fiftycoolyears IT Cooling start here English rcgroupairconditioning

Size: px
Start display at page:

Download "fiftycoolyears IT Cooling start here English rcgroupairconditioning"

Transcription

1 fiftycoolyears IT Cooling start here English rcgroupairconditioning

2

3 IT Cooling Index INTRODUCTION Certifications... 5 References... 6 Company profile... 7 Production plants... 9 Web & Social media Legenda Products selection RC Group Software RC Group for IT Cooling Highlights NEW GO GREEN Solutions DT CENTER IR CONDITIONERS NEW X TYPE NEXT EVO INV DX Chilled water feeding close control air conditioners Close control air conditioners with inverter driven compressors NEW NEW NEW NEW NEXT EVO INV DW NEXT EVO CW S NEXT EVO CW K NEXT EVO DX Close control air conditioners with inverter driven compressors Chilled water feeding close control air conditioners Chilled water feeding close control air conditioners Direct expansion close control air conditioners NEXT DW Direct expansion close control air conditioners NEXT DL Close control air conditioners with displacement air delivery NEXT MTR Close control air conditioners for metrological rooms COOLROW Direct expansion and chilled water feeding close control air conditioners COOLSIDE EVO DX SYSTEM Direct expansion air conditioning system for high density racks...91 COOLSIDE EVO CW Chilled water feeding air conditioning system for high density racks IR CONDITIONERS FOR TELECOMMUNICTION ENERGY SPLIT Telecommunication split-system air conditioner with Free-Cooling system MINIPC Telecommunication packaged air conditioner with Free-Cooling system ENERTEL Telecommunication packaged air conditioner with Free-Cooling system MRK Telecommunication packaged air conditioner with Free-Cooling system IR COOLED FREE-COOLING LIQUID CHILLERS MXIMO ir cooled free-cooling liquid chillers MXIMO PF ir cooled free-cooling liquid chillers EGLE FREE ir cooled free-cooling liquid chillers GLIDER EVO FREE ir cooled free-cooling liquid chillers GLIDER EVO FREE CL ir cooled free-cooling liquid chillers in class energy efficiency UNICO TURBO FL FREE ir cooled free-cooling liquid chillers with oil-free centrifugal compressors NEW UNICO TURBO FLG FREE ir cooled free-cooling liquid chillers with oil-free centrifugal compressors - HFO1234ze 157 LIQUID CHILLERS EQUIPPED WITH CENTRIFUGL OIL-FREE COMPRESSORS UNICO TURBO FL Liquid chillers equipped with centrifugal oil-free compressors NEW UNICO TURBO FLG FRIGO TURBO FL Liquid chillers equipped with centrifugal oil-free compressors - HFO1234ze Liquid chillers equipped with centrifugal oil-free compressors NEW FRIGO TURBO FLG Liquid chillers equipped with centrifugal oil-free compressors - HFO1234ze IR COOLED CONDENSERS TEM MTE ir cooled condensers equipped with axial fans TEM MTE PF ir cooled condensers equipped with plug-fans DRY COOLERS DRY COOLER Dry coolers equipped with axial fans DRY COOLER PF Dry coolers equipped with plug-fans SELECTION SOFTWRE RC WORLD RC Group s selection software SPECTRUM RC Group s energy analysis software SPECTRUM tutorial SPECTRUM: Video tutorial UNITS MNGEMENT SOFTWRE NEW COOLNET SEQUENCER Intelligent NET for IT Cooling Sequencer NEW RC CLOUD PLTFORM Performance and quality remote monitoring fiftycoolyears RCGROUP Sp G_ITC_RCW8.4 3

4 fiftycoolyears Please register on our web site for the download of all technical and commercial documentation. 4 G_CHL_RCW8.4 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

5 Certifications ISO 9001:2008 CERTIFICTION For production plants of Valle Salimbene (PV) and Zeccone (PV) Italy RC GROUP S.p.. has been the first European company in HVC field to get the ISO 9001 certification in 1991: all the processes are certified to assure products and services in compliance with the corporate policy. ISO 14001:2004 CERTIFICTION For production plants of Valle Salimbene (PV) and Zeccone (PV) Italy RC GROUP S.p.. chose to establish, maintain and improve its environmental management system. Its organisation is certified according to UNI EN ISO 14001:2004. ISO 9001:2000 GB/T CERTIFICTION For the production plant of Foshan, Guangzhou People s Republic of China The headquarters RC GROUP S.p.. in the Republic of China has achieved ISO 9001 and GB / T certification in 2009, for the assembly and sale of Precision ir Conditioners. TR CERTIFICTION - DECLRTION OF CONFORMITY EC (RUSSIN FEDERTION, BELRUS, KZKHSTN) For RC Group products RC GROUP S.p.. products has obtained the TR Certification and the Declaration of conformity EC. They attest the product conformity to the products safety standards of the Eurasian Custom Union: Russian Federation, Belarus and Kazakhstan. P.E.D. CERTIFICTION For production plants of Valle Salimbene (PV) and Zeccone (PV) Italy RC GROUP S.p.. products meet the requirements of module H category II and III of the European directive 97 / 23CE and subsequent modifications for pressure equipment. EUROVENT CERTIFICTION For production plants of Valle Salimbene (PV) and Zeccone (PV) Italy RC GROUP S.p.. participated in the EUROVENT certification program for LCP and HP (Liquid Chilling Packages and Heat Pumps). CE MRKING For production plants of Valle Salimbene (PV) and Zeccone (PV) Italy The Liquid Chillers and the ir Conditioners produced by RC GROUP S.p.. are in compliance with the European Directives 2006 / 42CE, 2006 / 95CE, 2004 / 108CE, 97 / 23CE and subsequent modifications. Eurovent is an international organization of manufacturers that works to improve the standards of products for air-conditioning and refrigeration systems throughout the European market. The members of this organization voluntarily submit their products to a network of independent laboratories approved for testing and evaluation in accordance with European and international standards. The participation in this certification program ensure that the specifications of the products presented by RCGroup in its commercial and technical literature are clear and transparent. Check ongoing validity of certification on web site: fiftycoolyears RCGROUP Sp G_ITC_RCW_8.4 5

6 References Senato della Repubblica Istat EEC rdenne trium European Parliament Bruxelles McDonald s GRUPPO BNCRIO Credito Valtellinese Banca Popolare di Sondrio G Logos, Trade Marks and Companies Name are property of respective Owners 6 G_ITC_RCW_8.4 RCGROUP Sp fiftycoolyears

7 Company Profile TIME STISFCTION RC Group started its activity in 1963, devoting itself to the emerging Technologies of that time for computer rooms cooling technology, telecommunication, metrology labs, etc.... Only a short time later RC Group opens a new universe with a wide range of refrigeration, heat pump and multifunction units able to satisfy every possible demand for comfort and to satisfy several industrial cooling processes. Since 2011, RC Group has joined DeLclima Sp, the holding company of De Longhi group, mainly devoted to the production and sale of air conditioning equipment. Time, space, technological evolution, quality and environment, tailor-made solutions, all of these elements together can lead to the achievement of our main aim: the customer s full satisfaction, either for properly tested products or for the capillary presence of skilled technicians and for the thick service network on the territory, providing with the units maintenance. Over against the newest overview constantly changing, the proposal of complete solutions conceived for the efficiency and functionality only can supply the right response to the market. This is the today s strategy that is giving very satisfying results to the final users, buyers and RC Group. QULITY & ENVIRONMENT TILOR-MDE SOLUTIONS Through the originality of its projects, RC Group demonstrates its prompt ability to address and meet new and different demands by continuing to develop innovative responses. lways, RC Group raises challenges, facing new application realities within a market in constant evolution and offering tailor-made solutions meeting with accurate precision the single customer needs. The assurance of the quality of all products from RC Group factory is determined by rigorous tests carried out in the laboratories and in the numerous test benches, where each device is electrically and hydraulically connected to carry out functional calibrations according to the specific requirements of each single customer. In several cases, thanks to its experience linked to innovation, RC Group has proposed and realized efficient and dedicated solutions in the most critical contexts too. Instruments to speed-up the process for the realization of its projects, increasing the customer satisfaction degree. ll the design, production and test procedures are in accordance with ISO 9001 norms. In the respect of the environmental protection RC Group is certified in accordance with ISO14001 norms. Nowadays, RC Group is facing the market as supplier of several products: air conditioners and liquid chillers, covering a range of cooling capacities from 5 to over 2000 per unit to satisfy any kind of needs fiftycoolyears RCGROUP Sp G_ITC_RCW_8.4 7

8 Company Profile TECHNOLOGICL EVOLUTION SPCE RC Group products are the result of a technological growth based on the experiences made over fifty years of activity in the air conditioning for data centers applications, metrology labs, telecommunication and comfort, besides all several and specific equipment for refrigeration and water heating of small, medium and large capacity. The company designs and produces through sophisticated computerized systems that allow to obtain perfect and high quality equipment in respect of the current European and Worldwide regulations. Tridimensional CD, thermodynamic and acoustical simulators for machines and plants design.. and RC World. The character of the company and its philosophy of research and development, design and production, were quickly recognized and appreciated by the market, in Italy first and then worldwide. RC Group manufactures air conditioners and small, medium and large capacity liquid chillers at its three plants in Pavia (Italy). fourth production unit, only for precision air conditioning equipment manufacture is located in Foshan (China) to give a quick and economically competitive response to all the requests from the Far East. unique commercial software available for the sales network, able to manage all RC Group World through few links: from the comparison of the technical data to the product selection, up to the commercial offer and order processing. The commercial and service widespread coverage is made up of a number of agencies and service centers in Italy as well as many product distribution and service companies to the rest of the World, in order to be always in the middle of the action. Wherever you are, RC Group is always at your side. FOUR PRODUCTION SECTORS IN ONE ONLY SOLUTION IT cooling Chillers Heat Pumps & Multifunction rtificial Intelligence IT cooling Precision air conditioners designed for data centers, telephone exchanges, shelters. Chillers Liquid chillers for food, textile, pharmaceutical and electronic big industries. Heat pumps & Multifunction Multifunction liquid chillers and heat pumps suitable for installation in supermarkets and business centers, banks, public offices, airports, hospitals. rtificial Intelligence dvanced software tools for units selection, energy efficiency calculation, networking and remote monitoring. Since over fifty years, RC Group supplies reliable and flexible solutions and it is today considered the market leading company in precision air conditioning and refrigeration with high-tech content. 8 G_ITC_RCW_8.4 RCGROUP Sp fiftycoolyears

9 Production plants RC GROUP - VLLE SLIMBENE valle salimbene RC GROUP - VLLE SLIMBENE - LRGE CPCITY valle salimbene Location: Valle Salimbene, 30km from Milan Production: Chillers & Heat pumps Surface: total 36500m 2, covered 9300m 2 Employees: 125 Headquarters, R&D, production plant Location: Valle Salimbene, 30km from Milan Production: Large capacity chillers & heat pumps Surface: covered 2300m 2 Employees: 20 Start up on year Production plant. RC GROUP - ZECCONE zeccone FOSHN - RC IR CONDITIONING foshan Location: Zeccone, 20km from Milano Production: CCU and TLC mobile units. Surface: total 7500m 2, covered 4200m 2 Employees: 60 Start up on year Production plant. Location: Foshan, Guangdong (Cina) Production: CCU for Far East market. Surface: total 3000m 2, covered 2600m 2. Employees: 25 Production plant and sales & marketing department for Far East market RC GROUP LOGO EVOLUTION fiftycoolyears fiftycoolyears RCGROUP Sp G_ITC_RCW_8.4 9

10 Web & Social Media RC GROUP WEB YOU TUBE CHNNEL LINKEDIN 10 G_ITC_RCW_8.4 RCGROUP Sp fiftycoolyears

11 Legenda Symbols used in the catalogue. NEW PRODUCT RNGE EXTENSION REFRIGERNT CHRGE HFO 1234 ZE LOW GWP (Global Warming Potential) NEW SOFTWRE NEW SOFTWRE NO ODP (No Ozone Depletion Potential) NOODP CLSS, + CLSS ENERGY EFFICIENCY CLSS + LOW TEWI (Total Equivalent Warming Impact) HIGH ENERGY EFFICIENCY CHILLED WTER FEEDING FREE-COOLING SYSTEM INVERTER DRIVEN COMPRESSOR USE OF PURE WTER IN THE HYDRULIC CIRCUIT OF THE PLNT DOUBLE POWER SUPPLY LOW NOISE EMISSIONS DELT T-10 - CHW IN/OUT DEFROSTING SYSTEM WITH DYNMIC REDING OF WORKING PRMETERS X TYPE EVPORTING COILS XCOILS energy class machine CLSS Microchannel type condensing coil MICRO CHNNEL Plate type evaporator PLTE Only cooling Shell and tube type evaporator SHELL Only heating Flooded shell and tube evaporator FLOODED Cooling/Heating Domestic hot water xial fans with brushless type EC type electric motor E C xial fans with C type electric motor C Scroll type compressor Screw type compressor Oil free centrifugal compressor Plug fans with brushless type EC type electric motor Plug fans with C type electric motor E C C Rotary compressor Upflow air delivery UP FLOW Inverter driven compressor INVERTER Downflow air delivery DOWN FLOW Compressor without oil lubrication system OIL FREE Displacement air delivery DISPL CEMENT Frontal air delivery FRONT FLOW R410 refrigerant charge R410 Close loop CLOSE LOOP R134a refrigerant charge R134a R407C refrigerant charge R407C Indoor installation HFO 1234ze refrigerant charge 1234ze Outdoor installation Chilled water feeding CHILLED WTER Split-system machine SPLIT SYSTEM Free-cooling system FREE COOLING Touch screen TOUCH SCREEN fiftycoolyears RCGROUP Sp G_ITC_RCW_8.4 11

12 IT Cooling - Products selection IR CONDITIONERS FOR DT CENTER FOR PERIMETER INSTLLTION NEW NEW NEW INVERTER INVERTER CHILLEDWTER CHILLEDWTER NEXT EVO INV DX Under/Over versions Close control air conditioners equipped with BLDC scroll compressors for matching with remote air cooled condenser. NEXT EVO INV DW Under/Over versions Close control air conditioners equipped with BLDC scroll compressors and built in water cooled condenser. NEXT EVO CW S Under/Over versions Close control air conditioners for chilled water feeding. NEXT EVO CW K Under/Over versions Close control air conditioners for chilled water feeding. series X TYPE NEW NEXT EVO INV DX NEXT EVO INV DW NEW NEXT EVO CW S NEW NEXT EVO CW K NEW 15 NEXT EVO CW S PLUS NEXT EVO CW K PLUS NEW NEW 125 NEXT EVO DX NEW COOLSIDE EVO DX SYSTEM 4 42 COOLSIDE EVO CW COOLROW DX Inv COOLROW CW IR CONDITIONERS FOR DT CENTER FOR IN ROW, IN RCK INSTLLTION INVERTER COOLSIDE EVO DX SYSTEM in row/in rack versions Direct expansion air conditioning system for high density rack and blade servers. CHILLEDWTER COOLSIDE EVO CW in row/in rack versions Chilled water air conditioners for high density rack and blade servers. 12 G_ITC_RCW_8.4 RCGROUP Sp fiftycoolyears

13 NEW NEW NEW NEW IT Cooling - Products selection IR CONDITIONERS FOR DT CENTER FOR PERIMETER INSTLLTION XCOILS CHILLEDWTER CHILLEDWTER NEW SOFTWRE CHILLEDWTER NEXT EVO CW S PLUS Under version Close control air conditioners for chilled water feeding with separate fan section. NEXT EVO CW K PLUS Under version Close control air conditioners for chilled water feeding with separate fan section. NEXT EVO DX Under/Over versions Close control air conditioners equipped with scroll compressors for matching with remote air cooled condenser. X TYPE Under version Close control air conditioners for chilled water feeding main features 182 CHILLED WTER E C DOWN FLOW INVERTER R410 E C UP FLOW DOWN FLOW INVERTER R410 E C UP FLOW DOWN FLOW CHILLED WTER E C UP FLOW DOWN FLOW 172 CHILLED WTER E C UP FLOW DOWN FLOW 225 CHILLED WTER E C DOWN FLOW CHILLED WTER E C DOWN FLOW R410 E C C UP FLOW DOWN FLOW INVERTER R410 E C FRONT FLOW CLOSED LOOP CHILLED WTER E C FRONT FLOW CLOSED LOOP INVERTER R410 E C FRONT FLOW CHILLED WTER E C FRONT FLOW IR CONDITIONERS FOR DT CENTER FOR IN ROW, IN RCK INSTLLTION INVERTER CHILLEDWTER COOLROW DX Inv in row version Direct expansion air conditioners for high density rack and blade servers. COOLROW CW in row version Chilled water air conditioners for high density rack and blade servers fiftycoolyears RCGROUP Sp G_ITC_RCW_8.4 13

14 IT Cooling - Products selection IR CONDITIONERS FOR DT CENTER FOR PERIMETER INSTLLTION NEXT DW Under/Over versions Close control air conditioners equipped with scroll compressors and built in water cooled condenser. NEXT MTR Over version ir conditioners for metrology labs. NEXT DL Displacement air delivery version Close control air conditioners with displacement air delivery. series main features 7 R410 E C C NEXT DW 108 UP FLOW DOWN FLOW NEXT MTR 7 15 R407c E C UP FLOW NEXT DL 8 52 R410 CHILLED WTER E C DISPL CEMENT IR COOLED CONDENSERS DRY COOLERS TEM MTE 12,1 307,0 ir cooled condensers equipped with axial fans. TEM MTE PF 12,1 154,0 ir cooled condensers equipped with plug fans. DRY COOLER 8,3 172,0 Dry coolers equipped with axial fans. DRY COOLER PF 8,8 89,0 Dry coolers equipped with plug fans. 14 G_ITC_RCW_8.4 RCGROUP Sp fiftycoolyears

15 IT Cooling - Products selection IR CONDITIONERS FOR TELECOMMUNICTION UPS48VDC UPS48VDC UPS48VDC UPS48VDC FREECOOLING FREECOOLING FREECOOLING FREECOOLING ENERGY SPLIT Horizontal or vertical air fl ow Split system air conditioners with free-cooling system. MINIPC Horizontal air delivery Packaged air conditioners with free-cooling system for outdoor installation. ENERTEL Under/Over versions Packaged air conditioners with free-cooling system for indoor installation. ENERTEL DL Displacement air delivery Packaged air conditioners with free-cooling system for indoor installation. series main features ENERGY SPLIT 4 15 R407c SPLIT SYSTEM FREE COOLING UPS 48VDC FRONT FLOW MINIPC 4 19 R407c FREE COOLING FRONT FLOW UPS 48VDC ENERTEL 5 15 R407c R134a FREE COOLING UP FLOW DOWN FLOW ENERTEL DL 6 15 R407c R134a FREE COOLING DISPL CEMENT UPS 48VDC MRK 6 9 INVERTER R410 FREE COOLING FRONT FLOW UPS 48VDC INVERTER UPS48VDC FREECOOLING MRK Horizontal air delivery Packaged air conditioners with free-cooling system for outdoor or indoor installation fiftycoolyears RCGROUP Sp G_ITC_RCW_8.4 15

16 Chillers - Products selection IR COOLED LIQUID CHILLERS WITH FREE-COOLING SYSTEM WITH XIL FNS MXIMO FREECOOLING ir cooled liquid chillers with free-cooling system equipped with scroll compressors and axial fans. EGLE FREE FREECOOLING ir cooled liquid chillers with free-cooling system equipped with scroll compressors and axial fans. series MXIMO EGLE FREE GLIDER EVO FREE GLIDER EVO FREE CL UNICO TURBO FL FREE NEW UNICO TURBO FLG FREE MXIMO PF IR COOLED LIQUID CHILLERS WITH FREE-COOLING SYSTEM WITH PLUG FN FREECOOLING MXIMO PF ir cooled liquid chillers with free-cooling system equipped with scroll compressors and plug fan. 16 G_ITC_RCW_8.4 RCGROUP Sp fiftycoolyears

17 Chillers - Products selection IR COOLED LIQUID CHILLERS WITH FREE-COOLING SYSTEM WITH XIL FNS FREECOOLING GLIDER EVO FREE FREECOOLING ir cooled liquid chillers with free-cooling system equipped with screw compressors and axial fans. HIGHEFFICIENCY GLIDER EVO FREE CL ir cooled liquid chillers in -class energy efficiency with free-cooling system equipped with screw compressors and axial fans main features R410 FREE COOLING PLTE E C FREE COOLING R410 PLTE C R134a SHELL C FREE COOLING R134a CLSS SHELL C FREE COOLING CLSS INVERTER OIL FREE R134a FLOODED C MICRO CHNNEL FREE COOLING CLSS INVERTER OIL FREE 1234ze C FLOODED MICRO CHNNEL FREE COOLING R410 FREE COOLING PLTE E C mechanical cooling free cooling IR COOLED LIQUID CHILLERS WITH FREE-COOLING SYSTEM WITH XIL FNS ND CENTRIFUGL OIL-FREE COMPRESSORS NEW LOWGWP INVERTER HIGHEFFICIENCY FREECOOLING INVERTER HIGHEFFICIENCY FREECOOLING HFO1234ze UNICO TURBO FLG FREE LOWNOISE ir cooled liquid chillers in -class energy efficiency equipped with oil-free centrifugal compressors with magnetic levitation bearings, flooded evaporator and microchannel condensing coils. LOWNOISE UNICO TURBO FL FREE ir cooled liquid chillers in -class energy efficiency equipped with oil-free centrifugal compressors with magnetic levitation bearings, flooded evaporator and microchannel condensing coils. refrigerant charge HFO 1234 ze. LOW GWP fiftycoolyears RCGROUP Sp G_ITC_RCW_8.4 17

18 Chillers - Products selection IR COOLED LIQUID CHILLERS WITH XIL FNS ND CENTRIFUGL OIL-FREE COMPRESSORS NEW INVERTER INVERTER LOWGWP LOWNOISE LOWNOISE HFO1234ze HIGHEFFICIENCY HIGHEFFICIENCY UNICO TURBO FLG ir cooled liquid chillers in -class energy efficiency equipped with oil-free centrifugal compressors with magnetic levitation bearings, flooded evaporator and microchannel condensing coils. UNICO TURBO FL ir cooled liquid chillers in -class energy efficiency equipped with oil-free centrifugal compressors with magnetic levitation bearings, flooded evaporator and microchannel condensing coils. refrigerant charge HFO 1234 ze. LOW GWP. series UNICO TURBO FL 280 NEW UNICO TURBO FLG 260 FRIGO TURBO FL 280 NEW FRIGO TURBO FLG 250 FRIGO TURBO K 270, WTER COOLED LIQUID CHILLERS EQUIPPED WITH CENTRIFUGL OIL-FREE COMPRESSORS INVERTER HIGHEFFICIENCY LOWNOISE NEW LOWGWP HFO1234ze INVERTER HIGHEFFICIENCY LOWNOISE FRIGO TURBO FL Water cooled liquid chillers equipped with -class energy efficiency equipped with oil-free centrifugal compressors with magnetic levitation bearings and flooded evaporator. FRIGO TURBO FLG Water cooled liquid chillers equipped with -class energy efficiency equipped with oil-free centrifugal compressors with magnetic levitation bearings and flooded evaporator. refrigerant charge HFO 1234 ze. LOW GWP. 18 G_ITC_RCW_8.4 RCGROUP Sp fiftycoolyears

19 Chillers - Products selection main features CLSS INVERTER OIL FREE R134a FLOODED C MICRO CHNNEL 1300 CLSS INVERTER OIL FREE 1234ze C FLOODED MICRO CHNNEL 1840 CLSS INVERTER OIL FREE R134a FLOODED 1240 CLSS INVERTER OIL FREE 1234ze FLOODED INVERTER OIL FREE R134a PLTE cooling heat recovery WTER COOLED LIQUID CHILLERS EQUIPPED WITH CENTRIFUGL OIL-FREE COMPRESSORS INVERTER LOWNOISE FRIGO TURBO K Water cooled liquid chillers equipped with oil-free centrifugal compressor with magnetic levitation bearings and plate type heat exchanger fiftycoolyears RCGROUP Sp G_ITC_RCW_8.4 19

20 RC Group software SOFTWRE RCWORLD RCSPECTRUM RC WORLD RC GROUP products selection software. SPECTRUM RC GROUP energy performance estimation software for chillers and heat pumps COOLNET SEQUENCER COOLNET Intelligent NET for IT cooling that maximizes the energy saving in LOD SHRING SEQUENCER Sequencer for chillers, heat pumps and multifunction units RC CLOUD PLTFORM RC CLOUD PLTFORM Performance and quality remote monitoring. GPRS solution for unattended monitoring. 20 G_ITC_RCW_8.4 RCGROUP Sp fiftycoolyears

21 RC Group for IT Cooling COOLING CPCITY CONTROL ON SUPPLY IR TEMPERTURE The latest electronic devices require cold air entering from the front and hot air exit from the back allowing to create hot and cold aisles in Data Center, instead of keeping uniform temperature in the area. for THE PRECISION IR CONDITIONING S MIN PPLICTION: DT CENTER Data Center represents the precision air conditioning s main and most widespread application. In the latest years we witnessed the increase of data processing and the resulting growth in dimensions and energy consumption. The current financial and economical heavy crisis started at the beginning of the XXI century has dramatically highlighted the issue of energy efficiencies and environmental sustainability. The current Data Center managers showed great awareness towards this matter and transmitted their needs to suppliers. The message has been acknowledged by the whole industry: the precision air conditioning has been able to provide the most suitable answers to the needs of systems with increasingly higher energy efficiency coming from designers and current Data Center managers. These pages has the aim to inform about and update the technology state of the art, to furnish details on the methods, the indexes and the institutions of classification and certification and to provide a view of RC Group s products series and systems for the current high efficiency Data Center. TECHNOLOGY STTE OF THE RT From the beginning of the XXI century, industry has provided air conditioning systems and liquid chillers manufacturers with a new generation of components which take full advantage of electronics and the new heat exchange technologies to maximize energy efficiency. Nowadays all air conditioning systems by RC Group for Data Center extensively use these components; in detail: plug fans and axial fans equipped with EC brushless motors; scroll compressors with inverter BLDC motors ; oil-free magnetic levitation centrifugal compressors; air to gas microchannel coil heat exchangers; electronic expansion valves; two-way chilled water valves, in standard and pressure independent characterized version; PID microprocessor control systems; load sharing. s for air conditioning, it means to grant a constant cooling air temperature for the equipment (cold aisle temperature), supply air temperature, ranging from 20 C and 24 C, and to accept a return air temperature to the a/c unit (hot aisle temperature) often at 35 C if not higher. The machine selection has to be done firstly considering the needed air flow, and once identified the cabinet size suitable for such air flow, it is possible to proceed with the evaluation using RC World selection software. Energy and economical benefits due to higher working temperatures are clear: DX air conditioners: possibility to work with high evaporating temperatures with EER increasing and resulting machine size reduction; CW air conditioners: possibility to work with higher in/out chilled water temperatures with resulting size reduction and chiller increasing EER. RC Group air conditioners suitable for cooling capacity control based on supply air temperature are the direct expansion units equipped with BLDC inverter compressors and the chilled water units with 2-way valve: NEXT EVO INV DX and DW NEXT EVO CW NEXT EVO CW PLUS COOLSIDE EVO DX SYSTEM COOLSIDE EVO CW COOLROW DX COOLROW CW INVERTER COOLROW DX Inv in row version NEXT EVO CW Under Version The high efficiency achieved by current RC Group air conditioning systems allows to apply them in the latest Data Center that require: cooling capacity control on supply air temperature; uniform load distribution on all machines (load sharing). ll these machines are equipped with the new control system with microprocessor MP.COM whose main features are: Cooling capacity control on supply air temperature set point; Fans speed control on return air temperature or underfloor pressure set point; Dew-point calculation on heat Exchange coil; Serial management of main components fiftycoolyears RCGROUP Sp G_ITC_RCW_8.4 21

22 RC Group for IT Cooling UNIFORM LOD DISTRIBUTION ON LL CHILLED WTER UNITS (LOD SHRING) The electrical EC (Electronically Commutated) motors which equip the chilled water air conditioners NEXT EVO CW and COOLROW CW series have the following two characteristics: 1. possibility to follow exactly thermal load variations; 2. higher energy efficiency at partial loads. The latter point has radically changed stand-by meaning: no longer some machines at 100% and others in stand-by, but all operating machines at a partial load. Energy savings achieved are significant, as the schemes below clearly show. RC Group has developed COOL NET software for the creation of an intelligent NET that optimizes the LOD SHRING, maximizing the energy savings. Example for a plant with nr. 4 NEXT EVO CW 128 E8 4R units for chilled water feeding equipped with EC plug fans (cooling capacity 106 each): DT CENTER INDEXES / CLSSIFICTIONS INDEX PUE/DCIE Data Center energy efficiency is defined by PUE index or by DCiE that compare infrastructure total power installed (IT systems + cooling + protection + backup + miscellaneous), with the power used by IT equipment for data processing et vice versa. PUE (Power Usage Effectiveness) = Infrastructure total power / IT equipment power [/, absolute value]. DCiE (Data Center Infrastructure Efficiency) = IT equipment power / Infrastructure total power [/, percentage]. The PUE or DCiE starting value represents a reference value of energy efficiency and it identifies a test ambient for repeating further measurements. By comparing starting values with the final ones, data centers managers are able to analyse the results of possible initiatives to increase the energy efficiency and/or to evaluate energy indexes in certain working conditions (partial PUE and DCIE). In any time, it is possible to compare engaged power of IT systems with total power used by the infrastructure. Building Load System request No longer 3 machines at 100% and the other in stand-by Provider Infrastructure Total Power Power Switch UPS Battery backup IT Systems Power IT Systems Servers Memory Equipment Cooling Chillers CRC but ctive Stand-by Power Usage Effectiveness - PUE (Source: Green Grid) PUE = Infrastructure Total Power / IT Equipment Power TRDITIONL 100% ir flow: m 3 /h Fans power input: 3,84 x 3 = 11,52 x h/y = h/y LOD SHRING Stand-by PUE DCiE Efficiency level % Very low % Low % Medium % High % Very high Cooling systems represent over 40% of the data center energy consumption and they have an incisive impact on the efficiency level of the data center. Energy consumption Chiller 33% Humidifiers 3% Close Control ir Conditioners 9% IT Systems 30% PDU 5% UPS 18% Switches/generator 1% Lighting 1% 75% ir flow: m3/h Fans power input: 1,62 x 4 = 6,48 x h/y = h/y Load sharing allows an high energy savings even increasing with the increasing of the parzialization. PUE and DCiE indexes are defined by Green Grid ( org/), a consortium of over 175 associates IT all over the world that joins efforts of global industry to reach a measurement system, processes, methods and new technologies standardization to improve and increase the data center and business computing ecosystems energy efficiency. 22 G_ITC_RCW_8.4 RCGROUP Sp fiftycoolyears

