ECO ROOF FAN. A modern, energy-saving roof fan with a DC motor. INSTALLER Register the roof fan for an extended 5 year guarantee!
|
|
- Norah Benson
- 5 years ago
- Views:
Transcription
1 ECO ROOF FAN A modern, energy-saving roof fan with a DC motor INSTALLER Register the roof fan for an extended 5 year guarantee! Download VILPE app for Android or ios and fill in the information. Further information: BEFORE INSTALLATION, REMOVE LABEL
2 VILPE makes fan selection easy! Today, ventilation comes as a matter of course, but not without a cost of money and energy. VILPE product family is a complete system of ventilation and roofing products for providing fresh air for your domestic enviornments easily, securely and energy efficiently. VILPE ECo roof fans are the result of a long product development and advanced design. They offer a unique flow characteristics, maximum efficiency and extremely low SFP. This, combined with easy installation and the best warranty terms makes VILPE into the easiest choice for your ventilation needs. VILPE solutions are installed easily and securely on any roofing materials and profiles on the market. Learn more about how simple and cost effective ventilation can be Manufacturing materials VILPE ECo roof fans are manufactured from corrosion, weather and impact resistant, recyclable, UV protected and solid coloured polypropene (PP). PP is chemically neutral and harmless to the environment. VILPE -standard colours Air flow, all VILPE roof fans Black Reference colour RAL 917 (de 1,17) Brown Reference colour RAL 817 (de 2,33) Green Reference colour RAL 62 (de 1,91) Grey Reference colour RAL 715 (de 2.11) Red Reference colour RAL 9 (de 4.92) Brick red Reference colour RAL 84 (de 2.8) Light grey Reference colour RAL 74 (de,54) m 3 /h ) E12 Ø 125 mm 5 2 ) E19 Ø 125 mm 3 ) E ) Ø 16 mm ECo11 Ø 11 mm 6 5 ) ECo19 4 Ø 125 mm 6 ) ECo22 Ø 16 mm 3 7 ) ECo2XL 3 Ø mm Ilman Air flow tilavuusvirta rate, l/secdm /s
3 VILPE ECo roof fans VILPE ECo series roof fans are effectively controlled roof fans with a DC motor. The motor has better efficiency and optimised control, so the ECo roof fan consumes much less energy than a roof fan with an AC motor. Applications VILPE ECo roof fans with a DC motor are used in kitchen or bathroom exhaust ventilation as part of the air conditioning systems of new apartment buildings and private and terraced houses. When refurbishing older apartment buildings and private and terraced houses, natural ventilation can be converted to mechanical by means of the VILPE ECo roof fan. VILPE ECo roof fans are used for the ventilation of homes, offices, commercial premises, production facilities, public buildings and any other areas where fresh air is needed. In apartment buildings, ECo roof fans can be used for exhaust ventilation in lift shafts and other public areas. VILPE ECo is also used for base floor ventilation, radon exhaust ventilation, and exhaust ventilation in garages and storerooms. Fresh air indoors A roof fan will remove dirty, stuffy, humid and dusty air plus unpleasant smells from indoor areas. It will also protect the structures of the building and any property stored there from humidity and impurities. Unrivalled ECo series Control with a 1 V voltage message helps integration with building technology systems Unlike previous VILPE roof fan solutions, VILPE ECo fans can be provided with stepless remote control, which uses a standard 1 V voltage message. An ECo roof fan can also provide an output signal which can be used to monitor the motor s rpm. This allows connecting ECo roof fans to an automatically controlled building technology system where they can be monitored and controlled with the system s CPU. ECo 11 series models can be used to exhaust radon or to ventilate an ecological toilet. The rpm of their motors is controlled by a potentiometer located in a link box on the roof, in the cowl of the roof fan. DC motor saves energy. The fan in VILPE ECo roof fans is based on the EC technology, which means that it is an electronically commuted fan with a brushless DC motor. ECo roof fans address the challenge of reducing total energy consumption by saving energy, as the DC motor is much more effective than an AC motor. Calculations on the efficiency needed to move air show that a VILPE ECo roof fan will save up to 4 6% of energy when compared to an AC roof fan, depending on the application. ECo roof fans meet future requirements VILPE ECo conform to the requirements given in the following EU directives: energy label (EU) 1254/214, ecodesign (EU) 1253/214, ecodesign (EU) 327/211, Electromagnetic Compatibility (EMC) Directive 214/3/EU, The Low Voltage Directive (LVD) 214/35/EU 214/35/EU, RoHS directive 2/95/EC, WEEE directive 2/96/EC.
