Heat Recovery Air Handling Units

Size: px
Start display at page:

Download "Heat Recovery Air Handling Units"

Transcription

1 Heat Recovery ir Handling Units OMEKT

2

3 Heat recovery air handling Units OMEKT 1

4 KOMFOVENT OMEKT ir Handling Units Komfovent ir Handling units are made to create healthy indoor climate and ensure efficient energy saving. Products are designed and produced in conformance with high quality and performance requirements. ll components and parts of the units are accurately selected and assembled to achieve the best results in operation. Reliability of the products is based on the deep attention to the details. Your family health protection Units efficiently clean the air from the particulates, allergens, dust and maintain healthy indoor climate. Energy Efficient Silent operation. Reduces expenses for heating, saves electric energy. ue to the efficient heat exchangers which recover up to 9% of exhaust air to warm up the supplied air, the heating expences are reduced up to 0%. Highly efficiencient E (electronically commutated) motors use 50% less energy than (alternating current) motors with voltage control. The special control system designed by our qualified engineers contributes to saving energy. Reliable and durable ouble quality control system. ir handling units efficiency is measured in a new modern laboratory. Units are tested in the independent laboratories in Switzerland and Germany. ouble anticorrosive units casing protection. Wide range of air handling units We are offering an extremely wide range of air handling units in order to fulfil our customers needs. User friendly control system Modern and attractive control panels enable a customer to select the desirable functions, set and change parameters as well as observe the ventilation processes on L screen. KOMFOVENT OMEKT ir Handling Units are intended for residential premise ventilation within 0m to 50m. Two functions in one unit: 1. Ventilates premise: ensures balanced ventilation with heat recovery supplying fresh air and extracting the used one.. Possibility to connect a kitchen hood or any other extraction device. Special design of the units no need to specify the inspection side it is both right and left hand in one. Ventilation units with integrated automatic control are fully prepared for installation: just PLUG & PLY. wide range and extremely compact size of the units allow the customer to mount them not only in the new premise but also in the renovated ones. U MLV reserves the right to introduce changes of parameters and sizes in the process of improvement of the air handling units.

5 Quick KOMFOVENT OMEKT Unit Selection KOMFOVENT OMEKT REGO ventilation units with rotary heat exchanger omekt REGO units 00VE 00VE 50PE 00PE 600HE 00VW* 00VW* 50PW* 00PW* 600HW* Vertical (top connection) Suspended (ceiling or wall mounted) Horizontal (sides connection) Residential area, m ~10 ~160 ~10 ~00 ~50 Motor type E E E E E Supply and exhaust air flow under pressure Thermal efficiency of rotary heat exchanger up to, % m /h Pa KOMFOVENT OMEKT REU ventilation units with plate heat exchanger omekt REU units 00VE 00VE 50VE 500PE 00VW* 00VW* 50VW* 500PW* Vertical (top connection) Suspended Residential area, m ~10 ~180 ~180 ~50 Motor type E E E E Supply and exhaust air flow under pressure Thermal efficiency of plate heat exchanger up to, % m /h Pa Notes: E electrical heater, W hot water heater * uct mounted water air heater must be ordered additionally to be installed in the duct U MLV reserves the right to introduce changes of parameters and sizes in the process of improvement of the air handling units.

6 Heat Exchangers in Komfovent ventilation units The operating principle of the REGO ventilation unit with nonfreezing rotary heat exchanger Rotary heat exchangers work on the principle of heat recovery: rotating aluminium drum absorbs heat of the exhaust air and warms up the air supplied to the ventilated room. dvantages of the Rotary Heat Exchanger: High efficiency factor up to 90%. Rotary heat exchanger allows to reduce energy consumption for warming up the supply air by approximately times. ompact. Non-freezing in comparison with the cross flow plate heat exchangers. share of the exhaust air moisture is transferred to the air supplied to the ventilated room. ools down the supply air in summer in a conditioned space. No need in drainage. s w -16,8 0 tested in -,0 0 i t z e r l a n d Extracted air from premise Supplied air Outdoor air Exhausted air outside +, ,6 0 90% The operating principle of the REU ventilation unit with cross flow plate heat exchanger The heat of the exhaust air is transferred to the supply air through aluminium plates of the heat exchanger. ir flows through the heat exchanger crosswise. Unit design prevents penetration of the exhaust air to the fresh air flow. Efficiency factor for the plate-type heat exchangers approximates to 9%. dvantages of the Plate Heat Exchanger: In the process of ventilation the heat of the exhaust air is recovered to the supplied air - the unit allows up to 9% of heat recovery. Totally separated air flows. Special solution of using double plate heat exchangers reduces the risk of frosting. -,0 0 -, 0 +,0 0 Extracted air from premise Supplied air Outdoor air Exhausted air outside Intermediate moisture removal +15,6 0 9% dvantages of the units with E motors: Silent operation noise level is 5 7 d() lower than in the units with motors. Lower energy consumption highly efficient E motors. E motors have a wide and consistent range of speed control (from 0 to 100%). Therefore, the ventilation device can operate on the exactly set point - consumers can save up to 50% of the energy and maintenance costs. There are no parts inside the motor that would require periodic maintenance. E motors have an additional electronic protection against overheating inside, exceeding the permissible current, short circuit, etc. Longer operation life. U MLV reserves the right to introduce changes of parameters and sizes in the process of improvement of the air handling units.

7 Vertical unit OMEKT REGO 00 Unit is specially designed to be integrated into the kitchen furniture over the cooker. Its extremely compact size gives us a perfect possibility of simple mounting in a new flat, renovated premise, etc. Unit is applicable to ventilate the premise up to 10m. Ventilation unit is fully prepared for exploitation. Integrated automatic control with the wall mounted panel which is handy and simple in use ensures the most economic unit functioning and necessary control. Unit REGO 00 performs two functions: 1. ventilates premise: ensures balanced ventilation with heat recovery supplying fresh air and extracting the used one,. extracts the used air through kitchen hood: during cooking a user switches on the hood and the air is extracted through the hood by the unit. Kitchen hood has a specially designed damper inside. The air flow through the hood is adjusted with it. NOTE: There is no danger of rotary wheel greasing because air flows are not mixing in the unit when you are cooking! WHY? ecause when you are cooking you switch on a cooker hood and it opens an internal by-pass damper by this action. Used air from cooking and fumes is extracted by exhaust fan and directed to the by-pass, without getting into rotor. Extract air fan can be easily taken out for cleaning when it is needed. Operation principle: when kitchen hood is switched ON Operation principle: when kitchen hood is switched OFF Extract through kitchen hood Extracted air from premise Supplied air Outdoor air Exhausted air outside Extracted air from premise Supplied air Outdoor air Exhausted air outside U MLV reserves the right to introduce changes of parameters and sizes in the process of improvement of the air handling units. 5

8 Vertical Units OMEKT REGO 00 Highly efficient rotary heat exchanger recovers up to 89% of heat. REGO 00 special design has a big advantage: user does not need to specify unit s inspection side. This unit is both rightand left- hand in one. Front and back covering panels are easily removable this way, when installing it, the unit must be only turned around to get the required inspection side and ducts connection. Integrated automatic control with the wall mounted panel or touch sensitive PLUS which is handy and simple in operation ensures the most economic unit functioning and necessary control. PLUS REGO 00 (Shown as left) F REGO 00 (Shown as right) F 15(5x) E F E Explication 1 Rotary heat exchanger Supply air filter Exhaust air filter Supply fan 5 Exhaust fan 6 Electric air heater 7 utomation control system E F Outdoor intake Supply air Extract indoor Exhaust air Kitchen hood connection (by-pass extraction without heat recovery) dditional extraction connection (by-pass extraction without heat recovery) 6 U MLV reserves the right to introduce changes of parameters and sizes in the process of improvement of the air handling units.

