Thermostats. Type Voltage Max. current Setting range Protection class HxWxD breakpoint [V] [A] [ C] [mm] RTEV C IP30 71x71x28
|
|
- Quentin Haynes
- 5 years ago
- Views:
Transcription
1 Thermostats RTE 0/0 RTEV 0/0/0V RTEV 0/0 RTEV 0 Electronic thermostats Setting of temperature on the RTE 0/0 is done on the circuit board under the housing to prevent unauthorised persons from changing the selected temperature. Thermostats are designed to control heat directly or to be used as sensors in larger centrally controlled facilities. RTEV 0/0 is equipped with a dial for setting the temperature. The setting range can be limited on the back of the dial and the thermostat can be calibrated there as well, if necessary. RTEV 0V is also equipped with an alternating relay and can therefore be used for the regulation of heating or cooling. External sensors mounted in ventilation ducts or the floor can also be connected. RTEV 0/0 has a function switch for on/off connection as well as the optional connection of external sensors. A fixed temperature reduction of ºC can be activated by an externally connected contact, such as a weekly timer. The setting range can be limited and calibrated on the setting dial. RTEV 0 also has a built-in clock function in addition to the dial and the option of connecting external duct or floor sensors. The period for temperature reduction by ºC is, 7,, or 6 hours. The preferred period is set on the circuit board upon installation. The reduction period is activated by pushing the start button at the desired time of day. The clock is then set and the reduction period starts at that time every day automatically. An ongoing temperature reduction period can be interrupted with a push of the start button. The following day, the reduction period once again begins at the usual set time. Type Voltage Max. current Setting range rotection class HxWxD breakpoint [V] [A] [ C] [mm] RTE C 7x7x8 RTE C 7x7x8 RTEV C 7x7x8 RTEV C 7x7x8 RTEV0V C 7x7x8 RTEV C 7x7x8 RTEV C 7x7x8 RTEV C 7x7x8 8 Frico AB, Box 0, SE- artille Tel: Fax: mailbox@frico.se
2 KRT900/90 KRTV9 KRTE Capsulated Thermostats Capillary tube thermostats and electrical thermostats with alternating contacts Capillary tube thermostats with alternating contacts for the control of heaters and fans. The housing is of thermal plastic. Convertible between 0/00 V and approved for 6 A at 0 V and 0 A at 00 V. KRT 900/90 both have internal dials but have different setting ranges. KRTV 9 has an external dial with an adjustable stop for the imum setting. Electronic thermostats are not subject to mechanical wear. Thus, they are very reliable and have longer durability. A sensor on a metres long cable is included with the KRTE thermostat. The sensor can be placed anywhere or fixed directly on the thermostat. The cable is easily extendable. The KRTE has an alternating contact and is approved for 0A at 0V. Type Voltage Setting range rotection class HxWxD KRT900 0/ C I 6x7x60 KRT90 0/ C I 6x7x60 KRTV9 0/ C I 6x7x60 KRTE C I 6x7x60 Frico AB, Box 0, SE- artille Tel: Fax: mailbox@frico.se 9
3 KRT stage thermostats, capillary tube -stage regulation is appropriate for the soft and economical control of heating output in e.g. fan heaters and air curtains. There are two types to choose from: KRT 800 with an adjustable temperature difference between the stages ( - C). 000 with a fixed temperature difference ( C) between the stages. Both are convertible between 0/00V and approved for 6A at 0V and 0A at 00V. Type Voltage Setting range rotection class HxWxD KRT800 0/ C I 6x7x / C I x00x7 RTI -stage thermostat, electronic -stage thermostat with internal setting. Adjustable temperature difference between the stages ( 0 C). Type Voltage Setting range rotection class HxWxD RTI 0/ C I 0x80x0 0 Frico AB, Box 0, SE- artille Tel: Fax: mailbox@frico.se
4 WIRIG DIAGRAMS THERMOSTATS Internal wiring diagrams RTE 0 0V~ L 00V~ L RTE 0 RTE(V)0 A RTE(V)0 8 A RTEV 0 RTEV 0 RTEV 0V 6 RTEV0V Cool 0V~ Heat A RTEV 0 RTEV0 0V~ A 6 h h 0V~ RTEV 0 7 h h RTEV0 A Ext. sensor RTEV 0 RTEV0 L 00V~ L 8 A Frico AB, Box 0, SE- artille Tel: Fax: mailbox@frico.se
5 WIRIG DIAGRAMS THERMOSTATS Internal wiring diagrams KRT(V) 9(00) 6A 0V~ /0A 00V~ KRTE 0A 0V~ /6A 00V~ <ϑ 0V~ KRT900 A B KRTE TC KRTV9 L L () L L ( ) KRT 800, 6A 0V~ /0A 00V~ 000 0A 0/ 00 V~ KRT L L () L L () RTI 6A 0V~ /0A 00V~ <J <J 0V~ RTI L 6 7 L L ( ) Frico AB, Box 0, SE- artille Tel: Fax: mailbox@frico.se
