1 OPERATING RANGE Flow rate of up to 7 m /h* Manometric head of up to 8 mwc Max. operating pressure bar Min. suction pressure, bar at 9C Temperature range -C at 9C Max. ambient temperature +C EEI-Part Priux home D. Priux home D 8. * pumps running in parallel The reference criterion for the most efficient circulating pumps is EEI, PRIUX HOME D High-efficiency double circulating pumps Heating Air conditioning Hz 7, Priux home D 8m Priux home D m APPLICATIONS For the accelerated circulation of hot water and iced water in the heating and air-conditioning circuits of single-family houses and small residential buildings respectively. New and old systems (renovation extension) Installations with and without thermostatically controlled valves Installations with radiators and underfloor heating systems Thermosiphon-type installations Qm /h, 7 BENEFITS Interchangeable with the CXL (Priux home D -) and DXM - (Priux home D 8-) Versatility: operation in alternating or parallel mode Simplified settings Easy replacement Installation and maintenance Energy savings Noise control Salmson connector N.T. N o -/ENG - Ed./-

2 DESIGN Hydraulic part - Double housing with threaded ports for direct fitting onto pipework. M o t o r - Single-phase, glandless, shaft bearings lubricated by the pumped fluid. - Synchronous motor with ECM (Electronically Commuted Motor) technology, equipped with a permanent magnet rotor. The magnetic field rotating around the stator is created by the electronic commutation of the coils. Protection class : IP XD Max. temperature of the conveyed fluid: TF 9 EMC compliance: BENEFITS Energy savings - Conforms to the European Directive: ErP and ErP (Priux home D -). - Energy savings of up to 9% compared to old-generation circulating pumps. - Minimum consumption: watts. - Display of current consumption. Noise control - Elimination of whistling and hydraulic noises thanks to electronic speed variation. Interchangeability - Two sizes of motor: m and 8 m - One type of port-to-port distance: 8 mm. - Type of connection:. Simplified settings - Just one setting dial. -LED display of the manometric head. -Choice of regulation mode according to the installation. Easy replacement - Markings for selecting the manometric head. Installation and maintenance - Requires less space. - Salmson connector: no tools required - Automatic degumming. - Versatility: operation in alternating/backup mode; a control box (not supplied) must be installed for automatic changeover. operation of both pumps in parallel, for savings on purchase and in operation. IDENTIFICATION Priux home D - / 8 High-efficiency Pump Electronic switching, permanent magnet motor Residential application Double Automatic degumming Activation of venting function min cycle to protect the system. HMT at m /h DN (nominal diameter) of ports Port-to-port distance of pump housing Just one setting dial Markers showing equivalence with the old -speed circulating pumps. Easy replacement. BASIC CONSTRUCTION Main parts Material Pump housing Cast iron Impeller Composite material Shaft, jacket and air gap Stainless steel Suction ring Stainless steel Shaft bearings Graphite Gasket Ethylene-propylene LED display On installation, accurate setting of the manometric head in increments of. m. Then display of current electric consumption to inform the use Salmson connector Tool-free connection. Separation of electrical and hydraulic connections for greater safety. Selection of setting mode pv (variable pressure) for systems with radiators. Only in alternating operation. pc (constant pressure) for systems with underfloor heating. In alternating or parallel operation.

3 SETTINGS Setting the Manometric Head Turning the white dial shows the manometric head in m on the LED display. For easier settings, the white dial may be set to the symbols I, II or III on the Δpc scale, which are marker points showing equivalence with the old -speed circulating pumps. Electricity consumption In operating mode, the current power consumption is displayed in W. Factory setting: ½ manometric head - Δpv. Regulation function: With this regulation mode, the differential pressure (manometric head) can be reduced electronically in the event of a reduction in the flow rate, according to the predefined differential pressure setpoint value. Recommended regulation mode for heating systems with thermostatically controlled valves Principle: If the pump is operating in alternating/backup mode, the preselected type of regulation and the manometric head setpoint value must be identical. With this regulation mode, the differential pressure of the circulating pump is kept at a constant level electronically, regardless of the flow rate, according to the predefined pressure setpoint value. Recommended regulation mode for installations with an underfloor heating system and for Thermosiphon-type installations. If both pumps are running in parallel mode at the same time, they MUST be set to Δp-c mode and the manometric head selected must be identical. Venting function: Primary purpose: When first started up, this function allows for the venting of air bubbles contained within the Priux home rotor chamber. Secondary purpose: This function also supports the venting of the heating system. As it operates, air bubbles trapped within the system are released and then conveyed to the highest point of the system (deaerator). The "venting" function lasts for minutes. After these minutes, the manometric head must be reset, otherwise the circulating pump will return to the factory setting.

