AVTI Multifunctional self - acting controller

Size: px
Start display at page:

Download "AVTI Multifunctional self - acting controller"

Transcription

1 AVTI Multifunctional self - acting controller Description / Application AVTI is a self - acting combined controller developed for controlling small heat units with a room heating system and a hot service water system. The controller is specially developed for flat systems supplied from a secondary connected District Heating System, a block heating system or a central located boiler system in a dwelling house. (See fig. 2) AVTI is connected to the primary heating system as well as the cold service water system. To avoid risk leaking from the one media to the other AVTI is equipped with a double sealing. Between the sealing there is a bore to the outside of the valve so that in case of leakage from one sealing, the media can escape through the bore. For a proper functioning of the AVTI it is recommended to use filter in the system according to the system drawing. Fig. 1 AVTI Fig. 2 SIBC VD.GB.B7.2 Danfoss 8/25 1

2 Ordering Type DN Setting range Connections ISO 228/1 Code No. AVTI o C G ½ A 3L355 AVTI o C G ½ A 3L3515 Spare parts Description Sensor element with complete gland Code No. 3L355 Function A schematic drawing in fig. (3 and 4) shows the principle of the valve. The control functions in the controller are: 1. Differential pressure controller 2. Hydraulic proportional controller for controlling of domestic hot service water 3. Thermostatic valve for controlling of domestic hot service water 4. Domestic hot water priority function The differential pressure controller controls the differential pressure across the room heating system. The basic function of the controller for Hot Service Water System is a hydraulic proportional controller, which controls the primary flow proportional to the hot service water flow rate. The control valve also contains a thermostatic valve parallel connected for adapting the Hot Water temperature according to set value. The setting range of the valve is C (6-65 C). The thermostatic valve maintains a stand by temperature in the heat exchanger. Fig. 3 In case of domestic hot water taping, the priority function in the controller reduces the flow rate in the room heating system. Fig. 4 Principle of the system drawing 2 VD.GB.B7.2 Danfoss 8/25 SIBC

3 Technical data Type 3L355 3L3515 Pressure stage PN 1 PN 1 Max. test pressure 16 bar 16 bar Range of supply temperature 65-9 C 7-9 C* Temperature setting at domestic hot service water C 6-65 C* k v (domestic hot service water) see fig. 6 see fig. 6.1 k v (room heating system) see fig. 5 see fig. 5.1 Max. sensor temperature 9 C 9 C Max. operating pressure in the heating supply net. 2 bar (2 kpa) 4 bar (4 kpa) Max. closing pressure 6 bar (6 kpa) 6 bar (6 kpa) Length of the capillary tube.5 m.5 m ΔP available for the heating system 12-2 kpa (see Fig. 8) 8-2 kpa (see Fig. 8) Approvals VA VA * T ww T prim - 1 K( C) : The set point of DHW must be 1 K( C) lower than the actual supply temperature. 3L355 3L3515 kvs(kv)/ Q1 [m3/h] kvs(kv) Q Fig. 5 Full priority to room heating system (3L355) kvs(kv) / Q1 [m3/h] Fig. 5.1 Full priority to room heating system (3L3515) kvs(kv)/ Q1 [m3/h] kvs(kv) Q kvs(kv) / Q1 [m3/h] Fig. 6 Domestic Hot Water (3L355) Fig. 6.1 Domestic Hot Water (3L3515) Pv (kpa) Q2[l/h] Fig. 7 Pressure drop across the diaphragm element for the proportional valve (3L355, 3L3515). SIBC VD.GB.B7.2 Danfoss 8/25 3

4 Sizing Electronic valve sizing program avialable on request ΔP heating system The ΔP available for the room heating system can be seen from Fig. 8: Example: Heating system Capacity: 8 kw ΔT heating system: 3 C Circulated flowrate in the room heating system = 229 l/h 3 ΔP available for the heating system is 15 kpa (see Fig. 8). p available in room heating system Pa [kpa] Flow in room heating system [l/h] Fig. 8 p available in room heating system Noise approximation Δp diferential pressure over AVTI Q1 total flow on primary side (room heating system + hot water service) 45 p=4 bar p=2 bar Noise level db(a) p=1 bar p=.5 bar Maximum differential pressure for 3L355 is 2 bar. 4 VD.GB.B7.2 Danfoss 8/25 SIBC

