the European Directive BT 73/23 EEC for low-voltage installations, and the products bear the corresponding EC mark and the marks applicable to it as required by this Directive and by the relevant legislation. EMS participates in the following national harmonisation work groups which are in charge of drafting the standards applicable to the products in this catalogue: EN/CTN 201/SC23/WG1: Trunks EN/CTN 201/SC23/WG7: Fire behaviour in electrical wiring systems EN/CTN 201/SC23B/WG5: Junction boxes and electrical mechanisms EN/CTN 201/SC89: Fire hazards ll under the strictest possible Quality and Environmental Management System, pioneered by EMS, as substantiated by the SGI certification (Integrated Quality Management System ISO 9001, and Environment 14001) for all its facilities, being the first company in the electrical sector to obtain this certification. Finally, mention must be made of the company s technical media, with one of the most important laboratories in the sector, that respond to the major and continuous investments made by EMS in Research, Development and Innovation. 51

6 2. FLOOR TRUNKING. GENERL TECHNICL CHRCTERISTICS MTERIL M1 rigid PVC Technical characteristics and tests included in the dditional Technical Tests paragraph COLOUR RL 7030 Grey COMPLINCE WITH THE STNDRD EN :2005 Cable trunking systems and cable ducting systems for electrical installations. Part 1: General requirements. OPERTING TEMPERTURE: -15ºC to +60ºC MIN. STORGE ND TRNSPORT TEMPERTURE: -45ºC COVER RETENTION OPENED ONLY WITH THE HELP OF TOOL Dossier no of the L.G..I. IMPCT STRENGTH 2 J (MEDIUM) ELECTRICL PROPERTIES INSULTING FLME SPRED RESISTNCE NON-FLME SPREDING Dossier no of the L.G..I. GLOW WIRE TEST DEGREE OF SEVERITY 960ºC (according to UNE EN :2001) HET RESISTNCE TEST STISFCTORY T 70ºC PROTECTION FROM SOLID ND LIQUID PENETRTION (*) Floor trunk PC-1250: Degree IP64 Floor trunks PC-1875 and PC-25100: Degree IP65 ccording to UNE 20324:93 (EN 60529) Report no. S of the IMME (*) pplicable only to the closure of the Cover - Floor Trunk section 52

7 TECHNICL DT DECLRTION OF CONFORMITY MRKING. COMPLINCE WITH THE EUROPEN DIRECTIVE BT 73/23/EEC COMPLINCE WITH THE STNDRD EN :2005, WITH CLSSIFICTION: NON-METLLIC. IMPCT STRENGTH 2 J (MEDIUM) TEMPERTURE 121 (*) NON-FLME SPREDING. NO ELECTRICL CONTINUITY. WITH ELECTRICL INSULTION. IP65 (PC-1875 and PC-25100) and IP64 (PC-1250) CCESS COVER THT CN ONLY BE OPENED WITH TOOLS ENGLISH (*) Code 121: 1: Minimum storage and transport temperature (-45ºC) 2: Minimum installation and application temperature (-15ºC) 1: Maximum installation and application temperature (+60ºC) B. DDITIONL TECHNICL TESTS FIRE RECTION TEST i (flammability index) = 0 s (flame spread index) = 0 h (maximum flame length index) = 0 c combustion index) < 1 Classification: M1 ccording to UNE ccording to dossier no of the L.G..I. PLSTIC MTERIL FLMMBILITY TEST Classification: Degree 94-V0 ccording to UL Dossier no / of the IMPLS GLOW WIRE TEST Result of the test: Satisfactory. Degree of severity: 960ºC ccording to UNE-EN :02 Dossier no / of the IMPLS SELF-EXTINGUISHING TEST Classification: FH1 Extinguishing time: 0 sec. ccording to UNE Dossier no of the L.G..I.I. 53

8 FIRE RECTION TEST FOR BUILDING MTERILS ND STRUCTURES Classification: Class 1 Method for the classification of flame spread ccording to BS 476 part 7: 1997 Dossier no of the L.G..I. RESISTNCE TO BNORML HET Result of the test: Satisfactory (T 500ºC) Dossier no of the L.G..I. CORROSIVENESS OF THE GSES EMITTED DURING THE COMBUSTION OF THE PVC Result of the test: ph > 2. Conductivity < 2750 µs/cm ccording to UNE (part 2) Report no. T 0373/98 of the IMPLS DETERMINTION OF CO ND HCl IN THE COMBUSTION OF THE PVC Result of the test: HCl: 262 mg/(g. of sample) CO: 47 mg/(g of sample) ccording to NF C Dossier of the L.G..I. DETERMINTION OF THE LIMITING OXYGEN INDEX (L.O.I.) Result of the test: Limiting oxygen index (concentration %) = Interval between 58 and 59. ccording to UNE EN ISO :01 TEST FOR THE DETERMINTION OF SMOKE OPCITY DURING COMBUSTION Result of the test: Maximum specific optical density:dm= 395 Value of darkening due to smoke V0F4=182.2 ccording to NF X :86 (STM E ) Dossier of the L.G..I. CLSSIFICTION OF FIRE BEHVIOUR: FIRE RECTION, OPCITY ND SMOKE TOXICITY Classification: I1 F4 ccording to NF F TEST FOR THE DETERMINTION OF THE DIELECTRIC STRENGTH OF PERFORTION OF PVC Result of the test: >Dielectric strength 20 kv/mm ccording to UNE (part 1) Dossier no of the L.G..I. TRNSVERSL ND SURFCE RESISTIVITY DETERMINTION TEST Result of the test: ccording to UNE 21303:83 Dossier no of the L.G..I. PROTECTION FROM MECHNICL DMGE Result of the test: Classification Degree IK-09 ccording to UNE EN 50102:1995 Surface resistivity (s): > 1.88 x 1015 W Transversal resistivity (r): > 3.25 x 1014 W cm 54

9 TECHNICL DT C. USBLE SECTIONS ND MXIMUM CBLE DIMETERS MODEL USBLE SECTIONS (mm 2 ) B TOTL MXIMUM CBLE DIMETERS (mm) B PC PC ENGLISH PC TRUNKS FOR DISTRIBUTION (CD) ND MECHNISMS (CM) INSULTING CD/CM TRUNKS. GENERL TECHNICL CHRCTERISTICS MTERIL M1 rigid PVC Technical characteristics and tests included in the dditional Technical Tests paragraph COLOUR RL 9003 White COMPLINCE WITH THE STNDRD EN :2005 Cable trunking systems and cable ducting systems for electrical installations. Part 1: General requirements. OPERTING TEMPERTURE -15ºC to +60ºC MIN. STORGE ND TRNSPORT TEMPERTURE: -45ºC COVER RETENTION OPENED ONLY WITH THE HELP OF TOOL IMPCT STRENGTH 2 J (MEDIUM) 55

10 ELECTRICL PROPERTIES: INSULTING FLME SPRED RESISTNCE NON-FLME SPREDING Dossier no of the L.G..I. GLOW WIRE TEST DEGREE OF SEVERITY 960ºC (according to UNE EN :2001) HET RESISTNCE TEST STISFCTORY T 70ºC PROTECTION FROM SOLID ND LIQUID PENETRTION (*) Classification - CD and CM Trunks: Degree IP55 ccording to UNE 20324:93 (EN 60529) (*) pplicable only to the closure of the Cover - Trunk section DECLRTION OF CONFORMITY MRKING. COMPLINCE WITH THE EUROPEN DIRECTIVE BT 73/23/EEC COMPLINCE WITH THE STNDRD EN :2005, WITH CLSSIFICTION: NON-METLLIC. IMPCT STRENGTH 2 J (MEDIUM) TEMPERTURE 121 (*) NON-FLME SPREDING. NO ELECTRICL CONTINUITY. WITH ELECTRICL INSULTION. IP55 CCESS COVER THT CN ONLY BE OPENED WITH TOOLS (*) Code 121: 1: Minimum storage and transport temperature (-45ºC) 2: Minimum installation and application temperature (-15ºC) 1: Maximum installation and application temperature (+60ºC) B. DDITIONL TECHNICL TESTS FIRE RECTION TEST Classification: M1 ccording to UNE VERTICL FLMMBILITY TEST Classification: Degree V0 ccording to UNE EN and UL HORIZONTL FLMMBILITY TEST Classification: Degree HB40 ccording to UNE EN

11 TECHNICL DT GLOW WIRE TEST Result of the test: Satisfactory. Degree of severity: 960ºC ccording to UNE EN PROTECTION FROM SOLID ND LIQUID PENETRTION Result of the test: CD and CM Trunks: Degree IP55 pplicable only to the closure of the Cover - Trunk section ccording to UNE 20324:93 (EN 60529) PROTECTION FROM MECHNICL DMGE Result of the test: Classification Degree IK-09 ccording to UNE EN 50102:19955 ENGLISH C. USBLE SECTIONS MODEL USBLE SECTIONS (mm 2 ) SECCIONES ÚTILES ENTRE TBIQUES (mm 2 ) B C D E CD CD /2 B 900/900 B CD B B B C B C B C CD /2 B 1.160/1.160 B CD B B B C B C B C CD B B B C B C B C CD B B B C B C B C

12 MODEL TOTL USBLE SECTION (mm 2 ) USBLE SECTIONS BETWEEN WLLS (mm 2 ) B C D E CD (*) B C D E B C D E B C D E B C D E CD (*) B C D E B C D E B C D E B C D E CD / B 3.465/3.465 B C D x 8 B C D B C D Table 2. Usable sections of CD Trunks. (*) In the distribution trunks CD and CD-60200, the sections are defined for the maximum number of conductors, the other combinations of 2, 3, or 4 trunks may be set by differences as from the maximum section. 58

