135'c " Conduit, 6-#3, 12-#4 Wires Rated-50% 45'c 345'w. 1" Conduit, 3-#4 3.43%VD. 66'c 411'w 4.08%VD. Wires Rated-50% 77'c. 421'w 14 4.
|
|
- Johnathan Ray
- 5 years ago
- Views:
Transcription
1 ,, Panelboard NEM R enclosure. 90 positions 18K breakers Extend existing concrete base per base details. Paint panel very dark green which is close to the panel across the street. Use existing meter. 58' ( Total Runs) pprox 75'. 1" Conduit, 6-#8 " Conduit, 6-#, 18-# 85'c 152'w 'c 120'w 8 2'c 19'w 1" Conduit, -#8.81%VD 2 1 2" Conduit, 6-#, 15-# 1.19%VD 6'c 167'w %VD 1.66%VD 2 1 2" Conduit, 6-#, 12-# 12 66'c 11'w.08%VD 15'c 1" Conduit, -# 22" 1 Conduit, 6-#, 12-# 5'c 5'w 1.%VD Legend and project specific notes and instructions for contractor/bidder: 2" Conduit, 6-#, 6-# ULOCTE has to be used extensively gas, water, sewer, and power. Pull Box, to terminate conduits and crosswire to other conduits as required to receptacles. Size of box to be field determined by boring, electrical contractors, and City Maintenance personnel. #8 and #9 has the 50amp receptacle installed inside, see detail. Do not splice wires by design, however an incidental approved wet splice connector may be made in a not in a. Junction Box, threeway, LB, RB, or other field sized waterproof box with removable sealed access cover for maintenance. Buried, provides and outlet path for receptacle feed. Do not splice wires in a which creates issues in case a wire needs removal by maintenance. Means this particular run is in a 2" PVC electrical rated conduit carrying -# and -# Black Hot wires, 2-#, and 2-# White Neutrals, 2-#10 Green Grounds. ll wires are THWN, Cu, 90Deg. (W - means moisture resistant covering). Shared Neutral wires are not permitted by Code or City. Shared Ground wires are approved if size is adjusted per table and properly terminated with compression lugs (approved for burial) or exothermically welded together. Initial: For Construction /16/18 E, PER REVIEWER'S COMMENTS /29/18 " Conduit, 21-# 2 1 2" Conduit, 18-# 2" Conduit, 12-# 2 1 (One Exists - Unknown Size) 2" Conduit, (-#/0, 2"PVC) 65'c 76'w 25'c 101'w.95%VD 17 68'c, 616'w 1-1" Conduit, -# 2" Conduit, 6-#, 6-# 77'c 21'w 1 9'c 71'w " Conduit, 6-# 77'c 58'w 16.18%VD 2" Conduit, 6-#, -# Wires Rated-70%.68%VD.0%VD 78'c 21'w.18%VD Receptacle CS669, WR (if manufactured), twist interlock, 1-Ph, v, with cover. Same as existing style mounting box. See Details on E2, E. Information: This indicates a conduit run of 78' (+/-), length from tip of conduit at opposite end to end. 21'w (+/-) is length of one wire back to the panelboard. Measurements made from best maps available in utocad and have an accuracy tollerance. The City is not responsible for inaccuracies from this method. Design information:.18% indicates the voltage drop of this circuit to the receptacle considering the wire size and length (21') with the design current of 0 amps. Final voltage is therefore 199vac on a nominal, -wire, vac system. NEC max is 5%. Design information: See NEC table and derating table 10.15(B)(a) for groups of current carrying wires in a single conduit, e.g. # wire listed for 85amps is good for amps for 10 to 20 wires. 2" Conduit, 12-# 210'c 11'w 106'c %VD 1 1 " Conduit, 6-# 17'w.1%VD Coordinate Conduit Run with Danny Jones City of Rock Hill everywhere and at this location particularly. Structures exist here to promote tree growth. 1" Conduit, -# 80'c 97'w 7.9%VD Not to standard scale 100' E1 1 OF Electrical Site Plan
2 18" Main Bkr or Fused Disc. Side, Rear or Inside--if possible without increasing height Connections & CT Can 2'-8" Lugs Sec. 1 Shown dimensions have not been verified but for general information. 8'-8" Sec. 2 See note** Sec. ' NEM R ENCLOSURE WITH DOORS Existing Meter (Side or Rear) 5' ** Existing is a 225 Square D Panel and Breakers feeding existing Receptacles. The City would like to relocate the bus internals and breakers to section with 225 breaker feed from Section 2. If not practical, the breakers of that panel are to be relocated to this section regardless. Shown dimensions are best available at this design stage, contractor will obtain final dimenstions from supplier at construction time. Wiring Details, V.Drop, Conduit, and Distances Initial: For Construction /16/18 E, PER REVIEWER'S COMMENTS /29/18 Extend Pad See E Concrete Pad Existing Pad: See Base Details E Existing Panel 28.5" x 18" GENERL ELECTRICL NOTES: 1. THESE DRWINGS ND ELECTRICL INSTLLTIONS WERE PREPRED ND INSTLLED PER RISER DETILS OUTDOOR 201-NTIONL ELECTRICL CODE ND UTHORITY HVING JURISDICTION (HJ). 