1 Heat Recovery ir Handling Units OMKT

2

3 Heat Recovery ir Handling Units OMKT

4 KOMFOVNT OMKT air handling units Komfovent air handling units are made to create healthy indoor climate and ensure efficient energy saving. Products are designed and produced in conformance with high quality and performance requirements. ll components and parts of the units are accurately selected and assembled to achieve the best results in operation. Reliability of the products is based on the deep attention to the details. Your family health protection Units efficiently clean the air from the particulates, allergens, dust and maintain healthy indoor climate. Reliable and durable ouble quality control system. ir handling units efficiency is measured in a new modern laboratory. Units are tested in the independent laboratories in Switzerland and Germany. ouble anticorrosive units casing protection. Wide range of air handling units We are offering an extremely wide range of air handling units in order to fulfil our customers needs. nergy efficient Silent operation. Reduces expenses for heating, saves electric energy. Thermal efficiency and energy saving of the heat exchangers of KOMFOVNT air handling units are up to 9%. Highly efficient (electronically commutated) fans use 0% less energy than (alternating current) fans with voltage control. The special control system designed by our qualified engineers contributes to saving energy. User friendly control system Modern and attractive control panels enable a customer to select the desirable functions, set and change parameters as well as observe the ventilation processes on L screen. KOMFOVNT OMKT air handling units are intended for residential premise ventilation within 0 m to 0 m. Two functions in one unit:. Ventilates premise: ensures balanced ventilation with heat recovery supplying fresh air and extracting the used one.. Possibility to connect a kitchen hood or any other extraction device. ir handling units with integrated automatic control are fully prepared for installation: just PLUG & PLY. wide range and extremely compact size of the units allow the customer to mount them not only in the new premise but also in the renovated ones.

5 Quick KOMFOVNT OMKT unit selection OMKT RGO air handling units with rotary heat exchanger 00V/VW* Vertical 00V/VW* Vertical 0V- Vertical Passive House 0P/PW* Suspended 00P/PW* Suspended 600H/HW* Horizontal Residential area m ~0 ~60 ~80 ~0 ~00 ~0 Supply and exhaust m /h air flow under pressure Pa Thermal efficiency of rotary heat exchanger % fan type OMKT RU air handling units with plate heat exchanger 00V/VW* Vertical 00V/VW* Vertical Passive House 0V/VW* Vertical 00P/PW* Suspended Residential area m ~0 ~80 ~80 ~0 Supply and exhaust m /h air flow under pressure Pa Thermal efficiency of plate heat exchanger % fan type Notes: electrical heater, W hot water heater * uct mounted water air heater must be ordered additionally to be installed in the duct. Precise selection quipment is selected by helpful and informative software, available to be downloaded to your P from our website: Technical data sheets present important technical parameters in desired working point of the selected unit: efficiency, SFP, acoustics and other required data.

6 n : Range: ROTOR Heat exchangers in KOMFOVNT air handling units Rotary heat exchanger 6,8,0 +,0 +,6 TST IN GRMNY n SWITZRLN The operating principle of the RGO air handling units with nonfreezing rotary heat exchanger Rotary heat exchangers work on the principle of heat recovery: rotating aluminium drum absorbs heat of the exhaust air and warms up the air supplied to the ventilated room. dvantages of the rotary heat exchanger: rotary heat exchanger allows to reduce energy consumption for warming up the supply air by approximately times, compact, non freezing in comparison with the cross flow plate heat exchangers, a share of the exhaust air moisture is transferred to the air supplied to the ventilated room, cools down the supply air in summer in a conditioned space, no need in drainage. ouble plate heat exchanger,0,8 +,0 +8, The operating principle of the RU air handling unit with cross flow plate heat exchanger The heat of the exhaust air is transferred to the supply air through aluminium plates of the heat exchanger. ir flows through the heat exchanger crosswise. Unit design prevents penetration of the exhaust air to the fresh air flow. ounterflow polystyrene plate heat exchanger,0 6,6 +9,8 + dvantages of the plate heat exchanger: in the process of ventilation the heat of the exhaust air is recovered to the supplied air, totally separated air flows, special solution of using double plate heat exchangers reduces the risk of frosting, defrosting process is controlled by automatics. ounterflow aluminium plate heat exchanger 6,6,0 +9,8 + Intermediate moisture removal not: thermal efficiency indicated for wet conditions. for dry conditions efficiency refer to the selection software.

7 Vertical unit OMKT RGO 00V Unit is specially designed to be integrated into the kitchen furniture over the cooker. Its extremely compact size gives us a perfect possibility of simple mounting in a new flat, renovated premise, etc. Unit is applicable to ventilate the premise up to 0 m. ir handling unit is fully prepared for exploitation. Integrated automatic control with the wall mounted panel which is handy and simple in use ensures the most economic unit functioning and necessary control. Unit RGO 00V performs two functions:. Ventilates premise: ensures balanced ventilation with heat recovery supplying fresh air and extracting the used one,. xtracts the used air through kitchen hood: during cooking a user switches on the hood and the air is extracted through the hood by the unit. Kitchen hood has a specially designed damper inside. The air flow through the hood is adjusted with it. not: There is no danger of rotary wheel greasing because air flows are not mixing in the unit when you are cooking! WHY? ecause when you are cooking you switch on a cooker hood and it opens an internal by-pass damper by this action. Used air from cooking and fumes is extracted by exhaust fan and directed to the by-pass, without getting into rotor. xtract air fan can be easily taken out for cleaning when it is needed. Operation principle: When kitchen hood is switched On When kitchen hood is switched Off xtract through kitchen hood

8 Vertical units OMKT RGO 00V Highly efficient rotary heat exchanger recovers up to 89% of heat. RGO 00V special design has a big advantage: user does not need to specify unit s inspection side. This unit is both right- and left- hand in one. front and back covering panels are easi ly removable this way, when installing it, the unit must be only turned around to get the required inspection side and ducts connection. Integrated automatic control with the wall mounted touch sensitive panel which is handy and simple in operation ensures the most economic unit functioning and necessary control. RGO 00V Shown as left 6 for some units right and left sides are mirrored, but in some units are rotated. hoose the right side of unit installation Shown as right 7 (x) f xplication f Rotary heat exchanger lectric air heater Supply air filter xhaust air filter Supply fan 6 xhaust fan 7 utomation control system dditional extraction connection (by pass extraction without heat recovery) Kitchen hood connection f (by pass extraction without heat recovery) 6

9 Technical information RGO 00V RGO 00VW* Supply voltage, V/Hz ~0 / 0 / phase Maximal operating current, Input fans power, W x 70 Heater capacity, kw 0.8. Unit size (height x width x depth), mm 6 x 600 x 0 uctwork connection, mm x filter for supply/exhaust air, mm 8 x 0 x 6-f7 Unit weight, kg Unit color RL 900 * for more detailed information look at the hot water duct air heater H specification. Static pressure (Pa) RGO 00V performances ir volume flowrate (m /s) 0 0,0 0,0 0,06 0, SFP 00 SFP 0, SFP 0, 0 Temperature efficiency η t (%) Temperature efficiency % pplication: RH 8% outdoor RH % indoor kw ir volume flowrate (m /h),,, nergy recovery (kw) ir volume flowrate (m /h) P[kW] = SFP[kW (m s)] V[m s]. SFP is shown for one fan. Performance data: filter f7. To calculate the power consumption for fan use formula: P = SFP V; where SFP kw (m s) and V m s. RGO 00V acoustic data -weighted sound power levels L w, d(). Operation point: 0 m /h (9 l/s), 00 Pa. Octave band mid-frequency, Hz dditional inlet Kitchen hood inlet asing Total , , , , , , 0 8 8, The sound data table indicates the sound power level L w which should not be confused with the sound pressure level L p. -weighted sound pressure levels L p, d(), 0 m normally isolated room, distance from casing m. Surroundings ,7 7