23 RC Group for IT Cooling The mission of Green Grid, a no-profit organisation, is to become the major worldwide authority in the field of efficient energy use by working very closely with the final users, technology providers and governments all over the world. mong the methods used to reach such goal we point out data collection and analysis, developing technology evaluation, procedures for the operators development. Nowadays there are still companies without a documented strategy to reduce energy consumption in the data center, even if many agree with the fact that the energy consumption data represent a growing source of concern. Green Grid provides for everyone a forum where IT operators meet to discuss the different options to increase resources efficiency. Solutions and recommendations are regularly published, and some decisions from this forum represent nowadays a sectors standard. In addition to PUE/DCiE, Green Grid is developing other indexes, such as: Carbon Usage Effectiveness (CUE TM ), Water Usage Effectiveness (WUE TM ) Data Center Productivity (DCP TM ) TIER CLSSIFICTION Functional and design features of the data center infrastructure are uniquely defined by TIER classification, developed by Uptime Institute and it is nowadays an international standard. Uptime Institute, founded in 1993, has been a pioneer in creating and promoting a final users community and they made available their own knowledge in order to improve reliability and the 24h availability in the data center and in IT organizations. Uptime Institute has tested and keeps on developing several innovations that have then become standards in the Data Center: hot / cold aisle layout; energy calculation parameters; cost analysis models; double power input specifications; TIER classification for reliability evaluation. There are 4 TIER classes: TIER I: Data Center with single distribution line/network, respectively one for Power and one for Cooling; no redundant component. vailability: 99,671% ( h/year of uninterrupted operation; down time: h/year). TIER II: Data Center with single distribution line/network, respectively one for Power, one for Cooling; redundant components make possible maintenance during operation. vailability: % ( h/year of uninterrupted operation; down time: 28,69 h/year). TIER III: Data Center with multiple distribution line/network, respectively for Power and Cooling and only one is active; redundant components make possible maintenance during operation. vailability: % ( h/year of uninterrupted operation; down time: 1.58 h/year). TIER IV: Data Center with multiple distribution line/network respectively for Power and cooling, all active with redundant components. Possibility of maintenance during operation and fault tolerance. ll cooling systems, chillers e HVC, have double power supply. vailability: % ( h/year of uninterrupted operation: down time: 0.44 h/year). Nowadays, more than 100 Uptime Institute network members exchange information and suggestions, and along with Uptime Institute itself, they can take part in conferences, sites tours etc... reserved to members only. mong Uptime Institute main activities, addressed to companies and professionals dealing with data center, we point out: education, publishing, seminars, certifications, technical consultancy and others CLSS TIER I TIER II TIER III TIER IV ctive components to support the IT load; Redundancy N=needed; only the active components required to support the IT load, no redundancy N+1=needed +1 active component in addition to those required to support the IT load, 1 redundant component. N+1=needed +1 component in addition to those required to support the IT load, 1 redundant component. N after any failure = availability of all active components necessary to support the IT load after any fault Networks / distribution systems for power and cooling Single network/system Single network/system Dual network / system, one active and the second in standby Dual network / system both active Maintenance during operation No No Yes Yes Single fault tolerance No No No Yes Partitioning No No No Yes Continuous cooling ccording to the thermal load ccording to the thermal load ccording to the thermal load Yes ( Class) vailability 99,671% ( h / year of operation without interruptions) 99,741% ( h / year of operation without interruptions) 99,982% ( h / year of operation without interruptions) 99,995% ( h / year of operation without interruptions) Stop time h/year h/year 1.58 h/year 0.44 h/year Sources: Uptime institute, - Green Grid, fiftycoolyears RCGROUP Sp G_ITC_RCW_8.4 23

24 RC Group for IT Cooling RC GROUP PROPOSL FOR HIGH EFFICIENCY DT CENTER The following pages show the RC Group proposal for high efficiency data center: Data Center with high loads Data Center with medium-low loads Data Center with hot spots DT CENTER WITH HIGH LODS The solution providing the highest energy efficiency is represented by a chilled water system consisting of: Indoor air conditioner: - NEXT EVO CW series (6,2 151 ) with EC plug fans, two-way chilled water valve, temperature control on both air supply and return; - NEXT EVO CW PLUS series ( ) with the same characteristics of the NEXT EVO CW series but with separate fan section. 24 NEXT EVO CW Under Version Liquid chillers: - With very high energy efficiency: UNICO TURBO FL series ( ) in class energy efficiency, equipped with EC axial fans (option), oil free centrifugal compressors with magnetic levitation bearings, shell and tube type flooded evaporator and microchannel condensing coils. UNICO TURBO FL - With free-cooling section: UNICO TURBO FL FREE series ( ) in class energy efficiency, with EC axial fans (option), oil free centrifugal compressors with magnetic levitation bearings, shell and tube type flooded evaporator, microchannel condensing coil and Cu/l condensing coils. GLIDER EVO FREE series ( ) equipped with EC axial fans (option) and screw compressors with modulating capacity control, dry expansion shell and tube evaporator, condensing and free-cooling coil contained in single coil Cu/l; GLIDER EVO FREE CL series GLIDER EVO FREE ( ) with the same characteristics of the GLIDER EVO FREE series, but in class energy efficiency. Energy analysis is needed to choose the most suitable chiller. SPECTRUM, RC Group energy performance estimation software for chillers is available for this purpose. TECHNICL SYNERGY RC Group proposes itself as the sole supplier by offering both air conditioning units and liquid chillers. This offers the opportunity to reduce at minimum the time designated by the customers for the units selection, avoiding cross-searches within various direct or indirect manufacturers. Furthermore this characteristic offers the possibility to have an accurate energy analysis for what concerns the energy consumption of the selected system and the relative obtainable energy savings. PCKGED LIQUID CHILLERS These units are characterized by a complete set of components that reduce installation times and cost. Main switch with door lock safety, electric motor thermal protection, refrigerant charge and LN connection are supplied as standard. PCKGED FREE-COOLING LIQUID CHILLERS These units have the same characteristics of the packaged liquid UNICO TURBO FL FREE chillers but are characterized by an integrated free-cooling system that includes the heat exchanger coils, the free-cooling valve and the relative pipes connection. This solution allows for high floor space savings and for reduction of the hydraulic plant realization cost. CLSS ENERGY EFFICIENCY ll chillers shown are available in class energy efficiency with EER up to 3,60 in mechanical working conditions. Furthermore, the control software of these units, developed by RC Group, are designed to maximize the energy savings and to manage the chiller/air conditioner system according to the current temperature control standards for these technological ambients. HIGH COOLING DENSITY up to 72,0 /m 2 B NEXT EVO CW precision air conditioners with traditional constructive system take place beside NEXT EVO CW PLUS precision air conditioners that, thanks to an optimization work on components and optional accessories, grant high density of cooling in those situations where the space management is a fundamental design target as important as performance is. The air conditioning unit is divided in two sections: the upper part ( part in the picture) includes the high efficiency air filters and the air handling section with a cooling coil available in 4,6,8 rows version; the lower part (B part in the figure) can be installed in an underfloor compartment and includes the plug-fan section. The lower section can be supplied with adjustable floor-stand (optional accessory) that allows the adjustment of the frame height to reach the floor level. NEXT EVO CW PLUS Under Version G_ITC_RCW_8.4 RCGROUP Sp fiftycoolyears

25 RC Group for IT Cooling DT CENTER WITH MEDIUM/LOW LODS DT CENTER WITH HOT SPOTS The solution providing the highest energy efficiency is represented by a direct expansion system consisting of: Close control air conditioners NEXT EVO INV DX (7,3 102 ) equipped with EC plug fans and scroll compressors BLDC inverter, temperature control on both air supply and return; Remote air condensers TEM MTE with axial fans or TEM MTE PF with EC type plug fans. With appropriate site weather conditions, it is possible to achieve energy efficiency even higher thanks to a direct expansion system with a free-cooling section (option) consisting of: Close control air conditioners NEXT EVO INV DW (7,3 102) with FREE- COOLING section, EC plug fans and scroll compressors BLDC inverter, temperature control on both air supply and return NEXT EVO INV Over Version Remote DRY COOLER with axial fans and DRY COOLER PF with EC type plug fans; Pumping group with free-cooling valve. The solution providing the highest energy efficiency is represented by COOLSIDE EVO DX SYSTEM with direct expansion for in-row/in-rack installation consisting in: Indoor evaporating unit COOLSIDE EVO (4,5 53,1 ) with EC type plug-fans in row version (for application hot aisle/cold aisle or in rack version, for a close loop air delivery/discharge all inside the rack, temperature sensor on air delivery and return; Outdoor motocondensing unit MCI with scroll compressor BLDC inverter, EC axial fans, micro channel condensing coils. Possibility to match up to three indoor evaporating units to single outdoor motocondensing unit. MONO SPLIT MCI 10 DX 10 MULTI SPLIT MCI 40 DX 10 DX 10 DX 10 COOLSIDE EVO DX SYSTEM BOX SERVER RCK optional accessory is a standard type 19 server rack. Matched with COOLSIDE EVO DX form a complete solution for small data center ( IN RCK solution with air delivery directly inside the rack). COOLSIDE EVO CW series for chilled water feeding is also available. One of the main features of NEXT EVO INV series is the high energy efficiency both at design conditions and at partial load conditions that are variable during the year. The units are equipped with inverter driven scroll compressors granting a proportional control on supplied cooling power, while the fans are matched to EC brushless type electric motors with built-in electronic commutation system. These motors grant high performances with minimum energy consumption and total absence of electromagnetic noise. dditional energy savings can be reach with an air return plenum with Free cooling damper for direct free-cooling (option) fiftycoolyears RCGROUP Sp G_ITC_RCW_8.4 25

26 RC Group for IT Cooling OTHER PRECISION IR CONDITIONING PPLICTIONS Despite signs of saturation, especially in Europe, Telecommunications (TLC) keep on representing the second market for close control air conditioning after Data Center. It is possible to divide the market in: FIXED TELECOMMUNICTION: telephone rooms are comparable to traditional small/medium Data Center now equipped with perimeter machines with temperature control and return air and without hot/cold aisle logic. ll current precision conditioners series by RC Group can be used for telephone rooms air conditioning; a pay-back time evaluation is needed in case of high efficiency units with or without free-cooling. MOBILE TELECOMMUNICTION: containers and small mobile telecommunication stations use small precision air conditioning, from 5 up. 20, all equipped with free-cooling section. Series available: TYLOR-MDE SERVICE BY RC GROUP Innovation, flexibility and timing, are some of the successful features in precision air conditioning. The last two play an important role in taking the most ambitious projects. Despite a wide standard products series for models numbers and multifunctions features, not all Users needs can be satisfied. In these cases RC Group, with its high skilled team, is willing to implement changes on current products or to manufacture ad hoc products for a particular installation. Thanks to taylor-made service, RC Group meant to create a virtuous circle with users/consultants and agents/distributors with a continuous exchange of requests/information leading to the creation of a suitable product and to customer loyalty. Packaged air conditioners for outdoor installation (MINIPC and MRK for outdoor installation); Packaged air conditioners for indoor installation (ENERTEL and MRK for indoor installation); Split conditioners with outdoor motocondensing (ENERGY SPLIT). CONSULTNTS CUSTOMERS MRK ir conditioner for telecommunication DISTRIBUTOR INFORMTION OTHER CLOSE CONTROL IR CONDITIONING PPLICTIONS: Power rooms Measurement rooms Radar rooms CT rooms (Computed xial Tomography) NMR rooms (Nuclear Magnetic Resonance) Control rooms UPS rooms (Uninterruptible Power Supply) Battery room Transformers rooms Many ad hoc requests have then been developed and now they are included in machine standard equipment. The taylor-made service, available for chillers and air conditioners, has represented RC Group trump card in taking projects of large Data Centers of important International Banks, TLC Operators, cloud computing owners. Most of installations need the use of a limited number of close control air conditioning, so all current RC Group series can be used. The direct expansion solution is the most suitable, if we consider heat load to be dissipated, but the incidental availability of chilled water used for other rooms with higher heat load makes convenient the installation of chilled water air precision conditioning. This is the case of power/ups/battery/trafo rooms of large Data Centers using the same CHW close control air conditioners widely installed in Data Halls. nother interesting opportunity belongs to seasonal availability of chilled water for summer air conditioning in the offices; in this case the best solution is represented by direct expansion machines with one additional coil (extracircuit EC) fed by chilled water from chiller and not needed for offices. Conditioner will use chilled water coil in hot season; compressors is stand-by and it works if needed and when chiller stops. lso in all of these cases, a pay-back time evaluation is necessary. 26 G_ITC_RCW_8.4 RCGROUP Sp fiftycoolyears

27 Highlights ELECTRONIC EXPNSION VLVES The electronic expansion valves have many benefits. They grant a higher energy efficiency combined with a better stability of the system. IT COOLING EFFICIENT ENERGY USE One of the main features of RC Group air conditioning series is the high energy efficiency both in design conditions and in partial load conditions that are variable conditions during the year. BLDC INVERTER SCROLL COMPRESSORS The compressor driven by an inverter varies the load continuously and the regulation of the refrigerant circuit can be easily adapted, without oscillations and transients, to the operating conditions required. The system is highly efficient since it is supplying the energy necessary to satisfy the required thermal load only; INVERTER furthermore it is possible to supply thermal or cooling energy even in case of overload conditions of the system. The working range of scroll compressors in comparison to the nominal values of cooling and thermal capacity output, varies on average from 35% to 120%, for centrifugal compressors varies instead on average from 20% to 110%. The possibility to follow regularly and progressively the refrigeration load, excluding on-off sequences of the compressor, allows to realize the heating/ cooling hydronic plant even without the use of the inertial tank. FETURES Capacity modulation No need for power factor correction Minimum starting current (LR) bility to follow punctually and progressively the thermal load BENEFITS More Energy Efficiency (eliminating start/stop cycles) Minimum energy consumption High efficiency at partial thermal loads High performances, Higher EER and ESEER Essential feature to achieve the, + energy class Total absence of electromagnetic noise. Quieter than standard compressor MICROPROCESSOR CONTROL SYSTEM Microprocessor control system for the management and monitoring of the working and alarm statuses. The system includes: Voltage free contact for general alarm. Main components hour meter, with programmed maintenance intervention. Data logger integrated function for the events and alarms recording. Flash memory for the data storage in case of lack of power supply. Menu management with protection password. FETURES High capacity modulation Precision control Wide range of operation bility to follow punctually plant demand and environmental condition change Better use of compressors Bi-directional flow BENEFITS Energy saving Better stability of the system, combined with inverter driven compressors Replace the operation of two traditional expansion valves in reverse cycle heat pumps FNS WITH BRUSHLESS TYPE EC MOTOR The fans electric motors are the brushless type with built-in electronic commutation system (EC) which yield high energy savings during operation in reduced air flow. These electric motors are ensuring high performances, minimum energy consumption and total absence of electromagnetic noise. (%) 100 Engaged power C motor EC motor (% RPM) Motor rotation speed EC MOTORS FETURES Synchronous brushless motor Integrated electronic commutated system High efficiency (83-86%) Minimum power input Stepless rotation speed control with 0-10VDC proportional signal No electromagnetic noise fiftycoolyears RCGROUP Sp G_ITC_RCW_8.4 27

28 Highlights PLUG FNS FETURES High discharge head centrifugal fans installed on chillers for indoor installation Impeller in composite material, P6 plastic reinforced with glass-fibre, exempt from rust formation. FREE COOLING FREECOOLING The free-cooling system is an important accessory that allows you to maximize energy savings of air conditioning plant. The microprocessor controls a dual source free-cooling system: direct freecooling with direct introduction into the room of ambient air, or water indirect free-cooling with a dedicated heat exchanger. BENEFITS Dramatic reduction in power required The power required decreases with the reduction of power motor revolutions More efficient than traditional motor verage energy saving of 30% Longer lifetime (no brush and commutation erosion) Reduction of electromagnetic interference Minimal noise emission ccording to the set-point and the energy saving logic the controller activates a more affordable free-cooling system. VILBLE VERSIONS RC Group air conditioners are available in Over, Under and Displacement versions UP-FLOW IR DELIVERY (OVER) The air distribution goes from the top of the unit directly in to the room. The air flow in each area is predetermined during the design stage and it is not dependent on the actual state of the load to be dissipated. The system is normally applied in Comfort plants and in those plants having a defined low/medium room thermal loads density. DOWN-FLOW IR DELIVERY (UNDER) The air distribution goes from the bottom through the plenum between the building floor and the raised floor. This solution is usually applied in Hi-Tech room air conditioning and it is most favourable when load is uniformly distributed in all the areas of the room. DISPLCEMENT IR DELIVERY (DL) The air-conditioning system with displacement air delivery is based on the principle that the air is distributed at a very low speed, while enabling a cooling effect by convection. Every electronic equipment will absorb the amount of cold required to maintain a correct temperature level inside, through a natural convection effect. The greater is the load inside the electronic equipment, the greater is this effect. Therefore, every electronic equipment uses only the amount required to dissipate its own thermal load, which is generated by maximising the result and the energy efficiency of the system. FETURES Free cooling is a cooling technique that allows the shutdown of the compressors when the outside temperatures are low, producing a considerable reduction in electric consumption for the air conditioning system. The indirect free cooling system consists in the partial or complete cooling of the chilled water of the existing cooling system with the outside air. The direct free cooling system consists in the direct entry of the outside air into the room, if the outside air has a lower temperature than indoor air. BENEFITS Energy saving. The longer the outside temperature remains below the required temperature for cooling, higher the energy saving. HORIZONTL IR DELIVERY Cooling system for rows of racks (hot/cold aisle or in-row). Units are placed in the rows of racks that are arranged to obtain alternate cold and hot aisles. Electronic equipment contained in racks manage independently to aspire the necessary air for cooling. Cooling system for shelter. The units distribute the air inside the shelter cooling the electronic equipment directly. Different kind of air conditioners with air delivery in the upper part of shelter, ceiling level, or in the lower part of the shelter, floor level are available. mobile telecommunication air conditioner s direct free-cooling damper 28 G_ITC_RCW_8.4 RCGROUP Sp fiftycoolyears

29 Highlights N EFFICIENT ENERGY USE One of the most important characteristics of TURBO FL chillers is their high energy efficiency and consequently high ESEER values, both at design and at the various operating conditions experienced during the year. The diagram compare the EER curves of TURBO FL with centrifugal compressors vs. screw compressors. The considerable improvement of the centrifugal unit under all load conditions is well illustrated. The following charts have been prepared in accordance with EUROVENT standards. Therefore, the air and water temperatures specified by these standards have been considered at partial load. EER [/] 7,5 7,0 6,5 6,0 5,5 5,0 4,5 4,0 3,5 3,0 ir cooled liquid chiller UNICO TURBO FL SCREW CHILLER 25% 50% 75% 100% Cooling Load 13,0 12,0 11,0 10,0 9,0 8,0 7,0 6,0 5,0 4,0 FRIGO TURBO FL SCREW CHILLER 25% 50% 75% 100% MGNETIC LEVITTION CENTRIFUGL COMPRESSOR DIRECTLY DRIVEN BY BUILT-IN INVERTER The TURBO FL liquid chillers are equipped with two-stage centrifugal compressor with variable speed, which is able to follow punctually plant demands, obtaining values of energy efficiency ratio (EER) growing in a narrowing of the cooling load. The compressors of the TURBO FL liquid chillers are equipped with magnetic levitation oil-free bearings which compared to traditional ball bearings, completely eliminate all the maintenance procedures of lubrication. INVERTER NO NEED OF POWER FCTOR CORRECTION The power factor of the centrifugal compressor (cos-ϕ) is always close to unity under all load conditions. This does not require the use of any power factor correction capacitors. MINIMUM STRTING CURRENT (LR) The compressors built-in inverter system is able to limit the starting current for each compressor to 5 mpere. Other types of compressors having the same capacity can produce starting currents up to hundreds of mpere. This low inrush current prevents any voltage fluctuation on the mains. Start-up transients are negligible and without any negative effect on the connected equipment (lighting systems, computer, electric- medical instruments etc.). INVERTER SYSTEM The compressor driven by an inverter varies the load continuously and the regulation of the refrigerant circuit can be easily adapted, without oscillations and transients, the operating conditions required. The system is highly efficient since it is supplying the energy necessary to satisfy the required thermal load only; furthermore it is possible to supply thermal or cooling energy even in case of overload conditions of the system. The working range, in comparison to the nominal values of cooling capacity output, varies on average from 20% to 110%. QUIET OPERTION TURBO FL machines are also extremely quiet. This promotes their use in noise sensitive locations such as old city centres, hotels, offices and residential buildings. EER [/] Water cooled liquid chiller Cooling Load RELIBILITY With their reliable operation the TURBO FL series is well suited for every application from comfort cooling, through the high-tech industrial sector and especially mission critical strategic applications (like hospitals, clean rooms, web farms, data centres, telecommunication exchanges, air-traffic control centres). Their operating reliability is guaranteed 24 hours/day for 365 days/year. FLOODED EVPORTOR The TURBO FL liquid chillers are equipped with flooded evaporator, where the refrigerant in the evaporation phase is outside of the tube bundle. This heat exchange solution allows to obtain a greater energy efficiency of the system because it reduces the differential between the refrigerant expansion temperature and the liquid cooled temperature. Moreover the circulation of the liquid inside the tubes of the heat exchanger can be varied considerably in relation to the cooling load, reducing the energy engaged by the pumping system. CLSS ENERGY EFFICIENCY The best and most accurate components applied to the chillers grants high energy efficiency with EER higher than 3,1 for air cooled units and even higher than 5,05 for water cooled units. This values satisfy the Eurovent conditions to join the energy efficiency class. HIGHEFFICIENCY CLSS GLYCOL FREE SYSTEM The accessory allows to use pure water instead of antifreeze solutions in the hydraulic circuit of the plant. This accessory is factory assembled and it don t modify the machine dimensions. n intermediate heat exchanger divides the hydraulic circuit into two parts; one part includes the chiller with the Glycol-Free hydraulic circuit with Free- Cooling coils and the centrifugal pump. The other part includes the evaporator and the plant hydraulic circuit. The Glycol-Free hydraulic system (free-cooling coil and centrifugal pump) must be filled with an antifreeze solution having a concentration suitable to the operation conditions of the machine, while the plant hydraulic system will be filled with pure water. GLYCOLFREE LOW NOISE EMISSIONS RC Group allows to select the units, not only for the required cooling capacity, but even for the units environmental acoustic impact. This allows to answer to the law requirements against noise. Two kits for the reduction of the noise emissions are available: LNO kit, for a noise reduction ELN kit, for an extreme noise reduction PUMPING GROUPS RC Group propose a complete sets of optional accessories for chilled water pumping. To satisfy different plant needs are available pumping groups with one, two, three pumps with low, medium and high discharge heads. LOWNOISE fiftycoolyears RCGROUP Sp G_ITC_RCW_8.4 29

30 GO GREEN solutions GOGREEN solutions RELIBLE The rtificial Intelligence of RC Group goes green with SPECTRUM, software able to turn a simple technical selection in a projection into the future, by allowing the choice of the most environmentally friendly and more economical solution. Thanks to RC Cloud Platform, the most modern form of remote control, the product reliability is always guaranteed. 30 GOGREEN solutions THE EFFICIENT ENERGY USE Today, environmental respect is the core value and guideline to develop new technologies. The environmental sustainability makes its appearance in every sector through research techniques for the renewal of the resources of our planet Earth. Mankind has the duty to defend and preserve the delicate balance of the Earth. Sustainability for RC Group is the commitment of the present generations to leave to future generations the same quantity and quality of resources especially. Since 1997 (from the Kyoto Protocol) to today, the first aspect is the reduction of global warming, gradually limiting the use of HCFC refrigerants and, later, of F gases as well.. The high efficiency of the products together with the study and design of tailored solution, translate into energy savings, and consequently in cost reduction. RC Group solutions arise from synergies between RC Group hardware and software, through analysis and energy management. Calculating it in advance and carefully, drive us to system design compatible with requirements and environment. t the same time, we can also determine which will be the return of the initial investment in terms of economies of exercise.. It is thanks to his experience that RC Group has been able to integrate and merge the design excellence that distinguishes it for years, with the needs of the environment. The result is a series of solutions arising from the study on efficient energy use: GOGREEN solutions RC GROUP products and solutions for the high efficiency air conditioning for Data Center, Telephone exchangers, Server Farm and in all applications where are required affability of operation, continuous operation and high energy efficiency. ECOLOGIC The focus on the latest regulations in the field of environmental sustainability and energy saving, led RC Group to adopt refrigerants with low environmental impact, making its products, as well as efficient, even friends of the environment. EVOLVED lways in step with the continuous and rapid technological developments, RC Group uses the best components and cutting-edge techniques and tools, such as compressors driven by Inverter and software for the selection and management of the facilities. NTURL s pioneer of Free-Cooling technology since the early eighties and still not for everyone, RC Group has always placed an emphasis on the development of this technique. nother system at the base of energy-saving is the Glycol- Free, which allows the use of pure water instead of antifreeze solutions. GO Reliable Ecologic Evolved Natural LIGHT WEIGHT SOLUTION FOR ENVIRONMENT Environmentally. Energy Saving. Eco-sustainability. RC Group makes use of refrigerants innocuous to the atmosphere, first of all the hydrofluoroolefin HFO1234ze that, thanks to its high environmental compatibility joined to a high energy efficiency, results to be an excellent SOLUTION for replacement of R134a. nother point in its favor is the much higher critical temperature which allows to operate at much higher condensation temperatures retaining a good thermodynamic efficiency. LOWGWP NOODP LOWTEWI HFO1234ze G_ITC_RCW_8.4 RCGROUP Sp fiftycoolyears

31 IT cooling start here

32 GOGREEN solutions RC Group makes use of refrigerants innocuous to the atmosphere, first of all HFO1234ze that, thanks to its high environmental compatibility joined to a high energy efficiency, results to be an excellent SOLUTION for replacement of R134a. RC Group liquid chillers with HFO1234ze refrigerant charge: HFO1234ze UNICO TURBO FLG pg:167 UNICO TURBO FLG FREE pg:157 FRIGO TURBO FLG pg:175 RC GROUP products and solutions for the high efficiency air conditioning for Data Center, Telephone exchangers, Server Farm and in all applications where are required affability of operation, continuous operation and high energy efficiency. The continuous research of RC Group has developed a precision air conditioners with uniques and innovative features: X TYPE. X Type pg:33 32

33 X Type X Type: Close control air conditioners for chilled water feeding with down-flow air delivery. Cooling Capacity: CHILLEDWTER XCOILS HIGHEFFICIENCY COOLNET GOGREEN solutions X Type rcgroupairconditioning CHILLED WTER E C DOWN FLOW MIN FETURES Chilled water feeding precision air conditioner. 4 models, 2 versions available. Machine designed according to a CFD analysis (Computational Fluid Dynamics). Chilled water feeding. Operation with ΔT10 C. X Type heat exchangers. SHR ratio = 1. EER up to 80. Variable air flow. Variable water flow. Two-way chilled water valve. Cooling density up to 47,6 /m 2. Downflow UNDER air delivery. Suitable for indoor installation. MIN BENEFITS Technical synergy with RC Group liquid chillers. New plug fans with EC electric motors and composite impeller of the latest generation, which guarantees a reduction of power consumption (ERP 2015 certification). Improvement of the control software, developed by RC Group, with advanced control logic. Bag filters of large surface that reduce replacement operations to once a year. Panels fully removable to facilitate the operations of extraordinary maintenance; Software dvanced : intelligent NET for IT Cooling, that maximizes the energy saving in LOD SHRING (on request).shring (a richiesta). Complete set of optional accessories: filters, plenum, panels, stand. INDOOR INSTLLTION The machines are designed for indoor installation. LIMITI DI FUNZIONMENTO Deviations, even in small quantities, by the nominal operating conditions ir return conditions: 35 C 30%rH ir delivery temperature: 25 C Chilled water inlet temperature: 18 C Chilled water outlet temperature: 28 C require a verification of the unit to the new working conditions. For operating conditions different than the nominal, please contact your local gent or the RC Group Sales Department to verify your requirements and provide the solution for your system fiftycoolyears RCGROUP Sp G_ITC_RCW8.4 33

34 X Type GOGREEN solutions IT Cooling MIN COMPONENTS FNS SECTION The section is divided into several boxes each containing its own fan with safety net. The boxes are to be installed and assembled on site in the void of the raised floor, creating the foundation on which will be based the air handling section. Frame in galvanized steel sheet with protective surfaces treatment in compliance with UNI ISO 9227/STMB117 and ISO 7253, and painted with epoxy powders. Colour RL 7016 hammered; Height adjusting rubber holders. Centrifugal fans with backward curved blades with wing profile, single suction and without scroll housings (Plug-fans), directly coupled to external rotor electric motor. - Impeller in composite material exempt from rust formation. - Brushless type synchronous EC motor with integrated electronic commutated system and continuous variation of the rotation speed. The motor rotation control is obtained with the EC system (Electronic Commutation) that manage the motor according to the signal coming from the microprocessor control. Fan guard on air delivery. Connecting cables with the unit electrical panel for power and control signals for fan motors. Fans control through ModBus. Supports for the tiles of the raised floor. The supports are adjustable in height to adapt to the thickness of the tiles. FILTERS SECTION The section is divided into several boxes, each containing two bag filters removable from the unit front. The boxes are to be installed and assembled on site over the air handling section. Disposable bag filters with G4 efficiency, with cells in synthetic fibre and metallic frame (EN ). - Filters are not rigenerable. - The high filtering surface ensures a year of operation before replacement. CONTROL SYSTEM Microprocessor control system with graphic display for control and monitor of operating and alarms status. The system includes: Built-in clock for alarms date and time displaying and storing; Built-in memory for the storing of the intervened events (up to 100 events recorded); Predisposition for connectivity board housing ( RCcom MBUS/JBUS, LON, BCnet for Ethernet (SNMP- TCP/IP), BCnet for MS/TP). The electronic cards are optional accessories; Main components hour-meter; Non-volatile Flash memory for data storage in case of power supply faulty; Menu with protection password; LN connection (max 15 units). IR HNDLING SECTION Packaged section is that includes the heat exchanger, the electric panel and water flow control valves. The section is longer than the underlying fan section to allow the transit of the hydraulic pipes and electric cables for power and control. Base and top frame in extruded aluminium, painted with epoxy powders. Colour RL 9005; Panels in galvanized steel sheet with protective surfaces treatment in compliance with UNI ISO 9227/STMB117 and ISO 7253, and painted with epoxy powders. Colour RL 7016 hammered; Panels insulated with polyurethane foam and seals to ensure air tight. X type heat exchanger coil with 2 cooling stage with copper tubes and high efficiency aluminium fins, specifically developed to provide high heat transfer and lower air side and water side pressure drops. Frame in galvanized steel. Condensate tray in peralluman with PVC flexible discharge pipe. Compartment for hydraulic section on the right side of the unit and containing 2-way motorized valve for water flow regulation with 0 10 VDC control actuator and emergency manual control. Temperature sensors on air intake and air delivery with control, regulation and limitation functions. Temperature sensor on chilled water inlet / outlet. Hydraulic pipes Hydraulic connections on the right side of the unit Compartment for electrical panel on the right side of the unit with panel. Electrical panel in accordance with EN norms, suitable for indoor installation, complete with: External panel Internal panel on which are located the controls and safety devices Main switch with door lock safety Magnetothermic switches for supply fans. The supply fans equipped with EC electric motor don t require contactors. Transformer for auxiliary circuit and microprocessor supply. Connecting cables for power and control signals for fan motors. Power supply 400/3/50+N. Terminals: OUTLETS - Voltage free deviating contact for General larm 1 - Voltage free contact for supply fans status. INLETS - Emergency unit stop with signalling on display (external alarm). - External enabling. 34 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