4 HYDRAULIC PERFORMANCE Operation in alternating mode,,8, m/s,,8, m/s Priux home D - ~ V - Rp ¼ Priux home D - ~ V - Rp ¼ p-c p-v P W,,8 Ql/s P W,,8 Ql/s m m m m m m m m Operation in parallel mode,,8,,, m/s Priux home D - ~ V - Rp ¼ + p-c P W,,8, Ql/s m m m m P Priux home -

5 HYDRAULIC PERFORMANCE Operation in alternating mode,,, m/s,,, m/s 8 Priux home D 8- ~ V - Rp ¼ 8 8 Priux home D 8- ~ V - Rp ¼ 8 Δp-c Δp-v,,8, Ql/s P W 7m m m m m m,,8, Q/l/s P W 7m m m m m m Operation in parallel mode,,,,, m/s 8 Priux home D 8- ~ V - Rp ¼ + 8 Δp-c,,8,,, Ql/s P W 8 7m m m m m P Priux home 8-

6 PRIUX HOME D INSTALLATION POSITIONS ELECTRICAL CONNECTIONS Quick electrical connections requiring no tools

7 PRIUX HOME D ELECTRICAL AND DIMENSIONAL SPECIFICATIONS G = b=9 b=79 b=79 b= b= PLAQUE D'IDENTITE NAMEPLATE b= L= b= 9 ± AAAA b=8,7 7, L=8 ±, 7, l=, a=,7 l l Ø,8 Référence Order reference commande P (W) Min Max W W W 7W Priux home D - / 8 mm Priux home D 8- / 8 mm Moteur Motor I(A) Min Max,,,, Vitesse Speed (tr/min) (rpm) Min Max L 8 8 ACCESSORIES Référence Order reference commande Priux home D - / 8 mm L 7 Pompe Pump L L 7 ØD " " Weight Masse (kg),, SPECIFICITIES a) Electrical - V - Hz single-phase (Hz). - Not essential for the motor to be protected by a circuit breaker. Threaded tubesur connection Raccordement tube fileté /" /" " "/ " RED RU RU 9 Shut-off ball valve RU - Ref.: 7 Pipe union b) Installation - Motor axis always horizontal. - Connection to system by pipe unions. c) Packaging - Supplied with connector and gaskets, without pipe unions. d) Maintenance - Standard exchange of the appliance. - Spare motor head available as an accessory. ØG / - Adapter rings Ref. 8 m cable with side connector (in sets of ) Ref.: 8 7

High-efficiency circulating pumps Heating Air conditioning 50 Hz

High-efficiency circulating pumps Heating Air conditioning 50 Hz OPERATING RANGE Flow rate of up to m /h Manometric head of up to 8 mwc Max. operating pressure bar Min. suction pressure, bar at 9 C Temperature range - C at 9 C Max. ambient temperature + C EEI-Part,

More information

APPLICATIONS. For the accelerated circulation of hot water in heating circuits with duty point optimisation

APPLICATIONS. For the accelerated circulation of hot water in heating circuits with duty point optimisation OPERATING RANGE Flow rate of up to m /h Manometric head of up to m Max. operating pressure bar Min. intake pressure, bar at 9 C Water temperature range + at + C * EEI-Part, * for a ambient temperature

More information

SXS. CIRCULATING PUMPS FOR COLLECTIVE APPLICATIONS Domestic hot water Bronze housing 2 poles 50 Hz 230 V OPERATING RANGES APPLICATIONS BENEFITS

SXS. CIRCULATING PUMPS FOR COLLECTIVE APPLICATIONS Domestic hot water Bronze housing 2 poles 50 Hz 230 V OPERATING RANGES APPLICATIONS BENEFITS OPERATING RANGES Flow rates of up to m /h Manometric heads of up to m Max. operating pressure bar Max. ambient temperature + C Max. loop* temperature * + C Water hardness (TH) F DN ports DN at * à + C

More information

SUBMERSIBLE PUMPS For water with particulate matter 2 pole - 50 Hz 2 ranges : SS 304 & SS 316 L

SUBMERSIBLE PUMPS For water with particulate matter 2 pole - 50 Hz 2 ranges : SS 304 & SS 316 L operating limits Flow up to: m /h Head up to: m w.g. Liquid temperature range: + to 5 C* Specific gravity of liquid:.5 max. ph of liquid: - Max. immersion depth: m Free passage: Ø mm ND of discharge port:

More information

Pumps. Heating Drinking water Solar Geothermy Condensate

Pumps. Heating Drinking water Solar Geothermy Condensate Pumps eating Drinking water Solar Geothermy Condensate + CATALOGUE The Company For more than years, ALM has developed and produced motors and pumps. In the beginning exclusively for well-known OEM customers,

More information

Circulation pumps. Wet rotor circulators and accessories Heating Drinking water Solar Geothermy Condensate

Circulation pumps. Wet rotor circulators and accessories Heating Drinking water Solar Geothermy Condensate Circulation pumps Wet rotor circulators and accessories eating Drinking water Solar Geothermy Condensate + CATALOGUE ALM produces highly-efficient heating circulation pumps ALM has been successfully developing

More information

GRUNDFOS DATA BOOKLET UPS2. Circulator pumps. 50/60 Hz

GRUNDFOS DATA BOOKLET UPS2. Circulator pumps. 50/60 Hz GRUNDFOS DATA BOOKLET UPS2 Circulator pumps 50/60 Hz UPS2 Table of contents 1. Product introduction 3 Type key.................................................................................... 3 Performance

More information

Pumps BAFA. Heating Drinking water Solar Geothermy Condensate. gefördert

Pumps BAFA. Heating Drinking water Solar Geothermy Condensate. gefördert Pumps eating Drinking water Solar Geothermy Condensate BAFA gefördert CATALOGUE The Company For more than years, ALM has developed and produced motors and pumps. In the beginning exclusively for well-known

More information

TP /4-A-F-A-BQQE 400D 50HZ

TP /4-A-F-A-BQQE 400D 50HZ GRUNDFOS DATA BOOKLET TP 15-7/-A-F-A-BQQE D 5HZ Grundfos pump 989838 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tp/989838/tp-15-7--a-f-a-bqqe.html

More information

Circulation Pump Optima

Circulation Pump Optima ECO DESIGN Circulation Pump Optima The First&Only According to Directives AT THE HEART OF THE SYSTEM ErP READY LOW ENERGY CONSUMPTION SAVE the NATURE Over years of Alarko experience in Circulation Pumps...

