SMALL PRESSURE CONTROLS (DISC TYPE)

Size: px
Start display at page:

Download "SMALL PRESSURE CONTROLS (DISC TYPE)"

Transcription

1 GENERA DESCRIPTION Control CB series are disc type small pressure controls featuring compact structure and field proven high quality. It is designed to suit modern designed application with its compact and various type of connection styles, such application as air conditioning, automobile industries and others. Type ACB igh & medium pressure range Type CB ow pressure range Type CB igh working pressure Type GCB Dual pressure controls Type TCB Triple pressure controls STANDARD TYPE NUBER SEECTION Type ACB & CB SA PRESSURE CONTROS (DISC TYPE) igh Volume OE Item Type ACB, CB, CB, GCB & TCB U recognized (available upon request) in. ax. ax. ACB 0.7 {7}. {}. {} CB 0. {} 0.7 {7}. {} Contact Functions SPST (igh Cut) SPDT SPSTanual Reset Connections Female Flare /" Solder SPDTanual Reset Female Flare SPST (ow Cut) /" Solder Type ACB Terminal Construction Type ACB Application Type CB Unit: Pa {kgf/cm 2 } Dimension Open 0.0 Water Proof 0.06 Open 0.0 Water Proof Open igh Cut Out Water Proof 0.06 Open Fan Control 0.0 Water Proof ow Cut Out 0.06 Type CB Off Setting On ax. Contact Functions Connections Terminal Construction Application CB 2.0. {2.} {20.} 8.0 {80} SPST ale 0 Direct Coupler igh Working 0.0 Type GCB & TCB Setting ax. Contact Off On Functions GCB ow {2.00.2} ess Than 0.0 {0.} SPST (ow Cut) igh.0.2 {22.0} {6.2.0} SPST (igh Cut) TCB EECTRICA RATINGS Type ACB, CB & CB 0.02 ow {2.00.2} ore Than 0.02 {ore Than 0.2}. {} SPST (ow Cut) ale id..0. {.8.}.20. {2..} (0.29) {()} SPST (ow Cut) igh.0.2 {22.0} (2.) {(26)} {62} SPST (igh Cut) Terminal Connections Construction Application Direct Coupler Dual Controls Triple Controls Category of Ratings Rating Rating T Rating Rated Voltage (V) Power Factor (cos) 2V.AC 20V.AC 2V.DC 2V.AC 20V.AC 2V.DC 2/2V.DC Non-Inductive Current to 0.02 to to 0.02 to 6 to 0.02 to to Inductive Full oad 0.7 Current ocked Rotor 0. to 2 to to to Type GCB & TCB 2V. DC 2.A (2V. DC A) 0.0 { }

2 SA PRESSURE CONTROS igh Volume OE Item Type TB, ETB, TB & FTB GENERA DESCRIPTION Factory set pressure switch designed for use in refrigeration units of quantity production such as room air conditioner (heat pump), packaged air conditioner (heat pump), water chiller etc. With SPDT contact mechanism. odels identified with electrical rating code can be used for minimum 0.02A/2V.AC rating. odels with 0.78 to.96 Pa {8 to 20 kgf/cm 2 } range are also available for TB and FTB. odels with 0.0 Pa { kgf/cm 2 } differential are also available for TB (max. range limit:.27 Pa { kgf/ cm 2 }). Type TB U recognized (available upon request) Type FTB TYPE NUBER SEECTION (SPECIFICATIONS) TB A0 TB A02 TB A0 TB A0 TB A0 TB A06 ETB A0 ETB A02 ETB A0 ETB A0 ETB A0 ETB A06 TB A0 TB A02 TB A0 TB A0 TB A0 TB A06 FTB A0 FTB A02 FTB A0 FTB A0 FTB A0 FTB A06 Application ow igh Factory Setting in. ax. On Off {}.96 {20} Refer to Electrical Ratings Table in the list below {} 0.2 {2.} 2.9 {0} 0.09 to 0.7 {0.6 to.} Automatic operation on pressure decrease and manual reset ower imit 0.29 to 0.9 { to } Upper imit 0.29 to 0.69 { to 7} Automatic operation on pressure increase and manual reset 0.29 {} anual Reset.96 {20} anual Reset 0.96 {2} {} 2. {2} ax. Working. {}. {} Connections Unit: Pa {kgf/cm 2 } Electrical Ratings EECTRICA RATINGS Rated Voltage (V) Non-Inductive Current Inductive Current Non-Inductive Current Inductive Current Power Rating Rating Rating Factor (cos) 2V.AC 20V.AC 2V.AC 20V.AC 2V.AC 20V.AC to 0 to 0 to 0. to to to 0.7 to 2 to 2 0. to 0.02 to to to 8 0. to to 6 to to to 0.7 to 6 0. to to 6 to 6 to 2 0. to to to Full oad C to 6 to 6 to 2 0. to Full oad Terminal ocked Rotor 0. C ocked Rotor 0.

3 CONTACT FUNCTIONS Type TB & TB Type ETB (2 : anual Reset) Type FTB ( : anual Reset) C C 2 C C Common Terminal Close on Increase Close on Decrease : Operating direction on press. increase at igh Press.Side, 2: Operating direction on manual reset Capillary Tube Capillary Tube Dust Protection Cap /" /" Solder Connection is also available upon request. DIENSIONS Type TB 68 Type ETB ax. 2 ax. 0 8 Reset Button Faston Terminal # Type TB ax. 7 Faston Terminal # Type FTB ax ax ax. 2 Faston Terminal # ax. 0 Faston Terminal #20 ax

4 CONTACT FUNCTIONS Type ACB, CB & CB C BUE C C BUE RED RED BACK BACK PRESS. RISING PRESS. RISING PRESS. RISING PRESS. RISING PRESS. RISING Code A Code B Code C Code B w/anual Code C w/anual Type TCB Type GCB igh Press. iddle Press. ow Press. /" Female Flare igh Press. ow Press. : Operating direction on press. increase at igh Press.Side : Operating direction on manual reset /" ale Flare Capillary /" Copper Solder /8" ale PT 7 /" Female Flare Schrader Depressor ex. 2 7/6 20UNF O Ring ex. /8 2UNF mm I.D R /8" 7 0 DIENSIONS Reset Button ex. 7/6 20UNF ex. 7/6 20UNF ex. 7/6 20UNF ex. 7/6 20UNF Type CB Type GCB Type TCB ex. 7/6 20UNF ex. 7/6 20UNF