10 Vertical units OMKT RGO 00V xtremely compact unit in size and high energy efficient. Highly efficient rotary heat exchanger recovers up to 90% of heat. Unit compact size and high efficiency offer the best choice to ensure healthy microclimate in your apartments or small houses. Unit is applicable to ventilate the premise up to 60 m. Unit is designed to ensure ventilation in the premise and may be connected with a kitchen hood via an additional duct. ny exhaust air diffuser may be connected instead of a kitchen hood to by pass duct connection (to extract air from bathroom, laundry, etc.). Integrated automatic control with the wall mounted touch sensitive panel, which is handy and simple in operation ensures the most economic unit functioning and necessary control. RGO 00V Shown as left 7 6 Shown as right xplication Rotary heat exchanger lectric air heater Supply air filter xhaust air filter Supply fan 6 xhaust fan 7 utomation control system dditional extraction connection (by pass extraction without heat recovery) 8

11 Technical information RGO 00V RGO 00VW* Supply voltage, V/Hz ~0 / 0 / phase Maximal operating current, Input fans power, W x 70 Heater capacity, kw.0. Unit size (height x width x depth), mm uctwork connection, mm filter for supply/exhaust air, mm Unit weight, kg Unit color 7 x 600 x 9 x 60, x 0 x 0 x 6-f7 RL 900 * for more detailed information look at the hot water duct air heater H specification. Static pressure (Pa) RGO 00V performances ir volume flowrate (m /s) 0 0,0 0,0 0,06 0,08 00 SFP 0,7 0 SFP 0, 00 0 SFP 0, 00 SFP 0, 0 Temperature efficiency η t (%) Temperature efficiency % kw pplication: RH 8% outdoor RH % indoor ir volume flowrate (m /h) nergy recovery (kw) P[kW]= SFP[kW (m s)] V[m s]. SFP is shown for one fan. Performance data: filter F7. note: characteristics explanation is available on the page 7. ir volume flowrate (m /h) RGO 00V acoustic data -weighted sound power levels L w, d(). Operation point: 0 m /h (8 l/s), 00 Pa. Octave band mid-frequency, Hz dditional inlet asing Total , , , , , , The sound data table indicates the sound power level L w which should not be confused with the sound pressure level L p. -weighted sound pressure levels L p, d(), 0 m normally isolated room, distance from casing m. Surroundings , 9

12 Vertical units OMKT RGO 0V- xtremely compact unit in size and high energy efficient Highly efficient rotary heat exchanger recovers up to 8% of heat. Unit compact size and high efficiency offer the best choice to ensure healthy microclimate in your apartments or small houses. Unit is applicable to ventilate the premise up to 80 m. Unit is designed to ensure ventilation in the premise and may be connected with a kitchen hood via an additional duct. ny exhaust air diffuser may be connected instead of a kitchen hood to by pass duct connection (to extract air from bathroom, laundry, etc.). Integrated automatic control with the wall mounted touch sensitive panel which is handy and simple in operation ensures the most economic unit functioning and necessary control. RGO 0V- Shown as left 7 6 Shown as right xplication Rotary heat exchanger lectric air heater Supply air filter xhaust air filter Supply fan 6 xhaust fan 7 utomation control system dditional extraction connection (by pass extraction without heat recovery) 0

13 Technical information Supply voltage, V/Hz Maximal operating current, Input fans power, W Heater capacity, kw nergy recovery of rotary heat exchanger up to, kw Unit size (height x width x depth), mm uctwork connection, mm filter for supply/exhaust air, mm Unit weight, kg Unit color RGO 0V ~0 / 0 / phase. x.0 ~. 60 x 680 x x 60, x 70 x 0 x 6-f7 6 RL 900 RGO 0V performances Temperature efficiency ir volume flowrate (m /s) Static pressure (Pa) 0 0,0 0,06 0,09 0, 00 SFP, 0 00 SFP 0 SFP 0, SFP 0, 00 0 Temperature efficiency η t (%) % pplication: RH 8% outdoor RH % indoor kw ir volume flowrate (m /h) 6 nergy recovery (kw) P[kW]= SFP[kW (m s)] V[m s]. SFP is shown for one fan. Performance data: filter F7. note: characteristics explanation is available on the page 7. ir volume flowrate (m /h) RGO 0V acoustic data -weighted sound power levels L w, d(). Operation point: m /h (88 l/s), 00 Pa. Octave band mid-frequency, Hz dditional inlet asing Total , , , , , ,7 The sound data table indicates the sound power level L w which should not be confused with the sound pressure level L p. -weighted sound pressure levels L p, d(), 0 m normally isolated room, distance from casing m. Surroundings 8 8,8

14 False-ceiling units OMKT RGO 0P Unit s height is only 0 mm so it can be easily mounted in any convenient place. Rotary heat exchanger ensures high heat recovery and thermal efficiency up to 87%. Special unit s design with extremely low height allows us to mount it horizontally, hiding by false-ceiling or vertically near the wall. Unit RGO 0P may ventilate premise up to 0 m. It is intended for ventilation of flats, apartments, small houses, as well as classrooms, small offices and conference rooms. Integrated automatic control with the wall mounted touch sensitive panel which is handy and simple in operation ensures the most economic unit functioning and necessary control. RGO 0P Shown as right (x) Shown as left xplication Rotary heat exchanger lectric air heater Supply air filter xhaust air filter Supply fan 6 xhaust fan 7 utomation control system dditional extraction connection (by pass extraction without heat recovery)

15 Technical information RGO 0P RGO 0PW* Supply voltage, V/Hz ~0 / 0 / phase Maximal operating current,.70.6 Input fans power, W Heater capacity, kw Unit size (height x width x depth), mm uctwork connection, mm filter for supply/exhaust air, mm Unit weight, kg Unit color x x 0 x 790 x 60, x 78 x 8 x 6-f7 RL 900 * for more detailed information look at the hot water duct air heater H specification. Static pressure (Pa) RGO 0P performances ir volume flowrate (m /s) 0 0,0 0,0 0,06 0,08 0 SFP, 00 0 SFP 00 SFP 0,7 0 Temperature efficiency η t (%) Temperature efficiency % 7 0, pplication: RH 8% outdoor RH % indoor kw ir volume flowrate (m /h),,,, nergy recovery (kw) SFP 0, P[kW]= SFP[kW (m s)] V[m s]. SFP is shown for one fan. Performance data: filter F7. note: characteristics explanation is available on the page 7. ir volume flowrate (m /h) RGO 0P acoustic data -weighted sound power levels L w, d(). Operation point: 7 m /h (9 l/s), 00 Pa. Octave band mid-frequency, Hz dditional inlet asing Total , , , , , , The sound data table indicates the sound power level L w which should not be confused with the sound pressure level L p. -weighted sound pressure levels L p, d(), 0 m normally isolated room, distance from casing m. Surroundings ,

16 False-ceiling units OMKT RGO 00P Unit s height is only 0 mm. High thermal efficiency is reaching up to 88% because of two rotors used in the unit. Unit RGO 00P is applicable for the ventilation of premise up to 80 m area. It is intended for ventilation of apartments, small houses, conference rooms. In spite of low unit s height, thermal efficiency in RGO 00P reaches up to 88% because of two rotors used in the unit. y-pass or any other exhaust air diffuser may be connected instead of a kitchen hood to by pass duct connection (to extract air from bathroom, laundry, etc.). Integrated automatic control with the wall mounted touch sensitive panel which is handy and simple in operation ensures the most economic unit functioning and necessary control. RGO 00P Shown as right (x) Shown as left xplication Rotary heat exchanger lectric air heater Supply air filter xhaust air filter Supply fan 6 xhaust fan 7 utomation control system dditional extraction connection (by pass extraction without heat recovery)

