Radiator Trap Radiator Valve

Size: px
Start display at page:

Download "Radiator Trap Radiator Valve"

Transcription

1 Radiator Trap Radiator Valve -1

2 Step 0 Type/Structure/Features Please refer to this for structure and features of Radiator Trap, Radiator Valve, and Cold & Hot Water Valve. Oventrop GmbH & Co. KG For products with mark in the contents, instead of Yoshitake plate or label, original indication of Oventrop GmbH & Co. KG is attached. Please understand. Step 1 Selection Please look at the ID chart to choose the right products depending on the intended of uses Confirm the additional details on the product page. Step 2 Sizing Check the size in discharge capacity chart. Step 3 Attention for usage Please check some guidelines for optimal usage of the products such as installation. -2

3 What is Radiator Trap? It is a trap mainly installed at condensate outlet side of radiator for steam heater. Thermostatic type, such as bellows type or wax type, is used. Because heat sensitive area sensing temperature is larger than wax type, and responsiveness of temperature change is good, condensate retention is quite small and condensate is discharged quickly. Wax type Because sensor which senses temperature is capsule wax type, its structure is effective for impact pressure of water hammer, etc. What is Cold and Hot Water Valve? It is used with installed on heat release equipment using cold and hot water mainly. By regulating valve opening constant, it can be used as return valve. What is Radiator Valve? It is used with installed on heat release equipment of heater, which uses steam mainly. Flow rate can be regulated manually. -3

4 RADIATOR TRAPS/RADIATOR VALVES Control ID-Charts ID-Charts Model Type Fluid Material Max. Press. (MPa) Max. Temp. ( ) Connection Nominal Size Page TS-1A Angle type 15-25A -6 Steam condensate CAC C Inlet: JIS R (union joint) Outlet: JIS Rc TS-1S Straight type 15-25A -6 TS-3A Angle type 15-20A -8 Steam condensate CAC C Inlet: JIS R (union joint) Outlet: JIS Rc TS-3S Straight type 15-20A -8 TS-4A Wax type Angle type 15-20A -10 Steam condensate CAC C Inlet: JIS R (union joint) Outlet: JIS Rc TS-4S Wax type Straight type 15-20A -10 FV-2A FV-2S HV-3A Angle type Straight type Angle type Steam, Cold and hot water Cold and hot water CAC C CAC C Inlet: JIS Rc Outlet: JIS R (union joint) Inlet: JIS Rc Outlet: JIS R (union joint) 15-32A A A -13 HV-3S Straight type 15-20A -13-4

5 RADIATOR TRAP/RADIATOR VALVE Control ID-Charts ID-Charts Model Type Fluid Material Max. Press. (MPa) Max. Temp. ( ) Connection Nominal Size Page Angle type 15-25A series Hot water, Hot water: 1.0 Hot water: 120 C Inlet: Rp * Straight type Brass 15-25A -15 Steam Steam: 0.05 Steam: 110 C Outlet: R (union joint) Horizontal angle type 15-20A -15 Angle type 15-20A series Cold and hot water Brass C Inlet: Rp Outlet: R (union joint) Straight type 15-20A - * For the details of sensor part, please see each product page. -5

6 Radiator Trap TS-1 The TS-1 radiator trap is used for a wide variety of radiators for heating. TS-1A <Angle type> Features 1. Reduced noise. 2. of air trouble free. 3. The bellows is manufactured from selected material under strict quality control. Quick discharge of condensate from the system, and no steam leakage with long service life. 4. Never freezing. Specifications Application Maximum pressure Maximum temperature Body Valve, valve seat Material Bellows Union Connection * Available with 200 kpa (TS-1HA or TS-1HS, only 25A). Steam condensate 100 kpa * 120 C Cast bronze Brass Phosphor bronze Brass Inlet: JIS R screwed (union joint) Outlet: JIS Rc screwed TS-1S <Straight type> Dimensions (mm) and Weights (kg) TS-1A 15A 20A 25A d 1 TS-1A <Angle type> L1 H H D Weight TS-1S <Straight type> TS-1S 15A 20A 25A d 1 L1 H L H D Weight

7 TS-1 Maximum Continuous Discharge Capacity Chart W: Discharge capacity L/h P: Working differential pressure kpa This chart shows the maximum discharge. In designing a system, set a sufficient safety factor (two or three times). -7

8 Radiator Trap TS-3 The TS-3 radiator trap, like the TS-1, is bellows thermostatic type and supports a working pressure of up to 0.2 MPa. It is used for a wide variety of radiators for heating. Features 1. Compact, lightweight and reduced noise. 2. Prevents freezing damage since designed not to allow condensate to remain inside. 3. Quickly discharges cold condensate and air at the start of operation. 4. The valve and valve seat are made of stainless steel. Fluororesin is used for the cover gasket, making disassembly and assembly easy. TS-3A <Angle type> Specifications Application Working pressure Maximum temperature Body Valve Material Valve seat Thermoelement Union Dimensions (mm) and Weights (kg) TS-3A Connection Steam condensate MPa 135 C Cast bronze Brass Stainless steel Phosphor bronze Brass Inlet: JIS R screwed (union joint) Outlet: JIS Rc screwed * Recommend model TS-1H for 25A of maximum working pressure 0.2 MPa. 15A 20A d L H H Weight TS-3S <Straight type> TS-3A <Angle type> -8

9 TS-3 TS-3S 15A 20A d L L L H H Weight TS-3S <Straight type> Maximum Continuous Discharge Capacity Chart 15A, 20A W: Discharge capacity L/h P: Working differential pressure MPa This chart shows the maximum discharge. In designing a system, set a sufficient safety factor (two or three times). -9