2. MRKED EQUIPMENT LOCTIONS RE FOR BEST REFERENCE ND INFORMTION.. PENETRTIONS THROUGH WLLS ND SSEMBLIES SHLL NOT LTER FIRE, WTER, MOISTURE, ND IR CODE RTINGS.. LL MTERILS USED SHLL BE NEW ND LISTED WITH U.S. GENCY SUCH S: UL, MET LBS, ETL, ETC. MRKS SHOWING "CE" ONLY, WITHOUT GENCY MRKS, RE NOT CCEPTBLE. Concrete fiber reinforced box. Size per standard sizes such as 18 x 18",1 x 1", 12 x 1" etc. ~18" deep etc. Same as other Rock Hill sidewalk access covers in place, bolted cover preferred for this application for safety and security. Mark "Danger - High Voltage" Existing Concrete Pavers, or Pine Straw at other locations Gravel top with sand to help drain any water that collects. or Foundation Cable Slack Min Leave some slack in cables in ll Pull Boxes. Water proof NEM R box with 50 receptacle mounted inside. Tool required to open water tight barrier for safety and security. Box marked "Danger--High Voltage." Mount top of box min to soil, Electrical Contractor to best size box. or Foundation Presure treated 6x block of wood or other suitable mounting for WP Box. 5. COMMERCIL PPLICTIONS OF WIRE TYPE "NM" NON-METLIC SHETHED CBLE SHLL NOT BE USED. 6. PNELBORDS ND CIRCUITS SHLL BE PERMNENTLY MRKED WITH NME ND USE. 7. UNLESS OTHERWISE MRKED, CONDUCTORS SHLL BE COPPER, #12 MIN, ND SIZED PER PNELBORD SCHEDULE. 8. PER NEC 110.1, 60 C TBLE IS SHOWN FOR WIRING SIZES 100 ND LESS. FIELD USE OF 75 C WIRE TBLE MY BE USED IF LL TTCHED EQUIPMENT IS MRKED T LEST 75 C. 9. ELECTRICL CONTRCTOR SHLL VERIFY OLD/NEW EQUIPMENT COMPTIBILITY, FURNISH, INSTLL, ND GURNTEE FOR ONE YER LL MTERILS NECESSRY TO COMPLETE THIS SCOPE OF WORK. 10. CONTRCTOR SHLL CONTCT THE DESIGN ENGINEER OF ERRORS OR OMISSIONS. THE ENGINEER SHLL RENDER FINL DECISIONS. 11. CONTRCTOR IS RESPONSIBLE ND SHLL ENFORCE THEIR ELECTRICL WORKER SFETY POLICIES ON SITE. DETIL OF PULL BOXES Esp: 8 ND 9 ON MIN STREET Receptacle Box, Same as existing on site rlington DriBox GPD19B except with Leviton (or equiv) CS669 Twist Lock Receptacle to Receive CS 665C 50mp Twist Lock Plugs. Coordinate location with City of Rock Hill. Supplement box with 1" x~2" unistrut section inside or outside box as necessary for a solid mounting. Contractor to verify receptacle will fit into box. 18" Weatherproof Outlet Cover, Outdoor Plug and Receptacle Protector, UL, Lockable, Extra Duty Compliant, 18-in, Plastic Clear Frost Or Equivalent. To Temporary Consessions Stand 50 Feed. w/ Pine Straw Junction Box or Pull Box (Extends to Surface). If, wire part outside is 18" below grade. Connection To Receptacle 1" Rigid PVC, Coordinate location with City maintenance as necessary no wire splices. Connected Load Schedule Details Typical Ground Mounted Receptacle and Connections E2 2 OF
3 18" Main Bkr or Fused Disc. Side, Rear or Inside--if possible without increasing height Connections & CT Can 2'-8" Lugs Sec. 1 Shown dimensions have not been verified but for general information. 8'-8" Sec. 2 See note** Sec. ' NEM R ENCLOSURE WITH DOORS Existing Meter (Side or Rear) 5' ** Existing is a 225 Square D Panel and Breakers feeding existing Receptacles. The City would like to relocate the bus internals and breakers to section with 225 breaker feed from Section 2. If not practical, the breakers of that panel are to be relocated to this section regardless. Shown dimensions are best available at this design stage, contractor will obtain final dimenstions from supplier at construction time. Wiring Details, V.Drop, Conduit, and Distances Initial: For Construction /19/18 Extend Pad See E Concrete Pad Existing Pad: See Base Details E Existing Panel 28.5" x 18" GENERL ELECTRICL NOTES: 1. THESE DRWINGS ND ELECTRICL INSTLLTIONS WERE PREPRED ND INSTLLED PER 201-NTIONL ELECTRICL CODE ND UTHORITY HVING JURISDICTION (HJ). 2. MRKED EQUIPMENT LOCTIONS RE FOR BEST REFERENCE ND INFORMTION.. PENETRTIONS THROUGH WLLS ND SSEMBLIES SHLL NOT LTER FIRE, WTER, MOISTURE, ND IR CODE RTINGS.. LL MTERILS USED SHLL BE NEW ND LISTED WITH U.S. GENCY SUCH S: UL, MET LBS, ETL, ETC. MRKS SHOWING "CE" ONLY, WITHOUT GENCY MRKS, RE NOT CCEPTBLE. RISER DETILS OUTDOOR 5. COMMERCIL PPLICTIONS OF WIRE TYPE "NM" NON-METLIC SHETHED CBLE SHLL NOT BE USED. 6. PNELBORDS ND CIRCUITS SHLL BE PERMNENTLY MRKED WITH NME ND USE. 7. UNLESS OTHERWISE MRKED, CONDUCTORS SHLL BE COPPER, #12 MIN, ND SIZED PER PNELBORD SCHEDULE. Concrete fiber reinforced box. Size per standard sizes such as 18 x 18",1 x 1", 12 x 1" etc. ~18" deep etc. Same as other Rock Hill sidewalk access covers in place, bolted cover preferred for this application for safety and security. Mark "Danger - High Voltage" Existing Concrete Pavers, or Pine Straw at other locations Gravel top with sand to help drain any water that collects. or Foundation Cable Slack Min Leave some slack in cables in ll Pull Boxes. Water proof NEM R box with 50 receptacle mounted inside. Tool required to open water tight barrier for safety and security. Box marked "Danger--High Voltage." Mount top of box min to soil, Electrical Contractor to best size box. or Foundation Presure treated 6x block of wood or other suitable mounting for WP Box. 8. PER NEC 110.1, 60 C TBLE IS SHOWN FOR WIRING SIZES 100 ND LESS. FIELD USE OF 75 C WIRE TBLE MY BE USED IF LL TTCHED EQUIPMENT IS MRKED T LEST 75 C. 9. ELECTRICL CONTRCTOR SHLL VERIFY OLD/NEW EQUIPMENT COMPTIBILITY, FURNISH, INSTLL, ND GURNTEE FOR ONE YER LL MTERILS NECESSRY TO COMPLETE THIS SCOPE OF WORK. 10. CONTRCTOR SHLL CONTCT THE DESIGN ENGINEER OF ERRORS OR OMISSIONS. THE ENGINEER SHLL RENDER FINL DECISIONS. 