Comfortline L Series The appreciated, flexible Design Air curtain for mounting up to 4 metres
|
|
- Barnard Hawkins
- 5 years ago
- Views:
Transcription
1 Ambient on request Water heated (WL / WH) Electrically heated (E) Colour customization Lengths,.5, 2, 2.5 and 3 metres ISO 900 Comfortline L Series The appreciated, flexible Design Air curtain for mounting up to 4 metres Application Comfortline L Series air curtains are intended for exclusive shop entrances with high demands on design. Available for both horizontal and vertical mounting. Adaption of colour and material is possible for blending into the environment. Comfort The L Series is available with a number of different fan decks, which together with both water and electrical heating alternatives makes creating a comfortable climate in any entrance easy. The outlet wing is adjustable and developed to direct part of the air stream to the sides of the door, thus decreasing the cold air leakage. Operation and economy The air inlet grille acts as a filter making the air curtain easy to clean without opening the unit. With nut rails on the top of the unit the mounting is made flexible and it also enables fixing multiple units next to each other, visibly as one unit. Product specifications Available for horizontal and vertical mounting. BMS-control option included. Other controls like IR-Remote and manual-automatic are available as accessory. Flexible connection possibilities. Flexible suspension points through hanging rail and chanelled profile system. Covering for mounting systems, water- and electrical connections available as an accessory. Extensive colour and material customization possibilities. Intermediate length adaption up to 3 meter length. Air velocity profile*¹ Design Comfortline L Series is an exceptionally beautifully designed air curtain which has received appreciation on the market for a long time. It can be freely adapted to the surroundings by a choice of materials, intermediate lenghts and even multiple colours per unit. For neat installations special covers for suspensions, pipes and cables are available. *¹) Mean value across the whole outlet area. Design and specifications are subject to change without notice.
2 Technical specifications Comfortline L Series W with water heat 2 Type Airflow*¹ Sound pressure*² Sound power Voltage Amperage*³ Power*³ Connections Dimension* 4 Length (L) Weight [m³/h] [db(a)] [db(a)] [V] [A] [mm] [mm] [kg] S000WL / S000WH /47 44/63 230V~,7 0,370 /2" S500WL / S500WH /49 46/65 230V~ 2,5 0,555 /2" S2000WL / S2000WH /50 47/66 230V~ 3,3 0,740 3/4" (WL) /2" (WH) S2500WL / S2500WH /5 48/67 230V~ 4,2 0,925 3/4" S3000WL / S3000WH /52 49/68 230V~ 5,0,0 3/4" M000WL / M000WH /50 48/66 230V~ 2,5 0,555 3/4" M500WL / M500WH /50 48/66 230V~ 2,5 0,555 3/4" M2000WL / M2000WH /52 50/68 230V~ 4,2 0,925 3/4" M2500WL / M2500WH /53 5/69 230V~ 5,0,0 3/4" M3000WL / M3000WH /53 5/69 230V~ 5,8,295 " (WL) /4" (WH) G000WL / G000WH /53 50/69 230V~ 3,6 0,82 3/4" G500WL / G500WH /54 5/70 230V~ 4,8,095 3/4" G2000WL / G2000WH /56 53/72 230V~ 7,,642 3/4" G2500WL / G2500WH /56 53/72 230V~ 8,3,96 3/4" G3000WL / G3000WH /57 54/73 230V~ 9,5 2,90 " (WL) 3/4" (WH) B500WL / B500WH /55 50/7 230V~ 4,2 0,980 " (WL) /4" (WH) B2000WL / B2000WH /57 52/73 230V~ 6,3,470 /4" (WL) " (WH) B2500WL / B2500WH /58 53/74 230V~ 8,4,960 /4" B3000WL / B3000WH /59 54/75 230V~ 8,4 2,450 /2" (WL) /4" (WH) BB000WL / BB000WH /55 50/7 230V~ 4,2 0,980 " BB500WL / BB500WH /57 52/73 230V~ 6,3,470 " (WL) /4" (WH) BB2000WL / BB2000WH /58 53/74 230V~ 8,4,960 /4" (WL) " (WH) BB2500WL / BB2500WH /59 54/75 230V~ 0,5 2,450 /4" BB3000WL / BB3000WH /60 55/76 230V~ 2,6 2,940 /2" (WL) /4" (WH) *¹) Max airflow, out of 5 steps. *²) At lowest/highest airflow. Conditions: Distance to the unit 5 metres. Directional factor:2. Equivalent absorption area: 200 m². *³) Rated capacity data. * 4 ) Connections are inside thread. DN5 = /2, DN20 = 3/4 DN25=, DN32= /4, DN40= /2. Protection class Comfortline L-Series water heated: (IP44) splash-proof design. CE compliant. 2
3 Technical specifications Comfortline L Series E with electrical heat 3 Type steps Airflow*¹ [m³/h] t*² Sound pressure*³ [db(a)] Sound power [db(a)] Voltage* 4 Amperage (control) Power* 4 Voltage Amperage (heat) Length (L) [mm] Weight [kg] S000E09 3/6/ /47 44/63 230V~/,7A 0, V3~/3A S500E2 4/8/ /49 46/65 230V~/2,5A 0, V3~/7,5A S2000E8 6/2/ /50 47/66 230V~/3,3A 0, V3~/26A S2500E8 6/2/ /5 48/67 230V~/4,2A 0, V3~/26A S3000E24 8/6/ /52 49/68 230V~/5,0A,0 400V3~/35A M000E09 3/6/ /50 48/66 230V~/2,5A 0, V3~/3A M500E2 4/8/ /50 48/66 230V~/2,5A 0, V3~/7,5A M2000E8 6/2/ /52 50/68 230V~/4,2A 0, V3~/26A M2500E8 6/2/ /53 5/69 230V~/5,0A,0 400V3~/26A M3000E24 8/6/ /53 5/69 230V~/5,8A, V3~/35A G000E5 5/0/ /53 50/69 230V~/3,6A 0,82 400V3~/22A G500E23 7,5/5/22, /54 5/70 230V~/4,8A, V3~/32,5A G2000E30 0/20/ /56 53/72 230V~/7,A, V3~/43,5A G2500E36 2/24/ /56 53/72 230V~/8,3A,96 400V3~/52A G3000E45 5/30/ /57 54/73 230V~/9,5A 2,90 400V3~/65A *¹) Max airflow, out of 3 steps. *²) t = temperature rise of passing air at maximum heat output and highest airflow. *³) At lowest/highest airflow. Conditions: Distance to the unit 5 metres. Directional factor:2. Equivalent absorption area: 200 m². * 4 ) Rated capacity data. Protection class Comfortline L Series electrically heated: (IP2) drip-proof design. CE compliant. Performance type B and BB available on request. 3
4 Dimensions D H S M/G B/BB Chanelled profile L = Length / Height 4
5 Positioning, mounting and installation Positioning Comfortline L-series is available for horizontal as well as vertical mounting. Horizontally, the air curtain is positioned hanging visibly above the door. Vertically, it is standing next to the door on either the left or the right side. In both cases the outlet of the air curtain should be positioned as close to the door as possible. Mounting Horizontal mounting is carried out using threaded rods for ceiling support (M8 for S/M/G and M0 for B/BB). Wall brackets for horizontal mounting are available in a variety of designs as an accessory. Please contact Gelu- Frico for more information. A vertical unit is mounted standing on the accompanying floor bracket that is bolted to the floor and must be secured to a wall or to the ceiling to prevent it from falling over. Connection Comfortline L-series with water heating The 230V~ supply is connected to the terminals inside the unit. The cable is taken into the unit via the premounted cable glands. The supply should be carried out with a service switch and with fuse according to technical data. The control panel is delivered with 0 m RJ45 cable. For more connection possibilities please see wiring diagrams. Heating coil is equipped with inner thread connections. Connection Comfortline L-series with electrical heating The air curtain needs wiring for 230V~ supply and control and 400V3~ supply. Each supply should be carried out with a service switch and with fuse according to technical data. For more connection possibilities please see wiring diagrams. Ordering Ordering key Model name - Performance - Length - Heat medium - Unit shape - Electrical - Water - Customization connections connections position position Model name Performance Comfortline L-series S, M, G, B or BB type performance Length 000, 500, 2000, 2500 or 3000 Heat medium Unit shape Electrical connections position Water connections position Customization WL (low temperature water), WH (high temperature water) or E (electrical). Ambient on request. H (Horizontal), VL (Vertical Left), VR (Vertical Right)., 2, 3 or 4. See below., 2, 3 or 4. See below. Specify two-pack or powder coating, RAL-code or NCS-code, or stainless steel quality. Connections position Ordering example To order a Comfortline L-series unit, with G performance, in 2 m length, with electrical heating, hanging above the door and with connections from the left side (as seen from the inside), the order line should look like this: Comfortline L-series - G E30 - H
