Specification data Topvex. Rotating or Cross flow heat exchanger.
|
|
- Dennis Clarke
- 5 years ago
- Views:
Transcription
1 Specification data Topvex Rotating or ross flow heat exchanger
2 Topvex Topvex SR, TR, SX and TX is a series of efficient ventilation units designed for offices, shops, schools, daycare centres or similar premises. The units are especially designed to meet the coming energy requirements and have therefore a very low energy use. To simplify the installation and commissioning the units are included with control system and pre-configured. fan motors low energy use and low noise Unlike motors with frequency converters, the motors operate with high efficiency even at low RPM (see the diagram). This contributes to good energy saving performance. The motors are also very quiet at both high and low RPM. rives High efficiency even at reduced speed asy inspection To facilitate inspection and maintenance, both fans and the rotating/crossflow heat exchanger are removable. SR07, 09 and 11 have a fi xed heat excanger. ll power cables have quick release couplings the fans and heat exchanger can be released easily. It could not be easier! Topvex are delivered pre-programmed, tested and ready for installation. onnect the Topvex unit to the duct system, connect any external components, connect the main supply, set the time and date, adjust the week scheduler, temperatures, airflows and the unit is installed. It could not be easier! fficiency (%) Speed (min -1 ) 2
3 asy electrical connections and service ll electrical connections are done at the same terminal block, with clear markings. General Topvex units are delivered enclosed in plastic and mounted on pallets. The units are fully connected internally. The automatic control system is preset and has been test-run at the factory. ny cables to external components should be connected to terminals in the connection space. The same applies to valve actuators for heating coils. Measurement at Systemair's evelopment entre Topvex are measured and tested at Systemair's evelopment entre. The air volume is measured in accordance with M Laboratory methods of testing fans for rating. Sound is measured in accordance with M Test ode for Sound Rating. Topvex TX06 L Unit housing The unit's casing is made up from double-skinned 1.0 mm aluzinc sheet metal, Z 185, with 50 mm of internal insulation. To avoid sharp edges bevelled corners from cast aluminium are used. Topvex stands on fi xed sections that raise the units about mm above the floor. Topvex has large front doors that have lockable handles and removable hinges. separate safety switch is included. The control panel is connected with 10 m cable (included). Topvex TR09-15 L Topvex SR04-06 L 3
4 e-icing function TX/SX Ice accretion of the heat exchanger is depending on the outdoor temperature and the humidity in the extract air. The humidity in the extract air is varying a lot depending on the activities in the building e.g. an industry premises is normally producing much less humidity than a day-care centre. Therefore has the aggressiveness of the de-icing function been made settable (1-5) so that it can be optimized to different applications. Topvex SX06 L omponents ans Topvex has effective plug-fans with maintenance-free external rotormotors. The fans have been selected to provide optimal operation in respect of air volume, sound level and efficiency. The units have electronically commutated motors, so called -motors with very high efficiency. The motors are controlled in steps via the control unit. To facilitate maintenance and servicing the fans have quick release connections for the electrical cables. Heat exchanger Rotating The rotating heat exchanger is nonhygroscopic and belt driven. spare belt is mounted on the rotor wheel on delivery. The rotor belt is a round plastic belt of the elastic type with high friction. rotor guard will give an alarm if the rotating heat exchanger stops. The rotor construction with pleated aluminium is optimised in respect of high efficiency and low pressure drop. The rotor have a robust construction witch makes it stable and reliable also after a very long time of operating. t balanced airflows the efficiency is up to 85%. The heat exchanger is removable with quick release connections for the power cables. Heat exchanger rossflow The crossflow heat exchanger is non-hygroscopic. The construction with pleated aluminium is optimised in respect of high efficiency and low pressure drop. t balanced airflow the efficiency is up to 60%. The heat exchanger is removable with quick release connections for the power cables. y-pass damper Topvex TX/SX is equipped with a stepless by-pass damper as standard. The damper is used to by-pass the supply air during warm season(no need of heat recovering) and to de-ice the heat exchanger during cold season (selectable). Heating coil water The hot water coil is located after the supply air fan. The coil is mounted for easy connection of the water pipes through out the gable of the unit. The material is copper piping with a frame of galvanised sheet steel and aluminium fins. The coil has venting nipples and an immersion sensor as frost guard. If there is a risk of freezing in the hot water coil, the control valve is forced open to prevent freezing. If there is still a risk of freezing, the unit is stopped and the outdoor air damper (accessory) is closed. fter a freezing situation, the unit will re-start when the return water temperature is above 7 and the alarm has been acknowledged. The hot water coils are available in: Low power HWL (all Topvex) High power HWH (Topvex TR/TX/ SR/SX 03-06). Heating coil electric The heating coil is located after the supply air fan. It has elements of stainless steel. The electric heating coil has two overheating protection one with automatic reset and one with manual reset. When the unit is switched off, through the overheating protections, the built-in clock or the hand/auto switch, the electrical heater is immediately stopped while the fans are kept running during 3 minutes for cooling down the heater. fter an overheating situation, the unit will re-start when the overheating protection has been reset and the alarm has been acknowledged. 4
5 ilters The units are delivered with bag fi lters as standard. oth of the fi lters are placed before the heat exchanger, to keep the exchanger clean. The fi lters are mounted in guide rails that facilitate insertion and removal for inspection and service. The guide rails are spring mounted and fitted with sealing strips to provide optimal sealing against the fi lters. ilter class 7 on supply air and 5 on extract air are used as standard. ilter monitoring is done via the built-in timer (Standard controller) or via built in pressure transmitters measuring the fi lter pressure drop (dvanced controller). 5 7 uct connection ircular connections with rubber sealing, rectangular have flanged connections. Topvex Rectangular ircular TR03 ø250 TR04 ø315 TR06 250x500 TR09 300x700 TR12 350x800 TR15 350x1000 SR03 ø315 SR04 500x250 SR06 600x300 SR07 600x300 SR09 600x400 SR11 800x400 TX03 ø250 TX04 ø315 TX06 300x500 SX03 ø315 SX04 500x250 SX06 600x300 Optional heat exchangers/connections TR 03, 04, 06, 09, 12, 15 SR 03, 04, 06, 07, 09, 11 TX 03, 04, 06 SX 03, 04, 06 5
6 Overview onnections & heat exchangers lue margin = Top connection Green margin = Side connection = Rotating heat exchanger = ross flow heat exchanger imensions Top connection Width Height epth ivisible TR TR TR TR /2= 895 TR /2= 965 TR /2= 965 TX TX TX Side onnection Width Height epth ivisible SR SR SR SR /2-29= 890 SR /2-29= 890 SR /2-29= 890 SX SX SX Min/max airflow TX 03 TR 03 TX 04 TX 06 TR 04 TR 06 TR 09 TR 12 TR 15 0,0 0,2 0,4 0,6 0,8 1,0 1,2 1,4 1,6 1,8 2,0 m 3 /s m 3 /h SX 03 SR 03 SX 04 SX 06 SR 04 SR 06 SR 07 SR 09 SR 11 0,0 0,2 0,4 0,6 0,8 1,0 1,2 1,4 1,6 1,8 2,0 m 3 /s m 3 /h 6
7 isplay The illuminated display has 4 rows of 20 characters each and 20 different languages are available. rrows are used to simplify the usage. The background illumination is normally switched off, and is activated by pushing one of the buttons. The illumination is then switched off again after a period of inactivity. Ls The alarm L is marked with a symbol. The write enable L is marked with a symbol. Push-uttons ll functions can be set (configured) by using the information in the display and the push-buttons on the controller. Standard & dvanced control Systemair are using two different controls depending on ir Handling Unit. To facilitate the use of the controllers both controllers have the same menu structure and using the same technical terms. or further information, see page Standard, 17S TR03-06 TX03-06 SR03-06 SX03-06 dvanced, 28 TR09-15 SR07-11 ontrols Standard is a controller designed to be easy to handle. This controller is used in the smaller ompact HU's, up to approx m 3 /h. dvanced is a fully equipped controller designed to cover the most of the market needs. dvanced is used in the larger ompact HU's, m 3 /h. SP control panel Width = 115 mm Height = 94 mm epth = 26 mm Main difference between Standard and dvanced control: Standard, 17S dvanced, 28 Using of -tool, a P-based No Yes commissioning software. Temperature control 3 control modes 6 control modes Time controlled airflow Week timer Week timer + Holidays + igital timer channels for e.g. door locks an control Settable between 0-100% control signal. V, constant air volume or VV, variable air volume. Outdoor temp. dependent airflow. Heat exchanger control Rotating, on/off. Rotating, step-less. emand control X cooling control, (xternal X cooler) Possible to use external equipment with relay output for increasing airflow one step. Step controller for converting the analogue controls signal to a digital 2-step, binary control necessary (accessory). Possible to use external equipment with analogue output for step-less increasing of air flow or relay output. Up to 3-step, binary control is standard. HW/W Pump control No Yes ilter supervising Time controlled Pressure drop controlled 7