35 IT Cooling OPTIONL CCESSORIES X Type Pressure independent two way motorized valve Dual power supply 1022-Telaio di sostegno 0-400mm Sandwich panels Disposal M5 efficiency air filter Disposal M6 efficiency air filter Disposal F7 efficiency air filter Motorized damper with frame Differential pressure air control Clogged filters alarm Water presence alarm dditional water sensor (kit) 1020-External main switch T/rH sensor on air return T/rH external sensor T/rH remote sensor RC-Com MBUS/JBUS Serial board LON Serial board BCnet Ethernet - SNMP - TCP/IP Serial board BCnet MS/TP Serial board Emergency microprocessor supply Remote terminal shared Kit modem GSM Plantwatch without modem Remote graphic terminal kit SOFTWRE DVNCED - COOLNET RC CLOUD PLTFORM GOGREEN solutions T1 S T2 S T3 S T4 S X Type available accessory; - not available accessory HYDRULIC / ERULIC DIGRM HYDRULIC DIGRM ERULIC DIGRM 35 C M1 T1 23 C HE CFD nalysis T2 T3 T4 PF 18 C 28 C 25 C LEGEND M1 2-way motorized valve for mail coil HE Main coil PF Plug Fan T1 ir return temperature probe Plug Fan speed control T2 ir supply temperature probe M1 valve control T3 Chilled water inlet temperature probe T4 Chilled water outlet temperature probe fiftycoolyears RCGROUP Sp G_ITC_RCW8.4 35

36 X Type GOGREEN solutions IT Cooling TECHNICL DT - X Type MODEL COOLING CPCITY (1) Total Sensible SHR / Power input EER (1) Plug fans EC n. ir flow m 3 /h Nominal external static pressure Pa Max external static pressure Pa "X" Type cooling coil Water flow rate m 3 /h Pressure drop - coil + valve kpa ir filters n. Efficiency Filtering surface m 2 Power supply V/Ph/Hz Max unit operating current (FL) Sound level - ISO 3744 (2) On air delivery On air intake On front side Net weight Net weight ir handling section Net weight Filters section Net weight Fans section Connections Water inlet/outlet - ISO 7/1 - R Ø Condensate discharge Rubber pipe F Ø T1 S T2 S T3 S T4 S 52,4 99,2 141,0 182,0 52,4 99,2 141,0 182, ,2 2,9 4,5 6,2 43,31 33,97 31,06 29, ,5 8,6 12,2 15, G4 G4 G4 G4 11,8 17,6 23,5 29,4 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 4,4 8,7 13,1 17,4 74,2 75,7 76,8 77,7 63,1 67,2 68, , ,4 62, /2" 2" 2" 2+1/2" 1/2" 1/2" 1/2" 1/2" THE COOLING CPCITY DOES NOT CONSIDER THE SUPPLY FN MOTOR THERML LOD 1. Characteristics referred to entering air at 35 C - 30%RH; chilled water temperature C - 0% glycol 2. Noise level at 1 meter in free field. DIMENSIONS (mm) XT1 XT2 XT3 XT4 a b c d XT XT XT XT c a d b 36 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

37 NEXT EVO INV DX NEXT EVO INV DX: Close control air conditioners, equipped with BLDC inverter scroll compressors. Cooling Capacity: INVERTER ECFN NEXT EVO INV DX INVERTER rcgroupairconditioning R410 E C UP FLOW DOWN FLOW MIN FETURES Direct expansion precision air conditioner. 13 models available, 2 versions for a wide selection opportunity. Modulating cooling capacity control. EER up to 4,82. BLCD inverter and on/off scroll compressors. Single and double refrigerant circuit. R410 Refrigerant charge. EC plug-fans. OVER and UNDER versions. Suitable for indoor installation. MIN BENEFITS Units with single and double refrigerant circuits. vailability of remote condensers with axial fans (TEM MTE series) and with plug fans (TEM MTE PF series). High EER. High efficiency at partial load. vailability of electric heater. vailability of steam humidifier. vailability of hot water heating coil. vailability of extra circuit heating coil. Complete set of optional accessories: filters, plenum, panels, stand. Easily of maintenance. INDOOR INSTLLTION The machines are designed for indoor installation. REMOTE CONDENSER The units are designed to be matched with remote condensers with axial fans (TEM MTE series) or plug-fans (TEM MTE PF series). WORKING LIMITS Room air temperature: 14 C minimum temperature with wet bulb. 24 C maximum temperature with wet bulb. 35 C maximum temperature with dry bulb. Room air humidity: 20%RH minimum relative humidity. 75%RH maximum relative humidity fiftycoolyears RCGROUP Sp G_ITC_RCW8.4 37

38 NEXT EVO INV DX MIN COMPONENTS FRMEWORK Base in aluminium extrusion, painted with epoxy powders. Frame in galvanized steel sheet. Galvanized steel sheet panels painted with epoxy powders, internally insulated with noise absorption material and seals to ensure air tight with the panels. Hinged front panels with quick release removal system. Total front access for routine maintenance. Removable lateral and back side panels. Colour: RL 9005 for base and frame (black) RL7016 for panels (anthracite gray) OVER version - ir intake from the front through honeycomb type grille and air delivery from the top. - Washable air pre-filters with G2 efficiency, with cells in synthetic fibre (size E0 excluded). UNDER version Machine size E0 - ir intake from the front through honeycomb type grille and air delivery from the bottom. Machine size E1, E2, E3, E4, E5, E6, E7, E8, E9 - ir intake from the top and air delivery from the bottom. INVERTER DRIVEN COMPRESSORS scroll compressor BLDC inverter with spiral profile optimized for R410 refrigerant. Synchronous brushless inverter driven motor. Inverter for modulating capacity control. Reactance for the reduction of electromagnetic noise and interference. Crankcase heater. Rubber supports. Soundproof cap. ON / OFF COMPRESSORS scroll compressors with spiral profile optimized for R410 refrigerant. 2-pole 3-phase electric motor with direct on line starting. Crankcase heater. Rubber supports. Soundproof cap. FILTER SECTION Machine size E0 Washable air filters with G2 efficiency, with cells in synthetic fibre and metallic frame (EN ). Machines size E1, E2, E3, E4, E5, E6, E7, E8, E9 Washable air filters with G4 efficiency, with cells in synthetic fibre and metallic frame (EN ). EVPORTING SECTION Heat exchanger coil with internally corrugated copper tubes and high efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops. Finned pack with hydrophilic treatment that assure the condensate water drop, high thermal conductivity and does not favour the growth of microorganisms. Frame in galvanized steel. Condensate tray in peraluman with PVC flexible discharge pipe. IT Cooling FNS SECTION Centrifugal fans with backward curved blades with wing profile, single suction and without scroll housings (Plug-fans), directly coupled to external rotor electric motor. - Impeller in composite material, P6 plastic reinforced with glass-fibre, exempt from rust formation. - Brushless type synchronous EC motor with integrated electronic commutated system and continuous variation of the rotation speed. The motor rotation control is obtained with the EC system (Electronic Commutation) that manage the motor according to the signal coming from the microprocessor control. Fans control through ModBus. Temperature sensors on air intake and air delivery with control, regulation and limitation functions. Fan guard with rubber support (UNDER version) REFRIGERNT CIRCUIT Components for each refrigerant circuit: Electronic expansion valve. Sight glass. Filter dryer on liquid line. Pressure transducers with indication, control and protection functions, on low and high refrigerant pressure. High pressure safety switch with manual reset. Liquid receiver with accessories. Refrigerant circuit with copper tubing with anticondensate insulation of the suction line. Plastic capillary hoses for pressure sensors connection. R410 refrigerant charge and lubricant oil type PVE (Polyvinyl ether). Valves on gas delivery and liquid return for coupling to remote air cooled condenser. 0 10V proportional signal to manage the condensing control system of the remote air cooled condenser. Oil separator on gas discharge. ELECTRICL PNEL In accordance with EN norms complete with: Main switch with door lock safety. Magnetothermic switches for fans. Magnetothermic switches for compressors. Contactors for each load. The inverter driven compressors and the EC fans don t require contactors. Transformer for auxiliary circuit and microprocessor supply. Terminals: OUTLETS - Voltage free deviating contact for General larm 1 - Voltage free contact for machine operating status. INLETS - Emergency unit stop with signalling on display (external alarm). - External enabling. Power supply 400/3/50+N CONTROL SYSTEM Microprocessor system with graphic display for control and monitor of operating and alarms status. The system includes: - Real time clock. - Predisposition for connectivity board housing ( RCcom MBUS/JBUS, LON, BCnet for Ethernet (SNMP- TCP/IP), BCnet for MS/TP). - Main components hour-meter. - Nonvolatile Flash memory for data storage in case of power supply faulty and for alarms status recording (2MB). - Menu with protection password. - LN connection. 38 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

39 IT Cooling NEXT EVO INV DX COMMON OPTIONL CCESSORIES NEXT EVO INV DX TEM MTE remote condenser TEM MTE PF remote condenser Team Mate electrical power supply by internal unit Floor stand Hmax=350 mm Floor stand Hmax=450 mm Floor stand Hmax=510 mm Disposal F5 efficiency air filter ir supply plenum with F6 filters ir supply plenum with F7 filters ir supply plenum with F9 filters ir supply plenum with sound absorber 945 -ir return plenum with Free Cooling damper ir supply plenum with 5 closed sides Sandwich panels Motorized damper with frame Extra-Circuit system Steam humidifier Dehumification system Electric heater Increased electrical heater Water heater + 2 way valve Differential pressure air control Clogged filters alarm Water presence alarm dditional water sensor (kit) T/rH sensor on air return T/rH external sensor T/rH remote sensor Contact enabling the smoke / fire 83 - Compressor operation indicator RC-Com MBUS/JBUS Serial board LON Serial board BCnet Ethernet - SNMP - TCP/IP Serial board BCnet MS/TP Serial board Double serial interface Emergency microprocessor supply Dual power supply Remote terminal shared Remote graphic terminal kit Kit modem GSM Plantwatch without modem RC CLOUD PLTFORM OPTIONL CCESSORIES - OVER VERSION ONLY NEXT EVO INV DX Condensate discharge system (kit) Blind frontal pannel ir discharge plenum with grilles Plenum with frontal grille and sound absorber coustic panel Incresed umidifier OPTIONL CCESSORIES - OVER VERSION ONLY NEXT EVO INV DX Condensate discharge system (kit) Condensate discharge system Incresed umidifier S M1 S M1 S M1 S M1 S M1 S M2 S M2 S M3 S M3 D M2 D M2 D M4 D M4 E0 E1 E2 E3 E4 E4 E5 E5 E6 E5 E7 E8 E available accessory; - not available accessory S M1 S M1 S M1 S M1 S M1 S M2 S M2 S M3 S M3 D M2 D M2 D M4 D M4 E0 E1 E2 E3 E4 E4 E5 E5 E6 E5 E7 E8 E available accessory; - not available accessory S M1 S M1 S M1 S M1 S M1 S M2 S M2 S M3 S M3 D M2 D M2 D M4 D M4 E0 E1 E2 E3 E4 E4 E5 E5 E6 E5 E7 E8 E available accessory; - not available accessory TO BE MTCHED WITH REMOTE CONDENSER The units are designed to be matched with remote condensers with axial fans (TEM MTE series) or plug-fans (TEM MTE PF series). TEM MTE TEM MTE PF fiftycoolyears RCGROUP Sp G_ITC_RCW8.4 39

40 NEXT EVO INV DX N EFFICIENT ENERGY USE The project NEXT EVO INV uses the current best technologies aimed at energy saving for an extremely efficient use of energy as scroll compressors BLDC inverter and EC supply fans. In detail: IT Cooling CONTROL OF THE COOLING CPCITY CCORDING TO IR DELIVERY TEMPERTURE The cooling capacity control is made on the air delivery temperature. COOLING SECTION Units are equipped with scroll compressors BLDC inverter that allow a modulating cooling capacity. Thermal load Cooling capacity The scroll compressor BLDC Inverter can change the load continuously and the regulation of the refrigerant circuit can be easily adapted, without oscillations and transients, to the operating conditions required. The system is highly efficient because it is supplying only the energy necessary to satisfy the required thermal load; furthermore the system can supply cooling capacity even in case of overload conditions. Models with double refrigerant circuit (D version) are equipped with one scroll compressor BLDC inverter for each refrigerant circuit. This solution ensures extreme precision in the delivery of the cooling capacity required, together with a drastic reduction of power input from the compressors. The exchanger finned coils of large surface is provided with fins with hydrophilic treatment that guarantees optimum falling water of condensation, high thermal conductivity and prevents the development of micro-organisms. Models with double refrigerant circuit (D version) are equipped with interlaced finned coil that maximizes the heat exchange in the operating condition with a single cooling circuit, cancelling the by-pass effect on the exchanger. Cut off threshold IR FLOW CONTROL CCORDING TO IR RETURN TEMPERTURE The EC plug fans modulate the air flow using as variable the distance from the temperature set point. It s possible to define the minimum and maximum air flow through dedicated parameters in order to adjusting the operation of the unit to the needs of the plant. In addition to the probe positioned on the machine, you can install the accessory remote probe to be placed in the environment to influence the most critical point of the system In case of no demand of cooling / heating, the control logic provides that the fans ensure a minimum air flow necessary to the probes to obtain a correct reading of the ambient temperature. Moreover in only dehumidification demand condition, the microprocessor control reduce the air flow to obtain the maximum dehumidification effect. ir flow Setpoint ir flow ir delivery temperature ( C) FN SECTION The Plug fans of the air handling section of the NEXT EVO INV series are directly coupled to brushless type electric motors with built-in electronic commutation system (EC) and driven by microprocessor control via MODBus; this allows a unit operation with variable air flow. Heating Setpoint Heating request differential Cooling request differential Cooling Setpoint Return temperature ( C) These EC electric motors ensuring high performances, minimum energy consumption and total absence of electromagnetic noise. The management software of the machine, specifically developed by RC Group for their precision air conditioners, allowing the better management of the system machine with a modulating logic of ventilation, cooling performances and the accessory system of direct free-cooling. CONTROL LOGIC ND OPERTION The logic PID of the microprocessor enables simultaneous control of cooling performances as a function of air delivery temperature and the air flow as a function of air return temperature or pressure in the underfloor / duct. re therefore possible following two control logics LOGIC 1 Cooling performance control as a function of air delivery temperature and of the air flow as a function of the return temperature. LOGIC 2 Cooling performance control as a function of the air delivery temperature and the air flow as a function of the underfloor / duct pressure. Follow the detailed description of the control logic. IR FLOW CONTROL S FUNCTION OF THE UNDERFLOOR OR DUCTING PRESSURE (optional accessory) The EC plug fans modulate the air flow using as variable the distance of a signal from the set point, coming from a differential pressure transmitter (optional) with pressure outlet via plastic tubing, to install underfloor or in the duct. It s possible to define the minimum and maximum air flow through dedicated parameters in order to adjusting the operation of the unit to the needs of the plant. Setpoint ir flow Differential pressure (Pa) DIRECT FREE-COOLING SYSTEM (optional accessory) The control system also manages the operation of the air conditioner equipped with a plenum for DIRECT FREE-COOLING (optional), that allows free cooling in the environment to be conditioned, directly entering outdoor air. The accessory is fully modulating and ensures a drastic reduction of power consumption of the machine, avoiding the start of the compressors. The use of this accessory includes the installation of an overpressure damper into the room to allow for the expulsion of excess air. 40 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

41 IT Cooling NEXT EVO INV DX GRPHIC FOR UNITS SELECTION This graph allows you to select the model as a function of cooling capacity and its EER. The EER values include the remote condenser series TEM MTE. SINGLE REFRIGERNT CIRCUIT 5,0 028 NEXT EVO INV DX S M1 5,5 Characteristic referred to entering air at 24 C-50%rH; condensing temperature 50 C NEXT EVO INV DX S M2 4,5 5, , , ,0 3,5 3,5 3, , Cooling Capacity - 2, Cooling Capacity - 2, ,5 NEXT EVO INV DX S M3 5, ,5 4,0 3,5 3, , Cooling Capacity DOUBLE REFRIGERNT CIRCUIT 5,5 5,5 NEXT EVO INV DX D M2 080 Characteristic referred to entering air at 24 C-50%rH; condensing temperature 50 C NEXT EVO INV DX D M4 5, , ,5 4,5 4,0 4,0 3,5 3,5 3, , Cooling Capacity - Cooling Capacity- 2,5 2, fiftycoolyears RCGROUP Sp G_ITC_RCW8.4 41

42 NEXT EVO INV DX TECHNICL DT MODEL COOLING CPCITY (1) Total Sensible SHR / Over (*) Under (*) Supply fans n. ir flow m 3 /h Nominal external static pressure Over Pa Nominal external static pressure Under Pa Fans max external static pressure Pa Scroll compressors BLCD inverter type n. On/Off type n. Cooling capacity control ir filters n. Efficiency Refrigerant Refrigerant charge (2) Gas circuits n. Power supply (**) Max operating current (FL) Unit starting current (LR) Energy efficiency indexes (1) EER Over (1) (*) / EER Under (1) (*) / Sound pressure level - ISO 3744 (3) On air delivery Over On air delivery Under On air intake Over Irradiated Over On air intake Under On front side Under Net weight Over Net weight Under Remote condenser (4) TEM MTE (*) n. x Mod. TEM MTE PF n. x Mod. Refrigerant connections Gas delivery ODS Ø Liquid return ODS Ø Hydraulic connections - Condensate discharge F Ø MODEL COOLING CPCITY (1) Total Sensible SHR / Over (*) Under (*) Supply fans n. ir flow m 3 /h Nominal external static pressure Over Pa Nominal external static pressure Under Pa Fans max external static pressure Pa Scroll compressors BLCD inverter type n. On/Off type n. Cooling capacity control ir filters n. Efficiency Refrigerant Refrigerant charge (2) Gas circuits n. Power supply (**) Max operating current (FL) Unit starting current (LR) Energy efficiency indexes (1) EER Over (1) (*) / EER Under (1) (*) / Sound pressure level - ISO 3744 (3) On air delivery Over On air delivery Under On air intake Over Irradiated Over On air intake Under On front side Under Net weight Over Net weight Under Remote condenser (4) TEM MTE (*) n. x Mod. TEM MTE PF n. x Mod. Refrigerant connections Gas delivery ODS Ø Liquid return ODS Ø Hydraulic connections - Condensate discharge F Ø 42 IT Cooling 007 S M1 010 S M1 016 S M1 020 S M1 E0 E1 E2 E3 min nom max min nom max min nom max min nom max 7,3 8,5 9,5 8,7 11,6 17,3 13,5 18,0 21,3 15,2 22,5 31,0 6,5 7,0 7,6 8,7 10,3 13,3 13,4 16,4 18,1 15,2 21,3 26,6 0,88 0,83 0,80 1,00 0,89 0,77 0,99 0,91 0,85 1,00 0,95 0,86 1,98 2,69 3,45 2,18 3,45 8,01 3,67 6,00 8,39 3,63 6,74 12,76 1,98 2,69 3,45 2,17 3,44 8,01 3,63 5,94 8,32 3,57 6,68 12, Mod. Mod. Mod. Mod G2 G4 G4 G4 R410 R410 R410 R410 2,5 2,8 3,1 3, /3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 7,2 18,0 25,8 28,4 4,2 5,2 5,7 8,2 3,69 3,17 2,75 4,00 3,36 2,16 3,68 3,00 2,54 4,19 3,34 2,43 3,69 3,17 2,75 4,02 3,37 2,16 3,72 3,03 2,56 4,26 3,37 2,44 51,0 51,0 51,0 58,4 58,4 58,4 61,1 63,3 63,3 61,1 62,9 64,9 51,0 51,0 51,0 58,2 58,2 58,2 60,6 63,0 63,0 60,8 62,6 64,7 45,1 45,1 45,1 47,3 47,3 47,3 49,5 51,1 51,1 49,5 50,8 52,3 35,0 35,0 35,0 40,3 40,3 40,3 43,0 45,2 45,2 43,0 44,8 46,8 45,1 45,1 45,1 49,9 49,9 49,9 52,3 54,5 54,5 52,4 54,2 56,1 45,1 45,1 45,1 40,5 40,5 40,5 42,9 45,1 45,1 43,0 44,8 46, xM11 1xM20 1xM25 1xM35 1xT11 1xT21 1xT24 1xT /2" 1/2" 1/2" 1/2" 028 S M1 034 S M2 040 S M2 053 S M3 E4 E4 E5 E5 min nom max min nom max min nom max min nom max 16,7 28,1 37,0 16,9 35,0 50,2 16,8 40,8 52,9 17,0 54,2 69,1 16,7 28,1 37,0 16,9 35,0 45,5 16,8 40,8 52,7 17,0 53,0 60,3 1,00 1,00 1,00 1,00 1,00 0,91 1,00 1,00 1,00 1,00 0,98 0,87 3,80 8,17 13,75 4,03 9,97 19,53 3,71 11,93 20,19 4,13 15,94 24,42 3,64 7,94 13,36 3,87 9,64 19,16 3,63 11,83 20,04 4,05 15,76 24, Mod. Mod. Mod. Mod G4 G4 G4 G4 R410 R410 R410 R410 4,9 5,2 7,5 7, /3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 28,6 42,3 46,6 60,3 8,3 67,1 71,2 84,3 4,39 3,44 2,69 4,19 3,51 2,57 4,53 3,42 2,62 4,12 3,40 2,83 4,59 3,54 2,77 4,37 3,63 2,62 4,63 3,45 2,64 4,20 3,44 2,85 59,4 64,1 69,3 59,4 67,1 69,3 53,0 66,1 70,7 53,0 70,7 70,7 57,7 62,8 68,2 57,7 65,9 68,2 52,1 66,0 70,6 52,1 70,6 70,6 48,5 51,7 56,2 49,6 54,5 56,3 47,8 53,7 57,6 48,7 57,7 57,7 41,3 46,0 51,2 41,5 49,0 51,2 37,0 48,0 52,6 37,5 52,6 52,6 49,7 54,3 59,6 50,0 57,5 59,6 46,3 57,5 62,0 46,8 62,0 62,0 40,3 44,9 50,2 40,7 48,0 50,2 37,2 48,1 52,6 37,7 52,6 52, xM45 1xM60 1 x M 60 1 x M 95 1xT44 1xT58 1 x T 69 1 x T /2" 1/2" 1/2" 1/2" G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

43 IT Cooling TECHNICL DT MODEL COOLING CPCITY (1) Total Sensible SHR / Over (*) Under (*) Supply fans n. ir flow m 3 /h Nominal external static pressure Over Pa Nominal external static pressure Under Pa Fans max external static pressure Pa Scroll compressors BLCD inverter type n. On/Off type n. Cooling capacity control ir filters n. Efficiency Refrigerant Refrigerant charge (2) Gas circuits n. Power supply (**) Max operating current (FL) Unit starting current (LR) Energy efficiency indexes (1) EER Over (1) (*) / EER Under (1) (*) / Sound pressure level - ISO 3744 (3) On air delivery Over On air delivery Under On air intake Over Irradiated Over On air intake Under On front side Under Net weight Over Net weight Under Remote condenser (4) TEM MTE (*) n. x Mod. TEM MTE PF n. x Mod. Refrigerant connections Gas delivery ODS Ø Liquid return ODS Ø Hydraulic connections - Condensate discharge F Ø NEXT EVO INV DX 057 S M3 040 D M2 065 D M2 080 D M4 E6 E5 E7 E8 min nom max min nom max min nom max min nom max 17,7 60,6 71,4 19,0 38,2 42,8 29,6 62,5 69,3 25,1 77,1 81,3 17,7 59,7 65,3 19,0 38,2 42,8 28,6 62,5 69,3 25,0 77,1 80,2 1,00 0,99 0,91 1,00 1,00 1,00 0,97 1,00 1,00 1,00 1,00 0,99 4,22 18,36 24,97 4,07 14,31 18,69 6,24 21,78 27,28 5,52 27,54 30,80 4,13 18,20 24,79 3,99 14,15 18,53 6,14 21,55 27,07 5,43 27,34 30, Mod. Mod. Mod. Mod G4 G4 G4 G4 R410 R410 R410 R410 8,2 8, /3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 60,9 42,8 61,3 73,2 84,8 14,4 16,6 147,3 4,19 3,30 2,86 4,67 2,67 2,29 4,74 2,87 2,54 4,55 2,80 2,64 4,29 3,33 2,88 4,76 2,7 2,31 4,82 2,9 2,56 4,62 2,82 2,66 50,8 67,8 67,8 53,0 66,1 69,3 49,8 67,2 68,3 51,2 73,3 73,3 50,3 67,9 67,9 52,1 66,0 69,2 47,8 67,0 68,2 49,7 73,2 73,2 48,5 55,3 55,3 47,4 53,6 56,3 48,4 54,7 55,7 47,1 60,1 60,1 36,7 49,7 49,7 36,7 48,0 51,2 36,4 49,1 50,2 35,9 55,2 55,2 46,1 59,3 59,3 46,8 57,5 60,6 45,4 58,5 59,6 44,9 64,6 64,6 37,0 49,9 49,9 37,7 48,1 51,2 36,4 49,1 50,2 35,9 55,1 55, x M 95 2 x M 20 2 x M 35 2 x M 45 1 x T 86 2 x T 21 2 x T 33 2 x T /2" 1/2" 1/2" 1/2" MODEL COOLING CPCITY (1) Total Sensible SHR / Over (*) Under (*) Supply fans n. ir flow m 3 /h Nominal external static pressure Over Pa Nominal external static pressure Under Pa Fans max external static pressure Pa Scroll compressors BLCD inverter type n. On/Off type n. Cooling capacity control ir filters n. Efficiency Refrigerant Refrigerant charge (2) Gas circuits n. Power supply (**) Max operating current (FL) Unit starting current (LR) Energy efficiency indexes (1) EER Over (1) (*) / EER Under (1) (*) / Sound pressure level - ISO 3744 (3) On air delivery Over On air delivery Under On air intake Over Irradiated Over On air intake Under On front side Under Net weight Over Net weight Under Remote condenser (4) TEM MTE (*) n. x Mod. TEM MTE PF n. x Mod. Refrigerant connections Gas delivery ODS Ø Liquid return ODS Ø Hydraulic connections - Condensate discharge F Ø 100 D M4 E9 min nom max 30,5 96,8 102,0 29,3 96,1 99,5 0,96 0,99 0,98 7,04 36,25 41,30 6,96 35,99 40, Mod. 6 G4 R410 15, /3/50+N 92,3 164,3 4,33 2,67 2,47 4,38 2,69 2,49 45,5 70,9 70,9 43,5 71,0 71,0 48,2 58,2 58,2 35,8 52,8 52,8 44,6 62,4 62,4 35,8 53,0 53, x M 50 2 x T /2" THE COOLING CPCITY DOES NOT CONSIDER THE SUPPLY FN MOTOR THERML LOD 1. Characteristics referred to entering air at 24 C-50%RH; 35 C ambient temperature. 2. Unit refrigerant charge. Remote condenser, connections pipes and optional are excluded. 3. Noise level at 1 meter in free field (external static pressure at nominal conditions) 4. For matching to other remote air cooled condensers please refer to RC WORLD selection program (*) The value includes the TEM MTE remote condenser shown in the table. (**) The remote condenser has separated power supply. Please refer to TEM MTE and TEM MTE PF chapters fiftycoolyears RCGROUP Sp G_ITC_RCW8.4 43

44 NEXT EVO INV DX TECHNICL DT - OPTIONL CCESSORIES NEXT EVO INV DX Electric heater Capacity Capacity steps n. Humidifier Steam capacity /h Power input Extra circuit coil (1) Total cooling capacity Sensible cooling capacity Heating coil (2) Heating capacity IT Cooling S M1 S M1 S M1 S M1 S M1 S M2 S M2 S M3 S M3 D M2 D M2 D M4 D M4 E0 E1 E2 E3 E4 E4 E5 E5 E6 E5 E7 E8 E9 2,5 5,1 5,1 6,0 9,0 9,0 13,5 13,5 13,5 13,5 13,5 18,0 18, ,4 2,3 2,3 2,3 6,0 6,0 6,0 6,0 6,0 6,0 11,3 11,3 11,3-11,0 18,1 24,7 39,0 43,3 55,4 64,2 69,5 63,3 94,2 117,0 135,0-10,0 16,5 22,4 35,4 39,4 49,7 59,0 63,3 52,5 80,0 98,3 115,0-24,1 36,2 50,5 81,4 89,8 109,0 126,0 148,0 109,0 160,0 193,0 232,0 THE COOLING/HETING CPCITY DOES NOT CONSIDER THE SUPPLY FN MOTOR THERML LOD ccessories technical data are referred to nominal conditions. 1. Characteristics referred to entering air at 24 C 50%RH with chiller water at 7/12,5 C and 0% glycol 2. Characteristics referred to entering air at 20 C with hot water at 75/60 C DIMENSIONS (mm) a b c E E E E E E E E E E c a b 44 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

45 NEXT EVO INV DW NEXT EVO INV DW: Close control air conditioners, equipped with built in water cooled condenser and BLDC inverter scroll compressors. Cooling Capacity: INVERTER ECFN NEXT EVO INV DW INVERTER rcgroupairconditioning R410 E C UP FLOW DOWN FLOW MIN FETURES Direct expansion precision air conditioner. 13 models available, 2 versions for a wide selection opportunity. Modulating cooling capacity control. EER up to 7,33. BLCD inverter and on/off scroll compressors. Built-in water cooled condenser. Single and double refrigerant circuit. R410 Refrigerant charge. EC plug-fans. OVER and UNDER versions. Suitable for indoor installation. MIN BENEFITS Units with single and double refrigerant circuits. vailability of remote condensers with axial fans (TEM MTE series) and with plug fans (TEM MTE PF series). High EER. High efficiency at partial load. vailability of electric heater. vailability of steam humidifier. vailability of hot water heating coil. vailability of extra circuit heating coil. vailability of indirect free-cooling coil, esigned to be matched with DRY COOLER series with axial fans or DRY COOLER PF series with plugfans. Complete set of optional accessories: filters, plenum, panels, stand. Easily of maintenance. INDOOR INSTLLTION The machines are designed for indoor installation. BUILT IN WTER COOLED CONDENSER Water temperature: 30/50 C Outlet temperature range. WORKING LIMITS Room air temperature: 14 C minimum temperature with wet bulb. 24 C maximum temperature with wet bulb. 35 C maximum temperature with dry bulb. Room air humidity: 20%RH minimum relative humidity. 75%RH maximum relative humidity fiftycoolyears RCGROUP Sp G_ITC_RCW8.4 45

