Installation and Technical Manual

Size: px
Start display at page:

Download "Installation and Technical Manual"

Transcription

1 140 S S Installation and Technical Manual Stand Okt. 2009

2 Contents Page Designated use 3 Security instructions 4 Description 5 Installation notices /Suction of combustion air 6 Assembly indications / Starting up 8 Setting into operation 9 Servicing 11 Mounting 12 Exhaust fumes 13 Over view / Quick selection 14 Technical data S 15 Technical data S 16 Table of measure S 17 Techical data K-Type 18 Attachments 19 Warm air heater atachments 20 Warm air heater electric accessories 24 Room thermostat 26 Burner assembly 27 Setting into operation fan motor 29 Cone belt exchange 31 Tension V-belts 32 Assembly of suck and pressure side accessories 33 Accessories 34 Switch box 35 Circuit diagram 140 S 260 S 36 Circuit diagram 290 S 430 S 37 Circuit diagram 490 S 730 S 38 Circuit diagram burner level 2 40 Garantierequest 42 Basic instructions Kroll space heaters 140S bis 730S are the result of thenth of years of experience and intensif developement work. We are convinced of handing you over a high-quality product. Never the less, the heater must be installed set into operation and tested by measurings correspondending to respective circustances by a specialist. Read the operation instructions carefully, prior to installing and comissioning the heater All details stated, refering tue installation and setting into operation must be effected and observed carafully in order to grant an economic operation free of malfuctions. The space heaters are proved in accordance to DINEN and must be equipped with an automatic control box, which is permitted for the space heater Edition: Drawing number: Technical changes in the sense of product improvement reserved Privileg of the producer: Firma Kroll GmbH 2 conformément aux circonsstance

3 Designated use Destignated use: Everywhere, where heat is needed or to keep free of icing or for an agreable climate Kroll mobil space heaters are the ideal partners - heating warehouses and store roomes - heating of places of work in big shop floors and workshops - heating greenhouses - for assembling and repairing Inappropriate use These space heaters are not suitable for household use must be used only by persons who have been instructed about their operation Responsibility In order to qualify for guarantee, the device must be installed and commissioned by a specialist. the settings are to be recorded in a measurement certificate. Please fill out all the points of guarantee form correctly, sign and send it to Kroll. Please note that in case of missing mea-suring vales no guarantee certificate will be issued. The guarantee will only be granted if a regular servicing is carried out at least once a year and in accordance with the Kroll operating instructions. The results must be recorded in the applicable measurement certificates. The usual guarantee period granted on our device covers 24 months after the delivery - the date of the invoice being decisive. Damage during transport Transport damages must be noted on the forwarders receipt and signed by the driver. Your dealer must be notified of any technical damage before the appleance is assembled and set into operation. The heater is only be started up after competent repair. Any cases of consequential damage due to the failure of the space heaters during operation will be excluded. 3

4 Security instructions Installation regulation A B C D E F The exhaust fumes must be conducted into the open through a chimney or flue approved for oil or gas heating appliances and in acoordance with all applicable standards. The chimney can be in masonry or metal The opening of the chimney must clear the roof by at least 1 m, and the roof ridge by at least 0,5 m. It must be expo-sed to the free wind conditions. The opening of the chimney must not be in the vicinity of a window or a balcony. Temperature of exhaust fumes When setting into operation and adjusting, set temperature of exhaust fumes for at least 160 C. Installation of flue pipes A catch elbow must be connected to the flue connector for rain-water condesation Horizontally installed flue pipes (max.1/3 of total flue pipe length) must have a continuous gradient of 2cm per metre. Flue pipes must be interconnected in the direction of the draft. Installation or the pipe system Pay attention to the maximum pressure. If this exceeded, the air volume of the fan will fall and both the flue gas and warm air temperature will rise. Ventilation Sufficient air for combustion must be available (avoid low pressure in the installation room). This is assured when: e.g. the volume of the room in m³ is a minimum of 10 times the rated heat load in kw of all the heating appliances in the room. Normal circulation is to be guaranteed via windows and doors. If low pressure or dust in the room air are not avoidable, the burner must be encased and the air supply taken from outside the room. Warning The space heater is only to be installed on combustible floor. An area of 1 m around the heater is to be kept clear to ensure an unobstructed flow of air to and from the heater. Do not switch off electrical supply and main switch until the space heater has cooled down. Non-compliance invalidates the factory guarantee. 4

5 Whe run with gas, the flue pipe must be put into the flue outlet by means of an adapter pipe. 5

6 Description Warm air heaters, type S, are direct-fired and highly variable units. In contrary to other heating systems they can be installed inside the room. The devices are made exclusively for industrial use in halls and large capacities of each kind, especially in locations where heat is immediately needed. The warm air heaters (S) are made of high-quality material and are manufactured clean cut. Thus they guarantee trouble-free operation and durability. Special attention is given to a simple and quick installation and ease of servicing. The case is constructed as solid galvanized framework. The double-shelly screwed panel consists of 1 mm galvanized steel sheet - inside and outside. Due to the framework construction and the removable panels, the warm air heaters can be dismounted. Radiator: The combustion chamber is made of chrome-alloyed, high-heat resistance stainless steel. The tubular heat exchanger is made of standard steel with baffle. Combustion chamber and heat exchanger a re screwed via a flanged joint. Thus the whole unit can easily be decomposed in two pieces. Therefore it can be set up quickly in small rooms, replaced or partly-renewed without any problems. Upon request the heat exchanger can be delivered in stainless steel with condensate nozzle (extra price). Fan : In the bottom part, silent tangential fans and maintenance-free ball bearing are mounted. Driving is made via a three-phase standard motor with V-belt-drive. All units are standard equipped with a switch box and a fan-burner and a safety thermostat. The plenums are open to three sides with horizontal air conduction lamellas. Upon request and extra price, further plenum solutions or a ductwork can be delivered. General information: As to the installation of the units, the respective security specifications and directives of each country have to be respected. The decrees for carrying out the Immissions Security Regulation and according to this the enacted legal decrees have to be observed as described in your country. Only tested oil burners in warm air heater-type or gas burners may be used. In case of ex factory delivered units incl. oil- or gas burner the separately additional working instructions have to be observed. Pay special attention: - To the list guidelines of warm air heaters - To the general safety-relevant requirements - To set up and operate according to your countries regulations - Fuel supply according to your countries regulations - Technical rules for gas installation according to your countries regulations - the VDE - regulations - Warm air heaters are as fire places in principle permission and indicate requiring. - consider the rules for the prevention of accidents and other safety-relevant regulations and guidelines 6

7 Installation notices Suction of combustion air As to the installation of the units, the respective security specifications and directives of each country have to be respected. Place of installation Before installation the following requirements have to be proved: a) fire protection b) function (e.g. room heating, with plenum or duct system, negative or overpressure...) c) specific requirements as heat demand, air delivery, ambient or outer air demand, room temperature, air diffusion, space capacities) d) connection to the chimney e) installation, repair and maintenance possibilities f) relation room volume - rated heating power, especially in naturally ventilated rooms. A sufficient natural air delivery, necessary for the combustion, means e.g. that the room volume in m ³ is equivalent to the tenfold rated heat load in kw of all heating units in the room and that windows and doors assure a natural ventilation. Good and natural ventilation means e.g. 1. the room volume in m ³ is equivalent to the 30fold rated heat load of all heating units in the room and windows and doors assure natural ventilation 2. the room offers openings near floor and ceilings which cannot be locked-up, corresponding to 0,003 fold rated heat load in kw of all units in the room. Suction of combustion air The combustion air should be free of each kind of pollutants. - If - due to production conditions - pollutants (e.g. chloride, CKW, FKCW etc.) comes to the warm air heater, the combustion air for the burner should be taken from outside and a burner casing (see accessories) has to be used. The influx of enough combustion air is guaranteed when suction from: - installation room, if this meets the requirements to the volume-rated heating efficiency ratio of the construction supervision ( 4 m 3 / kw ); installation room, if this is heated by the warm air heater outside air- or secondary air-driven with guaranteed outside air rate; a fixed room power ratio is not necessary; - installation room, with not lock up openings outwards, according to the requirements of the construction supervision; - outwards, through a pipe connected with the burner/heater or its housing whose profile is big enough it must be adapted to the available free air capacity of the burner/heater and the line resistance (including the suction protective grating), that an efficient combustion is guaranteed. 7

8 Assembly indications / Starting up For installation of the apparatus you have to follow the regulations and decrees of each country. The apparatus are suitable for the use of suck in- and blow out-attachments. It has to be guaranteed, that the fan power (nominal pressure) is adapted according to each air-side resistance (test rated current) The apparatus are not suitable fort he excluding use as induction system. - The apparatus have to be installed steadfast. - Pallet or wooden frame have to be removed before installation. - In case of installation on the ground the apparatus should better be installed on a separate foundation free of tension and secure. - The suction of air may only occur according to the suction port. When the bottom of the apparatus is not designed as suction variant it has to be closed to avoid infiltrated air suction. - If heavily pollution of the air in the installation room is eventually expected you have to conduct the return air suction through appropriate filter (apparatus accessories). In this connection you have to observe the suck-side resistance and according to this you have to suit the fan power. - You have to guarantee the admission of combustion air. In case of eventually super pressure or low pressure or heavily pollution in the installation room you have to install a burner-fresh-air-suction. Pay attention to a free air suction- and air blow-out possibility. Exhaust connection An exhaust system has to be guaranteed according to the rules. The construction must be according to DIN part 1(construction and mounting of chimneys), the measuring according to DIN 4705 part 1 or part 2 (firing technological calculation of chimney dimension) The exhaust connection must be carried out workmanlike/professional after the valid regulations. Caution: The exhaust connection may only occur on chimneys which are approved before. The chimney draft may maximum amount 0,2 mbar (appropriate:. 20 Pa, 0,2 h Pa), otherwise damages of the radiator will be possible. Pay attention to extreme weather conditions, roof shapes, settings, etc. In doubtful case you have to use a draft regulator. Electric installation The electric instrument connection has to be done by authorised experts after DIN EN and VDE On apparatus with nominal heating efficiency over 50 kw you have to apply an emergency switch on good accessible place outside the installation room. It must be save towards unauthorised operation. The room thermostat (accessories) has to be attached at advantageous place for temperature regulation. The thermostat sensor may not directly be exposed to extremely cold or hot air stream. To install an automatic day/ night temperature regulation you have to operate as described before. The connection of a day/ night temperature regulation or of a room thermostat takes place at the connecting strip inside the control box (watch the circuit diagram inside the control box). Connection of fan motor The apparatus are wired completely in the factory. In case of changes or exchange of motors you have to care about the right motor connection. Doing this you always have to follow the separate attached valid circuit diagram, lying in the switch box. The start of the motors is factory adjusted till 3,0 kw directly in the Y, above 3,0 kw by a Y/ circuit. 8