More information

ecocirc vario Efficiency is affordable! The revolutionary heating circulator Efficiency at low price:

ecocirc vario Efficiency is affordable! The revolutionary heating circulator Efficiency at low price: Efficiency is affordable! The revolutionary heating circulator ecocirc vario Ecocirc E4vario Ecocirc E6vario Efficiency at low price: The revolutionary ecocirc vario. With efficient electronically commutated

More information

GRUNDFOS DATA BOOKLET. Grundfos COMFORT. Circulator pumps. 50/60 Hz

GRUNDFOS DATA BOOKLET. Grundfos COMFORT. Circulator pumps. 50/60 Hz GRUNDFOS DATA BOOKLET Circulator pumps 50/60 Hz 2 Product range 2. Product range UP(S) COMFORT, 50/60 Hz Pump type 24-hour timer Supplied with Dimensions Accessories Data sheet Thermostat Isolating valve

More information

Circulation pumps BAFA. Wet rotor circulators. gefördert. Heating Drinking water Solar Geothermy Condensate

Circulation pumps BAFA. Wet rotor circulators. gefördert. Heating Drinking water Solar Geothermy Condensate Circulation pumps Wet rotor circulators eating Drinking water Solar Geothermy Condensate BAFA gefördert CATALOGUE ALM produces highly-efficient heating circulation pumps ALM has been successfully developing

More information

Circulation pumps. Wet rotor circulators and accessories. Heating Drinking water Solar Geothermy Condensate

Circulation pumps. Wet rotor circulators and accessories. Heating Drinking water Solar Geothermy Condensate Circulation pumps Wet rotor circulators and accessories eating Drinking water Solar Geothermy Condensate CATALOGUE alm produces highly-efficient heating circulation pumps alm has been successfully developing

More information

COMPASS HIGH-EFFICIENCY WET-ROTOR CIRCULATORS

COMPASS HIGH-EFFICIENCY WET-ROTOR CIRCULATORS COMPASS HIGH-EFFICIENCY WET-ROTOR CIRCULATORS INSTALLATION AND OPERATING INSTRUCTIONS File No: 10.895 Date: march 8, 014 Supersedes: 10.895 Date: december 10, 013 1.0 Symbols used in this document 1.0

More information

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Reduced Installation time Precision regulation Minimal tooling required 100% tested prior to packaging High quality

More information

Lowara ecocirc and ecocirc PREMIUM

Lowara ecocirc and ecocirc PREMIUM Lowara and PREMIUM THE REVOLUTIONARY HIGH EFFICIENCY CIRCULATORS FOR DOMESTIC HEATING WITH THE SIMPLE AND SHAFTLESS SPHERICAL MOTOR DESIGN AND PATENTED ANTI-BLOCK TECHNOLOGY How can efficiency work even

More information

Lowara ecocirc and ecocirc PREMIUM

Lowara ecocirc and ecocirc PREMIUM Lowara and PREMIUM THE REVOLUTIONARY HIGHLY EFFICIENT CIRCULATORS FOR DOMESTIC HEATING WITH THE SIMPLE AND SHAFTLESS SPHERICAL MOTOR DESIGN AND PATENTED ANTI-BLOCK TECHNOLOGY How can efficiency work The

More information

HIGH EFFICIENCY CIRCULATORS

HIGH EFFICIENCY CIRCULATORS HIGH EFFICIENCY CIRCULATORS Heating, Cooling, Solar Thermal and Domestic Hot Water SAVINGS Up to 80% less than traditional pumps TECHNOLOGY Best available technology - PM Motor ENVIRONMENT Environment

More information

Heating, air-conditioning, cooling

Heating, air-conditioning, cooling Series description Design landless circulation pup with threaded connection, blockingcurrent proof EC otor and integrated electronic power control. Application All hot water heating systes, air-conditioning

More information

Wilo Stratos Variable Speed Inline Pumps. Engineering Specification

Wilo Stratos Variable Speed Inline Pumps. Engineering Specification Wilo Stratos Variable Speed Inline Pumps Engineering Specification PART 1 - GENERAL 1.1 WORKED INCLUDED A. Furnish and install circulating pumps consistent with the hydronic system s performance, requirements

More information

CR A-F-A-E-HQQE 3x400/ HZ

CR A-F-A-E-HQQE 3x400/ HZ GRUNDFOS DATA BOOKLET CR45-12-2 A-F-A-E-HQQE 3x4/69 5 HZ Grundfos Pump 96122818 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96122818/cr-45-12-2-a-f-a-e-hqqe.html

