1 VESTA LOG FIRE VLF45NG, VLF45NG, VLF45P, VLF45P Manual & Remote Operated Models THIS IS NOT A DO-IT-YOURSELF PRODUCT THIS APPLIANCE MUST BE INSTALLED BY A CORGI REGISTERED PERSON INSTALLATION, USERS AND SERVICING INSTRUCTIONS Article I. PLEASE LEAVE THESE INSTRUCTIONS WITH THE USER 0120 THESE PRODUCTS ARE APPROVED TO THE EUROPEAN GAS DIRECTIVE
2 Contents Page No. List of components 3 Appliance Data 3 GENERAL INSTALLATION REQUIREMENTS 3 Fitting the Appliance 4 Fitting the appliance into the optional Radiant Firebox 5 Additional notes for handset remote control model 6 Assembling the fire & the placing of the logs 8 COMMISSIONING 10 Check for spillage 10 Briefing the User 10 USERS GUIDE 11 Useful tips & recommendations 11 Operation of your appliance 11 Manual Appliances 12 Remote Appliances 13 Cleaning your fire 14 SERVICING & MAINTENANCE 15 Spares Parts list 16 Guarantee 17 Installation & Service Record 18 Important Notes Please read before undertaking the installation 1. This is not a Do it yourself product and it must be installed by a competent person. 2. The chimney must be swept before the appliance is fitted. 3. The Installation Instructions must be adhered to without exception. 2
3 Before fitting this appliance, ensure that the following list of components are enclosed (a) Vesta Burner unit (b) 1 Set Ceramic Base Pieces (1 Base, 1 LH Side, 1 RH Side, 1 Front, 1 Burner.) (c) 1 Log Set (4 Pieces) (d) Installation, User & Servicing Instructions (e) For Handset Remote Models only 1 Handset Control unit c/w 9V alkaline battery 1 Signal receiver (with mount) 1 Battery Charger c/w lead & jack plug 1 Rechargeable Battery pack & wiring harness APPLIANCE DATA VLF45NG (Manual) VLF45NG (Remote) VLF45P (Manual) VLF45P (Remote) Gas Type Natural Gas Propane Heat Input (Gross) (kw) Supply Pressure (mbar) Injector Size (mm) Injector Setting (High) (mbar) Injector Setting (Low) (mbar) Gas Connection 8mm Compression Fuse Rating (Amps) N/A 3 N/A 3 Weight (Kg) Dimensions of burner: 450mm wide, 250mm deep, 190mm high. GENERAL INSTALLATION REQUIREMENTS 1 The law demands that all gas appliances are installed by a qualified installer in accordance with the current Gas Safety (Installation and Use) Regulations. The installation must comply with these installation instructions and all relevant parts of Local and National Building Regulations or Building Standards (Scotland) (Consolidation) Regulations and those relevant recommendations of the following British Standards. BS 5871: Part 2 BS 8303 BS 5440: Parts 1 and 2 BS 1251 BS 6891 The current IEE wiring regulations, Local Building Regulations and the Building Standards (Scotland) (Remote Models only). These Installation Instructions must be adhered to without exception. 3
4 2 FIREPLACE See figure 1 The radiant fireboxes can be fitted to fireplaces which meet the dimensional requirements shown in figure 1. FIGURE 1 Basket installations require a fireplace large enough to accommodate the basket chosen. Decorative frets should have a minimum of 50cm 2 (8 sq. ins.) of free air space through the ash cover to ensure adequate air supply for both convection air and burner combustion. 3 THE HEARTH The hearth must be made of a non combustible material at least 12mm in thickness and must meet the dimensional requirements shown in figure 1. The Heating Appliances (Fireguards) (Safety) Regulations 1991 are part of the Consumer Protection Act. It is a criminal offence to fit a Euroglow Inset burner into a fireplace where the periphery of the hearth is less than 50mm (2 ) above the floor level. Under BS 5871: Part 2 the installation of a fender of 50mm (2 ) height will satisfy the height requirement. 4 THE CHIMNEY FLUE For radiant firebox installations the chimney should be of the open-flue type and have a minimum cross sectional dimension of not less than 175mm. For basket installations the cross section size and the height should be matched to the cross section of the fireplace opening (See BS 5871 Part 3). 5 The flue must have a minimum effective height of 3 metres. 6 No restrictor plate or flue damper is permitted. Where a variable damper is fitted, this must be removed or fixed permanently in the fully open position. 7 The chimney must be swept before the appliance is installed and a flue test in accordance with National Regulations must be carried out. 8 VENTILATION The room containing the appliance must have a permanent air vent of at least 100cm². The vent must be direct to outside air or to an adjacent room having a permanent vent of the same area. FITTING THE APPLIANCE 1 Check that the fireplace is large enough to accept the selected basket. See figure 1. 2 Check that the ignition system functions correctly. Push and turn the control knob and check that a spark is generated at the pilot burner. If no spark is evident then check the soundness of the leads. 3 Check the tightness of the nut at the control valve end of the thermocouple. CAUTION: Do not over tighten. 4 It is recommended that, before proceeding further, a simple smoke test be performed to check the condition of the chimney. Light a smoke match or a twist of rolled paper, hold it within the fireplace opening and observe the behaviour of the smoke. 4
5 If it is being drawn into the chimney proceed with the installation. If not, preheat the chimney over the period of a few minutes and recheck. If there is any doubt about the soundness of the chimney a smoke pellet should be used after preheating the flue and if smoke still fails to clear, further investigation of the chimney is required and the appliance MUST NOT be fitted. 5 The gas supply should be routed from the meter or cylinder to a point convenient to the fireplace. 6 Cut and form a section of 8mm pipe, only rigid and semi-rigid tube is acceptable and run this into the fireplace opening. If a concealed fitting is required, care must be taken to sleeve the supply pipe when fitting through masonry. 7 Place the appliance centrally within the fireplace opening. N.B. No part of the appliance should project beyond the vertical opening of the fireplace opening. 8 Using the nut and olive provided, connect the 8mm supply pipe to the combined pressure test point and isolator fitting. Gas Soundness Check 9 With the gas supply connected, all joints should be checked for gas soundness in accordance with BS NOTE: It is permissible to light the fire FOR SHORT PERIODS ONLY when the fire is not laid with ceramics and logs. FITTING THE APPLIANCE INTO THE OPTIONAL RADIANT FIREBOX 1 Check that the fireplace or recess is of the correct size to receive the radiant firebox. See Figure 1. Note: BS 5871 Part 2: requires a debris collection space of 12 dm 3. 2 It is recommended that, before proceeding further, a simple smoke test be performed to check the condition of the chimney. Light a smoke match or a twist of rolled paper, hold it within the fireplace opening and observe the behaviour of the smoke. If it is being drawn into the chimney proceed with the installation. If not, preheat the chimney over a period of a few minutes and recheck. If smoke still fails to clear, further investigation of the chimney is required and the appliance MUST NOT be fitted. 3 In either case, clear the recess of any loose material. Ensure that the base on which the firebox will stand is level and that the base of the recess and the hearth are horizontal and non-combustible. 4 Slide the firebox into the opening, ensuring that the flue outlet is unobstructed and give a clear passage for the products of combustion to the flue. (Do not seal at this stage.) 5 The firebox should be fitted in such a manner as to be removable, for the purposes of chimney-sweeping and easy removal of debris. 6 The gas supply should be routed from the meter or cylinder to a point convenient to the fireplace. 7 Decide whether the gas supply is to be routed through the sides or back of the firebox, or across the front of the fireplace. Grommeted holes are provided in the rear and side of the box. Having determined the position of the gas pipe the appropriate grommet can be pierced with a knife. Provision will have to be made to pass the pipe through the masonry of the fireplace. The supply pipe should be run to make removal for servicing easy. 5