8 Regulations S=standard settings P=possible settings =choose when ordering O=option SR03, 04, 06 SX03, 04, 06 SR07, 09, 11 TR03, 04, 06 TX03, 04, 06 TR09, 12, 15 ontroller Standard, 17S Standard, 17S dvanced, 28 ontrol Panel Remote with 10 meter cable S S S Repeater When more than 10 meter between unit and control panel O O O ommissioning software tool O Temperature control xtract air P P S air S S P Outdoor temperature compensated air P P P ascaded Room control P Outdoor temp. dependent switching between /xtract air or /Room control P ir flow control Week timer, two separate running periods S S S an control Individual stepless voltage control S S ir flow control, V Pressure control, VV Outdoor compensated air flow S Heat exchanger ross flow S y pass damper, stepless S Rotating, on/off S Rotating, stepless S Heater Hotwater lectrical ooler old water coil V output signal P P P X cooling. 24V (1, 2 or 3-stage binary) output. * P * P P ree cooling Wall mounted outdoor sensor and room temp. sensor necessary P ool recovering P P P emand ventilation, O 2 2-step, O 2 sensor with a potential free switch. P P Stepless, O 2 sensor with V output signal. P Pump control Heating, 24V output signal P ooling, 24V output signal P xchanger efficiancy uct mounted exhaust temp. sensor necessary. P xtended running S S S Week schedule hanging between Normal run, Reduced run or Off. S S S amper control Outdoor/xhaust air S S S larm larm messages S S S High and low priority S Sum alarm, 24V output signal S S S ilter alarm on time (month) S S ilter alarm on pressure difference (Pa) S ommunication xoline, Modbus via RS 485 S S S LON, xoline via TP/IP O O * Step controller S2/ is necessary. onverts V signal to relay output. 8
9 Notes 9
10 Topvex TR Topvex TX TX06 TR09-15 TX03-04 TR06 TR03-04 T Top connection R Rotating heat exchanger X ross flow heat exchanger Topvex TR/TX is a Plug and play air handling unit with a modern design intended for ventilating offices, day-care centres or used as zone ventilation in larger buildings e.g. schools. Top-connection of the air-ducts minimise the ootprint of the unit. To meet the new restricted energy requirements with low SP (Specific an Power) Topvex is equipped with fan motors. -motors consume an average of 30% less energy than motors. In some applications, the saving can be 50% or more. Topvex TR is equipped with a high efficiency rotating heat exchanger with an efficiency of up to 85%. Rotating heat exchangers do not need condense water drainage and is therefore very flexible to install. Topvex TX with its crossflow heat exchanger is normally used where it is a requirement that the supply and exhaust air must be kept separated. The units have an efficient deicing function. Topvex TR/TX units have energy saving functions like: - Week schedule. - ool recovering to recover the chilliness in the extract air during warm season. If using an external cooling unit. - emand controlled airflow by using a O 2 /humidity sensor, movement detector etc. - Sum alarm output for central supervision of many units. entral supervision secures that incorrect operating, like dirty fi lters, detects early. 10
11 xplanatory sketch TR/TX Topvex TR03-06 Topvex TR09-15 H O OS O H SS WV WV SS TS OS GS PS WV WV PS HS T OT OT T G U U R H TS H PT S S RM RG PTS RM U Unit control S fan xtract an SS air temp. sensor TS xtract air temp. sensor OS Outdoor air temp. sensor OT Overheating thermostat T mergency thermostat PS rost protection temp. sensor WV Water valve actuator (accessories) WV Water valve (accessories) H Heat exchanger RM Rotor motor RG Rotor guard O amper outdoor air (accessories) H amper exhaust air (accessories) U Unit control PS rost protection temp. sensor S fan WV Water valve actuator (accessory) xtract fan WV Water valve (accessory) PTS Pressure transmitter supply air fan H Heat exchanger PT Pressure transmitter extract air fan R Rotor control SS air temp. sensor RM Rotor motor TS xtract air temp. sensor GS ilter pressure guard supply air OS Outdoor air temp. sensor G ilter pressure guard extract air HS xhaust air temp. sensor O amper outdoor air (accessory) OT Overheating thermostat H amper exhaust air (accessory) T mergency thermostat Topvex TX03-06 xtract fan S fan SS air temp. sensor OS Outdoor air temp. sensor TS xtract air temp. sensor LH lectrical re-heater battery T mergency thermostat OT Overheating thermostat WH Water heating battery PS rost protection temp. sensor amper by-pass U Unit control O amper outdoor air (accessory) H amper exhaust air (accessory) WV Water valve actuator (accessory) 11
12 Performance TR03 xtract SP 3,0 SP 2,5 SP 2,0 SP 1,5 10V η 8V V V V V xtract 10V V V V V V SP = Specific an Power (kw/m 3 /s) The SP value stated applies to the complete unit. Thermal efficiency With air ratio 1:1 and air humidity at 50%. Sound data The sound data tables indicate the sound power level L w, which should not be confused with the sound pressure level. Surrounding 10V V V V V V
13 Performance TR04 xtract SP 3,0 SP 2,5 SP 2,0 SP 1,5 10V V η 6V V V xtract 10V V V V V SP = Specific an Power (kw/m 3 /s) The SP value stated applies to the complete unit. Thermal efficiency With air ratio 1:1 and air humidity at 50%. Sound data The sound data tables indicate the sound power level L w, which should not be confused with the sound pressure level. Surrounding 10V V V V V
14 Performance TR06 xtract SP 2,5 SP 2,0 SP 1,5 10V η 7,5V ,5V V V V xtract 10V ,5V ,5V V V V SP = Specific an Power (kw/m 3 /s) The SP value stated applies to the complete unit. Thermal efficiency With air ratio 1:1 and air humidity at 50%. Sound data The sound data tables indicate the sound power level L w, which should not be confused with the sound pressure level. Surrounding 10V ,5V ,5V V V V
15 Performance TR09 xtract SP 3,0 SP 2,5 SP 2,0 SP 1,5 10V η 10V V V V V xtract 10V V V V V V SP = Specific an Power (kw/m 3 /s) The SP value stated applies to the complete unit. Thermal efficiency With air ratio 1:1 and air humidity at 50%. Sound data The sound data tables indicate the sound power level L w, which should not be confused with the sound pressure level. Surrounding 10V V V V V V
16 Performance TR12 xtract SP 2,5 SP 1,5 SP 2,0 10V η 10V V V V V xtract 10V V V ,5V V V SP = Specific an Power (kw/m 3 /s) The SP value stated applies to the complete unit. Thermal efficiency With air ratio 1:1 and air humidity at 50%. Sound data The sound data tables indicate the sound power level L w, which should not be confused with the sound pressure level. Surrounding 10V V V V V V
17 Performance TR15 xtract SP 2,5 SP 1,5 SP 2, = 230V 3-fase units = 230V 3-fase units 10V η 8V V V V V xtract 10V V V V V V SP = Specific an Power (kw/m 3 /s) The SP value stated applies to the complete unit. Thermal efficiency With air ratio 1:1 and air humidity at 50%. Sound data The sound data tables indicate the sound power level L w, which should not be confused with the sound pressure level. Surrounding 10V V V V V V
18 Hot water coil TR n extract air temperature of 21 and a heat exchanger effi ciency of 70% has been used for the calculations below. In practice the heat exchanger effi ciency or extract air temperature may be higher, which may give a few degrees higher supply air temperatures than in the below tables. Topvex TR03 HWL Topvex TR04 HWL Topvex TR06 HWL Water temp. 60/40 70/50 80/60 90/70 60/40 70/50 80/60 90/70 60/40 70/50 80/60 90/70 ir flow m 3 /h Outdoor air temp. 0 air temp Water flow l/s Pressure drop kpa apacity kw Outdoor air temp. -10 air temp Water flow l/s Pressure drop kpa apacity kw Outdoor air temp. -20 air temp Water flow l/s Pressure drop kpa apacity kw Outdoor air temp. -30 air temp Water flow l/s Pressure drop kpa , apacity kw Outdoor air temp. -40 air temp Water flow l/s Pressure drop kpa apacity kw Topvex TR03 HWH Topvex TR04 HWH Topvex TR06 HWH Water temp. 60/30 60/30 60/40 60/40 60/30 60/30 60/40 60/40 60/30 60/30 60/40 60/40 irflow m 3 /h Outdoor air temp. 0 air temp ,63 27,69 36,97 32, Water flow l/s 0, Pressure drop kpa apacity kw Outdoor air temp. -10 air temp Water flow l/s Pressure drop kpa apacity kw Outdoor air temp. -20 air temp Water flow l/s Pressure drop kpa apacity kw Outdoor air temp. -30 air temp Water flow l/s Pressure drop kpa apacity kw Outdoor air temp. -40 air temp Water flow l/s Pressure drop kpa apacity kw
19 Hot water coil TR Topvex TR09 HWL Topvex TR12 HWL Topvex TR15 HWL Water temp. 60/40 70/50 80/60 90/70 60/40 70/50 80/60 90/70 60/40 70/50 80/60 90/70 irflow m 3 /h Outdoor air temp 0 air temp Water flow l/s Pressure drop kpa apacity kw Outdoor air temp -10 air temp Water flow l/s Pressure drop kpa apacity kw Outdoor air temp -20 air temp Water flow l/s Pressure drop kpa apacity kw Outdoor air temp -30 air temp Water flow l/s Pressure drop kpa apacity kw Outdoor air temp -40 air temp Water flow l/s Pressure drop kpa apacity kw Topvex TR03 Topvex TR04 Topvex TR06 apacity, kw irflow, m 3 /h air temp. air temp. air temp. 0 > > >30 > > >30 > > > >30 22 Outdoor Outdoor Heater battery, electric TR Outdoor Topvex TR09 Topvex TR09 apacity kw irflow m 3 /h air temp. air temp Outdoor Outdoor Topvex TR12 Topvex TR12 Topvex TR15 apacity kw irflow m 3 /h air temp. air temp. air temp Outdoor Outdoor Outdoor 19
20 imensions TR 43 TR G TR TR øl 15R (½") H I J K øl N TR R (½")
21 imensions TR 32,5 72,5 TR M M M M G H I J K K L R ½" 25 G H TR TR TR N 150 O P I J K L M N O P
22 Technical data TR TR03 L TR03 HW TR04 L TR04 HW TR06 L TR06 HW Voltage V requency Hz Phase ~ 3N 1 3N 3N 3N 3N Input power, fan motors W 2 x x x x x x 1005 Input power, electrical heating battery kw use 3x x13 3x10 3x16 3x10 Weight kg ilter, supply air ilter, extract air TR09 L TR09 HW TR12 L TR12 HW TR15 L TR15 HW Voltage V requency Hz Phase ~ 3N 3N 3N 3N 3N 3N Input power, fan motors W 2 x x x x x x 3380 Input power, electrical heating battery kw 6/15 9/21 15 use 3x16/3x35 3x10 3x25/3x50 3x16 3x35 3x16 Weight kg ilter, supply air ilter, extract air ccessories TR03-06 Topvex TR03 Topvex TR04 Topvex TR06 Repeater 1 0-R230K 0-R230K 0-R230K Shut-off damper Valve actuator QM QM QM Valve, 2-way STV15-0,63 STV15-1,0 STV15-1,0 Valve, 3-way STR15-1,0 STR15-1,6 STR15-1,6 ooling battery, water PGK PGK PGK ooling battery, X coil XR XR XR Step controller. X cooling 2 S2/ S2/ S2/ Plastic housing, step controller IP5 U-K U-K U-K Transformer 230/24 V PSS48 PSS48 PSS48 uct sensor TG-KH/PT1000 TG-KH/PT1000 TG-KH/PT1000 ombi grille VVX 250 VVX 315 VVX 400 Silencer L 250 L 315 LR Timer T 120 T 120 T 120 Presence detector IR24-P IR24-P IR24-P O2 Room sensor (digital 1/0) O2RT-R O2RT-R O2RT-R ilter 5 (extract air) T TR03 5 T TR04 5 T TR06 5 ilter 7 (supply air) T TR03 7 T TR04 7 T TR Used when distance between the unit and control panel is more than 10 meters. 2 (24V). onverts V signal to relay output. 22
