TACOTHERM FRESH PETA (C/CL)

Size: px
Start display at page:

Download "TACOTHERM FRESH PETA (C/CL)"

Transcription

1 ACOHERM FRESH PEA (C/CL) FRESH HO WAER SAION WIH HIGH-EFFICIENCY PUMPS Fresh hot water station for hygienically heating drinking water in accordance with the continuous flow principle with and without dual-zone return stratification of the storage tank. ADVANAGES Compact and versatile Models: with and without circulation pump, dual-zone return stratification Cascading possible Secure Integration in building control system via optionally available ModBus RU interface Integrated safety subassembly and soft-close valves Simple Valves and components are fully preassembled as well as fully wired ready for connection Efficient High transmission performance and low pressure loss thanks to microplate plate heat exchanger DESCRIPION he acoherm Fresh Peta (C/CL) fresh water station is used for on-demand preparation of domestic hot water in accordance with the continuous flow principle. It retrieves the heat from the storage tank of an existing or new heating system, which uses solid-fuel boilers, heat pumps, solar systems, etc. as a heat source. he station replaces the storage of hot drinking water and thus provides a high degree of protection against Legionella by avoiding water stagnation. INSALLAION POSIION Vertical wall-mounting in the vicinity of the hot water storage tank or on the tank itself. OPERAION Drinking water is heated to the defined dispensing temperature in the acoherm Fresh Peta (C/CL) in accordance with the continuous flow principle. he integrated heat exchanger is supplied with as little hot water from the storage tank as is required to maintain a constant dispensing temperature. A low return temperature of the heating water to the storage tank can be expected owing to the special design of the heat exchanger. In recording the temperature difference and flow rate data, the electronic regulator simultaneously records and stores the quantity of heat consumed. In addition to an additional circulation pump that can be installed, the acoherm Fresh Peta (C/CL) can also be supplied with a switching valve for dual-zone return stratification. he primary pump, circulation pump as well as load valve are controlled by the integrated regulator in accordance with specifications. SYSEM/BASIC DIAGRAM BUILDING CAEGORIES Apartment blocks Housing estates Multiple dwelling units Residential care facilities and hospitals Administration and service buildings Hotels and restaurants, industrial kitchens School buildings and sports facilities Commercial and industrial buildings, industrial facilities Facilities with partial use for example barracks, camping sites, etc.

2 ACOHERM FRESH PEA (C/CL) FRESH HO WAER SAION SPECIFICAION EX See ECHNICAL DAA General acoherm Fresh Peta controller with display Weight (empty):. kg Overall dimensions (incl. hood): W mm H mm D 1 mm Material Base plate: Galvanized sheet steel Hood: Varnished sheet steel Pumps: Primary: Cast iron Secondary: PPS (plastic, approved for drinking water) Valve housing: Brass Pipes: Primary/secondary DN, stainless steel 1. Circulation DN, stainless steel 1. Microplate plate heat exchanger: Plates and connector pieces: Stainless steel 1.1 Heat exchanger solder:. % copper (on request: stainless steel solder) Seals: AFM flush seal Primary side Operating temperature O max : C Operating pressure P O max : bar Primary pump: Grundfos UPML - Secondary side Operating temperature O max : C Operating pressure P O max : bar Safety valve (intrinsic safety): bar discharge pressure and bar closing pressure Circulation pump: Grundfos UPM Auto L 1- CIL Electrical connection data Mains voltage: VAC ± % Mains frequency:... Hz Power consumption: max. W. A fuse ebus interface Protection type: IP Flow media Heating water (VDI ; SWKI B -1; ÖNORM H 1 1) Cold water YPE OVERVIEW acoherm Fresh Peta, Peta C and Peta CL Fresh hot water station Order no. Rp Version Version.. 1 ¼" I Without circulating pump, without dual-zone return stratification.. 1" I / With circulating pump, C 1 ¼" I without dual-zone return stratification.. DIMENSIONAL DRAWING E DN DN A 1 DN D 1 PW PRODUC DIAGRAM 1" I / 1 ¼" I D IG 1-1/" IG 1-1/" B 1C DN DN CL With circulating pump and dual-zone return stratification APPROVALS / CERIFICAES Components in contact with potable water comply with UBA Evaluation Criteria //1 and Directive (EU) 1/1 1 Primary hot water flow Primary hot water return 1 (integration of storage tank below) Primary hot water return (integration of storage tank in center in CL models) Circulation (C/CL version) (1") Cold water connection Hot water connection Primary pump Circulation pump (C/CL version) Flow rate sensor Safety valve Heat exchanger Regulator 1 Switching valve (CL version)

