Solar station DKP 6-8 / DKP Installation and Service Manual C

Size: px
Start display at page:

Download "Solar station DKP 6-8 / DKP Installation and Service Manual C"

Transcription

1 EN Solar station DKP 6-8 / DKP 9-20 Installation and Service Manual C

2 Contents 1 Introduction Used symbols General Electrical compliance Safety instructions and recommendations Technical description General description Technical characteristics Pump unit Accelerator pump Airstop/degasser Antithermosiphon valve Installation Fitting the vent device (Airstop) to the solar heat exchanger inlet Fitting the pumping unit to the solar heat exchanger outlet Fitting to the solar station, steps to be followed: Connecting the pipe circuit to the solar station Assembling the pipes Hydraulic connections Wall connection kit for expansion vessel Dimensioning the expansion vessel Electrical connection Commissioning Spare parts - DKP 6-8 / DKP DKP 6-8 / DKP /07/ C

3 1 Introduction 1.1 Used symbols Caution danger Risk of injury and damage to equipment. Attention must be paid to the warnings on safety of persons and equipment. Specific information Information must be kept in mind to maintain comfort. Reference Refer to another manual or other pages in this instruction manual. 1.2 General The manufacturer is not liable for any improper use of the appliance or failure to maintain or install the unit correctly (the user shall take care to ensure that the system is installed by a qualified fitter). For a proper operating of the boiler, follow carefully the instructions. Keep these instructions in a safe place close to the appliance. 1.3 Electrical compliance This product complies to the requirements to the European Directives and following standards: /95/EC Low Voltage Directive Reference Standard: EN /108/EC Electromagnetic Compatibility Directive Reference Standards: EN / EN / EN Safety instructions and recommendations Any operation on the installation must be performed by a qualified technician respecting professional regulations and in accordance with this document. Service the appliance regularly to ensure that it operates correctly. To take advantage of the guarantee, no modifications must be made to the appliance. 06/07/ C DKP 6-8 / DKP

4 3 Technical description 3.1 General description The solar station includes a safety valve, an expansion vessel connection and a filling device. 3.2 Technical characteristics Solar station Height (with insulation) 630 mm Width (with insulation) 200 mm Depth 190 mm Maximum operating pressure 6 bar Maximum operating temperature 120 C (on occasion 180 C) Safety devices Safety valve 6 bar Connection kit for expansion vessel current Retaining / signalling components Spherical liner valve Mk3/4 Antithermosiphon valve Resistance 200 mm water columns Execution Mod. PPS can be fitted Maximum operating temperature 180 C Sealing material VILTON/EPDL O-ring 180 C AFM 34 gaskets 200 C Insulation Material EPP 3.3 Pump unit Accelerator pump High manometric pump: ST 20/6 - ST 20/9 Power exchanged 4 DKP 6-8 / DKP /07/ C

5 3.3.2 Airstop/degasser The solar station is fitted with a permanent degassing device (Airstop) on the flow pipes. The circulator conveys any air bubbles present to the Airstop system. The air contained in the heatexchanging medium is collected in the degasser. The degasser must be vented from time to time (several times after commissioning, then after one week followed by a further check after one month). For optimum efficiency, the solar installation must be vented using the degasser every six months. After venting, the installation operating pressure must be reset Antithermosiphon valve The check valve is included in the ball valve on the red thermometer and it is characterized by an opening pressure of 200 mm water column. 1. To fill, vent and rinse the installation, the antithermosiphon valves must be open. To open them, use a 14 mm openended spanner and open the valves half way. The ball in the valve lifts the check valve (45 ). 2. When the installation is operating, the ball valves must be fully open. The antithermosiphon valve operates when the stop cock is in the open position. 06/07/ C DKP 6-8 / DKP

6 4 Installation 4.1 Fitting the vent device (Airstop) to the solar heat exchanger inlet Screw the vent device to the top solar connection. First place the gasket in the coupling nut. 4.2 Fitting the pumping unit to the solar heat exchanger outlet Hold the pumping unit in place with the insulation housing on the tank and screw it onto the bottom solar connection. First place the gasket in the coupling nut. M A 6 DKP 6-8 / DKP /07/ C

7 4.3 Fitting to the solar station, steps to be followed: 1. Attach the control system to the mounting base frame provided. 6. Remove the part of the casing in plexiglass from the front insulation housing. Fit the front insulation housing without plexiglass but with control system to the solar station. The control system is now fitted and can be set from the front. 7. Drill a hole 8 in the side cover and feed through the DHW sensor. 8. Fitting the DHW sensor. 9. Refit the cover M A 2. Secure the control system on the mounting base frame to the station, above the pump. D B 10. Connect the connector delivered with the solar station to the circulator. M A 3. Fit the wiring between the pump and the control system. 4. Connect the tank sensors and the solar collectors. 5. Make the 230 V connection (qualified personnel only). Electrical connections, cf. commissioning the Diemasol A control system. 06/07/ C DKP 6-8 / DKP

8 4.4 Connecting the pipe circuit to the solar station Recommendation: connect the flow and the return according to the instructions in the illustration. If need be, it is nonetheless possible to modify the return by turning the valve block from left to right. After completing the solar circuit, filling it and checking the pressure, it is possible to fit the front housing to the station. 4.5 Assembling the pipes If connecting by brazing: - Strong brazing on joints to be brazed without scouring agent/ paint stripper. - Remove the rubber gasket before brazing. - Put the gasket back in place after brazing. The arrow on the pump must be pointing towards the roof ridge. Make the connections using clamping ring screw connections. With small systems, use De Dietrich propylene glycol containers to recover fluid under the safety valve discharge pipe. 8 DKP 6-8 / DKP /07/ C

