AREMA C&S Manual 2018 (Includes 2018 Revisions) Volume 4 Index. Part C Type & Subject Pages Status
|
|
- Collin Powers
- 5 years ago
- Views:
Transcription
1 SECTION 16 - VITAL CIRCUIT AND SOFTWARE DESIGN 16.1 Recommended Nomenclature Recommended Circuit Nomenclature 17 Revised Recommended Symbols Recommended Graphical Symbols for Wayside Signals 1 Reaffirmed Recommended Graphical Symbols for Signal Supports 1 Reaffirmed Recommended Graphical Symbols for Buildings, Bridges and Tunnels 1 Reaffirmed Recommended Graphical Symbols for Wayside Fixtures 1 Revised Recommended Graphical Symbols for Switches 2 Reaffirmed Recommended Graphical Symbols for Derails 1 Reaffirmed Recommended Graphical Symbols for Miscellaneous Devices Applied to Tracks 3 Revised Recommended Graphical Symbols for Relays 1 Reaffirmed Recommended Graphical Symbols for Relay Contacts 2 Reaffirmed Recommended Graphical Symbols for Circuit Controller Contacts, Miscellaneous 2 Reaffirmed Note: C = Committee responsible for Manual Part.
2 Index (Includes 2018 Revisions) Volume Recommended Graphical Symbols for Circuit Controller Contacts, Contacts Actuated Mechanically by Interlocking Machine Lever or Latch Contacts 1 Reaffirmed Recommended Graphical Symbols for Contacts Actuated by Switch Points, Derails or Locking Connections 2 Reaffirmed Recommended Graphical Symbols for Signals and Electro-Pneumatic Devices 1 Revised Recommended Graphical Symbols for Indicators, Locks, Buzzers and Bells 1 Reaffirmed Recommended Graphical Symbols for Circuit Appurtenances 3 Revised Recommended Graphical Symbols for Miscellaneous Apparatus 1 Revised Recommended General Design Guidelines Recommended Vital Circuit Relay Based Systems 5 Revised Recommended Application Design Guidelines for Isolation of Power Supplies Used in Vital Signal Systems 2 Revised Interlocking & Control Point Recommended Circuits Recommended Vital Circuit Time Locking 5 Revised Recommended Vital Circuit Route Locking 5 Reaffirmed
3 Recommended Vital Circuit Traffic Circuits at Interlocking and Control Points 4 Revised Recommended Vital Circuit Route Check Networks at Interlocking and Control Points 3 Revised Recommended Vital Circuit Design Guidelines for Home Networks at Interlockings and Controlled Points 4 Revised Recommended Guidelines for Battery Check Circuits 6 Revised Recommended Vital Circuit Lossof-Shunt Circuits 4 Reaffirmed Recommended Vital Design Guidelines for Trap Circuits 7 Extended Recommended Vital Circuit Stuck- Mechanism Detection for Controlled Signals 6 Reaffirmed Recommended Vital Circuit Following Move Stick Circuits at Interlocking and Control Points 3 Revised Recommended Vital Circuit Engine Return Stick Circuits at Interlocking and Control Points 3 Reaffirmed
4 Index (Includes 2018 Revisions) Volume Recommended Vital Circuit Light Out Detection on Color-Light Signals 7 Revised Recommended Vital Circuit Approach-Lighting Controlled Searchlight Signals. 3 Revised Recommended Vital Design Guidelines for Field Track Blocking at Interlockings and Controlled Points 3 Revised Recommended Automatic Speed Control with Continuous Cab Signaling 10 Extended Recommended Vital Circuit Design Guidelines for the Zoning of Processor- Based Control Points and Interlockings 27 New Recommended the Organization of Vital and Non-Vital Application Programs Using Nodal Logic Techniques 7 New Recommended Automatic Signal Circuits Recommended Vital Circuit Four Wire Tumbledown Line Circuits in Traffic Control Systems 4 Revised Recommended Vital Circuit and Software Limited Tumbledown Applications in Traffic Control Systems 4 Reaffirmed