17 Technical information RGO 00P RGO 00PW* Supply voltage, V/Hz ~0 / 0 / phase Maximal operating current, Input fans power, W x 6 Heater capacity, kw.0. Unit size (height x width x depth), mm uctwork connection, mm filter for supply/exhaust air, mm Unit weight, kg Unit color 0 x 60 x 0 x 00, x 78 x 8 x 6-f7 6 RL 900 * for more detailed information look at the hot water duct air heater H specification. RGO 00P performances Temperature efficiency ir volume flowrate (m /s) Static pressure (Pa) 0 0,0 0,0 0,06 0,08 0, 0, 0, 00 0 SFP, 00 SFP 0 SFP 0,7 00 SFP 0, 0 Temperature efficiency η t (%) % kw pplication: RH 8% outdoor RH % indoor ir volume flowrate (m /h) nergy recovery (kw) P[kW]= SFP[kW (m s)] V[m s]. SFP is shown for one fan. Performance data: filter F7. note: characteristics explanation is available on the page 7. ir volume flowrate (m /h) RGO 00P acoustic data -weighted sound power levels L w, d(). Operation point: 80 m /h (78 l/s), 00 Pa. Octave band mid-frequency, Hz dditional inlet asing Total , , , , , ,8 The sound data table indicates the sound power level L w which should not be confused with the sound pressure level L p. -weighted sound pressure levels L p, d(), 0 m normally isolated room, distance from casing m. Surroundings ,9

18 Horizontal units OMKT RGO 600H xtremely compact design with high efficiency up to 89%. Unit RGO 600H is applicable for the ventilation of premise up to 0 m and is intended for ventilation of big apartments, medium houses, conference rooms, etc. High efficiency unit with compact design can be easily installed in new premise as well as in renovated ones. The width of RGO 600H without side panels is only 70 mm. It is easy to carry such a unit into the attic through the narrow stairwell or other hard approachable places. The unit has an additional connection for air extraction from kitchen hood or other extraction device (to extract air from bathroom, laundry, etc.). Integrated automatic control with the wall mounted touch sensitive panel which is handy and simple in operation ensures the most economic unit functioning and necessary control. RGO 600H Shown as right (x) Shown as left xplication Rotary heat exchanger lectric air heater Supply air filter xhaust air filter Supply fan 6 xhaust fan 7 Power supply cable dditional extraction connection (by pass extraction without heat recovery) 6

19 Technical information RGO 600H RGO 600HW* Supply voltage, V/Hz ~0 / 0 / phase Maximal operating current, Input fans power, W x 6 Heater capacity, kw.0.0 Unit size (height x width x depth), mm uctwork connection, mm filter for supply/exhaust air, mm Unit weight, kg Unit color 600 x 0 x 70 x 00, x 7 x x 6-f7 90 RL 900 * for more detailed information look at the hot water duct air heater H specification. Static pressure (Pa) RGO 600H performances ir volume flowrate (m /s) 0 0,0 0,08 0, 0,6 00 SFP, 0 00 SFP 0 SFP 0,7 00 SFP 0, 0 Temperature efficiency η t (%) Temperature efficiency % kw pplication: RH 8% outdoor RH % indoor ir volume flowrate (m /h) nergy recovery (kw) ir volume flowrate (m /h) P[kW]= SFP[kW (m s)] V[m s]. SFP is shown for one fan. Performance data: filter F7. note: characteristics explanation is available on the page 7. RGO 600H acoustic data -weighted sound power levels L w, d(). Operation point: 0 m /h (7 l/s), 00 Pa. Octave band mid-frequency, Hz dditional inlet asing Total , , , , , , The sound data table indicates the sound power level L w which should not be confused with the sound pressure level L p. -weighted sound pressure levels L p, d(), 0 m normally isolated room, distance from casing m. Surroundings ,9 7

20 Vertical units OMKT RU 00V ouble plate heat exchanger with crosswise air flows ensures the heat recovery up to 86%. Unit RU 00V is developed and designed to create mechanical ventilation and heat recovery in flats, apartments or other residential premises up to 0 m. The supply and exhaust air flows are separated in the unit with plate heat exchanger, that is why heat from the foul air can be recovered as well. We can also recover the heat from the premise with a strong smell, e.g. from kitchen, bathroom, etc. The unit has an additional extraction connection for kitchen hood. Integrated automatic control with the wall mounted touch sensitive panel which is handy and simple in operation ensures the most economic unit functioning and necessary control. RU 00V Shown as right Special design of RU 00V allows the user to choose the needed inspection side (it is both left and right hand). The side panel of the units can be easily removed. fter the needed inspection side is chosen, the unit is turned around and the ducts are connected. Shown as left xplication ouble plate heat exchanger lectric air heater Supply air filter xhaust air filter Supply fan 6 xhaust fan 7 utomation control system 8 y-pass damper 9 rainage dditional extraction connection (by pass extraction without heat recovery) 8

21 Technical information RU 00V RU 00VW* Supply voltage, V/Hz ~0 / 0 / phase Maximal operating current, Input fans power, W Heater capacity, kw Unit size (height x width x depth), mm uctwork connection, mm filter for supply/exhaust air, mm Unit weight, kg Unit color x x 70 x 0 x 00 x 00 x 6-f7 RL 900 * for more detailed information look at the hot water duct air heater H specification. Static pressure (Pa) RU 00V performances ir volume flowrate (m /s) 0 0,0 0,0 0,06 0,08 00 SFP, 00 SFP 00 SFP 0,7 SFP 0, 00 Temperature efficiency η t (%) Temperature efficiency % pplication: RH 8% outdoor RH % indoor kw ir volume flowrate (m /h) nergy recovery (kw) ir volume flowrate (m /h) P[kW]= SFP[kW (m s)] V[m s]. SFP is shown for one fan. Performance data: filter F7. note: characteristics explanation is available on the page 7. RU 00V acoustic data -weighted sound power levels L w, d(). Operation point: 0 m /h (8 l/s), 00 Pa. Octave band mid-frequency, Hz dditional inlet asing Total , , , , 0 9 8, 7 6 6,9 The sound data table indicates the sound power level L w which should not be confused with the sound pressure level L p. -weighted sound pressure levels L p, d(), 0 m normally isolated room, distance from casing m. Surroundings 6,0 9

22 Vertical units OMKT RU 00V F nergy efficiency 8%. Unit is developed and designed to create mechanical ventilation and heat recovery in flats, apartments or other residential premise up to 0 m. High efficient plate heat exchangers and fans guarantee the most effective and economical unit operation: up to 8% of energy required for supplied air heating is recovered and used from the exhausted air. Integrated automatic control with the wall mounted touch sensitive panel which is handy and simple in operation ensures the most economic unit functioning and necessary control. RU 00V F Shown as right 0 Shown as left xplication ounterflow plate heat exchanger (aluminium) (x) lectric air heater Supply air filter xhaust air filter Supply fan 6 xhaust fan 7 utomation control system 8 y-pass damper 9 rainage

23 Technical information Supply voltage, V/Hz Maximal operating current, Input fans power, W Heater capacity, kw Unit size (height x width x depth), mm uctwork connection, mm filter for supply/exhaust air, mm Unit weight, kg Unit color RU 00VF RU 00VWF* ~0 / 0 / phase.8. x x 98 x 600 Ø 60 x 0 x 6-f7 RL 900 * for more detailed information look at the hot water duct air heater H specification. RU 00V F performances Temperature efficiency ir volume flowrate (m /s) Static pressure (Pa) 0 0,0 0,06 0,09 0, 00 SFP, SFP Temperature efficiency η t (%) % kw nergy recovery (kw) SFP 0,7 ir volume flowrate (m /h) 00 SFP 0, pplication: RH 8% outdoor RH % indoor ir volume flowrate (m /h) P[kW]= SFP[kW (m s)] V[m s]. SFP is shown for one fan. Performance data: filter F7. note: characteristics explanation is available on the page 7. RU 00V F acoustic data -weighted sound power levels L w, d(). Operation point: 80 m /h (78 l/s), 00 Pa. Octave band mid-frequency, Hz asing Total , , , , ,8 The sound data table indicates the sound power level L w which should not be confused with the sound pressure level L p. -weighted sound pressure levels L p, d(), 0 m normally isolated room, distance from casing m. Surroundings 0 8 9,6