9 4.6 Hydraulic connections Wall connection kit for expansion vessel The connection kit includes a 0.5 metre long stainless steel hose with nuts for pipe unions and flat gaskets for both sides as well as an arm and a screw connection supporting the expansion vessel. The connecting hose is arranged in such a way as to be able to fit the expansion vessel to the wall, beside the hot water tank. If the appliance is not installed against a wall, the installer must fit an extension (copper pipe) connecting the expansion vessel or connect the expansion vessel to the conduit coming out of the top of the hot water tank. If, due to lack of space, the arm cannot be mounted as such, it can be used as a floor-standing support. In this case, the opened expansion vessel is fitted in the horizontal position Dimensioning the expansion vessel The volume of the expansion vessel depends above all on the volume likely to be vapourised when the installation is switched off. For this reason, the expansion vessel must be chosen according to the number of collectors. When the number of collectors is high, parallel expansion vessels can be fitted. PRO PRO C POWER Collecto r surface Number of panels Total length of the pipe A/R < 30m A/R >30m Volume of the expansion vessel m 2 ø ext. (mm) ø ext. (mm) litres 5 15/18 15/ /18 15/ / / /18 15/ /18 15/ /18 15/ /18 15/ Expansion vessel capacity: Pre-inflation and pressure in the installation must be adapted to the configuration of the installation. Package no. Volume of the expansion vessel EG EG EG /07/ C DKP 6-8 / DKP

10 4.7 Electrical connection Make the 230 V connection (qualified personnel only). Electrical connections, cf. commissioning the Diemasol A control system. 5 Commissioning See: Domestic hot water tank manual. 10 DKP 6-8 / DKP /07/ C

11 6 Spare parts - DKP 6-8 / DKP 9-20 To order a spare part, quote the reference number next to the part required. 06/07/ C 9 A000646A Ref. Reference Description Insulation for DKP 6-8 solar station Part in plexiglass R 3/4 connection cross /4 double nipple Rp 3/4 return valve with antithermosiphon valve Circulator ST20/ DKP Circulator ST20/9-3 - DKP Flow valve Elbow R 3/ Drain cock Bleeder valve stopper 3/8" (after 06/2007) Degasser M/M 3/4" (after 06/2007) Air vent R 3/4 (before 06/2007) Safety device holder Solid plug R 3/ Manometer connection point bar manometer Ref. Reference Description bar safety valve Sachet of gaskets for DKP 6-8 solar station x3 O-ring 06/07/ C DKP 6-8 / DKP

12 Copyright All technical and technological information contained in these technical instructions, as well as any drawings and technical descriptions supplied, remain our property and shall not be multiplied without our prior consent in writing. Subject to alterations. 06/07/09

CIRCO 6 Solar Circulation Unit

CIRCO 6 Solar Circulation Unit TECHNICAL INFORMATION / INSTALLATION INSTRUCTIONS CIRCO Solar Circulation Unit CIRCO Solar Circulation Unit in combination with the intelligent SUNGO controllers, it is the safe and reliable heart of a

More information

Installation and operation instructions Solar stations SolarBloC midi Premium DN 20 SolarBloC maxi Premium DN 25

Installation and operation instructions Solar stations SolarBloC midi Premium DN 20 SolarBloC maxi Premium DN 25 PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 E-mail: info@paw.eu, Web: www.paw.eu Installation and operation instructions Solar stations SolarBloC

More information

Installation and instruction manual SOLAR STATION

Installation and instruction manual SOLAR STATION INSTALLATION AND INSTRUCTION MANUAL SOLAR STATION Installation and instruction manual SOLAR STATION SST 25-1E / SST25-2E EN April 2015 1 Table of contents Usage 3 Warranty 3 Safety instructions and symbol

More information

TRIO DT 350/3 DIETRISOL. Solar domestic hot water tanks. Installation instructions. Instructions for use. Technical instructions.

TRIO DT 350/3 DIETRISOL. Solar domestic hot water tanks. Installation instructions. Instructions for use. Technical instructions. DIETRISOL TRIO DT 350/3 Solar domestic hot water tanks English 07/11/06 Installation instructions Instructions for use 8980N146A Technical instructions Contents Introduction.................................................................................3

More information

BSC...E - BSP...E - BESC...E

BSC...E - BSP...E - BESC...E INISOL DUO E DIETRISOL DUO E Solar hot water calorifer BSC...E - BSP...E - BESC...E EN User Guide 0007781-001-01 Contents 1 Introduction.............................................................................

