Circulation pumps. Wet rotor circulators and accessories. Heating Potable water Solar Geothermy Condensate
|
|
- Dulcie Hill
- 6 years ago
- Views:
Transcription
1 Circulation pumps Wet rotor circulators and accessories eating Potable water Solar Geothermy Condensate CATALOGUE /
2 alm produces highly-efficient heating circulation pumps alm has been successfully developing and producing heating circulation pumps for over years. It started out manufacturing for renowned OEM customers before electing to develop and produce its own product range in the late s. Its proficiency in the development of innovative, market-oriented products is first and foremost reflected in the more than half a century of company history. Today, in the third generation, the circulation pumps segment plays a major part in the success of the company. This is particularly evident in the high level of creative innovation in recent years, with many new products in the field of high-efficiency pumps. alm places great demand on the quality of its products Modern production facilities and processes are just as much part of the corporate concept as well thought-out quality management. Internal testing facilities and ISO-certified quality management are indispensible factors of success. Long-standing customers value the high demands placed on the quality of the products and the flexibility with which alm meets custom requirements. alm is helping to shape the future as a reliable partner A company is only as good as each of its constituent parts. This is why motivated and experienced employees are a key element of success at alm. Flexibility and expertise head the list of priorities for being a reliable partner to our customers. Together with over employees, alm s objective is to make a lasting contribution to the future with its products. alm high efficiency pumps already fulfil the tightened requirements of the eco-design directive from until. The new EP Optimo features an LED display showing the modes of operation, the pressure head, the total electrical input power as well as error codes. As standard, it is delivered with a plug and with installation length mm also the insulation shell is included in delivery. No insulation shell is offered for mm installation length. For the EP Optimo Basic version, we ommit features such as display, insulation shell and plug but we fit a premounted cable in order to be able to offer a very well-priced model for different applications for which these features are neither required nor necessary. UPA UE EP EP Plus EP Plus (N) EP BB EP-L + EP Optimo
3 Catalogue valid for EU countries + others ) I. Product range Page Contact General information eating EP Optimo: igh efficiency pumps with LED display, electronically controlled EP Optimo Basic: igh efficiency pumps, electronically controlled EP Optimo L: igh efficiency pumps with LCD display, electronically controlled Potable water EP Optimo (N): igh efficiency pumps with LED display and stainless steel housing, electronically controlled EP Optimo Basic (N): igh efficiency pumps with stainless steel housing, electronically controlled BUPA (N): Standard circulation pumps for potable water with stainless steel housing BGPA (N): Circulation pumps for potable water, with stainless steel housing, pressure head - m Solar EP Optimo Solar: igh efficiency pumps with LED display, electronically controlled EP Optimo L Solar: igh efficiency pumps with LCD display, electronically controlled EP BB: Babelbox BB and EP PWM Geothermy EP Optimo Geo: igh efficiency pumps with LED display, electronically controlled and protected against condensation EP Optimo L Geo: igh efficiency pumps with LCD display, electronically controlled and protected against condensation Condensate Lift: Condensate pump for gas condensing boilers up to kw Lift Basic: Condensate pump for gas condensing boilers up to kw Lift NT: Condensate pump for oil condensing boilers with neutralization tank Accessories Screw connections Plug Insulation shell Accessories/Spare parts ) EFTA (Iceland, Liechtenstein, Norway), Croatia, Switzerland, autonomic areas of EU member states (Faroe Islands, Jersey, Isle of Man, Guernsey, Greenland), Andorra, Monaco, San Marino. Subject to technical changes without notice. Errors and ommissions excepted. The latest versions of our sales, delivery, and payment conditions as well as guarantee terms can be found on the internet at
4 Contact at alm: Sales Mr Robin Pomreinke Phone: + - Fax: + - Order Management Ms Sabrina Wagner sabrina.wagner@halm.info Phone: + - Fax: + After Sales Mr Jürgen Albrecht juergen.albrecht@halm.info Phone: + - Fax: + - Mr Thomas Müller thomas.mueller@halm.info Phone: + - Fax: + Service hotline Phone: + -
5 General information alm type key EP Optimo -. G Pump types Nominal width pipe connection Pressure head in meters water column Speed switchable or electronically controlled Installation length (mm) Installation options Circulation pumps must be installed with a horizontal shaft. Construction alm circulation pumps are inline wet rotor circulators. They are maintenance-free and fitted with opposite-facing connecting nozzles of the same nominal width. The pump, motor and terminal box comprise one unit and are optimally matched with one another. A stainless steel can separates the rotor chamber and stator winding. It features static seals at both ends. Bearing Both bearings are made of oxide ceramic. This is particularly suitable because of its hardness, surface quality and corrosion resistance. They ensure smooth running and a long service life. Air cavities in the can well are evacuated via the hollow shaft. EEI The benchmark of the most efficient circulators is EEI.. All alm m high efficiency pumps fulfill the requirements for BEST in class.
6 igh efficiency pumps with LED display, electronically controlled EP Optimo series, product group Insulation shell With installation length mm included in delivery. valid for all alm m igh efficiency pumps Flow media heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm²/s operating data must be checked above % glycol Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: + C to + C Rate of flow: up to. m /h Pressure head: m/ m/ m Control range: - W/- W/- W Media temperature: + C to + C Installation length: and mm Threaded connection:, ½ and Protection class: IP Insulation class: F Nominal pressure: PN Control: pc + pv + fixed rpm EEI:. EP Optimo XX-. GXXX. EP Optimo XX-. GXXX. EP Optimo XX-. GXXX Product features manual start-up feature smooth running very low energy consumption integrated night economy feature air-vent screw LED display convenient operation + space-saving axially integrated terminal box automatic adjustment to pressure conditions cataphorectic coated pump housing pre-mounted, screwable angle entry-plug compact design Use The electronically controlled EP Optimo high efficiency wet rotor circulators with LED display and permanent magnet technology are designed for use in heating systems with variable or constant rate of flow. The cataphoretic coated pump housing is stainless. Mode of operation p control When thermostatic valves in systems with a long main supply heating pipe (likely for radiator systems) close, the total flow drops. This results in lower pipe resistance in this main pipe, which means the pump has to create lower head. Using proportional pressure mode PP ( ) is the best setting for such heating systems, as here the pump decreases head at lower flow. If the main supply heating pipe has not to be taken into consideration, because it is short or has its own pump (likely for underfloor heating systems with in mixing units integrated pumps), best mode to go with is constant pressure mode CP ( ). In such heating systems, it is important always to have constant pressure for the radiators or ufh-circuits, as the pressure loss in the main pipe is not considered and all other consumers are installed in parallel, which does not influence the maximum pressure loss. Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Integrated night economy feature When the automatic night economy feature is activated, the circulation pump switches between normal mode and economy mode (characteristic curve MIN). The flow temperature is detected by a temperature sensor, the pump reacts accordingly. For this, it is necessary for the circulation pump to be installed in flow. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < C > C Minimum inflow pressure. bar. bar Sound pressure level The sound pressure level is < db (A) Choice of control characteristic You can set different control modes via the potentiometer on the axial terminal box. Proportional pressure ( ), fixed speed ( ) and constant pressure ( ) can be adjusted continuously variable. The display indicates power consumption in [W] watts. Once the potentiometer is turned, the display first indicates mode of operation (PP, SC, CP), then value of set head in [m] meters. At the factory setting the potentiometer is in mode PP. Main areas of use eating, air-conditioning and industry systems as dual pipe system underfloor heating boiler/primary circuit storage charging circuit solar systems and heating pumps Materials Component Material Material no. Pump housing Grey-cast iron. Impeller Polyamide (PA - GF ) Shaft Bearing Bearing plate Stainless steel. Can Stainless steel.
7 igh efficiency pumps with LED display, electronically controlled EP Optimo series, product group Type Connection pipe Threaded connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. EEI EP Optimo -. G ½ EP Optimo -. G ½ EP Optimo -. G ½ EP Optimo -. G ¼ EP Optimo -. G ¼ EP Optimo -. G ¼ EP Optimo -. G ½ EP Optimo -. G ½ EP Optimo -. G ½ EP Optimo -. G ¾ ¼ EP Optimo -. G ¾ ¼ EP Optimo -. G ¾ ¼ EP Optimo -. G ½ EP Optimo -. G ½ EP Optimo -. G ½ Constant pressure EP Optimo...-.-G Q (m / h) EP Optimo...-.-G Q (m / h) EP Optimo...-.-G Q (m³ / h) Proportional pressure EP Optimo...-.-G Q (m / h) EP Optimo...-.-G Q (m / h) EP Optimo...-.-G Q (m³ / h) Fixed rpm EP Optimo...-.-G Q (m / h) EP Optimo...-.-G Q (m / h) EP Optimo...-.-G Q (m³ / h) Dimensions Dimension illustration G Type L L L L EP Optimo / L L L L
8 igh efficiency pumps, electronically controlled EP Optimo Basic series, product group valid for all alm m igh efficiency pumps + Flow media heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm²/s operating data must be checked above % glycol Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: + C to + C Rate of flow: up to. m /h Pressure head: m/ m/ m Control range: - W/- W/ - W Media temperature: + C to + C Installation length: and mm Threaded connection:, ½ and Protection class: IP Insulation class: F Nominal pressure: PN Control: pc + pv + fixed rpm EEI:. EP Optimo Basic XX-. GXXX. EP Optimo Basic XX-. GXXX. EP Optimo Basic XX-. GXXX Product features manual start-up feature smooth running very low energy consumption integrated night economy feature air-vent screw convenient operation space-saving axially integrated terminal box automatic adjustment to pressure conditions cataphorectic coated pump housing pre-mounted cable ( m) compact design Use The electronically controlled EP Optimo Basic high efficiency wet rotor circulators with permanent magnet technology are designed for use in heating systems with variable or constant rate of flow. Mode of operation p control When thermostatic valves in systems with a long main supply heating pipe (likely for radiator systems) close, the total flow drops. This results in lower pipe resistance in this main pipe, which means the pump has to create lower head. Using proportional pressure mode PP ( ) is the best setting for such heating systems, as here the pump decreases head at lower flow. If the main supply heating pipe has not to be taken into consideration, because it is short or has its own pump (likely for underfloor heating systems with in mixing units integrated pumps), best mode to go with is constant pressure mode CP ( ). In such heating systems, it is important always to have constant pressure for the radiators or ufh-circuits, as the pressure loss in the main pipe is not considered and all other consumers are installed in parallel, which does not influence the maximum pressure loss. Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Integrated night economy feature When the automatic night economy feature is activated, the circulation pump switches between normal mode and economy mode (characteristic curve MIN). The flow temperature is detected by a temperature sensor, the pump reacts accordingly. For this, it is necessary for the circulation pump to be installed in flow. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < C > C Minimum inflow pressure. bar. bar Sound pressure level The sound pressure level is < db (A) Choice of control characteristic You can set different control modes via the potentiometer on the axial terminal box. Proportional pressure ( ), fixed speed ( ) and constant pressure ( ) can be adjusted continuously variable. Main areas of use eating, air-conditioning and industry systems as dual pipe system underfloor heating boiler/primary circuit storage charging circuit solar systems and heating pumps Materials Component Material Material no. Pump housing Grey-cast iron. Impeller Polyamide (PA - GF ) Shaft Bearing Bearing plate Stainless steel. Can Stainless steel.