4 ECo19, ECo22 ECo19P Duct size ø 125 mm To be installed on the roof with a VILPE roof pass-through suited for the roof type Due to its mm insulation, the pipe doubles as a sound absorber The inner pipe is made from galvanized sheet metal and has a lip seal ECo19S Duct size ø 125 mm To be installed on a flat surface either on a pipe with external ø 16 mm or directly on the surface with the included x mm installation set ECo Monitor ECo22P ECo Monitor can be used to monitor and control up to five ECo19, ECo22 and ECo2 XL roof fans. Duct size ø 16 mm To be installed on the roof with a VILPE roof pass-through suited for the roof type The inner pipe is made from galvanized sheet metal and has a lip seal ECo Controller - 1 V ECo22S ECo19, ECo22 and ECo2 XL roof fans can be controlled with an ECo motor controller, 1 V Duct size ø 16 mm To be installed on a flat surface either on a pipe with external ø 225 mm or directly on the surface with the included x mm installation set ECo11 ECo2 XL ECo2 XL models are especially suitable for use in large properties, such as apartment buildings, office buildings, halls and warehouses. VILPE ECo roof fans can be used as part of the ventilation system or for local extraction in the elevator shafts and other public facilities. In residential houses they are used for kitchen exhaust ventilation in combination with a cooker hood. ECo11 can be used to exhaust radon or to ventilate an ecological toilet. A potentiometer controls the rpm of the fan motor. It is installed in a link box on the roof, in the cowl of the roof fan. The potentiometer will be adjusted based on measurements taken indoors. ECo2P XL Duct size ø mm To be installed on the roof with a VILPE roof XL pass-through suited for the roof type The inner pipe is made from galvanized sheet metal and has a lip seal ECo2S XL Duct size ø mm To be installed on a flat surface either on a pipe with external ø 35 mm or directly on the surface with the included x mm installation set ECo11P Duct size ø 11 mm To be installed on the roof with a VILPE roof pass-through suited for the roof type ECo11S Duct size ø 11 mm To be installed on a flat surface either on a pipe with external ø 16 mm or directly on the surface with the included 2 x 2 mm installation set ECo11C Duct size ø 11 mm To be installed inside a sheet steel cone manufactured by a tin smith with Ø 17 mm at the top Electrical specifications Fan type Rated power Rated current Voltage Speed Rpm control ECo11 83 W,75 A 2/ Hz 3 rpm Potentiometer installed in a link box in the cowl of the roof fan ECo19 83 W,75 A 2/ Hz 3 rpm 1 V signal or PWM ECo22 85 W,7 A 2/ Hz 258 rpm 1 V signal or PWM ECo2 XL 165 W 1,4 A 2/ HZ 256 rpm 1 V signal or PWM
5 Flow performance values ISO 581:8, connection type C Air density 1,2 kg/m3 Electric power ISO 581:8, connection type C Air density 1,2 kg/m3 ECo11 Ø 11 mm m³/h Ilman tiheys on 1,2 kg/m 1 V V Ilman tilavuusvirta, dm /s Air flow rate, l/sec Power consumed by the roof fan, W m³/h V 1 V Ilman Air flow tilavuusvirta, rate, l/sec dm 3 /s ECo19 Ø 125 mm m³/h Jännite Voltage 1 V 1 V Ilman Air flow tilavuusvirta, rate, l/secdm 3 /s Power consumed by the roof fan, W m³/h V 1 V Air flow rate, l/sec Ilman tilavuusvirta, dm /s ECo22 Ø 16 mm m³/h Ilman tiheys on 1,2 kg/m V V 2 Ilman Air flow tilavuusvirta, rate, l/secdm /s Power consumed by the roof fan, W m³/h Jännite Voltage V 1 V Air flow rate, l/sec Ilman tilavuusvirta, dm /s ECo2 XL Ø mm m³/h Ilman tiheys on 1,2 kg/m V 1 V Power consumed by the roof fan, W m³/h V 16 1 V Ilman Air flow tilavuusvirta, rate, l/secdm 3 /s Air flow rate, l/sec
6 VILPE ECo Ideal Wireless What is demand-controlled ventilation? Demand controlled ventilation is a smart system to maintain air quality in the desired level automatically, without human interference during the operation. The system automatically adjusts the required ventilation according to the prevailing air quality. Wireless sensors measure the relative humidity (RH) and carbon dioxide (CO2) levels in the air and send this information wirelessly to the control unit. The level of ventilation is then adjusted to secure good air quality without using excess energy. Why choose the VILPE ECo Ideal Wireless for demand-controlled ventilation? The VILPE ECo Ideal Wireless offers a cost-efficient solution with a short payback time compared to more complex ventilation solutions. The overall cost of the VILPE ECo Ideal Wireless is up to 7 per cent lower than the cost of a complete heat recovery (HVAC) installation. VILPE ECo Ideal Wireless is quick and easy to retrofit. The wireless communication solution minimises the need for wiring. If there are ducts already in place, the installation doesn t require building new ducts, i.e. all existing structures can remain as they are. Existing ducting or ventilation chimneys can also be utilised. Usage: Renovation sites and new buildings Whether you are renovating or building from scratch, the demand-controlled and energy-saving VILPE ECo Ideal Wireless is an excellent choice for an easy and budget-friendly implementation for your ventilation needs. VILPE ECo Ideal Wireless system is an ideal solution if you wish to convert an existing natural ventilation system to a mechanical ventilation system. VILPE ECo Ideal Wireless is also an easy and affordable way to turn a mechanical ventilation system into a demand-controlled ventilation system that saves energy and money. VILPE ECo Ideal Wireless is well-suited for both old and new buildings. It also offers a good solution for ventilation of warehouses and garages. If you can answer YES to any of the following questions VILPE ECo Ideal Wireless is the right choice for you: Excessive humidity or stuffy air