9 Technical information REGO-00VE-- REGO-00VW--* E E Supply voltage V/Hz ~0 / 50 / 1 phase Maximal operating current Input fans power W x 70 x 70 Heater capacity kw Unit size (height x width x depth) mm 660 x 600 x 0 uctwork connection mm 5 x 15 Filter for supply/exhaust air mm 85 x 10 x 6-F7 Unit weight kg Unit color RL 9010 * For more detailed information look at the hot water duct air heater H specification. REGO 00VE-E performances ir volume flowrate, m /s 0 0,0 0,0 0,06 0,08 00 Temperature efficiency, η t η t 95 Energy recovery, kw kw,5 50 SFP 1 % 90 85,5 Static pressure, Pa SFP 0, ir volume flowrate, m /h 1,5 SFP 0,5 50 pplication: - RH 8% outdoor 1 RH 5% indoor L W, d() ir volume flowrate, m /h P[kW] = SFP[kW/(m /s)] V [m /s]; SFP is shown for one fan. Performance data: filter F7. Note: characteristics explanation is available on the page 17. REGO 00 coustic data 6Hz 15Hz 50Hz 500Hz 1000Hz 000Hz 000Hz 8000Hz d() Supply air flow Inlet Outlet Extract air flow Inlet Outlet Kitchen hood inlet dditional inlet Surrounding ( pl., m) U MLV reserves the right to introduce changes of parameters and sizes in the process of improvement of the air handling units. 7

10 Vertical units OMEKT REGO 00 Extremely compact unit in size and high energy efficient Highly efficient rotary heat exchanger recovers up to 90% of heat. Unit compact size and high efficiency offer the best choice to ensure healthy microclimate in your apartments or small houses. Unit is applicable to ventilate the premise up to 180m. Unit is designed to ensure ventilation in the premise and may be connected with a kitchen hood via an additional duct. ny exhaust air diffuser may be connected instead of a kitchen hood to by-pass duct connection (to extract air from bathroom, laundry, etc.). Integrated automatic control with the wall mounted panel or С PLUS, which is handy and simple in operation ensures the most economic unit functioning and necessary control. PLUS REGO 00 (Shown as left) E REGO 00 (Shown as right) 6 E E Explication 1 Rotary heat exchanger Supply air filter Exhaust air filter Supply fan 5 Exhaust fan 6 Electric air heater 7 utomation control system Outdoor intake Supply air Extract indoor Exhaust air E Extraction from the kitchen or other premise (by pass extraction without heat recovery) 8 U MLV reserves the right to introduce changes of parameters and sizes in the process of improvement of the air handling units.

11 Technical information REGO-00VE-- REGO-00VW--* E E Supply voltage V/Hz ~0 / 50 / 1 phase Maximal operating current Input fans power W x 70 x 70 Heater capacity kw Unit size (height x width x depth) mm 56 x 600 x 95 uctwork connection mm x 160, 1 x 15 Filter for supply/exhaust air mm 50 x 10 x 6-F7 Unit weight kg Unit color RL 9010 * For more detailed information look at the hot water duct air heater H specification. REGO 00 performances Temperature efficiency, η t Energy recovery, kw ir volume flowrate, m /s 0 0,0 0,0 0,06 0,08 00 η t 9 kw 5 Static pressure, Pa SFP 0,75 SFP 0,5 SFP 0, SFP 0,5 % ir volume flowrate, m /h 1 50 pplication: - RH 8% outdoor 1 RH 5% indoor L W, d() ir volume flowrate, m /h P[kW] = SFP[kW/(m /s)] V [m /s]; SFP is shown for one fan. Performance data: filter F7. Note: characteristics explanation is available on the page 17. REGO 00 coustic data 6Hz 15Hz 50Hz 500Hz 1000Hz 000Hz 000Hz 8000Hz d() Supply air flow Inlet Outlet Extract air flow Inlet Outlet Kitchen hood inlet Surrounding ( pl., m) U MLV reserves the right to introduce changes of parameters and sizes in the process of improvement of the air handling units. 9

12 False-ceiling units OMEKT REGO 50 Unit s height is only 10mm so it can be easily mounted in any convenient place. Rotary heat exchanger ensures high heat recovery and thermal efficiency up to 87%. Special unit s design with extremely low height allows us to mount it horizontally, hiding by false-ceiling or vertically near the wall. Unit REGO 50 may ventilate premise up to 100m. It is intended for ventilation of flats, apartments, small houses, as well as classrooms, small offices and conference rooms. Integrated automatic control with the wall mounted panel or С PLUS, which is handy and simple in operation ensures the most economic unit functioning and necessary control. PLUS REGO 50 (Shown as right) 0 5 E (x) REGO 50 (Shown as left) Explication 1 Rotary heat exchanger Supply air filter Exhaust air filter Supply fan 5 Exhaust fan 6 Electric air heater dditional connection for air 7 extraction from kitchen hood or other extraction device 8 utomation control system Outdoor intake Supply air Extract indoor Exhaust air E Exhaust air from kitchen hood or other premises 10 U MLV reserves the right to introduce changes of parameters and sizes in the process of improvement of the air handling units.

13 Technical information REGO-50PE-- REGO-50PW--* E E Supply voltage V/Hz ~0 / 50 / 1 phase Maximal operating current Input fans power W x 105 x 105 Heater capacity kw Unit size (height x width x depth) mm 10 x 890 x 550 uctwork connection mm x 160, 1 x 15 Filter for supply/exhaust air mm 78 x 58 x 6-F7 Unit weight kg 1 1 Unit color RL 9010 * For more detailed information look at the hot water duct air heater H specification. REGO 50 performances ir volume flowrate, m /s Fan static pressure, Pa 0 0,0 0,0 0,05 0,06 0, SFP 1, SFP SFP 0,75 Temperature efficiency, η t % η t pplication: - RH 8% outdoor 1 RH 5% indoor Energy recovery, kw 7 0, ir volume flowrate, m /h kw 5,5,5,5 1,5 1 L W,d() 0 SFP 0, ir volume flowrate, m /h P[kW] = SFP[kW/(m /s)] V [m /s]; SFP is shown for one fan. Performance data: filter F7. Note: characteristics explanation is available on the page 17. REGO 50 coustic data 6Hz 15Hz 50Hz 500Hz 1000Hz 000Hz 000Hz 8000Hz d() Supply air flow Inlet Outlet Extract air flow Inlet Outlet Kitchen hood inlet Surrounding ( pl., m) U MLV reserves the right to introduce changes of parameters and sizes in the process of improvement of the air handling units. 11

14 False-ceiling units OMEKT REGO 00P Unit s height is only 10 mm. High thermal efficiency is reaching up to 88% because of two rotors used in the unit. Unit REGO 00P is applicable for the ventilation of premise up to 180m area. It is intended for ventilation of apartments, small houses, conference rooms. In spite of low unit s height, thermal efficiency in REGO 00P reaches up to 88% because of two motors used in the unit. y-pass or any other exhaust air diffuser may be connected instead of a kitchen hood to by-pass duct connection (to extract air from bathroom, laundry, etc.). Integrated automatic control with the wall mounted panel or С PLUS, which is handy and simple in operation ensures the most economic unit functioning and necessary control. PLUS REGO 00P (Shown as right) 0 5 E (x) REGO 00P (Shown as left) Explication 1 Rotary heat exchanger Supply air filter Exhaust air filter Supply fan 5 Exhaust fan 6 Electric air heater 7 dditional connection for air extraction from kitchen hood or other extraction device 8 utomation control system Outdoor intake Supply air Extract indoor Exhaust air E Exhaust air from kitchen hood or other premise 1 U MLV reserves the right to introduce changes of parameters and sizes in the process of improvement of the air handling units.