9 igh efficiency pumps, electronically controlled Serie EP Optimo Basic, product group Type Connection pipe Threaded connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. EEI EP Optimo Basic -. G ½ EP Optimo Basic -. G ½ EP Optimo Basic -. G ½ EP Optimo Basic -. G ¼ EP Optimo Basic -. G ¼ EP Optimo Basic -. G ¼ EP Optimo Basic -. G ½ EP Optimo Basic -. G ½ EP Optimo Basic -. G ½ EP Optimo Basic -. G ¾ ¼ EP Optimo Basic -. G ¾ ¼ EP Optimo Basic -. G ¾ ¼ EP Optimo Basic -. G ½ EP Optimo Basic -. G ½ EP Optimo Basic -. G ½ Constant pressure EP Optimo Basic...-.-G Q (m / h) EP Optimo Basic...-.-G Q (m / h)... EP Optimo Basic...-.-G.... Q (m³ / h) Proportional pressure.. EP Optimo Basic...-.-G Q (m / h) EP Optimo Basic...-.-G Q (m / h) EP Optimo Basic...-.-G Q (m³ / h) Fixed rpm..... EP Optimo Basic...-.-G Q (m / h) EP Optimo Basic...-.-G Q (m / h) EP Optimo Basic...-.-G Q (m³ / h) Dimensions Dimension illustration G Type L L L L EP Optimo Basic / L L L L
10 igh efficiency pumps with LCD display, electronically controlled EP Optimo L series, product group Insulation shell included in delivery. + Rate of flow: up to m /h Pressure head: m/ m Control range: - W/- W Media temperature: + C to + C Installation length: mm (thread)/ mm (flange) Threaded connection: ½ and (thread)/dn and DN (flange) Protection class: IP Insulation class: F Nominal pressure: PN EEI:. EP Optimo L XX-. G. EP Optimo L XX-. G Control: Internal: External: pc + pv + fixed rpm digital: PWM (characteristic lines for heating and solar per VDMA device paper ) frequency f nominal: - z voltage U nominal: - V power I: ma analogue: - V with cable break detection power I: ma impedance: kohm Omnibus fault message: Selector switch, potential-free, power max. A/ VAC Power supply for external unit: Voltage DC V, power max. ma Product features LCD display manual start-up feature smooth running very low energy consumption air-vent screw collective fault signal convenient operation axially integrated terminal box automatic adjustment to pressure conditions cataphoretic coated pump housing Use The electronically controlled EP Optimo L high efficiency wet rotor circulators with LCD display and permanent magnet technology are designed for use in heating systems with variable or constant rate of flow. The cataphoretic coated pump housing is stainless. Main areas of use eating, air-conditioning and industry systems as dual pipe system single pipe system underfloor heating boiler/primary circuit storage charging circuit solar systems and heating pumps Materials Component Material Material No. Pump body Grey-cast iron. Impeller Polyamide (PA - GF ) Shaft Bearing Bearing plate Stainless steel. Can Stainless steel. Flow media heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm²/s operating data must be checked above % glycol Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: + C to + C Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < C > C Minimum inflow pressure. bar. bar Controls function You can make adjustments with the integrated control keys at the front. The LCD display shows the total electrical input power as a numeric value in [W] watts. Different icons at the top of the display show the function, setting and the modes of operation. Sound pressure level The sound pressure level is < db (A)
11 igh efficiency pumps with LCD display, electronically controlled EP Optimo L series, product group Type Connection pipe Threaded connection Flange Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. EEI EP Optimo L -. G ½ EP Optimo L -. G ½ EP Optimo L -. G ¼ EP Optimo L -. G ¼ EP Optimo L -. G - - DN EP Optimo L -. G - - DN EP Optimo L -. G - - DN EP Optimo L -. G - - DN Proportional pressure Constant pressure Fixed rpm EP Optimo L...-. G EP Optimo L...-. G EP Optimo L...-. G step step step LOW LOW Q (m / h) Q (m / h) Q (m / h) Proportional pressure Constant pressure Fixed rpm EP Optimo L...-. G EP Optimo L...-. G step EP Optimo L...-. G step step LOW LOW Q (m / h) Q (m / h) Q (m / h) Dimensions Type L L L L EP Optimo L (thread) EP Optimo L (flange). Dimension illustration L L L L A
12 igh efficiency pumps with LED display and stainless steel housing, electronically controlled EP Optimo (N) series, T product group Insulation shell With installation length mm included in delivery. valid for all alm m igh efficiency pumps Flow media potable water and heated potable water to a temperature of C and a degree of hardness of d (temporary hardness) heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm²/s operating data must be checked above % glycol Rate of flow: up to. m /h Pressure head: m/ m Control range: - W/- W Media temperature: + C to + C Installation length:, and mm Threaded connection:, ½ and Protection class: IP Insulation class: F Nominal pressure: PN Control: pc + pv + fixed rpm EEI:. EP Optimo XX-. NXXX. EP Optimo XX-. NXXX Product features manual start-up feature smooth running very low energy consumption integrated night economy feature air-vent screw LED display convenient operation space-saving axially integrated terminal box + automatic adjustment to pressure conditions stainless steel pump housing pre-mounted, screwable angle entry-plug compact design optical fault indication optical display control mode Use The electronically controlled EP Optimo (N) high efficiency wet rotor circulators with LED display and permanent magnet technology are designed for use in heating systems as well as potable water systems with variable or constant rate of flow. Mode of operation p control When thermostatic valves in systems with a long main supply heating pipe (likely for radiator systems) close, the total flow drops. This results in lower pipe resistance in this main pipe, which means the pump has to create lower head. Using proportional pressure mode PP ( ) is the best setting for such heating systems, as here the pump decreases head at lower flow. If the main supply heating pipe has not to be taken into consideration, because it is short or has its own pump (likely for underfloor heating systems with in mixing units integrated pumps or potable water systems), best mode to go with is constant pressure mode CP ( ). In such heating systems, it is important always to have constant pressure for the radiators or ufh-circuits, as the pressure loss in the main pipe is not considered and all other consumers are installed in parallel, which does not influence the maximum pressure loss. Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: + C to + C Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Integrated night economy feature When the automatic night economy feature is activated, the circulation pump switches between normal mode and economy mode (characteristic curve MIN). The flow temperature is detected by a temperature sensor, the pump reacts accordingly. For this, it is necessary for the circulation pump to be installed in flow. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < C > C Minimum inflow pressure. bar. bar Sound pressure level The sound pressure level is < db (A) Choice of control characteristic You can set different control modes via the potentiometer on the axial terminal box. Proportional pressure ( ), fixed speed ( ) and constant pressure ( ) can be adjusted continuously variable. The display indicates power consumption in [W] watts. Once the potentiometer is turned, the display first indicates mode of operation (PP, SC, CP), then value of set head in [m] meters. At the factory setting the potentiometer is in mode PP. Main areas of use potable water systems Materials Component Material Material no. Pump housing Stainless steel. Impeller Polyamide (PA - GF ) Shaft Bearing Bearing plate Stainless steel. Can Stainless steel.
13 igh efficiency pumps with LED display and stainless steel housing, electronically controlled EP Optimo (N) series, T product group Type Connection pipe Threaded connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. EEI EP Optimo -. N ½ EP Optimo -. N ½ EP Optimo -. N ½ EP Optimo -. N ½ EP Optimo -. N ¾ ¼ EP Optimo -. N ¾ ¼ EP Optimo -. N ½ EP Optimo -. N ½ Constant pressure EP Optimo...-.-N Q (m / h) EP Optimo...-.-N Q (m / h) Proportional pressure EP Optimo...-.-N Q (m / h) EP Optimo...-.-N Q (m / h) Fixed rpm EP Optimo...-.-N Q (m / h) EP Optimo...-.-N Q (m / h) Dimensions Type L L L L EP Optimo (N) // Dimension illustration G L L L L
14 igh efficiency pumps with stainless steel housing, electronically controlled EP Optimo Basic (N) series, T product group Rate of flow: up to. m /h Pressure head: m/ m Control range: - W/- W Media temperature: + C to + C Installation length:, and mm Threaded connection:, ½ and Protection class: IP Insulation class: F Nominal pressure: PN Control: pc + pv + fixed rpm EEI:. EP Optimo Basic XX-. NXXX. EP Optimo Basic XX-. NXXX Product features manual start-up feature smooth running very low energy consumption integrated night economy feature air-vent screw convenient operation valid for all alm m igh efficiency pumps + space-saving axially integrated terminal box automatic adjustment to pressure conditions stainless steel pump housing pre-mounted cable ( m) compact design Use The electronically controlled EP Optimo Basic (N) high efficiency wet rotor circulators with permanent magnet technology are designed for use in heating systems as well as potable water systems with variable or constant rate of flow. Mode of operation p control When thermostatic valves in systems with a long main supply heating pipe (likely for radiator systems) close, the total flow drops. This results in lower pipe resistance in this main pipe, which means the pump has to create lower head. Using proportional pressure mode PP ( ) is the best setting for such heating systems, as here the pump decreases head at lower flow. If the main supply heating pipe has not to be taken into consideration, because it is short or has its own pump (likely for underfloor heating systems with in mixing units integrated pumps or potable water systems), best mode to go with is constant pressure mode CP ( ). In such heating systems, it is important always to have constant pressure for the radiators or ufh-circuits, as the pressure loss in the main pipe is not considered and all other consumers are installed in parallel, which does not influence the maximum pressure loss. Flow media potable water and heated potable water to a temperature of C and a degree of hardness of d (temporary hardness) heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm²/s operating data must be checked above % glycol Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: + C to + C Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Integrated night economy feature When the automatic night economy feature is activated, the circulation pump switches between normal mode and economy mode (characteristic curve MIN). The flow temperature is detected by a temperature sensor, the pump reacts accordingly. For this, it is necessary for the circulation pump to be installed in flow. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < C > C Minimum inflow pressure. bar. bar Sound pressure level The sound pressure level is < db (A) Choice of control characteristic You can set different control modes via the potentiometer on the axial terminal box. Proportional pressure ( ), fixed speed ( ) and constant pressure ( ) can be adjusted continuously variable. Main areas of use potable water systems Materials Component Material Material no. Pump housing Stainless steel. Impeller Polyamide (PA - GF ) Shaft Bearing Bearing plate Stainless steel. Can Stainless steel.
