HIGH EFFICIENCY CIRCULATORS. Represented by Taconova Group AG CATALOGUE 2018 EN. easyuse. greatperformance

Size: px
Start display at page:

Download "HIGH EFFICIENCY CIRCULATORS. Represented by Taconova Group AG CATALOGUE 2018 EN. easyuse. greatperformance"

Transcription

1 HIGH EFFICIENCY CIRCULATORS Represented by Taconova Group AG CATALOGUE 218 EN easyuse greatperformance

2 CONTENTS WELCOME...3 HEATING SYSTEMS ES ES ES2 C A ES2 ADAPT ES2 ADAPT SOLAR THERMAL ES2 SOLAR ES2 SOLAR DOMESTIC HOT WATER ES2 PURE C PRICE LIST...2 GLOSSARY...22 SALES PARTNER...23 ES2 ES2 Adapt ES2 Solar ES2 PURE C 2

3 WELCOME Last year, the Taco Family of Companies based in Cranston, USA, acquired the Taconova Group AG. This fusion of two companies effectively closed the circle that began in 1961 when Taconova was founded by Taco. As of March 218, Taco circulation pumps are now being marketed in Germany, Austria and Switzerland by Taconova. The range of pumps produced by Taco Italia covers the following three application areas: HEATING SOLAR THERMAL DHW CIRCULATION Taco circulation pumps are characterised by permanent magnet synchronous motors, which ensure high efficiency and low operating costs, as well as meeting new energy regulations. The glandless circulation pumps demonstrate all the benefits of this type of design: No maintenance Replacement of sealing elements not necessary Reliable operation Further benefits of Taco circulation pumps: Internal motor protection which automatically shuts the pump down if excess voltage, short circuit, overheating or dry running should occur Automatic venting function to remove air from the pump Auto unlock automatic anti-seizing function which loosens dirt particles in the pump through vibrations You can now also contact the Taconova Sales and Service Network for all your requirements and questions relating to circulation pumps. Taconova Where comfort begins

4 ENERGY SAVING ES2 6 The adjustment is simple and intuitive: simply turn the regulator to select the desired program Pull-out resistant cable gland with integrated sealing lip Flat surfaces on the pump housing provide a secure hold when tightening APPLICATION Hot-water heating systems of all kinds, in domestic and commercial buildings. ENERGY EFFICIENCY INDEX EEI,2 - Part 2* MOTOR TECHNICAL DATA Power supply 1x23 V ( ±1%); Frequency: /6 Hz Electrical connection Pull resistant cable clamp PG11 Input power (P 1 ) Min. 3W, Max. 42W Input current (I 1 ) Min..3A, Max..33A Insulation class H Protection class IP44 Appliance class II PUMP TECHNICAL DATA Ambient temperature Allowed liquid temperature ** Temperature range at max. ambient temperature Operating pressure Minimum pressure on the intake opening from + C to +4 C from +2 C to +9 C of 3 C = +3 C to +9 C of 3 C = +3 C to +9 C of 4 C = +4 C to +7 C Max..6 MPa - 6 bar.3 MPa (.3 bar) at C.1 MPa (1. bar) at 9 C Maximum relative humidity 9% Sound pressure level < 43 db(a) Low Voltage directive (26/9/CE) Standard used: EN 62233, EN and EN EMC Directive (24/18/CE) Standard used: EN and EN , EN 14-1 and EN 14-2 Ecodesign Directive (29/12/CE) Standard used: EN and EN TYPE KEY * The benchmark for most efficient circulators is EEI,2. ** To avoid condensation in the motor and electronics the temperature of the pumped liquid must always be greater than the ambient temperature. Example Electronic circulator Standard version ADAPT: Version with activeadapt SOLAR: Solar thermal version PURE: MAXI: DHW version HVAC systems version Cast-iron pump housing C: Composite pump housing B: Bronze pump housing A: Pump housing with air separator Noal diameter (DN) of suction and discharge ports [mm] Maximum head [dm] Port-to-port length [mm] ES2 2 6 / 18 4

5 PERFORMANCE CURVES AND PUMP SETTINGS 1 1 Q [US.gpm] 1 Q [IMS.gpm] H [m] H [ft] 6 max 2 - max CII CI P2 P Q [m 3 /h] Q [l/s] MATERIALS MODEL Pump housing Impeller Shaft Bearing Thrust bearing Rotor can ES2 6 Cast iron EN-GJL-2 with cataphoretic coating (KTL) Composite Ceramic Carbon Ceramic Composite DIMENSIONS, WEIGHTS H1 H B H2 B1 B2 L H3 G B3 MODEL THREAD DIMENSIONS [mm] WEIGHTS [Kg] G L B B1 B2 B3 H H1 H2 H3 Net Gross ES2 1-6/13 G ,8 29,4 14,4 49 1,67 1,87 ES2 2-6/13 G 1 ½ ,8 29,4 14,4 49 1,81 2,1 ES2 2-6/18 G 1 ½ ,8 29,4 14,4 49 1,96 2,6 ES2 32-6/18 G ,8 29,4 14,4 49 2,1 2,3 HEATING

6 ENERGY SAVING ES2 7 The adjustment is simple and intuitive: simply turn the regulator to select the desired program Pull-out resistant cable gland with integrated sealing lip Flat surfaces on the pump housing provide a secure hold when tightening APPLICATION Hot-water heating systems of all kinds, in domestic and commercial buildings. ENERGY EFFICIENCY INDEX EEI,21 - Part 2* MOTOR TECHNICAL DATA Power supply 1x23 V ( ±1%); Frequency: /6 Hz Electrical connection Pull resistant cable clamp PG11 Input power (P 1 ) Min. 3W, Max. 6W Input current (I 1 ) Min..3A, Max..44A Insulation class H Protection class IP44 Appliance class II PUMP TECHNICAL DATA Ambient temperature Allowed liquid temperature ** Temperature range at max. ambient temperature Operating pressure Minimum pressure on the intake opening from + C to +4 C from +2 C to +9 C of 3 C = +3 C to +9 C of 3 C = +3 C to +9 C of 4 C = +4 C to +7 C Max..6 MPa - 6 bar.3 MPa (.3 bar) at C.1 MPa (1. bar) at 9 C Maximum relative humidity 9% Sound pressure level < 43 db(a) Low Voltage directive (26/9/CE) Standard used: EN 62233, EN and EN EMC Directive (24/18/CE) Standard used: EN and EN , EN 14-1 and EN 14-2 Ecodesign Directive (29/12/CE) Standard used: EN and EN TYPE KEY * The benchmark for most efficient circulators is EEI,2. ** To avoid condensation in the motor and electronics the temperature of the pumped liquid must always be greater than the ambient temperature. Example Electronic circulator Standard version ADAPT: Version with activeadapt SOLAR: Solar thermal version PURE: MAXI: DHW version HVAC systems version Cast-iron pump housing C: Composite pump housing B: Bronze pump housing A: Pump housing with air separator Noal diameter (DN) of suction and discharge ports [mm] Maximum head [dm] Port-to-port length [mm] ES2 2 7 / 18 6

7 PERFORMANCE CURVES AND PUMP SETTINGS H [m] 1 1 Q [US.gpm] 1 Q [IMS.gpm] H [ft] 7 6 max 2 - max CII CI P2 P Q [m 3 /h] Q [l/s] MATERIALS MODEL Pump housing Impeller Shaft Bearing Thrust bearing Rotor can ES2 7 Cast iron EN-GJL-2 with cataphoretic coating (KTL) Composite Ceramic Carbon Ceramic Composite DIMENSIONS, WEIGHTS H1 H B H2 B1 B2 L H3 G B3 MODEL THREAD DIMENSIONS [mm] WEIGHTS [Kg] G L B B1 B2 B3 H H1 H2 H3 Net Gross ES2 1-7/13 G ,8 29,4 114,4 49 1,91 2,11 ES2 2-7/13 G 1 ½ ,8 29,4 114,4 49 2, 2,2 ES2 2-7/18 G 1 ½ ,8 29,4 114,4 49 2,2 2,4 ES2 32-7/18 G ,8 29,4 114,4 49 2,34 2,4 HEATING 7

