1 Operating and Installation Instructions Diaphragm Vacuum Pumps Type ranges: N 836 APE N 836 AP.40 E N APE N AP.40 E Fig. 1: N AP.40 E You have selected a high-quality KNF product; the following tips will help you operate it safely, and reliably over a long period of time. Carefully study the operating and installation instructions before using the pumps and observe at all times the relevant instructions to avoid dangerous situations. The manual was produced for the serial pumps stated above. With customer-specified projects (pump types starting with PJ or PM ) there could be differences in detail. For customer-specified projects please therefore take into account any agreed technical specifications, as well as these instructions. List of Contents KNF Neuberger GmbH Alter Weg 3 D Freiburg Germany Phone +49/(0)7664 / Fax +49/(0)7664 / info@knf.de Page Description, Operating Conditions... 2 Safety... 4 Installation... 6 Operation... 7 Servicing... 9 Cleaning Trouble Shooting Spare parts Tables Returns Health and safety clearance and decontamination form KNF /14 Translation of original Operating and Installation Instructions, english

2 Description, Operating Conditions Diaphragm Vacuum Pumps N Description, Operating Conditions Pumps in the N 836 range have been specially designed to meet the requirements of vapour sterilisation and vacuum drying. The following versions are available: Basic models: pump types N 836 APE and N APE. Versions with integral venting valve: pump types N 836 AP.40 E and N AP.40 E. The pump head is aerated at regular intervals initiated by the control system of the autoclave or drying cabinet, but, at the same time, vacuum is maintained in the sterilisation chamber. In this way, condensate that has collected in the pump head is blown out. Versions with integral venting valve and cooling system (water cooling): on a project basis. Water cooling of the pump heads enables the evacuation time to be even shorter. KNF pumps in the N 836 range transfer and evacuate 100% oilfree. In operation they are gas-tight, and maintenance-free Electrical Equipment See the type-plate for full electrical data of the motor. For all pumps with venting valves: the venting valve operates on a 24V DC supply (without power closed). The protection class of standard versions is IP00. The motors used are fitted as standard with a thermal switch to protect against overloading. 2 Translation of original Operating and Installation Instructions, English, KNF /14

3 Diaphragm Vacuum Pumps N 836 Description, Operating Conditions 1.2. Operating Conditions Handling air, gases, and vapours at temperatures between + 5 C C. For maximum permissible operating pressure, ultimate vacuum, and flow capacity see section 10. The pumps must not be used in areas where there is a danger of explosion. Before pumping a medium, the compatibility of materials of pump head, diaphragm and valves with the medium must be checked (for pump materials: see section 10). Versions with integral venting valve: The pumps must not be used if the entry of air into the pump during venting could result in the creation of reactive, explosive or otherwise hazardous mixtures. KNF pumps in the N 836 range must not be used for liquids. You will find suitable liquid pumps in our Product Program. If your potential application lies outside the above limits discuss it with our technical adviser (see last page for contact telephone number) Ambient Conditions When the pump is operating the following ambient conditions must be maintained: Ambient temperature during operation: between + 5 C + 40 C. The pump must be protected from the effects of dust and water. The pump must not be used in areas where there is a danger of explosion. During operation an adequate supply of air for cooling must be provided Pump materials See section 9. Translation of original Operating Instructions, English, KNF /14 3

4 Safety Diaphragm Vacuum Pumps N 836 EC Directives / Standards 2. Safety The standard pumps have Protection Class 00, and so offer no protection against contact or foreign bodies. It is therefore essential to protect personnel against contact with live parts (e.g. electrical connections, motor windings), and moving parts (e.g. fan). Protection against the ingress of particulate matter must also be provided. The pump is not protected against water. In this case too, as far as is relevant, measures to protect the pump must be taken before putting it into service. Note that the pumps may only be used for their intended purpose. The pumps must not be used in areas where there is a danger of explosion. Versions with integral venting valve: The pumps must not be used if the entry of air into the pump during venting could result in the creation of reactive, explosive or otherwise hazardous mixtures. Prior to any use of the pump ensure that the creation of reactive, explosive or otherwise hazardous mixtures during the supply of air is prevented. The pumps are not suitable for aggressive media. Components connected to the pump must be designed to withstand the pneumatic performance of the pump. Take care that safety regulations are observed when connecting the pump to the electricity supply. When the operation of the pump is interrupted by the thermal switch, the pump will re-start automatically after cooling down. Take all care necessary to prevent this leading to a dangerous situation. Specific safety instructions for the media being handled must be observed. Use only original KNF spare parts. For the purposes of the Machinery Directive 2006/42/EC, pumps are partly completed machinery, and are therefore to be regarded as not ready for use. Partly completed machinery may not be commissioned until such time as it has been determined that the machine in which the partly completed machinery is to be assembled is in conformity with the provisions of the Machinery Directive 2006/42/EC. The following essential requirements of Annex I of Directive 2006/42/EC (general principles) are applied and observed: General Principles No. 1 No / / / / / / / / / / / / As these partly completed machinery are OEM-models the power supplies and the equipment for disconnecting and switching-off the partly completed machinery respectively have to be considered 4 Translation of original Operating and Installation Instructions, English, KNF /14

5 Diaphragm Vacuum Pumps N 836 Safety when mounting as well as over-current and overload protective gear. In addition a protection against mechanical parts in motion and hot parts, if existing, has to be provided when mounting. The pumps conform to the Directive 2011/65/EU (RoHS2). The pumps conform to the EC Directive 2004/108/EC concerning Electromagnetic Compatibility. The following harmonized standards have been used: DIN EN /2 DIN EN /3 DIN EN Translation of original Operating Instructions, English, KNF /14 5

6 Installation Diaphragm Vacuum Pumps N 836 Mechanical Electrical Pneumatic Water cooling 3. Installation The pumps are OEM models intended for installation in equipment. When installing them make certain that accident prevention regulations, and safety instructions, including those for subsequent operation are observed. The safety instructions in section 2 must be observed. The dimensions of the mountings are given in Data Sheet E 180. Install the pump so that the fan can draw in sufficient cooling air. Fit the pump at the highest point in the system, so that condensate cannot collect in the head of the pump - that prolongs working life. When making the electrical installation the safety regulations must be observed. In particular make sure that the electricity supply is isolated before trying to connect the pump. Compare the supply data with the data on the motor-plate. The voltage must not vary by more than +10% and -10% from that shown on the type-plate. The motor must be connected to earth (ground) wire. In the electrical installation, arrangements (complying with EN ) must be made for disconnecting the pump motor from the electrical supply. The pump must be installed so that contact with live parts is impossible. We recommend that a fuse is installed in the motor supply circuit; the operating current is given in Data Sheet E 180. Pump types N 836 AP.40 E and N AP.40 E: the venting valve must be electrically connected to the control system of the autoclave or drying cabinet (for connection values, see Section 1.1). These units then control operation of the valve. Remove the protection plugs from the port threads. Connect the suction and pressure lines. Arrange the suction and pressure lines so that condensate cannot run into the pump. Project pumps with water cooling: the water supply and drain lines must be connected to the pump heads. KNF recommends that the direction of flow of the cooling water should be the same as the gas flow through the heads (see markings on the pump heads). 6 Translation of original Operating and Installation Instructions, English, KNF /14

7 Diaphragm Vacuum Pumps N 836 Operation 4. Operation Specific safety instructions for the media being handled must be observed. The pumps must not be used in areas where there is a danger of explosion. Versions with integral venting valve: The pumps must not be used if the entry of air into the pump during venting could result in the creation of reactive, explosive or otherwise hazardous mixtures. Prior to any use of the pump ensure that the creation of reactive, explosive or otherwise hazardous mixtures during the supply of air is prevented. If combustible media are used: Hazard of fires and explosions due to excessively high media temperature. Be aware that the pumps are not designed to be explosion-proof. Make sure the temperature of the medium is always sufficiently below the ignition temperature of the medium, to avoid ignition or explosion. This also applies for unusual operational situations. Note that the temperature of the medium increases when the pump compresses the medium. Hence, make sure the temperature of the medium is sufficiently below the ignition temperature of the medium, even when it is compressed to the maximum permissible operating pressure of the pump. The maximum permissible operating pressure of the pump is stated in the technical specifications (section 10). If necessary, consider any external sources of energy, such as radiation, that may add heat to the medium. In case of doubt, consult the KNF customer service. Before pumping a medium, the compatibility of materials of pump head, diaphragm and valves with the medium must be checked (for pump materials: see section 10). The pump must not start against pressure or vacuum. When it is switched on the pressure in the suction and pressure lines must be atmospheric. This must be so even when the pump restarts after the power has been cut off for a short period. The maximum permissible operating pressure (see section 10) must not be exceeded. To prevent the maximum permissible operating pressure being exceeded, restriction or control of the air or gas flow should only be carried out in the suction line. Translation of original Operating Instructions, English, KNF /14 7

