Design-Edition. Design-Edition Thermostatic valves and lockshields, sets
|
|
- Janice Lucas
- 6 years ago
- Views:
Transcription
1 Design-Edition Design-Edition Thermostatic valves and lockshields, sets
2 IMI HEIMEIER / Design-Edition / Design-Edition Design-Edition The sets are an elegant solution for e. g. design radiators. A sublime effect will always be achieved with the Design-Edition white or chrome edition. Together with the thermostatic head DX the result will be such an attractive finish where everything fits together. Key features > > Four different sets in white RAL 06 or chrome > > Covered connections to radiator and pipe for elegant design > > Elegant thermostatic head DX with closed graduation cap and locking ring cover > > V-exact II precision-presetting for precise balancing Technical description Design-Edition Sets with thermostatic valve body, radiator lockshield and thermostatic head DX. There are sets in 4 different versions in each case in white RAL 06 (valve bodies powder-coated) or chrome plated available: Straight Angle Double angle, connection right Double angle, connection left The body, which is made of brass, is designed for connection to a threaded pipe, or in conjunction with compression fittings, for connection to copper or precision steel pipes. Permitted operating temperature TB C. Permitted operating pressure PB bar. Thermostatic valve body with integrated stepless precision presetting and white protection cap. The flow of the presetting can be easily and precisely set with a key. The selected value can be read on the front of the thermostatic insert. With the key, only a specialist can create or change the setting. The stainless spindle is equipped with a double O-ring sealing. The outer O-ring is replaceable under pressure. The complete thermostatic insert can be replaced with the fitting tool without draining off the system. Radiator lockshield for shutting off, draining off and filling. Can be shut-off with a hexagonal key SW. A drain-off and filling device for / hose connection is available A drain-off and filling device for / hose connection is available as accessorie. Thermostatic head DX Liquid-filled thermostat. High pressure power, lowest hysteresis, optimal closing time. Stable control behavior even in the case of small calculated p-band variation (<K). Meet all requirements of the German EnEV and DIN V Setting range 6 C to 8 C. Valve stroke limiter. Setting numbers to. Frost protection 6 C. Max. sensor temperature 0 C. Hysteresis 0.4 K. Water temperature influence 0.7 K. Differential pressure influence 0. K. Closing time 4 min.
3 Construction Thermostatic valve body. Long-life double O-ring sealing. Precise regulating part for accurate V-exact II stepless presetting. Strong return spring in combination with high locating force ensures that the valve does not slacken off over time 4. Thrust piece for draining off. Shut-off cone Lockshield Application The Design-Edition Sets are an elegant solution for e. g. design radiators. A sublime effect will always be achieved with white or chrome edition. Together with the thermostatic head DX the result will be such an attractive finish where everything fits together. The radiator and pipe connections are completely covered. Every set contains also a cover for the thermostatic head locking ring. The thermostatic valve body is fitted with the V-exact II technology for safe presetting as standard. The lockshield makes possible the individual shut-off, drainoff and filling e. g. of radiators in order to carry out painting or maintenance work, without having to shut down other radiators. Sample application
4 IMI HEIMEIER / Design-Edition / Design-Edition Noise behaviour To ensure low-noise performance, the following conditions must be met: On the basis of experience, the differential pressure over the thermostatic valves should not exceed about kpa = 0 mbar = 0. bar. If in designing the system, higher transient differentials might be experienced in the part-load flow range, differential pressure control equipment such as a STAP Differential Pressure Controller or Hydrolux bypass valves can be used (see diagram for noise characteristic curve). Mass-flow must be correctly adjusted. The system must be completely deaerated. Notes To avoid damage and the formation of scale deposit in the hot water heating system, the composition of the heat transfer medium should be in accordance with the VDI guideline. For industrial and long-distance energy systems, see the applicable codes VdTÜV and 466/AGFW FW. A heat transfer medium containing mineral oils, or any type of lubricant containing mineral oil can have extremely negative effects and usually lead to the disintegration of EPDM seals. When using nitrite-free frost and corrosion resistance solutions with an ethylene glycol base, pay close attention to the details outlined in the manufacturers documentation, particularly concerning concentration and specific additives. The thermostatic valve bodies can be used with all IMI Heimeier thermostatic