6 6 Comfortline L Series
7 charts water WH heating coils Type Airflow [m³/h] Recommended operation*¹ Heating capacity*² Heating capacity*² Incoming water: 30 C Incoming air: 5 C Incoming air: 20 C In / out air temp.: 8/33 C In / out water temp.: 30/70 C In / out water temp.: 30/70 C Return water S000WH 200 6, 35 0,02,5 44 0,05 0,7 47 0,04 S500WH 800 9, 43 0,03 6,4 42 0,07 5,3 45 0,06 S2000WH , 38 0,03 2,5 42 0,09 20,0 45 0,08 S2500WH ,2 36 0,04 28,0 43 0,2 26,0 46 0, S3000WH ,2 45 0,05 54,2 60 0,23 50,5 62 0,2 M000WH 800 9, 32 0,02 8,5 46 0,08 7,3 49 0,07 M500WH ,6 46 0,04 28,8 49 0,2 26,6 52 0, M2000WH ,2 33 0,05 36,5 45 0,5 34,0 48 0,4 M2500WH ,2 36 0,06 53,3 5 0,22 49,6 54 0,2 M3000WH ,2 39 0,07 66,9 55 0,28 62,3 57 0,26 G000WH ,6 39 0,04 24,7 42 0,0 23,0 45 0,09 G500WH ,2 35 0,05 36,9 45 0,5 34,3 48 0,4 G2000WH ,3 37 0,07 57,5 47 0,24 53,4 49 0,22 G2500WH ,8 33 0,08 67,3 47 0,28 62,7 50 0,26 G3000WH ,4 35 0,09 83,5 49 0,34 77,7 52 0,32 B500WH ,2 35 0,06 47,7 43 0,20 44,5 47 0,8 B2000WH ,9 33 0,0 79,4 46 0,33 74,0 49 0,3 B2500WH ,5 34 0,3 03,9 46 0,43 96,8 49 0,40 B3000WH , 33 0,6 29,8 46 0,54 20,9 49 0,50 BB000WH ,2 36 0,07 5,3 46 0,2 47,6 48 0,20 BB500WH ,9 43 0, 59,9 39 0,25 55,8 42 0,23 BB2000WH ,5 37 0,3 98,2 44 0,4 9,5 47 0,38 BB2500WH , 37 0,7 7,7 43 0,49 09,5 46 0,45 BB3000WH ,7 40 0,2 44,2 44 0,60 33,8 47 0,55 *¹) To save energy and create good comfort in openings not exposed to unusual loads. *²) For heating capacity at others speeds than full the conversion table to the right can be used. T is the temperature difference between incoming and outgoing air. Fan position Airflow T Max (5/5) 00% Mid (3/5) 75% 0,842,33 0,842 Min (/5) 50% 0,65,35 0,65 Heating coil max water temperature 20 C and max pressure 6 bar. For inlet temperature 30 C the return temperature must be kept below 70 C. Mean water temperature must not exceed 00 C. 7
8 charts water WH heating coils Type Airflow [m³/h] Recommended operation*¹ Heating capacity*² Heating capacity*² Incoming water: 0 C Incoming air: 5 C Incoming air: 20 C In / out air temp.: 8/33 C In / out water temp.: 0/80 C In / out water temp.: 0/80 C Return water S000WH 200 6, 40 0,02,8 44 0,0,0 47 0,09 S500WH 800 9, 43 0,03 7,0 43 0,4 5,9 46 0,3 S2000WH , 43 0,04 22,0 42 0,8 20,6 46 0,7 S2500WH ,2 40 0,05 28,4 43 0,23 26,5 46 0,22 S3000WH ,2 43 0,07 55,2 6 0,46 5,6 63 0,43 M000WH 800 9, 37 0,03 8,9 46 0,6 7,6 49 0,4 M500WH ,6 44 0,05 29,8 50 0,25 27,8 53 0,23 M2000WH ,2 36 0,06 36,9 45 0,30 34,5 49 0,28 M2500WH ,2 36 0,07 54,6 52 0,45 50,8 54 0,42 M3000WH ,2 38 0,09 68,5 56 0,56 63,9 58 0,53 G000WH ,6 43 0,05 25,7 43 0,2 24,0 46 0,20 G500WH ,2 38 0,06 37,9 46 0,3 35,4 49 0,29 G2000WH ,3 38 0,09 60,0 48 0,49 56,0 5 0,46 G2500WH ,8 36 0, 69,2 48 0,57 64,7 5 0,53 G3000WH ,4 36 0,2 86,0 5 0,7 80,3 53 0,66 B500WH ,2 35 0,06 48,4 44 0,40 45,3 47 0,37 B2000WH ,9 33 0,0 8,6 47 0,67 76,0 50 0,63 B2500WH ,5 34 0,3 06,6 47 0,88 99,6 50 0,82 B3000WH , 33 0,6 32,8 47,09 24, 50,02 BB000WH ,2 36 0,07 53,8 47 0,44 50, 50 0,4 BB500WH ,9 43 0, 6,0 39 0,50 57,0 43 0,47 BB2000WH ,5 37 0,3 00,4 45 0,83 93,8 48 0,78 BB2500WH , 37 0,7 2,5 44,00 3,5 47 0,94 BB3000WH ,7 40 0,2 47,7 44,22 38, 47,4 *¹) To save energy and create good comfort in openings not exposed to unusual loads. *²) For heating capacity at others speeds than full the conversion table to the right can be used. T is the temperature difference between incoming and outgoing air. Fan position Airflow T Max (5/5) 00% Mid (3/5) 75% 0,842,33 0,842 Min (/5) 50% 0,65,35 0,65 Heating coil max water temperature 20 C and max pressure 6 bar. For inlet temperature 30 C the return temperature must be kept below 70 C. Mean water temperature must not exceed 00 C. 8
9 charts water WH heating coils Type Airflow [m³/h] Recommended operation*¹ Heating capacity*² Heating capacity*² Incoming water: 90 C Incoming air: 5 C Incoming air: 20 C In / out air temp.: 8/33 C In / out water temp.: 90/70 C In / out water temp.: 90/70 C Return water S000WH 200 6, 45 0,03 9,7 39 0,2 8,9 42 0, S500WH 800 9, 48 0,05 4,0 38 0,7 2,9 4 0,6 S2000WH , 48 0,07 8, 37 0,22 6,7 4 0,2 S2500WH ,2 46 0,08 23,2 38 0,29 2,4 4 0,26 S3000WH ,2 40 0,09 45, 52 0,55 4,7 54 0,5 M000WH 800 9, 4 0,04 5,5 4 0,9 4,3 44 0,8 M500WH ,6 43 0,06 24,5 44 0,30 22,5 47 0,28 M2000WH ,2 42 0,09 30,3 40 0,37 27,8 43 0,34 M2500WH ,2 36 0,0 44,6 45 0,55 4, 48 0,5 M3000WH ,2 37 0,2 56,3 48 0,69 5,8 5 0,64 G000WH ,6 48 0,08 2, 38 0,26 9,4 4 0,24 G500WH ,2 43 0,09 3,2 4 0,38 28,7 44 0,35 G2000WH ,3 42 0,4 49,2 42 0,6 45,2 45 0,56 G2500WH ,8 4 0,6 56,7 42 0,70 52,2 45 0,64 G3000WH ,4 38 0,7 70,8 44 0,87 64,9 47 0,80 B500WH ,2 45 0,4 39,7 39 0,49 36,5 42 0,45 B2000WH ,9 4 0,9 66,9 42 0,82 6,5 44 0,76 B2500WH ,5 42 0,26 87,7 4,08 80,7 44 0,99 B3000WH , 42 0,32 09,2 4,34 00,5 44,23 BB000WH ,2 44 0,3 44,4 4 0,54 40,8 44 0,50 BB500WH ,9 54 0,26 50,0 35 0,6 45,8 38 0,56 BB2000WH ,5 46 0,28 82,3 39,0 75,7 43 0,93 BB2500WH , 46 0,35 99,7 39,23 9,7 42,3 BB3000WH ,7 50 0,46 2, 39,49,4 42,37 *¹) To save energy and create good comfort in openings not exposed to unusual loads. *²) For heating capacity at others speeds than full the conversion table to the right can be used. T is the temperature difference between incoming and outgoing air. Fan position Airflow T Max (5/5) 00% Mid (3/5) 75% 0,842,33 0,842 Min (/5) 50% 0,65,35 0,65 Heating coil max water temperature 20 C and max pressure 6 bar. For inlet temperature 30 C the return temperature must be kept below 70 C. Mean water temperature must not exceed 00 C. 9