10 Radiator Trap TS-4 Wax type The TS-4 radiator trap uses a wax type thermoelement for the heat sensing unit and supports a working pressure of up to 0.35 MPa. It is used for a wide variety of radiators for heating. Features 1. Compact, lightweight and reduced noise. 2. Freezing damage can be prevented since designed not to allow condensate to remain inside it. 3. Quickly discharges cold condensate and air at the start of operation. 4. Stainless steel made valve and valve seat. Fluororesin is used for the cover gasket, making disassembly and assembly easy. TS-4A <Angle type> Specifications Application Working pressure Maximum temperature Body Valve Material Valve seat Thermoelement Union Dimensions (mm) and Weights (kg) TS-4A 15A 20A Connection d L H Steam condensate MPa 150 C Cast bronze Stainless steel Stainless steel Brass, others Brass Inlet: JIS R screwed (union joint) Outlet: JIS Rc screwed H Weight TS-4S <Straight type> TS-4A <Angle type> -10

11 TS-4 TS-4S 15A 20A d L L L H H Weight TS-4S <Straight type> Maximum Continuous Discharge Capacity Chart 15A, 20A W: Discharge capacity L/h P: Working differential pressure MPa This chart shows the maximum discharge. In designing a system, set a sufficient safety factor (two or three times). -11

12 Radiator Valve FV-2 The FV-2 radiator valve is designed to use with radiators for heating using steam. Features 1. Totally free of leakage due to bellows pack less type. 2. Complete close with a fluororesin disc. 3. Usable for not only steam but cold and hot water. FV-2A <Angle type> Specifications Application Maximum pressure Maximum temperature Body Material Union Valve disc Connection Steam (cold and hot water) 0.3 MPa 150 C Cast bronze Brass PTFE Inlet: JIS Rc screwed Outlet: JIS R screwed (union joint) FV-2S <Straight type> Dimensions (mm) and Weights (kg) 15A 20A 25A 32A d L 1 L 2 H 1 H 2 H 3 H 4 D 1 1-1/ Weight Angle type Straight type Maximum Flow Rate Chart (For Steam) 15A 20A 25A 32A FV-2A <Angle type> Differential pressure MPa Since this table shows the maximum discharge, set a sufficient safety factor FV-2S <Straight type> (kg/h) -12

13 Radiator Valve HV-3 Return valve combined type HV-3 is used as a radiation valve and return valve for cold and hot water heat radiator. It is used in a building and housing. Features HV-3A <Angle type> 1. General valve structure and the valve is completely closed with a fluororesin disc. 2. Small handle torque by a fluororesin mold gland packing. 3. No rust and tarnish by chromium-plating on the outside. HV-3S <Straight type> Specifications Application Maximum pressure Maximum temperature Body Material Valve Brass Connection Cold and hot water 0.6 MPa 90 C Bronze Fluororesin Brass Inlet: JIS Rc screwed Outlet: JIS R screwed (union joint) When using the return valve, remove the handle after adjusting the flow rate as needed. Dimensions (mm) and Weights (kg) Angle type Weight Straight type HV-3A<Angle type> HV-3S<Straight type> -13

14 HV-3 Pressure Loss Chart Nominal size V: Flow rate L/min (A): Angle type (B): Straight type P: Pressure loss MPa Precautions for operation Tightening pressure of the packing may decrease during transportation and storing. In this case, please additionally fasten the gland nut before using the valve. If external leakage has been neglected, leakage may not stop by additional tightening. Please check the valve daily and do the additional fastening earlier. -14

15 Thermo Radiator Valve 1 Series 1 series are used for radiator heater at school, hospital, hotel and office. It can adjust the heating temperature for each rooms and control the room temperature precisely with economy. Straight valve with wax type TH sensor Features 1. Self-acting temperature regulator requires no auxiliary power. 2. Available with both hot water and steam. 3. Have a choice 3 valve types depends on pipe installation. Angle type, horizontal angle type and straight type. 4. Have a choice 3 thermostat types depends on application., wax type and remote mount type. 5. The valve automatically operates in accordance with room temperature. It prevents excess heating and leads to saving energy. Angle valve with bellows type LH sensor Horizontal angle valve with bellows type LH sensor Specifications Sensor Application Hot water Steam Maximum pressure 1.0 MPa 0.05 MPa Allowable back pressure 0.05 MPa or less Maximum temperature 120 C 110 C Material Body Valve Connection Type Bronze or Brass (nickel plate) EPDM Inlet: JIS Rp screwed Outlet: JIS R (union joint) LH TH FH Bellows Wax Remote mount Room temp. adjustable range 7-28 C 7-28 C 7-28 C Scale and adjust temperature 0: Valve completely close (differential pressure 0.1 MPa or less). : For freezing prevention Capillary length 2 m or 5 m * * Available with capillary of up to 10 meter (Model: ). Available with thermostat with remote sensor (Model: ) for the place where sensing room temperature is difficult due to obstruction. Please inquire for detail. With Remote sensor * TH type is a remodeled product of DH type and it is compatible. -15

16 1 Series Model and Dimensions (mm) Valve Dimensions Type Model No No Angle No No Horizontal angle No No No Straight No No * Available with nominal size 32A for angle and straight type. Sensor Model No Model No Wax type Model No (Capillary tube 2 m) Model No (Capillary tube 5 m) (Remote mounted type) Angle type Horizontal angle type Straight type At the Time of Order Select the valve and sensor in accordance with pipe installation and application. The valve and sensor are sold separately so please inform the requiring model number. -16