5 SINGE FUNCTION PRESSURE CONTROS Type SNS & NS GENERA DESCRIPTION For use with fluorinated refrigerants as well as with air and water. (Allowable fluid temp.: 20 to 20 C) Type SNS for universal application. Type NS for high pressure safety cut out. Available drip proof enclosure for marine application or explosion proof enclosure for special application. ounting bracket is supplied as standard. With SPDT contact mechanism. IP with upper lid (option). Ammonia odels: Available upon request. U recognized (available upon request) Type SNS Type NS TYPE NUBER SEECTION (SPECIFICATIONS) Type SNS Automatic Reset Type Unit: Pa {kgf/cm 2 } Factory Setting ax. Working in. ax. in. ax. Off (On) On (Off) SNS C0X 0.06 {0cmg} 0. {} 0.0 {0.} 0.0 {0.} 0. {} 0.02 {0.2} 0.0 {0.} SNS C02X 0.02 {20cmg} 0.2 {2} 0.02 {0.2} 0. {.} 0. {} SNS C0X 0.06 {0cmg} 0. {} 0.0 {0.} 0.0 {0.} 0. {.} {0} 0.2 {2} SNS C0X 0.06 {0cmg} 0. {} 0.0 {0.} 0. {} 0.2 {2} SNS C06X 0.06 {0cmg} 0.6 {6} 0.06 {0.6} 0. {} 0.2 {2} 0. {}. {} SNS C0X 0. {} {0} 0. {} 0. {} 0. {} 0.6 {6} SNS C20X 2 {20} 0.2 {2} 0. {}.2 {2}. {} {0} 0. {} SNS C0X {0} 0. {} {0} 2 {20} 2. {2}. {} SNS CX {0}. {} 0. {}. {} 2. {2} {0}.8 {8} Contact Function 0. Type SNS anual Reset Type Unit: Pa {kgf/cm 2 } Factory Setting ax. Working Contact anual Reset in. ax. Off On Function SNS C02X {20cmg} 0.2 {2} Automatic operation 0.02 {0.2} 0. {} on pressure SNS C06X {0cmg} 0.6 {6} decrease, and 0.2 {2} manual reset. {} 0. 2 SNS C0X2 0. {} {0} manual reset. 2 {20}. {} Based on the terminal connection. Type NS Automatic Reset Type Unit: Pa {kgf/cm 2 } Factory Setting ax. Working Contact in. ax. Off On Function NS C0X 0.8 {8} Based on the terminal connection. {0} 0. to 0. fixed { to fixed} 2 {20}.6 {6}. {} 0.2 Type NS anual Reset Type Unit: Pa {kgf/cm 2 } Factory Setting ax. Working Contact anual Reset in. ax. Off On Function NS C0X 0.8 {8} {0} Based on the terminal connection. Enclosure: IP20 Drip Proof odels: Available upon request. (Refer to Pages 8, 9.) Automatic operation on pressure increase, and manual reset. 2 {20} manual reset. {} 0.2

6 EECTRICA RATINGS CONTACT FUNCTIONS Rated Voltage (V) Power Factor (cos) Non-Inductive Current Inductive Full oad 0.7 Current ocked Rotor 0. 2/20V. AC /" Flare 7/6 20 Thread Standard Refer to Pages, 6 & 2 & Common Terminal Common Terminal Close on Increase Open on Increase Close on Decrease Open on Decrease : Operating direction on press. increase at igh Press. Side, 2: Operating direction on manual reset DIENSIONS Standard odel Type SNS Adjusting Screw Adjusting Screw 80 A Thread ounting ole for Bracket 0 6. Reset Button SNS C0X A B SNS C02X 99. SNS C0X SNS C0X SNS C06X 96. SNS C0X SNS C20X 9.6 SNS C0X SNS CX SNS C02X2 99. SNS C06X2 96. SNS C0X /" B Type NS 9 Adjusting Screw 0.7 Thread ounting ole for Bracket Reset Button /" 7.

7 PRESSURE CONTROS WIT NARROW DIFFERENTIA Type FNS & ANS GENERA DESCRIPTION For use with fluorinated refrigerants as well as with air and water. (Allowable fluid temp.: 20 to 20 C) Type FNS with fixed narrow differential Type ANS with adjustable narrow differential Available drip proof enclosure for marine application or explosion proof enclosure for special application. ounting bracket is supplied as standard. With SPDT contact mechanism. IP with upper lid (option). Type FNS Ammonia models: Available upon request. Type FNS TYPE NUBER SEECTION (SPECIFICATIONS) Type FNS Fixed narrow differential Unit: Pa {kgf/cm 2 } Factory Setting ax. Working in. ax. Fixed Off On FNS C0X 0.06 {0cmg} 0. {} approx. {0.06 approx.} (0.09) {(0.9)} 0.02 {0.2} Type ANS 0. {} FNS C02X 0.02 {20cmg} 0.2 {2} approx. {0.08 approx.} (0.02) {(0.2)} 0.0 {0.} 0. {} FNS C06X FNS C0X 0.06 {0cmg} 0. {} 0.6 {6} {0} 0.02 approx. {0.2 approx.} 0.02 approx. {0.2 approx.} (0.28) {(2.8)} (0.7) {(.7)} 0. {.0} 0.6 {6.0}. {} 0.2 FNS C0X 0. {} {0} 0.2 approx. {.2 approx.} (2.8) {(2.8)} 2. {2}. {} Type ANS Adjustable narrow differential Unit: Pa {kgf/cm 2 } Factory Setting ax. in. ax. Working in. ax. Bottom Top Bottom Top Off On ANS C0XB 0.06 {0cmg} 0. {} {0.07} {0.07} 0.0 {0.} 0.0 {0.} 0.08 {0.8} 0.02 {0.2} 0. {} ANS C0XB 0.02 {20cmg} 0. {} {0.08} 0.0 {0.} 0.08 {0.8} {0.27} 0. {.} 0. {.} {0} ANS C06XB ANS C0XB 0.06 {0cmg} 0. {} 0.6 {6} {0} 0.0 {0.} 0.02 {0.2} 0.08 {0.8} 0.0 {0.} 0.0 {0.} 0.0 {0.} 0.0 {0.} 0.07 {0.7} 0.28 {2.8} 0.7 {.7} 0. {.0} 0.6 {6.0}. {} 0.2 ANS C0XB ANS CXB 0. {} {0} {0}. {} 0.2 {.2} 0.2 {2.0} 0.2 {2.} 0.2 {2.} 0.7 {.7} 0.9 {.9} 2.2 {2.2} 2.82 {28.2} 2. {2} {0}. {}.8 {8} Enclosure: IP20 Drip Proof odels: Available upon request. (Refer to Pages 8, 9.)