More information

CR64-1 A-F-A-E-HQQE 3x400D 50 HZ

CR64-1 A-F-A-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CR64-1 A-F-A-E-HQQE 3x4D 5 HZ Grundfos Pump 96123527 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96123527/cr-64-1-a-f-a-e-hqqe.html

More information

CR A-F-A-E-HQQE 3x400D 50 HZ

CR A-F-A-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CR64-2-2 A-F-A-E-HQQE 3x4D 5 HZ Grundfos Pump 96123528 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96123528/cr-64-2-2-a-f-a-e-hqqe.html

More information

CR10-16 A-FJ-A-E-HQQE 3x400D 50 HZ

CR10-16 A-FJ-A-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CR1-16 A-FJ-A-E-HQQE 3x4D 5 HZ Grundfos Pump 9651222 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9651222/cr-1-16-a-fj-a-e-hqqe.html

More information

CR32-4 A-F-A-E-HQQE 3x400D 50 HZ

CR32-4 A-F-A-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CR32-4 A-F-A-E-HQQE 3x4D 5 HZ Grundfos Pump 9612213 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9612213/cr-32-4-a-f-a-e-hqqe.html

More information

Lowara ecocirc and ecocirc PREMIUM THE NEW HIGHLY EFFICIENT CIRCULATORS WITH THE PATENTED ANTI-BLOCK-TECHNOLOGY

Lowara ecocirc and ecocirc PREMIUM THE NEW HIGHLY EFFICIENT CIRCULATORS WITH THE PATENTED ANTI-BLOCK-TECHNOLOGY NE W Lowara ecocirc and ecocirc PREMIUM THE NEW HIGHLY EFFICIENT CIRCULATORS WITH THE PATENTED ANTI-BLOCK-TECHNOLOGY Ecocirc_Premium_uk.indd 1 28/10/13 12.26 How can efficiency even w The simple spherical

More information

UP/UPS-B/UPN Hot Water Service Circulators

UP/UPS-B/UPN Hot Water Service Circulators UP/UPS-B/UPN Hot Water Service Circulators Visions & Values It is the Vision of the Company to achieve our Corporate Mission by providing quality and innovative products and services that give our customers

More information

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016 SECTION 23 21 23 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General Conditions and Division 01 Specification Sections, apply to this Section.

More information

Circulation pumps. Wet rotor circulators and accessories. Heating Potable water Solar Geothermy Condensate

Circulation pumps. Wet rotor circulators and accessories. Heating Potable water Solar Geothermy Condensate Circulation pumps Wet rotor circulators and accessories eating Potable water Solar Geothermy Condensate CATALOGUE / alm produces highly-efficient heating circulation pumps alm has been successfully developing

More information

COMMISSION REGULATION (EU)

COMMISSION REGULATION (EU) L 180/4 Official Journal of the European Union 12.7.2012 COMMISSION REGULATION (EU) No 622/2012 of 11 July 2012 amending Regulation (EC) No 641/2009 with regard to ecodesign requirements for glandless

More information

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems.

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems. Issued 2006/08/01 Section 15131 Pumps Hydronic Systems Page 1 of 6 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal.3 Section 01780

More information

HIGH EFFICIENCY CIRCULATORS. Represented by Taconova Group AG CATALOGUE 2018 EN. easyuse. greatperformance

HIGH EFFICIENCY CIRCULATORS. Represented by Taconova Group AG CATALOGUE 2018 EN. easyuse. greatperformance HIGH EFFICIENCY CIRCULATORS Represented by Taconova Group AG CATALOGUE 218 EN easyuse greatperformance CONTENTS WELCOME...3 HEATING SYSTEMS ES2 6...4 ES2 7...6 ES2 C A 6...8 ES2 ADAPT 6...1 ES2 ADAPT 7...12

More information

CRN A-F-G-E-HQQE 3x400D 50 HZ

CRN A-F-G-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CRN45-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96123118 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn45/96123118/crn-45-2-2-a-f-g-e-hqqe.html

More information

Technical Product Guide

Technical Product Guide FMU - Floor Mixing Unit Boxed set pre-assembled for immediate installation: The FMU Floor Mixing Unit integrates both temperature and flow management, making the single piece unit very easy to install,

More information

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP DS series Industrial End Suction Pumps ISO/DP 5199 www.sterlingpumps.com.au DS series Capacities from: Heads from: 340 to 5,680 m3/h (1,500 to 25,000 USPGM) 21 to 106 metres (70 to 350 feet) Power range

More information

Solar station DKP 6-8 / DKP Installation and Service Manual C

Solar station DKP 6-8 / DKP Installation and Service Manual C EN Solar station DKP 6-8 / DKP 9-20 Installation and Service Manual 300014274-001-C Contents 1 Introduction.............................................................................3 1.1 Used symbols...........................................................................................3

More information

Chilled Water DOAS Fan Powered Terminal Units

Chilled Water DOAS Fan Powered Terminal Units Chilled Water DOAS Fan Powered Terminal Units CHILLED WATER DOAS FAN POWERED TERMINAL UNITS DOAS TERMINAL UNITS FEATURES AND BENEFITS MINIMUM VENTILATION CONTROL The DOAS unit provides the Designer, Owner