24 Vertical units OMKT RU 0V ouble plate heat exchanger with crosswise air flows ensures the heat recovery up to 8%. Unit RU 0V is developed and designed to create mechanical ventilation and heat recovery in flats, apartments or other residential premises up to 80 m. The supply and exhaust air flows are separated in the unit with plate heat exchanger, that is why heat from the foul air can be recovered as well. We can also recover the heat from the premise with a strong smell, e.g. from kitchen, bathroom, etc. The unit has an additional extraction connection for kitchen hood. Integrated automatic control with the wall mounted touch sensitive panel which is handy and simple in operation ensures the most economic unit functioning and necessary control. RU 0V Shown as right Special design of RU 0V allows the user to choose the needed inspection side (it is both left and right hand). The side panel of the units can be easily removed. fter the needed inspection side is chosen, the unit is turned around and the ducts are connected. Shown as left xplication ouble plate heat exchanger lectric air heater Supply air filter xhaust air filter Supply fan 6 xhaust fan 7 utomation control system 0 8 y-pass damper 9 rainage dditional extraction connection (by pass extraction without heat recovery)

25 Technical information RU 0V RU 0VW* Supply voltage, V/Hz ~0 / 0 / phase Maximal operating current, Input fans power, W x 7 Heater capacity, kw.0. Unit size (height x width x depth), mm uctwork connection, mm filter for supply/exhaust air, mm Unit weight, kg Unit color 700 x 70 x 0 x 00 x 00 x 6-f7 RL 900 * for more detailed information look at the hot water duct air heater H specification. RU 0V performances Temperature efficiency Static pressure (Pa) ir volume flowrate (m /s) 0 0,0 0,08 0, 00 SFP, 0 SFP 00 SFP 0,7 0 SFP 0, 00 0 Temperature efficiency η t (%) % kw pplication: RH 8% outdoor RH % indoor ir volume flowrate (m /h) nergy recovery (kw) ir volume flowrate (m /h) P[kW]= SFP[kW (m s)] V[m s]. SFP is shown for one fan. Performance data: filter F7. note: characteristics explanation is available on the page 7. RU 0V acoustic data -weighted sound power levels L w, d(). Operation point: m /h (88 l/s), 00 Pa. Octave band mid-frequency, Hz dditional inlet asing Total , , , , , , The sound data table indicates the sound power level L w which should not be confused with the sound pressure level L p. -weighted sound pressure levels L p, d(), 0 m normally isolated room, distance from casing m. Surroundings 0 7 8,0

26 False-ceiling units OMKT RU 00P F nergy efficiency 9%. Unit is developed and designed to create mechanical ventilation and heat recovery in flats, apartments or other residential premise up to 00 m. High efficient plate heat exchangers and fans guarantee the most effective and economical unit operation: up to 9% of energy required for supplied air heating is recovered and used from the exhausted air. Integrated automatic control with the wall mounted touch sensitive panel which is handy and simple in operation ensures the most economic unit functioning and necessary control. RU 00P F Shown as left (x) Shown as right 6 xplication ounterflow plate heat exchanger (polystyrene) lectric air heater Supply air filter xhaust air filter Supply fan 6 xhaust fan 7 utomation control system 8 y-pass damper 9 rainage dditional extraction connection (by pass extraction without heat recovery)

27 Technical information RU 00PF RU 00PWF* Supply voltage, V/Hz ~0 / 0 / phase Maximal operating current, Input fans power, W x 6 Heater capacity, kw.0. Unit size (height x width x depth), mm uctwork connection, mm filter for supply/exhaust air, mm Unit weight, kg Unit color 90 x 00 x 80 Ø 00 0 x 00 x 6-f7 70 RL 900 * for more detailed information look at the hot water duct air heater H specification. Static pressure (Pa) RU 00P F performances ir volume flowrate (m /s) 0 0,0 0,08 0, 0,6 0, 00 0 SFP, 00 0 SFP 00 SFP 0, SFP 0, 0 Temperature efficiency η t (%) Temperature efficiency % pplication: RH 8% outdoor RH % indoor kw ir volume flowrate (m /h) nergy recovery (kw) P[kW]= SFP[kW (m s)] V[m s]. SFP is shown for one fan. Performance data: filter F7. note: characteristics explanation is available on the page 7. ir volume flowrate (m /h) RU 00P F acoustic data -weighted sound power levels L w, d(). Operation point: 0 m /h (97 l/s), 00 Pa. Octave band mid-frequency, Hz dditional inlet asing Total , , , , , ,9 The sound data table indicates the sound power level L w which should not be confused with the sound pressure level L p. -weighted sound pressure levels L p, d(), 0 m normally isolated room, distance from casing m. Surroundings ,

28 utomatic control KOMFOVNT OMKT control main functions: Measurements of the control panel 6 x 79 x 6 mm ontrol panel connecting cable (0 m) x 0, mm Unit operation mode selection: On/Off/uto; Setting of ventilation intensity level: %; Weekly schedule programming; Setting temperature in the control panel:...0 ; Setpoint sliding for the set period of time: +/ 9 ; Season setting: Summer/Winter; OVR function activation via external device; OVR activation by the control panel for set time period:...90 min.; Setting fans intensity level for OVR function: %; Language selection; Failures indication history: log with 0 events with time and date; Panel locking with PIN. ontrol OMKT units from any place in the world! Smart control using Komfovent Home mobile application Simple and easy control Indication of unit parameters Ventilation intensity control Supply air temperature adjustment not: air handling unit must be connected to wireless computer network or internet via PInG network module. onvenient management and control using web browser Remote control via a local computer network or the internet is realized by network module Ping. This module is provided with an integrated web server that allows you to control and monitor the HU s operation without any special software. Remote unit intensity control (OVR) OVR (eng. override ignore) function is intended for the remote unit s control with an external accessory device. fter this function is activated the current unit s mode becomes omissible and the unit starts working according to the newly set parameters. pplications of the OVR functions: Maintenance of O quantity in a room by adding a O sensor (with relay), at higher levels of O the main user-set ventilation rate will be switched to the maximum intensity until the room is ventilated, and then again will return to the user-defined intensity. Maintaining relative humidity in the room after contacting the external relative humidity sensor (with relay), automa tically switching to maximum or different set ventilation intensity the humidity level desired by the user will be maintained. Ventilation on demand when the motion sensor is connected to the control contacts, ventilation will be adjusted according to the demand, i.e. if people are indoors, ventilation will be carried out according to the set OVR intensity and if there s nobody in the room the unit will operate according to the main user intensity, for example, the minimum. Ventilation with additional air extraction connection of an additional extracting device, for example, a kitchen hood or other extraction device without a separate fan, is intended, thus the air extraction is carried out by the unit itself. fter the activation of the function the supply and exhaust air fans start operating at the maximum intensity. Negative pressure compensation intended for the systems where air extraction can be carried out in a separate air extraction fan. Thus, for the compensation of negative pressure in a room, the OVR function can be activated by the separate control contacts. fter the activation of the function the supply air fans start operating at the maximum intensity and the exhaust air fan goes off. 6

29 Installation of Komfovent omekt Vertical units False-ceiling units With directly integrated kitchen hood Komfovent (only for RGO 00V) With kitchen hood KOMFOVNT connected via duct With separately connected kitchen hood Komfovent With additionally connected extraction diffusers With separately connected additional extract air diffusers If a kitchen hood is not used, an extraction diffuser from the bathroom, laundry, or other premise can be connected to the unit as well. alanced ventilation system in the premise When the kitchen hood is switched on, the supply air flow in the unit increases and the exhaust one decreases automatically. This way we can feel the supply/exhaust air flows balance in the premise. note: Special units design with extremely low heights allows us to mount them horizontally, hiding by the false-ceiling or vertically on the wall. alanced ventilation system in the premise When the kitchen hood is switched on, the supply air flow in the unit increases and the exhaust one decreases automatically. This way we can feel the supply/exhaust air flows balance in the premise. important: OMKT equipment must be installed in heated premises. dditional extraction connection (by-pass extraction without heat recovery) 7