5 Recommended Vital Design Guidelines for Directional Stick Circuits at Automatic Signals in TCS 2 Revised Recommended Vital Circuit Stuck- Mechanism Detection for Automatic Signals 3 Revised Recommended Vital Circuit Directional Stick Circuits at Automatic Signals 2 Revised Recommended Circuits for Switches A B 37-3 Recommended Vital Design Guidelines for Self-Restoring Switches in Traffic Control Systems 8 Revised Recommended Vital Circuit Self- Restoring Switches in Automatic Block Signal Territory 7 Reaffirmed C 37-3 Recommended Vital Design Guidelines for Self-Restoring Switches in Non-Signaled Territory on Main Tracks 8 Revised Recommended Vital Circuit Spring Switches 3 Reaffirmed Recommended Vital Circuit Design Guidelines Using Electric Switch Machines 7 Revised Recommended Vital Circuit Design Guidelines for Electric Lock Switch Control at Non-Interlocked Switches 5 Revised
6 Index (Includes 2018 Revisions) Volume Recommended Special Design Applications Recommended Vital Design Guidelines for Slide Fences 4 Reaffirmed Recommended Highway-Rail Grade Crossing Warning System Circuits Recommended Vital Circuit Stick Circuits with Grade Crossing Warning Systems 2 Reaffirmed Recommended Vital Circuit Reverse Switch Cut-Out Applications for Deactivating Grade Crossing Warning Devices 3 Reaffirmed Recommended Vital Circuit Pushbutton Cut-Out for Manually Terminating or Restarting Grade Crossing Warning Devices 2 Revised Recommended Vital Circuit Highway Traffic Signal or Other Traffic Control Device Interconnection 9 Revised Recommended Vital Circuit Interconnection of Grade Crossing Warning Systems on Adjacent Tracks 6 Reaffirmed Recommended Vital Circuit Timing Circuits 3 Revised
7 Recommended Vital Circuit Relay Based Flashing-Light Applications for Grade Crossing Warning Devices 3 Reaffirmed Recommended Vital Circuit Flashing-Light and Gate Control Applications for Grade Crossing Warning Devices 3 Reaffirmed Recommended Drawings Location Plan: C.P. Brannen 1 Reaffirmed Line Circuit in Traffic Control System 2 Reaffirmed Home Network Circuits 2 New
Railway Signal and Traffic Control Systems Standards
Railway Signal and Traffic Control Systems Standards June 4, 2007 TM Railway Signal and Traffic Control Systems Standards Effective: June 4, 2007 CONTENTS 1. SCOPE 2. DEFINITIONS 3. RAILWAY SIGNALING DESIGN
More informationALTERNATIVE PROPOSAL TO SATISFY REQUIREMENTS OF FRA RS&I -- RULE GROUNDS AUTHORS
ALTERNATIVE PROPOSAL TO SATISFY REQUIREMENTS OF FRA RS&I -- RULE 236.2 GROUNDS AUTHORS TIMOTHY C. HEYWOOD SENIOR DESIGN ENGINEER WAYSIDE PRODUCTS ALSTOM SIGNALING, INC. JAMES B. BALLIET VICE PRESIDENT
More informationType 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B
PRODUCT BULLETIN SB 8001B Type 8001 ALARM ANNUNCIATOR TYPE8001 FEATURES 16 or 32 alarm points per flush mount enclosure Displays are backlit with long life LEDs and engraved to suit Dimmer controls built
More informationUser Operation Manual
APPROVED BY: JBJ PRESCIENT III FIRE ALARM & GAS EXTINGUISHING CONTROL PANEL User Operation Manual PAGE 1 of 6 1 CONTENTS 1. FIRE - GENERAL... 3 2. FIRE - ZONES 1 OR 2 - AUTOMATIC MODE... 3 3. FIRE - ZONES
More informationIE Code IE Competency Title Credit OAC Ref.