6 8 Cut and form a section of 8mm pipe, only rigid or semi-rigid tube is acceptable, and run this into the fireplace opening. If a concealed fitting is required, care must be taken to sleeve the supply pipe when passing it through masonry. Exposed pipe within the fire opening should be wrapped, painted with bituminous paint, or be factory sheathed. 9 Seal the firebox into the fire opening using the sealing tape provided or a water based mastic. 10 Fit the burner unit into its mounting brackets within the firebox. 11 Prior to connecting the burner to the gas supply, it is advisable to blow out the pipe to clear any dirt that may be present and which could cause a blockage in the control valve or pilot. 12 Using the nut and olive provided, connect the 8mm supply pipe to the combined pressure test point and isolator fitting. 13 Complete the installation of the appliance as above. ADDITIONAL NOTES FOR HANDSET REMOTE CONTROL MODEL 1 The installation of the appliance should be carried out following the procedures as per the section entitled Fitting the Appliance on page 4. 2 After installing the burner, positions must be found for the battery pack and the Infra Red (IF) signal receiver. The fret and ash pan cover will have to be put in position to find the best place for these items. 3 Battery Place the battery pack on the hearth along the front of the fire just behind the ash pan cover. DO NOT PLACE THE BATTERY PACK UNDER THE FIRE. 4 Plug the small jack plug from the charger into its socket at the end of the battery pack and plug the charger into the mains and switch on to give the batteries a top up charge. FIGURE 2 6
7 5 Charging the battery pack The charger supplied with the battery pack is a true charger and will not overcharge the batteries. The charger has a built in switch so that it will switch off when the batteries in the pack are fully charged. The red LED on the front face of the charger will light when there is current passing to the batteries. FIGURE 3 6 The batteries can be charged either when FIGURE 4 they are run down and the fire will not light (the control box under the fire should emit a series of beeps if an attempt is made to light the fire when the batteries do not have sufficient charge) or on a regular basis as convenient to the user. The batteries used are of the nickel metal - hydride type that do not suffer memory problems if they are not discharged completely before being re-charged. A minute charge should be enough to enable the fire to be lit but a full charge will take several hours. It may be convenient to leave the charger connected overnight. DO NOT LEAVE THE CHARGER CONNECTED TO THE BATTERY PACK WHEN THE FIRE IS IN USE. 7
8 7 IR Signal Receiver The signal receiver should be placed on the hearth just behind the ash pan cover such that it is visible to the user operating the remote control handset. If the receiver is covered in any way the fire will not operate. The receiver is secured to a bracket with a screw which can be removed when the burner is taken out for service. The bracket should be fixed to the hearth with the double sided tape provided after having selected a suitable position for it with the fret and ash pan cover in position (See Figure 5). The signal receiver must be positioned on the bracket with the raised part facing the user. 8 Fitting the Battery to the Handset Before using the appliance remove the access cover in the rear of the handset and insert a 9-volt PP3 size battery. Connect the battery by pushing the connector on to the terminals. Make sure the battery is connected correctly. Replace the access cover. FIGURE 5 ASSEMBLING THE FIRE AND PLACING THE LOGS WARNING This product uses fuel effect pieces containing Refractory Ceramic Fibre (RCF), which are man-made vitreous silicate fibres along with fibrous glass and mineral wool. Excessive exposure to these materials may cause temporary irritation to eyes, skin and respiratory tract; consequently, it makes sense to take care when handling these articles to ensure that the release of dust is kept to a minimum. FIGURE 6 8
9 CAUTION All the ceramic components are fragile and should be handled with care. 1 The burner tray and base ceramics are illustrated in figure 6. Position the burner ceramic making sure that the holes are aligned with the burner ports. Take the front ceramic and place it on the burner tray in front of the burner ports. Lay the base ceramic on the ramp behind the front ceramic. Place the side ceramics either side of the base ceramic. 2 With reference to figure 7 on the following page, lay the logs as follows; a) Place the largest log in its moulded seat at the rear of the base ceramic. b) Place the small branch log in its seats on the left hand side and front ceramics and rest it on the upstand of the base ceramic. c) Place the log with a burnt cut-out on its seat on the right hand side ceramic. d) Place the small v-shaped log in position on the front ceramic and rest it on the large log and the front logs. FIGURE 7 9
10 COMMISSIONING When commissioning your appliance, remove the cap from the isolator fitting and unscrew the plug all the way out. Replace the cap making sure that the tab engages with the slot in the top of the plug. Tighten cap securely. Light the appliance in accordance with the instructions relevant to the appropriate control. (See following sections for details) CHECK FOR SPILLAGE 1 Before briefing the customer on how to use the appliance, a spillage test must be carried out with the appliance and decorative fret in position. The following procedure must be followed. 2 Close all doors and windows in the room or space containing the appliance. 3 Light a smoke match and pass completely along the front edge (and just inside the top edge) of the fireplace or firebox. A visual check should ascertain that all the smoke generated is drawn back into the firebox. 4 If there is evidence of spillage, the flue should be heated for a period of 5 to 10 minutes and the test repeated. BRIEFING THE USER 1 Demonstrate the full operation of the appliance to the customer, referring them specifically to the lay of the logs and the removal of soot, as described in these instructions. 2 Inform the customer that all cleaning procedures should be carried out only when the appliance is cold. 3 Leave these instructions with the customer. 4 Advise the importance of having the appliance serviced and the chimney checked for clearance of combustion products on an annual basis. 10