11. CONTRCTOR IS RESPONSIBLE ND SHLL ENFORCE THEIR ELECTRICL WORKER SFETY POLICIES ON SITE. DETIL OF PULL BOXES Esp: 8 ND 9 ON MIN STREET Receptacle Box, Same as existing on site rlington DriBox GPD19B except with Leviton (or equiv) CS669 Twist Lock Receptacle to Receive CS 665C 50mp Twist Lock Plugs. Coordinate location with City of Rock Hill. Supplement box with 1" x~2" unistrut section inside or outside box as necessary for a solid mounting. Contractor to verify receptacle will fit into box. 18" Weatherproof Outlet Cover, Outdoor Plug and Receptacle Protector, UL, Lockable, Extra Duty Compliant, 18-in, Plastic Clear Frost Or Equivalent. To Temporary Consessions Stand 50 Feed. w/ Pine Straw Junction Box or Pull Box (Extends to Surface). If, wire part outside is 18" below grade. Connection To Receptacle 1" Rigid PVC, Coordinate location with City maintenance as necessary no wire splices. Connected Load Schedule Details Typical Ground Mounted Receptacle and Connections E2 2 OF
4 /19/18 Initial: For Construction Photos of existing receptacle boxes and existing 225 R Panel to be replaced 2.5" ".5" 28 " 1'-.5" 2" " 2.5 ~ Panel Base Important Information Details Supplemental Information and Details nticipated panelboard base dimensions for bidding. ctual base dimensions depend on quoted panelboard dimensions by Contractor. Base maybe extended from existing base with dowels with the above directions. If old base is too far out of level, shims may be used if not more than 21". Otherwise existing base may not be useable. Extend base (in the length direction) and mount panelboard centered on base. Base shall have grade # rebar, 12" on center square mesh, and " minimum from grade, 2500psi concrete. It shall be 18" deep from grade with a top mounting surface " above grade which is level with landscaping pine straw and a 1" bevel. 1" 2'-2 9'-8" 8.5" E OF
5 Note: Not To Scale. Identified Utility Marks re pproximately Located and re Not To Infer Straight Runs. E OF Existing City Utilities Information E, PER REVIEWER'S COMMENTS Initial: For Construction /29/18 /16/18
Installation Instructions
Installation Instructions Free-Standing Electric Ranges Questions? Call 800.GE.CRES (800.432.2737) or Visit our Website at: ge.com EFORE YOU EGIN Read these instructions completely and carefully. IMPORTNT
More informationELECTRICAL SYMBOLS AND ABBREVIATIONS NOT ALL SYMBOLS, DEVICES OR ABBREVIATIONS MAY BE USED
SYMBOLS AND ABBREVIATIONS ABBREVIATIONS GENERAL NOTES LINE TYPE LEGEND CIRCUITS TELECOMMUNICATION SYSTEM ING EQUIPMENT POWER DEVICES FIRE ALARM SYSTEM NOT ALL SYMBOLS, DEVICES OR ABBREVIATIONS MAY BE USED
More informationM001. Revenue Services ISSUED FOR CONSTRUCTION SEPTEMBER. 2, East State Parkway Schaumburg, Illinois Do Not Scale Drawings
1 T Consultant: NOTES, SYMBOLS & ABBREVIATIONS - MECHANICAL Number Description M001 Vestibule 117 LAN/IT Coffee 115 116 Mail Room 118 114 113 112 Scanning 119 Open Office 101 FIRST FLOOR PLAN - MECHANICAL
More informationCOMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods
1. BASIC ELECTRICAL MATERIALS 1. All conduit and raceway must be 3/4" or larger. Exposed raceway in finished areas shall be in 700 or larger wiremold. Exception: runs to individual devices 10 or less,
More informationTABLE LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS ASHRAE Uncovered Parking Areas. Building Grounds. Walkways 10 feet wide or greater
TABLE 9.4.5 LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS ASHRAE 90.1 Uncovered Parking Areas Parking Lots and drives Building Grounds Walkways less that 10 feet wide Walkways 10 feet wide or greater
More informationCHAPTER 20 SERVICE EQUIPMENT
SERVICE EQUIPMENT CHAPTER 20 SERVICE EQUIPMENT Service equipment includes service cabinets and the equipment and materials necessary for installation. 20.1 Signal Service Cabinet For MnDOT traffic control
More information2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK
PART 1 GENERAL 1.01 SCOPE OF WORK SECTION 27 12 23 FIBER OPTIC DATA NETWORK A. Furnish, install, terminate, and test all fiber optic equipment and cabling necessary for a complete and functional data highway
More informationSECTION ELECTRICAL GENERAL PROVISIONS
PART 1 GENERAL 1.01 SECTION INCLUDES A. General provisions for Electrical Systems B. Wire and cable for 600 volts and less. C. Wiring connectors. D. Electrical tape. E. Heat shrink tubing. F. Wire pulling
More informationRocky Mountain Chapter IAEI Annual Meeting Northglenn, CO March 18-19, 2004
Rocky Mountain Chapter IAEI Annual Meeting Northglenn, CO March 18-19, 2004 1. A 2 PVC conduit was installed in the ground prior to setting a factory manufactured home on the foundation. The required service
More informationSECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices.