5 Sizing Example 1: Δp v = 2 kpa Q 2 = 84 l/h Temperature conditions 7/2-1/5 Taping temperature will be 47 C Example 2: Q 2 = 84 l/h T set = 55 C Temperature conditions 7/2-1/5 Needed Δp over AVTI is 35 kpa Quick calculation diagrams* 3L355 7/2-1/ Tset [ C] Q2 [l/h] 9/25-1/ Tset [ C] Q2 [l/h] 3L3515 7/2-1/63 Tset [ C] P v [kpa] Q2 [l/h] 9/25-1/65 Tset [ C] P v [kpa] Q2 [l/h] *Xp can be up to ±3 C SIBC VD.GB.B7.2 Danfoss 8/25 5

6 Connections 1 Primary inlet in the heat exchanger 2 To room heating system 3 From primary heating system 4 Secondary inlet in the heat exchanger 5 Cold service water supply VD.GB.B7.2 Danfoss 8/25 SIBC

7 Design Proportional actuator Pos. Description Material 1 Housing 2 Seat CuZn36Pb2As 3 Cone 4 Diaphragm EPDM/PA Differential pressure actuator 11 Cone CuZn39Pb3 12 Housing 13 Diaphragm EPDM/PA 14 Seat Controller 18 Housing CuZn36Pb2As 19 Cone CuZn39Pb3 2 Stuffing box CuZn36Pb2As O-rings EPDM Thermostat 27 Rubber cone EPDM 28 Sensor Sensor gland CuZn36PbAs 3 Sensor gasket EPDM SIBC VD.GB.B7.2 Danfoss 8/25 7

8 Dimensions 8 VD.GB.B7.2 Danfoss 8/25 SIBC

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 The XB is a brazed plate heat exchanger designed for use with district heating systems (i.e. air conditioning,

More information

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Data sheet Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 IHPT The XB is a brazed plate heat exchanger designed for use with district heating systems

More information

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Data sheet Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 IHPT The XB is a brazed plate heat exchanger designed for use with district heating systems

More information

Automatic balancing valves ASV-PV (new generation) DN 32-50

Automatic balancing valves ASV-PV (new generation) DN 32-50 Automatic balancing valves ASV-PV (new generation) DN 32-50 ASV-PV DN 32-50 Description ASV whiteboard animation SMT/SI ASV valves are automatic balancing valves. Together with Danfoss presetting radiator

More information

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting For reversed flow direction Thermostatic Radiator Valves Thermostatic valve body with and without presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / For reversed flow direction For reversed

More information

Flush individual room control for floor heating systems

Flush individual room control for floor heating systems Multibox Flush individual room control for floor heating systems Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGiNEERiNG ADVANTAGE Multibox is used for decentralized control

More information

TRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield

TRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield TRV pack Eclipse Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield IMI HEIMEIER / Thermostatic heads and Radiator valves /

More information

Multibox. Floor Heating Controller Flush individual room control for floor heating systems

Multibox. Floor Heating Controller Flush individual room control for floor heating systems Multibox Floor Heating Controller Flush individual room control for floor heating systems IMI HEIMEIER / Floor Heating Control / Multibox Multibox K, RTL and K-RTL Multibox K, RTL and K-RTL is used for

More information

Balancing & Control. Frese PV Compact. Differential Pressure Control Valve

Balancing & Control. Frese PV Compact. Differential Pressure Control Valve Balancing & Control Frese PV Compact Differential Pressure Control Valve Balancing & Control Frese PV Compact Differential Pressure Control Frese Innovative solutions from Frese balance global HVAC systems

More information

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting Calypso exact Thermostatic Radiator Valves With stepless precision presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Calypso exact Calypso exact Calypso exact thermostatic valve bodies are

More information

Data Sheet. Compact Mixing Shunt for Floor Heating, FHM-Cx. Application:

Data Sheet. Compact Mixing Shunt for Floor Heating, FHM-Cx. Application: Data Sheet Compact Mixing Shunt for Floor Heating, FHM-Cx Application: FHM-C1 Mixing shunt FHM-C/ FHM-C Mixing shunt FHM-C Mixing shunt FHM-C The Danfoss floor heating compact mixing shunts are used for

More information

ThermoDual Domestic hot water charging system

ThermoDual Domestic hot water charging system ThermoDual Domestic hot water charging system Description/Application ThermoDual is the compact and effective domestic hot water (DHW) charging system. Due to the consistent use of carefully selected components

More information

Thermostatic valves with radiator connection systems

Thermostatic valves with radiator connection systems Multilux Eclipse Thermostatic valves with radiator connection systems with two-point connection for two-pipe heating systems, with automatic flow limitation IMI HEIMEIER / Thermostatic heads and Radiator

More information

Multilux 4-Eclipse-Set

Multilux 4-Eclipse-Set Multilux -Eclipse-Set Design-Edition with two-point connection, angle and straight type, for R / and connection, with automatic flow limitation IMI HEIMEIER / Design-Edition / Multilux -Eclipse-Set Multilux

More information

FHM-Cx Mixing Shunts for Floor Heating

FHM-Cx Mixing Shunts for Floor Heating FHM-Cx Mixing Shunts for Floor Heating Application Mixing shunt FHM-C5/C6 (UPS pump) The Danfoss compact mixing shunts are used for regulation of flow and supply temperature in hydronic floor heating systems.