in the bathroom or toilet? Excessive humidity in the garage, storage or warehouse? Poor ventilation during the summertime? No mechanical ventilation, i.e. no ventilation equipment? Only mechanical exhaust ventilation system with manual or timer control? Considering ventilation system options for a new warehouse, garage or outhouse? Operational principle The VILPE ECo Ideal Wireless is an automatic control system for demand-controlled ventilation. Its sensors measure the relative humidity (RH) and carbon dioxide (CO2) levels of the indoor air, and based on the information they relay the control unit adjusts the output of the ECo roof fan installed on the roof. Sufficiency of fresh supply air in the space is ensured by wall-mounted supply air valves and transfer air routes. Parts of the system Art. 73ILPE ECo Ideal Wireless ventilation control, incl. User Panel (UP), 1 pc Control Unit (CU), 1 pc Relative Humidity Sensor (RH), 1 pc Art VILPE ECo Ideal Wireless RH Sensor (relative humidity) Art. 733ILPE ECo Ideal Wireless CO2 Sensor (carbon dioxide) VILPE ECo roof fan and VILPE pass-through for your particular roofing material. Location of the system parts The VILPE ECo roof fan is to be installed on the roof with a VILPE pass-through. Pass-throughs are available for all standard roofing materials and profiles. For selecting the right pass-through, a quick selection tool is available at VILPE.COM. The User Panel (UP) of the ventilation control system is to be installed at a place with easy access, preferably near the house entrance. The Control Unit (CU, receiver) is to be installed inside the building in a place that allows easy connection with the VILPE ECo roof fan (protection: IP 21). The Relative Humidity Sensor (RH) is to be installed in spaces with potential humidity issues, such as the bathroom, toilet, kitchen or bedroom. The Carbon Dioxide Sensor (CO2) is to be installed in spaces with potential CO2 issues, such as the living-room or bedroom. Settings of the User Panel The user panel has four settings: Home, Away, High and Automatic. The Home setting is for conditions requiring constant air conditioning in order to maintain a good indoor air quality. The Away setting is used when there are no occupants present and only basic ventilation is required. The High setting is used when there is a temporary need for increased ventilation. The Automatic setting sustains the ventilation at the level of the predetermined Away level and adjusts itself according to the information from the RH and CO2 sensors. If the levels are elevated, the roof fan output is increased; if the levels are low, the roof fan output is decreased. Please refer to VILPE.COM for further information on: Quick selection tools VILPE ECo roof fans VILPE roof pass-throughs for tile, steel, bitumen and special roofing materials
7 Technical data 5 VILPE ECo roof fan + roof pass-through 6 Supply air valves 1 User Panel 2 Control Unit 3 RH Sensor 4 Sensor CO 2 7 Transfer air 1. VILPE ECo Ideal Wireless User Panel Overall dimensions (h x w x d) 84 x 84 x 15 mm 2. VILPE ECo Ideal Wireless Control Unit Overall dimensions (h x w x d) x 12 x 28 mm Weight ± 125 g Weight ± 125 g Operating Temperature Range to 4 C Shipping & Storage Temperature Range -2 to 55 C Operating Temperature Range to 4 C Shipping & Storage Temperature Range -2 to 55 C Relative Humidity - 9%, non-condensing Relative Humidity - 9%, non-condensing Ingress protection (IEC6529) IP3 Ingress protection (IEC6529) IP3 Power supply Battery Mains Power Source 23VAC ± 1%, Hz Battery type CR232 Maximum power consumption 4VA Battery lifetime 6 years Wire diameter.25 to 2.5 mm2 Communication frequency MHz Communication frequency MHz Output power at least dbm. Output power at least dbm You are not allowed to use the device outside of Europe. Multipoint communication, max 2 devices Output signal -1V 3. VILPE ECo Ideal Wireless RH Sensor Overall dimensions (h x w x d) x x 25 mm Input signals Normally Open You are not allowed to use the device outside of Europe. Weight ± 125 g Operating Temperature Range to 4 C Shipping & Storage Temperature Range -2 to 55 C Relative Humidity - 9%, non-condensing Ingress protection (IEC6529) IP3 Power supply Battery Battery type AA battery, 2x Communication frequency MHz Output power at least dbm. Measurement range: % RH Measurement accuracy 11-89%RH at -1% and 9-% 3% RH 7% RH Measurement resolution 1% RH Measurement stability 1.5% RH over 5 years You are not allowed to use the device outside of Europe. 4. VILPE ECo Ideal Wireless Sensor CO 2 Overall dimensions (h x w x d) x x 25 mm Weight ± 125 g Operating Temperature Range to 4 C Shipping & Storage Temperature Range -2 to 55 C Relative Humidity - 9%, non-condensing Ingress protection (IEC6529) IP3 Mains Power Source AC, Hz. Maximum power consumption 4VA Wire diameter.25 to 2.5 mm2 Communication frequency MHz Output power at least dbm Optimal measurement range 4 to PPM Measurement accuracy (within optimum 4 PPM + 2% of reading at 2 C range, >1min after powerup) Stabilization period after power-up 2 minutes You are not allowed to use the device outside of Europe. /ECO
