Calio-Therm S NC/NCV Type Series Booklet

Size: px
Start display at page:

Download "Calio-Therm S NC/NCV Type Series Booklet"

Transcription

1 High-efficiency Drinking Water Pump Calio-Therm S NC/NCV Type Series Booklet

2 Legal information/copyright Type Series Booklet Calio-Therm S NC/NCV All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed for any other purpose, nor otherwise transmitted, published or made available to a third party without the manufacturer's express written consent. Subject to technical modification without prior notice. KSB Aktiengesellschaft, Frankenthal 23/02/2017

3 Contents Contents Building Services: Heating... 4 Drinking Water Circulator Pumps... 4 Calio-Therm S NC... 4 Main applications... 4 Fluids handled... 4 Operating data... 4 Designation... 4 Design details... 4 Materials... 4 Product benefits... 4 Certifications... 5 FluidFuture energy efficiency concept developed by KSB... 5 Selection information... 5 Overview of product features / selection tables... 5 Technical data... 6 Characteristic curves... 6 Dimensions... 7 Installation information... 7 Scope of supply... 7 Accessories

4 Building Services: Heating Drinking Water Circulator Pumps Building Services: Heating Code NCV Drinking Water Circulator Pumps S Calio-Therm S NC Description NCV Fixed speed with integrated non-return valve and shut-off valve (ball valve) Connection variants S With plug-type connection K With power cable 1) Design details Maintenance-free glandless pump Screw-ended Three speed levels Operating modes Operation at fixed speed Manual functions Setting the speed level Drive Short-circuit-proof electric motor 230 V - 50/60 Hz IP42 enclosure Thermal class F Temperature class TF 60 Main applications Drinking water circulation systems Interference emission EN : A1: A2:2011, EN : A1: A2:2009, EN :2008 Interference immunity EN : A1: A2:2008 Fluids handled Drinking water and heated drinking water of up to 65 C Fluids with a maximum kinematic viscosity of 10 mm²/s Bearings Product-lubricated Operating data Materials Operating properties Characteristic Flow rate Head Fluid temperature Hardness of fluid handled Ambient temperature Operating pressure Connection Value Q [m3/h] 0,7 Q [l/s] 0,19 H [m] 1,0 T [ C] +5 to +65 [ dh] 20 T [ C] 0 to +40 p [bar] 10 Calio-Therm S NC: R 1/2 internal thread Calio-Therm S NCV: G 1 1/4 external thread Designation Example: Calio-Therm S NCV S Designation key Code Description Calio-Therm S Type series NCV Design NC Fixed speed 1) 4 Overview of available materials Component Volute casing Shaft Impeller Bearings Can Product benefits Broad product range with many connection options No tools required for connection Easy to operate; operating status displayed High-efficiency pump for maximum energy savings Three speed levels for optimum adaptation to the system Long service life associated with the "Handwerkermarke" trade seal With integrated power cable (2 m length) and shockproof plug (plug type F) Calio-Therm S NC Material Brass CW617N Stainless steel Technopolymer CuSn8, suitable for drinking water Stainless steel , wetted parts polyamide PA6.6

5 Building Services: Heating Drinking Water Circulator Pumps Certifications FluidFuture energy efficiency concept developed by KSB Overview Label Effective in: Germany Comment All sizes Selection information Minimum pressure The minimum pressure pmin at the pump suction nozzle serves to avoid cavitation noises at an ambient temperature of +40 C and the indicated fluid temperature Tmax. The indicated values are applicable up to 300 m above sea level. For installation at altitudes > 300 m, an allowance of 0.01 bar / 100 m must be added. Minimum pressure pmin [bar] specified for the fluid temperature [ C] Size All Fluid temperature [ C] Up to 65 Minimum pressure [bar] 0,4 Overview of product features / selection tables Features and functions Features and functions Functions Features Non-overloading motor Functions Automatic stop when the motor is blocked Operating status indicated by LED Pump fault display (3 flashing LEDs) Calio-Therm S NC 5

6 Building Services: Heating Drinking Water Circulator Pumps Technical data Size Pump connection Enclosure Speed levels P 1 [W] Plug-type connection Connection cable integrated in the pump Mat. No. NC S Rp 1/2 (EN 10266) 2) IP42 3 2,5-8, NC K Rp 1/2 (EN 10266) 2) IP42 3 2,5-8, NCV S G 1 1/4 (DIN ISO 228) 3) IP42 3 2,5-8, ,3 NCV K G 1 1/4 (DIN ISO 228) 3) IP42 3 2,5-8, ,3 [kg] Characteristic curves Calio-Therm S NC Q [US.gpm] Q [IM.gpm] 2 1~230 VAC R 1/ H [m] H [ft] Q [m³/h] Q [l/s] Calio-Therm S NC/0 Calio-Therm S NCV Q [US.gpm] Q [IM.gpm] ~230 VAC R 1 1/ H [m] 0.4 H [ft] Q [m³/h] Q [l/s] Calio-Therm S NCV/0 2) Internal thread 3) External thread 6 Calio-Therm S NC