More information

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with two or three CM, CMV or CR pumps. 50 Hz

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with two or three CM, CMV or CR pumps. 50 Hz GRUNDFOS DATA BOOKLET Grundfos booster systems with two or three CM, CMV or CR pumps 50 Hz Table of contents 1. Product introduction 3 2. Performance range 4 with CM pumps 4 with CMV pumps 4 with CR pumps

More information

CR5-9 A-FGJ-A-E-HQQE 1x220/240 50HZ

CR5-9 A-FGJ-A-E-HQQE 1x220/240 50HZ GRUNDFOS DATA BOOKLET CR5-9 A-FGJ-A-E-HQQE 1x2/24 5HZ Grundfos Pump 96537532 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96537532/cr-5-9-a-fgj-a-e-hqqe.html

More information

50/60 Hz. ecocirc BASIC Series WET ROTOR CIRCULATORS FOR HEATING, COOLING AND SANITARY SYSTEMS. ErP 2009/125/EC

50/60 Hz. ecocirc BASIC Series WET ROTOR CIRCULATORS FOR HEATING, COOLING AND SANITARY SYSTEMS. ErP 2009/125/EC / Hz ecocirc BASIC Series WET ROTOR CIRCULATORS FOR HEATING, COOLING AND SANITARY SYSTEMS ErP 9//EC Cod. 9 Rev. C Ed./ ecocirc BASIC SERIES INSTALLATION POSITIONS Lowara, ecocirc, Xylect are trademarks

More information

CR A-F-A-V-HQQV 3x400D 50 HZ

CR A-F-A-V-HQQV 3x400D 50 HZ GRUNDFOS DATA BOOKLET CR9-1-1 A-F-A-V-HQQV 3x4D 5 HZ Grundfos Pump 9612486 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9612486/cr-9-1-1-a-f-a-v-hqqv.html

More information

Multibox. Floor Heating Controller Flush individual room control for floor heating systems

Multibox. Floor Heating Controller Flush individual room control for floor heating systems Multibox Floor Heating Controller Flush individual room control for floor heating systems IMI HEIMEIER / Floor Heating Control / Multibox Multibox K, RTL and K-RTL Multibox K, RTL and K-RTL is used for

More information

CR A-F-A-E-HQQE 3x400/ HZ

CR A-F-A-E-HQQE 3x400/ HZ GRUNDFOS DATA BOOKLET CR32--2 A-F-A-E-HQQE 3x/69 5 HZ Grundfos pump 9612212 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/crfam/9612212/cr-32--2-a-f-a-e-hqqe.html

More information

Wash and Clean By Michael Rasmussen, Industry application team, Grundfos, Denmark

Wash and Clean By Michael Rasmussen, Industry application team, Grundfos, Denmark Wash and Clean By Michael Rasmussen, Industry application team, Grundfos, Denmark Introduction Wash & Clean systems for the food processing industry is an utility application that sets high requirements

More information

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES FUNCTION Thermostatic expansion valves are used to regulate and cut-off the flow of the heat transfer fluid that circulates inside airconditioning system terminals (radiators, fan coils, etc.). Thermostat

More information

HTM Circulation Pumps acc. to DIN EN 733 Type NKX

HTM Circulation Pumps acc. to DIN EN 733 Type NKX HTM Circulation Pumps acc. to DIN EN 733 Type NKX General The new NKX pump line replaces our former heat transfer oil circulation pump type NKL s. The outer dimensions of both pump types are identical

More information

GRUNDFOS DATA BOOKLET MAGNA3. Circulator pumps 60 Hz

GRUNDFOS DATA BOOKLET MAGNA3. Circulator pumps 60 Hz GRUNDFOS DATA BOOKLET Circulator pumps 60 z Table of contents 1. Product introduction 3 Features and benefits 3 Applications 3 2. Performance range 4 4 D single-head operation 5 D twin-head operation 6

More information

CR20-07 A-F-A-E-HQQE 3x400/ HZ

CR20-07 A-F-A-E-HQQE 3x400/ HZ GRUNDFOS DATA BOOKLET CR2-7 A-F-A-E-HQQE 3x4/69 5 HZ Grundfos pump 965513 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/crfam/965513/cr-2-7-a-f-a-e-hqqe.html

More information

Multibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off

Multibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off Multibox 4 Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off IMI HEIMEIER / Floor Heating Control / Multibox 4 Multibox 4 RTL and K-RTL and K-RTL is

More information

EBARA. Submersible Non-clog Pump Model DLFU Model DVFU Model DDLFU

EBARA. Submersible Non-clog Pump Model DLFU Model DVFU Model DDLFU EBARA Submersible Non-clog Pump Model DLFU Model DVFU Model DDLFU water wastewater EBARA International Corporation Standard Pump Division S ubmersible Non-clog Pump Model DLFU DVFU DDLFU Features Watertight

More information

SECTION STEAM CONDENSATE PUMPS

SECTION STEAM CONDENSATE PUMPS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 23 22 23 STEAM CONDENSATE PUMPS SPEC WRITER NOTES: 1. Delete between // ---- // if not applicable to project. Also delete any other item or paragraph not applicable

More information

Information for installers. Simple to install, simply ready for the future. Wilo-Yonos PICO, Wilo-Stratos PICO, Wilo-Stratos, Wilo-Yonos MAXO.