More information

WHE 2.24 / WHE 2.24 FF

WHE 2.24 / WHE 2.24 FF EN Wall-hung gas boilers WHE 2.24 WHE 2.24 FF User Guide 300011777-001-C . Contents 1 Introduction.............................................................................3 1.1 Symbols used...........................................................................................3

More information

Installation, operation and care Wall-mounted electric boiler MP THL nr. - rev 02

Installation, operation and care Wall-mounted electric boiler MP THL nr. - rev 02 Installation, operation and care Wall-mounted electric boiler MP 4 150206 THL nr. - rev 02 Contents Notes... 3 Safety and handling... 4 Operation... 5 Technical data... 6 Pipe installation... 8 System

More information

Solar heating systems

Solar heating systems 03 energy efficiency Compact, "ALL-IN-ONE" solar system Solar panel for swimming pools Hydraulic components Drain-Unit: dual hydraulic unit with drain back system Drain-Unit: hydraulic unit with drain-back

More information

AGS 2 SOLAR PUMP STATION FOR SOLAR DOMESTIC HOT WATER SYSTEMS UK/IE

AGS 2 SOLAR PUMP STATION FOR SOLAR DOMESTIC HOT WATER SYSTEMS UK/IE INSTRUCTION MANUAL INSTALLATION AND SERVICING AGS 2 SOLAR PUMP STATION FOR SOLAR DOMESTIC HOT WATER SYSTEMS UK/IE About this manual These installation and maintenance instructions contain important information

More information

MAIN FEATURES ADVANTAGES BENEFITS BOSS TRANSFORMER COMBI HF 110 CHEMICAL AND PHYSICAL FEATURES PACKAGING FEATURES

MAIN FEATURES ADVANTAGES BENEFITS BOSS TRANSFORMER COMBI HF 110 CHEMICAL AND PHYSICAL FEATURES PACKAGING FEATURES BOSS TRANSFORMER COMBI HF 110 Power flushing pump with antacid vertical axis. Suitable for domestic and medium dimensions systems. Practical trolley design with 110 litres tank. COD. 301301006 CHEMICAL

More information

PRIUX HOME D. High-efficiency double circulating pumps Heating Air conditioning 50 Hz OPERATING RANGE APPLICATIONS BENEFITS

PRIUX HOME D. High-efficiency double circulating pumps Heating Air conditioning 50 Hz OPERATING RANGE APPLICATIONS BENEFITS OPERATING RANGE Flow rate of up to 7 m /h* Manometric head of up to 8 mwc Max. operating pressure bar Min. suction pressure, bar at 9C Temperature range -C at 9C Max. ambient temperature +C EEI-Part Priux

More information

DEVIATING VALVES ART K063

DEVIATING VALVES ART K063 FUNCTION The flow diverter valve Art.307 makes it possible to supply a branch circuit. Prepared to receive our electro-thermal controls Art. 978, 979, 980 or our thermostatic heads with remote sensor Art.

More information

CONNECT SOLAR MR - 7,5m

CONNECT SOLAR MR - 7,5m Installation Manual CONNECT SOLAR MR - 7,m Solar Solar station EN Installation Manual 0 6 GENERAL INFORMATION ENGLISH General information This - comprises pages. Rev. manual, Code RANGE MODEL CODE CONNECT

More information

Remeha. Fuel oil/gas boilers P 520. Installation and Service Manual A

Remeha. Fuel oil/gas boilers P 520. Installation and Service Manual A Remeha Fuel oil/gas boilers EN Installation and Service Manual 300016859-001-A 63115 Declaration of conformity The appliance complies with the standard model described in declaration of compliance. It

More information

Installation & Operation Manual Models: TSU

Installation & Operation Manual Models: TSU TSU-I-O Rev A Installation & Operation Manual Models: TSU 150-940 CAUTION: This appliance is not intended for potable water. This manual must only be used by a qualified heating installer / service technician.

More information

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions EN 0 / 0 / 00 / 800 Installation, Operating and Servicing Instructions excellence in hot water EN Y000.D EN INDEX Warnings Who should read these instructions Symbols Recommendations Applicable standards

More information

Crown Boiler Company

Crown Boiler Company Crown Boiler Company 1 Phantom Boiler System Combi Kit Instruction Manual I Product Description This kit adds the ability to generate DHW, as well as heat, ( combi capability) to select Phantom models

More information

HeatMaster. Assembling and installation instructions. 201 Booster. HeatMaster. HeatMaster. 200N (Gas) Booster ENGLISH FRANCAIS NEDERLANDS ESPAÑOL

HeatMaster. Assembling and installation instructions. 201 Booster. HeatMaster. HeatMaster. 200N (Gas) Booster ENGLISH FRANCAIS NEDERLANDS ESPAÑOL Heataster Assembling and installation instructions Heataster 201 Booster Heataster 200N (Gas) Booster EN 1 WANINGS 3 Who should read these instructions 3 Symbols 2 Applicable standards 2 ecommendations

More information

General System Layout Sketch

General System Layout Sketch General System Layout Sketch EZ-37 Solar Panels PV panel Glycol Fill Valve Expansion Tank ` 1 Introduction This document describes how to install a Heliatos GH type solar water heating system. These systems

More information

Components for solar heating systems

Components for solar heating systems solarorkli Components for solar heating systems Components for heating and plumbing Components for solar heating systems Manifolds and distribution equipment Thermostatic valves Manual valves Motorised

More information

8008 CIRCULATION UNIT FOR SOLAR THERMAL SYSTEMS, FLOW AND RETURN.

8008 CIRCULATION UNIT FOR SOLAR THERMAL SYSTEMS, FLOW AND RETURN. 8008 CIRCULATION UNIT FOR SOLAR THERMAL SYSTEMS, FLOW AND RETURN. FUNCTION: Circulation units for solar thermal systems are used in the primary circuit of solar heating systems to control the temperature

More information

HKF 8180 Operating instructions

HKF 8180 Operating instructions Operating instructions EN Version 1.0en /Edition 05/2013 Contents 1 Important basic information... 3 1.1 Limitation of liability... 3 1.2 Operator's responsibilities... 3 1.3 Documentation... 3 1.3.1 Content