heads and IMI Heimeier or IMI TA thermal or motorized actuators. The optimal tuning of the components guarantees maximum safety. When using actuators from other manufacturers, make sure that the pressure power is appropriate for thermostatic valve bodies with soft sealing valve discs. Operation Presetting The presetting can be selected steplessly between and 8. There are 7 additional marks between the preset values, thus enabling exact setting. Setting 8 corresponds to the standard setting (factory setting). The technician can undertake or change the setting with the setting key or spanner ( mm). This ensures unauthorised persons cannot tamper with the setting. Plug the setting key or universal key into the valve insert and turn until it engages in position. Turn the index of the desired setting value to the index figure of the valve insert. Withdraw the key. The setting on the valve insert is visible from the actuating direction (see fig.). Front-end visibility *) *) Index 4
5 Technical data Diagram, valve body with thermostatic head P-band [xp],0 K kv 0,0/ xp 0, K, 4, 6,,,, 7, db(a) P-band [xp],0 K kv 0,0/ xp 0, K, 4, 6, 0,,, 7, 00 0 db(a) db(a) , 0, 0, 0, p [kpa] 0, 0, ª [kg/h] p [mbar] 00 p [kpa] 0, 0, ª [kg/h] Δp [mbar] 00 Valve body (DN //) with thermostatic head P-band [xp].0k P-band [xp].0k Presetting Th.- head Kv-value 0,04 0,08 0, 0, 0,46 0,0 0, 0,4 Kv-value 0,04 0,00 0, 0,6 0,0 0,470 0,0 0,670 Kvs 0,04 0, 0,8 0, 0,4 0,6 0,740 0,860 Permitted differential pressure, during which the valve is kept closed Δp [bar] EMO T-TM/NC EMOtec/NC EMO / EMO EIB/LON,0,, EMO T/NO EMOtec/NO Flow tolerance ± [%] Kv/Kvs = m /h at a pressure drop of bar. Sample calculation Target: Setting range Given: Heat flow Q = 8 W Temperature spread ΔT = K (6/0 C) Pressure loss, thermostatic valve ΔpV = mbar Solution: Mass flow m = Q / (c ΔT) = 8 / (,6 ) = 7 kg/h Setting range from Diagram: With P-band max.,0 K: 4, With P-band max.,0 K: 4 Kv Cv = 0,86 Kv = Cv 0,86
6 IMI HEIMEIER / Design-Edition / Design-Edition Diagram radiator lockshield kvs,74 Articles Set, straight DN EAN Article No white RAL chrome-plated Set, angle DN EAN Article No white RAL chrome-plated Set, Double angle, connection to radiator right DN EAN Article No white RAL chrome-plated Set, Double angle, connection to radiator left DN EAN Article No white RAL chrome-plated
7 Accessories Setting key For V-exact II from. EAN Article No Draining off and filling device for / -hose connection. EAN Article No Compression fitting for copper or precision steel pipes. Female thread connection Rp /8 Rp /4. Metal-to-metal joint. Brass nickel-plated. Support sleeves should be used for a pipe wall thickness of 0.8 mm. Follow the specifications of the pipe manufacturer. Ø Pipe DN EAN Article No (/ ) (/ ) Support sleeve for copper or precision steel pipe with a mm wall thickness. Brass. Ø Pipe L EAN Article No, , , , Compression fitting For multi-layer pipes. Female thread connection Rp /. Nickel-plated brass. Ø Pipe EAN Article No 6 x
8 IMI HEIMEIER / Design-Edition / Design-Edition Dimensions Ø 48 SW 7 SW 7, Ø, Ø Rp / Rp / 4±,min. 6 7± 6 7± 4,± 4,± 7± 7±, 47,± 6 47,± 4± 6 7±, 7± 4± 6 47,± 6 47,± 80 mm = 0,04 inch The products, texts, photographs, graphics and diagrams in this document may be subject to alteration by IMI Hydronic Engineering without prior notice or reasons being given. For the most up to date information about our products and specifications, please visit
Calypso exact. Thermostatic Radiator Valves With stepless precision presetting
Calypso exact Thermostatic Radiator Valves With stepless precision presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Calypso exact Calypso exact Calypso exact thermostatic valve bodies are
More informationFor reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting
For reversed flow direction Thermostatic Radiator Valves Thermostatic valve body with and without presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / For reversed flow direction For reversed
More informationIMI Heimeier Kit Hydroca ble
IMI Heimeier Kit Hydroca ble Thermostatic valves with radiator connection systems Thermostatic valve and lockshield with tube-bend for the installation as angle form or axial form with press- or sliding
More informationStandard. Thermostatic Radiator Valves Thermostatic valve body without presetting
Standard Thermostatic Radiator Valves Thermostatic valve body without presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Standard Standard The Standard thermostatic valve bodies are used
More informationThermostatic three-way valve body. Thermostatic Radiator Valves without presetting, with automatic bypass control
Thermostatic three-way valve body Thermostatic Radiator Valves without presetting, with automatic bypass control IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Thermostatic three-way valve body
More informationV-exact II. Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting
V-exact II Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / V-exact II V-exact II V-exact II thermostatic valve
