AIR CONDITIONER POWER PLANT

Size: px
Start display at page:

Download "AIR CONDITIONER POWER PLANT"

Transcription

1 AIR CONDITIONER POWER PLANT

2 GENERAL FEATURES GENERAL FEATURES Fantürk air conditioner power plants are produced 28 different sections. Flow range is between 900 m3/h m3/h for refrigeration and ventilation. Aim of heating, flow range is between 900m3/h m3/h. Fantürk air conditioner power plants are modular structure and have double paries board. According to request and implementation, Rockwool,glass woolor or polyurethane isolation panels can be produced like 50 mm or 60 mm gauge. Outer surface is coloured metal sheet which is RAL Metal sheet can be used galvanization or stainless related to requested or implementation Outer surface is smooth and ıt can be clean very easily and prevented dust deposit Fantürk air conditioner power plants framewok are consisted of strong structure with electrostatics klin coloured aliminium side view and plastic link components. Filter option should be chosen regarding to using environment and requirement of process. High efficieny can be get in filter and streamer owing to avoid leakage with special design Nowadays, Depending to requesting, Plate, impeller or battery type of heat recycling units are used Ventilator motot group can be chosen in such a manner efficiency aim to pay attention to air flow and total static pressure. According to aim of usage and design criterias, ıt can be selected stoop compact wing,airfoil or plug type. approved fan is used in performance test. Motors are in IP55 class. And these are suitable CE norms Tipping bodies ( using for air condition power plant ) are produced with using aliminium profil, aliminium wing and plastic gear. Gear is out of air flow.special shaped plastic gasket and tipping are impermeable

3 Program of chosing air conditioner power plants Fantürk air conditioner power plant program is about chosing of power plants, sizing of power plant, performance and technic datas With this program, you can unify your specifing materails,items and It gives us change to create your device. For each items, you can determine accessories. In selecting each items, You can see brand and model alternatives with price option. *Inside of option,you can select the best things as efficiency,price etc and You can also designate how many pieces are consist of your device as well as cell shape. *you can find technic report which is related to price, sized picture, device information. Fantürk power plant section and flow

4 FANTURK AIR CONDITIONER POWER PLANT MEASUREMENT

5 Quick Selection Table

6 Each detail has functionality and quality... TAPE Structure Special aliminium profile, interim profiler, panel are used in Fantürk air conditioner power plant. Aliminiun profiles are resistant to corrosion.profiles are consolidated with speacial designed plastic corners. Panels are standart size.and double size-partition and Rockwool,glass woolor or polyurethane are used for isolation Panels thickness are 50 mm or 60 mm. Panels outer tin plate is standardized RAL 9002 colour, and ıts inner side is produced stainless, galvanization colured tin plate tin plate s thickness is between 0,8-1,2 mm. Panels are detachable from outside of station. Plants are totaly plane. Panels are directly contacted with special screws to profile EPDM Sealant gaskets are glued between panels and profiles Between panels, interval profiles are used Isolation materials are filled with interval profiles On station, impermeadable sealed service door are built for essential areas. Upon your request, It can be also produced as observation glass The power plants base, according to power plants size, ıt can be one piece or partial with on the basis of cell. Air conditioner power plant is 100mm in low pressure, 150 mm in high pressure.for moving easily, there are pedestal removal holes Vehicles for using outside which can be proctected with special designed roof Power plant can carry out building site or partial or one- piece to provice convenience. Cells can be combined with special connection materials ACCESSORIES Lighting, observation glass, manometer, flexible joint, siphon, maitenance switch, damper motor, water protecting are used in air conditioner power plants.

7 FILTERS Fantürk air conditioner power plants s section complies with quality standards which are used in the sytyle of transition area. Filters can be removed easily thanks to casette type. Air leakage is prevented by approciate design.service door in the fitler cells are used for maintenance and replacement. Lighting, observation glass, manometer are used optionally. The importance of indoor air quality in air conditioninig plants are taken Different type or different efficiency filters are used.generally, type of filters are panel filter, bag fitler,metal filter, activated carbon filter, compact filter, hepa filter.panel filters are used as pre-filter. Filter materials are synthetict or metal. Panel Filters are used as pre-filter. Filter material is metallic or synthetic. Metal filters have an oil retention properties. We use filter classes; For synthetic materials : G2, G3, G4, metallic material To: G2, G3 For high-efficiency air filtration bag filters are used. Dust capacity is high. They should be used together with a filter for the Increase of the interior life. Boy bags by the air flow are 305 mm, 508 mm, 635 mm, as it varies.we use filter classes; G4, F5, F6, F7, F8 Compact filters are highly efficient filter. It should be used in conjunction with a prefilter. It has less space in exchange for that depth is 292 mm. Distribute air evenly to the filter construction is possible because the entire filter surface. filter class is used; F6, F7, F8, and F9. HEPA filters are used for hygienic environments. Efficiencies are very high. These filters are mounted after the fans must be used and necessarily with a prefilter. filter class used; H10, H12, H13, H14, respectively Activated carbon filters are used to soak in the air malodorous gas or vapor molecules ( exhaust fumes, the smell of rubber, alcohol, hydrocarbon, chlorine, and other chemicals, such as the odor from the manufacturing process). Hydrogen sulfide, sulfur dioxide, etc. As an alternative model is available for the absorption of the odor of other industrial processes, it should be used with a pre-filter to increase the service life. Suction -Mix- blowing Cells Damper sections are dimensioned in accordance with the air velocity. As standard ; aerofoil structure, the dampers are used opposite wing. Dump tape and wings of the material is aluminum. sealing air leaks using the blade edges are minimized. Dampers are manufactured according to the manual, or servo - motor control. Optional servomotor, rain protection and flexible connections can be installed. Damper sizes are standardized according to the type of plant has been designed to spend 100% air flow.