SECTION 16470 PANELBOARDS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 09900 - Painting. 2. 16120 - Wire and Cable. 3. 16475 - Overcurrent Protective Devices. 1.02 SYSTEM DESCRIPTION A. Performance
More informationABH BASIN HEATER CONTROLS PACKAGE. engineering data and specifications
BH BSIN HETER CONTROLS PCKGE engineering data and specifications BH Basin Heater Control Package 2 BH DVNCED BSIN HETER CONTROLS The Marley BH basin heater package controls the ON and OFF operation of
More informationBuilding Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS
BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS Building Code compliance is the obligation of design professionals and/or contractors. Plan Review and Inspection Guidelines are intended to be used
More informationMASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc
MASTER JOCKEY PUMP CONTROLLER Model JPCE INSTRUCTION MANUAL C 2018 Master Control Systems, Inc TABLE OF CONTENTS Important Safety Information. Page 3 General Description and Installation.. Page 4 Model
More informationMASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc
MASTER PRESSRE MAINTANENCE CONTROLLER Models PMCE INSTRUCTION MANUAL C 2018 Master Control Systems, Inc TABLE OF CONTENTS Important Safety Information. Page 3 General Description and Installation.. Page
More information2011 and 2014 National Electrical Code Changes Residential Only
2011 and 2014 National Electrical Code Changes Residential Only Sponsored By: and.net Instructor: Fritz Gunther, Chief Electrical Inspector 585-436-4460 www.nyeia.com NEW YORK ELECTRICAL INSPECTION AGENCY
More informationPowerWave 2 Busway System
PowerWave 2 Busway System Guide Specifications (Revision 004, 11/17/2017) 1 GENERAL 1.1 Summary This specification covers the electrical characteristics and general requirements for a continuous opening,
More informationSECTION AUTOMATIC TRANSFER SWITCHES
SECTION 26 36 23 AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. General provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationSUGGESTED SPECIFICATION For Series 300 Manual Transfer Switches (3MTS)
SUGGESTED SPECIFICATION For Series 300 Manual Transfer Switches (3MTS) PART 1 GENERAL 1.01 Scope Furnish and install manual transfer switches (3MTS) with number of poles, amperage, voltage, and withstand
More informationControl Panel. 183 MAX 72 MAX Height of Effluent Line. Maximum Water Level 124 MAX 49 MAX
Gallon MIN SaniTEE 818-B Blower Housing 3700-4500 Gallons [14000-17000 L] Control Panel 1. Blower piping to BioBarrier MBR may not exceed 40 FT [12 m] total length and use 4 elbows maximum per train. For
More informationFor those very small galley kitchens where you
Over-and-Under Refrigerator Freezer Electronic digital control panel Seamless molding djustable spill-proof glass shelves djustable dairy compartment djustable glass shelf and deli drawer djustable door
More informationConsider using this two drawer unit in conjunction
Freezer Drawers Seamless molding Location of serial number Electronic digital control panel Model 700BF Magnetic drawer gaskets Upper freezer storage drawer utomatic ice maker (Model 700BFI) Model 700BFI
More informationVACUUM BREAKER MEDIUM VOLTAGE AUTOMATIC TRANSFER SWITCHES
Part One General 1.01 Scope A. It is the intent of this specification to provide a medium voltage automatic transfer system. B. All components, testing and services specified and required for a complete
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017
SECTION 26 0519 LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions
More informationThe Integrated line of refrigeration is growing literally
Over-and-Under Refrigerator / Freezer Electronic digital control panel Seamless molding djustable spill-proof glass shelves djustable dairy compartment Egg container djustable door shelves Model 736TC
More informationMyFAST 16.0 Plus. Layout. Influent See note 4
NOTES: 1. The air supply line into the FST unit must be secured so as to prevent damage from pipe vibration. 2. The units are supplied with 3" semi-flexible airline connections with stainless steel MPT
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2018
SECTION 26 2913 - ENCLOSED CONTROLLERS GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationA. Connected to the equipment ground B. Bonded to the box C. Connected to nearest water pipe D. Connected to a ground rod
Journeyman and Master Common Exam 2 1 The grounding terminal of a grounding-type receptacle installed in a metal box shall be? A. Connected to the equipment ground B. Bonded to the box C. Connected to
More informationSECTION ELECTRICAL IDENTIFICATION
SECTION 16075 - ELECTRICAL IDENTIFICATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationCT CABINET AND UTILITY METERING WELL AND BOOSTER PUMP CONTROL 12"x12" WIREWAY 200A MCB 200A, 120/208V, 3Ø, 4W BOARD TVSS CIA ALARM 400A, DOUBLE-THROW SWITCH PORTABLE GENERATOR CONNECTION ENCLOSURE EXISTING
More informationB. Shop Drawings: List of legends and description of materials and process used for premarking wall plates.