23 ccessories TR09-15 Topvex TR09 Topvex TR12 Topvex TR15 Repeater 1 0-R230K 0-R230K 0-R230K -Tool cable T T T Shut-off damper Valve actuator QM QM QM Valve, 2-way STV STV STV Valve, 3-way STR15-2,7 STR20-4,2 STR20-5,6 ooling battery, water PGK PGK PGK ooling battery, X coil XR XR XR uct sensor TG-KH/PT1000 TG-KH/PT1000 TG-KH/PT1000 Silencer LR LR LR Timer T 120 T 120 T 120 Room temp sensor TG-R5/PT1000 TG-R5/PT1000 TG-R5/PT1000 Outdoor sensor, wall mount TG-UH7PT1000 TG-UH7PT1000 TG-UH7PT1000 Presence detector IR24-P IR24-P IR24-P O2 Room sensor (digital 1/0) O2RT-R O2RT-R O2RT-R O2 Room sensor (analog V ) O2RT O2RT O2RT U-tube manometer, fi lter guard MRO MRO MRO ilter 5 (extract air) T TR09 5 T TR12 5 T TR15 5 ilter 7 (supply air) T TR09 7 T TR12 7 T TR Used when distance between the unit and control panel is more than 10 meters. 23
24 Ordering code TR TR Model: TR03, TR04, TR06 Heating coil: electric = L, water = HW vailable power: TR03 L: 3kW TR03 HW: HWL - low power, HWH - high power TR04 L: 4kW TR04 HW: HWL - low power, HWH - high power TR06 L: 6.3 kw TR04 HW: HWL - low power, HWH - high power Right or left model (The side were the supply air is located when viewed from access side) TR Model: TR09, TR12, TR15 Heating coil: electric = L, water = HW vailable power: TR09 L: 6kW alt. 15kW TR09 HW: HWL - low power TR12 L: 9kW alt. 21kW TR12 HW: HWL - low power TR15 L: 15kW TR15 HW: HWL - low power Right or left model (The side were the supply air is located when viewed from access side) V or VV airflow controlling (V= onstant ir Volume, VV= Variable ir Volume) ommunication to MS systems LON xoline/uilt-in Web via TP/IP 24
25 Performance TX03 xtract SP 2,5 SP 1,5 SP 2,0 10V η 10V ,6V ,6V ,6V ,6V = With condensation --- = Without condensation xtract 10V V ,6V ,6V ,6V ,6V Surrounding SP = Specific an Power (kw/m 3 /s) The SP value stated applies to the complete unit. Thermal efficiency With outside temperature -15 º and extract air temperature 25 º. With condensation: 50%Rh. Without condensation: 0%Rh. Sound data The sound data tables indicate the sound power level L w, which should not be confused with the sound pressure level. 10V V ,6V ,6V ,6V ,6V
26 Performance TX04 xtract SP 2,5 SP 1,5 SP 2,0 10V η 6,6V ,6V ,5V ,5V ,5V = With condensation --- = Without condensation xtract 10V ,6V ,6V ,5V ,5V ,5V Surrounding SP = Specific an Power (kw/m 3 /s) The SP value stated applies to the complete unit. Thermal efficiency With outside temperature -15 º and extract air temperature 25 º. With condensation: 50%Rh. Without condensation: 0%Rh. Sound data The sound data tables indicate the sound power level L w, which should not be confused with the sound pressure level. 10V ,6V ,6V ,5V ,5V ,5V
27 Performance TX06 xtract SP 2,5 SP 1,5 SP 2,0 10V V V ,2V ,2V ,7V = With condensation --- = Without condensation xtract 10V V V ,2V ,2V ,7V Surrounding SP = Specific an Power (kw/m 3 /s) The SP value stated applies to the complete unit. Thermal efficiency With outside temperature -15 º and extract air temperature 25 º. With condensation: 50%Rh. Without condensation: 0%Rh. Sound data The sound data tables indicate the sound power level L w, which should not be confused with the sound pressure level. 10V V V ,2V ,2V ,7V
28 Hot water coil TX Topvex TX03 HWL Topvex TX04 HWL Topvex TX06 HWL Water temp. 60/40 70/50 80/60 90/70 60/40 70/50 80/60 90/70 60/40 70/50 80/60 90/70 ir flow m 3 /h Outdoor temp. 0 air temp Water flow l/s Pressure drop kpa apacity kw Outdoor temp. -10 air temp Water flow l/s Pressure drop kpa apacity kw Outdoor temp. -10 open by-pass air temp Water flow l/s Pressure drop kpa apacity kw Outdoor temp. -20 air temp Water flow l/s Pressure drop kpa apacity kw Outdoor temp. -30 air temp Water flow l/s Pressure drop kpa apacity kw Outdoor temp. -40 air temp Water flow l/s Pressure drop kpa apacity kw Topvex TX03 HWH Topvex TX04 HWH Topvex TX06 HWH Water temp. 60/30 60/30 60/40 60/40 60/30 60/30 60/40 60/40 60/30 60/30 60/40 60/40 ir flow m 3 /h Outdoor temp. 0 air temp Water flow l/s Pressure drop kpa apacity kw Outdoor temp. -10 air temp Water flow l/s Pressure drop kpa apacity kw Outdoor temp. -10 open by-pass air temp Water flow l/s Pressure drop kpa apacity kw Outdoor temp. -20 air temp Water flow l/s Pressure drop kpa apacity kw Outdoor temp. -30 air temp Water flow l/s Pressure drop kpa apacity kw Outdoor temp. -40 air temp Water flow l/s Pressure drop kpa apacity kw
29 Heater battery, electric TX Topvex TX03 Topvex TX04 Topvex TX06 apacity, kw ir flow, m 3 /h air temp. air temp. air temp. 0 >30 > >30 > >30 > >30 > > > > > > > > > otted frame = open by-pass Outdoor n extract air temperature of 21 and a heat exchanger effi ciency of 55% has been used for the calculations below. In practice the heat exchanger effi ciency or extract air temperature may be higher, which may give a few degrees higher supply air temperatures than in the above tables. Outdoor Outdoor imensions TX 43 TX G TX TX øl H I J K øl N R (½") 29
30 imensions TX TX K R ½" Technical data TX TX03 L TX03 HW TX04 L TX04 HW TX06 L TX06 HW Voltage V 400V requency Hz Phase ~ 3N 1 3N 3N 3N 3N Input power, fan motors W 2 x x x x x x 1084 Input power, electrical heating battery kw use 3x x25 3x10 3x32 3x10 Weight kg ilter, supply air ilter, extract air
31 ccessories TX03-06 Topvex TX03 Topvex TX04 Topvex TX06 Repeater 1 0-R230K 0-R230K 0-R230K Shut-off damper Valve actuator QM QM QM Valve, 2-way STV15-1.0/0.63 STV15-1.6/1.0 STV15-2.1/1.6 Valve, 3-way STR15-1.6/1.0 STR15-2.1/1.6 STR15-2.7/2.1 ooling battery, water PGK PGK PGK ooling battery, X coil XR XR XR Step controller. X cooling 2 S2/ S2/ S2/ Plastic housing, step controller IP5 U-K U-K U-K Transformer 230/24 V PSS48 PSS48 PSS48 uct sensor TG-KH/PT1000 TG-KH/PT1000 TG-KH/PT1000 ombi grille VVX 250 VVX 315 VVX 400 Silencer L 250 L 315 LR Timer T 120 T 120 T 120 Presence detector IR24-P IR24-P IR24-P O 2 Room sensor (digital 1/0) O2RT-R O2RT-R O2RT-R Water-lock 3 Water-lock Water-lock Water-lock ilter 5 (extract air) T TR03 5 T TX04 5 T TX06 5 ilter 7 (supply air) T TX03 7 T TX04 7 T TX Used when distance between the unit and control panel is more than 10 meters. 2 (24V). onverts V signal to relay output. 3 When risk of condensation in outdoor air side of heat exchanger Model: TX03, TX04, TX06 Heating coil: electric = L, water = HW vailable power: TX03 L: 6kW TX03 HW: HWL - low power, HWH - high power TX04 L: 12kW TX04 HW: HWL - low power, HWH - high power TX06 L: 16kW TX06 HW: HWL - low power, HWH - high power Right or left model (The side were the supply air is located when viewed from access side) Ordering code TX 31
32 SR SX SR07-11 SX04-06 SR04-06 SX03 SR03 S Side connection R Rotating heat exchanger X ross flow heat exchanger Topvex SR/SX is a Plug and play air handling unit with a modern design intended for ventilating offices, day-care centres or used as zone ventilation in larger buildings e.g. schools. To meet the new restricted energy requirements with low SP (Specific an Power) Topvex is equipped with fan motors. -motors consume an average of 30% less energy than motors. In some applications, the saving can be 50% or more. SR has a non-removable rotating heat exchanger. Topvex SR is equipped with a high efficiency rotating heat exchanger with an efficiency of up to 85%. Rotating heat exchangers do not need condense water drainage and is therefore very flexible to install. Topvex SX with its crossflow heat exchanger is normally used where it is a requirement that the supply and exhaust air must be kept separated. The unit have an efficient de-icing function. Topvex SR/SX units have energy saving functions like: - Week schedule. - ool recovering to recover the chilliness in the extract air during warm season. If using an external cooling unit. - emand controlled airflow by using a O 2 /humidity sensor, movement detector etc. - Sum alarm output for central supervision of many units. entral supervision secures that incorrect operating, like dirty fi lters, detects early. 32
33 xplanatory sketch SR/SX SR03-06 H O OS H RM RG S TS U T OT PS SS xtract fan RG Rotor guard S fan U Unit control SS air temp. sensor RM Rotor motor OS Outdoor air temp. sensor H Heater exchanger TS xtract air temp. sensor O amper outdoor air (accessories) T mergency thermostat H amper exhaust air (accessories) OT Overheating thermostat WV Water valve actuator (accessories) PS rost protection temp. sensor WV SR07-11 R H RM U Unit control OT Overheating thermostat (electric heater) S fan PS rost protection temp. sensor (hot water heater) xtract fan PTS Pressure transmitter supply air fan WV Water valve actuator (accessory) PT Pressure transmitter extract air fan H Heat exchanger SS air temp. sensor R Rotor control RM Rotor motor TS xtract air temp. sensor GS ilter pressure guard supply air OS Outdoor air temp. sensor G ilter pressure guard extract air HT Heater O amper outdoor air (accessory) T mergency thermostat (electric heater) H amper exhaust air (accessory) SX03-06 xtract fan S fan SS air temp. sensor OS Outdoor air temp. sensor TS xtract air temp. sensor LH lectrical re-heater battery T mergency thermostat OT Overheating thermostat WH Water heating battery PS rost protection temp. sensor amper by-pass U Unit control H Heat exchanger O amper outdoor air (accessory) H amper exhaust air (accessory) WV Water valve actuator (accessory) 33
34 Performance SR03 xtract SP 3,0 SP 2,0 SP 2,5 SP 1,5 10V η 10V V V V V xtract 10V V V V V V SP = Specific an Power (kw/m 3 /s) The SP value stated applies to the complete unit. Thermal efficiency With air ratio 1:1 and air humidity at 50%. Sound data The sound data tables indicate the sound power level L w, which should not be confused with the sound pressure level. Surrounding 10V V V V V V