7 Building Services: Heating Drinking Water Circulator Pumps Dimensions Calio-Therm S NC/NCV Installation information Calio-Therm S NC/NCV ~ Permissible installation positions Sizes Calio-Therm S NC Calio-Therm S NCV ~76 Fig. 1: Dimensions of Calio-Therm S NC S [mm] ~130 The plug-type connection / cable connection integrated in the pump can be fixed in any position (e.g. pointing downward). To this end, loosen the product-integrated union nut and move the pump head (connection housing including motor) into the required position. Then tighten the union nut again. ~ ~76 ~137 Fig. 2: Dimensions of Calio-Therm S NCV S [mm] Scope of supply Depending on the model, the following items are included in the scope of supply: Pump Plug-type connection or integrated, pre-configured connection cable (depending on the size) Installation/operating manual Thermal insulation shells 2 fitted plugs preventing the ingress of foreign matter 65 ~76 ~130 Fig. 3: Dimensions of Calio-Therm S NC K [mm] 110 ~76 ~137 Fig. 4: Dimensions of Calio-Therm S NCV K [mm] Calio-Therm S NC 7

8 Building Services: Heating Drinking Water Circulator Pumps Accessories Electrical accessories Description Mat. No. [kg] Timer ,2 Angular connector, black, with sealed 3-core connection cable mm², length 1.5 m ,015 8 Calio-Therm S NC

9

10

11

12 /03-EN 23/02/2017 KSB Aktiengesellschaft Johann-Klein-Straße Frankenthal (Germany) Tel

Automatic Waste Water Lifting Unit. Ama-Drainer-Box Mini. Type Series Booklet

Automatic Waste Water Lifting Unit. Ama-Drainer-Box Mini. Type Series Booklet Automatic Waste Water Lifting Unit Type Series Booklet Legal information/copyright Type Series Booklet KSB Aktiengesellschaft Pegnitz All rights reserved. Contents provided herein must neither be distributed,

More information

Vertical Ring-section Pump WKTB. Type Series Booklet

Vertical Ring-section Pump WKTB. Type Series Booklet WKTB Type Series Booklet Legal information/copyright Type Series Booklet WKTB All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed for

More information

Cleaning System. Amajet. Type Series Booklet

Cleaning System. Amajet. Type Series Booklet Amajet Type Series Booklet Legal information/copyright Type Series Booklet Amajet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed

More information

mini-compacta Type Series Booklet

mini-compacta Type Series Booklet Floodable Sewage Lifting Unit 60 Hz Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,

More information

GRUNDFOS DATA BOOKLET. Grundfos COMFORT. Circulator pumps. 50/60 Hz

GRUNDFOS DATA BOOKLET. Grundfos COMFORT. Circulator pumps. 50/60 Hz GRUNDFOS DATA BOOKLET Circulator pumps 50/60 Hz 2 Product range 2. Product range UP(S) COMFORT, 50/60 Hz Pump type 24-hour timer Supplied with Dimensions Accessories Data sheet Thermostat Isolating valve

More information

Submersible Waste Water Pump. Ama-Drainer N 301/302/ Hz. Type Series Booklet

Submersible Waste Water Pump. Ama-Drainer N 301/302/ Hz. Type Series Booklet Submersible Waste Water Pump Ama-Drainer N 301/302/303 60 Hz Type Series Booklet Legal information/copyright Type Series Booklet Ama-Drainer N 301/302/303 All rights reserved. The contents provided herein

More information

Submersible Waste Water Pump. Ama-Drainer N 301/302/303/358. Type Series Booklet

Submersible Waste Water Pump. Ama-Drainer N 301/302/303/358. Type Series Booklet Submersible Waste Water Pump Ama-Drainer N 301/302/303/358 Type Series Booklet Legal information/copyright Type Series Booklet Ama-Drainer N 301/302/303/358 All rights reserved. The contents provided herein

More information

Conductivity Electrode LRG Original Installation Instructions English

Conductivity Electrode LRG Original Installation Instructions English Conductivity Electrode LRG 16-4 EN English Original Installation Instructions 818854-02 1 Contents Important notes Page Usage for the intended purpose...4 Function...4 Safety note...5 Directives and standards

More information

KSB mechanical seals for water and waste water applications

KSB mechanical seals for water and waste water applications Our technology. Your success. Pumps n Valves n Service KSB mechanical seals for water and waste water applications 02 Introduction Single-source supplier: your partner for pumps, valves and service We

More information

Multistage Centrifugal Pumps with Shaft Sealing Type HZ / HZA / HZAR

Multistage Centrifugal Pumps with Shaft Sealing Type HZ / HZA / HZAR Multistage Centrifugal Pumps with Shaft Sealing Type HZ / HZA / HZAR General DICKOW-pumps of series HZ/HZA are single- or multistage centrifugal pumps with shaft sealing. Application HZ/HZA-pumps are applied