SECTION 262726 - WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationSECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)
SECTION 26 05 21 PART 1 - GENERAL 1.1 DESCRIPTION This section specifies the furnishing, installation, and connection of the low voltage power and lighting wiring. 1.2 RELATED WORK A. Excavation and backfill
More informationSECTION C. Section Cable Trays for Electrical Systems: Additional identification requirements for cable tray systems.
SECTION 26 0553 PART 1 GENERAL 1.1 SECTION INCLUDES A. Electrical identification requirements. B. Identification nameplates and labels. C. Wire and cable markers. D. Voltage markers. E. Underground warning
More informationInstallation Instructions
Installation Instructions 30 Electric Cooktop JP340, JP350, JP930, JP93, JP938, JP939 If you have questions, call 800.GE.CARES or visit our website at: www.geappliances.com BEFORE YOU BEGIN Read these
More informationInformational Bulletin on Mobile office Units Prepared by Mark Hilbert May 17, 2017
Informational Bulletin on Mobile office Units Prepared by Mark Hilbert May 17, 2017 It has come to the attention of the electrical authorities having jurisdiction (AHJs) at the DOE sites there is inconsistency
More informationFIRE ALARM: BY OTHERS, IF REQUIRED.
x x x x x x OS LIGHTING S FLUORESCENT LIGHT FIXTURE, SEE LIGHT FIXTURE SCHEDULE FOR SIZE AND MOUNTING. FLUORESCENT STRIP LIGHT FIXTURE, SEE LIGHT FIXTURE SCHEDULE FOR SIZE AND MOUNTING. WALL BRACKET FLUORESCENT
More informationGARCIA GALUSKA DESOUSA Consulting Engineers
L#57297 /Page 1/July 21, 2017 ELECTRICAL SYSTEMS NARRATIVE REPORT The following is the Electrical Systems narrative, which defines the scope of work and capacities of the Power and Lighting systems, as
More informationSECTION ISOLATED POWER SYSTEMS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 20 11 ISOLATED POWER SYSTEMS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also, delete any other item or paragraph not applicable to
More informationSECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL
SECTION 16400 AUTOMATIC TRANSFER SWITCHES 1.01 RELATED DOCUMENTS PART 1 - GENERAL A. Drawings and general provisions of Contract, including General Conditions and Division 1 Specification sections, apply
More information8. Multi-Family Residential Buildings
Mu lti-f a mily Re s id e n tia lbu ild in g s 2016 Electric Service Requirements, 3rd Edition Section 8 Section 8 Multi-Family Residential Buildings Directory Page 8.1 General 61 8.2 Maximum Available
More informationMECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 8/10/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions
MECKLENBURG COUNTY Land Use and Environmental Service Agency Code Enforcement 8/10/11 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. Is low voltage cable allowed to be run through drilled
More informationSECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES
PART 1 GENERAL A. The requirements of the Contract, Division 1, and Division 16 apply to work in this Section. 1.01 SECTION INCLUDES A. Lighting and appliance panelboards 1.02 RELATED SECTIONS A. 16475,
More informationA. Product Data: For each electrical identification product indicated. B. Comply with 29 CFR and 29 CFR
September 2012, rev. 00 26 0553 Identification for Electrical Systems PART 1. GENERAL 1.01 Summary A. Section Includes: 1.02 Submittals 1. Identification for raceways. 2. Identification of power and control
More informationFIRE ALARM: BY OTHERS, IF REQUIRED.
x x x x x x OS LIGHTING S FLUORESCENT LIGHT FIXTURE, SEE LIGHT FIXTURE SCHEDULE FOR SIZE AND MOUNTING. CAPITAL LETTER DENOTES TYPE, LOWER CASE LETTER DENOTES SWITCH LEG. FLUORESCENT STRIP LIGHT FIXTURE,
More informationMyFAST 8.0 Plus. Layout
Influent from a prescreening device 1618 SaniTEE Screens emergency overlfow from Sludge Holding Zone Sludge Collection 1015 MIN 400 MIN Lateral Brace by others 246.4 MIN 97 MIN NOTES: 1. The air supply
More informationDishwasher. Installation Manual USA DDN25400X DIN Document Number : _AA_USA/ (17:07)
Dishwasher Installation Manual DDN25400X DIN25400 US Document Number : 15 0630 0100 US/ 02-03-16.(17:07) To prevent accidents, which could cause serious injury or death, as well as machine damage read
More informationCurrentGuard TM. Installation, Operation and Maintenance Manual. CurrentGuardTM. Flush Mount. Surge Protective Devices A00
TM CGFS u r g e P R O T E C T I O N CurrentGuardTM Installation, Operation and Maintenance Manual 750-0098-006 A00 Surge Protective Devices CurrentGuard TM Flush Mount Table of Contents Guide to Installation
More informationDishwasher. Installation Manual USA. FOR MODELS (ADA Height) DWS SS DWS FBI
Dishwasher Installation Manual FOR MODELS (D Height) DWS 54100 SS DWS 54100 FI US Installation Manual For Dishwasher Models DWS 54100 SS DWS 54100 FI To prevent accidents, which could cause serious injury
More informationb. For Clarification: Added Dimming Zone number next to each fixture in Computer Classroom 102.