8 Heat Recovery System Today, energy efficiency is of paramount importance. Therefore, central air conditioning heat began to be preferred to use the recycling unit. Fantürk central air conditioning coil, plate and rotary heat recovery units are used. Overall yield; the coil type heat recovery units, %, 40-60% in the plate type, rotor type is % Streamer Heat Recovery Double coil heat transfer and heat recovery coil in the exhaust and fresh air exchange is carried out through the fluid circulating in a closed circuit. Heat transfer from the air to water - water to air is performed. intermingling of fresh air and exhaust air is not in question. Ethylene glycol is used in areas with the risk of freezing. The circulation pump in the system and there is a need to balance tank. The exhaust side of the condensate pan is used. Plate Heat Recovery Cross-flow plate heat recovery elements, without having moving parts between fresh air and exhaust air to provide heat transfer. even at high pressure difference can be provided complete seal. It can operate between -30 C to 90 C. Aluminum plates, are made of epoxy-coated aluminum or stainless steel. To prevent freezing at low temperatures are manufactured by-pass damper. The exhaust side, A drain pan is mounted against condensation can occur. Rotary Heat Recovery They have a compact design and high thermal performance. heat transfer sheet with an aluminum plate on a wavy appearance when placed in a rotor is performed. V-belts driven rotor rotation is provided by an electric motor. Generally can be grouped into 3 types 1 - Condensation Heat Wheels: In standard comfort ventilation, heat by condensing the water vapor in the air drained is low-cost solution that enables recovery. 2) Heat - moisture-absorbing wheels: Standard comfort air conditioning applications, and humidity makes the heat transfer wheels with a special surface in the appropriate temperature range. 3)Entalpy heat wheels In climates with high temperature and humidity conditions are preferred. Dessikant padded surface coated with substances with moisture transfer in higher amounts. With pre-cooling and dehumidifying feature reduces energy spent on cooling. Thus, the smaller capacity chillers provide a significant amount of energy is used. Fill diameter is between mm. less space due to its compact structure. The temperature efficiency of the thermal wheels minutes 12 d / d are optimized according to the rotation speed.

9 It is increased by the application. If desired capacity controlled by the variable climates frequency converter speed control is performed. The request must be submitted in order of capacity control. There is a risk of freezing. Determination of the rotor air handling fan Location General features Fantürk air handling units are manufactured in 28 different sections. Flow range is 900 m3 / h - 145, 000 m3 / h for cooling and ventilation purposes.only for heating plants, that is m3 / h Fan position, Differential Pressure Zone and Sweep

10 Moisturizer The spot to the desired moisture content is achieved by moisturizers. Fantürk types of steamy air handling, filling type, isothermal gas-guzzling and atomizer humidification units are used. Steam Humidifiers It generates heat with electricity Electric Heater Fantürk electric heater is used as optional air conditioning plant. Risk of freezing is used in power plants in regions with high inputs. It is also used in power plants in sensitive systems that need immediate heating output. Electrical heating tape galvanized or optionally is manufactured from stainless steel. Elements are stainless steel. Protection class is IP43, respectively. Gradual or proportional control can be performed. It has CE certificate. automatic reset limit thermostat and heater as standard with manual reset safety thermostat is located. If the heater is recommended for 2-3 minutes more fans after stopping operation of the power plant it is over 30 kw of heat energy. Central air conditioning electric heater in the study or the fan is running at very low speed (1.5 m / six ) cases, it is imperative to take measures to prevent abandonment of the electric heater Heating and Cooling Coils Heating and cooling is performed with coils. Serpentine copper or steel pipes, wings aluminum, copper, steel, epoxy-coated aluminum or copper may be coated with epoxy. Direct expansion coils are manufactured from copper a tube collectors are copper and aluminum fin Serpentine tray is made of galvanized steel sheet. The test pressure is 20 bar. Hot and cold water pipe inlet - outlet of gear in coils ; angry water and steam coils, pipes and input and output mouth is flanged. It is produced so that it can easily be taken out for maintenance. Special bypass sheet with only air to pass through the coil surface. Air and water is designed as reverse flow for improved efficiency. Hot and cold water coils, water inlet from the bottom, the water outlet is over the top. Cooling coils inside the drain pan through the flush -mounted panel coil surface area is made available in an efficient manner. Condensate pan is manufactured from stainless steel dual slope. separator used to hold condensed water from the air after cooling coils. Serpentine and Service Aspects from mains water. Microprocessor controlled. Moisture vapor from the unit performs humidification with the help of steam distribution pipes in the plant. On-Off or proportional control staff from 1.5 to 130 kg / h, there are many models in the range.