15 Technical information REGO-00PE-- REGO-00PW--* E E Supply voltage V/Hz ~0 / 50 / 1 phase Maximal operating current Input fans power W x 165 x 165 Heater capacity kw Unit size (height x width x depth) mm 10 x 10 x 650 uctwork connection mm x 00, 1 x 15 Filter for supply/exhaust air mm 78 x 58 x 6-F7 Unit weight kg 6 6 Unit color RL 9010 * For more detailed information look at the hot water duct air heater H specification. REGO 00P performances ir volume flowrate, m /s Temperature efficiency, η t Energy recovery, kw Fan static pressure, Pa 0 0,0 0,08 0,1 0,16 0, SFP 1, SFP SFP 0,75 50 SFP 0,5 L W,d() ir volume flowrate, m /h % η t pplication: - RH 8% outdoor 1 RH 5% indoor ir volume flowrate, m /h kw P[kW] = SFP[kW/(m /s)] V [m /s]; SFP is shown for one fan. Performance data: filter F7. Note: characteristics explanation is available on the page 17. REGO 00P coustic data 6Hz 15Hz 50Hz 500Hz 1000Hz 000Hz 000Hz 8000Hz d() Supply air flow Inlet Outlet Extract air flow Inlet Outlet Kitchen hood inlet Surrounding ( pl., m) U MLV reserves the right to introduce changes of parameters and sizes in the process of improvement of the air handling units. 1

16 Horizontal units OMEKT REGO 600 Extremely compact design with high efficiency up to 89%. Unit REGO 600 is applicable for the ventilation of premise up to 50 m and is intended for ventilation of big apartments, medium houses, conference rooms, etc. High efficiency unit with compact design can be easily installed in new premise as well as in renovated ones. The width of REGO 600 without side panels is only 70 mm. It is easy to carry such a unit into the attic through the narrow stairwell or other hard approachable places. The unit has an additional connection for air extraction from kitchen hood or other extraction device (to extract air from bathroom, laundry, etc.). Integrated automatic control with the wall mounted panel or touch sensitive PLUS which is handy and simple in operation ensures the most economic unit functioning and necessary control. PLUS REGO 600 (Shown as right) (x) E 570 REGO 600 (Shown as left) 15 Explication 1 Rotary heat exchanger Electric air heater Supply air filter Exhaust air filter 5 Supply fan 6 Exhaust fan 7 Power supply cable Outdoor intake Supply air Extract indoor Exhaust air E dditional exhausted air 1 U MLV reserves the right to introduce changes of parameters and sizes in the process of improvement of the air handling units.

17 Technical information REGO-600HE-- REGO-600HW--* E E Supply voltage V/Hz ~0 / 50 / 1 phase Maximal operating current Input fans power W x 155 x 165 Heater capacity kw Unit size (height x width x depth) mm 600 x 1150 x 570 uctwork connection mm x 00, 1 x 15 Filter for supply/exhaust air mm 70 x 5 x 6-F7 Unit weight kg 90 Unit color RL 9010 * For more detailed information look at the hot water duct air heater H specification. REGO 600 performances ir volume flowrate, m /s Fan static pressure, Pa 0 0,0 0,08 0,1 0, SFP 1,5 SFP SFP 0, Temperature efficiency, η t % η t Energy recovery, kw ir volume flowrate, m /h kw SFP 0,5 pplication: - RH 8% outdoor 1 RH 5% indoor L W,d() ir volume flowrate, m /h P[kW] = SFP[kW/(m /s)] V [m /s]; SFP is shown for one fan. Performance data: filter F7. Note: characteristics explanation is available on the page 17. REGO 600 coustic data 6Hz 15Hz 50Hz 500Hz 1000Hz 000Hz 000Hz 8000Hz d() Supply air flow Inlet Outlet Extract air flow Inlet Outlet Kitchen hood inlet Surrounding ( pl., m) U MLV reserves the right to introduce changes of parameters and sizes in the process of improvement of the air handling units. 15

18 Vertical units OMEKT REU 00 ouble plate heat exchanger with crosswise air flows ensures the heat recovery up to 88%. Unit REU 00 is developed and designed to create mechanical ventilation and heat recovery in flats, apartments or other residential premises up to 180m. The supply and exhaust air flows are separated in the unit with plate heat exchanger, that is why heat from the foul air can be recovered as well. We can also recover the heat from the premise with a strong smell, e.g. from kitchen, bathroom, etc. The unit has an additional extraction connection for kitchen hood. Integrated automatic control with the wall mounted panel or touch sensitive PLUS which is handy and simple in operation ensures the most economic unit functioning and necessary control. PLUS REU 00 (Shown as right) E Special design of REU 00 allows the user to choose the needed inspection side (it is both left and right hand). The side panel of the units can be easily removed. fter the needed inspection side is chosen, the unit is turned around and the ducts are connected E REU 00 (Shown as left) 15 E 6 Explication 1 rainage Plate heat exchanger Supply air filter Supply fan 5 Exhaust fan 6 utomation control system 7 Exhaust air filter 8 Electric air heater 9 y-pass damper Outdoor intake Supply air Extract indoor Exhaust air E y-pass damper, extraction without heat recovery 16 U MLV reserves the right to introduce changes of parameters and sizes in the process of improvement of the air handling units.

19 Technical information REU-00VE-- REU-00VW--* E E Supply voltage V/Hz ~0 / 50 / 1 phase Maximal operating current Input fans power W x 70 Heater capacity kw 1.0 Unit size (height x width x depth) mm 710 x 70 x 0 uctwork connection mm 5 x 15 Filter for supply/exhaust air mm 00 x 00 x 6-F7 Unit weight kg Unit color RL 9010 * For more detailed information look at the hot water duct air heater H specification. REU 00 performances ir volume flowrate, m /s 0 0,0 0,0 0,06 0,08 00 SFP 1,5 Temperature efficiency dry, η t η t Energy recovery, kw kw 5 Fan static pressure, Pa SFP 1 SFP 0,5 SFP 0,75 60 % ir volume flowrate, m /h pplication: - RH 8% outdoor 1 RH 5% indoor 1 L W,d() ir volume flowrate, m /h P[kW] = SFP[kW/(m /s)] V [m /s]; SFP is shown for one fan. Performance data: filter F7. Note: characteristics explanation is available on the page 17. REU 00 coustic data 6Hz 15Hz 50Hz 500Hz 1000Hz 000Hz 000Hz 8000Hz d() Supply air flow Inlet Outlet Extract air flow Inlet Outlet Kitchen hood connection Surrounding ( pl., m) U MLV reserves the right to introduce changes of parameters and sizes in the process of improvement of the air handling units. 17

20 Vertical units OMEKT REU 00 Energy efficiency 89%. Energy efficient motors E. Unit is developed and designed to create mechanical ventilation and heat recovery in flats, apartments or other residential premise up to 150 m. High-efficient plate heat exchangers and E motors guarantee the most effective and economical unit operation: up to 89% of energy required for supplied air heating is recovered and used from the exhausted air. Unit is produced with a fully integrated automatic control with the wall mounted panel which is handy and simple in use and ensures the most economical unit functioning and necessary control. PLUS REU 00 (Shown as right) For some units right and left sides are mirrored, but in some units are rotated. hoose the right side of unit installation REU 00 (Shown as left) Explication 1 rainage 160 (x) Plate heat exchanger Supply air filter Supply fan 5 Exhaust air filter 6 Exhaust fan 7 Electric air heater 8 utomation control system y-pass damper Outdoor intake Supply air Extract indoor Exhaust air 18 U MLV reserves the right to introduce changes of parameters and sizes in the process of improvement of the air handling units.

21 Technical information REU 00VEF- PLUS REU 00VWF- PLUS* E E Supply voltage V/Hz ~0 / 50 / 1 phase Maximal operating current Input fans power W x 105 Heater capacity kw Unit dimensions (height x width x depth) mm 660 x 598 x 600 uctwork connection mm Ø 160 Filter for supply/exhaust air mm 5 x 50 x 6-F7 Unit weight kg 55 Unit color RL 9010 * For more detailed information look at the hot water duct air heater H specification. REU 00 performances ir volume flowrate, m /s Fan static pressure, Pa 0 0,0 0,06 0,09 0, SFP 1, SFP 1 60 SFP 0,75 SFP 0,5 Temperature efficiency dry, η t % η t pplication: - RH 8% outdoor 1 RH 5% indoor Energy recovery, kw ir volume flowrate, m /h kw L W,d() ir volume flowrate, m /h P[kW] = SFP[kW/(m /s)] V [m /s]; SFP is shown for one fan. Performance data: filter F7. To calculate the power consumption for E motor use formula: P = SFP*V; where SFP kw/(m /s) and V m /s. REU 00 coustic data 6Hz 15Hz 50Hz 500Hz 1000Hz 000Hz 000Hz 8000Hz d() Supply air flow Inlet Outlet Extract air flow Inlet Outlet Surrounding ( pl., m) k OT k SUM To calculate the sound power L W, d in 8 octave centres* and -weighted** total sound power L W, d() of all air duct openings of the unit (without influence of casing) also to calculate the sound pressure Lp, d in 8 octave centers and -weighted total sound pressure Lp, d() of the casing of the unit (without influence of openings) at the distance of meters for environment of sound reflecting: floor (ceiling) and two near standing walls at the angle of 90 degrees to each other at the standard conditions***, correction coefficients k oct, d and k sum, d() must be algebraically added to the value of the closest acoustic curve of -weighted* total sound power L W, d() from the performance chart (usually of the exhaust outlet of the air handling unit) in the desired working point of the unit. * 8 octave centers - frequencies of: 6, 15, 50, 500, 1000, 000, 000 and 8000Hz, ** -weighting: allowance for human s hearing sensitivity in various frequencies, *** Standard conditions: atmospheric pressure of 101.kpa, temperature of 0 and relative humidity of 50%. U MLV reserves the right to introduce changes of parameters and sizes in the process of improvement of the air handling units. 19