10 charts water WH heating coils Type Airflow [m³/h] Recommended operation*¹ Heating capacity*² Heating capacity*² Incoming water: 80 C Incoming air: 5 C Incoming air: 20 C In / out air temp.: 8/33 C In / out water temp.: 80/60 C In / out water temp.: 80/60 C Return water S000WH 200 6, 48 0,05 8, 35 0,0 7,3 38 0,09 S500WH 800 9, 5 0,08,6 34 0,4 0,4 37 0,3 S2000WH , 5 0,0 5,0 34 0,8 3,6 37 0,7 S2500WH ,2 49 0,2 9,4 34 0,24 7,5 37 0,2 S3000WH ,2 39 0, 37,6 46 0,46 33,8 48 0,4 M000WH 800 9, 45 0,06 2,9 36 0,6,6 39 0,4 M500WH ,6 42 0,08 20,3 39 0,25 8,3 42 0,22 M2000WH ,2 45 0,3 25, 36 0,3 22,8 39 0,28 M2500WH ,2 39 0,3 37,0 40 0,45 33,4 43 0,4 M3000WH ,2 37 0,4 46,6 43 0,57 42, 45 0,5 G000WH ,6 50 0, 7,5 34 0,2 5,7 37 0,9 G500WH ,2 45 0,3 25,8 36 0,32 23,3 39 0,29 G2000WH ,3 44 0,9 40,8 37 0,50 36,6 40 0,45 G2500WH ,8 43 0,2 47,2 37 0,58 42,4 40 0,52 G3000WH ,4 4 0,23 58,5 39 0,7 52,8 42 0,64 B500WH ,2 48 0,9 33,0 35 0,40 29,9 38 0,37 B2000WH ,9 44 0,25 5,6 37 0,68 50,0 40 0,6 B2500WH ,5 45 0,35 72,6 37 0,89 65,6 40 0,80 B3000WH , 44 0,43 90,5 37, 8,7 40,00 BB000WH ,2 46 0,8 36,5 37 0,45 32,9 40 0,40 BB500WH ,9 58 0,43 4,6 32 0,5 37,6 35 0,46 BB2000WH ,5 49 0,40 68,5 35 0,84 6,9 38 0,76 BB2500WH , 49 0,49 82,8 35,0 74,7 38 0,9 BB3000WH ,7 53 0,69 00,7 35,23 9,0 38, *¹) To save energy and create good comfort in openings not exposed to unusual loads. *²) For heating capacity at others speeds than full the conversion table to the right can be used. T is the temperature difference between incoming and outgoing air. Fan position Airflow T Max (5/5) 00% Mid (3/5) 75% 0,842,33 0,842 Min (/5) 50% 0,65,35 0,65 Heating coil max water temperature 20 C and max pressure 6 bar. For inlet temperature 30 C the return temperature must be kept below 70 C. Mean water temperature must not exceed 00 C. 0
11 charts water WL heating coils Type Airflow [m³/h] Recommended operation*¹ Heating capacity*² Heating capacity*² Incoming water: 80 C Incoming air: 5 C Incoming air: 20 C In / out air temp.: 8/33 C In / out water temp.: 80/60 C In / out water temp.: 80/60 C Return water S000WL 200 6, 29 0,03 3,0 47 0,6,7 49 0,4 S500WL 800 9, 30 0,04 9,6 47 0,24 7,7 49 0,22 S2000WL , 30 0,06 24,2 45 0,29 2,9 47 0,27 S2500WL ,2 26 0,07 35, 50 0,43 3,8 52 0,39 S3000WL ,2 29 0,09 36,8 45 0,45 33,2 47 0,4 M000WL 800 9, 32 0,05 8,0 45 0,22 6,3 47 0,20 M500WL ,6 28 0,06 27, 47 0,33 24,5 49 0,30 M2000WL ,2 29 0,09 4,0 49 0,50 37,0 5 0,45 M2500WL ,2 35 0,3 46,7 47 0,57 42,3 49 0,52 M3000WL ,2 39 0,5 48,9 44 0,60 44,3 46 0,54 G000WL ,6 37 0,08 23,3 4 0,28 2,0 43 0,26 G500WL ,2 32 0,09 34,6 44 0,42 3,4 46 0,38 G2000WL ,3 32 0,4 54,0 45 0,66 48,9 47 0,60 G2500WL ,8 35 0,7 59,0 43 0,72 53,3 45 0,65 G3000WL ,4 29 0,8 7, 44 0,87 64,5 47 0,79 B500WL ,2 36 0,4 46,0 42 0,56 4,5 45 0,5 B2000WL ,9 3 0,9 74,9 45 0,92 67,9 47 0,83 B2500WL ,5 32 0,25 96,5 44,8 87,5 46,07 B3000WL , 33 0,33 8,7 43,45 07, 46,3 BB000WL ,2 34 0,3 48,4 44 0,59 43,7 46 0,53 BB500WL ,9 42 0,24 59,0 38 0,72 53,2 4 0,65 BB2000WL ,5 35 0, ,0 8,5 44,00 BB2500WL , 35 0,34 0,9 4,36 00,5 44,23 BB3000WL ,7 35 0,4 32,9 4,63 20,3 44,47 *¹) To save energy and create good comfort in openings not exposed to unusual loads. *²) For heating capacity at others speeds than full the conversion table to the right can be used. T is the temperature difference between incoming and outgoing air. Fan position Airflow T Max (5/5) 00% Mid (3/5) 75% 0,842,33 0,842 Min (/5) 50% 0,65,35 0,65 Heating coil max water temperature 20 C and max pressure 6 bar. For inlet temperature 30 C the return temperature must be kept below 70 C. Mean water temperature must not exceed 00 C.
12 charts water WL heating coils Type Airflow [m³/h] Recommended operation*¹ Heating capacity*² Heating capacity*² Incoming water: 70 C Incoming air: 5 C Incoming air: 20 C In / out air temp.: 8/33 C In / out water temp.: 70/40 C In / out water temp.: 70/40 C Return water S000WL 200 6, 3 0,04 8,7 36 0,07 7,4 38 0,06 S500WL 800 9, 3 0,06 3,0 37 0,,0 38 0,09 S2000WL , 33 0,08 6,2 35 0,3 3,8 37 0, S2500WL ,2 28 0,09 23,9 39 0,9 20,4 40 0,6 S3000WL ,2 32 0, 25,0 36 0,20 2,3 38 0,7 M000WL 800 9, 35 0,06,8 34 0,09 0,0 37 0,08 M500WL ,6 3 0,08 8,3 37 0,5 5,6 39 0,3 M2000WL ,2 30 0, 27,3 38 0,22 23,2 39 0,9 M2500WL ,2 35 0,5 30,3 36 0,24 25,7 37 0,2 M3000WL ,2 38 0,9 32,7 34 0,26 27,9 37 0,23 G000WL ,6 40 0, 2,0 43 0,26 2,7 34 0,0 G500WL ,2 35 0,3 23, 34 0,9 9,7 36 0,6 G2000WL ,3 34 0,9 35,5 35 0,29 30,2 37 0,24 G2500WL ,8 37 0,24 38,0 33 0,3 32,2 35 0,26 G3000WL ,4 32 0,23 47,4 35 0,38 40,4 37 0,33 B500WL ,2 39 0,9 29,3 32 0,24 24,6 35 0,20 B2000WL ,9 34 0,25 49,7 35 0,40 42,4 37 0,34 B2500WL ,5 35 0,35 64,3 34 0,52 54,9 36 0,44 B3000WL , 36 0,45 78,3 34 0,63 66,4 36 0,54 BB000WL ,2 37 0,8 30,9 33 0,25 26, 36 0,2 BB500WL ,9 36 0,27 37,2 30 0,30 3,2 32 0,25 BB2000WL ,5 38 0,38 59,4 33 0,48 50,5 35 0,4 BB2500WL , 38 0,48 73,7 33 0,60 62,8 35 0,5 BB3000WL ,7 39 0,59 87,4 32 0,7 74,3 35 0,60 *¹) To save energy and create good comfort in openings not exposed to unusual loads. *²) For heating capacity at others speeds than full the conversion table to the right can be used. T is the temperature difference between incoming and outgoing air. Fan position Airflow T Max (5/5) 00% Mid (3/5) 75% 0,842,33 0,842 Min (/5) 50% 0,65,35 0,65 Heating coil max water temperature 20 C and max pressure 6 bar. For inlet temperature 30 C the return temperature must be kept below 70 C. Mean water temperature must not exceed 00 C. 2
13 charts water WL heating coils Type Airflow [m³/h] Recommended operation*¹ Heating capacity*² Heating capacity*² Incoming water: 60 C Incoming air: 5 C Incoming air: 20 C In / out air temp.: 8/33 C In / out water temp.: 60/40 C In / out water temp.: 60/40 C Return water S000WL 200 6, 35 0,06 7,9 35 0,09 6,6 36 0,08 S500WL 800 9, 35 0,09,8 35 0,4 9,9 36 0,2 S2000WL , 37 0,3 4,7 33 0,8 2,4 35 0,5 S2500WL ,2 3 0,3 2,6 36 0,26 8,2 38 0,22 S3000WL ,2 36 0,8 22,5 34 0,27 9,0 36 0,23 M000WL 800 9, 38 0,0 0,8 33 0,3 9,0 35 0, M500WL ,6 34 0,2 6,6 35 0,20 3,9 37 0,7 M2000WL ,2 33 0,6 24,8 36 0,30 20,9 37 0,25 M2500WL ,2 36 0,23 27,8 34 0,34 23,3 36 0,28 M3000WL ,2 37 0,26 29,7 33 0,36 25,0 35 0,30 G000WL ,6 38 0,5 3,9 30 0,7,6 33 0,4 G500WL ,2 39 0,2 2,0 32 0,26 7,6 35 0,2 G2000WL ,3 38 0,29 32,4 33 0,39 27, 35 0,33 G2500WL ,8 40 0,39 35,0 32 0,43 29,3 34 0,36 G3000WL ,7 33 0,29 43, 33 0,52 36,3 35 0,44 B500WL ,2 4 0,33 27, 3 0,33 22,5 33 0,27 B2000WL ,9 37 0,40 45,3 33 0,55 38, 35 0,46 B2500WL ,5 38 0,56 58,5 32 0,7 49, 35 0,59 B3000WL , 39 0,74 7,5 32 0,87 59,8 34 0,73 BB000WL ,2 40 0,30 28,5 29 0,34 23,8 34 0,29 BB500WL ,9 48 0,74 34,5 3 0,42 28,6 3 0,35 BB2000WL ,5 4 0,66 54,3 3 0,66 45,6 34 0,55 BB2500WL , 40 0,75 67, 3 0,8 56,5 33 0,68 BB3000WL ,7 42,03 79,9 3 0,97 67, 33 0,8 *¹) To save energy and create good comfort in openings not exposed to unusual loads. *²) For heating capacity at others speeds than full the conversion table to the right can be used. T is the temperature difference between incoming and outgoing air. Fan position Airflow T Max (5/5) 00% Mid (3/5) 75% 0,842,33 0,842 Min (/5) 50% 0,65,35 0,65 Heating coil max water temperature 20 C and max pressure 6 bar. For inlet temperature 30 C the return temperature must be kept below 70 C. Mean water temperature must not exceed 00 C. 3