3 ACOHERM FRESH PEA (C/CL) FRESH HO WAER SAION FLOW AND PRESSURE LOSS DIAGRAMS COLD WAER HEAING A K (... C) D) Secondary pressure loss C) Return temperatures C 1 1 Secondary pressure loss Secondary pressure loss in circulation Pump curve, DHW circulation stage 1 Pump curve, DHW circulation stage Pump curve, DHW circulation stage Pump curve, DHW circulation stage Pump curve, DHW circulation stage Pump curve, DHW circulation stage Pump curve, DHW circulation stage * If a higher primary flow temperature (> C) is anticipated (e.g. with solar thermal/wood combustion systems), it is recommended that a thermostatic mixing valve (NovaMix Value) be installed in the primary flow of the domestic hot water station. Return temperature ( C) C C 1 A) Cold water heating at K B) Residual head Primary pressure loss C C C* ( p) Output kw 1 kw 1 EXAMPLE FOR INERPREING HE FLOW RAE AND PRESSURE LOSS DIAGRAMS Given Hot water dispensing volume: l/min Primary heating flow temperature: C Sought Primary heating return temperature in C Secondary pressure loss in mbar Primary pressure loss in mbar Approach In Diagram A) the hot water demand at the intersection point of the dispensing volume of l/min and primary flow temperature of C is l/h. In Diagram B) the primary pressure loss for a hot water demand of l/h is mbar. he pump delivery head is mbar, discounting the pressure loss this gives rise to a residual pump head of mbar (Δp). In Diagram C) the primary return temperature for a given dispensing volume of l/min and the selected flow temperature of C is 1. C. In Diagram D) the secondary pressure loss for the given data is mbar

4 ACOHERM FRESH PEA (C/CL) FRESH HO WAER SAION FLOW AND PRESSURE LOSS DIAGRAMS COLD WAER HEAING A K (... C) acoherm Fresh Peta CL D) Secondary pressure loss Druckverlust Sekundär C C C kw erlust mbar Druckve Druckverlus t sek. Druckverlus t Zirkula on Zirkula onp umpe UPM Pump curve, DHW circulation stage * If a higher primary flow temperature (> C) is anticipated (e.g. with solar thermal/wood combustion systems), it is recommended that a thermostatic mixing valve (NovaMix Value) be installed Zapfmenge l/min C) Return temperatures Rücklau emperaturenin the primary flow of the domestic hot water station. R C C C 1 1 C 1 C 1 C 1 1 C 1 1 C C 1 1 C C 1 C C C Zapfmenge l/min Kaltwassererwärmung um K (- C) Res örderhöhe A) Cold water heating at K B) Residual head Primary pressure loss C Return temperature ( C) 1 ter/h peratur C Rücklau emp C C C C C C C C* C 1 Secondary pressure loss Secondary pressure loss in circulation Pump curve, DHW circulation stage 1 Pump curve, DHW circulation stage Pump curve, DHW circulation stage Pump curve, DHW circulation stage Pump curve, DHW circulation stage Pump curve, DHW circulation stage kw Heizwasserbedarf Li C Leistung KW k Heizwasserbedarf Liter/h 1 mbar l/min 1 Pressure loss (l/min) Grundfos UPML - l/h. p NOE REQUIREMENS FOR FLOW MEDIA he stations heat interface units use a copper-soldered stainless steel plate heat exchanger as standard. It must be checked prior to use in the framework of system planning whether the issues of corrosion protection and scale formation have been sufficiently taken into account in accordance with DIN 1 and current drinking water analyses according to DIN EN. See datasheet Plate Heat Exchanger Requirements - Limit Values for Drinking Water Quality.

5 ACOHERM FRESH PEA (C/CL) FRESH HO WAER SAION ACCESSORIES CASCADE CIRCUIRY Order no. Rp Description.. Basic construction kit.1. Extension kit.. Second zone valve for basic construction kit (sequence switching operation).. 1 ¼" External storage restratification.. " External storage restratification..1 External circulation.. ModBus RU interface.. RC interface SAMPLE ORDER CASCADE MODULE WIH SEQUENCE CHANGEOVER Cascade circuit with integrated circulation and storage stratification Order no. -way cascade -way cascade -way cascade -way cascade * 1*.1. 1 * * Cascade circuit with external circulation and external storage stratification Order no. -way cascade -way cascade -way cascade -way cascade * 1*.1. 1 * * * * Attention: Note pressure losses in the cascade pipe sets and diverting valves. Subject to modification. /1 CONAC AND FURHER INFORMAION ACONOVA.COM aconova Group AG Neunbrunnenstrasse CH- Zurich +1 F +1 group@taconova.com

TACOTHERM FRESH PETA X (C/CL)

TACOTHERM FRESH PETA X (C/CL) ACOHERM FRESH PEA X (C/CL) FRESH HO WAER SAION WIH HIGH-EFFICIENCY PUMPS Fresh hot water station for hygienically heating drinking water in accordance with the continuous flow principle with and without

More information

Preconfigured heat interface unit with compact installation depth for preparation of domestic hot water and apartment heating.

Preconfigured heat interface unit with compact installation depth for preparation of domestic hot water and apartment heating. T T TACOTHERM DUAL PIKO HEAT INTERFACE UNIT ADVANTAGES Compact installation depth Large number of variants Preconfigured for simple installation On-demand, hygienic preparation of domestic hot water Demand-driven

More information

HEAT INTERFACE UNITS (Sanitary Hot Water Only)

HEAT INTERFACE UNITS (Sanitary Hot Water Only) HEAT INTERFACE UNITS (Sanitary Hot Water Only) T-FAST i20 (Sanitary Hot Water Only) 20 The T-Fast i20 is an instantaneous domestic hot water production module that produces a flow rate of 20L per/min at

More information

TACOTHERM DUAL DECENTRALISED DOMESTIC HOT WATER TECHNOLOGY

TACOTHERM DUAL DECENTRALISED DOMESTIC HOT WATER TECHNOLOGY TACOTHERM DUAL DECENTRALISED DOMESTIC HOT WATER TECHNOLOGY WHAT DOES TACONOVA STAND FOR? Taconova Group AG is a well-established Swiss company with over years of experience in providing intelligent building