More information

ASTRO EXPRESS 2 HOT WATER DELIVERY SYSTEM

ASTRO EXPRESS 2 HOT WATER DELIVERY SYSTEM ASTRO EXPRESS 2 HOT WATER DELIVERY SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS File No: 10.817 Date: july 23, 2015 Supersedes: 10.817 Date: june 3, 2015 1.0 Typical installations 1 2.0 How it works

More information

Level Electrode NRG NRG Original Installation Instructions English

Level Electrode NRG NRG Original Installation Instructions English Level Electrode NRG 10-52 NRG 16-52 EN English Original Installation Instructions 819123-02 Contents Important notes Page Usage for the intended purpose...4 Function...4 Safety note...4 Directives and

More information

QVE1901U Flow Switch. Technical Instructions Document No September 20, Description. Features. Application.

QVE1901U Flow Switch. Technical Instructions Document No September 20, Description. Features. Application. Document No. 55-7 September 0, 0 QVE90U Flow Switch Description Flow switch for liquids in piping 3/4-inch to 8-inch (0 mm to 00 mm) diameter Features Application Product Number Contact load/switching

More information

GRUNDFOS DATA BOOKLET MTB. Centrifugal machine tool pumps 50/60 Hz

GRUNDFOS DATA BOOKLET MTB. Centrifugal machine tool pumps 50/60 Hz GRUNDFOS DATA BOOKLET Centrifugal machine tool pumps 5/6 Hz Contents General description Introduction 3 Applications 3 Special features 3 Identification Type key Codes Pump types and data Construction

More information

Installation and instruction manual SOLAR STATION

Installation and instruction manual SOLAR STATION INSTALLATION AND INSTRUCTION MANUAL SOLAR STATION Installation and instruction manual SOLAR STATION SST 25-1E / SST25-2E EN April 2015 1 Table of contents Usage 3 Warranty 3 Safety instructions and symbol

More information

Installation & Operating Instructions

Installation & Operating Instructions GESTRA Steam Systems NRG 16-50S EN English Installation & Operating Instructions 819013-01 Level Electrode NRG 16-50S 1 Contents Important notes Page Usage for the intended purpose...4 Function...4 Safety

More information

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage - Liquid Ring Vacuum Pump One Stage LPH 60527 Pressure Range: Suction Range: 120 to 1013 mbar 200 to 800 m³/h CONSTRUCTION Sterling SIHI liquid ring vacuum pumps have a simple but robust construction with

More information

GRUNDFOS DATA BOOKLET UPS2. Circulator pumps. 50/60 Hz

GRUNDFOS DATA BOOKLET UPS2. Circulator pumps. 50/60 Hz GRUNDFOS DATA BOOKLET UPS2 Circulator pumps 50/60 Hz UPS2 Table of contents 1. Product introduction 3 Type key.................................................................................... 3 Performance

More information

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP DS series Industrial End Suction Pumps ISO/DP 5199 www.sterlingpumps.com.au DS series Capacities from: Heads from: 340 to 5,680 m3/h (1,500 to 25,000 USPGM) 21 to 106 metres (70 to 350 feet) Power range

More information

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage - Liquid Ring Vacuum Pump One Stage LPH 50523 Pressure Range: Suction Range: 120 to 1013 mbar 70 to 500 m³/h CONSTRUCTION Sterling SIHI liquid ring vacuum pumps have a simple but robust construction with

More information

Instruction Manual, Toftejorg Rotary Spray Heads Toftejorg MultiMidget, Toftejorg MultiMagnum

Instruction Manual, Toftejorg Rotary Spray Heads Toftejorg MultiMidget, Toftejorg MultiMagnum Instruction Manual, Toftejorg Rotary Spray Heads Covering Standard version ESE02746EN Date of issue: April 29, 2014 First published: April 29, 2014 Original manual Contents Contents... 1 Toftejorg Rotary

More information

Spandau Pumps. Sealless Immersion Pumps for Industrial Applications. Overwiev of Products

Spandau Pumps. Sealless Immersion Pumps for Industrial Applications. Overwiev of Products Spandau Pumps Overwiev of Products 1-6000-US Sealless Immersion Pumps for Industrial Applications Centrifugal and screw pumps for low-, medium- and high-pressure applications Quality Management DIN EN

More information

HIGH EFFICIENCY CIRCULATORS. Represented by Taconova Group AG CATALOGUE 2018 EN. easyuse. greatperformance

HIGH EFFICIENCY CIRCULATORS. Represented by Taconova Group AG CATALOGUE 2018 EN. easyuse. greatperformance HIGH EFFICIENCY CIRCULATORS Represented by Taconova Group AG CATALOGUE 218 EN easyuse greatperformance CONTENTS WELCOME...3 HEATING SYSTEMS ES2 6...4 ES2 7...6 ES2 C A 6...8 ES2 ADAPT 6...1 ES2 ADAPT 7...12

More information

Building Services. KSB Building Services. A Real Welcome Home.