More information

Powerstock Storage Tank

Powerstock Storage Tank Powerstock Storage Tank Models ST300, ST500, ST750 & ST1000 INSTALLATION, COMMISSIONING AND SERVICING INSTRUCTIONS THE POWERSTOCK STORAGE TANK IS INTENDED FOR USE AS A COMMERCIAL APPLIANCE. PUBLICATION

More information

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHTS200A EKHTS260A EKHTSP200AA EKHTSP260AA

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHTS200A EKHTS260A EKHTSP200AA EKHTSP260AA INSTALLATION MANUAL Domestic hot water tank for air to water heat pump system EKHTS00A EKHTS60A EKHTSP00AA EKHTSP60AA 6 7 x x x x x x x 0 mm 0 D B >0 C >0 0 >0 A >600 H 0 Ø60 0 0 77 8 6 7 778 6 0 6 6 00

More information

USER S MANUAL ATH WH220

USER S MANUAL ATH WH220 USER S MANUAL ATH WH220 INDEX INTRODUCTION... - 3 - General information s... - 3 - Description of pneumatic jack... - 4 - Operation of jack... - 5 - Technical data... - 6 - Dimension drawing... - 6 - INSTALLATION...

More information

AGS 5/5E, AGS 10/10E INSTALLATION AND SERVICING INSTRUCTIONS SOLAR PUMP STATIONS FOR SEALED SOLAR HEATING SYSTEMS AND INDIRECT FED DOMESTIC HOT WATER

AGS 5/5E, AGS 10/10E INSTALLATION AND SERVICING INSTRUCTIONS SOLAR PUMP STATIONS FOR SEALED SOLAR HEATING SYSTEMS AND INDIRECT FED DOMESTIC HOT WATER INSTALLATION AND SERVICING INSTRUCTIONS SOLAR PUMP STATIONS AGS 5/5E, AGS 0/0E FOR SEALED SOLAR HEATING SYSTEMS AND INDIRECT FED DOMESTIC HOT WATER 7747006489.00-.SD CONTENTS CONTENTS Safety instructions

More information

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions ENGLISH 0 / 0 / 0 / 0 / 00 Installation, Operating and Servicing Instructions FRANCAIS NEDERLANDS ESPAÑOL Y000.A EN ESPAÑOL NEDERLANDS FRANCAIS ENGLISH INDEX WARNING Who should read these instructions

More information

Enzo Concealed Shower Mixing Valve

Enzo Concealed Shower Mixing Valve Enzo Concealed Shower Mixing Valve EZ40010CP, EZ40013CP & EZ40014CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible.

More information

Installation and Operation Manual IDRA PLUS DS. Solar Solar storage cylinder. Installation and Operation Manual

Installation and Operation Manual IDRA PLUS DS. Solar Solar storage cylinder. Installation and Operation Manual Installation and Operation Manual IDRA PLUS DS Solar Solar storage cylinder EN Installation and Operation Manual GENERAL INFORMATION This - comprises pages. Rev. manual, Code ENGLISH General information

More information

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l Installation instructions for contractors VIESMANN Vitocell 300-B Type EVBA-A Dual mode DHW cylinder, 300 and 500 l VITOCELL 300-B 1/2017 Dispose after installation. Safety instructions Please follow these

More information

Enzo Safe Touch Thermostatic Shower EZ10010CP & EZ10014CP

Enzo Safe Touch Thermostatic Shower EZ10010CP & EZ10014CP Enzo Safe Touch Thermostatic Shower EZ10010CP & EZ10014CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot

More information

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE TEcHnIcal InsTRucTIons PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE PHRIE 095 PHRIE 1 PHIE 095 PHIE 1 PHRIE 155 PHRIE 157 PHRIE 175 PHRIE 177 PHRIE 195 PHRIE 197 PHRIE 7 PHRIE

More information

Operating Instructions. Boilermag XL Filter. High Intensity Magnetic Separator

Operating Instructions. Boilermag XL Filter. High Intensity Magnetic Separator Operating Instructions Boilermag XL Filter High Intensity Magnetic Separator Technical data is subject to change without notice due to technical innovation! Eclipse Magnetics Ltd Atlas Way, Atlas North,

More information

EXTREME 1 Reverse Osmosis System

EXTREME 1 Reverse Osmosis System EXTREME 1 Reverse Osmosis System Leader Evaporator Co., Inc. 49 Jonergin Drive Swanton, VT 05488 Tel: 802-868-5444 www.leaderevaporator.com TABLE OF CONTENTS INTRODUCTION... 4 THEORY OF OPERATION... 4

More information

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION SOLARCYL IM/SC INSTALLATION MANUAL This manual gives detailed advice for installation and should be read carefully prior to fitting any unvented

More information

Hakki Pilke Raven spare parts manual

Hakki Pilke Raven spare parts manual 1 ENGLISH Hakki Pilke Raven spare parts manual Valimotie 1, FI-85800 Haapajärvi, FINLAND Tel. +358 8 772 7300, Fax +358 8 772 732 info@maaselankone.fi, www.maaselankone.fi 2 Table of contents 1 Upper section

More information

MCR 24 MCR 24/28 MI MCR 30/35 MI MCR 34/39 MI

MCR 24 MCR 24/28 MI MCR 30/35 MI MCR 34/39 MI Vivadens EN Wall-hung gas condensing boilers MCR 24 MCR 24/28 MI MCR 30/35 MI MCR 34/39 MI User Guide 300015874-001-B Contents 1 Introduction...4 1.1 Used symbols...4 1.2 Abbreviations...4 1.3 General...4