More information

TACOTHERM DUAL PIKO MODULAR AND HIGHLY FLEXIBLE HEAT INTERFACE UNITS

TACOTHERM DUAL PIKO MODULAR AND HIGHLY FLEXIBLE HEAT INTERFACE UNITS TACOTHERM DUAL PIKO MODULAR AND HIGHLY FLEXIBLE HEAT INTERFACE UNITS CUSTOMIZE YOUR INDIVIDUAL STATION The heat interface units in the TacoTherm Dual Piko range adapt perfectly to local conditions. Whether

More information

ThermoDual Domestic hot water charging system

ThermoDual Domestic hot water charging system ThermoDual Domestic hot water charging system Description/Application ThermoDual is the compact and effective domestic hot water (DHW) charging system. Due to the consistent use of carefully selected components

More information

New TERMOVAR Loading Unit. The link between bio-energy boiler and storage tank system

New TERMOVAR Loading Unit. The link between bio-energy boiler and storage tank system New TERMOVAR Loading Unit The link between bio-energy boiler and storage tank system New TERMOVAR Loading Unit The link between bio-energy boiler and storage tank system TERMOVAR LOADING UNIT is a pre-fabricated,

More information

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT DOC1066 GB STOKVIS ENERGY SYSTEMS 96R WALTON ROAD EAST MOLESEY SURREY KT8 0DL TEL: 08707 707 747 FAX: 08707 707 767 E-MAIL:info@stokvisboilers.com

More information

Smart temperature control solutions

Smart temperature control solutions Smart temperature control solutions State-of-the-art heating and cooling solutions, expertise & know-how combined with top quality and superior customer service. 1 1 8 7 5 9 6 10 4 3 2 www.vexve.com Contents

More information

Stokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing

Stokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing Stokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing Water Heater Supplement STOKVIS ENERGY SYSTEMS 96R Walton Road East Molesey Surrey KT8 0DL Tel: 020 8783 3050 / 0870 7707747 Fax: 020

More information

Build on Uponor with Aqua Port Central. Central fresh domestic hot water stations for private homes, hotels and healthcare

Build on Uponor with Aqua Port Central. Central fresh domestic hot water stations for private homes, hotels and healthcare Build on Uponor with Aqua Port Central Central fresh domestic hot water stations for private homes, hotels and healthcare Uponor Aqua Port Central Central fresh domestic hot water stations The hygienic

More information

KEMPER ThermoSystem. For further information on KTS use the QR code!

KEMPER ThermoSystem. For further information on KTS use the QR code! KEMPER ThermoSystem Heating water hygienically and energy-efficiently with patented cascade rotation for automated operating change among all heating modules For further information on KTS use the QR code!

More information

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services TA-COMFORT-S Prefabricated units Heating interface unit for surface heating and hot water services IMI TA / Control valves / TA-COMFORT-S TA-COMFORT-S All in one design with STAP differential pressure

More information

Thermowatt Sistemas Técnicos. Piso radiante.

Thermowatt Sistemas Técnicos. Piso radiante. Thermowatt Sistemas Técnicos Piso radiante www.thermowatt.pt UNDERFLOOR HEATING SYSTEMS The targeted heating of individual rooms increases the comfort level, reduces energy consumption and allows economical

More information

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Reduced Installation time Precision regulation Minimal tooling required 100% tested prior to packaging High quality

More information

Installation and Operation Instructions Domestic hot water module FriwaMini with circulation - DN 15

Installation and Operation Instructions Domestic hot water module FriwaMini with circulation - DN 15 PAW GmbH & Co.KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 E-mail: info@paw.eu, Web: www.paw.eu Installation and Operation Instructions Domestic hot water module

More information

VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 500 l capacity

VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 500 l capacity VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 0 l capacity Datasheet Part no. and prices: see pricelist VITOCELL 300-V Type EVA and EVI Vertical DHW cylinder made from stainless steel 5/2012 Product

More information

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production SATK0 - SATK0 series ACCREDITED ISO 900 FM 009/ GB replaces dp 009/ GB Function The latest generation of Heat Interface

More information

Technical information for installation and operation

Technical information for installation and operation Technical information for installation and operation PR 24002.65 12-04-2016 Subject to technical modifications LogoFresh 100 & 120 fresh water station Electronically controlled GB Meibes System-Technik

More information

24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus

24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus 24-28 kw Conventional Combi Gas Boiler Lawa / LawaPlus Conventional Combi Gas Boilers Warmhaus wall-hung gas combi boilers Lawa and LawaPlus, with the advantage of its width as 288mm, are easily fit to

More information

Since 1983 Nuova COTERM has developed a wide range of water heaters.