30 ccessories Unit in the ventilation system KOMfOVnT kitchen hoods Painted or stainless steel versions Hot water duct heaters H ir dampers with actuators Outdoor grill for air supply/ extraction 6 Panel filters f Hot water heater regulation box vailable for all omekt units where hot water duct heater is used ir distribution box OS Only for unit RGO 00V for horizontal connection of ducts Remote unit intensity control (OVR) Ventilation system s elements Unit OMKT RGO 00V Painted front panel, stainless steel panel is optional Kitchen hood (can be enclosed according to a customer s request, possible connection of other extraction devices) Remote touch sensitive control panel Grille 6 iffuser 7 Return valve 8 Outdoor grill (for air supply/extraction) 9 amper with actuator 0 Insulated duct Regulating damper Silencer dditional extraction connection (by pass extraction without heat recovery) f Kitchen hood connection (by pass extraction without heat recovery) ifferential pressure switch TV00 Motion detector PIR80 Wall mounted temperature sensor RTT Wall mounted humidity sensor RTH uct mounted humidity sensor TH Wall mounted O sensor RT uct mounted O sensor T Wall mounted air quality sensor RTQ Ordering key xample: HU type RGO, RU Unit size Version: H horizontal, V vertical, P false-ceiling ir heater: W water, electric F counter cross flow plate y-pass damper Inspection side: R right, L left ontroller type RU 00 P F - - R - xxxx xxx x x x - x - x - x uct mounted air quality sensor TQ 8

31 PLUS

32 Komfovent producer: U malva Ozo str. 0 LT-0800 Vilnius Lithuania info@komfovent.com 0

Heat Recovery Air Handling Units

Heat Recovery Air Handling Units Heat Recovery ir Handling Units OMEKT Heat recovery air handling Units OMEKT 1 KOMFOVENT OMEKT ir Handling Units Komfovent ir Handling units are made to create healthy indoor climate and ensure efficient

More information

DOMEKT. Residential ventilation units

DOMEKT. Residential ventilation units OMEKT Residential ventilation units OMEKT Komfovent OMEKT OMEKT air handling units (HU) are designed for the ventilation of residential premises. OMEKT is a standardized series of the air handling units

More information

DOMEKT. Residential ventilation air handling units

DOMEKT. Residential ventilation air handling units Residential ventilation air handling units DOMEKT Efficient heat recovery till 92% Low energy consumption Silent operation Integrated automatic control Healthy indoor climate and energy saving We spend

More information

KOMPAKT. Air Handling Units

KOMPAKT. Air Handling Units ir Handling Units KOMPKT escription of Komfovent kompakt units 2 The new development in KOMPKT REGO range 3 Reasons to choose Komfovent kompakt units 4 ontrol System 6 KOMFOVENT KOMPKT REGO 10 Rotary

More information

AHU N : Range: VERSO VERSO. Heat Recovery Air Handling Units. Plug & Play Energy Saving Smart Design Reliable & Safe

AHU N : Range: VERSO VERSO. Heat Recovery Air Handling Units. Plug & Play Energy Saving Smart Design Reliable & Safe HU N : 07.09.356 Range: VERSO Heat Recovery ir Handling Units VERSO Plug & Play Energy Saving Smart esign Reliable & Safe VERSO ir Handling Units VERSO-S air supply units VERSO-R air handling units with

More information

VERSO Air Handling Units

VERSO Air Handling Units VERSO Air Handling Units Energy efficient solutions for profitable indoor climate VERSO Air Handling Units VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P

More information

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h VENTILTION equipment VENTILTION equipment content OMEKT Residential ventilation units 1 000 m³/h 15 VERSO Non residential ventilation units 0 34 000 m³/h 61 omekt R 17 omekt R V 19 omekt R 2 F New automatic

More information

VERSO DOMEKT. Residential ventilation units m³/h. Commercial ventilation units m³/h

VERSO DOMEKT. Residential ventilation units m³/h. Commercial ventilation units m³/h VENTILTION equipment VENTILTION equipment content OMEKT Residential ventilation units 1 000 m³/h 12 VERSO ommercial ventilation units 1000 40 000 m³/h 42 omekt R 14 omekt R V 16 omekt R 2 F 17 omekt R

More information

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation Air handling units KLASIK Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation KLASIK air handling units Customer oriented and unique

More information

Domekt R. Air handling units with a rotary heat exchanger. Operating capacity ranges from 50 to 950 m 3 /h. Advantages of Domekt R units

Domekt R. Air handling units with a rotary heat exchanger. Operating capacity ranges from 50 to 950 m 3 /h. Advantages of Domekt R units www.aeria-france.fr 3/11/216 omekt R ir handling units with a rotary heat exchanger. Operating capacity ranges from to 9 m 3. Standard sizes of omekt R units ir flow, m³/s,3,6,8,11,14,17,19,22,25,28 9

More information

DOMEKT Residential ventilation units

DOMEKT Residential ventilation units VENTILTION equipment Komfovent equipment SUMMRY Komfovent range Komfovent air handling units create healthy indoor climate ensuring an efficient energy saving. The designed products meet a high quality

More information

Page 2 of 16. DOMEKT price-list PRICE-LIST Prices in POUND STERLING excluding VAT. Prices are valid for year 2018.

Page 2 of 16. DOMEKT price-list PRICE-LIST Prices in POUND STERLING excluding VAT. Prices are valid for year 2018. Domekt Units PRICE GUIDE 2018 price-list 2018 PRICE-LIST air handling units are designed for the ventilation of residential premise. series offers the standardized range of air handling units with heat

More information

17 Domekt R. Units with a rotary heat exchanger. Domekt RHP Units with a rotary heat exchanger and an integrated heat pump.

17 Domekt R. Units with a rotary heat exchanger. Domekt RHP Units with a rotary heat exchanger and an integrated heat pump. VENTILTION equipment VENTILTION equipment SUMMRY Komfovent range Komfovent air handling units create healthy indoor climate ensuring an efficient energy saving. The designed products meet a high quality

More information

VERSO Air Handling Units

VERSO Air Handling Units Energy efficient solutions for profitable indoor climate VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P air handling units equipped with recuperation system

More information

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h VENTILATION equipment VENTILATION equipment content DOMEKT Residential ventilation units 50 1 000 m³/h 15 VERSO Non residential ventilation units 1000 34 000 m³/h 61 Domekt R 17 Domekt R 200 V 19 Domekt

More information

AHU N : Range: VERSO VERSO. Air handling units. Plug & Play Energy Saving Smart Design Reliable & Safe

AHU N : Range: VERSO VERSO. Air handling units. Plug & Play Energy Saving Smart Design Reliable & Safe HU N : 07.09.356 Range: VERSO ir handling units VERSO Plug & Play Energy Saving Smart esign Reliable & Safe VERSO ir Handling Units VERSO-S air supply units VERSO-R air handling units with a rotary heat

More information

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation Air handling units KLASIK Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation KLASIK air handling units Customer oriented and unique

More information

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h VENTILTION equipment VENTILTION equipment content OMEKT Residential ventilation units 50 1 000 m³/h 15 VERSO Non residential ventilation units 1000 34 000 m³/h 61 omekt R 17 omekt R 200 V 19 omekt R 250

More information

Energy efficient ventilation equipment

Energy efficient ventilation equipment Energy efficient ventilation equipment Komfovent Energy Efficient KOMFOVENT is a trademark for ventilation products produced by the company AMALVA. KOMFOVENT stands for comfort, healthy indoor climate,

More information

VERSO-P, VERSO-R Series Air Handling Units with C3 Control System Electrical Installation and Operation Manual

VERSO-P, VERSO-R Series Air Handling Units with C3 Control System Electrical Installation and Operation Manual VERSO-P, VERSO-R Series Air Handling Units with C3 Control System Electrical Installation and Operation Manual EN Table of Contents 1. INSTALLATION MANUAL...3 1.1. Air Handling Units Sections Connection...3

More information

VR 400/700 DCV/DC. Good ventilation For dwellings, smaller offices and business premises. com

VR 400/700 DCV/DC. Good ventilation For dwellings, smaller offices and business premises.   com VR 400/700 V/ Good ventilation or dwellings, smaller offices and business premises www.systemair. com Ventilation has one main aim. It should take away the consumed air that contains all the pollution