14 charts water WL heating coils Type Airflow [m³/h] Recommended operation*¹ Heating capacity*² Heating capacity*² Incoming water: 55 C Incoming air: 5 C Incoming air: 20 C In / out air temp.: 8/33 C In / out water temp.: 55/35 C In / out water temp.: 55/35 C Return water S000WL 200 6, 37 0,08 6,6 3 0,08 5,3 33 0,06 S500WL 800 9, 36 0,2 9,9 3 0,2 8,0 33 0,0 S2000WL , 39 0,8 2,3 30 0,5 9,9 32 0,2 S2500WL ,2 33 0,7 8, 33 0,22 4,6 35 0,8 S3000WL ,4 34 0,9 9,0 3 0,23 5,4 33 0,9 M000WL 800 9, 40 0,4 8,9 30 0, 7,2 32 0,09 M500WL ,6 36 0,6 3,8 3 0,7,2 33 0,4 M2000WL ,2 35 0,22 20,8 32 0,25 6,7 34 0,20 M2500WL ,2 38 0,3 23, 3 0,28 8,4 32 0,22 M3000WL ,4 39 0,36 24,8 30 0,30 20,0 32 0,24 G000WL ,2 44 0,29,5 28 0,4 9,2 30 0, G500WL ,4 37 0,22 7,5 30 0,2 4,2 32 0,7 G2000WL ,3 40 0,43 26,9 30 0,33 2,6 32 0,26 G2500WL ,8 42 0,60 29,0 29 0,35 23, 3 0,28 G3000WL , 3 0,29 35,9 30 0,43 29,0 32 0,35 B500WL ,2 43 0,5 22,3 28 0,27 7,7 3 0,2 B2000WL ,9 39 0,59 37,9 30 0,46 30,4 32 0,37 B2500WL ,8 39 0,75 48,8 30 0,59 39,4 32 0,48 B3000WL , 42,3 59,4 29 0,72 47,9 3 0,58 BB000WL ,2 4 0,44 23,6 29 0,29 8,7 3 0,23 BB500WL ,9 44 0,83 28,3 26 0,34 22,4 29 0,27 BB2000WL ,5 4 0,80 45,3 28 0,55 36,3 3 0,44 BB2500WL ,6 37 0,7 56, 28 0,68 45, 3 0,54 BB3000WL ,6 39 0,98 66,6 28 0,8 53,4 3 0,64 *¹) To save energy and create good comfort in openings not exposed to unusual loads. *²) For heating capacity at others speeds than full the conversion table to the right can be used. T is the temperature difference between incoming and outgoing air. Fan position Airflow T Max (5/5) 00% Mid (3/5) 75% 0,842,33 0,842 Min (/5) 50% 0,65,35 0,65 Heating coil max water temperature 20 C and max pressure 6 bar. For inlet temperature 30 C the return temperature must be kept below 70 C. Mean water temperature must not exceed 00 C. 4
15 Pressure drop water Water pressure drop over Comfortline L-series WH water coils type S [m³/h] 0,,0 0 Pressure drop [kpa] 70 S2500WH 0,7 Pressure drop [bar] 0 0, S000WH S2000WH S500WH S3000WH 0,0 0,,0 Pressure drop water 0,0 Water pressure drop over Comfortline L-series WH water coils type M [m³/h] 0,,0 0 Pressure drop [kpa] 70 M2500WH 0,7 Pressure drop [bar] 0 0, M000WH M2000WH M500WH M3000WH 0,0 0,0 0,,0 5
16 Pressure drop water Water pressure drop over Comfortline L-series WH water coils type G [m³/h] 0,,0 0 Pressure drop [kpa] 70 G2500WH 0,7 Pressure drop [bar] 0 0, G000WH G500WH G2000WH G3000WH 0,0 0,,0 Pressure drop water 0,0 Water pressure drop over Comfortline L-series WH water coils type B [m³/h] 0,, ,7 Pressure drop [kpa] Pressure drop [bar] 0 0, 0,0 0,0 0,,0 6
17 Pressure drop water Water pressure drop over Comfortline L-series WH water coils type BB [m³/h] 0,, ,7 Pressure drop [kpa] Pressure drop [bar] 0 0, 0,0 0,,0 0,0 Water pressure drop over Comfortline L-series WL water coils type S [m³/h] 0,, ,7 Pressure drop [kpa] Pressure drop [bar] 0 0, S000WL S3000WL S2000WL S500WL S2500WL 0,0 0,,0 0,0 7
18 Pressure drop water Water pressure drop over Comfortline L-series WL water coils type M [m³/h] 70 0,,0 0 0,7 0 0, M500WL M000WL M3000WL M2000WL M2500WL 0,0 0,0 0,,0 Water pressure drop over Comfortline L-series WL water coils type G 0,, ,7 Pressure drop [kpa] Pressure drop [bar] Pressure drop [kpa] Pressure drop [bar] [m³/h] 0 0, G500WL G000WL G2000WL G3000WL G2500WL 0,0 0,0 0,,0 8
19 Pressure drop water Water pressure drop over Comfortline L-series WL water coils type B [m³/h] 0,, ,7 0 0, 0,0 0,0 0,,0 70 0,,0 0 0,7 Pressure drop [kpa] Pressure drop [bar] Pressure drop [kpa] Pressure drop [bar] Pressure drop water Water pressure drop over Comfortline L-series WL water coils type BB [m³/h] 0 0, 0,0 0,0 0,,0 9
20 Pressure drop water Water presssure drop over regulations and valves [m³/h] 0,, ,7 Pressure drop [kpa] 0 GTVV5 GTVV20 GTVV25 GTVV32 GTRV20 GTRV25 GTRV40 0, Pressure drop [bar] 0,0 0,,0 0,0 [m³/h] 0,, ,7 Pressure drop [kpa] Pressure drop [bar] 0 0, 0,0 0,,0 The pressure drop is calculated for an average temperature of 70 C (PWW 80/60). For other water temperatures, the pressure drop is multiplied by the factor K. Average temp. water C K,0,06,03,00 0,97 0,93 0,0 20
21 Complete control kits Water 2 Standard control With the standard control panel D705IR the fan speed is selected in five steps. With the summer/winter switch the heating is turned on/off. The control panel is configured for dual functionality which is switched with an external contact, i.e. a door contact or a room thermostat, that may be connected to the control panel. With a DIP-switch inside the control panel it is decided whether the external contact switches the air curtain on/off (Position ON) or if it switches between high and low speed (Position OFF). High speed is choosen freely among the five fan speeds available. The high speed is set on the controller when the contact is open. To save the motors of the air curtain an over-run time between 5 and 75 seconds can be set on the controller. Electric 3 Standard control The standard control panel D700e controls the fan speed and the heating in three steps respectively. The heating steps are coordinated with the selected fan speed to prevent risk of overheating. A room thermostat can be connected to the controller to automatically switch heating and fans on and off. The controller also has an over-run function which may start the fan after switch-off to remove excess heat. When the unit has cooled down the fans are shut off. The memory function (DIP-switch inside= ON) remembers which fan speed and heating step are used so that they are turned back on after a power failure. Up to 4 units can be controlled simultaneously. Up to 2 units can be controlled simultaneously. BMS control The water heated air curtain is prepared for BMScontrol via the 0-0V terminals on the internal PC-board. The valve must then be controlled via an external room thermostat. For more information regarding control alternatives please contact Gelu-Frico. 2
22 Wiring diagrams Comfortline L-series WL/WH Control alternatives water heating J J2 J3 J4 J5 J7 SW External contact 230 V~ connection. RJ45 cable for connection to controller. For connection to slave unit. Up to 2 units can be connected to one control unit. For 0-0 V control use J5 on all units. Remove bridge for start/stop through BMS system. Open contact = off. 0-0 V control via BMS system. See SW. Magnetic valve connection. Activated by summer/winter switch on control unit. For 0-0 V BMS control put switch in position ON. For normal function set switch in position OFF. Connect external contact to terminals in controller for on/off function. 0-0 V Input signal (for BMS control) 5 Fan speed External contact Open contact = air curtain on / high speed Closed contact = air curtain off / low speed D705IR controller 0,0,0 2,5 4,0 5,5 7, 0 8,5 0,0 Voltage Wiring diagrams Comfortline L-series E Control alternatives electric heating * For connection to slave unit. Up to 4 units can be connected to one control unit. Bridge C and 5 in all units. C4-C5 J5-J6 Remove bridge to connect external contact. It switches both heating and fans. Closed contact=on. Not used. For more information regarding control alternatives please contact Gelu-Frico. 22
