ASHRAE WILL GIVE YOU THE WORLD. This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer Committee
|
|
- Bonnie Morgan
- 6 years ago
- Views:
Transcription
1 ASHRAE WILL GIVE YOU THE WORLD This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer Committee
2 Complete the Distinguished Lecturer Event Summary Critique CTTC needs your feedback to continue to improve the DL Program Distribute the DL Evaluation Form to all attendees Collect at the end of the meeting Compile the attendee rating on the Event Summary Critique Send the completed Event Summary Critique to your CTTC RVC and ASHRAE Headquarters Forms are available at:
3 BECOME A FUTURE LEADER INASHRAE WRITE THE NEXT CHAPTER IN YOUR CAREER ASHRAE Members who attend their monthly chapter meetings become leaders and bring information and technology back to their job. YOU ARE NEEDED FOR: Membership Promotion Research Promotion Student Activities Chapter Technology Transfer Technical Committees Find your Place in ASHRAE! Visit
4 Julian R. de Bullet ASHRAE Distinguished Lecturer debullet Consulting
5 SESSION OBJECTIVES At the end you should be able to: 1. Explain why a mechanical engineer should understand ASHRAE Standard Select the appropriate unit efficiency for a project and adjust a chiller for non-standard conditions 3. Explain when an economizer must be used 4. Describe when reheat is allowed 5. Use the fan system limitation calculation 6. State when heat recovery must be used
6 ASHRAE BECOMES CODE As a result of DOE s ruling, and by the authority provided through the Energy Conservation and Production Act, as amended, states are required to certify by Oct. 18, 2013 that they have reviewed the provisions of their commercial building code regarding energy efficiency and updated their code to meet or exceed Standard States may request extensions of this deadline from DOE if a state can demonstrate that it has made a good faith effort to comply with this code update.
7 STANDARDS AND RATING PROGRAMS Move to High Performance Buildings ASHRAE ASHRAE ASHRAE LEED 2012 ASHRAE ASHRAE LEED V Used as baseline ASHRAE LEED V ASHRAE LEED V ASHRAE LEED V ASHRAE ASHRAE LEED V ASHRAE ASHRAE ASHRAE ASHRAE LEED is a registered trademark of the U.S. Green Building Council.
8 Codes in Effect 8
9 Projected Code Adoption Dates 9
10 ASHRAE ASHRAE Addenda included, 52 affect HVAC
11 ESTIMATED SAVINGS 2007 TO
12 MAJOR CHANGES IN Scope expanded to cover plug and process loads (data centers) 2. Building envelope more stringent and high albedo roofs included 3. Interior Lighting Power Densities lowered, mandatory daylight controls and exterior lighting zones 4. Expanded equipment efficiencies, new energy recovery requirements, additional control requirements 5. Expanded energy modeling requirements (LEED ) LEED is a registered trademark of the U.S. Green Building Council. 12
13 ASHRAE 90.1 PURPOSE- CHANGES To provide minimum energy efficient requirements of buildings other than low-rise residential for: 1. Design, construction and a plan for operation & maintenance 2. Utilization of on-site renewable energy resources
14 ASHRAE 90.1 SCOPE Where required Applies to: 1. New Buildings and systems 2. New portions of buildings or systems 3. System & equipment additions in existing buildings 4. Covered portions of manufacturing facilities Does not apply to: 1. Single family, residential less than 3-story above grade or modular houses 2. Buildings that do not use electricity or fossil fuel
15 PATHS TO COMPLIANCE Mandatory These provisions must be met under all circumstances and performance can not be traded Example HVAC equipment efficiency Prescriptive These provisions are met by using the prescriptive value or using the performance method Example Air side economizer Energy Cost Budget (Performance) Allows trade-offs of prescriptive options if the total cost is equal to or less than the prescriptive option
16 ECB VS. PRM Energy Cost Budget Method Used to determine trade-off of performance of one feature against another feature Only part which is code intended Performance Rating Method Used to determine the improvement in performance of proposed versus baseline building
17 PRIMARY SECTIONS ASHRAE Regulated Sections Sect. 5.4 & 5.5 Envelope Requirements Sect. 6.4 & 6.5 HVAC Equipment Sect. 7.4 & 7.5 Service Water Heating Sect. 8.4 Power voltage drop Sect. 9.4 & 9.5 Lighting control and density Sect Electric Motors * See
18 CLIMATE ZONES Marine (C) Dry Moist (A) All of Alaska in Zone 7 except for the following Boroughs in Zone 8: Bethel Dellingham Fairbanks N. Star Nome North Slope Northwest Artic Southeast Fairbanks Wade Hampton Yukon-Koyukuk Zone 1 Includes Hawaii, Guam, Puerto Rico, and the Virgin Islands Zone 1
19 EXERCISE 2. ASHRAE 90.1 has requirements that do not regulate the energy use of which of the following? a) Lighting power density b) Plug power from computers c) Task lighting d) Minimum insulation values for roof e) Power limit for pumps on an ornamental water garden f) Maximum amount of ventilation air that can be provided g) Data centers h) Plug loads
20 SECTION 6 HVAC Section 6 Heating, Ventilation and Air Conditioning 6.1 General 6.2 Definition of Compliance Paths 6.3 Simplified Approach 6.4 Mandatory Provisions 6.5 Prescriptive Path Section 11 Energy Cost Budget Method 6.7 Submittals
21 MAJOR CHANGES TO HVAC 1. Process applications added (data centers) 2. Updated efficiency tables and added equipment types 3. Liquid to liquid heat exchangers now covered under AHRI Restrictions on pump head and pipe sizing 5. VAV requirement for CW and DX single zone units 6. Significant increase in insulation for ducts and pipe 7. Added radiant panel system requirements 8. Changes to airside economizer requirements 9. Changes to damper leakage requirements 10. Changes to reheat / recool minimum use and application 11. Requirement for dynamic ventilation control on VAV requirement from Std Limit on use of centrifugal fan open towers 13. A climatic based requirement for energy recovery 14. New requirements for garage and kitchen ventilation 15. New requirements for laboratory exhaust