8 Printed matter SK Tuote Oy Founded on 1975, SK Tuote Oy is the leading company developing and manufacturing ventilation equipment and speciality roof products in Finland, the Baltic countries, Russia and the Nordic countries. SK Tuote is a reliable, stable and a determined partner. Its products are known for the VILPE brand. Quality and the Environment SK Tuote Oy is most devoted on the quality of company products as well as its operations. The management system of SK Tuote has been granted both the ISO 91:8 quality certificate and the ISO 141:4 environmental certificate. These certifications cover the product development, manufacturing and sales of VILPE products. VILPE products improve the quality of housing and living, ensure fresh indoor air, reduce health risks and prolong the lifespan of the structure. VILPE products are innovative and high-quality as well as responsibly designed, manufactured and certified solutions. Continual improvement of our operations and products is central to SK Tuote; after all, it means safety and long-lasting comfort for end users. VILPE is a brand of safe building and living. The primary objective of the quality system of SK Tuote Oy is to provide quality fulfilling our customers needs. Environmental objectives include developing energy-efficient products and production methods, decreasing the amount of waste and increasing recyclability of plastic materials in the entire product lifespan. SK Tuote 1375/Waasa Graphics 2.217, SK Tuote Oy Kauppatie 9 FI-6561 Mustasaari FINLAND Sales and technical support Tel sales@vilpe.com
Duct Air Quality Sensors
1 962 QPM2102D QPM2160D, QPM2162D QPM2100, QPM2102 QPM2160, QPM2162 Duct Air Quality Sensors QPM21 With maintenance-free CO 2 sensing element based on optical infrared absorption measurement (NDIR 1 )
More informationDX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION
DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION 2 AERECO DX system DX SYSTEM A COMPLETELY NEW HEAT RECOVERY VENTILATION RANGE With the experience of a very innovative room-by-room demand
More informationRoom Air Quality Sensors
1 961 1961P1 1961P2 QPA2 QPA2D Room Air Quality Sensors QPA2 With maintenance-free photoacoustic CO 2 sensing element and depending on the type of sensor VOC 1) sensing element, based on a heated tin dioxide
More informationfor relative humidity and temperature
1 861 1861P01 Duct sensor for relative humidity and temperature QFM65 Operating voltage AC 24 V Signal output DC 0...10 V for relative humidity and temperature Measurement accuracy ±3 % r. h. within the
More informationFlexit air handling units UNI 2, 3 og 4
Flexit handling units UNI 2, 3 og 4 energy efficient ventilation for a healthy indoor environment FOR A HEALTHY INDOOR ENVIRONMENT Energy-efficient ventilation Flexit UNI 2, 3 and 4 The handling units
More informationCVE ECO 2 Range. System Brochure Continuous Mechanical Extract Ventilation Appendix Q Eligible
CVE ECO 2 Range System Brochure Continuous Mechanical Extract Ventilation Appendix Q Eligible CVE ECO 2 Applications The Itho extractor unit model CVE ECO 2 has been developed for use as a very quiet and
More informationRoom air quality sensors
1 961 1961P01 QPA20 QPA20 D 1961P02 Room air quality sensors QPA20 Use With maintenance-free CO 2 sensing element based on optical infrared absorption measurement (NDIR 1) ) and depending on the type of
More informationHome. evohome multi-zone, Lyric T6 programmable thermostat and Single Zone thermostat. Smart Heating Controls THE COMPLETE CONNECTED CHOICE
Home evohome multi-zone, Lyric T6 programmable thermostat and Single Zone thermostat Smart Heating Controls THE COMPLETE CONNECTED CHOICE A smart heating solution for all Honeywell offers a truly smart
More informationTechnical Instructions Document No. CE1N1961 March 17, Room CO 2 and Air Quality Sensors. Description. Features. Application
Document No. CE1N1961 QPA20 Room CO 2 and Air Quality Sensors Description The Q-Series Room Carbon Dioxide (CO 2 ) and Air Quality Sensors are especially suited for applications where precise, stable carbon
More informationGas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 4500PPM. Merlin CO2 Monitor. Rev: 11 Date:
Gas Safety Products 4500PPM Installation, operating and maintenance Read these instructions carefully before operating or servicing Rev: 11 Date: 09-07-18 1 * The unit should be installed by a competent
More informationPRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.
PRODUCT DATA COMPACT P - SERIES BY NILAN Domestic Passive heat recovery Active heat recovery Ventilation < 300 m 3 /h Comfort heating Comfort cooling Sanitary hot water production Heating THE VENTILATION
More informationFlexit air handling units C2 and UNI 2, 3,4
Flexit handling units C2 and UNI 2, 3,4 energy efficient ventilation for a healthy indoor environment A FOR A HEALTHY INDOOR ENVIRONMENT Energy-efficient ventilation Flexit C2 and UNI 2, 3, 4 The handling
More informationfor relative humidity and temperature
1 860 1860P01 Duct sensor for relative humidity and temperature QFM651 Operating voltage AC 24 V Signal output DC 010 V for relative humidity Signal output L&S Ni 1000 (passive) for temperature Measurement
More informationSmart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable
Smart Smart IR model (check applicable) is recognized as serviceable Service instruction SALES DATE MANUFACTURED ON (DATE): SOLD APPROVAL MARK SMART-EN-04 BLAUBERG Company is happy to offer your attention
More informationSINGLE-ROOM HEAT AND ENERGY RECOVERY UNITS
SINGLE-ROOM HEAT AND ENERGY RECOVERY UNITS SINGLE-ROOM HEAT RECOVERY UNITS FRESHBOX 60 Use q Heat recovery single-room air handling unit for supply and exhaust ventilation. q Efficient energy-saving single-room
More informationThe easier, smarter, heating system
The easier, smarter, heating system Wiser Multi-zone heating made easy wiser.draytoncontrols.co.uk smart meet Wiser Introducing Wiser, the beautifully simple multi-zone heating system from Drayton. Easy
More informationROLL-DOWN FIRE DOORS AND SMOKE CURTAINS
ROLL-DOWN FIRE DOORS AND SMOKE CURTAINS WHEN IN NEED, CHAMPION DOOR FIRE IS THE ANSWER Champion Door Fire is a domestic specialist solution for properties where doors must conform to fire safety standards.