8 Operation Diaphragm Vacuum Pumps N 836 If restriction or control of the air or gas flow is made on the pressure side ensure that the maximum permissible operating pressure is not exceeded. When the pump is at a standstill the inlet and exhaust must be at normal atmospheric pressure. When the operation of the pump is interrupted by the thermal switch, the pump will re-start automatically after cooling down. Take all care necessary to prevent this leading to a dangerous situation. Diaphragm and valve plates are the only parts subject to wear. Wear is usually indicated by a drastic reduction in the pneumatic performance. When replacing parts proceed as described in section 5. Ambient conditions: see section 1.3. KNF recommends that, at the end of an evacuation operation, the pump should be allowed to run for a few minutes to remove condensate from the pump heads. 8 Translation of original Operating and Installation Instructions, English, KNF /14

9 Diaphragm Vacuum Pumps N 836 Servicing 5. Servicing Diaphragm and valve plates are the only parts of the pump subject to wear. They are simple to change. Always change diaphragms, valve plates and sealing rings at the same time. In the case of models with two heads service both heads at the same time One-headed pumps Before working on the pump isolate the power supply securely, then check that the lines are not live. Parts required Spare part Quantity Structured diaphragm 1 Valve plates 2 Tab. 1: Spare parts *According to Spare parts list, section 8 Tools required Type range Tools/Material All Phillips screwdriver No. 2 Screwdriver blade width 3.0 mm (or similar size) Felt-tip marker Tab. 2: Tools Change the structured diaphragm and valve plates in the following sequence: a) Preparatory steps b) Removing pump head c) Changing structured diaphragm d) Changing valve plates e) Refitting pump head f) Final steps Proceed as follows (see figs. 2 and 3): Translation of original Operating Instructions, English, KNF /14 9

10 Servicing Diaphragm Vacuum Pumps N 836 Fig. 3: Pump Specification Pos Description Fig. 2: Cross section of pump head 1 Recessed head screw 2 Recessed head screw 3 Ribbed plate 4 Intermediate plate 5 Adapter 6 Intermediate flange 7 Structured diaphragm 8 Diaphragm spacer 9 Disc 10 Spacer ring 11 Foam-plastic insert 1 12 Foam plastic insert 2 13 Valve plate 19 Venting valve* 20 Cover of motor fan 21 Slot of cover of motor fan * only pump types N 836 AP.40 E, N AP.40 E, a) Preparatory steps 1. Remove fan cover (20) from pump housing; to do this insert a screwdriver into the slots (21) and open the snaps. b) Removing pump head 1. Mark the position of ribbed plate (3), intermediate plate (4), and adapter (5) relative to each other by a drawing line with a felttip marker. This is to ensure that the parts will be reassembled in correct position at a later stage. 2. Undo the 4 screws (1) in the ribbed plate (3). Do not undo the screws (2)! 3. Carefully remove ribbed plate (3) with intermediate plate (4). 10 Translation of original Operating and Installation Instructions, English, KNF /14

11 Diaphragm Vacuum Pumps N 836 Servicing c) Changing structured diaphragm 1. Turn the fan to bring the structured diaphragm (7) to its highest position. In this position there is good access to the structured diaphragm. 2. Carefully lift the edge of the structured diaphragm (7) and, gripping it on opposite sides, unscrew it anti-clockwise using both hands. 3. Replace all diaphragm spacer(s) (8) onto the screw thread of the new structured diaphragm. 4. Check that all parts are free from dirt and clean them if necessary (see section 6. Cleaning). 5. Screw the new structured diaphragm, complete with diaphragm spacers (8) into the connecting rod (clockwise) and tighten it by hand. Take care that the disc (9) is seated on the spacer ring (10), and that the foam-plastic inserts (11) and (12) (different sizes) are in position. d) Changing valve plates 1. Undo the two screws (2) in the ribbed plate (3). 2. Separate ribbed plate (3) from intermediate plate (4). 3. Remove valve plates (13) from intermediate plate (4). 4. Check that the valve seats in the ribbed plate and intermediate plate are clean. If damages, distortion, or corrosion are evident on these parts they should be replaced. 5. Lay the new valve plates (13) in the recesses in the intermediate plate (4). The valve plates for suction and pressure sides are identical, as are upper and lower sides of the plates. A tab ensures correct location of the valve plates. e) Refit the pump head 1. Place the intermediate plate (4) with valve plates (13) on the adapter (5) in the position indicated by the marking. The marking ensures that the orientation of the intermediate plate is correct. 2. Place the ribbed plate (3) on the intermediate plate (4) in the position indicated by the marking. 3. Screw in the 2 screws (2) (with disc springs) until the screw heads are just seated - that is to say, until the first resistance is felt, do not tighten them fully. 4. Gently tighten the screws (1), evenly and diagonally. 5. Turn the fan to check that the pump rotates freely. 6. Now tighten screws (1) diagonally (hand-tight). 7. Tighten the screws (2) another half-turn each. Translation of original Operating Instructions, English, KNF /14 11

12 Servicing Diaphragm Vacuum Pumps N 836 f) Final steps 1. Refit cover of motor fan (20). If you have any questions about servicing call our technical adviser (see last page for contact telephone number). 12 Translation of original Operating and Installation Instructions, English, KNF /14

13 Diaphragm Vacuum Pumps N 836 Servicing 5.2. Two-headed pumps Before working on the pump isolate the power supply securely, then check that the lines are not live. Parts required Spare part Quantity Structured diaphragms 2 Valve plates 4 Tab. 3: Spare parts *According to Spare parts list, section 8 Tools required Type range Tools/Material All Phillips screwdriver No. 2 Screwdriver blade width 3.0 mm (or similar size) Felt-tip marker Tab. 4: Tools Change the structured diaphragm and valve plates in the following sequence: a) Preparatory steps b) Removing pump head c) Changing structured diaphragm d) Changing valve plates e) Refitting pump head f) Final steps Proceed as follows (see figs. 2 and 3): a) Preparatory steps 1. Remove fan cover (20) from pump housing; to do this insert a screwdriver into the slots (21) and open the snaps. b) Removing pump heads 1. At both pump heads: Mark the position of ribbed plate (3), intermediate plate (4), and adapter (5) relative to each other by a drawing line with a felt-tip marker. This is to ensure that the parts will be reassembled in correct position at a later stage. 2. At both pump heads: Undo the 4 screws (1) in the ribbed plate (3). Do not undo the screws (2)! 3. Carefully lift off both ribbed plates (3) with intermediate plates (4). Translation of original Operating Instructions, English, KNF /14 13

14 Servicing Diaphragm Vacuum Pumps N 836 c) Changing structured diaphragms 1. Turn the fan to bring one structured diaphragm (7) to its highest position. In this position there is good access to the structured diaphragm. 2. Carefully lift the edge of the structured diaphragm (7) and, gripping it on opposite sides, unscrew it anti-clockwise using both hands. 3. Replace all diaphragm spacer(s) (8) onto the screw thread of the new structured diaphragm. 4. Check that all parts are free from dirt and clean them if necessary (see section 6. Cleaning). 5. Screw the new structured diaphragm, complete with diaphragm spacers (8) into the connecting rod (clockwise) and tighten it by hand. Take care that the disc (9) is seated on the spacer ring (10), and that the foam-plastic inserts (11) and (12) (different sizes) are in position. 6. Carry out steps 1 to 5 for the second pump head. d) Changing valve plates 1. For one pump head: Undo the two screws (2) in the ribbed plate (3). 2. Separate ribbed plate (3) from intermediate plate (4). 3. Remove valve plates (13) from intermediate plate (4). 4. Check that the valve seats in the ribbed plate and intermediate plate are clean. If damages, distortion, or corrosion are evident on these parts they should be replaced. 5. Lay the new valve plates (13) in the recesses in the intermediate plate (4). The valve plates for suction and pressure sides are identical, as are upper and lower sides of the plates. A tab ensures correct location of the valve plates (see figure 3). 6. Carry out steps 1 to 5 for the second pump head. e) Refit the pump heads 1. At both heads: Place the intermediate plate (4) with valve plates (13) on the adapter (5) in the position indicated by the marking. The marking ensures that the orientation of the intermediate plate is correct. 2. Place the both ribbed plates (3) on the intermediate plates (4) in the position indicated by the markings. 3. At both pump heads: Screw in the 2 screws (2) (with disc springs) until the screw heads are just seated - that is to say, until the first resistance is felt, do not tighten them fully. 4. Gently tighten on both pump heads the screws (1), evenly and diagonally. 14 Translation of original Operating and Installation Instructions, English, KNF /14