22 SIMPLIFIED APPROACH 1. Building is two stories or less 2. Gross floor area is 25,000 ft 2 3. HVAC system serves one zone 4. Must have single zone VAV capability 5. Cooling system is unitary packaged or split system that meet the required efficiencies 6. Economizer must be used if required by climate zone 7. Heating must be by heat pump or furnace that meets the required efficiencies 8. Energy recovery if zone and outdoor air requirement are met 9. Must use a manual changeover thermostat 10. Heat pump lockout of supplementary heater required Star indicates an important change
23 SIMPLIFIED APPROACH (CONTINUED) 11. Reheat and simultaneous heating and cooling is prohibited even for humidity control 12. Units with motors greater than ¾ hp must have a time clock with 2-hr override, and provide setback to 55⁰F and set-up to 90⁰F 13. Pipes must be insulated per requirements 14. Duct must be sealed and insulated per requirements 15. Air balance required 16. Multiple units to a space must be interlocked 17. Exhaust in a system over 300 CFM must be equipped with gravity or motorized damper 18. Systems over 10,000 CFM must have optimum start control
24 EXERCISE 3. Which of the following is not a case covered by the scope of ASHRAE ? Choose one answer. a) The area of a building being renovated if it is more that 50% b) Refrigerant change - out with existing equipment that does not comply c) A new building that is heated but not cooled d) A high rise apartment building where the tenant furnishes their own AC unit
25 EQUIPMENT EFFICIENCIES Tables 6.8.1A Air Conditioners and Condensing Units 6.8.1B Heat Pumps 6.8.1C Water Chilling Packages 6.8.1D Packaged Terminal and Room Air Conditioners 6.8.1E Furnaces, Duct Furnaces, and Unit Heaters 6.8.1F Boilers 6.8.1G Heat Rejection Equipment 6.8.1H Heat Transfer Equipment 6.8.1I VRF Air Conditioners 6.8.1J VRF Air-to-Air & Applied Heat Pumps 6.8.1K Computer Room Units
26 EQUIPMENT EFFICIENCIES-ALL CHANGED Air-Cooled Packaged 30% Increase 17% Increase Note: Both requirements must be met
27 EQUIPMENT EFFICIENCIES-CHANGES Water-Cooled Packaged
28 IMPACT OF ASHRAE CHANGES Air Conditioner ASHRAE Air Conditioner ASHRAE
29 EQUIPMENT EFFICIENCIES Example Unit
30 CHILLER EFFICIENCIES- CHANGES COP kw / ton Conditions: 44F LWT 85F ECWT 3 GPM/ton Path A Normal duty Path B Continuous duty
31 EXAMPLE CHILLER AT NON-STANDARD Assume we have a 750 ton centrifugal chiller that meets path A requirements Full load kw/ton = 0.570, IPLV = Lvg Cond = F Lvg Evap = 42 F Lift = = F A = x (49.16) x (49.16) x (49.16) x (49.16) A = B = x = Adj Full Load kw/ton = 0.570/( x ) = NPLV = /( x ) = 0.529
32 EXERCISE 1. When evaluating if a chiller with lower efficiency can be substituted for the mandatory requirement of ASHRAE for chiller efficiency which method should be used? Choose one answer. a) The Appendix G Performance Rating Method b) The Section 11 Energy Cost Budget Method c) The prescriptive requirement from Section 6.4 d) None, since it is a mandatory requirement
33 REQUIRED CALCULATIONS Load Calculations Heating and cooling loads must be calculated per ANSI / ASHRAE / ACCA Standard Peak Heating and Cooling Calculations in Buildings Except Low-Rise Residential Pump Head Pump head must be calculated by the pressure drop in the critical circuit at design
34 6.4 MANDATORY REQUIREMENTS Ventilation Controls Stair shafts and elevators must have motorized shut-off dampers ) Outdoor air and exhaust must have automatic dampers with ability to shutoff during warm-up, cool-down and unoccupied times Gravity dampers allowed For exhaust and relief if building is 3 story For Intakes in Zones 1,2,3 System is less than 300 CFM
35 6.4 MANDATORY REQUIREMENTS Ventilation Controls 3) Damper leak rate: Ventilation Exhaust / Relief Gravity Motorized Gravity Motorized Zone 4,5b,5c < 3 Story Not allowed 10% 20% 10% 3 Story Not allowed 10% Not Allowed 10% Zone 5a,6,7,8 < 3 Story Not allowed 4% 20% 4% 3 Story Not allowed 4% Not Allowed 4%
36 6.4 MANDATORY REQUIREMENTS Ventilation Controls Ventilation fans greater than ¾ hp must have automatic shutdown capability when not required Enclosed parking garages shall be able to modulate to 50% or less of design airflow if contaminate levels are maintained
37 6.4 MANDATORY REQUIREMENTS :Heat Pump Auxiliary Heat Control Supplemental heater must have controls that prevent operation when the heat pump is capable of meeting the load during operation and recoveryheater operation is permitted during defrost :Humidification and Dehumidification System must be able to prevent humidification from working when dehumidification is active :Freeze Protection and Snow Melting Systems Must be deactivated above 40⁰F
38 6.4 MANDATORY REQUIREMENTS :Ventilation Controls for High Occupancy High occupancy is > 40 people/1000 ft 2 For spaces > than 500 ft 2 require DCV if system has: Airside economizer Automatic modulating control of outdoor air damper Airflow > 3000 CFM Unless: System exhaust energy recovery ( ) System does not have a DDC system System outdoor airflow is 1,200 CFM
39 SINGLE ZONE VAV CONTROLS CW AHU or fan coil with motor >5 hp must have either 2 speed motor or VFD to reduce airflow at 50% demand or less to either a) ½ of full speed b) Airflow required for ventilation per Std As of 1/1/2012 DX units 110,000 Btuh or more must have either 2 speed motor or VFD to reduce airflow at 50% demand or less to 1) ⅔ of full speed 2) Airflow required for ventilation per Std 62.1
40 DUCT SEALING 1. All duct above 2 wg. and upstream of VAV boxes must be sealed to class A 2. Pressure testing of minimum of 25% of duct area required on duct systems over 3 wg.