8 EECTRICA RATINGS Rated Voltage (V) Power Factor (cos) Non-Inductive Current Inductive Full oad 0.7 Current ocked Rotor 0. 2/20V. AC 2 72 CONTACT FUNCTIONS Common Terminal Close on Increase Close on Decrease : Operating direction on press. increase at igh Press. Side /" Flare Standard Refer to Pages, 6 DIENSIONS Standard odel Type FNS Adjusting Screw Thread ounting ole for Bracket A B FNS C0X FNS C02X 99. FNS C06X 96. FNS C0X FNS C0X A /" B Type ANS 2 80 Adjusting Dial 0.7 Thread ounting ole for Bracket A B ANS C0XB ANS C0XB 99. ANS C06XB 96. ANS C0XB ANS C0XB ANS CXB A 6/" B 6

9 DUA PRESSURE CONTROS Type DNS GENERA DESCRIPTION For use with fluorinated refrigerants as well as with air and water. (Allowable Fluid Temp.: 20 to 20 C) Various contact functions are available. Available drip proof enclosure for marine application or explosion proof enclosure for special application. ounting bracket is supplied as standard. IP with upper lid (option). Ammonia models: Available upon request. U recognized (available upon request) TYPE NUBER SEECTION (SPECIFICATIONS) Automatic Reset Type DNS D0X DNS D06X DNS D60X DNS D606X Side in. ax. in. ax. Factory Setting Off On ax. Working ow Side 0.06 {0cmg} 0. {} 0.0 {0.} 0.2 {2} 0. {} 0.2 {2}. {} igh Side 0.8 {8} {0} Approx. 0. fixed {Approx. fixed} 2 {20}.6 {6}. {} ow Side 0.06 {0cmg} 0.6 {6} 0.06 {0.6} 0. {} 0.2 {2} 0. {}. {} igh Side 0.8 {8} {0} Approx. 0. fixed {Approx. fixed} 2 {20}.6 {6}. {} ow Side 0.06 {0cmg} 0. {} 0.0 {0.} 0.2 {2} 0. {} 0.2 {2}. {} igh Side 0.8 {8} {0} Approx. 0. fixed {Approx. fixed} 2 {20}.6 {6}. {} ow Side 0.06 {0cmg} 0.6 {6} 0.06 {0.6} 0. {} 0.2 {2} 0. {}. {} igh Side 0.8 {8} {0} Approx. 0. fixed {Approx. fixed} 2 {20}.6 {6}. {} Unit: Pa {kgf/cm 2 } Contact Function 0.9 anual Reset Type Side DNS D0X DNS D06X DNS D60X DNS D606X in. ax. in. ax. Factory Setting ax. Working ow Side 0.06 {0cmg} 0. {} 0.0 {0.} 0.2 {2} 0. {} 0.2 {2}. {} igh Side 0.8 {8} {0} Automatic operation on pressure rise, and manual reset. 2 {20} manual reset. {} ow Side 0.06 {0cmg} 0.6 {6} 0.06 {0.6} 0. {} 0.2 {2} 0. {}. {} igh Side 0.8 {8} {0} Automatic operation on pressure rise, and manual reset. 2 {20} manual reset. {} ow Side 0.06 {0cmg} 0. {} 0.0 {0.} 0.2 {2} 0. {} 0.2 {2}. {} igh Side 0.8 {8} {0} Automatic operation on pressure rise, and manual reset. 2 {20} manual reset. {} ow Side 0.06 {0cmg} 0.6 {6} 0.06 {0.6} 0. {} 0.2 {2} 0. {}. {} igh Side 0.8 {8} {0} Automatic operation on pressure decrease, and manual reset. 2 {20} manual reset DNS D606X ow Side 0.06 {0cmg} 0.6 {6} 0.2 {2}. {} Automatic operation on pressure rise, and manual reset. igh Side 0.8 {8} {0} 2 {20}. {} Enclosure: IP20 Drip Proof odels: Available upon request. (Refer to Pages 8, 9.) Off On. {} Unit: Pa {kgf/cm 2 } Contact Function

10 EECTRICA RATINGS Rated Voltage (V) Power Factor (cos) Non-Inductive Current Inductive Full oad 0.7 Current ocked Rotor 0. 2/20V. AC 2 72 CONTACT FUNCTIONS : Operating direction on press. increase at ow Press. Side : Operating direction on press. increase at igh Press. Side : Operating direction on manual reset /" Flare 7/620 Thread Standard Refer to Pages, 6 DIENSIONS Standard odel ow Adjusting Screw ow Adjusting Screw 06 igh Adjusting Screw Reset Button Thread ounting ole for Bracket /"

11 OI PROTECTION CONTROS Type ONS GENERA DESCRIPTION Provides dependable protection against major breakdown on pressure lubricated refrigeration compressors by guarding against low lubrication oil pressure. With manual reset. Built in time delay switch. ounting bracket is supplied as standard. Ammonia models, drip proof models are available upon request. TYPE NUBER SEECTION (SPECIFICATIONS) Unit: Pa {kgf/cm 2 } Timer Specification in. ax. Delay Time(sec.) Timer Voltage Timer Circuit ONS C06XQ ONS C06XQ /200V. AC ONS C06XQ 0 ONS C06XQ ONS C06XQ 90 0/220V. AC ONS C06XQ6 0 ONS C06XQ7 ONS C06XQ8 90 /20V. AC ONS C06XQ9 0 ONS C06XQ0 Standard ONS C06XQ 90 20/20V. AC (SPST) ONS C06XQ2 0 without 00/200V. AC Alarm Contact Connection /" 0. ONS C06XQ ONS C06XQ2 90 ONS C06XQ 0 ONS C06XQ ONS C06XQ 90 0/220V. AC 000mm Capil. ONS C06XQ6 0 Tube with /" ONS C06XQ7 ONS C06XQ8 90 /20V. AC 0.62 ONS C06XQ9 0 Approx. ONS C06XQ0 0.0 ONS C06XQ 90 20/20V. AC fixed ONS C06XQ ONS C06XQ2 {0.} {.} Approx. ONS C06XQ ONS C06XQ27 fixed 0 00/200V. AC ONS C06XQ28 ONS C06XQ /220V. AC ONS C06XQ0 0 ONS C06XQ /" 0. ONS C06XQ2 90 /20V. AC ONS C06XQ 0 ONS C06XQ ONS C06XQ 90 20/20V. AC With Alarm ONS C06XQ6 0 Contact ONS C06XQ2 (SPDT) ONS C06XQ /200V. AC ONS C06XQ27 0 ONS C06XQ28 ONS C06XQ /220V. AC 000mm Capil. ONS C06XQ0 0 Tube with /" ONS C06XQ ONS C06XQ2 90 /20V. AC 0.62 ONS C06XQ 0 ONS C06XQ ONS C06XQ 90 20/20V. AC ONS C06XQ6 0 ax. Working :. Pa { kgf/cm 2 } imit of Diff. pp:. Pa { kgf/cm 2 }, p represents oil pump discharge pressure and p crank case pressure. Enclosure: IP20 Drip Proof Construction type is available upon request. Please, add W into the catalog number on ordering; for example, ONSC06XWQ0. Ammonia Application type ONSC06XN is also available upon request ( to be 0.06 Pa {0.6 kgf/cm 2 } fixed). 9

12 EECTRICA RATINGS Rated Voltage. (V) Power Factor (cos) 2/20 V. AC Non-Inductive Current. Inductive Full oad 0.7 Current ocked Rotor 0. 0 CONTACT FUNCTIONS eater Circuit 00V otor Circuit 2 eater 200V : Operating direction of pressure increase c: Operating direction of timer when energized : Operating direction of manual reset ( : Alarm Contact provided with a lead wire approx. ).00mm with a soldered terminal. /" Flare 7/6 20 Thread Standard Refer to Pages, 6 Common Terminal 00 eater Circuit 00V Power Supply Terminal V Power Supply Terminal Open on Decrease of Difference 2 otor Circuit ain Contact Alarm Contact 0/220V. AC, 20/20V. AC etc. available DIENSIONS ead wire for Alarm Contact /" Reset Button Thread ounting ole for Bracket 9. 20