23 Accessories Controllers D705IR IR0 D700E D75M Standard controller for water heated and ambient air curtains (included in delivery). Infrared remote controller for use with D705IR. Standard controller for electrically heated air curtains (included in delivery). Programmable manual/automatic controller for water heated units. Enables control with room thermostat and door contact. Door contacts GLS Mechanical position limit switch. MDC Magnetic door contact with 3 alternating contacts and time delay function. Thermostats TBK0 Mechanical bimetal thermostat with gas-filled membrane. Alternating contact. External dial. T0 Electronic thermostat. Internal dial. Max 0 A. TK0 Electronic thermostat. External dial. Max 0 A. TKS6 Electronic thermostat. Alternating contact. External dial. Max 6 A. Valves and water regulations VR20 Valve set containing AV20 stop valve, JVF20 adjustment valve, TRV20 3-way valve, SD20 electronic actuator and BPV0 by-pass valve. VR25 SD0 SD20 GCT02 Valve set containing AV25 stop valve, JVF25 adjustment valve, TRV25 3-way valve, SD20 electronic actuator and BPV0 by-pass valve. Electrothermal actuator for summer/winter function. For use with GTVV and GTRV valves. Electronic on/off actuator. For use with TVV-valves. Temperature controller for constant outblow temperature control. For use with GTVV and GTRV valves. 2 m capillary. GTVV20 2-way valve DN20 (3/4"). GTVV25 2-way valve DN25 ("). GTVV32 2-way valve DN32 ( /4"). TVV20 2-way valve DN20 (3/4"). TVV25 2-way valve DN25 ("). GTRV20 GTRV25 GTRV40 3-way mixing valve DN20 (3/4"). Incl. threaded nozzles (3 pcs). 3-way mixing valve DN25 ("). Incl. threaded nozzles (3 pcs). 3-way mixing valve DN40 ( /2"). Incl. threaded nozzles DN32 (3 pcs) and DN40 (3 pcs). GMV5 2-way magnetic valve DN25 (/2"). GMV20 2-way magnetic valve DN20 (3/4"). GMV25 2-way magnetic valve DN25 ("). AFT06 Anti-freeze thermostat with 6 m capillary for mounting on the heating coil. FH0820 Flexible hose DN20, length 0,8 m. FH0525 Flexible hose DN25, length 0,5 m. FH025 Flexible hose DN25, length m. Cables GMC0 GMC20 GMC30 GMC40 0 m RJ45 cable for connection of D705IR. 20 m RJ45 cable for connection of D705IR. 30 m RJ45 cable for connection of D705IR. 40 m RJ45 cable for connection of D705IR. Mounting kits GWB560 Wall bracket 560 mm. For S/M/G size units. GWB640 Wall bracket 640 mm. For B/BB size units. GP080 Threaded bars 000 mm. Size M8. Set of 2 pcs. GP080S Threaded bars 000 mm with vibration damper. Size M8. Set of 2 pcs. GP00 GP00S GCP GCO Threaded bars 000 mm. Size M0. Set of 2 pcs. Threaded bars 000 mm with vibration damper. Size M0. Set of 2 pcs. Covers for threaded bars. Set of 2 pcs. Oval shape cover for suspension, cables and pipes. Selecting mounting kits: Unit length No of mounting kits needed per air curtain 000 mm mm mm mm mm 4 For more information regarding control alternatives please contact Gelu-Frico. 23
24 GELU-Frico GmbH A Frico Group Company Dieselstraße Schlierbach Tel.: (0702) , Fax: (0702) 7684 info@gelu-frico.de 24
Thermozone RD. Air curtains for revolving doors
Electrical heat 6-36 kw Water heat Thermozone RD Air curtains for revolving doors Thermozone RD is an ideal solution for any environment with revolving doors. The air curtain is mounted on top of the door
More informationThermozone SF. Air curtains for vertical mounting in curved doorways
Electrically heated Water heated Thermozone SF Air curtains for vertical mounting in curved doorways Thermozone SF is an ideal solution for any environment with revolving doors or curved sliders. The air
More informationThermozone ADR 200/300 E/W
R Thermozone ADR 200/300 E/W Electrical heat 9-18 kw Water heat Lengths: 1, 1,5 and 2 metres Thermozone ADR 200/300 E/W Recessed air curtains for doors heights up to 3,5 metres ADR is our air curtain for
More informationFan Heater SW02 Quiet fan heater for connection to water in small buildings
heat model Heater Quiet fan heater for connection to water in small buildings Application is a compact fan heater with very low sound level designed for water connection. It is ideal for use where fan
More informationThermozone AC 300/WAC 300
Ambient, no heat Electrical heat 8- kw Hot water heat Lengths: and.7 metres Thermozone AC 00/WAC 00 AIR CURTAINS FOR DOORWAYS BETWEEN.5 AND.5 METRES The Thermozone 00-series consists of the AC variant
More informationOriginal instructions AR
Original instructions SE... 8 GB... 22 NO... 27 FR... DE... 6 ES... 4 NL... 46 IT... 5 RU... 56 Dimensions and connections AR20/AR25 M8 002/52 940/450 494 449 92 20 98 042/552 42 20 AR20/25A/E 40 275 DN5
More informationThermozone AD Corinte
R Thermozone AD Corinte Ambient, no heat Electrical heat 15 22,5 kw Water heat Vertical: 2,2 and 2,5 metres Horizontal: 1,7 and 2,2 metres Thermozone AD Corinte Air curtains for doors with heights of up
More informationFan heater SWT Ceiling mounted fan heater with water heat
Fan heater heat 3 models Fan heater Ceiling mounted fan heater with water heat Application The fan heater is used for heating entrances, stores, industrial premises, workshops, sports halls, garages and
More informationFan heater Panther Powerful fan heater for large premises
3 20 30 Electrical heat 5 models Fan heater Panther 20-30 Powerful fan heater for large premises Application Panther 20 30 is a range of powerful and quiet fan heaters for stationary use. They are intended
More informationAIR CURTAINS. Air curtains with integrated control panel and remote control. Air curtains without heating, with electric heating or water heating
Air curtains Air curtains The air curtains from VEAB create an effective, separating air trap between two temperature zones, for the entrances of department stores, public spaces, offices, etc. During
More informationWOLF WARM AIR CURTAIN
TECHNICAL DOCUMENTATION WOLF WARM AIR CURTAIN TL-2 30m 3 /h TL-2 WARM AIR CURTAIN Additional silencer mat in the discharge section Attractive intake grille with rectangular perforations, self-centring
More informationComfort Air Curtains with in-built dynamic advertising
Comfort Air Curtains with in-built dynamic advertising www.stavoklima.eu Li-DR Air Curtains Li-DR Contents Contents: page Introduction... 2 Air Curtains Li with in-built dynamic advertising (DR)... 3 Description
More informationFan heater Panther WALL MOUNTED FAN HEATER
Electrical heat 6 30 Fan heater WALL MOUNTED FAN HEATER 8 models is a range of silent and efficient fan heaters for fixed installation. is available in two sizes with different outputs. 6 15 is designed
More informationAir curtains. For a comfortable indoor climate
Air curtains For a comfortable indoor climate Welcome to the Frico air curtain catalogue! Our ultimate ambition is to give you the best possible support and the finest technical solutions. With this catalogue
More informationAir curtains. For a comfortable indoor climate
Air curtains For a comfortable indoor climate The full range Our complete range of air curtains gives you all possibilities to get comfort and save energy in your entrance or opening, with a modern and
More informationElztrip EZ100 Single panel radiant heater for offices, shops etc.