22 Vertical units OMEKT REU 50 ouble plate heat exchanger with crosswise air flows ensures the heat recovery up to 88%. Unit REU 50 is developed and designed to create mechanical ventilation and heat recovery in flats, apartments or other residential premises up to 180m. The supply and exhaust air flows are separated in the unit with plate heat exchanger, that is why heat from the foul air can be recovered as well. We can also recover the heat from the premise with a strong smell, e.g. from kitchen, bathroom, etc. The unit has an additional extraction connection for kitchen hood. Integrated automatic control with the wall mounted panel or touch sensitive PLUS which is handy and simple in operation ensures the most economic unit functioning and necessary control. PLUS REU 50 (Shown as right) E Special design of REU 50 allows the user to choose the needed inspection side (it is both left and right hand). The side panel of the units can be easily removed. fter the needed inspection side is chosen, the unit is turned around and the ducts are connected E REU 50 (Shown as left) 15 E 6 Explication 1 rainage Plate heat exchanger Supply air filter Supply fan 5 Exhaust fan 6 utomation control system 7 Exhaust air filter 8 Electric air heater 9 y-pass damper Outdoor intake Supply air Extract indoor Exhaust air E y-pass damper, extraction without heat recovery 0 U MLV reserves the right to introduce changes of parameters and sizes in the process of improvement of the air handling units.

23 Technical information REU 50VE-- REU 50VW--* E E Supply voltage V/Hz ~0 / 50 / 1 phase Maximal operating current Input fans power W x 17 Heater capacity kw 1.5 Unit size (height x width x depth) mm 710 x 70 x 0 uctwork connection mm 5 x 15 Filter for supply/exhaust air mm 00 x 00 x 6-F7 Unit weight kg Unit color RL 9010 * For more detailed information look at the hot water duct air heater H specification. REU 50 performances ir volume flowrate, m /s 0 0,0 0,08 0,1 00 SFP 1,5 50 SFP 1 Temperature efficiency dry, η t η t Energy recovery, kw kw 5 Fan static pressure, Pa SFP 0,75 SFP 0,5 % ir volume flowrate, m /h 50 pplication: - RH 8% outdoor 1 RH 5% indoor L W,d() ir volume flowrate, m /h P[kW] = SFP[kW/(m /s)] V [m /s]; SFP is shown for one fan. Performance data: filter F7. Note: characteristics explanation is available on the page 17. REU 50 coustic data 6Hz 15Hz 50Hz 500Hz 1000Hz 000Hz 000Hz 8000Hz d() Supply air flow Inlet Outlet Extract air flow Inlet Outlet Kitchen hood connection Surrounding ( pl., m) U MLV reserves the right to introduce changes of parameters and sizes in the process of improvement of the air handling units. 1

24 False-ceiling units OMEKT REU 500 Energy efficiency 9%. Energy efficient motors E. Unit is developed and designed to create mechanical ventilation and heat recovery in flats, apartments or other residential premise up to 00 m. High-efficient plate heat exchangers and E motors guarantee the most effective and economical unit operation: up to 9% of energy required for supplied air heating is recovered and used from the exhausted air. Unit is produced with a fully integrated automatic control with the wall mounted panel which is handy and simple in use and ensures the most economical unit functioning and necessary control. PLUS 0 REU 500 (Shown as left) E (x) Explication 1 rainage Outdoor intake Plate heat exchanger Supply air Supply air filter Extract indoor Supply fan Exhaust air 5 Exhaust air filter E y-pass extraction without heat recovery 6 Exhaust fan 7 Electric air heater REU 500 (Shown as right) 8 utomation control system 9 y-pass damper U MLV reserves the right to introduce changes of parameters and sizes in the process of improvement of the air handling units.

25 Technical information REU 500PEF- PLUS REU 500PWF- PLUS* E E Supply voltage V/Hz ~0 / 50 / 1 phase Maximal operating current Input fans power W x 165 Heater capacity kw Unit dimensions (height x width x depth) mm 1050 x 1180 x 90 uctwork connection mm Ø 00 Filter for supply/exhaust air mm 10 x 00 x 6-F7 Unit weight kg 70 Unit color RL 9010 * For more detailed information look at the hot water duct air heater H specification. REU 500 performances ir volume flowrate, m /s Fan static pressure, Pa 0 0,0 0,08 0,1 0,16 0, SFP 1, SFP SFP 0, SFP 0,5 50 L W,d() Temperature efficiency dry, η t % η t pplication: - RH 8% outdoor 1 RH 5% indoor Energy recovery, kw ir volume flowrate, m /h kw ir volume flowrate, m /h P[kW] = SFP[kW/(m /s)] V [m /s]; SFP is shown for one fan. Performance data: filter F7 Note: characteristics explanation is available on the page 17. REU 500 coustic data 6Hz 15Hz 50Hz 500Hz 1000Hz 000Hz 000Hz 8000Hz d() Supply air flow Inlet Outlet Extract air flow Inlet Outlet Kitchen hood connection Surrounding ( pl., m) U MLV reserves the right to introduce changes of parameters and sizes in the process of improvement of the air handling units.

26 Installation of vertical units KOMFOVENT OMEKT With directly integrated kitchen hood Komfovent (only for REGO 00VE) With separately connected kitchen hood Komfovent With separately connected additional extract air diffusers If a kitchen hood is not used, an extraction diffuser from the bathroom, laundry, or other premise can be connected to the unit as well. alanced ventilation system in the premise When the kitchen hood is switched on, the supply air flow in the unit increases and the exhaust one decreases automatically. This way we can feel the supply/exhaust air flows balance in the premise. Extracted air from premise Extracted air from premise Supplied air Outdoor air Exhausted air outside U MLV reserves the right to introduce changes of parameters and sizes in the process of improvement of the air handling units.

27 Installation of false-ceiling units KOMFOVENT OMEKT Special units design with extremely low heights allows us to mount them horizontally, hiding by the false-ceiling or vertically on the wall. With kitchen hood KOMFOVENT connected via duct With additionally connected extraction diffusers alanced ventilation system in the premise When the kitchen hood is switched on, the supply air flow in the unit increases and the exhaust one decreases automatically. This way we can feel the supply/exhaust air flows balance in the premise. Extracted air from premise Extracted air from premise Supplied air Outdoor air Exhausted air outside U MLV reserves the right to introduce changes of parameters and sizes in the process of improvement of the air handling units. 5