Since 1983 Nuova COTERM has developed a wide range of water heaters. Since 1983 Nuova COTERM has developed a wide range of water heaters. Thank to careful attention to market demands and continuous research towards new solutions, Nuova COTERM is able to offer clients the

More information

HIGH EFFICIENCY CIRCULATORS. Represented by Taconova Group AG CATALOGUE 2018 EN. easyuse. greatperformance

HIGH EFFICIENCY CIRCULATORS. Represented by Taconova Group AG CATALOGUE 2018 EN. easyuse. greatperformance HIGH EFFICIENCY CIRCULATORS Represented by Taconova Group AG CATALOGUE 218 EN easyuse greatperformance CONTENTS WELCOME...3 HEATING SYSTEMS ES2 6...4 ES2 7...6 ES2 C A 6...8 ES2 ADAPT 6...1 ES2 ADAPT 7...12

More information

Solar heating systems

Solar heating systems 03 energy efficiency Compact, "ALL-IN-ONE" solar system Solar panel for swimming pools Hydraulic components Drain-Unit: dual hydraulic unit with drain back system Drain-Unit: hydraulic unit with drain-back

More information

SGE Condensing Gas - Solar Water Heater

SGE Condensing Gas - Solar Water Heater Condensing Gas - Solar Water Heater SGE - 0/0 Solar control Fully room-sealed condensing high efficiency gas-solar water heater with integrated solar heat exchanger Maximum solar contribution through fully

More information

HYGIENIK 2.0 WITH HOT WATER STATION 2.0

HYGIENIK 2.0 WITH HOT WATER STATION 2.0 echnical documentation Installation instruction HE ENERGYFAMILY HYGIENIK 2.0 WIH HO WAER SAION 2.0 812556_Rev.3 - Original Instructions HEA PUMPS FROM AUSRIA www.idm-energie.at 2. Contents 1. GENERAL INFORMAION

More information

Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit.!

Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit.! echnical Information- Dishwasher JD51AWP RJDW7A Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit.! CAUION All safety

More information

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l Installation instructions for contractors VIESMANN Vitocell 300-B Type EVBA-A Dual mode DHW cylinder, 300 and 500 l VITOCELL 300-B 1/2017 Dispose after installation. Safety instructions Please follow these

More information

ALL THE BENEFITS OF THE ALL COPPER HEAT EXCHANGER

ALL THE BENEFITS OF THE ALL COPPER HEAT EXCHANGER Yarra s Edge Apartments, Docklands Melbourne RAYPAK Mechanical Heating and Hot Water Green s General Foods, Glendenning. ALL THE BENEFITS OF THE ALL COPPER HEAT EXCHANGER The use of direct fired pure copper

More information

Geolo THE GROUND SOURCE HEAT PUMP PLUSES

Geolo THE GROUND SOURCE HEAT PUMP PLUSES Geolo THE GROUND SOURCE HEAT PUMP PLUSES RENEWABLE TECHNOLOGIES Geolo is able to exploit the Energy present in the water and underground thanks to the geothermal exchangers. Soil and water absorb the solar

More information

Technical documentation. ComfortLine gas condensing boilers CGB-2(K) CGW-2 CGS-2 CSZ-2 NEW

Technical documentation. ComfortLine gas condensing boilers CGB-2(K) CGW-2 CGS-2 CSZ-2 NEW Technical documentation ComfortLine gas condensing boilers CGB-2(K) CGW-2 CGS-2 CSZ-2 NEW ComfortLine gas condensing boilers Benefits of the WOLF gas condensing boilers up to 24 kw CGB-2(K) / CGW-2 / CGS-2

More information

1 VICTRIX ZEUS Superior kw I features

1 VICTRIX ZEUS Superior kw I features Wall-hung condensing VICTRIX ZEUS Superior kw I is the new range of wall-hung condensing boilers with 54 litre stainless steel storage tank available in two versions with nominal heat output of 26 kw and

More information

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOCELL 300-V. Vertical DHW cylinder. 130to500litrecapacity. Vitotec folder, register 17

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOCELL 300-V. Vertical DHW cylinder. 130to500litrecapacity. Vitotec folder, register 17 VIESMANN VITOCELL 300-V Vertical DHW cylinder 130to500litrecapacity Datasheet Part numbers and prices: see pricelist File in: Vitotec folder, register 17 VITOCELL 300-V Type EVA and EVI Vertical DHW cylinder

More information

Stainless Steel Condensing Boiler Connection Instructions To Additional Heating Devices

Stainless Steel Condensing Boiler Connection Instructions To Additional Heating Devices Stainless Steel Condensing Boiler Connection Instructions o Additional Heating Devices Kit #55002875 Kit installation shall be completed by qualified agency.! WARNING Fire, explosion, asphyxiation and

More information

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING MADE IN ITALY residential condensing D.H.W. up to 10 bar WORKING PRESSURE AISI 316 Ti TITANIUM D.H.W. 100% CONDENSING AGUAdens TM wall-mounted water heaters (16-22 -37 litres) AGUAdensTM INSTANTANEOUS

More information

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors infolinia: +48 691 262 691-15 C +63 C +43 C E.V.I. HP The series of high efficiency heat pumps has been specifically designed for use with

More information

Gas condensing boiler

Gas condensing boiler Gas condensing boiler D2CND Welcome to Daikin s high efficiency gas condensing boiler Gas condensing boilers Why choose the Daikin gas condensing boiler? Your customer requires a wall-mounted boiler to:

More information

AQUAMATIC HOT WATER IS YOUR NEW WELLNESS. Instant producer of sanitary hot water

AQUAMATIC HOT WATER IS YOUR NEW WELLNESS. Instant producer of sanitary hot water AQUAMATIC HOT WATER IS YOUR NEW WELLNESS Instant producer of sanitary hot water Aquamatic All the water that you need at the temperature you desire the best AQUAMATIC is the new system for the production

More information

30% Take lead on your project with an efficient system concept. lower energy.