More information

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h PRODUCT DATA COMFORT 40 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 40 m /h COMFORT 40 Product description The Comfort 40 is an energy-efficient ventilation

More information

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h PRODUCT DATA COMFORT 00 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 800 m /h COMFORT 00 Product description The Comfort 00 is an energy-efficient ventilation

More information

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery. PRODUCT DATA COMBI 300 POLAR BY NILAN Ventilation with passive & active heat recovery Domestic Passive heat recovery Active heat recovery Ventilation < 350 m 3 /h Comfort heating Comfort cooling COMBI

More information

VERSO. Commercial ventilation units 01/03/ Tél

VERSO. Commercial ventilation units 01/03/ Tél VERSO ommercial ventilation units istribué par ERI : contact@aeria-france.fr KOMFOVENT fabriqué par : U MLV www.komfovent.com SOUS RÉSERVE E MOIFITION SNS PRÉVIS 1/3/218 www.aeria-france.fr Tél 2 51 13

More information

KOMFORT EC DB Suspended heat recovery air handling units

KOMFORT EC DB Suspended heat recovery air handling units 2018 AIR HANDLING UNITS KOMFORT EC DB Suspended heat recovery air handling units Features Air handling units for efficient supply and exhaust ventilation in flats, houses, cottages and other buildings.

More information

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans! AIR HANDLING UNITS RIS P EKO 3.0 1 2 3 4 fans! Efficient EC E f f i c i e n c y up to 94%! E x t r e m e l y low height! New range - 5 sizes, 20 models! Contents Basic features 4 RIS P EKO 3.0 full range

More information

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION Swegon CASA W130 Ventilation unit with counter-flow plate heat exchanger Ventilation unit for residential houses under 250 m². The unit has counter-flow plate heat exchanger. Suitable also for renovation

More information

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses REC Temovex 4S-EC-RS Experts on indoor climate in low-energy houses RT 4S-EC-RS REC Temovex 4S-EC-RS ECO2 control system for low-energy and passive houses Comprises: - Air flow boost for warm and cold

More information

Elektros montavimo ir eksploatavimo instrukcija 2 Electrical installation and Operation Manual 18 Инструкция по электромонтажу и эксплуатации 34

Elektros montavimo ir eksploatavimo instrukcija 2 Electrical installation and Operation Manual 18 Инструкция по электромонтажу и эксплуатации 34 domekt rego / recu LT RU Elektros montavimo ir eksploatavimo instrukcija 2 Electrical installation and Operation Manual 18 Инструкция по электромонтажу и эксплуатации 34 Content 1. ELECTRICAL INSTALLATION

More information

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 % Single-room heat recovery unit Air flow up to 59 CFM Heat recovery efficiency up to 96 % 2018 SINGLE-ROOM HEAT RECOVERY UNITS Features Efficient solution for supply and exhaust ventilation of enclosed

More information

DOMEKT ReGO 400VE(W)-B Series Air Handling Units Installation and Maintenance Service Manual

DOMEKT ReGO 400VE(W)-B Series Air Handling Units Installation and Maintenance Service Manual DOMEKT ReGO 400VE(W)-B Series Air Handling Units EN Content Safety Requirements...3 Transportation...3 Brief Description of the Unit...5 Installation...6 Maintenance...11 Technical Information......13

More information

Home Solutions for Residential Ventilation

Home Solutions for Residential Ventilation Fans ir Handling Units ir Distribution Products Fire Safety ir Conditioning ir Curtains and Heating Products Tunnel Fans Home Solutions for Residential Ventilation Technical specification for SVE units

More information

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION Swegon CASA R120 Ventilation unit with rotary heat exchanger Ventilation unit for residential houses, multi-storey buidings and holiday cottages under 230 m 2. The unit is equipped with rotary heat exchanger.

More information

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S Heat and Energy Recovery Ventilators 2018 AIR HANDLING UNITS 2 CONTENT KOMFORT EC S5B270(-E) 4 KOMFORT EC D5B1(-E) 8 KOMFORT EC S(B)(-E) 12 AIR HANDLING UNITS

More information

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h PRODUCT DATA COMFORT 300 TOP BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 325 m 3 /h COMFORT 300 TOP Product description The Comfort 300 Top is an energy-efficient

More information

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h PRODUCT DATA COMFORT 450 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 450 m 3 /h COMFORT 450 Product description The Comfort 450 is an energy-efficient ventilation

More information

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h PRODUCT DATA COMFORT 5000 BY NILAN Ventilation & passive heat recovery Commercial Passive heat recovery Ventilation < 5300 m 3 /h COMFORT 5000 The Comfort 5000 is a ventilation unit suitable for central

More information

Flexit air handling units UNI 2, 3 og 4

Flexit air handling units UNI 2, 3 og 4 Flexit handling units UNI 2, 3 og 4 energy efficient ventilation for a healthy indoor environment FOR A HEALTHY INDOOR ENVIRONMENT Energy-efficient ventilation Flexit UNI 2, 3 and 4 The handling units

More information

Specification data Topvex. Rotating or Cross flow heat exchanger.

Specification data Topvex. Rotating or Cross flow heat exchanger. Specification data Topvex Rotating or ross flow heat exchanger www.systemair.com Topvex Topvex SR, TR, SX and TX is a series of efficient ventilation units designed for offices, shops, schools, daycare

More information

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning AIR HANDLING UNITS WITH HEAT RECOVERY Series VENTS enthalpy membrane in the warm season. This allows for a considerable reduction of the supply air temperature and humidity which, in turn, reduces the

More information

Flexit air handling units C2 and UNI 2, 3,4

Flexit air handling units C2 and UNI 2, 3,4 Flexit handling units C2 and UNI 2, 3,4 energy efficient ventilation for a healthy indoor environment A FOR A HEALTHY INDOOR ENVIRONMENT Energy-efficient ventilation Flexit C2 and UNI 2, 3, 4 The handling

More information

DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION

DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION 2 AERECO DX system DX SYSTEM A COMPLETELY NEW HEAT RECOVERY VENTILATION RANGE With the experience of a very innovative room-by-room demand

More information

Heat recovery unit RDKS

Heat recovery unit RDKS Heat recovery unit RDKS Heat recovery unit RDAS is based on our RDAR unit and develops this further. The unit has a rotary heat exchanger with stepless speed control. This allows for very precise temperature

More information

CONTENT: VEX308 Decentralised ventilation VEX308

CONTENT: VEX308 Decentralised ventilation VEX308 CONTENT: VEX308 Decentralised ventilation VEX308 VEX308 Decentralised ventilation Download all product data on VEX308 General VEX308 - decentralised ventilation for schools, institutions and offices A

More information

Energy efficient ventilation equipment

Energy efficient ventilation equipment Energy efficient ventilation equipment Komfovent Energy Efficient Air Handling Units KOMFOVENT is a trademark for ventilation products produced by the company AMALVA. KOMFOVENT stands for comfort, healthy

More information

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25 Residential Heat Recovery Ventilation REHVA European Guidebook No 25 REHVA European Guidebook No 25 2 Limited to mechanical supply and exhaust ventilation Targeted to engineers, HVAC consultants and contractors

More information

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY Product Overview www.orcaenergy.eu MAXI Device for heat recovery MAXI is designed to provide permanent controlled air exchange by means of mechanical ventilation

More information

Swegon CASA R85. Ventilation unit with rotary heat exchanger HOME VENTILATION

Swegon CASA R85. Ventilation unit with rotary heat exchanger HOME VENTILATION Swegon CASA R85 Ventilation unit with rotary heat exchanger Ventilation unit for residential houses, multi-storey buidings and holiday cottages under 170 m 2. The unit is equipped with rotary heat exchanger.