11 Fillet Type of Humidifiers Evaporative humidifier air is passed through the wet pad. It soaked through circulation pump filling system. the level of efficiency of the humidifier used is 65% to 85% to 95%. 3.5 m / s in air speed above the humidifier cell separator is placed. Isothermal Gas Fired Humidifiers Thanks to Isothermal humidifiers Gas-fired gas burning compact structure, Isothermal vapor can produce. changing parts during assembly natural gas (G20 or G25), propane (G30) or butane (G31) can be burned. Isothermal steam humidifiers are installed outside and plant produced steam is directed into central steam distribution pipes. Atomizer humidifiers are very low energy consuming large quantities of steam generating device kg / h are models in the range. Proportional running, these devices are capable of connecting to multiple air handling units. It works with demineralized water. Water is sprayed through the spray to the pressure up to 75 bar and thus ensure that the air is completely involved. Per liter / hour spends about 4 watts of energy for humidification. The system conforms to DIN 1946 standards of hygiene. Such emollients are used by adiabatic cooling. Equipment : Frequency controlled pump Drain valves Control unit Stainless steel pulverizer Distribution pipes drift eliminators, Automatic column valves Silencers The noise level is of great importance in ventilation systems, silencers is reduced to help locality acceptable level. sound absorption coefficient varies according to the length of the muffler silencer used. Muffler cell galvanized or stainless steel sheets into rock wool consists of set out backstage. Muffler elements 20m / s is designed to deform the air speed. Fantürk air handling There are 6 different size silencer. Sound absorption capacity are given in the following table according to the size silencer. Sound Absorption Capacity Size by Silencer

12 Fans and Motors Each section in the various fan types in accordance with the air flow and total pressure drop is presented. International standards suitable for static and dynamic balancing of purpose and fans were tilted forward, depending on the customer s request, can be tilted backward or airfoil blades. Fan- motor group, depending on the total air volume and static pressure efficiency, low noise levels and minimum energy consumption is selected considering. fan - motor assembly for preventing the vibration device is connected with the spring isolator. Bush as standard in our apparatus, fixed diameter pulleys are used optionally variable diameter pulleys may also be used. SPZ, SPA, SPB and SPC belt types are available. Tensioning of the strap is provided with a special mechanism. The fans for service and maintenance cell has a service door safety shield. Special cases are plug type fans are used motor is directly coupled. Engines are IP55 protection class as standard, it complies with CE norms. The standard single speed motors, can also be used as optional double speed motors. frequency converters are available as accessories for motor speed control Fan Operating Modes Diffuser Diffusers; then from fans, filters, coil, the air in the presence of elements such as silencers are used to provide a homogeneous distribution on these elements.

13

14 References

15 References

16

Teknogen. Contents. Air Handling Unit Casing of the Unit Fan / Motor Damper Filter Cells Heating / Cooling Coil...

Teknogen. Contents. Air Handling Unit Casing of the Unit Fan / Motor Damper Filter Cells Heating / Cooling Coil... Air Handling Unit Contents Teknogen Who we are, what we do? Air Handling Unit... 1 Casing of the Unit... 2 Fan / Motor... 3 Damper... 4 Filter Cells... 4 Heating / Cooling Coil... 6 Electrical Heater Section...