15 igh efficiency pumps with stainless steel housing, electronically controlled EP Optimo Basic (N) series, T product group Type Connection pipe Threaded connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. EEI EP Optimo Basic -. N ½ EP Optimo Basic -. N ½ EP Optimo Basic -. N ½ EP Optimo Basic -. N ½ EP Optimo Basic -. N ¾ ¼ EP Optimo Basic -. N ¾ ¼ EP Optimo Basic -. N ½ EP Optimo Basic -. N ½ Constant pressure EP Optimo Basic...-.-N Q (m / h) EP Optimo Basic...-.-N Q (m / h) Proportional pressure EP Optimo Basic...-.-N Q (m / h) EP Optimo Basic...-.-N Q (m / h) Fixed rpm EP Optimo Basic...-.-N Q (m / h) EP Optimo Basic...-.-G Q (m / h) Dimensions Type L L L L EP Optimo Basic (N) / Dimension illustration G L L L L
16 Standard circulation pumps for potable water with stainless steel housing BUPA (N) series, T product group Rate of flow: up to. m / h Pressure head: up to m Media temperature: + C to + C Installation length:, and mm Threaded connection:, ¼ and ½ Protection class: IP Insulation class: Nominal pressure: PN Control: -step switch with manual speed selection Product features manual start-up feature space-saving axially integrated terminal box Use The BUPA (N) series circulation pumps are wet rotor circulators designed for use in potable water systems with constant or weakly variable flow rates. They feature a corrosion-resistant pump housing in stainless steel and are thus suitable for use in potable water circulation systems. Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Materials Component Material Material no. Pump housing Stainless steel. Impeller PSU - GF Speed switching The respective speed is set via a rotary switch integrated in the axial terminal box. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Shaft Bearing Bearing plate Stainless steel. Media temperature < C C C Minimum inflow pressure. bar. bar. bar Can Stainless steel. Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: + C to + C Sound pressure level The sound pressure level is < db (A) Flow media potable water and heated potable water to a temperature of C and a degree of hardness of d (temporary hardness) heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm²/s
17 Standard circulation pumps for potable water with stainless steel housing BUPA (N) series, T product group Type Connection pipe Threaded connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. BUPA -. N ½ BUPA -. N ½ BUPA -. N ½ BUPA -. N ½ BUPA -. N ½ BUPA -. N ½ BUPA -. N ¾ ¼ BUPA -. N ¾ ¼ BUPA -. N ¾ ¼ BUPA -. N ½ BUPA -. N ½ BUPA -. N ½ BUPA...-. N. BUPA...-. N Q (m / h) Q (m / h) BUPA...-. N..... Q (m / h) Dimensions Type L L L L BUPA (N) // Dimension illustration G L L L L
18 Circulation pumps for potable water with stainless steel housing, pressure head - m BGPA (N) series, T product group Rate of flow: up to. m /h Pressure head: up to m Media temperature: + C to + C Installation length: mm Threaded connection: ¼ and ½ Protection class: IP Insulation class: Nominal pressure: PN Control: -step switch with manual speed selection Product features manual start-up feature space-saving axially integrated terminal box pump housing in stainless steel Use The BGPA (N) series circulation pumps are wet rotor circulators designed for use in potable water systems with a flow rate of > m /h. They feature a corrosionresistant housing in stainless steel and are thus designed for use in potable water circulation systems. Ambient temperature To avoid the build-up of condensation, the ambient temperature must always be lower than the media temperature. Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Materials Component Material Material no. Pump housing Stainless steel. Impeller Polypropylene (PP - GF ) Speed switching The respective speed is set via a rotary switch integrated in the axial terminal box. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Shaft Bearing Media temperature < C C C Minimum inflow pressure. bar. bar. bar Bearing plate Brass. Can Stainless steel. Sound pressure level The sound pressure level is < db (A) Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: + C to + C Flow media potable water and heated potable water to a temperature of C and a degree of hardness of d (temporary hardness) heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm²/s
19 Circulation pumps for potable water with stainless steel housing, pressure head - m BGPA (N) series, T product group Type Connection pipe Threaded connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. BGPA -. N ¾ ¼ BGPA -. N ¾ ¼ BGPA -. N ¾ ¼ BGPA -. N ¾ ¼ BGPA -. N ½ BGPA -. N ½ BGPA -. N ½ BGPA -. N ½ BGPA...-. N Q (m / h) BGPA...-. N Q (m / h) BGPA...-. N Q (m / h) BGPA...-. N Q (m / h) Dimensions Type L L L L BGPA (N). Dimension illustration G L L L L
20 igh efficiency pumps with LED display, electronically controlled EP Optimo Solar series, S product group Insulation shell With installation length mm included in delivery. + Rate of flow: up to. m /h Pressure head: m/ m Control range: - W/- W Media temperature: + C to + C Installation length: and mm Threaded connection:, ½ and Protection class: IP Insulation class: F Nominal pressure: PN Control: pc + pv + fixed rpm EEI:. EP Optimo Solar XX-. GXXX. EP Optimo Solar XX-. GXXX valid for all alm m igh efficiency pumps Flow media heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm²/s operating data must be checked above % glycol Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: + C to + C Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Product features manual start-up feature smooth running very low energy consumption integrated night economy feature air-vent screw LED display convenient operation space-saving axially integrated terminal box automatic adjustment to pressure conditions cataphorectic coated pump housing pre-mounted, screwable angle entry-plug compact design Use The electronically controlled EP Optimo Solar high efficiency wet rotor circulators with LED display and permanent magnet technology are designed for use in solar systems with variable or constant rate of flow. The cataphoretic coated pump housing is stainless. Mode of operation p control When thermostatic valves in systems with a long main supply heating pipe (likely for radiator systems) close, the total flow drops. This results in lower pipe resistance in this main pipe, which means the pump has to create lower head. Using proportional pressure mode PP ( ) is the best setting for such heating systems, as here the pump decreases head at lower flow. If the main supply heating pipe has not to be taken into consideration, because it is short or has its own pump (likely for underfloor heating systems with in mixing units integrated pumps or solar systems), best mode to go with is constant pressure mode CP ( ). In such heating systems, it is important always to have constant pressure for the radiators or ufh-circuits, as the pressure loss in the main pipe is not considered and all other consumers are installed in parallel, which does not influence the maximum pressure loss. Integrated night economy feature When the automatic night economy feature is activated, the circulation pump switches between normal mode and economy mode (characteristic curve MIN). The flow temperature is detected by a temperature sensor, the pump reacts accordingly. For this, it is necessary for the circulation pump to be installed in flow. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < C > C Minimum inflow pressure. bar. bar Sound pressure level The sound pressure level is < db (A) Choice of control characteristic You can set different control modes via the potentiometer on the axial terminal box. Proportional pressure ( ), fixed speed ( ) and constant pressure ( ) can be adjusted continuously variable. The display indicates power consumption in [W] watts. Once the potentiometer is turned, the display first indicates mode of operation (PP, SC, CP), then value of set head in [m] meters. At the factory setting the potentiometer is in mode PP. Main areas of use solar systems Materials Component Material Material no. Pump housing Grey-cast iron. Impeller Polyamide (PA - GF ) Shaft Bearing Bearing plate Stainless steel. Can Stainless steel.