9 Setting into operation The space heater and burner are controlled by the selector switch and by means of a room thermostat or via control for week program Power connection The electric connection of the machine must be done by authorized personnel according to DINEN (VDE0116-1:2005-3) and DINEN (VDE0700-1). Heating with room thermostat 1 Set selector switch to Heating 2 Set the desired room temperature The space heater heats up. When internal temperature of the appliance reaches +40 C (factory setting), the fan is set into operation.the burner switches off when the set room temperature is reached. The burner is automatically switched on again when the room temperature falls below this value. Heating with day/night mechanism 3 4 Instal control for week program according technical manual when follow as if heating with room thermostat Heating without room thermostat 5 Set selector switch to Heating The space heater heats up. When internal temperature of the appliance reaches +40 C (factory setting), the fan is set into operation. If the set temperature (factory setting +80 C) is exceeded, or if the temperature falls below this level, the temperature controller switches the burner off, or on again, as the case may be. Turning off with/without room thermostat 6 Set selector switch to 0 The fan will repeatedly start up in order to remove residual heat from the space heater. The fan must cool the combustion chamber and heat exchanger - danger of over-heating! Do not switch off electrical supply and master switch until the space heater has cooled down. Non-compliance invalidates the factory guarantee. Ventilation 7 Set selector switch to Ventilation The fan runs continuously with the burner for the room ventilation (In cas of a room thermostat set to 0 C) 9

10 Heating with room thermostat Heating with day/night mechanism Heating without room thermostat Switching off Ventilation 10

11 Servicing Servicing The heat exchanger and the combustion chamber should be thoroughly cleaned and checked by a specialist at least once a year. Kroll recommends taking out a service contract. Set selector switch to 0 before starting maintenance work on the space heater. After the heater has cooled down, the main power switch must be turned off. 1 Cleaning of combustion chamber Turn off electrical supply (see above) Loosen 4 clamping bolts on burner bracket. Remove burner. Clean combustion dchamber with brush and vacuum cleaner through the opening Fixing the burner with 4 clamping screws on the burner bracket. 2 Cleaning of heat exchanger - suction side Turn off electrical supply (see above) After have removing the corresponding front panel, loosen the cleaning cover, remove the seal and clean by means of brush and aspirator. Put on new seals and mount in reversed order. 3 Cleaning of heat exchanger - air outlet side Turn off electrical supply (see above) After having removed the corresponding side panesl, loosen the cleaning cover, remove the seal and clean by means of brush and aspirator. Then put on new seals and mount in reversed order 11

12 Mounting Mount the space heaters a) only on fire proof walls and according to the relevant standards (equivalent to DIN 4794 part 5) b) Mount levelly c) The installation of the space heater must comply with the building regulations and all other applicable standards an legislation and standards: DVGW-TRGI 1986 DIN 4756 und TRF 1988 DVGW Standard G 600 Additional technical regulations TRF 1988 are to be observed when installing space heaters in room ground level. Power connection The electric connection of the machine must be done by authorized personnel according to DINEN (VDE0116-1:2005-3) and DINEN (VDE0700-1). Pay attention to correct running direction with the three-phase A.Cmotors. Set motor protector to correct value. Roomthermostat Do not mount in cold or warm air stream. Gas connection The connection must be carried out in accordance with the applicable technical regulations. Connection and setting into operation must be carried out by a qualified gas-fitter. Check gas supply and connection for leaks. Adjust burner to local conditions. Check electrical connection before setting into use. Oil connection The connection will made by the burner service. Oil- or gas burner The adjustment and setting into operation may only be carried out by the after-sales service of the respective burner manufacturer or an authorized specialist firm. The values given by the burner manufacturer must be complied with. Burner service Kroll recommends taking out a service contract. 12

13 Exhaust fumes Whe run with gas, the flue pipe must be put into the flue outlet by means of an adapter pipe. The opening of the flue pipe must clear the roof at least 1 m and theroof ridge by at least 0,5 m. It must also be exposed to the free wind conditions. The opening of the flue pipe must not be in the vincinity of a window or a balcony. Installation A catch elbow must be connected to the flue connector for rain-water and condensation. Horizontally installed flue pipes (maximum only on third of the total flue pipe length) must have a continuos gradient of 20 mm per meter. Flue pipes must be interconnected in the direction of the draft. For a safe operation of the apparats it is absolutely necessary to use the Kroll flue gas accessories. Setting into operation for test run Set selector switch to - Heating without room thermostat Turning off Set selctor switch to 0 Examining of the measuring values according to technical data and registering in the demand for garanty 13

14 Over view / Quick selection Completely with suction components and plenum open to three sides; with drive, switch box, thermostat, totally wired Without suction and blow components for higher pressure with drive, switch box, thermostat, completely wired, lying or standing types Quick selection Volume Type Rated heating power Air delivery Efficiency motor m ³ kw m ³ /h kw S , S , S , S , S , S , S , S , S , S , S ,00 14

15 Technical data 140S S Warm air heater for oil- or gas firing, with plenum. Completely with suction components and plenum 210, open to three sides, with drive, integrated switch box, exhaust socket to the back, completely wired with drilled burner plate (inside the burner: extra price). 140S 170S 195S 260S 290S Rated heating power QN [kw] Rated heat load QB [kw] Rated air rate 20 C VN [m ³ /h] Hot air rate V [m ³ /h] Temperature rise t [K] Exhaust temperature difference t [K] Efficiency of firing [%] 92,7 92,0 92,6 92,1 92,7 Chimney draught demand [Pa] On-resistance (combustion chamber) [Pa] Max. oil flow [kg/h] 10,8 13,7 16, ,5 Max. gas flow [m ³ /h] 12,4 15,7 18, ,9 Blower motor performance [kw] 1,1 2,2 1,5 3,0 3,0 Outlet pressure [Pa] Noise level (without burner) standard type [db(a)] Noise level oil burner [db(a)] Noise level gas burner [db(a)] Range of throw [m] Weight (without burner) [kg] Current type and voltage CE - Ident-no. according to EU-gas units regulation CE 0085 BM 0299 (gemäß Gas-Geräte-Richtlinie 90/396/EWG) CE-0085-BM

16 Technical data 360S - 730S Technical data 360 S 730 Warm air heater for oil- or gas firing, with plenum. Completely with suction components and plenum 210, open to three sides, with drive, integrated switch box, exhaust socket to the back, completely wired with drilled burner plate (inside the burner: extra price) 360S 430S 490S 580S 650S 730S Rated heating efficiency QN kw Rated heat load QB kw Rated air rate 20 C m ³ /h Hot air rate V m ³ /h Temperature rise AtL K Exhaust temperature difference AtA K Efficiency of firing n % 91,8 92,5 92,7 92,8 92,6 92,1 Chimney draught demand Pa On-resistance (combustion chamber) Pa Max. oil flow kg/h 27,3 35,5 41,1 50,3 54,8 60,2 Max. gas flow m ³ /h 31,3 40, ,5 62,7 68,9 Blower motor performance kw 5,5 5,5 7,5 5,57, 11 Outlet pressure Pa Noise level (without burner) standard type db(a) Noise level oil burner db(a) Noise level gas burner db(a) Range of throw m Weight (without burner) kg Current type and voltage V / Hz 3 Ph x 400 V x 50 Hz CE - Ident-no. according to EUgas units regulation CE-0085-BM0299 DVGW / DIN Reg. Nr. BMPi136985aPO/

17 Table of measure 140S - 730S Type S A A1 B B1 C C1 D EØ F F1 G H Ø J P Q

18 Technical data K - Type K = with ductwork Warm air heater for oil- or gas-firing. K-unit for connecting attachments and duct systems. Blow open to three sides, without cowl, with drive, switch box, thermostat, completely wired External outlet pressure Pa Typ VN (1,2/20 C) m³/h Motor kw Current consumpt A Lp db(a) Motor kw Current consumpt A Lp db(a) Motor kw Current consumpt A Lp db(a) Motor kw Current consumpt A Lp db(a) Motor kw Current consumpt A Lp db(a) 140 S ,5 3, ,2 5, ,2 5, ,2 5, ,0 6, S ,2 5, ,0 6, ,0 6, ,0 6, ,0 8, S ,2 5, ,2 5, ,0 6, ,0 6, ,0 8, S ,0 6, ,0 8, ,0 8, ,5 10, ,5 10, S ,0 6, ,0 8, ,5 10, ,5 10, ,5 15, S ,5 10, ,5 15, ,5 15, ,5 15, ,0 21, S ,5 10, ,5 15, ,5 15, ,5 15, ,0 21, S ,5 15, ,0 21, ,0 21, ,0 21, ,0 21, S ,5 10, ,5 15, ,0 21, ,0 21, ,0 21, S ,5 15, ,0 21, ,0 21, ,0 21, ,0 21, S ,0 21, ,0 21, ,0 28, ,0 28, ,0 28,50 86 These performances are achived by standard ventilators. 18