13 TECHNICL DT MODEL TOTL USBLE SECTION (mm 2 ) USBLE SECTIONS BETWEEN WLLSV (mm 2 ) B C D E CM B B B C B C B C ENGLISH CM B B B C B C B C CM (*) / / B C D E x 8 B C D E B C D E B C D E Table 3. Usable Sections of insulating CM Trunks (*) In the trunk CM-60200/2x80, the sections are defined for the maximum number of conductors; the other combinations of 2, 3, 4, or 5 trunks may be set by differences as from the maximum section LUMINIUM CM TRUNKS - GENERL TECHNICL CHRCTERISTICS MTERIL COLOR Satin-finish anodised aluminium RL 9006 luminium COMPLINCE WITH THE STNDRD EN :2005 Cable trunking systems and cable ducting systems for electrical installations. Part 1: General requirements. 59

14 OPERTING TEMPERTURE: -25ºC to +120ºC MIN. STORGE ND TRNSPORT TEMPERTURE: -45ºC COVER RETENTION OPENED ONLY WITH THE HELP OF TOOL IMPCT STRENGTH: 2 J (MEDIUM) ELECTRICL PROPERTIES: WITHOUT ELECTRICL INSULTION FLME SPRED RESISTNCE: NON-FLME SPREDING PROTECTION FROM SOLID ND LIQUID PENETRTION (*) Degree IP55 ccording to UNE 20324:93 (EN 60529) (*) pplicable only to the closure of the Cover - Trunk section DECLRTION OF CONFORMITY: EEC EC MRKING. COMPLINCE WITH THE EUROPEN DIRECTIVE BT 73/23/ COMPLINCE WITH THE STNDRD EN :2005, WITH CLSSIFICTION: METLLIC IMPCT STRENGTH 2 J (MEDIUM) TEMPERTURE 114 (*) NON-FLME SPREDING. WITH ELECTRICL CONTINUITY. WITHOUT ELECTRICL INSULTION. IP55 CCESS COVER THT CN ONLY BE OPENED WITH TOOLS (*) Code 114: 1: Minimum storage and transport temperature (-45ºC) 1: Minimum installation and application temperature (-25ºC) 4: Maximum installation and application temperature (+120ºC) 60

15 TECHNICL DT MODEL USBLE SECTIONS (mm 2 ) B TOTL CM CM ENGLISH CM (*) / 2 x Table 4. Usable Sections of luminium CM Trunks 4. MECHNISM HOLDER UNIT. GENERL CHRCTERISTICS Material Colores Self-extinguishing and UV-stabilised BS. RL 9003 White Colour frames RL 1003 Yellow RL 3020 Red RL 5015 Blue RL 6032 Green PTENTED SYSTEM Compliance with the Standard EN :2005 Cable trunking systems and cable ducting systems for electrical installations. Part 1: General requirements. The CD and CM series mechanism holders for distribution trunks and mechanisms comply with existing national and international standards. The aforementioned mechanism holders have ENOR certification (N mark) regarding the standards: UNE 20315: Socket bases and plugs for household and similar use UNE EN (EN : 1999): Switches for fixed, household and similar electrical installations. Part 1: General requirements. UNE EN /1: Switches for fixed, household and similar electrical installations. Part 1: General requirements. N MRK. CCESSORIES FOR SSEMBLING SWITCHES ND BSES: ENOR Product Certificate no. 030/

16 DECLRCIÓN DE CONFORMIDD EC MRKING. COMPLINCE WITH THE EUROPEN DIRECTIVE BT 73/23/ EEC. COMPLINCE WITH THE STNDRD EN :2005, WITH CLSSIFICTION: NON-METLLIC IMPCT STRENGTH DURING INSTLLTION ND PPLICTION: MEDIUM STORGE, TRNSPORT ND INSTLLTION TEMPERTURES: CLSSIFICTION 121 (*) (*) Code 121: 1: Minimum storage and transport temperature (-45ºC) 2: Minimum installation and application temperature (-15ºC) 1: Maximum installation and application temperature (+60ºC)) NON-FLME SPREDING NO ELECTRICL CONTINUITY. WITH ELECTRICL INSULTION. WITH CCESS COVER THT CN ONLY BE OPENED WITH TOOLS B. DDITIONL TECHNICL TESTS GLOW WIRE TEST Result of the test: Satisfactory. Degree of severity: 650ºC ccording to UNE EN PROTECTION FROM MECHNICL DMGE Result of the test: Passed, according to UNE EN BNORML HET RESISTNCE Result of the test: Satisfactory at 70ºC according to UNE EN GING RESISTNCE TEST Result of the test: Satisfactory at 70ºC according to UNE EN MOISTURE RESISTNCE Result of the test: Passed. Moisture range: [91%, 95%] according to UNE EN EXTERNL LOD TEST Result: Passed. Tested to 1.5 times the maximum breaking load according to UNE EN

17 TECHNICL DT 5. MULTIFUNCTION BOXES 5.1. SURFCE BOXES, BOXES TO BE BUILT IN ON SITE, ND BOXES TO BE BUILT INTO PLSTER WLLS. GENERL CHRCTERISTICS ENGLISH MTERIL COLOR Self-extinguishing and UV-stabilised BS RL 9003 White The system may be adapted to allow for easy expansion and/or reduction, and so expansion modules are supplied Tools and fixing screws are not necessary to assemble all their components. The box may be serviced on any of its four sides. It can be mounted both horizontally and vertically to suit the mechanisms orientation, according to installation requirements. SURFCE BOXES: The mains covers allow access to the following trunks: MC 1625 MC 1640 MC 1640/2 MC 2540 MC 2540/2 BUILT-IN BOXES: They may be serviced using trunks of up to Æ20 mm on one side and up to Æ16 mm on the other. PTENTED SYSTEM They are specially designed to enable the frames to be removed together, without the need to dismantle them one by one. They enable straight and curved plugs to be connected, without interference between them. Compliance with the UNE 20451:1997. Boxes and enclosures for electrical accessories for household and similar fixed electrical installations. Compliance with the IEC :2002. Boxes and enclosures for electrical accessories for household and similar fixed electrical installations - Part 1: General requirements. Compliance with existing national and international standards: UNE 20451: 97: General requirements for accessory enclosures for household and similar fixed electrical installations 63

18 IEC : Boxes and enclosures for electrical accessories for household and similar fixed electrical installations CB Certificate from the IEC (International Electrotechnical Commission), for international standard IEC : ENOR Product certification (N Mark): BOXES FOR SWITCHES ND BSES: ENOR product certificate no. 030/ EMS was the first Spanish company to obtain the N certification with magnetothermal protection DECLRTION OF CONFORMITY EC MRKING. COMPLINCE WITH THE EUROPEN DIRECTIVE BT 73/23/ EEC. Compliance with the standards UNE 20451:1997 and IEC , with classification CCORDING TO UNE TYPE OF MTERIL Insulating material METHOD OF INSTLLTION SURFCE BOXES: Surface-mounted BUILT-IN BOXES: Semi built-in METHOD OF SSEMBLY SURFCE BOXES: Surface enclosures on non-combustible walls and ceilings BUILT-IN BOXES: Enclosures on non-combustible walls, ceilings and hollows. TEMPERTURE INTERVL DURING INSTLLTION ºC to +60ºC MXIMUM TEMPERTURE DURING THE CONSTRUCTION OF THE WORK ºC DEGREE OF PROTECTION FROM DIRECT CONTCT ND HRMFUL PENETR- TION OF SOLID OBJECTS ND WTER 5.6. IP-3X - Surface Boxes with Magnetothermal switch IP-4X - Surface Boxes without Magnetothermal switch IP-3X Built-in Boxes THE EXISTENCE OF SUSPENSION MEDI Without suspension media CCORDING TO IEC TYPE OF MTERIL 7.1. Insulating METHOD OF INSTLLTION SURFCE-MOUNTED - Non-combustible Walls / Furniture BUILT-IN SSEMBLY (Boxes built-in on site) Non-combustible walls, non-combustible ceilings or non-combustible floors BUILT-IN SSEMBLY (Boxes built into plaster walls) Hollow walls, hollow ceilings, hollow floors or furniture SITE - Suitable for all types of installation, except in concrete. TIPO DE ENTRDS Con entradas para tubos lisos o corrugados Con entradas para otros tipos de conductores / cables o conductos. 64

19 TECHNICL DT TYPE OF INLETS With inlets for smooth or corrugated tubes With inlets for other types of conductors/cables or trunks. FIXING MEDI SURFCE BOXES: With cable retention BUILT-IN BOXES: Without fixing system MXIMUM ND MINIMUM TEMPERTURES DURING INSTLLTION ºC to +60ºC MXIMUM TEMPERTURE DURING THE CSTING PROCESS 7.6. Not applicable ENGLISH B. DDITIONL TECHNICL TESTS PROTECTION FROM ELECTRIC SHOCKS Result of the test: Satisfactory ccording to IEC :2002. ccording to dossier no. 030/ of the CEIS CONSTRUCTION PROVISIONS Result of the test: Satisfactory ccording to IEC :2002 ccording to dossier no. 030/ of the CEIS RESISTNCE TO GING, PROTECTION FROM THE ENTRY OF SOLID OBJECTS ND FROM THE HRMFUL PENETRTION OF WTER Result of the test: Satisfactory ccording to IEC :2002 ccording to dossier no. 030/ of the CEIS RESISTNCE OF INSULTION ND VOLTGE STRESS Result of the test: Satisfactory ccording to IEC :2002 ccording to dossier no. 030/ of the CEIS MECHNICL STRESS Result of the test: Satisfactory ccording to IEC :2002 ccording to dossier no. 030/ of the CEIS HET RESISTNCE Result of the test: Satisfactory ccording to IEC :2002 ccording to dossier no. 030/ of the CEIS RESISTNCE OF THE INSULTING MTERIL TO BNORML HET ND FIRE Result of the test: Satisfactory ccording to IEC :2002 ccording to dossier no. 030/ of the CEIS 65