30% Take lead on your project with an efficient system concept. lower energy. Technical handbook Danfoss EvoFlat systems from A-Z Take lead on your project with an efficient system concept 30% lower energy consumption by individual metering in each apartment www.evoflat.danfoss.com

More information

ENERGY TOP. Condensing boiler solutions

ENERGY TOP. Condensing boiler solutions ENERGY TOP Condensing boiler solutions 1 ENERGY TOP > ENERGY TOP RANGE A wide array of flexible solutions both for centralised residential application and big commercial plants The increasing need for

More information

30% Safe. Take lead on your project with an efficient system concept. Technical handbook Danfoss EvoFlat systems from A-Z. evoflat.danfoss.

30% Safe. Take lead on your project with an efficient system concept. Technical handbook Danfoss EvoFlat systems from A-Z. evoflat.danfoss. MAKING MODERN LIVING POSSIBLE Technical handbook Danfoss EvoFlat systems from A-Z Take lead on your project with an efficient system concept Safe and comfortable EvoFlat systems provide heating and domestic

More information

RAYPAK HOT WATER & HEATING

RAYPAK HOT WATER & HEATING All copper & bronze construction On/Off & modulating models High temperature applications RAYPAK HOT WATER & HEATING Raypak is a compact, efficient heating design which is the ideal way to heat large quantities

More information

CALEFFI. Anti-condensation circulation unit. 282 series 01225/14 GB. replaces dp 01225/11. Code completion Setting 45 C 55 C 60 C 70 C.

CALEFFI. Anti-condensation circulation unit. 282 series 01225/14 GB. replaces dp 01225/11. Code completion Setting 45 C 55 C 60 C 70 C. Anti-condensation circulation unit 8 series ACCREDITED ISO 9 F 654 ISO 9 No. CALEFFI 5/4 GB replaces dp 5/ Function The anti-condensation circulation unit performs the function of connecting the solid

More information

VIESMANN. Installation instructions VITOCELL 300-V/W. for contractors. Vitocell 300-V/W Type EVIA-A

VIESMANN. Installation instructions VITOCELL 300-V/W. for contractors. Vitocell 300-V/W Type EVIA-A Installation instructions for contractors VIESMNN Vitocell 300-V/W Type EVI- DHW cylinder with internal indirect coil 160 to 500 l VITOCELL 300-V/W 3/2017 Dispose after installation. Safety instructions

More information

Valves, controls + systems. Innovation + Quality. Stations for solar energy and solid fuel boilers Product range

Valves, controls + systems. Innovation + Quality. Stations for solar energy and solid fuel boilers Product range Valves, controls + systems Innovation + Quality Stations for solar energy and solid fuel boilers Product range Stations for solar energy and solid fuel boilers Content Page Summary Stations for solar energy

More information

ECOplus Solar Cylinder

ECOplus Solar Cylinder TECHNICAL INFORMATION ECOplus Solar Cylinder Minimized Heat Loss due to convection brakes in the pipe connections, the new close-fitting, 00-mm thick PU soft foam jacket insulation, 0-mm thick and close

More information

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 The XB is a brazed plate heat exchanger designed for use with district heating systems (i.e. air conditioning,

More information

VICTRIX Superior kw Export VICTRIX Superior kw X Export

VICTRIX Superior kw Export VICTRIX Superior kw X Export Wall-hung condensing VICTRIX Superior kw is the instantaneous sealed chamber wallhung boiler with power of 32 kw which, thanks to condensation technology, is characterised for its high efficiency and guarantees

More information

RVL471. Heating controller. G2524en. Installation Instructions. 1 Installation. 2 Commissioning

RVL471. Heating controller. G2524en. Installation Instructions. 1 Installation. 2 Commissioning G2524en Heating controller Installation Instructions RVL471 1 Installation 1.1 Place of installation In a dry room, e.g. the boiler room Mounting choices: In a control panel (on the inner wall or on a

More information

Technical Data Sheet for Sunergy SOLAR ENERGY PROCESSOR Model SEP3G10

Technical Data Sheet for Sunergy SOLAR ENERGY PROCESSOR Model SEP3G10 Technical Data Sheet for Sunergy SOLAR ENERGY PROCESSOR Model SEP3G1 Minus7 equipment and Systems are to be designed, installed and maintained by Minus7 personnel only. Contents General Description! 2

More information

Sirius FS. Working towards a cleaner future

Sirius FS. Working towards a cleaner future Sirius FS Floor Standing Stainless Steel Condensing Boilers Single Boiler Applications: 50 to 160kW Modular Boiler Applications: up to 640kW Working towards a cleaner future heating specialists 1. Product

More information

FREQUENTLY ASKED QUESTIONS

FREQUENTLY ASKED QUESTIONS FREQUENTLY ASKED QUESTIONS DRAIN WATER HEAT RECOVERY... 2 What is drain water heat recovery?... 2 Why is it important to recover heat from drain water?... 2 ZYPHO TECHNOLOGY... 2 How does ZYPHO work?...