46 NEXT EVO INV DW MIN COMPONENTS FRMEWORK Base in aluminium extrusion, painted with epoxy powders. Frame in galvanized steel sheet. Galvanized steel sheet panels painted with epoxy powders, internally insulated with noise absorption material and seals to ensure air tight with the panels. Hinged front panels with quick release removal system. Total front access for routine maintenance. Removable lateral and back side panels. Colour: RL 9005 for base and frame (black) RL7016 for panels (anthracite gray) OVER version - ir intake from the front through honeycomb type grille and air delivery from the top. - Washable air pre-filters with G2 efficiency, with cells in synthetic fibre (size E0 excluded). UNDER version Machine size E0 - ir intake from the front through honeycomb type grille and air delivery from the bottom. Machine size E1, E2, E3, E4L, E5L, E6L, E7L, E8L, E9L. - ir intake from the top and air delivery from the bottom. INVERTER DRIVEN COMPRESSORS scroll compressor BLDC inverter with spiral profile optimized for R410 refrigerant. Synchronous brushless inverter driven motor. Inverter for modulating capacity control. Reactance for the reduction of electromagnetic noise and interference. Crankcase heater. Rubber supports. Soundproof cap. ON / OFF COMPRESSORS scroll compressors with spiral profile optimized for R410 refrigerant. 2-pole 3-phase electric motor with direct on line starting. Crankcase heater. Rubber supports. Soundproof cap. FILTER SECTION Machine size E0 Washable air filters with G2 efficiency, with cells in synthetic fibre and metallic frame (EN ). Machines size E1, E2, E3, E4L, E5L, E6L, E7L, E8L, E9L. Washable air filters with G4 efficiency, with cells in synthetic fibre and metallic frame (EN ). IT Cooling REFRIGERNT CIRCUIT Components for each refrigerant circuit: Electronic expansion valve. Sight glass. Filter dryer on liquid line. Pressure transducers with indication, control and protection functions, on low and high refrigerant pressure. High pressure safety switch with manual reset. Liquid receiver with accessories. Refrigerant circuit with copper tubing with anticondensate insulation of the suction line. Plastic capillary hoses for pressure sensors connection. R410 refrigerant charge and lubricant oil type PVE (Polyvinyl ether). Oil separator on gas discharge. ELECTRICL PNEL In accordance with EN norms complete with: Main switch with door lock safety. Magnetothermic switches for fans. Magnetothermic switches for compressors. Contactors for each load. The inverter driven compressors and the EC fans don t require contactors. Transformer for auxiliary circuit and microprocessor supply. Terminals: OUTLETS - Voltage free deviating contact for General larm 1 - Voltage free contact for machine operating status. INLETS - Emergency unit stop with signalling on display (external alarm). - External enabling. Power supply 400/3/50+N CONTROL SYSTEM Microprocessor system with graphic display for control and monitor of operating and alarms status. The system includes: - Real time clock. - Predisposition for connectivity board housing ( RCcom MBUS/JBUS, LON, BCnet for Ethernet (SNMP- TCP/IP), BCnet for MS/TP). - Main components hour-meter. - Nonvolatile Flash memory for data storage in case of power supply faulty and for alarms status recording (2MB). - Menu with protection password. - LN connection. EVPORTING SECTION Heat exchanger coil with internally corrugated copper tubes and high efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops. Finned pack with hydrophilic treatment that assure the condensate water drop, high thermal conductivity and does not favour the growth of microorganisms. Frame in galvanized steel. Condensate tray in peraluman with PVC flexible discharge pipe. CONDENSING SECTION Copper brazed plate type with cover plates, plates and connections in ISI 316 stainless steel. 0 10V proportional signal to manage the condensing control system. FNS SECTION Centrifugal fans with backward curved blades with wing profile, single suction and without scroll housings (Plug-fans), directly coupled to external rotor electric motor. - Impeller in composite material, P6 plastic reinforced with glass-fibre, exempt from rust formation. - Brushless type synchronous EC motor with integrated electronic commutated system and continuous variation of the rotation speed. The motor rotation control is obtained with the EC system (Electronic Commutation) that manage the motor according to the signal coming from the microprocessor control. Fans control through ModBus. Temperature sensors on air intake and air delivery with control, regulation and limitation functions. Fan guard with rubber support (UNDER version) 46 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

47 IT Cooling NEXT EVO INV DW COMMON OPTIONL CCESSORIES NEXT EVO INV DW DRY COOLER DRY COOLER PF Free Cooling System FC Water regulating valve Floor stand Hmax=350 mm Floor stand Hmax=450 mm Floor stand Hmax=510 mm Disposal F5 efficiency air filter ir supply plenum with F6 filters ir supply plenum with F7 filters ir supply plenum with F9 filters ir supply plenum with sound absorber 945 -ir return plenum with Free Cooling damper ir supply plenum with 5 closed sides Sandwich panels Motorized damper with frame Extra-Circuit system Steam humidifier Dehumification system Electric heater Increased electrical heater Water heater + 2 way valve Differential pressure air control Clogged filters alarm Water presence alarm dditional water sensor (kit) T/rH sensor on air return T/rH external sensor T/rH remote sensor Contact enabling the smoke / fire 83 - Compressor operation indicator RC-Com MBUS/JBUS Serial board LON Serial board BCnet Ethernet - SNMP - TCP/IP Serial board BCnet MS/TP Serial board Double serial interface Emergency microprocessor supply Dual power supply Remote terminal shared Remote graphic terminal kit Kit modem GSM Plantwatch without modem RC CLOUD PLTFORM M1 M1 M1 M1 M1 M2 M2 M3 M3 D M2 D M2 D M4 D M4 E0 E1 E2 E3 E4L E4L E5L E5L E6L E5L E7L E8L E9L available accessory; - not available accessory OPTIONL CCESSORIES - UNDER VERSION ONLY NEXT EVO INV DW Condensate discharge system (kit) Blind frontal pannel ir discharge plenum with grilles Plenum with frontal grille and sound absorber coustic panel Incresed umidifier S M1 S M1 S M1 S M1 S M1 S M2 S M2 S M3 S M3 D M11 D M11 D M22 D M22 E0 E1 E2 E3 E4 E4 E5 E5 E6 E5 E7 E8 E available accessory; - not available accessory OPTIONL CCESSORIES - UNDER VERSION ONLY NEXT EVO INV DW Condensate discharge system (kit) Condensate discharge system Incresed umidifier S M1 S M1 S M1 S M1 S M1 S M2 S M2 S M3 S M3 D M11 D M11 D M22 D M22 E0 E1 E2 E3 E4 E4 E5 E5 E6 E5 E7 E8 E available accessory; - not available accessory fiftycoolyears RCGROUP Sp G_ITC_RCW8.4 47

48 NEXT EVO INV DW N EFFICIENT ENERGY USE The project NEXT EVO INV uses the current best technologies aimed at energy saving for an extremely efficient use of energy as scroll compressors BLDC inverter and EC supply fans. In detail: IT Cooling CONTROL OF THE COOLING CPCITY CCORDING TO IR DELIVERY TEMPERTURE The cooling capacity control is made on the air delivery temperature. COOLING SECTION Units are equipped with scroll compressors BLDC inverter that allow a modulating cooling capacity. Thermal load Cooling capacity The scroll compressor BLDC Inverter can change the load continuously and the regulation of the refrigerant circuit can be easily adapted, without oscillations and transients, to the operating conditions required. The system is highly efficient because it is supplying only the energy necessary to satisfy the required thermal load; furthermore the system can supply cooling capacity even in case of overload conditions. Models with double refrigerant circuit (D version) are equipped with one scroll compressor BLDC inverter for each refrigerant circuit. This solution ensures extreme precision in the delivery of the cooling capacity required, together with a drastic reduction of power input from the compressors. The exchanger finned coils of large surface is provided with fins with hydrophilic treatment that guarantees optimum falling water of condensation, high thermal conductivity and prevents the development of micro-organisms. Models with double refrigerant circuit (D version) are equipped with interlaced finned coil that maximizes the heat exchange in the operating condition with a single cooling circuit, cancelling the by-pass effect on the exchanger. Cut off threshold IR FLOW CONTROL CCORDING TO IR RETURN TEMPERTURE The EC plug fans modulate the air flow using as variable the distance from the temperature set point. It s possible to define the minimum and maximum air flow through dedicated parameters in order to adjusting the operation of the unit to the needs of the plant. In addition to the probe positioned on the machine, you can install the accessory remote probe to be placed in the environment to influence the most critical point of the system In case of no demand of cooling / heating, the control logic provides that the fans ensure a minimum air flow necessary to the probes to obtain a correct reading of the ambient temperature. Moreover in only dehumidification demand condition, the microprocessor control reduce the air flow to obtain the maximum dehumidification effect. ir flow Setpoint ir flow ir delivery temperature ( C) FN SECTION The Plug fans of the air handling section of the NEXT EVO INV series are directly coupled to brushless type electric motors with built-in electronic commutation system (EC) and driven by microprocessor control via MODBus; this allows a unit operation with variable air flow. Heating Setpoint Heating request differential Cooling request differential Cooling Setpoint Return temperature ( C) These EC electric motors ensuring high performances, minimum energy consumption and total absence of electromagnetic noise. The management software of the machine, specifically developed by RC Group for their precision air conditioners, allowing the better management of the system machine with a modulating logic of ventilation, cooling performances and the accessory system of direct free-cooling. CONTROL LOGIC ND OPERTION The logic PID of the microprocessor enables simultaneous control of cooling performances as a function of air delivery temperature and the air flow as a function of air return temperature or pressure in the underfloor / duct. re therefore possible following two control logics LOGIC 1 Cooling performance control as a function of air delivery temperature and of the air flow as a function of the return temperature. LOGIC 2 Cooling performance control as a function of the air delivery temperature and the air flow as a function of the underfloor / duct pressure. Follow the detailed description of the control logic. IR FLOW CONTROL S FUNCTION OF THE UNDERFLOOR OR DUCTING PRESSURE (optional accessory) The EC plug fans modulate the air flow using as variable the distance of a signal from the set point, coming from a differential pressure transmitter (optional) with pressure outlet via plastic tubing, to install underfloor or in the duct. It s possible to define the minimum and maximum air flow through dedicated parameters in order to adjusting the operation of the unit to the needs of the plant. Setpoint ir flow Differential pressure (Pa) DIRECT FREE-COOLING SYSTEM (optional accessory) The control system also manages the operation of the air conditioner equipped with a plenum for DIRECT FREE-COOLING (optional), that allows free cooling in the environment to be conditioned, directly entering outdoor air. The accessory is fully modulating and ensures a drastic reduction of power consumption of the machine, avoiding the start of the compressors. The use of this accessory includes the installation of an overpressure damper into the room to allow for the expulsion of excess air. 48 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

49 IT Cooling INDIRECT FREE-COOLING SYSTEM (optional accessory) The control system also manages the operation of the air conditioner equipped with an INDIRECT FREE-COOLING system (optional). This system consists of one water cooling coil with water 2-way proportional valve, condensing control valve. The cooling coil is installed in the return air stream just after the filter section. In this way the air is partially or totally cooled before entering the main cooling coil ensuring a drastic reduction of power consumption of the machine. This working mode can be obtained by integrating the FREE-COOLING system with the water circuit of the DW machine and connecting them to an external dissipation system (option, DRY COOLER series or DRY COOLER PF series) and to a pumping group (PWU, option). NEXT EVO INV DW When ambient temperatures are below 5 C, the FREE-COOLING system is capable of providing total system capacity without having to call for operation of the compressor/s (total free cooling). t ambient temperatures between 5 C and 21 C the FREE-COOLING provides pre-cooling of the handled air, activating the compressor/s only to provide the cooling capacity necessary for the full balance of the room load (partial free cooling). The system is fully managed by the microprocessor control system installed as standard on the unit. GRPHIC FOR UNITS SELECTION This graph allows you to select the model as a function of cooling capacity and its EER. SINGLE REFRIGERNT CIRCUIT Characteristic referred to entering air at 24 C-50%rH; water to the condenser C 7,0 6,5 028 NEXT EVO INV DW S M1 7,0 6, NEXT EVO INV DW S M2 6, ,0 5, ,0 5,5 4,5 4,0 3, ,0 4,5 4, , Cooling Capacity Cooling Capacity - 3, ,5 7, NEXT EVO INV DW S M3 6,5 6,0 5,5 5,0 4,5 4, , Cooling Capacity DOUBLE REFRIGERNT CIRCUIT 7, , ,5 NEXT EVO INV DW D M2 8,5 8,0 7, Characteristic referred to entering air at 24 C-50%rH; water to the condenser C NEXT EVO INV DW D M4 7,0 6,0 6,5 5,5 6,0 5,0 5,5 5,0 4,5 4,5 4, , ,5 Cooling Capacity - 3,5 Cooling Capacity fiftycoolyears RCGROUP Sp G_ITC_RCW8.4 49

50 NEXT EVO INV DW IT Cooling TECHNICL DT MODEL COOLING CPCITY (1) Total Sensible SHR / Over Under Condenser water flow rate m 3 /h Condenser pressure drop kpa Supply fans n. ir flow m 3 /h Nominal external static pressure Over Pa Nominal external static pressure Under Pa Fans max external static pressure Pa Scroll compressors BLCD inverter type n. On/Off type n. Cooling capacity control ir filters n. Efficiency Refrigerant Refrigerant charge (2) Gas circuits n. Power supply (**) Max operating current (FL) Unit starting current (LR) Energy efficiency indexes (1) EER Over (1) / EER Under (1) / Sound pressure level - ISO 3744 (3) On air delivery Over On air delivery Under On air intake Over Irradiated Over On air intake Under On front side Under Net weight Over Net weight Under Connections - ISO 228/1 G Condenser water inlet/outlet M Ø Condensate discharge - Rubber pipe F Ø 007 M1 010 M1 016 M1 020 M1 E0 E1 E2 E3 min nom max min nom max min nom max min nom max 6,3 8,0 9,6 9,2 11,0 20,1 11,4 17,4 24,5 15,8 21,6 35,9 5,8 6,8 7,5 9,1 10,0 14,5 11,4 16,0 19,7 15,8 20,8 28,9 0,93 0,84 0,78 0,99 0,91 0,72 1,00 0,92 0,80 1,00 0,96 0,81 1,25 1,45 1,96 1,61 2,10 5,79 2,30 3,73 6,09 2,84 4,56 9,52 1,25 1,45 1,96 1,60 2,09 5,78 2,26 3,67 6,03 2,78 4,49 9,47 1,1 1,4 1,7 1,5 1,9 3,7 1,9 2,9 4,3 2,6 3,7 6, ,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1, Mod. Mod. Mod. Mod G2 G4 G4 G4 R410 R410 R410 R410 2,5 2,8 3,1 3, /3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 7,2 18,0 10,0 28,4 4,2 5,2 5,7 8,2 5,04 5,53 4,91 5,74 5,24 3,47 4,96 4,66 4,02 5,56 4,74 3,77 5,04 5,53 4,91 5,78 5,26 3,48 5,04 4,74 4,06 5,68 4,81 3,79 49,7 51,0 51,0 58,4 58,4 58,4 61,1 63,3 63,3 61,1 62,9 64,9 49,7 51,0 51,0 58,2 58,2 58,2 60,6 63,0 63,0 60,8 62,6 64,7 44,8 45,1 45,1 47,3 47,3 47,3 49,5 51,1 51,1 49,5 50,8 52,3 34,3 35,0 35,0 40,3 40,3 40,3 43,0 45,2 45,2 43,0 44,8 46,8 44,8 45,1 45,1 49,9 49,9 49,9 52,3 54,5 54,5 52,4 54,2 56,1 44,8 45,1 45,1 40,5 40,5 40,5 42,9 45,1 45,1 43,0 44,8 46, " 1" 1" 1" 1" 1" 1" 1" 1" 1+1/4" 1+1/4" 1+1/4" 1/2'' 1/2'' 1/2'' 1/2'' 1/2'' 1/2'' 1/2'' 1/2'' 1/2'' 1/2'' 1/2'' 1/2'' MODEL COOLING CPCITY (1) Total Sensible SHR / Over Under Condenser water flow rate m 3 /h Condenser pressure drop kpa Supply fans n. ir flow m 3 /h Nominal external static pressure Over Pa Nominal external static pressure Under Pa Fans max external static pressure Pa Scroll compressors BLCD inverter type n. On/Off type n. Cooling capacity control ir filters n. Efficiency Refrigerant Refrigerant charge (2) Gas circuits n. Power supply Max operating current (FL) Unit starting current (LR) Energy efficiency indexes (1) EER Over (1) / EER Under (1) / Sound pressure level - ISO 3744 (3) On air delivery Over On air delivery Under On air intake Over Irradiated Over On air intake Under On front side Under Net weight Over Net weight Under Connections - ISO 228/1 G Condenser water inlet/outlet M Ø Condensate discharge - Rubber pipe F Ø 028 M1 034 M2 040 M2 053 M3 E4L E4L E5L E5L min nom max min nom max min nom max min nom max 17,2 29,1 38,6 17,4 39,4 54,4 20,6 45,5 58,1 27,1 58,8 77,8 17,2 29,1 37,7 17,4 38,7 47,1 20,6 43,7 54,8 27,1 57,5 68,2 1,00 1,00 0,98 1,00 0,98 0,87 1,00 0,96 0,94 1,00 0,98 0,88 2,84 6,93 11,70 2,77 9,34 16,14 3,15 8,94 16,55 4,85 12,84 19,35 2,68 6,69 11,32 2,61 8,97 15,77 3,07 8,82 16,37 4,77 12,67 19,16 2,8 5,0 6,9 2,8 6,8 9,9 3,4 7,7 10,4 4,6 10,0 13, ,00 1,00 1,00 1,00 1,00 1,00 2,00 2,00 2,00 2,00 2,00 2, Mod. Mod. Mod. Mod G4 G4 G4 G4 R410 R410 R410 R410 4,9 5,2 7,5 7, /3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 28,6 42,3 46,6 60,3 8,3 67,1 71,2 84,3 6,06 4,20 3,30 6,28 4,22 3,37 6,54 5,09 3,51 5,59 4,58 4,02 6,42 4,35 3,41 6,67 4,39 3,45 6,71 5,16 3,55 5,68 4,64 4,06 59,4 64,1 69,3 59,4 68,1 69,3 53,0 66,1 70,7 55,7 70,7 70,7 57,7 62,8 68,2 57,7 66,9 68,2 52,1 66,0 70,6 55,1 70,6 70,6 48,5 51,7 56,2 49,6 55,3 56,3 47,8 53,7 57,6 49,1 57,7 57,7 41,3 46,0 51,2 41,5 50,0 51,2 37,0 48,0 52,6 38,9 52,6 52,6 49,7 54,3 59,6 50,0 58,4 59,6 46,3 57,5 62,0 48,4 62,0 62,0 40,3 44,9 50,2 40,7 49,0 50,2 37,2 48,1 52,6 39,2 52,6 52, /2" 1+1/2" 1+1/2" 1+1/2" 1+1/2" 1+1/2" 2" 2" 2" 2" 2" 2" 1/2'' 1/2'' 1/2'' 1/2'' 1/2'' 1/2'' 1/2'' 1/2'' 1/2'' 1/2'' 1/2'' 1/2'' 50 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

51 IT Cooling TECHNICL DT MODEL COOLING CPCITY (1) Total Sensible SHR / Over Under Condenser water flow rate m 3 /h Condenser pressure drop kpa Supply fans n. ir flow m 3 /h Nominal external static pressure Over Pa Nominal external static pressure Under Pa Fans max external static pressure Pa Scroll compressors BLCD inverter type n. On/Off type n. Cooling capacity control ir filters n. Efficiency Refrigerant Refrigerant charge (2) Gas circuits n. Power supply (**) Max operating current (FL) Unit starting current (LR) Energy efficiency indexes (1) EER Over (1) / EER Under (1) / Sound pressure level - ISO 3744 (3) On air delivery Over On air delivery Under On air intake Over Irradiated Over On air intake Under On front side Under Net weight Over Net weight Under Connections - ISO 228/1 G Condenser water inlet/outlet M Ø Condensate discharge - Rubber pipe F Ø NEXT EVO INV DW 057 M3 040 D M2 065 D M2 080 D M4 E6L E5L E7L E8L min nom max min nom max min nom max min nom max 21,3 62,8 79,1 20,3 45,3 52,8 30,8 70,5 80,4 25,8 88,2 94,5 21,3 60,7 68,3 20,3 43,6 50,5 29,3 68,5 75,1 25,8 83,4 86,1 1,00 0,97 0,86 1,00 0,96 0,96 0,95 0,97 0,93 1,00 0,95 0,91 3,33 13,89 19,58 2,85 10,07 12,91 4,69 16,43 20,05 3,66 20,90 22,99 3,24 13,71 19,43 2,77 9,28 12,75 4,59 16,21 19,80 3,57 20,66 22,72 3,5 10,7 13,8 3,3 7,8 9,2 5,1 12,2 14,1 4,2 15,2 16, ,00 2,00 2,00 2,00 2,00 2,00 2,00 2,00 2,00 3,00 3,00 3, Mod. Mod. Mod. Mod G4 G4 G4 G4 R410 R410 R410 R410 8,2 8, /3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 60,3 42,8 61,3 73,2 84,3 14,4 16,6 147,3 6,40 4,52 4,04 7,12 4,50 4,09 6,57 4,29 4,01 7,05 4,22 4,11 6,57 4,58 4,07 7,33 4,88 4,14 6,71 4,35 4,06 7,23 4,27 4,16 50,8 67,8 67,8 53,0 66,1 69,3 49,8 67,2 68,3 51,2 73,3 73,3 50,3 67,9 67,9 52,1 66,0 69,2 47,8 67,0 68,2 49,7 73,2 73,2 48,5 55,3 55,3 47,4 53,6 56,3 48,4 54,7 55,7 47,1 60,1 60,1 36,7 49,7 49,7 36,7 48,0 51,2 36,4 49,1 50,2 35,9 55,2 55,2 46,1 59,3 59,3 46,8 57,5 60,6 45,4 58,5 59,6 44,9 64,6 64,6 37,0 49,9 49,9 37,7 48,1 51,2 36,4 49,1 50,2 35,9 55,1 55, " 2" 2" 2" 2" 2" 2"+1/2" 2"+1/2" 2"+1/2" 2"+1/2" 2"+1/2" 2"+1/2" 1/2'' 1/2'' 1/2'' 1/2'' 1/2'' 1/2'' 1/2'' 1/2'' 1/2'' 1/2'' 1/2'' 1/2'' MODEL COOLING CPCITY (1) Total Sensible SHR / Over Under Condenser water flow rate m 3 /h Condenser pressure drop kpa Supply fans n. ir flow m 3 /h Nominal external static pressure Over Pa Nominal external static pressure Under Pa Fans max external static pressure Pa Scroll compressors BLCD inverter type n. On/Off type n. Cooling capacity control ir filters n. Efficiency Refrigerant Refrigerant charge (2) Gas circuits n. Power supply Max operating current (FL) Unit starting current (LR) Energy efficiency indexes (1) EER Over (1) / EER Under (1) / Sound pressure level - ISO 3744 (3) On air delivery Over On air delivery Under On air intake Over Irradiated Over On air intake Under On front side Under Net weight Over Net weight Under Connections - ISO 228/1 G Condenser water inlet/outlet M Ø Condensate discharge - Rubber pipe F Ø 100 D M4 E9 min nom max 31,4 112,0 119,0 29,8 103,0 106,0 0,95 0,92 0,89 4,56 26,54 30,75 4,48 26,29 30,43 5,2 19,3 20, ,00 3,00 3, Mod. 6 G4 R410 15, /3/50+N 92,3 164,3 6,89 4,22 3,87 7,01 4,26 3,91 45,5 70,9 70,9 43,5 71,0 71,0 48,2 58,2 58,2 35,8 52,8 52,8 44,6 62,4 62,4 35,8 53,0 53, "+1/2" 2"+1/2" 2"+1/2" 1/2'' 1/2'' 1/2'' THE COOLING CPCITY DOES NOT CONSIDER THE SUPPLY FN MOTOR THERML LOD 1. Characteristics referred to entering air at 24 C-50%RH; water to the condenser C. 2. Unit refrigerant charge. Optional are excluded. 3. Noise level at 1 meter in free field (external static pressure at nominal conditions) fiftycoolyears RCGROUP Sp G_ITC_RCW8.4 51

52 NEXT EVO INV DW TECHNICL DT - OPTIONL CCESSORIES NEXT EVO INV DW Electric heater Capacity Capacity steps n. Humidifier Steam capacity /h Power input Extra circuit coil (1) Total cooling capacity Sensible cooling capacity Heating coil (2) Heating capacity Free-cooling coil (1) Total cooling capacity Sensible cooling capacity IT Cooling M1 M1 M1 M1 M1 M2 M2 M3 M3 D M2 D M2 D M4 D M4 E0 E1 E2 E3 E4L E4L E5L E5L E6L E5L E7L E8L E9L 2,5 5,1 5,1 6,0 9,0 9,0 13,5 13,5 13,5 13,5 13,5 18,0 18, ,4 2,3 2,3 2,3 6,0 6,0 6,0 6,0 6,0 6,0 11,3 11,3 11,3-11,0 18,1 24,7 39,0 44,7 55,4 68,7 69,5 63,3 94,2 117,0 135,0-10,0 16,5 22,4 35,4 40,7 49,7 62,3 63,3 52,5 80,0 98,3 115,0-24,1 36,2 50,5 81,4 92,5 109,0 126,0 148,0 109,0 160,0 193,0 232,0-11,0 18,1 24,7 39,0 44,7 55,4 68,7 69,5 63,3 94,2 117,0 135,0-10,0 16,5 22,4 35,4 40,7 49,7 62,3 63,3 52,5 80,0 98,3 115,0 THE COOLING/HETING CPCITY DOES NOT CONSIDER THE SUPPLY FN MOTOR THERML LOD ccessories technical data are referred to nominal conditions. 1. Characteristics referred to entering air at 24 C 50%RH with chiller water at 7/12,5 C and 0% glycol 2. Characteristics referred to entering air at 20 C with hot water at 75/60 C DIMENSIONS (mm) a b c E E E E E4L E5L E6L E7L E8L E9L c a b 52 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

53 NEXT EVO CW S NEXT EVO CW S: Close control air conditioners for chilled water feeding with upflow or downflow air delivery Cooling Capacity: CHILLEDWTER ECFN COOLNET NEXT EVO CW S rcgroupairconditioning E C CHILLED WTER UP FLOW DOWN FLOW MIN FETURES Chilled water feeding precision air conditioner. 15 models available, 2 versions for a wide selection opportunity. Chilled water feeding. Two-way chilled water valves. EC plug-fans. Variable air flow. Variable water flow. SHR ratio 0,94. Plug fans certified ERP Cooling density up to 68,9 /m 2. Upflow (OVER) or downflow (UNDER) air delivery. Suitable for indoor installation. MIN BENEFITS Technical synergy with RC Group liquid chillers. vailability of electric heater. vailability of steam humidifier. vailability of hot water heating coil. vailability of extra circuit heating coil. vailability of units with separate fan section, PLUS. Complete set of optional accessories: filters, plenum, panels, stand. Easily of maintenance. INDOOR INSTLLTION The machines are designed for indoor installation. WORKING LIMITS Room air temperature: 14 C minimum temperature with wet bulb. 24 C maximum temperature with wet bulb. 35 C maximum temperature with dry bulb. Room air humidity: 20%RH minimum relative humidity. 75%RH maximum relative humidity. Chilled water temperature: ΔT 7 C Maximum temperature difference between chilled water inlet and outlet fiftycoolyears RCGROUP Sp G_ITC_RCW8.4 53

54 NEXT EVO CW S MIN COMPONENTS FRMEWORK Base in aluminium extrusion, painted with epoxy powders. Colour RL 9005; Frame in aluminium profile, painted with epoxy powders. The inner frame is provided with seals for the panels. Colour RL 9005; Panels in galvanized steel sheet with protective surfaces treatment in compliance with UNI ISO 9227/STMB117 and ISO 7253, and painted with epoxy powders. Colour RL 7016 hammered; Panels insulated with polyurethane foam and seals to ensure air tight. Hinged front panels with quick release removal system. Total front access for routine maintenance. Removable lateral and back side panels. ir flow OVER version: - ir intake from the front through honeycomb type grille and air delivery from the top. - Washable air pre-filters with G2 efficiency, with cells in synthetic fibre (size F0 excluded). ir flow UNDER version: Machine size F0: - ir intake from the front through honeycomb type grille and air delivery from the bottom. Machine size F1, F2, F3, F3P, F4, F5, F6, F7, F8, F9 and all PLUS series: - ir intake from the top and air delivery from the bottom. Compartment for electrical panel on unit front for direct access to control and regulation devices; FILTER SECTION Size F0: - Washable air filters with G2 efficiency, with cells in synthetic fibre and metallic frame (EN ). Size F1, F2, F3, F3P, F4, F5, F6, F7, F8, F9 and all PLUS series: - Washable air filters with G4 efficiency, with cells in synthetic fibre and metallic frame (EN ). ir filters access: OVER version - Frontal access for all machines UNDER version - For machines size F0 - F1 F2 F3 frontal access. For machine size F3P - F4 F5 F6 F7 F8 F9 and all PLUS series access from upper side. COOLING SECTION Heat exchanger coil with internally corrugated copper tubes and high efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops. Finned pack with hydrophilic treatment that assure the condensate water drop, high thermal conductivity and does not favour the growth of microorganisms. 2-way motorized valve for water flow regulation with 0 10 VDC control actuator and emergency manual control. Frame in galvanized steel. Condensate tray in peralluman with PVC flexible discharge pipe. ir temperature sensors upstream and downstream the cooling section, with control, regulation and limitation functions. Temperature probes on chilled water inlet / outlet. IT Cooling NEXT EVO CW S & K PLUS The fan section is separated and is designed to be fixed under the machine. The fan section provides the air discharge from the front and can be installed in the raised floor void or directly on the floor for downflow air delivery. It is possible to provide the air flow towards the rear of the machine by moving the panels and the fan guard see chapter NEXT EVO CW PLUS installation diagram. The fans section includes: Height adjusting rubber holders. Centrifugal fans with backward curved blades with wing profile, single suction and without scroll housings (Plug-fans), directly coupled to external rotor electric motor. - Impeller in composite material exempt from rust formation. - Brushless type synchronous EC motor with integrated electronic commutated system and continuous variation of the rotation speed. The motor rotation control is obtained with the EC system (Electronic Commutation) that manage the motor according to the signal coming from the microprocessor control. Fans control through ModBus. Fan guard with rubber support on air intake and delivery ELECTRICL PNEL In accordance with EN norms, suitable for indoor installation, complete wit: Main switch with door lock safety on frontal panel;. Magnetothermic switches for supply fans. The supply fans equipped with EC electric motor and don t require contactors. Transformer for auxiliary circuit and microprocessor supply. Terminals: OUTLETS - Voltage free deviating contact for General larm 1 - Voltage free contact for supply fans status. INLETS - Emergency unit stop with signalling on display (external alarm). - External enabling. Power supply 400/3/50+N. CONTROL SYSTEM Microprocessor control system with graphic display for control and monitor of operating and alarms status. The system includes: Built-in clock for alarms date and time displaying and storing; Built-in memory for the storing of the intervened events (up to 100 events recorded); Predisposition for connectivity board housing ( RCcom MBUS/JBUS, LON, BCnet for Ethernet (SNMP- TCP/IP), BCnet for MS/TP). The electronic cards are optional accessories; Main components hour-meter; Non-volatile Flash memory for data storage in case of power supply faulty; nalogue set point compensation (0 1 Vdc) according to an external analogue signal at Customer care; Menu with protection password; LN connection (max 15 units). FNS SECTION NEXT EVO CW S & K OVER / UNDER The fan section is contained within the machine and includes: Centrifugal fans with backward curved blades with wing profile, single suction and without scroll housings (Plug-fans), directly coupled to external rotor electric motor. - Impeller in composite material exempt from rust formation. - Brushless type synchronous EC motor with integrated electronic commutated system and continuous variation of the rotation speed. The motor rotation control is obtained with the EC system (Electronic Commutation) that manage the motor according to the signal coming from the microprocessor control. Fans control through ModBus. Fan guard with rubber support (UNDER version) 54 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