Fan heater Panther Powerful fan heater for large premises
3 20 30 Electrical heat 5 models Fan heater Panther 20-30 Powerful fan heater for large premises Application Panther 20 30 is a range of powerful and quiet fan heaters for stationary use. They are intended
More informationIndustrial infrared heater IR For premises with large volumes and high ceilings
Electrically heated 3000 6000 W 3 models Industrial infrared heater For premises with large volumes and high ceilings Application is suitabe for total or supplementary heating of premises with large volume
More informationThermocassette HP RADIANT HEAT CASSETTES FOR CEILING MOUNTING
Electrical heat 300 600 W Thermocassette RADIANT HEAT CASSETTES FOR CEILING MOUNTING 10 models Radiant heater Thermocassette is appropriate for heating of rooms with ceiling heights up to 3 metres where
More informationOriginal instructions. Panther 6-15 kw
Original instructions 6-15 kw SE... 8 GB... 10 NL... 12 IT... 14 ES... 16 FI... 18 DE... 20 FR... 22 NO... 24 RU... 26 PL... 28 6/15 Fig 1. Bracket 100 ø7 520 90 ø6,5 ø14 450 510 Fig 2. Ceiling Wall 30
More informationSIRe Basic Air Curtains Electric With quick guide. SIReB. For wiring diagram, please see p Original instructions
Original instructions SIRe Basic Air Curtains Electric With quick guide SIReB C SE... 2 GB... 11 DE... 20 FR... 30 For wiring diagram, please see p. 40-42 For more languages, please see www.frico.se SIRe
More informationFan heater Panther WALL MOUNTED FAN HEATER
Electrical heat 6 30 Fan heater WALL MOUNTED FAN HEATER 8 models is a range of silent and efficient fan heaters for fixed installation. is available in two sizes with different outputs. 6 15 is designed
More informationFan Heater SW02 Quiet fan heater for connection to water in small buildings
heat model Heater Quiet fan heater for connection to water in small buildings Application is a compact fan heater with very low sound level designed for water connection. It is ideal for use where fan
More informationOriginal instructions. SIRe Basic Quick guide. SIReB
Original instructions Quick guide SIReB C SE... 7... 14 DE... 21 ES...28 FR... 35 IT... 42 NL...49 NO... 56 PL... 63 RU... 70 FI... 77 Wiring diagram - Basic SIReB SIReB1/B2/B1EC 230V~ SD230 SIReRTX (optional)
More informationFan heater SWT Ceiling mounted fan heater with water heat
Fan heater heat 3 models Fan heater Ceiling mounted fan heater with water heat Application The fan heater is used for heating entrances, stores, industrial premises, workshops, sports halls, garages and
More informationSIRe Advanced Air Curtains Electric With quick guide. SIReAA GB DE FR For wiring diagram, please see last pages. ES
Original instructions SIRe Advanced Air Curtains Electric With quick guide SIReAA SE... 2 GB... 22 DE... 42 FR... 62 ES... 82 IT... 102 NL... 122 NO... 142 PL... 162 RU... 181 For wiring diagram, please
More informationOriginal instructions. Infrared heater IRCF...17
Original instructions Infrared heater SE...7 NO...9 GB...11 DE...13 FR...15 RU...17 Fig. 1 Fig. 2 2 Fig. 3 3 Technical specifications Infrared heater 3 Type Heat output (1) [W] Voltage (2) Amperage (3)
More informationMini Catalogue air curtains radiant heaters fan heaters convectors controls
Mini Catalogue 2007 air curtains radiant heaters fan heaters convectors controls 2007 Contents Frico 4 Thermozone Air curtains Introduction 6 Thermozone guidelines 7 Thermozone AD 100, ADA 10 Thermozone
More informationSIRe Competent Air Curtains Water With quick guide. SIReAC. For wiring diagram, please see p Original instructions
Original instructions SIRe Competent Air Curtains Water With quick guide SIReAC SE... 2 GB... 19 DE... 36 FR... 54 For wiring diagram, please see p.71-73 For more languages, please see www.frico.se SIRe
More informationThermocassette HP SE... 6 GB... 8 NO FR DE FI RU... 18
Thermocassette SE... 6 GB... 8 NO... 10 FR... 12 DE... 14 FI... 16 RU... 18 Thermocassette 305 False ceiling 300/600 605 Minimum mounting distance Min.distance [mm] Ceiling 80 Wall, long side of the unit
More informationOriginal instructions. Thermoplus PL RU
Original instructions SE... 7... 17 NO... 27 FR... 37 ES... 47 DE... 57 FI... 67 IT... 77 NL... 87 PL... 97 RU... 107 EC ECV/ECVTN ø22 (2x) Type A [mm] B [mm] EC450 1076 600 EC600 1505 900 EC750 1810 1200
More informationElztrip EZ100 Single panel radiant heater for offices, shops etc.