17 1 Series Flow Rate Chart KV value P: Pressure loss MPa Difference from set temperature Hot water flow rate is about 0 L/h, when ΔP = MPa and temperature decreased 2K (2 C) from set temperature. <Installing example> <Handling cautions> Do not install the sensor to valve during construction, since the valve and sensor are separated. Surely fix the sensor and valve after construction. Flush well the radiator and pipes in order to avoid scale problem inside the system. Please install the sensor at the place where precise temperature sensing is possible. The valve may not able to operate stably, if it is installed at the backward of curtain, furniture or radiator panel. Also when exposed to direct sunlight or draft. Install the sensor sideways. -17

18 Return Valve 109 Series Angle type Straight type Necessary for hot water controlled radiator heater. 109 series return valve Able to control the flow minutely. Specifications Application Maximum pressure Maximum temperature Body Material Valve Connection Cold and hot water 1.0 MPa 120 C Bronze or Brass (nickel plate) Brass Inlet: JIS Rp screwed Outlet: JIS R (union joint) Model and Dimensions (mm) Angle Straight Angle type Model No. Model No. Straight type -

19 109 Series Return Valve Flow Rate Chart Hot water flow rate (L/h) Flow rate at each rotation time 4rotation 3rotation 2rotation 1-rotation 1rotation rotation rotation How to adjust the flow rate 1. Remove the hexagon cap on the top and fully screw it clockwise by hexagon wrench (nominal 4). 2. Consider the heater capacity and operating pressure then decide the valve open level from the flow rate chart. 3. Twist the hexagon wrench counterclockwise for required rotation time and adjust the flow rate. 4. Attach the hexagon cap and tighten. 1/4rotation P: Pressure loss MPa The flow rate of chart is the reference value. Option/Service Tool Model No <Usage Example> Valve This tool can keep the valve installed even when removing the water from system. How to use is just remove the hexagon cap of return valve and connect with the tool. Able to drain water easily by twisting the handle. -19

20 MEMO -20

13-1. Temperature Regulator

13-1. Temperature Regulator -1 Step 0 Type/Structure/Features Please refer to this for type, structure and features of. Step 1 Selection Please look at the ID chart to choose the right products depending on the intended uses. Details

More information

Noiseless Heater Vacuum Relief Valve

Noiseless Heater Vacuum Relief Valve Noiseless Heater Vacuum Relief Valve -1 Step Type/Structure/Features Please refer to this for structure and feature of Noiseless Heater and Vacuum Relief valve. Step 1 Selection Please look at the ID chart

More information

Steam Trap. Assist Trap Radiator Trap Radiator Valve

Steam Trap. Assist Trap Radiator Trap Radiator Valve Assist Trap Raiator Trap Raiator Valve /Assist Trap Selection 0.3 0.5 0.7 1.0 150 160 170 220 231 232 231 233 TF-1 TFA-2000 TF-2 TB-5 1.0 2.0 4.2 183 220 425 228 228 229 229 227 227 226 TSD-7 TSD-7F TS-7

More information

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES FUNCTION Thermostatic expansion valves are used to regulate and cut-off the flow of the heat transfer fluid that circulates inside airconditioning system terminals (radiators, fan coils, etc.). Thermostat

More information

Disc Type Steam Trap TSD-42

Disc Type Steam Trap TSD-42 Disc Type TSD-42 TSD-42 is disc type steam trap for high pressure (maximum pressure: 4.2 MPa). It is compact and lightweight, and can be installed horizontally or vertically. Disc Ring By-Metal Valve seat

More information

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES FUNCTION Thermostatic expansion valves are used to regulate and cut-off the flow of the heat transfer fluid that circulates inside airconditioning system terminals (radiators, fan coils, etc.). Thermostat

More information

THERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE PRODUCTION RANGE IRON PIPE CODE CONNECTION

THERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE PRODUCTION RANGE IRON PIPE CODE CONNECTION THERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE CT0031.0_10 EN August 2016 THERMOSTATIC RADIATOR VALVES * * * * 028 * LICENSED USE OF TRADEMARK NR. 43 PRODUCTION RANGE IRON

More information

Thermostatic valves with radiator connection systems

Thermostatic valves with radiator connection systems Multilux Eclipse Thermostatic valves with radiator connection systems with two-point connection for two-pipe heating systems, with automatic flow limitation IMI HEIMEIER / Thermostatic heads and Radiator

More information

manifold, for radiators

manifold, for radiators MMA, for radiators Eco-friendly materials, low lead content Quiet Precise and linear Dimension: DN 0 Temperature: C to + C Pressure class: PN 0 Description Area of use The Evoflow radiator is especially

More information

Thermostatic Radiator Valves (Caleffi)

Thermostatic Radiator Valves (Caleffi) 02/09/16 B46 Thermostatic Radiator Valves (Caleffi) Thermostatic Control Heads Thermostatic control head fits radiator valves Set point locking mechanism Range stop adjustment Built-in sensor with liquid-filled

More information

Vacuum Saving Valve. ZP2V Series. With One-touch fitting type available!

Vacuum Saving Valve. ZP2V Series. With One-touch fitting type available! Vacuum Saving Valve Series Can restrict the reduction of vacuum pressure even when there is no workpiece. When multiple vacuum pads are operated by one vacuum generator, and some of them are not holding

More information

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems E-Z Valve Thermostatic valves with radiator connection systems For single and two-pipe heating systems IMI HEIMEIER / Thermostatic heads and Radiator valves / E-Z Valve E-Z Valve E-Z Valve with immersion

More information

Radiator Valve Program

Radiator Valve Program Radiator Valve Program Heat seeks cold faster when the temperature difference is greater. Lowering the temperature of a room reduces the amount of heat leaving the room (heat loss). Installing thermostats

More information

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT Technical Data SD 4511A SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY 12586-2035 TYPE T14 & T14D TEMPERATURE PILOT PRINTED IN U.S.A. SD 4511A/9811 5 13 /16 D 4 7 /8 1 13 /16 T14 PILOT