600-1500 W Electrical heat 3 models Single panel radiant heater for offices, shops etc. Application 00 is intended for total and supplementary heating as well as protection against cold draughts from windows
More informationRecessed. Air Curtain. Fig 1. Recessed air curtain
the future of space conditioning recessed www.frenger.co.uk an FTF Group Company Recessed Introduction These recessed s create an air barrier, which helps to prevent cold draughts thus creating a comfortable
More informationiq Star LYRA II chilled beam cassette
iq Star LYRA II chilled beam cassette Key features Ventilation Heating and cooling Compact chilled beam Adjustable induction Flow Pattern Control Integrated control In option: Demand Controlled Ventilation,
More informationTechnology for life. Unit heater LH
Technology for life. Unit heater 1 2 Contents Contents... Page Basic unit: casing, fan, motors... 4 Basic unit: heat exchanger... 5 Performance tables 25...6-7 Performance tables 40...8-9 Performance tables
More informationCHILLED BEAM CASSETTE IQ STAR LYRA
CHILLED BEAM CASSETTE IQ STAR LYRA TECHNICAL CATALOGUE 2 IQ Star LYRA Chilled beam cassette - Technical catalogue IQ STAR LYRA CHILLED BEAM CASSETTE The LYRA chilled beam cassette is a compact chilled
More information8/S1 AIR CURTAINS SONATA, SONATA-V. v 1.0 (en)
8/S1 v 1.0 (en) AIR CURTAINS SONATA, SONATA-V www.klimaoprema.hr 1 TABLE OF CONTENTS Air curtain Sonata 3 Technical characteristics 3 Design characteristics 5 Installation 6 Control 6 Accessories 7 Electrical
More informationElztrip EZ100. Elztrip EZ100. Single panel radiant heater for offices, shops etc. Product specifications
Single panel radiant heater for offices, shops etc. 3 models 3 600 1500 W Application 00 is intended for total and supplementary heating as well as protection against cold draughts from windows in environments
More informationAC25. Art.nr:
GB Installation and maintenance instruction for air curtains IMPORTANT: Read these instructions before the product is installed and used. Save the instructions for future use...2 Art.nr: 172785-01 Assembly
More informationINDUSTRIAL AIR CURTAIN. IndAC 2
INDUSTRIAL AIR CURTAIN IndAC IndAC industrial air curtain High climate separation efficiency with the IndAC industrial air curtain Optimal climate separation The Biddle IndAC industrial air curtain, is
More informationCUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams
Integrated chilled beams Key figures Connections: 1x mm, 2x mm Airflow: 5-60 l/s Pressure range: 40 - Pa Size: 293 x 200 mm (WxH) Length: 1192 or 1792 mm Total effect: up to 1200W Cumulus is available
More informationNEW RANGE OF WARM AIR CURTAINS
NEW RANGE OF WARM AIR CURTAINS stay connected and informed in real time www.france-air.com CONTENTS SELECTION GUIDE 3 HARMONY ONE EVO Compact single-phase warm air curtain 4 REGULATION 5 HARMONY Visible
More informationOriginal instructions. Panther 6-15 kw
Original instructions 6-15 kw SE... 8 GB... 10 NL... 12 IT... 14 ES... 16 FI... 18 DE... 20 FR... 22 NO... 24 RU... 26 PL... 28 6/15 Fig 1. Bracket 100 ø7 520 90 ø6,5 ø14 450 510 Fig 2. Ceiling Wall 30
More informationEnergy-efficient heat source provides comfort in large rooms
AIR HEATER NOZ NOZ air heater Energy-efficient heat source provides comfort in large rooms When it comes to providing large, and often high buildings, with the best possible source of efficient heating
More informationCarisma Fly. Made in. Italy. Wall-mounted Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT.
Made in Italy Air Conditioning Wall-mounted Fan Coil QUALITY MANAGEMENT SYSTEMS ISO 9001 - Cert. n 0545/5 www.eurovent-certification.com www.certiflash.com ENVIRONMENTAL COMFORT CONTENTS Introduction Version
More informationiq Star LYRA II chilled beam cassette
Key features The LYRA II cassette is an active chilled beam for ventilation, cooling and heating. This diffusion system offers high flexibility thanks to the combination of Flow Pattern Control, Coanda
More informationOriginal instructions AGI4500/6000
Original instructions AGI4500/6000 SE... 18 GB... 21 NO... 24 FR... 27 DE... 31 ES... 35 NL... 39 IT... 43 PL... 47 RU... 51 SE Introduktionssidorna består huvudsakligen av bilder. För översättning av
More informationT-RECESSED RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS
T-RECESSED RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING INSTALLATION Thermoscreens Ltd St. Mary s Road Nuneaton Warwickshire
More informationWATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ
WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ SERIES: EWCBZ - Heat pump MODELS: 70, 80, 00, 0, 60, 00, 40, 00, 50 COOLING CAPACITIES from 5,9 kw to 78,5
More informationSIRe Competent Air Curtains Water With quick guide. SIReAC. For wiring diagram, please see p Original instructions
Original instructions SIRe Competent Air Curtains Water With quick guide SIReAC SE... 2 GB... 19 DE... 36 FR... 54 For wiring diagram, please see p.71-73 For more languages, please see www.frico.se SIRe
More informationDesign vertical air curtain. Tubex, Tubex XL.
Design vertical air curtain Tubex, Tubex XL www.stavoklima.eu Description and technical data Design vertical air curtain Tubex, Tubex XL The design of the Tubex and Tubex-XL door air curtain makes it suitable
More informationAIR CURTAIN T SURFACE MOUNTED RANGE
AIR CURTAIN T SURFACE MOUNTED RANGE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS English T990009-- UK (v9) Page CONTENTS Page CONTENTS... ELECTRICAL SAFETY... SPECIFICATIONS.... INTRODUCTION...