11 USERS GUIDE USEFUL TIPS AND RECOMMENDATIONS Once your fire has been fitted, the following recommendations are made to ensure you enjoy the best results from your purchase; 1 The installation of this appliance must be carried out by a qualified installer and in accordance with the requirements of the Gas Safety (Installation & Use) Regulations 2 The chimney must be swept before the appliance is installed and checked annually to ensure continued clearance of combustion products and that there is no excessive build-up of soot. 3 As with any fire, certain components will become hot in use, e.g. the decorative front fret. Care should be exercised when using the control of the appliance when it is hot. We also recommend that a fireguard, conforming to BS 6539 or BS 6778, be fitted for the protection of young children, the elderly or infirm. 4 When new, the ceramic logs may produce a slight odour, but this will completely vanish after a few hours of use. 5 Handle logs gently (See warning on Page 8). They are fragile. A soft brush can be used to clean them of any excess soot. UNDER NO CIRCUMSTANCES should logs be washed. 6 Never throw cigarette ends or other foreign matter onto the fire. 7 Never leave the house unattended, with the fire alight, for long periods. 8 Check periodically that the purpose-made ventilation is free from obstruction. 9 To obtain the best results from your log fire we recommend that the fire be serviced. In order that the terms and conditions of your warranty (see page 17) are met, this must be undertaken annually and the Service Engineer must complete the Service Record. (Page 18) 10 These instructions are provided to assist you to operate the fire correctly and should be kept in a safe place. 11 This appliance is intended for decorative purposes. 12 This appliance is fitted with a flue blockage device that will shut off the appliance in the event of abnormal flue conditions. This device is NOT a substitute for an independently mounted carbon monoxide detector. 13 It is a characteristic of the re-chargeable Nickel - Metal Hydride batteries that power the control system is that they deliver almost full power until they are nearly completely discharged. This means that the first indication that the battery pack needs charging is that the fire will emit a series of beeps when an attempt is made to light the fire from cold and the pilot burner will not remain alight. A 20 minute charge will probably be enough to light the fire but this should be followed by full charge as soon as the fire is not required. OPERATION OF YOUR APPLIANCE 1 It should be noted that your fire is fitted with a Flame Supervision Device, which cuts off the gas supply to your fire if, for any reason the pilot light is extinguished. It also monitors constantly the oxygen in the room. The pilot flame heats the thermocouple probe and allows gas to flow to the burners. If due to pilot failure, the thermocouple cools, no gas will flow to the main burner. If the fire is turned off or the flames go out, wait for AT LEAST 3 MINUTES before attempting to relight the fire. 11
12 2 When the fire is first lit, the flames tend to be rather blue in colour. Once the core of the fire becomes hot, the flames will become yellow and more lifelike. During this initial warm-up period it is recommended that the control remains in the MAX or HIGH position. This permits the fire to reach its optimum condition more quickly. 3 For convenience you will find with the appliance a card giving concise lighting instructions, please keep this in a safe place. For full details see the relevant appliance instruction on pages LIGHTING THE APPLIANCE Manual Appliances 1 Remove the ash pan cover (if fitted) below the decorative fret in the front of the fire. 2 Push in and turn the control knob (see figure 8) anti-clockwise to the PILOT position & hold in for several seconds to purge any air from the system. If the fire has not been used for some time or is new this may take half a minute or more as the air can only purge through the very small orifice in the pilot burner injector. During this purge time you can try lighting the pilot burner (see next paragraph) every ten seconds or so but after each attempt remember to return the control knob to the pilot position and keep it depressed. 3 Lighting the pilot burner is done by turning the control knob, still depressed, from the OFF position to the PILOT position when the spark generator will be heard to click as a spark is produced which should light the pilot burner. If the pilot does not light try again after a few seconds. The pilot may not light at the first attempt. Waiting a few seconds gives the spark generator time to recover. 4 Once the pilot burner is alight continue to depress the control knob for a further seconds and then release. The pilot should stay alight. If it goes out repeat the process, only this time keeping the control knob depressed for a slightly longer period. 5 Depress the control knob slightly and turn anti-clockwise to the MAX position. The main burner should now light. 6 Turn the control knob anti-clockwise to the MIN position. The flames will get lower but the main burner should remain alight. Turning the fire off 7 To turn off the burners, depress the control knob slightly and turn clockwise to the PILOT position. The main burner should go out but the flame should remain alight. 8 Depress the control knob slightly and turn to the OFF position. The pilot flame should go out. IMPORTANT FIGURE 8 After turning OFF, or if the pilot or the appliance go out for any reason, wait 3 minutes before attempting to relight. 12
13 Remote Appliances 9 Using the handset When using the handset make sure that it is pointed at the infra red signal receiver located under the front of the fire (the small black pad). Unlike a TV control the fire does not react to a quick press on the button on the handset control. The buttons must be pressed and held until the control box under the fire acknowledges the signal by emitting a 'beep' sound (this can take two or three seconds) and then released. When the handset is emitting a signal the yellow LED at the top of the control will flash. 10 Lighting the Fire See Figure 9 To light the fire press the OFF and the STAND BY buttons together on the handset until the fire control box answers with a 'beep' and then released. The fire will go through its start - up procedure by lighting first the pilot burner and then the main burner on high fire. This procedure takes about 30 seconds. If the fire does not light or there is no reaction when the two buttons are pressed, press the OFF button to reset the control and try again. 11 Adjusting the Flame Height To turn the fire from high to low, press and release the low fire button as soon as the 'beep' is heard and the flame height will reduce. If the fire is set at high and a flame height between high and low fire is desired, press and continue to hold the low fire button after the 'beep' has sounded. The flame height will gradually decrease. Release the button when the desired height of flame is achieved. To turn the fire from low fire to high fire press and (after the 'beep' is sounded) release the high fire button. To gradually increase the flame press and hold the button as described above for the low fire button. 12 Turning the Fire OFF To turn the fire off but leave the pilot burner alight press the STAND-BY button until the 'beep' is heard. Use this facility to conserve battery life if the fire is going to be used again later in the day. To turn the fire completely off press the OFF button. The STAND-BY button and the OFF button can be pressed when the flame is at any height. To light the main burner from the STAND-BY position press either the HIGH FIRE or LOW FIRE buttons. 13 Manual OFF Facility FIGURE Figure 119 If, whilst the fire is alight, the handset control is lost or its battery becomes discharged the fire can be turned off by pressing and holding the manual off button situated on the fascia underneath the front of the burner. This button disconnects the battery from the control box and the fire will go out after the button has been held in for about a minute. Care should be taken as the fret / ash pan cover as well the burner facia will be hot. 13