More information

Aquastrom T plus Thermostatic valve with adjustable temperature control range and fixed residual volume flow for circulation pipes

Aquastrom T plus Thermostatic valve with adjustable temperature control range and fixed residual volume flow for circulation pipes Thermostatic valve with adjustable temperature control range Technical information Tender specification: Oventrop thermostatic valve Aquastrom T plus with presetting for circulation pipes. Thermal control

More information

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil eco. Item no: Z-3278

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil eco. Item no: Z-3278 Illustration shows item no Z-3278 Operating manual BlueMobil eco Item no: Z-3278 Original operating manual Important Copyright It is essential that you read this manual thoroughly before the initial operation

More information

IST 03 C CYLINDER WHPF BM USE AND MAINTENANCE HANDBOOK

IST 03 C CYLINDER WHPF BM USE AND MAINTENANCE HANDBOOK IST 03 C 185-01 CYLINDER WHPF BM USE AND MAINTENANCE HANDBOOK GB ES Dear Customer, Thank you for choosing our company and our hot water cylinder. Please read these instructions carefully. Cylinder correct

More information

Moisture inside the drum is due to final testing.

Moisture inside the drum is due to final testing. Safety instructions Scope of delivery depending on model Moisture inside the drum is due to final testing. Removing the transport safety devices Water connection depending on model The washing machine

More information

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model MICROGENUS PLUS. R EN - Edition 02-01/04/2007

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model MICROGENUS PLUS. R EN - Edition 02-01/04/2007 SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model MICROGENUS PLUS R8215343-02EN - Edition 02-01/04/2007 Domestic Gas Boilers MICROGENUS PLUS 537814 MICROGENUS PLUS 24 MET...... 3300078 MICROGENUS PLUS 21

More information

Metering systems 0548EN April 2014

Metering systems 0548EN April 2014 08EN April 0 0U8 GEY - Y - Y (GE- series) 900 000/ 00 00A/ 800 00L/ Versions and product codes Product code Type Heat exchanger nominal power GEY, - GEY and production GEY and production Table - Product

More information

Operating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents

Operating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents 1.0 Table of Contents 1.0 Table of Contents... 1........................................................................ 2 2.0 Functional description... 3 3.0 Safety notes... 4 3.1 Safety Notes general............................................

More information

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9 Contents Product Description 2 Approvals 2 Warranty 2 Warnings 2 Technical Specification 3 Installation 4 Location 4 Plumbing Connection 4 Electrical connection 5 Commissioning 6 Operation 6 Routine Preventative

More information

- 1- IMPORTANT SAFETY REMINDERS

- 1- IMPORTANT SAFETY REMINDERS USER MANUAL IMPORTANT SAFETY REMINDERS This appliance should only be used for domestic cleaning, as described in this user guide. Please ensure that this guide is fully understood before operating the

More information

Installation Instructions

Installation Instructions Installation Instructions The energy you need Accessories/PFGHRD 60/100 Passive Flue Gas Heat Recovery Device Explanation of Symbols a DANGER: Risk of injuries. The PFGHRD is an integral part of the flue

More information

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION 0 RD 0 RI 0000-06 IM/ IM/a INSTALLATION MANUAL This manual gives detailed advice for installation and should be read carefully prior to fitting

More information

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60 HG 675 X 60 HG 675 CX 60 HG 675 CN 60 HG 675 CW 60 1 2 1. : 93/68: 90/396: 2006/95/CE: 2004/108/CE: - 1935/2004:. 2002/95/CE: RoHS 2.,.,,,,...,. (,..)..,,.,. ( ),,, ;,,.,.....,.,,,,,,...,. (..),,.,..,.,,,,

More information

LINDOFLAMM thermal engineering.

LINDOFLAMM thermal engineering. Catalogue LINDOFLAMM thermal engineering. Tailored solutions for every heating application. 02 LINDOFLAMM thermal engineering. Tailored solutions for every heating application. Contents. 03 All-round offering

More information

Installation Guide. Termix Distribution unit. 1.0 Table of Contents. 1.0 Table of Contents

Installation Guide. Termix Distribution unit. 1.0 Table of Contents. 1.0 Table of Contents 1.0 Table of Contents 1.0 Table of Contents... 1........................................................................ 2 2.0 Functional description... 3 3.0 Safety notes... 4 3.1 Safety Notes general............................................

More information

Oblo Basin and Bidet Monobloc Installation and User Guide

Oblo Basin and Bidet Monobloc Installation and User Guide Oblo Basin and Bidet Monobloc Installation and User Guide MODEL NUMBERS 10085W-CP, 10088W-CP Important! Please quote the above model number(s) when ordering spares IMPORTANT Installer: This manual is the

More information

Installation Manual STOR C. Solar combination storage cylinder. Installation Manual

Installation Manual STOR C. Solar combination storage cylinder. Installation Manual Installation Manual STOR C Solar combination storage cylinder EN Installation Manual 2MANUALE INSTALLATORE Dear Installer, Thank you for choosing a BERETTA STOR C, combination storage cylinder. You have

More information

METRO BASIN MONO MIXER CHR

METRO BASIN MONO MIXER CHR METRO BASIN MONO MIXER CHR 20004010020 This product should only be fitted by a qualified plumber to NVQ (National Vocational Qualification) or SNVQ (Scottish National Vocational Qualification) Level 3.