41 EXERCISE 4 1. Select 3 mandatory requirements of ASHRAE related to HVAC units? Pick at least three answers. a) HVAC equipment part load efficiency b) 20 degree differential in WSHP loop boiler off to cooling tower on temperature c) Pumps with over 50 HP must have a VFD d) Reheat limited to less than 0.4 CFM / ft 2 e) Motorized damper leakage at no more than 10 CFM / ft 2 f) Optimum start control for systems over 10,000 CFM g) Dead band of at least 5 F between heating and cooling setpoint
42 6.5.1.ECONOMIZER REQUIREMENTS Comfort Cooling (air or water) All zones except 1a and 1b 54,000 Btu/h Computer Rooms Zones 1a, 1b, 2a, 3a, 4a - Not required Zones 2b, 5a, 6a, 7, 8 135,000 Btu/h Zones 3b, 3c, 4b, 5b, 5c 6b 65,000 Btu/h Exceptions: Non-particulate air treatment required by Std 62.1 Hospitals with >75% space requiring humidification above 35 F dewpoint Condenser heat recovery is used Residential spaces If internal sensible cooling at design is less that transmission at 60F System operation less that 20 hr / week Supermarkets when it will impact case If unit efficiency exceeds 42% better in 4a and 49% better in zone 5a Computer rooms in some conditions
43 PRESCRIPTIVE REQUIREMENTS Economizers Air Economizer Modulate outdoor air and return air to provide 100% of supply air quantity must provide relief Must be integrated with cooling and can not be controlled only by mixed air temperature Relief that prevents recirculation must be provided High limit cut-off Control Zone 4a Zone 5a Fixed Dry Bulb Not Allowed T OA > 70 Differential Dry Bulb Not Allowed T OA > T RA Fixed Enthalpy h OA > 28 Btu/lb Electronic Enthalpy Differential Enthalpy Dew-point and dry-bulb (T OA,RH OA )> A h OA > h RA DP OA >55F or T OA > 75F
44 PRESCRIPTIVE REQUIREMENTS Economizers Water Economizer Provide 100% of capacity by indirect evaporative cooling at 50⁰F DB and 45⁰F WB Pressure drop can not exceed 15 ft on primary or use a secondary loop Must use integrated economizer Except: Some computer room applications System where dehumidification requirements can not be met at 50⁰F DB and 40⁰F WB : All Economizer Economizer operation can not increase the need for heating energy at normal conditions
45 EXERCISE 5 5. A chiller using glycol solution with a freezing point less than 27⁰ F should use which efficiency rating condition? Select one answer a) Full load kw / ton b) Full load COP c) Part load IPLV d) None These are outside the range e) EER rating f) IEER rating
46 6.5.2 PRESCRIPTIVE REQUIREMENTS Simultaneous Heating and Cooling Limits Zone controls must prevent: Reheating Re-cooling Mixing of air that has been mechanically heated or cooled by mechanical cooling or economizer Other simultaneous operation of heating and cooling
47 6.5.2 PRESCRIPTIVE REQUIREMENTS Simultaneous Heating and Cooling Limits Condition 1 Exceptions where reheat is allowed if the air reheated is less than the larger of the following: 1. Air is no less than the required zone ventilation air per Standard Air is < 30% of peak design airflow 3. If allowed by AHJ when shown that it reduces total energy 4. Zones requiring pressure differential or code requirement AHJ: Authority having jurisdiction
48 6.5 PRESCRIPTIVE REQUIREMENTS Simultaneous Heating and Cooling Limits Condition 2 Exceptions where reheat is allowed if the zone meets all the following: 1. Airflow rate in the dead band between heating and cooling is not larger than: 1. 20% of the zone peak airflow 2. Required zone ventilation air per Standard If allowed by AHJ when shown that it reduces total energy 2. Reheat, recooled or mixed air is less than 50% of peak 3. Airflow between dead band and full heating and full cooling can be modulated
49 6.5 PRESCRIPTIVE REQUIREMENTS Simultaneous Heating and Cooling Limits Condition 3 Exceptions where reheat is allowed if: 1. Laboratory exhaust that meets Section Condition 4 Exceptions where reheat is allowed if: 1. 75% of the reheat energy is from site recovered energy or site-solar assisted energy
50 EXERCISE 6. New energy for reheat is allowed in which 3 of the following situations? Select three answers. a) The airflow has been reduced to the minimum ventilation air allowed by ASHRAE 62.1 b) Minimum air volume is < than 0.4 CFM/FT 2 c) Reheat is only allowed if no new energy is used d) Reheat is never allowed except in process applications e) Air being reheated is < 30% of peak design airflow
51 6.5 PRESCRIPTIVE REQUIREMENTS Air System Design and Control Systems over 5 hp total system nameplate must meet the fan hp limitation based on name plate hp Fan Power limitation Supply fans, return fans, relief fans, exhaust fans and fan-powered terminal units must meet option 1 or option 2 Exceptions: Hospital and labs where pressure differential must be maintained can use VAV fan power limit Individual exhaust fans with motor name plate of 1 hp or less Motor nameplate can be no larger than the next available motor size Exceptions: If bhp is < 6 motor can be within 50% of bhp If bhp is 6 motor can be within 30% of bhp
52 FAN POWER EXAMPLE Option 1 VAV system supplying 25,000 CFM hp limit = CFMs x = 25,000 x = 37.5 hp Maximum is then 37.5 Nameplate hp AHU systems with 30 hp supply and 7.5 hp exhaust nameplate motors would be acceptable Option 2 Same systems full ducted and MERV 13 filters hp limit = CFM s x A A = Pd x CFM / 4131 A duct = 0.5 x 22,000/4131 = 2.66 A MERV 13 = 0.9 x 25,000/4131 = 5.44 hp limit = 25,000 x = 40.6 bhp Maximum is then 40.6 bhp 52
53 VAV FAN POWER LIMITS (Includes series fan power boxes) All motors 10 hp and larger must: 1. Be driven by a mechanical or electrical variable speed drive 2. Or use a vane-axial or variable pitch fan 3. Or have controls that will reduce motor demand to 30% of design watts at 50% flow Static pressure sensor must be placed so that the controller setpoint is no more than 1/3 of total design static On DDC systems static setpoint must be reset by the zone with the largest demand 53