14 14 Replacing the batteries As stated above, the batteries are of the nickel metal - hydride type which have a long life and are able to be re-charged many times. Eventually, due to age and use, a point will come when they need recharging at inconveniently short intervals and they will have to be replaced. The batteries are AA size and should be of 1.2 volts and at least 1300mAH capacity. This type of battery is readily available through retail and trade outlets. 15 To change the batteries a) When the fire is cold lift away the ash pan cover. b) Locate the battery pack under its heat shield. c) Invert the battery pack and bend the securing tab outwards. Slide the battery holder out of the heat shield. d) Remove the batteries from their holder and replace with new batteries. Observe the correct polarity of the batteries in their holder. e) Slide the battery holder back into the heat shield and re-bend the securing tab. f) Plug the charger into the battery pack and to the mains. The red LED on the charger should come on. If it does not, check the polarity of the batteries and all connections. Charge the batteries overnight, or as indicated by the instructions that were included with the new batteries. CLEANING YOUR FIRE 1 Ensure that the fire is cold before undertaking any cleaning. Remember that heat is retained for some time after the fire is switched off. In normal use your fire requires only minimal cleaning. Soot may form on the logs but this is generally harmless and can easily be removed by lifting the relevant logs from the fire and cleaning them with a soft brush. If it is necessary to remove all logs for cleaning then any soot or debris should be removed from the ceramic element and from the burner. 2 As with all metal products, the trim on the fire may tarnish over a period of time. The metal finish is covered with a lacquer and should only be washed with mild detergent. On no account use any abrasives or metal polish on the trim. 3 If large pieces of debris are found in the fire, sufficient to alter the appearance or operation of the appliance, the chimney / flue should be inspected and the appliance serviced before further use. 4 In any event, the chimney should be checked annually to ensure continued clearance of the combustion products and that there is no excessive build-up of soot. 14
15 SERVICE AND MAINTENANCE WARNING This product uses fuel effect pieces containing Refractory Ceramic Fibre (RCF), which is man-made vitreous silicate fibres along with fibrous glass and mineral wool. Excessive exposure to these materials may cause temporary irritation to eyes, skin and respiratory tract; consequently, it makes sense to take care when handling these articles to ensure that the release of dust is kept to a minimum. The appliance should be serviced annually by a CORGI registered engineer. This is the basic procedure. 1 The ceramic pieces should be taken off the fire and shaken to remove any debris and soot particles but should only be cleaned if absolutely necessary. This should be done by gently brushing with a soft brush in a direction away from the person and any persons nearby. This operation should be performed outside facing downwind. A vacuum cleaner must not be used for this purpose. Badly damaged logs should be replaced. Replacement logs and ceramic pieces are available via our stockists. 2 The gas supply should be turned off at the combination pressure test point and isolator fitting. Disconnect the burner from the gas supply, remove any burner fixings and lift away the burner. 3 Remove all debris and soot from the burner and thoroughly clean the burner ports. 4 The pilot burner fitted is an oxygen depletion pilot burner and is the primary safety device on the appliance. It must therefore be replaced annually. After changing the pilot burner operate the spark generator and observe that the spark is satisfactory. 5 Lay the burner on a flat surface and remove, clean and replace the main injector. 6 Any soot or debris should be removed from the fireplace and flue. The flue should be inspected for soundness and a smoke test performed as described in the fitting section to check the condition of the flue. 7 Replace and fix the burner in position. Re-connect to the gas supply. Check all joints for gas soundness. 8 Light the burner and check that it functions correctly. Re-light the pilot burner. Check that the pilot flame is satisfactory. Check correct functioning of the thermocouple and magnet valve (housed within the control valve). This is done by turning the control knob to the pilot position and then blowing out the pilot burner. Time the period between the blowing out of the pilot burner and hearing the 'click' of the magnet valve closing. If this period exceeds 60 seconds the magnet valve will also have to be replaced. 9 Replace the burner ceramics and rebuild the fuel lay as described in the installation section. Light the fire and, after allowing it a few minutes to warm up, make final adjustments to the logs to obtain a satisfactory visual affect. AFTER REFITTING THE APPLIANCE CHECK FOR GAS SOUNDNESS AT ALL GAS JOINTS AND TEST FOR SPILLAGE. 10 The service record sheet is enclosed with these instructions and should be completed to maintain the validity of the five year warranty 15
16 SPARE PARTS LIST In the event of a part requiring replacement the parts list is as follows DESCRIPTION OXYGEN DEPLETION PILOT ASSEMBLY (NATURAL GAS ONLY). OXYGEN DEPLETION PILOT ASSEMBLY (L.P.G. PROPANE ONLY). GAS CONTROL BM VALVE (NATURAL GAS MANUAL) INC. PIEZO & HT LEAD GAS CONTROL BM VALVE (L.P.G. MANUAL) INC. PIEZO & HT LEAD GAS CONTROL BM VALVE (NATURAL GAS & L.P.G S/C) INC. PIEZO & HT LEAD SIT TANDEM 830 SOLENOID VALVE (NATURAL GAS & L.P.G. S/C ONLY) EXTERNAL SWITCH LEAD. BRASS WALL SWITCHPLATE. WHITE WALL SWITCHPLATE. LOG/CERAMIC SET BURNER TRAY. FIREBOX CERAMIC LINING. HIGH TEMPERATURE FIREBOX/STOVE PAINT SATIN BLACK CAN. BLACK MAGIC COAL/CERAMIC RESTORER CAN. SENSOR DOUBLE SOLENOID VALVE SENSOR HAND HELD UNIT SENSOR RECEIVER UNIT VERINE PART NUMBER P47 P48 P12 SPECIAL ORDER P12 SPECIAL ORDER P12 SPECIAL ORDER P97(22NG) SC13 SC2 SC3 VO28 H63 P55 P56 SC10 SC10H SC10R 16
17 GUARANTEE. 1. The appliance is guaranteed for one year from the date of purchase. 2. This guarantee is given subject to the following provisions:- a) The installation is carried out by a CORGI registered person. b) That the fireplace conforms to the requirements given in the Installation Instructions for this appliance. c) That our instructions covering cleaning and handling are adhered to. This guarantee does not cover mishandling. d) That the guarantee card supplied with every purchase is returned to us for registration within four weeks of the date of purchase with the details correctly filled in. e) That any part or parts on which a claim is made are returned to us postage paid for inspection. f) That our liability is limited to free replacement of the parts affected. g) The guarantee does not cover (1) Normal wear and tear. (2) Possible discolouration of polished parts. (3) Replacement of batteries. h) The remote battery pack, if fitted, is guaranteed against faults but battery life is not guaranteed as this is dependant on usage, the battery is also not guaranteed if it is damaged due to heat if the instructions on placement are not followed. 17
18 Installation & Service Record Please ensure that installer completes the installation record below INSTALLATION RECORD Appliance Supplied by:... Installation Date: Serial No.:.... Installed By:.....CORGI No.:.. Signed by Installer:.. RECORD OF 1 st SERVICE RECORD OF 2 nd SERVICE Serviced by: CORGI No.:... Service Date: Signed:..... Comments: Serviced by: CORGI No.:... Service Date: Signed:..... Comments:.... RECORD OF 3 rd SERVICE Serviced by: CORGI No.:... Service Date: Signed:..... Comments: RECORD OF 4 th SERVICE Serviced by: CORGI No.:... Service Date: Signed:..... Comments:.... RECORD OF 5 th SERVICE Serviced by: CORGI No.:... Service Date: Signed:..... Comments: RECORD OF 6 th SERVICE Serviced by: CORGI No.:... Service Date: Signed:..... Comments:.... RECORD OF 7 th SERVICE Serviced by: CORGI No.:... Service Date: Signed:..... Comments: RECORD OF 8 th SERVICE Serviced by: CORGI No.:... Service Date: Signed:..... Comments:.... RECORD OF 9 th SERVICE Serviced by: CORGI No.:... Service Date: Signed:..... Comments: RECORD OF 10 th SERVICE Serviced by: CORGI No.:... Service Date: Signed:..... Comments:
19 19
20 Verine Limited 52 Broton Drive Trading Estate Halstead, Essex CO9 1HB Tel: (01787) Fax: (01787) Website: LOG/1006/II&UI THIS BOOKLET CONTAINS 20 PAGES 20
BALLADE BALANCED FLUE CONVECTOR FIRE
BALLADE BALANCED FLUE CONVECTOR FIRE MODEL No VBFC 16NG GAS COUNCIL NO. 32-234-14 THIS IS NOT A DO IT YOURSELF PRODUCT THIS APPLIANCE MUST BE INSTALLED BY A CORGI REGISTERED PERSON INSTALLATION, SERVICING