13 Type WNS GENERA DESCRIPTION DIFFERENTIA PRESSURE CONTROS For use on any application where the relationship between two pressure is critical to proper equipment operation. With SPDT contact mechanism. Available drip proof enclosure for marine application or explosion proof enclosure for special application. ounting bracket is supplied as standard. Ammonia models are also available. U recognized (available upon request) TYPE NUBER SEECTION (SPECIFICATIONS) For water, air and fluorinated refrigerant. Unit: Pa {kgf/cm 2 } Factory Setting imit of ax. Working Press. in. ax. in. ax. Off On (PP) WNS C02X 0.0 {0.} 0.2 {2} 0.0 {0.} 0. {.} 0.0 {0.} 0.02 {0.2} 0. {} 0. {} 0. WNS C06X 0.0 {0.} 0. {.} 0.0 {0.} 0.2 {2.} 0. {.0} 0.0 {0.}. {}. {} Allowable Fluid Temp.: 20 to 20 C P...igh Side Press. P...ow Side Press. Enclosure: IP20 Drip proof models: Available upon request. (Refer to Pages 8, 9.) EECTRICA RATINGS Rated Voltage. (V) Power Factor (cos) 2/20 V. AC Non-Inductive Current 2 Inductive Full oad 0.7 Current ocked Rotor CONTACT FUNCTIONS Common Terminal 2 Close on Increase Close on Decrease : Operating direction on press. increase at igh Press. Side DIENSIONS A 80 /" Flare 7/6 20 Thread Standard Refer to Pages, B 6. D 20. C 2 6/" A B C D WNS C02X WNS C06X Thread ounting ole for Bracket 2

Dual Pressure Controls

Dual Pressure Controls PRESSURE CONTROLS Dual Pressure Reset Hp/Lp Range Differential kpa kpa Ranco Dual Pressure G0048 017-8711* -30 to 700 700 to 3000 62 to 393 350 bar fixed G0056 017-8701 -30 to 700 700 to 3000 62 to 393

More information

PRESSURE REGULATING VALVES

PRESSURE REGULATING VALVES Type EPR PRESSURE REGUATING VAVES Evaporating pressure regulating valves Direct operated, 2-way valves designed for maintaining suitable evaporating pressure in refrigeration. Fitted at te evaporator outlet

More information

Fan speed controller Type Saginomiya XGE

Fan speed controller Type Saginomiya XGE Data sheet Fan speed controller Type Saginomiya Fan speed controller stabilizes condensing pressure by changing condenser s fan speed. The controller reduces fan noise and saves energy in low ambient conditions.

More information

TEMPERATURE & PRESSURE CONTROLS

TEMPERATURE & PRESSURE CONTROLS TEMPERATURE & PRESSURE CONTROLS RANCO LUBE OIL PROTECTION CONTROLS These lube oil protection controls guard pressure-lubricated refrigeration compressors against major damage due to loss of oil pressure.

More information

Pressure switch KPU. Data sheet

Pressure switch KPU. Data sheet Data sheet Pressure switch KPU The KPU switches are designed for use in refrigeration and air-conditioning systems to protect the systems from excessively low suction or too high discharge. They can also

More information

y Small dimensions. Easy to install in refrigerated counters or cold rooms

y Small dimensions. Easy to install in refrigerated counters or cold rooms MAKING MODERN LIVING POSSIBLE Data sheet Thermostat Type KP The KP Thermostats are temperaturecontrolled electrical switches. All KP Thermostats have a single pole double throw (SPDT) changeover switch.

More information

Thermostats type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Thermostats type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet Thermostats type KPU REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction... 3 Features... 3 Approvals... 3 Technical data... 3 Regulating ranges... 4 Ordering... 4 Contact systems...

More information

FSW SECTION. Product guide. Thermostats, Pressure Switches & Fan Speed Controls. E SECTION For more information visit

FSW SECTION. Product guide. Thermostats, Pressure Switches & Fan Speed Controls. E SECTION For more information visit FSW Product guide E SECTION Thermostats, Pressure Switches & Fan Speed Controls. 63 64 Head Office 01543 437 010 Danfoss Service Thermostat Kits TYPE TO SUIT E005 NO-1 Refrigerator E006 NO-2 Refrigerator

More information

Pressure-Resistant and Explosion-Proof Electric Contact Pressure Gauges and Pressure Switches

Pressure-Resistant and Explosion-Proof Electric Contact Pressure Gauges and Pressure Switches CATALOG No. 3150 MODEL No. AdC No. AdS Pressure-Resistant and Explosion-Proof Electric Contact Pressure Gauges and Pressure Switches AdC-Type Pressure Gauges with Contact AdC-WType Differential Pressure

More information

INSTALLATION, OPERATION, SERVICE & PARTS SUPPLEMENT for

INSTALLATION, OPERATION, SERVICE & PARTS SUPPLEMENT for T-333 Manual INSTALLATION, OPERATION, SERVICE & PARTS SUPPLEMENT for Rooftop Energy Storage Systems (ESS) AIR COOLING UNIT 77-62186-00 THRU -04 & 77-62203-00 T-333 REV. 03/2012 2012 Mobile Climate Control

More information

ProRadiant Controls, Valves and Actuators

ProRadiant Controls, Valves and Actuators 214 Controls, Valves and Actuators Stock Controls, Valves and Actuators BASIC HEATING CONTROL Features: Modulating mixing valve control Supply temperature high limit Seasonal pump activation Boiler activation

More information

59T, 66T Series Electric Water Heater Controls

59T, 66T Series Electric Water Heater Controls , 66T Series Electric Water Heater Controls Snap-Action Bimetal Discs in Both Controls The and 66T series controls are designed to meet the high electrical capacity requirements of electric water heaters.

More information

XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation

XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation The Series convection heater, with ratings up to 5000 watts, is designed for heating spaces where explosive substances are or may be present. The is available with either C CSA US or CE/ ATEX approvals.

More information

Convection Heaters. Type XB. Product Description. Selection of Temperature Code. Construction and Installation. Special Wattage and Lengths

Convection Heaters. Type XB. Product Description. Selection of Temperature Code. Construction and Installation. Special Wattage and Lengths Product Description The XB, with ratings up to 5000 watts, is designed for heating spaces where explosive substances are or may be present. The XB is available with either CSA C/US or CE/ATEX approvals.