15 Diaphragm Vacuum Pumps N 836 Servicing 5. Turn the fan to check that the pump rotates freely. 6. Now tighten on both pump heads screws (1) diagonally (handtight). 7. At both pump heads: Tighten the screws (2) another half-turn each. f) Final steps 1. Refit cover of motor fan (20). If you have any questions about servicing call our technical adviser (see last page for contact telephone number). Translation of original Operating Instructions, English, KNF /14 15

16 Cleaning Diaphragm Vacuum Pumps N Cleaning When changing valve plates and diaphragm, inspect all parts for dirt before assembling the pump head, and clean them if necessary. If a compressed air line is available, blow the parts out with it. 16 Translation of original Operating and Installation Instructions, English, KNF /14

17 Diaphragm Vacuum Pumps N 836 Trouble Shooting 7. Trouble Shooting Before working on the pump isolate the power supply securely, then check that the lines are not live. The following tips for fault-finding are best employed in the sequence shown. Pump produces no flow Connections or lines are blocked An external valve is closed, or a filter blocked. Liquid (condensate) has collected in the pump head. Let the pump run for a few minutes pumping air (if necessary for safety reasons: pumping an inert gas.) Install the pump at the highest point in the system. Diaphragms or valve plates are worn. Section 5 Servicing. Flow, pressure, or vacuum too low Compare the actual performance with the figures in section 10 or the data sheet. Liquid (condensate) has collected in the pump head. Let the pump run for a few minutes pumping air (if necessary for safety reasons: pumping an inert gas). Install the pump at the highest point in the system. There is pressure on the pressure side, and at the same time vacuum, or a pressure above atmospheric, on the suction side. The pump is not designed for this condition. The cross-section of pneumatic lines, or connected components is too small, or they are restricted. To measure the performance, disconnect the pump from the system (small diameter tubing or a valve can significantly affect performance). There is a leak at a connector, in a line, or in the pump head. For pump types N 836 AP.40 E and N AP40. E as well as for pump types with water cooling (project pumps): The seal in the ventilating valve is defective. Change seal (see section 8 Spare Parts for correct seal). Translation of original Operating Instructions, English, KNF /14 17

18 Trouble Shooting Diaphragm Vacuum Pumps N 836 Diaphragm or valve plate are worn, or dirt is in the head: Section 5 Servicing. If the pump does not operate properly and you cannot find any of the above faults, send it to the KNF Service Department. In order for KNF to repair the pump, the customer must provide a statement on the media which were pumped and on pump cleaning. Please fill out the corresponding KNF form, and submit it together with the pump. A sample statement for copying can be found in section 11 of these operating instructions. 18 Translation of original Operating and Installation Instructions, English, KNF /14

19 Diaphragm Vacuum Pumps N 836 Spare parts 8. Spare parts Pos. Bezeichnung Order-No. No.* 7 Structured diaphragm Valve plate Seal for venting valve (EPDM) Tab. 5: Spare parts *according to figs. 3 and 4 9. Tables Pump type Max. permissible operating pressure (bar g) Ultimate vacuum (mbar abs.) N 836 APE N APE N 836 AP.40 E N AP 40 E Delivery rate* (l/min) at atm. pressure Tab. 6: Pneumatic Data *Litre at STP Technical data apply to all pump models: Material Pump head Alumium alloy anodized and coated; PPS Tab. 7: Pump materials Structured Valve plates Venting valve* diaphragm EPDM EPDM Stainless steel, EPDM ** not pump types N 836 APE and N APE Translation of original Operating Instructions, English, KNF /14 19

20 Returns Diaphragm Vacuum Pumps N Returns Pumps and systems used in laboratories and process-based industries are exposed to a wide variety of conditions. This means that the components contacting pumped media could become contaminated by toxic, radioactive, or otherwise hazardous substances. For this reason, customers who send any pumps or systems back to KNF must submit a Health and safety clearance and decontamination form in order to avoid a hazardous situation for KNF employees. This Health and safety clearance and decontamination form provides the following information, among other things: physiological safety whether medium-contacting parts have been cleaned whether the equipment has been decontaminated media that have been pumped or used and must declare physiological safety. To ensure worker safety, work may not be started on pumps or systems without a signed Health and safety clearance and decontamination form. For optimal processing of a return, a copy of this declaration should be sent in advance via , regular mail, or fax to KNF Customer Service (refer to final page for address). In order to avoid endangering employees who open the shipment's packaging, despite any residual hazards, the original version of the Health and safety clearance and decontamination form must accompany the delivery receipt on the outside of the packing. The template for the Health and safety clearance and decontamination form is included with these Operating Instructions and may also be downloaded from the KNF website. The customer must specify the device type(s) and serial number(s) in the Health and safety clearance and decontamination form in order to provide for the unambiguous assignment of the Declaration to the device that is sent to KNF. In addition to the customer's declaration of physiological safety, information about operating conditions and the customer's application are also of importance to ensure that the return shipment is handled appropriately. Therefore, the Health and safety clearance and decontamination form requests this information as well. 20 Translation of original Operating and Installation Instructions, English, KNF /14

21 Diaphragm Vacuum Pumps N 836 Health and safety clearance and decontamination form 11. Health and safety clearance and decontamination form Translation of original Operating and Installation Instructions, english, KNF /14 21

22 Benelux Netherlands KNF Verder B.V. Utrechtseweg 4a NL-3451 GG Vleuten Tel (0) Fax 0031 (0) Benelux Belgium, Luxembourg KNF Verder N.V. Kontichsesteenweg 17 B-2630 Aartselaar Tel (0) Fax 0032 (0) China KNF Neuberger Trading (Shanghai) Co., Ltd No. 36 Lane 1000 Zhang Heng Road Shanghai , P.R. China Tel (0) Fax 0086 (0) Germany KNF Neuberger GmbH Alter Weg 3 D Freiburg Tel (0) Fax 0049 (0) info@knf.de France, Morocco, Algeria KNF Neuberger 4, Bld. d Alsace Z.I. F Village-Neuf Tel (0) Fax 0033 (0) info@knf.fr KNF worldwide Great Britain KNF Neuberger U.K. Ltd. Avenue 2 Station Lane Industrial Estate Witney Oxon OX28 4FA Tel (0) Fax 0044 (0) info@knf.co.uk India KNF Pumps + Systems (India) Pvt. Ltd. RAJIV GANDHI INFOTECH PARK Phase 1 Ganga Estate, Survey No. 152/2/2 Above AXIS BANK Hinjewadi Pune Tel (0) (0) Fax 0091 (0) info@knfpumps.in Italy KNF ITALIA S.r.l. Via Flumendosa, 10 I Milano Tel Fax info@knf.it Japan KNF Japan Co.Ltd. Across Shinkawa Bldg. Annex 3F Shinkawa, Chuo-ku, Tokyo, Japan Tel (0) Fax 0081 (0) info@knf.co.jp Korea KNF Neuberger Ltd. Woosan Bldg.RM#202, 336-4, Hwikyung-Dong Dongdaemun-Ku., , Seoul Tel (0) /6 Fax 0082 (0) knf@knfkorea.com KNF product centres Sweden, Denmark, Finland, Norway KNF Neuberger AB Mejerivägen 4, P.O. Box SE Stockholm Tel (0) Fax 0046 (0) info@knf.se Switzerland Sales KNF Neuberger AG Stockenstrasse 6 CH-8362 Balterswil Tel (0) Fax 0041 (0) knf@knf.ch Taiwan KNF Neuberger Ltd. 9-2 FL., No., 24, Lane 123, Section 6, Ming Chuan East Road Taipei City, Taiwan Tel Fax knftwn@knftwn.com.tw USA, Canada, South America KNF Neuberger, Inc. Two Black Forest Road Trenton, New Jersey Tel. 001 (609) Fax 001 (609) knfusa@knf.com South America Direct Phone: gb@knf.com Product centre for gas pumps: Germany KNF Neuberger GmbH Alter Weg 3 D Freiburg Phone 0049(0) Fax 0049(0) info@knf.de Product centre for fluid pumps: Switzerland KNF FLODOS AG Wassermatte 2 CH-6210 Sursee Phone 0041(0) Fax 0041(0) info@knf-flodos.ch Product centre for micro pumps: Switzerland KNF Micro AG Zelglimatte 1b CH-6260 Reiden Tel. 0041(0) Fax 0041(0) info@knf-micro.ch