20 PROTECTION FROM ELECTRIC SHOCKS Result: Satisfactory. Degree of Protection IP 30 (with magnetothermal switch) Degree of Protection IP 40 (without magnetothermal switch) ccording to UNE ccording to dossier no. 030/ of the CEIS CONSTRUCTION PROVISIONS Result: The enclosures have a suitable mechanical resistance. ccording to UNE ccording to dossier no. 030/ of the CEIS RESISTNCE TO GING Result: fter the test, the samples showed no deterioration. ccording to UNE ccording to dossier no. 030/ of the CEIS 5.2. BBILON TOWER. GENERL CHRCTERISTICS MTERIL Plastic parts: Self-extinguishing BS vailable in the following colours: RL 7026 Grey RL 3020 Red RL 6032 Green RL 1003 Yellow RL 5015 Blue PTENTED SYSTEM luminium: luminium injected with epoxy coating. Its functional design offers advantages in the installation, such as saving the skirting board in wall installations, opening the mechanism holder by means of a hinge system, thus providing easy access to the Tower s interior, as well as allowing for a wide range of assembly combinations, etc. The Babilon Tower may be directly accessed with the PC 1250 Floor Trunk, or laterally by means of the corresponding accessories, with PC 1875 and PC The Tower may be accessed through the MC1616, MC1625 and MC1640 minitrunks by means of an optional accessory (minitrunk coupling) inserted into the back of the Tower 66

21 TECHNICL DT STNDRDS It is suitable and safe for the purpose it has been designed for, and it complies with the following standards: UNE-EN :1997 Cable trunking systems and cable ducting systems for electrical installations. Part 1: General requirements. ccording to Standard EN :1997 the Babilon Mechanism Tower is classified as:.2. SCC/SCNC type for floor installations Type: Service Unit For: pparatus ssembly: On the floor surface. ENGLISH SWITCHES UNE-EN :1996 Switches for household and similar fixed electrical installations. Part 1: General prescriptions. SERVICE POLES PrEN CBLE TRUNKING ND DUCTING SYSTEMS FOR ELECTRICL INSTLLTIONS Part 2.4: Particular requirements for Service poles B. DDITIONL TECHNICL TESTS Test for protection from the penetration of solid bodies, according to standard UNE 20324:93. Result: IP-4X. Test for impact for installation and application: Pr EN : Section Shock resistance: Medium. Impact test according to UNE EN 50102: 96. Result: IK-07. Glow wire test according to UNE EN Degree of severity: 650ºC Heat resistance (Imprint test / ir ventilation heater) according to EN : Section Test satisfactory (70 ºC 6 2 ºC). 6.- TECHNICL FLOORS. GENERL CHRCTERISTICS MTERILES Insulating materials: Metallic materials: Self-extinguishing Polyamide 6 (ST Boxes) Self-extinguishing PC+BS (CP Boxes) Galvanised steel plate SZ (CPM Boxes) 67

22 COLOR RL 9004 Black dvantages The most outstanding advantages of this Technical Floor range or system, and which give it a special edge on other products currently on the market are: Regarding the ST-2 boxes 1.s with the ST-4, ST-6 and ST-8, the mechanism holder frames can be removed in order to assemble the mechanisms. 2.The ST-2 mechanism holder box enables us to connect both curved and straight plugs, with the same connection and assembly characteristics. 3.The latch regulation range enables us to cover thicknesses of between 8 and 47 mm, without the need to exchange their position. 4.Safety cover system with multiple independent openings that facilitate connection at the work station. REGRDING THE ST-4, ST-6 ND ST-8 BOXES 1. Their carefully studied V-shaped design allows for maximum use of the interior space, whilst at the same time reducing the total height of the box. In this way we may place any type of plug (straight or curved) inside without the need to increase the height, and we may also safely close the cover. 2.The boxes mechanism holders may be removed in one block in order to facilitate connection. 3.The cover may be placed in 2 positions (tools are required) 4.Simple removal of the cover using a tool, to be placed in the required direction. 5.Easy opening system. 6.Device for placing magnetothermal switches (only ST-6). The box height does not have to be increased for their placement. 7.The box has compartments for flanges and connection leads 8.Guide for cable outlet and retention. 68

23 TECHNICL DT IMPORTNT FETURES The ST-4, ST-6 and ST-8 boxes have certain important features that must be known: 1. The latch has 2 assembly positions according to floor thickness. In order to cover all floor thicknesses, the latch has 2 positions: the normal position set by the manufacturer has a thickness interval of 12 to 35 mm, and the other position is for narrow thicknesses of 3 to 25 mm. ENGLISH Normal position set by manufacturer WIDE THICKNESSES NRROW THICKNESSES 2. The Schuko mechanism has a set position. It is important to bear in mind that the correct placement of the mechanism is essential for a correct interior distribution of plugs and cables. 3. The hollow for the carpet, parquet, tiles... is 5 mm deep. 4. The BCM mechanism cover base has inlets for tubes of between ø18 and ø In order to install boxes, the false floor must be equal to or higher than 75 mm. The standard height on the market is 80 mm 7. Sizes for the hollow where the boxes are to be inserted. ST-2: ST-4: ST-6: ST-8: 2 taladros de Ø80 cuyos centros están separados 60 mm. 164x182 cm 164x246 cm. 182x347 cm. 69

24 Below the Surface Metal junction boxes CPM (only applicable to ST-4, ST-6 and ST-8) The EMS metal junction boxes offer an innovative and functional system. Their special design enables us to guarantee that the system is the easiest and safest on the market. The metal junction boxes stand out for the following: 1. Their regulation and levelling system is completely new and can be carried out with just 1 llen key, without the slightest effort. The metal Junction Boxes (CPM) have a regulation range of between 75 and 110 mm. This regulation option is included out of the need to level all the premises boxes in the installation below the surface, so that the concrete is at the same height at all points. 2. With the EMS below surface system, there is no need to increase the minimum height, as 75 mm enable us to cover all types of plugs and sockets, including magnetothermals. In other systems on the market, if you attempt to place straight or magnetothermal plugs, you must increase the height (in some cases up to 100 mm.) in order to have sufficient space inside the connection boxes. This new installation concept enables a saving of concrete of up to 25% in some cases, with all the advantages that this entails: financial and the fact that it is not necessary to increase the premises admissible load. 3. The safety requirement for the installer and the user has been a priority during the metal junction boxes design stage. These boxes have no cutting edges or facets, which greatly facilitate their use and operation. Following this principle, the unit is held with metal zeds that are subsequently removed, preventing any possible harm to the installer during the electrical cabling process. 4. Electrical continuity all over the box through four points (corners). Earthing device (Cable minimum 4 mm2) 5. The boxes have bypass boards for trunk, tube and those without holes that may be easily removed from the box to be serviced or replaced. 6. The boxes have alignment marks that enable us to position several boxes in perfect order. 70

25 TECHNICL DT Plastic junction boxes CP (only applicable to ST-2, ST-4 and ST-6) Important: This application is not possible with the ST-8 model. Should you require an installation below the surface with ST-8 boxes, a CPM metal box should be used. Plastic junction boxes have the same function as metal boxes but they are used for small installations where cost is an important factor. They also allow for greater freedom of movement in the installation as they are inter-connected with tubes. The CP junction boxes stand out for the following: 1. s with the CPM boxes, the CP boxes have a chipboard to prevent material from falling inside. ENGLISH 2. ccess to the box has been prepared for tubes of Ø18 and Ø30. With a pre-punched access, we can insert tubes of these diameters inside the box. 3. The regulation and fixing system for the CP-4 and CP-6 boxes is carried out using screws: 4 screws increase the height and another 4 secure the box. 4. The CP-2 has the same regulation-fixing system but only 2 screws are used for fixing. The tube access is Ø24 mm. 5. Regulation height: Between 75 and 95 mm. Metal trunks - CM The EMS technical floor box system has an additional complete system of metal trunks and accessories for below the surface, with all the required measurements and heights. 71

26 EMS has the following measurements: height 28 and 38 mm and width 150, 200, 250 and 300 mm. The trunks have interior compartments to separate the different types of cables, whilst at the same time increasing the trunk reinforcement. EMS supplies trunks with 2 and 3 compartments. For quick installation, EMS has developed a part that can be used for coupling, fixing and as a final cover for the trunks. Depending on its position, a revolving part that is placed on the ends serves as a final cover or for coupling-fixing. B. COMPLINCE WITH EXISTING STNDRDS COMPLINCE WITH THE UNE 20451:1997. Boxes and enclosures for electrical accessories for household and similar fixed electrical installations. Compliance with Standard IEC :2002. Boxes and enclosures for electrical accessories for household and similar fixed electrical installations - Part 1: General requirements. Compliance with Standard IEC Ed. 1: Boxes and enclosures for electrical accessories for household and similar fixed electrical installations - Part 23 : Particular requirements for floor boxes and enclosures Declaration of conformity MRKING. COMPLINCE WITH THE EUROPEN DIRECTIVE BT 73/23/EEC. Compliance with the standards UNE 20451:1997 and IEC 60670, with classification: CCORDING TO IEC Technical floor boxes for false floors (ST models) 7.1. Insulating Non-combustible floors Combustible floors Suitable for all types of installation except into concrete With inlets for plain or corrugated conduits (si se utiliza la caja BCM) With cable retention ºC to +60ºC 7.6. No aplicable Class Ha IP>2X 72