28 utomatic ontrol Komfovent omekt Measurements of the control panel 75 x 75 x 5mm ontrol panel connecting cable (10m) 8 x 0.m control main functions: Setting of ventilation intensity level (1,,). Setting temperature from the panel ( С). hoosing winter/summer operating mode. orrection of ventilation intensity level by potentiometer (inside the unit): for fans with type motors - +/- by one step, for fans with E type motors - by 0 to 100%. OVR activation with an external accessory device. OVR activation by the control panel for the set period of time (0/60/90 min.). Failure is indicated by STOP signal and by red light diode on the control panel. Measurements of the control panel 156 x 79 x 6mm ontrol panel connecting cable (10 m) x 0.m PLUS control main functions: Unit operation mode selection (ON/OFF/UTO). Setting of ventilation intensity level (1,, ). Weekly schedule programming. Temperature maintaining setting. Temperature programming by (+/- 9 С) for the set period of time. Season setting (winter/summer). orrection of ventilation intensity level by potentiometer (inside the unit): for fans with type motors - +/- by one step, for fans with E type motors - by 0 to 100%. OVR activation with an external accessory device OVR activation by the control panel for the set period of time (1 90 min.). Setting fans intensity level for OVR function (only with E motors). Language selection. Failures indication and registration log (history of 50 events with date and time). ontrol panel encoding with PIN. Remote unit intensity control (OVR) OVR (Eng. Override = ignore) function is intended for the remote unit s control with an external accessory device. fter this function is activated the current unit s mode becomes omissible and the unit starts working according to the newly set parameters. pplications of the OVR functions: Maintenance of O quantity in a room by adding an additional O sensor (with relay), the main user-set ventilation rate at higher O will be switched to the maximum intensity until the room is ventilated, and then again will return to the user-defined intensity. Maintaining relative humidity in the room after contacting the external relative humidity sensor (with relay), automatically switching to maximum or different set ventilation intensity the humidity level desired by the user will be maintained. Ventilation on demand when the motion sensor is connected to the control contacts, ventilation will be adjusted according to the demand, i.e. if people are indoors, ventilation will be carried out according to the set OVR intensity and if there s nobody in the room - the unit will operate according to the main user intensity, for example, the minimum. Ventilation with additional air extraction connection of an additional extracting device, for example, a kitchen hood or other extraction device without a separate fan, is intended, thus the air extraction is carried out by the unit itself. fter the activation of the function the supply and exhaust air fans start operating at the maximum intensity. Negative pressure compensation intended for the systems where air extraction can be carried out in a separate air extraction fan. Thus, for the compensation of negative pressure in a room, the OVR function can be activated by the separate control contacts. fter the activation of the function the exhaust air fans start operating at the maximum intensity and the exhaust air fan goes off. 6 U MLV reserves the right to introduce changes of parameters and sizes in the process of improvement of the air handling units.

29 ccessories Komfovent omekt utomatic accessories Komfovent kitchen hoods Painted or stainless steel versions Panel filters Timer for weekly programming (with control panel) Pressure switch Pa With OVR function Hot water duct heaters H Hot water heater regulation box vailable for all omekt units where hot water duct heater is used Movement detector With OVR function ir dampers with actuators Humidistat With OVR function Outdoor grill (for air supply/extraction) ir distribution box OS Only for unit REGO 00VE for horizontal connection of ducts detector o With OVR function Ordering key HU type REGO, REU Unit size Version: H - horizontal, V - vertical, P - false-ceiling ir heater: W - water, E - electric, F - counter cross-flow plate heat exchanger y-pass damper Inspection side: R - right, L - left ontroller type, PLUS Ordering example: REU 500PEF--R- PLUS XXXX XXX X X - X - X - X U MLV reserves the right to introduce changes of parameters and sizes in the process of improvement of the air handling units. 7

30 KOMFOVENT OMEKT unit in the ventilation system F 6 1 or E Ventilation system s elements 1 Unit OMEKT REGO 00VE Painted front panel, stainless steel panel is optional Kitchen hood (can be enclosed according to a customer s request, possible connection of other extraction devices) Remote control panel or touch sensitive PLUS 5 Grille 6 iffuser 7 Return valve 8 Outdoor grill (for air supply/extraction) 9 amper with actuator 10 Insulated duct 11 Regulating damper 1 Silencer Outdoor intake Supply air Extract indoor Exhaust air Extracted air from the kitchen E (by-pass damper extraction without heat recovery) F dditional extraction (by-pass damper extraction without heat recovery) 8 U MLV reserves the right to introduce changes of parameters and sizes in the process of improvement of the air handling units.

31

32 Komfovent producer: U malva, Ozo str. 10, LT-0800 Vilnius, Lithuania info@komfovent.com 01

DOMEKT. Heat Recovery Air Handling Units

DOMEKT. Heat Recovery Air Handling Units Heat Recovery ir Handling Units OMKT Heat Recovery ir Handling Units OMKT KOMFOVNT OMKT air handling units Komfovent air handling units are made to create healthy indoor climate and ensure efficient energy

More information

DOMEKT. Residential ventilation units

DOMEKT. Residential ventilation units OMEKT Residential ventilation units OMEKT Komfovent OMEKT OMEKT air handling units (HU) are designed for the ventilation of residential premises. OMEKT is a standardized series of the air handling units

More information

KOMPAKT. Air Handling Units

KOMPAKT. Air Handling Units ir Handling Units KOMPKT escription of Komfovent kompakt units 2 The new development in KOMPKT REGO range 3 Reasons to choose Komfovent kompakt units 4 ontrol System 6 KOMFOVENT KOMPKT REGO 10 Rotary

More information

DOMEKT. Residential ventilation air handling units

DOMEKT. Residential ventilation air handling units Residential ventilation air handling units DOMEKT Efficient heat recovery till 92% Low energy consumption Silent operation Integrated automatic control Healthy indoor climate and energy saving We spend

More information

VERSO Air Handling Units

VERSO Air Handling Units VERSO Air Handling Units Energy efficient solutions for profitable indoor climate VERSO Air Handling Units VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P

More information

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h VENTILTION equipment VENTILTION equipment content OMEKT Residential ventilation units 1 000 m³/h 15 VERSO Non residential ventilation units 0 34 000 m³/h 61 omekt R 17 omekt R V 19 omekt R 2 F New automatic

More information

AHU N : Range: VERSO VERSO. Heat Recovery Air Handling Units. Plug & Play Energy Saving Smart Design Reliable & Safe

AHU N : Range: VERSO VERSO. Heat Recovery Air Handling Units. Plug & Play Energy Saving Smart Design Reliable & Safe HU N : 07.09.356 Range: VERSO Heat Recovery ir Handling Units VERSO Plug & Play Energy Saving Smart esign Reliable & Safe VERSO ir Handling Units VERSO-S air supply units VERSO-R air handling units with

More information

17 Domekt R. Units with a rotary heat exchanger. Domekt RHP Units with a rotary heat exchanger and an integrated heat pump.

17 Domekt R. Units with a rotary heat exchanger. Domekt RHP Units with a rotary heat exchanger and an integrated heat pump. VENTILTION equipment VENTILTION equipment SUMMRY Komfovent range Komfovent air handling units create healthy indoor climate ensuring an efficient energy saving. The designed products meet a high quality

More information

DOMEKT Residential ventilation units

DOMEKT Residential ventilation units VENTILTION equipment Komfovent equipment SUMMRY Komfovent range Komfovent air handling units create healthy indoor climate ensuring an efficient energy saving. The designed products meet a high quality

More information

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation Air handling units KLASIK Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation KLASIK air handling units Customer oriented and unique

More information

VERSO DOMEKT. Residential ventilation units m³/h. Commercial ventilation units m³/h

VERSO DOMEKT. Residential ventilation units m³/h. Commercial ventilation units m³/h VENTILTION equipment VENTILTION equipment content OMEKT Residential ventilation units 1 000 m³/h 12 VERSO ommercial ventilation units 1000 40 000 m³/h 42 omekt R 14 omekt R V 16 omekt R 2 F 17 omekt R

More information

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation Air handling units KLASIK Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation KLASIK air handling units Customer oriented and unique

More information

VERSO Air Handling Units

VERSO Air Handling Units Energy efficient solutions for profitable indoor climate VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P air handling units equipped with recuperation system

More information

Elektros montavimo ir eksploatavimo instrukcija 2 Electrical installation and Operation Manual 18 Инструкция по электромонтажу и эксплуатации 34

Elektros montavimo ir eksploatavimo instrukcija 2 Electrical installation and Operation Manual 18 Инструкция по электромонтажу и эксплуатации 34 domekt rego / recu LT RU Elektros montavimo ir eksploatavimo instrukcija 2 Electrical installation and Operation Manual 18 Инструкция по электромонтажу и эксплуатации 34 Content 1. ELECTRICAL INSTALLATION

More information

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h VENTILTION equipment VENTILTION equipment content OMEKT Residential ventilation units 50 1 000 m³/h 15 VERSO Non residential ventilation units 1000 34 000 m³/h 61 omekt R 17 omekt R 200 V 19 omekt R 250

More information

Page 2 of 16. DOMEKT price-list PRICE-LIST Prices in POUND STERLING excluding VAT. Prices are valid for year 2018.