More information

INDEX APPLIANCE GAS WATER HEATER CONTROLS 150 ELECTRIC WATER HEATER THERMOSTATS 151 SNAP DISC CONTROLS/LIMITS/SWITCHES 152 GAS DRYER VALVES 153

INDEX APPLIANCE GAS WATER HEATER CONTROLS 150 ELECTRIC WATER HEATER THERMOSTATS 151 SNAP DISC CONTROLS/LIMITS/SWITCHES 152 GAS DRYER VALVES 153 INDEX GAS WATER HEATER CONTROLS 150 ELECTRIC WATER HEATER THERMOSTATS 151 SNAP DISC CONTROLS/LIMITS/SWITCHES 152 Model(s) Page(s) Flush Mount Fan/Limit/Attic Fan Control... 152 GAS DRYER VALVES 153 Model(s)

More information

Instructions OP-LPHM & OP-MPHM OP-LPHM & OP-MPHM & OP-MPUM & OP-MPGM034

Instructions OP-LPHM & OP-MPHM OP-LPHM & OP-MPHM & OP-MPUM & OP-MPGM034 OP-PH018-026 & OP-PH007-010-012-015-018 OP-PH048-068 & OP-PH026-034 & OP-P034-046 & OP-PG034 1 FRCC.EI.019.A2. Danfoss Commercial Compressors 06/12 OP-PH096-136 & OP-P068-080-107 OP-PH215-271 & OP-P125-162

More information

MR3CCUHV Temperature/Defrost Control

MR3CCUHV Temperature/Defrost Control Master Catalog 125 Temperature Controls Section A Product/Technical Bulletin Issue Date 0401 MR3CCUHV Temperature/Defrost Control The MR3CCUHV Temperature/Defrost Control is designed to control the temperature

More information

ADJUSTABLE CONTROLS WHO WE SERVE

ADJUSTABLE CONTROLS WHO WE SERVE FIXED SETTING SELECTION GUIDE FOR UtTHMM AT ADJUSTABLE DEPENDABLE TEMPERATURE Engineering of Controls for Volume Production Applications. SPECIAL PURPOSE EMSiSOM EL'CTJC THERM O-DISC DIVISION jess IVAÎBUMGEM

More information

TC-5231 Series, TC-5232, & TC-5241 Series

TC-5231 Series, TC-5232, & TC-5241 Series TC-5231 Series, TC-5232, & TC-5241 Series Low Temperature Thermostats General Instructions Application The TC-5231, TC-5232, and TC-5241 low temperature thermostats are used to control temperature in air

More information

A11 Series Low Temperature Cutout Controls

A11 Series Low Temperature Cutout Controls Code No. LIT-1927005 A11 Series Low Temperature Cutout Controls A11 Series Low Temperature Cutout Controls are available with single-pole, single-throw SPST or single-pole, double-throw SPDT contact action.

More information

ATEX. Tough controls for tough environments. ia.danfoss.com. Brochure Controls. Danfoss controls - designed and approved for hazardous areas

ATEX. Tough controls for tough environments. ia.danfoss.com. Brochure Controls. Danfoss controls - designed and approved for hazardous areas Brochure Controls Tough controls for tough environments Danfoss controls - designed and approved for hazardous areas ATEX approved program ia.danfoss.com Danfoss controls tailored for use in hazardous

More information

Single pressure controls for Refrigeration, Air-conditioning and Heatpump applications

Single pressure controls for Refrigeration, Air-conditioning and Heatpump applications Series P77 Single pressure controls for Refrigeration, Air-conditioning and Heatpump applications Product bulletin These pressure controls are designed for use in a variety of applications involving refrigeration

More information

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE Table of Contents PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE # Electric Room Comfort Controller NEW! RDY2000 Room Comfort Controller RDY 129-905 D-3 Electric for Specialized Applications Surface

More information

36T. Bimetal Disc Controls & Limits. Introduction

36T. Bimetal Disc Controls & Limits. Introduction Introduction 36T 36T Auto Reset Bimetal Control: The 36T auto reset control from ThermODisc offers proven reliability in a compact, versatile, costeffective design. The snap action of the bimetal disc

More information

49 Danfoss Thermostat Kits Ranco Varifix Kits

49 Danfoss Thermostat Kits Ranco Varifix Kits Danfoss Thermostat Kits Code Type To Suit E005 NO-1 Kit Refrigerator E006 NO-2 Refrigerator Push/Defrost E007 NO-3 Fridge Freezer/Larder Fridge E008 NO-4 Absorption Refrigerator E009 NO-5 Freezer E010

More information

Refrigeration and Air Conditioning Technical leaflet. Electronic controller EKC 201 and EKC 301

Refrigeration and Air Conditioning Technical leaflet. Electronic controller EKC 201 and EKC 301 Refrigeration and Air Conditioning Technical leaflet Electronic controller EKC 201 and EKC 301 RC.5L.A1.02 RC.5L.A2.02 09-1998 Introduction EKC 201 and 301 are used for temperature control compressor control

More information

59T, 66T Series Electric Water Heater Controls

59T, 66T Series Electric Water Heater Controls , 66T Series Electric Water Heater Controls 8 Snap-Action Bimetal Discs in Both Controls The and 66T series controls are designed to meet the high electrical capacity requirements of electric water heaters.

More information

Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s)

Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) INDEX UNIVERSAL ELECTRONIC CONTACTOR UPGRADE SURESWITCH 79 Description Model(s) Page(s) SureSwitch... 49P11-843... 79 CONTACTORS 80 82 Description Model(s) Page(s) 1 Pole... 94-388 Thru 94-395... 80 2

More information

Aquastats. Aquatrol Indoor/Outdoor Control. Automatic Changeover Switch 16/05/08

Aquastats. Aquatrol Indoor/Outdoor Control. Automatic Changeover Switch 16/05/08 16/05/08 Aquatrol Indoor/Outdoor Control B3 Adjustable settings for boiler maximum temperature, boiler minimum temperature and outdoor low (design) temperature Selectable Warm Weather Shut Down (WWSD)

More information

Thermostat KPU. Data sheet

Thermostat KPU. Data sheet Data sheet Thermostat KPU The KPU Thermostats are temperature controlled electrical switches, which are applied for regulation and safety monitoring of refrigeration and air conditioning systems. KPU sensors

More information

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 5200 CAT Detection of flammable gases and vapours Dräger Polytron 5200 CAT Detection of flammable gases and vapours The Dräger Polytron 5200 CAT is a cost-effective explosion-proof transmitter for the detection of flammable gases in the lower explosion

More information

Flow Switches. Series VHS, VKS, VH

Flow Switches. Series VHS, VKS, VH Flow Switches Series VHS, VKS, VH Reliable - Safe - Proven! Our tried-and-tested fl ow monitoring switches for liquids are used for two basic purposes: To ensure a minimum fl ow rate, e.g. of cooling water

More information

Sealed Type Liquid Line and Suction Line Specifications

Sealed Type Liquid Line and Suction Line Specifications CATALOG 0 Page,, 4a, 404A, 407C, 40A, 0, 07 Also Compatible with Refrigerants, 4,, 40A & B, 40A & B, 408A, 409A The universal acceptance of the Catch-All Filter-Drier is due to its unique molded porous

More information

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack Master Catalog 125 Temperature Controls Section A Product/Technical Bulletin Issue Date 1098 MR4PMUHV Electronic Temperature/Defrost Control with Relay Pack The MR series temperature controls are designed

More information

RESIDENTIAL & COMMERCIAL AIR CONDITIONER

RESIDENTIAL & COMMERCIAL AIR CONDITIONER RESIDENTIAL & COMMERCIAL AIR CONDITIONER Type UKV ELECTRONIC Capacity: 2.9 to 11.1 U.S.R.T. (R22) 2.3 to 8.7 U.S.R.T. (R134a) 2.1 to 7.8 U.S.R.T. (R404A) 3.0 to 11.4 U.S.R.T. (R407C) 3.4 to 13.1 U.S.R.T.