UNC New East Building D Compliant Elevator DDENDUM NO. CO ID# 6-6-0 Code: 6 Item: Chapel Hill, North Carolina December, 08 Page HUFFMN RCHITECT, P 6 PERHING ROD RLEIGH, NORTH CROLIN 7608 PHONE (99) 70-669
More informationSECTION (16140) - WIRING DEVICES
SECTION 26 27 26 (16140) - WIRING DEVICES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Receptacles, Connectors, Switches, and Finish Plates. B. Related Sections: 1. Section 00 31 13.43 (00370) -
More informationDivision 26 ELECTRICAL TABLE OF CONTENTS
Division 26 ELECTRICAL TABLE OF CONTENTS 26 1000 GENERAL... 33 A. CODE... 3 B. RELATED SECTIONS... 3 C. ABBREVIATIONS... 3 D. DEFINITIONS... 3 E. DRAWING REQUIREMENTS... 3 F. EQUIPMENT SERVICE ACCESS AND
More informationDishwasher Installation Manual
Dishwasher Installation Manual DWT 25502 DWT 25502 SS DWT 25502 W DWT 28500 DWT 28500 W DWT 28500 SS DWT 28500 SSWS DWT 28500 W DWT 56502 FI DWT 56502 SS DWT 58500 DWT 58500 FI DWT 58500 SS DWT 58500 SSWS
More informationFireLock High Pressure Butterfly Valve. System No. Submitted By Spec Sect Para Location Date Approved Date
MEA: 276-99-E CSFM: 7770-0531:113 The Series 766 high pressure butterfly valve features a weatherproof actuator housing approved for indoor or outdoor use. It has been developed for fire pump metering
More information1. Distribution panelboards. 2. Lighting and appliance branch-circuit panelboards. 3. Load centers.
September 2012, rev. 00 26 2416 Panelboards PART 1. GENERAL 1.01 Summary A. Section includes: 1.02 Definitions 1. Distribution panelboards. 2. Lighting and appliance branch-circuit panelboards. 3. Load
More informationPART GENERAL 1.01 SECTION INCLUDES
Specification Number: 26 24 16.06 Product Name: Emergency Lighting Control NQ Circuit Panelboards: 240 Vac, 48 Vdc Maximum SECTION 26 24 16.06 Emergency Lighting Control NQ Circuit Panelboards: 240 Vac,
More informationInstallation Instructions
Installation Instructions 30 uilt-in Trivection Wall Oven JT930, JT980, ZET3038, ZET3058 Questions? all 800.GE.RES (800.432.2737) or Visit our Website at: www.geppliances.com EFORE YOU EGIN Read these
More informationONE- AND TWO-FAMILY DWELLING ELECTRICAL CODE HANDOUT (2015 Michigan Residential Code Effective February 8, 2016)
Cheboygan County Department of Building Safety 870 South Main Street P.O. Box 70 Cheboygan, Michigan 49721 TX: (231) 627-8813 FX: (231) 627-8454 www.cheboygancounty.net Service Entrance ONE- AND TWO-FAMILY
More informationNEC Requirements for Standby Power Systems. New England Building Officials Education Association Annual Conference October 5, 2015
NEC Requirements for Standby Power Systems New England Building Officials Education Association Annual Conference October 5, 2015 Emergency & Standby Power Systems Alternative power sources are utilized
More informationChapter 1 General... 5
About This Textbook...xi About the National Electrical Code...xv About the Authors and Illustrator...xix About the Team...xxi Article 90 Introduction to the National Electrical Code... 1 90.1 Purpose of
More informationInstallation Instructions
Installation Instructions 30 Electric Cooktop JP346, JP356, PP9, PP93, PP94, PP945, PP950 If you have questions, call 800.GE.CARES or visit our website at: ge.com BEFORE YOU BEGIN Read these instructions
More information2009 WESTERN SECTION CODE PANEL QUESTIONS
2009 WESTERN SECTION CODE PANEL QUESTIONS 1. The local inspector red-tagged the temporary wiring for a new store of type III construction because he said Romex wasn t allowed to be run in the open according
More informationSECTION RADIANT-HEATING ELECTRIC CABLES / MATS
SECTION 238313- RADIANT-HEATING ELECTRIC CABLES / MATS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Electric radiant snow melting mats or cables embedded in concrete or asphalt slabs, or embedded under brick
More informationInstallation S19-324D1. Class I, Division 1, Groups C & D Explosion Proof. Emergency Signaling System
Installation S19-324D1 Class I, Division 1, Groups C & D Explosion Proof Emergency Signaling System Table of Contents Pre-Installation Information... 2-3 ssembly of Components...4 Install the Flow Switch
More informationINSTALLATION INSTRUCTIONS
INSTLLTION INSTRUCTIONS BUILT-IN LL REFRIGERTOR/LL FREEZER Retain for Future Reference VIKING RNGE CORPORTION 111 Front Street Greenwood, Mississippi 38930 US (662) 455-1200 IMPORTNT - PLESE RED ND FOLLOW
More informationRV Products Division INSTALLATION INSTRUCTIONS FOR SERIES PACKAGE AIR CONDITIONER
RV Products Division INSTALLATION INSTRUCTIONS FOR 46413 SERIES PACKAGE AIR CONDITIONER 1. WARNINGS IMPORTANT NOTICE These instructions are for the use of qualified individuals specially trained and experienced
More information1. Read all instructions before proceeding with the installation. Improper installation may void warranties.
