CADB/T-D DP25 F7 Series CADB/T-DI DP25 F7 CADB/T-DC DP25 F7. Heat recovery units CADB/T-D

Size: px
Start display at page:

Download "CADB/T-D DP25 F7 Series CADB/T-DI DP25 F7 CADB/T-DC DP25 F7. Heat recovery units CADB/T-D"

Transcription

1 CONFIGURLE cross-flow heat RECOVERY DP25 F7 Series I DP25 F7 C DP25 F7 housed in galvanised steel boxes, white plastic coated, with a 25 mm thick double wall, class M0 fire proof thermal and acoustic insulation, configurable inlets and outlets, versions for horizontal installation and for vertical installation, intakes with a hermetic seal, F7 filter for inlet air and G4 filter for air extraction. With two double inlet centrifugal fans with builtin motor. DP25 F7 Series Heat recovery without additional heat added. I DP25 F7 Series Heat recoveries with a heating resistance. C DP25 F7 Series Heat recoveries with a built-in hot water coil. Motors IP20, Class F (ranges 05, 08, 18 and 30). IP55, class F (ranges 45 and 56). IMPORTNT UPDTE TO THE RNGE New standard configuration with a 25 mm thick double wall and F7 filters with low loss of load, manufactured in polypropylene, for inlet air and G4 manufactured in fibreglass for extraction. dditional information Single phase (CD) and three phase models (CDT). Flows from 450 to 5,600 m 3 /h. Versions with an electronic microprocessor (SIC, PROGRM, DVNZ or DOMO) that enables the fan speed to be controlled. The versions with an electronic microprocessor in sizes 45 and 56 also incorporate a variable frequency drive. Horizontal and vertical versions, both with the possibility of a by-pass. ll side panels are interchangeable, which makes it possible to directly position the intake and outtake connections on site. P P L I C T I O N S Stores Offices Cafes, bars and restaurants Collective ventilation dwellings

2 Structural dvantages Vertical construction Low noise level Easy to mount Version with by pass Specific models for vertical installation. Internally lined with 25 mm M0 fire resistant acoustic insulation. Single phase models integrated hanging supports to install the heat recovery unit. Versions with by pass enabling 100% of the air to by pass the heat recovery (65% in singlephase versions). The by-pass works with a remotely activated servomotor with a manual switch (not included). 2 high-efficiency filters irtight connectors Robust construction Condensation drain 2 filters: F7 filter for inlet air (filtration efficiency: >80%). G4 filter for extracted air (efficiency: >90%). Pressure sockets Inlet and discharge circular duct connection flanges with integrated rubber air seal. External weatherproof terminal box High quality finishing with aluminium profile structure, providing a robust assembly. Drain pipe to evacuate water from condensation. Versions CD-D/DC/DI Regulation with an electronic microprocessor Pressure sockets before for clogging filter control. IP55 terminal box located on the outside of the heat recovery casing for easy wiring access. SIC PROGRM DVNZ DOMO Versions that incorporate an electronic microprocessor (SIC, PROGRM, DVNZ or DOMO) that enables fan speed control. The versions with an electronic microprocessor in sizes 45 and 56 also incorporate a variable frequency drive.

3 Structural dvantages Versatile assembly The design of these heat recovery units makes it possible for the user to configure them on site. ll side panels are interchangeable, which makes it possible to directly position the intake and outtake connections on site depending on the specific requirements. ll side panels are interchangeable

4 Structural dvantages Easy maintenance s CD- 05 / 08 / 18 / 30: Rapid access to the filters from the bottom and sides. Easy access for cleaning the heat recovery from the bottom. s CDT-45 and CDT-56: Rapid access to the filters from the top. It is also possible to access from the side and bottom. Easy access for cleaning the heat recovery from the top. Reference C D - D I 3 0 H T R I P D P 2 5 F 7 S I C V V CD / CDT: Series 2 - D: Standard range DI: Range with resistance incorporated DC:Range with water coil incorporated 3 - Size 4 -,, C, D, E, G, H: Type of configuration 5 - H: Horizontal unit V: Upright unit. 6 - MONO: Monophase support resistance. TRI: Three phase support resistance 7 - P: Version with by pass incorporated 8 - DP: Range with double wall insulation (25 mm). 9 - F7: ir inlet filter F SIC, PROGRM, DVNZ, DOMO Control Configuration control VV - Variable airflow CV - Constant airfflow (sizes 45 and 56) (Not posible with SIC) COP - Constant pressure (sizes 45 and 56) (Not possible with SIC)

5 Versions with an electronic microprocesor: s and functions SIC PROGRM DVNZ DOMO 1 Manual fan speed selection: OFF + 3 speed Manual fan speed selection: OFF + control of speed range [MIN-MX] (alternative to 1 ) Imbalance between impulsion and extraction flow only for VV versions with double inverter (does not apply to 3 speed versions) utomatic control of fan speed: CO 2, CO 2 /VOC and HR sensors with programmable PPM or HR range (by the installer); available for 3 speed versions and variable speed versions Remote function of the fan speed signal is 0-10V (alternative to 4 ) ooster via remote NC contact at a pre-set time. Time can be altered by software Remote "oost" management by NC contact or proximity sensor (alternative to 6 and 8 ) Unit can be switched ON/OFF via remote switch (alternative to 6 or 7 ) Weekly programs Prevention of icing of the heat exchanger (simple strategy): blower fan moves to low/off; Setting the extractor fan to maximum speed Prevention of build-up of frost in the heat exchanger: proportional mode management with pre-heating coils (alternative to 10 or 12 ) Exchanger frost prevention: Personalized funcions (through a switch NO-NC (alternative to 10 and 11 ) Management of electric post-heating (simple or double stage) in ON/OFF mode. The objective is to attain the average internal temperature value (Tr) 3 14 Management of electric post-heating in proportional mode. The objective is to attain the average internal temperature value (Tr) and to keep the impelled air within a set range (Ti) Management of water coil post-heating in ON/OFF mode. The objective is to attain the average internal temperature value (Tr) 3 16 Management of water coil post-heating. The objective is to attain the average internal temperature value (Tr) and to keep the impelled air within a set range (Ti) Management of post-cooling in proportional mode. The objective is to attain the average internal temperature value (Tr) and to keep the impelled air within a set range (Ti) Remote signalling of the status of the unit via a volt free contact: closed contact=the unit is operating; open contact=the unit is stopped (alternative to 12 ) Monitoring of the state of the filters via period of operation of the equipment or via differential pressure sensors Monitoring of the state of the fans via a tachometric signal (if supported by the fan) or via differential pressure sensors

6 Electronic microprocessors SIC model - Features and functions SIC CONTROL PRINCIPL FETURES Terminal cabinet includes: Proximity sensor Integrated circuit card and terminal box Remote control unit (100 m max.) Ready-mounted, ready-wired temperature sensors: Discharge temperature sensor (Tx) New air intake temperature sensor (Te) mbient air return temperature sensor (Tr) Vacuum regulator valve, ready-mounted and wired: Filter clogging Frequency regulator on Three phase models (sizes 45 and 56) OPTIONL FETURES Vacuum regulator valve, ready-mounted and wired: E-SCT circular battery Differential pressure switch Timer TG-K310 duct-mountable temperature sensor -20 to + 10ºC TI-10 potentiometer -20 to + 10ºC for panel mounting FUNCTIONS Flow rate adjustment: Manual fan speed selection: - Single phase models: 3 speed - Three phase models: 45%, 65% and 100% of maximum flow rate Free cooling function on models equipped with by-pass Prevention of icing of the heat exchanger: Heat exchanger antifreeze protection (blower fan moves to low/off) Safety functions: Filter clogging / vacuum regulator valve failure alarm Temperature sensor fault alarm (wire severed, connection fault,...) Console-control cabinet connection fault alarm Included, Unmounted option Schematic diagram CDT/T-D DP25 F7 with SIC control T discharge T new air intake Self-regulating antifreeze battery + y-pass T return (ambient) 0/VL/VM/VR SIC The battery is regulated independently. The SIC can not control it. oost HS/LS larms HS: High speed LS: Low speed

7 Electronic microprocessors - PROGRM model - Features and functions PROGRM CONTROL PRINCIPL FETURES Terminal cabinet includes: Proximity sensor Integrated circuit card and terminal box Remote control unit (100 m max.) Ready-mounted, ready-wired temperature sensors: Discharge temperature sensor (Tx) New air intake temperature sensor (Te) mbient air return temperature sensor (Tr) Vacuum regulator valve, ready-mounted and wired: Filter clogging Security (operation of fans) Frequency regulator on three phase models (sizes 45 and 56) OPTIONL FETURES CO2 sensor: SCO2-010 ambient sensor with display / SCO2-010G in-duct measurement Self-regulating antifreeze battery: E-SCT circular battery Differential pressure switch Timer TG-K310 duct-mountable temperature sensor -20 to + 10ºC TI-10 potentiometer -20 to + 10ºC for panel mounting FUNCTIONS Flow rate adjustment: Manual fan speed selection (single phase models) or variable (three phase models 45/56). Timer boost function utomatic modulation via built-in clock: daily and weekly programs utomatic speed settings (single phase models) or automatic speed variation (Three phase models) based on air quality sensor readings (sensor optional) Operates at constant pressure * Free cooling function on models equipped with by-pass Safety functions: Heat exchanger antifreeze protection (blower fan moves to low/off) Filter clogging / vacuum regulator valve failure alarm Temperature sensor fault alarm (wire severed, connection fault,...) Console-control cabinet connection fault alarm Included, Unmounted option * Optional and on request in 45 and 56 models Schematic diagram I DP25 F7 with PROGRM control T discharge T new air intake Self-regulating antifreeze battery + PROGRM CONTROL I C PRINCIPL FETURES Terminal cabinet includes: Proximity sensor Integrated circuit card and terminal box Remote control unit (100 m max.) Ready-mounted, ready-wired temperature sensors: Discharge temperature sensor (Tx) New air intake temperature sensor (Te) mbient air return temperature sensor (Tr) Supply air temperature sensor (Ti) Vacuum regulator valve, ready-mounted and wired: Filter clogging Security (operation of fans) Frequency regulator on three phase models (sizes 45 and 56) OPTIONL FETURES Motorized 3-way control valve + 230V/24V transformer for - hot water coil CO2 sensor: SCO2-010 ambient sensor with display / SCO2-010G in-duct measurement Self-regulating antifreeze battery: E-SCT circular battery Differential pressure switch Timer TG-K310 duct-mountable temperature sensor -20 to + 10ºC TI-10 potentiometer -20 to + 10ºC for panel mounting FUNCTIONS Flow rate adjustment: Manual fan speed selection (single phase models) or variable (three phase models 45/56). Timer boost function utomatic modulation via built-in clock: daily and weekly programs utomatic speed settings (single phase models) or automatic speed variation (Three phase models) based on air quality sensor readings (sensor optional) Operates at constant pressure * * Post heating battery regulation attery power regulation as per temperature setting and blower sensor reading Free cooling function on models equipped with by-pass Safety functions: Heat exchanger antifreeze protection (blower fan moves to low/off) Fan shutdown timer setting for cooling electric battery - (postventilation) Water coil antifreeze protection antigel de la batterie eau in each - sensor (opens 3-way control valve then stops power unit) Filter clogging / vacuum regulator valve failure alarm Temperature sensor fault alarm (wire severed, connection fault,...) Ventilation fault alarm Console-control cabinet connection fault alarm Included, - Not included, Unmounted option * Optional and on request in 45 and 56 models C DP25 F7 with PROGRM control T discharge + T new air intake Self-regulating antifreeze battery* + T supply air 0/HS/MS/LS y-pass PROGRM T return (ambient) T supply air 0/HS/MS/LS y-pass PROGRM T return (ambient) The battery is regulated independently. The PROGRM can not control it. CO2 Sensor Programmable timer oost HS/ Off HS/LS Setpoint adjustment larms CO2 Sensor Programmable timer oost HS/ Off HS/LS Setpoint adjustment larms HS: High speed MS: Medium speed LS: Low speed The battery is regulated independently. HS: High speed MS: Medium speed LS: Low speed The PROGRM can not control it.