More information

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation Air handling units KLASIK Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation KLASIK air handling units Customer oriented and unique

More information

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation Air handling units KLASIK Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation KLASIK air handling units Customer oriented and unique

More information

Centeral Station Air Handling Unit

Centeral Station Air Handling Unit Centeral Station Air Handling Unit CA Series www.windind.com www.windind.com The product range includes double skinned Air Handling Units, double skinned Fan Coil Units, and custom designed packaged roof

More information

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS RAE 1352 F.K + MV AIR R-407C FC Series RAE... F.K Cooling capacity from 77 to 289 kw - 2 circuits The air cooled chillers of RAE... F.K series, are designed for outdoor installation and are particularly

More information

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit HRV-IP Ceiling Type Heat Pump Heat Recovery Unit HRV-IP Ceiling Type Heat Pump Heat Recovery Unit Ceiling type heat pump heat recovery units are energy saving devices thanks to plate type heat exchanger

More information

CLIMACIAT. air HanDLIng UnIT: CLIMaCIaT. Air handling unit

CLIMACIAT. air HanDLIng UnIT: CLIMaCIaT. Air handling unit AHU for all applications Designed to meet the EN 13053 and EN 1886 standards The effective solution for service sector, industry and healthcare applications air HanDLIng UnIT: CLIMaCIaT represents the

More information

VERSO Air Handling Units

VERSO Air Handling Units Energy efficient solutions for profitable indoor climate VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P air handling units equipped with recuperation system

More information

AIR HANDLING UNITS. Revision AG 16-07

AIR HANDLING UNITS. Revision AG 16-07 AIR HANDLING UNITS UNIC sal is equipped to produce a wide range of COOLER Air conditioning and Refrigeration units, conforming to the international standards and works continually to improve its products

More information

Indholdsfortegnelse. Danvent Air Handling Units SERVICE MANUAL

Indholdsfortegnelse. Danvent Air Handling Units SERVICE MANUAL Indholdsfortegnelse Danvent Air Handling Units SERVICE MANUAL Service Servicing of the Air Handling Unit Your ventilation system is equipped with a Danvent Air Handling Unit (AHU) which will contribute

More information

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett

More information

MODULAR AIR HANDLING UNIT. Models: FAC / FMC / FBC

MODULAR AIR HANDLING UNIT. Models: FAC / FMC / FBC MODUAR AIR HANDING UNIT Models: FAC / FMC / FBC Contents Product Nomenclature... 2 Features... 4 Engineering Specifications... 13 Cooling Coil Performance Chart... 13 Heating Coil Performance Chart...

More information

Double Skin Casing Air Handling Units

Double Skin Casing Air Handling Units Double Skin Casing Air Handling Units Double wall with 25 mm insulation Modular design for clean process application flexibility all the requirements 2,000 40,000 CFM AUTUMN Air Handling Units incorporate

More information

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning : Direct expansion close control air conditioners with up-flow or down-flow air delivery. Cooling Capacity: 7 102 NEW SOFTWARE R410A rcgroupairconditioning E C A C UP FLOW DOWN FLOW MAIN FEATURES Precision

More information

The ultimate in air handling units: directly and indirectly fired

The ultimate in air handling units: directly and indirectly fired KLIMAT The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake

More information

CLIMACIAT AIRTOP. Air handling units. Very short delivery time Double wall with 50 mm insulation. Complete range meeting all the tertiary requirements

CLIMACIAT AIRTOP. Air handling units. Very short delivery time Double wall with 50 mm insulation. Complete range meeting all the tertiary requirements Excellent quality / price ratio Very short delivery time Double wall 50 mm insulation Complete range meeting all the tertiary requirements Air flow : 000 to 7 000 m 3 /h DESCRIPTION Casing Double wall

More information

VERSO Air Handling Units

VERSO Air Handling Units VERSO Air Handling Units Energy efficient solutions for profitable indoor climate VERSO Air Handling Units VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 1402 C O K AIR R-407C Series RAE... C K Cooling capacity from 81 to 250 kw - 2 circuits The air cooled chillers of RAE C K series, with centrifugal fans, are designed for indoor installation and are

More information

39G Air Handling Unit

39G Air Handling Unit 39G Air Handling Unit Air flow: 2000 ~ 60000 m³/h The Manufacturer reserves the right to change any produt specifications without prior notices Version: Supersede: Effective Date: CAT_39G_E-1307_02 CAT_39G_E-1205_01

More information

www.ecso-klimatechnik.de ECSO GMBH Wetterssteimstr. 53 D- 90471,.. Nurnberg, Deutschland e-mail: info@ecso-klimatechnik.de Tel/Fax: +49 (0) 911/818 9917 TABLE OF SYMBOLS OPERATING MODE OPTIONS VENTILATION

More information

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU) AIR HANDLERS Central Station (CS3) (Modular AL Frame AHU) Roof Mounted (RT) CONTENTS 1. CS3 Modular Aluminium Frame AHU : Unit Types 2. Casing Structure 3. Blowers and Drives 4. Coils 5. Options and Accessory

More information

Enjoy the Delighting Comfort Brought by High Air Quality

Enjoy the Delighting Comfort Brought by High Air Quality Enjoy the Delighting Comfort Brought by High Air Quality Untes air handling units meet the required level of indoor air quality while maintaining the humidity and the temperature under control. They ensure