More information

Thermostatic three-way valve body. Thermostatic Radiator Valves without presetting, with automatic bypass control

Thermostatic three-way valve body. Thermostatic Radiator Valves without presetting, with automatic bypass control Thermostatic three-way valve body Thermostatic Radiator Valves without presetting, with automatic bypass control IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Thermostatic three-way valve body

More information

Multibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off

Multibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off Multibox 4 Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off IMI HEIMEIER / Floor Heating Control / Multibox 4 Multibox 4 RTL and K-RTL and K-RTL is

More information

FHM-Cx Mixing Shunts for Floor Heating

FHM-Cx Mixing Shunts for Floor Heating Data Sheet FHM-Cx Mixing Shunts for Floor Heating Application A self-acting proportional regulator is used to regulate the supply temperature. The regulator ensures that the desired supply temperature

More information

Technical paper Selection of district heating house stations

Technical paper Selection of district heating house stations MAKING MODERN LIVING POSSIBLE Technical paper Selection of district heating house s Herman Boysen, Product Application Manager, Danfoss A/S Published in EuroHeat & Power English Edition III 2004 districtenergy.danfoss.com

More information

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services TA-COMFORT-S Prefabricated units Heating interface unit for surface heating and hot water services IMI TA / Control valves / TA-COMFORT-S TA-COMFORT-S All in one design with STAP differential pressure

More information

Herz York Direct Heat Interface Unit

Herz York Direct Heat Interface Unit www.herzvalves.com Herz York Direct Heat Interface Unit The Modern Solution for Apartment Heating and Domestic Hot Water Services General Description The Herz York Direct HIU is suitable for all community

More information

Partner Valve/High Quality Ball Valve LENO MSV-S

Partner Valve/High Quality Ball Valve LENO MSV-S Partner Valve/High Quality Ball Valve LENO MSV-S Description LENO MSV-S is a partner valve for all manual balancing valves in the LENO family. LENO MSV- S can also be applied as a high quality ball valve.

More information

Eclipse F. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

Eclipse F. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation Eclipse F Adaptative Flow Control Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Eclipse F Eclipse F The thermostatic

More information

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25) Data sheet Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25) Description STW871 The controllers are: - Type-tested acc. to EN 14597 and protect against exceeding temperatures:

More information

Akva Vita TDP-F District heating flat station for direct heating and domestic hot water systems

Akva Vita TDP-F District heating flat station for direct heating and domestic hot water systems Akva Vita TDP-F District heating flat station for direct heating and domestic hot water systems Akva Vita TDP-F Table of contents Akva Vita TDP-F...1 Table of contents...1 Safety notes...2 Delivery...2

More information

Akva Vita TDP District heating flat station for direct heating and domestic hot water systems

Akva Vita TDP District heating flat station for direct heating and domestic hot water systems Akva Vita TDP District heating flat station for direct heating and domestic hot water systems Akva Vita TDP Table of contents Akva Vita TDP... 1 Table of contents... 1 Safety notes... 2 Delivery... 2 Transport

More information

Domestic hot water (DHW) The substation can be supplied with connection pipes for DHW cylinder on the supply or return line.

Domestic hot water (DHW) The substation can be supplied with connection pipes for DHW cylinder on the supply or return line. MAKING MODERN LIVING POSSIBLE VX Solo II Substation for single-family, semi-detached and terraced houses as well as flats District heating substation for indirect heating. With connection pipes for W cylinder.

More information

Temperature controller for steam (PN 25) AVT / VGS - external thread

Temperature controller for steam (PN 25) AVT / VGS - external thread Data sheet Temperature controller for steam (PN 25) AVT / VGS - external thread Description The controller has a control valve VGS, thermostatic actuator and handle for temperature setting. Thermostatic

More information

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control. product selection data Compact comfort module DHW management possibility Multi zone option control Easy installation Comfort module with two-zone kit Single-zone comfort module Comfort Module Range for

More information

RA 2000 Series RA 15/6T & TB Conversion Valve

RA 2000 Series RA 15/6T & TB Conversion Valve RA 2000 Series RA 15/6T & TB Conversion Valve Applications: RA15/6T Internal bypass allowing for series piping to the radiators/baseboards. This series piping provides continuous flow but the supply water

More information

Eclipse. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

Eclipse. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation Eclipse Adaptative Flow Control Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Eclipse Eclipse The thermostatic

More information

Systems for central heating

Systems for central heating www.far.eu Highlight Systems and Components for central heating Components for renewable energy systems Pressfar Fittings Presetting valves and thermostatic head Balancing devices Zone valves Metering

More information

product overview ProControl

product overview ProControl product overview ProControl 2016 product overview ProControl 2016 4 The company AFRISO Sp. z o.o. was founded in 1997. Since that time we keep doing our best to increase AFRISO brand awareness among Installers.