Building Services. KSB Building Services. A Real Welcome Home. Building Services KSB Building Services. A Real Welcome Home. 2 Introduction Build the future with KSB. Whether you earn your living by installing or selling pumps, valves and systems, or want to make

More information

UPZ PUMP POWER FOR TOP PERFORMANCE UNDER

UPZ PUMP POWER FOR TOP PERFORMANCE UNDER Submersible borehole pump People at KSB we make your world flow round! UPZ PUMP POWER FOR TOP PERFORMANCE UNDER THE TOUGHEST CONDITIONS UPZ is top choice wherever submersible borehole pumps have to satisfy

More information

Mechanical seals external, single or double, to DIN EN 12756

Mechanical seals external, single or double, to DIN EN 12756 INSTALLATION AND OPERATING MANUAL Translation of the original manual Series SCK Bearing pedestal group: 0 Mechanical seals external, single or Keep for future use! This operating manual must be strictly

More information

SL EX.4.51D

SL EX.4.51D GRUNDFOS DATA BOOKLET SL1.1.1.75.EX.4.51D Grundfos pump 962669 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/sl1/962669/sl1-1-1-75-ex-4-51d-c.html

More information

Chemical Pumps Vertical Chemical Pump Type TNP

Chemical Pumps Vertical Chemical Pump Type TNP Chemical Pumps Vertical Chemical Pump Type TNP In PP / PE-UHMW / PVDF Vertical setting depths up to 00 mm Applications Type TNP vertical chemical pumps are specifically designed to handle acids, alkalis

More information

COMPASS HIGH-EFFICIENCY WET-ROTOR CIRCULATORS

COMPASS HIGH-EFFICIENCY WET-ROTOR CIRCULATORS COMPASS HIGH-EFFICIENCY WET-ROTOR CIRCULATORS INSTALLATION AND OPERATING INSTRUCTIONS File No: 10.895 Date: march 8, 014 Supersedes: 10.895 Date: december 10, 013 1.0 Symbols used in this document 1.0

More information

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W 594 59P0 Flow switch for liquids in piping DN 0 00. QE90 Contact load / switching capacity: Nominal pressure PN5 Manual setting of contact type (NO / NC) Housing IP 65 / safety class II Maintenance free

More information

UP/UPS-B/UPN Hot Water Service Circulators

UP/UPS-B/UPN Hot Water Service Circulators UP/UPS-B/UPN Hot Water Service Circulators Visions & Values It is the Vision of the Company to achieve our Corporate Mission by providing quality and innovative products and services that give our customers

More information

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59 SOUND-INSULATED FAN OPERATION MANUAL _v.1(2)-en.indd 1 10.08.2015 15:20:59 CONTENT Introduction 3 General 3 Safety rules 3 Transport and storage requirements 3 Manufacturer's warranty 3 Fan design 4 Delivery

More information

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation Standard Sheet for 6823/ 6824 Edition 1000 (0999) 6823 6824 Special Models 1

More information

APPLICATIONS. For the accelerated circulation of hot water in heating circuits with duty point optimisation

APPLICATIONS. For the accelerated circulation of hot water in heating circuits with duty point optimisation OPERATING RANGE Flow rate of up to m /h Manometric head of up to m Max. operating pressure bar Min. intake pressure, bar at 9 C Water temperature range + at + C * EEI-Part, * for a ambient temperature

More information

Inline-Pumps Type NCV /NCVL

Inline-Pumps Type NCV /NCVL Inline-Pumps Type NCV /NCVL General DICKOW-Inline-Pumps, series NCV / NCVL, have been developed for the chemical, petrochemical and related industries. Since the pumps are installed inline, only a minimum

More information

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with two or three CM, CMV or CR pumps. 50 Hz

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with two or three CM, CMV or CR pumps. 50 Hz GRUNDFOS DATA BOOKLET Grundfos booster systems with two or three CM, CMV or CR pumps 50 Hz Table of contents 1. Product introduction 3 2. Performance range 4 with CM pumps 4 with CMV pumps 4 with CR pumps

More information

NEW Lowara ecocirc PRO The new high efficiency domestic hot water PumPs with automatic air venting function and TheRmaL insulation shell

NEW Lowara ecocirc PRO The new high efficiency domestic hot water PumPs with automatic air venting function and TheRmaL insulation shell NEW Lowara ecocirc PRO The new high efficiency domestic hot water pumps with automatic air venting function and thermal insulation shell ecocirc PRO domestic hot water circulation pumps. Areas of use.