35 Performance SR04 xtract SP 3,0 SP 1,5 SP 2,0 SP 2,5 10V η 8V V V V V xtract 10V V V V V V SP = Specific an Power (kw/m 3 /s) The SP value stated applies to the complete unit. Thermal efficiency With air ratio 1:1 and air humidity at 50%. Sound data The sound data tables indicate the sound power level L w, which should not be confused with the sound pressure level. Surrounding 10V V V V V V
36 Performance SR06 xtract SP 2,5 SP 2,0 SP 1,5 10V η 10V ,3V ,3V ,8V ,8V xtract 10V ,3V ,3V ,5V ,5V ,8V SP = Specific an Power (kw/m 3 /s) The SP value stated applies to the complete unit. Thermal efficiency With air ratio 1:1 and air humidity at 50%. Sound data The sound data tables indicate the sound power level L w, which should not be confused with the sound pressure level. Surrounding 10V ,3V ,3V ,5V ,5V ,8V
37 Performance SR07 xtract SP 2,5 SP 2,0 SP 1,5 10V η 10V V V V V xtract 10V V V V V V SP = Specific an Power (kw/m 3 /s) The SP value stated applies to the complete unit. Thermal efficiency With air ratio 1:1 and air humidity at 50%. Sound data The sound data tables indicate the sound power level L w, which should not be confused with the sound pressure level. Surrounding 10V V V V V V
38 Performance SR09 xtract SP 2,0 SP 2,5 SP 1,5 10V η 10V V V V V xtract 10V V V V V V SP = Specific an Power (kw/m 3 /s) The SP value stated applies to the complete unit. Thermal efficiency With air ratio 1:1 and air humidity at 50%. Sound data The sound data tables indicate the sound power level L w, which should not be confused with the sound pressure level. Surrounding 10V V V V V V
39 Performance SR011 xtract SP 2,0 SP 2,5 SP 1,5 10V η 6,5V V V ,5V ,5V xtract 10V ,5V V V ,5V ,5V SP = Specific an Power (kw/m 3 /s) The SP value stated applies to the complete unit. Thermal efficiency With air ratio 1:1 and air humidity at 50%. Sound data The sound data tables indicate the sound power level L w, which should not be confused with the sound pressure level. Surrounding 10V ,5V V V ,5V ,5V
40 Hot water coil SR03-06 n extract air temperature of 21 and a heat exchanger effi ciency of 70% has been used for the calculations below. In practice the heat exchanger effi ciency or extract air temperature may be higher, which may give a few degrees higher supply air temperatures than in the following tables. Topvex SR03 HWL Topvex SR04 HWL Topvex SR06 HWL Water temp. 60/40 70/50 80/60 90/70 60/40 70/50 80/60 90/70 60/40 70/50 80/60 90/70 ir flow m 3 /h Outdoor air temp. 0 air temp Water flow l/s Pressure drop kpa apacity kw Outdoor air temp. -10 air temp Water flow l/s Pressure drop kpa apacity kw Outdoor air temp. -20 air temp Water flow l/s Pressure drop kpa apacity kw Outdoor air temp. -30 air temp Water flow l/s Pressure drop kpa apacity kw Outdoor air temp. -40 air temp Water flow l/s Pressure drop kpa apacity kw Topvex SR03 HWH Topvex SR04 HWH Topvex SR06 HWH Water temp. 60/30 60/30 60/40 60/40 60/30 60/30 60/40 60/40 60/30 60/30 60/40 60/40 ir flow m 3 /h Outdoor temp. 0 air temp Water flow l/s Pressure drop kpa apacity kw Outdoor temp. -10 air temp Water flow l/s Pressure drop kpa apacity kw Outdoor temp. -20 air temp Water flow l/s Pressure drop kpa apacity kw Outdoor temp. -30 air temp Water flow l/s Pressure drop kpa apacity kw Outdoor temp. -40 air temp Water flow l/s Pressure drop kpa apacity kw
41 Hot water coil SR07-11 Topvex SR07 HWL Topvex SR09 HWL Topvex SR11 HWL Water temp. 60/40 70/50 80/60 90/70 60/40 70/50 80/60 90/70 60/40 70/50 80/60 90/70 ir flow m 3 /h Outdoor air temp 0 air temp Water flow l/s Pressure drop kpa apacity kw Outdoor air temp -10 air temp Water flow l/s Pressure drop kpa apacity kw Outdoor air temp -20 air temp Water flow l/s Pressure drop kpa apacity kw Outdoor air temp -30 air temp Water flow l/s Pressure drop kpa apacity kw Outdoor air temp -40 air temp Water flow l/s Pressure drop kpa apacity kw Topvex SR03 apacity, kw ir flow, m 3 /h air temp. 0 >30 >30 > >30 > >30 > >30 > > Outdoor Topvex SR04 Topvex SR04 apacity, kw ir flow, m 3 /h air temp. air temp >30 >30 > >30 > >30 > > > Outdoor Heater battery, electric SR03-06 Topvex SR06 Topvex SR06 apacity, kw ir flow, m 3 /h air temp. air temp >30 >30 > >30 >30 > >30 > > > Outdoor Outdoor Outdoor 41
42 Heater battery, electric SR07-11 Topvex SR07 apacity kw ir flow m 3 /h air temp air temp Outdoor Topvex SR09 apacity kw ir flow m 3 /h air temp air temp Outdoor Outdoor Outdoor Topvex SR11 apacity kw ir flow m 3 /h Outdoor Outdoor Outdoor imensions SR ø315 SR03 15R ½" Min space to door 603 mm 42
43 imensions SR 62 G 15R ½" 111 K J H I I SR04-06 H G H I J K SR SR Min space to door 603 mm SR07-11 K L 15R (½") G M G K L M SR SR SR Min space to door 810 mm 43
44 Technical data SR SR03-L SR03-HW SR04-L SR04-HW SR06-L SR06-HW Voltage/requency V/50 Hz Phase ~ 3N 1 3N 3N 3N 3N Input power, motors W 2x508 2x508 2x1109 2x1109 2x1033 2x1033 Input power, el heating battery kw 6 6/12 9/16 use 3x x16/25 3x10 3x20/32 3x10 Weight kg ilter (/extract) 7/5 7/5 7/5 7/5 7/5 7/5 SR07 L SR07 HW SR09 L SR09 HW SR11 L SR11 HW Voltage/requency V/50Hz Phase - 3N 3N 3N 3N 3N 3N Input power, motors kw 2x1.03 2x1.03 2x1.90 2x1.90 2x3.07 2x3.07 Input power, heater battery kw 3/12* 4.5/15* 6/12*/24* use, unit 3x10 3x10 3x16/10 3x10 3x20/16/16 3x16 use, heaters (with seperate power supply) -/3x20 -/3x25 -/3x20/35 Weight kg ilter (/extract) 7/5 7/5 7/5 7/5 7/5 7/5 * lectric heater (above 6 kw has seperate incoming power supply) ccessories SR03-06 Topvex SR03 Topvex SR04 Topvex SR06 Repeater 1 0-R230K 0-R230K 0-R230K Outdoor set 2 OS SR04 OS SR06 Shut-off damper Valve actuator QM QM QM Valve, 2-way STV15-0,63 STV15-1,0 STV15-1,0 Valve, 3-way STR15-1,0 STR15-1,6 STR15-1,6 ooling battery, water PGK PGK PGK ooling battery, X coil XR XR XR Step controller. X cooling S2/ S2/ S2/ Plastic housing, step controller IP54 U-K U-K U-K Transformer 230/24 V PSS48 PSS48 PSS48 ombi grille VVX 315 VVX 400 VVX 500 Silencer L 315 LR LR Timer T 120 T 120 T 120 Presence detector IR24-P IR24-P IR24-P O 2 Room sensor (digital 1/0) O2RT-R O2RT-R O2RT-R ilter 5 (extract air) RO SR03 5 RO SR04 5 RO SR06 5 ilter 7 (supply air) RO SR03 7 RO SR04 7 RO SR Used when distance between the unit and control panel is more than 10 meters 2 Outdoor/xhaust air hood + Roof 44
45 ccessories SR07-11 Topvex SR07 Topvex SR09 Topvex SR11 Repeater 1 0-R230K 0-R230K 0-R230K -Tool cable T T T Outdoor set 2 OS SR07 OS SR09 OS SR11 Shut-off damper Valve actuator QM QM QM Valve, 2-way STV STV STV Valve, 3-way STR15-2,1 STR15-2,1 STR15-2,7 ooling battery, water PGK PGK PGK ooling battery, X coil XR XR XR Silencer LR LR LR Timer T 120 T 120 T 120 Room temperature sensor TG-R5/PT1000 TG-R5/PT1000 TG-R5/PT1000 Outdoor sensor, wall mount TG-UH/PT1000 TG-UH/PT1000 TG-UH/PT1000 uct sensor TG-KH/PT1000 TG-KH/PT1000 TG-KH/PT1000 Presence detector IR24-P IR24-P IR24-P O 2 Room sensor (digital 1/0) O2RT-R O2RT-R O2RT-R O 2 Room sensor (analog V ) O2RT O2RT O2RT U-tube manometer, fi lter guard MRO MRO MRO ilter 5, or xtract bag fi lter (2pcs/unit) RO SR07 5 RO SR09 5 RO SR11 5 ilter 7, or xtract bag fi lter (2pcs/unit) RO SR07 7 RO SR09 7 RO SR Used when distance between the unit and control panel is more than 10 meters 2 Outdoor/xhaust air hood + Roof SR03-06 Model: SR03, SR04, SR06 Heating coil: electric = L, water = HW vailable power: SR03 L: 6kW SR03 HW: HWL - low power, HWH - high power SR04 L: 6kW alt. 12kW SR04 HW: HWL - low power, HWH - high power SR 06 L: 9kW alt. 16kW SR06 HW: HWL - low power, HWH - high power Right or left model (the side were the supply air is located when viewed from access side) Ordering code SR SR07-11 Model: SR07, SR09, SR11 Heating coil: electric = L, water = HWL vailable power: SR07 L: 3kW alt. 12kW SR07 HW: HWL - low power SR09 L: 4,5kW alt. 15kW SR09 HW: HWL - low power SR11 L: 6kW alt. 12kW or 24kW SR11 HW: HWL - low power Right or left model (access side as viewed looking in the direction of the supply air) xtract duct, top or side connection V or VV airflow controlling (V= onstant ir Volume, VV= Variable ir Volume) ommunication to MS systems LON xoline/uilt-in Web via TP/IP 45
46 Performance SX03 xtract SP 2,5 SP 1,5 SP 2,0 10V η 10V ,5V ,5V ,6V ,6V = With condensation --- = Without condensation xtract 10V V ,5V ,5V ,6V ,6V Surrounding SP = Specific an Power (kw/m 3 /s) The SP value stated applies to the complete unit. Thermal efficiency With outside temperature -15 º and extract air temperature 25 º. With condensation: 50%Rh. Without condensation: 0%Rh. Sound data The sound data tables indicate the sound power level L w, which should not be confused with the sound pressure level. 10V V ,5V ,5V ,6V ,6V
47 Performance SX04 xtract SP 1,5 SP 2,0 SP 2,5 10V ,6V η 6,6V ,5V ,5V ,7V = With condensation --- = Without condensation xtract 10V ,6V ,6V ,5V ,5V ,7V Surrounding SP = Specific an Power (kw/m 3 /s) The SP value stated applies to the complete unit. Thermal efficiency With outside temperature -15 º and extract air temperature 25 º. With condensation: 50%Rh. Without condensation: 0%Rh. Sound data The sound data tables indicate the sound power level L w, which should not be confused with the sound pressure level. 10V ,6V ,6V ,5V ,5V ,
48 Performance SX06 xtract SP 2,5 SP 2,0 SP 1,5 10V V V V V V = With condensation --- = Without condensation xtract 10V V V V V V Surrounding SP = Specific an Power (kw/m 3 /s) The SP value stated applies to the complete unit. Thermal efficiency With outside temperature -15 º and extract air temperature 25 º. With condensation: 50%Rh. Without condensation: 0%Rh. Sound data The sound data tables indicate the sound power level L w, which should not be confused with the sound pressure level. 10V V V V V V