More information

LYRA 1000 VVS Installation and Operation Manual LYRA 1000 VVS THERMAL STORE LYRA 1000 VVS

LYRA 1000 VVS Installation and Operation Manual LYRA 1000 VVS THERMAL STORE LYRA 1000 VVS www.regulus.eu LYRA 1000 VVS Installation and Operation Manual LYRA 1000 VVS THERMAL STORE EN LYRA 1000 VVS CONTENTS 1 Description... 3 1.1 Models... 3 1.2 Tank protection... 3 1.3 Thermal insulation...

More information

Accumulator tank. 1000, 750 and 500 litres Aqualux Teknik Aqualux UB Aqualux 750 CU

Accumulator tank. 1000, 750 and 500 litres Aqualux Teknik Aqualux UB Aqualux 750 CU Installation, operation and maintenance Accumulator tank 1000, 750 and 500 litres Aqualux Teknik Aqualux B Aqualux 750 C Aqualux 750 Teknik with bivalent shunt, optional extra 2012-02-08 ver.: Supersedes:

More information

PARTS BOOK. From S/N:

PARTS BOOK. From S/N: PARTS BOOK From S/N: 4486 All spares available from The Engine Shed Top Station Road Brackley NN UG Tel: 084 08060 Fax: 080 844 Web: www.caterparts.com Copyright Notice: All rights reserved. No parts of

More information

EXTREME HP-1 Reverse Osmosis System

EXTREME HP-1 Reverse Osmosis System EXTREME HP-1 Reverse Osmosis System Leader Evaporator Co., Inc. 49 Jonergin Drive Swanton, VT 05488 Tel: 802-868-5444 www.leaderevaporator.com TABLE OF CONTENTS INTRODUCTION... 4 THEORY OF OPERATION...

More information

M07. Wunda Premium Manifold. Before you start: Check the contents THE BRAND YOU CAN TRUST

M07. Wunda Premium Manifold. Before you start:  Check the contents THE BRAND YOU CAN TRUST Before you start: Check the manifold box contents against the list below. Check the contents 1. 2 x Manifold end blanks 2. 2 x Manual air vent & drain cocks 3. 2x Adjustable mounting brackets 4. Manifold

More information

Vivadens. Wall-hung gas condensing boilers MCR 24/28 BIC. User Guide B

Vivadens. Wall-hung gas condensing boilers MCR 24/28 BIC. User Guide B Vivadens EN Wall-hung gas condensing boilers MCR 24/28 BIC User Guide 300024112-001-B Contents 1 Introduction...4 1.1 Symbols used...4 1.2 Abbreviations...4 1.3 General...4 1.3.1 Manufacturer's liability...4

More information

R146C. Adjustable magnetic dirt separator. Versions and product codes. Datasheet 0840EN 10/2018

R146C. Adjustable magnetic dirt separator. Versions and product codes. Datasheet 0840EN 10/2018 R146C Adjustable magnetic dirt separator Datasheet 0840EN 10/2018 The R146C adjustable magnetic dirt separator separates and removes debris inside hydraulic circuits of modern heating and cooling systems.

More information

High-efficiency circulating pumps Heating Air conditioning 50 Hz

High-efficiency circulating pumps Heating Air conditioning 50 Hz OPERATING RANGE Flow rate of up to m /h Manometric head of up to 8 mwc Max. operating pressure bar Min. suction pressure, bar at 9 C Temperature range - C at 9 C Max. ambient temperature + C EEI-Part,

More information

INISOL EASYLIFE. SOLAR COLLECTORS, TANKS AND SYSTEMS for domestic installations

INISOL EASYLIFE. SOLAR COLLECTORS, TANKS AND SYSTEMS for domestic installations INIOL OLAR COLLECTOR, TANK AND YTEM for domestic installations INIOL NEO solar collector and fields of solar collectors INIOL UNO/1 and UNO/2 solar tanks for the production of domestic hot water (200 to

More information

ZENA PLUS EASYLIFE WALL-HUNG GAS BOILERS

ZENA PLUS EASYLIFE WALL-HUNG GAS BOILERS ZENA PLUS WALL-HUNG GAS BOILERS MSL FF: from. to 1 kw for heating only MSL FF + BMR 80 and MSL FF + SR 10: from. to 1 kw for heating and DHW produced by an 80-litre calorifier placed beside the boiler,

More information

Remeha. Fuel oil/gas boilers P 320. Installation and Service Manual

Remeha. Fuel oil/gas boilers P 320. Installation and Service Manual Remeha Fuel oil/gas boilers P 320 en Installation and Service Manual 300016243-02 Declaration of conformity The appliance complies with the standard model described in declaration of compliance. It is

More information

DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe

DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe Copyright 206 Caleffi NA0322.02 www.caleffi.com NA5453 Series Installation, commissioning and servicing instructions Function

More information

RADIANT PANEL SYSTEM CONTROL QUICK GUIDE

RADIANT PANEL SYSTEM CONTROL QUICK GUIDE RADIANT PANEL CONTROL QUICK GUIDE 05 RADIANT PANEL CONTROL Terms and definitions The system temperature regulation can be carried out in only two basic ways: Flow rate control of the medium feeding the

More information

Telo Shower Mixing Valve TL10016CP

Telo Shower Mixing Valve TL10016CP Telo Shower Mixing Valve TL10016CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept any responsibility

More information

APPLICATIONS. For the accelerated circulation of hot water in heating circuits with duty point optimisation

APPLICATIONS. For the accelerated circulation of hot water in heating circuits with duty point optimisation OPERATING RANGE Flow rate of up to m /h Manometric head of up to m Max. operating pressure bar Min. intake pressure, bar at 9 C Water temperature range + at + C * EEI-Part, * for a ambient temperature