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 201 C K RAE 482 C K AIR R-407C Series RAE... C K from 19 to 83 kw - 1 and 2 circuits The air cooled chillers of RAE... C K series, with centrifugal fans, are designed for indoor installation and are

More information

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw Air cooled chillers with brushless oil-free compressors R-134a RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw External installation with very low sound level Cooling circuit with

More information

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB T_SMT_0609_GB 4,9 49,5 kw Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans INDEX SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3 CE CONFORMITY... 3 WORKING

More information

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications

More information

Ultimate energy saving technology

Ultimate energy saving technology Ultimate energy saving technology CWT Chiller Series CWt purestream series water chillers The new CWT Purestream chiller range is specifically designed to meet the stringent cooling requirements of today

More information

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB Next P 6 112 kw COOLING 5 93 kw HEATING Heat pump air conditioners with upflow air delivery technicalcatalogue T_NXTP_0411_GB INDEX GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 4 MODEL IDENTIFICATION...

More information

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES COOLING CAPACITY FROM 76 TO 612 Kw 1 AND 2 COOLING CIRCUITS RAE 1702 F Kc + P2 28 Above picture is only indicative

More information

13 HYGENIC AIR HANDLING UNITS

13 HYGENIC AIR HANDLING UNITS 39HQM INDEX 1 GENERAL 3 2 STANDARDS 4 2.1 Mechanical Strength 4 2.2 Casing air leakage 4 2.3 Filter bypass leakage 5 2.4 Thermal transmission 5 2.5 Thermal bridges 6 2.6 Acoustic casing insulation 6 3

More information

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:

More information

The ultimate in air handling units: directly and indirectly fired

The ultimate in air handling units: directly and indirectly fired AHU The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake

More information

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup. SECTION 23 70 00- CENTRAL HVAC EQUIPMENT PART 1: GENERAL 1.1 PURPOSE: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.

More information

Double Skin Air Handling Units

Double Skin Air Handling Units Double Skin Air Handling Units With Screwless Cabinets Engineered to Deliver High Indoor Air Quality Double Skin Air Handling Units from the Experts Blue Star has over six decades of experience in offering

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING

More information

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65% Dry HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES Calculation of savings (for illustrative purposes) Operating scheme Note: power rates refer to 10,000 m 3 /h of air and

More information

Air Handling Units. Real HVACR people who understand your needs.

Air Handling Units. Real HVACR people who understand your needs. Air Handling Units Real HVACR people who understand your needs. Copyright HC Heat-Exchangers (PTY) Ltd. 1 Copyright HC Heat-Exchangers (PTY) Ltd. 2 About the HC AHU range HC Heat-Exchangers rich engineering

More information

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1 UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS GPE 802 Kc + CF + GP + MV + P1 130 Above picture is only indicative and is not binding. AIR R-410A

More information

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES Air to water chillers and heat pumps The water chillers range have been designed for small and medium residential and commercial applications. The water chillers are suitable for water outlet temperatures

More information

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw COOLROW Close control air conditioners for In-Row installation Cooling Capacity: 14 61 Available in versions equipped with: - BLDC inverter scroll compressor on board of the unit - Chilled water feeding

More information

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz EN Technical Catalogue Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: 321-1308 kw 50 Hz EKV/BS business Air cooled water chillers for outdoor installation. Flexibility in the

More information

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The

More information

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features: RL Packaged Rooftop Units, heat pumps and Outdoor air handling Units Features: Air-cooled condenser, water-cooled condenser, or patented AAON evaporative-cooled condenser, with capacities from 45-240 tons

More information

The ultimate in air handling units: directly and indirectly fired

The ultimate in air handling units: directly and indirectly fired AHU The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake

More information

TEXTILE AIR ENGINEERING EASY INSTALLATION HIGH PERFORMANCE ENERGY EFFICIENCY

TEXTILE AIR ENGINEERING EASY INSTALLATION HIGH PERFORMANCE ENERGY EFFICIENCY EASY INSTALLATION HIGH PERFORMANCE ENERGY EFFICIENCY AUTOMATIC ROTARY AIR FILTERS Self-cleaned rotary air filter can be used in various applications. General area of use is textile plants for filtering

More information

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS RAH 602 Ka + CF + GP 62 Above picture is only indicative and is not binding.