8 ENERGY SAVING ES2 C A 6 Compact design and easy installation Pull-out resistant cable gland with integrated sealing lip Pump housing realized in composite plastic material with air separator APPLICATION Hot-water heating systems of all kinds, in domestic and commercial buildings. ENERGY EFFICIENCY INDEX EEI,23 - Part 2* MOTOR TECHNICAL DATA Power supply 1x23 V ( ±1%); Frequency: /6 Hz Electrical connection Pull resistant cable clamp PG11 Input power (P 1 ) Min. 3W, Max. 42W Input current (I 1 ) Min..3A, Max..33A Insulation class H Protection class IP44 Appliance class II PUMP TECHNICAL DATA Ambient temperature Allowed liquid temperature** Temperature range at max. ambient temperature Operating pressure from + C to +4 C from +2 C to +9 C of 3 C = +3 C to +9 C of 3 C = +3 C to +9 C of 4 C = +4 C to +7 C Max..6 MPa - 6 bar Minimum pressure on the intake opening.3 MPa (.3 bar) at C.1 MPa (1. bar) at 9 C Maximum relative humidity 9% Sound pressure level < 43 db(a) Low Voltage directive (26/9/CE) Standard used: EN 62233, EN and EN EMC Directive (24/18/CE) Standard used: EN , EN , EN 14-1 and EN 14-2 Ecodesign Directive (29/12/CE) Standard used: EN and EN TYPE KEY * The benchmark for most efficient circulators is EEI,2. ** To avoid condensation in the motor and electronics the temperature of the pumped liquid must always be greater than the ambient temperature. Example Electronic circulator Standard version ADAPT: Version with activeadapt SOLAR: Solar thermal version PURE: MAXI: DHW version HVAC systems version Cast-iron pump housing C: Composite pump housing B: Bronze pump housing A: Pump housing with air separator Noal diameter (DN) of suction and discharge ports [mm] Maximum head [dm] Port-to-port length [mm] ES2 C A 1 6 / 13 8

9 PERFORMANCE CURVES AND PUMP SETTINGS 1 1 Q [US.gpm] 1 Q [IMS.gpm] H [m] H [ft] 6 max 2 - max 4 CII 1 3 CI 1 2 P2 1 P Q [m 3 /h] Q [l/s] MATERIALS MODEL Pump housing Impeller Shaft Bearing Thrust bearing Rotor can ES2 C A 6 PA 66 GF Composite Composite Ceramic Carbon Ceramic Composite DIMENSIONS, WEIGHTS H1 H H2 B1 B2 B L L1 G MODEL THREAD DIMENSIONS [mm] WEIGHTS [Kg] G L L1 B B1 B2 H H1 H2 Net Gross ES2 C A 1-6/13 G , 1, 44 6, 161,4 8,7 12,7 1,2 1,4 HEATING 9

10 ENERGY SAVING ES2 ADAPT 6 activeadapt function: pump rate automatically adjusted to the specific requirements of the system Efficient output adjustment with variable Δp-v, constant proportional pressure Δp-c or fixed./max. speed Wide range of temperature from +2 C to +11 C Thermal insulation shell included APPLICATION Hot-water heating systems of all kinds, in domestic and commercial buildings. ENERGY EFFICIENCY INDEX EEI,2 - Part 2* MOTOR TECHNICAL DATA Power supply 1x23 V ( ±1%); Frequency: /6 Hz Electrical connection Pull resistant cable clamp PG11 Input power (P 1 ) Min. 3W, Max. 42W Input current (I 1 ) Min..3A, Max..33A Insulation class H Protection class IP44 Appliance class II PUMP TECHNICAL DATA Ambient temperature Allowed liquid temperature** Temperature range at max. ambient temperature Operating pressure from + C to +4 C from +2 C to +11 C of 3 C = +3 C to +11 C of 3 C = +3 C to +9 C of 4 C = +4 C to +7 C Max. 1. MPa - 1 bar Minimum pressure on the intake opening.3 MPa (.3 bar) at C.1 MPa (1. bar) at 9 C.1 MPa (1. bar) at 11 C Maximum relative humidity 9% Sound pressure level < 43 db(a) Low Voltage directive (26/9/CE) Standard used: EN 62233, EN and EN EMC Directive (24/18/CE) Standard used: EN , EN , EN 14-1 and EN 14-2 Ecodesign Directive (29/12/CE) Standard used: EN and EN TYPE KEY * The benchmark for most efficient circulators is EEI,2. ** To avoid condensation in the motor and electronics the temperature of the pumped liquid must always be greater than the ambient temperature. Example Electronic circulator Standard version ADAPT: Version with activeadapt SOLAR: Solar thermal version PURE: MAXI: DHW version HVAC systems version Cast-iron pump housing C: Composite pump housing B: Bronze pump housing A: Pump housing with air separator Noal diameter (DN) of suction and discharge ports [mm] Maximum head [dm] Port-to-port length [mm] ES2 Adapt 1 6 / 13 1

11 PERFORMANCE CURVES AND PUMP SETTINGS 1 1 Q [US.gpm] 1 Q [IMS.gpm] H [m] H [ft] 6 max 2 activeadapt - max 4 3 CIII CII P3 P2 1 1 activeadapt 2 1 CI P1 activeadapt Q [m 3 /h] Q [l/s] MATERIALS MODEL Pump housing Impeller Shaft Bearing Thrust bearing Rotor can ES2 ADAPT 6 Cast iron EN-GJL-2 with cataphoretic coating (KTL) Composite Ceramic Carbon Ceramic Composite DIMENSIONS, WEIGHTS H1 H B H2 B1 B2 L H3 G B3 MODEL THREAD DIMENSIONS [mm] WEIGHTS [Kg] G L B B1 B2 B3 H H1 H2 H3 Net Gross ES2 ADAPT 1-6/13 G ,8 29,4 14,4 49 1,67 2,2 ES2 ADAPT 2-6/13 G 1 ½ ,8 29,4 14,4 49 1,81 2,16 ES2 ADAPT 2-6/18 G 1 ½ ,8 29,4 14,4 49 1,96 2,31 ES2 ADAPT 32-6/18 G ,8 29,4 14,4 49 2,1 2,4 HEATING 11

12 ENERGY SAVING ES2 ADAPT 7 activeadapt function: pump rate automatically adjusted to the specific requirements of the system Efficient output adjustment with variable Δp-v, constant proportional pressure Δp-c or fixed./max. speed Wide range of temperature from +2 C to +11 C Thermal insulation shell included APPLICATION Hot-water heating systems of all kinds, in domestic and commercial buildings. ENERGY EFFICIENCY INDEX EEI,21 - Part 2* MOTOR TECHNICAL DATA Power supply 1x23 V ( ±1%); Frequency: /6 Hz Electrical connection Pull resistant cable clamp PG11 Input power (P 1 ) Min. 3W, Max. 6W Input current (I 1 ) Min..3A, Max..44A Insulation class H Protection class IP44 Appliance class II PUMP TECHNICAL DATA Ambient temperature Allowed liquid temperature** Temperature range at max. ambient temperature Operating pressure Minimum pressure on the intake opening from + C to +4 C from +2 C to +11 C of 3 C = +3 C to +11 C of 3 C = +3 C to +9 C of 4 C = +4 C to +7 C Max. 1. MPa - 1 bar.3 MPa (.3 bar) at C.1 MPa (1. bar) at 9 C.1 MPa (1. bar) at 11 C Maximum relative humidity 9% Sound pressure level < 43 db(a) Low Voltage directive (26/9/CE) Standard used: EN 62233, EN and EN EMC Directive (24/18/CE) Standard used: EN , EN , EN 14-1 and EN 14-2 Ecodesign Directive (29/12/CE) Standard used: EN and EN TYPE KEY * The benchmark for most efficient circulators is EEI,2. ** To avoid condensation in the motor and electronics the temperature of the pumped liquid must always be greater than the ambient temperature. Example Electronic circulator Standard version ADAPT: Version with activeadapt SOLAR: Solar thermal version PURE: MAXI: DHW version HVAC systems version Cast-iron pump housing C: Composite pump housing B: Bronze pump housing A: Pump housing with air separator Noal diameter (DN) of suction and discharge ports [mm] Maximum head [dm] Port-to-port length [mm] ES2 Adapt 1 7 / 13 12