Multi-User Vacuum Systems for up to ten Users LABOBASE

Multi-User Vacuum Systems for up to ten Users LABOBASE Data Sheet Labobase LABOBASE Chemically-resistant Vacuum Systems for Multi-User Technical features: Maintenance-free Silent More room on the laboratory bench Fully-automatic vacuum generation for several

More information

DIAPHRAGM VACUUM PUMPS FOR AUTOCLAVES

DIAPHRAGM VACUUM PUMPS FOR AUTOCLAVES DIAPHRAGM VACUUM PUMPS FOR AUTOCLAVES DATA SHEET E012 N 816.3 KPE N 816.6 KPE Concept Diaphragm Vacuum Pumps from KNF are based on a simple principal - an elastic diaphragm, fixed on its edge, moves up

More information

DIAPHRAGM VACUUM PUMPS

DIAPHRAGM VACUUM PUMPS DIAPHRAGM VACUUM PUMPS FOR THE STERILIZATION AND DRYING DATA SHEET E180 N 836 APE, basic model N 836.3 AP.40 E, with magnetic valve Concept The one and two-headed Diaphragm Pumps from KNF are based on

More information

DIAPHRAGM VACUUM PUMP LABOPORT N FT.18

DIAPHRAGM VACUUM PUMP LABOPORT N FT.18 DIAPHRAGM VACUUM PUMP LABOPORT N 81.3 FT.18 DATA SHEET E 26 Technical features 1% oil-free transfer thereby pure transferring, evacuation and compression of gases High level of vapor and condensate compatibility

More information

MEMBRAN-DIAPHRAGM LIQUID PUMPS

MEMBRAN-DIAPHRAGM LIQUID PUMPS MEMBRAN-DIAPHRAGM LIQUID PUMPS NF 1.30 NF 1.30 KTDCG Concept KNF diaphragm liquid pumps are based on the principle of the oscillating displacement pump which is remarkably simple in design. The circular

More information

CUSTOMIZED PUMP SOLUTIONS FOR DOD AND CIJ PRINTING SYSTEMS

CUSTOMIZED PUMP SOLUTIONS FOR DOD AND CIJ PRINTING SYSTEMS CUSTOMIZED PUMP SOLUTIONS FOR DOD AND CIJ PRINTING SYSTEMS KNF gas and liquid pumps in action: digital inkjet printers Reliable ink transfer robust and MAINTENANCE-free KNF gas and liquid pumps are used

More information

Recirculating Cooler C 900

Recirculating Cooler C 900 Operating Instructions Read and observe these Operating Instructions! Recirculating Cooler C 900 KNF Neuberger GmbH Alter Weg 3 79112 Freiburg Germany Tel. +49 (0)7664 / 5909-0 Fax +49 (0)7664 / 5909-99

More information

KNF LABORATORY EQUIPMENT KNOWING WHAT COUNTS

KNF LABORATORY EQUIPMENT KNOWING WHAT COUNTS KNF LABORATORY EQUIPMENT KNOWING WHAT COUNTS 5 Rotary evaporation / Distillation 13 Degassing 15 Filtration / SPE 17 Fluid Aspiration 19 Metering / TRANSFERRING Liquids 21 Gel drying 23 Centrifugal concentration

More information

KNF LABORATORY EQUIPMENT KNOWING WHAT COUNTS

KNF LABORATORY EQUIPMENT KNOWING WHAT COUNTS KNF LABORATORY EQUIPMENT KNOWING WHAT COUNTS 5 ROTARY EVAPORATION / DISTILLATION 13 DEGASSING 15 FILTRATION / SPE 17 FLUID ASPIRATION 19 METERING / TRANSFERRING LIQUIDS 21 GEL DRYING 23 CENTRIFUGAL CONCENTRATION

More information

KNF LABORATORY EQUIPMENT KNOWING WHAT COUNTS

KNF LABORATORY EQUIPMENT KNOWING WHAT COUNTS KNF LABORATORY EQUIPMENT KNOWING WHAT COUNTS 5 ROTARY EVAPORATION / DISTILLATION 15 DEGASSING 17 FILTRATION / SPE 19 FLUID ASPIRATION 21 METERING / TRANSFERRING LIQUIDS 23 GEL DRYING 25 CENTRIFUGAL CONCENTRATION

More information

Laboport Chemically-resistant Laboratory Pumps and Systems

Laboport Chemically-resistant Laboratory Pumps and Systems Operating Instructions Read and observe these Operating Instructions! Laboport Chemically-resistant Laboratory Pumps and Systems N 810 FT.18 N 820 FT.18 N 840 FT.18 N 840.1.2 FT.18 N 810.3 FT.18 N 820.3

More information

DIAPHRAGM PUMP OEM KNF /18 N TRANSLATION OF ORIGINAL OPERATING AND INSTALLATION INSTRUCTIONS ENGLISH

DIAPHRAGM PUMP OEM KNF /18 N TRANSLATION OF ORIGINAL OPERATING AND INSTALLATION INSTRUCTIONS ENGLISH KNF 308934-308937 09/18 OEM N 2400.15 TRANSLATION OF ORIGINAL OPERATING AND INSTALLATION INSTRUCTIONS ENGLISH DIAPHRAGM PUMP Note! Before operating the pump and the accessories, please read the operating

More information

Vacuum Controller with Control Unit VC 900

Vacuum Controller with Control Unit VC 900 Operating Instructions Read and observe these operating instructions! Vacuum Controller with Control Unit VC 900 KNF Neuberger GmbH Alter Weg 3 79112 Freiburg Germany Tel. +49 (0)7664 / 5909-0 Fax +49

More information

Vacuum Pumps for moist Gases. Self-drying Vacuum Pump for moist Gases. Series LABOPORT SD N FT Vacuum Pump. Spare parts.

Vacuum Pumps for moist Gases. Self-drying Vacuum Pump for moist Gases. Series LABOPORT SD N FT Vacuum Pump. Spare parts. Data Sheet E 272 LABOPORT SD Self-drying Vacuum Pump for moist Gases Series LABOPORT SD N 82.3 FT.4.18 Vacuum Pump Technical features: Pure transferring and evacuation Highly compatible with vapours and

More information

PERFORMANCE DATA Type Delivery Vacuum atm. Pressure Weight (l/min) (mbar absolute) Press (bar g) (kg)

PERFORMANCE DATA Type Delivery Vacuum atm. Pressure Weight (l/min) (mbar absolute) Press (bar g) (kg) TEMPERATURE-RESISTANT AND HEATED DIAPHRAGM GAS SAMPLING PUMPS DATA SHEET E78 N 36. ST.16 E, temperatureresistant N 36. ST.11 E with thermostatic N 1 ST.26 E with electronic Concept The temperature-resistant

More information

PERFORMANCE DATA Type Delivery Vacuum atm. Pressure Weight (l/min) (mbar abs) Press. (bar g) (kg)

PERFORMANCE DATA Type Delivery Vacuum atm. Pressure Weight (l/min) (mbar abs) Press. (bar g) (kg) MINI-DIAPHRAGM VACUUM PUMPS & COMPRESSORS N85, N85.3, N86 SECTION 41.23 N85.3KNI Concept The Mini-Diaphragm vacuum pumps from KNF are based on a simple principal - an elastic diaphragm, fixed on its edge,