21 igh efficiency pumps with LED display, electronically controlled EP Optimo Solar series, S product group Type Connection pipe Threaded connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. EEI EP Optimo Solar -. G ½ EP Optimo Solar -. G ½ EP Optimo Solar -. G ¼ EP Optimo Solar -. G ¼ EP Optimo Solar -. G ½ EP Optimo Solar -. G ½ EP Optimo Solar -. G ¾ ¼ EP Optimo Solar -. G ¾ ¼ EP Optimo Solar -. G ½ EP Optimo Solar -. G ½ Constant pressure EP Optimo Solar...-.-G Q (m / h) EP Optimo Solar...-.-G Q (m / h) Proportional pressure EP Optimo Solar...-.-G Q (m / h) EP Optimo Solar...-.-G Q (m / h) Fixed rpm EP Optimo Solar...-.-G Q (m / h) EP Optimo Solar...-.-G Q (m / h) Dimensions Dimension illustration G Type L L L L EP Optimo Solar / L L L L
22 igh efficiency pumps with LCD display, electronically controlled EP Optimo L Solar series, S product group Insulation shell included in delivery. + Rate of flow: up to m /h Pressure head: m/ m Control range: - W/- W Media temperature: + C to + C Installation length: mm (thread)/ mm (flange) Threaded connection: ½ and (thread)/dn and DN (flange) Protection class: IP Insulation class: F Nominal pressure: PN EEI:. EP Optimo L XX-. G. EP Optimo L XX-. G Control: Internal: External: pc + pv + fixed rpm digital: PWM (characteristic lines for heating and solar per VDMA device paper ) frequency f nominal: - z voltage U nominal: - V power I: ma analogue: - V with cable break detection power I: ma impedance: kohm Omnibus fault message: Selector switch, potential-free, power max. A/ VAC Power supply for external unit: Voltage DC V, power max. ma Product features LCD display manual start-up feature smooth running very low energy consumption air-vent screw collective fault signal convenient operation axially integrated terminal box automatic adjustment to pressure conditions cataphoretic coated pump housing Use The electronically controlled EP Optimo L Solar high efficiency wet rotor circulators with LCD display and permanent magnet technology are designed for use in heating systems with variable or constant rate of flow. The cataphoretic coated pump housing is stainless. Main areas of use solar systems Controls Function You can make adjustments with the integrated control keys at the front. The LCD display shows the total electrical input power as a numeric value in [W] watts. Different icons at the top of the display show the function, setting and the modes of operation. Materials Component Material Material No. Pump body Grey-cast iron. Impeller Polyamide (PA - GF ) Shaft Bearing Bearing plate Stainless steel. Can Stainless steel. Flow media heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm²/s operating data must be checked above % glycol Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: + C to + C Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < C > C Minimum inflow pressure. bar. bar Sound pressure level The sound pressure level is < db (A)
23 igh efficiency pumps with LCD display, electronically controlled EP Optimo L series, S product group Type Connection pipe Threaded connection Flange Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. EEI EP Optimo L Solar -. G ½ EP Optimo L Solar -. G ½ EP Optimo L Solar -. G ¼ EP Optimo L Solar -. G ¼ EP Optimo L Solar -. G - - DN EP Optimo L Solar -. G - - DN EP Optimo L Solar -. G - - DN EP Optimo L Solar -. G - - DN Proportional pressure Constant pressure Fixed rpm EP Optimo L Solar...-. G EP Optimo L Solar...-. G EP Optimo L Solar...-. G step step step LOW LOW Q (m / h) Q (m / h) Q (m / h) Proportional pressure Constant pressure Fixed rpm EP Optimo L Solar...-. G EP Optimo L Solar...-. G step EP Optimo L Solar...-. G step LOW Q (m / h) LOW Q (m / h) step Q (m / h) Dimensions Type L L L L EP Optimo L (thread) EP Optimo L (flange). Dimension illustration L L L L A
24 EP BB Babelbox BB and EP PWM, S product group Supply voltage: V Power input:. W Signal input leading edge: - V Signal input trailing edge: - V Signal input wave packet: - V, z Signal input power consumption:. ma PWM output: V DC, ma Frequency: z Ambient temperature: C to + C Cable connection input: x M Dimensions: x x mm Weight:. kg Use The Babelbox BB is designed for use in heating systems in which an on-site controller pulses a standard pump via the power line and this pump is to be replaced by a high-efficiency pump. igh-efficiency pumps do not react to a pulsed power line and therefore cannot simply substitute for a standard pump. Interposing the Babelbox BB solves this issue while retaining the control functions of the system. Mode of operation The BB automatically detects if an on-site controller is pulsing the power line via a wave packet or is outputting leading or trailing edge voltage. The BB converts this into a PWM signal which is identified by the alm PWM pump. Just like the standard pump previously, its power is also then controlled. An integrated LED shows the presence of voltage from the on-site controller. Main areas of use All applications in which a standard pump controlled externally by the power line is to be replaced by a high-efficiency pump. Return flow boost Solar installation Differential temperature controlled underfloor heating Storage charging circuit Freshwater station (suitability should be checked with the manufacturer due to the highly sensitive controlled system) Installation Stable cable bushings and elevator terminals enable easy installation. The BB must be connected to V voltage, with the PWM pump and the pulsed power line. Fully automatic detection of the input signal means no further settings need be adjusted. Motor (high efficient ECM technology) Power supply nominal: - V, - z Power consumption: Version m (- W); Version m (- W) Power consumption stand-by PWM:. W PWM connection PWM input: Frequency f nominal: Voltage U nominal: Power PWM to V: Power PWM to V: Insulation voltage optocoupler: - z - V max. ma max. ma VRMS (T ein / T pwm ) x Standards //EG, //EG, //EG EN -, EN --, EN -:+A:, EN -:+A.+A: EN -:, EN --:, EN, EN --, EN --, EN -, EN - The Babelbox BB solution! It was previously not possible to replace standard heating pumps driven by wave packet, leading or trailing edge control with high-efficiency pumps. For the first time, this can now be done with the Babelbox BB. Fully automatic signal detection! Typical high-efficiency pumps require a V constant voltage supply. If, however, a high-efficiency pump is connected to a variable power voltage supply (solar controller, freshwater station controller, charging controller etc.), it reacts neither to a wave packet nor leading edge control as desired. This is where the Babelbox BB from alm comes in. It independently and fully automatically detects which signal is being output by the controller of the standard pump and converts it into a PWM signal which can be understood by the high-efficiency pump, controlling the latter in just the same way as the previously installed standard pump. The voltage supply for the high-efficiency pump itself comes from a separate V connection.
25 EP BB Babelbox BB and EP PWM, S product group Type Connection pipe Threaded connection Installation length (mm) P (W) In (A) Weight (kg) Product no. EP BB -. G " ½" EP BB -. G " ½" EP BB -. G ¼" " EP BB -. G ¼" " EP BB -. G ½" " EP BB -. G ½" " EP BB -. G " ½" EP BB -. G " ½" EP PWM...-.-G Q (m / h) EP PWM...-.-G Q (m / h).,.....,......
26 igh efficiency pumps with LED display, electronically controlled and protected against condensation EP Optimo Geo series, G product group Insulation shell With installation length mm included in delivery. Rate of flow: up to. m / h Pressure head: m/ m Control range: - W/- W Media temperature: - C to + C Installation length: and mm Threaded connection:, ½ and Protection class: IP Insulation class: F Nominal pressure: PN Control: pc + pv + fixed rpm EEI:. EP Optimo Geo XX-. GXXX. EP Optimo Geo XX-. GXXX valid for all alm m igh efficiency pumps + Flow media heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm²/s operating data must be checked above % glycol Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: - C to + C Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Product features manual start-up feature smooth running very low energy consumption integrated night economy feature air-vent screw LED display convenient operation space-saving axially integrated terminal box automatic adjustment to pressure conditions cataphorectic coated pump housing pre-mounted, screwable angle entry-plug compact design Use The electronically controlled EP Optimo Geo high efficiency wet rotor circulators with LED display and permanent magnet technology are designed for use in heating and cold water circulation systems with variable or constant rate of flow. The motor integrity offers a sealed winding protection from ingress of condensation. The cataphoretic coated pump housing is stainless. Mode of operation p control When thermostatic valves in systems with a long main supply heating pipe (likely for radiator systems) close, the total flow drops. This results in lower pipe resistance in this main pipe, which means the pump has to create lower head. Using proportional pressure mode PP ( ) is the best setting for such heating systems, as here the pump decreases head at lower flow. If the main supply heating pipe has not to be taken into consideration, because it is short or has its own pump (likely for underfloor heating systems with in mixing units integrated pumps) or heating pumps, best mode to go with is constant pressure mode CP ( ). In such heating systems, it is important always to have constant pressure for the radiators or ufh-circuits, as the pressure loss in the main pipe is not considered and all other consumers are installed in parallel, which does not influence the maximum pressure loss. Integrated night economy feature When the automatic night economy feature is activated, the circulation pump switches between normal mode and economy mode (characteristic curve MIN). The flow temperature is detected by a temperature sensor, the pump reacts accordingly. For this, it is necessary for the circulation pump to be installed in flow. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < C > C Minimum inflow pressure. bar. bar Sound pressure level The sound pressure level is < db (A) Choice of control characteristic You can set different control modes via the potentiometer on the axial terminal box. Proportional pressure ( ), fixed speed ( ) and constant pressure ( ) can be adjusted continuously variable. The display indicates power consumption in [W] watts. Once the potentiometer is turned, the display first indicates mode of operation (PP, SC, CP), then value of set head in [m] meters. At the factory setting the potentiometer is in mode PP. Main areas of use eating, air-conditioning and industry systems as dual pipe system underfloor heating boiler/primary circuit storage charging circuit solar systems and heating pumps Materials Component Material Material no. Pump housing Grey-cast iron. Impeller Polyamide (PA - GF ) Shaft Bearing Bearing plate Stainless steel. Can Stainless steel.