49 Hot water coil SX Topvex SX03 HWL Topvex SX04 HWL Topvex SX06 HWL Water temp. 60/40 70/50 80/60 90/70 60/40 70/50 80/60 90/70 60/40 70/50 80/60 90/70 ir flow m 3 /h Outdoor temp. 0 air temp Water flow l/s Pressure drop kpa apacity kw Outdoor temp. -10 air temp Water flow l/s Pressure drop kpa apacity kw Outdoor temp. -10 open by-pass air temp Water flow l/s Pressure drop kpa apacity kw Outdoor temp. -20 air temp Water flow l/s Pressure drop kpa apacity kw Outdoor temp. -30 air temp Water flow l/s Pressure drop kpa apacity kw Outdoor temp. -40 air temp Water flow l/s Pressure drop kpa apacity kw Topvex SX03 HWH Topvex SX04 HWH Topvex SX06 HWH Water temp. 60/30 60/30 60/40 60/40 60/30 60/30 60/40 60/40 60/30 60/30 60/40 60/40 ir flow m 3 /h Outdoor temp. 0 air temp Water flow l/s Pressure drop kpa apacity kw Outdoor temp. -10 air temp Water flow l/s Pressure drop kpa apacity kw Outdoor temp. -10 open by-pass air temp Water flow l/s Pressure drop kpa apacity kw Outdoor temp. -20 air temp Water flow l/s Pressure drop kpa apacity kw Outdoor temp. -30 air temp Water flow l/s Pressure drop kpa apacity kw Outdoor temp. -40 air temp Water flow l/s Pressure drop kpa apacity kw otted frame = open by-pass 49
50 Heater battery, electric SX Topvex SX03 Topvex SX04 Topvex SX06 apacity, kw ir flow, m 3 /h air temp. air temp. air temp. 0 >30 > >30 > >30 > >30 > > > > > > > > > > Outdoor otted frame = open by-pass n extract air temperature of 21 and a heat exchanger effi ciency of 55% has been used for the calculations below. In practice the heat exchanger effi ciency or extract air temperature may be higher, which may give a few degrees higher supply air temperatures than in the above tables. Outdoor Outdoor imensions SX SX Min space to door 630 mm ø SX04-06 Min space to door 698/824 mm G H I J K L X Y Z SX SX
51 Technical data SX SX03 L SX03 HW SX04 L SX04 HW SX06 L SX06 HW Voltage/requency V/50 Hz Phase ~ 3N 1 3N 3N 3N 3N Input power, motors W 2x496 2x496 2x1069 2x1069 2x1052 2x1052 Input power, el heating battery kw use 3x x25 3x10 3x32 3x10 Weight kg ilter (/extract) 7/5 7/5 7/5 7/5 7/5 7/5 ccessories SX Topvex SX03 Topvex SX04 Topvex SX06 Repeater 1 0-R230K 0-R230K 0-R230K Shut-off damper Valve actuator QM QM QM Valve, 2-way STV15-1.0/0.63 STV15-1.6/1.0 STV15-1.6/1.6 Valve, 3-way STR15-1.6/1.0 STR15-2.1/1.6 STR15-2.7/2.1 ooling battery, water PGK PGK PGK ooling battery, X coil XR XR XR Step controller. X cooling S2/ S2/ S2/ Plastic housing, step controller IP54 U-K U-K U-K Transformer 230/24 V PSS48 PSS48 PSS48 ombi grille VVX 315 VVX 400 VVX 500 Silencer L 315 LR LR Timer T 120 T 120 T 120 Presence detector IR24-P IR24-P IR24-P O 2 Room sensor (digital 1/0) O2RT-R O2RT-R O2RT-R Water-lock 2 Water-lock Water-lock Water-lock ilter 5 (extract air) RO SR03 5 T SX04 5 T SX06 5 ilter 7 (supply air) RO SR03 7 T SX04 7 T SX Used when distance between the unit and control panel is more than 10 meters 2 When risk of condensation in outdoor air side of heat exchanger Model: SX03, SX04, SX06 Heating coil: electric = L, water = HW vailable power: SX03: 6kW SX03 HW: HWL - low power, HWH - high power SX04: 12kW SX04 HW: HWL - low power, HWH - high power SX06: 16kW SX06 HW: HWL - low power, HWH - high power Right or left model (The side were the supply air is located when viewed from access side) Ordering code SX 51
52 unctions included in the Standard, 17S controller: Menu Languages Temperature control ir flow control an control Heat exchanger control Re-heater control old water cooler control X cooling control ool recovering Night cooling (free cooling) emand ventilation xtended running Week schedule amper control larm ommunication More than 20 different languages. onstant supply air. onstant supply air with outdoor temp. compensation. xtract air (cascade). Week timer, two separate running periods/twenty-four hours. Stepless settable between 0-100%. Transformer control. Rotating heat exchanger (on/off). y-pass damper, cross/counter flow exchanger (stepless). Hot water coil (0...10V control signal). lectric heating. xternal coil (0...10V control signal). xternal coil (Step controller S2/ is required, accessory). utomatically recovers the cold in the indoor air to cool down the warmer outdoor air. Night/ree cooling is used during the summer to cool the building night-time by using cool outdoor air, thereby reducing the need for cooling during the day and thereby saving energy. The units have one digital input for extended/forced running using an external signal, e.g. an external timer, movement detector, O 2 -sensor or similar sensor with a voltage free contact. xtended/forced running is when the unit goes from shut down mode, low or medium fanspeed to the chosen fan speed. The units have a digital input for extended/forced running. The function activates by using an external signal from e.g. a push button or a timer. The function can also be activated by using the control panel. xtended running can be set between minutes. Two separate running periods/week day. 24V output to control one or two shut-off dampers. larm messages in clear text. Sum alarm output (24V). ire alarm input (potential free contact). Stop the unit or continuous running. When more than 10 meter cable between the unit and control panel is needed a repeater (0-R accessory) can be used. One 0-R can control up to 6 HU's. Standard xoline and Modbus via RS 485. Option xoline via TP/IP. Option LON. 52
53 unctions included in the dvanced, 28 controller: Menu Languages Temperature control ir flow control an control Heat exchanger control Re-heater control old water cooler control X cooling control ool recovering Night cooling (free cooling) emand ventilation xtended running Yearly schedule amper control larm ommunication -tool software More than 20 different languages. air. air with outdoor temp. compensation. xtract air. ascaded room temperature control. Outdoor temperature dependent switching between room control and supply air control. Outdoor temperature dependent switching between exhaust air control and supply air control. Year-based clock function. This means that a week-schedule with holiday periods for a full year can be set. ach day has up to two individual running periods for normal speed and reduced speed. onstant air volume control, V. onstant duct pressure control, VV. Outdoor temperature compensated air volume/duct pressure. Rotating heat exchanger (stepless). y-pass damper, cross/counter flow exchanger (stepless). Liquid connected exchanger (0...10V control signal or by two digital outputs). Mixing dampers (0...10V control signal). Hot water coil (0...10V control signal). lectric heating. Hot water coil and lectric heating. xternal coil (0...10V control signal). xternal coil (Up to 3-step, binary control). utomatically recovers the cold in the indoor air to cool down the warmer outdoor air. Night/ree cooling is used during the summer to cool the building night-time by using cool outdoor air, thereby reducing the need for cooling during the day and thereby saving energy. In applications with varying occupancy the fan speeds or mixing dampers can be controlled by the air quality as measured by a O 2 -sensor. It is also possible to use a digital input for extended/forced running using an external signal, e.g. an external timer, movement detector or a similar sensor with a voltage free contact. The units have a digital input for extended/forced running. The function activates by using an external signal from e.g. a push button or a timer. The function can also be activated by using the control panel. xtended running can be set between minutes. Year-based clock function. This means that a week-schedule with holiday periods for a full year can be set. ach day has up to two individual running periods for normal speed and reduced speed. igital timer channels for door locks, lighting etc. 24V output to control one or two shut-off dampers. larm messages in clear text. larm priorities, alarms can be given different priority levels, -alarm, -alarm, -alarm or not active. Sum alarm output (24V). ire alarm input (potential free contact). ifferent fan control modes at fire. When more than 10 meter cable between the unit and control panel is needed a repeater (0- R accessory) can be used. One 0-R can control up to 6 HU's. Standard xoline and Modbus via RS 485. Option xoline/uilt-in Web via TP/IP. Option LON. P-based commissioning software. 53
54 ccessories amper for outdoor air ircular damper The circular damper consists of a tubular housing equipped with a damper blade pivoting on an axle. The blade fits into the circular duct. The connection ends are equipped with silicon rubber sealing rings. The damper is made from hot-dip galvanised sheet steel. The shut-off damper is prepared for external insulation and has arrows showing the damper blade position. Rectangular damper The rectangular multi-leaf damper comprises a number of opposed blades, swivelling on nylon bearings in a sheet metal framework. The blades are connected via a system of linkages (protected) on the outside of the frame. The damper is made of hot-dip galvanised sheet steel. The shut-off damper is prepared for external insulation and has arrows showing the damper blade position. Shutter damper is a shut-off damper suitable for Topvex. The damper is provided with 24V motors with spring-return actuators. are made in leakage performance class 3 according to N 1751:1998 nnex.2. Outdoor air dampers are used to prevent the hot water battery from freezing and also prevent cold air to chill down the building if the unit stops. is connected to terminals in the electrical connection box. Maintenance We recommend preventive maintenance of the damper twice per year for optimum performance. If the damper gets dirty, the blade/s should be cleaned. The gasket sealing should be checked and the blade/s axle/s lubricated as necessary. Pressure drop circular damper ps [Pa] m/s imensions circular damper ø ø Pressure drop rectangular damper imensions rectangular damper ombi grid VVX The ombi grid, suitable for mounting on an outside wall is produced from galvanised sheet steel, finished in dark grey enamel. The outside air intake, and exhaust air outlet are separated from each other so that the air cannot short circuit. our screws on the front facilitate dismantling for cleaning of the grid. Mounting: The back plate is first screwed and fitted to the wall. The grid can be mounted with exhaust-air outlet either on the right or on the left. VVX ø