54 SUPPLY AIR TEMPERATURE RESET Multiple zone systems must ( ): Provide reset control of supply air in response to load or outdoor air temperature Must be capable of resetting 25% of the difference between supply air and room setpoint Reset based on humidity is allowed Equipment rooms (data centers) must be able to fully reset Except: Zones 1a, 2a and 3a Systems that prevent reheating, re-cooling or mixing Systems with 75% reheat energy from site recovered or site solar 54
55 EXERCISE 7. ASHRAE 90.1 has a prescriptive requirement which limits the fan power energy. Which of these statements is true? Select one answer a) The calculation only applies to the power at part load conditions of VAV units using a variable frequency drive b) A correction factor is applied when filters with a MERV rating greater than MERV 8 are used c) The calculation of fan power applies to supply, return, and exhaust fans but not the fans in VAV fan powered terminals. d) The power calculation must be based on the nameplate rating of the motor only
56 6.5.4 PRESCRIPTIVE REQUIREMENTS Hydronic System Control Systems with pumps 10 hp and larger and control valves must be capable of reduction to 50% design flow Pumps over 5 hp must have the ability to reduce to 30% power at 50% flow Controls shall function to maintain minimal pressure differential and drive the valve with the greatest demand full open Differential pressure should be no more that required for 110% of heat exchanger flow Exceptions: Flow less than manufactures minimum where pump hp is 75 hp or less System has no more than 3 control valves
57 6.5 PRESCRIPTIVE REQUIREMENTS Hydronic System Control Pumps on systems with more than one chiller must have isolation of the used chiller ( ) Chilled and hot water in systems > 30,000 Btu/h must reset chilled and hot water temperature based return water temperature or outdoor temperature ( ) Except: When control reset will cause improper operation of heating, cooling, humidifying or dehumidification Hydronic systems using variable flow pumping Hydronic loops must use two-position isolation valves to stop water flow when the compressor is off applies to WSHP and unitary water cooled units
58 6.5.6 PRESCRIPTIVE REQUIREMENTS Energy Recovery Exhaust air energy recovery is required if: Exhaust Air Heat Recovery
59 EXERCISE 8. Heat recovery is required by ASHRAE under certain conditions. Which requirements are true? Select one answer. a) In zone 5a the airflow is 5500 CFM and 30% is outside air b) The energy effectiveness is less than 50% c) An economizer is not required if an ERV with a thermal effectiveness of 50% or better is used d) Energy recovery is required if 75% of the lab hood are not controlled by a demand control ventilation or schedule
60 6.5.9 PRESCRIPTIVE REQUIREMENTS Hot Gas Bypass Limitation Cooling systems can not use hot gas bypass or evaporator pressure control unless multiple steps of capacity are provided and maximum hot gas is limited to: 240,000 Btu/h 50% maximum > 240,000 Btu/h 25% maximum Exception: Unitary systems less than 90,000 Btu/h This includes screw and centrifugal machines and is based on the system size IE: 100 ton machine can not bypass more than 25 tons
61 Service Water Booster Systems One or more pressure sensors shall be used to vary the pump speed and/or start and stop the pumps. No device shall be installed for the purpose of reducing the pressure of all of the water supplied by any booster system pump or booster system, except for safety devices. No booster system pumps shall operate when there is no service water flow Conclusion Every booster pump system will be variable flow 61
62 ASHRAE 90.1 NORMATIVE APPENDIX G Performance Rating Method Demonstrate a percentage improvement above the baseline building Note: Based on energy costs Must meet 90.1 mandatory requirements Must include all project energy costs Baseline building must comply with Appendix G requirements Process energy requirements Appendix G is for modeling improved performance not tradeoff calculations
63 THANK YOU! 63
64
HVAC Mandatory Provisions Part II, Page 1
HVAC Mandatory Provisions Part II, Page 1 Mandatory Equipment Efficiency Worksheet (6.4.1.1) System Equipment Type Size Category (Tables 6.8.1A through K) Sub-Category or Rating Condition Units of Efficiency
More information2009 IECC Commercial Mechanical Requirements
BUILDING ENERGY CODES UNIVERSITY 2009 IECC Commercial Mechanical Requirements Ken Baker PNNL-SA-66171 Learning(Objec-ves(( ( 1. Find(minimum(equipment(efficiency(requirements( and(recite(at(least(3(common(terms(for(measuring(
More informationINTRODUCTION TO: ASHRAE STANDARD 90.1, HVAC System Requirements for Reducing Energy Consumption in Commercial Buildings
INTRODUCTION TO: ASHRAE STANDARD 90.1, 2013 HVAC System Requirements for Reducing Energy Consumption in Commercial Buildings Rocky Mountain ASHRAE Technical Conference, April 29, 2016 SEAN BEILMAN, P.E.,
More informationASHRAE/IESNA Standard
ASHRAE/IESNA Standard 90.1-1999 An inside look at the requirements of Standard 90.1-1999 Energy Standard for Building Except Low-Rise Residential Building Mick Schwedler, PE Sr. Principal Applications
More informationCOMcheck Software Version Review Mechanical Compliance Certificate
COMcheck Software Version 4.0.7.2 Review Mechanical Compliance Certificate Section 1: Project Information Energy Code: 2014 Oregon Energy Efficiency Specialty Code Project Title: Benton County Health Project
More informationNET ENERGY WATER LOOPS A clear path to net zero energy buildings
Presents NET ENERGY WATER LOOPS A clear path to net zero energy buildings Alan Niles WaterFurnace International This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer
More informationAugust 15, 2013 Page 1 of 19
Section C401 Application Compliance with C402, C403, C404 and C405 AND (either C406.2, C406.3 or C406.4) Compliance with C402, C403, C404 or C405 Section C402 Building Envelope (Climate Zone 5A) Space-Conditioning
More informationChiller Plant Design. Julian R. de Bullet President debullet Consulting
Chiller Plant Design Julian R. de Bullet President debullet Consulting 703-483-0179 julian@debullet.com This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer ASHRAE
More information1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.