More informationZehnder Comfosystems. ComfoAir 180 Datasheet
Zehnder Comfosystems Heating Cooling Fresh Air Clean Air ComfoAir 180 Datasheet Zehnder Comfosystems ComfoAir 180 Physical specifications The Zehnder ComfoAir 180 heat recovery ventilation system is an
More informationDuct Temperature Sensors
1 762 1761P03 1762P01 Mounting flange AQM630 QAM21 Symaro Duct Temperature Sensors QAM2161040 QAM2171040 Active sensors for acquiring the air temperature in air ducts AC 24 V or DC 13535 V Signal output
More informationQFM21... Duct sensors. Symaro. for relative humidity and temperature
1 864 1864P01 Symaro Duct sensors for relative humidity and temperature QFM21... Operating voltage AC 24 V / DC 13.5...35 V Signal output DC 0...10 V / 4 20 ma for relative humidity Signal output DC 0...10
More informationfor relative humidity and temperature with calibration certificates
1 859 1859P01 1859P02 QFA4160 AQF4150 Symaro Room Sensor for relative humidity and temperature with calibration certificates QFA4160 Operating voltage AC 24 V or DC 13.5...3 Signal output DC 0...10 V for
More informationWireless room thermostat with LCD
s 1 424 RDD100.1RF RCR100RF Wireless room thermostat with LCD for heating systems RDD100.1RFS Roomom temperature control Comfort, Economy and Protection mode 2-position control with On/Off control output
More informationQAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products
1 821 1821P01 Frost sensors for use on the air side Active capillary tube sensor for measuring the lowest temperature within a range of 0 15 C Operating voltage AC 24 V Signal output DC 0...10 V Use On
More informationThe easier, smarter, heating system
The easier, smarter, heating system Wiser Multi-zone heating made easy wiser.draytoncontrols.co.uk smart meet Wiser Introducing Wiser, the beautifully simple multi-zone heating system from Drayton. Easy
More informationLTR-3-EC LTR-3-ECE PLANNING, INSTALLATION AND OPERATION INSTRUCTIONS
LTR-3-EC LTR-3-ECE PLANNING, INSTALLATION AND OPERATION INSTRUCTIONS Unit F3, Maynooth Business Campus, Maynooth, County Kildare Phone 01-6290621, fax 01-6290623 www.enervent.ie Enervent OY; rev. 2006-3
More informationQAF63.2-J QAF63.6-J. Frost detectors. for use on the air side
s Frost detectors for use on the air side QAF63.2-J QAF63.6-J Active capillary tube sensor for acquiring the lowest temperature within a range of 0 15 C Operating voltage AC 24 V Signal output DC 0...10
More informationTHERMASREG TR 040 THERMASREG TR 060
THERMASREG TR 040 THERMASREG Temperature controllers, one-step, Mechanical temperature controllers wet room temperature controllers THERMASREG TR 040 with switching output and stainless steel capillary
More informationQPM21 Series Duct CO 2 and Air Quality Sensors
Document No. CE1N1962 QPM21 Series Duct CO 2 and Air Quality Sensors Description Features Application The Carbon Dioxide (CO 2 ) Duct Sensors are directly wired to the controller via twisted pair and/or
More informationQFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates
1 883 1883P01 1883P02 1859P04 QFM41.. AQF4150 AQF3153 Symaro Duct sensors for relative humidity and temperature with calibration certificates QFM41.. Operating voltage AC 24 V / DC 13.5...35 V Signal output
More informationEndura Delta. Demand- and app-controlled ventilation system with heat recovery
Endura Delta Demand- and app-controlled ventilation system with heat recovery Introduction < Endura Delta As an occupant we are increasingly aware of the fact that energy-efficient construction should
More informationBreathe Fresh Air at Home
Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans Breathe Fresh Air at Home Residential Ventilation 2 Category name / Registername
More informationRoom Temperature Sensors
1 749 1749P01 QAA201 Symaro Room Temperature Sensors QAA201 Active sensors for acquiring the room temperature Operating voltage AC 24 V or DC 135 35 V Signal output DC 010 V or 420 ma Use In heating, ventilation
More informationSmoke extract fan SMHA HATCH
12.11.2012 Contents Product overview... 3 Construction... 4 Specification... 5 Selection... 6 Installation... 7 Electrical connections... 8 Dimensions and weights... 9 Product code and accessories... 10
More informationQFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature
1 864 1864P01 Symaro Duct Sensors for relative humidity and temperature QFM21... Use Type summary Operating voltage AC 24 V or DC 13.5...3 Signal output DC 0...10 V for relative humidity Signal output
More informationROOFTM. roof products. Roof products for a complete ventilation system HOME VENTILATION
TM roof products Roof products for a complete ventilation system Power roof ventilator, radon fan, exhaust air hood, venting hood. With roof ducts for various roof coverings. Smart solution for all roof
More informationSolar Powered Roof Ventilation Fan
Solar Powered Roof Ventilation Fan Overview High Efficient Excellent Ventilation Free Solar Panel Power BLDC Motor Quiet Running Strong Fan Case Durable In Use Energy Saving Ecofriendly Easy Installation
More informationDuct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature
1 882 1882P01 Symaro Duct Sensors for relative humitidy (high accuracy) and temperature QFM31 Use Examples Operating voltage AC 24 V / DC 1353 Signal output DC 010 V / 4 20 ma for relative humidity and
More informationCONTROL YOUR HOME FROM EVERYWHERE
CONTROL YOUR HOME FROM EVERYWHERE WITH YOUR SMART PHONE OR TABLET Control and monitor your home automation system anywhere! The future is the remote controlled home and we do this with affordable innovative
More informationApplications: 27. NETIChome mobile ios 28. NETIChome mobile Android. NETIChome basic elements
INDEX 1 NETIC... 2 2 Door/Window detector MINI... 2 3 FOUR sensor... 3 4 Smoke detector... 3 5 Flood detector... 4 6 ILLumination sensor... 4 7 Lamp holder... 5 8 Siren... 5 9 Power meter & switch... 6
More informationAIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!