55 ooling battery water WK, cold water-cooling battery for circular ducts. asing of galvanised sheet steel with copper tubes and aluminium fins. Inspection covers for easy cleaning and maintenance. onnection sleeves with rubber seal. Max working pressure 1.6 MPa (16 bar). Technical data WK ir ir ir ir ir ir apacity Water Water flow velocity pressure before before after flow pressure (m 3 /h) (m/s) drop (Pa) ( ) (% RH) ( ) (kw) (l/s) drop (kpa) < , ±1 ø ødy ±2 +8 R½" WK ø H ødy G K L Weight kg kg kg kg kg kg kg H±1 G±3 K±1 G±3 L±5 55
56 PGK PGK, cold water-cooling battery for rectangular ducts. asing of galvanised sheet steel with copper tubes and aluminium fins. ir vent and drain valve included. ondensation tray of stainless steel and condensate connection (R½"). Max working pressure 1.6 MPa (16 bar). or water connection left or right. Two inspection covers for cleaning and maintenance. roplet eliminator as an accessory regardless of air direction. Recommended for air velocities from 3 m/s. R½ H PGK H N R 3/4 40x R 3/4 50x R 3/4 50x R 3/4 60x30* R 3/4 60x35* R1 70x40* R1 80x50* R1 100x50* * use 2 pcs Technical data PGK Water temperature 6/12 ir ir ir ir ir ir Water Water flow velocity pressure before before after apacity flow pressure PGK (m 3 /h) (m/s) drop (0 ) (%RH) (0 ) (kw) (l/s) drop (kpa) m 3 /h m/s Pa 0 %RH 0 kw l/s kpa 400x x x x x x x x N! roplet eliminator must be ordered seperately. Pressure drop at page
57 QM Valve motor, water valve microprocessor based actuator controlled by a V signal from orrigo. voltage 24V. The actuator has automatic stroke adjustment. Technical data voltage ontrol signal Transformer size Stroke Stroke time orce mbient temp. Storage temp. mbient humidity able connection egree of protec. 24 V V 6 V 20 mm 5 s/mm 450 N % RH Screw terminals IP54 This product conforms to the M standard NL N och N STV/STR Water valve/heating water, 2/3-way STV/STR is a 2 and 3-way control valve to control the hotwater to the heating battery. They are intended for use together with the QM actuator. STV Technical data Max. difference pressure 1.6 Mpa. low charac. Square Media temp Media Hot, cold, glycol mixed water or steam onnection Metric female threaded Stroke 15 mm Max leakage 0.1 % by kv Pressure rat. PN16 Rangeabillity 50:1 Mat: ody Rg5* Mat: one Rg5* Stem Stainless steel Packing box Self-adjusting teflon * RG5 = gun metal SS 5204 STR QM 2-way Pressure drop 3-way 1 2 H Weight STV/STR G½" kg 122 The actuator depth is 92 mm mvp kpa kv 0,63 1,0 1,6 2,1 2,7 4,2 5, onnection nut Jam nut 1 0,5 0,4 0,3 0, N! The actuator and the valve have an overlap of approx 15 mm when connected. 0,1 1 0,01 0,05 0,1 0,2 0,3 0, l/s 0,05 0,1 0, m 3 /h 57
58 I HN XR uct coolers with X oil XR are used for central cooling of the ventilation air in ventilation systems. The XR is also used for individual cooling of the air supplied to individual rooms (zones). 8 standard sizes Same model for left-hand or righthand installation (reversible coil). Stainless steel condensate drip tray. droplet eliminator can be fitted regardless of the direction of air flow asily removable drip tray to simplify cleaning and inspection. roplet eliminator We recommend that a droplet eliminator should be installed on the outlet side of the coil if the air velocity is in excess of 2.5 m/s. This prevents water droplets being entrained by the air flow out into the duct system. The collected water is discharged through the stainless steel condensate drip tray. The droplet eliminator is easily accessible after the drip tray has been removed. Operating data Max. operating press.: 2.8 MPa (28 ar) The coils are tested for leakage. esign The casing is made of luzinc-coated sheet steel. The coil has copper tubes and aluminium fins. Stainless steel drip tray for collecting the condensate, with R½ drain connection. Removable drip tray for inspection and cleaning of the coil. Installation The XR is intended for installation in a horizontal duct, with the air flow in either direction (reversible coil). R S 9 ø10 (8x) 9 K M O 9 O R½" XR duct cooler H S R I O K M N roplet eliminator mm mm mm mm mm mm mm mm ø mm onnection R im XR 400x , /2" 40x20 XR 500x , /2" 50x25 XR 500x , /2" 50x30 XR 600x , /8" 60x30 XR 600x , /8" 60x35 XR 700x , /8" 70x40 XR 800x , /8" 80x50 XR 1000x , /8" 100x50 Pressure drop across droplet eliminator N! roplet eliminator must be ordered seperately. Pressre drop, p [Pa] ir velocity, v [m/s] 58
59 apacity, refrigerant R407, 5 º Standard sizes of XR The tables on the following pages give examples of the capacity for each size. If none of these is suitable, we shall be pleased to carry out a computer calculation. ir ir ir ir ir Refrigerant Refrigerant flow pressure drop in in out Output flow pressure drop XR (m 3 /h) (Pa) (º) (% RH) (º) (kw) (kg/h) (kpa) 400x ,8 2, ,8 3,2 75 6, ,9 2,7 63 4, ,4 3,9 90 8, ,5 2,8 65 4, ,2 4, ,3 500x ,8 3,4 80 3, , , ,9 4, ,1 6, , , , ,2 7, ,1 500x ,5 4, , ,3 6, , ,6 5, , ,8 7, , ,3 6, , ,9 8, ,7 600x ,4 5, , ,8 8, , ,5 6, , ,6 9, , ,3 7, , , ,5 600x , , ,4 8, , ,7 7, , , , ,4 8, , , ,6 700x ,7 8, , ,4 12, , ,3 9, ,3 14, , ,5 11, , ,2 16, x ,6 12, , ,3 18, , ,2 14, , ,1 21, , ,4 16, , ,2 24, ,9 1000x ,3 16, , ,9 23, ,9 18, ,6 29, , ,7 21, , ,9 31,
60 Systemair Inhouse studio 2009 rt no. 8077
Specification data. Rotovex SR IAQ. Air handling units Airflow m 3 /h.
Specification data Rotovex SR 07-11 IQ ir handling units irflow 2200-4000 m 3 /h www.systemair.com Rotovex ir Handling unit Rotovex SR IQ is a series of efficient ventilation units de - signed for schools,
More informationVR 400/700 DCV/DC. Good ventilation For dwellings, smaller offices and business premises. com
VR 400/700 V/ Good ventilation or dwellings, smaller offices and business premises www.systemair. com Ventilation has one main aim. It should take away the consumed air that contains all the pollution
More informationTopvex SF02-SF12 Air Handling Unit
Topvex SF02-SF12 Air Handling Unit Installation instructions Document in original language 130324 A004 GB Copyright Systemair AB All rights reserved E&OE Systemair AB reserves the rights to alter their
More informationTopvex SR03, SR04, SR06 Compact Air Handling Unit
Compact Air Handling Unit GB GB Corrigo ver. no. 1.2-1-00 Manufacturer Our products are manufactured in compliance with applicable international standards and regulations. Systemair AB Industrivägen 3
More informationVERSO Air Handling Units
Energy efficient solutions for profitable indoor climate VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P air handling units equipped with recuperation system
More informationVERSO Air Handling Units
VERSO Air Handling Units Energy efficient solutions for profitable indoor climate VERSO Air Handling Units VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P
More informationHeat Recovery Air Handling Units
Heat Recovery ir Handling Units OMEKT Heat recovery air handling Units OMEKT 1 KOMFOVENT OMEKT ir Handling Units Komfovent ir Handling units are made to create healthy indoor climate and ensure efficient
More informationDOMEKT. Residential ventilation units
OMEKT Residential ventilation units OMEKT Komfovent OMEKT OMEKT air handling units (HU) are designed for the ventilation of residential premises. OMEKT is a standardized series of the air handling units
More informationFans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. Topvex SoftCooler TR. Specification data
Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans Topvex SoftCooler TR Specification data 2 Topvex SoftCooler TR Comfort cooling, ready from factory
More informationAir handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses
REC Temovex 4S-EC-RS Experts on indoor climate in low-energy houses RT 4S-EC-RS REC Temovex 4S-EC-RS ECO2 control system for low-energy and passive houses Comprises: - Air flow boost for warm and cold
More informationDOMEKT. Heat Recovery Air Handling Units
Heat Recovery ir Handling Units OMKT Heat Recovery ir Handling Units OMKT KOMFOVNT OMKT air handling units Komfovent air handling units are made to create healthy indoor climate and ensure efficient energy
More informationTopvex SR 09, 11, Topvex TR Compact Air Handling Units
Topvex SR 09, 11, Topvex TR 09-15 Compact Air Handling Units Installation instructions Document in original language 125593 A003 GB Copyright Systemair AB All rights reserved E&OE Systemair AB reserves
More informationAHU N : Range: VERSO VERSO. Heat Recovery Air Handling Units. Plug & Play Energy Saving Smart Design Reliable & Safe
HU N : 07.09.356 Range: VERSO Heat Recovery ir Handling Units VERSO Plug & Play Energy Saving Smart esign Reliable & Safe VERSO ir Handling Units VERSO-S air supply units VERSO-R air handling units with
More informationAir Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses
NEW! REC Temovex Blue 4 Experts on indoor climate in low-energy houses REC Temovex Blue 4 Third generation of our Temovex units! - Dual counterflow heat exchangers with over 9% efficiency * - SFP < 1,
More informationRotary heat Thermal Wheel recovery unit. Plate heat exchanger recovery unit No condensation drain required. Wall mounted
Airflow max. m 3 /hr Plate heat exchanger recovery unit No condensation drain required Rotary heat Thermal Wheel recovery unit Wall mounted False ceiling void mounted Electrical battery Sound isolated
More informationTopMaster Air Handling unit. Technical data
Technical data Contents Page Description of the unit... 3 Design... 4 Technical data Size 030... 5 Size 0... 6 Accessories... 7 Controls... 9 Control functions... 10 Order codes... 11 Fläkt Woods 8180
More informationPRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h
PRODUCT DATA COMFORT 5000 BY NILAN Ventilation & passive heat recovery Commercial Passive heat recovery Ventilation < 5300 m 3 /h COMFORT 5000 The Comfort 5000 is a ventilation unit suitable for central
More informationCorrigo E. Second generation which contains all applications and languages
revision 05 2009 Corrigo E Second generation which contains all applications and languages The controllers in the Corrigo E series are intended for applications within heating, boiler and ventilation control
More informationAIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!