More information

Akva Lux TDP-F District heating flat station for direct heating and domestic hot water systems

Akva Lux TDP-F District heating flat station for direct heating and domestic hot water systems Akva Lux TDP-F District heating flat station for direct heating and domestic hot water systems Akva Lux TDP-F Table of contents Akva Lux TDP-F... 1 Table of contents... 1 Safety notes... 2 Delivery...

More information

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting Standard Thermostatic Radiator Valves Thermostatic valve body without presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Standard Standard The Standard thermostatic valve bodies are used

More information

Contact person RISE Date Reference Page Björn Folkeson P03675B 1 (11) Energy and circular economy

Contact person RISE Date Reference Page Björn Folkeson P03675B 1 (11) Energy and circular economy Contact person RISE Björn Folkeson 2017-08-15 7P03675B 1 (11) Energy and circular economy +46 10 516 54 46 bjorn.folkeson@ri.se Gemina Termix A/S Navervej 15-17 DK-7451 SUNDS Danmark Testing of a HIU according

More information

CALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB

CALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB Set point thermostatic regulating unit 8 series FM 65 00 CALEFFI 090/8 GB replaces dp 090/5 GB Function The thermostatic regulating unit is made to be used in radiant panel systems, in combination with

More information

manifold, for radiators

manifold, for radiators MMA, for radiators Eco-friendly materials, low lead content Quiet Precise and linear Dimension: DN 0 Temperature: C to + C Pressure class: PN 0 Description Area of use The Evoflow radiator is especially

More information

RA15/6T & TB Conversion Valve

RA15/6T & TB Conversion Valve Applications: continue on. This provides continuous flow, but inherent to series piping the supply water temperature will decrease as it flows through the system and when it mixes with return water from

More information

IMI Heimeier Kit Hydroca ble

IMI Heimeier Kit Hydroca ble IMI Heimeier Kit Hydroca ble Thermostatic valves with radiator connection systems Thermostatic valve and lockshield with tube-bend for the installation as angle form or axial form with press- or sliding

More information

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB 4 RESET ON DHW CH FAULT SATK wall-mounted heat interface unit Fitted for connection to DHW storage SATK4 series ACCREDITED CALEFFI 6/4 GB ISO 9 FM 64 ISO 9 No. The latest generation of heat interface units

More information

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems E-Z Valve Thermostatic valves with radiator connection systems For single and two-pipe heating systems IMI HEIMEIER / Thermostatic heads and Radiator valves / E-Z Valve E-Z Valve E-Z Valve with immersion

More information

Danfoss prefabricated floorheatingunit Type FH-G/FH-GS/FH-GR/FH-GRS

Danfoss prefabricated floorheatingunit Type FH-G/FH-GS/FH-GR/FH-GRS data sheet Danfoss prefabricated floorheatingunit Type FH-G/FH-GS//S Application The Danfoss prefabricated underfloorheating (UFH) unit for distribution of heating and domestic water is primarily designed

More information

Hydraulic balance in a district cooling system

Hydraulic balance in a district cooling system Article Hydraulic balance in a district cooling system Herman Boysen, Product Application Manager, Danfoss A/S, Published in DBDH 2003 (www.dbdh.dk) www.danfoss.com Herman Boysen Product Application Manager,

More information

Thermostatic valve bodies

Thermostatic valve bodies Thermostatic valve bodies for single pipe heating systems Thermostatic valves with radiator connection systems IMI HEIMEIER / Thermostatic heads and Radiator valves / Thermostatic valve bodies for single

More information

New TERMOVAR Loading Unit. The link between bio-energy boiler and storage tank system

New TERMOVAR Loading Unit. The link between bio-energy boiler and storage tank system New TERMOVAR Loading Unit The link between bio-energy boiler and storage tank system New TERMOVAR Loading Unit The link between bio-energy boiler and storage tank system TERMOVAR LOADING UNIT is a pre-fabricated,