More information

teide termo plus+ HEATING SERIES SCOPE THERMOSTATIC VALVES SERVICE CONDITIONS COMPONENTS TECHNICAL SHEET 07/2017 IP20060 PAG. 1/9

teide termo plus+ HEATING SERIES SCOPE THERMOSTATIC VALVES SERVICE CONDITIONS COMPONENTS TECHNICAL SHEET 07/2017 IP20060 PAG. 1/9 HEATING SERIES QUALITY BY TRADITION teide termo plus+ TECHNICAL SHEET 07/2017 IP20060 SCOPE The thermostatic valves and heads from TEIDE TERMO PLUS series can be used in individual or collective heating

More information

THERMOSTATIC SINGLE-PIPE AND DOUBLE-PIPE VALVES

THERMOSTATIC SINGLE-PIPE AND DOUBLE-PIPE VALVES ST.07.05.00 THERMOSTIC SINGLE-PIPE AND DOUBLE-PIPE VALVES 1. Art.1420 THERMOSTIC SINGLE-PIPE VALVE Single-pipe valves allow manual, thermostatic or thermo-electric regulation. Separation of the lockshield

More information

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting For reversed flow direction Thermostatic Radiator Valves Thermostatic valve body with and without presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / For reversed flow direction For reversed

More information

Multilux 4-Eclipse-Set

Multilux 4-Eclipse-Set Multilux -Eclipse-Set Design-Edition with two-point connection, angle and straight type, for R / and connection, with automatic flow limitation IMI HEIMEIER / Design-Edition / Multilux -Eclipse-Set Multilux

More information

INSTALLATION, OPERATION

INSTALLATION, OPERATION OM No. E-SCSF-170111-1 INSTALLATION, OPERATION and MAINTENANCE MANUAL Thermodynamic Steam Trap MODEL: SC/SF MIYAWAKI INC. Osaka, Japan 2 SAFETY INSTRUCTION Prior to using the SC/SF steam trap, read this

More information

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation Standard Sheet for 6823/ 6824 Edition 1000 (0999) 6823 6824 Special Models 1

More information

Mikrotherm. Manual Radiator Valves With presetting

Mikrotherm. Manual Radiator Valves With presetting Mikrotherm Manual Radiator Valves With presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Mikrotherm Mikrotherm The Mikrotherm manual radiator valve is used in warm water pump heating systems,

More information

Control valves for floor heating systems. Floor Heating Manifolds

Control valves for floor heating systems. Floor Heating Manifolds Control valves for floor heating systems Floor Heating Manifolds IMI HEIMEIER / Floor Heating Control / Control valves for floor heating systems Control valves for floor heating systems Supply control

More information

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation Standard C Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Standard C Standard C The Standard C thermostatic

More information

RA2000 Thermostatic Radiator Valves

RA2000 Thermostatic Radiator Valves Data Sheet RA2000 Thermostatic Radiator Valves Application regulate the flow of hot water or steam through free-standing radiators, baseboards or convectors in hot water and two-pipe low pressure steam

More information

HERZ TS-3000 HERZ HERZ Armaturen A-1230 Vienna Richard-Strauss-Straße 22

HERZ TS-3000 HERZ HERZ Armaturen A-1230 Vienna Richard-Strauss-Straße 22 HERZ TS-3000 HERZ-3000 Connection system for radiators Thermostatic valve and shut-off return valve Standard sheet for 3691-3694 3791 3794 Issue 0702 G 3/4 Dimensions in mm 1 3002 31 Connection nipples

More information

Thermostatic Actuators

Thermostatic Actuators 2 111 EN 215-1 RTN51.. with remote sensor RTN81 with remote adjuster ACVATIX TM Thermostatic Actuators for radiator valves VDN.., VEN.., VUN.., VPD.. and VPE.. RTN51.. RTN81 Self-acting, without auxiliary

More information

RA15/6T & TB Conversion Valve

RA15/6T & TB Conversion Valve Applications: continue on. This provides continuous flow, but inherent to series piping the supply water temperature will decrease as it flows through the system and when it mixes with return water from

More information

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 The XB is a brazed plate heat exchanger designed for use with district heating systems (i.e. air conditioning,

More information

HERZ Regulating valve 4002

HERZ Regulating valve 4002 HERZ Regulating valve 4002 Data sheet 4002, Issue 0214 Dimensions in mm B1 B2 1 4002 41 1 4002 61 1 4002 42 1 4002 62 1 4002 43 1 4002 63 1 4002 44 1 4002 64 1 4002 45 1 4002 65 1 4002 46 1 4002 66 DN

More information

HERZ Differential Pressure Control Valve 4002

HERZ Differential Pressure Control Valve 4002 HERZ Differential Pressure Control Valve 4002 Data sheet 4002, Issue 0118 Dimensions in mm B1 B2 1 4002 41 1 4002 61 1 4002 71 1 4002 42 1 4002 62 1 4002 72 1 4002 43 1 4002 63 1 4002 73 1 4002 44 1 4002

More information

Thermostatic valve bodies

Thermostatic valve bodies Thermostatic valve bodies for single pipe heating systems Thermostatic valves with radiator connection systems IMI HEIMEIER / Thermostatic heads and Radiator valves / Thermostatic valve bodies for single

More information

Systems for central heating

Systems for central heating www.far.eu Highlight Systems and Components for central heating Components for renewable energy systems Pressfar Fittings Presetting valves and thermostatic head Balancing devices Zone valves Metering

More information

Residential Flat Concealed Sprinkler, Pendent, Model: CN-RES, K-Factor: 4.9, SIN: SS8421

Residential Flat Concealed Sprinkler, Pendent, Model: CN-RES, K-Factor: 4.9, SIN: SS8421 Page:1 of 7 Residential Flat Concealed Sprinkler, Pendent, Model: CN-RES, K-Factor: 4.9, SIN: SS8421 GENERAL DESCRIPTION The Model CN-RES Residential Flat Concealed Sprinklers are automatic sprinklers

More information

Eclipse F. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

Eclipse F. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation Eclipse F Adaptative Flow Control Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Eclipse F Eclipse F The thermostatic

More information

4-way valve with thermostatic option with variable centre distance and pre-adjustment for Single pipe and Dual pipe systems.