19 Attachments The air heaters for duct systems can be equipped or supplemented with the indicated attachments. The components are made of galvanised sheet metal. 1 Suction components 2 Blow components 3 Fixing elements false cover 105 suction grid (inserted in standard types according to air rate) 110 duct frame connection louver (at least necessary doublesided with automatic reversal) blow components 200 and 220 to 243 for connection to duct systems Exhaust gas componentns 310 stand frame 510 exhaust gas elbow 200 duct frame connection 320 wall console 520 exhaust gas pipe standard plenum for direct blowing 219 plenum base frame for floor 530 base frame for ceiling suspension exhaust gas cleaning tee 540 roof connection 130 flat filter 220 plenum to the long side 541 roof plate 135 cassette filter 221 plenum to the front Air supply elements 4 side for burner 542 rosette 140 fire lid 230 tee-cowl to the long side 400 burner casing 543 rain bowl 150 silencer 231 tee-cowl to the front side 410 suction elbow 160 wall socket 240 plenum to the top, long side 420 suction pipe 170 weather-protective grid 241 plenum to the top, front suction perts with 430 side screen (wall duct) 242 plenum to the top, square 440 roof duct 243 plenum to the top, rounded 441 roof plate 249 elbow 442 rosette 250 blow-off head 443 rain bowl 19

20 Warm air heater - attachments 1 suction components longsinde D + E alongside D + E fronts ide D + E The following suction components can be drilled afterwards. 100 = chapeau aveugle 105 = treillis d aspiration 120 = volet de jalousie 140 = fire lid 150 = silencer 160 = wall socket For the components a transitional form 115 has to be used. On the heaters side the duct connection frame will be used. The transitional form has to be adapted to the local measures and to the components. Measure 140 S 170 S 195 S 260 S 290 S 360 S 430 S 490 S 580 S 730 S A B F A B F

21 Warm air heater - attachments 1 suction attachments 135 Pocket air filter (suction) mea sure s [mm] A H 140 S 170 S 195 S 260 S 290 S 360 S 430 S 490 S fits to suction opening 580 S 650 S 730 S 140 Fire lid F 90 mea sure [mm] A H 140 S 170 S 195 S 260 S 290 S 360 S 430 S 490 S to be designed separately 580 S 650 S 730 S 150 silencer (suction) mea sure [mm] A H L 140 S 170 S 195 S 260 S 290 S 360 S 430 S 490 S 580 S 650 S 730 S to be designed separately these measures are based on the calculation of the required sound insulation 160 wall socket mea sure [mm] A H L 140 S 170 S 195 S 260 S 290 S 360 S 430 S 490 S 580 S 650 S 730 S to be designed separately based on the calculation th length depends on the wall s thickness, without further indication the length is 300 mm 170 weather protective grid mea sure [mm] A H L 140 S 170 S 195 S 260 S 290 S 360 S 430 S 490 S to be designed separately 580 S 650 S 730 S 21

22 Warm air heater - attachments 2 blow out accessories measure (mm) 140 S 170 S 195 S 260 S 290 S 360 S 430 S 490 S 580 S 650 S 730 S P Q Plenum for direct blowing (3-sided) Mea sures (mm) 140 S 170 S 195 S 260 S 290 S 360 S 430 S 490 S 580 S 650 S 730 S P Q R U duct bowl rounded Mea sure (mm) 140 S 170 S 195 S 260 S 290 S 360 S 430 S 490 S 580 S 650 S 730 S D Ø auf Anfrage Q P Plenum Mea sures (mm) 140 S 170 S 195 S 260 S 290 S 360 S P Q 935 R U 30 22

23 Warm air heater - attachments 4 Air supply elements for burner If the unit is used in motor workshop and garages, fresh air supply for the burner is a set condition. In other workshops and halls with bad air conditions, chlorine containing or dusty ambient air it is strongly recommended. Fresh air may be supplied through a roof or a wall. 400 Burner casing measure (mm) 140 S 170 S 195 S 260 S 290 S 360 S 430 S 490 S 580 S 650 S 730 S A B C D E F Profile SBM suction elbow 90 A Ø B C L suction elbow 45 A Ø B C L suction pipe A Ø B L suction parts with scree A Ø B L roof duct suction pipe Ø A Ø L roof plate suction pipe Ø A B Ø rosette suction pipe Ø A Ø B Ø L rain bow suction pipeø A Ø B Ø

24 Warm air heater - electric accessories Kroll day/night automatic control (electronic two-point controller) Instruction manual General description: The temperature controller IST with sensor RF-0 is used to control the temperature for general purpose. The operating range is C. The temperature in C can be regulated with two separate adjusting knobs, that are indicated by day and night. At which time periods the ranges day and night should apply, can be programmed by a weekly timer. This timer has got a reserve power of approx. 150 hours. The function of the temperature controller corresponds to a two-point controller. The switching hysteresis can be set between 0,2K and 1,2K. The trimmer P3 is accessible after opening the front cover and removing the front plate. The setting is to be executed by qualified electrical service personnel while the controller is voltage-free. The temperature controller IST is an electric sensor control unit and an independent control unit for assembly and fixed wiring, type X. There is no limitation of operating times. The operating mode is automatic with micro switch-off, type 1. B without sensor-failure-switch-off. With a sensor type RF-o, the controller works in a range of 0 up to 35 C, at a temperature variation speed of approx. 4 K/h and a (low) set switching hysteresis of approx. 0,2 K. The temperature variation speed depends on the characteristics of the other parts of the controlled system like heating load, cooling load, overload of the heater etc. The controller may be operated in polluted areas (IP 54). Putting into operation: Before putting the unit into operation, correct wiring and fixings of the wires are to be examined. By switching on the mains, e.g. by activating the fuse, the controller starts to operate. The switching hysteresis can be set between approx. 0,2 K and 1,2 K. The trimmer P3 is accessible after opening the front cover and removing the front plate. A description of the timer is enclosed. All indications concerning type EM/1 digi 16 without relay output are valid. The timer documentation informs about the setting on time and about how to program the switch-off (page 31 to 38). The information on page 34, paragraph 7, about the accumulator are valid accordingly, since there is one inserted in the controller. Operation: Corresponding to the programmed timer, the temperature is controlled according to the selected temperature set value day or night. Both set values can be selected separately within the limitation from 0 to 35 C The red control light indicates the operating mode of the controller. If it is switched on, the controller has demanded heating, which means that phase L is connected through to output L1 resp. the temperature set value is higher than the actual temperature as measured. Connection: The electric connections of IST are under the cover at the front side of the unit. Note! The unit is to be connected by a registered electrical specialist only. The instructions of the electricity supplier and the specific unit instructions are to be observed. 24

25 Warm air heater - electric accessories The sensor is linked with terminals 17 and 18. Mains and sensor leads are always to be separated by using different case openings. The sensor leads are laid through the outer right opening. They may be extended up to 50 m. In order to do this, a screened cable type LiYCY 2 x 0,5 is to be used. The screen must be put under terminal 18 on one side. Terminals 8 to 12 are not used, the zero potential N is on terminal 9 Technical data Timer: rated voltage: environmental conditions: electromagnetic compatibility: Protection: control function: switching hysteresis: switching output: signal indication: switching capacity of each output: temperature range: C 2 separate set ranges ( day, night ) time programming, switching between day and night with weekly timerrf-0 (resp. equivalent sensors : NTC; 2,5 k at 25 C) 1 N 230V/50Hz 0 C up to 50 C acc. to EN and EN IP 54 two-point-controller 0,2 1,2 K adjustable 1 open contact, potential-free incoming current = red light on 10(3)A 230 V measures of casing (HxWxD): 180x210x115mm 3 Note! The unit is to be connected by a registered electrical specialist only. The instructions of the electricity supplier and the specific unit instructions are to be observed. His unit is in accordance with the requirements of EN , EN for unlimited operation in industrial and residential areas. 25

26 Room thermostat Room thermostat RT Art No in plastic casing 71 x 71 x 30 mm breaking capacity heat 10(45) A Temperature range 6 30 C Switching capacity 0,5 K Protective system IP 30 Room thermostat - RTI industry type Art.-No plastic casing 105 x 94 x 65 mm breaking capacity 16 (3)A. at 230 V / 50 Hz Temperature range 0-40 C Switching capacity 2 K Protective system IP 54 AP Industry type Art.-No with covered temperature adjustment, according to Art.-No

27 Burner - assembly type 140 S 360 S 430 S 730 S C = at least 150 mm 210 mm The burner will be mounted on the front side of the unit with 4 flange screws. In each case the operating manual for the burner has to be respected! Concerning burners of other suppliers: installation is to be made corresponding to suppliers directives. The combustion chamber should not be over- or under loaded. Waste gas temperature should not be under 160 Kelvin over room temperature (condensate). In order to avoid condensates with 2-phase burners they should only be driven in under load during start. The instrument block of the burner is loosely enclosed ad has to be assembled on the site. Installation, gas connection and initial operation have to be made exclusively by specialists. The combustible flow should correspond to the heating power as ordered. The burner has to be adjusted in a way that the combustion chambers load is steady. The flame ends should not touch the back wall! Recommended die approach angle for oil burners is 60. The length of the fire tube X must at least achieve the dimensions C of the following table. It is recommended that the fire tube sticks into the combustion unit about mm. If necessary a fire tube extension is to be used. 27