Information for installers. Simple to install, simply ready for the future. Wilo-Yonos PICO, Wilo-Stratos PICO, Wilo-Stratos, Wilo-Yonos MAXO. Pioneering for You Information for installers. Simple to install, simply ready for the future. Wilo-Yonos PICO, Wilo-Stratos PICO, Wilo-Stratos, Wilo-Yonos MAXO. 2 ErP Directive 3 The ErP Directive for

More information

Flush individual room control for floor heating systems

Flush individual room control for floor heating systems Multibox Flush individual room control for floor heating systems Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGiNEERiNG ADVANTAGE Multibox is used for decentralized control

More information

NEW Lowara ecocirc PRO The new high efficiency domestic hot water PumPs with automatic air venting function and TheRmaL insulation shell

NEW Lowara ecocirc PRO The new high efficiency domestic hot water PumPs with automatic air venting function and TheRmaL insulation shell NEW Lowara ecocirc PRO The new high efficiency domestic hot water pumps with automatic air venting function and thermal insulation shell ecocirc PRO domestic hot water circulation pumps. Areas of use.

More information

Whether you are coming in from a cold night, a heavy rain shower or a long day at work nothing is more inviting then a Joule Underfloor Heating

Whether you are coming in from a cold night, a heavy rain shower or a long day at work nothing is more inviting then a Joule Underfloor Heating Underfloor Heating 2 Whether you are coming in from a cold night, a heavy rain shower or a long day at work nothing is more inviting then a Joule Underfloor Heating System. The warmth underfoot can not

More information

1 Declaration of conformity

1 Declaration of conformity ENERGY SAVING 1 Declaration of conformity We Taco Italia S.r.l. declare under our sole responsibility that the family of products ENERGY SAVING to which this declaration relates are in conformity with

More information

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting For reversed flow direction Thermostatic Radiator Valves Thermostatic valve body with and without presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / For reversed flow direction For reversed

More information

CRN90-1 A-F-G-V-HQQV 3x400D 50 HZ

CRN90-1 A-F-G-V-HQQV 3x400D 50 HZ GRUNDFOS DATA BOOKLET CRN9-1 A-F-G-V-HQQV 3x4D 5 HZ Grundfos Pump 96124237 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn9/96124237/crn-9-1-a-f-g-v-hqqv.html

More information

Taco 00 Series Cartridge Circulators

Taco 00 Series Cartridge Circulators Water Circulation Pumps & Circulators Taco 00 Series Cartridge Circulators For over 70 years, Taco has led the industry with the highest quality circulators you can buy. Designed for a wide range of residential

More information

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function Thermostatic regulating unit for heating systems 66 series ACCREDITED ISO 9 FM 6 8/7 GB replaces dp 8/ GB Function The thermostatic regulating unit performs the function of keeping the flow temperature

More information

Condensate Boiler Feed Water Make-Up

Condensate Boiler Feed Water Make-Up 1144 Utica Ave, Brooklyn, NY 1103 July 0 New Catalogue Release Bulletin 9C.01 Low Inlet Condensate Receiver (7 from floor) Close Grained Cast Iron Simplex and Duplex Design To 0,000 SQ-Ft EDR Pump Capacity

More information

Installation and Commissioning Instructions

Installation and Commissioning Instructions Installation and Commissioning Instructions FMU Floor Mixing Unit with Lowara Ecocirc Class A Pump Pre-assembled TM Thermostatic Mixing Control Group and manifold with either lockshields or flowmeters,

More information

SL EX.4.51D

SL EX.4.51D GRUNDFOS DATA BOOKLET SL1.1.1.75.EX.4.51D Grundfos pump 962669 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/sl1/962669/sl1-1-1-75-ex-4-51d-c.html

More information

Company name: Created by: Phone:

Company name: Created by: Phone: Position Qty. Description 1 SL1..1.55..6G.C Product o.: 9655 ote! Product picture may differ from actual product on-self-priming, single-stage, centrifugal pump designed for handling wastewater, process

More information

THERMOSTATIC SINGLE-PIPE AND DOUBLE-PIPE VALVES

THERMOSTATIC SINGLE-PIPE AND DOUBLE-PIPE VALVES ST.07.05.00 THERMOSTIC SINGLE-PIPE AND DOUBLE-PIPE VALVES 1. Art.1420 THERMOSTIC SINGLE-PIPE VALVE Single-pipe valves allow manual, thermostatic or thermo-electric regulation. Separation of the lockshield

More information

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

4VH and 4VHX. 4 Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction 4VH and 4VHX 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction DURABLE MOTOR WILL DELIVER MANY YEARS OF RELIABLE SERVICE Oil-filled motor for maximum heat dissipation

More information

ecocirc E1 Domestic hot water / Sanitary pumps Unequalled economically! Only 8 Watt!

ecocirc E1 Domestic hot water / Sanitary pumps Unequalled economically! Only 8 Watt! Domestic hot water / Sanitary pumps ecocirc E1 Instant hot water at every tap More comfort Saves water and energy e c o c i r c E 1 Unequalled economically! Only 8 Watt! saves 68% electricity compared