AIR HANDLING UNITS RIS P EKO 3.0 1 2 3 4 fans! Efficient EC E f f i c i e n c y up to 94%! E x t r e m e l y low height! New range - 5 sizes, 20 models! Contents Basic features 4 RIS P EKO 3.0 full range
More informationKOMPAKT. Air Handling Units
ir Handling Units KOMPKT escription of Komfovent kompakt units 2 The new development in KOMPKT REGO range 3 Reasons to choose Komfovent kompakt units 4 ontrol System 6 KOMFOVENT KOMPKT REGO 10 Rotary
More informationPRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h
PRODUCT DATA COMFORT 00 BY NILAN Ventilation & passive heat recovery Commercial Passive heat recovery Ventilation < 00 m /h COMFORT 00 The Comfort 00 is a ventilation unit suitable for central ventilation
More informationPersonalized comfort for offices and shopping malls RANGE OPERATING LIMITS
R-c Personalized comfort for offices and shopping malls iscreet solution in centralized facilities with closed water loop asy installation in false ceiling T-XH-5-I-I SRIPTION Heat Pumps and ooling Units
More informationFresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.
Fresh air unit ALB ALB it s simple and so easy! Air supplied through a heater and filter in a single unit. The ALB fresh air units from Helios provide comfortable room temperatures. Fresh outside air is
More informationPRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h
PRODUCT DATA COMFORT 00 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 800 m /h COMFORT 00 Product description The Comfort 00 is an energy-efficient ventilation
More informationThe Straight Way K Sileo Series
Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans The Straight Way K Series Systemair Sdn Bhd certifies that the K fans shown herein are licensed
More informationPRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h
PRODUCT DATA COMFORT 40 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 40 m /h COMFORT 40 Product description The Comfort 40 is an energy-efficient ventilation
More informationTopMaster Air Handling Unit
TopMaster Air Handling Unit Contents Page Contents......................................2 Unit description................................3 Design........................................4 Technical Details
More informationUNITES TERMINALES ET MINI CTA FIDJI
1 UNITES TERMINALES ET MINI CTA FIDJI 2 Air Handling Unit Fidji Presentation High Effi ciency superposed Heat Recovery Unit, with control factory mounted, for indoor or outdoor installation. Solution adapted
More informationSeries. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater
SUPPLY UNITS Series VENTS PA E Series VENTS PA W A13 control panel A13 control panel Suspended air supply units with the air capacity up to 3350 m 3 /h in the sound- and heat-insulated casing with the
More informationVERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h
VENTILTION equipment VENTILTION equipment content OMEKT Residential ventilation units 1 000 m³/h 15 VERSO Non residential ventilation units 0 34 000 m³/h 61 omekt R 17 omekt R V 19 omekt R 2 F New automatic
More informationeco PREMIUM ENERGY RECOVERY UNIT» Technical instruction
Air Comfort Air Treatment Energy Recovery eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction eco PREMIUM - Technical Instruction REDA 2 Contents Description Applications... 3 Quality & environment...
More informationThe ultimate in air handling units: directly and indirectly fired
KLIMAT The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake
More informationVERSO DOMEKT. Residential ventilation units m³/h. Commercial ventilation units m³/h
VENTILTION equipment VENTILTION equipment content OMEKT Residential ventilation units 1 000 m³/h 12 VERSO ommercial ventilation units 1000 40 000 m³/h 42 omekt R 14 omekt R V 16 omekt R 2 F 17 omekt R
More informationDOMEKT Residential ventilation units
VENTILTION equipment Komfovent equipment SUMMRY Komfovent range Komfovent air handling units create healthy indoor climate ensuring an efficient energy saving. The designed products meet a high quality
More informationFans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. Air Handling Units.
Fans ir Handling Units ir Distribution Products Fire Safety ir urtains and Heating Products Tunnel Fans ir Handling Units atalogue 2012 2 Systemair The Straight Way Systemair was founded in 1974 with a
More informationFLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.
The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution use Air flow rate: 500 to 8500 m 3 /h is a PLUG & PLAY dual-flow ventilation unit equipped with a highly
More information17 Domekt R. Units with a rotary heat exchanger. Domekt RHP Units with a rotary heat exchanger and an integrated heat pump.
VENTILTION equipment VENTILTION equipment SUMMRY Komfovent range Komfovent air handling units create healthy indoor climate ensuring an efficient energy saving. The designed products meet a high quality
More informationVEX100 series Air handling units with cross-flow heat exchanger
Product information - Version 6 VEX100 series Air handling units with cross-flow heat exchanger VEX140: 400-2200 m 3 /h VEX150: 700-3600 m 3 /h VEX160: 1100-5000 m 3 /h VEX170: 1400-8400 m 3 /h Contents
More informationAHU N : Range: VERSO VERSO. Air handling units. Plug & Play Energy Saving Smart Design Reliable & Safe
HU N : 07.09.356 Range: VERSO ir handling units VERSO Plug & Play Energy Saving Smart esign Reliable & Safe VERSO ir Handling Units VERSO-S air supply units VERSO-R air handling units with a rotary heat
More information39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range
PRODUCT SELECTION DATA Plug & play unit (built-in control) Class A+ across entire range Classic/Vertical/ceiling-mounted dualflow units High-efficiency heat recovery unit High performance plug fan High-efficiency
More informationHome Solutions for Residential Ventilation
Fans ir Handling Units ir Distribution Products Fire Safety ir Conditioning ir Curtains and Heating Products Tunnel Fans Home Solutions for Residential Ventilation Technical specification for SVE units
More informationAir handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation
Air handling units KLASIK Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation KLASIK air handling units Customer oriented and unique
More informationSystemair Ventilation units
ystemair Ventilation units Ventilation units irflow 20054 000 m 3 /h ystemair, Norway ystemair B, weden ystemair a/s, Denmark www.systemair.com Residential units VX 400 EV VX 700 EV VR 400 E/700 E VR 400
More informationDryer for semi-commercial laundry applications
ryer for semi-commercial laundry applications 10 eatures alvanized steel cylinder Top, front and side panels standard available in white oor opens 180 for easy loading and unloading Oversized lint filter
More informationCorrigo E - User Manual Ventilation
Corrigo E - User Manual Ventilation DISCLAIMER The information in this manual has been carefully checked and is believed to be correct. Regin however, makes no warranties as regards the contents of this
More informationPURIFICATION SOLUTIONS. R-Series 1. cycling refrigeration compressed air dryers flow capacity: scfm ( Nm 3 /hr)
PURIFITION SOLUTIONS R-Series R cycling refrigeration compressed air dryers flow capacity: 20-2000 scfm (34-3400 Nm 3 /hr) R-Series cycling refrigeration compressed air dryers flow capacity: 20-2000 scfm
More informationFlexit air handling units C2 and UNI 2, 3,4
Flexit handling units C2 and UNI 2, 3,4 energy efficient ventilation for a healthy indoor environment A FOR A HEALTHY INDOOR ENVIRONMENT Energy-efficient ventilation Flexit C2 and UNI 2, 3, 4 The handling
More informationVERSO. Commercial ventilation units 01/03/ Tél
VERSO ommercial ventilation units istribué par ERI : contact@aeria-france.fr KOMFOVENT fabriqué par : U MLV www.komfovent.com SOUS RÉSERVE E MOIFITION SNS PRÉVIS 1/3/218 www.aeria-france.fr Tél 2 51 13
More informationN M AirControl AHU. Control manual
N 10.63 M 03-2016 AirControl AHU Control manual EN CONTENTS PAGE 1 - MONITORING AND CONTROL 2 1.1 The program 2 1.2 The HMI terminal 2 1.3 The controller 4 1.4 Description of the air handling units 4
More informationTechnical Information. Ventilation
Technical Information Ventilation General description Description of units Dimensions and weights Variants Technical data Control system Accessories - unit Accessories - control system VENTILATION 1 General
More informationTopVent Design Handbook
TopVent Design Handbook Recirculation Units and Supply Air Units for Heating and Cooling High Spaces TopVent Content TopVent DHV Recirculation unit for heating high spaces TopVent NHV Recirculation unit
More informationTopvex SR 09, 11, Topvex TR Compact Air Handling Units
Topvex SR 09, 11, Topvex TR 09-15 Compact Air Handling Units Operation and Maintenance Instructions Document in original language 125594 A004 GB Copyright Systemair AB All rights reserved E&OE Systemair
More informationIN LINE MIXED FLOW DUCT FANS AND ELECTRIC HEATER TD-MIXVENT HEATING System
HEATING System fan (from model 25) and a MBE electric heater installed on the discharge side of the fan. + MBE ELECTRIC HEATER MBE heater type - Insulated element rods. - Automatic overheat thermostat
More informationTechnical data DHP-R. A brine-to-water building heat pump in power outputs
brine-to-water building heat pump in power outputs from to 42 kw. illed with R47 (6 ) or 134a (7 ) refrigerant dvanced control with integrated web monitoring Main components...2 Space requirements...3
More informationKOMFORT EC DB Suspended heat recovery air handling units
2018 AIR HANDLING UNITS KOMFORT EC DB Suspended heat recovery air handling units Features Air handling units for efficient supply and exhaust ventilation in flats, houses, cottages and other buildings.