28 Burner assembly Burner plate The bore for burner fixing are made in the middle of the burner plate and are predrilled corresponding to the following table. Other measures for diameter B and F only upon special request. Mea sure (mm) Type 140S- 360S 430S - 730S A B Ø F Ø M M8 M 10 Electric connection of the burner Kroll Warm air heaters are designed in a way that usually every tested burner brand can be used. It is connected via a rapid assembly plug-and-socket connection (230 V 7-polar) which is attached to the warm air heater. A permanent wiring is made from 3~ 400 V burners on. If burner is provided by customer, the connector plug (enclosed with each burner) for 230 V and for 400 V has to be installed according to circuit diagram. If burner is provided by customer always indicate if it is with 230 V a.c. or with 400 V three-phasemotor and send valid circuit diagram. A fixed wiring takes place from burner type 3 ~ 400 V. Fuel oil connection A sufficient fuel supply has to be guaranteed. The installation of the fuel oil supply has to be done by authorised experts according to the regulations for oil warm air heaters in your country. You must specially pay attention that the cross section of the line will be designed for the complete line resistance, the suction height and an increased viscosity in case of lower temperatures. If necessary a oil feeding aggregate has to be used. The suction pipe has to be supplied with a foot valve in the tank head. Attention! If external temperature is low, enough free-flowing oil has to be at burners disposal. Gas connection Corresponding to the units requirements, the necessary gas quantity and gas pressure always have to be obeyed. The installation of the gas connection has to be done by authorised experts after DIN 4756 or after DVGW-working sheet G 600 for gas fired warm air heaters, as well as the TRF for liquid gas. Gas pressure regulation apparatus and stop cocks has to be prepared on the part of the builder. The power cross section is designed on the base of gas connection, performance resistance and pre-pressure. Before initial operation gas lines have to be cleaned and checked. Exhaust of combustion gas The units have to be connected to an own chimney, steel or bricked. The chimney type has to be according to DIN part 1, the chimney measures according to DIN 4705 part 1 or part 2. For the optimum function of the fire place, the chimneys should be installed near the ridge and overlap this by minimum 0,5 meters. If amming velocity heads (e.g. by katabatic winds or because of buildings in the neighbourhood) are expected. In this case the dimension of the chimney should be correspond to this. Chimneys out of steel will normally be approved as exceptional case, if there are no fire protection considerations. The DIN 1298 is valid for the exhaust gas tube connectors between apparatus and chimney. The connectors should not be longer than 2 meters. The exhaust gas connection has generally to be installed on approved chimneys. The chimneys can be bricked or made of metal. 28

29 Setting into operation fan motor 1.Checking the drive Check fan direction of rotation, watch directional marker at fan box. Check priming of driving belt. Check if fixing bolts of complete drive are screwed up. 2. rated current measure current consumption To avoid incorrect measures, all provided suction- or blind sheets have to be mounted on apparatus and the grille screens in the air channel and in the blowing out hood have to be opened. The existing system voltage has to be checked. a) Direct start The measured rated current (ampere) may not exceed the value given on the motor type plate. Thermally adjust overload relay according to rated current of motor. b) Y/ - start The measured rated current (ampere) may not exceed the value given on the motor type plate. Multiply rated current of motor with factor 0,58 and the thermally adjust overload relay according to calculated value. To avoid errors of measurement, each phase should be measured separately. 3. Thermally overload relay By removing a safety fuse the function of the overload relay or is control value can be checked. In orderly function resp. adjustment the relay should release after about 30 seconds. 4. When charging current consumption is too high If the motor takes up too much current although the electrical connection is done orderly and the voltage supply is sufficient, the thermally over current release must not no account be set higher and it must not be bridged. For remedy the air suction and the air outlet (eventually duct compression) have to be checked. Remedial measures have to be taken. First starting The first starting of the unit and its blowpipe have to be done by the manufacturer or by another expert who is authorised by the manufacturer. Doing this the function and the correct adjustment of all control, regulating- and safety devices have to be checked. - Check all screws and nuts of the fan- and burner fastening are jammed tight. - Check voltage of driving belt.. - If need be, open the out-blow grating and adjust it according to the requirement. - Check the adjustments on triple combination regulator (burner 75 C, fan 45 C) - Switch on the build-laterally main switch/ fuse - Check fan direction of rotation (operating switch in position: ventilation ) - Adjust room thermostats higher than actual room temperature. - Open fuel supply - Operating switch in position heating. CAUTION! After the first 40 running hours in heating operation the screws of the cleaning cover at the radiator as well as the screws of the connecting flange between the combustion chamber and the heat exchanger have to be checked and, if need be, tighten up. Therefor the case cleaning cover above the burner has to be opened. This control has also be done at each regular service. 29

30 Setting into operation fan motor The fuel oil resp. the gas throughput (of a unit) has to be adjusted according to the thermal stress of the unit (watch unit type plate). The burner has to be adjusted according to the producer s data to optimum values, but minimum to those of the Bundes-Immissionsschutzgesetzes BImSchG. The chimney draft has to be measured in cold and warm condition (watch also page 9). To avoid (the danger of) falling below of the point condensation and (out of this) the resulting corrosion in the heat exchanger, the exhaust gas temperature-difference ( /t ) from 160 Kelvin must not be fallen below. The first start up must only be done by authorised personal. A measuring report has to be done and handed over to the operator for keeping! The operator has to be intimated with the unit! Heating - Switch on the build-laterally main switch/ fuse - Open fuel supply - Set operating switch in position heating. - Adjust room thermostats on wished room temperature. In case of heat requirement, the blowpipe switches on itself automatically. The supply air fan won t be switched on until desired temperature has been reached. Doing this you avoid the out blow of cold air. Now the unit works fully automatic according to the desired room temperature. Ventilation Set operating switch in position: ventilation Unit works as permanence ventilation. A thermostatic regulation is not possible Turning off Set operating switch in position: 0 The supply air fan keeps running for cooling the heat exchanger. Until final turning off it can start up several times. Never switch off the unit at the main- or emergency switch before the whole operating sequence of the re-cool phase (except in an emergency). In case of a longer lasting interruption of operation, the build-laterally main switch resp. the fuse should be switched off after the turning off and the fuel supply should be shut off. 30

31 Cone belt exchange Dismount V-belt pulley - Release the tension of the V-belt and take it off - Turn out the inner-hexagon cap screw (watch figure 1) - Tap a screw into the tapped hole of the socket and screw it up. - The socket will be detached in tightening the screw. - The loosen pulley can now be pulled off the shaft. fig. 1 Mount V-belt pulley - After cleaning and degreasing the pulleys and the socket will be set into each. The holes must cover each other, then you can tap in the inner-hexagon cap screw. - Push pulley and socket on the shaft and align them. - Motor and fan pulley have to align exactly. - The inner-hexagon cap screws are tightened at the same time (fig. 2). fig. 2 31

32 Tension V-belts Before initial start up, as well as in regular intervals and at the services, the V-belt s situation and its tight fit. Eventually the V-belt has to be adjusted resp. exchanged. 1.) Adjustment of V-belt between motor and fan - Loosen the 4 screws at the side a bit (A), but do not screw them out totally. - Pull the Motor saddle with both screws at the front side (B) away from the fan. Doing this, the V-belt will be stretched. - Tighten up gain the screws at the side (A). 2.) Adjustment of V-belt between the fans - The V-belt will be tensioned automatically with a drive belt (C). - When required engage the spring into another hole. 32

33 Assembly of suck and pressure side accessories 1.) Attachment of conduit (pressure side) The attachment of pressure side accessories has to be done by self-tapping screws in the top unit edge. A jointing ring has to be put between the accessory and the unit. 2.) Attachment of suck side accessories Assembly of accessories 1. Lay the jointing ring between bonnet and unit (1) 2. Fix the bonnet at the case frame with self-tapping screws (2), e. c. 5,5 x 19 mm). A fixing in the edges is not possible. The fixing of the accessories has to be done identically The attachment of suck side ordered accessories has to be done by self-tapped screws in the unit edges (put on). Between the accessory and the unit you have to lay a jointing ring View View on top 3.) Conversion of the unit from upright to horizontal operation: - fix the base frame to the heater - mount the chains on the eyebolt of the heat exchanger - incline the unit with a suitable device over the base frame into horizontal poisiton 33

34 Accessories 01 Ventilator 02 Driving motor 03 Motor pulley 04 V-belt 05 Fan pulley 06 Combustion chamber 07 Heat exchanger 08 Exhaust-gas whirls 09 Seal for combustion chamber 10 Seal for burner plate 11 Seal for heat exchanger 12 Seal - cleaning cap 13 Socket for sight glass 14 Seal sight glass 15 Thermostat 16 Burner plate 34

35 Switch box For motor performances up to 3,0 kw the switch box is mounted to the unit. Type with selector switch heat - zero - ventilate. Thermostat is mounted to the unit separately at the front or long side. From October 2001 on, the three separate thermostats will be mounted with the switch box. If filter control is necessary, external thermostats will be used due to space saving. For motor performances from 4,0 kw on, the switch box is always mounted outside to the unit, front or long side. This type also has selector switch heat - zero - ventilate. Thermostat also always mounted outside to the unit, front or long side Upon request and for extra price the switch box can also be delivered for wall-mounting. Switch box to choose separate - for extra charge In this case an additional clamp box will be installed and wired at the unit. Specific switch boxes of each kind upon request for special price Three-way thermostat Clamp box Switch box separate 35