More information

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting Calypso exact Thermostatic Radiator Valves With stepless precision presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Calypso exact Calypso exact Calypso exact thermostatic valve bodies are

More information

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with 2 or 3 CM, CMV or CR pumps 50 Hz

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with 2 or 3 CM, CMV or CR pumps 50 Hz GRUNDFOS DATA BOOKLET Grundfos booster systems with 2 or 3 CM, CMV or CR pumps 50 Hz Table of contents 1. Product data 3 Introduction 3 Performance range 4 Product range 6 Type key 9 Operating conditions

More information

KEENER GRINDER PUMPS

KEENER GRINDER PUMPS KEENER GRINDER PUMPS RDSGP1-2021-50Hz 2 HP Grinder Pump Replacement Grinder Pump Direct Interchangeability Double Mechanical Seal Silicon Carbide (Main) - Grit Resistant Carbon Ceramic (Secondary) Dual

More information

Affordable efficiency!

Affordable efficiency! Lowara Ecocirc THE REVOLUTIONARY HIGHLY EFFICIENT CIRCULATORS FOR DOMESTIC HEATING WITH THE SIMPLE AND SHAFTLESS SPHERICAL MOTOR DESIGN AND PATENTED ANTI-BLOCK-TECHNOLOGY. Affordable efficiency! Approximately

More information

KRAL Screw Pumps. L Series.

KRAL Screw Pumps. L Series. KRAL Screw Pumps. L Series. Our new Medium Pressure Pump The new L pump makes life easier sturdy, with a low wear rate and easy to maintain. How the L pump fits into the KRAL product Applications. range.

More information

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES FUNCTION Thermostatic expansion valves are used to regulate and cut-off the flow of the heat transfer fluid that circulates inside airconditioning system terminals (radiators, fan coils, etc.). Thermostat

More information

STEAM TRAPS

STEAM TRAPS STEAM TRAPS 08.2016 info@ayvaz.com www.ayvaz.com SELECTION OF STEAM TRAPS In order to get maximum efficiency and service life from the steam lines and steam related systems, it is crucial to make the correct

More information

Systems for central heating

Systems for central heating www.far.eu Highlight Systems and Components for central heating Components for renewable energy systems Pressfar Fittings Presetting valves and thermostatic head Balancing devices Zone valves Metering

More information

Selfpriming Centrifugal Pumps. Type HZS/HZSA

Selfpriming Centrifugal Pumps. Type HZS/HZSA Selfpriming Centrifugal Pumps Type HZS/HZSA General The selfpriming multistage DICKOW-centrifugal pump is designed for handling hydrocarbons and other volatile liquids. The HZS-type is used in tank farms,

More information

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold Dynalux Floor Heating Manifolds Underfl oor heating circuit manifold IMI HEIMEIER / Floor Heating Control / Dynalux Dynalux Dynalux adjusts the flow rate in the individual heating circuits directly in

More information

Use. Functions. Key function. Other functions

Use. Functions. Key function. Other functions 2 466 Heating Control System RVP102/SET Heating control system for use in smaller plants. Control of boiler temperature through direct burner control, pump control, weather-compensated setpoint (with or

More information

Automatic balancing valves ASV-PV (new generation) DN 32-50

Automatic balancing valves ASV-PV (new generation) DN 32-50 Automatic balancing valves ASV-PV (new generation) DN 32-50 ASV-PV DN 32-50 Description ASV whiteboard animation SMT/SI ASV valves are automatic balancing valves. Together with Danfoss presetting radiator

More information

Thermostatic valve bodies

Thermostatic valve bodies Thermostatic valve bodies for single pipe heating systems Thermostatic valves with radiator connection systems IMI HEIMEIER / Thermostatic heads and Radiator valves / Thermostatic valve bodies for single

More information

Multilux 4-Eclipse-Set

Multilux 4-Eclipse-Set Multilux -Eclipse-Set Design-Edition with two-point connection, angle and straight type, for R / and connection, with automatic flow limitation IMI HEIMEIER / Design-Edition / Multilux -Eclipse-Set Multilux

More information

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE TEcHnIcal InsTRucTIons PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE PHRIE 095 PHRIE 1 PHIE 095 PHIE 1 PHRIE 155 PHRIE 157 PHRIE 175 PHRIE 177 PHRIE 195 PHRIE 197 PHRIE 7 PHRIE

More information

SECTION PLUMBING EQUIPMENT

SECTION PLUMBING EQUIPMENT PART 1 GENERAL 1.01 SECTION INCLUDES A. Water heaters. B. Packaged water heating systems. C. Domestic water heat exchangers. D. Water storage tanks. E. Water softeners. F. Reverse osmosis equipment. G.