More information

PRODUCT DATA COMFORT 302 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 345 m 3 /h

PRODUCT DATA COMFORT 302 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 345 m 3 /h PRODUCT DATA COMFORT 302 TOP BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 345 m 3 /h COMFORT 302 TOP Product description The Comfort 302 Top is an energy efficient

More information

DOMEKT ReCU 400VE(W)CF-EC-C4 Series Air Handling Units Installation and Maintenance Service Manual

DOMEKT ReCU 400VE(W)CF-EC-C4 Series Air Handling Units Installation and Maintenance Service Manual DOMEKT ReCU 400VE(W)CF-EC-C4 Series Air Handling Units Installation and Maintenance Service Manual EN Content Safety Requirements...3 Transportation...3 Brief Description of the Unit...5 Installation...6

More information

Healthy, comfortable and energy-efficient ventilation

Healthy, comfortable and energy-efficient ventilation Healthy, comfortable and energy-efficient ventilation 300/400/450 180 Renovent Excellent 180, 300, 400 and 450 Silent and energy-efficient ventilation Central ventilation The Renovent Excellent is a mechanical

More information

Eco Active H E A T R E C O V E R Y S Y S T E M S. Heat Recovery Penthouse Turret. W: T:

Eco Active H E A T R E C O V E R Y S Y S T E M S. Heat Recovery Penthouse Turret. W:   T: Eco Active Heat Recovery Penthouse Turret W: www.gdl.co.uk T: 01457 861538 Heat Recovery Penthouse Turret The HRPT provides ventilation into spaces all year round. The unit provides 100% fresh air whilst

More information

Healthy, comfortable and energy-efficient ventilation

Healthy, comfortable and energy-efficient ventilation Healthy, comfortable and energy-efficient ventilation partner Renovent Excellent 180, 300 and 400 Silent and energy-efficient ventilation 300/400 180 Central ventilation The Renovent Excellent is a mechanical

More information

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 % FRESHBOX 100 Single-room heat recovery unit Air capacity up to 100 m³/h Heat recovery efficiency up to 96 % FRESHBOX 100 CONTENTS FRESHBOX 100 FEATURES 3 DESIGN 4 OPERATING PRINCIPLE 6 CONTROL 6 APPLICATION

More information

TSEK VHR EC HEAT RECOVERY UNITS

TSEK VHR EC HEAT RECOVERY UNITS TSEK EC HEAT RECOVERY UNITS TS EN ISO 9001:2008 SN: 01 100 901925 General Information TSEK VENCO Heat Recovery Ventilation Units () are designed for saving energy and also improving indoor air quality.

More information

VALLOX VENTILATION PRICELIST 2018

VALLOX VENTILATION PRICELIST 2018 VALLOX VENTILATION PRICELIST 2018 1.1.2018 VENTILATION SYSTEM YOUR BEST LIFE INSURANCE Good ventilation is an important investment in the health of the house and its inhabitants, and also affects the lifespan

More information

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions) NUAIRE MVHR (including opposite handed versions) ACHIEVES 100% DUTY IN BYPASS MODE and MRXBOXAB- ECO-LP1-OH are specically designed for apartment applications where space is a premium. The new MRXBOX95-LP1

More information

Demand-controlled Ventilation Leading edge products for demand-controlled ventilation

Demand-controlled Ventilation Leading edge products for demand-controlled ventilation Overview Demand-controlled Ventilation Leading edge products for demand-controlled ventilation Demand-controlled ventilation offers great comfort and low operating costs When the room is in use, ventilation

More information

PRODUCT DATA COMPACT S BY NILAN. Sanitary hot water production. Passive heat recovery. Comfort heating. Ventilation < 375 m 3 /h. Active heat recovery

PRODUCT DATA COMPACT S BY NILAN. Sanitary hot water production. Passive heat recovery. Comfort heating. Ventilation < 375 m 3 /h. Active heat recovery PRODUCT DATA COMPACT S BY NILAN Domestic Passive heat recovery Active heat recovery Ventilation < 375 m 3 /h Comfort heating Comfort cooling Sanitary hot water production COMPACT S Product description

More information

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction Air Comfort Air Treatment Energy Recovery eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction eco PREMIUM - Technical Instruction REDA 2 Contents Description Applications... 3 Quality & environment...

More information

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h VENTILATION equipment VENTILATION equipment content DOMEKT Residential ventilation units 50 1 000 m³/h 15 VERSO Non residential ventilation units 1000 34 000 m³/h 61 Domekt R 17 Domekt R 200 V 19 Domekt

More information

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h PRODUCT DATA COMFORT 00 BY NILAN Ventilation & passive heat recovery Commercial Passive heat recovery Ventilation < 00 m /h COMFORT 00 The Comfort 00 is a ventilation unit suitable for central ventilation

More information

SINGLE-ROOM VENTILATION. for schools and public spaces

SINGLE-ROOM VENTILATION. for schools and public spaces SINGLE-ROOM VENTILATION for schools and public spaces Industrial and commercial ventilation (Catalogue no. 1) Industrial and commercial ventilation components - fans for round and rectangular ducts, sound-insulated,

More information

EASYAIR COMPACT DEVICE THE EASY WAY OF AIR HANDLING.

EASYAIR COMPACT DEVICE THE EASY WAY OF AIR HANDLING. EASYAIR COMPACT DEVICE THE EASY WAY OF AIR HANDLING. EASYAIR THE EASY WAY OF AIR HANDLING Independently VDI 6022 tested and certified down to the last detail The new generation of EASYAIR compact devices

More information

Controlled mechanical ventilation GB 03

Controlled mechanical ventilation GB 03 RECUPER SLIM 2018 Controlled mechanical ventilation GB 03 ir conditioning Systems to install Recover... your wellbeing The home is a precious asset where we all spend a major time of your life. So it s

More information

AIR HANDLING UNITS ver B

AIR HANDLING UNITS ver B AIR HANDLING UNITS www.salda.lt 2013 ver B EC High efficiency air handling units are supplied with crosscounter flow plate heat exchangers. AHU is used for ventilation of houses and other heated areas.

More information

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h VENTILATION equipment VENTILATION equipment content DOMEKT Residential ventilation units 50 1 000 m³/h 15 VERSO Non residential ventilation units 1000 34 000 m³/h 61 Domekt R 17 Domekt R 200 V 19 Domekt

More information

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses NEW! REC Temovex Blue 4 Experts on indoor climate in low-energy houses REC Temovex Blue 4 Third generation of our Temovex units! - Dual counterflow heat exchangers with over 9% efficiency * - SFP < 1,

More information

WORLD VENTILATION LEADER SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS

WORLD VENTILATION LEADER   SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS WORLD VENTILATION LEADER IO EM.COM SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS VENTS reserves the rights to modify any of its products featuers, designs, components and specifications

More information

... RTU. Packaged Air to Air Heat Pump...

... RTU. Packaged Air to Air Heat Pump... ... RU Packaged ir to ir Heat Pump... RU... Packaged ir to ir Heat Pump... Reznor's RU range is composed of air to air heat pumps in packaged rooftop configurations, with various heat recovery options

More information

2013 innovation. Room-by-room demand controlled heat recovery ventilation

2013 innovation. Room-by-room demand controlled heat recovery ventilation 2013 innovation Room-by-room demand controlled heat recovery ventilation 2 Revolution in the world of heat recovery ventilation Through its new ventilation system, which combines heat recovery and room-by-room

More information

ROOM-BY-ROOM DEMAND CONTROLLED HEAT RECOVERY VENTILATION

ROOM-BY-ROOM DEMAND CONTROLLED HEAT RECOVERY VENTILATION ROOM-BY-ROOM DEMAND CONTROLLED HEAT RECOVERY VENTILATION 2 AERECO Room-by-room demand controlled heat recovery ventilation REVOLUTION IN THE WORLD OF HEAT RECOVERY VENTILATION Through its new ventilation

More information

Breathe Fresh Air at Home

Breathe Fresh Air at Home Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans Breathe Fresh Air at Home Residential Ventilation 2 Category name / Registername