More informationMultilux 4-Eclipse-Set
Multilux -Eclipse-Set Design-Edition with two-point connection, angle and straight type, for R / and connection, with automatic flow limitation IMI HEIMEIER / Design-Edition / Multilux -Eclipse-Set Multilux
More informationControl valves for floor heating systems. Floor Heating Manifolds
Control valves for floor heating systems Floor Heating Manifolds IMI HEIMEIER / Floor Heating Control / Control valves for floor heating systems Control valves for floor heating systems Supply control
More informationE-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems
E-Z Valve Thermostatic valves with radiator connection systems For single and two-pipe heating systems IMI HEIMEIER / Thermostatic heads and Radiator valves / E-Z Valve E-Z Valve E-Z Valve with immersion
More informationthermostatic valve body with stepless precision presetting
Thermostatic Radiator Valves V-exact II thermostatic valve body with stepless precision presetting Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING AVANTAGE V-exact II
More informationStandard. Thermostatic Radiator Valves Thermostatic valve body without presetting
Standard Thermostatic Radiator Valves Thermostatic valve body without presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Standard Standard The Standard thermostatic valve bodies are used
More informationThermostatic valves with radiator connection systems
Multilux Eclipse Thermostatic valves with radiator connection systems with two-point connection for two-pipe heating systems, with automatic flow limitation IMI HEIMEIER / Thermostatic heads and Radiator
More informationStandard. Thermostatic Radiator Valves Thermostatic valve body without presetting
Standard Thermostatic Radiator Valves Thermostatic valve body without presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Standard Standard The Standard thermostatic valve bodies are used
More informationStandard. thermostatic valve body without presetting
Standard thermostatic valve body without presetting Pressurisation & Water Quality Balancing & Control Thermostatic Control EnGInEErInG advantage The standard thermostatic valve bodies are used in two-pipe
More informationTRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield
TRV pack Eclipse Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield IMI HEIMEIER / Thermostatic heads and Radiator valves /
More informationEclipse F. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation
Eclipse F Adaptative Flow Control Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Eclipse F Eclipse F The thermostatic
More informationCalypso TRV-3. (for the Nordic countries) Thermostatic radiator valves With presetting
Calypso TRV-3 (for the Nordic countries) Thermostatic radiator valves With presetting IMI TA / Thermostatic heads and Radiator valves / Calypso TRV-3 (for the Nordic countries) Calypso TRV-3 (for the Nordic
More informationEclipse. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation
Eclipse Adaptative Flow Control Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Eclipse Eclipse The thermostatic
More informationMikrotherm. Manual Radiator Valves With presetting
Mikrotherm Manual Radiator Valves With presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Mikrotherm Mikrotherm The Mikrotherm manual radiator valve is used in warm water pump heating systems,
More informationFloor Control Set. Floor Heating Controller For constant control of the supply temperature
Floor Control Set Floor Heating Controller For constant control of the supply temperature IMI HEIMEIER / Floor Heating Control / Floor Control Set Floor Control Set The Floor Control Set with return addition
More informationStandard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation
Standard C Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Standard C Standard C The Standard C thermostatic
More informationRegulux. Return Lockshield Radiator lockshield with consistent presetting and drain-off facility
Regulux Return Lockshield Radiator lockshield with consistent presetting and drain-off facility IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Regulux Regulux The Regulux is used in warm water pump
More informationThermostatic valve bodies
Thermostatic valve bodies for single pipe heating systems Thermostatic valves with radiator connection systems IMI HEIMEIER / Thermostatic heads and Radiator valves / Thermostatic valve bodies for single
More informationThermostatic valve bodies
Thermostatic valve bodies for all thermostatic heads and actuators Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING ADVANTAGE ThermosTaTic valve bodies Table of contents
More informationVekotrim. Valves for radiators with integrated valve Double connection fitting with shut-off ball valves for radiators with integrated valves
Vekotrim Valves for radiators with integrated valve Double connection fitting with shutoff ball valves for radiators with IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Vekotrim Vekotrim The Vekotrim
More informationregulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge
regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge Regulux Description Separate presetting cone for consistent
More informationMultibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off
Multibox 4 Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off IMI HEIMEIER / Floor Heating Control / Multibox 4 Multibox 4 RTL and K-RTL and K-RTL is
More informationMultibox. Floor Heating Controller Flush individual room control for floor heating systems
Multibox Floor Heating Controller Flush individual room control for floor heating systems IMI HEIMEIER / Floor Heating Control / Multibox Multibox K, RTL and K-RTL Multibox K, RTL and K-RTL is used for
More informationFlush individual room control for floor heating systems
Multibox Flush individual room control for floor heating systems Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGiNEERiNG ADVANTAGE Multibox is used for decentralized control
More informationDynalux. Floor Heating Manifolds Underfl oor heating circuit manifold
Dynalux Floor Heating Manifolds Underfl oor heating circuit manifold IMI HEIMEIER / Floor Heating Control / Dynalux Dynalux Dynalux adjusts the flow rate in the individual heating circuits directly in
More informationThree-way reversing valve
Three-way reversing valve For heating and cooling systems Pressurisation & Water Quality Balancing & Control thermostatic Control engineering avantage Three-way reversing valve for the distribution of
More informationRegulux. Radiator lockshield with drain-off facility. To be precise.
Radiator lockshield with drain-off facility To be precise. Description Assembly Regulux Closing cap Thrust piece HEIMEIER radiator lockshield for shutting off, presetting, draining off and filling. Separate
More informationThermostatic head K. with contact or immersion sensor. Thermostat-Köpfe For medium temperature control
Thermostatic head K with contact or immersion sensor Thermostat-Köpfe For medium temperature control IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Thermostatic head K with contact or immersion
More informationthermostatic inserts for radiators with integrated valves
s for radiators with integrated valves Pressurisation & Water Quality Balancing & Control Thermostatic Control engineering advantage valves for radiator with integrated valve technical description heimeier
More informationMultibox. Flush Individual Room Control for Floor Heating Systems. To be precise.
Flush Individual Room Control for Floor Heating Systems To be precise. Contents Page Multibox K, Multibox RTL and Multibox K-RTL Description Construction Application 4 Temperature Setting 4 Function Article
More informationThermostatic head B. Thermostatic heads Secured model designed for public buildings
Thermostatic head B Thermostatic heads Secured model designed for public buildings IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Thermostatic head B Thermostatic head B The thermostatic head B
More informationArt-Line. Absolutely Brilliant Temperature control was never so good
Art-Line Absolutely Brilliant Temperature control was never so good Pressurisation & Water Quality Balancing & Control thermostatic Control engineering ADVANTAge art-line 16 unique decors for individualists
More informationHalo. Thermostatic heads with built-in sensor
Halo Thermostatic heads with built-in sensor IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Halo Halo The thermostatic head Halo is used to control the temperature of individual rooms using, for
More informationTA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services
TA-COMFORT-S Prefabricated units Heating interface unit for surface heating and hot water services IMI TA / Control valves / TA-COMFORT-S TA-COMFORT-S All in one design with STAP differential pressure
More informationFLOWRETT, TA-UNI. Thermostatic valves with radiator connection system One-pipe
FLOWRETT, TA-UNI Thermostatic valves with radiator connection system One-pipe IMI TA / Thermostatic heads and Radiator valves / FLOWRETT, TA-UNI FLOWRETT, TA-UNI Compatible with most radiators on the market,
More informationThermostatic head K. Thermostatic heads with built-in sensor and remote sensor
Thermostatic head K Thermostatic heads with built-in sensor and remote sensor IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Thermostatic head K Thermostatic head K The thermostatic heads K are
More informationTA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services
TA-COMFORT-S Prefabricated units Heating interface unit for surface heating and hot water services IMI TA / Prefabricated units / TA-COMFORT-S TA-COMFORT-S All in one design with differential pressure
More informationV2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS
W GE R MAN Y W GE R MAN Y V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS Design Angle left Straight W GE R MAN Y Angle right The Therafix
More informationHERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.
Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation Standard Sheet for 6823/ 6824 Edition 1000 (0999) 6823 6824 Special Models 1
More informationGlobo H. Ball valves Gunmetal ball valve
Gobo Ba vaves Gunmeta ba vave IMI EIMEIER / Shut-off vaves / Gobo Gobo Gobo is used as a versatie shut-off eement in pump hot-water heating systems. Thanks to the compact working radius of the operating
More informationThermostatic heads. Thermostatic Heads For all thermostatic valve bodies and radiators with integrated valves
Thermostatic heads Thermostatic Heads For all thermostatic valve bodies and radiators with integrated valves IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Thermostatic heads Thermostatic heads
More informationThermostatic heads. For all thermostatic valve bodies and radiators with integrated valves
Thermostatic heads For all thermostatic valve bodies and radiators with integrated valves Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING ADVANTAGE ThermostatIC HEADS
More informationEnergy Saving Series RADICAL
RADICAL The Stelrad Radical Energy Saving Radiator can save up to 10.5% on energy bills, delivering higher comfort levels at a lower thermostat setting. That s radical thinking, from Stelrad. It s the
More informationRadical CPD BIM.
Radical At the forefront of innovation, Stelrad has developed the next generation in energy saving radiators, the Radical. As the first serial feed radiator this ground breaking solution reduces energy
More informationTS RD 7761 RD, 7761 RD
1/2 HERZ Calis TS RD three way valve HERZ Calis TS RD 100% three-way valve for heating and cooling Datasheet for 1 7761 RD, Issue 0716 Dimensions in mm Order number Dimension R A B C kvs dp (bar) maximum
More informationHERZ Regulating valve 4002
HERZ Regulating valve 4002 Data sheet 4002, Issue 0214 Dimensions in mm B1 B2 1 4002 41 1 4002 61 1 4002 42 1 4002 62 1 4002 43 1 4002 63 1 4002 44 1 4002 64 1 4002 45 1 4002 65 1 4002 46 1 4002 66 DN
More informationVITA ECO. Save money & energy. Highly efficient radiator saving up to 10.5% on fuel bills, at a cost effective price. 03 / 06 RANGE.
VITA ECO 03 / 06 Save money & energy. Highly efficient radiator saving up to 10.5% on fuel bills, at a cost effective price. RANGE 132 SKUs HEIGHTS (MM) 300, 500, 600 LENGTHS (MM) 400-2000 TYPES OUTPUTS
More informationHERZ Differential Pressure Control Valve 4002
HERZ Differential Pressure Control Valve 4002 Data sheet 4002, Issue 0118 Dimensions in mm B1 B2 1 4002 41 1 4002 61 1 4002 71 1 4002 42 1 4002 62 1 4002 72 1 4002 43 1 4002 63 1 4002 73 1 4002 44 1 4002
More informationInstallation and operating instructions
Installation and operating instructions To be precise. Installation and operating instructions Table of contents General notes Page Thermostatic valve 3 Faults Causes Remedial action 4 Temperature setting
More informationEMO T. Thermal actuator for heating, ventilation, and air conditioning systems. To be precise.