More informationPHV-RECESSED RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS
PHV-RECESSED RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING INSTALLATION Thermoscreens Ltd St. Mary s Road Nuneaton Warwickshire
More informationIndustrial infrared heater IR For premises with large volumes and high ceilings
Electrically heated 3000 6000 W 3 models Industrial infrared heater For premises with large volumes and high ceilings Application is suitabe for total or supplementary heating of premises with large volume
More informationCHILLED ROOM AIR CURTAIN. IsolAir
CHILLED ROOM AIR CURTAIN IsolAir IsolAir chilled room air curtain Climate separation without heating Optimal climate separation The Biddle IsolAir chilled room air curtain is the perfect solution for internal
More informationPolaris-I-60. active chilled beam. the future of space conditioning
the future of space conditioning Polaris-I-60 active chilled beam Function Cooling and supply air with two-way air distribution Available with heating and integrated controls Application Offices, hotels,
More informationFan heater Panther 6-15 Efficient fan heater for medium size premises
Fan Heater 6-15 3 6 15 kw Riscaldamento elettrico 5 modelli Fan heater 6-15 Efficient fan heater for medium size premises Applicazioni 6-15 è una gamma di termoventilatori molto silenziosa ed efficiente
More informationMini Catalogue air curtains radiant heaters fan heaters convectors controls
Mini Catalogue 2007 air curtains radiant heaters fan heaters convectors controls 2007 Contents Frico 4 Thermozone Air curtains Introduction 6 Thermozone guidelines 7 Thermozone AD 100, ADA 10 Thermozone
More informationDX AIR CURTAIN. SensAir
DX AIR CURTAIN SensAir Biddle and Daikin Complete climate system Since 2006 Biddle and Daikin have joined forces to provide a complete climate system for shops and public buildings. By combining Biddle
More informationenergy efficient air curtains technical data and controllers
energy efficient air curtains technical data and controllers Versatile are delighted to introduce the following door curtains manufactured by LSA. LSA are a market leader in Europe in the manufacture of
More informationAir handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses
REC Temovex 4S-EC-RS Experts on indoor climate in low-energy houses RT 4S-EC-RS REC Temovex 4S-EC-RS ECO2 control system for low-energy and passive houses Comprises: - Air flow boost for warm and cold
More informationCONDOR. Supply air ceiling QUICK FACTS
Supply air ceiling QUICK FACTS 00% flexible spread pattern High induction rate Can be cleaned Diffuser modules 595 x 595 mm Available in alternative colours VariZon air distribution system A I R F L O
More informationCarisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT
Made in Italy Air Conditioning High Wall Fan Coil -ECM QUALITY MANAGEMENT SYSTEMS ISO 9001 - Cert. n 0545/5 www.eurovent-certification.com www.certiflash.com ENVIRONMENTAL COMFORT CONTENTS Introduction
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL
INSTALLATION, OPERATION AND MAINTENANCE MANUAL Air Curtains RUND Please, read these instructions carefully before attempting installation SECURITY ADVISE SYMBOLS Attention, Danger, Safety Advice! Danger
More informationThe green and friendly entrance. Comfort air curtains Model CA 2
The green and friendly entrance Comfort air curtains Model CA 2 Energy saving and userfriendly air curtain Model CA 2 is the newest addition to the series Biddle comfort air curtains. It is Biddle s conviction
More informationFan coil unit KL. Wall unit Ceiling unit
Fan coil unit KL Wall unit Ceiling unit Description Wall unit with casing, top discharge 7 unit sizes at an air volume of 150-1077 m³/h, heating outputs up to 13,4 kw, cooling outputs up to 6 kw Heating/cooling
More informationDOORS P -SERIES. Shop & Business MADE OFAIR. The smart way for Shop & Business TEDDINGTON AIR CURTAIN SYSTEMS FILTERLESS OPERATION
FILTERLESS OPERATION P -SERIES The smart way for Shop & Business Equipped with the CORRIGO air discharge system Shop & Business DOORS MADE OFAIR The smart way of saving energy. Expensive, heated air often
More informationAir Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses
NEW! REC Temovex Blue 4 Experts on indoor climate in low-energy houses REC Temovex Blue 4 Third generation of our Temovex units! - Dual counterflow heat exchangers with over 9% efficiency * - SFP < 1,
More informationTECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT
1. GENERAL INFORMATION 1.1 Applications page 2 1.2 Operation» 2 1.3 Performances» 2 1.4 Product range» 2 1.5 Selection software» 2 2. DIMENSIONS AND WEIGHTS» 3 3. COMPONENTS 3.1 Structure» 4 3.2 Coils»
More informationRadiator Valve Program
Radiator Valve Program Heat seeks cold faster when the temperature difference is greater. Lowering the temperature of a room reduces the amount of heat leaving the room (heat loss). Installing thermostats
More informationPrimo Hotel. General. Indoor climate units for hotel rooms
Indoor climate units for hotel rooms General Primo Hotel indoor climate unit Ceiling-mounted indoor climate units for ventilation, cooling and heating High capacity; occupies little space Dry system without
More informationSLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual
u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL
INSTALLATION, OPERATION AND MAINTENANCE MANUAL Air Curtains MAX Please, read these instructions carefully before attempting installation SECURITY ADVISE SYMBOLS Attention, Danger, Safety Advice! Danger
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL
INSTALLATION, OPERATION AND MAINTENANCE MANUAL Air Curtains: WINDBOX (M, ECM, G, ECG), KOOL (M, ECM, G, ECG), DECO (M, ECM, G, ECG), DAM (M, ECM, G, ECG) Please, read these instructions carefully before
More informationAIR CURTAIN HX RECESSED RANGE
AIR CURTAIN HX RECESSED RANGE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS English 990098-- Page CONTENTS CONTENTS... ELECTRICAL SAFETY... SPECIFICATIONS.... INTRODUCTION... 5. DELIVERY CONTENTS...
More informationUnits for suspended ceilings
X X testregistrierung Units for suspended ceilings Type, hinged induced air grille, water connections Active chilled beam with two-way air discharge and horizontal heat exchanger, suitable for grid ceilings
More informationWe have some on stock... GEA MultiMAXX Prompt. Unit Heaters Data & Facts. GEA Heat Exchangers / HVAC Systems
We have some on stock... GEA MultiMAXX Prompt Unit Heaters Data & Facts GEA Heat Exchangers / HVAC Systems Short Description/Overview of Capacity Quick solution for heating of industrial halls For more
More informationOriginal instructions. SIRe Basic Quick guide. SIReB
Original instructions Quick guide SIReB C SE... 7... 14 DE... 21 ES...28 FR... 35 IT... 42 NL...49 NO... 56 PL... 63 RU... 70 FI... 77 Wiring diagram - Basic SIReB SIReB1/B2/B1EC 230V~ SD230 SIReRTX (optional)
More informationLocal Climate. Global Comfort. air curtains radiant heaters fan heaters convectors controls
Local Climate. Global Comfort. air curtains radiant heaters fan heaters convectors controls Welcome to the Frico Mini Catalogue. The Catalogue displays an overview of the Frico range of Commercial Heating
More informationAir heater/cooler in combination with ground source heat pump
Swegon CASA Air heater/cooler in combination with ground source heat pump Installation, operation and maintenance instructions for design engineers, installation engineers and service personnel SDHWM_c_EN
More informationWOLF VENTILATION SYSTEM PRICE LIST
VENTILATION SYSTEM PRICE LIST JANUARY 2018 30m 3 /h THE EXTENSIVE EQUIPMENT RANGE from system supplier WOLF offers the ideal solution for commercial and industrial buildings, new build and modernisation
More informationIndustrial Air Heaters
HVH Horizontal or Vertical Discharge Fan Forced Unit Heater Industrial Air Heaters 2.6-50 kw 8,900 170,600 Btuh 208, 240, 277, 480, and 600 volt 1 or 3 phase Vertical or Horizontal Airflow Wall or Ceiling
More informationCHH - Active Chilled Beam. Halton CHH. Active Chilled Beam
Halton CHH Active Chilled Beam Combined cooling, heating, and supply air unit for suspended ceiling / bulkhead installation Excellent suitability for hotel guest rooms with high requirements for thermal
More informationFlush-mounted room thermostat
3 078 Flush-mounted room thermostat, for CAV / VAV heating and cooling systems, for AHU systems, for universal heating and cooling systems RDU340 Modulating PI control Control depending on the room or
More informationUniTrane Terminals. High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line Blower coil: B-Line. Product Presentation September 2016
UniTrane Terminals High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line Blower coil: B-Line Product Presentation September 2016 Agenda Product overview Key features Product range Controls Emissions Accessories
More informationFresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.