600-1500 W Electrical heat 3 models Single panel radiant heater for offices, shops etc. Application 00 is intended for total and supplementary heating as well as protection against cold draughts from windows
More informationFan heater Panther 6-15 Efficient fan heater for medium size premises
Fan Heater 6-15 3 6 15 kw Riscaldamento elettrico 5 modelli Fan heater 6-15 Efficient fan heater for medium size premises Applicazioni 6-15 è una gamma di termoventilatori molto silenziosa ed efficiente
More informationOriginal instructions. Thermoplus
Original instructions Thermoplus SE... 6 GB... 8 NO... 10 FR... 12 DE... 14 FI... 16 IT... 18 NL... 20 RU... 22 Thermoplus Thermoplus EC Thermoplus ECV Type A B EC450 1076 600 EC600 1505 900 EC750 1810
More informationSIRe Advanced Air Curtains Water Ambient, no heat
Original instructions SIRe Advanced Air Curtains Water Ambient, no heat With quick guide SIReAA SE... 2 GB... 23 DE... 44 FR... 65 ES... 86 IT... 107 NL... 128 NO... 149 PL... 170 RU... 191 For wiring
More informationS A U N A S S H O W E R S S T E A M B A T H S TYLO par Lavudson Sauna Page 1 sur 8
S A U N A S S H O W E R S S T E A M B A T H S TYLO par Lavudson Sauna www.lavudson.net Page 1 sur 8 TYLO par Lavudson Sauna www.lavudson.net Page 2 sur 8 Classic Tylö sauna heaters for professional facilities.
More informationOriginal instructions AR
Original instructions SE... 8 GB... 22 NO... 27 FR... DE... 6 ES... 4 NL... 46 IT... 5 RU... 56 Dimensions and connections AR20/AR25 M8 002/52 940/450 494 449 92 20 98 042/552 42 20 AR20/25A/E 40 275 DN5
More informationThermozone AC 300/WAC 300
Ambient, no heat Electrical heat 8- kw Hot water heat Lengths: and.7 metres Thermozone AC 00/WAC 00 AIR CURTAINS FOR DOORWAYS BETWEEN.5 AND.5 METRES The Thermozone 00-series consists of the AC variant
More informationOriginal instructions SWX C/D NO DE ES... 26
Original instructions SE... 10 GB... 14 O... 18 DE... 22 ES... 26 FR... 30 IT... 34... 38 P... 42 RU... 46 150 A E B G ØI F C H D [mm] A B C D E F G H ØI SWX C12/D13 585 535 455 705 R3/4" 250 330 410 10
More informationIndustrial infrared heater IR
Industrial infrared heater For premises with large volumes and high ceilings 3 models 3 3000 6000 W Application is suitabe for total or supplementary heating of premises with large volume and high ceilings.