Thermal actuator for heating, ventilation, and air conditioning systems To be precise. Description The EMO T thermal actuator is a VDE-tested two-point actuator for connecting to room temperature controllers
More informationTA-MATIC. Mixing valves Thermostatic mixing valve for domestic hot water
TA-MATIC Mixing valves Thermostatic mixing valve for domestic hot water IMI TA / Potable water / TA-MATIC TA-MATIC Thermostatic mixing valve for control of domestic hot water systems in apartment blocks
More informationZeparo Cyclone. Automatic air vents and separators Dirt and magnetite separator with Cyclonic technology
Zeparo Cyclone Automatic air vents and separators Dirt and magnetite separator with Cyclonic technology IMI PNEUMATEX / Air Vents, Dirt Separators and Degassing / Zeparo Cyclone Zeparo Cyclone Comprehensive
More informationThermostatic heads. for all thermostatic valve bodies and radiators with integrated valves. To be precise.
Thermostatic heads for all thermostatic valve bodies and radiators with integrated valves To be precise. Thermostatic heads Table of contents Page Thermostatic heads Construction Application 4 Function
More informationConvertible radiator valve for one-pipe systems, centre distance 35 mm
Convertible radiator valve for one-pipe systems, centre distance 35 mm 56 series ACCREDITED ISO 900 FM 65 033/6 GB Function 56 series convertible radiator valves are used on one-pipe radiator systems.
More informationmanifold, for radiators
MMA, for radiators Eco-friendly materials, low lead content Quiet Precise and linear Dimension: DN 0 Temperature: C to + C Pressure class: PN 0 Description Area of use The Evoflow radiator is especially
More informationV2075, V2077 Flowshare Valve THERMOSTATIC TWO-WAY FLOWSHARE VALVE
V2075, V2077 Flowshare Valve THERMOSTATIC TWO-WAY FLOWSHARE VALVE Application Thermostatic flowshare valves control the output of radiators in vertical one-pipe heating systems. Heating water not required
More informationHERZ TS-3000 HERZ HERZ Armaturen A-1230 Vienna Richard-Strauss-Straße 22
HERZ TS-3000 HERZ-3000 Connection system for radiators Thermostatic valve and shut-off return valve Standard sheet for 3691-3694 3791 3794 Issue 0702 G 3/4 Dimensions in mm 1 3002 31 Connection nipples
More informationAutomatic balancing valves ASV-PV (new generation) DN 32-50
Automatic balancing valves ASV-PV (new generation) DN 32-50 ASV-PV DN 32-50 Description ASV whiteboard animation SMT/SI ASV valves are automatic balancing valves. Together with Danfoss presetting radiator
More informationInstallation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump
Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Reduced Installation time Precision regulation Minimal tooling required 100% tested prior to packaging High quality
More informationHERZ-Thermostatic and Return Valves. DE LUXE Edition 1000 (0999) HERZ Armaturen. Standard Sheet for DE LUXE. Richard-Strauss-Straße 22 A-1230 Wien
HERZ-Thermostatic and Return Valves Standard Sheet for DE LUXE Edition 1000 (0999) This series consists of HERZ radiator thermostats, HERZ-TS-90 thermostatic valves and HERZ return valves. These components
More informationTHERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES
FUNCTION Thermostatic expansion valves are used to regulate and cut-off the flow of the heat transfer fluid that circulates inside airconditioning system terminals (radiators, fan coils, etc.). Thermostat
More informationRadiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function
HERZ-3000 Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function Standard Sheet for 3791 3792 Edition 1000 (0999) Dimensions in mm 1 3001 01 Cone sleeve 1 3002 01 Connection
More informationAquastrom T plus Thermostatic valve with adjustable temperature control range and fixed residual volume flow for circulation pipes
Thermostatic valve with adjustable temperature control range Technical information Tender specification: Oventrop thermostatic valve Aquastrom T plus with presetting for circulation pipes. Thermal control
More informationTHERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES
FUNCTION Thermostatic expansion valves are used to regulate and cut-off the flow of the heat transfer fluid that circulates inside airconditioning system terminals (radiators, fan coils, etc.). Thermostat
More informationV2461, V2471 Verafix-VK PRE-SETTABLE H-BLOCK FOR COMPACT RADIATORS
V2461, V2471 Verafix-VK PRE-SETTABLE H-BLOCK FOR COMPACT RADIATORS PRODUCT DATA Design The H-block valve consists of: Straight valve body for floor connection or angle valve body for wall connection Valve
More informationConnection set. Radiator connection set for thermostatic and manual operation Ø 12