More information

next p dw next p dw rcgroupairconditioning

next p dw next p dw rcgroupairconditioning NEXT P: Heat pump air conditioners with upflow air delivery with built-in water/gas exhaustion heat exchanger Cooling Capacity: 7,5 7,0 Heating Capacity: 7, 04,0 A C rcgroupairconditioning R40A PLATE E

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions Dehumidifiers for radiant cooling systems with heat recovery 50 The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area

More information

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT 90% EFFICIENCY HIGHEST EFFICIENCY AIR HANDLING UNIT Packaged energy recovery solutions for Green Buildings Integrated Accumulator, controls and DX Cooling System CLEAN AIR SINCE 1963 Euroclima is a company

More information

The ultimate in air handling units: directly and indirectly fired

The ultimate in air handling units: directly and indirectly fired KLIMAT The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake

More information

Air Handling Unit. Air Handling Unit

Air Handling Unit. Air Handling Unit Air Handling Unit Air Handling Unit Comfort Air Handling Units Air Handling Units with Plate Type Heat Recovery Unit Air Handling Units with Rotary Type Heat Recovery Unit Hygienic Air Handling Units Package

More information

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL The Kitchen Cool by Hood Depot is a conditioned make up air unit design with flexibility, form and function kept in mind. Our unit offers a variety of configurations that allow the customer to customize

More information

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features: RZ PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS Features: Air-cooled condenser, water-cooled condenser, or evaporative-cooled condenser packaged rooftop units from 55-240 tons Water-source

More information

EUROVENT certified Air Handling Units:

EUROVENT certified Air Handling Units: EUROVENT certified Air Handling Units: 32 models with air volumes: from 2.000 to 110.000 m 3 /h Special execution for higher air volumes This leaflet contains a summary of the CTL series air handling units,

More information

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES Air to water chillers and heat pumps The water chillers range is an efficient and low-noise product designed for medium to big applications. The water chillers are suitable for water outlet temperatures

More information

Cooling Towers. Energy-efficient solutions for open circuit, closed circuit and double-cell cooling towers.

Cooling Towers. Energy-efficient solutions for open circuit, closed circuit and double-cell cooling towers. ENGIE Refrigeration supplies the right cooling for every process: from efficient chillers and modular re-cooling systems to turnkey solutions such as refrigeration containers or modules. Efficiency, sustainability,

More information

Ultimate energy saving technology

Ultimate energy saving technology Ultimate energy saving technology CWT Chiller Series CWt purestream series water chillers The new CWT Purestream chiller range is specifically designed to meet the stringent cooling requirements of today

More information

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies Pakistan s Largest Manufacturers of Air-Conditioners PACKAGE TYPE UNIT FOR MOBILE APPLICATIONS Provides Turnkey Projects Conceptual Planning to Commissioning of HVACR Projects THE LARGEST MANUFACTURER

More information

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort Application guide FLATAIR - FLCK/FLHK Providing indoor climate comfort MSL60E-0701 12-2006 Congratulations you have made a wise choice and we feel sure that it will meet your expectation INDEX CONTENTS

More information

NEXT DL NEXT DL. rcgroupairconditioning

NEXT DL NEXT DL. rcgroupairconditioning NEXT DL: Close control air conditioners with displacement air delivery with remote condenser, or built in water cooled condenser or for chilled water feeding Cooling capacity: 7,7 51,4 NEXT DL rcgroupairconditioning

More information

CHAPTER 4. HVAC DELIVERY SYSTEMS

CHAPTER 4. HVAC DELIVERY SYSTEMS CHAPTER 4. HVAC DELIVERY SYSTEMS 4.1 Introduction 4.2 Centralized System versus Individual System 4.3 Heat Transfer Fluids 4.4 CAV versus VAV Systems 4.5 Common Systems for Heating and Cooling 4.6 Economizer

More information

Easdale International INFINITY

Easdale International INFINITY Easdale International INFINITY Air flow from 800 to 0.000 m 3 /h APPLIED SYSTEM AIR HANDLING UNITS AHU N : 0.0.502 Range: Easdale International www.eurovent-certification.com www.certiflash.com Engineered

More information

Bulletin C6200 MAY Buffalo. Big Buffalo. Air Handling. Custom Applications

Bulletin C6200 MAY Buffalo. Big Buffalo. Air Handling. Custom Applications Bulletin C6200 MAY 20 3 Buffalo Air Handling Big Buffalo Custom Applications Buffalo Air Handling Big Buffalo The historic strength of Buffalo Air Handling is the custom designed air handling equipment

More information

Package Hygienic Air Handling Units. PHK Series

Package Hygienic Air Handling Units. PHK Series Package Hygienic Air Handling Units PHK Series 1 PHK Series PHK : Standard PHK HP : Heat Pump PHK TO : Clean Room Air Handling Unit Up to 11.000 m 3 /h Airflow Complying with DiN 1946/4 Hygiene Criteria

More information

ULTIMATE ENERGY SAVING TECHNOLOGY

ULTIMATE ENERGY SAVING TECHNOLOGY ULTIMATE ENERGY SAVING TECHNOLOGY CWM CHILLER SERIES CWM PURESTREAM SERIES WATER CHILLERS The new CWM Purestream chiller range is specifically designed to meet the stringent cooling requirements of today