36 Cicuit diagram 140S S 36

37 Cicuit diagram 290 S S 37

38 Cicuit diagram 490 S S 38

39 Cicuit diagram 490 S S (Page. 2) 39

40 Cicuit diagram burner level 2 40

41 EG Konformitätserklärung EG Declaration of conformity EG Déclaration de conformité Der Hersteller The manufacturer / Le fabricant Dokumentationsbevollmächtigter Authorized person for documentation Personne authorisée pour la documentation Kroll GmbH Pfarrgartenstraße 46, D Kirchberg Tel /830-0 Josef Cuntz erklärt hiermit, dass folgende Produkte / Herewith declares that the following products Explique par ce document que les produits suivants Produktbezeichnung Description / Désignation du produit Typenbezeichnung / Type / Type Stationäre Warmlufterzeuger Stationary air heaters / Générateur d air chaud stationaire 140S 730S allen einschlägigen Bestimmungen der folgenden Richtlinien entspricht correspond to all relevant regulations of the following guidelines Correspondent à tous les spécifications des directives suivantes 2006/42/EG 2006/95/EG Maschinen Machines / Machines Elektrische Betriebsmittel zur Verwendung innerhalb bestimmter Spannungsgrenzen Electrical devices for use within certain voltage limits Matériel électrique pour utilisation dans certaines limites de voltage 2004/108/EG Elektromagnetische Verträglichkeit Electromagnetic compatibility Compatibilité électromagnetique 2009/142/EG Gasverbrauchseinrichtungen / Gas appliances directives / Directives de gaz Folgende harmonisierte Normen wurden angewandt The following harmonized norms have been applied Les normes harmonisées suivantes ont été appliquées EN EN 1020-A1:2001 Kirchberg, Alfred Schmid Geschäftsführer / Director / Directeur 41

42 Garantie request Kroll UK Azura Close, Unit 49 Woolsbridge Industrail Estate Dorset - Wimborne BH 216 SZ Three Legged Cross We have received the following Kroll-space heater/heating system, which has been installed by the heating contractor listed below.. Type Our address (user) Serial-No. Our heating contractor (installer) Telephone The following person in our firm is responsible for the operating and servicing : We are interested in taking out a service contract on the appliance. Please send us further information Telephone We have been fully instructed in the operation of the appliance or system. We have been given the operating instructions. Please send us the guarantee certificate. Mr. To be filled in by the user Place Date User s signature and stamp Oil Gas Combined Oil/Gas Burner installed Manufacturer Type No. Oil burner Gas burner Nozzle type and Oil flow Excess Type of Gas Flow Flow pressure nozzle Gas consumption number rate pressure gas nozzle pressure pump filter inlet l/h bar mbar mbar m³/h 1 st level 2 nd level 1 st level 2 nd level 1 st level 2 nd level Test data Heat load Q B kw Burner Inlet temperature C Flue Gas temperature C Burner adjusted an set into operation on: Appliance installed: CO 2 in Boiler room Flue gas losses % By: Soot level Bacharach scale Heating Efficiency Q N kw in the space to be heated free Air quantity m³/h Mean air Outlet temperature attached to duct system of length approx. The space heater / heating system has been installed and set into operation in accordance with the installation and operating instructions. The customer has been fully instructed in the servicing and operation. C Power consumption Fan motor A/phase To be filled in by skilled work shop Date of delivery / installation Checked by after sales service Signature and stamp of heating contractor on : 42

43 Servicing intervals Day of servicing Name Notes 43

44 Bei nicht bestimmungsgemäßer Verwendung, Aufstellung, Wartung, wie in der Betriebsanleitung vorgegeben oder eigenmächtigen Änderungen an der werkseitig gelieferten Geräteausführung erlischt jeglicher Gewährleistungsanspruch. Im Übrigen gelten unsere Verkaufs- und Lieferbedingungen Technische Änderungen im Sinne der Produktverbesserung vorbehalten. Any use, installation, maintenance that is not effected according to the rules as asserted in the technical manual, or unauthorized modifications on the original version as delivered from manufacturer leads to expiration of any right to warranty. Furtheron our Conditions of Sales and Delivery are valid. Technical modification for product improvement are subject to change without notice. Toute utilisation, installation et maintenance qui ne soit pas effectué conformément aux directives fixés dans le manuel technique, ainsi que toute modification à l appareil livré du fabricant dans sa version originale, entraîne l expiration du droit de garantie. En plus, nos Conditions de vente et de livraison sont en vigueur. Sous réserve de modification technique dans le sens d amélioration du produit. Kroll GmbH Pfarrgartenstraße 46 D Kirchberg/Murr Telefon (0049) / Telefax (0049) / vertrieb@kroll.de Internet Service Hotline (0049) / Kroll UK Ltd. UK & Ireland Subsidiary BJ 21 6SZ Wimborne-Dorset Great Britain Phone (0044) Fax (0044) mail@krolluk.com Internet Kroll France SA au capital de HT RCS Villefranche / Saône Tarare B APE 516 A TVA N Telefon (0049) / Telefax (0049) / france.kroll@kroll.de Internet

Operating Instructions

Operating Instructions Dehumidifier Operating Instructions Stand July 2011 057908 Art.-Nr.: 046543-01 IMPORTANT Before using this appliance for the first time, read the instruction manual carefully and keep it safe for future

More information

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80 IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80 EN OPERATING MANUAL OIL HEATER TRT-BA-IDE20-30-50-60-80-TC-001-EN Table of contents Information on the use of this manual... 1 Scope of delivery... 1 General safety...

More information

Installation and maintenance manual

Installation and maintenance manual Installation and maintenance manual Warm air heater WS/WO (Copy of the original version) Wolf GmbH D-84048 Mainburg Postfach 1380 Telefon +498751/74-0 Telefax +498751/741600 Internet: www.wolf-heiztechnik.de

More information

VETO CLEANER 500 FLUE GAS CLEANER

VETO CLEANER 500 FLUE GAS CLEANER As of serial number 3100 0001 VETO CLEANER 500 FLUE GAS CLEANER USER MANUAL SPARE PARTS LIST Manufacturer: ALA TALKKARI Veljekset Ala-Talkkari Oy FI-62130 HELLANMAA TEL. +358 6 433 6333 FAX +358 6 437

More information

AirUnit. Installation instructions. mfh systems modern floor heating. Decentralised domestic ventilation

AirUnit. Installation instructions. mfh systems modern floor heating. Decentralised domestic ventilation mfh systems modern floor heating AirUnit Decentralised domestic ventilation Installation instructions List of contents, Installation instructions Page 1. General information... 03 2. Function / planning

More information

Light oil / kerosene burner

Light oil / kerosene burner Installation, use and maintenance instructions Light oil / kerosene burner One stage operation CODE MODEL TYPE 374445 G5 444T50 290238 (5) - 05/20 TECHNICAL DATA Thermal power output 28 60 kw 2.3 5 kg/h

More information

Guide book ASPIMAX 32. Im Geer 20, Isselburg. Type No.: 403. Serial No.:...

Guide book ASPIMAX 32. Im Geer 20, Isselburg. Type No.: 403. Serial No.:... ASPIMAX 32 Manufacturer: deconta GmbH Im Geer 20, 46419 Isselburg Type No.: 403 Serial No.:... Index On page 1 Basic safety advices 3 2 Technical description 4 2.1 Operating mode separator Filter system

More information

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART # INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #238-39387-00 THIS INSTRUCTION SUPPLEMENT IS ONLY INTENDED TO GIVE INSTALLATION INSTRUCTIONS AND INFORMATION RELATED TO THE INDUCED

More information

VIESMANN. Service instructions VITOLADENS 300-T. for contractors. Vitoladens 300-T Type VW3B Inox-Radial heat exchanger for oil fired condensing Unit

VIESMANN. Service instructions VITOLADENS 300-T. for contractors. Vitoladens 300-T Type VW3B Inox-Radial heat exchanger for oil fired condensing Unit Service instructions for contractors VIESMANN Vitoladens 300-T Type VW3B Inox-Radial heat exchanger for oil fired condensing Unit VITOLADENS 300-T 1/2007 Please keep safe. Safety instructions Safety instructions

More information

VIESMANN. Service instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

VIESMANN. Service instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler Service instructions for contractors VIESMANN Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler For applicability, see the last page VITORONDENS 200-T 6/2011 Please keep safe. Safety

More information

Light oil burners. One stage operation

Light oil burners. One stage operation Installation, use and maintenance instructions Light oil burners One stage operation CODE MODEL TYPE 3505 RDB CF 38 50 T3 350050 RDBR CF 6 50 TR 35050 RDBR CF 33 50 TR 35050 RDBR CF 38 50 T3R 350650 RDBR

More information

Installation and maintenance instructions

Installation and maintenance instructions 6304 4995 0/004 GB For installer Installation and maintenance instructions Flue gas heat exchanger WT50/60 Please read thoroughly prior to installation and maintenance. Summary About this manual This equipment

More information

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59 SOUND-INSULATED FAN OPERATION MANUAL _v.1(2)-en.indd 1 10.08.2015 15:20:59 CONTENT Introduction 3 General 3 Safety rules 3 Transport and storage requirements 3 Manufacturer's warranty 3 Fan design 4 Delivery

More information

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL Heating, Air Conditioning, Ventilation Отопление-Кондиционеры-Вентиляция MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL 1. Usage MTM 8-30 universal oil heater is designed for heating commercial rooms

More information

Instruction manual for downdraft hood

Instruction manual for downdraft hood Instruction manual for downdraft hood Model code: BODY / DD600BK - BODY / DD900BK BODY / DD600SS - BODY / DD900SS Contact Caple on 0844 800 3830 or for spare parts www.4caple.co.uk The symbol on the product

More information

REMKO CLK Mobile automatic heater

REMKO CLK Mobile automatic heater REMKO CLK Mobile automatic heater Operation Technology Spare Parts Edition GB M04 REMKO - powerful like a bear. Operating Instructions Read these instructions carefully before setting up/operating the

More information

Manual. Atomizer Air Humidifiers. Type DG4 / DG8

Manual. Atomizer Air Humidifiers. Type DG4 / DG8 Manual Atomizer Air Humidifiers Type DG4 / DG8 1.. Instructions... 2 1.1. Operational Safety notes... 2 1.2. Transport... 2 1.3. Technical data... 3 1.4. Schematic diagram... 4 1.5. Description of Operation...