Connection set Radiator connection set for thermostatic and manual operation Data sheet for 1 7650 00 Issue 0405 Control valves Connection pipe Ø 12 L L = 600 1 7650 00 L = 1000 1 7650 01 Bypass bodies
More informationFor more information on Pegler Yorkshire visit Heating Controls. Radiator valves with new integral push-fit inlet
Heating Controls Radiator valves with new integral push-fit inlet Heating Controls Radiator valves with new integral push-fit inlet Terrier is a name which should need no introduction to the professional
More informationRA2000 Commercial TRVs
RA2000 Commercial TRVs www.heating.danfoss.co.uk Danfoss Limited Ampthill Road Bedford MK42 9ER E: ukheating@danfoss.com W: www.heating.danfoss.co.uk Reception Tel: 01234 364621 Fax: 01234 219705 UK Sales
More informationFunction series Thermo-electric actuator electric supply 230 V (ac) or 24 V (ac/dc)
onvertible radiator valve for one-pipe and two-pipe systems series ARIT 0/ G ISO 0 M ISO 0 No. 000 unction The series convertible radiator valve can be used both on one-pipe and two-pipe radiator systems.
More informationMeet Max. Unique AFC technology
Unique AFC technology Meet Max For the delicate egg of a Bearded Dragon to hatch, it needs to be kept at a perfectly regulated temperature. This would normally be a challenge for a standard radiator valve.
More informationRA15/6T & TB Conversion Valve
Applications: continue on. This provides continuous flow, but inherent to series piping the supply water temperature will decrease as it flows through the system and when it mixes with return water from
More informationValves, controls + systems Flow, pressure and temperature balancing
Innovation + Quality Valves, controls + systems Flow, pressure and temperature balancing Product range Flow, pressure and temperature balancing Content Page Flow, pressure and temperature balancing Necessity
More informationBrazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)
Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 The XB is a brazed plate heat exchanger designed for use with district heating systems (i.e. air conditioning,
More informationcaleffi hydronic valves page 1 of 12
caleffi hydronic valves page 1 of 12 page 2 of 12 MANUAL RADIATOR VALVES 1601811 - Series 340 1601812 - Series 341 1603748 - Seies 411 1603749 - Series 412 CONVERTIBLE RADIATOR VALVES 1601816 - Series
More informationRA 2000 Series RA 15/6T & TB Conversion Valve
RA 2000 Series RA 15/6T & TB Conversion Valve Applications: RA15/6T Internal bypass allowing for series piping to the radiators/baseboards. This series piping provides continuous flow but the supply water
More information2 DESCRIPTION OF SYSTEM COMPONENTS
2 DESCRIPTION OF SYSTEM COMPONENTS Buderus Panel Radiators Buderus Solidoflux N panel radiators are manufactured from.049 (1.25 mm) thick steel panels. They consist of water-filled steel welded radiative
More informationVHX Valve Sets with RAX Thermostatic Sensor for Designer Radiators & Bathroom Towel Rails
VHX Valve Sets with RAX Thermostatic Sensor for Designer Radiators & Bathroom Towel Rails Application VHX floor connection VHX wall connection The VHX-sets are specially designed for towel rails and designer
More informationStraight pattern thermostatic radiator valve vertical or horizontal mounting with (368T CPDLS) matching drain off lockshield
Straight pattern thermostatic radiator valve vertical or horizontal mounting with (368T CPDLS) matching drain off lockshield Straight pattern TRV & drain off lockshield pack Size Pattern No. Pack 1 Qty
More informationDynacon Eclipse. Floor Heating Manifolds Floor heating manifold with automatic flow control
Dynacon Ecipse Foor Heating Manifods Foor heating manifod with automatic fow contro IMI HEIMEIER / Foor Heating Contro / Dynacon Ecipse Dynacon Ecipse Dynacon Ecipse adjusts the fow rate in the individua
More informationSay heating. Say Herz. HERZ-Supply Engineering
HERZ-Supply Engineering Medium Temperature Control Pressure Control Fittings Control Fittings Lock Shields and Isolators Accessories Spare Parts Say heating. Say Herz. HERZ Valves UK Progress House [ Moorfield
More informationTRV & Lockshield Pack Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting with (367 CPLS) matching lockshield
TRV & Lockshield Pack Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting with (367 CPLS) matching lockshield GENERAL INFORMATION Size Pattern No. Pack 1 Qty Code Barcode Angle Pattern
More informationCONNECTION OPTIONS FOR MANIFOLDS & CONTROL UNITS
CONNECTION OPTIONS FOR MANIFOLDS & CONTROL UNITS INSTALLATION INSTRUCTIONS FOR CONTROL BOXES Pay attention to the total pressure loss when connecting UV4- to the control boxes for heating areas > 16 m²!