More information

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 46 Above picture is only indicative and is not binding AIR FC The packaged air cooled chillers of RAS Kp series are suitable

More information

KELVIN Clim F497. Kelvin air conditioning

KELVIN Clim F497. Kelvin air conditioning KELVIN Clim F497 Cooling Capacity: 400 ~ 1260 kw Free-Cooling Capacity: 497 ~ 1492 kw Packaged air cooled liquid chillers with free-cooling system in A class energy efficiency for outdoor installation,

More information

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013 SECTION 15800 - AIR HANDLING EQUIPMENT 1.1 GENERAL A. All air handlers installed shall conform to the University of Rochester specification Guideline for Semi-Custom and Pre-Engineered Air Handling Units.

More information

AIR HANDLING UNITS MANDÍK

AIR HANDLING UNITS MANDÍK AIR HANDLING UNITS MANDÍK 2 CONTENTS MANDÍK, a. s. The Company... 3 Photo Gallery... 4 Unit Description... 6 Air handling unit parameters according to Eurovent... 7 Product Range of the Air Handling Units...

More information

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

Большая библиотека технической документации   каталоги, инструкции, сервисные мануалы, схемы. Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы. AIR BLUE AIR BLUE air conditioning Homes Easy to install and use, quiet, attractive,

More information

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01 b cool manufacturers of air-conditioning equipment ltd BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION Ver. 1.01 Ver. 3.02 01_18 BCool# 1 brt c/h r407c / r410a

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02

More information

TYPICAL CPA SPECIFICATIONS

TYPICAL CPA SPECIFICATIONS TYPICAL CPA SPECIFICATIONS 4/10/2017 UNIT CONSTRUCTION: Casing: The exterior casing of the unit shall be constructed of 18-gauge, G235 galvanized steel (optional stainless steel or aluminum), unpainted.

More information

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating. capacity: Heating capacity: 20,8 to 135,1 kw 22,6 to 144,7 kw Scroll compressors R-410A refrigerant Confi guration fl exibility Silent operation DESCRIPTION The AirDuo cooling units and are units which

More information

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw Multifunction chillers for indoor installation. Cooling Capacity: 22 222 Heating Capacity: 25 236 Scroll compressors EC Plug Fans Plate type heat exchangers EER up to 3,12 COP up to 3,84 ESEER up to 4,01

More information

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A Publication No. WT-CSX-0616A Central Station Air Handling Units Complete HVAC Capability Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels

More information

Double Skin Air Handling Units

Double Skin Air Handling Units Double Skin Air Handling Units With Screwless Cabinets Engineered to Deliver High Indoor Air Quality Double Skin Air Handling Units from the Experts Blue Star has over six decades of experience in offering

More information

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10 Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW Compressors Scroll Serie: Series: Emissione: Issue: SCAEY Catalogo: Leaflet: Sostituisce: Supersedes: DE 88 04/11 12/10 Index

More information

1.1 This section applies to air handling units for HVAC Systems.

1.1 This section applies to air handling units for HVAC Systems. AIR HANDLING UNITS GENERAL INFORMATION 1.1 This section applies to air handling units for HVAC Systems. DESIGN REQUIREMENTS 2.1 Design Criteria a. The decision to use modular central station air handling

More information

USE sizes Horizontal and vertical versions Single or double flow arrangement (side by side or superimposed)

USE sizes Horizontal and vertical versions Single or double flow arrangement (side by side or superimposed) 70. USE Units designed to meet air handling requirements in the widest variety of rooms Tertiary sector Shops Industry and processes Hospitals and rooms with controlled particle levels (Clean Concept version).

More information

ALL PRODUCTS BROCHURE

ALL PRODUCTS BROCHURE ALL PRODUCTS BROCHURE www.aaon.com d e d i c at i o n t o cust o m e r service since the founding of aaon in 1988, we have maintained our commitment to design, develop, manufacture and deliver heating

More information

39 HQ Air Handling Units AiroVision

39 HQ Air Handling Units AiroVision VDI 6022 39 HQ Air Handling Units AiroVision Assembly/Installation, Commissioning, Maintenance Manual Type tested Production monitored AHU N : 08.02.251 Range: 39HQ DIN 1946-4 EN 13053 2 Code No: B.8.1.3i

More information

CHAPTER 6 CONDENSING UNITS

CHAPTER 6 CONDENSING UNITS CHAPTER CONDENSING UNITS Unit Page MHA/K - MHA/K 8 0 - MRA/K 8-9 MRA/K 8 0 0 - FROM, KW TO KW. MHA/K AIRCOOLED CONDENSING UNITS AND REVERSIBLE CONDENSING UNITS WITH AXIAL FANS AND ROTARY/SCROLL COMPRESSOR.