8 Electronic microprocessors - DVNZ and DOMO models - Features and functions DVNZ ND DOMO CONTROLS PRINCIPL FETURES Terminal cabinet includes: Proximity sensor Integrated circuit card and terminal box Remote control unit (100 m max.) (Only DVNZ) Ready-mounted, ready-wired temperature sensors: Discharge temperature sensor (Tx) New air intake temperature sensor (Te) mbient air return temperature sensor (Tr) Vacuum regulator valve, ready-mounted and wired: Filter clogging Security (operation of fans) Frequency regulator on three phase models (sizes 45 and 56) OPTIONL FETURES CO2 sensor: SCO2-010 ambient sensor with display / SCO2-010G in-duct measurement Self-regulating antifreeze battery: E-SCT circular battery Differential pressure switch Timer TG-K310 duct-mountable temperature sensor -20 to + 10ºC TI-10 potentiometer -20 to + 10ºC for panel mounting FUNCTIONS Flow rate adjustment: Manual fan speed selection (single phase models) or variable (three phase models 45/56). Timer boost function utomatic modulation via built-in clock: daily and weekly programs utomatic speed settings (single phase models) or automatic speed variation (Three phase models) based on air quality sensor readings (sensor optional) Remote function of the fan speed signal is 0-10V Operates at constant pressure * Free cooling function on models equipped with by-pass Remote "oost" management by NC contact or proximity sensor Remote indication of unit status Exchanger frost prevention: Heat exchanger antifreeze protection (blower fan moves to low/off) Proportional management using an antifreeze battery (pre-heating)) Personalized funcions (through a switch NO-NC) Remote signaling of unit status Panel language configuration (ES/EN/DE/IT/FR) Safety functions: Filter clogging / vacuum regulator valve failure alarm Temperature sensor fault alarm (wire severed, connection fault,...) Console-control cabinet connection fault alarm Communicator regulation [adjustment] (Only DOMO) Included, Unmounted option * Optional and on request in 45 and 56 models Schematic diagram I DP25 F7 with DVNZ / DOMO control Supply air T discharge T new air intake Self-regulating antifreeze battery Register DVNZ ND DOMO CONTROLS I C PRINCIPL FETURES Terminal cabinet includes: Proximity sensor Integrated circuit card and terminal box Remote control unit (100 m max.) (Only DVNZ) Ready-mounted, ready-wired temperature sensors: Discharge temperature sensor (Tx) New air intake temperature sensor (Te) mbient air return temperature sensor (Tr) Supply air temperature sensor (Ti) Vacuum regulator valve, ready-mounted and wired: Filter clogging Security (operation of fans) Solid-state relay on electrical battery - No-frost safety sensor on hot water battery - Frequency regulator on three phase models (sizes 45 and 56) OPTIONL FETURES Motorized 3-way control valve + 230V/24V transformer for hot water coil - CO2 sensor: SCO2-010 ambient sensor with display / SCO2-010G in-duct measurement Self-regulating antifreeze battery: E-SCT circular battery Differential pressure switch Timer TG-K310 duct-mountable temperature sensor -20 to + 10ºC TI-10 potentiometer -20 to + 10ºC for panel mounting FUNCTIONS Flow rate adjustment: Manual fan speed selection (single phase models) or variable (three phase models 45/56). Timer boost function utomatic modulation via built-in clock: daily and weekly programs utomatic speed settings (single phase models) or automatic speed variation (Three phase models) based on air quality sensor readings (sensor optional) Remote function of the fan speed signal is 0-10V Operates at constant pressure * * Post heating battery regulation attery power regulation as per temperature setting and blower sensor reading Free cooling function on models equipped with by-pass Remote "oost" management by NC contact or proximity sensor Remote indication of unit status Exchanger frost prevention: Heat exchanger antifreeze protection (blower fan moves to low/off) Proportional management using an antifreeze battery (pre-heating) Personalized funcions (through a switch NO-NC) Proportional function of post-heating or post-cooling Remote signaling of unit status Panel language configuration (ES/EN/DE/IT/FR) Safety functions: Fan shutdown timer setting for cooling electric battery (postventilation) Water coil antifreeze protection antigel de la batterie eau in each sensor - (opens 3-way control valve then stops power unit) Filter clogging / vacuum regulator valve failure alarm Temperature sensor fault alarm (wire severed, connection fault,...) Console-control cabinet connection fault alarm Communicator regulation [adjustment] (Only DOMO) * Optional and on request in 45 and 56 models C DP25 F7 with DVNZ / DOMO control T supply air T discharge T new air intake Self-regulating antifreeze battery Register T return (ambient) T return (ambient) 0/HS/MS/LS DVNZ DOMO 0/HS/MS/LS DVNZ DOMO Network (DOMO) oost HR CO2 Sensor Programable timer oost HS / Off HS/LS Setpoint adjustment larms Network (DOMO) oost HS CO2 Sensor Programmable timer oost HR / Off HS/LS Setpoint adjustment larms HS: High speed MS: Medium speed LS: Low speed HS: High speed MS: Medium speed LS: Low speed

9 Technical characteristics s without heater Fan type Speed (r.p.m.) Nº of speeds Motor power (kw) Maximum absorbed current motor () Maximum absorbed current total () to 230V to 400V to 230V to 400V Maximum volume (m 3 /h) vailable pressure at maximum airflow (Pa) CD-D 05 DP25 F7 146-HR x 0,150 0,62-1, CD-D 08 DP25 F7 146-HT x 0,355 1,4-2, CD-D 18 DP25 F7 9/ x 0,373 2,75-5, CD-D 30 DP25 F7 10/ x 0, CDT-D 45 DP25 F7 10/ x 0,750-3,1-6, CDT-D 56 DP25 F7 12/ x 1,500-3,9-11, Protection IP s with integrated electrical heater Fan type Speed Nº of speeds Motor power Maximum absorbed current motor () Maximum Maximum absorbed current volume total () Protection IP Efficiency Resist. % power * Resist. voltage Resist. absorbed current (r.p.m.) (kw) to 230V to 400V to 230V to 400V (m 3 /h) (kw) (V) () () CD-DI 05 MONO DP25 F7 146-HR x 0,130 0,62-1, , ,5 9,74 CD-DI 08 MONO DP25 F7 146-HT x 0,310 1,4-2, , ,5 20,3 CD-DI 18 MONO DP25 F7 9/ x 0,373 2,75-5, , ,80 CD-DI 30 TRI DP25 F7 10/ x 0, , ,55 19,59 CDT-DI 45 TRI DP25 F7 10/ x 0,750-3,1-6, ,32 23,52 CDT-DI 56 TRI DP25 F7 12/ x 1,500-3,9-7, , ,32 25,12 * Values referring to the following conditions: Text air = -5ºC, Text exhaust air = +20ºC with RH exhaust air = 80% / max.airflow. Maximum current total fan + resistance s with integrated water coil (water 70/80ºC) Fan type Speed (r.p.m.) Nº of speeds Motor power (kw) Maximum absorbed current motor () Maximum absorbed current total () to 230V to 400V to 230V to 400V Maximum volume (m 3 /h) Protection IP Efficiency Thermal % performance * CD-DC 05 DP25 F7 146-HR x 0,130 0,62-1, ,7 2,62 CD-DC 08 DP25 F7 146-HT x 0,310 1,4-2, ,9 3,67 CD-DC 18 DP25 F7 9/ x 0,373 2,75-5, ,6 10,67 CD-DC 30 DP25 F7 10/ x 0, ,5 14,29 CDT-DC 45 DP25 F7 10/ x 0,750-3,1-6, CDT-DC 56 DP25 F7 12/ x 1,500-3,9-7, ,3 34,5 * Values referring to the following conditions: Text air = -5ºC, Text exhaust air = +20ºC with RH exhaust air = 80% / max.airflow. ** Values referring to the following conditions: water 70/80ºC, intake air temperature +8ºC nominal airflow. (kw) ** Evolution of the efficiency of recovery according to the flow Efficiency CD 05 CD 08 CD 18 CD 30 CDT 45 CDT 56 Values with the following conditions: Outside air temperature -5ºC, inside air temperature +20ºC with interior RH of 80%. irflow (m 3 /h)

10 Thermal efficiency recovery ir volume (m 3 /h) ºC CD-D 05 DP25 F CD-D 08 DP25 F CD-D 18 DP25 F CD-D 30 DP25 F CDT-D 45 DP25 F CDT-D 56 DP25 F T. ambient air T. outdoor air T. air treated H.R. % ºC H.R. % (ºC) Minimum efficiency (%) Power (kw) ,6 52,2 2, ,7 50,7 2, ,4 46,9 1, ,7 44,9 1, ,7 2, ,6 54,4 2, ,5 52,5 1, ,1 47,4 1, ,6 55,4 4, ,5 53,9 3, ,8 2, ,1 47,4 1, ,1 4, ,5 57, ,2 55,8 3, ,5 50,3 2, ,9 53,1 10, ,9 51,6 8, ,5 47,7 6, ,8 45,6 4, ,3 57,7 11, ,8 55, ,7 53,4 6, ,2 48,2 4, , , ,1 52,5 13, ,7 48,5 9, ,9 46,3 7, ,6 58, ,1 56,4 14, ,9 54,4 11, ,4 49,1 7, ,6 55, , , ,1 50,2 15, ,1 47,6 10, ,1 60,3 27, ,8 59,3 22, ,3 56, ,8 51,7 11, ,3 54,5 31, ,1 52,3 25, ,8 48,8 18, ,9 46,1 13, ,5 58,5 34, ,4 57,5 27, ,9 54,5 21, , ,6