More information

WOLF WALL MOUNTED GAS CONDENSING BOILERS COMFORTLINE

WOLF WALL MOUNTED GAS CONDENSING BOILERS COMFORTLINE WOLF WALL MOUNTED GAS CONDENSING BOILERS COMFORTLINE CGB-2(K) / CGW-2 / CGS-2L / CGS-2R / CSZ-2 30m 3 /h THE EXTENSIVE EQUIPMENT RANGE from system supplier WOLF offers the ideal solution for commercial

More information

Immersion Temperature Controller

Immersion Temperature Controller 3 333 Synco 100 Immersion emperature Controller with 2 outputs DC 0 RLE162 Immersion temperature controller for water-side control in heating and cooling plants Compact design with 2 analog control outputs

More information

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw Superior A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler Outputs 120, 160, 200, 240, 280 kw 1 The Superior is a, pre-assembled floor standing, gas fired high efficiency

More information

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB 4 RESET ON DHW CH FAULT SATK wall-mounted heat interface unit Fitted for connection to DHW storage SATK4 series ACCREDITED CALEFFI 6/4 GB ISO 9 FM 64 ISO 9 No. The latest generation of heat interface units

More information

PZ35RL BIOTECH THE FUTURE OF HEATING PZ 35 RL

PZ35RL BIOTECH THE FUTURE OF HEATING PZ 35 RL BIOTECH THE FUTURE OF HEATING PZ 35 RL Heating with renewable energies is the future and you will not only contribute to the environment, you also will reduce massively your annual energy cost. The Biotech

More information

HIGH-POWER HEAT PUMPS. Up to 300 kw

HIGH-POWER HEAT PUMPS. Up to 300 kw HIGH-POWER HEAT PUMPS Up to 300 kw 1 2 NEW GENERATION OF HEAT PUMPS GORENJE 4 COMPLETE RANGE OF NEW GENERATION HIGH-POWER HEAT PUMPS 8 MODERN CONTROL UNIT HEAT PUMPS AIR-WATER 10 Heat pumps AEROGOR COMPACT

More information

VIESMANN. Service instructions VITOCELL 300-B VITOCELL 300-V. for contractors

VIESMANN. Service instructions VITOCELL 300-B VITOCELL 300-V. for contractors Service instructions for contractors VIESMANN Vitocell 300-B Type EVB DHW cylinder, 300 and 500 l Vitocell 300-V Type EVI DHW cylinder, 200 to 500 l For applicability, see the last page VITOCELL 300-B

More information

Meibes Heat Interface Unit (HIU) A2RXE Instantaneous Hot Water & Space Heating

Meibes Heat Interface Unit (HIU) A2RXE Instantaneous Hot Water & Space Heating Meibes Heat Interface Unit (HIU) A2RXE Instantaneous Hot Water & Space Heating Product code A2RXE Founded in 1975 by Jan Aalberts. The enterprise has grown to an organisational structure in which group

More information

Tank systems. Layered tank Solar layered tank Hygienic layered tank Modular layered tank Hot water tank NEW:

Tank systems. Layered tank Solar layered tank Hygienic layered tank Modular layered tank Hot water tank NEW: Tank systems Layered tank Solar layered tank Hygienic layered tank Modular layered tank Hot water tank NEW: NEOPOR AND FLEECE INSULATION SENSOR TERMINAL STRIP ADJUSTABLE FEET www.froeling.com Energy management

More information

TA-MATIC. Mixing valves Thermostatic mixing valve for domestic hot water

TA-MATIC. Mixing valves Thermostatic mixing valve for domestic hot water TA-MATIC Mixing valves Thermostatic mixing valve for domestic hot water IMI TA / Potable water / TA-MATIC TA-MATIC Thermostatic mixing valve for control of domestic hot water systems in apartment blocks

More information

FRISTAR2-WP Fresh water station for heat pumps

FRISTAR2-WP Fresh water station for heat pumps www.ta.co.at FRISTAR2-WP Fresh water station for heat pumps Operating manual Manual Version 1.03 English Table of contents Safety instructions...4 Mode of operation...5 Hydraulic circuit diagram... 5

More information

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C ALKON 50 C ALKON 70 C WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) OUTPUT RANGE from 50 to 560 kw (in battery) WORKING TEMPERATURE no limit on

More information

Bosch. Gas Condensing Boiler. Applications Manual. 100, 151 Combi Boiler 57, 100, 131, 151 Heating Boiler

Bosch. Gas Condensing Boiler. Applications Manual. 100, 151 Combi Boiler 57, 100, 131, 151 Heating Boiler WARNING: Improper installation, setup, modification, operation or maintenance of the heating system can cause personal injury and property damage. Follow each appliances' instructions precisely. For assistance

More information

TopVent Design Handbook

TopVent Design Handbook TopVent Design Handbook Recirculation Units and Supply Air Units for Heating and Cooling High Spaces TopVent Content TopVent DHV Recirculation unit for heating high spaces TopVent NHV Recirculation unit

More information

C Nias Dual. Wall-hung boilers, forced draught, sealed chamber with storage tank. For indoor installation. Life-enhancing heat

C Nias Dual. Wall-hung boilers, forced draught, sealed chamber with storage tank. For indoor installation. Life-enhancing heat C 223-01 made in Italy Nias Dual Wall-hung boilers, forced draught, sealed chamber with storage tank. For indoor installation. Life-enhancing heat GB Wall-hung boilers, forced draught, sealed chamber with

More information

A Evaporator B Fan C Terminal box D Hermetically sealed, output regulated digital scroll compressor E Condenser

A Evaporator B Fan C Terminal box D Hermetically sealed, output regulated digital scroll compressor E Condenser Vitocal 300-A, type AWC-I and AW-O.1 Product description A Evaporator B Fan C Terminal box D Hermetically sealed, output regulated digital scroll compressor E Condenser & High operational reliability,

More information

RMG MK. II RMG Mk.II RS Mk.II RMG Mk.II RS Mk.II

RMG MK. II RMG Mk.II RS Mk.II RMG Mk.II RS Mk.II Caldaie a basamento RMG Mk.II and RS Mk.II gas boilers are cast-iron made and are developed and manufactured in order to meet the demands of heating installations of middle and high output, thanks to the

More information

High-output calorifier Modul-plus

High-output calorifier Modul-plus High-output calorifier Modul-plus Favourite choice für refined domestic hot water convenience. 1 Modul-plus. Advantages at a glance It is the favourite choice for refined hot water convenience in renowned

More information

24/31-28/35-33/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus.