More informationElztrip EZ100. Elztrip EZ100. Single panel radiant heater for offices, shops etc. Product specifications
Single panel radiant heater for offices, shops etc. 3 models 3 600 1500 W Application 00 is intended for total and supplementary heating as well as protection against cold draughts from windows in environments
More informationSPECIFICATIONS for AIR CONDITIONING CONTROLLER ZONE CONTROL
SPECIFICATIONS for AIR CONDITIONING CONTROLLER ZONE CONTROL 1. INTROUCTION Zone control is a two pieces fan coil thermostat available for Heat/Cool versions. Its application is for the duct type system
More informationThermozone SF. Air curtains for vertical mounting in curved doorways
Electrically heated Water heated Thermozone SF Air curtains for vertical mounting in curved doorways Thermozone SF is an ideal solution for any environment with revolving doors or curved sliders. The air
More informationRadiant heaters - Offices, shops and public premises
Radiant heaters - Offices, shops and public premises Comfort Panel SZR recessed, water heated Comfort Panel SZR can be used for heating or cooling in buildings where water is the heating/cooling medium
More informationSWS SE GB NO DE ES FR IT NL PL RU... 49
SE... 17 GB... 20 O... 23 DE... 26 ES... 30 FR... 34 IT... 38... 42 P... 46 RU... 49 Fan heater 1 Fan heater 2 Mounting brackets SWB 3 Basic filter FT 4 Filter section, deep-pleated bagfilter EU3 SWF 5
More informationThermozone ADR 200/300 E/W
R Thermozone ADR 200/300 E/W Electrical heat 9-18 kw Water heat Lengths: 1, 1,5 and 2 metres Thermozone ADR 200/300 E/W Recessed air curtains for doors heights up to 3,5 metres ADR is our air curtain for
More informationMAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating
MAKING MODERN LIVING POSSIBLE TP7001 Range Electronic 7 Day Programmable Room Thermostat Danfoss Heating User Guide TP7001 Electronic 7 Day Programmable Room Thermostat For a large print version of these
More informationINSTALLATION INSTRUCTIONS FOR USE CC 20
L INSTALLATION Read these instructions together with the assembly instructions that are included with your sauna heater or steam generator. Fig. A TYLARIUM. (Sauna heater type SK, SDK, Deluxe and steam
More informationInverter Ducted Air Conditioners
Inverter Ducted Air Conditioners About Carrier inverter ducted systems Carrier s Inverter Ducted systems allows you to air condition your home without having to install the indoor units on your wall, making
More informationAquastats. Aquatrol Indoor/Outdoor Control. Automatic Changeover Switch 16/05/08
16/05/08 Aquatrol Indoor/Outdoor Control B3 Adjustable settings for boiler maximum temperature, boiler minimum temperature and outdoor low (design) temperature Selectable Warm Weather Shut Down (WWSD)
More informationOriginal instructions. SIRe Basic Fan Heaters Electric With quick guide. SIReBX. For wiring diagram, please see last pages.
Original instructions SIRe Basic Fan Heaters Electric With quick guide SIReBX C For wiring diagram, please see last pages. Quick guide/start up Check that all constituent parts are present (see section
More informationELECTRIC AIR HEATER INSTALLATION AND SERVICE MANUAL
ELECTRIC AIR HEATER INSTALLATION AND SERVICE MANUAL BC(E) SERIES INDOOR / OUTDOOR MANUFACTURED BY GENERAL INFORMATION PROJECT: ADDRESS: MODEL: SERIAL NUMBER: INSTALLER: ADDRESS: TELEPHONE: INSTALLATION
More informationSAT- 3 Installation Setup Guide
SAT- 3 Installation Setup Guide Date: 4 February 2016 Issue: 2 Applies to: SAT- 3 room temperature controller, part number 201-000- 146 Contents 1. Quick Start Guide...2 1.1. General... 2 1.1.1. Installation
More informationERV-24. Technician Settings & Operating Manual. Protected by one or more of the following patents: US 5,547,017; 5,881,806; 6,431,268; CA 2,245,135
ERV-24 Technician Settings & Operating Manual Protected by one or more of the following patents: US 5,547,017; 5,881,806; 6,431,268; CA 2,245,135 1 Introduction brief description General The ERV-24-HC11
More informationOriginal instructions. PF Smart... 60
Original instructions F Smart SE... 9 GB... 19 NO... 28 DE... 38 FR... 49 NL... 60 FS SE Introduktionssidorna består huvudsakligen av bilder. För översättning av de engelska texter som används, se respektive