Compulsory Workplace Competency Standards Level Four IE Code IE Competency Title Credit OAC Ref. IE119-4WC Design and draw electrical and electronic drawings including schematics, 4 F5 maintain documentation
More informationPWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R
Region Project Page 1 PART 1 - GENERAL 1.1 REFERENCES.1 CAN/ULC-S524-2006, Standard for the Installation of Fire Alarm Systems..2 CAN/ULC-S525-2007, Audible Signal Device for Fire Alarm Systems..3 CAN/ULC-S526-2007,
More informationControl Of Points. Withdrawn Document Uncontrolled When Printed. Railway Group Standard. Issue One Date July 1997
Date July 1997 Signatures removed from electronic version Submitted by... Richard Genner Nominated Responsible Manager Approved by... Philip Wiltshire Chairman, Train Control & Communications Subject Committee
More informationCONTRACT SPECIFICATION FOR THE DESIGN AND FURNISH OF THE BROAD STREET SUBWAY RIDGE AVE SPUR RECONSTRUCTION PROJECT. ADDENDUM No.3
CONTRACT SPECIFICATION FOR THE DESIGN AND FURNISH OF THE BROAD STREET SUBWAY RIDGE AVE SPUR RECONSTRUCTION PROJECT FAIRMOUNT TO 8 TH AND MARKET ADDENDUM No.3 Broad Street Subway TOC-1 Table of Contents
More informationFire and Gas Monitoring Panel ST7-HV
Fire and Gas Monitoring Panel ST7-HV INTRODUCTION TO THE ST7-HV SYSTEM The ST7-HV system is a programmable PLC suitable for safety and security installations with a high technological and economic content
More informationStatus Date Prepared Reviewed Endorsed Approved
Discipline Engineering Standard - NSW Category Signalling Title Reference Number SPS 08 - (RIC Standard: SC 01 51 00 00 SP) Document Control Status Date Prepared Reviewed Endorsed Approved May 05 Standards
More informationUser s Manual and Warranty Information ThyssenKrupp Access
User s Manual and Warranty Information ThyssenKrupp Access Welcome to your Destiny ThyssenKrupp Access would like to thank you for choosing the Destiny. You have purchased one of the finest residential
More informationModel VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass
Project: Customer: Engineer: Pump Manufacturer: Submittal Document Model VPS Pressure Limiting (VFD) with Soft Start Bypass Contents: Data Sheets Dimensional Data Wiring Schematics Field Connections Note:
More informationGRADE CROSSING SIGNAL SYSTEM SAFETY REGULATIONS
GRADE CROSSING SIGNAL SYSTEM SAFETY REGULATIONS Part 212 212.231 Highway-rail grade crossing inspector State inspectors would be authorized to enforce grade crossing system safety regulations. 212.233
More informationNot to be reproduced without the permission of Last date for receipt of BIS or used as a STANDARD comments is: 15 July 2012
For Comments Only Draft Indian Standard Graphic technology -- Safety systems -- Part 1: General requirements ICS 37.100.10 Not to be reproduced without the permission of Last date for receipt of BIS or
More informationApplication, Installation, Operation & Maintenance Manual
APPROVED BY:JBJ PRESCIENT III FIRE ALARM & GAS EXTINGUISHING CONTROL PANEL Application, Installation, Operation & Maintenance Manual PAGE 1 of 43 CONTENTS 1. INTRODUCTION... 3 2. GENERAL DESCRIPTION...
More informationNZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL
NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL Document No...G108WO1.DOC Serial No... Issue Date...17 th SEPTEMBER 1999 Software Version...1.4 APPROVED TO: NZS 4512:1997 AS/NZS 3548:1992 Fire Alarm
More informationElectronic Circuit Controller
Union Switch & Signal Inc., an Ansaldo Signal company 1000 Technology Drive, Pittsburgh, PA 15219 645 Russell Street, Batesburg, SC 29006 SM 9020, Field Test Unit (N42252601) for the Electronic Circuit
More informationBackground information
Infrastructure & Cities Sector Background information Mobility and Logistics Division Munich, October 10, 2013 Rail automation in mass transit systems How does automatic train control work? In automatically
More informationWashington Metropolitan Area Transit Authority. Red Signal Violations (RSV) June 20 and 27, July 12, 2012
Washington Metropolitan Area Transit Authority Red Signal Violations (RSV) Grosvenor Station Center Pocket Track June 20 and 27, 2012 Safety and Security Committee July 12, 2012 RSV Incident June 20, 2012
More information16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5
Construction Standards Page 1 of 5.1 General Description.1 The University requires that all new fire alarm system control panel, components, and devices, as required for the project, be Secutron 2900 Series
More informationBEHIND THE LINES. Guarding & Machine Safety. Ian Hansen RotoConsult ARM Annual Meeting ARM Annual Meeting