24/31-28/35-33/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus. combi boilers panel radiators 24/31-28/35-33/40 kw Premix System Condensing Combi Gas Boilers Priwa / PriwaPlus www.warmhaus.com 1 Premix System Condensing Combi Gas Boilers 24/31-28/35-33/40 kw Warmhaus

More information

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with two or three CM, CMV or CR pumps. 50 Hz

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with two or three CM, CMV or CR pumps. 50 Hz GRUNDFOS DATA BOOKLET Grundfos booster systems with two or three CM, CMV or CR pumps 50 Hz Table of contents 1. Product introduction 3 2. Performance range 4 with CM pumps 4 with CMV pumps 4 with CR pumps

More information

SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS

SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS INDEX Ed. 20150422 GENERAL INFORMATION... 2 Before installing... 2 Materials and PED (97/23/CE) Standards... 3 SKID-TYPE DISTRICT HEATING

More information

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus. 24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers Enerwa / EnerwaPlus www.warmhaus.com Condensing-ErP Premix System Boilers 24/31-28/35-33/40 kw Warmhaus wall-hung gas combi boilers

More information

Condensing, pre-mixed, wall-hung gas boilers with water tank

Condensing, pre-mixed, wall-hung gas boilers with water tank C 271-01 made in Italy Nias condensing Condensing, pre-mixed, wall-hung gas boilers with water tank Life-enhancing heat GB Condensing, pre-mixed, wall-hung boilers with water tank Nias CONDENSING HIGH

More information

Broag Pressurisation equipment

Broag Pressurisation equipment Broag Pressurisation equipment Compact wall mounted and free standing pressurisation units, utilising the latest microprocessor control. For use on sealed heating and cooling systems, offering accurate

More information

ThermoClean Domestic water heating system with legionella growth prevention through thermal disinfection

ThermoClean Domestic water heating system with legionella growth prevention through thermal disinfection ThermoClean Domestic water heating system with legionella growth prevention through thermal disinfection Description/Application The ThermoClean system is compact and effective solution for legionella-free

More information

ALKON 90 ALKON 90 MODEL 24,0 93,6 21,1 87, nominal heat output. conventional. max/min heat input. efficiency class (Directive 92/42)

ALKON 90 ALKON 90 MODEL 24,0 93,6 21,1 87, nominal heat output. conventional. max/min heat input. efficiency class (Directive 92/42) ALKON 90 ALKON 90 MODEL max/min condensing nominal heat output conventional max/min heat input efficiency class (Directive 92/42) kw kw kw ALKON 90 24,0 93,6 21,1 87,5 22-90 Moving in the present with

More information

TS RD 7761 RD, 7761 RD

TS RD 7761 RD, 7761 RD 1/2 HERZ Calis TS RD three way valve HERZ Calis TS RD 100% three-way valve for heating and cooling Datasheet for 1 7761 RD, Issue 0716 Dimensions in mm Order number Dimension R A B C kvs dp (bar) maximum

More information

General catalogue COMMERCIAL AND TECHNICAL INFORMATION. Commercial Range. March 2015 Edition

General catalogue COMMERCIAL AND TECHNICAL INFORMATION. Commercial Range. March 2015 Edition General catalogue COMMERCIAL AND TECHNICAL INFORMATION Commercial Range March 2015 Edition Company Profile BAXI SPA has a proud tradition of developing and producing boilers and heating systems to the

More information

GENERAL INFORMATIONS

GENERAL INFORMATIONS GENERAL INFORMATIONS Devices only operate in cooling mode. Enviromental-friendly R407c coolant is utilized in standard products. The system can be created with various coolants depending on the water temperature

More information

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers 5 YEAR WARRANTY ADVANCE PLUS High efficiency condensing combi and system boilers Android Apple WALL HUNG BOILERS Advance Plus ADVANCE PLUS HIGH EFFICIENCY BOILER RANGE The Advance Plus range is the latest

More information

Economy Standard Comfort. Heat loss (W/K) Heat loss (kwh/24h) (3)

Economy Standard Comfort. Heat loss (W/K) Heat loss (kwh/24h) (3) 4 Technical Data The following tables and drawings provide an overview of the most important dimensions and properties of Solvis- Max Gas and SolvisMax Gas Pur. 4.1 Volumes and heat loss SX-356 SX-456

More information

C Tahiti. condensing

C Tahiti. condensing C 227-01 m a d e i n I ta ly Tahiti condensing Condensing, pre-mixed, wall-hung boilers KC 24 KC 28 - KC 32 indoor, instantaneous, combination boilers KR 24 KR 38 - KR 32 indoor, central heating only boilers

More information

AQUAFIT - the innovative single-lever mixer for safety and hygiene

AQUAFIT - the innovative single-lever mixer for safety and hygiene Night & Day: DRINKING-WATER HYGIENE AQUAFIT - the innovative single-lever mixer for safety and hygiene Maximum protection, maximum hygiene Preserving water quality in all drinking water installations For