More information

Temperature & Humidity Controllers

Temperature & Humidity Controllers Electromechanical Temperature Controls T631 Air witch Controller Air witch Controller with heavy-duty corrosion resistant steel case. uitable for lift motor rooms, farm storage areas etc. Line voltage

More information

SERVICE MANUAL FOR 6636A & 6636B SERIES TWO TON HIGH EFFICIENCY PACKAGED AIR CONDITIONERS

SERVICE MANUAL FOR 6636A & 6636B SERIES TWO TON HIGH EFFICIENCY PACKAGED AIR CONDITIONERS SERVICE MANUAL FOR 6636A & 6636B SERIES TWO TON HIGH EFFICIENCY PACKAGED AIR CONDITIONERS TABLE OF CONTENTS 1. Warnings & Component Match-Up............................................ 2 2. Unit Specifications..........................................................

More information

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 5100 EC Detection of toxic gases and vapors Dräger Polytron 5100 EC Detection of toxic gases and vapors The Dräger Polytron 5100 EC is a cost-effective explosion proof transmitter for the detection of toxic gases or oxygen. It uses a high performance

More information

270XT Freeze Protection, IP30

270XT Freeze Protection, IP30 270XT Freeze Protection, IP30 Sensing element is 3 or 6 meters long to permit attaching across the surface of a coil to guard against freezing at any point. When any 30 cm or more of this element senses

More information

MC4000 Series Advanced Solid State Dual Unit Lead/Lag Controller with Ethernet Remote Communication Option

MC4000 Series Advanced Solid State Dual Unit Lead/Lag Controller with Ethernet Remote Communication Option MC4000 Series Advanced Solid State Dual Unit Lead/Lag Controller with Ethernet Remote Communication Option The MC4000 has 2 stages of cooling control available for each connected air conditioner. It is

More information

Ultrasonic Point Level Switches

Ultrasonic Point Level Switches see more at SORInc.com Request Quote Ultrasonic Point Level Switches Ultrasonic point level switches are a cost-effective solution for your applications. Installation requires mounting the sensor (threaded

More information

RA15/6T & TB Conversion Valve

RA15/6T & TB Conversion Valve Applications: continue on. This provides continuous flow, but inherent to series piping the supply water temperature will decrease as it flows through the system and when it mixes with return water from

More information

For Technical Service Telephone Facsimile

For Technical Service Telephone Facsimile Customer Toolbox for 24/7 Real Time Information and Support This secure site enables you access to track order status, accounts receivable, pricing, invoicing, sales tools, online literature orders, training

More information

Commercial Refrigeration Catalog

Commercial Refrigeration Catalog Commercial Refrigeration Catalog Table of Contents: Introduction 3 Eliwell EWPlus 4 Paragon Defrost Controls 6 Ranco Temperature Controls 9 Ranco Pressure Controls 13 The brands you trust, the products

More information

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624 REVISED EDITION-A Models MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE

More information

Powers Controls ET 134 Low Temperature Detection Thermostat

Powers Controls ET 134 Low Temperature Detection Thermostat Document No. 155-115P25 ET 134-20 Powers Controls ET 134 Low Temperature Detection Thermostat Description Features Product Numbers The Electric Low Temperature Detection Thermostat is a remote bulb instrument

More information

Product Data. Features/Benefits. 07DA, DB 07EA, EB, ED Condensing Units. 06D, 06E Compressors. 3 to 40 Nominal Tons

Product Data. Features/Benefits. 07DA, DB 07EA, EB, ED Condensing Units. 06D, 06E Compressors. 3 to 40 Nominal Tons Product Data 07DA, DB 07EA, EB, ED Condensing Units 3 to 40 Nominal Tons 06D, 06E Compressors An excellent choice for your built-up system Carrier 07 Series condensing units built for the engineer who

More information

INTRODUCTION / TABLE OF CONTENTS

INTRODUCTION / TABLE OF CONTENTS 1 2 INTRODUCTION / TABLE OF CONTENTS Step One The LVCN 20 and LVCN 100 Series are general purpose level controllers offered in two configurations for pump and valve control. The LVCN 100 Series features

More information

Series P215LR/BR Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

Series P215LR/BR Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter) PSC9713 European Refrigeration Controls Catalogue Catalog Section 4 Product Bulletin Series Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression

More information

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Dräger Polytron 8200 CAT Detection of flammable gases and vapors Dräger Polytron 8200 CAT Detection of flammable gases and vapors The Dräger Polytron 8200 CAT is an advanced explosion proof transmitter for the detection of flammable gases in the lower explosion limit

More information

Thermostatic Radiator Valves (Caleffi)

Thermostatic Radiator Valves (Caleffi) 02/09/16 B46 Thermostatic Radiator Valves (Caleffi) Thermostatic Control Heads Thermostatic control head fits radiator valves Set point locking mechanism Range stop adjustment Built-in sensor with liquid-filled

More information

Ultrasonic Switches. Features & Benefits

Ultrasonic Switches. Features & Benefits Why use an ultrasonic switch over other level technologies? Depending upon your application, there may be three or four technologies equally suited for your application; however; only one will be the best

More information

Description. Applications

Description. Applications CVEP PDS CVEP Convection for Hazardous Heater For Locations Hazardous Locations Convection Heater 1.8 to 9.0kW (T-2A) 280 C (536 F) 1.6 to 4.0kW (T-3A) 180 C (356 F) 1.8 to 9.0kW (T-2) 1.8 300 C to 9.0kW

More information

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 5200 CAT Detection of flammable gases and vapours Dräger Polytron 5200 CAT Detection of flammable gases and vapours The Dräger Polytron 5200 CAT is a cost-effective explosion-proof transmitter for the detection of flammable gases in the lower explosion

More information

Series A28 Two stage Thermostats. Feature and Benefits

Series A28 Two stage Thermostats. Feature and Benefits PSC9626 European Refrigeration Controls Catalogue Catalog Section 1 Product Bulletin A28 Series A28 Two stage Thermostats I ntroduction These thermostats are designed for various types of heating, cooling,

More information

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC Revision D: MUFZ-KJ25VE - E2, ER2, ET2, MUFZ- KJ35VE - E2, ER2, ET2 and MUFZ- KJ50VE - E2, ER2, ET2 have been added. Please void OBH667 REVISED EDITION-C. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A.