11 Complete chart for standard versions HORIZONTL Range 05 CD-D 05 CH DP25 F7 CD-D 05 CH P DP25 F7 Range 08 CD-D 08 CH DP25 F7 CD-D 08 CH P DP25 F7 Range 18 CD-D 18 CH DP25 F7 CD-D 18 CH P DP25 F7 Range 30 CD-D 30 CH DP25 F7 CD-D 30 CH P DP25 F7 Range 45 CDT-D 45 CH DP25 F7 CDT-D 45 CH P DP25 F7 Range 56 CDT-D 56 CH DP25 F7 CDT-D 56 CH P DP25 F7 UPRIGHT Range 05 CD-D 05 V DP25 F7 CD-D 05 V P DP25 F7 Range 08 CD-D 08 V DP25 F7 CD-D 08 V P DP25 F7 Range 18 CD-D 18 V DP25 F7 CD-D 18 V P DP25 F7 Range 30 CD-D 30 V DP25 F7 CD-D 30 V P DP25 F7 Range 45 CDT-D 45 V DP25 F7 CDT-D 45 V P DP25 F7 Range 56 CDT-D 56 V DP25 F7 CDT-D 56 V P DP25 F7 CD-D 05 V DP25 F7 CD-D 05 V P DP25 F7 CD-D 08 V DP25 F7 CD-D 08 V P DP25 F7 CD-D 18 V DP25 F7 CD-D 18 V P DP25 F7 CD-D 30 V DP25 F7 CD-D 30 V P DP25 F7 CDT-D 45 V DP25 F7 CDT-D 45 V P DP25 F7 CDT-D 56 V DP25 F7 CDT-D 56 V P DP25 F7 CD-D 05 HV DP25 F7 CD-D 05 HV P DP25 F7 CD-D 08 HV DP25 F7 CD-D 08 HV P DP25 F7 CD-D 18 HV DP25 F7 CD-D 18 HV P DP25 F7 CD-D 30 HV DP25 F7 CD-D 30 HV P DP25 F7 CDT-D 45 HV DP25 F7 CDT-D 45 HV P DP25 F7 CDT-D 56 HV DP25 F7 CDT-D 56 HV P DP25 F7 I HORIZONTL Range 05 CD-DI 05 H MONO DP25 F7 CD-DI 05 DH MONO DP25 F7 CD-DI 05 EH MONO DP25 F7 CD-DI 05 GH MONO DP25 F7 Range 08 CD-DI 08 H MONO DP25 F7 CD-DI 08 DH MONO DP25 F7 CD-DI 08 EH MONO DP25 F7 CD-DI 08 GH MONO DP25 F7 Range 18 CD-DI 18 H MONO DP25 F7 CD-DI 18 DH MONO DP25 F7 CD-DI 18 EH MONO DP25 F7 CD-DI 18 GH MONO DP25 F7 Range 30 CD-DI 30 H TRI DP25 F7 CD-DI 30 DH TRI DP25 F7 CD-DI 30 EH TRI DP25 F7 CD-DI 30 GH TRI DP25 F7 Range 45 CDT-DI 45 H TRI DP25 F7 CDT-DI 45 DH TRI DP25 F7 CDT-DI 45 EH TRI DP25 F7 CDT-DI 45 GH TRI DP25 F7 Range 56 CDT-DI 56 H TRI DP25 F7 CDT-DI 56 DH TRI DP25 F7 CDT-DI 56 EH TRI DP25 F7 CDT-DI 56 GH TRI DP25 F7 CD-DI 05 H MONO P DP25 F7 CD-DI 05 DH MONO P DP25 F7 CD-DI 05 EH MONO P DP25 F7 CD-DI 05 GH MONO P DP25 F7 CD-DI 08 H MONO P DP25 F7 CD-DI 08 DH MONO P DP25 F7 CD-DI 08 EH MONO P DP25 F7 CD-DI 08 GH MONO P DP25 F7 CD-DI 18 H MONO P DP25 F7 CD-DI 18 DH MONO P DP25 F7 CD-DI 18 EH MONO P DP25 F7 CD-DI 18 GH MONO P DP25 F7 CD-DI 30 H TRI P DP25 F7 CD-DI 30 DH TRI P DP25 F7 CD-DI 30 EH TRI P DP25 F7 CD-DI 30 GH TRI P DP25 F7 CDT-DI 45 H TRI P DP25 F7 CDT-DI 45 DH TRI P DP25 F7 CDT-DI 45 EH TRI P DP25 F7 CDT-DI 45 GH TRI P DP25 F7 CDT-DI 56 H TRI P DP25 F7 CDT-DI 56 DH TRI P DP25 F7 CDT-DI 56 EH TRI P DP25 F7 CDT-DI 56 GH TRI P DP25 F7 UPRIGHT Range 05 CD-DI 05 CV MONO DP25 F7 CD-DI 05 DV MONO DP25 F7 CD-DI 05 EV MONO DP25 F7 Range 08 CD-DI 08 CV MONO DP25 F7 CD-DI 08 DV MONO DP25 F7 CD-DI 08 EV MONO DP25 F7 Range 18 CD-DI 18 CV MONO DP25 F7 CD-DI 18 DV MONO DP25 F7 CD-DI 18 EV MONO DP25 F7 Range 30 CD-DI 30 CV TRI DP25 F7 CD-DI 30 DV TRI DP25 F7 CD-DI 30 EV TRI DP25 F7 Range 45 CDT-DI 45 CV TRI DP25 F7 CDT-DI 45 DV TRI DP25 F7 CDT-DI 45 EV TRI DP25 F7 Range 56 CDT-DI 56 CV TRI DP25 F7 CDT-DI 56 DV TRI DP25 F7 CDT-DI 56 EV TRI DP25 F7 CD-DI 05 CV MONO P DP25 F7 CD-DI 05 DV MONO P DP25 F7 CD-DI 05 EV MONO P DP25 F7 CD-DI 08 CV MONO P DP25 F7 CD-DI 08 DV MONO P DP25 F7 CD-DI 08 EV MONO P DP25 F7 CD-DI 18 CV MONO P DP25 F7 CD-DI 18 DV MONO P DP25 F7 CD-DI 18 EV MONO P DP25 F7 CD-DI 30 CV TRI P DP25 F7 CD-DI 30 DV TRI P DP25 F7 CD-DI 30 EV TRI P DP25 F7 CDT-DI 45 CV TRI P DP25 F7 CDT-DI 45 DV TRI P DP25 F7 CDT-DI 45 EV TRI P DP25 F7 CDT-DI 56 CV TRI P DP25 F7 CDT-DI 56 DV TRI P DP25 F7 CDT-DI 56 EV TRI P DP25 F7 C HORIZONTL Range 05 CD-DC 05 H DP25 F7 CD-DC 05 DH DP25 F7 CD-DC 05 EH DP25 F7 CD-DC 05 GH DP25 F7 CD-DC 05 H P DP25 F7 CD-DC 05 DH P DP25 F7 CD-DC 05 EH P DP25 F7 CD-DC 05 GH P DP25 F7 Range 08 CD-DC 08 H DP25 F7 CD-DC 08 DH DP25 F7 CD-DC 08 EH DP25 F7 CD-DC 08 GH DP25 F7 CD-DC 08 H P DP25 F7 CD-DC 08 DH P DP25 F7 CD-DC 08 EH P DP25 F7 CD-DC 08 GH P DP25 F7 Range 18 CD-DC 18 H DP25 F7 CD-DC 18 DH DP25 F7 CD-DC 18 EH DP25 F7 CD-DC 18 GH DP25 F7 CD-DC 18 H P DP25 F7 CD-DC 18 DH P DP25 F7 CD-DC 18 EH P DP25 F7 CD-DC 18 GH P DP25 F7 Range 30 CD-DC 30 H DP25 F7 CD-DC 30 DH DP25 F7 CD-DC 30 EH DP25 F7 CD-DC 30 GH DP25 F7 CD-DC 30 H P DP25 F7 CD-DC 30 DH P DP25 F7 CD-DC 30 EH P DP25 F7 CD-DC 30 GHP DP25 F7 Range 45 CDT-DC 45 H DP25 F7 CDT-DC 45 DH DP25 F7 CDT-DC 45 EH DP25 F7 CDT-DC 45 GH DP25 F7 CDT-DC 45 H P DP25 F7 CDT-DC 45 DH P DP25 F7 CDT-DC 45 EH P DP25 F7 CDT-DC 45 GH P DP25 F7 Range 56 CDT-DC 56 H DP25 F7 CDT-DC 56 DH DP25 F7 CDT-DC 56 EH DP25 F7 CDT-DC 56 GH DP25 F7 CDT-DC 56 H P DP25 F7 CDT-DC 56 DH P DP25 F7 CDT-DC 56 EH P DP25 F7 CDT-DC 56 GH P DP25 F7 UPRIGHT Range 05 CD-DC 05 CV DP25 F7 CD-DC 05 DV DP25 F7 CD-DC 05 EV DP25 F7 CD-DC 05 CV P DP25 F7 CD-DC 05 DV P DP25 F7 CD-DC 05 EV P DP25 F7 Range 08 CD-DC 08 CV DP25 F7 CD-DC 08 DV DP25 F7 CD-DC 08 EV DP25 F7 CD-DC 08 CV P DP25 F7 CD-DC 08 DV P DP25 F7 CD-DC 08 EV P DP25 F7 Range 18 CD-DC 18 CV DP25 F7 CD-DC 18 DV DP25 F7 CD-DC 18 EV DP25 F7 CD-DC 18 CV P DP25 F7 CD-DC 18 DV P DP25 F7 CD-DC 18 EV P DP25 F7 Range 30 CD-DC 30 CV DP25 F7 CD-DC 30 DV DP25 F7 CD-DC 30 EV DP25 F7 CD-DC 30 CV P DP25 F7 CD-DC 30 DV P DP25 F7 CD-DC 30 EV P DP25 F7 Range 45 CDT-DC 45 CV DP25 F7 CDT-DC 45 DV DP25 F7 CDT-DC 45 EV DP25 F7 CDT-DC 45 CV P DP25 F7 CDT-DC 45 DV P DP25 F7 CDT-DC 45 EV P DP25 F7 Range 56 CDT-DC 56 CV DP25 F7 CDT-DC 56 DV DP25 F7 CDT-DC 56 EV DP25 F7 CDT-DC 56 CV P DP25 F7 CDT-DC 56 DV P DP25 F7 CDT-DC 56 EV P DP25 F7

12 /DI/DC DP25 F7 standard configurations ase on these standard configurations other configurations can be quickly and simply adapted by the installer. NEW IRE IRNUEVO EXTRCTED IRE EXTRIDO IR HORIZONTL UPRIGHT CD-D 05/08/18/30 CH CDT-D 45/56 CH CD-D 05/08/18/30 V CDT-D 45/56 V CD-D 05/08/18/30 V CDT-D 45/56 V CD-D 05/08/18/30 HV CDT-D 45/56 HV Conf. CH Conf. V Conf. V Conf. HV I HORIZONTL CD-DI 05/08/18 H MONO CD-DI 30 H TRI CDT-DI 45/56 H TRI CD-DI 05/08/18 DH MONO CD-DI 30 DH TRI CDT-DI 45/56 DH TRI CD-DI 05/08/18 EH MONO CD-DI 30 EH TRI CDT-DI 45/56 EH TRI CD-DI 05/08/18 GH MONO CD-DI 30 GH TRI CDT-DI 45/56 GH TRI Co n f. H Co n f. DH Co n f. EH Co n f. GH UPRIGHT CD-DI 05/08/18 CV MONO CD-DI 30 CV TRI CDT-DI 45/56 CV TRI CD-DI 05/08/18 DV MONO CD-DI 30 DV TRI CDT-DI 45/56 DV TRI CD-DI 05/08/18 EV MONO CD-DI 30 EV TRI CDT-DI 45/56 EV TRI Co n f. CV Co n f. DV Co n f. EV