More information

RIS V EKO A1/L2 RIS 700 V E L EKO 3.0 AIR HANDLING UNITS. Application

RIS V EKO A1/L2 RIS 700 V E L EKO 3.0 AIR HANDLING UNITS. Application EC A1/L2 7 1 19 2 75 Application Ventilation of houses, offices or other heated premises (classrooms, apartments, conference rooms, etc.) Description RIS V EKO 3. is a range of heat recovery units with

More information

Smart air handling unit for swimming pools IN CONFORMITY WITH THE REQUIREMENTS OF

Smart air handling unit for swimming pools IN CONFORMITY WITH THE REQUIREMENTS OF Smart air handling unit for swimming pools IN CONFORMITY WITH THE REQUIREMENTS OF PERSONALIZED CORROSION-RESISTANT SAVING AmberAir Pool FOR A COMFORTABLE MICROCLIMATE AT A SWIMMING POOL AmberAir Pool units

More information

TopMaster Air Handling unit. Technical data

TopMaster Air Handling unit. Technical data Technical data Contents Page Description of the unit... 3 Design... 4 Technical data Size 030... 5 Size 0... 6 Accessories... 7 Controls... 9 Control functions... 10 Order codes... 11 Fläkt Woods 8180

More information

Technical Information HXV - HRV Ventilation

Technical Information HXV - HRV Ventilation Technical Information HXV - HRV Ventilation General description Technical data Accessories VENTILATION HXV 5 1 General description 1.01-1.02 2 Technical data 2.01-2.02 3 Accessories 3.01-3.03 HRV 5 4 General

More information

Series VENTS VUT R WH ЕС

Series VENTS VUT R WH ЕС AIR HANDLING UNITS WITH HEAT RECOVERY Series VENTS EH ЕС Series VENTS WH ЕС Air handling units with the air capacity up to 1500 m 3 /h in soundand heat-insulated casing with integrated electric heater.

More information

Heat Recovery Unit HERU. web-version

Heat Recovery Unit HERU. web-version Heat Recovery Unit HERU web-version HERU 50 and 75 Heat recovery unit HERU is designed to suit places like houses, offices and other buildings where there is a big demand for high temperature efficiency,

More information

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9 ERV/ HRV CONTENTS Horizontal rotor heat recovery ventilation unit RH 5 Vertical rotor heat recovery ventilation unit RV 9 Suspended plate heat recovery ventilation unit CFP Horizontal plate heat recovery

More information

VEX100 series Air handling units with cross-flow heat exchanger

VEX100 series Air handling units with cross-flow heat exchanger Product information - Version 6 VEX100 series Air handling units with cross-flow heat exchanger VEX140: 400-2200 m 3 /h VEX150: 700-3600 m 3 /h VEX160: 1100-5000 m 3 /h VEX170: 1400-8400 m 3 /h Contents

More information

OVERVIEW and SYSTEM GUIDE. Swegon CASA. Residential ventilation for optimal operating economy and the greatest comfort.

OVERVIEW and SYSTEM GUIDE. Swegon CASA. Residential ventilation for optimal operating economy and the greatest comfort. OVERVIEW and SYSTEM GUIDE Swegon CASA Residential ventilation for optimal operating economy and the greatest comfort. www.swegon.com Swegon your system supplier Supply air diffuser Vapour barrier for duct

More information

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units. AIR HANDLING UNITS WITH HEAT RECOVERY Series VUT PE EC Series SAS908 control panel SAS908 control panel Ceiling mounted energy saving Air Handling Units (AHU) with the air capacity up to 4000 m 3 /h and

More information

COMPACT VENTILATION UNITS DUPLEX EC5

COMPACT VENTILATION UNITS DUPLEX EC5 N OMPT VNTILTION UNITS UPLX 5 2016 2018 OMPNY HISTORY TR PROUTS TR was started as a private company in 1990 in the zech Republic. Very shortly it began to focus on the production of ventilation units with

More information

Domestic fans. Circular duct fans 1. Rectangular duct fans 2. Roof fans 3. Axial fans 4. Smoke evacuation fans 5.

Domestic fans. Circular duct fans 1. Rectangular duct fans 2. Roof fans 3. Axial fans 4. Smoke evacuation fans 5. Domestic fans Circular duct fans Rectangular duct fans Roof fans xial fans Smoke evacuation fans TEX rated fans Corrosion resistant fans Domestic fans ccessories Wiring diagrams 0 Index Content Centrifugal

More information

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation NUAIRE MVHR and Opposite Handed version ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due to its intelligent

More information

EC A1/L2 RIRS V EKO AIR HANDLING UNITS

EC A1/L2 RIRS V EKO AIR HANDLING UNITS EC A1/L2 Application Description Ventilation of houses, small public buildings, offices or other heated premises (classrooms, apartments, conference rooms, etc.). RIRS V EKO 3.0 is a range of heat recovery

More information

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini... Contents How to choose Recovery Ventilation type?............................................3 How do HRV, ERV and TRV Systems work?............................................4 Types of installations..............................................................5

More information

AIR HANDLING UNITS. AmberAir Compact Smarty RIS EKO 3.0 RIRS EKO 3.0

AIR HANDLING UNITS. AmberAir Compact Smarty RIS EKO 3.0 RIRS EKO 3.0 Residential/commercial units selection program: http://salda.lt/en/selection/ahu AmberAir Compact units selection program VentMaster: http://salda.lt/en/pros/category/download_page/ WWW.SALDA.LT Rotor

More information

Energy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1)

Energy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1) c a i r c im M Si l g n e r m o o ai a h r r ving i a a ze h s gy s t si e Fr e r p a c En m Co a r th i y w r t s ov e i un rec g t n li ea d n h in t e til oun a rs m ise e V sy no Ea w Lo g Industrial

More information

Domestic & Commercial Fans

Domestic & Commercial Fans Max. airflow l/s Axial Fan Centrifugal Fan Speed Controllable Reversible Airflow Page Number BF IF CF CBF BF 64 * 16 IF 64 * 16 EAF LV 23 * 169 ECF LV 31 * 169 CF 25 * 170 CBF 31 * 170 RVF 0 * * 171 BRAVO

More information

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT AIR TREATMENT ReCOOLER HP ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT Energy efficiency the essence of our solutions All our research, development

More information

Plus Perimeter Aspiration Timer Remote control predisposition

Plus Perimeter Aspiration Timer Remote control predisposition Island Plus Perimeter Aspiration Timer Remote control predisposition Features Installation Finish Controls N. Motors Portata Max Recycling Max Noise Level Min Noise Level Total Absorption Dimensions Lighting

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION Vallox 50C FFCT.09.79b.8.009 Code 5 VALLOX Code 5 TCHNICAL PCIFICATION For dwelling-specific ventilation upply and extract air ventilation with heat recovery ilent operation nergy-efficient unit; high-efficiency

More information

Refrigerated Air Dryers

Refrigerated Air Dryers Refrigerated ir ryers /IU Series Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic

More information

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter VALLOX Product Code: 3158400 L 3158410 R SILENCER (OPTIONAL) INSTRUCTIONS FOR USE AND MAINTENANCE WATER CIRCULATED POST-HEATING UNIT (OPTIONAL) ELECTRIC POST-HEATING UNIT (OPTIONAL)) PREHEATER (OPTIONAL)

More information

RHC GAS FIRED HEATING COILS

RHC GAS FIRED HEATING COILS CI/SfB 56.83 X RHC GS FIRED HETING COILS RHC GS FIRED REZNOR HETING COILS Introduction Reznor gas fired heating coils are designed for inclusion in air handling units to provide a high efficiency gas fired

More information

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools Dehumidification and ventilation for residential, industrial radiant systems and swimming pools HiDew is proud to present a complete range of dehumidifiers for radiant cooling systems and high performance

More information

HCV 4 - HCV 5 - HCH 5 - HCH 8

HCV 4 - HCV 5 - HCH 5 - HCH 8 HCV 4 - HCV 5 - HCH 5 - HCH 8 R E S I D E N T I A L V E N T I L AT I O N W I T H H E AT R E C O V E R Y I M P R O V E YO U R I N D O O R C L I M AT E A N D S AV E E N E R G Y DANTHERM RESIDENTIAL VENTILATION