27 igh efficiency pumps with LED display, electronically controlled and protected against condensation EP Optimo Geo series, G product group Type Connection pipe Threaded connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. EEI EP Optimo Geo -. G ½ EP Optimo Geo -. G ½ EP Optimo Geo -. G ¼ EP Optimo Geo -. G ¼ EP Optimo Geo -. G ½ EP Optimo Geo -. G ½ EP Optimo Geo -. G ¾ ¼ EP Optimo Geo -. G ¾ ¼ EP Optimo Geo -. G ½ EP Optimo Geo -. G ½ Constant pressure EP Optimo Geo...-.-G Q (m / h) EP Optimo Geo...-.-G Q (m / h) Proportional pressure EP Optimo Geo...-.-G Q (m / h) EP Optimo Geo...-.-G Q (m / h) Fixed rpm EP Optimo Geo...-.-G Q (m / h) EP Optimo Geo...-.-G Q (m / h) Dimensions Type L L L L EP Optimo Geo / Dimension illustration G L L L L
28 igh efficiency pumps with LCD display, electronically controlled and protected against condensation EP Optimo L Geo series, G product group Insulation shell included in delivery. + Rate of flow: up to m /h Pressure head: m/ m Control range: - W/- W Media temperature: - C to + C Installation length: mm (thread)/ mm (flange) Threaded connection: ½ and (thread)/dn and DN (flange) Protection class: IP Insulation class: F Nominal pressure: PN EEI:. EP Optimo L XX-. G. EP Optimo L XX-. G Control: Internal: External: pc + pv + fixed rpm digital: PWM (characteristic lines for heating and solar per VDMA device paper ) frequency f nominal: - z voltage U nominal: - V power I: ma analogue: - V with cable break detection power I: ma impedance: kohm Omnibus fault message: Selector switch, potential-free, power max. A/ VAC Power supply for external unit: Voltage DC V, power max. ma Product features LCD display manual start-up feature smooth running very low energy consumption air-vent screw collective fault signal convenient operation axially integrated terminal box automatic adjustment to pressure conditions cataphoretic coated pump housing Use The electronically controlled EP Optimo L Geo high efficiency wet rotor circulators with LCD display and permanent magnet technology are designed for use in heating systems with variable or constant rate of flow. The cataphoretic coated pump housing is stainless. Main areas of use eating, air-conditioning and industry systems as dual pipe system single pipe system underfloor heating boiler/primary circuit storage charging circuit solar systems and heating pumps Materials Component Material Material No. Pump body Grey-cast iron. Impeller Polyamide (PA - GF ) Shaft Bearing Bearing plate Stainless steel. Can Stainless steel. Flow media heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm²/s operating data must be checked above % glycol Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: - C to + C Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < C > C Minimum inflow pressure. bar. bar Controls Function You can make adjustments with the integrated control keys at the front. The LCD display shows the total electrical input power as a numeric value in [W] watts. Different icons at the top of the display show the function, setting and the modes of operation. Sound pressure level The sound pressure level is < db (A)
29 igh efficiency pumps with LCD display, electronically controlled and protected against condensation EP Optimo L Geo series, G product group Type Connection pipe Threaded connection Flange Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. EEI EP Optimo L Geo -. G ½ EP Optimo L Geo -. G ½ EP Optimo L Geo -. G ¼ EP Optimo L Geo -. G ¼ EP Optimo L Geo -. G - - DN EP Optimo L Geo -. G - - DN EP Optimo L Geo -. G - - DN EP Optimo L Geo -. G - - DN Proportional pressure Constant pressure Fixed rpm EP Optimo L Geo...-. G EP Optimo L Geo...-. G EP Optimo L Geo...-. G step step step LOW LOW Q (m / h) Q (m / h) Q (m / h) Proportional pressure Constant pressure Fixed rpm EP Optimo L Geo...-. G EP Optimo L Geo...-. G step EP Optimo L Geo...-. G step step LOW LOW Q (m / h) Q (m / h) Q (m / h) Dimensions Type L L L L EP Optimo L (thread) EP Optimo L (flange). Dimension illustration L L L L A
30 Condensate pump for gas condensing boilers up to kw Lift series, K product group Use The Lift condensate pump is a fully automatic unit for the extraction of condensate, produced in gas/oil condensing boilers, air-conditioning systems, refrigerated counters and dehumidifiers incl. collection tank. It can be used anywhere where a condensate disposal through gravity is not possible or where there is no direct drain. The Lift condensate pump is designed for gas condensing boilers up to kw. The housing is made from ABS plastic and is therefore resistant to acidic condensate (p ). For very acidic condensate (p < ), for the use of low-sulfur heating oil and for installations/systems with over kw, it is compulsory according to ATV- DVWK-A in Germany to install a neutralization system (see condensate pump Lift NT resp. additional neutralization tank NT). Complementary municipal or other national regulations must be observed where necessary. For the use in oil condensing boilers we recommend the additional use of an extension kit with activated carbon (see accessories for condensate pumps). Electrical connection: V, / z Input power: W Alarm contact: max. V, A (resistive load), NO normally open/nc normally closed Protection class: IP Medium: condensate p, temperature C max Rate of flow: max. l/h Pressure head: max. m Noise level: max. db [A] Dimensions: x x mm (L x W x ) Condensate supply: Ø mm Condensate suction head: mm Tank: ABS plastic, max.. l/. Gal Condensation drain: nozzles for hose connection Ø x mm Discharge hose: included in the scope of delivery Weight:. kg Product features fully automatic condensate pump delivered completely ready for connection Main areas of use gas condensing boilers oil condensing boilers air-conditioning systems refrigerators, refrigerated cabinets, refrigerated counters* dehumidifiers, evaporators *) not suitable for splash water Flow media Condensates with a p and a C max temperature. Condensates with a p over have to be neutralized. Condensates with oil residues from oil condensing boilers must be cleaned with activated carbon (extension kit) if necessary. Temperature range Media temperature: + C to + C Ambient temperature: + C to + C Switching points Alarm max. mm Start +/- mm Stop +/- mm extremely quiet and vibration free very compact and space-saving construction fully encapsulated pump unit (IP ) resistant to water jets from any direction pump unit also suitable for use in external tank (tank height min. mm, max. mm) integrated check valve for discharge hose condensation discharge hose ( m, Ø x mm) included in delivery pre-mounted power cable (. m) incl. shockproof plug overflow protection through separate float potential-free alarm connection (NO normally open/nc normally closed) pre-mounted alarm cable (. m) incl. wall mounting Delivery program Lift Q (l/h) Type Max pressure head Max rate of flow For condensing boilers up to Remarks Product no. Lift m l/h kw incl. pressure hose ( m, Ø x mm) -
31 Condensate pump for gas condensing boilers up to kw Lift Basic series, K product group Use The Lift Basic condensate pump is a fully automatic unit for the extraction of condensate, produced in gas/oil condensing boilers, air-conditioning systems, refrigerated counters and dehumidifiers incl. collection tank. It can be used anywhere where a condensate disposal through gravity is not possible or where there is no direct drain. The Lift Basic condensate pump is designed for gas condensing boilers up to kw. The housing is made from ABS plastic and is therefore resistant to acidic condensate (p ). For very acidic condensate (p < ), for the use of low-sulfur heating oil and for installations/systems with over kw, it is compulsory according to ATV- DVWK-A in Germany to install a neutralization system (see condensate pump Lift NT resp. additional neutralization tank NT). Complementary municipal or other national regulations must be observed where necessary. For the use in oil condensing boilers we recommend the additional use of an extension kit with activated carbon (see accessories for condensate pumps). Electrical connection: V, / z Input power: W Alarm contact: max. V, A (resistive load), NO normally open/nc normally closed Protection class: IP Medium: condensate p, temperature C max Rate of flow: max. l/h Pressure head: max. m Noise level: max. db [A] Dimensions: x x m (L x W x ) Condensate supply: Ø mm Condensate suction head: mm Tank: ABS plastic, max.. l/. Gal Condensation drain: nozzles for hose connection Ø x mm Discharge hose: included in the scope of delivery Weight:. kg Main areas of use gas condensing boilers oil condensing boilers air-conditioning systems refrigerators, refrigerated cabinets, refrigerated counters* dehumidifiers, evaporators *) not suitable for splash water Flow media Condensates with a p and a C max temperature. Condensates with a p over have to be neutralized. Condensates with oil residues from oil condensing boilers must be cleaned with activated carbon (extension kit) if necessary. Temperature range Media temperature: + C to + C Ambient temperature: + C to + C Product features fully automatic condensate pump delivered completely ready for connection extremely quiet space-saving construction housing made from ABS plastics is resistant to condensate integrated check valve for discharge hose condensation discharge hose ( m, Ø x mm) included in delivery pre-mounted power cable (. m) incl. shockproof plug overflow protection through separate float potential-free alarm connection (NO normally open/nc normally closed) pre-mounted alarm cable (. m) incl. wall mounting Delivery program Lift Basic Q (l/h) Type Max pressure head Max rate of flow For condensing boilers up to Remarks Product no. Lift Basic m l/h kw incl. pressure hose ( m, Ø x mm) -
32 Condensate pump for oil condensing boilers with neutralization tank Lift NT series, K product group Electrical connection: V, / z Input power: W Alarm contact: max. V, A (resistive load), NO normally open/nc normally closed Protection class: IP Medium: condensate p, temperature C max Rate of flow: max. l/h Pressure head: max. m Noise level: max. db [A] Dimensions: x x m (L x W x ) Condensate supply: Ø mm Condensate suction head: mm Neutralization tank: ABS plastic,. l/. Gal, incl. neutralization granulate ( kg) Condensation drain: nozzles for hose connection Ø x mm Weight:. kg Schematic sketch Lift NT ose nipple suitable for PVC hose, nominal width mm ose length cm Condensate intake Filter Granular Product features fully automatic condensate pump delivered completely ready for connection, incl. neutralization tank noise-reducing electronic controls with follow-up time to reduce switching frequency space-saving construction integrated collection/neutralization tank, incl. first fill with neutralization granulate ( kg) sufficient for about months for systems up to kw upstream suction filter as well as check valve for discharge hose connection for discharge hose (Ø x. mm) Flow direction Main areas of use gas condensing boilers oil condensing boilers Sieve insert with filter Float switch Alarm float switch Flow media Condensates produced in gas and oil condensing boilers with a C max temperature. Condensates with oil residues from oil condensing boilers must be cleaned with activated carbon (extension kit) if necessary. Temperature range Media temperature: + C to + C Ambient temperature: + C to + C pre-mounted power cable (. m) incl. shockproof plug overflow protection through separate float potential-free alarm connection (NO normally open/nc normally closed) Use The Lift NT condensate pump is a fully automatic unit for the extraction of condensate, produced in gas/oil condensing boilers, air-conditioning systems, refrigerated counters and dehumidifiers incl. collection/neutralization tank. It can be used anywhere where a condensate disposal through gravity is not possible or where there is no direct drain. The Lift NT condensate pump is designed for gas and oil condensing boilers up to kw. It is extensible for systems up to kw with additional accessories NB and NT. The housing is made from ABS plastic and is therefore resistant to acidic condensate (p ). For the use in oil condensing boilers we recommend the additional use of an extension kit with activated carbon (see accessories for condensate pumps). Lift NT,,,,,,, Q (l/h)
33 Condensate pump for oil condensing boilers with neutralization tank Lift NT series, K product group Delivery program Type Max pressure head Max rate of flow For condensing boilers up to Remarks Product no. Lift NT m l/h kw incl. neutralization tank incl. first fill with neutralization granulate - Connection alarm cable Electronic circuitry Lift NT N L PE L N PE NO C NC Changeover contact Relay A/ V ohmic load Terminal NO-C: normally open contact NC-C: normally closed contact L N PE Consumer Connection example for potential-free contact Cable length m Lift NT
34 Accessories Z product group Screw connections Type Product no. Description Grey cast iron connection G -. set c.i. connection Rp ½ x G Grey cast iron connection G ¼ -. set c.i. connection Grey cast iron connection G ½ -. set c.i. connection Rp x G ½ Grey cast iron connection G -. set c.i. connection Rp ¼ x G Brass connection G -. set brass connection Rp ½ x G Brass connection G ¼ -. set brass connection Rp ¾ x G ¼ Brass connection G ½ -. set brass connection Rp x G ½ Plug Type Product no. Description Plug complete -- Plug for series EP complete incl. Socket on motor side Socket only - Socket on motor side for plug for series EP Insulation shell Type Product no. Description Insulation shell - Insulation shell (EPP) for series EP installation length mm Further accessories on request. Sample
35 Accessories/Spare parts Z product group Maintenance kit for Lift NT Type Product no. Description Maintenance kit for Lift NT - Maintenance kit for Lift NT for the yearly maintenance consisting of neutralization granulate ( kg), replacement filter sieve with fleece, replacement filter element for suction filters. Extension kit oil condensing boilers Type Product no. Description Extension kit oil condensing boilers - Extension kit for Lift NT for oil condensing boilers consisting of activated carbon filter and sieve. NT Type Product no. Description NT - Additional collection/neutralization tank with granulate ( x kg) for neutralization capacity kw, filter sieves (x) and connection/ nozzle for the connection to the Lift NT. Condensate supply opening Ø mm/condensate supply height mm. NG Type Product no. Description NG - Refill pack neutralization granulate ( kg) Alarm plus Type Product no. Description Alarm plus - Audio and visual fault indicator for the alarm output of the condensate pump ( V, / z) for the connection to the condensate pump with alarm relay output, x x mm (L x W x ), input power. W, IP, ambient temperature + C to + C. Further accessories and spare parts on request.