More information

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Reduced Installation time Precision regulation Minimal tooling required 100% tested prior to packaging High quality

More information

Technical paper Hydraulic balance in a district cooling system

Technical paper Hydraulic balance in a district cooling system MAKING MODERN LIVING POSSIBLE Technical paper Herman Boysen, Product Application Manager, Danfoss A/S Published in DBDH 2003 (www.dbdh.dk) districtenergy.danfoss.com TECHNICAL PAPER Hydraulic balance in

More information

Wall-hung boilers. Spare parts catalogue. ecotec plus

Wall-hung boilers. Spare parts catalogue. ecotec plus Spare parts catalogue Wall-hung boilers ecotec plus VU 126/6-5 OV (plus 412) VU 156/6-5 OV (plus 415) VU 186/6-5 OV (plus 418) VU 246/6-5 OV (plus 424) 0020223106_01 GB 10/2015 Content General view of

More information

IN LINE MIXED FLOW DUCT FANS AND ELECTRIC HEATER TD-MIXVENT HEATING System

IN LINE MIXED FLOW DUCT FANS AND ELECTRIC HEATER TD-MIXVENT HEATING System HEATING System fan (from model 25) and a MBE electric heater installed on the discharge side of the fan. + MBE ELECTRIC HEATER MBE heater type - Insulated element rods. - Automatic overheat thermostat

More information

HEAT INTERFACE UNITS (Sanitary Hot Water Only)

HEAT INTERFACE UNITS (Sanitary Hot Water Only) HEAT INTERFACE UNITS (Sanitary Hot Water Only) T-FAST i20 (Sanitary Hot Water Only) 20 The T-Fast i20 is an instantaneous domestic hot water production module that produces a flow rate of 20L per/min at

More information

Calypso TRV-3. (for the Nordic countries) Thermostatic radiator valves With presetting

Calypso TRV-3. (for the Nordic countries) Thermostatic radiator valves With presetting Calypso TRV-3 (for the Nordic countries) Thermostatic radiator valves With presetting IMI TA / Thermostatic heads and Radiator valves / Calypso TRV-3 (for the Nordic countries) Calypso TRV-3 (for the Nordic

More information

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve Connection and energy management compact unit 2850 series ACCREDITED CALEFFI 01259/14 GB ISO 9001 FM 21654 ISO 9001 No. 0003 Function The connection and energy management compact unit enables combining

More information

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT DOC1066 GB STOKVIS ENERGY SYSTEMS 96R WALTON ROAD EAST MOLESEY SURREY KT8 0DL TEL: 08707 707 747 FAX: 08707 707 767 E-MAIL:info@stokvisboilers.com

More information

Thermostatic valve bodies

Thermostatic valve bodies Thermostatic valve bodies for all thermostatic heads and actuators Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING ADVANTAGE ThermosTaTic valve bodies Table of contents

More information

CALEFFI. Anti-condensation circulation unit. 282 series 01225/14 GB. replaces dp 01225/11. Code completion Setting 45 C 55 C 60 C 70 C.

CALEFFI. Anti-condensation circulation unit. 282 series 01225/14 GB. replaces dp 01225/11. Code completion Setting 45 C 55 C 60 C 70 C. Anti-condensation circulation unit 8 series ACCREDITED ISO 9 F 654 ISO 9 No. CALEFFI 5/4 GB replaces dp 5/ Function The anti-condensation circulation unit performs the function of connecting the solid

More information

Installation, Operation and Maintenance Instructions Thermaflow E Plate Heat Exchanger Package OM013

Installation, Operation and Maintenance Instructions Thermaflow E Plate Heat Exchanger Package OM013 Installation, Operation and Maintenance Instructions Thermaflow E Plate Heat Exchanger Package OM013 Calorifiers Heat Exchangers Pressurisation Units Sales Tel: 01457 835700 Sales Fax: 01457 832700 E-mail:

More information

Multibox. Flush Individual Room Control for Floor Heating Systems. To be precise.