13 PERFORMANCE CURVES AND PUMP SETTINGS H [m] 7 max 1 1 Q [US.gpm] 1 Q [IMS.gpm] H [ft] activeadapt max 4 CIII CII P3 P2 1 activeadapt 3 2 CI P1 activeadapt Q [m 3 /h] Q [l/s] MATERIALS MODEL Pump housing Impeller Shaft Bearing Thrust bearing Rotor can ES2 ADAPT 7 Cast iron EN-GJL-2 with cataphoretic coating (KTL) Composite Ceramic Carbon Ceramic Composite DIMENSIONS, WEIGHTS H1 H B H2 B1 B2 L H3 G B3 MODEL THREAD DIMENSIONS [mm] WEIGHTS [Kg] G L B B1 B2 B3 H H1 H2 H3 Net Gross ES2 ADAPT 1-7/13 G ,8 29,4 114,4 49 1,91 2,26 ES2 ADAPT 2-7/13 G 1 ½ ,8 29,4 114,4 49 2, 2,4 ES2 ADAPT 2-7/18 G 1 ½ ,8 29,4 114,4 49 2,2 2, ES2 ADAPT 32-7/18 G ,8 29,4 114,4 49 2,34 2,69 HEATING 13

14 ENERGY SAVING ES2 SOLAR 6 A LED provides information about the operation status of the circulator Wide range of temperature from +2 C to +11 C, suitable for circulation in solar thermal systems The pump housing is cataphoresis treated (KTL) and resistant to corrosion APPLICATION Renewable energy solar thermal systems, biomass boilers and hot water heating systems of any kind. ENERGY EFFICIENCY INDEX EEI,2 - Part 2* MOTOR TECHNICAL DATA Power supply 1x23 V ( ±1%); Frequency: /6 Hz Electrical connection Pull resistant cable clamp PG11 Input power (P 1 ) Min. 3W, Max. 42W Input current (I 1 ) Min..3A, Max..33A Insulation class H Protection class IP44 Appliance class II PUMP TECHNICAL DATA Ambient temperature Allowed liquid temperature ** Temperature range at max. ambient temperature Operating pressure Minimum pressure on the intake opening from + C to +4 C from +2 C to +11 C of 3 C = +3 C to +11 C of 3 C = +3 C to +9 C of 4 C = +4 C to +7 C Max. 1. MPa - 1 bar.3 MPa (.3 bar) at C.1 MPa (1. bar) at 9 C.1 MPa (1. bar) at 11 C Maximum relative humidity 9% Sound pressure level < 43 db(a) Low Voltage directive (26/9/CE) Standard used: EN 62233, EN and EN EMC Directive (24/18/CE) Standard used: EN and EN , EN 14-1 and EN 14-2 Ecodesign Directive (29/12/CE) Standard used: EN and EN TYPE KEY * The benchmark for most efficient circulators is EEI,2. ** To avoid condensation in the motor and electronics the temperature of the pumped liquid must always be greater than the ambient temperature. Example Electronic circulator Standard version ADAPT: Version with activeadapt SOLAR: Solar thermal version PURE: MAXI: DHW version HVAC systems version Cast-iron pump housing C: Composite pump housing B: Bronze pump housing A: Pump housing with air separator Noal diameter (DN) of suction and discharge ports [mm] Maximum head [dm] Port-to-port length [mm] ES2 Solar 1 6 / 13 14

15 PERFORMANCE CURVES AND PUMP SETTINGS 1 1 Q [US.gpm] 1 Q [IMS.gpm] H [m] H [ft] 6 max 2 1 max - max P Q [m 3 /h] Q [l/s] MATERIALS MODEL Pump housing Impeller Shaft Bearing Thrust bearing Rotor can ES2 SOLAR 6 Cast iron EN-GJL-2 with cataphoretic coating (KTL) Composite Ceramic Carbon Ceramic Composite DIMENSIONS, WEIGHTS H1 H B H2 B1 B2 L H3 G B3 MODEL THREAD DIMENSIONS [mm] WEIGHTS [Kg] G L B B1 B2 B3 H H1 H2 H3 Net Gross ES2 SOLAR 1-6/13 G ,8 29,4 14,4 49 1,67 1,87 ES2 SOLAR 2-6/13 G 1 ½ ,8 29,4 14,4 49 1,81 2,1 ES2 SOLAR 2-6/18 G 1 ½ ,8 29,4 14,4 49 1,96 2,16 SOLAR THERMAL 1

16 ENERGY SAVING ES2 SOLAR 7 A LED provides information about the operation status of the circulator Wide range of temperature from +2 C to +11 C, suitable for circulation in solar thermal systems The pump housing is cataphoresis treated (KTL) and resistant to corrosion APPLICATION Renewable energy solar thermal systems, biomass boilers and hot water heating systems of any kind. ENERGY EFFICIENCY INDEX EEI,21 - Part 2* MOTOR TECHNICAL DATA Power supply 1x23 V ( ±1%); Frequency: /6 Hz Electrical connection Pull resistant cable clamp PG11 Input power (P 1 ) Min. 3W, Max. 6W Input current (I 1 ) Min..3A, Max..44A Insulation class H Protection class IP44 Appliance class II PUMP TECHNICAL DATA Ambient temperature Allowed liquid temperature ** Temperature range at max. ambient temperature Operating pressure Minimum pressure on the intake opening from + C to +4 C from +2 C to +11 C of 3 C = +3 C to +11 C of 3 C = +3 C to +9 C of 4 C = +4 C to +7 C Max. 1. MPa - 1 bar.3 MPa (.3 bar) at C.1 MPa (1. bar) at 9 C.1 MPa (1. bar) at 11 C Maximum relative humidity 9% Sound pressure level < 43 db(a) Low Voltage directive (26/9/CE) Standard used: EN 62233, EN 633-1and EN EMC Directive (24/18/CE) Standard used: EN and EN , EN 14-1 and EN 14-2 Ecodesign Directive (29/12/CE) Standard used: EN and EN TYPE KEY * The benchmark for most efficient circulators is EEI,2. ** To avoid condensation in the motor and electronics the temperature of the pumped liquid must always be greater than the ambient temperature. Example Electronic circulator Standard version ADAPT: Version with activeadapt SOLAR: Solar thermal version PURE: MAXI: DHW version HVAC systems version Cast-iron pump housing C: Composite pump housing B: Bronze pump housing A: Pump housing with air separator Noal diameter (DN) of suction and discharge ports [mm] Maximum head [dm] Port-to-port length [mm] ES2 Solar 1 7 / 13 16

17 PERFORMANCE CURVES AND PUMP SETTINGS 1 1 Q [US.gpm] 1 Q [IMS.gpm] H [m] H [ft] 7 6 max 2 max - max P Q [m 3 /h] Q [l/s] MATERIALS MODEL Pump housing Impeller Shaft Bearing Thrust bearing Rotor can ES2 SOLAR 7 Cast iron EN-GJL-2 with cataphoretic coating (KTL) Composite Ceramic Carbon Ceramic Composite DIMENSIONS, WEIGHTS H1 H B H2 B1 B2 L H3 G B3 MODEL THREAD DIMENSIONS [mm] WEIGHTS [Kg] G L B B1 B2 B3 H H1 H2 H3 Net Gross ES2 SOLAR 1-7/13 G ,8 29,4 114,4 49 1,91 2,11 ES2 SOLAR 2-7/13 G 1 ½ ,8 29,4 114,4 49 2, 2,2 ES2 SOLAR 2-7/18 G 1 ½ ,8 29,4 114,4 49 2,2 2,4 SOLAR THERMAL 17