55 IT Cooling COMMON OPTIONL CCESSORIES NEXT EVO CW S C fan - DOWNGRDE H2O deviation valve (3 way) Floor stand Hmax=350 mm Floor stand Hmax=450 mm Floor stand Hmax=510 mm Disposal F5 efficiency air filter ir supply plenum with F6 filters ir supply plenum with F7 filters ir supply plenum with F9 filters ir supply plenum with sound absorber ir return plenum with sound absorber ir discharge plenum with frontal and lateral grilles ir discharge plenum with frontal grille ir supply plenum with 5 closed sides Sandwich panels 945 -ir return plenum with Free Cooling damper Extra-Circuit system Steam humidifier Dehumification system Electric heater Increased electrical heater Water heater + 2 way valve Differential pressure air control utomatic S/W operation Clogged filters alarm Water presence alarm dditional water sensor (kit) T/rH sensor on air return T/rH external sensor T/rH remote sensor Contact enabling the smoke / fire RC-Com MBUS/JBUS Serial board LON Serial board BCnet Ethernet - SNMP - TCP/IP Serial board BCnet MS/TP Serial board Double serial interface Emergency microprocessor supply Dual power supply Remote terminal shared Remote graphic terminal kit Kit modem GSM Plantwatch without modem SOFTWRE DVNCED - COOLNET RC CLOUD PLTFORM NEXT EVO CW S F0 F1 F2 F3 F3P F4 F5 F6 F7 F8 F9 F7 F8 F9 F10 S S S S S S S S S S S PLUS PLUS PLUS PLUS OPTIONL CCESSORIES - OVER VERSION ONLY NEXT EVO CW S Condensate discharge system (kit) Blind frontal pannel Plenum with frontal grille and sound absorber coustic panel Motorized damper with frame Incresed umidifier F0 F1 F2 F3 F3P F4 F5 F6 F7 F8 F9 S S S S S S S S S S S OPTIONL CCESSORIES - UNDER VERSION ONLY NEXT EVO CW S Condensate discharge system (kit) Condensate discharge system Motorized damper with frame Incresed umidifier F0 F1 F2 F3 F3P F4 F5 F6 F7 F8 F9 F7 F8 F9 F10 S S S S S S S S S S S PLUS PLUS PLUS PLUS available accessory; - not available accessory fiftycoolyears RCGROUP Sp G_ITC_RCW8.4 55

56 NEXT EVO CW S IT Cooling TECHNICL DT - NEXT EVO CW S MODEL VERSION COOLING CPCITY (1) Total Sensible SHR / Power input Supply fans n. ir flow m 3 /h Nominal external static pressure Pa Max external static pressure Pa Cooling coil Water flow rate m 3 /h Pressure drop - coil + valve kpa ir filters n. Efficiency Power supply Max operating current (FL) Sound level - ISO 3744 (2) On air delivery Over On air delivery Under On air intake Over Irradiated Over On air intake Under On front side Under Net weight Over Net weight Under Connections Water inlet/outlet - ISO 7/1 - R M Ø Condensate discharge Rubber pipe F Ø F0 F1 F2 F3 F3P F4 F5 F6 F7 F8 F9 S S S S S S S S S S S 6,7 12,7 20,8 31,8 44,9 52,8 71,5 80,7 100,0 120,0 138,0 5,8 11,9 19,4 29,9 42,1 49,8 67,7 76,1 94,0 114,0 130,0 0,87 0,94 0,93 0,94 0,94 0,94 0,95 0,94 0,94 0,95 0,94 0,10 0,34 0,88 1,66 2,20 2,15 2,90 3,47 3,98 6,22 6, ,2 2,2 3,6 5,5 7,7 9,1 12,3 13,9 17,2 20,5 23, G2 G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 230/1/50 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 1,29 2,31 1,79 4,39 4,65 4,52 8,78 9,30 9,03 13,17 13,95 55,0 61,1 67,0 70,2 70,8 75,8 73,8 72,2 77,2 78,6 76,1 55,0 61,1 67,0 70,2 70,8 75,8 73,8 72,2 77,2 78,6 76,1 47,8 46,6 47,1 50,6 52,7 56,5 54,1 54,1 57,8 58,9 58,0 35,4 42,4 43,2 46,5 48,7 52,9 50,0 50,1 54,3 54,8 54,0 42,1 51,7 52,6 56,1 58,2 61,9 59,6 59,5 63,3 64,4 63,5 35,4 42,4 43,2 46,5 48,7 52,9 50,0 50,1 54,3 54,8 54, /4" 1" 1" 1+1/4" 1+1/4" 1+1/2" 2" 2" 2+1/2" 2+1/2" 3" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" TECHNICL DT - NEXT EVO CW S PLUS MODEL VERSION COOLING CPCITY (1) Total Sensible SHR / Power input Under Supply fans n. ir flow m 3 /h Nominal external static pressure Under Pa Max external static pressure Pa Cooling coil Water flow rate m 3 /h Pressure drop - coil + valve kpa ir filters n. Efficiency Power supply Max operating current (FL) Sound level - ISO 3744 (2) On air delivery Under On air intake Under On front side Under Net weight Under Net weight - Separate fan section Connections Water inlet/outlet - ISO 7/1 - R M Ø Condensate discharge Rubber pipe F Ø F7 F8 F9 F10 PLUS PLUS PLUS PLUS S S S S 125,0 148,0 173,0 225,0 118,0 139,0 162,0 212,0 0,94 0,94 0,94 0,94 6,57 6,34 7,00 8, ,5 25,3 29,6 38, G4 G4 G4 G4 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 13,17 13,95 13,55 18,06 79,8 76,8 81,5 81,7 65,6 64,2 67,6 67,8 56,0 54,8 58,6 58, /2" 3" 3" 3" 1/2" 1/2" 1/2" 1/2" THE COOLING CPCITY DOES NOT CONSIDER THE SUPPLY FN MOTOR THERML LOD 1. Characteristics referred to entering air at 24 C-50%RH with chilled water temperature 7-12 C - 0% glycol. 2. Noise level at 1 meter in free field. 56 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

57 IT Cooling TECHNICL DT - OPTIONL CCESSORIES NEXT EVO CW S Electric heater Capacity Capacity steps n. Oversized Electric heater Capacity Capacity steps n. Humidifier Steam capacity /h Power input Oversized Humidifier Steam capacity /h Power input Extra circuit coil (1) Total cooling capacity Sensible cooling capacity Heating coil (2) Heating capacity NEXT EVO CW S F0 F1 F2 F3 F3P F4 F5 F6 F7 F8 F9 F7 F8 F9 F PLUS PLUS PLUS PLUS 2,6 5,1 5,1 6,0 6,0 9,0 13,5 13,5 13,5 18,0 18,0 18,0 18,0 27,0 27, ,0 9,0 13,5 18,0 18,0 18,0 27,0 27, ,4 2,3 2,3 2,3 2,3 6,0 6,0 6,0 11,3 11,3 11,3 11,3 11,3 11,3 11, (*) 8 (*) 8 (*) ,0 (*) 6,0 (*) 6,0 (*) 6,0 11,3 11,3 11, ,6 18,1 28,6 39,4 49,8 65,5 74,3 95,1 101,0 121,0 103,0 129,0 169,0 216, ,8 17,0 27,0 37,0 47,4 62,2 70,6 90,0 95,5 114,0 97,4 122,0 160,0 203,0 12,2 26,7 35,4 57,0 78,7 101,0 126,0 155,0 181,0 190,0 236,0 198,0 242,0 327,0 405,0 THE COOLING CPCITY DOES NOT CONSIDER THE SUPPLY FN MOTOR THERML LOD 1. Characteristics referred to entering air at 24 C 50%RH with chiller water at 7-12,5 C and 0% glycol 2. Characteristics referred to entering air at 20 C with hot water at C (*) Only OVER version fiftycoolyears RCGROUP Sp G_ITC_RCW8.4 57

58 NEXT EVO CW S IT Cooling NEXT EVO CW S DIMENSIONS (mm) a b c F F F F F3P F F F F F F c a b NEXT EVO CW S PLUS DIMENSIONS (mm) a b c1 c2 E7 PLUS E8 PLUS E9 PLUS E10 PLUS c1 c2 a b 58 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

59 NEXT EVO CW K NEXT EVO CW K: Close control air conditioners for chilled water feeding with upflow or downflow air delivery Cooling Capacity: CHILLEDWTER ECFN COOLNET NEXT EVO CW K rcgroupairconditioning E C CHILLED WTER UP FLOW DOWN FLOW MIN FETURES Chilled water feeding precision air conditioner. 14 models available, 2 versions for a wide selection opportunity. Chilled water feeding. Two-way chilled water valves. EC plug-fans. Variable air flow. Variable water flow. SHR ratio 0,89. Plug fans certified ERP Cooling density up to 85,7/m 2. Upflow (OVER) or downflow (UNDER) air delivery. Suitable for indoor installation. MIN BENEFITS Technical synergy with RC Group liquid chillers. vailability of electric heater. vailability of steam humidifier. vailability of units with separate fan section, PLUS. Complete set of optional accessories: filters, plenum, panels, stand. Easily of maintenance. INDOOR INSTLLTION The machines are designed for indoor installation. WORKING LIMITS Room air temperature: 14 C minimum temperature with wet bulb. 24 C maximum temperature with wet bulb. 35 C maximum temperature with dry bulb. Room air humidity: 20%RH minimum relative humidity. 75%RH maximum relative humidity. Chilled water temperature: ΔT 7 C Maximum temperature difference between chilled water inlet and outlet fiftycoolyears RCGROUP Sp G_ITC_RCW8.4 59

60 NEXT EVO CW K MIN COMPONENTS FRMEWORK Base in aluminium extrusion, painted with epoxy powders. Colour RL 9005; Frame in aluminium profile, painted with epoxy powders. The inner frame is provided with seals for the panels. Colour RL 9005; Panels in galvanized steel sheet with protective surfaces treatment in compliance with UNI ISO 9227/STMB117 and ISO 7253, and painted with epoxy powders. Colour RL 7016 hammered; Panels insulated with polyurethane foam and seals to ensure air tight. Hinged front panels with quick release removal system. Total front access for routine maintenance. Removable lateral and back side panels. ir flow OVER version: - ir intake from the front through honeycomb type grille and air delivery from the top. - Washable air pre-filters with G2 efficiency, with cells in synthetic fibre (size F0 excluded). ir flow UNDER version: Machine size F0: - ir intake from the front through honeycomb type grille and air delivery from the bottom. Machine size F1, F2, F3, F3P, F4, F5, F6, F7, F8, F9 and all PLUS series: - ir intake from the top and air delivery from the bottom. Compartment for electrical panel on unit front for direct access to control and regulation devices; FILTER SECTION Size F0: - Washable air filters with G2 efficiency, with cells in synthetic fibre and metallic frame (EN ). Size F1, F2, F3, F3P, F4, F5, F6, F7, F8, F9 and all PLUS series: - Washable air filters with G4 efficiency, with cells in synthetic fibre and metallic frame (EN ). ir filters access: OVER version - Frontal access for all machines UNDER version - For machines size F0 - F1 F2 F3 frontal access. For machine size F3P - F4 F5 F6 F7 F8 F9 and all PLUS series access from upper side. COOLING SECTION Heat exchanger coil with internally corrugated copper tubes and high efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops. Finned pack with hydrophilic treatment that assure the condensate water drop, high thermal conductivity and does not favour the growth of microorganisms. 2-way motorized valve for water flow regulation with 0 10 VDC control actuator and emergency manual control. Frame in galvanized steel. Condensate tray in peralluman with PVC flexible discharge pipe. ir temperature sensors upstream and downstream the cooling section, with control, regulation and limitation functions. Temperature probes on chilled water inlet / outlet. IT Cooling NEXT EVO CW S & K PLUS The fan section is separated and is designed to be fixed under the machine. The fan section provides the air discharge from the front and can be installed in the raised floor void or directly on the floor for downflow air delivery. It is possible to provide the air flow towards the rear of the machine by moving the panels and the fan guard see chapter NEXT EVO CW PLUS installation diagram. The fans section includes: Height adjusting rubber holders. Centrifugal fans with backward curved blades with wing profile, single suction and without scroll housings (Plug-fans), directly coupled to external rotor electric motor. - Impeller in composite material exempt from rust formation. - Brushless type synchronous EC motor with integrated electronic commutated system and continuous variation of the rotation speed. The motor rotation control is obtained with the EC system (Electronic Commutation) that manage the motor according to the signal coming from the microprocessor control. Fans control through ModBus. Fan guard with rubber support on air intake and delivery ELECTRICL PNEL In accordance with EN norms, suitable for indoor installation, complete wit: Main switch with door lock safety on frontal panel;. Magnetothermic switches for supply fans. The supply fans equipped with EC electric motor and don t require contactors. Transformer for auxiliary circuit and microprocessor supply. Terminals: OUTLETS - Voltage free deviating contact for General larm 1 - Voltage free contact for supply fans status. INLETS - Emergency unit stop with signalling on display (external alarm). - External enabling. Power supply 400/3/50+N. CONTROL SYSTEM Microprocessor control system with graphic display for control and monitor of operating and alarms status. The system includes: Built-in clock for alarms date and time displaying and storing; Built-in memory for the storing of the intervened events (up to 100 events recorded); Predisposition for connectivity board housing ( RCcom MBUS/JBUS, LON, BCnet for Ethernet (SNMP- TCP/IP), BCnet for MS/TP). The electronic cards are optional accessories; Main components hour-meter; Non-volatile Flash memory for data storage in case of power supply faulty; nalogue set point compensation (0 1 Vdc) according to an external analogue signal at Customer care; Menu with protection password; LN connection (max 15 units). FNS SECTION NEXT EVO CW S & K OVER / UNDER The fan section is contained within the machine and includes: Centrifugal fans with backward curved blades with wing profile, single suction and without scroll housings (Plug-fans), directly coupled to external rotor electric motor. - Impeller in composite material exempt from rust formation. - Brushless type synchronous EC motor with integrated electronic commutated system and continuous variation of the rotation speed. The motor rotation control is obtained with the EC system (Electronic Commutation) that manage the motor according to the signal coming from the microprocessor control. Fans control through ModBus. Fan guard with rubber support (UNDER version) 60 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

61 IT Cooling COMMON OPTIONL CCESSORIES NEXT EVO CW K C fan - DOWNGRDE H2O deviation valve (3 way) Floor stand Hmax=350 mm Floor stand Hmax=450 mm Floor stand Hmax=510 mm Disposal F5 efficiency air filter ir supply plenum with F6 filters ir supply plenum with F7 filters ir supply plenum with F9 filters ir supply plenum with sound absorber ir return plenum with sound absorber ir discharge plenum with frontal and lateral grilles ir discharge plenum with frontal grille ir supply plenum with 5 closed sides Sandwich panels 945 -ir return plenum with Free Cooling damper Steam humidifier Electric heater Increased electrical heater Differential pressure air control utomatic S/W operation Clogged filters alarm Water presence alarm dditional water sensor (kit) T/rH sensor on air return T/rH external sensor T/rH remote sensor Contact enabling the smoke / fire RC-Com MBUS/JBUS Serial board LON Serial board BCnet Ethernet - SNMP - TCP/IP Serial board BCnet MS/TP Serial board Double serial interface Emergency microprocessor supply Dual power supply Remote terminal shared Remote graphic terminal kit Kit modem GSM Plantwatch without modem SOFTWRE DVNCED - COOLNET RC CLOUD PLTFORM NEXT EVO CW K F1 F2 F3 F3P F4 F5 F6 F7 F8 F9 F7 F8 F9 F10 K K K K K K K K K K PLUS PLUS PLUS PLUS OPTIONL CCESSORIES - OVER VERSION ONLY NEXT EVO CW K Condensate discharge system (kit) Blind frontal pannel Plenum with frontal grille and sound absorber coustic panel Motorized damper with frame Incresed umidifier F1 F2 F3 F3P F4 F5 F6 F7 F8 F9 K K K K K K K K K K OPTIONL CCESSORIES - UNDER VERSION ONLY NEXT EVO CW K Condensate discharge system (kit) Condensate discharge system (kit) Motorized damper with frame Incresed umidifier F1 F2 F3 F3P F4 F5 F6 F7 F8 F9 F7 F8 F9 F10 K K K K K K K K K K PLUS PLUS PLUS PLUS available accessory; - not available accessory fiftycoolyears RCGROUP Sp G_ITC_RCW8.4 61

62 NEXT EVO CW K IT Cooling TECHNICL DT - NEXT EVO CW K MODEL VERSION COOLING CPCITY (1) Total Sensible SHR / Power input Supply fans n. ir flow m 3 /h Nominal external static pressure Pa Max external static pressure Pa Cooling coil Water flow rate m 3 /h Pressure drop - coil + valve kpa ir filters n. Efficiency Power supply Max operating current (FL) Sound level - ISO 3744 (2) On air delivery Over On air delivery Under On air intake Over Irradiated Over On air intake Under On front side Under Net weight Over Net weight Under Connections Water inlet/outlet - ISO 7/1 - R M Ø Condensate discharge Rubber pipe F Ø F1 F2 F3 F3P F4 F5 F6 F7 F8 F9 K K K K K K K K K K 15,5 24,7 38,7 58,4 65,6 88,1 109,0 125,0 150,0 172,0 12,9 21,4 34,0 50,1 58,1 75,7 93,4 109,0 130,0 150,0 0,83 0,87 0,88 0,86 0,89 0,86 0,86 0,87 0,87 0,87 0,32 0,91 1,78 2,51 2,58 3,36 4,06 4,85 7,22 7, ,7 4,2 6,6 10,0 11,3 15,1 18,8 21,4 25,7 29, G2 G4 G4 G4 G4 G4 G4 G4 G4 G4 230/1/50 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 2,31 1,79 4,39 4,65 4,52 8,78 9,30 9,03 13,17 13,95 60,3 66,9 70,2 70,8 75,9 74,0 72,1 77,5 78,8 76,0 60,3 66,9 70,2 70,8 75,9 74,0 72,1 77,5 78,8 76,0 45,7 47,0 50,5 52,7 56,6 54,3 54,1 58,1 59,1 57,9 41,6 43,1 46,5 48,7 53,0 50,2 50,1 54,6 55,0 53,9 50,8 52,6 56,0 58,2 62,0 59,8 59,5 63,6 64,6 63,4 41,6 43,1 46,5 48,7 53,0 50,2 50,1 54,6 55,0 53, " 1+1/4" 1+1/2" 1+1/2" 2" 2" 2+1/2" 2+1/2" 3" 3" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" TECHNICL DT - NEXT EVO CW K PLUS MODEL VERSION COOLING CPCITY (1) Total Sensible SHR / Power input Under Supply fans n. ir flow m 3 /h Nominal external static pressure Under Pa Max external static pressure Pa Cooling coil Water flow rate m 3 /h Pressure drop - coil + valve kpa ir filters n. Efficiency Power supply Max operating current (FL) Sound level - ISO 3744 (2) On air delivery Under On air intake Under On front side Under Net weight Under Net weight - Separate fan section Connections Water inlet/outlet - ISO 7/1 - R M Ø Water inlet/outlet - DN - PN10 (3) Condensate discharge Rubber pipe F Ø F7 F8 F9 F10 PLUS PLUS PLUS PLUS K K K K 152,0 180,0 211,0 279,0 132,0 154,0 183,0 240,0 0,87 0,86 0,87 0,86 6,92 6,90 7,73 10, ,1 30,9 36,2 47, G4 G4 G4 G4 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 13,17 13,95 13,55 18,06 79,1 76,0 81,1 81,7 65,0 63,4 67,2 67,8 55,4 53,9 58,1 58, " 3" /2" 1/2" 1/2" 1/2" THE COOLING CPCITY DOES NOT CONSIDER THE SUPPLY FN MOTOR THERML LOD 1. Characteristics referred to entering air at 24 C-50%RH with chilled water temperature 7-12 C - 0% glycol. 2. Noise level at 1 meter in free field. 3. The counter-flange is not supplied. It is at Customer charge 62 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

63 IT Cooling NEXT EVO CW K TECHNICL DT - OPTIONL CCESSORIES NEXT EVO CW K Electric heater Capacity Capacity steps n. Oversized Electric heater Capacity Capacity steps n. Humidifier Steam capacity /h Power input Oversized Humidifier F1 F2 F3 F3P F4 F5 F6 F7 F8 F9 F7 F8 F9 F PLUS PLUS PLUS PLUS 5,1 5,1 6,0 6,0 9,0 13,5 13,5 13,5 18,0 18,0 18,0 18,0 27,0 27, ,3 2,3 2,3 2,3 6,0 6,0 6,0 11,3 11,3 11,3 11,3 11,3 11,3 11, ,0 18,1 26,4 36,8 46,5 64,2 69,5 84,7 101,0 109,0 129,0 150,0 193, ,0 16,5 24,0 33,4 42,5 59,0 63,3 76,9 92,6 98,8 118,0 136,0 176,0 Steam capacity /h 12,6 24,1 36,2 53,8 75,3 95,1 126,0 148,0 166,0 193,0 212,0 247,0 297,0 - Power input 6,0 (*) 6,0 (*) 6,0 (*) 6,0 11,3 11,3 11, THE COOLING CPCITY DOES NOT CONSIDER THE SUPPLY FN MOTOR THERML LOD (*) Only OVER version fiftycoolyears RCGROUP Sp G_ITC_RCW8.4 63

64 NEXT EVO CW K IT Cooling NEXT EVO CW K DIMENSIONS (mm) a b c F F F F3P F F F F F F c a b NEXT EVO CW K PLUS DIMENSIONS (mm) a b c1 c2 E7 PLUS E8 PLUS E9 PLUS E10 PLUS c1 c2 a b 64 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

65 NEXT EVO DX NEXT EVO DX: Direct expansion close control air conditioners with up-flow or down-flow air delivery. Cooling Capacity: NEW SOFTWRE NEXT EVO DXR410 rcgroupairconditioning E C C UP FLOW DOWN FLOW MIN FETURES Precision air conditioner. 20 models available, 2 versions for a wide selection opportunity. EER up to 4,47. On/off scroll compressors. Single and double refrigerant circuit. R410 Refrigerant charge. rotary compressor (size E1, E2). C plug-fans (size E3, E4, E5, E6, E7, E8). OVER and UNDER versions. Suitable for indoor installation. MIN BENEFITS Units with single and double refrigerant circuits. vailability of remote condensers with axial fans (TEM MTE series) and with plug fans (TEM MTE PF series). High EER. vailability of EC plug-fans. vailability of electronic expansion valves. vailability of electric heater. vailability of steam humidifier. vailability of hot water heating coil. vailability of extra circuit heating coil. Complete set of optional accessories: filters, plenum, panels, stand. Easily of maintenance. INDOOR INSTLLTION The machines are designed for indoor installation. REMOTE CONDENSER The units are designed to be matched with remote condensers with axial fans (TEM MTE series) or plug-fans (TEM MTE PF series). WORKING LIMITS Room air temperature: 14 C minimum temperature with wet bulb. 24 C maximum temperature with wet bulb. 35 C maximum temperature with dry bulb. Room air humidity: 20%RH minimum relative humidity. 70%RH maximum relative humidity fiftycoolyears RCGROUP Sp G_ITC_RCW8.4 65

66 NEXT EVO DX MIN COMPONENTS FRMEWORK Base in aluminium extrusion, painted with epoxy powders. Colour RL 9005; Frame in aluminium profile, painted with epoxy powders. The inner frame is provided with seals for the panels. Colour RL 9005; Panels in galvanized steel sheet with protective surfaces treatment in compliance with UNI ISO 9227/STMB117 and ISO 7253, and painted with epoxy powders. Colour RL 7016 hammered; Panels insulated with polyurethane foam and seals to ensure air tight. Hinged front panels with quick release removal system. Total front access for routine maintenance. Removable lateral and back side panels. ir flow OVER version: - ir intake from the front through honeycomb type grille and air delivery from the top. ir flow UNDER version: - ir intake from the top and air delivery from the bottom. Compartment for electrical panel on unit front for direct access to control and regulation devices; FILTER SECTION Washable air filters with G4 efficiency, with cells in synthetic fibre and metallic frame (EN ). ir filters access: OVER version - Frontal access for all machines UNDER version - For machines size E1 E2 E3 frontal access - For machine size E4 E5 E67 E7 E8 access from upper side IT Cooling ELECTRICL PNEL In accordance with EN norms, suitable for indoor installation, complete wit: Main switch with door lock safety on frontal panel;. Magnetothermic switches for supply fans. The supply fans equipped with EC electric motor and don t require contactors. Transformer for auxiliary circuit and microprocessor supply. Terminals: OUTLETS - Voltage free deviating contact for General larm 1 - Voltage free contact for supply fans status. INLETS - Emergency unit stop with signalling on display (external alarm). - External enabling. Power supply 400/3/50+N. CONTROL SYSTEM Microprocessor control system with graphic display for control and monitor of operating and alarms status. The system includes: Built-in clock for alarms date and time displaying and storing; Built-in memory for the storing of the intervened events (up to 100 events recorded); Predisposition for connectivity board housing ( RCcom MBUS/JBUS, LON, BCnet for Ethernet (SNMP- TCP/IP), BCnet for MS/TP). The electronic cards are optional accessories; Main components hour-meter; Non-volatile Flash memory for data storage in case of power supply faulty; Menu with protection password; LN connection (max 15 units). ON / OFF COMPRESSORS SECTION Units size E1 and E2: Rotary vane compressors for R410 refrigerant 2-pole 3-phase electric motor with direct on line starting. Crankcase heater. Rubber supports. Units size E3, E4, E5, E6, E7 and E8 Scroll rotary compressors with spiral profile optimized for R410 refrigerant. 2-pole 3-phase electric motor with direct on line starting. Crankcase heater. Rubber supports. COOLING SECTION Heat exchanger coil with internally corrugated copper tubes and high efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops. Frame in galvanized steel or peralluman. Condensate tray in peralluman with PVC flexible discharge pipe. Temperature sensors on air intake with control and regulation functions. Temperature sensors on air delivery with function of temperature display. REFRIGERNT CIRCUIT Components for each refrigerant circuit: Mechanical expansion valve. Sight glass. Filter dryer on liquid line. Pressure transducers with indication, control and protection functions, on low and high refrigerant pressure. High pressure safety switch with manual reset. Liquid receiver with accessories. Refrigerant circuit with copper tubing with anticondensate insulation of the suction line. Plastic capillary hoses for pressure sensors connection. R410 refrigerant charge and lubricant oil. Valves on gas delivery and liquid return for coupling to remote air cooled condenser. 0 10V proportional signal to manage the condensing control system of the remote air cooled condenser. TO BE MTCHED WITH REMOTE CONDENSER The units are designed to be matched with remote condensers with axial fans (TEM MTE series) or plug-fans (TEM MTE PF series). FNS SECTION The fan section is contained within the machine and includes: Centrifugal fans with backward curved blades with wing profile, single suction and without scroll housings (Plug-fans), directly coupled to external rotor electric motor. Impeller in composite material exempt from rust formation. C type electric motor with fixed speed. Fan guard with rubber support (UNDER version) TEM MTE TEM MTE PF 66 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

67 IT Cooling COMMON OPTIONL CCESSORIES TEM MTE remote condenser TEM MTE PF remote condenser Team Mate electrical power supply by internal unit Floor stand Hmax=350 mm Floor stand Hmax=450 mm Floor stand Hmax=510 mm Disposal F5 efficiency air filter ir supply plenum with F6 filters ir supply plenum with F7 filters ir supply plenum with F9 filters ir supply plenum with sound absorber ir discharge plenum with frontal and lateral grilles ir discharge plenum with frontal grille ir supply plenum with 5 closed sides Sandwich panels 945 -ir return plenum with Free Cooling damper Extra-Circuit system Water heater + 2 way valve Steam humidifier Incresed umidifier Phases sequence relay Electric heater Increased electrical heater Clogged filters alarm Water presence alarm dditional water sensor (kit) T/rH sensor on air return T/rH external sensor T/rH remote sensor Noise deading cup on compressor Compr. power factor capacitor - 0, Liquid solenoid valve Electronic expansion valve EC fan RC-Com MBUS/JBUS Serial board LON Serial board BCnet Ethernet - SNMP - TCP/IP Serial board BCnet MS/TP Serial board Double serial interface Emergency microprocessor supply Remote terminal shared Remote graphic terminal kit Kit modem GSM Plantwatch without modem RC CLOUD PLTFORM NEXT EVO DX E2 E3 E4 E5 E6 E7 E OPTIONL CCESSORIES - OVER VERSION ONLY Condensate discharge system (kit) Blind frontal pannel Plenum with frontal grille and sound absorber Bottom panel H0 H1 H2 H3 H4 H5 H5 OPTIONL CCESSORIES - UNDER VERSION ONLY ir return plenum with sound absorber Condensate discharge system (kit) Condensate discharge system Motorized damper with frame H0 H1 H2 H3 H4 H5 H available accessory; - not available accessory fiftycoolyears RCGROUP Sp G_ITC_RCW8.4 67

68 NEXT EVO DX TECHNICL DT MODEL IT Cooling 007 P1 009 P1 011 P1 014 P1 016 P1 020 P1 022 P1 026 P1 032 P1 037 P1 041 P1 COOLING CPCITY (1) Total Sensible SHR / Supply fans n. ir flow m 3 /h Nominal external static pressure Pa Fans max external static pressure Pa Compressors Quantity n. Capacity steps n. ir filters n. Efficiency Refrigerant Refrigerant charge (2) Gas circuits n. Power supply (**) Max operating current (FL) Unit starting current (LR) Energy efficiency indexes (1) EER / Sound pressure level - ISO 3744 (3) On air delivery Under/Over On air intake Over Irradiated Over On air intake Under On front side Under Net weight Over Net weight Under Remote condenser (4) n. TEM MTE Mod. TEM MTE PF Mod. Refrigerant connections Gas delivery ODS Ø Liquid return ODS Ø Hydraulic connections - Condensate discharge F Ø MODEL COOLING CPCITY (1) Total Sensible SHR / Supply fans n. ir flow m 3 /h Nominal external static pressure Pa Fans max external static pressure Pa Compressors Quantity n. Capacity steps n. ir filters n. Efficiency Refrigerant Refrigerant charge (2) Gas circuits n. Power supply (**) Max operating current (FL) Unit starting current (LR) Energy efficiency indexes (1) EER / Sound pressure level - ISO 3744 (3) On air delivery Under/Over On air intake Over Irradiated Over On air intake Under On front side Under Net weight Over Net weight Under Remote condenser (4) n. TEM MTE Mod. TEM MTE PF Mod. Refrigerant connections 68 E1 E1 E1 E2 E2 E3 E3 E3 E4 E4 E4 7,3 8,8 10,2 13,5 14,5 19,7 21,7 25,8 31,9 36,0 40,7 7,0 8,4 9,7 12,8 13,8 18,8 20,6 24,3 30,4 33,0 38,8 0,95 0,95 0,95 0,95 0,95 0,95 0,95 0,94 0,95 0,92 0,95 1,73 2,16 2,62 3,39 3,78 4,41 5,34 6,55 7,42 8,35 9, rotary rotary rotary rotary rotary scroll scroll scroll scroll scroll scroll G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 R410 R410 R410 R410 R410 R410 R410 R410 R410 R410 R410 3,2 3,2 3,2 3,4 3,4 4,0 4,0 4,0 5,7 5,7 8, /3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 6,1 7,0 7,2 8,5 9,1 15,4 18,8 20,1 22,2 25,7 30,4 33,3 40,3 37,5 54,5 54,5 66,9 77,9 103,9 130,9 141,9 122,0 4,22 4,07 3,89 3,98 3,84 4,47 4,06 3,94 4,30 4,31 4,16 58,0 59,6 60,4 62,6 63,6 63,5 65,0 66,0 72,0 75,1 71,2 49,8 50,2 51,9 51,3 53,0 53,9 57,7 55,1 57,8 58,9 58,8 40,2 41,4 42,4 40,4 41,7 42,4 45,5 44,0 48,6 51,3 49,4 50,1 52,3 52,3 50,5 52,0 52,5 55,2 54,3 58,9 61,4 59,7 40,9 42,1 43,2 41,3 42,9 43,4 46,3 45,1 49,6 52,0 50, M 11 M 11 M 11 M 14 M 17 M 25 M 25 M 30 M 35 M 45 M 45 T 11 T 11 T 11 T 14 T 21 T 24 T 24 T 33 T 38 T 44 T /2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 045 P1 039 P2 048 P2 055 P2 062 P2 075 P2 082 P2 092 P2 102 P2 D D D D D D D D E4 E5 E5 E6 E6 E7 E7 E8 E8 44,3 36,5 47,1 54,5 61,3 74,6 81,3 89,9 102,0 40,5 34,1 42,9 51,9 58,4 71,1 76,2 81,4 89,6 0,91 0,93 0,91 0,95 0,95 0,95 0,94 0,91 0,88 10,78 8,59 11,69 13,20 14,77 17,68 19,59 21,56 25, scroll scroll scroll scroll scroll scroll scroll scroll scroll G4 G4 G4 G4 G4 G4 G4 G4 G4 R410 R410 R410 R410 R410 R410 R410 R410 R410 8,6 9,0 9,0 9,8 9,8 16,2 16,2 17,4 17, /3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 36,7 27,8 35,7 40,1 44,3 53,7 60,9 73,5 79,8 144,0 78,7 94,0 123,0 152,0 168,6 151,0 179,0 216,0 4,11 4,25 4,03 4,13 4,15 4,22 4,15 4,17 4,02 71,2 75,2 74,1 71,8 72,6 72,3 72,3 74,7 74,7 57,6 59,0 59,2 58,5 60,3 60,6 61,3 62,6 63,4 48,0 51,5 50,5 48,7 49,9 50,7 51,0 53,0 53,3 59,9 61,6 60,8 59,0 60,1 61,0 61,3 63,3 63,6 50,8 52,1 51,4 49,7 50,9 51,8 52,2 54,1 54, M 50 M 25 M 25 M 30 M 35 M 45 M 45 M 50 M 60 T 58 T 24 T 33 T 33 T 38 T 38 T 58 T 58 T69 Gas delivery ODS Ø 28 2x18 2x18 2x18 2x18 2x22 2x28 2x28 2x28 Liquid return ODS Ø 22 2x12 2x16 2x16 2x16 2x16 2x22 2x22 2x22 Hydraulic connections - Condensate discharge F Ø 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" THE COOLING CPCITY DOES NOT CONSIDER THE SUPPLY FN MOTOR THERML LOD 1. Characteristics referred to entering air at 24 C-45%RH; 45 C condensing temperature. 2. Unit refrigerant charge. Remote condenser, connections pipes and optional are excluded. 3. Noise level at 1 meter in free field (external static pressure 50 Pa) 4. For matching to other remote air cooled condensers please refer to RC WORLD selection program (**) The remote condenser has separated power supply G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