More informationFlexit air handling units UNI 2, 3 og 4
Flexit handling units UNI 2, 3 og 4 energy efficient ventilation for a healthy indoor environment FOR A HEALTHY INDOOR ENVIRONMENT Energy-efficient ventilation Flexit UNI 2, 3 and 4 The handling units
More informationVERSO-P, VERSO-R Series Air Handling Units with C3 Control System Electrical Installation and Operation Manual
VERSO-P, VERSO-R Series Air Handling Units with C3 Control System Electrical Installation and Operation Manual EN Table of Contents 1. INSTALLATION MANUAL...3 1.1. Air Handling Units Sections Connection...3
More informationCLIMASTER ZCF AIR HANDLING UNITS
CLIMASTER ZCF AIR HANDLING UNITS From 1 September 2013, EXHAUSTO has taken over Novenco s activities within sales and production of land-based climate control systems. Inquiries relating to the products
More informationEnergy-efficient heat source provides comfort in large rooms
AIR HEATER NOZ NOZ air heater Energy-efficient heat source provides comfort in large rooms When it comes to providing large, and often high buildings, with the best possible source of efficient heating
More informationManual for the integration in BMS/GTC
Manual for the integration in BMS/GTC Communication parameters MODBUS RTU and BACNET COMMUNICATION UTBS PRO-REG Software Version 3.6 EN ÍNDEX 1. GENERALITIES...2 1.1. Introduction...2 1.2. signals types...2
More information290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING
Fresh air boxes ALB Comfortable climate with pre-heated, filtered supply air. Ingeniously practical: Supply air, heating and filter in a single unit. For direct in-duct mounting. The fresh air boxes ALB
More informationC User manual
C10...40 User manual Introduction COORIGO is a completely new range of controllers which has been designed to be easy to use and operate. The controllers have a display and built in panels for operation
More informationkw. Flexair. General description. Main components. CLIMATIC controller. Air cooled rooftop packaged unit
Flexair ir cooled rooftop packaged unit 85 0 kw Main applications Large and light commercial buildings inemas, theatres Industrial buildings and logistic centers Why this choice? Energy efficient solution
More informationInstallation and Service
Systemair is not liable or bound by warranty if these instructions are not adhered to during installation or service. 2013 Copyright Systemair AB Systemair AB can accept no responsibility for possible
More informationDomekt R. Air handling units with a rotary heat exchanger. Operating capacity ranges from 50 to 950 m 3 /h. Advantages of Domekt R units
www.aeria-france.fr 3/11/216 omekt R ir handling units with a rotary heat exchanger. Operating capacity ranges from to 9 m 3. Standard sizes of omekt R units ir flow, m³/s,3,6,8,11,14,17,19,22,25,28 9
More informationAIR HANDLING UNITS ver B
AIR HANDLING UNITS www.salda.lt 2013 ver B EC High efficiency air handling units are supplied with crosscounter flow plate heat exchangers. AHU is used for ventilation of houses and other heated areas.
More informationBENSON.... Variante3 Fired Unit Heaters...
NSON Variante3 as ired Unit Heaters 3 Variante... as ired Unit Heaters... The new Variante3 builds on the technical excellence of the previous range to provide cost effective and robust heating for industrial
More informationSuxess Compact Top HEALTHY INDOOR ENVIRONMENT WITH ENERGY EFFICIENT VENTILATION
Suxess Compact Top HEALTHY INDOOR ENVIRONMENT WITH ENERGY EFFICIENT VENTILATION Quality and performance with skills and tradition Suxess is based in Enköping, Sweden, where we both develop and produce
More informationWZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors
High Efficiency ir to Water Split System Heat Pumps With E.V.I. ompressors -20 +43 +65 HP E.V.I..O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor
More informationSauter flexotron 800 ventilation Manual
Manual P100012082 Table of contents DISCLAIMER The information in this manual has been carefully checked and is believed to be correct. Fr. Sauter AG however, makes no warranties as regards the contents
More informationSilencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter
VALLOX Product Code: 3158400 L 3158410 R SILENCER (OPTIONAL) INSTRUCTIONS FOR USE AND MAINTENANCE WATER CIRCULATED POST-HEATING UNIT (OPTIONAL) ELECTRIC POST-HEATING UNIT (OPTIONAL)) PREHEATER (OPTIONAL)
More informationSeries VENTS VUT R WH ЕС
AIR HANDLING UNITS WITH HEAT RECOVERY Series VENTS EH ЕС Series VENTS WH ЕС Air handling units with the air capacity up to 1500 m 3 /h in soundand heat-insulated casing with integrated electric heater.
More informationC-series Controllers for air handling systems
C-series Controllers for air handling systems Corrigo, C-series, is a range of digital controllers for air-handling systems designed to be easy to use and operate, having a large capacity, and a high degree
More informationHeat Recovery Unit HERU. web-version
Heat Recovery Unit HERU web-version HERU 50 and 75 Heat recovery unit HERU is designed to suit places like houses, offices and other buildings where there is a big demand for high temperature efficiency,
More informationCONTENT: VEX308 Decentralised ventilation VEX308
CONTENT: VEX308 Decentralised ventilation VEX308 VEX308 Decentralised ventilation Download all product data on VEX308 General VEX308 - decentralised ventilation for schools, institutions and offices A
More informationOperation and Maintenance Instructions
Compact Air Handling Unit Operation and Maintenance Instructions Item# 415005 2015-06-23 Contents 1 Warnings...1 2 Product Description...1 2.1 Internal Components Topvex TR800-4000...1 2.2 Description
More informationFan heater SWT Ceiling mounted fan heater with water heat
Fan heater heat 3 models Fan heater Ceiling mounted fan heater with water heat Application The fan heater is used for heating entrances, stores, industrial premises, workshops, sports halls, garages and
More informationTopvex SX/C, Topvex TX/C Air Handling Unit
Topvex SX/C, Topvex TX/C Air Handling Unit Operation and Maintenance Instructions Document in original language 131678 A003 GB Contents 1 Warnings...1 2 Product Description...2 2.1 Internal components...2
More information50CO. Close Control Unit. Wide range of chilled water cabinets. Compact and attractive design. EC motor for energy savings. Auto-adaptive control
PRODUCT selection data Wide range of chilled water cabinets Compact and attractive design EC motor for energy savings Auto-adaptive control Easy to install Close Control Unit 50CO Translation of the original
More informationHorizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9
ERV/ HRV CONTENTS Horizontal rotor heat recovery ventilation unit RH 5 Vertical rotor heat recovery ventilation unit RV 9 Suspended plate heat recovery ventilation unit CFP Horizontal plate heat recovery
More informationPre-programmed room controller with communication
revision 02 2016 RC-C3 Pre-programmed room controller with communication RC-C3 is a complete pre-programmed room controller from the Regio Midi series intended to control heating and cooling in a zone
More informationCAW Ceiling-mounted fan heaters for hot water
Ceiling-mounted fan heaters for hot Ceiling-mounted fan heaters for hot Ceiling-mounted fan heaters for hot ceiling-mounted fans are used for heating entrances, warehouses, industrial premises, workshops,
More informationPrimo Hotel. General. Indoor climate units for hotel rooms
Indoor climate units for hotel rooms General Primo Hotel indoor climate unit Ceiling-mounted indoor climate units for ventilation, cooling and heating High capacity; occupies little space Dry system without
More information... Variante -4E Gas Fired Unit Heaters... ErP. ErP Lot 21 Seasonal Efficiency compliant
... Variante -4 as ired Unit eaters... rp 2018 rp Lot 21 Seasonal fficiency compliant Variante 4... as ired Unit eaters... The new Variante 4 builds on the technical excellence of the previous range to
More informationAIR HANDLING UNITS ASSET REFERENCE: DESIGN AHU 1 AHU 2
AIR HANDLING UNITS DESIGN System INFORMATION No off Access Handing Viewed in direction of supply air Finish / Colour Duct Connections Height: Width Velocity: Design Airflow (m3/s) Supply Fan Ability Supply
More informationCONTENT: VEX300C Ceiling units VEX320C/330C
CONTENT: VEX300C Ceiling units VEX320C/330C VEX300C Ceiling units Download all product data on VEX320C-VEX330C General VEX300C Ceiling units VEX300C ceiling units are very compact, making them ideal for
More informationVEX250H with rotary heat exchanger and EXact control system
3003433-2014-04-11 VEX250_EXact VEX250H with rotary heat exchanger and EXact control system Unit supplied with (factory fitted): Compact filter FP Filter bag FB Trim damper and blowout zone,tb250 The following
More informationGLOBAL LP. Ceiling-mounted ventilation unit with plate heat exchanger
Ceiling-mounted ventilation unit with plate heat exchanger Ventilation unit with plate heat exchanger for commercial applications. Well-suited for both newly constructed buildings and renovation projects
More informationCopyright AB Regin, Sweden, Corrigo E manual Ventilation application
Copyright AB Regin, Sweden, 2013 Corrigo E manual Ventilation application DISCLAIMER The information in this manual has been carefully checked and is believed to be correct. Regin however, makes no warranties
More informationThe ultimate in air handling units: directly and indirectly fired
AHU The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake
More informationRoof Fan DVG EC. Smoke extraction and daily ventilation in one!
Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans Roof Fan DVG EC Smoke extraction and daily ventilation in one! C/12min 12 C 2 Roof Fan DVG EC
More informationAegean Range. A new range of fan coils for heating and cooling commercial applications
egean Range new range of fan coils for heating and cooling commercial applications How Fan Coils work Fan Coils provide heating and cooling solutions for a wide range of applications. Fan Coil Unit (FCU)
More informationREAD AND SAVE THESE INSTALLATION INSTRUCTIONS
Nomenclature: D F I 0 0 H : Open coil element T: Tubular element F: Finned tubular element I: Slip in type F: Flange type 0: No screen left of the heater 1: Screen left of the heater 0: No screen right
More informationCADB/T-D DP25 F7 Series CADB/T-DI DP25 F7 CADB/T-DC DP25 F7. Heat recovery units CADB/T-D
CONFIGURLE cross-flow heat RECOVERY DP25 F7 Series I DP25 F7 C DP25 F7 housed in galvanised steel boxes, white plastic coated, with a 25 mm thick double wall, class M0 fire proof thermal and acoustic insulation,
More informationPre-programmed room controller with communication and hidden setpoint
revision 02 2016 RC-C3H Pre-programmed room controller with communication and hidden setpoint RC-C3H is a complete pre-programmed room controller from the Regio Midi series intended to control heating
More informationINDUSTRIAL AIR CURTAIN. IndAC 2
INDUSTRIAL AIR CURTAIN IndAC IndAC industrial air curtain High climate separation efficiency with the IndAC industrial air curtain Optimal climate separation The Biddle IndAC industrial air curtain, is
More informationPRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h
PRODUCT DATA COMFORT 300 TOP BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 325 m 3 /h COMFORT 300 TOP Product description The Comfort 300 Top is an energy-efficient
More informationOutstanding Performance; Application Flexibility
PORTLE HILLER4EP2 SERIES Outstanding Performance; pplication Flexibility EP2 Series Portable hillers are designed for 4 to 43 ton applications. Units are available in air-cooled, water-cooled and remote
More informationThe ultimate in air handling units: directly and indirectly fired
AHU The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake
More informationPRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h
PRODUCT DATA COMFORT 450 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 450 m 3 /h COMFORT 450 Product description The Comfort 450 is an energy-efficient ventilation
More information