2018 NC Energy Conservation Code Commercial Mechanical Module 7 CHAPTER 5 [CE] WORKSHEET 1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the
More informationSESSION Michigan Energy Code (MEC) Update (3 Technical) Per SMACNA Standard (TAB, Duct Design) and ASHRAE ( ) ASHRAE Detroit Members:
SESSION 1-2015 Michigan Energy Code (MEC) Update (3 Technical) Per SMACNA Standard (TAB, Duct Design) and ASHRAE (90.1.2013) ASHRAE Detroit Members: AM Session is eligible for (X) Professional Development
More information2009 Washington State Non-Residential Energy Code Scott Rushing, PE, LEED AP - Rushing Company Lisa Rosenow, CSBA, LEED AP NEEC
2009 Washington State Non-Residential Energy Code Scott Rushing, PE, LEED AP - Rushing Company Lisa Rosenow, CSBA, LEED AP NEEC Mechanical Systems Agenda Changes in NREC Chapter 11 Changes in NREC Chapter
More informationASHRAE Standard 90.1 Energy Requirements Wrap-Around Heat Pipes
ASHRAE Standard 90.1 Energy Requirements Wrap-Around Heat Pipes In Humid Climates BY DAVID A. JOHN, P.E., MEMBER ASHRAE; DREW ELSBERRY, MEMBER ASHRAE Designing g a building s HVAC system requires designers
More informationCOMcheck Software Version Mechanical Compliance Certificate
COMcheck Software Version 3.8.2 Mechanical Compliance Certificate 90.1 (2007) Standard Section 1: Project Information Project Type: New Construction Project Title : Rudy's Star Motors Construction Site:
More informationCOMcheck Software Version Mechanical Compliance Certificate
COMcheck Software Version 4.0.8.1 Mechanical Compliance Certificate Project Information Energy Code: Location: Climate Zone: Project Type: 90.1 (2013) Standard Buda, Texas 2a New Construction Construction
More informationCOMcheck Software Version Mechanical Compliance Certificate
COMcheck Software Version 4.0.6.2 Mechanical Compliance Certificate Project Information Energy Code: Location: Climate Zone: Project Type: 90.1 (2007) Standard HALCYON Bldg. 400 Alpharetta, Georgia 3a
More information1 - This title will copy onto other forms Date
2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Mechanical Summary MECH-SUM Project Title: 1 - This title will copy onto other forms Date 1/1/2015
More informationCOMcheck Software Version Mechanical Compliance Certificate
COMcheck Software Version 4.0.3.0 Mechanical Compliance Certificate Section 1: Project Information Energy Code: 2014 Oregon Energy Efficiency Specialty Code Project Title: AHSC (Asian Heal Service Center
More informationApplication of the 2012 North Carolina Energy Conservation Code
Application of the 2012 North Carolina Energy Conservation Code Commercial Mechanical Presented By: NC Code Officials Qualification Board Office of State Fire Marshal NC Department of Insurance 2012 Modules
More information2006 Washington State Nonresidential Energy Code Compliance Form Washington State Nonresidential Energy Code Compliance Forms Revised July 2007
Mechanical Summary 2006 Washington State nresidential Energy Code Compliance Form MECH-SUM 2006 Washington State nresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address
More informationMechanical Compliance Certificate
COMcheck Software Version 4.0.7.0 Mechanical Compliance Certificate Project Information Energy Code: Location: Climate Zone: Project Type: 90.1 (2013) Standard Austin, Texas 2a (weather data: TBD) New
More informationCOMcheck Software Version Mechanical Compliance Certificate
COMcheck Software Version 4.0.4. Mechanical Compliance Certificate Project Information Energy Code: Location: Climate Zone: Project Type: 205 IECC Dallas, Texas 3a New Construction Construction Site: 56
More informationTechnical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler
Technical Development Program COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Introduction System
More informationERRATA SHEET FOR ANSI/ASHRAE/IES STANDARD (I-P Edition) Energy Standard for Buildings Except Low-Rise Residential Buildings.
ERRATA SHEET FOR ANSI/ASHRAE/IES STANDARD 90.1-2013 (I-P Edition) Energy Standard for Buildings Except Low-Rise Residential Buildings July 7, 2017 The corrections listed in this errata sheet apply to ANSI/ASHRAE/IES
More informationONTARIO BUILDING CODE AND SUPPLEMENTARY STANDARD SB-10 PROJECT INFORMATION. Mechanical Designer Information*
ONTARIO BUILDING CODE AND SUPPLEMENTARY STANDARD SB-10 PROJECT INFORMATION Project: Building Permit Application No.: DETAILED FORMS Location: Date: Architectural Designer Information* Mechanical Designer
More informationSECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS
SECTION 23 09 93 SEQUENCE OF OPERATIONS FOR HVAC CONTROLS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes control sequences for HVAC systems, subsystems, and equipment. B. See Division 23 Section
More informationCOMcheck Software Version Interior Lighting Compliance Certificate
Section 1: Project Information Energy Code: 2009 IECC Project Title: Berry Farms Animal Hospital Project Type: New Construction COMcheck Software Version 4.0.3.0 Interior Lighting Compliance Certificate
More informationC.E.P., C.E.M, C.I.P.E.
Subject What everyone needs to know about ASHRAE 90.1 J. Christopher Larry, P.E., C.E.P., C.E.M, C.I.P.E. Thursday, Joint ASHRAE AEE Meeting Cleveland, Ohio Introduction J. Christopher Larry P.E., C.E.P.,
More information2011 Manitoba Energy Code for Buildings (MECB) PART 5, Heating, Ventilating and Air-conditioning Systems
2011 Manitoba Energy Code for Buildings (MECB) PART 5, Heating, Ventilating and Air-conditioning Systems Dieter Bartel, Manitoba Hydro September 17 th, 2014 Outline Scope and compliance Prescriptive path
More informationAIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University
AIR-CONDITIONING SYSTEMS AND APPLICATIONS Abdullah Nuhait Ph D. King Saud University AIR-CONDITIONING SYSTEMS Earliest air conditioning system used only for heating (winter) Provided heated air for comfort
More informationHVAC Controls Upgrades: Requirement Details ( )
REQUIRED CONTROLS/FEATURES To qualify the upgrade must add or substantially modify 3 or more sequences/system capabilities. Also, all sequences and items listed under the required section are needed in
More informationThe Creative and Performing Arts High School (CAPA) Pittsburgh, PA 11/11/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma
Objectives and Requirements For the Creative and Performing Arts High School (CAPA), the main objective of the mechanical design is to provide an energy efficient system that is easily maintainable and
More informationHVAC Controls Upgrades: Requirement Details ( )
REQUIRED CONTROLS/FEATURES HVAC non CENTRAL PLANT 1) Zone Level Scheduling & Override for all air handlers (supply and exhaust) to match occupied hours by zone DDC or occupancy sensors (OS) allowed. (403.2.4.3,
More informationSECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS
PART 1 - GENERAL SECTION 23 09 93 SEQUENCE OF OPERATIONS FOR HVAC CONTROLS 1.1 SUMMARY A. This Section includes control sequences for HVAC systems, subsystems, and other equipment. B. See Division 23 Section
More informationDesigning Energy Efficient Outdoor Air Systems
Designing Energy Efficient Outdoor Air Systems Joseph Thorndal Applied Products Sales Manager Greenheck, Schofield, Wisconsin 1 Joseph Thorndal BS Industrial Engineering North Dakota State University Work
More informationDehumidifying with Dedicated Outdoor Air
Dehumidifying with Dedicated Outdoor Air System Configurations Figure 71. Configurations for dedicated outdoor-air systems A dedicated outdoor-air handler separately filters, cools, dehumidifies, heats,
More informationHigh Performance Building Guide 1
Description This Guide is intended to be used for projects with a Vermont Certified: High Performance energy efficiency goal. This High Performance goal is a whole-building efficiency approach rather than
More informationAgenda and Objectives
Agenda and Objectives Trane Engineers Newsletter Live Series Rooftop variable-air-volume (VAV) systems are used to provide comfort in a wide range of building types and climates. This ENL discusses HVAC
More informationIntroduction to HVAC. American Standard Inc Air Conditioning Clinic TRG-TRC018-EN
Introduction to HVAC Agenda Psychrometrics Human Comfort Heat Transfer Refrigeration Cycle HVAC Terminology HVAC Systems Introduction to HVAC Psychrometrics 2000 TRG-TRC002-EN Properties of Air Dry-bulb
More informationINTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012
HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O INTRODUCTION HVAC systems or Heating, Ventilating and Air-Conditioning systems control the environment for people and equipment in our facilities.