27 TECHNICL DT The classification of technical floor boxes according to point 7 of the standard CEI and which is in addition to the classification provided in section 7 of the general part, is for all technical floor boxes Floor boxes or enclosures intended to be installed in floor subjected to drytreatment Flush-floor enclosures intended to protect accesories against traffic load Enclosure with a removable lid. Insulating technical floor boxes for surface (CP models) 7.1. Insulating Non-combustible floors Suitable for installation into concrete during the casting process With inlets for plain or corrugated conduits With cable retention ºC to +60ºC ºC ENGLISH The classification of technical floor boxes according to point 7 of the standard CEI CD and which is in addition to the classification provided in section 7 of the general part, is for all technical floor boxes: Floor boxes or enclosures intended to be installed in floor subjected to drytreatment Flush-floor enclosures intended to protect accesories against traffic load Enclosure with a removable lid. Metal technical floor boxes for surface (CPM models) Composite Non-combustible floors Suitable for installation into concrete during the casting process With inlets for plain or corrugated conduits With inlets for other types of conductors/cables or conduits With cable retention ºC to +60ºC ºC The classification of technical floor boxes according to point 7 of the standard CEI CD and which is in addition to the classification provided in section 7 of the general part, is for all technical floor boxes: Floor boxes or enclosures intended to be installed in floor subjected to drytreatment Flush-floor enclosures intended to protect accesories against traffic load Enclosure with a removable lid. 73

28 C. DDITIONL TECHNICL TESTS PROTECTION FROM ELECTRIC SHOCKS Result of the test: IP4X ccording to IEC :2002. (10) EXTERNL LOD TEST Result of the test: Satisfactory ccording to UNE EN :2005 GLOW WIRE TEST Result of the test: Satisfactory. Degree of severity: 650ºC ccording to UNE EN HET RESISTNCE Result of the test: Satisfactory at 70ºC ccording to 20451:1997 COMPRESSION TEST FOR FLOOR MOUNTING BOXES Result of the test: Satisfactory ccording to IEC CDV D. SIZES 74

29 TECHNICL DT ENGLISH 75

30 76

31 TECHNICL DT ENGLISH 77

32 TECHNICL DT ENGLISH 79

33 80

34 TECHNICL DT / CPM 48-8 ENGLISH 7.- OFFICE SYSTEM. GENERL CHRCTERISTICS MTERILS MatInsulating material: Metal material: Self-extinguishing BS Silver anodised aluminium with satin finish COLOUR RL 7024 Graphite grey RL 9006 luminium RL 9003 White COMPLINCE WITH EXISTING STNDRDS UNE EN : Cable trunking systems and cable ducting systems for electrical installations. Part 1: General requirements. Pr EN : Cable trunking systems and cable ducting systems for electrical installations. Part 2-4: Specific requirements for Service Poles. UNE EN : Switches for fixed household and similar electrical installations. Part 1: General requirements. 81

35 B. SSEMBLY DIGRMS 8. MECHNISMS ELECTRIC SOCKETS RJ45 CONNECTORS ND HOLDERS PHONE SOCKETS SWITCHES OTHERS DIFFERENTIL TELEVISION SOCKET V 10/16 SOCKETS They comply with the UNE standard: Socket bases and plugs for household and similar use Product certified with the ENOR N mark, with dossier no. 030/ This certificate also guarantees compliance with all the requirements of the aforementioned standard. Main technical data: Material: Self-quenching technical polymer with high impact strength and against cleaning products and ultraviolet radiation. Terminals for cables of up to 4 mm2, rigid or flexible. Connection by means of mixed-head screws supplied loose for faster installation. Insulation resistance > 5 M_ at 500 V. Dielectric strength > 2000 V Minimum cutting power: 100 operations at 1.25*IN and 275 V, with cos_=0.6 Minimum service life: changes of position at IN and 250 V, with cos_= 0.8 Degree of protection according to UNE EN : IP-X DOUBLE 250 V SOCKETS SPECIFIC COVERS ND FUNCTIONS Double 250v sockets Field of application Power supply for computers, printers, cash registers, portable lighting appliances, and generally, all common equipment in the tertiary sector. 82

36 TECHNICL DT There are articles (refs: U3.069.XXSD) designed for connecting plugs with adaptors for selective seal opening. They are usually sent to installations with specific power supply systems (circuits with UPS, etc). ll sockets may be selected in red to indicate special circuits (UPS equipment, etc). Technical and installation characteristics llocated voltage: 250V ssembly by pressure on the frames without the need for screws. Terminals are aligned on both sides and internally connected. Terminals for conductors of up to 4 mm2, rigid or flexible. Connection of the phase and neutral terminals using mixed head screws and arched swing-arm washer ( yoke screw ), which enables a perfect cable grip, even where there is a difference in diameter. This technique is developed by Schneider Electric. Front tightening system makes it easier to tighten and loosen for maintenance operations. The cover is secured using a single screw. The socket is dismantled from the front of the frame using a simple unlocking system. There are articles with neon lights to indicate voltage in the socket. ll articles have safety seals. The covers are supplied in a shiny finish, signal white (RL 9003), pure white (RL 9010), aluminium and red. Technopolymer material that is resistant to abnormal heat and fire, halogen free and highly resistant to impact. The front parts are resistant to cleaning products and UV radiation. Standards ENGLISH In compliance with Standard UNE Insulation resistance: > 5MΩ a 500V Dielectric strength: > 2000V Minimum cutting power: 100 operations at 1.25 x IN and 275V, with cos = 0.6 Elastic and enclosing cells. During operations, the earth contact is established first, and it is stopped last. Minimum service life: changes of position at IN and 250V, with cos = 0.8 Sizes 83

37 8.3. CONTROL MECHNISMS (BREKERS ND SWITCHES) They comply with the UNE EN standard: : 2003: Switches for fixed, household and similar installations. Part 1: General prescriptions. Product certified with the ENOR N mark, with dossier no 030/ This certificate also guarantees assurance of all the requirements of the aforementioned standard. Main technical data: Shiny material resistant to cleaning products and stabilised versus UV radiation. RL 9003 White. Degree of protection according to UNE EN : IP-X1 Self-quenching material with high impact strength For the connection of rigid or flexible conductors to terminal strips. Insulation resistance > 5 M_ at 500 V. Dielectric strength > 2000 V Minimum cutting power: > 200 operations at 1.25*IN and 275 V, with cos_= 0.3 > 200 operations at 1.25* IN and 250 V, with tungsten filament lamps. Minimum service life: > changes of position at 1.25*IN and 250 V, with cos _= 0.6 > changes of position with fluorescent charge (mechanisms of 10 X) > 5000 changes of position with fluorescent charge (mechanisms of 16 X) 8.4. RJ 11 ND RJ 12 TELEPHONE SOCKETS (4 ND 6 WIRES, RESPECTIVELY) Compliance with the requirements of RD/1/1998 and RD 279/1999 (Telecommunications Common Infrastructure Regulation) (only 6 contacts sockets). For connection to the telephone network, modems, faxes and other telephony equipment. Category 3 (transmission speeds of up to 16 Mb/s) The typical line of 1 pair of wires is connected between L1 and L2, the connection of ISDN, DSL and other 4 wire lines (two pairs) is between L1-L2 and TX-TS. 84

38 TECHNICL DT Wiring diagram: RJ12 RJ12 TERMINL No SYMBOL ND COLOUR TX 3 L2 4 L1 5 TS 6 T RJ12 RJ12 ENGLISH Shiny material resistant to cleaning products and stabilised versus UV radiation. RL 9003 White. Self-quenching material with high impact strength RJ-45 CONNECTORS (8 WIRES) Category 5E (5 improved) Wiring system: Universal Insulating material: Self-quenching polycarbonate V0 according to UL 94 Contact material: Bronze / phosphorous (contact material); Nickel with gold film (contact mating area); Nickel with lead film (contact termination area plating). 85

39 ssembly diagram: 1 2 Trim Flush 3 4 CONTCT No EL/TI 568 Green-White Green Orange-White Blue Blue-White Orange Brown-White Brown Pair 3 Pair 1 Pair 4 Par 2 EL/TI568B Green-White Pair 2 Green Orange-White Blue Pair 1 Blue-White Orange Brown-White Brown Pair 4 Pair 3 86

40 TECHNICL DT 5.5. MGNETOTHERML ND DIFFERENTIL SWITCHES Field of application The automatic magnetothermal switches and automatic magnetothermal differential switches are used as a supplementary protection measure at the head of the installation. They thus make it possible to substantially increase the protection of the sensitive parts of the installation from overcurrents, short-circuits and branch faults. The automatic magnetothermal switches and automatic magnetothermal differential switches are used as a supplementary protection measure at the head of the installation. They thus make it possible to substantially increase the protection of the sensitive parts of the installation from overcurrents, short-circuits and branch faults. Power sockets for electronic devices (PC and accessories, typewriters, electronic scales, cash registers, etc.) This also allows us to reduce and locate the fault areas, thus obtaining better availability of the rest of the installation upstream from this additional protection system. ENGLISH Installation characteristics and techniques Rated voltage 230V Rated operational current (gage) and cut-off power of the automatic magnetothermal switches. Reference No. of poles gage () Cut-off power () N N N Rated operational current (gage) and cut-off power of the automatic magnetothermal differential switches. Reference No. of poles gage () Cut-off power () N N N The switch installed on a vertical wall with an IP41 degree of protection. The device should be used in a dry and powder-free place, with an ambient temperature between 5º to 40ºC. The circuit is closed by pressing the switch towards the «I» symbol. The circuit is opened by manually pressing the switch towards the «O» symbol, or automatically by a thermal or magnetic action. In the magnetothermal differential switches the circuit is also opened by pressing the test button «T» and automatically by differential action. 87

41 5.6. TELEVISION SOCKETS TELEVISION SOCKETS Installation characteristics: EMS Prepare the coaxial cable according to the measures specified in the following figure: Make sure that no wire of the outside mesh touches the central wire (live). Raise the main lid of the socket and fit the cable/s according to the following photo: On installing two cables (in the Intermediate series sockets) check that the cable matches the position indicated by the arrows on the signal input and signal output socket. Lower the lid and screw it down tightly. LIDS FOR STNDRD MRKET SOCKETS EMS The lids with ref. U9.440.XX and U9.441.XX make it possible to provide the standard TV bases with the UNIC finish (such as TELEVES, IKUSI, etc.). Zip-type guides must be removed from the fmae, as indicated in the attached drawings. Standards: EMS EN , EN , EN UNE (2nd) DIN DIN EMC Guideline 88