More information

temperature Controllers

temperature Controllers temperature Controllers Bulb and Capillary Thermostats Thermostat Styles and Selection Construction Characteristics This type of control operates by expansion and contraction of a liquid in response to

More information

MULTI INVERTER SERIE H6M

MULTI INVERTER SERIE H6M ULTI INVERTER SERIE H6 Service manual www.mundoclima.com Thank you very much for purchasing our products. Please read this manual carefully before installing and using the unit. L25 to L257 English TENTS

More information

Paddle Flow Switch. Pressure Control Flow Switch

Paddle Flow Switch. Pressure Control Flow Switch Paddle Flow Switch GE-311 Plastic Paddle Flow Switch GE-312 Plastic Flow Switch GE-313 PETF Plastic Flow Switch GE-314 Stainless Steel Flow Switch GE-315 Adjustable Flow Switch GE-316 Brass Paddle Flow

More information

RA 2000 Series RA 15/6T & TB Conversion Valve

RA 2000 Series RA 15/6T & TB Conversion Valve RA 2000 Series RA 15/6T & TB Conversion Valve Applications: RA15/6T Internal bypass allowing for series piping to the radiators/baseboards. This series piping provides continuous flow but the supply water

More information

The Sub-Mini Hermet. OEM Pressure Switches Sub-Mini-Hermet and Omni

The Sub-Mini Hermet. OEM Pressure Switches Sub-Mini-Hermet and Omni OEM Pressure Sub-Mini-Hermet and Omni Factory Set Sub-Mini-Hermet The Sub-Mini Hermet has the ability to be externally adjusted without disconnecting electrical service or tamperproof. These field mounted

More information

Pushbutton Switches. Nylon. Specifications. Heavy Duty, Metal Plunger. Specifications S13 S12

Pushbutton Switches. Nylon. Specifications. Heavy Duty, Metal Plunger. Specifications S13 S12 Nylon S13.250 (6.35).375 (9.35) Dia Heavy Duty 6 Wire Leads Both Bushing & Bracket are Made of Nylon.565 (14.35) 1.000 (25.4).250 (6.35) Travel.540 (13.72) Dia.776 (19.71) 1.120 (28.45) 1.308 (33.22).540

More information

Cost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500

Cost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500 embrane Air Dryer Possible to easily supply dry air using the hollow fiber membrane! Purge air flow rate (L/min [ANR]) 18 16 14 12 8 6 4 IDGA..5 1. Variations Non-fluorocarbon Energy saving IDGA Inlet

More information

PROFESSIONAL - SSE. Stainless steel interior and exterior (with galvanized back and bottom)

PROFESSIONAL - SSE. Stainless steel interior and exterior (with galvanized back and bottom) PROFESSIONAL SERIES PROFESSIONAL - SSE PROFESSIONAL - SSE PROFESSIONAL - SSE Stainless steel interior and exterior (with galvanized back and bottom) Innovative variable speed compressor with adaptive control

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CU-3KE19NBU CU-4KE24NBU CU-4KE31NBU DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 19,100 BTU/h,200 BTU/h 30,600 BTU/h Outdoor Model No. CU-3KE19NBU CU-4KE24NBU

More information

Chilled Water system

Chilled Water system Chilled Water system Introduction For large installations the Condenser, Evaporator, Compressor and Expansion device can be purchased as a package unit, known as a Chiller. The usual package consists of

More information

Replacement Parts List For Models COS-20G

Replacement Parts List For Models COS-20G Replacement Parts List For Models COS-20G (Ovens with s/n HP & HT) Contents: Page # Electrical Compartment:Contactors,Steam Generator,Thermostats 2-5 Oven Interior: 5 Bottom Section: Gas, Plumbing Components

More information

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC Revision E: MUZ-FH25VE- E4, ER4, ET3, MUZ- FH35VE- E3, ER3, ET3 and MUZ- FH50VE- E2, ER2, ET2 have been added. Please void OBH624 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624

More information

A.YITE GROUP (Hongkong & Shanghai)

A.YITE GROUP (Hongkong & Shanghai) In this page, you will find common paddle flow switch, differential pressure flow switch, thermal flow switch, Flow Sensor Paddle Flow Switch FS-01 FDA Flow Switch G1/4 GE-311 Plastic Paddle Flow Switch

More information

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm General Description & Applications The TCA-9102 Series Temperature Controller with Alarm offers a versatile solution for a

More information

Series A36 3- and 4 Stage Thermostats for Refrigeration, Cooling, Heating, Ventilation and Air-conditioning. Feature and Benefits

Series A36 3- and 4 Stage Thermostats for Refrigeration, Cooling, Heating, Ventilation and Air-conditioning. Feature and Benefits PSC966 European Refrigeration Controls Catalogue Catalog Section Product Bulletin A6 Series A6 - and 4 Stage Thermostats for Refrigeration, Cooling, Heating, Ventilation and Air-conditioning Introduction

More information

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. Models MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 Indoor unit service manual MSZ-DM VA Series (OBH750) CONTENTS 1. TECHNICAL CHANGES 2 2. PART NAMES

More information

3NT SERIES FIXED TEMPERATURE THERMOSTATS Introduction

3NT SERIES FIXED TEMPERATURE THERMOSTATS Introduction 3NT SERIES FIXED TEMPERATURE THERMOSTATS Introduction Automatic reset thermostat designed to meet your specific application requirements. Its patented and tamper proof snap action bi-metal disc provides

More information

INSTRUCTION MANUAL FLOAT TYPE LEVEL SWITCHES HITROL CO., LTD.

INSTRUCTION MANUAL FLOAT TYPE LEVEL SWITCHES HITROL CO., LTD. HITROL CO., LTD. HEAD OFFICE.FACTORY.R&D INSTITUDE HITROL CO., LTD 141, Palhakgol-road, Jori-eup Paju-si, Gyeonggi-do, Korea TEL. : (00)-82-31-950-9700 FAX. : (00)-82-31-943-5600 www.hitrol.com INSTRUCTION

More information

Two-Channel Gas Controller

Two-Channel Gas Controller Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously

More information

DUAL VOLTAGE ICE BOX CONVERSION SYSTEM 120 VOLTS A.C. & 12/24 VOLTS D.C. MODELS: SCQT-4408F-U1-L SCQT-4408F-U1-I OWNER'S GUIDE

DUAL VOLTAGE ICE BOX CONVERSION SYSTEM 120 VOLTS A.C. & 12/24 VOLTS D.C. MODELS: SCQT-4408F-U1-L SCQT-4408F-U1-I OWNER'S GUIDE DUAL VOLTAGE ICE BOX CONVERSION SYSTEM 120 VOLTS A.C. & 12/24 VOLTS D.C. MODELS: SCQT-4408F-U1-L SCQT-4408F-U1-I OWNER'S GUIDE SAWAFUJI ELECTRIC CO., LTD. GENERAL: This appliance is designed to convert

More information

Series Temperature Controller Instruction Sheet

Series Temperature Controller Instruction Sheet Series Temperature Controller Instruction Sheet Thank you very much for purchasing DELTA A Series. Please read this instruction sheet before using your A series to ensure proper operation and please keep