More informationAndrea Borowski The Pennsylvania State University University Park, PA November 11, 2002 Consultant: Dr. Bahnfleth Technical Assignment M-3
Existing System Evaluation Executive Summary The MBNA Career Services Center is a 44,000 square foot, 4-story office type building at Penn State University, University Park Campus. The building is located
More informationTechnical Assignment 3. Mechanical Systems Existing Conditions Evaluation
Technical Assignment 3 Mechanical Systems Existing Conditions Evaluation The Milton Hershey School New Supply Center Prepared for: William P. Bahnfleth, Ph.D., P.E., Professor Department of Architectural
More informationUNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1
GENERAL: This section provides general standards for overall sizing and design of Heating, Ventilating, and Air Conditioning (HVAC) systems. Other sections contain specific standards for each system per
More informationCOMMERCIAL ENERGY EFFICIENCY
CHAPTER 5 COMMERCIAL ENERGY EFFICIENCY SECTION 501 GENERAL 501.1 Scope. The requirements contained in this chapter are applicable to commercial buildings, or portions of commercial buildings and to multiple-family
More informationPRE-PRINT APPENDIX E GREEN MECHANICAL CODE SUPPLEMENT
GREEN MECHANICAL CODE SUPPLEMENT E 101.0 General. E 101.1 Scope Applicability. The purpose of this appendix is to provide a comprehensive set of technically sound provisions that encourage sustainable
More informationHumidity Control & Psychrometrics
Humidity Control & Psychrometrics Iowa Chapter of ASHRAE March 22, 2017 R. Mark Nunnelly, P.E., CxA, LEED AP Nunnelly & Associates, Inc. Commissioning & Humidity Control Consulting Birmingham, AL mnunnelly@nunnellyengineering.com
More informationEnergy Recovery with Cooling and Heating Model ERCH
Energy Recovery with Cooling and Heating Model ERCH 100% Outdoor Air System Dedicated Outdoor Air System 1,000-10,000 cfm 1.75 in. wg External Static Pressure Indirect Gas, Hot Water, Electric Heating,
More informationEnergy-Efficient Makeup Air Units BY HUGH CROWTHER, P.ENG., MEMBER ASHRAE
This article was published in ASHRAE Journal, March 20145 Copyright 2015 ASHRAE. Posted at www.ashrae.org. This article may not be copied and/or distributed electronically or in paper form without permission
More informationPINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION
ENERGY EFFICIENT DEHUMIDIFICATION PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM Provides a very high degree of latent cooling using only a minimal amount of conventional cooling input Substantial energy
More informationREAD ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter Adopt Entire Chapter as amended (amended sections listed below)
CALIFORNIA MECHANICAL CODE MATRIX ADOPTION TABLE APPENDIX E SUSTAINABLE PRACTICES (Matrix Adoption Tables are non-regulatory, intended only as an aid to the user. See Chapter 1 for state agency authority
More informationHVAC Trajectories toward Zero
HVAC Trajectories toward Zero Jon McHugh, McHugh Energy at WCEC Affiliate Forum Western Cooling Efficiency Center Davis, CA May 7, 2013 jon@mchughenergy.com McHugh Energy Consultants CPUC Big Bold EE Strategies
More informationRooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating
Rooftop Ventilator with Packaged Cooling & Heating Models RV and RVE Institutional Commercial Industrial 800-1,500 cfm.0 in. wg External Static Pressure Indirect Gas, Hot Water, Electric Heating Packaged
More informationCOMcheck Software Version
COMcheck Software Version 4.0.4. Mechanical Compliance Certificate Project Information Energy Code: Location: Climate Zone: Project Type: 205 IECC Salt Lake City,Utah 5b New Construction Construction Site:
More informationEADQUARTERS. Technical Report One. Stephanie Kunkel Mechanical Option
EADQUARTERS 707 N. Calvert St. Technical Report One ASHRAE Standard 62.1 Ventilation ASHRAE Standard 90.1 Energy Design Stephanie Kunkel www.engr.psu.edu/ae/thesis/portfolios/2011/slk5061 Mechanical Option
More informationCHAPTER 4. HVAC DELIVERY SYSTEMS
CHAPTER 4. HVAC DELIVERY SYSTEMS 4.1 Introduction 4.2 Centralized System versus Individual System 4.3 Heat Transfer Fluids 4.4 CAV versus VAV Systems 4.5 Common Systems for Heating and Cooling 4.6 Economizer
More informationSession: HVAC 101 HVAC 101. Steve Sain Sain Engineering Associates, Inc. August 9, Rhode Island Convention Center Providence, Rhode Island
Session: HVAC 101 HVAC 101 Steve Sain Sain Engineering Associates, Inc. August 9, 2016 Rhode Island Convention Center Providence, Rhode Island Why? 2 Acknowledgements 3 Disclaimer I m gonna shoot down
More informationHVAC 101. H V A C S y s t e m s
H V A C 1 0 1 S y s t e m s Introduction & Overview Should you care? Mechanical System Types Components & operation Popular Application Key Issues and Design Considerations System Comparisons First Cost
More informationGil Rossmiller. In the construction industry for over 30 years. ICC IRC Plumbing & Mechanical Code Development Committee
Gil Rossmiller In the construction industry for over 30 years ICC IRC Plumbing & Mechanical Code Development Committee ICC- IECC Commercial Energy Code Development Committee Building Official Parker, Colorado
More informationJob Name Control Systems Description Date
Job Name Control Systems Description Date Project Overview The project is a describe the building and its major HVAC systems (e.g. three-story office building, served by a rooftop unit VAV system ). In
More informationAPPLICATION GUIDE BEAMS
BEAMS There is an increasing need for energy efficient air conditioning systems as energy codes become more stringent. Chilled beam systems are one such alternate to traditional all air conditioning systems.