69 IT Cooling NEXT EVO DX TECHNICL DT - OPTIONL CCESSORIES NEXT EVO DX Electric heater Capacity Capacity steps n. Humidifier Steam capacity /h Power input Extra circuit coil (1) Total cooling capacity Sensible cooling capacity Heating coil (2) Heating capacity NEXT EVO DX Electric heater Capacity Capacity steps n. Humidifier Steam capacity /h Power input Extra circuit coil (1) Total cooling capacity Sensible cooling capacity Heating coil (2) Heating capacity 007 P1 009 P1 011 P1 014 P1 016 P1 020 P1 022 P1 026 P1 032 P1 037 P1 E1 E1 E1 E2 E2 E3 E3 E3 E4 E4 5,1 5,1 5,1 5,1 5,1 6,0 6,0 6,0 9,0 9,0 1,0 1,0 1,0 1,0 1,0 2,0 2,0 2,0 3,0 3, ,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 6,0 6,0 10,4 11,0 11,3 16,7 17,4 23,7 25,0 25,8 35,8 35,8 9,6 10,0 10,3 15,3 15,7 21,8 22,7 23,5 32,7 32,7 22,9 24,1 24,7 33,6 34,7 48,8 51,1 52,7 75,1 75,1 041 P1 045 P1 039 P2 D 048 P2 D 055 P2 D 062 P2 D 075 P2 D 082 P2 D 092 P2 D 102 P2 D E4 E4 E5 E5 E6 E6 E7 E7 E8 E8 9,0 9,0 13,5 13,5 13,5 13,5 18,0 18,0 18,0 18,0 3,0 3,0 3,0 3,0 3,0 3,0 3,0 3,0 3,0 3, ,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 41,5 41,5 42,4 50,0 61,1 61,1 94,2 94,2 105,0 105,0 37,7 37,7 36,8 44,2 55,4 55,4 80,0 80,0 87,1 87,1 86,2 86,2 85,0 98,8 131,0 134,0 160,0 160,0 175,0 175,0 1. Characteristics referred to entering air at 24 C 50%RH with chiller water at 7/12,5 C and 0% glycol 2. Characteristics referred to entering air at 20 C with hot water at 75/60 C fiftycoolyears RCGROUP Sp G_ITC_RCW8.4 69

70 NEXT EVO DX IT Cooling NEXT EVO DX DIMENSIONS (mm) DIMENSIONS (mm) a b c E E E E E E E E c a b 70 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

71 NEXT DW NEXT DW: Direct expansion close control air conditioners with built-in water cooled condenser equipped with scroll compressors and Plug-fans. Cooling Capacity: NEXT DW rcgroupairconditioning R410 E C C UP FLOW DOWN FLOW MIN FETURES Precision air conditioner. 41 models available, 2 versions for a wide selection opportunity. EER up to 4,89. On/off scroll compressors. Single and double refrigerant circuit. Built in water cooled condenser. R410 Refrigerant charge. EC plug-fans (size H0, H1, H2, H3). C plug-fans (size H4, H5, H6, H7). OVER and UNDER versions. Suitable for indoor installation. MIN BENEFITS Units with single and double refrigerant circuits. High EER. High efficiency at partial load. vailability of electric heater. vailability of steam humidifier. vailability of hot water heating coil. vailability of extra circuit heating coil. vailability of indirect Free Cooling system. Complete set of optional accessories: filters, plenum, panels, stand. Easily of maintenance. INDOOR INSTLLTION The machines are designed for indoor installation. WORKING LIMITS Room air temperature: 14 C minimum temperature with wet bulb. 24 C maximum temperature with wet bulb. 35 C maximum temperature with dry bulb. Room air humidity: 20%RH minimum relative humidity. 75%RH maximum relative humidity. Water cooled condenser: Water temperature: 30/50 C Outlet temperature range fiftycoolyears fiftycoolyears RCGROUP Sp G_ITC_RCW8.4 71

72 NEXT DW MIN COMPONENTS FRMEWORK Base in aluminium extrusion, painted with epoxy powders. Inner frame and upper frame in aluminium profile, painted with epoxy powders. The inner frame is provided with seals to ensure air tight with the panels. Galvanized steel sheet panels externally coated with PVC film and internally insulated with noise absorption material. The panels are fixed to the frame with non visible mounting system. Electric board in separate technical compartment on the machine front (Size H0, H1, H2, H3). Separate technical compartment on machine front for electric board, refrigerant and hydraulic connections and control and regulation devices (size H4, H5, H6, H7) Colour: RL 9005 for base and frame Similar to RL7015 for panels, with hammered finish OVER version - ir intake from the front through honeycomb type grille and air delivery from the top. - Washable air pre-filters with G2 efficiency, with cells in synthetic fibre (size H0 excluded). UNDER version Machine size H0 - ir intake from the front through honeycomb type grille and air delivery from the bottom. Machine size H1, H2, H3, H4, H5, H6, H7 - ir intake from the top and air delivery from the bottom. COMPRESSORS Orbiting spiral (SCROLL) hermetic compressors with spiral profile optimized for R410 refrigerant. ON / OFF capacity control (0 / 100% each compressor). 2-pole 3-phase electric motor with direct on line starting. Crankcase heater. Electric motor thermal protection via internal winding temperature sensors. Terminal box with IP54 enclosure class. Rubber supports. IT Cooling REFRIGERNT CIRCUIT Components for each refrigerant circuit: Thermostatic expansion valve. Sight glass. Filter dryer on liquid line. Pressure transducers with indication, control and protection functions, on low and high refrigerant pressure. High pressure safety switch with manual reset. Liquid receiver with accessories. Refrigerant circuit with copper tubing with anticondensate insulation of the suction line. Plastic capillary hoses for pressure sensors connection. R410 refrigerant charge. ELECTRICL PNEL In accordance with EN norms complete with: Main switch with door lock safety. Magnetothermic switch for each compressor. Magnetothermic switches for fans. Contactors for each load. The supply fans equipped with EC electric motor are not supplied with contactors. Transformer for auxiliary circuit and microprocessor supply. Panel with machine controls. Power supply: - 230/1/50 for model 006 P1 S H /3/50 for the other models. CONTROL SYSTEM MP.COM microprocessor system with graphic display for control and monitor of operating and alarms status. The system includes: - Voltage free contact for remote general alarm. - Main components hour-meter. - Nonvolatile Flash memory for data storage. - Menu with protection password. - LN connection. FILTER SECTION Size H0 Washable air filters with G3 efficiency, with cells in synthetic fibre and metallic frame (EN ). Size H1, H2, H3, H4, H5, H6, H7 Washable air filters with G4 efficiency, with cells in synthetic fibre and metallic frame (EN ). EVPORTING SECTION Heat exchanger coil with internally corrugated copper tubes and high efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops. - With single refrigerant circuit for S version machines. - With double refrigerant circuit for DC version machines. Frame in galvanized steel. Condensate tray in peraluman with PVC flexible discharge pipe. CONDENSING SECTION Copper brazed plate type with cover plates, plates and connections in ISI 316 stainless steel. 0 10V proportional signal to manage the condensing control system of the 2-way motorized valve. The valve is an optional accessory. FNS SECTION Centrifugal fans with backward curved blades, single suction and without scroll housings (Plug-fans), directly coupled to external rotor electric motor. - Size H0, H1, H2, H3: Brushless type synchronous EC motor with integrated electronic commutated system and continuous variation of the rotation speed. The motor rotation control is obtained with the EC system (Electronic Commutation) that manage the motor according to the 0 10V proportional signal coming from the microprocessor control. - Size H4, H5, H6, H7: Fans fed through an autotransformer that allows the manual selection of 7 rotation speed. Temperature sensors on air intake. Fan guard with rubber support (UNDER version) 72 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

73 IT Cooling COMMON OPTIONL CCESSORIES VERSION DRY COOLER DRY COOLER PF FC Free Cooling system Pumping group single pump Pumping group double pump Water regulating valve Floor stand Hmax=350 mm Floor stand Hmax=450 mm Floor stand Hmax=510 mm Disposal F5 efficiency air filter ir supply plenum with F6 filters ir supply plenum with F7 filters ir supply plenum with F9 filters ir supply plenum with sound absorber 945 -ir return plenum with Free Cooling damper Motorized damper with frame EC fan 912 -ir flow loss alarm EC Fan Electronic expansion valve Liquid solenoid valve ON-OFF Hot gas reh.system Extra-Circuit system Steam humidifier Dehumification system Electric heater Hot water heating coil + 3 way valve Clogged filters alarm ir flow loss alarm dditional water sensor (kit) Water presence alarm Noise deading cup on compressor Compr. power factor capacitor - 0, Capacity control Phase control relay Clock card Driver card RC-Com MBUS/JBUS Serial board LON Serial board BCnet Ethernet - SNMP - TCP/IP Serial board BCnet MS/TP Serial board MP.COM expansion card Serial card for GSM Modem Data Logger Temperature/Humidity sensor Outlet air temperature indication Current indication Voltage indication Remote terminal shared Remote graphic terminal kit Kit modem GSM Plantwatch without modem RC CLOUD PLTFORM NEXT DW H0 H1 H2 H3 H4 H5 H5 H6 H6 H7 H7 H7 H7 S S S S S S D S D S D S D OPTIONL CCESSORIES - OVER VERSION ONLY VERSION Condensate discharge system (kit) Blind frontal pannel ir discharge plenum with grilles Plenum with frontal grille and sound absorber Sandwich panels Bottom panel H0 H1 H2 H3 H4 H5 H5 H5 H5 H6 H6 H7 H7 S S S S S S S S DC S DC S DC available accessory; - not available accessory OPTIONL CCESSORIES - UNDER VERSION ONLY VERSION Condensate discharge system (kit) Condensate discharge system H0 H1 H2 H3 H4 H5 H5 H5 H5 H6 H6 H7 H7 S S S S S S S S DC S DC S DC available accessory; - not available accessory fiftycoolyears RCGROUP Sp G_ITC_RCW8.4 73

74 NEXT DW IT Cooling TECHNICL DT MODEL COOLING CPCITY (1) Total Sensible SHR / Condenser water flow rate m 3 /h Condenser pressure drop kpa Supply fans n. ir flow m 3 /h Nominal external static pressure Pa Fans max external static pressure Pa Compressors Quantity n. Capacity steps n. ir filters n. Efficiency Refrigerant Refrigerant charge (2) Gas circuits n. Power supply Max operating current (FL) Unit starting current (LR) Energy efficiency indexes (1) EER / Sound pressure level - ISO 3744 (3) On air delivery Under/Over On air intake Over Irradiated Over On air intake Under On front side Under Net weight Over Net weight Under Connections - ISO 228/1 G Condenser water inlet/outlet M Ø Condensate discharge - Rubber pipe F Ø 006.P1 008.P1 010.P1 007.P1 009.P1 011.P1 013.P1 014.P1 015.P1 017.P1 019.P1 S S S S S S S S S S S H0 H0 H0 H1 H1 H1 H1 H2 H2 H2 H3 6,9 8,2 9,9 7,6 9,0 10,6 12,0 13,1 15,8 18,4 18,4 5,8 6,7 7,7 7,2 8,6 9,4 10,0 12,5 14,0 15,3 17,4 0,84 0,82 0,78 0,95 0,95 0,89 0,83 0,95 0,89 0,83 0,95 1,5 1,8 2,2 1,6 1,9 2,3 2,6 2,7 3,3 3,8 4,3 1,2 1,4 1,7 1,3 1,5 1,8 2,1 2,2 2,7 3,1 3, G3 G3 G3 G4 G4 G4 G4 G4 G4 G4 G4 R410 R410 R410 R410 R410 R410 R410 R410 R410 R410 R410 2,6 2,6 2,6 4,8 4,8 4,8 4,8 5,9 5,9 5,9 7, /1/50 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 14,8 7,7 8,7 7,2 8,6 9,7 10,7 10,4 12,8 14,4 16,9 61,3 39,3 47,3 30,2 40,2 48,2 45,2 44,9 53,9 65,9 68,3 4,49 4,60 4,49 4,89 4,65 4,57 4,56 4,85 4,77 4,83 4,30 55,7 58,3 60,4 56,7 59,7 59,7 59,7 64,7 64,7 64,7 65,2 50,7 52,5 54,6 49,7 50,6 51,9 51,9 53,9 53,9 55,5 55,7 39,5 41,5 43,6 39,7 41,9 42,4 42,4 46,6 46,6 46,8 47,2 50,7 52,5 54,6 49,7 51,9 51,9 52,4 56,5 56,5 56,9 57,3 50,7 52,5 54,6 40,4 42,6 42,6 43,1 47,1 47,1 47,6 48, " 1" 1" 1" 1" 1" 1" 1+1/2" 1+1/2" 1+1/2" 1+1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" MODEL COOLING CPCITY (1) Total Sensible SHR / Condenser water flow rate m 3 /h Condenser pressure drop kpa Supply fans n. ir flow m 3 /h Nominal external static pressure Pa Fans max external static pressure Pa Compressors Quantity n. Capacity steps n. ir filters n. Efficiency Refrigerant Refrigerant charge (2) Gas circuits n. Power supply Max operating current (FL) Unit starting current (LR) Energy efficiency indexes (1) EER / Sound pressure level - ISO 3744 (3) On air delivery Under/Over On air intake Over Irradiated Over On air intake Under On front side Under Net weight Over Net weight Under Connections - ISO 228/1 G Condenser water inlet/outlet M Ø Condensate discharge - Rubber pipe F Ø 021.P1 023.P1 025.P1 029.P1 033.P1 038.P1 040.P1 045.P1 049.P1 026.P2 028.P2 S S S S S S S S S DC DC H3 H3 H4 H4 H4 H5 H5 H5 H5 H5 H5 20,1 22,4 27,2 30,7 35,9 37,7 41,4 45,1 52,5 25,7 32,7 18,7 19,6 24,9 26,7 29,4 35,5 37,0 38,4 40,5 23,8 31,1 0,93 0,88 0,92 0,87 0,82 0,94 0,89 0,85 0,77 0,93 0,95 5,2 5,9 6,2 6,8 7,7 8,5 9,4 10,5 12,2 5,7 7,9 3,6 4,0 4,6 5,2 6,1 6,4 7,0 7,7 9,0 4,4 5, G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 R410 R410 R410 R410 R410 R410 R410 R410 R410 R410 R410 7,5 7,5 9,3 9,3 9,3 15,3 15,4 15,5 15,9 9,9 10, /3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 20,3 20,3 19,5 24,7 25,7 27,5 30,7 37,0 40,1 19,5 26,0 79,3 105,3 97,6 113,5 120,5 122,2 122,2 144,2 178,2 53,6 66,2 3,90 3,82 4,37 4,49 4,67 4,41 4,39 4,31 4,31 4,52 4,14 65,2 65,2 69,2 72,2 72,2 74,9 74,9 74,9 74,9 69,1 74,9 58,4 56,3 58,1 60,7 60,7 62,6 62,9 63,2 63,5 57,7 62,6 48,2 47,4 51,1 54,1 54,1 56,8 56,8 56,8 56,8 51,0 56,8 58,2 57,5 61,0 62,6 62,6 66,4 66,5 66,5 67,2 61,1 66,5 49,0 48,2 51,6 53,3 53,3 57,0 57,1 57,2 57,8 51,8 57, /2" 1+1/2" 1+1/2" 1+1/2" 1+1/2" 2" 2" 2" 2" 1+1/2" 1+1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" THE COOLING CPCITY DOES NOT CONSIDER THE SUPPLY FN MOTOR THERML LOD 1. Characteristics referred to entering air at 24 C-50%RH; water to the condenser C 2. Unit refrigerant charge optional excluded. 3. Noise level at 1 meter in free field (external static pressure 50 Pa) 4. Characteristics referred to entering air at 24 C 50%RH with chiller water at 7/12,5 C and 0% glycol 5. Characteristics referred to entering air at 20 C with hot water at 75/60 C 74 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

75 IT Cooling NEXT DW TECHNICL DT MODEL COOLING CPCITY (1) Total Sensible SHR / Condenser water flow rate m 3 /h Condenser pressure drop kpa Supply fans n. ir flow m 3 /h Nominal external static pressure Pa Fans max external static pressure Pa Compressors Quantity n. Capacity steps n. ir filters n. Efficiency Refrigerant Refrigerant charge (2) Gas circuits n. Power supply Max operating current (FL) Unit starting current (LR) Energy efficiency indexes (1) EER / Sound pressure level - ISO 3744 (3) On air delivery Under/Over On air intake Over Irradiated Over On air intake Under On front side Under Net weight Over Net weight Under Connections - ISO 228/1 G Condenser water inlet/outlet M Ø Condensate discharge - Rubber pipe F Ø MODEL COOLING CPCITY (1) Total Sensible SHR / Condenser water flow rate m 3 /h Condenser pressure drop kpa Supply fans n. ir flow m 3 /h Nominal external static pressure Pa Fans max external static pressure Pa Compressors Quantity n. Capacity steps n. ir filters n. Efficiency Refrigerant Refrigerant charge (2) Gas circuits n. Power supply Max operating current (FL) Unit starting current (LR) Energy efficiency indexes (1) EER / Sound pressure level - ISO 3744 (3) On air delivery Under/Over On air intake Over Irradiated Over On air intake Under On front side Under Net weight Over Net weight Under Connections - ISO 228/1 G Condenser water inlet/outlet M Ø Condensate discharge - Rubber pipe F Ø 032.P2 036.P2 042.P2 048.P2 048.P2 052.P2 052.P2 060.P2 060.P2 064.P2 064.P2 DC DC DC S DC S DC S DC S DC H5 H5 H6 H6 H6 H6 H6 H6 H6 H6 H6 35,7 41,7 44,7 50,0 50,2 54,7 55,0 62,6 62,7 64,4 65,2 33,5 37,1 40,9 42,9 43,0 48,8 48,9 53,8 53,8 58,9 58,9 0,94 0,89 0,91 0,86 0,86 0,89 0,89 0,86 0,86 0,91 0,90 8,9 10,2 10,0 11,2 11,1 12,7 12,6 13,9 13,9 13,9 13,9 6,1 7,2 7,6 8,6 8,6 9,4 9,4 10,7 10,7 11,0 11, G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 R410 R410 R410 R410 R410 R410 R410 R410 R410 R410 R410 10,7 10,9 19,9 19,7 19,9 20,2 20,4 20,8 20,9 21,4 21, /3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 29,2 35,9 37,0 37,0 37,0 39,1 39,1 49,6 49,6 49,6 49,6 80,2 94,2 95,2 121,2 121,2 116,2 116,2 137,2 137,2 137,2 137,2 4,01 4,07 4,48 4,47 4,52 4,31 4,37 4,50 4,50 4,63 4,68 74,9 74,9 67,3 67,3 67,3 70,8 70,8 72,5 72,5 75,4 75,4 62,6 64,0 61,3 59,0 59,0 60,3 60,3 62,2 62,2 63,8 63,8 56,8 57,0 52,4 50,7 50,7 53,0 53,0 54,8 54,8 57,3 57,3 66,6 67,1 62,0 60,6 60,6 63,1 63,1 66,6 66,6 67,3 67,3 57,2 57,8 53,0 51,5 51,5 53,9 53,9 57,3 57,3 58,0 58, /2" 1+1/2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 072.P2 072.P2 082.P2 082.P2 092.P2 092.P2 100.P2 100.P2 S DC S DC S DC S DC H7 H7 H7 H7 H7 H7 H7 H7 76,6 76,8 86,9 87,3 95,9 96,1 108,0 108,0 67,3 67,3 77,7 77,8 83,4 83,5 84,6 84,7 0,88 0,88 0,89 0,89 0,87 0,87 0,78 0,78 16,6 16,5 19,1 18,9 21,0 21,0 24,7 24,5 13,0 13,0 14,7 14,7 16,3 16,3 18,5 18, G4 G4 G4 G4 G4 G4 G4 G4 R410 R410 R410 R410 R410 R410 R410 R410 27,7 27, ,7 28,6 28,7 28,8 28, /3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 55,0 55,0 61,3 61,3 73,9 73,9 80,2 80,2 148,4 148,4 151,4 151,4 179,4 179,4 216,4 216,4 4,62 4,66 4,55 4,62 4,56 4,57 4,38 4,40 73,1 73,1 77,9 77,9 79,7 79,7 79,7 79,7 62,5 62,5 65,9 65,9 67,5 67,5 67,7 67,7 55,3 55,3 59,8 59,8 61,6 61,6 61,6 61,6 65,4 65,4 69,7 69,7 71,4 71,4 71,5 71,5 56,1 56,1 60,3 60,3 62,0 62,0 62,1 62, " 2" 2" 2" 2" 2" 2" 2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" THE COOLING CPCITY DOES NOT CONSIDER THE SUPPLY FN MOTOR THERML LOD 1. Characteristics referred to entering air at 24 C-50%RH; water to the condenser C 2. Unit refrigerant charge optional excluded. 3. Noise level at 1 meter in free field (external static pressure 50 Pa) 4. Characteristics referred to entering air at 24 C 50%RH with chiller water at 7/12,5 C and 0% glycol 5. Characteristics referred to entering air at 20 C with hot water at 75/60 C fiftycoolyears RCGROUP Sp G_ITC_RCW8.4 75

76 NEXT DW IT Cooling TECHNICL DT - OPTIONL CCESSORIES NEXT DW Hot gas reheating system Heating capacity Electric heater Capacity Capacity steps n. Humidifier Steam capacity /h Power input Extra circuit coil (1) Total cooling capacity Sensible cooling capacity Heating coil (2) Heating capacity NEXT DW Hot gas reheating system Heating capacity Electric heater Capacity Capacity steps n. Humidifier Steam capacity /h Power input Extra circuit coil (1) Total cooling capacity Sensible cooling capacity Heating coil (2) Heating capacity 006.P1 008.P1 010.P1 007.P1 009.P1 011.P1 013.P1 014.P1 015.P1 017.P1 019.P1 021.P1 023.P1 025.P1 029.P1 S S S S S S S S S S S S S S S H0 H0 H0 H1 H1 H1 H1 H2 H2 H2 H3 H3 H3 H4 H ON-OFF ON-OFF ON-OFF ON-OFF ON-OFF ON-OFF ON-OFF ON-OFF ON-OFF ON-OFF ON-OFF ON-OFF ,4 6,6 8,3 9,9 9,6 12,6 14, ,5 19,7 20,8 24,3 2,6 2,6 2,6 5,1 5,1 5,1 5,1 5,1 5,1 5,1 5,1 5,1 5, ,4 1,4 1,4 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2, ,4 10,6 10,6 10,6 15,0 15,0 15,0 22,8 22,8 22,8 29,2 30, ,3 9,2 9,2 9,2 13,1 13,1 13,1 20,1 20,1 20,1 25,5 26,2 10,3 11,1 11,9 16,6 18,3 18,3 18,3 25,1 25,1 26,9 39,1 39,1 39,1 49,5 50,7 033.P1 038.P1 040.P1 045.P1 049.P1 026.P2 028.P2 032.P2 036.P2 042.P2 048.P2 048.P2 052.P2 052.P2 060.P2 S S S S S DC DC DC DC DC S DC S DC S H4 H5 H5 H5 H5 H5 H5 H5 H5 H6 H6 H6 H6 H6 H6 ON-OFF ON-OFF ON-OFF ON-OFF ON-OFF ON-OFF ON-OFF ON-OFF ON-OFF ON-OFF ON-OFF ON-OFF ON-OFF ON-OFF ON-OFF 28, ,1 42,1 14,5 14,5 16,5 16,5 16,3 16,3 16,3 20,7 20,7 24,3 9 13,5 13,5 13,5 13,5 13,5 13,5 13,5 13,5 13,5 13,5 13,5 13,5 13,5 13, ,3 11,3 11,3 11,3 11,3 11,3 30,0 40,4 40,4 40,4 40,4 30,5 40,4 40,4 40,4 48,9 49,2 49,2 55,7 55,7 58,7 26,2 35,3 35,3 35,3 35,3 26,8 35,3 35,3 35,3 42,8 43,0 43,0 48,6 48,6 51,3 50,7 72,3 72,3 72,3 72,3 56,2 72,1 72,3 72,3 91,0 91,0 91,4 102,0 102,0 107,0 NEXT DW Hot gas reheating system Heating capacity Electric heater Capacity Capacity steps n. Humidifier Steam capacity /h Power input Extra circuit coil (1) Total cooling capacity Sensible cooling capacity Heating coil (2) Heating capacity 060.P2 064.P2 064.P2 072.P2 072.P2 082.P2 082.P2 092.P2 092.P2 100.P2 100.P2 DC S DC S DC S DC S DC S DC H6 H6 H6 H7 H7 H7 H7 H7 H7 H7 H7 ON-OFF ON-OFF ON-OFF ON-OFF ON-OFF ON-OFF ON-OFF ON-OFF ON-OFF ON-OFF ON-OFF 24,3 23,8 23,8 27,7 27,7 31,3 31,3 35,5 35,5 42,2 42,2 13,5 13,5 13,5 13,5 13,5 13,5 13,5 13,5 13,5 13,5 13, ,3 11,3 11,3 11,3 11,3 11,3 11,3 11,3 11,3 11,3 11,3 58,7 62,9 62,9 80,4 80,4 90,9 90,9 94,4 94,4 94,4 94,4 51,3 55,0 55,0 69,0 69,0 79,3 79,3 82,8 82,8 82,8 82,8 107,0 114,0 114,0 131,0 131,0 146,0 146,0 152,0 152,0 152,0 152,0 1. Characteristics referred to entering air at 24 C 50%RH with chiller water at 7/12,5 C and 0% glycol 2. Characteristics referred to entering air at 20 C with hot water at 75/60 C NEXT DW DIMENSIONS (mm) a b c H H H H H H H H c a b 76 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

77 NEXT DL NEXT DL: Close control air conditioners with displacement air delivery with remote condenser, or built in water cooled condenser or for chilled water feeding Cooling capacity: 7,7 51,4 NEXT DL rcgroupairconditioning R410 CHILLED WTER E C DISPL CEMENT MIN FETURES Precision air conditioner. Displacement air delivery (DL). 35 models available, 3 versions for a wide selection opportunity. vailable in three versions: for matching with remote air cooled condenser (DX), with built-in water cooled condenser (DW), for chilled water feeding (CW). EC plug fans. Suitable for indoor installation DX Version: EER up to 3,74. On/off scroll compressors Single refrigerant circuit. R410 refrigerant charge. DW Version: EER up to 5,25. On/off scroll compressors Single refrigerant circuit. R410 refrigerant charge. Built in water cooled condenser CW Version: Chilled water feeding Two way chilled water valve Easily of maintenance. INDOOR INSTLLTION The machines are designed for indoor installation. WORKING LIMITS Room air temperature: 14 C minimum temperature with wet bulb. 24 C maximum temperature with wet bulb. 35 C maximum temperature with dry bulb. Room air humidity: 20%RH minimum relative humidity. 75%RH maximum relative humidity. Water cooled condenser: Water temperature: 30/50 C Outlet temperature range. MIN BENEFITS Wide selection opportunity. High EER High efficiency at partial load. vailability of electric heater. vailability of steam humidifier. Complete set of optional accessories: filters, plenum, panels, stand fiftycoolyears RCGROUP Sp G_ITC_RCW8.4 77