18 ENERGY SAVING ES2 PURE C 4 The adjustment is simple and intuitive: simply turn the regulator Very high degrees of efficiency due to permanent magnets motor Innovative pump housing realized in composite plastic suitable for drinking water: hygienic and safe APPLICATION Domestic hot water circulation, drinking water circulation systems and similar domestic and industrial circulation systems. This circulator is suitable for drinking water only. MOTOR TECHNICAL DATA Power supply 1x23 V ( ±1%); Frequency: /6 Hz Electrical connection Pull resistant cable clamp PG11 Input power (P 1 ) Min. 4.3W, Max. 4W Input current (I 1 ) Min..3A, Max..32A Insulation class H Protection class IP44 Appliance class II PUMP TECHNICAL DATA Ambient temperature Allowed liquid temperature * Temperature range at max. ambient temperature Operating pressure Minimum pressure on the intake opening from + C to +4 C from +2 C to +9 C of 3 C = +3 C to +9 C of 3 C = +3 C to +9 C of 4 C = +4 C to +7 C Max. 1. MPa - 1 bar.3 MPa (.3 bar) at C.1 MPa (1. bar) at 9 C Maximum relative humidity 9% Sound pressure level < 43 db(a) Low Voltage directive (26/9/CE) Standard used: EN 62233, EN and EN EMC Directive (24/18/CE) Standard used: EN and EN , EN 14-1 and EN 14-2 Hydraulic group certifications TIFQ (IT), KTW (DE), DVGW W27 (DE), ACS (FR), WRAS (GB) TYPE KEY * To avoid condensation in the motor and electronics the temperature of the pumped liquid must always be greater than the ambient temperature. Example Electronic circulator Standard version ADAPT: Version with activeadapt SOLAR: Solar thermal version PURE: MAXI: DHW version HVAC systems version Cast-iron pump housing C: Composite pump housing B: Bronze pump housing A: Pump housing with air separator Noal diameter (DN) of suction and discharge ports [mm] Maximum head [dm] Port-to-port length [mm] ES2 Pure C 1 4 / 13 18

19 PERFORMANCE CURVES AND PUMP SETTINGS 1 Q [US.gpm] Q [IMS.gpm] H [m] H [ft] 1 4 max - max Q [m 3 /h] Q [l/s] MATERIALS MODEL Pump housing Impeller Shaft Bearing Thrust bearing Rotor can ES2 PURE C 4 PA 6T/6I GF Composite Composite Ceramic Carbon Ceramic Composite DIMENSIONS, WEIGHTS H1 H H2 B1 B B2 L G MODEL THREAD DIMENSIONS [mm] WEIGHTS [Kg] G L B B1 B2 H H1 H2 Net Gross ES2 PURE C 1-4/13 G ¾ 13 9,6 47,8 47, ,47 1,67 ES2 PURE C 1-4/13 G ,6 47,8 47, ,47 1,67 DOMESTIC HOT WATER 19

20 GLOSSARY SAVINGS Up to 8% less than traditional pumps Automatic Rotor Unlocking Program TECHNOLOGY Best available technology - PM Motor Heating system ENVIRONMENT Environment protection Underfloor heating system INVERTER TECH Best performance with high flexibility Cooling system Solar thermal system High-efficiency electronic circulator Quick and easy installation Domestic hot water circulation system Venting detection

21 SALES PARTNER Germany Taconova GmbH Rudolf-Diesel-Straße 8 D Singen T F deutschland@taconova.com taconova.com Poland Taconova Polska Sp z.o.o ul. Wrocławska 21/8 PL Poznań, Polska T polska@taconova.com taconova.com Czech Republic & Slovakia Taconova Group Prodejní kancelář / Business Centrum Kostelecká 879/9 196 Praha-Čakovice T F cesko-slovensko@taconova.com taconova.com Austria Manfred Richter GmbH & CoKG IZ NÖ-Süd Strasse 16, Obj. 69/8 23 Wiener Neudorf T F info@richterkg.at richterkg.at Switzerland Taconova Group Neunbrunnenstrasse 4 CH-8 Zürich T F group@taconova.com taconova.com For more information about our global sales partners for all other Taconova products, go to taconova.com

22 HYDRONIC BALANCING A MUST FOR MODERN BUILDING SERVICES Taconova TacoSetters feature a sight glass with scale, enabling quick, accurate and variable flow rate control, as well as balanced heat distribution and improved energy efficiency. UNDER FLOOR HEATING TECHNOLOGY FOR PERFECT INTERACTION Comprehensive range of perfectly matching balancing valves, actuators, room thermostats and connection modules that can be combined in a variety of ways, as well as fully assembled manifolds for underfloor heating systems for optimum energy distribution and a high level of comfort. SYSTEM TECHNOLOGY INTELLIGENT STATIONS Smart and connection-ready domestic hot water stations, heat interface units, storage loading and solar loading stations state of the art technology for reliable operation, reduced maintenance and optimised energy costs. VALVES AND ACCESSORIES FOR OPTIMUM SAFETY A wide range of modern valves and accessories, including thermostatic mixing valves, venting valves, dirt separators and multifunctional valves and accessories, as well as sensors and measuring equipment for comfort, exemplary safety and energy efficiency. YOU WILL FIND THE LATEST NEWS, PRODUCT INFORMATION, ANIMATIONS, DATA SHEETS AND MUCH MORE ON TACONOVA.COM Taconova Group AG Neunbrunnenstrasse 4 CH-8 Zurich T F group@taconova.com taconova.com 1 3/218

HIGH EFFICIENCY CIRCULATORS

HIGH EFFICIENCY CIRCULATORS HIGH EFFICIENCY CIRCULATORS Heating, Cooling, Solar Thermal and Domestic Hot Water SAVINGS Up to 80% less than traditional pumps TECHNOLOGY Best available technology - PM Motor ENVIRONMENT Environment

More information

1 Declaration of conformity

1 Declaration of conformity ENERGY SAVING 1 Declaration of conformity We Taco Italia S.r.l. declare under our sole responsibility that the family of products ENERGY SAVING to which this declaration relates are in conformity with

More information

GRUNDFOS DATA BOOKLET UPS2. Circulator pumps. 50/60 Hz

GRUNDFOS DATA BOOKLET UPS2. Circulator pumps. 50/60 Hz GRUNDFOS DATA BOOKLET UPS2 Circulator pumps 50/60 Hz UPS2 Table of contents 1. Product introduction 3 Type key.................................................................................... 3 Performance

More information

TACOTHERM DUAL PIKO MODULAR AND HIGHLY FLEXIBLE HEAT INTERFACE UNITS

TACOTHERM DUAL PIKO MODULAR AND HIGHLY FLEXIBLE HEAT INTERFACE UNITS TACOTHERM DUAL PIKO MODULAR AND HIGHLY FLEXIBLE HEAT INTERFACE UNITS CUSTOMIZE YOUR INDIVIDUAL STATION The heat interface units in the TacoTherm Dual Piko range adapt perfectly to local conditions. Whether

More information

TACOTHERM DUAL DECENTRALISED DOMESTIC HOT WATER TECHNOLOGY

TACOTHERM DUAL DECENTRALISED DOMESTIC HOT WATER TECHNOLOGY TACOTHERM DUAL DECENTRALISED DOMESTIC HOT WATER TECHNOLOGY WHAT DOES TACONOVA STAND FOR? Taconova Group AG is a well-established Swiss company with over years of experience in providing intelligent building