Multibox. Flush Individual Room Control for Floor Heating Systems. To be precise. Flush Individual Room Control for Floor Heating Systems To be precise. Contents Page Multibox K, Multibox RTL and Multibox K-RTL Description Construction Application 4 Temperature Setting 4 Function Article

More information

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W 594 59P0 Flow switch for liquids in piping DN 0 00. QE90 Contact load / switching capacity: Nominal pressure PN5 Manual setting of contact type (NO / NC) Housing IP 65 / safety class II Maintenance free

More information

Contact person RISE Date Reference Page Daniel Månsson P (13) Energy and circular economy

Contact person RISE Date Reference Page Daniel Månsson P (13) Energy and circular economy Contact person RISE Daniel Månsson 2018-08-07 8P04823 1 (13) Energy and circular economy +46 10 516 53 28 daniel.mansson@ri.se Flamco LTD Washway Lane, St. Helens Merseyside WA10 6PB Great Britain Testing

More information

HERZ Differential Pressure Control Valve 4002

HERZ Differential Pressure Control Valve 4002 HERZ Differential Pressure Control Valve 4002 Data sheet 4002, Issue 0118 Dimensions in mm B1 B2 1 4002 41 1 4002 61 1 4002 71 1 4002 42 1 4002 62 1 4002 72 1 4002 43 1 4002 63 1 4002 73 1 4002 44 1 4002

More information

Say heating. Say Herz. HERZ-Supply Engineering

Say heating. Say Herz. HERZ-Supply Engineering HERZ-Supply Engineering Medium Temperature Control Pressure Control Fittings Control Fittings Lock Shields and Isolators Accessories Spare Parts Say heating. Say Herz. HERZ Valves UK Progress House [ Moorfield

More information

Stokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing

Stokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing Stokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing Water Heater Supplement STOKVIS ENERGY SYSTEMS 96R Walton Road East Molesey Surrey KT8 0DL Tel: 020 8783 3050 / 0870 7707747 Fax: 020

More information

CALEFFI. Anti-condensation recirculation and distribution unit. 281 series 01224/14 GB. Replaces dp 01224/12 GB. Function

CALEFFI. Anti-condensation recirculation and distribution unit. 281 series 01224/14 GB. Replaces dp 01224/12 GB. Function Anti-condensation recirculation and distribution unit 8 series ACCREDITED ISO 900 FM 654 ISO 900 No. 000 CALEFFI 04/4 GB Replaces dp 04/ GB GB Function The anti-condensation recirculation and distribution

More information

Design-Edition. Design-Edition Thermostatic valves and lockshields, sets

Design-Edition. Design-Edition Thermostatic valves and lockshields, sets Design-Edition Design-Edition Thermostatic valves and lockshields, sets IMI HEIMEIER / Design-Edition / Design-Edition Design-Edition The sets are an elegant solution for e. g. design radiators. A sublime

More information

Mikrotherm. Manual Radiator Valves With presetting

Mikrotherm. Manual Radiator Valves With presetting Mikrotherm Manual Radiator Valves With presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Mikrotherm Mikrotherm The Mikrotherm manual radiator valve is used in warm water pump heating systems,

More information

INSTALLATION AND SERVICING

INSTALLATION AND SERVICING INSTALLATION AND SERVICING LOGIC HIU (Heat Interface Unit) Indirect 75 Indirect 50 Direct MT Direct HT When replacing any part on this appliance, use only spare parts that you can be assured conform to

More information

Standard. thermostatic valve body without presetting

Standard. thermostatic valve body without presetting Standard thermostatic valve body without presetting Pressurisation & Water Quality Balancing & Control Thermostatic Control EnGInEErInG advantage The standard thermostatic valve bodies are used in two-pipe

More information

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production SATK0 - SATK0 series ACCREDITED ISO 900 FM 009/ GB replaces dp 009/ GB Function The latest generation of Heat Interface

More information

Akva Lux VX District heating substation for indirect heating and domestic hot water systems

Akva Lux VX District heating substation for indirect heating and domestic hot water systems Akva Lux VX District heating substation for indirect heating and domestic hot water systems Akva Lux VX Table of Contents Akva Lux VX... 1 Table of Contents... 1 Safety notes... 2 Delivery... 2 Transport

More information

Instructions for installation and use Akva Lux II VX substations 1. Contents

Instructions for installation and use Akva Lux II VX substations 1. Contents Akva Lux II VX thermostatic control Akva Lux II VX thermostatic control, and optional junction box + zone valve Akva Lux II VX (ECL 110) Akva Lux II VX HWP (ECL210) Akva Lux II VX H2WP (ECL 210) 1. Contents

More information

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional.