More informationTA-Compact-P. Giving you MORE by giving you LESS
TA-Compact-P Giving you MORE by giving you LESS control valve balancing valve 5 in 1 full measurement TA-Compact-P The new two-way pressure independent balancing and control valve for terminal units in
More information4-way valve with thermostatic option with variable centre distance and pre-adjustment for Single pipe and Dual pipe systems.
4-way valve with thermostatic option with variable centre distance and pre-adjustment for Single pipe and Dual pipe systems. CT3101.0_00 EN June 2016 o o o o Valve with pre-adjustment; Variable centre
More informationSOLUTIONS GUIDE. For total efficiency
2014-2015 SOLUTIONS GUIDE For total efficiency THERMOSTATIC RADIATOR HEADS Comap Thermostatic heads have been counted amongst the best sellers in Europe for decades, thanks to their high manufacturing
More informationUnibox Individual room temperature control and limitation of return temperature in surface heating systems
4 3 2 4 4 3 2 Unibox Individual room temperature control Technical information Tender specification: Oventrop Unibox for temperature balance of floor and wall surface by limiting the return temperature
More informationTHERMOSTATIC SINGLE-PIPE AND DOUBLE-PIPE VALVES
ST.07.05.00 THERMOSTIC SINGLE-PIPE AND DOUBLE-PIPE VALVES 1. Art.1420 THERMOSTIC SINGLE-PIPE VALVE Single-pipe valves allow manual, thermostatic or thermo-electric regulation. Separation of the lockshield
More informationSystems for central heating
www.far.eu Highlight Systems and Components for central heating Components for renewable energy systems Pressfar Fittings Presetting valves and thermostatic head Balancing devices Zone valves Metering
More informationCALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA
Thermostatic mixing valves with replaceable cartridge for centralized systems 3, 3 series CCREDITED ISO 9 FM ISO 9 No. 3 /3 N Replaces / N Function The thermostatic mixing valve is used in systems producing
More informationSTRAIGHT AND ANGLED THERMOSTATIC VALVES
ST.07.01.00 STRIGHT ND NGLED THERMOSTTIC VLVES 1. DESCRIPTION FR thermostatic valves are preset for assembly of thermostatic and thermo-electric actuators, which control opening and closure. rt. 16 Chrome-plated
More informationBrazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)
Data sheet Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 IHPT The XB is a brazed plate heat exchanger designed for use with district heating systems
More informationSAUTER Valveco compact. A pressure-independent multi-function valve
SAUTER Valveco compact A pressure-independent multi-function valve I take care of everything in one unit. Valveco compact combines a balancing valve, a control valve and a differential pressure controller.
More informationRadiator Trap Radiator Valve
Radiator Trap Radiator Valve -1 Step 0 Type/Structure/Features Please refer to this for structure and features of Radiator Trap, Radiator Valve, and Cold & Hot Water Valve. Oventrop GmbH & Co. KG For products
More informationThe New Caroma TMV20
specify.caroma.com.au The New Caroma TMV The high performance Caroma TMV Thermostatic Mixing Valve has the capacity to service multiple outlets and features a removable cartridge for ease of service. The
More informationSection - A. Radiator Valves
Section - Radiator Valves RDITOR VLVES EXMPLE OF PPLICTION 2 6 9 3 5 7 1 4 8 2 1 Thermostat adaptable valves. 2 Lockshield valves. 3 4-way thermostat adaptable valves for one-pipe and two-pipe systems.
More information