More information

Synergy Grill User & Engineer Installation & Conversion Guide

Synergy Grill User & Engineer Installation & Conversion Guide Synergy Grill 1300 User & Engineer Installation & Conversion Guide 1 Index: Description Page Number/Section Important Information 3 Installation 4-6 / Section 1 Commissioning 6 / Section 2 Converting Gas

More information

Light oil - kerosene burner

Light oil - kerosene burner Installation, use and maintenance instructions Light oil - kerosene burner One stage operation CODE MODEL TYPE 374374 G3B 437T 90 (4) - 05/0 TECHNICAL FEATURES TYPE 437T Thermal power output 9 35 kw.6

More information

IONTO-COMED INSTRUCTION MANUAL IONTO-COMFORT XDREAM BED

IONTO-COMED INSTRUCTION MANUAL IONTO-COMFORT XDREAM BED IONTO-COMED INSTRUCTION MANUAL IONTO-COMFORT XDREAM BED Art. No. 8461, 8461.5 Contents Safety Instructions...3 Fields of Use...4 Control Elements and Connections...4 Installation...5 Operation...7 Set

More information

Propane Heater REMKO PGM 30 REMKO PGM 60

Propane Heater REMKO PGM 30 REMKO PGM 60 Propane Heater REMKO PGM 30 REMKO PGM 60 Operation Technology Spare Parts Edition GB L07 REMKO strong as a bear. Operating instructions Make sure to read these instructions carefully before starting/using

More information

Installation Instructions Dual Fuel Ranges

Installation Instructions Dual Fuel Ranges Installation Instructions Dual Fuel Ranges E30DF74EPS E36DF76EPS E48DF76EPS 5995447082 2 Safety IMPORTANT SAFETY INSTRUCTIONS Safety Precautions Do not attempt to install or operate your unit until you

More information

Remeha. Fuel oil/gas boilers P 520. Installation and Service Manual A

Remeha. Fuel oil/gas boilers P 520. Installation and Service Manual A Remeha Fuel oil/gas boilers EN Installation and Service Manual 300016859-001-A 63115 Declaration of conformity The appliance complies with the standard model described in declaration of compliance. It

More information

Operating Instructions

Operating Instructions Operating Instructions Typ TEKA CAREMASTER TEKA Absaug- und Entsorgungstechnologie GmbH Industriestraße 13 D-46342 Velen Postfach 1137 D-46334 Velen Tel.: +49 (0) 2863 9282-0 Fax: +49 (0) 2863 9282-72

More information

RS Chimney Fan For Gas & Oil Applications. Installation & Operating Manual USA CAN

RS Chimney Fan For Gas & Oil Applications. Installation & Operating Manual USA CAN Installation & Operating Manual 3000270 10.01 USA CAN RS Chimney Fan For Gas & Oil Applications 1200 Northmeadow Parkway, STE 180 Roswell, GA 30076 (770) 587-3238 (800) 255-2923 Fax (770) 587-4731 info@exhausto.com

More information

FLAME115 INFRARED HEATER SERVICE MANUAL INDEX FIRE 115 WARNING

FLAME115 INFRARED HEATER SERVICE MANUAL INDEX FIRE 115 WARNING FLAME115 INFRARED HEATER SERVICE MANUAL INDEX 1. CONTROLS AND COMPONENTS 2. FLAME CONTROL CYCLES 3. MAINTENANCE SCHEDULE 4. TROUBLESHOOTING GUIDE 5. REPAIR PROCEDURES 1. FAN MOTOR ASSEMBLY 2. FUEL FILTER

More information

UV Flame Supervision System

UV Flame Supervision System 7 783 UV Flame Supervision System DETACTOGYR LFE50 Series 02 ISO 9001 The LFE50 is a self-checking UV flame supervision system designed for use with continuously operating burners or for burners running

More information

Installation & Maintenance Manual

Installation & Maintenance Manual Installation & Maintenance Manual MOL 200 S1L (B30A) Oil Burner 11/12 Tel: +44 (0) 1905 794331 Fax: +44 (0) 1905 794017 Email: info@nu-way.co.uk Web: www.nu-way.co.uk DESCRIPTION COMPONENTS 1. Shrouded

More information

Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro

Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro 2006/01 Content Important Information 1. Notes... 3 1.1 CE - Labeling... 3 1.2

More information

M LLET. Silo pressure detector. Füllstandtechnik. Operating instructions. 1. Description. 1.5 Dimensions. 1.1 Intended use. 1.

M LLET. Silo pressure detector. Füllstandtechnik. Operating instructions. 1. Description. 1.5 Dimensions. 1.1 Intended use. 1. Operating instructions 1. Description 1.1 Intended use The pressure detector controls as limit switch the overpressure in silos and vessels. 1.5 Dimensions 1.2 Function If the pressure reaches the switching

More information

5KW ELECTRIC FAN HEATER

5KW ELECTRIC FAN HEATER 5KW ELECTRIC FAN HEATER MODEL NO: DEVIL 7005 PART NO: 6935452 OPERATION & MAINTENANCE INSTRUCTIONS LS0615 INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting to use this product,

More information

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A cod. 6272262A GENERAL DATA Heating Data Heat Output Input (Adjustable) (Adjustable) Format 34i 11.2 34KW 45 145MJ/hr Format 34e 11.2 34KW 45 145MJ/hr General Specifications FORMAT 34i 34e Main burner injectors

More information

Parts Available from

Parts Available from Montage und Bedienungsanleitung Manuel d entretien Installation, use and maintenance instructions Installatie-, gebruiks- en onderhoudsvoorschriften Oδηγίες εγκατάστασης, χρήσης και συντήρησης D F GB NL

More information

1 VICTRIX ZEUS Superior kw I features

1 VICTRIX ZEUS Superior kw I features Wall-hung condensing VICTRIX ZEUS Superior kw I is the new range of wall-hung condensing boilers with 54 litre stainless steel storage tank available in two versions with nominal heat output of 26 kw and

More information

Installation of a Brunner fireplace. General Indications

Installation of a Brunner fireplace. General Indications Installation of a Brunner fireplace General Indications CONTENTS 1 Basic informations...3 2 Safety precautions...4 3 Combustion air...5 4 Requirements for location... 6 5 Overview of fire safety and heat

More information

and Installation Instructions The installation instructions for the Unit pressure jet oil burner is included in the pressure jet oil burner pack.

and Installation Instructions The installation instructions for the Unit pressure jet oil burner is included in the pressure jet oil burner pack. Technical Guide and Installation Instructions MKS / MUS Steel boiler 70-550 kw The installation instructions for the Unit pressure jet oil burner is included in the pressure jet oil burner pack. The control

More information

VIESMANN. Installation instructions VITOMAX 200-HW. for contractors

VIESMANN. Installation instructions VITOMAX 200-HW. for contractors Installation instructions for contractors VIESMANN Vitomax 200-HW Type M238 Oil/gas fired high pressure hot water boiler Combustion output 4.0 to 18.2 MW VITOMAX 200-HW 6/2007 Dispose after installation.

More information

2.8KW ELECTRIC FAN HEATER

2.8KW ELECTRIC FAN HEATER 2.8KW ELECTRIC FAN HEATER MODEL NO: DEVIL 2800 PART NO: 6925800 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC0817 INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting

More information

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS INSTRUCTIONS FOR: INFRARED IP55 HEATER MODEL:- QZWP45N Thank you for purchasing a Consort Claudgen product. Manufactured to a high standard this product will, if used according to these instructions and

More information

POWER VENTER SYSTEM. Model: PVO-300, PVO-600

POWER VENTER SYSTEM. Model: PVO-300, PVO-600 POWER VENTER SYSTEM Model: PVO-300, PVO-600 Included is one ETL and cetl listed Power Venter to be used primarily with a single 120VAC controlled oil fired furnace, boiler, or water heater. The PVO may

More information

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20 INSTALLATION, OPERATION AND MAINTENANCE Ariterm Hybrid 20 TABLE OF CONTENTS General...3 Installation... 4-5 Dimensions - with flue gas exhauster...6 Dimensions - without flue gas exhauster...7 Pipe installations...8

More information

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28 The competent brand for energy saving systems NEW Gas-combi boiler CGG-1K-24/28 Gas-combi boiler CGG-1K Technical data room sealed fannned flue model gas combi boiler for low temperature heating and d.h.w.

More information

This label warns for risk of electrical shock when failing to observe.

This label warns for risk of electrical shock when failing to observe. MANUAL horizontal centrifugal pumps MB series ic drive SB series mechanical seal 1. Introduction 2. Safety precautions 3. Receipt 4. Installation / Operation and Maintenance 4.1 Installation 4.2 Operation

More information

Direct Fired Heater Model AD Specification

Direct Fired Heater Model AD Specification Direct Fired Heater Model AD Specification Description A Direct-fired gas heating and ventilating unit(s), as indicated on the drawings shall be furnished. Unit(s) shall be tested in accordance with ANSI

More information

VIESMANN. Installation instructions VITOCROSSAL 200. for contractors. Vitocrossal 200 Type CM2 Gas fired condensing boiler with MatriX radiant burner

VIESMANN. Installation instructions VITOCROSSAL 200. for contractors. Vitocrossal 200 Type CM2 Gas fired condensing boiler with MatriX radiant burner Installation instructions for contractors VIESMANN Vitocrossal 200 Type CM2 Gas fired condensing boiler with MatriX radiant burner VITOCROSSAL 200 2/2007 Dispose after installation. Safety instructions

More information

Installation and Maintenance Manual Please retain this manual for future reference.