BEHIND THE LINES Guarding & Machine Safety Ian Hansen RotoConsult www.ianhansenconsult.com Summary of presentation Industry Association resources Machine Safe Guarding Risk Assessment vs Risk Reduction
More informationVIDEO VISITATION APPLICATION: FUNCTIONS AVAILABLE:
VIDEO VISITATION S E C U R I T Y E L E C T R O N I C S APPLICATION: SecurVu Video Visitation provides a robust IP-based solution custom designed for the harsh correctional environment. Facilities of any
More informationAnalog Room Pressure Monitor RPC Series
Description The Room Pressure Monitor is used to measure differential pressure in the range of 0.125 to 1"wc or 30 to 250 Pa. It combines precision high sensitivity silicon sensing capabilities and the
More informationLa Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual
La Marche Manufacturing Company www.lamarchemfg.com Option 16 Series Digital Combined Accessory Package Installation and Operation Manual This manual is subject to change without notice. You may obtain
More informationEDW500 / EDW503. Electronic Controls for Dishwashers
EDW500 / EDW503 Electronic Controls for Dishwashers ESSE-N / A.S. October 2004 EDW500 - EDW503 EDW500 and EDW503: new entry level electronic controls for dishwashers in the DIVA family Intended to replace
More informationModel VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch
Project: Customer: Engineer: Pump Manufacturer: Technical Data Submittal Document Model VPS + VPU Pressure Limiting (VFD) with Soft Start Bypass with Automatic Transfer Switch Contents: Data Sheets Dimensional
More informationNORMS AND REGULATIONS FOR AUTOMATIC DOORS & ENTRANCE CONTROLS
Chapter 5 NORMS AND REGULATIONS FOR AUTOMATIC DOORS & ENTRANCE CONTROLS When writing specifications, considerations should be given to the following: he Door should not form the only entrance/exit to an
More informationDeluge System. Pneumatic Release. Deluge System. Pneumatic Release
Deluge System Pneumatic Release Deluge System Pneumatic Release When the fixed temperature release () is activated by fire, pressure in the release system escapes from the open device, allowing the pneumatic
More informationProject: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch
Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU with Automatic Power Transfer Switch Contents: NOTE: The drawings included in this package are for controllers covered under our standard
More informationDrawing Submittal Package
Project: Customer: Engineer: Pump Manufacturer: Drawing Submittal Package Model GPL + GLU Limited Service Full Voltage Across the Line Start Electric Pump Controller with Automatic Power Transfer Switch
More informationPneumatic Heat Press. Revision: 3 Operators Manual
Pneumatic Heat Press Revision: 3 Operators Manual Wader Labelling Systems Ltd 2003 Location and Set-up. The press must be located near to a filtered air supply and a 240v singlephase mains supply. Ensure
More informationFor Signals Training onsortium Use Only
onsortium Use Only Inspection and Maintenance of Switches and Derails Course 202 PARTICIPANT GUIDE Inspection and Maintenance of Switches and Derails Participant Guide Signals Maintenance Training Consortium
More informationBLIND SPOT MONITORING (BSM) SYSTEM [Except Australian specs.]
SYSTEM [Except Australian specs.] id1510000028a2 Outline The blind spot monitoring (BSM) system detects vehicles approaching from behind using radar and alerts the driver of the presence of an approaching
More informationPERATOR. HYDRA Operator's Manual Volume 1 issue 4 revision TEC-TCC/ /OB page 1 of 23. document title/ titre du document
page 1 of 23 document title/ titre du document ANUAL PERATOR OLUME S prepared by/préparé par Otto Brunner reference/réference issue/édition 4 revision/révision 5 date of issue/date d édition 13-10-2008
More informationCotton Belt Corridor PE/EIS
Design Criteria Volume 2 02/28/2011 i Cotton Belt Corridor PE/IS Design Criteria Volume 2 2/28/11 Prepared by Stantec Consulting, Inc TABLE OF CONTENTS SECTION 1 - GENERAL... 1 1.1 GENERAL... 1 1.2 COMMUTER
More informationAXS Strikemaster Engineering Manual
AXS Strikemaster AXS Strikemaster Programming and Operation Manual Jan 2014 Page 1 of 23 Table of Contents Important Note... 3 Features and Benefits... 3 Ordering Details... 4 Dimensions... 5 Installation...
More informationTemperature-Relay TR210
Operating instructions Temperature-Relay TR210 Page 1 of 24 Table of contents 1. Application and Short description... 3 2. Overview of functions... 3 3. Connection Plan... 3 4. Display and operation parts...
More informationSYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System
SYSTEM MANUAL FT1-SB Single Zone Fire Alarm System DOCUMENT HISTORY Issue Date Description Written By Checked By Draft 0 2/9/2008 Original Document. A. Shenouda C. Orr Issue 1 4/11/2011 Update drawing
More informationGS100M Gas Detection Controller
GS100M Gas Detection Controller GS100M 1 Zone Gas Detection Controller 1 Zone / Sensor Conventional Positive Safety IP44 EN61010-1 EN50270 FEATURES Single Zone Protection Positive Safety Option Detection
More informationFire and Smoke Control Systems
Control Systems Electrical Mechanical Standard Panel Modular design for control and monitoring Premier Panel Customised design for control and monitoring Fully Addressable Fully programmable data wired
More informationARCHIVE GUARDING OF PAPER BALING PRESSES
GUARDING OF PAPER BALING PRESSES NOTE The technical information in this book was current at the time of printing in 1984. While the guarding principles are still valid, the information does not necessarily
More informationGeneral Specifications for Lighted Crosswalk Warning Equipment and Miscellaneous Materials, Rev 4
General Specifications for Lighted Crosswalk Warning Equipment and Miscellaneous Materials, Rev 4 Lighted Crosswalk Warning Equipment and Miscellaneous Materials 1) Quality of Materials and Equipment 2)
More informationLa Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual
La Marche Manufacturing Company www.lamarchemfg.com Option 46 Series Digital Combined Accessory Package Installation and Operation Manual This manual is subject to change without notice. You may obtain
More informationnugate Product Catalog
Product Catalog Pneumatic activegate Control Stabilize your Process CAT-16-0019_EN-Rev03 EN 06/2017 Pneumatic Valve Gate Product Description nugate Hot Runner System Proportionally controlled Pneumatically
More informationSafety Control Modules for Emergency Stop Circuits FF-SRS5988 FF-SRS5935 FF-SRS5925 FF-SRS5934 FF-SRS5924 TYPICAL APPLICATIONS APPROVALS DIMENSIONS
Safety Control Modules for Emergency Stop Circuits TYPICAL APPLICATIONS APPROVALS DIMENSIONS Single Channel Emergency Stop Module E-Stop circuits up to Category 2 (EN 954-) Sliding door protection Conveyors
More informationInfrastructure Projects Signalling - Shared Learning. 18/02: March 2018 December Dec-18 / 1
Infrastructure Projects Signalling - Shared Learning 18/02: March 2018 December 2018 20-Dec-18 / 1 Introduction This Shared Learning document details key issues and incidents that have occurred on Signalling
More informationISO INTERNATIONAL STANDARD. Safety requirements for industrial laundry machinery Part 1: Common requirements
INTERNATIONAL STANDARD ISO 10472-1 First edition 1997-12-15 Safety requirements for industrial laundry machinery Part 1: Common requirements Exigences de sécurité pour les machines de blanchisserie industrielle
More informationDryer Controller M720
User Manual Dryer Controller M720 Hardware version 2.00 Software version 2.00 Manual M720 Dryer controller Page 1 of 60 Document history Preliminary version: - Created in April, 2009 Hardware Version 2.00,
More informationInstaller: (Name, address, telephone number)
Installer: (Name, address, telephone number) UNAC GUIDE No. 9 FOR THE INSTALLATION OF MOTORISED VERTICAL UPWARD SLIDING GATES IN ACCORDANCE WITH MACHINERY DIRECTIVE 98/37/EEC AND THE APPLICABLE PARTS OF
More informationMBZ300. Emergency power control unit. GB Installation instructions MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 PME PME. Reset.
24V 24V PME PME CM DM SM DM WM Reset Reset Emergency power control unit GB Installation instructions 1 Table of contents 1 Symbols and illustrations...3 2 Product liability...3 3 Safety instructions...3
More informationRoth Touchline. German quality since Quick and easy user manual 1/10
Roth Touchline Quick and easy user manual German quality since 197 1/10 230 V Pump N N L L 230 V 230 V 2 V 2 V c/o in %H c/o out c/o in Trafo out /TB in N L eco 2V CH 1 CH 2 CH 3 CH 2V 2V 2V 2V 2V Touchline,
More information1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER
Application The unit is primarily intended for use where there is a requirement to integrate a limited fire protection function into a larger control equipment scheme, or in specialist applications where
More informationRidley Terminals Canada. Site HMI Station. In Central Office. Prepared by: Wayne Leung Controls Specialist. QCA Systems Limited
QCA Systems Limited Operation Manual Ridley Terminals Canada In Central Office Prepared by: Wayne Leung Controls Specialist QCA Systems Limited Version: 0 Date: February 28, 2013 TABLE OF CONTENTS 1.0
More informationSECTION LOW VOLTAGE LIGHTING CONTROLS
SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS PART 1 - GENERAL 1.01 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section
More informationACCESS SECURITY SYSTEMS (ELECTRONIC LOCKING) & ACCESSIBLE DOOR OPENING DEVICES ON MEANS OF ESCAPE
Fire Safety Technical Guide ACCESS SECURITY SYSTEMS (ELECTRONIC LOCKING) & ACCESSIBLE DOOR OPENING DEVICES ON MEANS OF ESCAPE Access Security & Accessible Door Opening Systems - what you need to know:
More informationPump Logic User Manual CB-1000 P/N ILK-CB1000-1
Pump Logic User Manual CB-1000 P/N ILK-CB1000-1 STATEMENT OF LIMITED WARRANTY The limited warranty applicable to this product is set forth in USFilter Control Systems standard terms of sale that are made
More informationACCESS SECURITY SYSTEMS (ELECTRONIC LOCKING) & ACCESSIBLE DOOR OPENING DEVICES ON MEANS OF ESCAPE
Fire Safety Technical Note ACCESS SECURITY SYSTEMS (ELECTRONIC LOCKING) & ACCESSIBLE DOOR OPENING DEVICES ON MEANS OF ESCAPE Access Security & Accessible Door Opening Systems - what you need to know: Access
More informationABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE
ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE isocket Smart Relay is a complex Smart House system which is installed in the fuse cabinet (electric cabinet) in the house. We therefore assume that
More informationIntelligent Security & Fire Ltd
OPERATIONAL NOTES FOR CONCEPT FIRE PANEL. NOTE ON NEW FIRE PANELS, POSITION 1 ON THE SIX WAY INTERNAL OPTION SWITCH IS TURNED ON, DISABLING THE ZONAL SOUNDERS. TO ENABLE ZONAL SOUNDERS TURN OFF. Operation
More informationELSEMA MD2010. Application Controls automatic doors or gates when a vehicle is present. Description
Loop Detector is used to detect metal objects such as motor vehicles, motor bikes or trucks. ELSEMA Features Wide supply range: 12.0 to 24 Volts DC 16.0 to 24 Volts AC Selectable sensitivity Pulse or Presence
More informationInstallation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels
CF5000, MF5000 and FXP5000 Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels 16 zone panels Contents PANEL INSTALLATION...3 Installation...3 PANEL WIRING... 3 Mains power
More informationGas Controller Module GC-06
Page 1 Oct. 2015/2 Measuring, warning and controlling module for toxic, combustible and refrigerant gases and vapours. The gas controller series GC-06 is designed in accordance with the standard EN 50545-1.
More informationLQQA Humidifier, for circulated water
Size -84 5 Fig. 4 5 4 6 8 7 9 7 8. Control box, on the outside. Control box, on the inside. Shut-off valve (not included) 4. Water filter, max. 5 mm mesh (not included) 5. LQAZ-8 Water trap (accessory)
More informationTelecab17 Residential Elevator OWNER S MANUAL
Telecab17 Residential Elevator OWNER S MANUAL (To Be Retained by Owner After Installation by Authorized Savaria Dealer) Part No. 001081 30-m06-2017 2 IMPORTANT Ensure that only an authorized Savaria Dealer
More informationFAQs - Codes and Listings
The ADA EZ Wire Free Door Opener fully complies with the Uniform Federal Accessibility Standards (UFAS) Section 4.4 on Protruding Objects. For convenience and clarity the section of the standard appears
More informationSEAR II APPLICATION 9V899-A01D PREPARED FOR NICTD
CONFIGURATION SUMMARY SEAR II APPLICATION 9V899-A01D PREPARED FOR NICTD APRIL 2008, REVISED MAY 2014 DOCUMENT NO. SIG-00-06-03-001 VERSION D.1 Siemens Industry, Inc., Rail Automation 9568 Archibald Ave.,
More informationELEVATOR UPGRADE AND MODERNIZATION
BOYLE COUNTY COURTHOUSE ELEVATOR UPGRADE AND MODERNIZATION SPECIFICATIONS 1-1-2017 1 ON Provide labor and material to furnish and install the following: SECTION I. SYSTEM OPERATING FEATURES DUTY The present
More informationInstruction Manual December 2001 ENACOCU02
SENACOCU02 Instruction Manual December 2001 ENACOCU02 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected
More informationDrawing Submittal Package
Project: Customer: Engineer: Pump Manufacturer: Drawing Submittal Package Model GPL + GLU Limited Service Full Voltage Across the Line Start Electric Pump Controller with Automatic Power Transfer Switch
More informationPakenham Branch Library Section MacFarlane Street MULTIPLEX FIRE ALARM SYSTEM Project No Page 1 of 12
Project No. 16563.001 Page 1 of 12 1. General 1.1. WORK INCLUDED 1.1.1. Section 26 05 01 GENERAL INSTRUCTIONS FOR ELECTRICAL SECTIONS. 1.1.2. Section 26 05 04 SUBMITTALS/SHOP DRAWINGS. 1.1.3. Section 26
More informationSAQCC FIRE D&GS TRAINING SUB COMMITTEE COURSE CURRICULUM. Standards Training SANS 369 ORIGINATOR
SAQCC FIRE D&GS TRAINING SUB COMMITTEE COURSE CURRICULUM COURSE Standards Training SANS 369 ORIGINATOR Keith Norgate DATE 24th July 2014 Amendment 1 17th September 2014 Add power battery calculations Amendment
More informationREPAIR INSTRUCTIONS. TUMBLE DRYER Vented WTA34.. / WTA35..