42 TECHNICL DT Dimensions: EMS SM TV socket Lid ENGLISH 6. DDITIONL TECHNICL INFORMTION CONNECTOR COMPTIBILITY MP REF. CONNECTOR TYPE WIDTH NRROW x x x x x UTP STP UTP STP UTP STP UTP Cat. 6 Cat. 5e Cat. 5 Cat. 3 VY REF. CONNECTOR TYPE WIDTH NRROW MGS400-xxx MPS100E-xxx UTP Cat. 6 Cat. 5e 89

43 BRND REX REF. CONNECTOR TYPE WIDTH NRROW C6C-JK-U-01-2 C6C-JK-U-01-3 C6C-JK-F-0K-2 C6C-JK-F-K-2 C6C-JK-F-BK-2 GPC-JK-U-B1-3 GPC-JK-U-1-3 GPC-JK-U-BK-3 GPC-JK-U-K-3 GPC-JK-U-013LF GPC-JK-F-01-2LF GPC-JK-F-B1-2 GPC-JK-1-3 GPC-JK-BK-2 GPC-JK-K-3 UTP FTP UTP FTP Cat. 6 Cat. 5e GENERL CBLE REF. CONNECTOR TYPE WIDTH NRROW CU6PJCBLP CU6PJKBLP CU5EJCBLP CU5EJKBLP CF5NJC99P CU5PJCBLP CF5PJC99P UTP FTP UTP FTP Cat. 6 Cat. 5e Cat. 5 KRONE REF. CONNECTOR TYPE WIDTH NRROW xx xx xx UTP STP UTP STP UTP STP UTP STP UTP Cat. 6 Cat. 5e * (*) fter wiring, remove the sliding clamp from the connector. 90

44 TECHNICL DT NEXNS REF. CONNECTOR N N N N N N N N UTP FTP STP UTP FTP STP UTP FTP TYPE Cat. 6 Cat. 5e WIDTH Note: The article Ref.: by NEXNS, must be used with these connectors NRROW ENGLISH NORDX/CDT REF. CONNECTOR TYPE WIDTH NRROW X a X a X a UTP Cat. 6 Cat. 5e SUPERIOR REF. CONNECTOR TYPE WIDTH NRROW KMJSIXB02 KMJVL8/B02S KMJVL8/B02 KMJE3FS8B02 UTP FTP UTP Cat. 6 Cat. 5e 91

45 Much more than products. EMS was created in 1978 as a company dedicated to the wholesale design, development and manufacture of Low Voltage cables, products and accessories for the electricity industry. Our mission involves offering a wide range of solutions that meet with our customers most demanding requirements or go far beyond them, offering at all times a product and service with the quality they would expect of a company with the profile of EMS. From the outset EMS has maintained a solid philosophy aimed at offering a specific product and integral service that is totally adapted to meet each customers needs. EMS currently has more than 20,000 m2 of installations in three operations centres, equipped with the very latest technology used for production, storage and design processes. Norma System, Mini System, Connect System and Installation Material are the four main lines of EMS products. Four areas especially defined to cover each and every one of the needs of the electrical sector. 92

46 LBORTORY ND QULIT CONTROL ENGLISH Quality from the outset From its very beginnings, quality has always been at the forefront of EMS s management system EMS sets its General Quality Plan underway, with the aim of continuously improving its products, processes and services in order to obtain the highest levels of customer satisfaction Thanks to the constant efforts of a team of great professionals, EMS is awarded the ISO 9001 quality certificate, one of the first companies in the sector to receive it EMS s efforts in the area of quality control are awarded with the ISO 4001 Environmental Management certificate EMS becomes the first company in the electricity sector to receive the SGI- 008/2003 certificate (Integral Management Certificate combining Quality Control and Environmental systems) from the Spanish certifying authority, ENOR. t present, very few companies have been awarded this certification. However, our respect towards the environment and the quality of our processes is not just aimed at obtaining certificates, but instead the correct and intelligent use of our natural resources and respect towards our environment, our team and our customers. 93

47 TESTS PERFORMED BY SYSTEMS CERTIFICTION PRODUCT CERTIFICTION 1.- CONTROL MECHNISMS Narrow Breaker 16ª Wide Breaker Narrow Switch Wide switch Wide pushbutton 10 ENOR Product Certificate no. 030/ POWER SOCKETS Schuko Base 2P+EC Schuko base 2P+EC safety Red Schuko base 2P+EC safety Red French base 2P+EC safety White French base 2P+EC safety Narrow Plug base 2P narrow Wide plug base 2P safety ENOR Product Certificate no. 030/

48 3.- MECHNISM HOLDERS FOR INSULTING CM/CD TRUNKS CM-CP Mechanism Holder CD 110 Mechanism Holder CD 160/CS Mechanism Holder 4.- MULTIFUNCTION BOXES CS CS SUP + MGT Holder CS CS SUP + MGT Holder CS CS SUP + MGT Holder CS CE CE BUILT-IN PLDUR + MGT Holder CE CE BUILT-IN PLDUR + MGT Holder CE CE BUILT-IN PLDUR + MGT Holder CE CEO CEO BUILT-IN + MGT Holder CEO CEO BUILT-IN + MGT Holder CEO CEO BUILT-IN + MGT Holder CEO - 8 ENGLISH QULIFICTIONS ND OFFICIL PPROVLS CE TELEFÓNIC VODFONE EL CORTE INGLÉS REPRO GENCI DE PROTECCIÓN CONTR INCENDIOS REPÚBLIC DE CUB 95

49 / ST-8

50 CONSULT OUR 3 TECHNICL MNULS 48

3F Linda Inox 1x.. T8 HF ATEX II 3D T85 C IP65

3F Linda Inox 1x.. T8 HF ATEX II 3D T85 C IP65 3F Linda Inox 1x.. T8 HF ATEX II 3D T85 C IP65 Product Technical Sheet 18, 36 and 58W single-lamp versions ST.0914.I Summary Application field 3 Structural characteristics 4 Electrical characteristics

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Schedule of ccreditation United Kingdom ccreditation Service ccredited to Holmesfield Road Warrington Cheshire W1 2DS Contact: Mr D Brown Tel: +44 (0)1925-655116 Fax: +44 (0)1925-655419 E-Mail: david.brown@exova.com

More information

Kickspot Self-testing/AutoDiag self-contained emergency lighting unit

Kickspot Self-testing/AutoDiag self-contained emergency lighting unit CONTENTS Page 1. Description.............................1 2. Installation.............................2 3. Connection.............................4 4. Use......................................8 5. Maintenance...........................9

More information

135'c " Conduit, 6-#3, 12-#4 Wires Rated-50% 45'c 345'w. 1" Conduit, 3-#4 3.43%VD. 66'c 411'w 4.08%VD. Wires Rated-50% 77'c. 421'w 14 4.

135'c  Conduit, 6-#3, 12-#4 Wires Rated-50% 45'c 345'w. 1 Conduit, 3-#4 3.43%VD. 66'c 411'w 4.08%VD. Wires Rated-50% 77'c. 421'w 14 4. ,, Panelboard NEM R enclosure. 90 positions 18K breakers Extend existing concrete base per base details. Paint panel very dark green which is close to the panel across the street. Use existing meter. 58'

More information

Smoke control dampers

Smoke control dampers X X testregistrierung Smoke control dmpers Type with BLE- ctutor CE complint ccording to Europen regultions For mechnicl smoke extrct systems nd s n dditionl supply ir inlet Rectngulr smoke control dmpers

More information

new new Industrial plugs and sockets

new new Industrial plugs and sockets Industrial plugs and sockets 213.1633 213.3236 221.1633 226.1636 New Optima series 16A-32A-63A-125A insulation voltage : 690V AC protection degree : IP44 and IP67 operating temperature : -25ºC to 40ºC

More information

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable. Product Specification 108-93018 25/Aug/2011 Rev H Copper LAN cable 1. SCOPE 1.1. Content This specification describes the general requirements for AMP NETCONNECT* copper LAN cable. 2. APPLICABLE DOCUMENTS

More information

ORDERING INFORMATION NO = DIM = NOTES. Contact factory for 347V WIRELESS DMX COMPONENTS REQUIRED FOR WRCN EXTERIOR - LEADER CABLES

ORDERING INFORMATION NO = DIM = NOTES. Contact factory for 347V WIRELESS DMX COMPONENTS REQUIRED FOR WRCN EXTERIOR - LEADER CABLES SHPING THE EXPERIENCE OF LIGHT PTENT PENDING FCDE & FLOOD LIGHTING WHITE LIGHT, STTIC RED, BLUE, GREEN, MBER Line voltage LED, High Performance Facade and Flood Lighting Ideal for lighting facades, structures,

More information

UV Flame Supervision System

UV Flame Supervision System 7 783 UV Flame Supervision System DETACTOGYR LFE50 Series 02 ISO 9001 The LFE50 is a self-checking UV flame supervision system designed for use with continuously operating burners or for burners running

More information

QRA10... QRA53... QRA55...