AIR HANDLING UNITS RIS P EKO 3.0 1 2 3 4 fans! Efficient EC E f f i c i e n c y up to 94%! E x t r e m e l y low height! New range - 5 sizes, 20 models! Contents Basic features 4 RIS P EKO 3.0 full range
More informationG Installation manual Solitude - dmev unit
G G Installation manual Solitude - dmev unit Read this manual carefully before using the product and keep it in a safe place for reference. This product was constructed up to standard and in compliance
More informationAir handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses
REC Temovex 4S-EC-RS Experts on indoor climate in low-energy houses RT 4S-EC-RS REC Temovex 4S-EC-RS ECO2 control system for low-energy and passive houses Comprises: - Air flow boost for warm and cold
More informationControlled mechanical ventilation GB 03
RECUPER SLIM 2018 Controlled mechanical ventilation GB 03 ir conditioning Systems to install Recover... your wellbeing The home is a precious asset where we all spend a major time of your life. So it s
More informationMicrobiological. Smart Safety Cabinet
WORLDS MOST SILENT EN 12469 / ISO 3744 Microbiological Smart Safety Cabinet Sustainable safety Think smart It is not only the technical specifications that prove Biowizard Platinum SMART reputation for
More informationSmart Thermostat RDS110
Smart Thermostat RDS110 To control heating applications in apartments, single family homes, dormitories, and other residential as well as commercial spaces. Backlit, auto-dimming 90 mm color LCD touch
More information2013 innovation. Room-by-room demand controlled heat recovery ventilation
2013 innovation Room-by-room demand controlled heat recovery ventilation 2 Revolution in the world of heat recovery ventilation Through its new ventilation system, which combines heat recovery and room-by-room
More informationPRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h
PRODUCT DATA COMFORT 300 TOP BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 325 m 3 /h COMFORT 300 TOP Product description The Comfort 300 Top is an energy-efficient
More informationAdsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system
Comfort air conditioning 56/58 Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system 58 3 0 - simplified illustration Automatically selects the most economical
More informationROOM-BY-ROOM DEMAND CONTROLLED HEAT RECOVERY VENTILATION
ROOM-BY-ROOM DEMAND CONTROLLED HEAT RECOVERY VENTILATION 2 AERECO Room-by-room demand controlled heat recovery ventilation REVOLUTION IN THE WORLD OF HEAT RECOVERY VENTILATION Through its new ventilation
More informationRoom Temperature Sensor
2 701 Synco 900 Room Temperature Sensor QAA910 Wireless room temperature sensor for acquiring the room temperature RF communication based on KNX standard (868 MHz, unidirectional) Battery-powered by commercially
More informationRoom Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature
1 858 1858P01 1858P02 1859P02 Symaro Room Sensors for relative humidity (high accuracy) and temperature AQF3150 QFA31 Use Operating voltage AC 24 V / DC 1353 Signal output DC 010 V / 4 20 ma for r h and
More informationAXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL
TUBO-M/MZ AXIS-QA AXIS-Q TUBO-F AXIS-QR AXIS-F AXIS-QRA AXIS-QA G AXIAL FANS EN OPERATION MANUAL www.blaubergventilatoren.de CONTENT 3 Introduction 3 General 3 Safety rules 3 Transport and storage requirements
More informationRoom Temperature Controller
3 331 Synco 100 Room Temperature Controller with 2 outputs DC 0 RLA162 Room temperature controller for basic ventilation, air conditioning and heating plants Compact design with 2 analog control outputs
More informationQFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature
1 864 1864P01 Symaro Duct Sensors for relative humidity and temperature QFM21 Operating voltage AC 24 V / DC 13535 V Signal output DC 010 V / 420 ma for relative humidity Signal output DC 010 V / 420 ma
More informationPRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h
PRODUCT DATA COMFORT 00 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 800 m /h COMFORT 00 Product description The Comfort 00 is an energy-efficient ventilation
More informationPRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.