Fresh air unit ALB ALB it s simple and so easy! Air supplied through a heater and filter in a single unit. The ALB fresh air units from Helios provide comfortable room temperatures. Fresh outside air is
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL. Air curtain SMART
INSTALLATION, OPERATION AND MAINTENANCE MANUAL Air curtain SMART Read instructions carefully before attempting installation. Deliver this manual to end user. SECURITY ADVISE SYMBOLS Attention, Danger,
More informationTEDDINGTON AIR CURTAIN SYSTEMS L -SERIES. The smart entrance for Shop & Business. Equipped with the CORRIGO air discharge system
L -SERIES The smart entrance for Shop & Business Equipped with the CORRIGO air discharge system Doors Made ofair The smart energy-saving entrance. An air curtain system which balances moderate output with
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL
INSTALLATION, OPERATION AND MAINTENANCE MANUAL Air curtains ROTOWIND, INVISAIR Please, read these instructions carefully before attempting installation SECURITY ADVISE SYMBOLS Attention, Danger, Safety
More informationTECHNICAL SPECIFICATION
VALLOX-product code: HVAC code: 358500 L 35850 R 79076 L 79077 R SOUND ATTENUATOR (OPTIONAL) IVALLOX 252 WATER OPERATED POST- HEATING UNIT (OPTIONAL) ELECTRICAL POST-HEATING UNIT (OPTIONAL) ELECTRICAL
More informationHigh wall fan coils Climmy FHW/FHW-ECM. Technical Catalogue
High wall fan coils Climmy FHW/FHW-ECM Technical Catalogue Versions and Main components MODELS WITHOUT ELECTRIC HEATER All versions are available without valves, with 2 way valve or with 3 way valve fitted
More informationDual Pressure Controls
PRESSURE CONTROLS Dual Pressure Reset Hp/Lp Range Differential kpa kpa Ranco Dual Pressure G0048 017-8711* -30 to 700 700 to 3000 62 to 393 350 bar fixed G0056 017-8701 -30 to 700 700 to 3000 62 to 393
More informationInstallation, Operation & Maintenance Instructions Document Ref:
Series AM Fan Convectors Installation, Operation & Maintenance Instructions Document Ref: Dunham-Bush Ltd, Downley Road, Havant, Hants PO9 2JD 023 9247 7700 info@dunham-bush.co.uk 121-000-001-A UK:www.dunham-bush.co.uk
More informationFlush-mounted room thermostats
s 3 RDF300, RDF300.02, RDF340 RDF600 076 RDF400.01 RDF600 Flush-mounted room thermostats RDF300 RDF340 RDF400 for 2-pipe, 2-pipe with el. heater and 4-pipe fan coil units for use with compressors in DX
More informationVA G 052 S
763.576.3200 SPEC-00746 D763.422.2211 COOLING SEALED ENCLOSURE COOLING AIR CONDITIONERS Sealed Enclosure Cooling Air Conditioners V-SERIES COMPACT AIR CONDITIONERS VA06 Indoor Model 400 and 600 Watts INDUSTRY
More informationTechnical documentation Fan coil unit
Technical documentation Fan coil unit KL wall and ceiling unit Description Wall unit with casing, top discharge 8 unit sizes at an air volume of 150-1077 m³/h, heating outputs up to 13,4 kw, cooling outputs
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL
INSTALLATION, OPERATION AND MAINTENANCE MANUAL Air Curtains: RECESSED WINDBOX (M, ECM, G, ECG), RECESSED COMPACT (M, ECM, G, ECG), RECESSED DAM (M, ECM, G, ECG) Please, read these instructions carefully
More informationCASSETTE UNIT. Comfort Circle
CASSETTE UNIT Comfort Circle Comfort Circle cassette unit All-round comfort With today's energy prices, building owners are increasingly aware of the need for an efficient climate system to heat or cool
More informationVA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners
V-Series Mid-Size Air Conditioners (Now done by MGDC) VA08 Indoor Model 1200, 1500 and 2000 Watts INDUSTRY STANDARDS IP 56 Internal Air Loop IP 34 External Air Loop APPLICATION Industrial drive enclosures
More informationXLA-C SERIES BASIC AIR CURTAINS OVERVIEW CHARACTERISTICS
BASIC AIR CURTAINS XLA-C : For many applications, such as in shops with large numbers of clients coming in and out, a traditional entrance door may act as a psychological barrier to customers that shop
More informationAIR CURTAINS VCS DESCRIPTION. 2VV s.r.o., Podìbradská 289, PARDUBICE, CZECH REPUBLIC, TEL.: +420/40/ , FAX: +420/40/
Page 1 DESCIPTION Page 2 Hanging elements Electric connection 1xPg21 2xPg16 Pit for capillary of thermostatic valve or for channel sensor Water inlet and outlet 1" Hanging elements Electric connection
More informationMini catalogue air curtains radiant heaters fan heaters convectors thermostats. Comfortable and energy efficient indoor climate.
Mini catalogue 2013 air curtains radiant heaters fan heaters convectors thermostats Comfortable and energy efficient indoor climate. Welcome Welcome to the 2013 edition of the Frico Mini Catalogue. We
More informationPassive chilled beams
X X testregistrierung Passive chilled beams Type with frame, with perforated metal facing without perforated metal facing, RAL 9005, black Passive chilled beam in nominal lengths of up to 3000 mm and with
More informationThermocassette HP RADIANT HEAT CASSETTES FOR CEILING MOUNTING
Electrical heat 300 600 W Thermocassette RADIANT HEAT CASSETTES FOR CEILING MOUNTING 10 models Radiant heater Thermocassette is appropriate for heating of rooms with ceiling heights up to 3 metres where
More informationManual Comfort Air Curtain
Manual Comfort Air Curtain Model DF Version 2.0 Original Manual English a COMFORT AIR CURTAIN... Contents 1 Introduction 3 1.1 About this manual 3 1.2 How to read this manual 3 1.3 About the unit 4 1.4
More informationUnits for suspended cei lings
. X X testregistrierung Units for suspended cei lings Type, hinged induced air grille, water connections Chilled Beams No. 09.2.432 Eurovent certification HYGIENISCH GETESTET V DI 6022 Tested to VDI 6022
More informationPARAGON. Compact comfort module. Key figures
Compact comfort module www.eurovent-certification.com www.certiflash.com Comfort module is the name of a new family of compact comfort modules especially designed for use in hotels and hospitals. provides
More informationMini catalogue air curtains radiant heaters fan heaters convectors thermostats. Comfortable and energy efficient indoor climate.
Mini catalogue 2014 air curtains radiant heaters fan heaters convectors thermostats Comfortable and energy efficient indoor climate. Welcome to the 2014 edition of the Frico Mini Catalogue. At Frico we
More informationVA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners
763.576.3200 SPEC-00747 D763.422.2211 COOLING SEALED ENCLOSURE COOLING AIR CONDITIONERS Sealed Enclosure Cooling Air Conditioners V-SERIES MID-SIZE AIR CONDITIONERS VA08 Indoor Model 1200, 1500 and 2000
More informationSABIANA ENVIRONMENTAL COMFORT. Air Conditioning Ceiling Air Conditioning Elegant
Air Conditioning Ceiling Air Conditioning Elegant ISO 00 - Cert. n 0/ Unit heaters Radiant panels Fan coils Air handling units Flues SABIANA ENVIRONMENTAL COMFORT Air Conditioning SABIANA ENVIRONMENTAL
More informationOptimal work climate with open doors. Industrial air curtains Model IndAC
Optimal work climate with open doors Industrial air curtains Model IndAC Industrial air curtain Optimal work climate During loading and unloading the door remains open, without the indoor climate being
More informationPRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h
PRODUCT DATA COMFORT 40 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 40 m /h COMFORT 40 Product description The Comfort 40 is an energy-efficient ventilation
More informationINDUSTRIAL AIR CURTAIN. IndAC 2
INDUSTRIAL AIR CURTAIN IndAC IndAC industrial air curtain High climate separation efficiency with the IndAC industrial air curtain Optimal climate separation The Biddle IndAC industrial air curtain, is
More informationCatalogue 2015 AHU N Range: VENTUS VS 10 - VS 650
Catalogue 2015 01 VTS GROUP 1.1 VTS: Manufacturer No. 1 in the world 1.2 3 constituents of success 02 2.1 Water heaters 2.2 Product range 2.3 Technical parameters 2.4 Destratificator VR-D 03 CONTROLS
More informationFINESSE. Full manual INSTALLATION. VCF-B-xxx-... VCF-C-xxx-... B
EN FINESSE VCF-B-xxx-... VCF-C-xxx-... Full manual INSTALLATION B01-0211-0713-15 2 1. BEFORE YOU BEGIN Meaning of symbols in the manual: SYMBOL ATTENTION! Warning/caution MEANING DO NOT OVERLOOK! Important
More informationQZHW Fan Coil Unit. Key features. Specifications
Key features High wall installation Cooling ( pipes) Low noise level Electrical heating coil ECM version for low energy consumption QZHW is a high wall fan coil unit available in sizes and many different
More information