36 Your representative: Product no. --EN-EU Version. (/) alm Pumpen + Motoren Gmb Silcherstrasse - Baltmannsweiler, Germany Postfach Baltmannsweiler, Germany Tel.: + - Fax: + info@halm.info +
Circulation pumps. Wet rotor circulators and accessories. Heating Drinking water Solar Geothermy Condensate
Circulation pumps Wet rotor circulators and accessories eating Drinking water Solar Geothermy Condensate CATALOGUE alm produces highly-efficient heating circulation pumps alm has been successfully developing
More informationCirculation pumps BAFA. Wet rotor circulators. gefördert. Heating Drinking water Solar Geothermy Condensate
Circulation pumps Wet rotor circulators eating Drinking water Solar Geothermy Condensate BAFA gefördert CATALOGUE ALM produces highly-efficient heating circulation pumps ALM has been successfully developing
More informationPumps BAFA. Heating Drinking water Solar Geothermy Condensate. gefördert
Pumps eating Drinking water Solar Geothermy Condensate BAFA gefördert CATALOGUE The Company For more than years, ALM has developed and produced motors and pumps. In the beginning exclusively for well-known
More informationCirculation pumps. Wet rotor circulators and accessories Heating Drinking water Solar Geothermy Condensate
Circulation pumps Wet rotor circulators and accessories eating Drinking water Solar Geothermy Condensate + CATALOGUE ALM produces highly-efficient heating circulation pumps ALM has been successfully developing
More informationPumps. Heating Drinking water Solar Geothermy Condensate
Pumps eating Drinking water Solar Geothermy Condensate + CATALOGUE The Company For more than years, ALM has developed and produced motors and pumps. In the beginning exclusively for well-known OEM customers,
More informationGRUNDFOS DATA BOOKLET UPS2. Circulator pumps. 50/60 Hz
GRUNDFOS DATA BOOKLET UPS2 Circulator pumps 50/60 Hz UPS2 Table of contents 1. Product introduction 3 Type key.................................................................................... 3 Performance
More informationUP/UPS-B/UPN Hot Water Service Circulators
UP/UPS-B/UPN Hot Water Service Circulators Visions & Values It is the Vision of the Company to achieve our Corporate Mission by providing quality and innovative products and services that give our customers
More informationAPPLICATIONS. For the accelerated circulation of hot water in heating circuits with duty point optimisation
OPERATING RANGE Flow rate of up to m /h Manometric head of up to m Max. operating pressure bar Min. intake pressure, bar at 9 C Water temperature range + at + C * EEI-Part, * for a ambient temperature
More informationPRIUX HOME D. High-efficiency double circulating pumps Heating Air conditioning 50 Hz OPERATING RANGE APPLICATIONS BENEFITS
OPERATING RANGE Flow rate of up to 7 m /h* Manometric head of up to 8 mwc Max. operating pressure bar Min. suction pressure, bar at 9C Temperature range -C at 9C Max. ambient temperature +C EEI-Part Priux
More informationLowara ecocirc and ecocirc PREMIUM
Lowara and PREMIUM THE REVOLUTIONARY HIGHLY EFFICIENT CIRCULATORS FOR DOMESTIC HEATING WITH THE SIMPLE AND SHAFTLESS SPHERICAL MOTOR DESIGN AND PATENTED ANTI-BLOCK TECHNOLOGY How can efficiency work The
More informationLowara ecocirc and ecocirc PREMIUM
Lowara and PREMIUM THE REVOLUTIONARY HIGH EFFICIENCY CIRCULATORS FOR DOMESTIC HEATING WITH THE SIMPLE AND SHAFTLESS SPHERICAL MOTOR DESIGN AND PATENTED ANTI-BLOCK TECHNOLOGY How can efficiency work even
More informationHIGH EFFICIENCY CIRCULATORS. Represented by Taconova Group AG CATALOGUE 2018 EN. easyuse. greatperformance
HIGH EFFICIENCY CIRCULATORS Represented by Taconova Group AG CATALOGUE 218 EN easyuse greatperformance CONTENTS WELCOME...3 HEATING SYSTEMS ES2 6...4 ES2 7...6 ES2 C A 6...8 ES2 ADAPT 6...1 ES2 ADAPT 7...12
More informationLowara ecocirc and ecocirc PREMIUM THE NEW HIGHLY EFFICIENT CIRCULATORS WITH THE PATENTED ANTI-BLOCK-TECHNOLOGY
NE W Lowara ecocirc and ecocirc PREMIUM THE NEW HIGHLY EFFICIENT CIRCULATORS WITH THE PATENTED ANTI-BLOCK-TECHNOLOGY Ecocirc_Premium_uk.indd 1 28/10/13 12.26 How can efficiency even w The simple spherical
More informationGRUNDFOS DATA BOOKLET. Grundfos COMFORT. Circulator pumps. 50/60 Hz
GRUNDFOS DATA BOOKLET Circulator pumps 50/60 Hz 2 Product range 2. Product range UP(S) COMFORT, 50/60 Hz Pump type 24-hour timer Supplied with Dimensions Accessories Data sheet Thermostat Isolating valve
More informationCirculation Pump Optima
ECO DESIGN Circulation Pump Optima The First&Only According to Directives AT THE HEART OF THE SYSTEM ErP READY LOW ENERGY CONSUMPTION SAVE the NATURE Over years of Alarko experience in Circulation Pumps...
More informationAffordable efficiency!
Lowara Ecocirc THE REVOLUTIONARY HIGHLY EFFICIENT CIRCULATORS FOR DOMESTIC HEATING WITH THE SIMPLE AND SHAFTLESS SPHERICAL MOTOR DESIGN AND PATENTED ANTI-BLOCK-TECHNOLOGY. Affordable efficiency! Approximately
More informationHigh-efficiency circulating pumps Heating Air conditioning 50 Hz
OPERATING RANGE Flow rate of up to m /h Manometric head of up to 8 mwc Max. operating pressure bar Min. suction pressure, bar at 9 C Temperature range - C at 9 C Max. ambient temperature + C EEI-Part,
More informationAHW AHW(S) Hot water circulator pump INSTALLATION AND OPERATING INSTRUCTIONS HIGH-EFFICIENCY BLDC-MOTOR CIRCULATORS
AHW AHW(S) Hot water circulator pump INSTALLATION AND OPERATING INSTRUCTIONS HIGH-EFFICIENCY BLDC-MOTOR CIRCULATORS EC Declaration of Conformity Declare that machinery described: AHW,AHW(S) Hot water circulator
More informationGrundfos is pleased to announce the sales release of many exciting new products.