PRODUCT DATA COMBI 300 POLAR BY NILAN Ventilation with passive & active heat recovery Domestic Passive heat recovery Active heat recovery Ventilation < 350 m 3 /h Comfort heating Comfort cooling COMBI
More informationPRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h
PRODUCT DATA COMFORT 5000 BY NILAN Ventilation & passive heat recovery Commercial Passive heat recovery Ventilation < 5300 m 3 /h COMFORT 5000 The Comfort 5000 is a ventilation unit suitable for central
More informationIntelligent Infrared Carbon Dioxide Module (Model: MH-Z14A)
Intelligent Infrared Carbon Dioxide Module (Model: MH-Z14A) User s Manual V1.01 Valid from Sep 24 th, 2015 Zhengzhou Winsen Electronics Technology CO., LTD. Statement The copyright of this manual belongs
More informationTechnical Information HXV - HRV Ventilation
Technical Information HXV - HRV Ventilation General description Technical data Accessories VENTILATION HXV 5 1 General description 1.01-1.02 2 Technical data 2.01-2.02 3 Accessories 3.01-3.03 HRV 5 4 General
More informationPRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h
PRODUCT DATA COMFORT 40 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 40 m /h COMFORT 40 Product description The Comfort 40 is an energy-efficient ventilation
More informationThe easier, smarter, heating system
The easier, smarter, heating system Wiser Multi-zone heating made easy wiser.draytoncontrols.co.uk smart meet Wiser Introducing Wiser, the beautifully simple multi-zone heating system from Drayton. Easy
More informationGas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2
Features Integrated (built-in NO2 sensor / detector (Electro chemical sensor type Measuring ranges 0-10 ppm, 0-20 ppm or 0-30 ppm LCD display to show actual in ppm Status LED indication Normal operation
More informationINTELLIGENT AXIAL FAN user's manual
ACCEPTANCE CERTIFICATE The fan is duly recognized as serviceable. ifan Approval mark Manufactured on (date) Sold (name and stamp of the trade company) INTELLIGENT AXIAL FAN user's manual model VENTS ifan
More informationSmoke Master SMPA Compact pressurisation system
Smoke Master SMPA Compact pressurisation system Fläkt Woods FILO E 2009.07 2 All rights reserved. Contents System overview...4 Design and operation...5 Technical specification...6 Electric and control
More informationZ-DENS Z-FLEX. Polypropylene Vent Systems for High Efficiency Condensing Appliances. Single Wall Rigid Flexible Liner Concentric
Z-FLEX Advanced Venting Solutions Z-DENS Polypropylene Vent Systems for High Efficiency Condensing Appliances Single Wall Rigid Flexible Liner Concentric Z-Flex Joins Forces with Cox Geelen Z-Flex North
More informationGüntner Info GVX. with microox technology kw. Always a step ahead: microox condenser system with maximum installation flexibility
Güntner Info GVX with microox technology 6 525 kw Always a step ahead: microox condenser system with maximum installation flexibility The new standard for flexibility, technology Energy-saving operation
More informationSmoke Master SMIA Compact pressurisation and smoke exhaust system
Smoke Master SMIA Compact pressurisation and smoke exhaust system Fläkt Woods FIFLO EN 2009.09 2 All rights reserved. Contents System overview... 4 Design and operation... 5 Technical specification...
More informationHome. evohome WiFi MULTI-ZONE SYSTEM
Home evohome WiFi MULTI-ZONE SYSTEM evohome is a sophisticated heating system that ensures you can create and individually control up to 12 heating zones in domestic properties. evohome will also control
More informationevohome controls evohome consists of a number of quality components manufactured by the UK s leading manufacturer of home heating controls.
evohome controls evohome consists of a number of quality components manufactured by the UK s leading manufacturer of home heating controls. Radiator controllers The radiator controllers use two-way communication
More information66 on. Central ventilation system ZLS-DV EC according to DIN Central ventilation system ZLS EXTRACT AIR FIRE PROTECTION OUTSIDE AIR
Central ventilation system ZLS Central ventilation system ZLS-DV EC according. ZLS-DV EC is the ideal central ventilation system in multi-storey construction according. EXTRACT AIR OUTSIDE AIR FIRE PROTECTION
More informationSiMAP heating control. SiMAP controls - you make the savings
SiMAP heating control SiMAP controls - you make the savings A router is installed in the stairway to route the sensor signal to the controller. What is SiMAP Control? SiMAP Control is a completely new
More informationOslo Range Fast, Efficient, Scandinavian Heating
Oslo Range Fast, Efficient, Scandinavian Heating LIFETIME WARRANTY www.nobo.co.nz GLEN DIMPLEX THE WORLD LEADERS IN ELECTRIC HEATING NOBO are part of the Glen Dimplex Group, the world s largest electric
More informationEnergy efficient lighting control
Energy efficient lighting control 2015/2016 Brighter Lighting With intelligent sensors, Aura Light takes lighting control to the next level. The smart components and systems enable us to simplify the installation
More informationVallox INSTRUCTIONS FOR USE AND MAINTENANCE. Compact. Supply and extract air ventilation with heat recovery
Vallox 1.09.349E 19.5.2009 VALLOX INSTRUCTIONS FOR USE AND MAINTENANCE 70 Compact CODE 3475 Supply and extract air ventilation with heat recovery For blocks of flats, terraced houses and detached houses.
More informationRoom thermostat with Auto Timer, Option External Input
s 1 422 Room thermostat with Auto imer, Option External Input for heating systems RDE100.. Room temperature control 2-position control with On/Off output for heating Comfort, Economy, Auto timer and Protection
More informationInstallation manual Mori HR
G G Installation manual Mori HR Read this manual carefully before using the product and keep it in a safe place for reference. This product was constructed up to standard and in compliance with regulations
More informationSemi flush-mount room thermostats
s 1 440 RDD310/EH RDE410/EH Semi flush-mount room thermostats for control of electric floor heating systems and for hydronic zone control systems RDD310/EH RDE410/EH Key features of both types of thermostats:
More informationSilencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter
VALLOX Product Code: 3158400 L 3158410 R SILENCER (OPTIONAL) INSTRUCTIONS FOR USE AND MAINTENANCE WATER CIRCULATED POST-HEATING UNIT (OPTIONAL) ELECTRIC POST-HEATING UNIT (OPTIONAL)) PREHEATER (OPTIONAL)