Page 2 of 16. DOMEKT price-list PRICE-LIST Prices in POUND STERLING excluding VAT. Prices are valid for year 2018. Domekt Units PRICE GUIDE 2018 price-list 2018 PRICE-LIST air handling units are designed for the ventilation of residential premise. series offers the standardized range of air handling units with heat

More information

Domekt R. Air handling units with a rotary heat exchanger. Operating capacity ranges from 50 to 950 m 3 /h. Advantages of Domekt R units

Domekt R. Air handling units with a rotary heat exchanger. Operating capacity ranges from 50 to 950 m 3 /h. Advantages of Domekt R units www.aeria-france.fr 3/11/216 omekt R ir handling units with a rotary heat exchanger. Operating capacity ranges from to 9 m 3. Standard sizes of omekt R units ir flow, m³/s,3,6,8,11,14,17,19,22,25,28 9

More information

VERSO. Commercial ventilation units 01/03/ Tél

VERSO. Commercial ventilation units 01/03/ Tél VERSO ommercial ventilation units istribué par ERI : contact@aeria-france.fr KOMFOVENT fabriqué par : U MLV www.komfovent.com SOUS RÉSERVE E MOIFITION SNS PRÉVIS 1/3/218 www.aeria-france.fr Tél 2 51 13

More information

AHU N : Range: VERSO VERSO. Air handling units. Plug & Play Energy Saving Smart Design Reliable & Safe

AHU N : Range: VERSO VERSO. Air handling units. Plug & Play Energy Saving Smart Design Reliable & Safe HU N : 07.09.356 Range: VERSO ir handling units VERSO Plug & Play Energy Saving Smart esign Reliable & Safe VERSO ir Handling Units VERSO-S air supply units VERSO-R air handling units with a rotary heat

More information

DOMEKT ReGO 400VE(W)-B Series Air Handling Units Installation and Maintenance Service Manual

DOMEKT ReGO 400VE(W)-B Series Air Handling Units Installation and Maintenance Service Manual DOMEKT ReGO 400VE(W)-B Series Air Handling Units EN Content Safety Requirements...3 Transportation...3 Brief Description of the Unit...5 Installation...6 Maintenance...11 Technical Information......13

More information

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION Swegon CASA W130 Ventilation unit with counter-flow plate heat exchanger Ventilation unit for residential houses under 250 m². The unit has counter-flow plate heat exchanger. Suitable also for renovation

More information

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25 Residential Heat Recovery Ventilation REHVA European Guidebook No 25 REHVA European Guidebook No 25 2 Limited to mechanical supply and exhaust ventilation Targeted to engineers, HVAC consultants and contractors

More information

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h VENTILATION equipment VENTILATION equipment content DOMEKT Residential ventilation units 50 1 000 m³/h 15 VERSO Non residential ventilation units 1000 34 000 m³/h 61 Domekt R 17 Domekt R 200 V 19 Domekt

More information

KOMFORT EC DB Suspended heat recovery air handling units

KOMFORT EC DB Suspended heat recovery air handling units 2018 AIR HANDLING UNITS KOMFORT EC DB Suspended heat recovery air handling units Features Air handling units for efficient supply and exhaust ventilation in flats, houses, cottages and other buildings.

More information

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning AIR HANDLING UNITS WITH HEAT RECOVERY Series VENTS enthalpy membrane in the warm season. This allows for a considerable reduction of the supply air temperature and humidity which, in turn, reduces the

More information

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 % Single-room heat recovery unit Air flow up to 59 CFM Heat recovery efficiency up to 96 % 2018 SINGLE-ROOM HEAT RECOVERY UNITS Features Efficient solution for supply and exhaust ventilation of enclosed

More information

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans! AIR HANDLING UNITS RIS P EKO 3.0 1 2 3 4 fans! Efficient EC E f f i c i e n c y up to 94%! E x t r e m e l y low height! New range - 5 sizes, 20 models! Contents Basic features 4 RIS P EKO 3.0 full range

More information

Specification data Topvex. Rotating or Cross flow heat exchanger.

Specification data Topvex. Rotating or Cross flow heat exchanger. Specification data Topvex Rotating or ross flow heat exchanger www.systemair.com Topvex Topvex SR, TR, SX and TX is a series of efficient ventilation units designed for offices, shops, schools, daycare

More information

Series VENTS VUT R WH ЕС

Series VENTS VUT R WH ЕС AIR HANDLING UNITS WITH HEAT RECOVERY Series VENTS EH ЕС Series VENTS WH ЕС Air handling units with the air capacity up to 1500 m 3 /h in soundand heat-insulated casing with integrated electric heater.

More information

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units. AIR HANDLING UNITS WITH HEAT RECOVERY Series VUT PE EC Series SAS908 control panel SAS908 control panel Ceiling mounted energy saving Air Handling Units (AHU) with the air capacity up to 4000 m 3 /h and

More information

Energy efficient ventilation equipment

Energy efficient ventilation equipment Energy efficient ventilation equipment Komfovent Energy Efficient KOMFOVENT is a trademark for ventilation products produced by the company AMALVA. KOMFOVENT stands for comfort, healthy indoor climate,

More information

DOMEKT ReCU 400VE(W)CF-EC-C4 Series Air Handling Units Installation and Maintenance Service Manual

DOMEKT ReCU 400VE(W)CF-EC-C4 Series Air Handling Units Installation and Maintenance Service Manual DOMEKT ReCU 400VE(W)CF-EC-C4 Series Air Handling Units Installation and Maintenance Service Manual EN Content Safety Requirements...3 Transportation...3 Brief Description of the Unit...5 Installation...6

More information

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION Swegon CASA R120 Ventilation unit with rotary heat exchanger Ventilation unit for residential houses, multi-storey buidings and holiday cottages under 230 m 2. The unit is equipped with rotary heat exchanger.

More information

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h PRODUCT DATA COMFORT 40 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 40 m /h COMFORT 40 Product description The Comfort 40 is an energy-efficient ventilation

More information

WORLD VENTILATION LEADER SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS

WORLD VENTILATION LEADER   SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS WORLD VENTILATION LEADER IO EM.COM SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS VENTS reserves the rights to modify any of its products featuers, designs, components and specifications

More information

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 % FRESHBOX 100 Single-room heat recovery unit Air capacity up to 100 m³/h Heat recovery efficiency up to 96 % FRESHBOX 100 CONTENTS FRESHBOX 100 FEATURES 3 DESIGN 4 OPERATING PRINCIPLE 6 CONTROL 6 APPLICATION

More information

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S Heat and Energy Recovery Ventilators 2018 AIR HANDLING UNITS 2 CONTENT KOMFORT EC S5B270(-E) 4 KOMFORT EC D5B1(-E) 8 KOMFORT EC S(B)(-E) 12 AIR HANDLING UNITS

More information

VERSO-P, VERSO-R Series Air Handling Units with C3 Control System Electrical Installation and Operation Manual

VERSO-P, VERSO-R Series Air Handling Units with C3 Control System Electrical Installation and Operation Manual VERSO-P, VERSO-R Series Air Handling Units with C3 Control System Electrical Installation and Operation Manual EN Table of Contents 1. INSTALLATION MANUAL...3 1.1. Air Handling Units Sections Connection...3

More information

Swegon CASA R85. Ventilation unit with rotary heat exchanger HOME VENTILATION

Swegon CASA R85. Ventilation unit with rotary heat exchanger HOME VENTILATION Swegon CASA R85 Ventilation unit with rotary heat exchanger Ventilation unit for residential houses, multi-storey buidings and holiday cottages under 170 m 2. The unit is equipped with rotary heat exchanger.

More information

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h PRODUCT DATA COMFORT 00 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 800 m /h COMFORT 00 Product description The Comfort 00 is an energy-efficient ventilation

More information

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses REC Temovex 4S-EC-RS Experts on indoor climate in low-energy houses RT 4S-EC-RS REC Temovex 4S-EC-RS ECO2 control system for low-energy and passive houses Comprises: - Air flow boost for warm and cold

More information

CASSETTE UNIT. Comfort Circle

CASSETTE UNIT. Comfort Circle CASSETTE UNIT Comfort Circle Comfort Circle cassette unit All-round comfort With today's energy prices, building owners are increasingly aware of the need for an efficient climate system to heat or cool

More information

Healthy, comfortable and energy-efficient ventilation

Healthy, comfortable and energy-efficient ventilation Healthy, comfortable and energy-efficient ventilation 300/400/450 180 Renovent Excellent 180, 300, 400 and 450 Silent and energy-efficient ventilation Central ventilation The Renovent Excellent is a mechanical

More information

AIR HANDLING UNITS ver B

AIR HANDLING UNITS ver B AIR HANDLING UNITS www.salda.lt 2013 ver B EC High efficiency air handling units are supplied with crosscounter flow plate heat exchangers. AHU is used for ventilation of houses and other heated areas.