More information

NON-SUBMERSIBLE WATER PUMP

NON-SUBMERSIBLE WATER PUMP NON-SUBMERSIBLE WATER PUMP MODEL NO: CEB103 PART NO: 7230327 OPERATION & MAINTENANCE INSTRUCTIONS LS0114 INTRODUCTION Thank you for purchasing this CLARKE Water Pump, which is a general purpose pump, suitable

More information

Safe, precise and cost-effective dosing with ProMinent Low-pressure dosing pumps up to 1,000 l/h

Safe, precise and cost-effective dosing with ProMinent Low-pressure dosing pumps up to 1,000 l/h Safe, precise and cost-effective dosing with ProMinent Low-pressure dosing pumps up to 1,000 l/h Printed in Germany, PT PM 054 09/06 GB MT20 01 01/06 GB Solenoid and motor-driven diaphragm dosing pumps

More information

SOUTH AFRICAN NATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD ISBN 978-0-626-28897-6 IEC 61869-1:2007 SOUTH AFRICAN NATIONAL STANDARD Instrument transformers Part 1: General requirements This national standard is the identical implementation of IEC 61869-1:2007 and

More information

TP /4-A-F-A-BQQE 400D 50HZ

TP /4-A-F-A-BQQE 400D 50HZ GRUNDFOS DATA BOOKLET TP 15-7/-A-F-A-BQQE D 5HZ Grundfos pump 989838 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tp/989838/tp-15-7--a-f-a-bqqe.html

More information

LC3000 Level Controller Installation and Maintenance Instructions

LC3000 Level Controller Installation and Maintenance Instructions 4025550/12 IM-P402-36 AB Issue 12 LC3000 Level Controller Installation and Maintenance Instructions 1. General safety information LC3000 NORM ALARM TEST 2. General product information 3. Installation 4.

More information

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems.

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems. Issued 2006/08/01 Section 15131 Pumps Hydronic Systems Page 1 of 6 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal.3 Section 01780

More information

INSTRUCTION MANUAL MM-601REVI. Series FS4-3 General Purpose Liquid Flow Switch

INSTRUCTION MANUAL MM-601REVI. Series FS4-3 General Purpose Liquid Flow Switch INSTRUCTION MANUAL MM-601REVI 246796 Series FS4-3 General Purpose Liquid Flow Switch SPECIFICATIONS Maximum Liquid Pressure: 160 psi (11.3 kg/cm 2 ) Liquid Temperature Range (TL): 32-300 F (0-149 C) Ambient

More information

UV Flame Supervision System

UV Flame Supervision System 7 783 UV Flame Supervision System DETACTOGYR LFE50 Series 02 ISO 9001 The LFE50 is a self-checking UV flame supervision system designed for use with continuously operating burners or for burners running

More information

1592P01. for liquids in piping DN

1592P01. for liquids in piping DN 1 594 1592P01 Flow switch for liquids in piping DN 20 200. QVE1901 Contact load / switching capacity: max. AC 230 V, 1 A, 26 VA max. DC 48 V, 1 A, 20 W Nominal pressure PN25 Manual setting of contact type

More information

GMA Panels with double busbar

GMA Panels with double busbar L1 L2 L3 GAS-INSULATED SWITCHGEAR >> GMA Panels with double busbar Operating Instructions No. AGS 532 521-01 Edition 09/07 (Supplement to Operating Instructions AGS 531 521-01) Technical Instructions AREVA

More information

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL 216300-000 rev2 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM FOR HAZARDOUS LOCATIONS MODEL OSE OSX (this page intentionally left blank) IDENTIFYING YOUR SYSTEM IOM216300-000 The HOTSTART

More information

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2 INTEGRA PLUS Installation and Wiring Instructions Stock Ref. N INTEGRA PLUS 437666 230V~ 50Hz ABC PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS. IPX2 VENT-AXIA

More information

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2 Cleaning unit for coolant :_decftez`_>r_fr] Book No.: 1271526-02 V2 Alfa Laval Separation AB Separator Manuals, dept. SKEL S-147 80 Tumba, Sweden Telephone: +46 8 53 06 50 00 Telefax: +46 8 53 03 10 40

More information

Montageanleitung RLO (Original) Mounting Instructions RLO (Translation of the original)

Montageanleitung RLO (Original) Mounting Instructions RLO (Translation of the original) Montageanleitung (Original) (Translation of the original) DE MA_ 1.0 06/2014 Taperlock Clamping-bush system _0 _1 Fixed hub Inlet nozzle with IMV 1. Revision index Revision Date MA_ 1.0 06/2014 2. Safety

More information

FSW300 Series Flow Switch

FSW300 Series Flow Switch . FSW300 Series Flow Switch - 2 - Series FSW300 Series FSW300 Table of contents page 0 About this operating manual... 4 1 Device description... 5 1.1 Intended use... 5 1.1.1 Reed contact - Switching of

More information

Astro Express 2 - Hot Water Delivery System

Astro Express 2 - Hot Water Delivery System FILE NO.: 10.817 DATE: Apr. 4, 2011 SUPERSEDES: 10.817 DATE: Feb. 24, 2010 INSTALLATION AND OPERATING INSTRUCTIONS Astro Express 2 - Hot Water Delivery System TYPICAL APPLICATIONS The Armstrong Astro Express

More information

PRIUX HOME D. High-efficiency double circulating pumps Heating Air conditioning 50 Hz OPERATING RANGE APPLICATIONS BENEFITS