More informationwith minimal heat loss for a pleasant and healthy living environment
VENTILATION SYSTEM Up to 87% of heat recovery at 100% air exchange Controlled and high quality room ventilation with minimal heat loss for a pleasant and healthy living environment Save up to 21.604 in
More informationDEHUMIDIFIERS & VENTILATORS
2015/2016 DEHUMIDIFIERS & VENTILATORS MCS GROUP www.mcsworld.com I CHOOSE MASTER DEHUMIDIFIERS. WHY? SAVE TIME dehumidifiers speed up many renovation and construction works REDUCE THE INVESTMENT COSTS
More informationHigh bay LED lighting fixture
Supporting bracket EWL - Zone 1, 2, 21, 22 - Replacing traditional discharge lamps of up to 750W - Savings in energy, maintenance and installation costs - Instant, brilliant illumination - Suitable for
More informationRoom thermostat with Auto Timer, Option External Input
s 1 422 Room thermostat with Auto imer, Option External Input for heating systems RDE100.. Room temperature control 2-position control with On/Off output for heating Comfort, Economy, Auto timer and Protection
More informationQFM21... Duct Sensors. Siemens Building Technologies HVAC Products
For latest prices and delivery to your door visit MyTub Ltd - 0845 303 8383 - wwwmytubcouk - info@mytubcouk 1 864 1864P01 Symaro Duct Sensors for relative humidity and temperature QFM21 Use Operating voltage
More informationResidential Carbon Friendly Ventilation SAP Q Eligible. ventilation
Residential Carbon Friendly Ventilation SAP Q Eligible ventilation Whole House Mechanical Ventilation - MVHR, MEV, dmev SAP Q ELIGIBLE PRODUCTS Energy Efficient Ventilation About Appendix Q SAP is the
More informationEnergy consumption in properties
Energy consumption in properties Glenn Malmberg, Availability of energy Energy and the environment are areas that are in focus both globally and nationally, not least since Al Gore travelled around the
More informationTurbo. Service Instructions
Turbo Service Instructions E BAUBERG Company is happy to offer your attention a new highquality inline mixed-flow Blauberg Turbo fan. The solid team of highqualified professionals with many years of working
More information- Schedule with up to 3 ON periods per day to suit the comfort needs. - Hot water Boost function for temporary override
LYRIC T6R-HW SMART THERMOSTAT PRODUCT SPECIFICATION SHEET The Lyric T6R-HW smart thermostat is designed to provide automatic time and temperature control of heating and stored Hot water systems in homes
More informationAir Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses
NEW! REC Temovex Blue 4 Experts on indoor climate in low-energy houses REC Temovex Blue 4 Third generation of our Temovex units! - Dual counterflow heat exchangers with over 9% efficiency * - SFP < 1,
More informationHealthy, comfortable and energy-efficient ventilation
Healthy, comfortable and energy-efficient ventilation partner Renovent Excellent 180, 300 and 400 Silent and energy-efficient ventilation 300/400 180 Central ventilation The Renovent Excellent is a mechanical
More informationSmartVent. NZ's home ventilation specialists. Become the climate expert in your home. SMARTVENT HOME VENTILATION SYSTEMS
NZ's home ventilation specialists SMARTVENT HOME VENTILATION SYSTEMS www.smartvent.co.nz Become the climate expert in your home Introduction to Ventilation Why ventilate? Adequate ventilation of your home
More informationWORLD VENTILATION LEADER SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS
WORLD VENTILATION LEADER IO EM.COM SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS VENTS reserves the rights to modify any of its products featuers, designs, components and specifications
More informationOXeN. Ductless ventilation with heat recovery.
OXeN Ductless ventilation with heat recovery www.flowair.com We are an expert in providing complete heating and ventilation solutions for medium and big cubature buildings. Our offer consists of three
More informationColt CoolStream Adiabatic Cooling & Ventilation System
Colt CoolStream Adiabatic Cooling & Ventilation System Colt CoolStream Adiabatic Cooling & Ventilation System Colt coolstream Adiabatic cooling & ventilation system DESCRIPTION Colt CoolStream is a natural
More informationRoom thermostat with Auto Timer, Option External Input
s 1 422 Room thermostat with Auto imer, Option External Input for heating systems RDE100.. Room temperature control 2-position control with On/Off output for heating Comfort, Economy, Auto timer and Protection
More informationSmoke Control Ducts and Dampers For Single Compartment Applications. Fulfilling new requirements for EN product standards for CE Marking
Smoke Control Ducts and Dampers For Single Compartment Applications Fulfilling new requirements for EN product standards for CE Marking New Smoke Control Product Range Fläkt Woods Smoke Control Ducts and
More informationMovement-based energy control
04 Movement-based energy control 94 International catalogue 2015 4.1 Microwave-based movement sensors 4.2 PIR-based movement sensors 4.2.1 Ceiling-mount 4.2.2 Wall-mount 4.3 Twilight switches 4.4 LED lights
More informationP R O D U C T D ATA S H E E T
PGF- Effective Gas Safety Proving and Gas Detection Controller Gas Pressure Proving For use with Natural Gas LPG - or Laboratory gas supplies, both high and low pressure ensuring system integrity prior
More informationSensepoint XCL. Gas Detection. Fixed Gas Detector FEATURES & BENEFITS. Flexible Output Options. Visual Integration. Faster Installation
Sensepoint XCL Fixed Gas Detector Gas Detection Sensepoint XCL is a fixed point gas leak detector that is designed to meet the needs of commercial and light industrial applications. With over 50 years
More informationCode of Practice - Ventilation- Mechanical Extract Ventilation (MEV) + Mechanical Ventilation with Heat Recovery (MHVR)
Code of Practice - Ventilation- Mechanical Extract Ventilation (MEV) + Mechanical Ventilation with Heat Recovery (MHVR) Contractors Requirements & Competency This section outlines the general Standards
More informationPRODUCT DATA COMPACT S BY NILAN. Sanitary hot water production. Passive heat recovery. Comfort heating. Ventilation < 375 m 3 /h. Active heat recovery
PRODUCT DATA COMPACT S BY NILAN Domestic Passive heat recovery Active heat recovery Ventilation < 375 m 3 /h Comfort heating Comfort cooling Sanitary hot water production COMPACT S Product description
More information