4-way valve with thermostatic option with variable centre distance and pre-adjustment for Single pipe and Dual pipe systems. 4-way valve with thermostatic option with variable centre distance and pre-adjustment for Single pipe and Dual pipe systems. CT3101.0_00 EN June 2016 o o o o Valve with pre-adjustment; Variable centre

More information

Automatic balancing valves ASV-PV (new generation) DN 32-50

Automatic balancing valves ASV-PV (new generation) DN 32-50 Automatic balancing valves ASV-PV (new generation) DN 32-50 ASV-PV DN 32-50 Description ASV whiteboard animation SMT/SI ASV valves are automatic balancing valves. Together with Danfoss presetting radiator

More information

Flush individual room control for floor heating systems

Flush individual room control for floor heating systems Multibox Flush individual room control for floor heating systems Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGiNEERiNG ADVANTAGE Multibox is used for decentralized control

More information

Series 1140 and 1141 Temperature Regulators

Series 1140 and 1141 Temperature Regulators Hoffman Specialty Installation & Maintenance Instructions HS-504(E) Series 1140 and 1141 Temperature Regulators! CAUTION FOLLOW ALL INSTALLATION AND OPERATING INSTRUCTIONS. TURN OFF WATER OR STEAM BEFORE

More information

Eclipse. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

Eclipse. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation Eclipse Adaptative Flow Control Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Eclipse Eclipse The thermostatic

More information

Thermostatic head K. with contact or immersion sensor. Thermostat-Köpfe For medium temperature control

Thermostatic head K. with contact or immersion sensor. Thermostat-Köpfe For medium temperature control Thermostatic head K with contact or immersion sensor Thermostat-Köpfe For medium temperature control IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Thermostatic head K with contact or immersion

More information

Multibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off

Multibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off Multibox 4 Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off IMI HEIMEIER / Floor Heating Control / Multibox 4 Multibox 4 RTL and K-RTL and K-RTL is

More information

TRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield

TRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield TRV pack Eclipse Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield IMI HEIMEIER / Thermostatic heads and Radiator valves /

More information

Thermostatic head with wax sensor

Thermostatic head with wax sensor Combined with valves covered by EN215 01 november 2004 ı Technical communication n da Use In modern society research concerning comfort in the home becomes a factor of prime importance. In order to obtain

More information

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Data sheet Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 IHPT The XB is a brazed plate heat exchanger designed for use with district heating systems

More information

Multibox. Floor Heating Controller Flush individual room control for floor heating systems

Multibox. Floor Heating Controller Flush individual room control for floor heating systems Multibox Floor Heating Controller Flush individual room control for floor heating systems IMI HEIMEIER / Floor Heating Control / Multibox Multibox K, RTL and K-RTL Multibox K, RTL and K-RTL is used for

More information

CALIS-TS-3-D. HERZ Armaturen. Standard Sheet for 7745, 7746, 7761 Edition 0700 (0999) Three-Way Valves in 3-D Design for One-Pipe Systems

CALIS-TS-3-D. HERZ Armaturen. Standard Sheet for 7745, 7746, 7761 Edition 0700 (0999) Three-Way Valves in 3-D Design for One-Pipe Systems -3-D Three-Way Valves in 3-D Design for One-Pipe Systems Standard Sheet for 7745, 7746, 7761 Edition 0700 (0999) Dimensions in mm 7761 C H -E 7745 7746 C H H = Height HEZ-thermostat 37,5 Ø Flow-T-Piece

More information

V-exact II. Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting

V-exact II. Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting V-exact II Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / V-exact II V-exact II V-exact II thermostatic valve

More information

Regulux. Return Lockshield Radiator lockshield with consistent presetting and drain-off facility

Regulux. Return Lockshield Radiator lockshield with consistent presetting and drain-off facility Regulux Return Lockshield Radiator lockshield with consistent presetting and drain-off facility IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Regulux Regulux The Regulux is used in warm water pump

More information

WAL-RICH CORPORATION SINCE 1950

WAL-RICH CORPORATION SINCE 1950 STEAM SPECIALTIES ANGLE STEAM RADIATOR VALVES 0408102 1/2 1 10 0408104 3/4 1 6 0408002 1" 1 4 0408004 1 1/4" 1 2 0408006 1 1/2 1 2 - Brass - Imported STRAIGHT STEAM RADIATOR GATE VALVES 0409002 1" 1 4

More information

Calypso TRV-3. (for the Nordic countries) Thermostatic radiator valves With presetting

Calypso TRV-3. (for the Nordic countries) Thermostatic radiator valves With presetting Calypso TRV-3 (for the Nordic countries) Thermostatic radiator valves With presetting IMI TA / Thermostatic heads and Radiator valves / Calypso TRV-3 (for the Nordic countries) Calypso TRV-3 (for the Nordic

More information

Standard. thermostatic valve body without presetting

Standard. thermostatic valve body without presetting Standard thermostatic valve body without presetting Pressurisation & Water Quality Balancing & Control Thermostatic Control EnGInEErInG advantage The standard thermostatic valve bodies are used in two-pipe

More information

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge Regulux Description Separate presetting cone for consistent