REPAIR INSTRUCTIONS TUMLE DRYER Vented WTA34.. / WTA35.. I. SAFETY INFORMATION Page 1 II. OPERATION Page 1 III. DESCRIPTION OF FUNCTION / TECHNICAL INFORMATION Page 2 IV. CONSUMPTION RATES / ENERGY REQUIREMENT
More informationThe Best In Machine Guarding Interlock Options
The Best In Machine Guarding Interlock Options Option 1: THESSQ1 locked the machine will operate. Operator can gain entry by pressing down the silver access handle and retracting the tongue from the safety
More informationInstaller: (Name, address, telephone)
Installer: (Name, address, telephone) UNAC GUIDE No. 5 FOR THE MOTORISATION OF FOLDING DOORS IN ACCORDANCE WITH MACHINERY DIRECTIVE 98/37/EEC AND THE APPLICABLE PARTS OF STANDARDS EN 13241-1, EN 12453,
More informationInstaller: (Name, address, telephone number)
Installer: (Name, address, telephone number) UNAC GUIDE No. 8 FOR THE INSTALLATION OF MOTORISED BARRIERS IN ACCORDANCE WITH MACHINERY DIRECTIVE 98/37/EEC AND THE APPLICABLE PARTS OF STANDARDS EN 13241-1,
More informationCU-02 with Senaco Plus
CU-02 with Senaco Plus Instruction Manual PL-509 July 2001 U-02 SENACO 33455090 Rev. 1.1 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect
More informationWHITE PAPER. Standard Product Safety Sign Catalog for Automotive Fire Apparatus RATIONALE
WHITE PAPER TC010 Issued December 3, 2012 Revised October 3, 2014 Standard Product Safety Sign Catalog for Automotive Fire Apparatus RATIONALE This document gives the fire apparatus manufacturers an option
More informationOperating manual. Condor Modular pump control CPSM
Condor Status: 27.01.2011 Version: 900 160 - V1.2 GLP: HW 1.30 SW: V2.21 This documentation refers exclusively to the control unit and contains basic information that must be adhered to during installation,
More informationInstaller: (Name, address, telephone)
Installer: (Name, address, telephone) UNAC GUIDE No. 2 FOR THE MOTORISATION OF HINGED GATES IN ACCORDANCE WITH MACHINERY DIRECTIVE 98/37/EEC AND THE APPLICABLE PARTS OF STANDARDS EN 13241-1, EN 12453,
More informationDENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL
PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. Minimum lighting control (base scope of work) shall include all corridors. The lighting in all the corridors shall be turned on (if not already on) if
More informationAmerex Fire Suppression Systems. Because Operators and the Environment are NOT Disposable Quality is Behind the Diamond.
Amerex Fire Suppression Systems Because Operators and the Environment are NOT Disposable Quality is Behind the Diamond. Quality is Behind the Diamond. Diamonds have long been a symbol for quality. At Amerex
More informationOriginal operating instructions Safety switch with guard locking AC901S AC902S
Original operating instructions Safety switch with guard locking AC901S AC902S 7390914/03 01/2017 Contents 1 Preliminary note...4 1.1 Explanation of symbols...4 2 Safety instructions...4 3 Items supplied...5
More informationTD80 LEVEL GAUGING & OVERFILL PREVENTION SYSTEM PRODUCT MANUAL SUPPLEMENT. TPM 005 Revision 0.0
TD80 LEVEL GAUGING & OVERFILL PREVENTION SYSTEM PRODUCT MANUAL SUPPLEMENT TPM 005 Revision 0.0 Table of Contents 1 TD80 Current Loop Option... 2 1.1 Introduction... 2 1.2 Components... 2 1.3 Operation...