More informationEXT-CFU-230-D.. Touch Keypad Thermostat
EXT-CFU-30-D.. Touch Keypad fan coil unit thermostats are designed to control the room temperature in air-conditioning fan coil unit system or dust pipe channel system. EXT-CFU-30-D.. thermostats with
More informationThermozone AD Corinte
R Thermozone AD Corinte Ambient, no heat Electrical heat 15 22,5 kw Water heat Vertical: 2,2 and 2,5 metres Horizontal: 1,7 and 2,2 metres Thermozone AD Corinte Air curtains for doors with heights of up
More informationSMARTELEC 2 ENERGY SAVING CONTROL INSTALLATION AND OPERATING MANUAL
Instruction Manual. SMARTELEC 2 SmartElec ENERGY SAVING CONTROL INSTALLATION AND OPERATING MANUAL 0 F1 INDEX Section General information ------------------------------------------------------------ 1 Dimensions
More informationToll Free: Tel: Fax:
Toll Free: 1-888-865-6888 Tel: 510-226-8368 Fax: 510-226-8968 Email: sales@rackmountmart.com Copyright 2015 Synergy Global Technology Inc. All rights reserved. RA4007 User Manuel 1U 4 Fans Unit with Thermostat
More informationETN-24-SUPER-PROG (US Program - Celsius)
Meitavtec Ltd (Contel group) Tel: 972 (3) 962 6462 Fax: 972 (3) 962 6620 www.meitavtec.com support@meitavtec.com ETN24SUPERPROG (US Program Celsius) Owner s Manual Installation and Operating Instructions
More informationELECTRIC DESIGNER RADIATORS
ELECTRIC DESIGNER RADIATORS RF4P RF6P RF8P RF10P RF12P RF14P RF4E RF6E RF8E RF10E RF12E RF14E INSTALLATION INSTRUCTIONS AND USER GUIDE Please read these instructions before installing or using this appliance
More informationLocal Climate. Global Comfort. air curtains radiant heaters fan heaters convectors controls
Local Climate. Global Comfort. air curtains radiant heaters fan heaters convectors controls Welcome to the Frico Mini Catalogue. The Catalogue displays an overview of the Frico range of Commercial Heating
More informationTechnical Information HXV - HRV Ventilation
Technical Information HXV - HRV Ventilation General description Technical data Accessories VENTILATION HXV 5 1 General description 1.01-1.02 2 Technical data 2.01-2.02 3 Accessories 3.01-3.03 HRV 5 4 General
More informationCeiling Concealed Series
FDBM-0916-D Ceiling Concealed Series R22 Ceiling Concealed Product Line Up Indoor Model Outdoor Model Capacity Range TYPE OF REFRIGERANT R22 FDM30/40/50/60CV1M FDB30/40/50/60CV1M R28-30CV1 3.0-6.0 hp R35DV1
More informationYDS Variable Refrigerant Flow System. Digital Scroll Technology 3rd Generation
YDS Variable Refrigerant Flow System Digital Scroll Technology 3rd Generation VRF SYSTEM YDS System Operating range of nominal power (10% - 100 %) Digital Scroll Technology Low noise levels High performance
More informationData sheet Thermostatic sensors type RA 2000
Data sheet Thermostatic sensors type RA 2000 EN 215-1 RA 2990 RA 2992 RA 2920 RA 5060 RA 5074 Application The RA series is a comprehensive programme of radiator thermostats which covers all central and
More informationInstallation and user manual
Installation and user manual Please read carefully and retain for future reference Models EcoHeat: C3, C5, C6, C8, C9, C11, C12 Rev.1_09-07-15 Page 1 Table of Contents 1 IMPORTANT: WARNINGS 1.1 GENERAL
More informationPRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.
PRODUCT DATA COMBI 300 POLAR BY NILAN Ventilation with passive & active heat recovery Domestic Passive heat recovery Active heat recovery Ventilation < 350 m 3 /h Comfort heating Comfort cooling COMBI
More informationTouchpad controller User Manual installation operation
Touchpad controller User Manual installation operation Contents General drawings 2 Fixing control panel to wall 2 1. General installation instructions 3 2. Connecting modular cables 3 3. Connecting additional
More informationETN-24-SUPER-SF Series
Meitav-tec Ltd (Contel group) Tel: +972 (3) 962 6462 Fax: +972 (3) 962 6620 www.meitavtec.com - support@meitavtec.com ETN-24-SUPER-SF Series Owner s Manual Installation and Operating Instructions Please
More informationMini catalogue air curtains radiant heaters fan heaters convectors thermostats. Comfortable and energy efficient indoor climate.