More information

Hollow Fiber Membrane Filter Type Air Dryer with Built-in Push-In Fitting

Hollow Fiber Membrane Filter Type Air Dryer with Built-in Push-In Fitting http://www.pisco.co.jp PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Hollow Fiber Membrane Filter Type Air Dryer with Built-in Push-In Fitting Fiber Dry Series 188 Hollow Fiber Membrane Filter Type

More information

INSTALLATION, OPERATION

INSTALLATION, OPERATION OM No. E-ER25-230627 en INSTALLATION, OPERATION and MAINTENANCE MANUAL Inverted Bucket Steam Trap MODEL: ER 25 SERIES MIYAWAKI INC. Osaka, Japan Headquarter: MIYAWAKI Inc. 2-1-30, Tagawakita, Yodogawa-ku

More information

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting Calypso exact Thermostatic Radiator Valves With stepless precision presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Calypso exact Calypso exact Calypso exact thermostatic valve bodies are

More information

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Data sheet Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 IHPT The XB is a brazed plate heat exchanger designed for use with district heating systems

More information

Semi-Automatic Suction Screen Filters 3"-4 Angle. Service & Maintenance Manual

Semi-Automatic Suction Screen Filters 3-4 Angle. Service & Maintenance Manual Semi-Automatic Suction Screen Filters 3"-4 Angle Service & Maintenance Manual Safety Instructions Prior to installation or handling of the filter, read the Installation and Operation instructions carefully.

More information

In the event of this condition, consult the Authorities Having Jurisdiction for guidance and approval.

In the event of this condition, consult the Authorities Having Jurisdiction for guidance and approval. General Description Data Sheet 4.20 Commercial Flat Concealed Sprinkler, Pendent Quick Response, Standard Coverage Model: RD107 (RD-CN-QR EU) K=80 The Model RD107 Commercial Flat Concealed Sprinklers are

More information

Temperature controller for steam (PN 25) AVT / VGS - external thread

Temperature controller for steam (PN 25) AVT / VGS - external thread Data sheet Temperature controller for steam (PN 25) AVT / VGS - external thread Description The controller has a control valve VGS, thermostatic actuator and handle for temperature setting. Thermostatic

More information

Commercial Flat Concealed Sprinkler, Pendent, Quick & Standard Response, Standard Coverage, Model: CN-QR, K-Factor: 5.

Commercial Flat Concealed Sprinkler, Pendent, Quick & Standard Response, Standard Coverage, Model: CN-QR, K-Factor: 5. Page:1 of 6 Commercial Flat Concealed Sprinkler, Pendent, Quick & Standard Response, Standard Coverage, Model: CN-QR, K-Factor: 5.6, SIN: SS9521 GENERAL DESCRIPTION The Model CN-QR Commercial Flat Concealed

More information

UNIT 5 COOLING SYSTEMS OF IC ENGINES

UNIT 5 COOLING SYSTEMS OF IC ENGINES UNIT 5 COOLING SYSTEMS OF IC ENGINES Cooling Systems of IC Engines Structure 5.1 Introduction Objectives 5.2 Air Cooling System 5.3 Water Cooling System 5.3.1 Components of Water Cooling System 5.3.2 Advantages

More information

Vekotrim. Valves for radiators with integrated valve Double connection fitting with shut-off ball valves for radiators with integrated valves

Vekotrim. Valves for radiators with integrated valve Double connection fitting with shut-off ball valves for radiators with integrated valves Vekotrim Valves for radiators with integrated valve Double connection fitting with shutoff ball valves for radiators with IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Vekotrim Vekotrim The Vekotrim

More information

Radiator valve inserts

Radiator valve inserts Radiator valve inserts Valve insert cartridge The heart of the Oventrop radiator valve is the insert. All the working functions of the valve have been incorporated into a removable cartridge. This cartridge

More information

Design-Edition. Design-Edition Thermostatic valves and lockshields, sets

Design-Edition. Design-Edition Thermostatic valves and lockshields, sets Design-Edition Design-Edition Thermostatic valves and lockshields, sets IMI HEIMEIER / Design-Edition / Design-Edition Design-Edition The sets are an elegant solution for e. g. design radiators. A sublime

More information

THERMODYNAMIC STEAM TRAP

THERMODYNAMIC STEAM TRAP THERMODYNAMIC STEAM TRAP Model 041 Model 043 041 043 For the extraction of steam condensates. For use in: steam piping, irons, laundries, tanks and vessels with condensate discharge, multiple plate presses,

More information

Akva Vita TDP District heating flat station for direct heating and domestic hot water systems

Akva Vita TDP District heating flat station for direct heating and domestic hot water systems Akva Vita TDP District heating flat station for direct heating and domestic hot water systems Akva Vita TDP Table of contents Akva Vita TDP... 1 Table of contents... 1 Safety notes... 2 Delivery... 2 Transport

More information

VENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133.

VENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133. Main Steam How to Select Steam For Steam Vent selection information, please refer to Selection Guidelines on page 133. Model Radiator Convector Unit Thermostatlic Number (Angle Type) (Bottom Inlet) Heater

More information

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Hot Water Tempered Water Outlet Cold Water Tempered Water Outlet Redundant Thermostatic Mixing Valve Hot Water

More information

Convertible radiator valve for one-pipe systems, centre distance 35 mm

Convertible radiator valve for one-pipe systems, centre distance 35 mm Convertible radiator valve for one-pipe systems, centre distance 35 mm 56 series ACCREDITED ISO 900 FM 65 033/6 GB Function 56 series convertible radiator valves are used on one-pipe radiator systems.