More information

4FLOOR-STANDING GAS CONDENSING BOILERS

4FLOOR-STANDING GAS CONDENSING BOILERS EASYLIFE PROJECT / SOLNEO / ECODENS RESIDENTIAL DTG (E) 130-15/25 Eco. NOx Plus DTG (E) 1300-15/25 Eco. NOx Plus/B150 DTG (E) 1300-15/25 Eco. NOx Plus/H150 DTG 1300-15/25 Eco. NOx Plus/V130 4FLOOR-STANDING

More information

Commissioning a Solar Thermal Installation

Commissioning a Solar Thermal Installation OPERATING INSTRUCTIONS Wagner& Co Commissioning a Solar Thermal Installation Contents. Solar Circuit... 2. Commissioning... 3 3. Service Information... 4. Maintenance.... Solar Circuit Components Pipework

More information

VIESMANN. Installation and service instructions. Solar-Divicon SR. Safety instructions. Application. for contractors. Part no and

VIESMANN. Installation and service instructions. Solar-Divicon SR. Safety instructions. Application. for contractors. Part no and Installation and service instructions for contractors VIESMANN Solar-Divicon SR Part no. 7419 520 and 7419 521 Safety instructions Please follow these safety instructions closely to prevent accidents and

More information

Condair Esco. Steam humidification system INSTALLATION INSTRUCTIONS EN 1310

Condair Esco. Steam humidification system INSTALLATION INSTRUCTIONS EN 1310 Condair Esco Steam humidification system L INSTALLATION INSTRUCTIONS 1117775 EN 1310 3 Contents 1 Introduction 4 1.1 General 4 1.2 Safety 4 2 Esco DL40 5 2.1 Overview Esco DL40 5 2.2 Mounting the Esco

More information

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE SPECIFICATIONS... 1 OVERVIEW... 2 PRECAUTIONS... 2 MOUNTING LOCATION... 2 CONNECTION TO BOILER PRIMARY PIPING:... 3 ELECTRICAL CONNECTION... 4 FLUSHING THE

More information

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20 INSTALLATION, OPERATION AND MAINTENANCE Ariterm Hybrid 20 TABLE OF CONTENTS General...3 Installation... 4-5 Dimensions - with flue gas exhauster...6 Dimensions - without flue gas exhauster...7 Pipe installations...8

More information

EXTREME 2 Reverse Osmosis System

EXTREME 2 Reverse Osmosis System EXTREME 2 Reverse Osmosis System Leader Evaporator Co., Inc. 49 Jonergin Drive Swanton, VT 05488 Tel: 802-868-5444 www.leaderevaporator.com TABLE OF CONTENTS INTRODUCTION... 4 THEORY OF OPERATION... 4

More information

Spectrum TM. Installation, Service & Operation Manual O FLO. SoftH 2. Water Softener. Table of Contents

Spectrum TM. Installation, Service & Operation Manual O FLO. SoftH 2. Water Softener. Table of Contents Installation, Service & Operation Manual SoftH 2 O FLO Water Softener Table of Contents 1. Description & Equipment Adjustments p.2 2. Components, Features & Functions p.3 3. Valve User Interface p.4 4.

More information

Operating instructions

Operating instructions BA60500GB.docx, Operating instructions -Translation of the original- Dirt Collecting Filter DIN m/m M&S Article No. 60500 M & S Armaturen GmbH Industriestraße 24-26 - 26446 Friedeburg - Germany fon +49(0)4465

More information

Cold water HD 9/18-4 ST

Cold water HD 9/18-4 ST Cold water HD 9/18-4 ST The space-saving stationary high-pressure cleaners from Kärcher with up to 6 supply points can be individually configured according to requirements and impress with low wear and

More information

T E C H C A L EBS-1 T High technology heating

T E C H C A L EBS-1 T High technology heating IMPORTANT FOLLOW COMMISSIONING INSTRUCTIONS OBSERVE THE WARRANTY CONDITIONS READ THE WHOLE MANUAL CAREFULLY NO SAFETY DISCHARGE TO BE REDUCED IN SIZE. CONDENSE TO BE 32 mm PVC T E C H NI C A L I N ST EBS-1

More information

Beautifully Traditional

Beautifully Traditional TECHNICAL DETAILS For full technical details on all our products, please visit our website Arcade bath shower mixer - deck mounted with brass handle handset Arcade bath shower mixer - wall mounted with

More information

VAILLANT SPARE PART CATALOGUE

VAILLANT SPARE PART CATALOGUE VAILLANT SPARE PART CATALOGUE Vaillant unvented indirect hot water cylinder VANTAGE VIHC120 VANTAGE 120 VANTAGE 150, 200 Vaillant gas fired storage water heater VGH 130/1, 160/1, 190/1 VGH 130/2, 160/2,

More information

DTG Eco / V130

DTG Eco / V130 ECODENS Gas fired condensing boiler EN User Guide 300010111-001-B Contents 1 Introduction.............................................................................3 1.1 Symbols and abbreviations................................................................................3

More information

STREBEL S-CB + Cascade Kits

STREBEL S-CB + Cascade Kits STREBEL S-CB + Cascade Kits Models + 60 - + 80 - + 100 - + 120 PX 120 - + 10 - + 180 Installation & Operating Manual 2x60 up to 12x180 Please read and understand before commencing installation and leave

More information

HR Powder Feed Hopper

HR Powder Feed Hopper Instruction Sheet P/N 106977E0 Description This instruction sheet provides specifications; installation and operation instructions; and parts lists for the HR-16-150 powder feed hopper. The hopper is shipped

More information

VIESMANN. Installation instructions VITOCELL 300-V/W. for contractors. Vitocell 300-V/W Type EVIA-A

VIESMANN. Installation instructions VITOCELL 300-V/W. for contractors. Vitocell 300-V/W Type EVIA-A Installation instructions for contractors VIESMNN Vitocell 300-V/W Type EVI- DHW cylinder with internal indirect coil 160 to 500 l VITOCELL 300-V/W 3/2017 Dispose after installation. Safety instructions

More information

Installation Manual. Conergy TS Open and Closed Systems.