More information

TEMPERATURE-RESISTANT AND HEATED DIAPHRAGM GAS SAMPLING PUMPS

TEMPERATURE-RESISTANT AND HEATED DIAPHRAGM GAS SAMPLING PUMPS TEMPERATURE-RESISTANT AND HEATED DIAPHRAGM GAS SAMPLING PUMPS N 012 ST.16 E, temperature resistant Concept The temperature-resistant and heated Diaphragm Vacuum Pumps from KNF are based on a simple principal

More information

LABOPORT. Chemically-resistant Laboratory Pumps with Modular Accessories. Operating Instructions for Laboratory Pumps. and for LABOPORT Systems

LABOPORT. Chemically-resistant Laboratory Pumps with Modular Accessories. Operating Instructions for Laboratory Pumps. and for LABOPORT Systems LABOPORT Chemically-resistant Laboratory Pumps with Modular Accessories Operating Instructions for Laboratory Pumps and for LABOPORT Systems SR..., SH, SC, SCC UN810FTP UN820FTP UN840FTP UN810.3FTP UN820.3FTP

More information

Vacuum pump systems. Operating Instructions Read and observe these Operating Instructions! SC 950 SEM 950 SH 950 SR 950

Vacuum pump systems. Operating Instructions Read and observe these Operating Instructions! SC 950 SEM 950 SH 950 SR 950 Operating Instructions Read and observe these Operating Instructions! Vacuum pump systems SC 950 SEM 950 SH 950 SR 950 KNF Neuberger GmbH Alter Weg 3 D-79112 Freiburg Germany Phone ++49 / (0)7664 / 5909-0

More information

Instruction Manual. IT20K, IT100, IT300 and IT800 Inlet Traps. A Issue F. ITC800 Inlet Chemical Trap. ITD20K Inlet Desiccant Trap

Instruction Manual. IT20K, IT100, IT300 and IT800 Inlet Traps. A Issue F. ITC800 Inlet Chemical Trap. ITD20K Inlet Desiccant Trap Instruction Manual A441-01-880 Issue F IT20K, IT100, IT300 and IT800 Inlet Traps Description ITO20K Inlet Catchpot ITC20K Inlet Chemical Trap ITD20K Inlet Desiccant Trap ITF20K Inlet Dust Filter ITO100

More information

Chemical resistant Vacuum Pumps

Chemical resistant Vacuum Pumps Chemical resistant Vacuum Pumps C300 / C400 / C410 / C510 / C600 / C610 English Operating Manual WIGGENS labortechnik GmbH Mühsamstrasse 3610249 Berlin Germany Fon:+49 30 42105470 Fax:+49 30 42105971 E-Mail:

More information

Diaphragm pump 4 - headed

Diaphragm pump 4 - headed Operation Manual (EN) Translation of the german original manual Diaphragm pump 4 - headed Model: 67000062 412743-23 2016-10-17 Gardner Denver Thomas GmbH Am Vogelherd 20 98693 Ilmenau Germany T +49 3677

More information

Operation Manual. Diaphragm pumps 2-headed. Types MP 101 Zp, MP 201 Ep MPC 101 Zp, MPC 201 Ep

Operation Manual. Diaphragm pumps 2-headed. Types MP 101 Zp, MP 201 Ep MPC 101 Zp, MPC 201 Ep Operation Manual Diaphragm pumps 2-headed Types MP 101 Zp, MP 201 Ep MPC 101 Zp, MPC 201 Ep 400170 2007-11-16 We are constantly working on the further development of all our product types. Reprinting or

More information

Betriebsanleitung Operating Instructions

Betriebsanleitung Operating Instructions Betriebsanleitung Operating Instructions Oil mist filter idealvac.com (505)872-0037 idealvac.com ONF 16 PK 0213 BE/G (0811) ONF 25/25L/25XL Table of contents Table of contents 1 About this manual......................................

More information

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS INSTRUCTIONS FOR: INFRARED IP55 HEATER MODEL:- QZWP45N Thank you for purchasing a Consort Claudgen product. Manufactured to a high standard this product will, if used according to these instructions and

More information

Operating Instruction Centrifugal fans without scroll (Translation of the Original) BA-RLE-AC /2014 RLE RLA

Operating Instruction Centrifugal fans without scroll (Translation of the Original) BA-RLE-AC /2014 RLE RLA Operating Instruction Centrifugal fans without scroll (Translation of the Original) EN RLE RLA Content 1. Important information 2. Safety notes 3.Technical description 4. Transport 5. Mounting / Installation

More information

Operating instructions

Operating instructions Operating instructions (Translation of the original operating instructions) Type TEKA FILTERCUBE-MV TEKA Absaug- und Entsorgungstechnologie GmbH Industriestraße 13 D-46342 Velen Postfach 1137 D-46334 Velen

More information

Instruction Manual. Mink. Claw Vacuum Pumps MM 1402 AV, MM 1502 AV. Busch Produktions GmbH Schauinslandstraße 1, Maulburg Germany

Instruction Manual. Mink. Claw Vacuum Pumps MM 1402 AV, MM 1502 AV. Busch Produktions GmbH Schauinslandstraße 1, Maulburg Germany Instruction Manual Mink Claw Vacuum Pumps MM 1402 AV, MM 1502 AV Busch Produktions GmbH Schauinslandstraße 1, 79689 Maulburg Germany 0870156906/A0000_en / Original instructions / Modifications reserved

More information

Adsorption dryer SDAT

Adsorption dryer SDAT Solutions to your fluid power problems Adsorption dryer SDAT Operating instructions Issue 04/2004 DRUMAG GmbH Fluidtechnik Glarnerstrasse 2 D-79713 Bad Säckingen Telefon: +49 (0)7761 / 5505-0 Fax: +49

More information

User s Guide ENGLISH. Other languages available on our website:

User s Guide ENGLISH. Other languages available on our website: User s Guide ENGLISH Other languages available on our website: www.gilson.com. 1 SAFETY SYMBOLS USED 3 2 INTENDED USE 3 This equipment generates, uses and can radiate radio frequency energy and, if not

More information

Instruction Manual. IT20K, IT100, IT300 and IT800 Inlet Traps. idealvac.com (505) idealvac.com. ITC800 Inlet Chemical Trap

Instruction Manual. IT20K, IT100, IT300 and IT800 Inlet Traps. idealvac.com (505) idealvac.com. ITC800 Inlet Chemical Trap Instruction Manual A441-01-880 Issue G Original IT20K, IT100, IT300 and IT800 Inlet Traps idealvac.com (505)872-0037 idealvac.com Description ITO20K Inlet Catchpot ITC20K Inlet Chemical Trap ITD20K Inlet

More information

Sip Vacuum Cleaner 1400/35 Wet & Dry

Sip Vacuum Cleaner 1400/35 Wet & Dry Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

Instruction Manual. Seco. Dry-running Rotary Vane Vacuum Pumps SV 1003 D, SV 1005 D

Instruction Manual. Seco. Dry-running Rotary Vane Vacuum Pumps SV 1003 D, SV 1005 D Instruction Manual Seco Dry-running Rotary Vane Vacuum Pumps SV 1003 D, SV 1005 D Busch Vyroba CZ s.r.o. Svárovská 620, CZ 460 01, Liberec 11 Czech Republic 0870140843/A0002_en / Original instructions

More information

THE NEW GENERATION VACUUM PUMP SYSTEM SC

THE NEW GENERATION VACUUM PUMP SYSTEM SC THE NEW GENERATION VACUUM PUMP SYSTEM SC 920 with wireless remote control Fast and precise from afar: Vacuum pump system with wireless remote control The new vacuum pump system SC 920 now supports remote

More information

Operating manual BDC-654 BDC-654. EN - Version 1.1. Gebruikershandleiding. Operating manual.