13 /DI/DC DP25 F7 standard configurations NEW IRE IRNUEVO C EXTRCTED IRE EXTRIDO IR HORIZONTL CD-DC 05/08/18/30 H CDT-DC 45/56 H CD-DC 05/08/18/30 DH CDT-DC 45/56 DH CD-DC 05/08/18/30 EH CDT-DC 45/56 EH CD-DC 05/08/18/30 GH CDT-DC 45/56 GH Conf. H Conf. DH Conf. EH Conf. GH UPRIGHT CD-DC 05/08/18/30 CV CDT-DC 45/56 CV CD-DC 05/08/18/30 DV CDT-DC 45/56 DV CD-DC 05/08/18/30 EV CDT-DC 45/56 EV Conf. CV Conf. DV Conf. EV

14 DP25 F7. Dimensions (mm) Electrical panel dimensions for all versions CD-D/DC/DI Regulation with an electronic microprocessor (SIC, PROGRM, DVNZ or DOMO). * The electrical panel is installed in the side panel fan drive. Horizontal configuration (H) C Ø D E a b h Weight (Kg) CD-D , CD-D CD-D CD-D , CDT-D , CDT-D , b b a a C C ø ø h h D D ø1/2" ø1/2" E E * The electrical panel is installed in the side panel fan drive. Horizontal configuration (H) con by-pass (P) C Ø D E a b h Weight (Kg) CD-D , CD-D CD-D CD-D , CDT-D , CDT-D ,

15 DP25 F7. Dimensions (mm) Electrical panel dimensions for all versions CD-D/DC/DI Regulation with an electronic microprocessor (SIC, PROGRM, DVNZ or DOMO). C C b b D D a a E E h h ø ø F F ø1/2" ø1/2" * The electrical panel is installed in the side panel fan drive, can be positioned up, down, right or left (depending on configuration of the heat recovery). Upright configuration (V) C Ø D E F a b h Weight (Kg) CD-D , CD-D CD-D CD-D CDT-D , CDT-D , C C b b D D a a E E h h ø ø F F ø1/2" ø1/2" * The electrical panel is installed in the side panel fan drive, can be positioned up, down, right or left (depending on configuration of the heat recovery). Upright configuration (V) con by-pass (P) C Ø D E F a b h Weight (Kg) CD-D , CD-D CD-D CD-D CDT-D , CDT-D ,

16 I-DC DP25 F7. Dimensions (mm) Electrical panel dimensions for all versions CD-D/DC/DI Regulation with an electronic microprocessor (SIC, PROGRM, DVNZ or DOMO). b a ør ø C h D E ø1/2" * The electrical panel is installed in the side panel fan drive. Horizontal configuration (H) C Ø D E ØR a b h Weight (Kg) CD-DI-DC , /2" CD-DI-DC /2" CD-DI-DC /2" CD-DI-DC ,5 1" CDT-DI-DC , " CDT-DI-DC , " b a ø C ør h D ø1/2" E * The electrical panel is installed in the side panel fan drive. Horizontal configuration (H) con by-pass (P) C Ø D E ØR a b h Weight (Kg) CD-DI-DC , /2" CD-DI-DC /2" CD-DI-DC /2" CD-DI-DC ,5 1" CDT-DI-DC , " CDT-DI-DC , "

17 I-DC DP25 F7. Dimensions (mm) Electrical panel dimensions for all versions CD-D/DC/DI Regulation with an electronic microprocessor (SIC, PROGRM, DVNZ or DOMO). C b D a E h ør ø F 100 ø1/2" * The electrical panel is installed in the side panel fan drive, can be positioned up, down, right or left (depending on configuration of the heat recovery). Upright configuration (V) C Ø D E F ØR a b h Weight (Kg) CD-DI-DC , /2" CD-DI-DC /2" CD-DI-DC /2" CD-DI-DC " CDT-DI-DC , " CDT-DI-DC , " C b D a E h ør ø 100 F ø1/2" * The electrical panel is installed in the side panel fan drive, can be positioned up, down, right or left (depending on configuration of the heat recovery). Upright configuration (V) con by-pass (P) C Ø D E F ØR a b h Weight (Kg) CD-DI-DC , /2" CD-DI-DC /2" CD-DI-DC /2" CD-DI-DC , " CDT-DI-DC , " CDT-DI-DC , "

18 Performance curves Qv = Volume in m 3 /h. Ps = Static pressure in mmwg and Pa Pabs = Power absorbed at the maximum velocity (W). Normal dry air at 20 C and 760 mmhg Performance data in accordance with ISO 5801 and MC Standards. dditional pressure drop Resistances: ll 10 Pa models. atteries: 05 Range 16Pa, 08 Range 13Pa, 18 Range 31Pa, 30 Range 27Pa, 45 Range 60Pa, 56 Range 100Pa. Pe Ps Pa mmwg mmca V3 V4 V2 V1 CD-D/DI/DC 05 Pabs ( W ) Qv (m 3 /h) Eff. Rend (%)( % ) V1 Ps Pe Pa mmwg mmca V4 V1 V2 V3 CD-D/DI/DC 08 Pabs ( W ) Qv (m 3 /h) Eff. Rend (%)( % ) V Ps mmwg CD-D/DI/DC 18 Ps CD-D/DI/DC 30 mmwg Eff. (%) Eff. (%) Ps mmwg CDT-D/DI/DC 45 Ps Pe Pa mmwg mmca CD-D/DI/DC 56 Pabs ( W ) Eff. (%) Qv (m 3 /h) Eff. Rend (%)( % )

19 coustical characteristics Lw, levels of noise transmitted in the inlet conduit and radiated in accordance with regulation EN ISO Noise transmitted CD-D d() L W V 1 21,5 17, L W V 2 28,5 23, L W V 3 33,5 29, L W V 4 38,5 35, Noise radiated CD-D d() L W V 1 15,5 13, L W V 2 21,5 18, L W V 3 26,5 23, L W V 4 30,5 28, Noise transmitted CD-D d() L W V 1 30,5 25, L W V 2 36,5 33, L W V 3 40,5 38, L W V 4 43,5 41, Noise radiated CD-D d() L W V 1 23,5 20, L W V 2 28,5 27, L W V 3 32,5 31, L W V 4 34,5 33, Noise transmitted CD-D d() L W V 1 49,5 48, L W V 2 52,5 51, L W V 3 51,5 53, Noise radiated CD-D d() L W V 1 39,5 39, L W V 2 42,5 42, L W V 3 41,5 44, Noise transmitted CD-D d() L W V 1 40,5 41, L W V 2 53,5 50, L W V 3 55,5 62, Noise radiated CD-D d() L W V 1 32,5 33, L W V 2 42,5 41, L W V 3 44,5 51, Noise transmitted CDT-D d() L W V max 66,5 67, Noise radiated CDT-D d() L W V max 62,5 61, Noise transmitted CDT-D d() L W V max 68,5 69, Noise radiated CDT-D d() L W V max 64,5 62, Mounting accessories FR Spare filter Spare filter Spare filter G4 Spare filter F7 Spare filter F9 CD-D/DI/DC 05 FR-D/DI/DC 05 G4 FR-D/DI/DC 05 F7 FR-D/DI/DC 05 F9 CD-D/DI/DC 08 FR-D/DI/DC 08 G4 FR-D/DI/DC 08 F7 FR-D/DI/DC 08 F9 CD-D/DI/DC 18 FR-D/DI/DC 18 G4 FR-D/DI/DC 18 F7 FR-D/DI/DC 18 F9 CD-D/DI/DC 30 FR-D/DI/DC 30 G4 FR-D/DI/DC 30 F7 FR-D/DI/DC 30 F9 CDT-D/DI/DC 45 FR-D/DI/DC 45/56 G4 FR-D/DI/DC 45/56 F7 FR-D/DI/DC 45/56 F9 CDT-D/DI/DC 56 FR-D/DI/DC 45/56 G4 FR-D/DI/DC 45/56 F7 FR-D/DI/DC 45/56 F9

20 Mounting accessories CFIL* Filtering box PC Inlet/discharge protection guards CD-D/DI/DC 05 CD-D/DI/DC 08 CD-D/DI/DC 18 CD-D/DI/DC 30 CD-D/DI/DC 45 CD-D/DI/DC 56 Filtering box CFIL-200 CFIL-250 CFIL-315 CFIL-355 CFIL-450 CFIL-450 CD-D/DI/DC 05 CD-D/DI/DC 08 CD-D/DI/DC 18 CD-D/DI/DC 30 CD-D/DI/DC 45 CD-D/DI/DC 56 Inlet/discharge protection guards PC-200 PC-250 PC-315 PC-355 PC-450 PC-450 MSO Flexible coupling CD-D/DI/DC 05 CD-D/DI/DC 08 CD-D/DI/DC 18 CD-D/DI/DC 30 CD-D/DI/DC 45 CD-D/DI/DC 56 Flexible coupling MSO-200 MSO-250 MSO-315 MSO-355 MSO-450 MSO-450 SIL Sound attenuators to mount at the inlet and/or discharge of the heat recovery units CD-D/DI/DC 05 CD-D/DI/DC 08 CD-D/DI/DC 18 CD-D/DI/DC 30 CD-D/DI/DC 45 CD-D/DI/DC 56 Sound attenuator SIL-200 SIL-250 SIL-315 SIL-355 SIL-450 SIL-450 SIFÓN RECUPERDORES* Drain water drainage of the heat recovery TPP External rain protection canopy TPP D-H Rain Cap CD-D 05 H TPP D-H 05 CD-D 08 H TPP D-H 08 CD-D 18 H TPP D-H 18 CD-D 30 H TPP D-H 30 CDT-D 45 H TPP D-H 45/56 CDT-D 56 H TPP D-H 45/56 TPP D-V Rain Cap CD-D 05 V TPP D-V 05 CD-D 08 V TPP D-V 08 CD-D 18 V TPP D-V 18 CD-D 30 V TPP D-V 30 CDT-D 45 V TPP D-V 45/56 CDT-D 56 V TPP D-V 45/56 TPP DI/DC-H Rain Cap CD-DI/DC 05 H TPP DI/DC-H 05 CD-DI/DC 08 H TPP DI/DC-H 08 CD-DI/DC 18 H TPP DI/DC-H 18 CD-DI/DC 30 H TPP DI/DC-H 30 CDT-DI/DC 45 H TPP DI/DC-H 45/56 CDT-DI/DC 56 H TPP DI/DC-H 45/56 TPP DI/DC-V Rain Cap CD-DI/DC 05 V TPP DI/DC-V 05 CD-DI/DC 08 V TPP DI/DC-V 08 CD-DI/DC 18 V TPP DI/DC-V 18 CD-DI/DC 30 V TPP DI/DC-V 30 CDT-DI/DC 45 V TPP DI/DC-V 45/56 CDT-DI/DC 56 V TPP DI/DC-V 45/56 TTP D/DI/DC P To heat recovery horizontal with by-pass CD-D 05 H P CD-D 08 H P CD-D 18 H P CD-D 30 H P CD-DI/DC 05 H P CD-DI/DC 08 H P CD-DI/DC 18 H P CD-DI/DC 30 H P Rain Cap TPP D-H 05 P TPP D-H 08 P TPP D-H 18 P TPP-D-H 30 P TPP-DI/DC-H 05 P TPP-DI/DC-H 08 P TPP-DI/DC-H 18 P TPP-DI/DC-H 30 P See complete information on the HET RECOVERY CCESSORIES.