78 NEXT DL NEXT DX DL / NEXT DW DL MIN COMPONENTS FRMEWORK Base in aluminium extrusion, painted with epoxy powders. Inner frame and upper frame in aluminium profile, painted with epoxy powders. The inner frame is provided with seals to ensure air tight with the panels. Galvanized steel sheet panels externally coated with PVC film and internally insulated with noise absorption material. The panels are fixed to the frame with non visible mounting system. Electric board in separate technical compartment on the machine front. Colour: RL 9005 for base and frame Similar to RL7015 for panels, with hammered finish ir intake from the top and air delivery from the front (displacement). CONTROL SYSTEM MP.COM microprocessor system with graphic display for control and monitor of operating and alarms status. The system includes: - Voltage free contact for remote general alarm. - Main components hour-meter. - Nonvolatile Flash memory for data storage. - Menu with protection password. - LN connection. IT Cooling TO BE MTCHED WITH REMOTE CONDENSER The NEXT DX DL are designed to be matched with remote condensers with axial fans (TEM MTE series) or plug-fans (TEM MTE PF series). COMPRESSORS Orbiting spiral (SCROLL) hermetic compressors with spiral profile optimized for R410 refrigerant. ON / OFF capacity control (0 / 100% each compressor). 2-pole 3-phase electric motor with direct on line starting. Crankcase heater. Electric motor thermal protection via internal winding temperature sensors. Terminal box with IP54 enclosure class. Rubber supports. FILTER SECTION Washable air filters with G4 efficiency, with cells in synthetic fibre and metallic frame (EN ). TEM MTE TEM MTE PF EVPORTING SECTION Heat exchanger coil with internally corrugated copper tubes and high efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops. Single refrigerant circuit. Frame in galvanized steel. Condensate tray in peraluman with PVC flexible discharge pipe. FNS SECTION Centrifugal fans with backward curved blades, single suction and without scroll housings (Plug-fans), directly coupled to external rotor electric motor. Brushless type synchronous EC motor with integrated electronic commutated system and continuous variation of the rotation speed. The motor rotation control is obtained with the EC system (Electronic Commutation) that manage the motor according to the 0 10V proportional signal coming from the microprocessor control. Temperature sensors on air intake. Temperature sensor on air delivery. REFRIGERNT CIRCUIT Thermostatic expansion valve. Sight glass. Filter dryer on liquid line. Pressure transducers with indication, control and protection functions, on low and high refrigerant pressure. High pressure safety switch with manual reset. Liquid receiver with accessories. Refrigerant circuit with copper tubing with anticondensate insulation of the suction line. Plastic capillary hoses for pressure sensors connection. R410 refrigerant charge. NEXT DX DL: - Valves on gas delivery and liquid return for coupling to remote air cooled condenser V proportional signal to manage the condensing control system of the remote air cooled condenser. NEXT DW DL: - Copper brazed plate type with cover plates, plates and connections in ISI 316 stainless steel V proportional signal to manage the condensing control system of the 2-way motorized valve. ELECTRICL PNEL In accordance with EN norms complete with: Main switch with door lock safety. Magnetothermic switch for each compressor. Magnetothermic switches for fans. Contactors for each load. The supply fans equipped with EC electric motor are not supplied with contactors. Transformer for auxiliary circuit and microprocessor supply. Panel with machine controls. Power supply 400/3/50+N 78 NEXT CW DL MIN COMPONENTS FRMEWORK Base in aluminium extrusion, painted with epoxy powders. Inner frame and upper frame in aluminium profile, painted with epoxy powders. The inner frame is provided with seals to ensure air tight with the panels. Galvanized steel sheet panels externally coated with PVC film and internally insulated with noise absorption material. The panels are fixed to the frame with non visible mounting system. Electric board in separate technical compartment on the machine front. Colour: RL 9005 for base and frame Similar to RL7015 for panels, with hammered finish ir intake from the top and air delivery from the front (displacement). FILTER SECTION Washable air filters with G4 efficiency, with cells in synthetic fibre and metallic frame (EN ). COOLING SECTION Heat exchanger coil with internally corrugated copper tubes and high efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops. 3-way motorized valve for water flow regulation and emergency manual control. Frame in galvanized steel. Condensate tray in peraluman with PVC flexible discharge pipe. FNS SECTION Centrifugal fans with backward curved blades, single suction and without scroll housings (Plug-fans), directly coupled to external rotor electric motor. Brushless type synchronous EC motor with integrated electronic commutated system and continuous variation of the rotation speed. The motor rotation control is obtained with the EC system (Electronic Commutation) that manage the motor according to the 0 10V proportional signal coming from the microprocessor control. Temperature sensors on air intake. Temperature sensor on air delivery. ELECTRICL PNEL In accordance with EN norms complete with: Main switch with door lock safety. Magnetothermic switches for fans. Contactors for each load. The supply fans equipped with EC electric motor are not supplied with contactors. Transformer for auxiliary circuit and microprocessor supply. Panel with machine controls. Power supply 400/3/50+N CONTROL SYSTEM MP.COM microprocessor system with graphic display for control and monitor of operating and alarms status. The system includes: - Voltage free contact for remote general alarm. - Main components hour-meter. - Nonvolatile Flash memory for data storage. - Menu with protection password. - LN connection. G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

79 IT Cooling NEXT DL COMMON OPTIONL CCESSORIES - NEXT DX DL - NEXT DW DL MODEL Electronic expansion valve Liquid solenoid valve Steam humidifier Electric heater Compr. power factor capacitor - 0, Phase control relay Noise deading cup on compressor Disposal F5 efficiency air filter Floor stand Hmax=350 mm Floor stand Hmax=450 mm Floor stand Hmax=510 mm Condensate discharge system Sandwich panels Clogged filters alarm ir flow loss alarm EC Fan Water presence alarm dditional water sensor (kit) Temperature/Humidity sensor ir return plenum with Free Cooling damper Fresh air kit Clock card RC-Com MBUS/JBUS Serial board LON Serial board BCnet Ethernet - SNMP - TCP/IP Serial board BCnet MS/TP Serial board Serial card for GSM Modem Data Logger Kit modem GSM Plantwatch without modem Remote graphic terminal kit Remote terminal shared RC CLOUD PLTFORM 008 P1 009 P1 011 P1 012 P1 016 P1 018 P1 020 P1 021 P1 023 P1 026 P1 029 P1 034 P1 037 P1 043 P1 046 P1 S S S S S S S S S S S S S S S H1 H1 H1 H1 H2 H2 H2 H3 H3 H3 H3 H3S H3S H3L H3L OPTIONL CCESSORIES - NEXT DX DL NEXT DX DL TEM MTE remote condenser TEM MTE PF remote condenser Team Mate electrical power supply by internal unit OPTIONL CCESSORIES - NEXT DW DL NEXT DW DL Water regulating valve 008 P1 009 P1 011 P1 012 P1 016 P1 018 P1 020 P1 021 P1 023 P1 026 P1 029 P1 034 P1 037 P1 043 P1 046 P1 S S S S S S S S S S S S S S S H1 H1 H1 H1 H2 H2 H2 H3 H3 H3 H3 H3S H3S H3L H3L 008 P1 009 P1 011 P1 012 P1 016 P1 018 P1 020 P1 021 P1 023 P1 026 P1 029 P1 034 P1 037 P1 043 P1 046 P1 S S S S S S S S S S S S S S S H1 H1 H1 H1 H2 H2 H2 H3 H3 H3 H3 H3S H3S H3L H3L OPTIONL CCESSORIES - NEXT CW DL NEXT CW DL Steam humidifier Electric heater Disposal F5 efficiency air filter Floor stand Hmax=350 mm Floor stand Hmax=450 mm Floor stand Hmax=510 mm Condensate discharge system Sandwich panels Clogged filters alarm 912 -ir flow loss alarm EC Fan Water presence alarm dditional water sensor (kit) IN/OUT chilled water temp. Indication Temperature/Humidity sensor 945 -ir return plenum with Free Cooling damper Fresh air kit Clock card RC-Com MBUS/JBUS Serial board LON Serial board BCnet Ethernet - SNMP - TCP/IP Serial board BCnet MS/TP Serial board Serial card for GSM Modem Data Logger Kit modem GSM Plantwatch without modem Remote graphic terminal kit Remote terminal shared RC CLOUD PLTFORM H1 H2 H3 H3S H3L available accessory; - not available accessory fiftycoolyears RCGROUP Sp G_ITC_RCW8.4 79

80 NEXT DL IT Cooling TECHNICL DT - NEXT DX DL MODEL COOLING CPCITY (1) Total Sensible SHR P1 009 P1 011 P1 012 P1 016 P1 018 P1 020 P1 021 P1 023 P1 026 P1 S S S S S S S S S S H1 H1 H1 H1 H2 H2 H2 H3 H3 H3 7,7 9,0 10,5 11,5 15,4 17,0 19,2 21,2 23,2 25,2 7,4 8,6 10,0 10,6 14,7 15,6 17,0 20,2 21,9 22,9 0,95 0,96 0,95 0,92 0,95 0,92 0,89 0,95 0,94 0,91 2,1 2,6 3,0 3,5 4,5 5,0 6,0 5,8 6,7 7, scroll scroll scroll scroll scroll scroll scroll scroll scroll scroll G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 R410 R410 R410 R410 R410 R410 R410 R410 R410 R410 2,6 2,6 2,7 2,7 2,9 3,0 3,2 3,5 3,5 4, /3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 8,1 9,4 10,4 11,4 13,7 16,3 19,5 21,8 21,8 22,8 31,4 41,4 49,4 46,4 54,9 68,5 79,5 81,8 107,8 101,8 3,74 3,50 3,50 3,28 3,46 3,41 3,19 3,64 3,48 3,45 49,0 52,0 52,0 52,0 54,0 54,0 54,0 55,0 55,0 55,0 54,0 58,0 58,0 58,0 60,0 60,0 60,0 60,0 60,0 60, M 11 M 11 M 14 M 14 M 20 M 25 M 25 M 30 M 30 M /2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 029 P1 034 P1 037 P1 043 P1 046 P1 S S S S S H3 H3S H3S H3L H3L 28,3 34,4 37,0 40,8 43,8 24,3 30,9 32,0 39,0 40,5 0,86 0,90 0,86 0,96 0,92 8,0 9,4 10,8 11,0 12, scroll scroll scroll scroll scroll G4 G4 G4 G4 G4 R410 R410 R410 R410 R410 4,1 4,4 4,4 7,2 7, /3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 27,8 28,8 31,8 38,5 44,5 117,8 124,8 124,8 131,5 153,5 3,52 3,65 3,43 3,71 3,55 55,0 56,0 56,0 56,0 56,0 60,0 62,0 62,0 62,0 62, M 35 M 45 M 45 M 50 M 50 Gas delivery ODS Ø Liquid return ODS Ø Hydraulic connections - Condensate discharge F Ø 1/2" 1/2" 1/2" 1/2" 1/2" THE COOLING CPCITY DOES NOT CONSIDER THE SUPPLY FN MOTOR THERML LOD 1. Characteristics referred to entering air at 28 C-40%RH; 35 C ambient temperature. 2. Unit refrigerant charge. Remote condenser, connections pipes and optional are excluded. 3. Noise level at 1 meter in free field (external static pressure 50 Pa) 4. For matching to other remote air cooled condensers please refer to RC WORLD selection program (*) The value includes the remote condenser as shown in the table. (**) The remote condenser has separated power supply NEXT DX DL / (*) Supply fans n. ir flow m 3 /h Compressors Quantity n. Capacity steps n. ir filters n. Efficiency Refrigerant Refrigerant charge (2) Gas circuits n. Power supply (**) Max operating current (FL) (*) Unit starting current (LR) Energy efficiency indexes (1) EER (*) / Sound pressure level - ISO 3744 (3) On air intake On front side Net weight Remote condenser (4) n. TEM MTE Mod. Refrigerant connections Gas delivery ODS Ø Liquid return ODS Ø Hydraulic connections - Condensate discharge F Ø MODEL COOLING CPCITY (1) Total Sensible SHR / (*) Supply fans n. ir flow m 3 /h Compressors Quantity n. Capacity steps n. ir filters n. Efficiency Refrigerant Refrigerant charge (2) Gas circuits n. Power supply (**) Max operating current (FL) (*) Unit starting current (LR) Energy efficiency indexes (1) EER (*) / Sound pressure level - ISO 3744 (3) On air intake On front side Net weight Remote condenser (4) n. TEM MTE Mod. Refrigerant connections TECHNICL DT - OPTIONL CCESSORIES - NEXT DX DL Electric heater Capacity Capacity steps n. Humidifier Steam capacity /h Power input 008 P1 009 P1 011 P1 012 P1 016 P1 018 P1 020 P1 021 P1 023 P1 026 P1 029 P1 034 P1 037 P1 043 P1 046 P1 S S S S S S S S S S S S S S S H1 H1 H1 H1 H2 H2 H2 H3 H3 H3 H3 H3S H3S H3L H3L 5,1 5,1 5,1 5,1 5,1 5,1 5,1 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6, ,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

81 IT Cooling NEXT DL TECHNICL DT - NEXT DW DL MODEL COOLING CPCITY (1) Total Sensible SHR / Condenser water flow rate Condenser pressure drop kpa Supply fans n. ir flow m3/h Compressors Quantity n. Capacity steps n. ir filters n. Efficiency Refrigerant Refrigerant charge (2) Gas circuits n. Power supply Max operating current (FL) Unit starting current (LR) Energy efficiency indexes (1) EER / Sound pressure level - ISO 3744 (3) On air intake On front side Net weight Hydraulic connections Condenser water inlet/outlet Ø Hydraulic connections - Condensate discharge F Ø MODEL COOLING CPCITY (1) Total Sensible SHR / Condenser water flow rate Condenser pressure drop kpa Supply fans n. ir flow m3/h Compressors Quantity n. Capacity steps n. ir filters n. Efficiency Refrigerant Refrigerant charge (2) Gas circuits n. Power supply Max operating current (FL) Unit starting current (LR) Energy efficiency indexes (1) EER / Sound pressure level - ISO 3744 (3) On air intake On front side Net weight Hydraulic connections Condenser water inlet/outlet Ø Hydraulic connections - Condensate discharge F Ø 008 P1 009 P1 011 P1 012 P1 016 P1 018 P1 020 P1 021 P1 023 P1 026 P1 S S S S S S S S S S H1 H1 H1 H1 H2 H2 H2 H3 H3 H3 8,4 9,9 12,0 13,6 17,4 18,1 21,7 22,5 24,1 29,7 7,3 8,5 9,2 9,8 14,7 14,0 15,4 18,1 19,6 21,2 0,87 0,85 0,77 0,72 0,84 0,77 0,71 0,80 0,81 0,71 1,5 1,8 2,2 2,5 3,7 4,0 4,9 5,0 5,0 5,4 1,4 1,7 2,0 2,3 3,0 3,1 3,8 3,9 4,2 5, scroll scroll scroll scroll scroll scroll scroll scroll scroll scroll G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 R410 R410 R410 R410 R410 R410 R410 R410 R410 R410 2,8 2,8 2,9 2,9 3,8 3,8 4,1 4,4 4,8 5, /3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 7,2 8,6 9,7 10,7 12,8 14,4 17,7 20,3 20,3 21,3 30,2 40,2 48,2 45,2 53,4 65,9 76,9 79,3 105,3 99,3 5,64 5,46 5,38 5,35 4,72 4,57 4,46 4,49 4,78 5,46 49,0 52,0 52,0 52,0 54,0 54,0 54,0 55,0 55,0 55,0 54,0 58,0 588,0 58,0 60,0 60,0 60,0 60,0 60,0 60, " 1" 1" 1" 1" 1/2 1" 1/2 1" 1/2 1" 1/2 1" 1/2 1" 1/2 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 029 P1 034 P1 037 P1 043 P1 046 P1 S S S S S H3 H3S H3S H3L H3L 31,0 40,2 43,9 47,2 51,4 22,3 28,5 29,9 35,7 37,3 0,72 0,71 0,68 0,76 0,73 6,3 7,0 7,9 8,1 9,2 5,3 6,7 7,4 7,9 8, scroll scroll scroll scroll scroll G4 G4 G4 G4 G4 R410 R410 R410 R410 R410 5,8 6,6 6,6 9,4 9, /3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 26,6 27,1 30,2 35,3 41,6 115,3 121,8 121,8 126,6 148,6 4,91 5,76 5,59 5,81 5,58 55,0 56,0 56,0 56,0 56,0 60,0 62,0 62,0 62,0 62, " 1/2 2" 2" 2" 2" 1/2" 1/2" 1/2" 1/2" 1/2" THE COOLING CPCITY DOES NOT CONSIDER THE SUPPLY FN MOTOR THERML LOD 1. Characteristics referred to entering air at 28 C-50%RH; water to the condenser C 2. Unit refrigerant charge optional excluded. 3. Noise level at 1 meter in free field (external static pressure 50 Pa) TECHNICL DT - OPTIONL CCESSORIES - NEXT DW DL NEXT DW DL Electric heater Capacity Capacity steps n. Humidifier Steam capacity /h Power input 008 P1 009 P1 011 P1 012 P1 016 P1 018 P1 020 P1 021 P1 023 P1 026 P1 029 P1 034 P1 037 P1 043 P1 046 P1 S S S S S S S S S S S S S S S H1 H1 H1 H1 H2 H2 H2 H3 H3 H3 H3 H3S H3S H3L H3L 5,1 5,1 5,1 5,1 5,1 5,1 5,1 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6, ,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2, fiftycoolyears RCGROUP Sp G_ITC_RCW8.4 81

82 NEXT DL IT Cooling TECHNICL DT - NEXT CW DL MODEL COOLING CPCITY (1) Total Sensible SHR / Supply fans n. ir flow m 3 /h ir filters n. Efficiency Power supply Max operating current (FL) Sound level - ISO 3744 (2) On air intake On front side Net weight Connections Chilled water inlet/outlet Ø Condensate discharge - Rubber pipe F Ø H1 H2 H3 H3S H3L 14,1 19,9 29,2 36,8 49,2 13,4 19,2 27,9 35,4 47,6 0,95 0,96 0,96 0,96 0,97 0,2 0,29 0,42 0,57 0, G4 G4 G4 G4 G4 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 2,3 2,0 4,1 4,0 9,0 58,2 60,2 60,9 62,6 66, ,7 59, " 1" 1" 1/4 1 1/2" 1 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" THE COOLING CPCITY DOES NOT CONSIDER THE SUPPLY FN MOTOR THERML LOD 1. Characteristics referred to entering air at 24 C-40%RH with chilled water temperature 7-12 C - 0% glycol. 2. Noise level at 1 meter in free field. TECHNICL DT - OPTIONL CCESSORIES - NEXT CW DL NEXT CW DL Electric heater Capacity Capacity steps n. Humidifier Steam capacity /h Power input H1 H2 H3 H3S H3L 5,1 5,1 6,0 6,0 6, ,3 2,3 2,3 2,3 2,3 NEXT DL DIMENSIONS (mm) a b c H H H H3S H3L c a b 82 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

83 NEXT MTR NEXT MTR: ir conditioners for Metrology Labs with upflow air delivery for matching with remote air cooled condenser (DX) or with built-in water cooled condenser (DW) Cooling capacity: 7 15 NEXT MTR rcgroupairconditioning R407c E C UP FLOW MIN FETURES Precision air conditioner for metrology labs. 10 models available, 2 versions for a wide selection opportunity. vailable in two versions: for matching with remote air cooled condenser (DX) or with built-in water cooled condenser (DW) On/off scroll compressors Single refrigerant circuit. R407C refrigerant charge. EC plug fans. Steam humidifier. Dehumidification system with automatic air flow reduction. 3 working steps electric heater. Upflow air delivery, Over version. Suitable for indoor installation DX version: EER up to 3,92. DW version: EER up to 5,30 Built in water cooled condenser.. INDOOR INSTLLTION The machines are designed for indoor installation. WORKING RNGE The machines are designed to maintain a room temperature between 20 and 26 C (±0.5 C) with a relative humidity between 45 and 55% RH (± 3%). The room has to be closed and with a good thermal insulation as clean rooms, metrology labs, etc. It is possible to extend the operating range from a minimum of 16 C up to a maximum of 32 C with relative humidity from 40 to 60% RH. CUTION: In these operating conditions precision and accuracy of the control are reduced: - Temperature: ± 1 C - Humidity: ± 5%rH. MIN BENEFITS Wide selection opportunity. High precision in maintaining the characteristics of temperature-humidity of the air conditioned room. Humidifier, De-Humidifier, Electric heater supplied as standard. High EER. High efficiency at partial load. Complete set of optional accessories: filters, plenum, panels, stand. Easily of maintenance fiftycoolyears RCGROUP Sp G_ITC_RCW8.4 83

84 NEXT MTR MIN COMPONENTS FRMEWORK Base in aluminium extrusion, painted with epoxy powders. Inner frame and upper frame in aluminium profile, painted with epoxy powders. The inner frame is provided with seals to ensure air tight with the panels. Galvanized steel sheet panels externally coated with PVC film and internally insulated with noise absorption material. The panels are fixed to the frame with non visible mounting system. Electric board in separate technical compartment on the machine front. Colour: RL 9005 for base and frame Similar to RL7015 for panels, with hammered finish ir intake from the front through honeycomb type grille and air delivery from the top. Washable air pre-filters with G2 efficiency, with cells in synthetic fibre. COMPRESSORS Orbiting spiral (SCROLL) hermetic compressors with spiral profile optimized for R407C refrigerant. Continuous control of the cooling capacity by hot gas by-pass. 2-pole 3-phase electric motor with direct on line starting. Crankcase heater. Electric motor thermal protection via internal winding temperature sensors. Terminal box with IP54 enclosure class. Rubber supports. FILTER SECTION Washable air filters with G4 efficiency, with cells in synthetic fibre and metallic frame (EN ). EVPORTING SECTION Heat exchanger coil with internally corrugated copper tubes and high efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops. Cooling capacity control. Frame in galvanized steel. Condensate tray in peraluman with PVC flexible discharge pipe. HETING SECTION 3 working steps electric heater consisting of aluminium armoured elements with integral fins and safety thermostat (binary control logic). Modulating type hot gas reheating system. HUMIDIFICTION SECTION Proportional controlled steam humidifier with immersed electrodes fitted with safety and running accessories. DEHUMIDIFICTION SECTION Dehumidification system with automatic air flow reduction. FNS SECTION Centrifugal fans with backward curved blades, single suction and without scroll housings (Plug-fans), directly coupled to external rotor electric motor. Brushless type synchronous EC motor with integrated electronic commutated system and continuous variation of the rotation speed. The motor rotation control is obtained with the EC system (Electronic Commutation) that manage the motor according to the 0 10V proportional signal coming from the microprocessor control. Temperature/humidity sensors on air intake. IT Cooling REFRIGERNT CIRCUIT Thermostatic expansion valve. Sight glass. Filter dryer on liquid line. Pressure transducers with indication, control and protection functions, on low and high refrigerant pressure. High pressure safety switch with manual reset. Safety valve. Liquid receiver with accessories. 3-way modulating valve for hot gas re-heating system. Check valve for hot gas re-heating system. Hot gas injection valve for capacity control. Balancing valve for hot gas capacity control. Refrigerant circuit with copper tubing with anticondensate insulation of the suction line. Plastic capillary hoses for pressure sensors connection. R407C refrigerant charge. NEXT MTR DX: - Valves on gas delivery and liquid return for coupling to remote air cooled condenser V proportional signal to manage the condensing control system of the remote air cooled condenser. NEXT MTR DW: - Copper brazed plate type with cover plates, plates and connections in ISI 316 stainless steel V proportional signal to manage the condensing control system of the 2-way motorized valve. ELECTRICL PNEL In accordance with EN norms complete with: Main switch with door lock safety. Magnetothermic switch for supply fan, compressor, electric heaters and humidifier. Contactors for each load. The supply fans equipped with EC electric motor are not supplied with contactors. Transformer for auxiliary circuit and microprocessor supply. Panel with machine controls. Power supply: 400/3/50. CONTROL SYSTEM MP.COM microprocessor system with graphic display for control and monitor of operating and alarms status. The system includes: - Voltage free contact for remote general alarm. - Main components hour-meter. - Nonvolatile Flash memory for data storage. - Menu with protection password. - LN connection. TO BE MTCHED WITH REMOTE CONDENSER The DX units are designed to be matched with remote condensers with axial fans (TEM MTE series) or plug-fans (TEM MTE PF series). TEM MTE TEM MTE PF NEXT MTR DX OPTIONL CCESSORIES NEXT MTR DX TEM MTE remote condenser TEM MTE PF remote condenser Liquid solenoid valve Z1 009 Z1 011 Z1 013 Z1 015 Z1 S S S S S H2 H2 H2 H3 H3 available accessory; - not available accessory G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

85 IT Cooling NEXT MTR COMMON OPTIONL CCESSORIES NEXT MTR Electronic expansion valve Compr. power factor capacitor - 0, Phase control relay Noise deading cup on compressor Disposal F5 efficiency air filter Floor stand Hmax=450 mm Condensate discharge system (kit) Sandwich panels Blind frontal pannel Bottom panel Clogged filters alarm 912 -ir flow loss alarm EC Fan Water presence alarm dditional water sensor (kit) Motorized damper with frame ir discharge plenum with grilles Plenum with frontal grille and sound absorber ir supply plenum with F6 filters ir supply plenum with F7 filters ir supply plenum with F9 filters ir supply plenum with sound absorber Outlet air temperature indication Clock card Current indication Voltage indication RC-Com MBUS/JBUS Serial board LON Serial board BCnet MS/TP Serial board BCnet Ethernet - SNMP - TCP/IP Serial board Serial card for GSM Modem Data Logger Driver card Kit modem GSM Plantwatch without modem Remote graphic terminal kit Remote terminal shared RC CLOUD PLTFORM TECHNICL DT - NEXT MTR DX NEXT MTR DX Cooling capacity (1) Total Sensible SHR / (*) Supply fans n. ir flow m 3 /h Nominal external static pressure Pa Max external static pressure Pa Compressors Quantity n. Capacity steps n. ir filters n. Efficiency Refrigerant Refrigerant charge (2) Gas circuits n. Power supply (**) V/Ph/Hz Max operating current (FL) Unit starting current (LR) EER (1) (*) / Sound pressure ISO 3744 (3) On air delivery On air intake Net weight Remote condenser (4) n. TEM MTE STD series Mod. Hot gas reheating system Heating capacity Electric heater Capacity Capacity steps n. Humidifier Steam capacity /h Power input Refrigerant connections Gas delivery ODS Ø Liquid return ODS Ø Connections 007 Z1 009 Z1 011 Z1 013 Z1 015 Z1 S S S S S H2 H2 H2 H3 H3 007 Z1 009 Z1 011 Z1 013 Z1 015 Z1 S S S S S H2 H2 H2 H3 H3 6,7 8,8 9,9 11,5 14,3 6,7 8,8 9,9 11,5 14,3 1,00 1,00 1,00 1,00 1,00 1,78 2,23 2,72 3,21 4, scroll scroll scroll scroll scroll Modulating Modulating Modulating Modulating Modulating G4 G4 G4 G4 G4 R407C R407C R407C R407C R407C 5,4 5,4 5,4 6,8 6, /3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 6,4 7,3 8,6 11,9 15,0 25,9 33,9 41,9 50,3 54,3 3,78 3,92 3,65 3,58 3,21 55,0 59,8 61,6 59,3 65,6 54,4 54,8 55,1 55,9 57, M 11 M 17 M 17 M 17 M 20 Modulating Modulating Modulating Modulating Modulating 7,7 8,4 9,0 10,6 11,9 5,1 5,1 5,1 6,0 6, ,3 2,3 2,3 2,3 2, Humidifier filling F Ø 3/4" 3/4" 3/4" 3/4" 3/4" Condensate discharge - Rubber pipe F Ø 1/2 1/2 1/2 1/2 1/2 THE COOLING CPCITY DOES NOT CONSIDER THE SUPPLY FN MOTOR THERML LOD 1. Characteristics referred to entering air at 24 C-50%RH; 35 C ambient temperature. 2. Unit refrigerant charge. Remote condenser, connections pipes and optional are excluded. 3. Noise level at 1 meter in free field (external static pressure 50 Pa) 4. For matching to other remote air cooled condensers please refer to RC WORLD selection program (*) The value includes the remote condenser as shown in the table. (**) The remote condenser has separated power supply fiftycoolyears RCGROUP Sp G_ITC_RCW8.4 85

86 NEXT MTR IT Cooling TECHNICL DT - NEXT MTR DW MODEL MTR DW Cooling capacity (1) Total Sensible SHR / Condenser water flow rate m 3 /h Condenser pressure drop kpa Supply fans n. ir flow m 3 /h Nominal external static pressure Pa Max external static pressure Pa Compressors Quantity n. Capacity steps n. ir filters n. Efficiency Refrigerant Refrigerant charge (2) Gas circuits n. Power supply V/Ph/Hz Max operating current (FL) Unit starting current (LR) Energy efficiency indexes (1) EER Energy Efficiency Ratio / Sound pressure ISO 3744 (3) On air delivery On air intake Net weight Hot gas reheating system Heating capacity Electric heater Capacity Capacity steps n. Humidifier Steam capacity /h Power input Connections ISO 228/1-G Condenser water inlet/outlet M Ø Humidifier filling F Ø Condensate discharge - Rubber pipe F Ø 007 Z1 009 Z1 011 Z1 013 Z1 015 Z1 S S S S S H2 H2 H2 H3 H3 7,1 9,0 10,3 12,4 15,4 7,1 9,0 10,3 12,4 15,4 1,00 1,00 1,00 1,00 1,00 1,33 1,81 2,20 2,52 3,33 1,2 1,5 1,8 2,1 2, Scroll Scroll Scroll Scroll Scroll Modulating Modulating Modulating Modulating Modulating G4 G4 G4 G4 G4 R407C R407C R407C R407C R407C 5,8 5,8 5,8 7,5 7, /3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 6,4 7,3 8,6 11,9 15,0 25,9 33,9 41,9 50,3 54,3 5,30 4,99 4,68 4,92 4,62 55,0 59,8 61,6 59,3 65,6 54,4 54,8 55,1 55,9 57, Modulating Modulating Modulating Modulating Modulating 7,7 8,4 9,0 10,6 11,9 5,1 5,1 5,1 6,0 6, ,3 2,3 2,3 2,3 2,3 1 1/4" 1 1/4" 1 1/4" 1 1/4" 1 1/4" 3/4" 3/4" 3/4" 3/4" 3/4" 1/2 1/2 1/2 1/2 1/2 THE COOLING CPCITY DOES NOT CONSIDER THE SUPPLY FN MOTOR THERML LOD 1. Characteristics referred to entering air at 24 C-50%RH; water to the condenser C 2. Unit refrigerant charge optional excluded. 3. Noise level at 1 meter in free field (external static pressure 50 Pa) NEXT MTR DIMENSIONS (mm) a b c H H c a b 86 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

87 COOLROW COOL ROW: Direct expansion or chilled water air conditioners for high density racks and blade servers. Cooling Capacity: INVERTER CHILLEDWTER ECFN COOLNET COOLROW rcgroupairconditioning INVERTER R410 CHILLED WTER E C FRONT FLOW MIN FETURES Direct expansion or chilled water feeding air conditioner for high density racks and blade servers. 4 models, 2 versions available for a wide selection opportunity. Plug-fan EC. Frontal air delivery. Suitable for indoor installation. DX VERSION: BLDC inverter scroll compressor. R410 refrigerant charge. EER up to 5,78. Designed for matching with TEM MTE, TEM MTE PF remote condensers. CW VERSION: Chilled water feeding. Two-way chilled water valve. Designed for matching with RC Group liquid chillers INDOOR INSTLLTION The machines are designed for indoor installation. REMOTE CONDENSER The units are designed to be matched with remote condensers with axial fans (TEM MTE series) or plug-fans (TEM MTE PF series). WORKING LIMITS INDOOR UNIT Room air temperature: 14 C minimum temperature with wet bulb 26 C minimum temperature with wet bulb. 40 C maximum temperature with dry bulb. Room air humidity: 20%rH minimum relative humidity. 70%rH maximum relative humidity. MIN BENEFITS Suitable for cooling system for rows of racks (hot/cold aisle or in-row). High EER. BLDC Inverter compressors and plug-fan EC for a higher energy efficiency. vailability of connection on the top or on the bottom of the unit. vailability of chilled water pressure independent characterized control valve (CW version). vailability of extra-circuit coil. Easily of maintenance fiftycoolyears fiftycoolyears RCGROUP Sp G_ITC_RCW8.4 87