QRA10... QRA53... QRA55... 7 712 QRA7 with clamp QRA10... QRA53..., QRA55... with clamp QRA2... with clamp Flame Detectors QRA2... QRA10... QRA53... QRA55... QRA73 QRA75 The UV flame detectors are designed for use with Siemens burner

More information

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE Cat. N STOP & GO automatic resetting 87045 LIMOGES Cedex - FRANCE Telephone : + 33 5 55 06 87 87 Fax: + 33 5 55 06 88 88 Cat. N (s) : 4 062 88 / 4 062 89 CONTENTS PAGE 1. Description - Use... 1 2. Product

More information

Flexibility from floor to ceiling

Flexibility from floor to ceiling Product Overview Catalogue Flexibility from floor to ceiling Overview Established in 1920, Clipsal by Schneider Electric is Australia s number one brand of electrical products, accessories and solutions

More information

NURSE CALL SYSTEM SPECIFICATION

NURSE CALL SYSTEM SPECIFICATION NURSE CALL SYSTEM SPECIFICATION MICRO NURSE CALL SYSTEMS cc 011 499 1145 Members: Jose Da Silva, Wennie Opperman, Vernon Breet INDEX Page 3 - General Description System Components Page 4 - Description

More information

CATEGORY 6A FTP RJ45 SOLUTION

CATEGORY 6A FTP RJ45 SOLUTION CATEGORY 6A FTP RJ45 SOLUTION Clipsal titanium Patch Cord Clipsal titanium LSZH Patch Cord Clipsal titanium Keystone Jacks Clipsal titanium Modular Jacks Clipsal titanium Patch Panels Clipsal titanium

More information

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-11035-03-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 25.10.2017 to 24.10.2022 Holder of certificate: DMT

More information

NEXT DL NEXT DL. rcgroupairconditioning

NEXT DL NEXT DL. rcgroupairconditioning NEXT DL: Close control air conditioners with displacement air delivery with remote condenser, or built in water cooled condenser or for chilled water feeding Cooling capacity: 7,7 51,4 NEXT DL rcgroupairconditioning

More information

Mosaic TM LCS2 Cat. 6A STP RJ 45 socket

Mosaic TM LCS2 Cat. 6A STP RJ 45 socket 870 LIMOGES Cedex Telephone: + 33 0 5 55 06 87 87 - Fax: + 33 0 5 55 06 88 88 Mosaic TM LCS2 socket Page 765 73 794 76 1. General characteristics....1 2. Presentation...1 3. Installation...1 4. Technical

More information

WS Circular symbol with red border and bar, black pictogram on white background. Used to prohibit specific acts that could be dangerous.

WS Circular symbol with red border and bar, black pictogram on white background. Used to prohibit specific acts that could be dangerous. SIGNS SIGNstick-onsys: a wide range of self adhesive signs, in various types and formats, for comprehensive signing of all potentially hazardous situations in factories, workshops and industrial premises.

More information

DAVE Supply (DS) Fans For Internal & External Use Installation and Maintenance

DAVE Supply (DS) Fans For Internal & External Use Installation and Maintenance 1.0 INTRODUCTION DVE Supply Fans For Internal & External Use Installation and Maintenance The Dave range of in-line backward curve fans consists of 9 sizes with a maximum duty of 1.1m3/s (1100l/s). Units

More information

Compliance with EN : 2006 Electrical apparatus for explosive atmospheres Type of Protection «n» for Zone 2

Compliance with EN : 2006 Electrical apparatus for explosive atmospheres Type of Protection «n» for Zone 2 Compliance with EN60079-15: 2006 Electrical apparatus for explosive atmospheres Type of Protection «n» for Zone 2 RJ11FTVX series: rugged and sealed RJ11/12 connectors Report Prepared by : Amphenol Socapex

More information

QRA2... QRA10... QRA53... QRA55... Flame Detectors. Siemens Building Technologies HVAC Products

QRA2... QRA10... QRA53... QRA55... Flame Detectors. Siemens Building Technologies HVAC Products 7 712 ISO 9001 QRA10... QRA53..., QRA55... with clamp QRA2... with clamp Flame Detectors QRA2... QRA10... QRA53... QRA55... The flame detectors are designed for use with our burner controls, for the supervision

More information

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE 2 GLEC-6 - Installation and maintenance CONTENTS 1 Important information... 3 2 Safety notes... 3 3 Technical description...4 4 Transport... 6 5

More information

EAE/EAES «HEPHEA 248» Product Technical Instructions

EAE/EAES «HEPHEA 248» Product Technical Instructions Page : 1/7 TABLE OF CONTENTS A. GENERAL FEATURES... 2 1. GENERAL INFORMATION... 2 2. DESIGN... 2 3. FUNCTIONAL FEATURES... 2 4. TECHNICAL FEATURES... 3 B. INSTALLATION AND CONNECTING... 4 1. SUPPLY UNIT

More information

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag STANDARD COLOR CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag TECHNICAL DATA SHEET Revision Number. 1 Last Edited 9. januar 2019 OTHER COLORS MATERIAL Flat band cross linked polyolefin. OPERATING

More information

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02 7 783 ISO 9001 DETACTOGYR Flame Safeguard Series 02 The... together with the QRA50M / QRA51M form a self-checking flame supervision system (DETACTOGYR ) designed for use with continuously operating oil

More information

TubeLine LED unit Optimised comfort with a linear LED solution

TubeLine LED unit Optimised comfort with a linear LED solution Lighting LED unit Optimised comfort with a linear LED solution Fluorescent linear lighting has traditionally been the preferred choice for customers demanding a high level of visual comfort. With excellent

More information

Eldon Product Overview

Eldon Product Overview Eldon Product Overview Product overview Floor Standing Enclosures page 4 Thermal Management page 32 Human Machine Interface page 26 Wall Mounted Enclosures page 12 Accessories page 38 Terminal Boxes page

More information

U tube models PTU 09, 12, 15, 25, 30, 35, 40, 45. single linear tube models PTS 09, 12, 15, 25, 30, 35, 40, 45

U tube models PTU 09, 12, 15, 25, 30, 35, 40, 45. single linear tube models PTS 09, 12, 15, 25, 30, 35, 40, 45 U tube models PTU 09, 2, 5, 25, 30, 35, 40, 45 & single linear tube models PTS 09, 2, 5, 25, 30, 35, 40, 45 installation, servicing & operating instructions INSTALLATION, SERVICING AND OPERATING INSTRUCTIONS

More information

Outdoor Enclosures. Outdoor Enclosures Protected like a bunker for all harsh environments

Outdoor Enclosures. Outdoor Enclosures Protected like a bunker for all harsh environments Outdoor Enclosures Outdoor Enclosures Protected like a bunker for all harsh environments sales@mcldatasolutions.co.uk +44(0)1702 443810 mcldatasolutions.co.uk Outdoor enclosures and climate control components

More information

PANEL. Cableflow International Limited

PANEL. Cableflow International Limited Cableflow International Limited PANEL TM The PANEL, a simple yet understated name for this extremely flexible medical supply unit, embodies our experience and innovative approach to bedhead services attained

More information

QRA10... QRA53... QRA55...

QRA10... QRA53... QRA55... 7 712 QRA7 with clamp QRA10... QRA53..., QRA55... with clamp QRA2... with clamp Flame Detectors QRA2... QRA10... QRA53... QRA55... QRA73 QRA75 The UV flame detectors are designed for use with Siemens burner

More information

Arteor TM LCS2 Cat. 6A UTP RJ 45 socket

Arteor TM LCS2 Cat. 6A UTP RJ 45 socket 87045 LIMOGES Cedex Telephone: + 33 0 5 55 06 87 87 - Fax: + 33 0 5 55 06 88 88 Arteor TM Page 5 723 49 5 723 57 1. General characteristics....1 2. Presentation...1 3. Real life scenarios...1 4. Technical

More information

Electronic control unit for gas leak detection with 4 detection zones

Electronic control unit for gas leak detection with 4 detection zones P82 Electronic control unit for gas leak detection with 4 detection zones Electronic control unit for gas leak detection in industrial environment, suitable for controlling and signaling dangerous gas

More information

Plugs & sockets. Industrial plugs and sockets Scame I-1 5. Industrial switched sockets. Scame I-4 6. Distribution boards.

Plugs & sockets. Industrial plugs and sockets Scame I-1 5. Industrial switched sockets. Scame I-4 6. Distribution boards. 7% Plugs & sockets I Industrial plugs and sockets Scame I-1 5 Industrial switched sockets Scame I-4 6 Distribution boards Scame I-7 8 Industrial plug adaptors Scame I-8 Weatherproof switches and sockets

More information

TUNNELS BOXES AND CONNECTORS

TUNNELS BOXES AND CONNECTORS TUNNELS BOXES AND CONNECTORS MARECHAL ELECTRIC is now a leading company in the electric connection for tunnels. Based on technology specially intended for such difficult environments and quick light disconnection,

More information

Silicon UVAB Sensor E xxx

Silicon UVAB Sensor E xxx THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021201/11/03 Silicon UVAB Sensor E 1.1 7.1416.10.xxx ADOLF THIES GmbH & Co. KG Hauptstraße 76 37083

More information

70XXA-1 series. Voltage. Features. Applications. Description. Order Information. Designator Symbol Description 1 2 Integer Output Voltage(2.2~7.

70XXA-1 series. Voltage. Features. Applications. Description. Order Information. Designator Symbol Description 1 2 Integer Output Voltage(2.2~7. Fetures Low power consumption Low temperture coefficient Builtin hysteresis chrcteristic High input voltge (up to 24) Output voltge ccurcy: tolernce ±2% TO92, SOT89 nd SOT23 pckge Applictions Bttery checkers

More information

fire resistant cables

fire resistant cables Building Technology fire resistant cables Special electrical and optical cables www.tecnikabel.com Special electrical and optical cables 2 INTRODUCTION Structured cabling solutions. Tecnikabel can provide

More information

Annex of the certificate (Page 1/5) Accreditation Scope

Annex of the certificate (Page 1/5) Accreditation Scope Annex of the certificate (Page 1/5) Accreditation Scope As a Testing Laboratory Tested Materials / Products EX LABORATORY Metallic materials Construction products Address: Küçük Çiğli Mh. 8780/1 Sk. No:5

More information

unico pf unico pf rcgroupairconditioning

unico pf unico pf rcgroupairconditioning : ckaged air cooled liquid chillers for indoor installation, equipped with scroll compressors and plug fan Cooling Capacity: 19,6 264 unico pf PLTE rcgroupairconditioning R410 E C MIN FETURES ir cooled

More information

INSTALLATION MANUAL. Decoration Panel Provided with Filter Auto Cleaning Function Self Cleaning decoration panel BYCQ140D7GW1 BYCQ140D7GFW1

INSTALLATION MANUAL. Decoration Panel Provided with Filter Auto Cleaning Function Self Cleaning decoration panel BYCQ140D7GW1 BYCQ140D7GFW1 INSTALLATION MANUAL Decoration Provided with Filter Auto Cleaning Function Self Cleaning decoration panel BYCQ0D7GW BYCQ0D7GFW BYCQ0D7GW BYCQ0D7GFW Installation manual Contents. SAFETY PRECAUTIONS....