More informationULTRAFLUE ACCLAIM GAS COAL CONVECTOR
ULTRAFLUE ACCLAIM GAS COAL CONVECTOR MODEL NO'S. UPF16NV UPF18NG THIS IS NOT A 'DO-lT-YOURSELF' PRODUCT THIS APPLIANCE MUST BE INSTALLED BY A CORGI REGISTERED PERSON. INSTRUCTIONS FOR USE PLEASE LEAVE
More informationULTIMATE INSET LIVE FUEL EFFECT GAS FIRE MODEL 417 OWNER GUIDE
ULTIMATE INSET LIVE FUEL EFFECT GAS FIRE MODEL 417 OWNER GUIDE THE NATURAL GAS MODEL IS FOR G20 AT A SUPPLY PRESSURE OF 20mbar THE PROPANE GAS MODEL IS FOR G31 AT A SUPPLY PRESSURE OF 37mbar THESE APPLIANCES
More informationModel BR660VA Heat Engine
5112253/01 Model BR660VA Heat Engine POWER FLUE INSET GAS FIRE (GC No. 32-032-44) THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20). WHEN CONVERTED USING CONVERSION KIT NO. 0591149 THIS APPLIANCE IS FOR
More informationOWNER GUIDE. Model 739 OPEN DECORATIVE GAS FIRE. (GC No )
5113426/01 OWNER GUIDE Model 739 OPEN DECORATIVE GAS FIRE (GC No. 32-032-54) THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20). WHEN CONVERTED USING CONVERSION KIT NO. 0595211 THIS APPLIANCE IS FOR USE
More informationOWNER GUIDE. Anthem, Bolero, Camden, Minima, Victorian or Westminster fascia
5114465/01 OWNER GUIDE Model 741 INSET LIVE FUEL EFFECT GAS FIRE Fitted with Anthem, Bolero, Camden, Minima, Victorian or Westminster fascia (GC No. 32-032-56) THIS APPLIANCE IS FOR USE WITH NATURAL GAS
More informationOWNER GUIDE. Model 750. INSET LIVE FUEL EFFECT GAS FIRE Fitted with Harmony, Avignon or Style fascia. (GC No )
5112499/01 OWNER GUIDE Model 750 INSET LIVE FUEL EFFECT GAS FIRE Fitted with Harmony, Avignon or Style fascia (GC No. 32-032-58) THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20) WHEN CONVERTED USING CONVERSION
More informationINSET LIVE FUEL EFFECT GAS FIRE
600B741/02 OWNER S GUIDE MODEL BR650 VA (GC No. 32-032-39) INSET LIVE FUEL EFFECT GAS FIRE THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20) WHEN CONVERTED USING CONVERSION KIT NO.591149 THIS APPLIANCE
More informationINSTALLATION INSTRUCTIONS COMPACT GAS STOVE MODEL NUMBER 550
INSTALLATION INSTRUCTIONS COMPACT GAS STOVE MODEL NUMBER 550 Before installation ensure that the local distribution conditions (identification of the type of gas and pressure) and the adjustment of the
More informationModel 341 Black Beauty Slimline
600B690/13 OWNER GUIDE Model 341 Black Beauty Slimline LIVE FUEL EFFECT GAS FIRE (GC No. 32-032-30) We trust that this guide gives sufficient details to enable this appliance to be operated and maintained
More informationGB IE. VALOR BOLERO (MODEL BR626) Inset Decorative Fuel Effect Gas Fires. For
O W N E R G U I D E For VALOR BOLERO (MODEL BR626) Inset Decorative Fuel Effect Gas Fires GB IE This Owner Guide is intended to help you care for your Valor gas fire. Please read carefully before using
More informationDovre 250 Cast Iron Gas Stove
Dovre 50 Cast Iron Gas Stove NATURAL GAS AND LPG INSTALLATION, SERVICING AND USER INSTRUCTIONS THIS PRODUCT IS FOR USE ONLY IN GREAT BRITAIN AND IRELAND These instructions are to be left with the customer,
More information(manual control) (ezi-slide control) INSET COAL EFFECT GAS CONVECTOR FIRE V1/100/B INSTALLATION & USER INSTRUCTIONS
Model Number: V1/100/A V1/100/B (manual control) (ezi-slide control) INSET COAL EFFECT GAS CONVECTOR FIRE INSTALLATION & USER INSTRUCTIONS GB IE SUITABLE FOR USE ON NATURAL GAS (G20) AT 20mbar SUPPLY PRESSURE
More informationSonnet Plus Anthem Genesis Soraya
5108617/01 OWNER GUIDE Sonnet Plus Anthem Genesis Soraya Model 746 (GC No. 32-032-57) INSET LIVE FUEL EFFECT GAS FIRE THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20) WHEN CONVERTED USING CONVERSION KIT
More informationOWNER S GUIDE MODEL BR417 VA
600B702/06 OWNER S GUIDE MODEL BR417 VA (G.C.32-032-07) Inset Live Fuel Effect Gas Fire with Ultimate Front AS SUPPLIED, THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20) WHEN CONVERTED USING VALOR CONVERSION
More informationmorsø PANTHER GAS STOVE
morsø PANTHER GAS STOVE MODEL No. 553 OWNER S GUIDE This appliance meets the requirements of the European Gas Directive This guide is intended to help you care for your morsø gas stove. It gives sufficient
More informationSonnet Plus Anthem Genesis Soraya
5110524/01 OWNER GUIDE Sonnet Plus Anthem Genesis Soraya Model 747 (GC No. 32-032-51) INSET LIVE FUEL EFFECT GAS FIRE THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20) WHEN CONVERTED USING CONVERSION KIT
More informationTHIS PRODUCT IS APPROVED TO THE EUROPEAN GAS APPLIANCE DIRECTIVE
Solar Crown and Cast Inset Fires Installation Instructions THIS APPLIANCE MUST BE INSTALLED/SERVICED BY A COMPETENT PERSON IN ACCORDANCE WITH ALL THE REGULATIONS IN FORCE THIS PRODUCT IS APPROVED TO THE
More informationModel 741FS. Dream, Heritage or Opulent OWNER GUIDE. INSTALLER: Please leave this guide with the owner Baxi Heating U.K. Limited 2007.
5112500/02 Model 741FS Inset live fuel effect gas fire Incorporating the BAXI FIRES DIVISION CONTROL Fitted with one of the following fascia. Dream, Heritage or Opulent (GC No. 32-032-56) We trust that
More informationINSTALLATION, SERVICING AND USER INSTRUCTIONS
THE Ravena HE Radiant fan flue gas fire MODEL NUMBERS: NHPC/PPBMN & NHPC/PPBMP INSTALLATION, SERVICING AND USER INSTRUCTIONS 0120 0087 THIS APPLIANCE MEETS THE REQUIREMENTS OF THE EUROPEAN GAS DIRECTIVE
More informationKalahari DECORATIVE FUEL EFFECT GAS FIRE
Kalahari DECORATIVE FUEL EFFECT GAS FIRE User Instructions These instructions should be read by the user before operating the appliance and retained for future reference Model No. KRDC00MN & KRDC00SN are
More informationGrateGlow THE ALL NEW CAPITAL COLLECTION. G20 at 20mbar convertible to G31 at 37mbar. For use in GB and le. Users Instructions
GrateGlow A CARVER GROUP COMPANY --..--... THE GAS CONSUMERS' COUNCIL (GCC) IS AN INDEPENDENT ORGANISATION WHICH PROTECTS THE INTEREST OF GAS USERS. IF YOU NEED ADVICE, YOU WILL FIND THE TELEPHONE NUMBER
More informationLimours. Balanced Flue Room Heater MODEL NUMBER : KBFP00RN INSTALLATION, USER AND SERVICING INSTRUCTIONS THESE INSTRUCTIONS MUST REMAIN WITH THE USER
Limours Balanced Flue Room Heater MODEL NUMBER : KBFP00RN INSTALLATION, USER AND SERVICING INSTRUCTIONS THESE INSTRUCTIONS MUST REMAIN WITH THE USER This appliance is suitable for use on Natural Gas (G20)
More informationKALIDO 73. Convector Gas Fire MODEL NUMBERS: ACF526NG & ACF526P INSTALLATION, USER AND SERVICING INSTRUCTIONS
KALIDO 73 Convector Gas Fire MODEL NUMBERS: ACF526NG & ACF526P INSTALLATION, USER AND SERVICING INSTRUCTIONS THESE INSTRUCTIONS MUST REMAIN WITH THE USER 0120 THIS APPLIANCE MEETS THE REQUIREMENTS OF THE
More informationGB IE INSTALLATION & USER INSTRUCTIONS. Model Number: V1/300/B (ez-slide control) HIGH EFFICIENCY INSET COAL EFFECT GAS CONVECTOR FIRE
Model Number: V1/300/B (ez-slide control) HIGH EFFICIENCY INSET COAL EFFECT GAS CONVECTOR FIRE INSTALLATION & USER INSTRUCTIONS GB IE SUITABLE FOR USE ON NATURAL GAS (G20) AT 20mbar SUPPLY PRESSURE These
More informationEmberglow COAL EFFECT BALANCED FLUE GAS FIRE
Emberglow COAL EFFECT BALANCED FLUE GAS FIRE User Instructions These instructions should be read by the user before operating the appliance and retained for future reference Model No. FEBC00MN is only
More informationCRYSTAL FIRES. Inset Conventional Flue Fire. (BOSTON/MIAMI) Cf1 and MANHATTAN USER INSTALLATION AND SERVICING INSTRUCTIONS
CRYSTAL FIRES (BOSTON/MIAMI) Cf1 and MANHATTAN Inset Conventional Flue Fire USER INSTALLATION AND SERVICING INSTRUCTIONS FOR USE WITH NATURAL GAS G20 @ 20 mbar For use in GB and IE CE THESE INSTRUCTIONS
More informationClassic II NG. Decorative fuel effect appliances for use with Natural Gas. Installation, Servicing & User Instructions
Classic II NG Decorative fuel effect appliances for use with Natural Gas Installation, Servicing & User Instructions THESE INSTRUCTIONS TO BE LEFT WITH THE USER Canterbury Road, St. Nicholas-at-Wade, Nr.