Installation and Maintenance Manual Please retain this manual for future reference. 342 N. Co. Rd. 400 East Valparaiso, IN 46383 219-464-8818 Fax 219-462-7985 www.heatwagon.com Installation and Maintenance Manual Please retain this manual for future reference. Electric Construction Heaters

More information

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE 2 GLEC-6 - Installation and maintenance CONTENTS 1 Important information... 3 2 Safety notes... 3 3 Technical description...4 4 Transport... 6 5

More information

Installation & Service Instructions for Jackson & Church Flexaire Packaged Furnaces SDF-125 thru SDF-400 Gas Firing

Installation & Service Instructions for Jackson & Church Flexaire Packaged Furnaces SDF-125 thru SDF-400 Gas Firing Installation & Service Instructions for Jackson & Church Flexaire Packaged Furnaces SDF-125 thru SDF-400 Gas Firing Important: To protect the unit and avoid damage to the heat exchanger, the blower speed

More information

30KW ELECTRIC FAN HEATER

30KW ELECTRIC FAN HEATER 30KW ELECTRIC FAN HEATER MODEL NO: DEVIL 7030 PART NO: 6935458 OPERATION & MAINTENANCE INSTRUCTIONS LS0615 INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting to use this product,

More information

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR 7 783 DETACTOGYR Flame Safeguard The... together with the QRA50M / QRA51M form a self-checking flame supervision system (DETACTOGYR ) designed for use with continuously operating oil or gas burners or

More information

LEIHDC70SC - LEIHDC70BB LEIHDC70BC. Instructions Manual.

LEIHDC70SC - LEIHDC70BB LEIHDC70BC. Instructions Manual. LEIHDC70SC - LEIHDC70BB LEIHDC70BC Instructions Manual www.rangemaster.co.uk INDEX EN RECOMMENDATIONS AND SUGGESTIONS...3 CHARACTERISTICS...4 INSTALLATION...5 USE...8 MAINTENANCE...9 2 RECOMMENDATIONS

More information

Grant Spira 6-26kW and 9-36kW Wood Pellet Boilers

Grant Spira 6-26kW and 9-36kW Wood Pellet Boilers ADDENDUM to INSTALLATION INSTRUCTIONS for Grant Spira 6-26kW and 9-36kW Wood Pellet Boilers DOC42-01/02 Rev03 - December 2014 ATTENTION INSTALLERS - UPDATED INFORMATION! The Grant Spira condensing wood

More information

INDEX RECOMMENDATIONS AND SUGGESTIONS... 4 CHARACTERISTICS... 5 INSTALLATION... 6 USE... 9 MAINTENANCE... 11

INDEX RECOMMENDATIONS AND SUGGESTIONS... 4 CHARACTERISTICS... 5 INSTALLATION... 6 USE... 9 MAINTENANCE... 11 INDEX EN RECOMMENDATIONS AND SUGGESTIONS... 4 CHARACTERISTICS... 5 INSTALLATION... 6 USE... 9 MAINTENANCE... 11 2 RECOMMENDATIONS AND SUGGESTIONS The Instructions for Use apply to several versions of this

More information

Oil burners Brûleurs fioul Stookoliebranders

Oil burners Brûleurs fioul Stookoliebranders Installation, use and maintenance instructions Manuel d entretien Installatie-, gebruiks- en onderhoudsvoorschriften GB F NL Oil burners Brûleurs fioul Stookoliebranders One stage operation Fonctionnement

More information

15KW ELECTRIC FAN HEATER

15KW ELECTRIC FAN HEATER 15KW ELECTRIC FAN HEATER MODEL NO: DEVIL 7015 PART NO: 6935456 OPERATION & MAINTENANCE INSTRUCTIONS LS0615 INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting to use this product,

More information

R e m e h a P Technical Information. Remeha P 300. Pressurized boiler. Heat output: kw

R e m e h a P Technical Information. Remeha P 300. Pressurized boiler. Heat output: kw Technical Information Remeha P 300 R e m e h a P 3 0 0 Pressurized boiler Heat output: 278-709 kw Remeha P 300 CONTENTS Preface 3 1 Description of the unit 3 1.1 General 3 1.2 Burners 3 2 Construction

More information

BENSON LINEAR RADIANT TUBE

BENSON LINEAR RADIANT TUBE BENSON LINEAR RADIANT TUBE Natural or Propane (Gas fired) I N S T A L L A T I O N C O M M I S S I O N I N G S E R V I C I N G U S E R I N S T R U C T I O N S September 2001 CONTENTS Page Compliance Notices

More information

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Internal ridged board 1 x 1.5 foil face installation shall be installed on roof, walls and base of casing. A-D WITH MPU SPECIFICATION WRITTEN SPECIFICATION Description A Modular Packaged Heating, Cooling and ventilating unit(s), as indicated on the drawings shall be furnished. Direct Fired Gas Unit(s) shall

More information

TermEfekt USER S MANUAL AIR HEATER. Model PGA 14

TermEfekt USER S MANUAL AIR HEATER. Model PGA 14 Przedsiębiorstwo Produkcyjno-Wdrożeniowe ARAJ sp. z o.o. 55-080 Kąty Wrocławskie, ul. Mireckiego 30 POLAND USER S MANUAL AIR HEATER TermEfekt Model PGA 14 Kąty Wrocławskie, 2004 Product identification

More information

Technical information. Remeha P200. Pressurized boiler. Heat output: kw

Technical information. Remeha P200. Pressurized boiler. Heat output: kw Technical information Remeha P200 R e m e h a P 2 0 0 Pressurized boiler Heat output: 59-256 kw Remeha P 200 CONTENTS Preface 3 1. Description of the unit 4 1.1 General 4 1.2 Burners 4 2. Construction

More information

MHG201 Gas Hob Manual for Installation, Use and Maintenance

MHG201 Gas Hob Manual for Installation, Use and Maintenance MHG201 Gas Hob Manual for Installation, Use and Maintenance 1 Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer.care@cda.eu

More information

breeze easytm model # F100-1W

breeze easytm model # F100-1W DewStop breeze easytm model # F100-1W Installation Guide Read and Save These Instructions LISTED Questions, Problems, Missing Parts? Please Call 1-360-876-2974 or E-Mail info@dewstop.com please retain

More information

CODE MODEL TYPE PRESS 60 N 616 T PRESS 60 N 616 T80

CODE MODEL TYPE PRESS 60 N 616 T PRESS 60 N 616 T80 Installation, use and maintenance instructions Heavy oil burner CODE MODEL TYPE 3434985 PRESS 60 N 616 T80 3434986 PRESS 60 N 616 T80 291 (2) - 01/2009 Thermal power - Output Operation Fuel Electrical

More information

INSTALLATION AND OPERATING INSTRUCTIONS General operating instructions for sample gas conditioner Model: MAK 6

INSTALLATION AND OPERATING INSTRUCTIONS General operating instructions for sample gas conditioner Model: MAK 6 List of contents 1.0 Uses 2.0 Technical data 2.1 Operating data 2.2 Construction and installation 2.3 Climatic load 2.4 Power supply 3.0 Function and design 3.1 General comments 3.2 Design 3.3 Performance

More information

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL CONTENT 3 Introduction 3 General 3 Safety rules 3 Storage and transportation rules 3 Manufacturer s warranty 4 Fan design 4 Delivery set 5 Technical data

More information

Approved in a thousand ways and indestructible: the mobile warm air heaters from Kroll

Approved in a thousand ways and indestructible: the mobile warm air heaters from Kroll Approved in a thousand ways and indestructible: the mobile warm air heaters from Kroll You will find the suitable heater for every request: The power range goes from 22 kw to 173 kw. The Kroll mobile warm

More information

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS CORR/GUARD INSTALLATION INSTRUCTIONS This symbol on the nameplate means this product is listed by Underwriters Laboratories Inc. Tested to UL1738 / CAN / ULCS636-08 Listing No. MH26687 Testing No. 11EN

More information

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60 HG 675 X 60 HG 675 CX 60 HG 675 CN 60 HG 675 CW 60 1 2 1. : 93/68: 90/396: 2006/95/CE: 2004/108/CE: - 1935/2004:. 2002/95/CE: RoHS 2.,.,,,,...,. (,..)..,,.,. ( ),,, ;,,.,.....,.,,,,,,...,. (..),,.,..,.,,,,

More information

Operating and Installation Instructions for CRAMER COE Gas Cooker

Operating and Installation Instructions for CRAMER COE Gas Cooker Operating and Installation Instructions for CRAMER COE Gas Cooker Models: COE-C COE-CG COE-CGO COE-FULL COE-C-DUFU COE-CG-DUFU COE-CGO-DUFU COE-FULL-DUFU Cooker (4 gas burners) Cooker + grill (4 gas burners)

More information

ELECTRIC AIR HEATER INSTALLATION AND SERVICE MANUAL

ELECTRIC AIR HEATER INSTALLATION AND SERVICE MANUAL ELECTRIC AIR HEATER INSTALLATION AND SERVICE MANUAL BC(E) SERIES INDOOR / OUTDOOR MANUFACTURED BY GENERAL INFORMATION PROJECT: ADDRESS: MODEL: SERIAL NUMBER: INSTALLER: ADDRESS: TELEPHONE: INSTALLATION

More information

Installation and maintenance instructions

Installation and maintenance instructions 6304 4994 03/2006 GB For installer Installation and maintenance instructions Flue gas heat exchanger WT30/40 Please read thoroughly prior to installation and maintenance. Contents Contents Contents 2 1