More information

Chapter-8 Capacity Control of Refrigeration Systems

Chapter-8 Capacity Control of Refrigeration Systems Chapter-8 Capacity Control of Refrigeration Systems Chapter-8 Capacity Control of Refrigeration Systems ၈.၁ Compressor Control Chiller Control and Chilled Water Plant Control Refrigeration system control

More information

FULLY SELF-CONTAINED AIR CONDITIONING WITH INDUSTRIAL DURABILITY

FULLY SELF-CONTAINED AIR CONDITIONING WITH INDUSTRIAL DURABILITY C A P A C I T Y R U G G E D, I N D O O R/ R E A D Y T O T O T A L L O C A L M A T C H E D O U T D O O R D E S I G N I N S T A L L S U P P O R T E N V I R O N M E N T A L C O N T R O L Liebert Industrial

More information

AHU Plus. DX Air Handling Units

AHU Plus. DX Air Handling Units AHU Plus DX Air Handling Units AHU Plus DX DX Air Handling Units AHUPlusDX-TH: DX Air Hadling Unit with 100% Fresh Air AHUPlusDX -IGK: DX Air Hadling Unit with 100% Fresh Air and Heat Recovery AHUPlusDX-KH:

More information

CONTACT US. For more information,

CONTACT US. For more information, Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice. Trane ccsa, Atatürk Mah. Meriç Cad. No:5 Turkuaz Plaza D:43-53

More information

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ SERIES: EWCBZ - Heat pump MODELS: 70, 80, 00, 0, 60, 00, 40, 00, 50 COOLING CAPACITIES from 5,9 kw to 78,5

More information

DIVISION 15 MECHANICAL

DIVISION 15 MECHANICAL DIVISION 15 MECHANICAL A. GENERAL DESIGN CONDITIONS 1. Design occupied spaces to maintain 72 F and a space dew point temperature not to exceed 55 F. 2. Design classroom and office space buildings with

More information

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES Range 3.6 To 36.5 Tons 50Hz R22 TABLE OF CONTENT General features Page 3 Components features Pages 3 to 5 Compressors Condensers Condenser fans Evaporators

More information

CENTRAL SPLIT UNIT UNIC

CENTRAL SPLIT UNIT UNIC CENTRAL SPLIT UNIT UNIC sal is equipped to produce a wide range of COOLER Air conditioning and Refrigeration units, conforming to the international standards and works continually to improve its products

More information

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED EQV R-407C WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED Size Cooling Heating [kw] [kw] 5 1,9 2,2 7 2,4 2,5 9 2,6 2,5 15 3,3 3,2 17 3,7 3,7 REPLACE: BT02E008GB-01 The Versatemp EQV units

More information

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series Type of Compressors Compressor Rotary Scroll Reciprocating Screw Centrifugal Air Cooled Chiller 77 ~ 329TR (270 ~ 1156 kw) ACDX Series 100 ~ 520TR

More information

Cert. n Air Conditioning Vulcan Pro Air Handling Units

Cert. n Air Conditioning Vulcan Pro Air Handling Units Cert. n 0545 Air Conditioning Air Handling Units The calculation program for these units, developed for heating contractors and designers, is included on the SABIANA CD-ROM. The CD contains the entire

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -

More information

AIR HANDLING. B. Section Building Automation and Control System Guidelines. C. Section Air Cleaning Devices and Filters

AIR HANDLING. B. Section Building Automation and Control System Guidelines. C. Section Air Cleaning Devices and Filters 237300 AIR HANDLING PART 1: GENERAL 1.01 RELATED SECTIONS A. Section 230530 Clean Steam Generation B. Section 230900 Building Automation and Control System Guidelines C. Section 234100 Air Cleaning Devices

More information

Heat pump and energy recovery systems

Heat pump and energy recovery systems SBS5311 HVACR II http://ibse.hk/sbs5311/ Heat pump and energy recovery systems Ir. Dr. Sam C. M. Hui Faculty of Science and Technology E-mail: cmhui@vtc.edu.hk Oct 2017 Contents Basic concepts Air-to-air

More information

lindab we simplify construction Lindab Modular air handling units Connection, start-up and commissioning manual

lindab we simplify construction Lindab Modular air handling units Connection, start-up and commissioning manual Lindab Modular air handling units Connection, start-up and commissioning manual Connection, start-up and commissioning manual 1 General... 3 2 Warnings and Tips... 3 3 Functional sections... 3 3.1 Fan

More information

Main technical datas:

Main technical datas: DCS - DCVS Dry Coolers Frigosystem, the patent holder for free cooling and dual free cooling in single frame, present the new generation line of DRY COOLERS, born to satisfy the request of cost saving.

More information