More information

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1 A AD Oil burners fuel unit deltapumps.com DE116-0709 A-AD_en_0709.pdf - 16.11.09 Page 1/1 Oil burners fuel unit Type A, AD 1- Applications The DELTA aluminium fuel unit type A is an efficient and modern

More information

ON A POSSIBLE COMMISSION REGULATION AMENDING COMMISSION REGULATION (EC)

ON A POSSIBLE COMMISSION REGULATION AMENDING COMMISSION REGULATION (EC) WORKING DOCUMT ON A OSSIBLE COMMISSION REGULATION AMDING COMMISSION REGULATION (EC) No 641/2009 of 22 July 2009 with regard to ecodesign requirements for glandless standalone circulators and glandless

More information

TECHNICAL. Series 18. Pump Packages

TECHNICAL. Series 18. Pump Packages TECHNICAL S Y S T E M S Series 18 Pump Packages Series 18 Pump Packages Standard Features Close-coupled, end-suction, centrifugal pumps Mounted and wired pump starters Hand-Off-Auto switch for each pump

More information

Wilo Top S Wet Rotor Circulation Pumps. Engineering Specification

Wilo Top S Wet Rotor Circulation Pumps. Engineering Specification Wilo Top S Wet Rotor Circulation Pumps Engineering Specification PART 1 - GENERAL 1.1 SUMMARY A. Furnish and install circulating pumps consistent with the hydronic system s performance and requirements.

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

Metering systems 0548EN April 2014

Metering systems 0548EN April 2014 08EN April 0 0U8 GEY - Y - Y (GE- series) 900 000/ 00 00A/ 800 00L/ Versions and product codes Product code Type Heat exchanger nominal power GEY, - GEY and production GEY and production Table - Product

More information

FX5 Series Explosion-Proof Electric Air Heaters

FX5 Series Explosion-Proof Electric Air Heaters FX5 Series Explosion-Proof Electric Air Heaters Ruffneck FX5 heaters are C UL US certified for use in hazardous locations. They are designed for the harshest environments such as: dry indoor industrial

More information

Sekamatik series PREFABRICATED LIFTING STATIONS FOR RESIDENTIAL, COMMERCIAL OR INDUSTRIAL APPLICATIONS

Sekamatik series PREFABRICATED LIFTING STATIONS FOR RESIDENTIAL, COMMERCIAL OR INDUSTRIAL APPLICATIONS Sekamatik series PREFABRICATED LIFTING STATIONS FOR RESIDENTIAL, COMMERCIAL OR INDUSTRIAL APPLICATIONS Wastewater is a demanding process, performance, day in day out. Xylem challenges, providing trusted

More information

CPO N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. ASME/ANSI B73.1 Chemical Process Pump. Springer Pumps, LLC

CPO N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. ASME/ANSI B73.1 Chemical Process Pump. Springer Pumps, LLC N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPO ASME/ANSI B73.1 Chemical Process Pump Tel: 866-777-66 Horizontal Split Case For more than 6 years the name Ruhrpumpen TM has been synonymous worldwide

More information

Oil burners fuel unit with solenoid valve

Oil burners fuel unit with solenoid valve Oil burners fuel unit with solenoid valve Type VM www.deltapumps.com VM1 - VM4U flanged Certified Quality System Printed in Germany VM_e.pdf - 18.05.08 Page 1/6 Oil burners fuel unit with solenoid valve

More information

Oil burners fuel unit with solenoid valve

Oil burners fuel unit with solenoid valve Oil burners fuel unit with solenoid valve Type VM www.deltapumps.com VM1 - VM4U flanged Certified Quality System Printed in Italy - DE112/0404 Oil burners fuel unit with solenoid valve Type VM The DELTA

More information

PAPANTONATOS. We supply clean water and remove waste water. P u m p s s e r v ic e & e n g i nee r in g. submersible pumps. s e w a g e p u m p s

PAPANTONATOS. We supply clean water and remove waste water. P u m p s s e r v ic e & e n g i nee r in g. submersible pumps. s e w a g e p u m p s PAPANTONATOS P u m p s s e r v ic e & e n g i nee r in g We supply clean water and remove waste water s e w a g e p u m p s submersible pumps The Company QUALITY WHICH REDUCES PUMPING COSTS For over 45

More information

Thermostatic three-way valve body. Thermostatic Radiator Valves without presetting, with automatic bypass control

Thermostatic three-way valve body. Thermostatic Radiator Valves without presetting, with automatic bypass control Thermostatic three-way valve body Thermostatic Radiator Valves without presetting, with automatic bypass control IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Thermostatic three-way valve body

More information

Data sheet: Wilo-RainSystem AF Comfort MC 304

Data sheet: Wilo-RainSystem AF Comfort MC 304 Data sheet: Wilo-RainSystem AF Comfort MC 304 Pump curves Wilo-RainSystem AF Comfort H/m 50 Wilo-RainSystem AF Comfort Approved fluids (other fluids on request) Pure water without settling sediment Rainwater

More information

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus. 24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers Enerwa / EnerwaPlus www.warmhaus.com Condensing-ErP Premix System Boilers 24/31-28/35-33/40 kw Warmhaus wall-hung gas combi boilers

More information

Understanding Head Pressure Control. Walter H Langille, M.A.Sc., P.Eng Sales Engineer KeepRite Refrigeration

Understanding Head Pressure Control. Walter H Langille, M.A.Sc., P.Eng Sales Engineer KeepRite Refrigeration Understanding Head Pressure Control Walter H Langille, M.A.Sc., P.Eng Sales Engineer KeepRite Refrigeration WE WILL LOOK AT: 1. Why We Need Head Pressure Control? 2. How Do We Control Head Pressure - Methods?

More information