GRUNDFOS BULLETIN Title: Sales Release Announcement Bulletin Number: DB-219-9-1 To: Grundfos Partners January 9, 219 Dear Partners, Grundfos is pleased to announce the sales release of many exciting new
More informationHIGH EFFICIENCY CIRCULATORS
HIGH EFFICIENCY CIRCULATORS Heating, Cooling, Solar Thermal and Domestic Hot Water SAVINGS Up to 80% less than traditional pumps TECHNOLOGY Best available technology - PM Motor ENVIRONMENT Environment
More informationHeat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min
Heat on Air heaters from 400 Watt to 17 400 Watt Blowers from 1,45 m 3 /min to 16,5 m 3 /min BAK Thermoplastic Need-to-know Calculation of air heaters 1. Heat requirement calculation Formula: Q = m * c
More informationCOMPASS HIGH-EFFICIENCY WET-ROTOR CIRCULATORS
COMPASS HIGH-EFFICIENCY WET-ROTOR CIRCULATORS INSTALLATION AND OPERATING INSTRUCTIONS File No: 10.895 Date: march 8, 014 Supersedes: 10.895 Date: december 10, 013 1.0 Symbols used in this document 1.0
More information1 Declaration of conformity
ENERGY SAVING 1 Declaration of conformity We Taco Italia S.r.l. declare under our sole responsibility that the family of products ENERGY SAVING to which this declaration relates are in conformity with
More informationGRUNDFOS DATA BOOKLET MAGNA3. Circulator pumps 60 Hz
GRUNDFOS DATA BOOKLET Circulator pumps 60 z Table of contents 1. Product introduction 3 Features and benefits 3 Applications 3 2. Performance range 4 4 D single-head operation 5 D twin-head operation 6
More informationMAGNA3 MAGNA3. The full Grundfos product range covers all building application areas:
MAGNA3 We offer a complete range of MAGNA3 pumps with unrivalled efficiency, intelligent technology to match your every need and the well-known Grundfos reliability based on years of experience. MAGNA3
More informationEW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS
Design Hydronic meters of the EW447-452 Series consist of: Electronic energy integrator with fixed cable connection to the volume measuring component, supply and return temperature probe Mechanical volume
More informationCR20-07 A-F-A-E-HQQE 3x400/ HZ
GRUNDFOS DATA BOOKLET CR2-7 A-F-A-E-HQQE 3x4/69 5 HZ Grundfos pump 965513 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/crfam/965513/cr-2-7-a-f-a-e-hqqe.html
More informationVMA-VMB NOVA AIR HEATERS. NoVa air heaters
VMA-VMB NOVA AIR HEATERS NoVa air heaters PRODUCT FACTS PRODUCT The Novenco NoVa air heaters are water-based units with hot-water heating coils and axial flow fans fitted in cabinets. VMA for 10-20 C cooling
More informationTP /4-A-F-A-BQQE 400D 50HZ
GRUNDFOS DATA BOOKLET TP 15-7/-A-F-A-BQQE D 5HZ Grundfos pump 989838 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tp/989838/tp-15-7--a-f-a-bqqe.html
More informationMORE DEMAND THAN A PUMP GRUNDFOS MAGNA3
GRUNDFOS MAGNA3 DEMAND MORE TAN A PUMP Full range of intelligent, high-efficiency circulators for heating, cooling, ground source heat pump systems and domestic hot water applications MORE TAN A PUMP IF
More informationCR A-F-A-E-HQQE 3x400/ HZ
GRUNDFOS DATA BOOKLET CR32--2 A-F-A-E-HQQE 3x/69 5 HZ Grundfos pump 9612212 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/crfam/9612212/cr-32--2-a-f-a-e-hqqe.html
More informationMAGNA3 More than A pump
MAGNA3 More than A pump Full range of intelligent, high-efficiency circulators for heating, cooling, ground source heat pump systems and domestic hot water applications Features More than a pump If you
More information50/60 Hz. ecocirc BASIC Series WET ROTOR CIRCULATORS FOR HEATING, COOLING AND SANITARY SYSTEMS. ErP 2009/125/EC
/ Hz ecocirc BASIC Series WET ROTOR CIRCULATORS FOR HEATING, COOLING AND SANITARY SYSTEMS ErP 9//EC Cod. 9 Rev. C Ed./ ecocirc BASIC SERIES INSTALLATION POSITIONS Lowara, ecocirc, Xylect are trademarks
More informationCALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function
Thermostatic regulating unit for heating systems 66 series ACCREDITED ISO 9 FM 6 8/7 GB replaces dp 8/ GB Function The thermostatic regulating unit performs the function of keeping the flow temperature
More informationFHM-Cx Mixing Shunts for Floor Heating
FHM-Cx Mixing Shunts for Floor Heating Application Mixing shunt FHM-C5/C6 (UPS pump) The Danfoss compact mixing shunts are used for regulation of flow and supply temperature in hydronic floor heating systems.
More informationACT-4 AC Electronically Commutated Spherical Motor Centrifugal Pump Kit
SPECIFICATIONS SS-20 ACT-4 AC Electronically Commutated Spherical Motor Centrifugal Pump Kit Application: Specifically designed for hot water recirculation in a residential or light commercial building.
More informationVERSO Air Handling Units
Energy efficient solutions for profitable indoor climate VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P air handling units equipped with recuperation system
More informationZeparo Cyclone. Automatic air vents and separators Dirt and magnetite separator with Cyclonic technology
Zeparo Cyclone Automatic air vents and separators Dirt and magnetite separator with Cyclonic technology IMI PNEUMATEX / Air Vents, Dirt Separators and Degassing / Zeparo Cyclone Zeparo Cyclone Comprehensive
More informationTechnical Product Guide
FMU - Floor Mixing Unit Boxed set pre-assembled for immediate installation: The FMU Floor Mixing Unit integrates both temperature and flow management, making the single piece unit very easy to install,
More informationData Sheet. Compact Mixing Shunt for Floor Heating, FHM-Cx. Application:
Data Sheet Compact Mixing Shunt for Floor Heating, FHM-Cx Application: FHM-C1 Mixing shunt FHM-C/ FHM-C Mixing shunt FHM-C Mixing shunt FHM-C The Danfoss floor heating compact mixing shunts are used for
More informationDistrict heating controller for two heating circuits and d.h.w. according to Siemens specifications:
4 319 2984 0 G2384en en Installation Instructions District heating controller for two heating circuits and d.h.w. RVD240 Installation Place of installation In a dry room, e.g. in the heat exchanger room
More informationInstallation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump
Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Reduced Installation time Precision regulation Minimal tooling required 100% tested prior to packaging High quality
More information4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction
4VH and 4VHX 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction DURABLE MOTOR WILL DELIVER MANY YEARS OF RELIABLE SERVICE Oil-filled motor for maximum heat dissipation
More informationFIL-SPL Flow-through heater for central heating USER MANUAL
FIL-SPL Flow-through heater for central heating with 0-10 V EP 15-30 control unit USER MANUAL Kaukora LTD. D106159 r3.0 Contents 1. Important information... 5 Safety information... 5 General... 5 Marking...
More informationULTRAFLOW 54 DN
Data sheet ULTRAFLOW 54 DN150-300 For flow from 150 m³/h up to 1000 m³/h Ultrasonic flow sensor Compact design Static meter, no moving parts Large dynamic range No wear High accuracy Longevity MID-2004/22/EC
More informationTECHNICAL DESCRIPTION
TECHNICAL DESCRIPTION pumps are Hi-Tech single stage, horizontal centrifugal pumps with magnetic driven coupling. In compact and silent close-coupled execution, they can be mounted on to B5 frame motors.
More informationTaco 00 Series Cartridge Circulators
Water Circulation Pumps & Circulators Taco 00 Series Cartridge Circulators For over 70 years, Taco has led the industry with the highest quality circulators you can buy. Designed for a wide range of residential
More informationecocirc vario Efficiency is affordable! The revolutionary heating circulator Efficiency at low price:
Efficiency is affordable! The revolutionary heating circulator ecocirc vario Ecocirc E4vario Ecocirc E6vario Efficiency at low price: The revolutionary ecocirc vario. With efficient electronically commutated
More information2604 Controller Melt Pressure Controller
2604 Controller Melt Pressure Controller A. SUPPLEMENT 2604 MELT PRESSURE CONTROLLER. 2 A.. INTRODUCTION...2 A.2. WHAT IS THE MELT PRESSURE CONTROLLER?...2 a.3. INSTALLATION...3 a.4. WIRING CONNECTIONS...3
More informationComfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W
Comfort Ceiling Fan Coil System INDULVENT ec NEW Draught-free ambient air distribution with cooling capacity up to 2600 W Low sound power levels Only electrical, cooling water and condensate connections
More information1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W
594 59P0 Flow switch for liquids in piping DN 0 00. QE90 Contact load / switching capacity: Nominal pressure PN5 Manual setting of contact type (NO / NC) Housing IP 65 / safety class II Maintenance free
More informationSpandau Pumps. Sealless Immersion Pumps for Industrial Applications. Overwiev of Products
Spandau Pumps Overwiev of Products 1-6000-US Sealless Immersion Pumps for Industrial Applications Centrifugal and screw pumps for low-, medium- and high-pressure applications Quality Management DIN EN
More information1592P01. for liquids in piping DN
1 594 1592P01 Flow switch for liquids in piping DN 20 200. QVE1901 Contact load / switching capacity: max. AC 230 V, 1 A, 26 VA max. DC 48 V, 1 A, 20 W Nominal pressure PN25 Manual setting of contact type
More informationFT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series
FT702LT Turbine control wind sensor......gives durability a new meaning FT702LT series Proven High Availability The FT702LT ultrasonic anemometer is the result of FT Technologies 10 years of experience
More informationCalio-Therm S NC/NCV Type Series Booklet
High-efficiency Drinking Water Pump Calio-Therm S NC/NCV Type Series Booklet Legal information/copyright Type Series Booklet Calio-Therm S NC/NCV All rights reserved. The contents provided herein must
More information2CP DATA SHEET. Horizontal Two Stage Centrifugal Pumps 2CP 32/210B 2CP 32/200B 2CP 32/200C
MADE IN ITALY DATA SHEET Horizontal Two Stage Centrifugal Pumps 2CP 20 2CP 32/20A 00 2CP 32/20B 80 2CP 32/200B HEAD [m] 60 2CP 32/200C 40 20 0 2 4 6 8 0 2 4 6 3 FLOW [m /hr] Linz Electric is a brand of
More informationThe solutions are here The choice is yours...
Hydronic Balancing and Control The solutions are here The choice is yours... 1255 products to support your business The extended Hydronic Balancing and Control product range offers a solution for every
More informationHORIZONTAL MULTISTAGE CENTRIFUGAL PUMP
HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP WWPPCHLFT260 Instructions WWPPCHLFT260_Horizontal Multistage Centrifugal Pump_IB.indd 1 READ THIS MANUAL CAREFULL BEFORE INSTALL, START THE PUMP 1. Suction 2. Plug
More informationIMMERSIBLE PUMPS FOR INDUSTRY
GRUNDFOS INDUSTRIAL SOLUTIONS Grundfos MTR, MTH, MTA, MTS pumps IMMERSIBLE PUMPS FOR INDUSTRY COMPACT TANK TOP SOLUTIONS FOR DEMANDING APPLICATIONS RENOWNED FOR THEIR RELIABILITY AND PRECISION MTA MTH
More informationCERAMIC PUMPS FGP. Horizontal Liquid Ring Pumps Solid and gas-tight silicate ceramic for gases and vapours.