More information

YCIV Hz & Hz

YCIV Hz & Hz YCIV 0590-1500 50Hz & 0157-0397 60Hz Start-up Checklist SERVICE POLICY & PROCEDURES Supersedes: Nothing Form 201.23-CL1 (309) Commissioning PREPARATION Commissioning of this unit should only be carried

More information

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation Standard C Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Standard C Standard C The Standard C thermostatic

More information

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY >OLYL >H]LSLUN[O 4H[[LYZ SMOKELESS FLARE MONITOR Smokeless Flare Monitor (FM) Smokeless flares incinerate flammable hazardous

More information

When ordering, please state type and code number. Max. Type - Capillary sensor of tube temp. charge length. C m

When ordering, please state type and code number. Max. Type - Capillary sensor of tube temp. charge length. C m Technical data and code nos. When ordering, please state type and code number. Thermostats with cylindrical remote sensor Adjustable differential range*) Types of charge A: Vapour charge - sensor must

More information

Installation Instructions for 116EXMLED Series AdaptaBeacon LED Lights for Use in Hazardous Locations. Description. Installation WARNING

Installation Instructions for 116EXMLED Series AdaptaBeacon LED Lights for Use in Hazardous Locations. Description. Installation WARNING Installation Instructions for 116EXMLED Series AdaptaBeacon LED Lights for Use in Hazardous Locations STANCHION 116EX-S CEILING 116EX-C 3/ CONDUIT ENTRIES PENDANT 116EX-P 3/ CONDUIT ENTRY 116EX-C (WALL

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Loop Alarm Model SC1290 and SCL1290 INSTALLATION INSTRUCTIONS LOVE LOVE CONTROLS a Division of Dwyer Instruments, Incorporated PO Box 338 Michigan City, IN 46361-0338 (800) 828-4588 (219) 879-8000 FAX

More information

Research Design Quality Value Service Experience

Research Design Quality Value Service Experience INDEX ACCUMULATORS...27 ACCUMULATOR - DRIERS...27 CAPILLARY ASSEMBLIES Strainer...30 Strainer-Drier...29 CHILLERS Heat Pump (For Capillary Systems)...22 Water (For Expansion Valves)...22 CONDENSERS (WATER

More information

Operating Instructions

Operating Instructions Important information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect

More information

Sinus Jevi (Explosion-Proof) Condens Heaters

Sinus Jevi (Explosion-Proof) Condens Heaters Sinus Jevi (Explosion-Proof) Condens Heaters Heating elements for dehumidification of sealed switchboards and control cabinets. Due to temperature limitations on e.g. print and plastic cabinets it is important

More information

SERVICE MANUAL FOR 6537 & 6538 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

SERVICE MANUAL FOR 6537 & 6538 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS SERVICE MANUAL FOR 6537 & 6538 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS TABLE OF CONTENTS 1. Warnings.................................................................. 2 2. Accessibility Of Appliance....................................................

More information

Hi-Pres Cooling Products Catalogue. Product Catalogue

Hi-Pres Cooling Products Catalogue. Product Catalogue Hi-Pres Cooling Products Catalogue Product Catalogue Important Notice This document is provided As is and is subject to change without prior notice. Novenco A/S reserves this right due to continuous product

More information

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately)

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately) Digital Panel Meter Low-cost, High-quality Digital Thermometer with Built-in Microcomputer Compact DIN-size (96 x 48 x 66 (W x H x D)) body. Mounting thickness of only 3.5 mm required. Highly visible display

More information

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

Flow switch.   Operating Manual. English manual page Page 1 of 15 Fax: Operating Manual www.jlso-tec-trade.de Flow switch English manual page 1-15 Page 1 of 15 Flow switch Table of Contents Page 1 Device Description and Intended Use... 19 1.1 Flow switch version VH...X...

More information

MS4PMUHVT Multi-Stage Electronic Temperature Control with Relay Pack

MS4PMUHVT Multi-Stage Electronic Temperature Control with Relay Pack Product/Technical MS4PMUHVT Issue Date 09/30/02 MS4PMUHVT Multi-Stage Electronic Control with Relay Pack The MS4PMUHVT Multi-Stage Electronic Control is intended for multi-stage temperature control applications.

More information

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers T4031A,B,P; T6031A,B Refrigeration Temperature Controllers FEATURES PRODUCT DATA Wide control temperature range is suitable for controlling ducts, tanks, freezers, coolers, display cases. and defrost termination.

More information

Tubular Industrial Process

Tubular Industrial Process Alternate NEMA 1 Housing Type 3N (for no thermostat) for 1", 1-1/4", 2" and 2-1/2" Screw Plug Heaters Screw Plug Immersion Heaters TYPE 4N (for no thermostat) for 1", 1-1/4", 2" and 2-1/2" Screw Plug Heaters

More information

ACZC GENERAL CHARACTERISTICS VERSIONS OPTIONS ON REQUEST STANDARD OPTIONS AIR COOLED CHILLER WITH SCROLL COMPRESSORS. Cooling capacity: 170 kw 675 kw

ACZC GENERAL CHARACTERISTICS VERSIONS OPTIONS ON REQUEST STANDARD OPTIONS AIR COOLED CHILLER WITH SCROLL COMPRESSORS. Cooling capacity: 170 kw 675 kw Z IR OOLED HILLER WITH SROLL OMPRESSORS ooing capacity: 70 7 GENERL HRTERISTIS VERSIONS IR OOLED HILLERS 0 Muti scro compressors Direct expansion pate to pate type evaporator; eectrica heater to prevent

More information

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL SAP K161GJA SAP K181GJA SAP K181MBA SAP K241GJA SAP K241MBA + SAP C161GA + SAP C161JA + SAP C181GA + SAP C181JA + SAP C181MA + SAP C181BA + SAP C241GA + SAP C241JA + SAP C241MA

More information

Two-Position Electric Duplex Room Thermostats

Two-Position Electric Duplex Room Thermostats TC-XX Series, TC-XX Series, TF- Series Two-Position Electric Duplex Room Thermostats These thermostats provide on-off control of heating/cooling systems. TC-XX Series, TC-XX Series, TF- Series Features:

More information

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS RV Products A Division of Airxcel, Inc. P.O. Box 4020 Wichita, KS 67204 1-316-832-4357

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CLM97 CLM7 CLM7 FILE NO. Destination: North America DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 9,700 BTU/h,00 BTU/h 0,600 BTU/h Outdoor Model No.

More information

INSTALLATION INSTRUCTIONS & REPLACEMENT PARTS LIST

INSTALLATION INSTRUCTIONS & REPLACEMENT PARTS LIST INSTALLATION INSTRUCTIONS & REPLACEMENT PARTS LIST MC4000 SERIES SOLID STATE DUAL UNIT LEAD/LAG CONTROLLER Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving ahead, just as planned.

More information

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Polytron 5700 IR Detection of flammable gases and vapours Dräger Polytron 5700 IR Detection of flammable gases and vapours The Dräger Polytron 5700 IR is a cost effective explosion-proof transmitter for the detection of flammable gases in the lower explosive