Operating manual BDC-654 BDC-654. EN - Version 1.1. Gebruikershandleiding. Operating manual. Operating manual BDC-654 Operating manual BDC-654 EN - Version 1.1 Gebruikershandleiding Operating manual BDC-654 2/16 EC DECLARATION OF CONFORMITY in accordance with Appendix II sub A of Directive 98/37/EC

More information

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM 216279-000 rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM IDENTIFYING YOUR SYSTEM IOM216279-000 The HOTSTART heating system is designed to heat fluids for use in marine

More information

Instruction Manual PB 0003 D. Rotary Vane Vacuum Pumps. Busch Produktions GmbH Schauinslandstraße 1, Maulburg Germany

Instruction Manual PB 0003 D. Rotary Vane Vacuum Pumps. Busch Produktions GmbH Schauinslandstraße 1, Maulburg Germany Instruction Manual R5 Rotary Vane Vacuum Pumps PB 0003 D Busch Produktions GmbH Schauinslandstraße 1, 79689 Maulburg Germany 0870167899/A0001_en / Original instructions / Modifications reserved 10/10/2017

More information

Instruction Manual. Mink. Claw Vacuum Pumps MM 1324 AV, MM 1202 AV, MM 1252 AV, MM 1322 AV US Version

Instruction Manual. Mink. Claw Vacuum Pumps MM 1324 AV, MM 1202 AV, MM 1252 AV, MM 1322 AV US Version Instruction Manual Mink Claw Vacuum Pumps MM 1324 AV, MM 1202 AV, MM 1252 AV, MM 1322 AV US Version Busch Manufacturing LLC 516 Viking Drive Virginia Beach, VA 23452 USA 0870207808/-_en / Original instructions

More information

Diaphragm pumps. Operation Manual. Models: 2019C-02 (230V / 50Hz) 2019B-01 (115V / 60Hz) 2019C-50 (230V / 50Hz)

Diaphragm pumps. Operation Manual. Models: 2019C-02 (230V / 50Hz) 2019B-01 (115V / 60Hz) 2019C-50 (230V / 50Hz) Operation Manual (EN) Translation of the german original manual Diaphragm pumps Models: 2019C-02 (230V / 50Hz) 2019B-01 (115V / 60Hz) 2019C-50 (230V / 50Hz) 2019 2017-02-08 We are constantly working on

More information

T-SERIES. Wall & Panel Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

T-SERIES. Wall & Panel Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz T-SERIES Wall & Panel Models Installation, Set-up and Operating Instructions Stock Ref. Nos. WIRED 456166A (9" WL) 456167A (9" PL) 456174A (12" WL) 456175A (12" PL) WIRELESS 456170A (9" WL) 456171A (9"

More information

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2 Cleaning unit for coolant :_decftez`_>r_fr] Book No.: 1271526-02 V2 Alfa Laval Separation AB Separator Manuals, dept. SKEL S-147 80 Tumba, Sweden Telephone: +46 8 53 06 50 00 Telefax: +46 8 53 03 10 40

More information

ANLAGENBAU HEAT EXCHANGER w w w. a nla g enba u-b oehm er. d e Version 05/2015

ANLAGENBAU HEAT EXCHANGER w w w. a nla g enba u-b oehm er. d e Version 05/2015 ANLAGENBAU HEAT EXCHANGER Table of Contents 1.0 General Information 1.2 User Instructions 1.3 Proper Use 1.4 General Safety Rules 2.0 Design and Function 3.0 Installation 3.1 Setting up the Plate Heat

More information

Original Operating Instructions V-VTE

Original Operating Instructions V-VTE Edition: 2.2.2012 BA 187-EN Original Operating Instructions V-VTE V-VTE 3 6 8 10 V-Serie V-Series Drehschieber Rotary Vane Table of contents Table of contents 1 Foreword...................................................................

More information

Vacuum Switch, Differential Pressure Adapter, Switching Amplifier

Vacuum Switch, Differential Pressure Adapter, Switching Amplifier Operating Manual Incl. EU Declaration of Conformity Vacuum Switch, Differential Pressure Adapter, Switching Amplifier VSC150, SV tina42e1-b (2017-03) 1 Product Identification In all communications with

More information

Operating Instructions

Operating Instructions Operating Instructions BA-003 Read and understand this manual before use. Keep this manual for future reference. CONFORMS TO UL STD.No.1017 Certified to CSA STD C22.2 No.243-10 For questions or concerns

More information

PCMini52 Digital RH & Temperature Mini Probe User s Manual

PCMini52 Digital RH & Temperature Mini Probe User s Manual PCMini52 Digital RH & Temperature Mini Probe User s Manual 97300 Issue 1, March 2012 Michell Instruments Inside front cover (blank) PCMini52 2009-2012 Michell Instruments This document is the property

More information

Operation Manual. Diaphragm pumps. MP 054 Zp, MPC 054 Zp MP 104 Ep, MPC 104 Ep

Operation Manual. Diaphragm pumps. MP 054 Zp, MPC 054 Zp MP 104 Ep, MPC 104 Ep Operation Manual Diaphragm pumps Types MP 054 Zp, MPC 054 Zp MP 104 Ep, MPC 104 Ep 4000542 2008-03-20 We are constantly working on the further development of all our product types. Reprinting or reproduction

More information

Operating Instructions

Operating Instructions Translation of the original instructions Hena 200/300 Rotary Vane Pump Operating Instructions PD 0042 BEN/D (1108) EN Table of contents Table of contents 1 About this manual...............................................

More information

HazLoc Essential Guides:

HazLoc Essential Guides: HazLoc Essential Guides: Intertek Deeside Lane, Chester, CH1 6DD UK hazloc@intertek.com +44 1244 882590 www.intertek-hazloc.com Contents Contents... 1 Introduction... 1 Introduction to Ex... 1 ATEX Overview...

More information

Operating Instructions

Operating Instructions Operating Instructions TEKA Cartmaster Type PF-W 1, PF-W 2 TEKA Absaug- und Entsorgungstechnologie GmbH Industriestraße 13 D-46342 Velen Postfach 1137 D-46334 Velen Tel.: +49 (0) 2863 9282-0 Fax: +49 (0)

More information

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

Steam Trap BK 45 BK 45-U BK 45-LT BK 46 Steam Trap BK 45 BK 45-U BK 45-LT BK 46 Original Installation Instructions 810437-08 Contents Foreword... 3 Availability... 3 Formatting features in the document... 3 Safety... 3 Use for the intended purpose...

More information

Operating Instructions

Operating Instructions Translation of the original instructions Hena 400/630 Rotary Vane Pump Operating Instructions PD 0043 BEN/D (1108) EN Table of contents Table of contents 1 About this manual...............................................

More information

Operation Manual. Scroll pumps. Dry Run II

Operation Manual. Scroll pumps. Dry Run II Operation Manual Scroll pumps Types Dry Run I Dry Run II 460002 2004-05-19 We are constantly working on the further development of all our product types. Reprinting or reproduction of this manual, including

More information

Whole Room Dryer WRD, WRD/110

Whole Room Dryer WRD, WRD/110 Whole Room Dryer WRD, WRD/110 User Instructions Whole Room Dryers CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE 03-8117-0000 Iss.1 12/06 Fig 1 Fig 2 Fig 3 Fig 4 CONTENTS Page 1 Product information...................4

More information

AZN ATEX INSTALLATION AND MAINTENANCE

AZN ATEX INSTALLATION AND MAINTENANCE ZerAx AZN ATEX INSTALLATION AND MAINTENANCE 924714-0 English 924714-0 GB ZerAx axial flow fans type AZN ATEX Installation and maintenance 1. Application 2. Handling 2.1 Marking 2.2 Weight 2.3 Temperature

More information

OPTIWAVE X500 Supplementary Instructions

OPTIWAVE X500 Supplementary Instructions OPTIWAVE X500 Supplementary Instructions OPTIWAVE 3500 C OPTIWAVE 6500 C OPTIWAVE 7500 C Supplementary Instructions for ATEX applications KROHNE CONTENTS OPTIWAVE X500 1 General safety information 4 1.1

More information

MP 2401 E, MP 1801 Z, MP 1201 T

MP 2401 E, MP 1801 Z, MP 1201 T Operation Manual Diaphragm pumps 8-headed Types MP 2401 E, MP 1801 Z, MP 1201 T MPC 2401 E, MPC 1801 Z, MPC 1201 T 400152 2003-10-27 We are constantly working on the further development of all our product

More information

CRU-S Series Stainless Steel Condensate Recovery Unit

CRU-S Series Stainless Steel Condensate Recovery Unit IM-UK-CRU-S UK Issue 1 CRU-S Series Stainless Steel Condensate Recovery Unit 1. Safety information 2. General product information 3. Installation 4. Commissioning 5. Storage, shutdown and equipment protection

More information

TQ Series. Electronic Control Pump Instruction Manual. 50Hz. ISO 9001 Certified Walrus Pump Co., Ltd.