Panel Installation efore Installing Panel 1. ead all instructions before proceeding with the installation. Improper installation may void warranties. 2. Inspect your order for completeness and inspect
More informationSpecification Status: Released
PGE NO.: 1 OF 5 PIN CONFIGURTION ND DESCRIPTION: Specification Status: Released Pin Configuration (Bottom View of ) (Top View of ) 2 хххх C (Side View of ) Note: 2 is product code хххх is Batch Code P1
More informationInstallation Instructions
Installation Instructions 30 Electric - Radiant Excludes Down-Draft Models If you have questions, call 800.GE.CARES or visit our website at: GEAppliances.com. In Canada, call 800.561.3344 or visit our
More informationDishwasher. Installation Manual USA FOR MODELS
Dishwasher Installation Manual FOR MODELS DWT 23100 DWT 23100 SS DWT 23100 W DWT 24100 DWT 24100 SS DWT 24100 W DWT 24400 SS ULTR DWT 24400 W ULTR DWT 25100 DWT 25100 SS DWT 25100 W DWT 25200 WS DWT 25200
More informationSECTION PANELBOARDS. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.
PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. 1.2 SUMMARY A. This Section includes the
More informationDIVISION 16 ELECTRICAL
DIVISION 16 ELECTRICAL Saratoga Springs / standards / 02-2004 Page - 0 ELECTRICAL SECTION 16060 GROUNDING AND BONDING PART 1 GENERAL 1.01 SECTION INCLUDES A. Grounding electrodes and conductors, equipment
More information136"ElectricCooktop. nstructlons _,00, JP961, JP968, JP969, ZEU769. I Iinstallation. -&WARNING - This appliance must be properly grounded.
I Iinstallation 136"ElectricCooktop nstructlons _,00, JP961, JP968, JP969, ZEU769 I "?-I www.g "If you have EAp plia questions, nces.co m" call 800.GE.CARES or visit our website at: BEFORE YOU BEGIN MATERIALS
More informationArticle by: Ark Tsisserev, Principal, Stantec Consulting Ltd.
Re: CEC 2012 Article by: Ark Tsisserev, Principal, Stantec Consulting Ltd. Conductors Do we have a problem with this? Apparently, we do. However, there is no reason to generalize this problem. Although
More informationELECTRIC DRYER INSTALLATION INSTRUCTIONS
ELECTRIC DRYER INSTLLTION INSTRUCTIONS Para una version de estas instrucciones en español, visite www.whirlpool.com Table of Contents DRYER SFETY... 2 Installation Requirements... 3 Tools and Parts...
More informationCADDY CORPORATION. Utility Distribution Systems
Food Service Equipment Air Systems Utility Distribution Systems page 1 of 2 Equipment Specifications General Specifications Caddy Corporation of America Energy Distribution and Management System, which
More informationENCLOSURE AIR CONDITIONERS
ENCLOSURE IR CONDITIONERS Compact Series 2,000 BTUH Celebrating 20 Years of Excellence Engineered & manufactured to endure the most difficult of environments and applications. ISC air conditioners will
More informationElectricity Unit Notes. Agriculture Mechanics I
Electricity Unit Notes Agriculture Mechanics I Principles of Electricity Electricity is a form of energy that can produce light, heat, magnetism, chemical changes Resistance: tendency of a material to
More informationSurge Protective Devices Installation, Operation and Maintenance Manual. LowProfile Series: 080 and 120
LowProfile Series: 080 and 120 Surge Protective Devices Installation, Operation and Maintenance Manual P.O. Box 3760 Winter Park, FL 32790 USA 1.800.647.1911 www.tpssurge.com LOWPROFILE InstaLLatIOn, OPERatIOn
More informationDo not provide service loops or leave excess wire in J-box. Cut all wire lengths to size sufficient to reach termination without stress or excess.
.... Safety Procedures WRNING Dangerous environment. Highly flammable/explosive fuels and high voltage are present. Failure to observe all safety precautions could result in serious injury or death. Observe
More informationECO I N S T A L L A T I O N M A N U A L
ECO I N S T L L T I O N M N U L CONTENTS! EFORE YOU EGIN SFETY & PRECUTIONS 2-4 FN PLCEMENT 5-6 TOOLS NEEDED 7 IN THE OX 8 PRE-INSTLL CHECKLIST 9 INSTLLTION STEP 1: MOUNTING 10 STEP 2: RETENTION SYSTEM
More informationTitle: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards
Change History Date Description of Change Pages / Sections Modified Change Approver Initials 8/1/17 Updated section on Manufacturers 3 1. 6/15/16 Updated division section from 16120 to 26 05 00, - mgl44
More informationEB-M*-** Midsize Electro-Boiler BL509. EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506. EB-CX-** TS Commercial Electro-Boiler BL508
Electro-HELPS IX Boiler, Submittal Data Sheets These provide the mechanical technical details often required for architects/design engineers, shop drawings, etc. They are also useful in providing additional
More information130"ElectricCooktop. nstructlons _,0, JP355, JP910, JP930, JP940, JP950. I Iinstallation. -&WARNING - This appliance must be properly grounded.
I Iinstallation 130"ElectricCooktop nstructlons _,0, JP355, JP910, JP930, JP940, JP950 I r_ www.geappliances.com",,if you have questions, call 800.GE.CARES or visit our website at: I BEFORE YOU BEGIN MATERIALS
More informationLateral braces. Effluent Collection Pipe. by others. FAST Blowers. Airlines. 8" min. 20cm min. DETAIL A SCALE 1 : 25. Biosolids Port.