PRIUX HOME D. High-efficiency double circulating pumps Heating Air conditioning 50 Hz OPERATING RANGE APPLICATIONS BENEFITS OPERATING RANGE Flow rate of up to 7 m /h* Manometric head of up to 8 mwc Max. operating pressure bar Min. suction pressure, bar at 9C Temperature range -C at 9C Max. ambient temperature +C EEI-Part Priux

More information

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P Contents Description Data Sheet No. Page Overview P-1.50.001E 117-118 Technical Data SFI-plus P-1.50.002E-1, 2 119-120 Dimensions

More information

Level Electrode NRG Original Installation Instructions English

Level Electrode NRG Original Installation Instructions English Level Electrode NRG 16-36 EN English Original Installation Instructions 819257-01 Contents Contents Page Important notes Usage for the intended purpose...4 Function...4 Safety note...4 Directives and standards

More information

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve Connection and energy management compact unit 2850 series ACCREDITED CALEFFI 01259/14 GB ISO 9001 FM 21654 ISO 9001 No. 0003 Function The connection and energy management compact unit enables combining

More information

! WARNING. Before using product, read and understand instructions.

! WARNING. Before using product, read and understand instructions. Installation & Maintenance Instructions MM-60C) Series FS4-3 General Purpose Liquid Flow Switch specified models only) Now with Stainless Steel Paddles OPERATION This control is an independently mounted

More information

CRU-S Series Stainless Steel Condensate Recovery Unit

CRU-S Series Stainless Steel Condensate Recovery Unit IM-UK-CRU-S UK Issue 1 CRU-S Series Stainless Steel Condensate Recovery Unit 1. Safety information 2. General product information 3. Installation 4. Commissioning 5. Storage, shutdown and equipment protection

More information

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

4VH and 4VHX. 4 Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction 4VH and 4VHX 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction DURABLE MOTOR WILL DELIVER MANY YEARS OF RELIABLE SERVICE Oil-filled motor for maximum heat dissipation

More information

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation. Brochure# 228E 122011 TYPE VSA SEWAGE PUMP Capacities to 100 gpm, Heads to 120, Horsepower range 3/ thru 0, 3 thru discharge, 1750 and 1150 operation. HIGHLIGHTS Wet-Pit Installations Pumps Suspend From

More information

AlertMaxx2. Installation & Operating Manual. Ground Water (DMS-298) Pump Station High Level Alarm

AlertMaxx2. Installation & Operating Manual. Ground Water (DMS-298) Pump Station High Level Alarm Ground Water (DMS-298) Installation & Operating Manual Pump Station High Level Alarm T. E. W. 01992 523 523 info@deltamembranes.com www.deltamembranes.com Delta House, Merlin Way, North Weald, Epping,

More information

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM 216279-000 rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM IDENTIFYING YOUR SYSTEM IOM216279-000 The HOTSTART heating system is designed to heat fluids for use in marine

More information

KUBOTA Double suction volute pump

KUBOTA Double suction volute pump PUMPS CATALOGUE KUBOTA Double suction volute pump DV-L type J series KUBOTA Corporation DOMESTIC OFFICES AND OVERSEAS OFFICE E-Mail:pump@kubota.co.jp http://www.kubota.co.jp/english KUBOTA Double suction

More information

EN Instruction manual

EN Instruction manual EN Instruction manual For laboratory use. Flaming from any angle. DIN 30665, part 1 1 Overview 1 - Gas adjustment 2 - Status - LED 3 - Burner tube 4 - Flame orifice 5 - Connector for foot pedal 6 - Gas

More information

Circulation pumps. Wet rotor circulators and accessories. Heating Potable water Solar Geothermy Condensate

Circulation pumps. Wet rotor circulators and accessories. Heating Potable water Solar Geothermy Condensate Circulation pumps Wet rotor circulators and accessories eating Potable water Solar Geothermy Condensate CATALOGUE / alm produces highly-efficient heating circulation pumps alm has been successfully developing

More information

LPC3BSP65 & LPC3BDP65

LPC3BSP65 & LPC3BDP65 Product Guide LPC3BSP65 & LPC3BDP65 Batten mount PIR detectors Overview The LPC3B series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional

More information

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air Document No. 155-755 Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air Description Features Application The Q-Series Relative Humidity and

More information

Electronic Standard Devices. Annunciator Relay. MR 11 and MRE 11 MR 21 and MRE 21

Electronic Standard Devices. Annunciator Relay. MR 11 and MRE 11 MR 21 and MRE 21 Electronic Standard Devices Annunciator Relay MR and MRE MR 2 and MRE 2 The products described in this brochure are intended for industrial use and meet the requirements laid down by the EU directive 7

More information

High-efficiency circulating pumps Heating Air conditioning 50 Hz

High-efficiency circulating pumps Heating Air conditioning 50 Hz OPERATING RANGE Flow rate of up to m /h Manometric head of up to 8 mwc Max. operating pressure bar Min. suction pressure, bar at 9 C Temperature range - C at 9 C Max. ambient temperature + C EEI-Part,