More information

Circulation pumps. Wet rotor circulators and accessories. Heating Drinking water Solar Geothermy Condensate

Circulation pumps. Wet rotor circulators and accessories. Heating Drinking water Solar Geothermy Condensate Circulation pumps Wet rotor circulators and accessories eating Drinking water Solar Geothermy Condensate CATALOGUE alm produces highly-efficient heating circulation pumps alm has been successfully developing

More information

Pumps BAFA. Heating Drinking water Solar Geothermy Condensate. gefördert

Pumps BAFA. Heating Drinking water Solar Geothermy Condensate. gefördert Pumps eating Drinking water Solar Geothermy Condensate BAFA gefördert CATALOGUE The Company For more than years, ALM has developed and produced motors and pumps. In the beginning exclusively for well-known

More information

GRUNDFOS DATA BOOKLET. Grundfos COMFORT. Circulator pumps. 50/60 Hz

GRUNDFOS DATA BOOKLET. Grundfos COMFORT. Circulator pumps. 50/60 Hz GRUNDFOS DATA BOOKLET Circulator pumps 50/60 Hz 2 Product range 2. Product range UP(S) COMFORT, 50/60 Hz Pump type 24-hour timer Supplied with Dimensions Accessories Data sheet Thermostat Isolating valve

More information

made in ITALY high efficiency circulators CATALOGUE en greatperformance easyuse

made in ITALY high efficiency circulators CATALOGUE en greatperformance easyuse made in ITALY high efficiency circulators CATALOGUE en easyuse greatperformance Innovation and the environment unite Askoll circulators are the result of both the commitment to continuously improve product

More information

Circulation pumps. Wet rotor circulators and accessories Heating Drinking water Solar Geothermy Condensate

Circulation pumps. Wet rotor circulators and accessories Heating Drinking water Solar Geothermy Condensate Circulation pumps Wet rotor circulators and accessories eating Drinking water Solar Geothermy Condensate + CATALOGUE ALM produces highly-efficient heating circulation pumps ALM has been successfully developing

More information

Pumps. Heating Drinking water Solar Geothermy Condensate

Pumps. Heating Drinking water Solar Geothermy Condensate Pumps eating Drinking water Solar Geothermy Condensate + CATALOGUE The Company For more than years, ALM has developed and produced motors and pumps. In the beginning exclusively for well-known OEM customers,

More information

APPLICATIONS. For the accelerated circulation of hot water in heating circuits with duty point optimisation

APPLICATIONS. For the accelerated circulation of hot water in heating circuits with duty point optimisation OPERATING RANGE Flow rate of up to m /h Manometric head of up to m Max. operating pressure bar Min. intake pressure, bar at 9 C Water temperature range + at + C * EEI-Part, * for a ambient temperature

More information

magnetite separator New: Dirt and TACOVENT RANGE AIR, DIRT AND MAGNETITE SEPARATOR

magnetite separator New: Dirt and TACOVENT RANGE AIR, DIRT AND MAGNETITE SEPARATOR New: Dirt and magnetite separator TACOVENT RANGE AIR, DIRT AND MAGNETITE SEPARATOR AIR, GASES AND CONTAMINANTS IN HYDRONIC PLANT SYSTEMS The energy wasted as a result of trapped particles in flow systems

More information

Circulation pumps BAFA. Wet rotor circulators. gefördert. Heating Drinking water Solar Geothermy Condensate

Circulation pumps BAFA. Wet rotor circulators. gefördert. Heating Drinking water Solar Geothermy Condensate Circulation pumps Wet rotor circulators eating Drinking water Solar Geothermy Condensate BAFA gefördert CATALOGUE ALM produces highly-efficient heating circulation pumps ALM has been successfully developing

More information

Preconfigured heat interface unit with compact installation depth for preparation of domestic hot water and apartment heating.

Preconfigured heat interface unit with compact installation depth for preparation of domestic hot water and apartment heating. T T TACOTHERM DUAL PIKO HEAT INTERFACE UNIT ADVANTAGES Compact installation depth Large number of variants Preconfigured for simple installation On-demand, hygienic preparation of domestic hot water Demand-driven

More information

CALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB

CALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB Set point thermostatic regulating unit 8 series FM 65 00 CALEFFI 090/8 GB replaces dp 090/5 GB Function The thermostatic regulating unit is made to be used in radiant panel systems, in combination with

More information

PRIUX HOME D. High-efficiency double circulating pumps Heating Air conditioning 50 Hz OPERATING RANGE APPLICATIONS BENEFITS

PRIUX HOME D. High-efficiency double circulating pumps Heating Air conditioning 50 Hz OPERATING RANGE APPLICATIONS BENEFITS OPERATING RANGE Flow rate of up to 7 m /h* Manometric head of up to 8 mwc Max. operating pressure bar Min. suction pressure, bar at 9C Temperature range -C at 9C Max. ambient temperature +C EEI-Part Priux

More information

MORE DEMAND. than a pump. grundfos MAGNA3

MORE DEMAND. than a pump. grundfos MAGNA3 grundfos MAGNA3 DEMAND MORE than a pump Full range of intelligent, high-efficiency circulators for heating, cooling, ground source heat pump systems and domestic hot water applications More than a pump

More information

Circulation pumps. Wet rotor circulators and accessories. Heating Potable water Solar Geothermy Condensate

Circulation pumps. Wet rotor circulators and accessories. Heating Potable water Solar Geothermy Condensate Circulation pumps Wet rotor circulators and accessories eating Potable water Solar Geothermy Condensate CATALOGUE / alm produces highly-efficient heating circulation pumps alm has been successfully developing

More information

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW Stainless steel range of condensing boilers Outputs from 50kW to 660kW Designed to meet carbon reduction targets Lifetime service and support Totally dependable. page 1 www.pottertoncommercial.co.uk Contents

More information

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Reduced Installation time Precision regulation Minimal tooling required 100% tested prior to packaging High quality

More information

50/60 Hz. ecocirc BASIC Series WET ROTOR CIRCULATORS FOR HEATING, COOLING AND SANITARY SYSTEMS. ErP 2009/125/EC

50/60 Hz. ecocirc BASIC Series WET ROTOR CIRCULATORS FOR HEATING, COOLING AND SANITARY SYSTEMS. ErP 2009/125/EC / Hz ecocirc BASIC Series WET ROTOR CIRCULATORS FOR HEATING, COOLING AND SANITARY SYSTEMS ErP 9//EC Cod. 9 Rev. C Ed./ ecocirc BASIC SERIES INSTALLATION POSITIONS Lowara, ecocirc, Xylect are trademarks

More information

Lowara ecocirc and ecocirc PREMIUM

Lowara ecocirc and ecocirc PREMIUM Lowara and PREMIUM THE REVOLUTIONARY HIGH EFFICIENCY CIRCULATORS FOR DOMESTIC HEATING WITH THE SIMPLE AND SHAFTLESS SPHERICAL MOTOR DESIGN AND PATENTED ANTI-BLOCK TECHNOLOGY How can efficiency work even

More information

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support Aluminium range of condensing boilers Outputs from 30kW to 600kW Designed to meet carbon reduction targets Lifetime service and support Works every time. www.pottertoncommercial.co.uk Aluminium range of

More information

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control. product selection data Compact comfort module DHW management possibility Multi zone option control Easy installation Comfort module with two-zone kit Single-zone comfort module Comfort Module Range for

More information

MAGNA3 More than A pump

MAGNA3 More than A pump MAGNA3 More than A pump Full range of intelligent, high-efficiency circulators for heating, cooling, ground source heat pump systems and domestic hot water applications Features More than a pump If you

More information

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support Aluminium range of condensing boilers Outputs from 30kW to 600kW Designed to meet carbon reduction targets Lifetime service and support Works every time. www.pottertoncommercial.co.uk Aluminium range of