More informationCOMcheck Software Version Mechanical Compliance Certificate
COMcheck Software Version 3.9.4 Mechanical Compliance Certificate 01 IECC Section 1: Information Type: Addition Title : Construction Site: Owner/Agent: Designer/Contractor: 3030 North Industrial Way Castle
More informationSummary Comparison of Simulation Program Features
Summary Comparison of Simulation Program Features FEATURE DOE2.2 equest TRACE 700 HAP Public/Proprietary Public Domain Proprietary Proprietary Proprietary Simulation Method 8760 hours 8760 hours 8760 hours
More informationUpdate Dedicated Heat Recovery Chiller Technology. Don Frye. Gulf South
3/5/2018 1 Update Dedicated Heat Recovery Chiller Technology Don Frye Gulf South Good design is an intentional act Begin with the end in mind Basic Bldg Tenants IAQ (low VOC & CO 2 ) Controlled Temp &
More informationTechnical Report #3 Mechanical Systems Existing Conditions Evaluation
Mechanical Option Technical Report #3 Technical Report #3 Mechanical Systems Existing Conditions Evaluation Instructor: Dr. Bahnfleth 11.15.04 Building Sponsor: CCG Facilities Integration Table of Contents
More informationterminal units only provide sensible cooling, a separate dehumidification system is usually needed.
providing insights for today s hvac system designer Engineers Newsletter volume 44 3 Dual-Temperature Chiller Plants This Engineers Newsletter describes several dual-temperature configurations that can
More informationDEHUMIDIFICATION: Ice Arena Application & Product Guide. Design, construct and operate to control indoor humidity in ice rinks
DEHUMIDIFICATION: Ice Arena Application & Product Guide Design, construct and operate to control indoor humidity in ice rinks Munters is the world leader in dehumidification Munters is the largest manufacturer
More informationEnergy-Efficiency Measures List
Guidelines for Public Agencies Energy-Efficiency Measures List 1.0 Envelope 1.1 Reduce Heat Losses-Ceiling/roof 1.11 Additional Ceiling/Roof Insulation 1.12 Exhaust Attics 1.13 Use Light-Colored Roof Surfaces
More informationA. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.
SECTION 23 09 93 - SEQUENCE OF OPERATIONS FOR HVAC CONTROLS PART 1 - GENERAL 1 WORK INCLUDES A. Base Bid: Heating Contractor provide: Control sequences for HVAC systems, subsystems, and equipment. B. Alternate
More informationAHRI Certification Program Scopes - COOLING
Air-to-Air Energy Recovery Ventilators (AHRI Std. 1060) Automatic Commercial Ice-Cube Machines and Ice Storage Bins (AHRI Stds. 810 & 820) Central Station Air-Handling Units (AHRI Std. 430) Commercial
More informationPresented By: John Dolan, P.E.
Variable Speed Compressor Technologies Presented By: John Dolan, P.E. President - Thermosystems, Inc. BS in Mechanical Engineering from UIUC 29 years HVAC Equipment Application Experience jdolan@thermohvac.com
More informationEnergy Recovery with Cooling and Heating
Energy Recovery with Cooling and Heating VersiVent - Model VER Commercial Institutional 2,000-10,000 cfm 3.0 in. wg external static pressure Configurable September 2008 Page The VersiVent Header Model
More informationCOMcheck Software Version Interior Lighting Compliance Certificate
Section 1: Project Information Energy Code: 2009 IECC Project Type: New Construction COMcheck Software Version 4.0.2.8 Interior Lighting Compliance Certificate Construction Site: Owner/Agent: Designer/Contractor:
More informationAHRI 920 Performance Rating and Comparisons of DX-DOAS Unit Efficiency
Application Note 24 AHRI 920 Performance Rating and Comparisons I NTRODUCTION In 2015, the Air-Conditioning, Heating, and Refrigeration Institute (AHRI) introduced a performance rating for dedicated outside
More informationCOMMERCIAL HVAC PACKAGED EQUIPMENT. Split Systems
COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems Technical Development Programs (TDP) are modules of technical training on HVAC theory, system design, equipment selection and application topics. They are
More informationInspection Phase Three. Mechanical, Electrical & Plumbing Section 503
Inspection Phase Three Mechanical, Electrical & Plumbing Section 503 COMCheck Mechanical Field Inspection Checklist Mechanical Mechanical, Electrical & Plumbing Equipment Efficiencies But a lot ore too
More informationDesign Considerations For Dedicated OA Systems BY HUGH CROWTHER, P.ENG, MEMBER ASHRAE; YI TENG MA, ASSOCIATE MEMBER ASHRAE
ASHRAE www.ashrae.org. Used with permission from ASHRAE Journal. This article may not be copied nor distributed in either paper or digital form without ASHRAE s permission. For more information about ASHRAE,
More informationASHRAE Region VI CRC Track III: Session 3 Ventilation Energy Recovery. Steven T. Taylor, PE Principal Taylor Engineering
ASHRAE Region VI CRC Track III: Session 3 Ventilation Energy Recovery Steven T. Taylor, PE Principal Taylor Engineering This program is registered with the AIA/CES for continuing professional education.