TQ Series. Electronic Control Pump Instruction Manual. 50Hz. ISO 9001 Certified Walrus Pump Co., Ltd. TQ Series Electronic Control Pump Instruction Manual 50Hz ISO 9001 Certified Walrus Pump Co., Ltd. EC Declaration of Conformity Manufacturer: Walrus Pump Co., Ltd. Address: No. 83-14, Dapiantou, Sanjhih

More information

STORAGE, ERECTION, OPERATION AND MAINTENANCE MANUAL FOR CENTRIFUGAL FANS MODEL - MXE

STORAGE, ERECTION, OPERATION AND MAINTENANCE MANUAL FOR CENTRIFUGAL FANS MODEL - MXE ISO 9001 : 2000 STORAGE, ERECTION, OPERATION AND MAINTENANCE MANUAL FOR CENTRIFUGAL FANS MODEL - MXE CUSTOMER : 1 CONTENTS 1 SAFETY... 5 1.1 General... 6 1.2 Description of symbols and pictograms... 6

More information

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage - Liquid Ring Vacuum Pump One Stage LPH 60527 Pressure Range: Suction Range: 120 to 1013 mbar 200 to 800 m³/h CONSTRUCTION Sterling SIHI liquid ring vacuum pumps have a simple but robust construction with

More information

Silent TS. Nr / Ideas for dental technology / A. Made in Germany

Silent TS. Nr / Ideas for dental technology / A. Made in Germany Silent TS Nr. 2921-0050 / 2921-1050 21-9191 30102012 / A Made in Germany Ideas for dental technology 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Silent TS Nr. 2921-0050

More information

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i. Additional Operating Instructions SITRANS F Vortex flowmeters Ex-i Edition 09/2018 CONTENTS 1 Safety instructions 3 1.1 General notes... 3 1.2 EU conformity... 3 1.3 Approval according to the IECEx scheme...

More information

GRUNDFOS INSTRUCTIONS. Sololift2 C-3. Installation and operating instructions

GRUNDFOS INSTRUCTIONS. Sololift2 C-3. Installation and operating instructions GRUNDFOS INSTRUCTIONS Sololift2 C-3 Installation and operating instructions English (US) English (US) Installation and operating instructions Original installation and operating instructions. CONTENTS

More information

OPTIBAR DP 7060 Supplementary Instructions

OPTIBAR DP 7060 Supplementary Instructions OPTIBAR DP 7060 Supplementary Instructions Differential pressure transmitter Category ATEX II 1/2G, 2G Ex db ia IIC T6...T1 Ga/Gb, Gb IECEx Ex db ia IIC T6...T1 Ga/Gb, Gb Housing Aluminium: Single chamber,

More information

Vacuum Pump Kit User Manual

Vacuum Pump Kit User Manual Vacuum Pump Kit User Manual 2I-03640-4 Vacuum Pump Kit User Manual 2I-03640-4 Vacuum Pump Kit Vacuum Pump Kit P/N GS03640 CONTENTS 1. INTRODUCTION... 3 2. CHECKLIST OF CONTENTS... 4 3. OPERATION OF THE

More information

WC2 & WC3 Installation & Maintenance Instructions

WC2 & WC3 Installation & Maintenance Instructions WC2 & WC3 Installation & Maintenance Instructions Please leave this instruction booklet with the home owner as it contains important guarantee, maintenance and safety information WC3 shown WC2 WC3 IMPORTANT

More information

Instruction Manual. Puma. Vacuum Booster WP 4500 B. Ateliers Busch S.A. Zone industrielle, 2906 Chevenez Switzerland

Instruction Manual. Puma. Vacuum Booster WP 4500 B. Ateliers Busch S.A. Zone industrielle, 2906 Chevenez Switzerland Instruction Manual Puma Vacuum Booster WP 500 B Ateliers Busch S.A. Zone industrielle, 2906 Chevenez Switzerland 0870559398/A0002_en / Original instructions / Modifications reserved 06/06/2018 Table of

More information

Original Operating Instructions V-VC

Original Operating Instructions V-VC Edition: 1.12.2009 BA 231-EN Original Operating Instructions V-VC V-VC 50 75 100 150 V-Serie V-Series Drehschieber Rotary Vane Table of contents Table of contents 1 Foreword...................................................................

More information

Recirculating Cooler SRC14

Recirculating Cooler SRC14 Recirculating Cooler SRC14 Instructions for use Version 2.0 Tank cover Flow control valve 90 o Elbow Control panel Outlet nozzle Inlet nozzle Cooling coil Circulation tank Maintenance panel Drain with

More information

LV100 Standard LV100PC Pull Cord LV100T Timer LV100H Humidistat LV100HP Humidistat and Pull Cord LV100PIR

LV100 Standard LV100PC Pull Cord LV100T Timer LV100H Humidistat LV100HP Humidistat and Pull Cord LV100PIR Installation and operating instructions LV100 Standard LV100PC Pull Cord LV100T Timer LV100H Humidistat LV100HP Humidistat and Pull Cord Safety extra low voltage toilet/bathroom 100mm fan range Integral

More information

VS PD03 Scroll Pump and Components Replacement

VS PD03 Scroll Pump and Components Replacement vacuum technologies VS PD03 Scroll Pump and Components Replacement FIELD INSTALLATION INSTRUCTIONS DRAFT 2/25/09 Part Number 699910017 Rev. A February 2009 Varian Field Instruction Sheet VS PD03 Scroll

More information

Mechanical seals external, single or double, to DIN EN 12756

Mechanical seals external, single or double, to DIN EN 12756 INSTALLATION AND OPERATING MANUAL Translation of the original manual Series SCK Bearing pedestal group: 0 Mechanical seals external, single or Keep for future use! This operating manual must be strictly

More information

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable Smart Smart IR model (check applicable) is recognized as serviceable Service instruction SALES DATE MANUFACTURED ON (DATE): SOLD APPROVAL MARK SMART-EN-04 BLAUBERG Company is happy to offer your attention

More information

User instructions. VA20HD, VA55HD, VA55IND and VA75IND. Commercial wet/dry vacuum cleaners CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE

User instructions. VA20HD, VA55HD, VA55IND and VA75IND. Commercial wet/dry vacuum cleaners CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE User instructions VA20HD, VA55HD, VA55IND and VA75IND Commercial wet/dry vacuum cleaners CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE 03-8112-0000 Iss.3 07/08 http://www.truvox.com/products/vacuums/valet_aqua

More information

ANNEX GD-CERT-EX-EN SIT

ANNEX GD-CERT-EX-EN SIT SITEX ATEX Couplings ATEX ANNEX GD-CERT-EX-EN SIT S.p.A. Viale A. Volta, 2-20090 Cusago (MI) - Italy Tel. +39.02891441 Fax +39.0289144291 - info@sitspa.it www.sitspa.com ATEX Annex This Annex is an integral

More information

Aluminum Heating Mantles

Aluminum Heating Mantles Aluminum Heating Mantles ON/OFF HOT User Guide Version 1.3 ON/OFF IEC power inlet socket Power supply switch (large-volume models). Power to either the lower part of the element or the upper and lower

More information

Instruction Manual. Rotary Vane Vacuum Pumps KB 0010 E, KB 0016 E KC 0010 E, KC 0016 E

Instruction Manual. Rotary Vane Vacuum Pumps KB 0010 E, KB 0016 E KC 0010 E, KC 0016 E Instruction Manual R5 Rotary Vane Vacuum Pumps KB 0010 E, KB 0016 E KC 0010 E, KC 0016 E Busch Vyroba CZ s.r.o. Svárovská 620, CZ 460 01, Liberec 11 Czech Republic 0870169526/A0001_en / Original instructions

More information

VC-1, VC-1-SL, VC-2-L, VC-2-SL

VC-1, VC-1-SL, VC-2-L, VC-2-SL Pre-Cooling Unit Series VC VC-1, VC-1-SL, VC-2-L, VC-2-SL Instruction Manual Version 1.00.02 Dear customer, we have made up this operating manual in such a way that all necessary information about the

More information

OPERATING MANUAL English Chemical Resistant Diaphragm Pump

OPERATING MANUAL English Chemical Resistant Diaphragm Pump OPERATING MANUAL English Chemical Resistant Diaphragm Pump C300 / C400/ C410 / C510/ C600 / C610 Room 303, Hall C, Office Building M8, No. 1 Jiuxianqiao East Road, Chaoyang District, Beijing 100015, China

More information

MICRO-KJELDAHL EQUIPMENT ( MM SERIES ) OPERATING AND SAFETY INSTRUCTIONS

MICRO-KJELDAHL EQUIPMENT ( MM SERIES ) OPERATING AND SAFETY INSTRUCTIONS MICRO-KJELDAHL EQUIPMENT ( MM SERIES ) OPERATING AND SAFETY INSTRUCTIONS MICRO-KJELDAHL EQUIPMENT ( MM SERIES ) OPERATING AND SAFETY INSTRUCTIONS CONTENTS PAGE 1 INTRODUCTION... 1 2 SAFETY INFORMATION...