More information

MAGNA3 MAGNA3. The full Grundfos product range covers all building application areas:

MAGNA3 MAGNA3. The full Grundfos product range covers all building application areas: MAGNA3 We offer a complete range of MAGNA3 pumps with unrivalled efficiency, intelligent technology to match your every need and the well-known Grundfos reliability based on years of experience. MAGNA3

More information

Commercial, Residential & Institutional Pumps, Tanks, & Accessories

Commercial, Residential & Institutional Pumps, Tanks, & Accessories Taco International Commercial, Residential & Institutional Pumps, Tanks, & Accessories Taco Catalog # : 300-6.0 Supersedes: 300-3.5 9/11/06 Effective Date: 03/21/07 Printed in USA Pumps FI Frame Mounted

More information

MORE DEMAND THAN A PUMP GRUNDFOS MAGNA3

MORE DEMAND THAN A PUMP GRUNDFOS MAGNA3 GRUNDFOS MAGNA3 DEMAND MORE TAN A PUMP Full range of intelligent, high-efficiency circulators for heating, cooling, ground source heat pump systems and domestic hot water applications MORE TAN A PUMP IF

More information

SXS. CIRCULATING PUMPS FOR COLLECTIVE APPLICATIONS Domestic hot water Bronze housing 2 poles 50 Hz 230 V OPERATING RANGES APPLICATIONS BENEFITS

SXS. CIRCULATING PUMPS FOR COLLECTIVE APPLICATIONS Domestic hot water Bronze housing 2 poles 50 Hz 230 V OPERATING RANGES APPLICATIONS BENEFITS OPERATING RANGES Flow rates of up to m /h Manometric heads of up to m Max. operating pressure bar Max. ambient temperature + C Max. loop* temperature * + C Water hardness (TH) F DN ports DN at * à + C

More information

SL S.S.N.51D

SL S.S.N.51D GRUNDFOS DATA BOOKLET SL1.8..265.2.52S.S.N.51D Grundfos Pump 9814549 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/seslfam/9814549/sl1-8--265-2-52s-s-n-51d.html

More information

UP/UPS-B/UPN Hot Water Service Circulators

UP/UPS-B/UPN Hot Water Service Circulators UP/UPS-B/UPN Hot Water Service Circulators Visions & Values It is the Vision of the Company to achieve our Corporate Mission by providing quality and innovative products and services that give our customers

More information

Affordable efficiency!

Affordable efficiency! Lowara Ecocirc THE REVOLUTIONARY HIGHLY EFFICIENT CIRCULATORS FOR DOMESTIC HEATING WITH THE SIMPLE AND SHAFTLESS SPHERICAL MOTOR DESIGN AND PATENTED ANTI-BLOCK-TECHNOLOGY. Affordable efficiency! Approximately

More information

Grundfos is pleased to announce the sales release of many exciting new products.

Grundfos is pleased to announce the sales release of many exciting new products. GRUNDFOS BULLETIN Title: Sales Release Announcement Bulletin Number: DB-219-9-1 To: Grundfos Partners January 9, 219 Dear Partners, Grundfos is pleased to announce the sales release of many exciting new

More information

Lowara ecocirc and ecocirc PREMIUM THE NEW HIGHLY EFFICIENT CIRCULATORS WITH THE PATENTED ANTI-BLOCK-TECHNOLOGY

Lowara ecocirc and ecocirc PREMIUM THE NEW HIGHLY EFFICIENT CIRCULATORS WITH THE PATENTED ANTI-BLOCK-TECHNOLOGY NE W Lowara ecocirc and ecocirc PREMIUM THE NEW HIGHLY EFFICIENT CIRCULATORS WITH THE PATENTED ANTI-BLOCK-TECHNOLOGY Ecocirc_Premium_uk.indd 1 28/10/13 12.26 How can efficiency even w The simple spherical

More information

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient PRODUCT SELECTION DATA Easy and fast installation Compact, reliable and efficient Class A variable speed circulator available Air-Cooled Liquid Chillers 0RB 008-015 CARRIER participates in the ECP programme

More information

High-efficiency circulating pumps Heating Air conditioning 50 Hz

High-efficiency circulating pumps Heating Air conditioning 50 Hz OPERATING RANGE Flow rate of up to m /h Manometric head of up to 8 mwc Max. operating pressure bar Min. suction pressure, bar at 9 C Temperature range - C at 9 C Max. ambient temperature + C EEI-Part,

More information

IMMERSIBLE PUMPS FOR INDUSTRY

IMMERSIBLE PUMPS FOR INDUSTRY GRUNDFOS INDUSTRIAL SOLUTIONS Grundfos MTR, MTH, MTA, MTS pumps IMMERSIBLE PUMPS FOR INDUSTRY COMPACT TANK TOP SOLUTIONS FOR DEMANDING APPLICATIONS RENOWNED FOR THEIR RELIABILITY AND PRECISION MTA MTH

More information

Lowara ecocirc and ecocirc PREMIUM

Lowara ecocirc and ecocirc PREMIUM Lowara and PREMIUM THE REVOLUTIONARY HIGHLY EFFICIENT CIRCULATORS FOR DOMESTIC HEATING WITH THE SIMPLE AND SHAFTLESS SPHERICAL MOTOR DESIGN AND PATENTED ANTI-BLOCK TECHNOLOGY How can efficiency work The

More information

Horizontal Split Case Pumps Type U

Horizontal Split Case Pumps Type U Horizontal Split Case Pumps Type U 7.1 7.2 Stage U Type Pumps Features: Axially Split Case Design Range from 20M 3 /Hr to 600M 3 /Hr Two Stage Pump Single Suction Twin Volute Casing Design Closed type

More information

SL EX.4.51D

SL EX.4.51D GRUNDFOS DATA BOOKLET SL1.1.1.75.EX.4.51D Grundfos pump 962669 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/sl1/962669/sl1-1-1-75-ex-4-51d-c.html

More information

COMPASS HIGH-EFFICIENCY WET-ROTOR CIRCULATORS

COMPASS HIGH-EFFICIENCY WET-ROTOR CIRCULATORS COMPASS HIGH-EFFICIENCY WET-ROTOR CIRCULATORS INSTALLATION AND OPERATING INSTRUCTIONS File No: 10.895 Date: march 8, 014 Supersedes: 10.895 Date: december 10, 013 1.0 Symbols used in this document 1.0

More information

1592P01. for liquids in piping DN

1592P01. for liquids in piping DN 1 594 1592P01 Flow switch for liquids in piping DN 20 200. QVE1901 Contact load / switching capacity: max. AC 230 V, 1 A, 26 VA max. DC 48 V, 1 A, 20 W Nominal pressure PN25 Manual setting of contact type

More information

OCHSNER hot water heat pumps NATURAL HOT WATER

OCHSNER hot water heat pumps NATURAL HOT WATER OCHSNER hot water heat pumps NATURAL HOT WATER OCHSNER hot water heat pumps HOT WATER HEATING MORE EFFICIENT THAN EVER The Europa Series heat pumps are the ideal supplement to any heating system for providing

More information

Calio-Therm S NC/NCV Type Series Booklet

Calio-Therm S NC/NCV Type Series Booklet High-efficiency Drinking Water Pump Calio-Therm S NC/NCV Type Series Booklet Legal information/copyright Type Series Booklet Calio-Therm S NC/NCV All rights reserved. The contents provided herein must

More information

Blockpumps. Vogel Series LSB. Lenntech. Tel Fax

Blockpumps. Vogel Series LSB. Lenntech. Tel Fax Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Blockpumps Vogel Series LSB WITH HYDRAULICS ACCORDING TO ISO 2858 Technical Data Performance: m Capacity up to 450m

More information

ecocirc XL HIGH EFFICIENCY LARGE WET ROTOR PUMP FOR HEATING, COOLING AND POTABLE WATER SYSTEMS A-162C

ecocirc XL HIGH EFFICIENCY LARGE WET ROTOR PUMP FOR HEATING, COOLING AND POTABLE WATER SYSTEMS A-162C ecocirc XL HIGH EFFICIENCY LARGE WET ROTOR PUMP FOR HEATING, COOLING AND POTABLE WATER SYSTEMS A-162C Exactly what you need in a circulator As the industry leader with more HVAC and plumbing installations

More information

Pumps Mixers Aeration Controls Services SCANPUMP SPLIT CASING PUMP Z22.