More information

Welcome to Hager Presentation

Welcome to Hager Presentation Welcome to Hager Presentation Topics Intro to Hager Group Circuit Protection Enclosures Q&A IIEE Manila 4 th August 17 13.03.2009 2 Company presentation Who we are Hager Group is a leading provider of

More information

TUNNELS BOXES AND CONNECTORS

TUNNELS BOXES AND CONNECTORS TUNNELS BOXES AND CONNECTORS MARECHAL ELECTRIC is now a leading company in the electric connection for tunnels. Based on technology specially intended for such difficult environments and quick light disconnection,

More information

FIRE PROTECTION INNOVATORS IN CABLE MANAGEMENT

FIRE PROTECTION INNOVATORS IN CABLE MANAGEMENT FIRE PROTECTION INNOVATORS IN CABLE MANAGEMENT Power Data Control Ventilation of cables Installed cost reduction Proven suitability Mechanical protection Free draining EMC protection Adaptability Bypasses

More information

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT INTERNATIONAL TELECOMMUNICATION UNION ITU-T L.36 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (10/98) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

More information

Lloyd s Register Type Approval System Test Specification Number 3

Lloyd s Register Type Approval System Test Specification Number 3 Working together for a safer world Lloyd s Register Type Approval System Test Specification Number 3 July 2015 Performance Test Specification for Equipment to be used in Marine Applications: Electric Cables

More information

VEROTEC Electronics Packaging

VEROTEC Electronics Packaging EROTEC Electronics Packaging Thermal Thermal alue Added Services from erotec Custom Thermal (s) TecServ is the vehicle by which erotec delivers its value added services. These fall within 5 main categories

More information

An Urgent Bulletin from CSA Group

An Urgent Bulletin from CSA Group n Urgent ulletin from CS Group Heating and Cooling Equipment No. 9 (Supersedes Notice Heating & Cooling Equipment No. 7, Ref No: N13-075) Date: December 16, 2015 See ttachment 1 for Effective Dates. See

More information

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 4.1 Electrical limit switch... 4

More information

TECHNICAL MANUAL EXPLOSION PROOF STATUS LIGHT / LAMP BSL 125 / BSL 150. Scope: EXcite USER MANUAL BSL 125 / BSL 150. Date:

TECHNICAL MANUAL EXPLOSION PROOF STATUS LIGHT / LAMP BSL 125 / BSL 150. Scope: EXcite USER MANUAL BSL 125 / BSL 150. Date: Page 1 of 9 TECHNICL MNUL EXPLOSION PROOF STTUS LIGHT / LMP TEX Marking: Code: II 2GD EPL Gb, Db Ex d IIC T4/T5/T6 IP66 Ex tb IIIC TXXX C Marking details: Please note that every care has been taken to

More information

ELSTA MOSDORFER- Energy Distribution with Competence

ELSTA MOSDORFER- Energy Distribution with Competence PRODUCT RANGE ELSTA MOSDORFER- Energy Distribution with Competence Quality and Standards We are your reliable partner for electrical energy distribution, industrial control and automation engineering.

More information

ELECTRIC FAN HEATERS Devil 6002, 6003, 6005, 6009 & 6015

ELECTRIC FAN HEATERS Devil 6002, 6003, 6005, 6009 & 6015 ELECTRIC FN HETERS Devil 600, 6003, 6005, 6009 & 605 Part Nos: 6958, 6950, 6955, 69530 & 69535 OPERTING & MINTENNCE INSTRUCTIONS GC0 INTRODUCTION Thank you for purchasing this CLRKE Electric Fan Heater.

More information

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required) FLUORESCENT LIGHTING RMS-560.. Series - Fluorescent lighting fixtures TECHNICAL FEATURES RMS.. series lighting fixtures are ideally suited for ON and OFF-SHORE applications and all kinds of industries

More information

QRA10... QRA53... QRA55...

QRA10... QRA53... QRA55... 7 712 QRA10... QRA53..., QRA55... with clamp QRA2... with clamp Flame Detectors QRA2... QRA10... QRA53... QRA55... The UV flame detectors are designed for use with Siemens burner controls, for the supervision

More information

MY HOME LaYOut Of the building 22

MY HOME LaYOut Of the building 22 22 MY HOME Layout of the building LAYOUT OF THE BUILDING SECTION CONTENTS General rules for installation 24 Type of wiring 28 Devices in flush-mounting boxes 30 Devices in surface-mounting boxes 32 Rules

More information

FM MEDICOL. Cableflow International Limited. The FLUSH MEDICOL (FM) Patient Care Services. Column has evolved from a market requirement for a

FM MEDICOL. Cableflow International Limited. The FLUSH MEDICOL (FM) Patient Care Services. Column has evolved from a market requirement for a Cableflow International Limited TM FM MEDICOL The FLUSH MEDICOL (FM) Patient Care Services Column has evolved from a market requirement for a stylish adaptable vertical trunking system which can be wall

More information

Approved by: Document no.: EGT

Approved by: Document no.: EGT ET Page 1 of 6 TECHNICL MNUL EXPLOSION PROOF MNUL CLL POINT / PUSH BUTTON TEX Marking: Code: II 2D EPL b, Db Ex d IIC T6 IP66 Ex tb IIIC T85 C Marking details: Please note that every care has been taken

More information

+ = ECO-STAR System. Ecology Series (Distribution boxes) + Star Series (Boxes for industrial sockets) ECOLOGY Technical Specifications

+ = ECO-STAR System. Ecology Series (Distribution boxes) + Star Series (Boxes for industrial sockets) ECOLOGY Technical Specifications + = ECO-STAR System Ecology Series (Distribution boxes) + Star Series (Boxes for industrial sockets) STAR Technical Specifications - Degree of protection: IP65. - Resistance to impact: IK08. - Glow wire

More information

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D PL 17819 01 00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 29.06.2017 to 10.08.2019 Holder of certificate: MPA

More information

Havells Fire Survival Cables

Havells Fire Survival Cables Fire Survival Cables Designed for Critical Installation of National Importance Airports / Thermal Power Plants Metro Rail Projects / Rail Terminals / Nuclear Interstate Bus Terminals / Installation Prone

More information

Student Services & Classroom Addition. A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

Student Services & Classroom Addition. A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards. SECTION 262416 - PANELBOARDS PART 1 - GENERAL 1.1 SUMMARY A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards. 1.2 PERFORMANCE REQUIREMENTS A. Seismic Performance:

More information

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218 CONTENT 1. Manufacturer 1 2. General safety informations 1 3. Purpose 2 4. Product compliance 2 5. Degree of protection and technical data 2 6. Type 3 7. Mounting and installation 3 8. Dimensions 6 9.

More information

IR FLAME DETECTOR RIV-601/F

IR FLAME DETECTOR RIV-601/F IR FLAME DETECTOR EN 54-10 class 2 VdS approval G 205044 application manual CONTROL LOGIC rev. 4 DEC07 MAFE DEC07 IR FLAME DETECTORS SUMMARY Page general notions...3 description...4. Electrical and general

More information

Fire dampers. Type FKA-EU. For diverse applications

Fire dampers. Type FKA-EU. For diverse applications . X X testregistrierung Fire dmpers Type with fusible link for 72 C CE complint ccording to Europen regultions For diverse pplictions Rectngulr fire dmper for the isoltion of duct penetrtions between two

More information

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23 Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B Type B 23 on the wall Ø 80 duct, available in the following lengths: 1000,

More information

WALL MOUNT COMBINATION GAS HEATER SERIES. HIGH EFFICIENCY HYDRONIC HEATERS WITH BUILT-IN DOMESTIC HOT WATER

WALL MOUNT COMBINATION GAS HEATER SERIES. HIGH EFFICIENCY HYDRONIC HEATERS WITH BUILT-IN DOMESTIC HOT WATER WLL MOUNT COMBINTION GS HETER SERIES. HIGH EFFICIENCY HYDRONIC HETERS WITH BUILT-IN DOMESTIC HOT WTER XI COMBI Wall Mounted Direct Vent Sealed Combustion Quiet & Efficient On-demand Hot Water The xia series

More information

Arteor TM LCS2 Cat. 6A STP RJ 45 socket

Arteor TM LCS2 Cat. 6A STP RJ 45 socket 87045 LIMOGES Cedex Telephone: + 33 0 5 55 06 87 87 - Fax: + 33 0 5 55 06 88 88 Arteor TM Page 5 723 06 5 723 50 1. General characteristics....1 2. Presentation...1 3. Real life scenarios...1 4. Technical

More information

Fire dampers. Type FK-EU. For diverse applications

Fire dampers. Type FK-EU. For diverse applications . X X testregistrierung Type with fusible link for 72 C or 95 C CE complint ccording to Europen regultions With TROXNETCOM s n option ATEX certifiction For diverse pplictions Rectngulr fire dmper for the

More information

Fire dampers. Type FK-EU. For diverse applications

Fire dampers. Type FK-EU. For diverse applications . X X testregistrierung Fire dmpers Type with fusible link for 72 C or 95 C CE complint ccording to Europen regultions With TROXNETCOM s n option ATEX certifiction For diverse pplictions Rectngulr fire

More information

B. Shop Drawings: List of legends and description of materials and process used for premarking wall plates.

B. Shop Drawings: List of legends and description of materials and process used for premarking wall plates. SECTION 262726 - WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236 CONTENT 1. Manufacturer 1 2. General safety informations 1 3. Purpose 2 4. Product compliance 2 5. Degree of protection and technical data 2 6. Type 3 7. Mounting and installation 3 8. Dimensions 6 9.