Mini catalogue 2013 air curtains radiant heaters fan heaters convectors thermostats Comfortable and energy efficient indoor climate. Welcome Welcome to the 2013 edition of the Frico Mini Catalogue. We
More informationComfortline L Series The appreciated, flexible Design Air curtain for mounting up to 4 metres
Ambient on request Water heated (WL / WH) Electrically heated (E) Colour customization Lengths,.5, 2, 2.5 and 3 metres ISO 900 Comfortline L Series The appreciated, flexible Design Air curtain for mounting
More informationR410A. AIR CONDITIONER DUCT TYPE / ART Series OPERATING MANUAL. REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A.
AIR CONDITIONER DUCT TYPE / ART Series OPERATING MANUAL KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE R410A REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A. THIS PRODUCT
More informationOriginal instructions AGI4500/6000
Original instructions AGI4500/6000 SE... 18 GB... 21 NO... 24 FR... 27 DE... 31 ES... 35 NL... 39 IT... 43 PL... 47 RU... 51 SE Introduktionssidorna består huvudsakligen av bilder. För översättning av
More information5, SE GÅNGHESTER,
KSUB Control and monitoring unit Valid from week of manufacture 48/2005 Description The KSUB is a control and monitoring unit designed to control various types of fire/smoke dampers and fans in a flexible
More informationGeneral information. Technical data...2 General information...2. Description. Installation
user manual Table of contents Technical data Technical data...2 General information...2 Installation...3 Navigation...3 First run...4 Main screen...6 Main menu...6 Time...7 Date...7 Calendar...7 Language...10
More informationThe latest innovation in cool 7 YEAR 1 YEAR WARRANTY ON PARTS WARRANTY ON COMPRESSORS
The latest innovation in cool 7 YEAR WARRANTY ON COMPRESSORS 1 YEAR WARRANTY ON PARTS Engineered to be both aesthetically pleasing and energy-efficient, Katashi air conditioning units bring the latest
More informationPRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE
Table of Contents PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE # Electric Room Comfort Controller NEW! RDY2000 Room Comfort Controller RDY 129-905 D-3 Electric for Specialized Applications Surface
More informationPART NO. COMBUSTION AIR CAP
ACCESSORIES FOR SPACE-RAY TUBE HEATERS VENT CAP --- Sidewall or Roof Unique design prevents back drafts and assists in drawing off and exhausting the products of combustion regardless of wind direction
More informationPRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h
PRODUCT DATA COMFORT 40 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 40 m /h COMFORT 40 Product description The Comfort 40 is an energy-efficient ventilation
More informationINSTALLATION & USER MANUAL
INSTALLATION & USER MANUAL HC Digital Automatic Humidistat (Y3760) CONTROLS 506808-01 3/2016 Supersedes 6/2011 picture goes here THIS MANUAL MUST BE LEFT WITH THE HOMEOWNER FOR FUTURE REFERENCE NOTICE
More informationTEMPERATURE & PRESSURE CONTROLS
TEMPERATURE & PRESSURE CONTROLS RANCO LUBE OIL PROTECTION CONTROLS These lube oil protection controls guard pressure-lubricated refrigeration compressors against major damage due to loss of oil pressure.
More informationSitron s CF Line of Flow Switch Monitors
Sitron s CF Line of Flow Switch Monitors Models: CF 12AC CF 12DC CF 420 F 420 RCF 420 Introduction Sitron s versatile and intelligent line of Thermal Dispersion Flow Switch Monitors are compact switches,
More informationOPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N
OPERATING MANUAL AIR CONDITIONER DUCT TYPE ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N9374379293-02 CONTENTS SAFETY PRECAUTIONS... 1 NAME OF PARTS... 2 PREPARATORY OPERATION...