More information

FEATURES AND BENEFITS. Up to 109.8% part load efficiency

FEATURES AND BENEFITS. Up to 109.8% part load efficiency IMAX XTRA EL. 320kW FLOOR STANDING CONDENSING The Imax Xtra EL range of condensing boilers is available in 5 models with outputs from 320 to 620kW. Suitable for floor standing applications in either single

More information

Installation instructions

Installation instructions 2Power storage tank Installation instructions This installation construction contains important advice for handling, installing and starting up a 2Power solar plant. Read these advice carefully before

More information

TACOTHERM FRESH PETA / PETA X

TACOTHERM FRESH PETA / PETA X TACOTHERM FRESH PETA / PETA X FRESH WATER STATION V01.2017 01/2017 Item no. 212515 EA no. 1226 OPERATING INSTRUCTIONS CONTACT AND ADDITIONAL INFORMATION WWW.TACONOVA.COM Taconova Group AG 2016 Neubrunnenstrasse

More information

Kitchen Water Dispenser

Kitchen Water Dispenser HOT & COLD WATER DISPENSER Article number: 17861875 Max. flow 2 l/min at 3 bar flow ready-to-use control unit for wall mounting (135 mm x 160 mm x 60 mm) electronic magnetic valve 100-230 V, 50-60 Hz,

More information

BWA. CONDENSING WALL HUNG BOILER FROM 50 kw TO 140 kw

BWA. CONDENSING WALL HUNG BOILER FROM 50 kw TO 140 kw BWA CONDENSING WALL HUNG BOILER FROM 50 kw TO 140 kw Professional From 50 kw to 70 kw EFFICIENCY CLASS (CE DIR. 92 / 42). Seasonal efficiencies up to 109% CLASS 5 Low NO x (EN 483) thanks to the pre-mixed

More information

Logamax plus GB172/GB172T. Heat is our element. Technical Guide Issue 2011/06. Fügen Sie auf der Vorgabeseite das zur Produktgruppe passende Bild ein.

Logamax plus GB172/GB172T. Heat is our element. Technical Guide Issue 2011/06. Fügen Sie auf der Vorgabeseite das zur Produktgruppe passende Bild ein. Technical Guide Issue 2011/06 Fügen Sie auf der Vorgabeseite das zur Produktgruppe passende Bild ein. Sie finden die Bilder auf der Referenzseite 14: Buderus Product groups. Anordnung im Rahmen: - Tops

More information

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW Stainless steel range of condensing boilers Outputs from 50kW to 660kW Designed to meet carbon reduction targets Lifetime service and support Totally dependable. page 1 www.pottertoncommercial.co.uk Contents

More information

ACCUMULATION OF EUROPEAN CLASS

ACCUMULATION OF EUROPEAN CLASS ACCUMULATION OF EUROPEAN CLASS Total comfort MODEL nominal output kw minimum output kw DUA PLUS B TN DUA PLUS B TFS natural draught room sealed forced draught 28 12.4 28 12.4 DUA PLUS B was born from the

More information

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS THE UK'S ONLY NOx CLASS 6 RATED FLOOR STANDING BOILER IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING The Imax Xtra EL range of dual condensing boilers is available in 5 models with outputs from 715 to 1240kW.

More information

VIESMANN VITOROND 100. Datasheet Part numbers and prices: see pricelist VITOROND 100. Cast iron low temperature oil and gas fired boiler.

VIESMANN VITOROND 100. Datasheet Part numbers and prices: see pricelist VITOROND 100. Cast iron low temperature oil and gas fired boiler. VIESMANN VITOROND 100 Cast iron low temperature oil and gas fired boiler 40 to 100 kw Datasheet Part numbers and prices: see pricelist File in: Vitotec folder, register 1 VITOROND 100 Type VR2B Cast iron

More information

Storage tank size Rated volume [l] Actual volume [l]

Storage tank size Rated volume [l] Actual volume [l] 10 Technical Data Volumes and heat loss Storage tank size 356 456 656 756 956 Rated volume [l] 350 450 650 750 950 Actual volume [l] 365 448 623 695 886 Hot water standby volume [l] Economy Standard Comfort

More information

ARGO AR SERIES CONTROLS

ARGO AR SERIES CONTROLS ARGO AR SERIES CONROLS AR822-II, AR861-2II, AR861-3II INSALLAION, OPERAION & MAINENANCE MANUAL AR861-2II AR822-II AR861-3II Information and specifications outlined in this manual in effect at the time

More information

LZT High efficiency air to water heat pumps with E.V.I. compressors

LZT High efficiency air to water heat pumps with E.V.I. compressors High efficiency air to water heat pumps with E.V.I. compressors -20 C +43 C +65 C E.V.I. C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating

More information

CALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB

CALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB Set point thermostatic regulating unit 8 series FM 65 00 CALEFFI 090/8 GB replaces dp 090/5 GB Function The thermostatic regulating unit is made to be used in radiant panel systems, in combination with

More information

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control. product selection data Compact comfort module DHW management possibility Multi zone option control Easy installation Comfort module with two-zone kit Single-zone comfort module Comfort Module Range for

More information

RAYPAK HOT WATER & HEATING

RAYPAK HOT WATER & HEATING All copper & bronze construction On/Off & modulating models High temperature applications RAYPAK HOT WATER & HEATING Raypak is a compact, efficient heating design which is the ideal way to heat large quantities

More information