More information

A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards. SECTION 262416 - PANELBOARDS PART 1 - GENERAL 1.1 SUMMARY A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards. 1.2 PERFORMANCE REQUIREMENTS A. Seismic Performance:

More information

Installation Instructions. Mira LED Light System

Installation Instructions. Mira LED Light System Installation Instructions Mira LED Light System w w w. a m i c o. c o m Contents Symbols Used in This Manual 4 Safety Instructions 5 Variants 7 Scope Of Delivery 8 Installing Mira LED Ceiling Mounted Installing

More information

CLIMACIAT AIRTOP. Air handling units. Very short delivery time Double wall with 50 mm insulation. Complete range meeting all the tertiary requirements

CLIMACIAT AIRTOP. Air handling units. Very short delivery time Double wall with 50 mm insulation. Complete range meeting all the tertiary requirements Excellent quality / price ratio Very short delivery time Double wall 50 mm insulation Complete range meeting all the tertiary requirements Air flow : 000 to 7 000 m 3 /h DESCRIPTION Casing Double wall

More information

SOLUZIONI PER ATMOSFERA ESPLOSIVA

SOLUZIONI PER ATMOSFERA ESPLOSIVA catalogo ATEX 2015 SOLUZIONI PER ATMOSFERA ESPLOSIVA ATEX catalogue book 2016 SOLUTIONS FOR EXPLOSIVE ATMOSPHERES Since 1904 In 1904 PALAZZOLI began its activity in Brescia when electrical energy was first

More information

Snifter ATEX22 VERSION. User Manual. Distributor

Snifter ATEX22 VERSION. User Manual. Distributor Snifter ATEX22 VERSION User Manual Distributor Version 1.4 09/09/2009 Table of Contents 1. INTRODUCTION... 3 1.1. Safety... 3 1.2. Product overview... 4 1.3. How does it work?... 4 2. INSTALLATION... 5

More information

Switches compliant with ATEX directive

Switches compliant with ATEX directive Switches compliant with ATEX directive General Catalogue - Technical concepts page Position switches FD / FL series page 9 / Category Zone EPL Approvals 2G Gb Mb II 2G Ex ia IIC T6 Gb I Ex ia I Mb Product

More information

ELECTRIC FAN HEATERS Devil 6002, 6003, 6005, 6009 & 6015

ELECTRIC FAN HEATERS Devil 6002, 6003, 6005, 6009 & 6015 ELECTRIC FN HETERS Devil 600, 6003, 6005, 6009 & 605 Part Nos: 6958, 6950, 6955, 69530 & 69535 OPERTING & MINTENNCE INSTRUCTIONS GC077 - ISS 7 INTRODUCTION Thank you for purchasing this CLRKE Electric

More information

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour. 67 POWERFLEX RV-K POWERFLEX RV-K Industrial flexible cable for power transmission. 1 IEC 60502-1 - UNE 21123-2 DESIGN 1. Conductor 2 Electrolytic copper, class 5 (flexible), based on EN 60228 and IEC 60228.

More information

PASSION FOR POWER. COMPANY PROFILE. More information at made in GERMANY. since 1931

PASSION FOR POWER. COMPANY PROFILE. More information at   made in GERMANY. since 1931 PASSION FOR POWER. COMPANY PROFILE More information at www.hensel-electric.de/en made in GERMANY since 1931 made in GERMANY since 1931 HENSEL - our passion is perfection Electrical power drives us forward.

More information

Dryflex FLAM. Halogen-Free Flame Retardant TPEs

Dryflex FLAM. Halogen-Free Flame Retardant TPEs Dryflex FLAM Halogen-Free Flame Retardant TPEs CONTENTS BRAND NAMES & NOMENCLATURE INTRODUCTION KEY PROPERTIES FLAM 600 SERIES FLAM 700 SERIES TYPICAL APPLICATIONS EXPLANATION OF FLAMMABILITY TESTS PROCESSING

More information

ABH BASIN HEATER CONTROLS PACKAGE. engineering data and specifications

ABH BASIN HEATER CONTROLS PACKAGE. engineering data and specifications BH BSIN HETER CONTROLS PCKGE engineering data and specifications BH Basin Heater Control Package 2 BH DVNCED BSIN HETER CONTROLS The Marley BH basin heater package controls the ON and OFF operation of

More information

(Notices) EUROPEAN COMMISSION

(Notices) EUROPEAN COMMISSION 14.8.2012 Official Journal of the European Union C 245/1 IV (Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION Commission communication in the framework

More information

Customer Operation & Installation Manual Electric Panel Heaters

Customer Operation & Installation Manual Electric Panel Heaters Customer Operation & Installation Manual Electric Panel Heaters MODELS: JEPH-10DTW / JEPH-15DTW / JEPH-22DTW For safe and reliable operation and optimum performance this appliance must be operated, installed

More information

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR 7 783 DETACTOGYR Flame Safeguard The... together with the QRA50M / QRA51M form a self-checking flame supervision system (DETACTOGYR ) designed for use with continuously operating oil or gas burners or

More information

Frost Protection Thermostat

Frost Protection Thermostat 1 203 Frost Protection Thermostat Electromechanical thermal reset limit thermostat RAK-TW.5..H RAK-TW.5..H.. Use Monitoring of frost protection temperature, with single-pole changeover microswitch Switching

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MNUL (TEX / IECEx) ExG21D Flameproof Xenon eacon For use in Flammable Gas and Dust tmospheres 1) Introduction The ExG21D is a flameproof beacon certified to meet the requirements of the TEX

More information

OPERATION SERVICE AND INSTALLATION MANUAL

OPERATION SERVICE AND INSTALLATION MANUAL OPERTION SERVICE ND INSTLLTION MNUL DUCTIR Congratulations you have made a wise choice with the purchase of your Lennox are conditioning set This product has been designed, assembled and supplied in one

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Product Test Centre 15 Progress Road Eastwood Leigh-on-Sea Essex SS9 5JA Contact: Mr S Bailey Tel: +44 (0)1702 425738 E-Mail: stuart.bailey@honeywell.com

More information

AS/NZS :2003 Luminaires - Part 1: General requirements and tests

AS/NZS :2003 Luminaires - Part 1: General requirements and tests Menu Home About this portal Latest updates Print Save Email Resource detail Citations AS/NZS 60598.1:2003 Luminaires - Part 1: General requirements and tests Table of Contents View on Information Provider

More information

GEYSER kw. General information. Unique selling points

GEYSER kw. General information. Unique selling points 6 78 kw General information Dedicated heat pumps new series with Scroll compressors, with and without vapor injection. /HT version in 15 sizes Cooling capacity (35;W7): 6 73 KW Heating capacity (7;W45):

More information

REGISTER OF NEW NATIONAL STANDARDIZATION INITIATIVES NOTIFIED UNDER SUBSECTORS IN THE SCOPE OF CENELEC. March 2014

REGISTER OF NEW NATIONAL STANDARDIZATION INITIATIVES NOTIFIED UNDER SUBSECTORS IN THE SCOPE OF CENELEC. March 2014 REGISTER OF NEW NATIONAL STANDARDIZATION INITIATIVES NOTIFIED UNDER SUBSECTORS IN THE SCOPE OF CENELEC March 2014 Issued on : 04 April 2014 Page 1 Information Procedure on Standards Notifications registered

More information

pyxis u pyxis ua NEW rcgroupairconditioning

pyxis u pyxis ua NEW rcgroupairconditioning Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 44,9 200,0 rcgroupairconditioning R410 C PLTE

More information

Transportation. Distribution

Transportation. Distribution Distribution Transportation Busbar Shielded Systems type: Cast Resin Low Voltage The shielded busbar system, ISOBUSBAR, type IS isolated in polyester or epoxy resin, have been specifically developed for

More information

EXPRESSION OF INTEREST (EOI) FOR. Fire Fighting System (FFS)

EXPRESSION OF INTEREST (EOI) FOR. Fire Fighting System (FFS) EXPRESSION OF INTEREST (EOI) FOR Fire Fighting System (FFS) KWtE-03-PR-EO-ACC-0 Rev01 11 Version: Date: Prepared by: Approved: 01 7/11/18 VMC AMN Page 1 OF 5 1 Project overview ACCIONA s Engineering, Procuring

More information

PolyOne is a global polymer solutions provider with the ability to meet regulatory and product

PolyOne is a global polymer solutions provider with the ability to meet regulatory and product Product Description PolyOne is a global polymer solutions provider with the ability to meet regulatory and product specifications globally and offer the widest range of polymer-specific specialty colorant

More information

BESB Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

BESB Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4 Installation & Operating Manual BESB Box Ventilator USA CAN Product Information... Chapter 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration...

More information

Amendment 3 Metal Cased Skeleton Consumer units for use in Meter Cabinets. Starbreaker

Amendment 3 Metal Cased Skeleton Consumer units for use in Meter Cabinets. Starbreaker Starbreaker mendment 3 Metal Cased Skeleton Consumer units for use in Meter Cabinets SKELETON CONSUMER UNITS FOR USE IN METER CBINETS 17th Edition Wiring Regulations Incorporating mendment No. 3: 2015

More information

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning : Packaged air cooled liquid chillers with free-cooling system for outdoor installation, equipped with screw compressors and axial fans Cooling Capacity: 314 1343 Free-Cooling Capacity: 308 938 GLYCOL

More information

Fire dampers. Type FKA-3.8. For diverse applications

Fire dampers. Type FKA-3.8. For diverse applications . X X testregistrierung Fire dmpers Type with fusible link for 7 C or 95 C For diverse pplictions Rectngulr fire dmper for the isoltion of duct penetrtions between fire comprtments, for mortr-bsed instlltion

More information