More information

GESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45

GESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45 GESTRA Steam Systems DK 45 EN English Installation Instructions 818676-00 Steam Trap DK 45 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 Danger...4 Attention...4 PED

More information

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50 Differential Pressure and Flow Meter Media 5 Indicator 160 Ø PN 50 Application Transmitter for measuring and indicating the differential pressure or measured variables derived from it Suitable for gases

More information

Gas cylinder scale Model GCS-1

Gas cylinder scale Model GCS-1 Electronic pressure measurement Gas cylinder scale Model GCS-1 WIKA data sheet PE 87.19 Applications Level measurement of liquid gases in gas cabinets and gas distribution systems Level measurement in

More information

Blockpumps. Vogel Series LSB. Lenntech. Tel Fax

Blockpumps. Vogel Series LSB. Lenntech. Tel Fax Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Blockpumps Vogel Series LSB WITH HYDRAULICS ACCORDING TO ISO 2858 Technical Data Performance: m Capacity up to 450m

More information

PROFIBUS-PA Display RID 261 PROFIBUS-PA

PROFIBUS-PA Display RID 261 PROFIBUS-PA Technical Information TI 071R/09/en Mat.-Nr.: 510 01194 PROFIBUS-PA Display RID 261 PROFIBUS-PA Display of process values and set point alarms on PROFIBUS-PA systems R Applications Direct connection to

More information

HTM Circulation Pumps acc. to DIN EN 733 Type NKX

HTM Circulation Pumps acc. to DIN EN 733 Type NKX HTM Circulation Pumps acc. to DIN EN 733 Type NKX General The new NKX pump line replaces our former heat transfer oil circulation pump type NKL s. The outer dimensions of both pump types are identical

More information

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with 2 or 3 CM, CMV or CR pumps 50 Hz

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with 2 or 3 CM, CMV or CR pumps 50 Hz GRUNDFOS DATA BOOKLET Grundfos booster systems with 2 or 3 CM, CMV or CR pumps 50 Hz Table of contents 1. Product data 3 Introduction 3 Performance range 4 Product range 6 Type key 9 Operating conditions

More information

Temperature Sensor TRG Original Installation Instructions English

Temperature Sensor TRG Original Installation Instructions English Temperature Sensor TRG 5-6.. EN English Original Installation Instructions 818597-05 1 Contents Important notes Page Usage for the intended purpose...4 Function...4 Safety note...4 Directives and standards

More information

Modular standard power units. Type ABSKG. Contents. Features. RE Edition: Replaces: Tank size 20, 40 and 60 liters

Modular standard power units. Type ABSKG. Contents. Features. RE Edition: Replaces: Tank size 20, 40 and 60 liters Modular standard power units Type ABSKG RE 51013 Edition: 09.13 Replaces: 04.06 Tank size 20, 40 and 60 liters Contents Features ABSKG-40_001_d Stable aluminum tank Modular design Compact power unit design

More information

SL S.S.N.51D

SL S.S.N.51D GRUNDFOS DATA BOOKLET SL1.8..265.2.52S.S.N.51D Grundfos Pump 9814549 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/seslfam/9814549/sl1-8--265-2-52s-s-n-51d.html

More information

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI Hydraulic Institute Standards. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

INSTRUCTION MANUAL A131 High Level Audible Warning System / Battery backup

INSTRUCTION MANUAL A131 High Level Audible Warning System / Battery backup 115 or 230VAC (90V to 264V AC range) Operating Temp: -20 to +55 C IP Rating: IP66 Weight: 5.5 kg single AC unit 7.0 kg four way AC unit Marking: Installation Requirements 1) Introduction The A131 high

More information

CAP SERIES SEWAGE AND WASTE WATER PUMPS

CAP SERIES SEWAGE AND WASTE WATER PUMPS Part 8 CAP SERIES SEWAGE AND WASTE WATER PUMPS TECHNICAL SPECIFICATIONS : Turbosan CAP series consists of centrifugal sewage and waste water pumps. They are used for pumping muddy liquids like sewage and

More information

ACS-30-EU-EMDR- 10-MOD

ACS-30-EU-EMDR- 10-MOD ACS-30-EU-EMDR- 10-MOD MULTI-APPLICATION HEAT TRACING CONTROL AND MONITORING IN COMMERCIAL AND RESIDENTIAL BUILDINGS ROOF & GUTTER DE-ICING SENSOR MODULE TECHNICAL INFORMATION DESCRIPTION The nvent RAYCHEM

More information

hygienic design CLEANLINESS MADE TO MEASURE: HYGIENIC DESIGN FANS

hygienic design CLEANLINESS MADE TO MEASURE: HYGIENIC DESIGN FANS hygienic design G R O U P CLEANLINESS MADE TO MEASURE: HYGIENIC DESIGN FANS EHEDG member PIONEERING CONSISTENT HYGIENE. Microbial contaminations represent a constant risk in food production for consumers

More information

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals. SECTION 23 21 23 - HYDRONIC PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