More informationINSTALLATION, USERS AND SERVICING INSTRUCTIONS
INSTALLATION, USERS AND SERVICING INSTRUCTIONS SLIMLINE (FAN FLUE) HOTBOX Inset Decorative coal or pebble effect Gas Fire For use with Natural Gas (G20) @ 20mbar or Butane (G30) @ 28mbar or Propane (G31)
More informationOWNER GUIDE MODEL BR622 (GC ) INSET LIVE FUEL EFFECT GAS FIRE INCORPORATING. WITH ADORN, VISAGE, ELEGANT or ICON Front
'19 act 2000 6008624/01 May 2000 OWNER GUIDE MODEL BR622 (GC32-032 - 09) INSET LIVE FUEL EFFECT GAS FIRE INCORPORATING THE ~ VALOR FireSl~'deCONTROL (E WITH ADORN, VISAGE, ELEGANT or ICON Front THIS APPLIANCE
More informationMODEL 466 Radiant / Convector Gas Fire Black Beauty
O W N E R G U I D E MODEL 466 Radiant / Convector Gas Fire Black Beauty This Owner Guide is intended to help you care for your Valor gas fire. Please read carefully before using your gas fire and keep
More information5traxo INSTALLATION AND SERVICING INSTRUCTIONS MANDATORY REQUIREMENTS INSTALLATION
5traxo Division of Legge Fabheat Ltd Longfield Road, Sydenham, Leamington Spa CV31 1XB Tel. (0926) 882233 Fax (0926) 450846 Registered in England No. 500091 Universal INSTALLATION AND SERVICING INSTRUCTIONS
More informationDecorative Fuel Effect Appliances
Decorative Fuel Effect Appliances Technical Manual User and Installation Instructions for CUBB22US Available in Natural Gas. 1 Contents Section Pages 1 Unpacking 3 2 Installation Parameters 4 3 Installation
More informationEKOS 20 Fuel Effect Options: Coal Effect Pebble Effect Beachcomber Effect Shoreline Effect All available on NG & LPG
EKOS 20 Fuel Effect Options: Coal Effect Pebble Effect Beachcomber Effect Shoreline Effect All available on NG & LPG Control Options: Manual BM Control Upgradeable Manual Control Remote Control (Response-S)
More informationSquirrel - Gas Stoves
Squirrel - Gas Stoves Model No. 551 - With Open Flue INSTALLATION INSTRUCTIONS This appliance is for use with natural gas (G20) When converted using conversion kit no. 555111 this appliance is for use
More informationOWNER GUIDE. Sunfire II Radiant. Radiant / Convector Gas Fire. Model 347 (G. C. Number )
5110946/01 OWNER GUIDE Sunfire II Radiant Radiant / Convector Gas Fire Model 347 (G. C. Number 32-032-62) THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20) THIS APPLIANCE IS SUITABLE ONLY FOR INSTALLATION
More informationINSTALLATION & USERS INSTRUCTIONS. FOR USE WITH NATURAL GAS 20 mbar For use in GB and IE
1 valentine s buildings Bechers drive Aintree racecourse Business Park L9 5ay CF1 L GAS APPLIANCE INSET CONVENTIONAL FLUED GAS FIRE INSTALLATION & USERS INSTRUCTIONS FOR USE WITH NATURAL GAS G20 @ 20 mbar
More informationCLASSIC II QUATTRO DECORATIVE FUEL EFFECT APPLIANCES FOR USE WITH NATURAL GAS IIN INSTALLATION, SERVICING & USER INSTRUCTIONS
CLASSIC II QUATTRO DECORATIVE FUEL EFFECT APPLIANCES FOR USE WITH NATURAL GAS IIN INSTALLATION, SERVICING & USER INSTRUCTIONS THESE INSTRUCTIONS MUST BE LEFT WITH THE USER MANUFACTURED BY: MULTIGLOW FIRES
More informationKalahari RC & Camber RC
Kalahari RC & Camber RC DECORATIVE FUEL EFFECT GAS FIRE User Instructions These instructions should be read by the user before operating the appliance and retained for future reference Model No s KRDC**RN
More informationModel 956 OWNER GUIDE. This guide to be left with the owner INSET LIVE FUEL EFFECT GAS FIRE
5118756/03 Model 956 INSET LIVE FUEL EFFECT GAS FIRE Fitted with one of the following fascia. Anthem, Aura 2, Blenheim, Bolero, Camden, Capri, Coast, Contemporary, Debut, Flare, Form, Fusion, Homeflame
More informationModel 347 BLACK BEAUTY
110945/03 OWNER GUIDE Model 347 BLACK BEAUTY RADIANT / CONVECTOR GAS FIRE (G. C. No. 32-032-62) We trust that this guide gives sufficient details to enable this appliance to be operated and maintained
More informationPlus Model BR645 VA (G.C )
600B656/05 Plus Model BR645 VA (G.C. 32-032-34) As supplied, this appliance is for use with natural gas (G20) When converted using conversion kit no. 591149 this appliance is for use with propane gas (G31)
More informationOwner s Manual INCLUDES. PARAGON 2016 & PARAGON 2016 Hi IMPORTANT
Owner s Manual INCLUDES User, Maintenance, Service, and Installation Instructions PARAGON 2016 & PARAGON 2016 Hi Keep this booklet for service log and future reference IMPORTANT This appliance is guaranteed
More informationCOAL EFFECT BALANCED FLUE GAS FIRE
Raglan COAL EFFECT BALANCED FLUE GAS FIRE Installation and Maintenance Instructions Hand these instructions to the user Model No. KBFC**MN for use on Natural Gas (G20) at a supply pressure of 20 mbar in
More informationUSE & MAINTENANCE INSTRUCTIONS FOR NU-FLAME EVOLUTION PLUS GAS EFFECT FIRES (NATURAL GAS & LPG) FOR DECORATIVE PURPOSES ONLY
Unit 4, Kimpton Trade & Business Centre Minden Road, Sutton, Surrey SM3 9PF Tel: 020 8254 6802 IMPORTANT NOTE Simulated coals, simulated pebbles, simulated logs, simulated driftwood or crushed rock manufactured
More informationPREMOS 18 Models: Premos 18 Inset Premos 18 with Thermobox (LPG models prefixed with the letters LPG)
PREMOS 18 Models: Premos 18 Inset Premos 18 with Thermobox (LPG models prefixed with the letters LPG) Fuel Effect Options: Coal Effect Pebble Effect Beachcomber Effect Shoreline Effect All available on
More informationOWNER S GUIDE ETERNITY. MODEL 540C (GC No ) INSET BALANCED FLUE GAS FIRE
600B637/02 ETERNITY MODEL 540C (GC No. 32-032-19) INSET BALANCED FLUE GAS FIRE THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20) THIS APPLIANCE IS FOR USE IN THE UNITED KINGDOM (GB) AND THE REPUBLIC OF
More informationUSE & MAINTENANCE INSTRUCTIONS FOR CHESNEYS ALCHEMY EVOLUTION PLUS GAS FIRES (NATURAL GAS ONLY) FOR DECORATIVE PURPOSES ONLY
CHESNEYS ALCHEMY EVOLUTION PLUS GAS FIRE by IMPORTANT NOTE Simulated coals, or simulated logs, together with simulated black bark, are supplied with this appliance. These are all manufactured from refractory
More informationEMBERGLOW CLASSIC RADIANT CONVECTOR GAS FIRE. Installation and Maintenance Instructions
, EMBERGLOW CLASSIC RADIANT CONVECTOR GAS FIRE Installation and Maintenance Instructions Hand these instructions to the user Model No. FEMC00MN is for use on Natural Gas (G20) at a supply pressure of 20
More informationEKOS 16 Fuel Effect Options: Coal Effect Pebble Effect Beachcomber Effect Shoreline Effect All available on NG & LPG
EKOS 16 Fuel Effect Options: Coal Effect Pebble Effect Beachcomber Effect Shoreline Effect All available on NG & LPG Control Options: Manual BM Control Upgradeable Manual Control Remote Control (Response-S)
More informationNapoli BF COAL EFFECT BALANCED FLUE GAS FIRE
Napoli BF COAL EFFECT BALANCED FLUE GAS FIRE Installation, Maintenance & User Instructions Hand these instructions to the user Model No. ABFC**MN2 & ABFC**EN3 are for use on Natural Gas (G20) at a supply
More informationENIGMA HE Remote Control
ENIGMA HE Remote Control OWNERS MANUAL INCLUDES USER INSTRUCTIONS & INSTALLATION & MAINTENANCE INSTRUCTIONS Please read these instructions carefully before you start installing or using this appliance
More informationModel 939 Heat Engine
INSTALLER AND OWNER GUIDE 5117291/04 Model 939 Heat Engine OPEN DECORATIVE GAS FIRE (GC No. 32-032-54) For further advice please contact the retailer or company from where you purchased your fire INSTALLER:
More informationRiva 53/67. Inset Convector Fire - Balanced Flue. With Upgradeable Control Valve. Instructions for Use, Installation & Servicing