21 Mounting accessories Versions CD-D 05 H to 30 H with by-pass 5º 5º Versions CD-D 05 H to 30 H without by-pass Versions CDT-D 45 H and 56 H with and without by-pass 5º Versions V with and without by-pass External rain protection canopy incorporates 4 side panels CD-D 05 H CD-D 08 H CD-D 18 H CD-D 30 H CDT-D 45 H CDT-D 56 H CD-D 05 V CD-D 08 V CD-D 18 V CD-D 30 V CDT-D 45 V CDT-D 56 V Versions CD-DI/DC 05 H to 30 H with by-pass 5º 5º Versions CD-DI/DC 05 H to 30 H without by-pass Versions CDT-DI/DC 45 H and 56 H with and without by-pass External rain protection canopy incorporates 4 side panels 5º Versions I/DC V with and without by-pass CD-DI/DC 05 H CD-DI/DC 08 H CD-DI/DC 18 H CD-DI/DC 30 H CDT-DI/DC 45 H CDT-DI/DC 56 H CD-DI/DC 05 V CD-DI/DC 08 V CD-DI/DC 18 V CD-DI/DC 30 V CDT-DI/DC 45 V CDT-DI/DC 56 V

22 Electrical accessories ccessories for the Variable ir Volume System by CO2 Variable frequency drive Sensor CD-D/DI/DC 05 RQ3 SCO2- / SCO2-D / SCO2-G CD-D/DI/DC 08 RQ3 SCO2- / SCO2-D / SCO2-G CD-D/DI/DC 18 VPZ-11 SCO2- / SCO2-D / SCO2-G CD-D/DI/DC 30 VPZ-11 SCO2- / SCO2-D / SCO2-G CD-D/DI/DC 45 VFTM TRI 2,2 SCO2- / SCO2-D / SCO2-G CD-D/DI/DC 56 VFTM TRI 4 SCO2- / SCO2-D / SCO2-G ccessories for Constant Pressure operation Variable frequency drive Sensor CD-D/DI/DC 05 Pack PR Pa Included CD-D/DI/DC 08 Pack PR Pa Included CD-D/DI/DC 18 Pack PR Pa Included CD-D/DI/DC 30 Pack PR Pa Included CD-D/DI/DC 45 VFTM TRI 2,2 TDP-S / TDP-D CD-D/DI/DC 56 VFTM TRI 4 TDP-S / TDP-D RQ3 utomatic speed adjustment according to CO 2 concentration. Works together with a CO 2 probe (SCO2-1/10V ambient and, SCO2-D or in the SCO2-G conduit). Only for 05 and 08 models. VFTM TRI Variable frequency drive enabling the fan speed to be modified according to CO 2 concentration. Works together with a CO 2 probe (SCO2- ambient and SCO2-D or in the SCO2-G conduit). Only for 45 and 56 models. Pack PR Voltage regulator for single-phase motors with pressure probe included for control of constant pressure systems. VPZ-11 Controller, enabling the fan speed to be modified according to CO 2 concentration. Maximum current 11. Works together with a CO 2 probe (SCO2- ambient and, SCO2- and SCO2-D or in the SCO2-G conduit). Only for 18 and 30 models. Electrical supply Maximum current () Voltage (V) IP Operating temp. range Dimensions LxxH (mm) Pack PR 5 230V-50/60Hz IP55-10 to x200x80 Pack PR V-50/60Hz IP55-10 to x200x80 Electrical supply Maximum current () Voltage (V) IP Operating temperature range Dimensions LxxH (mm) VPZ V-50Hz IP55-10 to x115x92 Electrical supply Maximum power (V) TDP-S / TDP-D Pressure sensor. Enables you to control the pressure in the fan inlet. TDP-S Standard pressure sensor. TDP-D Pressure sensor, with display. Ø Connectors (mm) TDP-S 0-10 V / 24VC-24VDC 4 6,2 TDP-D 4-20 m Voltage IP Pressure range (Pa) Dimensions LxxH (mm) IP x36x80 SCO2-G 0/10 V CO2 sensor probe for duct mounting. Enable control of the ventilation in ductwork according to the CO 2 concentration of the air circulating through it. Electrical supply SCO2-0/10 V 24VDC- 24VC SCO2-D Power (W) 5 SCO2-0/10 V mbient CO 2 and temperature sensor. Enables control of the ventilation in sections of conduit according to the temperature and relative humidity of the air circulating through it or to the temperature. SCO2-D mbient CO 2 and temperature sensor with display. Enable control of the ventilation ductwork according to the temperature and relative humidity of the air circulating through it or to the temperature. Voltage Height instal. (m) IP CO 2 range (pm) For controlled equipment only a 0-10 V probe can be connected. Temperature range (ºC) Dimensions LxxH (mm) 0-10V 1,5-3,5 IP x26x m SCO2-G 0/10 V Electrical supply Power (W) Voltage (V) IP CO 2 range (pm) Dimensions LxxH (mm) 24VDC-24VC ox IP x238x80

23 Electrical accessories COM3 / COM4 3 and 4 speed switch SQ utomatically switches the fan on when the quality of the ambient air deteriorates below an acceptable level due to fumes, odours, tobacco, smoke or dampness etc djustable run-on-timer facility which enables the fan to operate for a pre-selected time period after the air quality sensor has switched off. Important: this sensor must not be used to detect combustible gases or fires ans in connection with any safety alarm systems. Switch Maximum current () CD-D/DI/DC 05 COM4 12 CD-D/DI/DC 08 COM4 12 CD-D/DI/DC 18 COM3 20 CD-D/DI/DC 30 COM3 20 IP protection Class Maximum current () Operating temperature (ºC) Timer adjustment IP21 II ( ) 2* min. * For inductive loads. PULSER Electronic controller to regulate the heat output for single phase electric heater battery up to 16, in order to maintain a constant pre-selected temperature. Depending on the selected temperature, the controller pulses the entire power output anduses a time-proportional control to maintain that temperature. The PULSER incorporates a built-in room temperature sensor with an input for external sensor. IP-30. Maximum heaterpower 3,6kW. TTC-25 Electronic controller to regulate the heat output for three phase electric heater battery up to 25, in order to maintain a constant pre-selected temperature. Depending on the selected temperature, the controller pulses the entire power output and uses a time-proportional control to maintain that temperature. The TTC-25 is designed to be fitted in a cabinet on DIN-rail. IP-20. PULSER-DD Supplementary unit for slave control from another PULSER to control batteries with power ratings superior to the PULSER capacity (3600W V). PULSER M Electronic controller similar to the PULSER, incorporating in addition, input for an external duct sensor to control minimum or maximum temperature limitations. IP-30. Maximum heaterpower 3,6kW. PULSER D Electronic controller to regulate the heat output for single phase electric heater battery up to 16, in order to maintain a constant pre-selected temperature. Depending on the selected temperature, the controller pulses the entire power output and uses a time-proportional control to maintain that temperature. The PULSER D is designed to be fitted in a cabinet on DIN-rail. IP-20. Maximum heater power 3,6kW.). TG-R430 Room sensor with set point adjustment between 0 and +30ºC. TI-10 Potentiometer mounted on the main board panel for setting temperature between -20 and +10ºC. Used with the PULSER-D or TTC-25 mounted within cabinet, to set the minimum air temperature before entering in the heat exchanger.

24 Electrical accessories TI-30 Potentiometer mounted on the main board panel for setting temperature between 0 and +30ºC. Used with the Pulser-D and with a TTC-25 duct sensor to set the air temperature after the electric battery in post heating operation. MCR-1 Timer with set point between 1 sec and 100 h. Used in an electric heating system to delay the fan switch off after disconnecting the system. PRESSURE SWITCH DPS 2-30 Differential pressure switch to control the fan running and the filter clogging up. Working pressure range from 2 to 30 mmwg. TG-K310, TG-K330 and TG-K360 Duct temperature sensor. Temperature range: TG-K310 from -20 to 10ºC TG-K330 from 0 to 30ºC TG-K360 from 0 to 60ºC 3WV C* Motorized 3-way valves. TRNSFORMER C Transformer 200V / 24V C for vales supply. Valve DN (mm) DN (") Kvs (m 3 /h) CD-D/DI/DC 05 3 WV CD-DC 05/ /2 2,5 CD-D/DI/DC 08 3 WV CD-DC 08/ /2 1,6 CD-D/DI/DC 18 3 WV CD-DC 08/ /2 1,6 CD-D/DI/DC 30 3 WV CD-DC 05/ /2 2,5 CDT-D/DI/DC 45 3 WV CDT-DC 45/ /4 6,3 CDT-D/DI/DC 56 3 WV CDT-DC 45/ /4 6,3 * See complete information on the HET RECOVERY CCESSORIES.

25 mbient temperature and inlet air temperature control Heat recovery DP25 F7 Electric heating batteries with built-in temperature control to fit on versions : consists of electric resistances, conduit probe, electric battery regulator and internal potentiometer. Heat recovery Ø (mm) Power (W) Voltage Nº stages Minimum airflow (m 3 /h) E-SCT 200M CD-D V-1-50Hz E-SCT 250M CD-D V-1-50Hz E-SCT 315M CD-D V-1-50Hz E-SCT 355T CD-D V-3-50Hz E-SCT 450T CDT-D V-3-50Hz E-SCT 500T CDT-D V-3-50Hz Heat recovery I DP25 F7 Control elements needed for managing the operation of the built-in resistances in the heat exchangers. uilt-in electric heater Supply Power (kw) Nº of stage ir ambient temperature control * The DD Pulser should be installed with the M Pulser when the power exceeds 3.6 kw. Supply air temperature control Controller in room Controller Controller within cabinet (Din-rail) djust. Duct sensor to limit Electric controller with Min/Max limiting sensor room sensor 0/30ºC Electric controller Duct sensor 0/30ºC supply air temperature 0/60ºC Optional External potentiometer on cabinet 0/30ºC CD-DI 05 Single phase 230V 2 1 PULSER PULSER M TG-R430 PULSER D TG-K330 TG-K360 TI-30 MCR-1 CD-DI 08 Single phase 230V 4 2 PULSER + P.DD* PULSER + P.DD* TG-R430 PULSER D + P.DD* TG-K330 TG-K360 TI-30 MCR-1 CD-DI 18 Single phase 230V 6 2 PULSER + P.DD* PULSER + P.DD* TG-R430 PULSER D + P.DD* TG-K330 TG-K360 TI-30 MCR-1 CD-DI 30 Three phase 400V TG-R430 TTC-25 TG-K330 TG-K360 TI-30 MCR-1 CDT-DI 45 Three phase 400V TG-R430 TTC-25 TG-K330 TG-K360 TI-30 MCR-1 CDT-DI 56 Three phase 400V TG-R430 TTC-25 TG-K330 TG-K360 TI-30 MCR-1 Timer Installation with external electric heater Supply Ø (mm) Power (kw) Electric heater type Electric heater Defrosting operation control (Heat exchanger protection) Duct sensor -20/10ºC External potentiometer -20/30ºC Electric heater Supply air temperature control Duct sensor 0/30ºC External potentiometer 0/30ºC CD-D 05 Single phase 230V 200 2,1 E-200/2M PULSER D TG-K310 TI-10 PULSER D TG-K330 TI-30 CD-D 08 Single phase 230V E-250/3M PULSER D TG-K310 TI-10 PULSER D TG-K330 TI-30 CD-D 18 Single phase 230V E-315/4M PULSER D + P.DD TG-K310 TI-10 PULSER D + P.DD TG-K330 TI-30 CD-D 30 Three phase 400V E-355/60T TTC-25 TG-K310 TI-10 TTC 25 TG-K330 TI-30 CDT-D 45 Three phase 400V E-400/90T TTC-25 TG-K310 TI-10 TTC 25 TG-K330 TI-30 CDT-D 56 Three phase 400V E-400/90T TTC-25 TG-K310 TI-10 TTC 25 TG-K330 TI-30