CALEFFI. Anti-condensation recirculation and distribution unit. 281 series 01224/14 GB. Replaces dp 01224/12 GB. Function

CALEFFI. Anti-condensation recirculation and distribution unit. 281 series 01224/14 GB. Replaces dp 01224/12 GB. Function Anti-condensation recirculation and distribution unit 8 series ACCREDITED ISO 900 FM 654 ISO 900 No. 000 CALEFFI 04/4 GB Replaces dp 04/ GB GB Function The anti-condensation recirculation and distribution

More information

VADA - V80-H PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

VADA - V80-H PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY PRODUCT OVERVIEW The VADA horizontal multistage centrifugal pumps combine the functional benefits of centrifugal pumps and the practical benefits of self priming pumps. They warrant high hydraulic and

More information

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 EN OPERATION MANUAL CONTENTS Introduction 3 General 3 Safety rules 3 Transportation and storage rules 3 Manufacturer's warranty 3

More information

CRU 200 and 500 Series Condensate Recovery Unit Installation and Maintenance Instructions

CRU 200 and 500 Series Condensate Recovery Unit Installation and Maintenance Instructions 6810850/1 IM-P681-07 ST Issue 1 CRU 200 and 500 Series Condensate Recovery Unit Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning

More information

Vacuum suction nozzle OVEM-...-1P/1N

Vacuum suction nozzle OVEM-...-1P/1N Vacuum suction nozzle OVEM-...-1P/1N Operating instructions (Translation of the original instructions) Festo AG & Co. KG Ruiter Straße 82 73734 Esslingen Germany +49 711 347-0 www.festo.com 8085608 2018-01b

More information

V80-H Multistage Pump Instruction Manual

V80-H Multistage Pump Instruction Manual V80-H Multistage Pump Instruction Manual PRODUCT OVERVIEW The VADA horizontal multistage centrifugal pumps combine the functional benefits of centrifugal pumps and the practical benefits of self priming

More information

LS Condensate Removal Pump INSTRUCTION MANUAL REVISION A

LS Condensate Removal Pump INSTRUCTION MANUAL REVISION A LS Condensate Removal Pump INSTRUCTION MANUAL 6-71-075-115 REVISION A CAUTION: Combustible liquids may not be pumped! The condensate pump may not be run dry, as this can destroy the bearings in a very

More information

Sealless Immersion Pumps for Industrial Applications

Sealless Immersion Pumps for Industrial Applications Overview of Products 16000EN Sealless Immersion Pumps for Industrial Applications Centrifugal and screw pumps for low, medium and highpressure applications Quality Management DIN EN ISO 9001:2008 www.spandaupumpen.comau

More information

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. VA100 Lo-Carbon RANGE 100mm AXIAL EXTRACT FAN Installation and Wiring Instructions Stock Ref. N 44 31 59 - LP 44 31 60 - XP 44 31 61 - LT 44 31 62 - XT 44 31 63 - LHTP 44 31 64 - XHTP 220-240V~50Hz PLEASE

More information

Submersible. Pumps Motors. 50Hz 12 Submersible Pump. Pumping Solution

Submersible. Pumps Motors. 50Hz 12 Submersible Pump. Pumping Solution Submersible Pumps Motors 50Hz 2 Submersible Pump Pumping Solution 65 Product data 2 Submersible bore well pumps Construction Submersible motor & pumps for deep wells of 2 (DN 300 mm). Sized for connection

More information

Cooling Fans ver ver.4

Cooling Fans ver ver.4 H Cooling Cooling H-1 Overview of Cooling... H-2 Overview Axial... H-13 Low-Power Consumption EMU Series H-18 Axial Low-Power Consumption EMU MU Series H-20 Large Size, Large Air MRS Series H-22 MRE Series

More information

TRG 5-53 TRG 5-54 TRG 5-55 TRG 5-57

TRG 5-53 TRG 5-54 TRG 5-55 TRG 5-57 GESTRA GESTRA Steam Systems TRG 5-53 TRG 5-54 TRG 5-55 TRG 5-57 EN English Installation & Operating Instructions 810428-05 Temperature Sensor TRG 5-53, TRG 5-54, TRG 5-55, TRG 5-57 1 Contents Application

More information

15-BER3. parts list as Excel-spreadsheet. Tsurumi Europe GmbH

15-BER3. parts list as Excel-spreadsheet. Tsurumi Europe GmbH 5-BER3 data sheet parts list exploded view dimensional drawing free standing type dimensional drawing TOS-type sectional drawing free standing type sectional drawing TOS-type performance curve parts list

More information

Condensate Monitor CGKW. Operator s Manual 42/23-36 EN Rev. 2

Condensate Monitor CGKW. Operator s Manual 42/23-36 EN Rev. 2 Condensate Monitor CGKW Operator s Manual 42/23-36 EN Rev. 2 Parts Supplied with the Unit Qty. Description 1 Mounting bracket 2 Nozzles G1/4 2 O-rings for nozzles 25 Filter membranes (of glass fibre) Examples

More information