More informationForced-air Drying Ovens www.zhichenginstrument.com ISO 9001:2000 ISO13485:2003 High Performance Proven Reliability Advanced Control Description ZXRD/A series forced-air drying ovens manufactured by ZHICHENG
More informationLIGHT COMMERCIAL RANGE Inverter heat pumps suitable for both homes and commercial premises
LIGHT COMMERCIAL RANGE Inverter heat pumps suitable for both homes and commercial premises Toshiba Heat Pumps. We care about better air. Toshiba was the first company to incorporate inverter technology
More informationThermozone RD. Air curtains for revolving doors
Electrical heat 6-36 kw Water heat Thermozone RD Air curtains for revolving doors Thermozone RD is an ideal solution for any environment with revolving doors. The air curtain is mounted on top of the door
More informationHeating Zone Control. How to apply RESOL MX controller
Heating Zone Control How to apply RESOL MX controller Basic Diagram Sensor No Description Relay No. Description S4 Boiler Supply Sensor R5 DHW Loading Pump S5 DHW Tank Temperature Sensor R6 Zone Valve
More informationCONTENTS. Installation Guide. VT7200 Series
VT7200 Series Installation Guide For mercial HVAC Applications November 2015 CONTENTS Installation 2 Location 2 Installation 2 Configurable BI/UI inputs overview 4 Network ready 6 Terminal, Identification
More informationXE99 SERIES FAN-COIL THERMOSTATS 2-PIPE & 4-PIPE FAN-COIL CONTROL FEATURES APPLICATION PRODUCT SPECIFICATION SHEET
XE SERIES FA-COI THERMOSTATS -PIPE & -PIPE FA-COI COTRO APPICATIO The XE range of digital thermostats is designed for control of the fan, valves, compressor or auxiliary electric heater in fan-coil and
More informationOperating Instructions Model : HC HC-N
Operating Instructions Model : HC HC-N This product should be installed by a qualified electrician. Improper installation may result in injury, death or property damage. Contents Table Contents 1 What
More informationADVANCE ECB ELECTRIC COMBINATION BOILER
ISSUE ISSUE 45 0115 0317 INSTALLATION AND USER GUIDE ADVANCE ECB ELECTRIC COMBINATION BOILER ADVANCE APPLIANCES LTD HOUSEHOLDER - PLEASE RETAIN AND ENSURE SERVICE RECORDS ARE KEPT UP TO DATE 1 SCHEMATIC
More informationInverter Ducted Air Conditioners
Inverter Ducted Air Conditioners About Carrier Inverter Ducted Systems Carrier s Inverter Ducted systems allows you to air condition your home without having to install the indoor units on your wall, making
More informationF Operating Manual. ESS0460-H119 PV Module Solar Soaking Chamber
F08-064 Operating Manual ESS0460-H119 PV Module Solar Soaking Chamber 12/19/2008 Thank you for your purchase. We are confident you will be completely satisfied with your new system. If for any reason you
More informationContents. Box contents: JGSTAT2B (Black) Fixing screws (White) Icons used in this manual:
Contents Box contents: Instruction Manual Instruction manual: Box contents Introduction Product compliance System options overview Installation Parameter settings Error codes User guide Installers notes
More informationPCXSPH1732A. Warning. Head office: Umeda Center Bldg., , Nakazaki-Nishi, Kita-ku, Osaka, Japan.
Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether
More informationRA 2000 Series RA 15/6T & TB Conversion Valve
RA 2000 Series RA 15/6T & TB Conversion Valve Applications: RA15/6T Internal bypass allowing for series piping to the radiators/baseboards. This series piping provides continuous flow but the supply water
More informationSemi flush-mount room thermostats
s 1 440 RDD310/EH RDE410/EH Semi flush-mount room thermostats for control of electric floor heating systems and for hydronic zone control systems RDD310/EH RDE410/EH Key features of both types of thermostats:
More informationDaikin Altherma high temperature remote controller guide for schedule timers and operation functions
Daikin Altherma high temperature remote controller guide for schedule timers and operation functions 13 14 15 16 17 1 12 2 11 10 9 3 4 8 7 6 5 1. Space heating on/off 2. Target flow water temperature /
More informationPRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h
PRODUCT DATA COMFORT 00 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 800 m /h COMFORT 00 Product description The Comfort 00 is an energy-efficient ventilation
More informationMODEL REO-1620SE ELECTRIC RETHERMALIZER OPERATING INSTRUCTIONS
MODEL REO-1620SE ELECTRIC RETHERMALIZER OPERATING INSTRUCTIONS 302 Spencer Lane P.O. Box 5369 San Antonio, Texas 78201 (800) 525-8130 (210) 731-5000 FAX: (210) 731-5099 PREFACE This manual was written
More informationROOFTOP PACKAGED AIR CONDITIONERS
ROOFTOP PACKAGED AIR CONDITIONERS Rooftop Packaged Air Conditioners Hitachi has long been a world leader in the design and manufacture of quality air conditioning systems. With models ranging from room
More informationTABLE OF CONTENTS. Principle of operation of CAFM...1. Installation instructions...2. Main ADC Operating screen...3. Set process temp and Setback...