More information

SENJU SPRINKLER CO.,LTD. Residential Flush Pendent Sprinkler Model ZN-RES,K=4.2 (SIN / SS4421) (PTFE gasketed orifice seal design) General Description

SENJU SPRINKLER CO.,LTD. Residential Flush Pendent Sprinkler Model ZN-RES,K=4.2 (SIN / SS4421) (PTFE gasketed orifice seal design) General Description Page:1 of 5 SENJU SPRINKLER CO.,LTD. Residential Flush Pendent Sprinkler Model ZN-RES,K=4.2 (SIN / SS4421) (PTFE gasketed orifice seal design) General Description The Model ZN-RES Residential Flush Pendent

More information

Inverted bucket steam traps Type OKZ PN6/PN16

Inverted bucket steam traps Type OKZ PN6/PN16 -TERMOENERGETIKA- Inverted bucket steam traps Type OKZ PN6/PN16 We produce the inverted bucket steam traps type OKZ for nominal pressures PN 6 and PN 16 These traps have automatic air vent on the start-up.

More information

High Capacity Instantaneous Steam Fired Water Heater

High Capacity Instantaneous Steam Fired Water Heater MODEL F High Capacity Instantaneous Steam Fired Water Heater Features Compact High Capacity Design Packaged System Water heater is factory assembled on an all welded steel mounting frame to save time and

More information

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Reduced Installation time Precision regulation Minimal tooling required 100% tested prior to packaging High quality

More information

Straight pattern thermostatic radiator valve vertical or horizontal mounting with (368T CPDLS) matching drain off lockshield

Straight pattern thermostatic radiator valve vertical or horizontal mounting with (368T CPDLS) matching drain off lockshield Straight pattern thermostatic radiator valve vertical or horizontal mounting with (368T CPDLS) matching drain off lockshield Straight pattern TRV & drain off lockshield pack Size Pattern No. Pack 1 Qty

More information

Multibox. Flush Individual Room Control for Floor Heating Systems. To be precise.

Multibox. Flush Individual Room Control for Floor Heating Systems. To be precise. Flush Individual Room Control for Floor Heating Systems To be precise. Contents Page Multibox K, Multibox RTL and Multibox K-RTL Description Construction Application 4 Temperature Setting 4 Function Article

More information

Data Sheet 4.19 Issue C

Data Sheet 4.19 Issue C General Description The Model RD05 Commercial Flat Concealed Sprinklers are automatic sprinklers of the compressed fusible solder type. These are decorative and quick/standard response. The frame of the

More information

TRV & Lockshield Pack Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting with (367 CPLS) matching lockshield

TRV & Lockshield Pack Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting with (367 CPLS) matching lockshield TRV & Lockshield Pack Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting with (367 CPLS) matching lockshield GENERAL INFORMATION Size Pattern No. Pack 1 Qty Code Barcode Angle Pattern

More information

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Catalog. Self-operated Regulators Volume 2 Temperature Regulators Catalog Self-operated Regulators Volume 2 Temperature Regulators Self-operated Regulators Temperature Regulators Volume 2 Catalog 2012 Overview Self-operated Temperature Regulators 5 Self-operated Pressure

More information

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting Standard Thermostatic Radiator Valves Thermostatic valve body without presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Standard Standard The Standard thermostatic valve bodies are used

More information

Instructions. Certifications Brass w/built-in Stop Valve. Pressure Balance Shower Valve. Tools Required. Important Points.

Instructions. Certifications Brass w/built-in Stop Valve. Pressure Balance Shower Valve. Tools Required. Important Points. Instructions Tools Required Adjustable Wrench Groove Joint Pliers Pipe Wrench Phillips Screwdriver Pipe Tape or Pipe Thread Compound Safety Tips If you solder the joints during installation, the seats,

More information

GENERAL CATALOGUE MICROMETRIC, THERMOSTATIC VALVES THERMOSTATIC VALVES MANUAL VALVES LOCKSHIELDS ACCESSORIES AND SPARE PARTS

GENERAL CATALOGUE MICROMETRIC, THERMOSTATIC VALVES THERMOSTATIC VALVES MANUAL VALVES LOCKSHIELDS ACCESSORIES AND SPARE PARTS GENERAL CATALOGUE MICROMETRIC, TERMOSTATIC VALVES TERMOSTATIC VALVES MANUAL VALVES LOCKSIELDS ACCESSORIES AND SPARE PARTS SUMMARY 1. USE 2. MICROMETRIC TERMOSTATIC VALVES 3. TECNICAL DATA 3. MATERIALS

More information

Thermostatic valve bodies

Thermostatic valve bodies Thermostatic valve bodies for all thermostatic heads and actuators Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING ADVANTAGE ThermosTaTic valve bodies Table of contents

More information

caleffi hydronic valves page 1 of 12

caleffi hydronic valves page 1 of 12 caleffi hydronic valves page 1 of 12 page 2 of 12 MANUAL RADIATOR VALVES 1601811 - Series 340 1601812 - Series 341 1603748 - Seies 411 1603749 - Series 412 CONVERTIBLE RADIATOR VALVES 1601816 - Series

More information

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference TEMPERATURE CONTROL STEAM TRAP LEX3N-TZ LEX3N-TZ.