Pumps Mixers Aeration Controls Services SCANPUMP SPLIT CASING PUMP Z22. Pumps Mixers Aeration Controls Services SCANPUMP SPLIT CASING PUMP Z22. SERIES Z22 - WHEN GOOD IS NOT ENOUGH. Since we delivered our first process pumps back in the 1870 s, our goal has been to optimize

More information

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016 SECTION 23 21 23 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General Conditions and Division 01 Specification Sections, apply to this Section.

More information

GRUNDFOS DATA BOOKLET MAGNA3. Circulator pumps 60 Hz

GRUNDFOS DATA BOOKLET MAGNA3. Circulator pumps 60 Hz GRUNDFOS DATA BOOKLET Circulator pumps 60 z Table of contents 1. Product introduction 3 Features and benefits 3 Applications 3 2. Performance range 4 4 D single-head operation 5 D twin-head operation 6

More information

Wilo IL Vertical Split-Coupled Inline Pumps

Wilo IL Vertical Split-Coupled Inline Pumps Wilo IL Vertical Split-Coupled Inline Pumps Vertical Inline Split-Coupled, Single Stage Pumps March, 2013 Marcos D. Roimicher, Product Manager BS Market Segment, Product Management Department 120-08-002-0313

More information

HEAT INTERFACE UNITS (Sanitary Hot Water Only)

HEAT INTERFACE UNITS (Sanitary Hot Water Only) HEAT INTERFACE UNITS (Sanitary Hot Water Only) T-FAST i20 (Sanitary Hot Water Only) 20 The T-Fast i20 is an instantaneous domestic hot water production module that produces a flow rate of 20L per/min at

More information

LMF Rotary Screw Air Compressors kW LX Range

LMF Rotary Screw Air Compressors kW LX Range LMF Rotary Screw Air Compressors 5.5-400kW LX Range OUR SOLUTIONS ARE YOUR BENIFITS Optimized package design Company Profile LMF is an Austrian manufacturer of reciprocating and rotary screw air and gas

More information

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw Superior A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler Outputs 120, 160, 200, 240, 280 kw 1 The Superior is a, pre-assembled floor standing, gas fired high efficiency

More information

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet CBU144 Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717 Product specification sheet Version The Compact Booster Unit consists of the following modules, that

More information

Midea VFD Centrifugal Chiller Technology

Midea VFD Centrifugal Chiller Technology Midea VFD Centrifugal Chiller Technology Content Why VFD VFD centrifugal chiller technology Solution 2 HVAC major issues Energy conservation Global warming reduction 3 Why VFD No Compressor A/C Lower GWP

More information

Taco 00 Series Cartridge Circulators

Taco 00 Series Cartridge Circulators Water Circulation Pumps & Circulators Taco 00 Series Cartridge Circulators For over 70 years, Taco has led the industry with the highest quality circulators you can buy. Designed for a wide range of residential

More information

SCP Heating and Circulation Pumps

SCP Heating and Circulation Pumps SCP Heating and Circulation Pumps Approvals CERTIFICATE IQNet and SQS hereby certify that the organisation Swiss Pump Company AG 3645 Thun-Gwatt Switzerland Certi ed area Whole company Field of activity

More information

HTM Circulation Pumps acc. to DIN EN 733 Type NKX

HTM Circulation Pumps acc. to DIN EN 733 Type NKX HTM Circulation Pumps acc. to DIN EN 733 Type NKX General The new NKX pump line replaces our former heat transfer oil circulation pump type NKL s. The outer dimensions of both pump types are identical

More information

PRODUCT EVOLUTION. A new PATENTED milestone of DAB evolution.

PRODUCT EVOLUTION. A new PATENTED milestone of DAB evolution. ELECTRONIC Water Pressure System We conceived e.sybox according to our idea of ergonomic technology* and we have developed it enclosing and expressing all the DAB technological know-how based on 37 years

More information

KEMPER ThermoSystem. For further information on KTS use the QR code!

KEMPER ThermoSystem. For further information on KTS use the QR code! KEMPER ThermoSystem Heating water hygienically and energy-efficiently with patented cascade rotation for automated operating change among all heating modules For further information on KTS use the QR code!

More information

SECTION PUMPS. 6. Section Steam and Condensate Piping and Specialties.

SECTION PUMPS. 6. Section Steam and Condensate Piping and Specialties. SECTION 15540 PUMPS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Base Mounted Pumps. 2. Horizontal Split Case Pumps. 3. In line Pumps. 4. Steam Condensate Return Pumps. B. Related Sections: 1. Section

More information

Circulation Pump Optima

Circulation Pump Optima ECO DESIGN Circulation Pump Optima The First&Only According to Directives AT THE HEART OF THE SYSTEM ErP READY LOW ENERGY CONSUMPTION SAVE the NATURE Over years of Alarko experience in Circulation Pumps...

More information

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production SATK0 - SATK0 series ACCREDITED ISO 900 FM 009/ GB replaces dp 009/ GB Function The latest generation of Heat Interface

More information

CASSETTE UNIT. Comfort Circle

CASSETTE UNIT. Comfort Circle CASSETTE UNIT Comfort Circle Comfort Circle cassette unit All-round comfort With today's energy prices, building owners are increasingly aware of the need for an efficient climate system to heat or cool

More information

Water-cooled chillers with High Speed Centrifugal Compressors

Water-cooled chillers with High Speed Centrifugal Compressors Water-cooled chillers with High Speed Centrifugal Compressors Refrigerant R134a 190-760 (395 to 2660 kw) Refrigerant R1234ze 135 G - 505 G (310 to 1820 kw) Table of Contents Introduction...3 Features and

More information

Geolo THE GROUND SOURCE HEAT PUMP PLUSES

Geolo THE GROUND SOURCE HEAT PUMP PLUSES Geolo THE GROUND SOURCE HEAT PUMP PLUSES RENEWABLE TECHNOLOGIES Geolo is able to exploit the Energy present in the water and underground thanks to the geothermal exchangers. Soil and water absorb the solar

More information

WALL-HUNG HIGH EFFICIENCY GAS BOILERS

WALL-HUNG HIGH EFFICIENCY GAS BOILERS Heating Hot water Renewables GAS BOILERS E-COMBIevo E-SYSTEMevo CLAS HEevo CLAS HEevo system CLAS HE R WALL-HUNG HIGH EFFICIENCY GAS BOILERS Ariston a tradition that evolves For many years, we have entered

More information

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function Thermostatic regulating unit for heating systems 66 series ACCREDITED ISO 9 FM 6 8/7 GB replaces dp 8/ GB Function The thermostatic regulating unit performs the function of keeping the flow temperature

More information

Balancing & Control. Frese PV Compact. Differential Pressure Control Valve

Balancing & Control. Frese PV Compact. Differential Pressure Control Valve Balancing & Control Frese PV Compact Differential Pressure Control Valve Balancing & Control Frese PV Compact Differential Pressure Control Frese Innovative solutions from Frese balance global HVAC systems

More information

EXPLORER HEAT PUMP WATER HEATER. A+ in READY Smart heat pump

EXPLORER HEAT PUMP WATER HEATER. A+ in READY Smart heat pump HEAT PUMP WATER HEATER EXPLORER 7% energy savings * Wide temperature range of use (- to + C) ACI hybrid anti-corrosion protection Smart energy consumption control Remote piloting with Cozytouch technology