More information

VEX100 series Air handling units with cross-flow heat exchanger

VEX100 series Air handling units with cross-flow heat exchanger Product information - Version 6 VEX100 series Air handling units with cross-flow heat exchanger VEX140: 400-2200 m 3 /h VEX150: 700-3600 m 3 /h VEX160: 1100-5000 m 3 /h VEX170: 1400-8400 m 3 /h Contents

More information

Healthy, comfortable and energy-efficient ventilation

Healthy, comfortable and energy-efficient ventilation Healthy, comfortable and energy-efficient ventilation partner Renovent Excellent 180, 300 and 400 Silent and energy-efficient ventilation 300/400 180 Central ventilation The Renovent Excellent is a mechanical

More information

Energy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1)

Energy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1) c a i r c im M Si l g n e r m o o ai a h r r ving i a a ze h s gy s t si e Fr e r p a c En m Co a r th i y w r t s ov e i un rec g t n li ea d n h in t e til oun a rs m ise e V sy no Ea w Lo g Industrial

More information

EASYAIR COMPACT DEVICE THE EASY WAY OF AIR HANDLING.

EASYAIR COMPACT DEVICE THE EASY WAY OF AIR HANDLING. EASYAIR COMPACT DEVICE THE EASY WAY OF AIR HANDLING. EASYAIR THE EASY WAY OF AIR HANDLING Independently VDI 6022 tested and certified down to the last detail The new generation of EASYAIR compact devices

More information

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction Air Comfort Air Treatment Energy Recovery eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction eco PREMIUM - Technical Instruction REDA 2 Contents Description Applications... 3 Quality & environment...

More information

VR 400/700 DCV/DC. Good ventilation For dwellings, smaller offices and business premises. com

VR 400/700 DCV/DC. Good ventilation For dwellings, smaller offices and business premises.   com VR 400/700 V/ Good ventilation or dwellings, smaller offices and business premises www.systemair. com Ventilation has one main aim. It should take away the consumed air that contains all the pollution

More information

Controlled mechanical ventilation GB 03

Controlled mechanical ventilation GB 03 RECUPER SLIM 2018 Controlled mechanical ventilation GB 03 ir conditioning Systems to install Recover... your wellbeing The home is a precious asset where we all spend a major time of your life. So it s

More information

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models. AIR HANDLING UNITS WITH HEAT RECOVERY Series Series VUT 350 PE EC VUT 600 PE EC VUT 1000 PE EC VUT 2000 PE EC VUT 3000 PE EC VUT 600 PW EC VUT 1000 PW EC VUT 2000 PW EC VUT 3000 PW EC Ceiling mounted air

More information

Home Solutions for Residential Ventilation

Home Solutions for Residential Ventilation Fans ir Handling Units ir Distribution Products Fire Safety ir Conditioning ir Curtains and Heating Products Tunnel Fans Home Solutions for Residential Ventilation Technical specification for SVE units

More information

Heat Recovery Unit HERU. web-version

Heat Recovery Unit HERU. web-version Heat Recovery Unit HERU web-version HERU 50 and 75 Heat recovery unit HERU is designed to suit places like houses, offices and other buildings where there is a big demand for high temperature efficiency,

More information

SINGLE-ROOM VENTILATION. for schools and public spaces

SINGLE-ROOM VENTILATION. for schools and public spaces SINGLE-ROOM VENTILATION for schools and public spaces Industrial and commercial ventilation (Catalogue no. 1) Industrial and commercial ventilation components - fans for round and rectangular ducts, sound-insulated,

More information

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation NUAIRE MVHR and Opposite Handed version ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due to its intelligent

More information

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS Compact heat recovery unit with high efficiency counter-flow heat exchanger in 5 sizes from 580 m3/h to 3.650 m3/h. The casing is made from aluminium profile

More information

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9 ERV/ HRV CONTENTS Horizontal rotor heat recovery ventilation unit RH 5 Vertical rotor heat recovery ventilation unit RV 9 Suspended plate heat recovery ventilation unit CFP Horizontal plate heat recovery

More information

TSEK VHR EC HEAT RECOVERY UNITS

TSEK VHR EC HEAT RECOVERY UNITS TSEK EC HEAT RECOVERY UNITS TS EN ISO 9001:2008 SN: 01 100 901925 General Information TSEK VENCO Heat Recovery Ventilation Units () are designed for saving energy and also improving indoor air quality.

More information

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses NEW! REC Temovex Blue 4 Experts on indoor climate in low-energy houses REC Temovex Blue 4 Third generation of our Temovex units! - Dual counterflow heat exchangers with over 9% efficiency * - SFP < 1,

More information

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h PRODUCT DATA COMFORT 5000 BY NILAN Ventilation & passive heat recovery Commercial Passive heat recovery Ventilation < 5300 m 3 /h COMFORT 5000 The Comfort 5000 is a ventilation unit suitable for central

More information

OVERVIEW and SYSTEM GUIDE. Swegon CASA. Residential ventilation for optimal operating economy and the greatest comfort.

OVERVIEW and SYSTEM GUIDE. Swegon CASA. Residential ventilation for optimal operating economy and the greatest comfort. OVERVIEW and SYSTEM GUIDE Swegon CASA Residential ventilation for optimal operating economy and the greatest comfort. www.swegon.com Swegon your system supplier Supply air diffuser Vapour barrier for duct

More information

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions) NUAIRE MVHR (including opposite handed versions) ACHIEVES 100% DUTY IN BYPASS MODE and MRXBOXAB- ECO-LP1-OH are specically designed for apartment applications where space is a premium. The new MRXBOX95-LP1

More information

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY Product Overview www.orcaenergy.eu MAXI Device for heat recovery MAXI is designed to provide permanent controlled air exchange by means of mechanical ventilation

More information

Flexit air handling units C2 and UNI 2, 3,4

Flexit air handling units C2 and UNI 2, 3,4 Flexit handling units C2 and UNI 2, 3,4 energy efficient ventilation for a healthy indoor environment A FOR A HEALTHY INDOOR ENVIRONMENT Energy-efficient ventilation Flexit C2 and UNI 2, 3, 4 The handling

More information

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models. AIR HANDLING UNITS WITH HEAT RECOVERY Series Series VUT 350 PE EC VUT 600 PE EC VUT 1000 PE EC VUT 2000 PE EC VUT 3000 PE EC VUT 600 PW EC VUT 1000 PW EC VUT 2000 PW EC VUT 3000 PW EC Ceiling mounted air

More information

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h PRODUCT DATA COMFORT 300 TOP BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 325 m 3 /h COMFORT 300 TOP Product description The Comfort 300 Top is an energy-efficient

More information

Plus Perimeter Aspiration Timer Remote control predisposition

Plus Perimeter Aspiration Timer Remote control predisposition Island Plus Perimeter Aspiration Timer Remote control predisposition Features Installation Finish Controls N. Motors Portata Max Recycling Max Noise Level Min Noise Level Total Absorption Dimensions Lighting

More information

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h PRODUCT DATA COMFORT 450 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 450 m 3 /h COMFORT 450 Product description The Comfort 450 is an energy-efficient ventilation

More information

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery. PRODUCT DATA COMBI 300 POLAR BY NILAN Ventilation with passive & active heat recovery Domestic Passive heat recovery Active heat recovery Ventilation < 350 m 3 /h Comfort heating Comfort cooling COMBI

More information

Flexit air handling units UNI 2, 3 og 4

Flexit air handling units UNI 2, 3 og 4 Flexit handling units UNI 2, 3 og 4 energy efficient ventilation for a healthy indoor environment FOR A HEALTHY INDOOR ENVIRONMENT Energy-efficient ventilation Flexit UNI 2, 3 and 4 The handling units