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional. Page 1 of 5 Application The Single Plate heat interface unit (HIU) for the generation of instantaneous domestic hot water and the direct supply of space heating. This HIU provides hydraulic separation

More information

1592P01. for liquids in piping DN

1592P01. for liquids in piping DN 1 594 1592P01 Flow switch for liquids in piping DN 20 200. QVE1901 Contact load / switching capacity: max. AC 230 V, 1 A, 26 VA max. DC 48 V, 1 A, 20 W Nominal pressure PN25 Manual setting of contact type

More information

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model MICROGENUS PLUS. R EN - Edition 02-01/04/2007

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model MICROGENUS PLUS. R EN - Edition 02-01/04/2007 SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model MICROGENUS PLUS R8215343-02EN - Edition 02-01/04/2007 Domestic Gas Boilers MICROGENUS PLUS 537814 MICROGENUS PLUS 24 MET...... 3300078 MICROGENUS PLUS 21

More information

Akva Vita Instantaneous water heater

Akva Vita Instantaneous water heater Akva Vita Instantaneous water heater Akva Vita Table of Contents Akva Vita... 1 Table of Contents... 1 Safety notes... 2 Delivery... 2 Transport and storage... 2 Mounting... 3 Pipes connections... 4 Electrical

More information

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation Standard C Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Standard C Standard C The Standard C thermostatic

More information

Installation and operation manual for mixing modules FH-MJB and FH-MJC

Installation and operation manual for mixing modules FH-MJB and FH-MJC 40 30 20 50 60 Installation and operation manual for mixing modules FH-MJB and FH-MJC Application The FH-MJB and FH-MJC mixing shunts are designed to supply floor heating areas up to approx. 40 m 2 (from

More information

FLOWRETT, TA-UNI. Thermostatic valves with radiator connection system One-pipe

FLOWRETT, TA-UNI. Thermostatic valves with radiator connection system One-pipe FLOWRETT, TA-UNI Thermostatic valves with radiator connection system One-pipe IMI TA / Thermostatic heads and Radiator valves / FLOWRETT, TA-UNI FLOWRETT, TA-UNI Compatible with most radiators on the market,

More information

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features Comfort Module Range for Monobloc Heat Pumps Quality Management Systems Comfort module with two-zone kit Single-zone comfort module 8HMA Nominal heating capacity 4- kw Nominal cooling capacity 4- kw The

More information

Contact person Date Reference Page Daniel Månsson P (13) Energy and circular economy

Contact person Date Reference Page Daniel Månsson P (13) Energy and circular economy Contact person Daniel Månsson 2017-04-18 7P01636 1 (13) Energy and circular economy +46 10 516 53 28 daniel.mansson@ri.se Fortes Import Installatie Agenturen B.V. Loodsboot 26 NL-3991 CJ Houten Nederländerna

More information

Liquid Distributor Type RD

Liquid Distributor Type RD MAKING MODERN LIVING POSSIBLE Data sheet Liquid Distributor Type RD The RD refrigerant distributors distribute liquid refrigerants from the thermostatic expansion valve to individual sections of the evaporator.

More information

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function Thermostatic regulating unit for heating systems 66 series ACCREDITED ISO 9 FM 6 8/7 GB replaces dp 8/ GB Function The thermostatic regulating unit performs the function of keeping the flow temperature

More information

GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS. Spare parts suitable for LA CIMBALI

GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS. Spare parts suitable for LA CIMBALI GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS Spare parts suitable for LA CIMBALI LA CIMBALI heating elements heating elements heating elements for coffee machine No.

More information

PROPAK THERMAL. Packaged Plate Heat Exchanger

PROPAK THERMAL. Packaged Plate Heat Exchanger PROPAK THERMAL Packaged Plate Heat Exchanger 2 PROPAK THERMAL Applications Care Homes Student Accommodation Sports & Leisure Hotels Restaurants Accommodation Accommodation Sport & Leisure Care Homes PROPAK

More information

MAKING MODERN LIVING POSSIBLE. Akva Lux II TDP-F. Instructions for installation and use. Danfoss District Energy

MAKING MODERN LIVING POSSIBLE. Akva Lux II TDP-F. Instructions for installation and use. Danfoss District Energy MAKING MODERN LIVING POSSIBLE Instructions for installation and use Danfoss District Energy substations Type 004U8264 Type 0048089 Cover for wall-mounting Type 0048044 Cover for recess mounting 1.0 Contents

More information

TA-MATIC. Mixing valves Thermostatic mixing valve for domestic hot water

TA-MATIC. Mixing valves Thermostatic mixing valve for domestic hot water TA-MATIC Mixing valves Thermostatic mixing valve for domestic hot water IMI TA / Potable water / TA-MATIC TA-MATIC Thermostatic mixing valve for control of domestic hot water systems in apartment blocks

More information

RA2000 Commercial TRVs

RA2000 Commercial TRVs RA2000 Commercial TRVs www.heating.danfoss.co.uk Danfoss Limited Ampthill Road Bedford MK42 9ER E: ukheating@danfoss.com W: www.heating.danfoss.co.uk Reception Tel: 01234 364621 Fax: 01234 219705 UK Sales

More information

Thermostatic head K. with contact or immersion sensor. Thermostat-Köpfe For medium temperature control