26 Electric heater batteries The heater battery operation must be enslaving to the fan operation. The installation must include a pressure switch to switch off the electric heater battery supplies in case of fan failure. E-SCT* Electric heating batteries with built-in electronic temperature control. E* Electric heater batteries Functions: - Defrosting operation. - Post heating operation. CD-D/DI/DC 05 CD-D/DI/DC 08 CD-D/DI/DC 18 CD-D/DI/DC 30 CDT-D/DI/DC 45 CDT-D/DI/DC 56 Electric heater batteries E-200/2M E-250/3M E-315/4M E-355/60T E-400/90T E-400/90T ccessories for air treatment -C* External coil module for hot water. External coil module CD-D/DI/DC 05 -C 05 CD-D/DI/DC 08 -C 08 CD-D/DI/DC 18 -C 18 CD-D/DI/DC 30 -C 30 CDT-D/DI/DC 45 -C 45 CDT-D/DI/DC 56 -C 56 -F* External coil module for cold water. External coil module CD-D/DI/DC 05 -F 05 CD-D/DI/DC 08 -F 08 CD-D/DI/DC 18 -F 18 CD-D/DI/DC 30 -F 30 CDT-D/DI/DC 45 -F 45 CDT-D/DI/DC 56 -F 56 HUMC* diabatic cooling module. CD-D/DI/DC 05 CD-D/DI/DC 08 CD-D/DI/DC 18 CD-D/DI/DC 30 CDT-D/DI/DC 45 CDT-D/DI/DC 56 * See complete information on the HET RECOVERY CCESSORIES. diabatic cooling module HUMC-05 HUMC-08 HUMC-18 HUMC-30 HUMC-45 HUMC-56

CAFIL. Heat recovery accessories. Heat recovery unit Accessories. Mounting accessories

CAFIL. Heat recovery accessories. Heat recovery unit Accessories. Mounting accessories Heat recovery accessories Mounting accessories CFIL Filtering boxes without a built-in filter and made from galvanised steel. To assemble FR-D/DI/DC-G4, FR-D/DI/DC- o FR-D/ DI/DC- filters. They incorporate

More information

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS Compact heat recovery unit with high efficiency counter-flow heat exchanger in 5 sizes from 580 m3/h to 3.650 m3/h. The casing is made from aluminium profile

More information

IN LINE MIXED FLOW DUCT FANS AND ELECTRIC HEATER TD-MIXVENT HEATING System

IN LINE MIXED FLOW DUCT FANS AND ELECTRIC HEATER TD-MIXVENT HEATING System HEATING System fan (from model 25) and a MBE electric heater installed on the discharge side of the fan. + MBE ELECTRIC HEATER MBE heater type - Insulated element rods. - Automatic overheat thermostat

More information

HRU SINGLE DWELLING HOUSES - BALANCED AIRFLOW WITH HEAT EXCHANGER AKOR ST HR Series

HRU SINGLE DWELLING HOUSES - BALANCED AIRFLOW WITH HEAT EXCHANGER AKOR ST HR Series AKOR ST HR Series AKOR ST HR Balanced-airflow for single dwelling houses, with crossflow heat exchanger. It guarantees continuous air replacement in single dwelling houses up to 92% of efficiency. It connects,

More information

The Sentinel Kinetic Horizontal Range

The Sentinel Kinetic Horizontal Range Lo-Carbon Sentinel Kinetic Horizontal Features & Benefits Manufactured in the UK Building Regulations DF compliant Recognised in SP PCDB Energy Savings Trust best practice compliant Up to 81% heat recovery

More information

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING Fresh air boxes ALB Comfortable climate with pre-heated, filtered supply air. Ingeniously practical: Supply air, heating and filter in a single unit. For direct in-duct mounting. The fresh air boxes ALB

More information

KITCHEN EXTRACTORS CK Series Plastic range CK-60 F CK-40 F CK-25 N

KITCHEN EXTRACTORS CK Series Plastic range CK-60 F CK-40 F CK-25 N KITCHEN EXTRACTORS CK Series Plastic range Centrifugal extractors manufactured from flame retardant plastic V. All extractors are class II insulation fitted with centrifugal impeller and single phase 23V-5Hz

More information

KITCHEN EXTRACTORS K Series

KITCHEN EXTRACTORS K Series KITCHEN EXTRACTORS K Series CK-4F CK-5 CK-6F Description Construction The K Series range of centrifugal extractors are specifically designed for the extraction of moist, grease laden air and fumes from

More information

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing Field of application Description Advantages Range Technical details Installation Remote controls Servicing Remote control ErP * ** Conpliance compliance. ErP ready. Advantages Reversible connections. Ventilation

More information

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit. Fresh air unit ALB ALB it s simple and so easy! Air supplied through a heater and filter in a single unit. The ALB fresh air units from Helios provide comfortable room temperatures. Fresh outside air is

More information

HRU SINGLE DWELLING HOUSES - ENERGY RECOVERY VENTILATION SYSTEMS WITH HEAT EXCHANGER AKOR BP HR Series

HRU SINGLE DWELLING HOUSES - ENERGY RECOVERY VENTILATION SYSTEMS WITH HEAT EXCHANGER AKOR BP HR Series AKOR BP HR Series AKOR BP HR Energy recovery ventilation systems for single dwelling houses or multi-dwelling blocks, with crossflow heat exchanger. It guarantees continuous air replacement in single dwelling

More information

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S Heat and Energy Recovery Ventilators 2018 AIR HANDLING UNITS 2 CONTENT KOMFORT EC S5B270(-E) 4 KOMFORT EC D5B1(-E) 8 KOMFORT EC S(B)(-E) 12 AIR HANDLING UNITS

More information

ACCESSOIRES ELECTRICAL ACCESSORIES

ACCESSOIRES ELECTRICAL ACCESSORIES Speed Controllers REB-1N and REB 2,5N Electronic single-phase speed controllers: Available in Wall Box or Flush Mount versions. Minimum speed adjustment. Single ON/OFF and speed regulation control knob.

More information

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 % Single-room heat recovery unit Air flow up to 59 CFM Heat recovery efficiency up to 96 % 2018 SINGLE-ROOM HEAT RECOVERY UNITS Features Efficient solution for supply and exhaust ventilation of enclosed

More information

KOMFORT EC DB Suspended heat recovery air handling units

KOMFORT EC DB Suspended heat recovery air handling units 2018 AIR HANDLING UNITS KOMFORT EC DB Suspended heat recovery air handling units Features Air handling units for efficient supply and exhaust ventilation in flats, houses, cottages and other buildings.

More information

Small Room Heat Recovery Ventilation

Small Room Heat Recovery Ventilation Small Room Heat Recovery Ventilation Ideal for smaller spaces that would benefit from heat recovery, such as staff rooms or offices Version 3.1 2 Breathing Buildings Small Room Heat Recovery 3 Small Room

More information

HEAT RECOVERY VENTILATION UNIT DESCRIPTION. FANS s Plug fans. s Direct drive continuous current motors with electronic switching

HEAT RECOVERY VENTILATION UNIT DESCRIPTION. FANS s Plug fans. s Direct drive continuous current motors with electronic switching HEAT RECOVERY VENTILATION UNIT DESCRIPTION APPLICATION s range is a PLUG&PLAY and a self-regulating Heat Recovery Ventilation unit with multilingual communication, for office and industrial applications.

More information

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK SUPPLY AND EXTRACT AIR UNIT WITH HEAT EXCHANGER AND HEAT RECOVERY, SECONDARY AIR OPTION, FOR

More information

Roof top SPACE RPC 450Z R407C M011

Roof top SPACE RPC 450Z R407C M011 Roof top SPACE RPC 450Z R407C M011 Page : 1 / 5 Independant roof mounted unit, cooling only, ready to be installed, designed for air conditioning of large volumes for industrial or commercial use. As per

More information

Cassette units Model Comfort Circle. - heating - cooling - ventilation

Cassette units Model Comfort Circle. - heating - cooling - ventilation Cassette units Model Comfort Circle - heating - cooling - ventilation Cassette unit: Comfort Circle A comfortable room and climate are pleasant to work in and may also entice visitors to lengthen their

More information

Lo-Carbon Sentinel Kinetic Horizontal

Lo-Carbon Sentinel Kinetic Horizontal Lo-Carbon Sentinel Kinetic Horizontal MVHR Unit Features & Benefits Manufactured in the UK Building Regulations ADF compliant Recognised in SAP Appendix Q Energy Savings Trust best practice compliant Up

More information

DAVE Supply (DS) Fans For Internal & External Use Installation and Maintenance

DAVE Supply (DS) Fans For Internal & External Use Installation and Maintenance 1.0 INTRODUCTION DVE Supply Fans For Internal & External Use Installation and Maintenance The Dave range of in-line backward curve fans consists of 9 sizes with a maximum duty of 1.1m3/s (1100l/s). Units

More information

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:

More information

66 on. Central ventilation system ZLS-DV EC according to DIN Central ventilation system ZLS EXTRACT AIR FIRE PROTECTION OUTSIDE AIR

66 on. Central ventilation system ZLS-DV EC according to DIN Central ventilation system ZLS EXTRACT AIR FIRE PROTECTION OUTSIDE AIR Central ventilation system ZLS Central ventilation system ZLS-DV EC according. ZLS-DV EC is the ideal central ventilation system in multi-storey construction according. EXTRACT AIR OUTSIDE AIR FIRE PROTECTION

More information

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT Made in Italy Air Conditioning High Wall Fan Coil -ECM QUALITY MANAGEMENT SYSTEMS ISO 9001 - Cert. n 0545/5 www.eurovent-certification.com www.certiflash.com ENVIRONMENTAL COMFORT CONTENTS Introduction

More information

N M AirControl AHU. Control manual

N M AirControl AHU. Control manual N 10.63 M 03-2016 AirControl AHU Control manual EN CONTENTS PAGE 1 - MONITORING AND CONTROL 2 1.1 The program 2 1.2 The HMI terminal 2 1.3 The controller 4 1.4 Description of the air handling units 4

More information

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating. capacity: Heating capacity: 20,8 to 135,1 kw 22,6 to 144,7 kw Scroll compressors R-410A refrigerant Confi guration fl exibility Silent operation DESCRIPTION The AirDuo cooling units and are units which

More information

ENG. IDEO 325 Ecowatt. Installation Manual

ENG. IDEO 325 Ecowatt. Installation Manual ENG IDEO 325 Ecowatt Installation Manual Before manipulating this device, disconnect the electricity supply. During normal operation, never stop the ventilation system. General Information High-performance

More information

K Series CK-25 N CK-35 N CK-40 F CK-50 CK-60 F ECO-500 KITCHEN EXTRACTORS. Kitchen extractors CK

K Series CK-25 N CK-35 N CK-40 F CK-50 CK-60 F ECO-500 KITCHEN EXTRACTORS. Kitchen extractors CK KITCHEN EXTRACTORS K Series CK-25 N CK-35 N CK-6 F Range of centrifugal extractors specifically designed for the extraction of moist, grease laden air and fume from under domestic cooker canopies. This

More information

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors -15 C +63 C E.V.I. The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems or

More information

OnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment!

OnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment! OnePlus Packaged Air Handling Units for Ducted Installations Caring for the environment! A New Concept New packaged air handling units OnePlus series are the latest offspring of Apen Group s experience.

More information

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range PRODUCT SELECTION DATA Plug & play unit (built-in control) Class A+ across entire range Classic/Vertical/ceiling-mounted dualflow units High-efficiency heat recovery unit High performance plug fan High-efficiency

More information

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h PRODUCT DATA COMFORT 5000 BY NILAN Ventilation & passive heat recovery Commercial Passive heat recovery Ventilation < 5300 m 3 /h COMFORT 5000 The Comfort 5000 is a ventilation unit suitable for central

More information

SILVERTOP RANGE ENERGY RECOVERY

SILVERTOP RANGE ENERGY RECOVERY ENERGY RECOVERY RANGE Self-regulating and high efficiency (>9%) Heat Recovery Ventilation Compact Unit with high performance. Econological solution. Airflow from 1 to 5 5 m3/h 3 3 CALADAIR I 61 rue de

More information

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams Integrated chilled beams Key figures Connections: 1x mm, 2x mm Airflow: 5-60 l/s Pressure range: 40 - Pa Size: 293 x 200 mm (WxH) Length: 1192 or 1792 mm Total effect: up to 1200W Cumulus is available

More information

Controlled mechanical ventilation GB 03

Controlled mechanical ventilation GB 03 RECUPER SLIM 2018 Controlled mechanical ventilation GB 03 ir conditioning Systems to install Recover... your wellbeing The home is a precious asset where we all spend a major time of your life. So it s

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION VALLOX-product code: HVAC code: 358500 L 35850 R 79076 L 79077 R SOUND ATTENUATOR (OPTIONAL) IVALLOX 252 WATER OPERATED POST- HEATING UNIT (OPTIONAL) ELECTRICAL POST-HEATING UNIT (OPTIONAL) ELECTRICAL

More information

CYLINDRICAL CASED AXIAL FLOW FANS. Cylindrical cased axial flow fans TCBB. Corrosion resistance. Impeller dynamically balanced.

CYLINDRICAL CASED AXIAL FLOW FANS. Cylindrical cased axial flow fans TCBB. Corrosion resistance. Impeller dynamically balanced. CYLINDRICAL CASED AXIAL FLOW FANS COMPACT Series TCBB (aluminium impellers) Range of cylindrical cased axial fans fitted with aluminium impellers and manufactured from high grade rolled galvanised steel

More information

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT - WHOLE HOUSE HEAT RECOVERY UNIT 95% efficient, SAP Appendix Q compliant heat recovery unit.. 29 285 82 BENEFITS High efficiency 95% efficient, with DC motors using 5% less energy than traditional fans.

More information

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 % FRESHBOX 100 Single-room heat recovery unit Air capacity up to 100 m³/h Heat recovery efficiency up to 96 % FRESHBOX 100 CONTENTS FRESHBOX 100 FEATURES 3 DESIGN 4 OPERATING PRINCIPLE 6 CONTROL 6 APPLICATION

More information

RS /E-EV C01 SERIES

RS /E-EV C01 SERIES The well-known RS 300-800/E-EV Burner Series, till now available up to 8 MW, has been upgraded with two new powerful burner models, the RS 1000-1200/E-EV models that extend his max output up to 12 MW and

More information

LOW NOx MODULATING GAS BURNERS

LOW NOx MODULATING GAS BURNERS RS/E - RS/EV BLU SERIES LOW NOx MODULATING GAS BURNERS RS/E - RS/EV BLU SERIES RS 300/E BLU 500/1350 3800 kw RS 400/E BLU 800/1800 4500 kw RS 300/EV BLU 500/1350 3800 kw RS 400/EV BLU 800/1800 4500 kw

More information

VERSO Air Handling Units

VERSO Air Handling Units Energy efficient solutions for profitable indoor climate VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P air handling units equipped with recuperation system

More information

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models. AIR HANDLING UNITS WITH HEAT RECOVERY Series Series VUT 350 PE EC VUT 600 PE EC VUT 1000 PE EC VUT 2000 PE EC VUT 3000 PE EC VUT 600 PW EC VUT 1000 PW EC VUT 2000 PW EC VUT 3000 PW EC Ceiling mounted air

More information

Air heater/cooler in combination with ground source heat pump

Air heater/cooler in combination with ground source heat pump Swegon CASA Air heater/cooler in combination with ground source heat pump Installation, operation and maintenance instructions for design engineers, installation engineers and service personnel SDHWM_c_EN

More information

pyxis hp "u" pyxis hp "u" IDEA NEW rcgroupairconditioning

pyxis hp u pyxis hp u IDEA NEW rcgroupairconditioning Comfort PYXIS HP U : ir / water reversible heat pumps for outdoor installation, equipped with scroll compressors and axial fans Cooling Capacity: 42,3 195,0 Heating Capacity: 47,1 222,0 NEW IDE R410 rcgroupairconditioning

More information

RS /E-EV C01 SERIES

RS /E-EV C01 SERIES The well-known RS 300-800/E-EV BLU Burner Series, till now available up to 8 MW, has been upgraded with two new powerful burner models, the RS 1000-1200/E-EV C01 models that extend his max output up to

More information

QZHW Fan Coil Unit. Key features. Specifications

QZHW Fan Coil Unit. Key features. Specifications Key features High wall installation Cooling ( pipes) Low noise level Electrical heating coil ECM version for low energy consumption QZHW is a high wall fan coil unit available in sizes and many different

More information

REB-1N / REB-1NE / REB-2,5N / REB-2,5NE

REB-1N / REB-1NE / REB-2,5N / REB-2,5NE Single phase speed controller REB-1N / REB-1NE / REB-2,5N / REB-2,5NE Electronic single phase speed controllers. Available in wall box or flush mount versions. Fuse protected + spare fuse included. Minimum

More information

NEXT DL NEXT DL. rcgroupairconditioning

NEXT DL NEXT DL. rcgroupairconditioning NEXT DL: Close control air conditioners with displacement air delivery with remote condenser, or built in water cooled condenser or for chilled water feeding Cooling capacity: 7,7 51,4 NEXT DL rcgroupairconditioning

More information

Roof top SPACE RPC 315Z R407C MA00

Roof top SPACE RPC 315Z R407C MA00 Client : TIHE SERV Contact : Romeo Staicu Your reference : Your contact : Phone : E-mail : Page : 1 / 6 Roof top SPACE RPC 315Z R407C MA00 Independant roof mounted unit, cooling only, ready to be installed,

More information

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction Air Comfort Air Treatment Energy Recovery eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction eco PREMIUM - Technical Instruction REDA 2 Contents Description Applications... 3 Quality & environment...

More information

High wall fan coils Climmy FHW/FHW-ECM. Technical Catalogue

High wall fan coils Climmy FHW/FHW-ECM. Technical Catalogue High wall fan coils Climmy FHW/FHW-ECM Technical Catalogue Versions and Main components MODELS WITHOUT ELECTRIC HEATER All versions are available without valves, with 2 way valve or with 3 way valve fitted

More information

Personalized comfort for offices and shopping malls RANGE OPERATING LIMITS

Personalized comfort for offices and shopping malls RANGE OPERATING LIMITS R-c Personalized comfort for offices and shopping malls iscreet solution in centralized facilities with closed water loop asy installation in false ceiling T-XH-5-I-I SRIPTION Heat Pumps and ooling Units

More information

MRXBOXAB-ECO3 MRXBOX-ECO3

MRXBOXAB-ECO3 MRXBOX-ECO3 NUAIRE MVHR MRXBOX-ECO3 and Opposite Handed versions ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due

More information

MRXBOXAB-ECO2 MRXBOX-ECO2

MRXBOXAB-ECO2 MRXBOX-ECO2 NUAIRE MVHR MRXBOX-ECO2 and Opposite Handed versions ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due

More information

InspirAIR Home RESIDENTIAL AIR PURIFICATION

InspirAIR Home RESIDENTIAL AIR PURIFICATION InspirAIR Home InspirAIR Home The fi rst Aldes connected solution for centralised air purifi cation which beats to the rhythm of your life. RESIDENTIAL AIR PURIFICATION CONTENTS Presentation........................................................

More information

unico pf unico pf rcgroupairconditioning

unico pf unico pf rcgroupairconditioning : ckaged air cooled liquid chillers for indoor installation, equipped with scroll compressors and plug fan Cooling Capacity: 19,6 264 unico pf PLTE rcgroupairconditioning R410 E C MIN FETURES ir cooled

More information

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units CI/SfB (57.7) 1st Edition Vent-Axia MVHR Units Vent-Axia Sentinel Kinetic Horizontal Range Lo-Carbon Sentinel Kinetic Horizontal MVHR Units Features & Benefits Manufactured in the UK Building Regulations

More information

next evo cw next evo cw rcgroupairconditioning

next evo cw next evo cw rcgroupairconditioning : Close control air conditioners for chilled water feeding with upflow or downflow air delivery Cooling Capacity: 6,2 248,0 rcgroupairconditioning E C CHILLED WTER UP FLOW DOWN FLOW MIN FETURES Chilled

More information

Outside Air Requirements... SOLVED!