TABLE OF CONTENTS Principle of operation of CAFM....1 Installation instructions......2 Main ADC Operating screen......3 Menu definitions of ADC control Set process temp and Setback.....4 7-Day timer and
More informationElectronic Room Thermostat
telephone the helpline on. ote: a proof of purchase is required Timeguard td) the customer is responsible for all shipping/ Timeguard td. Victory Park, 400 Edgware Road, ondon W2 6D Tel: 020 8452 1112
More informationUser & Installation instruction
LADDOMAT MR 40 User & Installation instruction Scope of delivery Valve package Laddomat 41-100 with: Charge and discharge valve with 2 non-return valves and thermal three-way valve. 2 pumps, LM6A-130.
More informationPERFORMANCE SERIES Single Zone & Multi-Zone Ductless Systems
PERFORMANCE SERIES Single Zone & Multi-Zone Ductless Systems www.emiretroaire.com PN 240012598 REV. [03/20/2019] Single Zone & Multi-Zone Systems Deluxe Heat Series HEAT PUMP ductless mini splits with
More information4 in 1 Digital Thermostat Control
4 in 1 Digital Thermostat Control Models: VS10W and VS10B INSTALLER / USER MANUAL Contents Contents Box contents Introduction Product Compliance System options overview Installation Parameter Settings
More informationteide termo plus+ HEATING SERIES SCOPE THERMOSTATIC VALVES SERVICE CONDITIONS COMPONENTS TECHNICAL SHEET 07/2017 IP20060 PAG. 1/9
HEATING SERIES QUALITY BY TRADITION teide termo plus+ TECHNICAL SHEET 07/2017 IP20060 SCOPE The thermostatic valves and heads from TEIDE TERMO PLUS series can be used in individual or collective heating
More informationINSTALLATION AND MAINTENANCE MANUAL BLITZ FD_
INSTALLATION AND MAINTENANCE MANUAL IST 03 F 017-01 BLITZ FD_ Aluminium electric radiators with heat transfer fluid GB Dear customer, Thank you for choosing our product. Read this manual carefully before
More informationRA15/6T & TB Conversion Valve
Applications: continue on. This provides continuous flow, but inherent to series piping the supply water temperature will decrease as it flows through the system and when it mixes with return water from
More informationTwo-Position Electric Duplex Room Thermostats
TC-XX Series, TC-XX Series, TF- Series Two-Position Electric Duplex Room Thermostats These thermostats provide on-off control of heating/cooling systems. TC-XX Series, TC-XX Series, TF- Series Features:
More informationDUCT AIR HEATER WITH BUILT-IN CONTROLS. Installation & User Instructions. Stock Ref T T T3
DUCT AIR HEATER WITH BUILT-IN CONTROLS Installation & User Instructions Stock Ref. 105 31 100 T1 105 31 125 T1 105 31 150 T1 105 31 200 T1 105 31 250 T1 105 31 315 T1 Stock Ref. 105 31 315 T3 105 31 400
More informationIHC
IHC GB... 6 SE... 9 NO... 11 DE... 13 FR...16 ES... 19 RU... 22 IHC Dimensions 160 0,9 m 77 147 500/676 169 46,5 ø8 17,5 25,5 35 24 60 115 Fig. 1: Wall bracket Positioning Fig. 2: The heaters should heat
More informationDec Wirsbo CoSy Radio. Installation and Operating Instructions
Dec. 2002 Wirsbo CoSy Radio Installation and Operating Instructions Contents 1. Overview... 3 2. Room thermostat... 3 2.1 Thermostat models... 3 2.2 Function... 4 2.3 Positioning... 4 2.4 Setting and limiting
More informationPLXSID1605. Warning HEAD OFFICE :
Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether
More informationMAKING MODERN LIVING POSSIBLE. Danfoss Air Catalogue. Catalogue DANFOSS HEATING
MAKING MODERN LIVING POSSIBLE Danfoss Air Catalogue DANFOSS HEATING Catalogue Danfoss Air units Summary of Danfoss Air The Plug & Play concept ensures a quick installation. Integrated moisture sensors
More information