More information

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR 7 783 DETACTOGYR Flame Safeguard The... together with the QRA50M / QRA51M form a self-checking flame supervision system (DETACTOGYR ) designed for use with continuously operating oil or gas burners or

More information

Operation Manual. Scroll pumps. Types scrollvac S 10 scrollvac S

Operation Manual. Scroll pumps. Types scrollvac S 10 scrollvac S Operation Manual Scroll pumps Types scrollvac S 10 scrollvac S 15 460004 2010-01-05 We are constantly working on the further development of all our product types. Reprinting or reproduction of this manual,

More information

CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE

CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE User instructions Model X46 Escalator and Travelator cleaner CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE 03-7845-0000 Iss.1 07/04 Fig 1 Fig 2 2 Contents Page 1 Product information... 4 1.1

More information

Operating Instructions

Operating Instructions Translation of the original instructions Hena 60/100 Rotary Vane Pump Operating Instructions PD 0040 BEN/D (1108) EN Table of contents Table of contents 1 About this manual...............................................

More information

1592P01. for liquids in piping DN

1592P01. for liquids in piping DN 1 594 1592P01 Flow switch for liquids in piping DN 20 200. QVE1901 Contact load / switching capacity: max. AC 230 V, 1 A, 26 VA max. DC 48 V, 1 A, 20 W Nominal pressure PN25 Manual setting of contact type

More information

Operation Manual R205BV, R209BV

Operation Manual R205BV, R209BV Operation Manual R205BV, R209BV 1 Safety Instruction The rotary evaporator is manufactured according to current methods and accepted safety regulations. However, risks still exist during the installation,

More information

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage - Liquid Ring Vacuum Pump One Stage LPH 50523 Pressure Range: Suction Range: 120 to 1013 mbar 70 to 500 m³/h CONSTRUCTION Sterling SIHI liquid ring vacuum pumps have a simple but robust construction with

More information

air pump 2700/4500 ? 2YEAR GUARANTEE UK AIRPUMP _33435 CASC /10/ :16 Page 1

air pump 2700/4500 ? 2YEAR GUARANTEE UK AIRPUMP _33435 CASC /10/ :16 Page 1 33719-000 UK AIRPUMP 2700-4500_33435 CASC.450 13/10/2011 09:16 Page 1 2823 1820 1380 air pump 2700/4500 Hozelock Ltd. Midpoint Park, Birmingham B76 1AB. England Tel: +44 (0) 121 313 1122 info@hozelock.com

More information

irconcentre.co.uk airooncentre.co.uk

irconcentre.co.uk airooncentre.co.uk Installation and maintenance instructions DX100 Standard DX100PC Pull Cord DX100T Timer DX100H Humidistat DX100HP Humidistat and Pull Cord DX100PIR Integral Body Movement Sensor DX100VTD Delay Timer Toilet/Bathroom

More information

Maximum surface temperature 150 C. Highly combustable materials must not come into contact with the discharge pipework or machine body.

Maximum surface temperature 150 C. Highly combustable materials must not come into contact with the discharge pipework or machine body. Oper at i ng I nst r uct i ons and Spar epar t sli st ( Or i gi nali nst r uct i ons) SL 1520 BE11/ 1988/ 2GB02/ 12 Health & Safety Static electricity. Ensure, that where required, the ancillaries are

More information

OPERATION AND MONTAGE MANUAL ROOF FANS

OPERATION AND MONTAGE MANUAL ROOF FANS NO RFEC/U/2017-1 (EN) (valid since 18.08.2017) ROOF FANS RF/EC...-... / RFV/EC...-... Venture Industries Sp. z o.o. is not responsible for any damage caused by improper use of the fan and reserves the

More information

TRASCO ATEX Couplings

TRASCO ATEX Couplings TRASCO ATEX Couplings ATEX ANNEX GRM-CERT-EX-EN SIT S.p.A. Viale A. Volta, 2-20090 Cusago (MI) - Italy Tel. +39.02891441 Fax +39.0289144291 - info@sitspa.it www.sitspa.it ATEX Annex This Annex is an integral

More information

Flameproof Manual Call Points

Flameproof Manual Call Points Operating instructions Additional languages www.r-stahl.com CS & Clifford & Snell Contents General Information.... Manufacturer.... Information regarding the operating instructions.... Further documents....

More information

Mechanical Seal RG-4 stationary, double, liquid sealed

Mechanical Seal RG-4 stationary, double, liquid sealed Series SCK INSTALLATION AND OPERATING MANUAL Translation of the original manual Mechanical Seal RG-4 stationary, double, liquid sealed Keep for future use! This operating manual must be strictly observed

More information

OPERATION AND MONTAGE MANUAL ROOF FANS

OPERATION AND MONTAGE MANUAL ROOF FANS NO RF/U/2017 (ENGLISH) (valid since 13.10.2017) ROOF FANS RF / RFV Venture Industries Sp. z o.o. is not responsible for any damage caused by improper use of the fan and reserves the right to modify this

More information

Bagless upright. vax.co.uk. Vax Careline: (UK) (ROI) Mach 1 series Mach 2 series. Vax model number: Version 1.

Bagless upright. vax.co.uk. Vax Careline: (UK) (ROI) Mach 1 series Mach 2 series. Vax model number: Version 1. U91-M1 & M2 Mach Series User Guide v1.2:user Guide 31/08/2010 19:19 Page 1 Vax Careline: (UK) 0844 412 8455 (ROI) 1-800 928 308 Bagless upright MACH Vax model number: Mach 1 series Mach 2 series WARNING:

More information

WET & DRY GARAGE VAC 20L CAPACITY WATT 1.5M MOTOR TANK STEEL HOSE KP702 ON BOARD ACCESSORY STORAGE SUCTION STAINLESS

WET & DRY GARAGE VAC 20L CAPACITY WATT 1.5M MOTOR TANK STEEL HOSE KP702 ON BOARD ACCESSORY STORAGE SUCTION STAINLESS WET & DRY GARAGE VAC 20L CAPACITY 1.5M SUCTION HOSE STAINLESS STEEL TANK ON BOARD ACCESSORY STORAGE 1250 WATT MOTOR KP702 Table of Contents 20L WET & DRY GARAGE VAC Know Your Product...1 Vacuum Safety

More information

THERMOFILM CONVECTIVE PANEL HEATER INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Models: CP 2400 CP 2000 CP 1500 CP 1000 TABLE OF CONTENTS

THERMOFILM CONVECTIVE PANEL HEATER INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Models: CP 2400 CP 2000 CP 1500 CP 1000 TABLE OF CONTENTS THERMOFILM CONVECTIVE PANEL HEATER Rev C JUL13 INSTALLATION, OPERATION AND MAINTENANCE MANUAL Models: CP 2400 CP 2000 CP 1500 CP 1000 TABLE OF CONTENTS 1. Important Safety Instructions 2. Specification

More information

CERAMIC PUMPS FGP. Horizontal Liquid Ring Pumps Solid and gas-tight silicate ceramic for gases and vapours.

CERAMIC PUMPS FGP. Horizontal Liquid Ring Pumps Solid and gas-tight silicate ceramic for gases and vapours. CERAMIC PUMPS FGP Horizontal Liquid Ring Pumps Solid and gas-tight silicate ceramic for gases and vapours. FGP THE SOPHISTICATED PUMP CONCEPT If you want to solve demanding pumping tasks in the industry

More information