More informationBasics of Safety Applications
Basics of Safety Applications Unrestricted Siemens 2016 usa.siemens.com/controls Why Safety Technology? Protection of People Environment Page 2 Safety Process Chain The necessary steps towards a safe machine
More informationControl Panel Engineering and Commissioning Instructions
Twinflex - V3 Fire Detection & Alarm System Control Panel Engineering and Commissioning Instructions (TO BE RETAINED BY THE COMMISSIONING ENGINEER) 26-0338 Issue 9 Fike s policy is one of continual improvement
More informationrecord.group User manual record FlipFlow Triple automatic door systems this is record! record your global partner for entrance solutions
record your global partner for entrance solutions User manual record FlipFlow Triple your global partner for entrance solutions record.group automatic door systems this is record! Table of contents Table
More informationBattery Fail Monitoring System
Battery Fail Monitoring System Table of Contents 1 DOCUMENTATION 1.1 Introduction 2 GENERAL INFORMATION 2.1 Scope of the Manual 2.2 Product Description 3 DESCRIPTION OF FEATURES, ALARMS AND CONTROLS 3.1
More informationINSTALLATION AND OPERATING MANUAL OF THE BASIC CONTROL PANEL (CCB) FOR THE FISAIR EVAPORATIVE HUMIDIFIERS
0 0 I INSTALLATI AND OPERATING MANUAL OF THE BASIC CTROL PANEL (CCB) FOR THE FISAIR EVAPORATIVE HUMIDIFIERS Software Version 8.0 MCCB-EN-17-1 In fulfilment of the Regulations of the European Union on Machine
More informationBasics of Safety Applications
Basics of Safety Applications Unrestricted Siemens 2016 usa.siemens.com/controls DISCLAIMER/ TERMS OF USE: THE INFORMATION PROVIDED HEREIN IS PROVIDED AS A GENERAL REFERENCE REGARDING THE USE OF THE APPLICABLE
More informationInstallation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels
Installation and user manual for the FX range of fire panels 1, 2, 4 and 8 zone panels Contents Panel installation 3 Panel connections 3 Wiring connection drawings 4 Panel facilities 6 Installation check
More informationSPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL
SECTION 1 - GENERAL CONDITIONS I. SCOPE: This specification outlines the requirements for a Fike Micromist Water Mist Fire Suppression System with automatic detection and control. The work described in
More informationInteractive Fire Control Panel IFS7002 four signal loops Instruction Manual
Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual Revision 6/01.17 Contents 1. Introduction... 6 2. Terminology... 6 3. Function... 8 4. Technical data... 8 4.1. Physical configuration...
More informationKwêBeams Effective wire free outdoor early warning system
1 KwêBeams Effective wire free outdoor early warning system Features: - Easy to install & use - Operates on 868Mhz frequency (less congested to avoid signal jamming) - All sensors with built in sirens,
More informationInstaller: (Name, address, telephone)
Installer: (Name, address, telephone) UNAC GUIDE No. 4 FOR THE MOTORISATION OF SECTIONAL GARAGE DOORS IN ACCORDANCE WITH MACHINERY DIRECTIVE 98/37/EEC AND THE APPLICABLE PARTS OF STANDARDS EN 13241-1,
More information1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point
Medium - Control - System Franke & Haqenest GmbH Borngasse 1a * 04600 Altenburg Tel: 03447-499 313-0 Fax: 03447-499 313-6 email: info@mcs-gaswarnanlagen.de MCS User Guide MCS GasController Microprocessor
More information5900 SERIES Low Energy Power Operator
Low Energy Power Operator introduction The Norton 5900 Series is a full-featured, extremely quiet, low energy door operator designed for moderate to high traffic doors. This cost-effective operator is
More informationAFP-300/400 OPERATORS MANUAL INTELLIGENT FIRE DETECTION AND ALARM SYSTEM SOFTWARE VERSION 2.2 REVISION AUS 3
OPERATORS MANUAL AFP-300/400 INTELLIGENT FIRE DETECTION AND ALARM SYSTEM SOFTWARE VERSION 2.2 REVISION AUS 3 NSW (Head Office) 7 Columbia Court Norwest Business Park Baulkham Hills NSW 2153 Ph: (02) 9899-4155
More informationPlanning Instructions MEW01472 Revision -
Planning Instructions MEW01472 Revision - Fire Alarm System EBL512 G3 United version 2.7.x Author: Jan Pettersson Date of issue: 2012-04-05 Date of rev: This page has deliberately been left blank. Table
More informationIEC61511 Standard Overview
IEC61511 Standard Overview Andre Kneisel Instrumentation Engineer Chevron C.T. Refinery SAFA Symposium 2011 August 5 th, 2011 Presentation Overview Provide some understanding of the key aspects of Functional
More informationOperating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content
8 Appendix 8.1 Wiring examples...4 8.2 Start configuration...4 8.3 Sensor configuration...4 8.4 Actuator configuration...5 Operating instructions.............pages 1 to 6 Original 9 EU Declaration of conformity
More information