Riva 53/67 Inset Convector Fire - Balanced Flue With Upgradeable Control Valve Instructions for Use, Installation & Servicing For use in GB & IE (Great Britain & Republic of Ireland). IMPORTANT THE OUTER
More informationFull Depth Convector MC / SC
Full Depth Convector MC / SC COAL EFFECT GAS FIRE Installation and Maintenance Instructions Hand these instructions to the user Model No s MICC**MN & MICC**SN are for use on Natural Gas (G20) at a supply
More informationVFC Radiant & Convector
VFC Radiant & Convector Fire Range With Upgradeable Control Valve Instructions for Use, Installation and Servicing For use in GB, IE (Great Britain and Republic of Ireland) IMPORTANT THIS PRODUCT HAS A
More informationIntegra Convector Plus Manual
Integra Convector Plus Manual Inset Live Fuel Effect Gas Fire Installation and Users Instructions These instructions should be read by the installer before installation and then should be handed to the
More informationPARAGON FOCUS 18 HE REMOTE
PARAGON FOCUS 18 HE REMOTE OWNER MANUAL INCLUDES USER INSTRUCTION & INSTALLATION & MAINTENANCE INSTRUCTIONS Please read these instructions carefully before you start installing or using this appliance
More informationINSTALLER GUIDE COALFLAME & LIMOUSIN. MODEL BR627 (GC No ) INSET LIVE FUEL EFFECT GAS FIRE
600B607/05 INSTALLER GUIDE COALFLAME & LIMOUSIN MODEL BR627 (GC No. 32-032-22) INSET LIVE FUEL EFFECT GAS FIRE AS SUPPLIED, THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20) WHEN CONVERTED USING VALOR CONVERSION
More informationUSE & MAINTENANCE INSTRUCTIONS FOR NU-FLAME EVOLUTION PLUS GAS EFFECT FIRES (NATURAL GAS & LPG) FOR DECORATIVE PURPOSES ONLY
Unit 4, Kimpton Trade & Business Centre Minden Road, Sutton, Surrey SM3 9PF Tel: 020 8254 6802 IMPORTANT NOTE Simulated coals, simulated pebbles, simulated logs, simulated driftwood or crushed rock manufactured
More informationP 4 Series OWNER MANUAL INCLUDES USER INSTRUCTION & INSTALLATION & MAINTENANCE INSTRUCTIONS
P 4 Series OWNER MANUAL INCLUDES USER INSTRUCTION & INSTALLATION & MAINTENANCE INSTRUCTIONS Please read these instructions carefully before you start installing or using this appliance Keep this booklet
More informationENIGMA II SLIMLINE. Owner's Manual INCLUDES USER, INSTALLATION & MAINTENANCE INSTRUCTIONS
ENIGMA II SLIMLINE Owner's Manual INCLUDES USER, INSTALLATION & MAINTENANCE INSTRUCTIONS Please read these instructions carefully before you start using the appliance Keep this booklet handy for future
More informationImperial Electric Fires
Imperial Electric Fires GB IE MODELS: Flamescape II Curvascape II manual & remote. Installation and User Instructions PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN FOR FUTURE REFERENCE This electric
More informationMesina Fires GLASS FRONT VENTED Model No. M 70
Mesina Fires GLASS FRONT VENTED Model No. M 70 DECORATIVE COAL EFFECT NATURAL VENT GAS FIRE User Instructions These instructions should be read by the user before operating the appliance and retained for
More informationINSTALLER S GUIDE. MODEL 639 Open Decorative Gas Fire
3002369/03 INSTALLER S GUIDE MODEL 639 Open Decorative Gas Fire (G.C No. 32-032-47) THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20) WHEN CONVERTED USING CONVERSION KIT NO. 0591301 THIS APPLIANCE IS FOR
More informationINSTALLER AND OWNER GUIDE. For further advice please contact the retailer or company from where you purchased your stove
INSTALLER AND OWNER GUIDE 5138118/01 Vega 200 Gas Model 944 CAST-IRON GAS STOVE Fitted with a Ceramic Coal fuel effect. (GC No. 32-264-20) For further advice please contact the retailer or company from
More informationINSTALLER GUIDE. Firefox 8. Model 944. CAST-IRON GAS STOVE Fitted with a Ceramic Coal fuel effect. (GC No )
5130984/01 Firefox 8 Model 944 CAST-IRON GAS STOVE Fitted with a Ceramic Coal fuel effect. (GC No. 32-264-20) THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20). WHEN CONVERTED USING CONVERSION KIT NO. 0595261
More informationELITE. Models: 16 & 18 Fires c/w Thermobox. (LPG models prefixed with the letter L)
ME16T & ME18T ET16 & ET18 EV16 & EV18 ELITE Models: 16 & 18 Fires 16 & 18 Fires c/w Thermobox 16 & 18 Victorian Fires (LPG models prefixed with the letter L) Fuel Effect Options: Coal Effect NG and LPG
More informationFirefox 5. Model 910 CAST-IRON GAS STOVE. Fitted with a Ceramic Coal fuel effect. INSTALLER: Please leave this guide with the owner
DATA LIBRARY Catalog» Valor» Stove» Firefox» Firefox 5 (GC No. 3226424)» Installation Instructions» Firefox 5 Model 910 iss 01 INSTALLER GUIDE Firefox 5 Model 910 CAST-IRON GAS STOVE Fitted with a Ceramic
More informationINSTALLER AND OWNER GUIDE. Model 956 INSET MULTIFLUE GAS FIRE
5129357/02 INSTALLER AND OWNER GUIDE Model 956 INSET MULTIFLUE GAS FIRE (GC No. 32-811-47) We trust that this guide gives sufficient details to enable this appliance to be installed, maintained and operated
More informationBLACK KNIGHT 2 - Classic Collection
BLACK KNIGHT 2 - Classic Collection Installation & Servicing Instructions (GC No. 32 170 16) IMPORTANT - THIS FIRE DOES NOT NORMALLY REQUIRE ADDITIONAL VENTILATION INTO THE ROOM IN WHICH IT IS INSTALLED
More informationPARAGON SYMPHONY CF OWNER MANUAL INCLUDES USER INSTRUCTION & INSTALLATION & MAINTENANCE INSTRUCTIONS
PARAGON SYMPHONY CF OWNER MANUAL INCLUDES USER INSTRUCTION & INSTALLATION & MAINTENANCE INSTRUCTIONS Please read these instructions carefully before you start installing or using this appliance Keep this
More informationDovre 280. Conventional Flue Log Effect Stove. With Upgradeable Control Valve. Instructions for Use, Installation and Servicing
Dovre 280 Conventional Flue Log Effect Stove With Upgradeable Control Valve Instructions for Use, Installation and Servicing For use in GB, IE (Great Britain and Republic of Ireland) IMPORTANT THE OUTER
More informationINSTALLER GUIDE. Model 754. INSET LIVE FUEL EFFECT GAS FIRE Fitted with. Artura fascia. (GC No )
5113454/02 Model 754 INSET LIVE FUEL EFFECT GAS FIRE Fitted with Artura fascia (GC No. 32-032-59) THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20). THIS APPLIANCE IS SUITABLE ONLY FOR INSTALLATION IN THE
More informationSonnet Plus Anthem Genesis Soraya
5108617/01 INSTALLER GUIDE Sonnet Plus Anthem Genesis Soraya Model 746 (GC No. 32-032-57) INSET LIVE FUEL EFFECT GAS FIRE THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20) WHEN CONVERTED USING CONVERSION
More informationModel Apex Falcon, Titan & Zenit
Model Apex Falcon, Titan & Zenit Installation and User Instructions All instructions must be handed to user for safekeeping This is not a DIY product and must be installed by a Gas Safe registered installer
More informationOrchestra COAL EFFECT BALANCED FLUE GAS FIRE
Orchestra COAL EFFECT BALANCED FLUE GAS FIRE Installation and Maintenance Instructions Hand these instructions to the user Model No s FBFN76G & FBFN98G are for use on Natural Gas (G20) at a supply pressure
More informationBaxi Wentworth Classic Baxi Kingston 2 Classic
Baxi Wentworth Classic Baxi Kingston 2 Classic Please leave these instructions with the user Live Fuel Effect Inset Gas Fires Comp N o 244609 - Iss 4 6/00 Installation and Servicing Instructions Page 2
More informationPARAGON SIESTA PLUS. Remote Control
PARAGON SIESTA PLUS Remote Control OWNER'S MANUAL INCLUDES USER, INSTALLATION & MAINTENANCE INSTRUCTIONS Please read these instructions carefully before you start using the appliance Keep this booklet
More informationRivas Plus INSET LIVE FUEL-EFFECT GAS FIRES. Hand these instructions to the owner following installation, they must be retained for future reference.