Installation Manual. Conergy TS Open and Closed Systems. Installation Manual Conergy TS Open and Closed Systems www.conergy.com.au Table of Contents Table of Contents 1 1.1 Installer Information The environmental benefits 2 2 1.2 Why Conergy? 2 1.3 How does

More information

Installation, commissioning and servicing instructions

Installation, commissioning and servicing instructions NA10322.01 www.caleffi.com DIRTMAG dirt separator Copyright 2015 Caleffi NA5453 Series Installation, commissioning and servicing instructions Function In heating and chilled water systems, the circulation

More information

VERTINOX. AISI 316 stainless steel accumulators with one or two heat exchangers, fixed or removable type

VERTINOX. AISI 316 stainless steel accumulators with one or two heat exchangers, fixed or removable type 27-0514 VERTINOX AISI 316 stainless steel accumulators with one or two heat exchangers, fixed or removable type VERTINOX: THE RELIABLE HEART The boiler for hot sanitary water production is the heart of

More information

Lago SD3. Differential Controller with Speed Control. Operating and Installation Instructions

Lago SD3. Differential Controller with Speed Control. Operating and Installation Instructions Lago SD3 Differential Controller with Speed Control Operating and Installation Instructions Please observe the safety instructions and read through this manual carefully before commissioning the equipment.

More information

AD XT. Air Dryer Service Manual. Innovation with Integrity. Version 003 NMR

AD XT. Air Dryer Service Manual. Innovation with Integrity. Version 003 NMR AD XT Air Dryer Service Manual Version 003 Innovation with Integrity NMR Copyright by Bruker Corporation All rights reserved. No part of this publication may be reproduced, stored in a retrieval system,

More information

Instruction Manual. Automatic fuel oil de-aerator SMART-FLO 3/K B100 COMPATIBLE

Instruction Manual. Automatic fuel oil de-aerator SMART-FLO 3/K B100 COMPATIBLE Sid Harvey s 605 Locust Street Garden City, NY 11530 Instruction Manual Automatic fuel oil de-aerator SMART-FLO 3/K Read manual before use! Observe all safety information! Keep manual for future use! 05.2015

More information

Thermostatic Concealed Shower Valve

Thermostatic Concealed Shower Valve Thermostatic Concealed Shower Valve Product may differ from image. Please retain this booklet for future aftercare reference Component Breakdown - Three Handle Valve Component breakdown Two Handle Valve

More information

Pump assembly Instruction manual

Pump assembly Instruction manual Instruction manual EN Version 2.0 /Release 06/2012 Table of content 1 Key background information...3 1.1 Limitation of liability...3 1.2 Responsibilities of the operator...3 1.3 Documentation...3 1.3.1

More information

Installation, operation and maintenance. Accumulator tank. Acc-tank 500 CU. Acc-tank 500 UB ver: Supersedes:

Installation, operation and maintenance. Accumulator tank. Acc-tank 500 CU. Acc-tank 500 UB ver: Supersedes: Installation, operation and maintenance Accumulator tank Acc-tank 500 CU 2010-11-2 ver: Supersedes: Acc-tank General information 1011 Read through these instructions carefully before carrying out installation,

More information

EXTREME 4 Reverse Osmosis System

EXTREME 4 Reverse Osmosis System EXTREME 4 Reverse Osmosis System Leader Evaporator Co., Inc. 49 Jonergin Drive Swanton, VT 05488 Tel: 802-868-5444 www.leaderevaporator.com TABLE OF CONTENTS INTRODUCTION... 4 THEORY OF OPERATION... 4

More information

Flat Plate Solar Collector

Flat Plate Solar Collector Flat Plate Solar Collector Installation, commissioning and maintenance instructions Models: LSP20+ LSP20+H installation manual_flat plate collector_augus t2017 Page 0 CONTENTS 0 1 INTRODUCTION... 3 1.1

More information

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler HIGH POWER VICTRIX PRO 2 ErP High power, wall-hung condensation boiler MAIN INDEX INDEX 1 VICTRIX PRO 35-55 2 ErP SPECIFICATIONS...5 2 VICTRIX PRO 80-100-120 2 ErP SPECIFICATIONS...6 3 VICTRIX PRO 35-55

More information

PARTS BOOK. From S/N:

PARTS BOOK. From S/N: PARTS BOOK From S/N: 2786017 All spares available from The Engine Shed Top Station Road Brackley NN1 7UG Tel: 0845 108060 Fax: 01280 84545 Web: www.caterparts.com Copyright Notice: All rights reserved.

More information

Brazed heat exchanger XB

Brazed heat exchanger XB Description The XB is a range of copper brazed plate heat exchangers for use in District Heating (DH) and District Cooling (DC) applications, e.g. domestic hot water production, district heating substation

More information