More information

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL INLINE CENTRIFUGAL FAN OPERATION MANUAL www.blaubergventilatoren.de CONTENT 3 Introduction 3 General 3 Safety rules 3 Transport and storage requirements 3 Manufacturer's warranty 4 Fan design 4 Delivery

More information

High temperature air-to-water heat pumps

High temperature air-to-water heat pumps Designed to replace conventional boilers and produce domestic hot water 4 High temperature hot water (+65 C) 4 Winter operation (-20 C) 4 High energy efficiency (CP) 4 Compact and quiet 4 Scroll compressors

More information

Technical Product Guide

Technical Product Guide FMU - Floor Mixing Unit Boxed set pre-assembled for immediate installation: The FMU Floor Mixing Unit integrates both temperature and flow management, making the single piece unit very easy to install,

More information

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation Air-Cooled Liquid Chillers www.eurovent-certification.com www.certiflash.com Quality Management Systems 0RB 008-05 Nominal cooling capacity 8- The new generation of Aquasnap liquid chillers was designed

More information

grundfos commercial building Grundfos Plumbing Solutions

grundfos commercial building Grundfos Plumbing Solutions grundfos commercial building Grundfos Plumbing Solutions wastewater submersible pumps Common Uses: Sump water ejection, wastewater ejection with high content of fibers and stormwater ejection. sump water

More information

Heating with wood chips & pellets

Heating with wood chips & pellets Heating with wood chips & pellets 20-60 kw 80-499 kw Competence is our success HERZ FACTS: 22 companies Group headquarters in Austria Research & development in Austria Austrian owned 1,600 employees in

More information

OEM Asynchronous Circulation Pumps

OEM Asynchronous Circulation Pumps Pioneering for You Catalogue Building Services September 7 OEM Asynchronous Circulation Pumps Glandless Pumps The international group WILO SE, which started as an historic family-run business with decades

More information

Lifting Plants Product Overview

Lifting Plants Product Overview Wilo-DrainLift Con Duty chart (-pole, 5 Hz) 5 Wilo-DrainLift Con Lifting Plants Product Overview Wilo-DrainLift Lifting Plants Condensate lifting plants Removal of condensate, can be used in Condensing

More information

GRUNDFOS PLUMBING & HVAC PRODUCTS

GRUNDFOS PLUMBING & HVAC PRODUCTS GRUNDFOS PLUMBING & HVAC PRODUCTS SERIES UP CIRCULATORS GRUNDFOS CIRCULATORS FOR HEATING AND HOT WATER RECIRCULATION Quiet, maintenance-free performance Stainless steel construction, corrosion resistant

More information

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features Comfort Module Range for Monobloc Heat Pumps Quality Management Systems Comfort module with two-zone kit Single-zone comfort module 8HMA Nominal heating capacity 4- kw Nominal cooling capacity 4- kw The

More information

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers. SECTION 22 10 00 PLUMBING PIPING AND PUMPS PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.

More information

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services TA-COMFORT-S Prefabricated units Heating interface unit for surface heating and hot water services IMI TA / Control valves / TA-COMFORT-S TA-COMFORT-S All in one design with STAP differential pressure

More information

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI Hydraulic Institute Standards. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Screw Compressors ESM Fixed Speed & VS Variable Speed

Screw Compressors ESM Fixed Speed & VS Variable Speed Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed Rely on GD to provide the perfect fit The perfect fit to maximise productivity The growing industrial demand for compressed air requires

More information

Domestic Pump Series VCMD TM Combination Vacuum & Boiler Feed Unit

Domestic Pump Series VCMD TM Combination Vacuum & Boiler Feed Unit Custom engineered units to maintain optimum boiler levels and system vacuum requirements Four styles to choose from to minimize floor space requirements Multi-jet vacuum pumps for quiet, dependable and

More information

HEAT PUMPS EN - flyer 10/p/2017 Made in Poland

HEAT PUMPS EN - flyer 10/p/2017 Made in Poland HEAT PUMPS EN - flyer 0/p/07 Made in Poland www.galmet.eu A + Spectra 60 AIR SOURCE HEAT PUMP WATER HEATER T E C H N O L O G I A FOR DHW - spectra AND spectra smart Spectra Smart heat pumps Convenient

More information

heat interface units A BOILER WITHOUT A FLAME

heat interface units A BOILER WITHOUT A FLAME A BOILER WITHOUT A FLAME heat interface units Communal Heat Networks A central boiler house will generate heat which is distributed through a network of pipe to each home or apartment in the building.

More information

TACOTHERM FRESH PETA (C/CL)

TACOTHERM FRESH PETA (C/CL) ACOHERM FRESH PEA (C/CL) FRESH HO WAER SAION WIH HIGH-EFFICIENCY PUMPS Fresh hot water station for hygienically heating drinking water in accordance with the continuous flow principle with and without

More information

EFFICIENCY RELIABILITY

EFFICIENCY RELIABILITY GRUNDFOS CIRCULATOR RANGE 2013/14 EFFICIENCY RELIABILITY SUPPORT INNOVATION DEMAND MORE FROM A CIRCULATOR Grundfos Pumps are a global manufacturer with an enviable reputation for supplying a wide range

More information

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59 SOUND-INSULATED FAN OPERATION MANUAL _v.1(2)-en.indd 1 10.08.2015 15:20:59 CONTENT Introduction 3 General 3 Safety rules 3 Transport and storage requirements 3 Manufacturer's warranty 3 Fan design 4 Delivery

More information

GRUNDFOS PRODUCT GUIDE MAGNA. UPE Series 2000 circulator pumps

GRUNDFOS PRODUCT GUIDE MAGNA. UPE Series 2000 circulator pumps GRUNDFOS PRODUCT GUIDE UPE Series 2000 circulator pumps Contents Mission Product data Features and benefits Applications 5 eating systems 5 Pumped liquids 5 Type key 6 Performance range, 6 Product range

More information

COMMISSION REGULATION (EU)

COMMISSION REGULATION (EU) L 180/4 Official Journal of the European Union 12.7.2012 COMMISSION REGULATION (EU) No 622/2012 of 11 July 2012 amending Regulation (EC) No 641/2009 with regard to ecodesign requirements for glandless

More information

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus. 24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers Enerwa / EnerwaPlus www.warmhaus.com Condensing-ErP Premix System Boilers 24/31-28/35-33/40 kw Warmhaus wall-hung gas combi boilers

More information

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems.

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems. Issued 2006/08/01 Section 15131 Pumps Hydronic Systems Page 1 of 6 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal.3 Section 01780

More information

Simply renewable A ++ A +++ ROTEX air-to-water heat pump

Simply renewable A ++ A +++ ROTEX air-to-water heat pump Simply renewable The HPSU monobloc air-to-water heat pump for external installation offers comfortable heat in winter and gentle cooling in summer. System efficiency with Solar*: XL A ++ A +++ * ROTEX

More information

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Design and Construction Standards SECTION PLUMBING EQUIPMENT SECTION 15450 PLUMBING EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES: A. Water heaters. B. Packaged water heating systems. C. Water storage tanks. D. Water softeners. E. Pumps. F. Circulators. 1.2 REFERENCES

More information

ecocirc vario Efficiency is affordable! The revolutionary heating circulator Efficiency at low price:

ecocirc vario Efficiency is affordable! The revolutionary heating circulator Efficiency at low price: Efficiency is affordable! The revolutionary heating circulator ecocirc vario Ecocirc E4vario Ecocirc E6vario Efficiency at low price: The revolutionary ecocirc vario. With efficient electronically commutated

More information

Rotary Screw Compressors. ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar.

Rotary Screw Compressors. ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar. Rotary Screw Compressors ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar www.kaeser.com ASK series ASK Maximum performance Discerning users expect

More information