More information

Technology for life. Unit heater LH

Technology for life. Unit heater LH Technology for life. Unit heater 1 2 Contents Contents... Page Basic unit: casing, fan, motors... 4 Basic unit: heat exchanger... 5 Performance tables 25...6-7 Performance tables 40...8-9 Performance tables

More information

Oil burners fuel unit with solenoid valve

Oil burners fuel unit with solenoid valve Oil burners fuel unit with solenoid valve Type VM www.deltapumps.com VM1 - VM4U flanged Certified Quality System Printed in Germany VM_e.pdf - 18.05.08 Page 1/6 Oil burners fuel unit with solenoid valve

More information

Smoke extraction duct of sheet steel

Smoke extraction duct of sheet steel Smoke extraction duct of sheet steel The accessories that are available, as for example inspection openings, steel grilles, plenum boxes, ceiling diffusers, splitter attenuators, bends, tees and connecting

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS Dust Extractor T12600 READ ALL INSTRUCTIONS BEFORE USING Dear Customer. Thank you for choosing Ermator as your supplier. Introduction We hope that the Ermator dust extractor will

More information

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo INSTALLATION, OPERATION AND MAINTENANCE Ariterm Vedo CONTENTS General...3 Installation...4-5 Laddomat 21 Connection diagram...6 Temperature control valve...7 About burning wood...8 Operation...9-11 Service

More information

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit Packaged Gas/Electric Units Owner s Guide to Operating and Maintaining Your Gas/Electric Unit ELECTRICAL SHOCK HAZARD. FIRE OR EXPLOSION HAZARD Disconnect power at fuse box or service panel before performing

More information

Glass Chimney Hood. Installation & User Instructions Please keep for future reference

Glass Chimney Hood. Installation & User Instructions Please keep for future reference Glass Chimney Hood Installation & User Instructions Please keep for future reference 4897549 4897556 Important Please read these instructions fully before installing or using These instructions contain

More information

Instruction manual ASPIMAX 16

Instruction manual ASPIMAX 16 Manufacturer: deconta GmbH Im Geer 20, 46419 Isselburg Type-No.: 530 ( / 400) 540 ( / 230) Serial-No.: Table of contents on page 1 Basic safety advice 3 2 Technical description 4 2.1 Functionality Filter

More information

Installation & Operating Manual ZM kW Universal Oil Heater. ZMH Ltd t/a Z M Heaters T (0)

Installation & Operating Manual ZM kW Universal Oil Heater. ZMH Ltd t/a Z M Heaters  T (0) Installation & Operating Manual ZM-130 16 32kW Universal Oil Heater OVERVIEW Dfdfdfdsfd Dfdfffdfdf Dfdfdf 4 1. Overheat thermostat 2. Combustion chamber lid 3. Oil feed line 4. Activation thermostat 5.

More information

User Manual Box Exhaust Fan Series (Belt Drive)

User Manual Box Exhaust Fan Series (Belt Drive) User Manual Box Exhaust Fan Series (Belt Drive) 36" Box Exhaust Fan with Three Wing Blade Box with Aluminum Shutter 54" Box with Cone 800-779-3267 sales@schaeferfan.com www.schaeferfan.com 2013 Schaefer

More information

Operating Instructions UniTech Perfect

Operating Instructions UniTech Perfect Operating Instructions UniTech Perfect Technische Daten Rated Voltage Power Consumption Max. flow rate Max. head height Cable Protection Dimensions Weight Perfect 5000 49W 5100 l/h 1,85m Perfect 7000 78W

More information

Installation and operating instructions. DK energy storage and DK energy buffer

Installation and operating instructions. DK energy storage and DK energy buffer Installation and operating instructions DK energy storage and DK energy buffer Edition: 08-2015 1 Preliminary note With this DK energy storage / DK energy buffer you purchased a DK quality product. The

More information

3KW ELECTRIC FAN HEATER

3KW ELECTRIC FAN HEATER 3KW ELECTRIC FAN HEATER MODEL NO: DEVIL 7003 PART NO: 6935452 OPERATION & MAINTENANCE INSTRUCTIONS LS0615 INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting to use this product,

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS Dust Extractor S13 READ ALL INSTRUCTIONS BEFORE USING Introduction Dear Customer, Thank you for choosing Ermator as your supplier. We hope that the Ermator S13 dust extractor will

More information

HVG620 & HVG720 Gas Hob Manual for Installation, Use and Maintenance

HVG620 & HVG720 Gas Hob Manual for Installation, Use and Maintenance HVG620 & HVG720 Gas Hob Manual for Installation, Use and Maintenance Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer

More information

Manual. Monitoring Device BS

Manual. Monitoring Device BS Manual Monitoring Device BS-300-11 TH 42 030 8011 B/E BRANDES GmbH Subject to technical changes! Brandes GmbH - Ohmstr.1 - D 23701 Eutin - Tel.: 04521-8070 - Fax: 04521-80777 www.brandes.de - E-Mail: brandes@brandes.de

More information

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN TTV 1500 / TTV 3000 EN OPERATING MANUAL CONVEYING FAN TRT-BA-TTV1500-3000-TC2016-26-004-EN Table of contents Notes regarding the operating manual... 2 You can download the current version of the operating

More information

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS Before using the heater, read and understand all instructions and follow them carefully. The manufacturer is not responsible for damages to goods

More information

Propane Flame Projector Safety instructions and operating manual

Propane Flame Projector Safety instructions and operating manual Bigflame Propane Flame Projector Safety instructions and operating manual 1 Flame projector Bigflame Safety instructions Caution The directions in this manual must be followed strictly. It is imperative

More information

English CNA-CNB. Centrifugal fans Installation and maintenance

English CNA-CNB. Centrifugal fans Installation and maintenance 916505-0 English CNA-CNB Centrifugal fans Installation and maintenance 916505-0 GB Centrifugal fans types CNA, CNB, CNA-M and CNB-M installation and maintenance 1. Application 2. Handling 2.1 Marking 2.2

More information

Industrial ceiling fans Push down the heat from the ceiling and get significant energy savings!

Industrial ceiling fans Push down the heat from the ceiling and get significant energy savings! Industrial ceiling fans Push down the heat from the ceiling and get significant energy savings! FACTORY BUILDINGS GREENHOUSES INDOOR SPORTS WORKSHOPS DIY SUPERSTORES WAREHOUSES MARQUEES AGRICULTURE BEFORE

More information

Questions on Installation? Call: GECARES (US) or Visit our Web site at: (US) 4" DUCT CLAMPS (2) OR 4" SPRING CLAMPS (2)

Questions on Installation? Call: GECARES (US) or Visit our Web site at:  (US) 4 DUCT CLAMPS (2) OR 4 SPRING CLAMPS (2) Installation Instructions Questions on Installation? Call: 1-800-GECARES (US) or Visit our Web site at: www.geappliances.com (US) Electric Dryer 49 37 BEFORE YOU BEGIN Read these instructions completely

More information

Assembly instructions and instructions for use for electric sauna oven with evaporator. Bi-O-Mat W MADE IN GERMANY IPX en / -44.

Assembly instructions and instructions for use for electric sauna oven with evaporator. Bi-O-Mat W MADE IN GERMANY IPX en / -44. Assembly instructions and instructions for use for electric sauna oven with evaporator Bi-O-Mat W GB MADE IN GERMANY IPX4 29341224-en / -44.06 20009571 1 Important notice There is a fire risk if assembled

More information

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler Gas boiler UPON COMPLETION OF THE INSTALLATION THE INSTALLER MUST INSTRUCT THE OWNER AND OPERATOR ON THE FUNCTIONALITY AND THE PROPER OPERATION OF THE BOILER AND THE HEATING SYSTEM. INSTALLER MUST REVIEW

More information

LINDOFLAMM thermal engineering.

LINDOFLAMM thermal engineering. Catalogue LINDOFLAMM thermal engineering. Tailored solutions for every heating application. 02 LINDOFLAMM thermal engineering. Tailored solutions for every heating application. Contents. 03 All-round offering

More information

Industrial ceiling fans Push down the heat from the ceiling and get significant energy savings!

Industrial ceiling fans Push down the heat from the ceiling and get significant energy savings! Industrial ceiling fans Push down the heat from the ceiling and get significant energy savings! F AC T O R Y B UILDINGS G REENHOUSES I NDOOR S PORTS W ORKSHOPS D I Y S UPERSTORES W AREHOUSES MARQUEES AGRICULTURE

More information

ART cm Island Curved Glass

ART cm Island Curved Glass ART28101 90cm Island Curved Glass [01] x 1 [02] x 1 [03] x 1 [04] x 1 [05] x 4 [06] x 1 [07] x 1 [08] x 1 [09] x 4 [10] x 4 [11] x 1 [12] x 4 (6x70mm) [13] x 4 (6.3x17x2mm) [14] x 8 (4x12x1mm) [15] x 4

More information

Trumatic E. Trumatic E 2400 (Australia) Operating instructions Page 4 Installation instructions Page 7. To be kept in the vehicle!

Trumatic E. Trumatic E 2400 (Australia) Operating instructions Page 4 Installation instructions Page 7. To be kept in the vehicle! Trumatic E 7 7 2 9 9 4 Trumatic E 2400 (Australia) Operating instructions Page 4 Installation instructions Page 7 To be kept in the vehicle! Trumatic E 2400 (Australia) Table of contents Installation example...

More information

TTV 4500 / TTV 4500 HP / TTV 7000

TTV 4500 / TTV 4500 HP / TTV 7000 TTV 4500 / TTV 4500 HP / TTV 7000 EN OPERATING MANUAL AXIAL FAN TRT-BA-TTV4500-4500HP-7000-TC-003-EN Table of contents The current version of the operating manual can be found at: Notes regarding the operating

More information