Outside Air Requirements... SOLVED! Outside Air Requirements... SOLVED! Advancing VentilationTM refresh-0918 September 2018 The Whole Building Ventilation Standard With houses and buildings being built as tightly as possible, we are plagued

More information

ATC Heating Devices. P. 1 ATC Heating Devices

ATC Heating Devices. P. 1 ATC Heating Devices ATC Heating Devices P. 1 ATC Heating Devices ATC Heating Devices Suspended water heater FWW The hot water heater is attached to a wall using brackets. The direction of air flow (upwards or downwards) is

More information

MODEL TRC TOTAL RECOVERY FOR ALL CLIMATES - COMMERCIAL APPLICATIONS

MODEL TRC TOTAL RECOVERY FOR ALL CLIMATES - COMMERCIAL APPLICATIONS TOTAL RECOVERY FOR ALL CLIMATES - COMMERCIAL APPLICATIONS MODEL FTURES MERV-8 filters Transformer/relay package allowing simple on/off control Access doors for easy access to blowers, core and filters

More information

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models. AIR HANDLING UNITS WITH HEAT RECOVERY Series Series VUT 350 PE EC VUT 600 PE EC VUT 1000 PE EC VUT 2000 PE EC VUT 3000 PE EC VUT 600 PW EC VUT 1000 PW EC VUT 2000 PW EC VUT 3000 PW EC Ceiling mounted air

More information

BATHROOM EXTRACT FANS SILENT-100 Series

BATHROOM EXTRACT FANS SILENT-100 Series SILENT-1 Series Range of axial extractors with airflow rates of 95 m 3 /h, for connection to 1 mm diameter circular ducting. Motor mounted on silent-elastic-blocks which absorb the vibrations and allow

More information

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue cert. n. 0545 Product is subject to and complies with Regulation (UE) N.327/2011 Fan Coil Unit Cassette SkyStar Jumbo ECM technical catalogue SkyStar Jumbo ECM Table of contents SkyStar Jumbo ECM TABLE

More information

kw. Flexair. General description. Main components. CLIMATIC controller. Air cooled rooftop packaged unit

kw. Flexair. General description. Main components. CLIMATIC controller. Air cooled rooftop packaged unit Flexair ir cooled rooftop packaged unit 85 0 kw Main applications Large and light commercial buildings inemas, theatres Industrial buildings and logistic centers Why this choice? Energy efficient solution

More information

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB T_SMT_0609_GB 4,9 49,5 kw Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans INDEX SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3 CE CONFORMITY... 3 WORKING

More information

pyxis u pyxis ua NEW rcgroupairconditioning

pyxis u pyxis ua NEW rcgroupairconditioning Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 44,9 200,0 rcgroupairconditioning R410 C PLTE

More information

Domestic fans. Circular duct fans 1. Rectangular duct fans 2. Roof fans 3. Axial fans 4. Smoke evacuation fans 5.

Domestic fans. Circular duct fans 1. Rectangular duct fans 2. Roof fans 3. Axial fans 4. Smoke evacuation fans 5. Domestic fans Circular duct fans Rectangular duct fans Roof fans xial fans Smoke evacuation fans TEX rated fans Corrosion resistant fans Domestic fans ccessories Wiring diagrams 0 Index Content Centrifugal

More information

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation NUAIRE MVHR and Opposite Handed version ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due to its intelligent

More information

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE NEW ECO RANGE MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) Mechanical Ventilation with Heat Recovery Proud to Build British u Nuaire is a world leader in the design and manufacture of fans and ventilation

More information

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery. PRODUCT DATA COMBI 300 POLAR BY NILAN Ventilation with passive & active heat recovery Domestic Passive heat recovery Active heat recovery Ventilation < 350 m 3 /h Comfort heating Comfort cooling COMBI

More information

Domestic & Commercial Fans

Domestic & Commercial Fans Max. airflow l/s Axial Fan Centrifugal Fan Speed Controllable Reversible Airflow Page Number BF IF CF CBF BF 64 * 16 IF 64 * 16 EAF LV 23 * 169 ECF LV 31 * 169 CF 25 * 170 CBF 31 * 170 RVF 0 * * 171 BRAVO

More information

E U R O V E N T CERTIFIED PERFORMANCE

E U R O V E N T CERTIFIED PERFORMANCE Compact Horizontal Air-Air Heat Pump Model RTH-7K to 3K Ref.: Y-R719 7 Technical information E U R O V E N T CERTIFIED PERFORMANCE I S O 9 1 ER-8/1991 Clima Roca York S.L. is participating in the EUROVENT

More information

Chiller units and air-water heat pumps RANGE OPERATING LIMITS

Chiller units and air-water heat pumps RANGE OPERATING LIMITS Chiller units and air-water heat pumps Cooling capacity: Heating capacity: 6, to 6,6 kw 8, to 69,4 kw ENVIRONMENTALLY FRIENDLY HFC R407C PROTECTION DE L'ENVIRONNEMENT Silent and compact design Air-conditioning

More information

KSDR ECOWATT. ErP AHU SIMPLE FLOW. AHU simple flow COMPACT - CENTRIFUGAL - ECM < 20,000 M3/H

KSDR ECOWATT. ErP AHU SIMPLE FLOW. AHU simple flow COMPACT - CENTRIFUGAL - ECM < 20,000 M3/H TETIAY BUILDINGS COMPACT - CENTIFUGAL - ECM < 2, M3/H NEW INDUSTIAL AND LOGISTICAL BUILDINGS BUILDINGS FO ESTAUATION EI 88 EXG Modbus and BACnet control communication Coils fitted within the AHU Backward

More information

FREETIME RANGE ENERGY RECUPERATION

FREETIME RANGE ENERGY RECUPERATION ENERGY RECUPERTION RNGE Self-regulating dual flow air handling unit with rotating heat exchanger, very high efficiency (>8%), high recovery efficiency, compact. Econologic solution Flow rate 1 to 3,5 m

More information

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions) NUAIRE MVHR (including opposite handed versions) ACHIEVES 100% DUTY IN BYPASS MODE and MRXBOXAB- ECO-LP1-OH are specically designed for apartment applications where space is a premium. The new MRXBOX95-LP1

More information

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter VALLOX Product Code: 3158400 L 3158410 R SILENCER (OPTIONAL) INSTRUCTIONS FOR USE AND MAINTENANCE WATER CIRCULATED POST-HEATING UNIT (OPTIONAL) ELECTRIC POST-HEATING UNIT (OPTIONAL)) PREHEATER (OPTIONAL)

More information

VERSO Air Handling Units

VERSO Air Handling Units VERSO Air Handling Units Energy efficient solutions for profitable indoor climate VERSO Air Handling Units VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P

More information

Refrigerant R407C CW-AR. 2.4 to 3.1kW. Water Source Heat Pumps - Vertical Mounting Version Models 07 to to 2.7kW

Refrigerant R407C CW-AR. 2.4 to 3.1kW. Water Source Heat Pumps - Vertical Mounting Version Models 07 to to 2.7kW Refrigerant R407C CW-AR Water Source Heat Pumps - Vertical Mounting Version Models 07 to 12 2.4 to 3.1kW 1.9 to 2.7kW Some advantages... RAL 9010 painted cabinet 3-fan speeds G2 filter is supplied as

More information

Heat Recovery Unit HERU. web-version

Heat Recovery Unit HERU. web-version Heat Recovery Unit HERU web-version HERU 50 and 75 Heat recovery unit HERU is designed to suit places like houses, offices and other buildings where there is a big demand for high temperature efficiency,

More information

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique

More information

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED EQV R-407C WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED Size Cooling Heating [kw] [kw] 5 1,9 2,2 7 2,4 2,5 9 2,6 2,5 15 3,3 3,2 17 3,7 3,7 REPLACE: BT02E008GB-01 The Versatemp EQV units

More information

PRODUCT RANGE: ROOFTOP PACKAGE

PRODUCT RANGE: ROOFTOP PACKAGE Packaged Air Cooled Reverse Cycle Type Air Conditioner Range 11-125kWr With Energy / Heat Recovery The Roof Top Packaged unit range is designed to be used when high fresh air quantities are required. They

More information

... RTU. Packaged Air to Air Heat Pump...

... RTU. Packaged Air to Air Heat Pump... ... RU Packaged ir to ir Heat Pump... RU... Packaged ir to ir Heat Pump... Reznor's RU range is composed of air to air heat pumps in packaged rooftop configurations, with various heat recovery options

More information

PYXIS U PYXIS U. rcgroupairconditioning

PYXIS U PYXIS U. rcgroupairconditioning Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 44 284 rcgroupairconditioning MIN FETURES

More information

NEW. MB control board. communication protocol. for Modbus. Air Conditioning Carisma CRSO High Pressure Fan Coil Units

NEW. MB control board. communication protocol. for Modbus. Air Conditioning Carisma CRSO High Pressure Fan Coil Units NEW MB control board for Modbus communication protocol Compliant with ERP 0 Regulation (EU) No. 7/0 Quality management systems ISO 900 Cert. n 0/ www.eurovent-certification.com www.certiflash.com Air Conditioning

More information

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h PRODUCT DATA COMFORT 00 BY NILAN Ventilation & passive heat recovery Commercial Passive heat recovery Ventilation < 00 m /h COMFORT 00 The Comfort 00 is a ventilation unit suitable for central ventilation

More information

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply. Halton CSW Swirl comfort unit for ceiling installation The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply. A combined cooling, heating, and supply-air unit for flush

More information

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions Dehumidifiers for radiant cooling systems with heat recovery 50 The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area

More information

Laboratory refrigerators and freezers

Laboratory refrigerators and freezers Laboratory refrigerators and freezers laboratory refrigerators (+1 / +8 ºC) laboratory freezers (-18 / -22 ºC) plasma freezers (-30 / -35ºC) blood bank refrigerators (+4 ºC) combination fridge / freezer

More information

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK GENERAL Climate Wizard coolers operate with a high ratio of energy efficiency and deliver cool fresh air at extremely low energy cost. The CW-80T-TWIN is characterized by having no additional moisture

More information

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25 Residential Heat Recovery Ventilation REHVA European Guidebook No 25 REHVA European Guidebook No 25 2 Limited to mechanical supply and exhaust ventilation Targeted to engineers, HVAC consultants and contractors

More information

TopVent Design Handbook

TopVent Design Handbook TopVent Design Handbook Recirculation Units and Supply Air Units for Heating and Cooling High Spaces TopVent Content TopVent DHV Recirculation unit for heating high spaces TopVent NHV Recirculation unit

More information

BRISE. Heating and cooling from a single radiator

BRISE. Heating and cooling from a single radiator BRISE Heating and cooling from a single radiator T: + (0)5 6 5 F: + (0)5 6 5 jaga@jaga.co.uk Brise Wall-Mounted Dimensions Product code: BRIW Product code: BRBW B D C F 00 E 55 68 7 0 0 80 Ø 0 70 G 98

More information

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h PRODUCT DATA COMFORT 40 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 40 m /h COMFORT 40 Product description The Comfort 40 is an energy-efficient ventilation

More information

Specification data Topvex. Rotating or Cross flow heat exchanger.

Specification data Topvex. Rotating or Cross flow heat exchanger. Specification data Topvex Rotating or ross flow heat exchanger www.systemair.com Topvex Topvex SR, TR, SX and TX is a series of efficient ventilation units designed for offices, shops, schools, daycare

More information

Air Comfort. Installation instructions (English) A

Air Comfort. Installation instructions (English) A Air Comfort Installation instructions (English) WWW.BRINKAIRFORLIFE.NL 614788-A This appliance may be used by children as of 8 years of age, persons of reduced mental or physical capacities and those of

More information