More information

Heat recovery unit RDKS

Heat recovery unit RDKS Heat recovery unit RDKS Heat recovery unit RDAS is based on our RDAR unit and develops this further. The unit has a rotary heat exchanger with stepless speed control. This allows for very precise temperature

More information

MRXBOXAB-ECO3 MRXBOX-ECO3

MRXBOXAB-ECO3 MRXBOX-ECO3 NUAIRE MVHR MRXBOX-ECO3 and Opposite Handed versions ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due

More information

MRXBOXAB-ECO2 MRXBOX-ECO2

MRXBOXAB-ECO2 MRXBOX-ECO2 NUAIRE MVHR MRXBOX-ECO2 and Opposite Handed versions ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due

More information

FlowGrid for Axial and Centrifugal Fans

FlowGrid for Axial and Centrifugal Fans FlowGrid for xial and Centrifugal Fans Less noise better quality of life. The engineer s choice Noise disturbances Cause and solution Innovating for people Situation Excess noise is the result of the inflow

More information

DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION

DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION 2 AERECO DX system DX SYSTEM A COMPLETELY NEW HEAT RECOVERY VENTILATION RANGE With the experience of a very innovative room-by-room demand

More information

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT AIR TREATMENT ReCOOLER HP ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT Energy efficiency the essence of our solutions All our research, development

More information

Domestic fans. Circular duct fans 1. Rectangular duct fans 2. Roof fans 3. Axial fans 4. Smoke evacuation fans 5.

Domestic fans. Circular duct fans 1. Rectangular duct fans 2. Roof fans 3. Axial fans 4. Smoke evacuation fans 5. Domestic fans Circular duct fans Rectangular duct fans Roof fans xial fans Smoke evacuation fans TEX rated fans Corrosion resistant fans Domestic fans ccessories Wiring diagrams 0 Index Content Centrifugal

More information

VALLOX VENTILATION PRICELIST 2018

VALLOX VENTILATION PRICELIST 2018 VALLOX VENTILATION PRICELIST 2018 1.1.2018 VENTILATION SYSTEM YOUR BEST LIFE INSURANCE Good ventilation is an important investment in the health of the house and its inhabitants, and also affects the lifespan

More information

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h PRODUCT DATA COMFORT 00 BY NILAN Ventilation & passive heat recovery Commercial Passive heat recovery Ventilation < 00 m /h COMFORT 00 The Comfort 00 is a ventilation unit suitable for central ventilation

More information

TopMaster Air Handling unit. Technical data

TopMaster Air Handling unit. Technical data Technical data Contents Page Description of the unit... 3 Design... 4 Technical data Size 030... 5 Size 0... 6 Accessories... 7 Controls... 9 Control functions... 10 Order codes... 11 Fläkt Woods 8180

More information

RIS V EKO A1/L2 RIS 700 V E L EKO 3.0 AIR HANDLING UNITS. Application

RIS V EKO A1/L2 RIS 700 V E L EKO 3.0 AIR HANDLING UNITS. Application EC A1/L2 7 1 19 2 75 Application Ventilation of houses, offices or other heated premises (classrooms, apartments, conference rooms, etc.) Description RIS V EKO 3. is a range of heat recovery units with

More information

Gas heaters and convectors ROBUR

Gas heaters and convectors ROBUR Gas heaters and convectors ROBUR Table of Contents Robur M general characteristic...3 Robur M dimensions...3 Robur M construction...4 Robur M technical data...5 Robur M installation...6 Robur M accessories...7

More information

RHC GAS FIRED HEATING COILS

RHC GAS FIRED HEATING COILS CI/SfB 56.83 X RHC GS FIRED HETING COILS RHC GS FIRED REZNOR HETING COILS Introduction Reznor gas fired heating coils are designed for inclusion in air handling units to provide a high efficiency gas fired

More information

Technical Information HXV - HRV Ventilation

Technical Information HXV - HRV Ventilation Technical Information HXV - HRV Ventilation General description Technical data Accessories VENTILATION HXV 5 1 General description 1.01-1.02 2 Technical data 2.01-2.02 3 Accessories 3.01-3.03 HRV 5 4 General

More information

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini... Contents How to choose Recovery Ventilation type?............................................3 How do HRV, ERV and TRV Systems work?............................................4 Types of installations..............................................................5

More information

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE NEW ECO RANGE MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) Mechanical Ventilation with Heat Recovery Proud to Build British u Nuaire is a world leader in the design and manufacture of fans and ventilation

More information

DEHUMIDIFIERS & VENTILATORS

DEHUMIDIFIERS & VENTILATORS 2015/2016 DEHUMIDIFIERS & VENTILATORS MCS GROUP www.mcsworld.com I CHOOSE MASTER DEHUMIDIFIERS. WHY? SAVE TIME dehumidifiers speed up many renovation and construction works REDUCE THE INVESTMENT COSTS

More information

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater SUPPLY UNITS Series VENTS PA E Series VENTS PA W A13 control panel A13 control panel Suspended air supply units with the air capacity up to 3350 m 3 /h in the sound- and heat-insulated casing with the

More information

EC A1/L2 RIRS V EKO AIR HANDLING UNITS

EC A1/L2 RIRS V EKO AIR HANDLING UNITS EC A1/L2 Application Description Ventilation of houses, small public buildings, offices or other heated premises (classrooms, apartments, conference rooms, etc.). RIRS V EKO 3.0 is a range of heat recovery

More information

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size) we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size) www.blowtech.in we make air move Blowtech Air Devices Pvt. Ltd. was founded in 1988 and quickly established

More information

PRODUCT DATA COMFORT 302 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 345 m 3 /h

PRODUCT DATA COMFORT 302 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 345 m 3 /h PRODUCT DATA COMFORT 302 TOP BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 345 m 3 /h COMFORT 302 TOP Product description The Comfort 302 Top is an energy efficient

More information

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution use Air flow rate: 500 to 8500 m 3 /h is a PLUG & PLAY dual-flow ventilation unit equipped with a highly

More information

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h VENTILATION equipment VENTILATION equipment content DOMEKT Residential ventilation units 50 1 000 m³/h 15 VERSO Non residential ventilation units 1000 34 000 m³/h 61 Domekt R 17 Domekt R 200 V 19 Domekt

More information

CONTENT: VEX308 Decentralised ventilation VEX308

CONTENT: VEX308 Decentralised ventilation VEX308 CONTENT: VEX308 Decentralised ventilation VEX308 VEX308 Decentralised ventilation Download all product data on VEX308 General VEX308 - decentralised ventilation for schools, institutions and offices A

More information

Roof top SPACE RPC 450Z R407C M011

Roof top SPACE RPC 450Z R407C M011 Roof top SPACE RPC 450Z R407C M011 Page : 1 / 5 Independant roof mounted unit, cooling only, ready to be installed, designed for air conditioning of large volumes for industrial or commercial use. As per

More information

Suxess Compact Top HEALTHY INDOOR ENVIRONMENT WITH ENERGY EFFICIENT VENTILATION

Suxess Compact Top HEALTHY INDOOR ENVIRONMENT WITH ENERGY EFFICIENT VENTILATION Suxess Compact Top HEALTHY INDOOR ENVIRONMENT WITH ENERGY EFFICIENT VENTILATION Quality and performance with skills and tradition Suxess is based in Enköping, Sweden, where we both develop and produce

More information

Breathe Fresh Air at Home

Breathe Fresh Air at Home Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans Breathe Fresh Air at Home Residential Ventilation 2 Category name / Registername

More information

PRODUCT DATA COMPACT S BY NILAN. Sanitary hot water production. Passive heat recovery. Comfort heating. Ventilation < 375 m 3 /h. Active heat recovery

PRODUCT DATA COMPACT S BY NILAN. Sanitary hot water production. Passive heat recovery. Comfort heating. Ventilation < 375 m 3 /h. Active heat recovery PRODUCT DATA COMPACT S BY NILAN Domestic Passive heat recovery Active heat recovery Ventilation < 375 m 3 /h Comfort heating Comfort cooling Sanitary hot water production COMPACT S Product description

More information

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S USER S MANUAL Heat (Energy) Recovery Ventilator Vents Frigate HRV 120 S Vents Frigate ERV 120 S 2 Frigate HRV(ERV) 120 S CONTENT Introduction... 3 Application... 3 Delivery set... 3 Unit designation key...

More information