More informationSeries PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:
RZ PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS Features: Air-cooled condenser, water-cooled condenser, or evaporative-cooled condenser packaged rooftop units from 55-240 tons Water-source
More informationMechanical Technical Report 3. Mechanical Systems Existing Conditions Evaluation
Mechanical Technical Report 3 Lutheran Theological Seminary at Philadelphia The New Learning Center Prepared For: William P. Bahnfleth, Ph.D., P.E. Department of Architectural Engineering Pennsylvania
More informationFAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney
FAST AND ROBUST BUILDING SIMULATION SOFTWARE Chilled Beam Performance: 1 Shelly Street, Sydney 3D Model Creation 1 Shelley Street, Sydney 3D Model Creation 1 Shelley Street, Sydney Daylight Analysis 1
More informationASHRAE WILL GIVE YOU THE WORLD. This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer Committee
ASHRAE WILL GIVE YOU THE WORLD This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer Committee Complete the Distinguished Lecturer Event Summary Critique CTTC
More informationBOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:
4510 Helgesen Drive, Madison, WI, 53718 608.221.4499, 800.627.4499, Fax: 608.221.2824 support@renewaire.com www.renewaire.com RD2XRT INSTALLATION AND OPERATION MANUAL BOOK 1 OVERVIEW ABOUT BOOK 1: This
More informationCOMMERCIAL HVAC PACKAGED EQUIPMENT. Rooftop Units Level 1: Constant Volume
COMMERCIAL HVAC PACKAGED EQUIPMENT Rooftop Units Level 1: Constant Volume Technical Development Programs (TDP) are modules of technical training on HVAC theory, system design, equipment selection and application
More informationb.) Technical Information:
Section VI- Strategies a.) Summary: It is important for new construction designers to consider the heating, ventilation, and air conditioning needs within a building. There are many different systems,
More informationLGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.
Service Literature The LGH/LCH high and standard efficiency 5, 0, 5 and 50 ton (, 0.7, 58. and 75.9 kw) units, are configure to order units (CTO) with a wide selection of factory installed options. The
More informationHeat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:
Heat Pumps SA SERIES SA Series Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features: Vertical self-contained units with capacities from 23 70 tons Direct drive backward curved plenum
More informationPACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.
RN/RQ Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS RQ Series Features: Air-cooled or water-cooled condenser, with unit capacities
More informationH3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog
H3/V3 Series Horizontal and Vertical Indoor Air Handling Units Engineering Catalog Table of Contents AAON H3/V3 Series Features and Options Introduction... 6 H3/V3 Base Model Description... 7 Unit Size...
More information4. OVERVIEW OF MECHANICAL SYSTEM
4. OVERVIEW OF MECHANICAL SYSTEM The 87,000 SF SLCC is served by six (6) Trane M-Series Climate Changer Air Handing Units (AHUs). Each unit serves a distinct zone within the facility that is unique in
More informationCOMMERCIAL HVAC EQUIPMENT Indoor Self-Contained Units
COMMERCIAL HVAC EQUIPMENT Indoor Self-Contained Units Technical Development Program Technical Development Programs (TDP) are modules of technical training on HVAC theory, system design, equipment selection
More informationState of the art building simulation software... Frenger Radiant chilled beam performance at 1 Shelly St - Sydney
Frenger Radiant chilled beam performance at 3D Model Creation Daylight Analysis Comparison of the performance of various HVAC systems at 1 Shelly St, Sydney VAV fancoil Active chilled beam Passive chilled
More informationTerminal. Las Vegas, NV. Technical
McCarran International port Terminal 3 Technical Assignment 3 Mechanical System Existing Conditions Evaluation December 3, 2007 Prepared By: Faculty Advisor: Dr. William Bahnfleth, Ph.D., P..E. Table of
More informationENGINEERING. Edition No. 13 October 2002
Edition No. 13 October 2002 ENGINEERING S Y S T E M S O L U T I O N S W e at McQuay are very proud of our tradition of producing industry leading water source heat pumps. Our heritage stretches back more
More informationMECHANICAL INFRASTRUCTURE ASSESSMENT FOR VICTOR VALLEY COLLEGE
MECHANICAL INFRASTRUCTURE ASSESSMENT FOR VICTOR VALLEY COLLEGE 18422 Bear Valley Road Victorville, CA 92395 Date 25 September 2012 dha Job No. 12155 TABLE OF CONTENTS I. Purpose.... Page 1 II. Existing
More informationAdding More Fan Power Can Be a Good Thing
This article was published in ASHE Journal, May 14. Copyright 14 ASHE. Posted at www.ashrae.org. This article may not be copied and/or distributed electronically or in paper form without permission of
More informationBOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:
4510 Helgesen Drive, Madison, WI, 53718 608.221.4499, 800.627.4499, Fax: 608.221.2824 support@renewaire.com www.renewaire.com RD2XIN INSTALLATION AND OPERATION MANUAL BOOK 1 OVERVIEW ABOUT BOOK 1: This
More informationAgenda and Objectives
Agenda and Objectives Trane Engineers Newsletter Live Series Variable-Speed Drives (VSDs) and Their Effect On HVAC System Components Variable-speed drives (VSDs) can save energy, but the savings may not
More informationMethod to test HVAC equipment at part load conditions
IPLV Method to test HVAC equipment at part load conditions For water cooled chillers: 100% load ( % hrs) + 75% ( Hrs ) + 50% ( Hrs ) + 25% ( Hrs ) = IPLV value Manufacturer can favor this number by tweaking
More informationHigh Efficiency Heating and Cooling Systems for Community Colleges Kirk Mescher, PE, LEED AP Principal ICCCFO
High Efficiency Heating and Cooling Systems for Community Colleges Kirk Mescher, PE, LEED AP Principal ICCCFO 2012 1 Learning Objectives for this Session Get acquainted with typical systems used in the
More informationSUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer
SUBMITTAL Project CLU Swenson Center Date 01/07/2010 Mechanical Contractor West Coast Air Conditioning Mechanical Engineer J & S Consulting Engineers, Inc. Revision Notes RTU-101, 102, 103, 201, 202, 203,
More informationENGINEERING BULLETIN. Overview of Chilled Beam Technology. Purpose. Summary. Theory
Overview of Chilled Beam Technology Purpose Chilled beam technology is new to the United States but has been used in Europe since the 1950 s. Chilled beams can reduce energy costs, improve indoor air quality,
More information