Influent MyFST 8.0 BSIC SaniTEE 1618 Screens Settling Zone Treatment Zone Lateral braces Effluent Collection Pipe by others FST Blowers irlines Product Description & Layout MyFST 8.0 BSIC Designed to treat
More informationKidde Nitrogen Inert Gas Clean Agent Fire Suppression System
1. GENERAL 1.1 INTENT OF SPECIFICATIONS A. This specification details the requirements for an engineered inert gas fire suppression system Model Kidde Nitrogen. These requirements, combined with good engineering
More informationSECTION BASIC ELECTRICAL MATERIALS AND METHODS. A. This Section includes basic electrical materials and methods including:
SECTION 16050 BASIC ELECTRICAL MATERIALS AND METHODS PART 1 - GENERAL 1.01 SUMMARY A. This Section includes basic electrical materials and methods including: 1. Conduit, fittings and accessories. 2. Wire,
More informationINSTALLATION INSTRUCTIONS FOR MOUNTING KIT
RV Products Division INSTALLATION INSTRUCTIONS FOR 8330-5501 MOUNTING KIT 8330-752 CONTROL BOX KIT (12 VDC COOL ONLY) 9330B755 CONTROL BOX KIT (12 VDC HEAT/COOL) 8530-750 CONTROL BOX KIT (24 VAC COOL ONLY)
More informationSECTION SOLAR PHOTOVOLTAIC (PV) POWER GENERATION SYSTEM
SECTION 48 14 14 SOLAR PHOTOVOLTAIC (PV) POWER GENERATION SYSTEM PART 1 GENERAL 1.1 SECTION INCLUDES The work of this section consists of furnishing a complete Solar Photovoltaic (PV) Power Generation
More informationUSER INSTRUCTIONS FOR FLANGE IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS
USER INSTRUCTIONS FOR FLANGE IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS APPLICATION INDEECO Explosion proof Electric Immersion Heaters for Hazardous Locations are ccsaus Certified for use in areas (external
More information.4 Do complete installation in accordance with latest Electrical Bulletins of the local inspection authority.
Fitness Facility Addition Page 1 1.1 CODES AND STANDARDS.1 Do complete installation in accordance with the latest edition of the CSA C22.1 as amended by the latest editions of the National Building Code
More informationAllegany College of Maryland ACM Welcome Center M&D Project No
SECTION 26.010 GENERAL PROVISIONS PART 1 - GENERAL 1.1 SCOPE: A. Work under this section shall be subject to the GENERAL CONDITIONS hereinbefore written for the entire work, noting especially the reference
More informationP-16 ENGINEER NO. DATE DESCRIPTION 1 01/19/2016 FOR CONSTRUCTION 2 03/11/2016 REVISION # 2 DRAWN BY: CHECKED BY: DATE: SCALE: DRAWING NUMBER
PRESSIONAL P-16 PRESSIONAL PRESSIONAL PRESSIONAL 1 ONE LINE DIAGRAM 3 EMEGENCY LIGHTING SCHEME 2 FEEDER SCHEDULE PRESSIONAL PRESSIONAL PRESSIONAL PRESSIONAL LOCAL SINGLE POLE SWITCH 3-WAY SWITCH 3-WAY
More informationProduct Specifications 3 Breaker Main Disconnect Panel with Undervoltage Trip
NOVA Energy & Automation Product Specifications 3 Breaker Main Disconnect Panel with Undervoltage Trip Model NEAS-XXXX-G-UVR 03 January 2012 Product Description 1. Standard Applications The Nova 3 Breaker
More informationNOTES X X GENERAL NOTES: architects planners interiors X X 1. EXISTING DEVICES AND EQUIPMENT NOT SHOWN ARE TO REMAIN. X X 2. RETURN ALL LIGHT FIXTURES
GENERL :. EISTING DEVICES ND EQUIPMENT NOT SHOWN RE TO REMIN. 2. RETURN LL LIGHT FITURES REMOVED TO OWNER. FORT WORTH, TES 766 F 87-338-9245 PROJECTOR SCREEN SWITCH HURST, TES 76053 F 87-284-5075 ER 02/7/207
More informationA. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.
SECTION 262416 - PANELBOARDS PART 1 - GENERAL 1.1 SUMMARY A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards. 1.2 PERFORMANCE REQUIREMENTS A. Seismic Performance:
More informationSECTION AUTOMATIC TRANSFER SWITCHES
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 36 23 SPEC WRITER NOTE: Use this section only for NCA projects. Delete between //--// if not applicable to project. Also, delete any other item or paragraph
More informationCPL Series Pedestal Convection Heater
Installation Instructions and RENEWAL PARTS IDENTIFICATION CPL Series Pedestal Convection Heater MODEL CPLAS (H=5-1/2, D=3 ) CAT. LENGTH WATTS/ TOTAL AMPERAGE NO.* L Ft. WATTS 120V 208V 240V 277V 2125
More informationPANELBOARDS & BUILDING DISTRIBUTION
262416 PANELBOARDS & BUILDING DISTRIBUTION PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Distribution panelboards 2. Power panelboards B. Related Sections: 1.02 POLICY 1. CU Standard 260500, Basic
More informationChiller installation, contractor s scope of work:
Chiller installation, contractor s scope of work: See complete DTS O&M Manual for further details Pre-planning: Provide installation surface Either, ground level concrete pad 5 W x 12 L x min 4 depth,
More informationA. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings.
DIVISION 26 ELECTRICAL SECTION 26 27 26 PART 1 GENERAL 1.01 DESCRIPTION A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings. B. Specialty switches and outlets
More informationOne of the more popular models of the Integrated
ll Refrigerator Drawers Seamless molding Removable crisper cover Location of serial number Electronic digital control panel Magnetic drawer gaskets Upper refrigerator storage drawer Front venting with
More information