Thermostatic head K. with contact or immersion sensor. Thermostat-Köpfe For medium temperature control Thermostatic head K with contact or immersion sensor Thermostat-Köpfe For medium temperature control IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Thermostatic head K with contact or immersion

More information

THERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE PRODUCTION RANGE IRON PIPE CODE CONNECTION

THERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE PRODUCTION RANGE IRON PIPE CODE CONNECTION THERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE CT0031.0_10 EN August 2016 THERMOSTATIC RADIATOR VALVES * * * * 028 * LICENSED USE OF TRADEMARK NR. 43 PRODUCTION RANGE IRON

More information

Metering systems 0548EN April 2014

Metering systems 0548EN April 2014 08EN April 0 0U8 GEY - Y - Y (GE- series) 900 000/ 00 00A/ 800 00L/ Versions and product codes Product code Type Heat exchanger nominal power GEY, - GEY and production GEY and production Table - Product

More information

Floor Control Set. Floor Heating Controller For constant control of the supply temperature

Floor Control Set. Floor Heating Controller For constant control of the supply temperature Floor Control Set Floor Heating Controller For constant control of the supply temperature IMI HEIMEIER / Floor Heating Control / Floor Control Set Floor Control Set The Floor Control Set with return addition

More information

Contact person Date Reference Page Daniel Månsson P07886E-rev2 1 (14) Energy and bioeconomy

Contact person Date Reference Page Daniel Månsson P07886E-rev2 1 (14) Energy and bioeconomy Contact person Daniel Månsson 2016-04-15 5P07886E-rev2 1 (14) Energy and bioeconomy +46 10 516 53 28 Daniel.Mansson@sp.se FairHeat Ltd, 10 Stoney Street, London SE1 9AD16 United Kingdom Testing of heat

More information

The solutions are here The choice is yours...

The solutions are here The choice is yours... Hydronic Balancing and Control The solutions are here The choice is yours... 1255 products to support your business The extended Hydronic Balancing and Control product range offers a solution for every

More information

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting Standard Thermostatic Radiator Valves Thermostatic valve body without presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Standard Standard The Standard thermostatic valve bodies are used

More information

Contact person Date Reference Page Björn Folkeson P (14) Energy and bioeconomy

Contact person Date Reference Page Björn Folkeson P (14) Energy and bioeconomy Contact person Björn Folkeson 2016-11-18 6P06855 1 (14) Energy and bioeconomy +46 10 516 54 46 bjorn.folkeson@sp.se Caleffi S.p.A. S.R. 229, n. 25 IT-28010 Fontaneto d'agogna (NO) Italy Testing of heat

More information

EVAC Commercial Marine Equipment TOILET TECHNICAL DATA EVAC 90, SQUATTING TOILET. To main vacuum line, connection Ø50.

EVAC Commercial Marine Equipment TOILET TECHNICAL DATA EVAC 90, SQUATTING TOILET. To main vacuum line, connection Ø50. Date: 25 Jan 2005 Doc. 1:114E TECHNICAL DATA 5979301 EVAC 90, SQUATTING To main vacuum line, connection Ø50 Service door 600 Push button Fresh water supply connection 1/2" MPT BSP 700 700 Flushing mechanism

More information

V2, V4 and V8 Thermostats Self-acting Temperature Controls I GB-1. Characteristics. Applications. Function. Design

V2, V4 and V8 Thermostats Self-acting Temperature Controls I GB-1. Characteristics. Applications. Function. Design GB-1 Characteristics Closing force 200 N, 400 N and 800 N For heating or cooling valves Sturdy and reliable Temperature range 0 to 160ºC (-30 to 280ºC on request) Applications The temperature controller,

More information

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model CLAS. R EN - Edition 01-01/02/2007

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model CLAS. R EN - Edition 01-01/02/2007 SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model CLAS R8215828-01EN - Edition 01-01/02/2007 3300187 CLAS 24 NG (EAA1)...... 3300189 CLAS 24 CF NG (EAA1)...... 3300188 CLAS 28 NG (EAA1)...... Reference

More information

caleffi hydronic valves page 1 of 12

caleffi hydronic valves page 1 of 12 caleffi hydronic valves page 1 of 12 page 2 of 12 MANUAL RADIATOR VALVES 1601811 - Series 340 1601812 - Series 341 1603748 - Seies 411 1603749 - Series 412 CONVERTIBLE RADIATOR VALVES 1601816 - Series

More information

V-exact II. Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting

V-exact II. Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting V-exact II Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / V-exact II V-exact II V-exact II thermostatic valve

More information