CERAMIC PUMPS FGP Horizontal Liquid Ring Pumps Solid and gas-tight silicate ceramic for gases and vapours. FGP THE SOPHISTICATED PUMP CONCEPT If you want to solve demanding pumping tasks in the industry
More informationVERSO Air Handling Units
VERSO Air Handling Units Energy efficient solutions for profitable indoor climate VERSO Air Handling Units VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P
More informationTECHNICAL. Series 18. Pump Packages
TECHNICAL S Y S T E M S Series 18 Pump Packages Series 18 Pump Packages Standard Features Close-coupled, end-suction, centrifugal pumps Mounted and wired pump starters Hand-Off-Auto switch for each pump
More informationHeating, air-conditioning, cooling
Series description Design landless circulation pup with threaded connection, blockingcurrent proof EC otor and integrated electronic power control. Application All hot water heating systes, air-conditioning
More informationCALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB
4 RESET ON DHW CH FAULT SATK wall-mounted heat interface unit Fitted for connection to DHW storage SATK4 series ACCREDITED CALEFFI 6/4 GB ISO 9 FM 64 ISO 9 No. The latest generation of heat interface units
More informationSondex - A World of Heat Exchangers For All Applications
Sondex - A World of Heat Exchangers For All Applications SONDEX HEAD OFFICE Sondex - A Leading Manufacturer of Plate Heat Exchangers Sondex A/S, a Danish company, was founded in 1984 by Mr. Aa. Søndergaard
More informationCR64-1 A-F-A-E-HQQE 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CR64-1 A-F-A-E-HQQE 3x4D 5 HZ Grundfos Pump 96123527 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96123527/cr-64-1-a-f-a-e-hqqe.html
More informationCR10-16 A-FJ-A-E-HQQE 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CR1-16 A-FJ-A-E-HQQE 3x4D 5 HZ Grundfos Pump 9651222 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9651222/cr-1-16-a-fj-a-e-hqqe.html
More informationFHM-Cx Mixing Shunts for Floor Heating
Data Sheet FHM-Cx Mixing Shunts for Floor Heating Application A self-acting proportional regulator is used to regulate the supply temperature. The regulator ensures that the desired supply temperature
More informationAutomatic balancing valves ASV-PV (new generation) DN 32-50
Automatic balancing valves ASV-PV (new generation) DN 32-50 ASV-PV DN 32-50 Description ASV whiteboard animation SMT/SI ASV valves are automatic balancing valves. Together with Danfoss presetting radiator
More informationCR A-F-A-V-HQQV 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CR9-1-1 A-F-A-V-HQQV 3x4D 5 HZ Grundfos Pump 9612486 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9612486/cr-9-1-1-a-f-a-v-hqqv.html
More informationCRN A-F-G-E-HQQE 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CRN45-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96123118 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn45/96123118/crn-45-2-2-a-f-g-e-hqqe.html
More informationGRUNDFOS PLUMBING & HVAC PRODUCTS
GRUNDFOS PLUMBING & HVAC PRODUCTS SERIES UP CIRCULATORS GRUNDFOS CIRCULATORS FOR HEATING AND HOT WATER RECIRCULATION Quiet, maintenance-free performance Stainless steel construction, corrosion resistant
More informationOEM Sensors for HVAC manufacturers Heat recovery Chiller
OEM Sensors for HVAC manufacturers Heat recovery Chiller 2 Heat recovery / Chiller Typical magnetic-inductive flow sensor application Product features For determining the energy balance Measurement signal
More informationCERAMIC PUMPS FGP. Horizontal Liquid Ring Pumps Solid and gas-tight silicate ceramic for gases and vapours.
CERAMIC PUMPS FGP Horizontal Liquid Ring Pumps Solid and gas-tight silicate ceramic for gases and vapours. FGP THE SOPHISTICATED PUMP CONCEPT If you want to solve demanding pumping tasks in the industry
More informationPelletizing System Options for Extrusion
Pelletizing System Options for Extrusion by Dana Darley Extrusion Auxiliary Serv ices Dacula, GA (678) 714-5218 www.extrusionauxiliary.com Types of Pelletizing Systems Strand Water Bath Strand Water Slide
More informationRVP360 and RVP361 Heating controllers for 2 heating circuits and d.h.w. Basic Documentation
RVP360 and RVP361 Heating controllers for 2 heating circuits and d.h.w. Basic Documentation Edition 1.0 Controller series A CE1P2546en 15.03.2011 Building Technologies Siemens Switzerland Ltd Industry
More informationCombi Modular System. Standardised centrifugal pumps EN 733 ISO 2858 ISO 5199 API 610
Combi Modular System Standardised centrifugal pumps EN 733 ISO 2858 ISO 5199 API 610 SPX FLOW Johnson Pump brand water, chemical and petrochemical standardised pumps represent a range of centrifugal pumps
More informationPumps Mixers Aeration Controls Services SCANPUMP SPLIT CASING PUMP Z22.
Pumps Mixers Aeration Controls Services SCANPUMP SPLIT CASING PUMP Z22. SERIES Z22 - WHEN GOOD IS NOT ENOUGH. Since we delivered our first process pumps back in the 1870 s, our goal has been to optimize
More informationTransformer oil coolers BETA & CETA
2012.1 Transformer oil coolers BETA & CETA Transformer oil coolers BETA & CETA Luvata is pleased to present to the market its renewed transformer oil coolers. The BETA and CETA series of transformer oil
More informationCombiBloc Close-coupled centrifugal pumps
CombiBloc Close-coupled centrifugal pumps CombiBloc CombiBloc is the premier solution for pumping clean thin liquids in a very cost-effective way. The pump is part of Johnson Pump s Combi-system, a modular
More informationCR A-F-A-E-HQQE 3x400/ HZ
GRUNDFOS DATA BOOKLET CR45-12-2 A-F-A-E-HQQE 3x4/69 5 HZ Grundfos Pump 96122818 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96122818/cr-45-12-2-a-f-a-e-hqqe.html
More informationWallace & Tiernan Liquid Feed System LVN-2000 Liquid V-Notch
Wallace & Tiernan Liquid Feed System LVN-2000 Liquid V-Notch Overview continues to be the leader in the chemical feed and disinfection of potable water, wastewater and industrial process applications.
More informationMODERN TECHNOLOGIES AND LONG - TERM EXPERIENCE
MODERN TECHNOLOGIES AND LONG - TERM EXPERIENCE SVA ATEX AVAILABLE SELFPRIMING SIDE CHANNEL HORIZONTAL PUMPS SIGMA PUMPY HRANICE, s.r.o. Tovární č.p. 605, 753 01 Hranice I - Město, Czech Republic phone:
More informationTEMPORARY SPECIFICATION FOR REFERENCE
TEMPORARY SPECIFICATION FOR REFERENCE Customer : Description : EST FAN (Energy Saving Technology Fan) Customer Part No. REV. : Delta Model No. AFL12AUHE-00 REV. : 02 Sample Issue No. : Sample Issue Date
More informationTECHNICAL DESCRIPTION
TECHNICAL DESCRIPTION The renewed ETN-Lined pumps are singlestage, magnetic driven, centrifugal pumps in closecoupled execution. ETN-Lined pumps are available both inpp+gf and ETFE. The pump casing is
More informationProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data.
ProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data. The RVA63 controller can be utilized to control the following system configurations via LPB communication. Equipment Required
More informationValves, controls + systems. Local and district heating technology. Innovation + Quality. Product range. for improved.
Innovation + Quality Valves, controls + systems Local and district heating technology for improved energy efficiency Product range Local and district heating technology The term Local and district heating
More informationDo you want a versatile solution
Do you want a versatile solution to make significant savings? ESTIA TOSHIBA AIR CONDITIONING RESIDENTIAL HEATING AIR-TO-WATER HEAT PUMP ESTIA hatever you need ESTIA TO MAKE SIGNIFICANT SAVINGS Toshiba
More informationPreconfigured heat interface unit with compact installation depth for preparation of domestic hot water and apartment heating.
T T TACOTHERM DUAL PIKO HEAT INTERFACE UNIT ADVANTAGES Compact installation depth Large number of variants Preconfigured for simple installation On-demand, hygienic preparation of domestic hot water Demand-driven
More informationPRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.
PRODUCT DATA COMPACT P - SERIES BY NILAN Domestic Passive heat recovery Active heat recovery Ventilation < 300 m 3 /h Comfort heating Comfort cooling Sanitary hot water production Heating THE VENTILATION
More informationSmart temperature control solutions
Smart temperature control solutions State-of-the-art heating and cooling solutions, expertise & know-how combined with top quality and superior customer service. 1 1 8 7 5 9 6 10 4 3 2 www.vexve.com Contents
More informationHERZ Differential Pressure Control Valve 4002
HERZ Differential Pressure Control Valve 4002 Data sheet 4002, Issue 0118 Dimensions in mm B1 B2 1 4002 41 1 4002 61 1 4002 71 1 4002 42 1 4002 62 1 4002 72 1 4002 43 1 4002 63 1 4002 73 1 4002 44 1 4002
More informationCALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB
Set point thermostatic regulating unit 8 series FM 65 00 CALEFFI 090/8 GB replaces dp 090/5 GB Function The thermostatic regulating unit is made to be used in radiant panel systems, in combination with
More informationTF Series With SECOPAC LS
SECOTEC Refrigeration Dryers TF Series With SECOPAC LS Flow rate 17.0 to 34.0 m³/min SECOTEC TF The next generation: Even more efficient compressed air drying SECOTEC that's the name of KAESER's renowned
More informationHeating and D.h.w. Controller RVL482 Basic Documentation
Heating and D.h.w. Controller RVL482 Basic Documentation Edition: 1.0 Controller series: A CE1P2542en 20.05.2008 Building Technologies Siemens Switzerland Ltd Building Technologies Group International
More informationFCHM Hydromatic Pump Control Module
FCHM Hydromatic Pump Control Module Use To maintain and control water pressure, within a pumped system, for the supply to industrial processes and heating systems. Ensures constant flow and pressure to
More informationFlame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660
Selectivity Adjustable by Means of - High Pass Frequency Filter - Gain - Threshold Different Adjustments for Different Conditions (e.g. According Fuel or Combustion Technology) Possible, to be Activated
More informationC19 UNIVEX. High Vacuum Experimentation Systems UNIVEX 300, UNIVEX 450 UNIVEX 350, UNIVEX 450 B Special plants
C19 UNIVEX UNIVEX 300, UNIVEX 450 UNIVEX 350, UNIVEX 450 B Special plants Contents General Applications and Accessories / Process Components.............................. C19.02 General................................................................
More informationFlow Switches. Series VHS, VKS, VH
Flow Switches Series VHS, VKS, VH Reliable - Safe - Proven! Our tried-and-tested fl ow monitoring switches for liquids are used for two basic purposes: To ensure a minimum fl ow rate, e.g. of cooling water
More informationMORE DEMAND. than a pump. grundfos MAGNA3
grundfos MAGNA3 DEMAND MORE than a pump Full range of intelligent, high-efficiency circulators for heating, cooling, ground source heat pump systems and domestic hot water applications More than a pump
More information