Rivas Plus INSET LIVE FUEL-EFFECT GAS FIRES Installation, Maintenance & User Instructions. Hand these instructions to the owner following installation, they must be retained for future reference. Model
More informationC&J DGT5000 Suite Shelf or Slab Burner. Owner's Book
C&J DGT5000 Suite Shelf or Slab Burner Owner's Book (THIS APPLIANCE IS FITTED WITH ALKALINE BATTERIES) INCLUDES USER, INSTALLATION & MAINTENANCE INSTRUCTIONS Please read these instructions carefully before
More informationRiva Nemos. Balanced Flue Convector Fire. Instructions for Use, Installation and Servicing. For use in GB, IE (Great Britain and Eire) IMPORTANT
Riva Nemos Balanced Flue Convector Fire Instructions for Use, Installation and Servicing For use in GB, IE (Great Britain and Eire) IMPORTANT THE OUTER CASING, FRONT AND GLASS PANEL BECOME EXTREMELY HOT
More informationHunter Hawk Gas Stove User Instructions
Hunter Hawk Gas Stove User Instructions Please leave this instruction booklet with the user after the installation is complete. Leave the system ready for operation and instruct the user in the correct
More informationVFC Convector Pebble Effect Fires With upgradeable control valve
VFC Convector Pebble Effect Fires With upgradeable control valve Instructions for Use, Installation and Servicing For use in GB, IE (Great Britain and Eire) This appliance has been certified for use in
More informationPARAGON ONE REMOTE Owner's Book
PARAGON ONE REMOTE Owner's Book (THIS APPLIANCE IS FITTED WITH ALKALINE BATTERIES) INCLUDES USER, INSTALLATION & MAINTENANCE INSTRUCTIONS Please read these instructions carefully before you start using
More informationRADIANT / CONVECTOR GAS FIRE MODEL 426 (GC ) INSTALLATION & SERVICING INSTRUCTIONS INSTALLER: Please leave these instructions with the owner
THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20) AT A SUPPLY PRESSURE OF 20mbar (8in w.g.) THIS APPLIANCE IS FOR USE IN THE UNITED KINGDOM (GB) AND THE REPUBLIC OF IRELAND (IE) RADIANT / CONVECTOR GAS
More informationINSTALLER GUIDE. Anthem, Bolero, Camden, Minima, Victorian or Westminster fascia
5114465/01 INSTALLER GUIDE Model 741 INSET LIVE FUEL EFFECT GAS FIRE Fitted with Anthem, Bolero, Camden, Minima, Victorian or Westminster fascia (GC No. 32-032-56) THIS APPLIANCE IS FOR USE WITH NATURAL
More informationPARAGON FOCUS HE MULTI - FLUE SLIDE CONTROL
PARAGON FOCUS HE MULTI - FLUE SLIDE CONTROL OWNER MANUAL INCLUDES USER INSTRUCTION & INSTALLATION & MAINTENANCE INSTRUCTIONS Please read these instructions carefully before you start installing or using
More informationHuntingdon 20/30/40. Conventional Flue Log Effect Stove. With Upgradeable Control Valve. Instructions for Use, Installation and Servicing
Huntingdon 20/30/40 Conventional Flue Log Effect Stove With Upgradeable Control Valve Instructions for Use, Installation and Servicing For use in GB, IE (Great Britain and Republic of Ireland) IMPORTANT
More informationSmall Marlborough, Stockton & Steel Manhattan
Small Marlborough, Stockton & Steel Manhattan Balanced Flue with Upgradeable Control Valve Small Marlborough Small Stockton Small Steel Manhattan Instructions for Use, Installation & Servicing For use
More informationPARAGON 2000 Xtra SLIDE CONTROL Owner's Book
PARAGON 2000 Xtra SLIDE CONTROL Owner's Book INCLUDES USER, INSTALLATION & MAINTENANCE INSTRUCTIONS Please read these instructions carefully before you start using the appliance Keep this booklet handy
More informationClarendon & Ashdon. Conventional Flue Log Effect Stove Range. With Upgradeable Control Valve. Instructions for Use, Installation & Servicing
Clarendon & Ashdon Conventional Flue Log Effect Stove Range With Upgradeable Control Valve Instructions for Use, Installation & Servicing For use in GB & IE (Great Britain & Republic of Ireland). IMPORTANT
More informationBroadway, Valor Landscape 2 Gas or Vermont fascia
5122667/01 INSTALLER AND OWNER GUIDE Model 752 INSET LIVE FUEL EFFECT GAS FIRE Fitted with a Broadway, Valor Landscape 2 Gas or Vermont fascia (GC No. 32-032-74) We trust that this guide gives sufficient
More informationRiva2 530/670. Inset Convector Fire - Conventional Flue. with Thermostatic Remote Control. Instructions for Use, Installation & Servicing
Riva2 530/670 Inset Convector Fire - Conventional Flue with Thermostatic Remote Control IMPORTANT: For easy to follow, step by step video instructions on how to operate and maintain your Gazco remote system
More informationF67 RIVA, F67 RIVA PEDESTAL, F67 RIVA BENCH Conventional & Balanced Flue Convector Fire
F67 RIVA, F67 RIVA PEDESTAL, F67 RIVA BENCH Conventional & Balanced Flue Convector Fire Instructions for Use, Installation and Servicing For use in GB, IE (Great Britain and Eire) IMPORTANT THE OUTER CASING,
More informationENIGMA II SLIDE CONTROL Owner's Book
ENIGMA II SLIDE CONTROL Owner's Book INCLUDES USER, INSTALLATION & MAINTENANCE INSTRUCTIONS Please read these instructions carefully before you start using the appliance Keep this booklet handy for future
More informationClarendon and Ashdon Log Effect Stove Range
Clarendon and Ashdon Log Effect Stove Range Conventional Flue With upgradeable control valve Instructions for Use, Installation and Servicing For use in GB, IE (Great Britain and Eire) This appliance has
More informationMarlborough & Stockton
Marlborough & Stockton Conventional Flue Coal Effect Stove With Upgradeable Control Valve Instructions for Use, Installation & Servicing For use in GB & IE (Great Britain & Republic of Ireland). IMPORTANT
More informationINSTALLER AND OWNER GUIDE Airflame Convector
5134830/06 INSTALLER AND OWNER GUIDE Airflame Convector Inset live fuel effect gas fire Fitted with one of the following trim. Blakely, Bloomsbury, Full Trim & Inlay Trim Frets: Alton, Bauhaus, Blenheim,
More informationConventional Flue. Instructions for Use, Installation and Servicing. For use in GB, IE (Great Britain and Republic of Ireland) IMPORTANT
Logic HE Range Conventional Flue Instructions for Use, Installation and Servicing For use in GB, IE (Great Britain and Republic of Ireland) IMPORTANT THE OUTER CASING, FRONT AND GLASS PANEL BECOME EXTREMELY
More information