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference TEMPERATURE CONTROL STEAM TRAP LEX3N-TZ LEX3N-TZ. INSTRUCTION MANUAL Keep this manual in a safe place for future reference TEMPERATURE CONTROL STEAM TRAP LEX3N-TZ LEX3N-TZ Manufacturer 881 Nagasuna, Noguchi, Kakogawa, Hyogo 675-8511, Japan Tel: [81]-(0)79-422-1122

More information

Commercial Flat Concealed Sprinkler, Pendent, Quick Response, Standard Coverage, Model: RC-QR, K-Factor: 5.6, SIN: SS9561

Commercial Flat Concealed Sprinkler, Pendent, Quick Response, Standard Coverage, Model: RC-QR, K-Factor: 5.6, SIN: SS9561 Page:1 of 7 Commercial Flat Concealed Sprinkler, Pendent, Quick Response, Standard Coverage, Model: RC-QR, K-Factor: 5.6, SIN: SS9561 GENERAL DESCRIPTION The Model RC-QR Commercial Flat Concealed Sprinklers

More information

thermostatic valve body with stepless precision presetting

thermostatic valve body with stepless precision presetting Thermostatic Radiator Valves V-exact II thermostatic valve body with stepless precision presetting Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING AVANTAGE V-exact II

More information

Main Steam Vents. Hoffman Specialty Regulators. How to Select Steam Vents

Main Steam Vents. Hoffman Specialty Regulators. How to Select Steam Vents Hoffman Specialty Regulators Main Steam How to Select Steam Model Radiator Convector Unit Thermostatlic Number (Angle Type) (Bottom Inlet) Heater Mains Vent (only) Remarks 1A X Adjustable Orifice 70A X

More information

Thermostatic mixing valves with interchangeable cartridges

Thermostatic mixing valves with interchangeable cartridges www.caleffi.com R37. Thermostatic mixing valves with interchangeable cartridges Installation, commissioning and servicing instructions 3 Series Function The thermostatic mixing valve is used in systems

More information

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25) Data sheet Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25) Description STW871 The controllers are: - Type-tested acc. to EN 14597 and protect against exceeding temperatures:

More information

Zip Econoboil. On wall boiling water. Installation instructions & user manual. Model number: ,

Zip Econoboil. On wall boiling water. Installation instructions & user manual. Model number: , Zip Econoboil On wall boiling water. Model number: 305542, 303542 1 Table of contents Intended Use... 2 Warnings and precautions... 3 Before installation... 5 Technical specification... 6 Installation

More information

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting Standard Thermostatic Radiator Valves Thermostatic valve body without presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Standard Standard The Standard thermostatic valve bodies are used

More information

RA 2000 Series RA 15/6T & TB Conversion Valve

RA 2000 Series RA 15/6T & TB Conversion Valve RA 2000 Series RA 15/6T & TB Conversion Valve Applications: RA15/6T Internal bypass allowing for series piping to the radiators/baseboards. This series piping provides continuous flow but the supply water

More information

PRODUCTS. Expansion Joints Fire Fighting. Flexible Metal Hoses. Equipments. Insulation Solutions. Steam. Valves. Level Control.

PRODUCTS. Expansion Joints Fire Fighting. Flexible Metal Hoses. Equipments. Insulation Solutions. Steam. Valves. Level Control. PRODUCTS Expansion Joints Fire Fighting Equipments Flexible Metal Hoses Steam Equipments Valves Level Control Insulation Solutions VALVES FLEXIBLE METAL HOSES EXPANSION JOINTS LEVEL CONTROL EQUIPMENTS

More information

Reducing Valve Direct Mount Type with Pressure Gauge. Direct Mount Type (Compact size) Pressure Gauge is selectable.

Reducing Valve Direct Mount Type with Pressure Gauge. Direct Mount Type (Compact size) Pressure Gauge is selectable. http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Reducing Valve Direct Mount Type with Pressure Gauge 232 Direct Mount Type (Compact size) Pressure Gauge is selectable. Display

More information

Akva Vita TDP-F District heating flat station for direct heating and domestic hot water systems

Akva Vita TDP-F District heating flat station for direct heating and domestic hot water systems Akva Vita TDP-F District heating flat station for direct heating and domestic hot water systems Akva Vita TDP-F Table of contents Akva Vita TDP-F...1 Table of contents...1 Safety notes...2 Delivery...2

More information

Akva Vita Instantaneous water heater

Akva Vita Instantaneous water heater Akva Vita Instantaneous water heater Akva Vita Table of Contents Akva Vita... 1 Table of Contents... 1 Safety notes... 2 Delivery... 2 Transport and storage... 2 Mounting... 3 Pipes connections... 4 Electrical

More information

Data Sheet 4.16 Issue D

Data Sheet 4.16 Issue D General Description The Model RD205 Residential Flat Concealed Sprinklers are automatic sprinklers of the compressed fusible solder type. These are decorative and fast response. The frame of the sprinkler

More information

Residential Flush Horizontal Side-Wall Sprinkler Model HF-RES,K=4.2 (SIN / SS4423) (PTFE gasketed orifice seal design)

Residential Flush Horizontal Side-Wall Sprinkler Model HF-RES,K=4.2 (SIN / SS4423) (PTFE gasketed orifice seal design) Page:1 of 5 Residential Flush Horizontal Side-Wall Sprinkler Model HF-RES,K=4.2 (SIN / SS4423) (PTFE gasketed orifice seal design) General Description The Model HF-RES Residential Flush Horizontal Side-Wall

More information

Solar heating systems

Solar heating systems 03 energy efficiency Compact, "ALL-IN-ONE" solar system Solar panel for swimming pools Hydraulic components Drain-Unit: dual hydraulic unit with drain back system Drain-Unit: hydraulic unit with drain-back

More information

Membrane Air Dryer. Dew point indicator. Fitting to exhaust purge air for dew point checker. Purge air discharge fitting for dehumidification

Membrane Air Dryer. Dew point indicator. Fitting to exhaust purge air for dew point checker. Purge air discharge fitting for dehumidification Membrane Air Dryer Series IDG Dew point indicator Dew point indicator visually confirms air drying (Except IDG) (Optional on IDG3, IDG5, IDG3H, IDG5H) Compact Lightweight Space-saving Type with fitting

More information