88 COOLROW MIN COMPONENTS FRMEWORK Framework in galvanized steel sheet externally painted with epoxy powders. Panels in galvanized steel sheet externally painted with epoxy powders and internal thermal insulation. ccess doors. The doors are equipped with handle with security lock. Holders for unit height adjusting. Colour RL 7016 (anthracite grey) textured. ir flow for cooling system for rows of racks with air intake from the back side through honeycomb type grille and frontal air delivery through honeycomb type grille. FILTER SECTION Washable air filters with G2 efficiency, with cells in synthetic fibre, on air suction panel. FNS SECTION Centrifugal fans with backward curved blades with wing profile, single suction and without scroll housings (Plug-fans), directly coupled to external rotor electric motor. - Impeller in composite material, P6 plastic reinforced with glass-fibre, exempt from rust formation. - Brushless type synchronous EC motor with integrated electronic commutated system and continuous variation of the rotation speed. The motor rotation control is obtained with the EC system (Electronic Commutation) that manage the motor according to the signal coming from the microprocessor control. Fans control through ModBus. Temperature sensor on air delivery. Temperature sensor on air intake. Current detector for loss of air flow alarm through ModBus. Fans quick installation system for a fast replacement. Fan guard IP20 IT Cooling ELECTRICL PNEL Electrical panel, in accordance with EN norms, complete with: Magnetothermic switch on power supply Magnetothermic switches for fans. Magnetothermic switch for compressor (DX version). Transformer for auxiliary circuit and microprocessor supply. Terminals for external enabling, external alarm, general alarm and LN connection. Power supply: 230/1/50. CONTROL SYSTEM Microprocessor system with graphic display for control and monitor of operating and alarms status. The system includes: - Real time clock. - Predisposition for connectivity board housing ( RCcom MBUS/JBUS, LON, BCnet for Ethernet (SNMP- TCP/IP), BCnet for MS/TP). - Main components hour-meter. - Nonvolatile Flash memory for data storage in case of power supply faulty and for alarms status recording (2MB up to 100 alarms). - Menu with protection password. - LN connection. COOLING SECTION Heat exchanger coil with internally corrugated copper tubes and high efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops. Finned pack with hydrophilic treatment that assure the condensate water drop, high thermal conductivity and does not favour the growth of microorganisms. Condensate tray in peraluman with connection (external diameter Ø16) for a discharge tube or for a pump for condensate drain (option). INVERTER DRIVEN COMPRESSOR (series COOLROW DX) scroll compressor BLDC inverter with spiral profile optimized for R410 refrigerant. Synchronous brushless inverter driven motor. Inverter for modulating capacity control. Reactance for the reduction of electromagnetic noise and interference. Crankcase heater. Rubber supports. Soundproof cap. REFRIGERNT CIRCUIT (series COOLROW DX) Electronic expansion valve. Pressure transducers with indication, control and protection functions, on low and high refrigerant pressure. High pressure safety switch with manual reset. Refrigerant temperature sensor for expansion valve. Filter dryer on liquid line. Oil separator on gas discharge. Refrigerant circuit with copper tubing with anticondensate insulation. Rotalock valves on liquid and suction line placed on bottom side of the unit for coupling to remote condenser unit. 0 10V proportional signal to manage the condensing control system of the remote air cooled condenser. R410 refrigerant charge and lubricant oil type PVE (Polyvinyl ether). TO BE MTCHED WITH REMOTE CONDENSER The DX units are designed to be matched with remote condensers with axial fans (TEM MTE series) or plug-fans (TEM MTE PF series). COOLING SECTION (Series COOLROW CW) 2-way motorized valve for water flow regulation with 0 10 VDC control actuator and emergency manual control. Nominal operating pressure up to 1600 kpa and closing pressure (Δps) of 1400 kpa. TEM MTE TEM MTE PF 88 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

89 IT Cooling COOLROW OPTIONL CCESSORIES - COOLROW DX Inv OPTIONL CCESSORIES - COOLROW CW MODEL Unit handling kit Electric heater Steam humidifier Dehumification system Extra-Circuit system Condensate discharge pump G4 Filters Chilled water connections from the top H 2 0 Deviation valve (3 way) Pressure independent Two-way chilled water valve Clogged filters alarm Water presence alarm dditional water sensor (kit) T/rH sensor on air return T/rH remote sensor Differential air pressure control Dual power supply Temporary microprocessor supply RC-Com MBUS/JBUS Serial board LON Serial board BCnet Ethernet - SNMP - TCP/IP Serial board BCnet MS/TP Serial board Doble serial interface Power supply with cable (3m) and IP44 IEC 309 plug Kit modem GSM Plantwatch without modem Remote graphic terminal kit Remote terminal shared Software dvanced - COOLNET RC CLOUD PLTFORM MODEL TEM MTE remote condenser TEM MTE PF remote condenser 213 -TEM MTE electrical power supply by internal unit Unit handling kit Electric heater Steam humidifier Dehumification system Extra-Circuit system Condensate discharge pump G4 Filters Refrigerant connection from the top - DX Clogged filters alarm Water presence alarm dditional water sensor (kit) T/rH sensor on air return T/rH remote sensor Differential air pressure control Dual power supply Temporary microprocessor supply RC-Com MBUS/JBUS Serial board LON Serial board BCnet Ethernet - SNMP - TCP/IP Serial board BCnet MS/TP Serial board Doble serial interface Remote terminal shared Kit modem GSM Plantwatch without modem Remote graphic terminal kit RC CLOUD PLTFORM B6 BF B6 BF B6 BF B6 BF - available accessory; - not available accessory TECHNICL DT - COOL ROW DX Inv COOLROW DX Inv COOLING CPCITY (1) Total Sensible SHR / (*) Supply fans n. ir flow m 3 /h Compressors Quantity n. Capacity steps n. ir filters n. Efficiency Refrigerant Refrigerant charge (2) Gas circuits n. Power supply (**) V/Ph/Hz Max operating current (FL) (*) Unit starting current (LR) Energy efficiency indexes (1) Energy Efficiency Ratio - EER (3) (*) / Sound pressure level - ISO 3744 (4) On front side Net weight Remote condenser (5) n. TEM MTE n. x Mod. Refrigerant connections Gas delivery ODS Ø Liquid return ODS Ø B6 BF B6 BF Min Nom Max Min Nom Max 14,4 23,1 28,5 18,0 36,5 39,7 14,4 23,1 28,5 18,0 36,5 39,7 1,00 1,00 1,00 1,00 1,00 1,00 2,5 5,3 7,9 3,4 10,7 13, scroll scroll 1 1 MOD MOD 1 1 G2 G2 R410 R410 4,5 4, /3/50+N 400/3/50+N 21,6 30,8 8,4 8,4 5,78 4,34 3,60 5,29 3,40 3,06 43,6 54,9 60,2 48,9 65,4 65, M 35 M THE COOLING CPCITY DOES NOT CONSIDER THE SUPPLY FN MOTOR THERML LOD 1. Characteristics referred to entering air at 24 C-50%RH; 35 C ambient temperature. 2. Unit refrigerant charge. Remote condenser, connections pipes and optional are excluded. 3. The Energy Efficiency Index consider also the remote air cooled condenser as shown in the table. 4. Noise level at 1 meter in free field (external static pressure at nominal conditions) 5. For matching to other remote air cooled condensers please refer to RC WORLD selection program (*) The value includes the remote condenser (**) The remote condenser has separated power supply fiftycoolyears RCGROUP Sp G_ITC_RCW8.4 89

90 COOLROW IT Cooling TECHNICL DT - COOL ROW CW MODEL COOLING CPCITY (1) Total Sensible SHR / Supply fans n. ir flow m 3 /h Cooling coil Water flow rate m 3 /h Pressure drop - coil + valve kpa ir filters n. Efficiency Power supply (**) V/Ph/Hz Max operating current (FL) (*) Sound pressure level - ISO 3744 (2) On front side Net weight Connection Water Inlet / Outlet OD (3) Ø mm Condensate discharge OD (4) Ø mm B6 BF B6 BF 49,7 61,1 49,7 61,1 1,00 1,00 1,13 1, ,5 10, G2 G2 230/1/50 230/1/50 4,62 4,62 66,7 67, ,3 48, THE COOLING CPCITY DOES NOT CONSIDER THE SUPPLY FN MOTOR THERML LOD 1. Characteristics referred to entering air at 35 C-25%RH with chilled water temperature C - 0% glycol. 2. Noise level at 1 meter in free field. 3. Hydraulic connection with grooved end, supplied as standard with flexible joint and adapter pipe. 4. Condensate discharge of the condensate tray. External diameter. TECHNICL DT - OPTIONL CCESSORIES COOL ROW COOL ROW Humidifier Steam capacity Power input Extra circuit coil (1) Total cooling capacity Sensible cooling capacity /h B6 BF B6 BF B6 BF B6 BF ,4 1,4 1,4 1,4 47,5 47,5 47,5-47,5 47,5 47,5-1. Characteristics referred to entering air at 35 C-25%RH with chilled water temperature C - 0% glycol. DIMENSIONS (mm) a b c B6 BF c a b 90 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

91 COOLSIDE EVO DX SYSTEM COOLSIDE EVO DX SYSTEM: Direct expansion air conditioning system for high density racks and blade servers. Cooling Capacity: 4 42 INVERTER ECFN COOLSIDE EVO DX SYSTEM INVERTER rcgroupairconditioning R410 E C FRONT FLOW CLOSED LOOP MIN FETURES Direct expansion air conditioning system for high density racks and blade servers. 6 models, 2 versions available for a wide selection opportunity. 6 combinations (in-room unit-outdoor unit) available. EER up to 4,45. Rotary or Scroll BLDC Inverter compressors. R410 refrigerant charge. EC Plug-fans. F Version, frontal air delivery, L version, side air delivery. Evaporating unit suitable for indoor installation. Motocondensing unit MCI, suitable for outdoor installation. Microchannel condensing coil. MIN BENEFITS High EER. Suitable for direct cooling system (close loops) or cooling system for rows of racks (hot/cold aisle). BLDC Inverter compressors and plug-fan EC for a higher energy efficiency. High energy efficiency at partial loads. vailability of connection on the top or on the bottom of the unit. vailability of dual power supply. vailability of box-server rack. Easily of maintenance. WORKING LIMITS INDOOR UNIT Room air temperature: 14 C minimum temperature with wet bulb 26 C minimum temperature with wet bulb. 40 C maximum temperature with dry bulb. Room air humidity: 20%rH minimum relative humidity. 70%rH maximum relative humidity. OUTDOOR UNIT - IR COOLED MOTOCONDENSING UNIT mbient air temperature: -30 C minimum temperature 45 C maximum temperature fiftycoolyears fiftycoolyears RCGROUP Sp G_ITC_RCW8.4 91

92 COOLSIDE EVO DX SYSTEM COMPONENTS - INDOOR UNIT - COOLSIDE EVO DX FRMEWORK Framework in galvanized steel sheet externally painted with epoxy powders. Panels in galvanized steel sheet externally painted with epoxy powders and internally insulated with noise absorption material. ccess doors. The doors are equipped with handle with security lock. Holders for unit height adjusting. Colour RL 7016 (anthracite grey) textured. ir flow: - Cooling system for rows of racks (in-row) COOLSIDE EVO F : o ir intake from the back side through honeycomb type grille and frontal air delivery through honeycomb type grille. - Direct cooling system of racks (in-rack) COOLSIDE EVO L : o ir intake from side through honeycomb type grille and air delivery from side through honeycomb type grille. FILTER SECTION COOLSIDE EVO F The filter section is not supplied for COOLSIDE EVO L unit. Washable air filters with G2 efficiency, with cells in synthetic fibre, on air suction panel. Differential pressure switch on the air side for clogged filters signal. EVPORTING SECTION Heat exchanger coil with internally corrugated copper tubes and high efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops. Finned pack with hydrophilic treatment that assure the condensate water drop, high thermal conductivity and does not favour the growth of micro-organisms. Condensate tray in peraluman with connection (external diameter Ø16) for a discharge tube or for a pump for condensate drain (option). FNS SECTION Centrifugal fans with backward curved blades, single suction and without scroll housings (Plug-fans), directly coupled to brushless type synchronous EC motor with integrated electronic commutated system and continuous variation of the rotation speed. The motor rotation control is obtained with the EC system (Electronic Commutation) that manage the motor according to the 0 10V proportional signal coming from the microprocessor control. Fans quick installation system for a fast replacement. #2 temperature sensors on air delivery. Temperature sensor on air intake. Current detector for loss of air flow alarm. REFRIGERNT CIRCUIT Electronic expansion valve. Refrigerant pressure transducer for expansion valve. Refrigerant temperature sensor for expansion valve. Filter dryer on liquid line. Refrigerant circuit with copper tubing with anticondensate insulation. Rotalock valves on liquid and suction line placed on bottom side of the unit for coupling to remote motocondensing unit. The COOLSIDE EVO DX 040 (size 6 / B6) is equipped with one Rotalock valve on liquid line and two Rotalock valves on suction lines. The refrigerant connection foresee a single liquid line and a double suction line to ensure the lubricant oil return to the compressor. R 410 refrigerant charge. ELECTRICL PNEL Extractable electrical panel, in accordance with EN norms, complete with: Power supply with 10 plugs. Magnetothermic switch on power supply Terminals for external enabling, smoke/fire alarm, general alarm and LN connection. Power supply: 230/1/50. CONTROL SYSTEM Microprocessor system with graphic display for control and monitor of operating and alarms status. The system includes: - Voltage free contact for remote general alarm. - Main components hour-meter. - Nonvolatile Flash memory for data storage. - Menu with protection password. - LN connection. IT Cooling COMPONENTS - OUTDOOR UNIT - MCI MOTOCONDENSING UNIT FRMEWORK Base, self supporting frame and panelling in steel plate with protective surfaces treatment in compliance with UNI ISO 9227/STMB117 and ISO 7253, and painted with epoxy powders. Colour: RL 9002 COMPRESSOR Motocondensing unit model MCI 10: Twin rotary hermetic compressors BLDC inverter type optimized for R410 refrigerant. Motocondensing unit models MCI 20 / MCI 40: Orbiting spiral (SCROLL) hermetic compressors BLDC inverter type with spiral profile optimized for R410 refrigerant. Common characteristics: Inverter driven brushless type electric motor. Modulating capacity control. Crankcase heater. Terminal box with IP54 enclosure class. Rubber supports. CONDENSING COIL ll-aluminium microchannel heat exchanger coil, specifically developed to provide high heat transfer and lower pressure drops. Moreover microchannel technology reduces the weight of the component and the refrigerant charge. FNS SECTION xial fans with sickle-shaped blades, fan guard and optimized for low noise levels. Brushless type synchronous EC motor with integrated electronic commutated system and continuous variation of the rotation speed. The motor rotation control is obtained with the EC system (Electronic Commutation) that manage the motor according to the 0 10V proportional signal coming from the microprocessor control. IP54 enclosure class. REFRIGERNT CIRCUIT Liquid separator on suction line. Oil separator on delivery line with oil recovery capillary hose. Check valve on gas delivery. Liquid receiver. Filter dryer on liquid line. Sight glass. Pressure transducers with indication, control and protection functions, on low and high refrigerant pressure. High pressure safety switch with manual reset. Refrigerant circuit with copper tubing with anticondensate insulation of the suction line. Rotalock valves for coupling to indoor units: - MCI 10: Rotalock valves for connection to 1 indoor unit - MCI 20: Rotalock valves for connection to 2 indoor units - MCI 40: Rotalock valves for connection to 3 indoor units. In case of connection to a single COOLSIDE EVO DX 040 unit, are available as option the indoor evaporating unit #2 suction line collectors for a single suction line realization. R410 refrigerant charge. ELECTRICL PNEL In accordance with EN norms, suitable for outdoor installation, IP54 enclosure class, complete with: Main switch with door lock safety Inverter to drive the compressor motor. Magnetothermic switch for fans motor protection Magnetothermic switch for inverter protection Transformer for auxiliary circuit and microprocessor supply. Terminals for external enabling and smoke/fire alarm. RJ45 connector for microprocessor terminal connection (the microprocessor terminal is not installed on the unit). Power supply: - 230/1/50 for model MCI /3/50+N for models MCI 20 and MCI 40 CONTROL SYSTEM Microprocessor system with graphic display for control and monitor of operating and alarms status. The system includes: - Voltage free contact for remote general alarm. - Main components hour-meter. - Nonvolatile Flash memory for data storage. - Menu with protection password. - LN connection. 92 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

93 IT Cooling OPTIONL CCESSORIES - COOLSIDE EVO DX COOLSIDE EVO DX BOX-server rack Kit BOX 8 connections cabling Kit BOX 16 connections cabling Baseboard for machine holders Condensate discharge pump Remote temperature sensor Timed stop button kit Connections from the top COOLSIDE EVO DX Kit single suction COOLSIDE humidifier kit Dual power supply Kit modem GSM Plantwatch without modem Remote graphic terminal kit Remote terminal shared RC CLOUD PLTFORM COOLSIDE EVO DX SYSTEM F 3 L B3 F B3 L 3 F 3 L B3 F B3 L 6 F 6 L B6 F B6 L OPTIONL CCESSORIES - MCI MCI Kit MCI low temperature MCI double power supply RC-Com MBUS/JBUS serial board BCnet for Ethernet - SNMP - TCP/IP serial board BCnet for MS/TP serial board LON serial board available accessory; - not available accessory fiftycoolyears RCGROUP Sp G_ITC_RCW8.4 93

94 COOLSIDE EVO DX SYSTEM OPTIONL CCESSORIES - BOX - Server Rack Standard 19 server rack to match to COOLSIDE EVO DX 10 L, COOLSIDE EVO DX 20 L. The system sucks hot air directly from the rear side of the racks, and, once cooled, enters it in the front side of the rack. Thanks to the closed cooling system the electronic equipment contained in racks do not require fans for air circulation. IT Cooling POSSIBLE CONFIGURTIONS MONO SPLIT MONO SPLIT MONO SPLIT DX 10 DX 20 DX 40 MCI 20 MCI 40 MCI 10 COOLSIDE EVO DX MULTI SPLIT DX 10 DX 10 MCI 20 MULTI SPLIT DX 20 DX 20 MCI 40 BOX - SERVER RCK (OPTION) FRMEWORK The rack is a 19 standard type (482,6 mm) - 42U (1,75 inch = 44,45 mm) in galvanized steel sheet externally painted with epoxy powders. Galvanized steel sheet panels externally painted with epoxy powders and internally insulated with noise absorption material. Colour: RL 7016 (anthracite grey) textured. The server - rack is in compliance with IEC /2 norms Maximum load capacity for internal installation ccess doors. The doors are equipped with handle with security lock. - Front door is made of safety glass that allows direct control of the internal equipment - Back door in galvanized steel sheet OPTIONL CCESSORIES Bus bar with maximum load of 96 (7 modules 2 x 3 x 16) and power supply cord. MCI 40 DX 10 DX 10 DX 10 IN-ROW IN-RCK COOLSIDE EVO DX F Frontal air delivery COOLSIDE EVO DX L Side air delivery COOLING SYSTEM FOR ROWS OF RCKS (IN ROW). COOLSIDE EVO DX F COOLSIDE EVO units and the racks are placed in rows that are arranged so as to obtain alternate cold and hot aisles. Electronic equipments contained in racks independently provide to aspire the necessary air for cooling. DIRECT COOLING SYSTEM (IN RCK). COOLSIDE EVO DX L The system sucks hot air directly from the rear side of the racks, and, once cooled, enters it in the front side of the rack. Thanks to the closed cooling system the electronic equipment contained in racks do not require fans for air circulation. 94 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

95 IT Cooling COOLSIDE EVO DX SYSTEM TECHNICL DT - COOLSIDE EVO DX MODEL Cooling Capacity (1) Total Sensible SHR / Fans n. rate m 3 /h ir filters n. Efficiency Refrigerant Evaporating coil volume l Gas circuits n. Power supply V/Ph/Hz Max operating current (FL) Sound pressure level (2) On air delivery COOLSIDE EVO F Irradiated COOLSIDE EVO L Net weight COOLSIDE EVO F COOLSIDE EVO L Refrigerant connections Liquid line ODS Ø Suction line ODS Ø B3 3 - B3 6 B6 Nominal Reduced Medium Maximum Nominal Reduced Medium Maximum Nominal Reduced Medium Maximum 10,1 4,5 8,1 11,1 20,3 10,0 15,0 22,5 41,1 20,0 28,0 41,7 10,1 4,5 8,1 11,1 20,3 10,0 15,0 22,5 41,1 20,0 28,0 41,7 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1, G2 G2 G2 R410 R410 R ,8 5, /1/50 230/1/50 230/1/50 2,3 3,8 7,5 67,6 51,0 61,2 68,3 69,8 53,3 63,4 70,4 72,3 55,4 65,9 72,9 60,9 44,3 54,5 61,6 63,1 46,6 56,7 63,7 65,6 48,7 59,2 66,2 3 = 165 / B3 = = 170 / B3 = = 224 / B6 = = 163 / B3 = = 168 / B3 = = 222 / B6 = x 22 THE COOLING CPCITY DOES NOT CONSIDER THE SUPPLY FNS MOTOR THERML LOD 1. Characteristics referred to entering air at 35 C d.b. (20.1 C w.b.) - unit coupled to a MCI motocondensing unit operating at nominal conditions with equivalent length of refrigerant pipes connecting 3m. 2. Sound pressure level at 1 meter in free field (ISO EN 3744). TECHNICL DT - MCI MODEL Connected COOLSIDE EVO DX units n x modello Cooling capacity (1) KW Compressor Quantity n. Modulating power control % xial fans n. rate Refrigerant Total refrigerant charge (2) Gas circuit n. Power supply V/Ph/Hz Max operating current (FL) Energy efficiency index EER - Energy Efficiency Ratio / Sound level Sound power level [Lw] (3) verage sound pressure level [LPm] [Lpm]1 meter far (4) [Lpm] 5 meters far (4) [Lpm]10 meters far (4) Net weight Refrigerant connections Liquid line n x ODS Ø Suction line n x ODS Ø MCI 10 MCI 20 MCI 20 MCI 40 MCI 40 MCI 40 1 x x x x x x ,1 20,3 21,6 39,9 40,6 41,1 2,3 5,6 5,7 11,9 11,9 11,5 Twin Rotary Scroll Scroll Scroll Scroll Scroll R410 R410 R410 R410 R410 R410 3, /1/50 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 26,3 24,0 24,0 38,5 39,1 38,2 4,45 3,64 3,82 3,36 3,42 3,58 86,2 89,2 89,2 87,9 87,9 87,9 70,4 73,4 73,4 71,8 71,8 71,8 60,1 63,1 63,1 61,7 61,7 61,7 54,7 57,7 57,7 56,4 56,4 56, x 10 2 x 12 2 x 12 3 x 12 3 x 12 3 x 12 (1x16)* 1 x 16 2 x 22 2 x 22 3 x 22 3 x 22 3 x Characteristics referred to ambient temperature at 35 C with indoor units operating at nominal conditions with equivalent length of refrigerant pipes connecting 3m for each unit. 2. Unit refrigerant charge, connection pipes excluded. 3. Sound power level [Lw] according to ISO EN verage sound pressure level [Lpm] 1 meter far according to ISO EN *. For monosplit version (with kit single suction optional accessory) fiftycoolyears RCGROUP Sp G_ITC_RCW8.4 95

96 COOLSIDE EVO DX SYSTEM IT Cooling DIMENSIONS - COOLSIDE EVO DX (mm) SIDE a b c B B B c a b DIMENSIONS - BOX, SERVER-RCK (mm) SIDE a b c BOX BOX B c a b DIMENSIONS (mm) MCI 20 MCI 40 MCI G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

97 COOLSIDE EVO CW COOLSIDE EVO CW: Chilled water air conditioners for high density racks and blade servers. Cooling Capacity: CHILLEDWTER ECFN COOLSIDE EVO CW E C rcgroupairconditioning CHILLED WTER FRONT FLOW CLOSED LOOP MIN FETURES Chilled water air conditioners for high density racks and blade servers. 4 models, 2 versions available for a wide selection opportunity. Synergy with RC Group liquid chillers. Chilled water feeding. EC Plug-fans. F Version, frontal air delivery, L version, side air delivery. Suitable for indoor installation. MIN BENEFITS Suitable for direct cooling system (close loops) or cooling system for rows of racks (hot/cold aisle). Plug-fan EC for a higher energy efficiency. vailability of refrigerant connections on the top or on the bottom of the unit. vailability of dual power supply. vailability of box-server rack. Easily of maintenance. WORKING LIMITS INDOOR UNIT Room air temperature: 14 C minimum temperature with wet bulb 26 C minimum temperature with wet bulb. 40 C maximum temperature with dry bulb. Room air humidity: 20%rH minimum relative humidity. 70%rH maximum relative humidity fiftycoolyears fiftycoolyears RCGROUP Sp G_ITC_RCW8.4 97

98 COOLSIDE EVO CW COMPONENTS FRMEWORK Framework in galvanized steel sheet externally painted with epoxy powders. Panels in galvanized steel sheet externally painted with epoxy powders and internally insulated with noise absorption material. ccess doors. The doors are equipped with handle with security lock. Holders for unit height adjusting. Colour: - RL 7016 (anthracite grey) textured. ir flow: - 3 / 6 size Cooling system for rows of racks (in-row): o ir intake from the back side through honeycomb type grille and frontal air delivery through honeycomb type grille. - B3 / B6 size Direct cooling system of racks (in-racks): o ir intake from side through honeycomb type grille and air delivery from side through honeycomb type grille. FILTER SECTION COOLSIDE EVO F The filter section is not supplied for COOLSIDE EVO L unit. Washable air filters with G2 efficiency, with cells in synthetic fibre, on air suction panel. Differential pressure switch on the air side for clogged filters signal. COOLING SECTION Heat exchanger coil with internally corrugated copper tubes and high efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops. Finned pack with hydrophilic treatment that assure the condensate water drop, high thermal conductivity and does not favour the growth of microorganisms. 2-way modulating valve for water flow regulation with 0 10V servomotor and emergency manual control. Hydraulic connections arranged for connection from bottom side of the unit. Condensate tray in peraluman with connection (external diameter Ø16) for a discharge tube or for a pump for condensate drain (option). IT Cooling FNS SECTION Centrifugal fans with backward curved blades, single suction and without scroll housings (Plug-fans), directly coupled to brushless type synchronous EC motor with integrated electronic commutated system and continuous variation of the rotation speed. The motor rotation control is obtained with the EC system (Electronic Commutation) that manage the motor according to the 0 10V proportional signal coming from the microprocessor control. Fans quick installation system for a fast replacement. #2 temperature sensors on air delivery. Temperature sensor on air intake. Current detector for loss of air flow alarm. ELECTRICL PNEL Extractable electrical panel, in accordance with EN norms, complete with: Power supply with 10 plugs. Magnetothermic switch on power supply Terminals for external enabling, smoke/fire alarm, general alarm and LN connection. Power supply: 230/1/50 CONTROL SYSTEM Microprocessor system with graphic display for control and monitor of operating and alarms status. The system includes: - Voltage free contact for remote general alarm. - Main components hour-meter. - Non-volatile Flash memory for data storage. - Menu with protection password. - LN connection. OPTIONL CCESSORIES - COOLSIDE EVO CW MODEL BOX-server rack Kit BOX 8 connections cabling Kit BOX 16 connections cabling Baseboard for machine holders Condensate discharge pump Water presence alarm dditional water sensor (kit) Remote temperature sensor Timed stop button kit Three-way valve Connections from the top COOLSIDE EVO CW COOLSIDE humidifier kit Dual power supply RC-Com MBUS/JBUS Serial board LON serial board BCnet Ethernet - SNMP - TCP/IP Serial board BCnet MS/TP Serial board Kit modem GSM Plantwatch without modem Remote graphic terminal kit Remote terminal shared RC CLOUD PLTFORM F 3 L B3 F B3 L 6 F 6 L B6 F B6 L available accessory; - not available accessory 98 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

99 IT Cooling OPTIONL CCESSORIES - BOX - Server Rack Standard 19 server rack to match to COOLSIDE EVO CW 20 L. The system sucks hot air directly from the rear side of the racks, and, once cooled, enters it in the front side of the rack. Thanks to the closed cooling system the electronic equipment contained in racks do not require fans for air circulation. POSSIBLE CONFIGURTIONS LIQUID CHILLER COOLSIDE EVO CW COOLSIDE EVO CW FREE-COOLING LIQUID CHILLER BOX - SERVER RCK (OPTION) FRMEWORK The rack is a 19 standard type (482,6 mm) - 42U (1,75 inch = 44,45 mm) in galvanized steel sheet externally painted with epoxy powders. Galvanized steel sheet panels externally painted with epoxy powders and internally insulated with noise absorption material. Colour: RL 7016 (anthracite grey) textured. The server - rack is in compliance with IEC /2 norms Maximum load capacity for internal installation ccess doors. The doors are equipped with handle with security lock. - Front door is made of safety glass that allows direct control of the internal equipment - Back door in galvanized steel sheet OPTIONL CCESSORIES Bus bar with maximum load of 96 (7 modules 2 x 3 x 16) and power supply cord. IN-ROW IN-RCK COOLSIDE EVO CW F Frontal air delivery COOLING SYSTEM FOR ROWS OF RCKS (IN ROW). COOLSIDE EVO CW F COOLSIDE EVO units and the racks are placed in rows that are arranged so as to obtain alternate cold and hot aisles. Electronic equipments contained in racks independently provide to aspire the necessary air for cooling. COOLSIDE EVO CW L Side air delivery DIRECT COOLING SYSTEM (IN RCK). COOLSIDE EVO CW L The system sucks hot air directly from the rear side of the racks, and, once cooled, enters it in the front side of the rack. Thanks to the closed cooling system the electronic equipment contained in racks do not require fans for air circulation fiftycoolyears RCGROUP Sp G_ITC_RCW8.4 99

100 COOLSIDE EVO CW IT Cooling TECHNICL DT - COOLSIDE EVO CW Model Size Cooling Capacity (1) Total Sensible SHR / Fans n. rate m 3 /h Cooling coil Water flow rate m 3 /h Pressure drop - coil + valve kpa ir filters n. Efficiency Power supply V/Ph/Hz Max operating current (FL) Sound pressure level (2) On air delivery COOLSIDE EVO F Irradiated COOLSIDE EVO L Net weight COOLSIDE EVO F COOLSIDE EVO L Connections - ISO 228/1-B Chilled water inlet / outlet M Ø Condensate discharge (3) Ø B3 6 B6 Nom Med Max Nom Med Max 25,0 19,6 25,5 53,4 41,7 54,8 25,0 19,6 25,5 53,4 41,7 54,8 1,00 1,00 1,00 1,00 1,00 1, ,3 3,4 4,4 9,2 7,2 9,4 42,0 26,6 44,0 58,0 36,5 60,6 1 1 G2 G2 230/1/50 230/1/50 3,6 7,1 69,8 63,4 70,4 72,3 65,9 72,9 63,1 56,7 63,7 65,6 59,2 66,2 3 = 168 / B3 = = 219 / B6 = = 166 / B3 = = 217 / B6 = /4 1 ½ THE COOLING CPCITY DOES NOT CONSIDER THE SUPPLY FNS MOTOR THERML LOD 1. Characteristics referred to entering air at 35 C d.b. (20.1 C w.b.) - chilled water temperature 7/12 C - 0% glycol. 2. Noise pressure level at 1 meter in free field (ISO EN 3744). 3. Condensate discharge of the condensate tray. External diameter. COOLSIDE EVO CW - DIMENSIONS (mm) a b c B B c a b 100 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

101 ENERGY SPLIT ENERGY SPLIT: Split system air conditioners with free-cooling system. Cooling Capacity: 4 15 UPS48VDC FREECOOLING ENERGY SPLIT rcgroupairconditioning R407c SYSTEM FREE COOLING UPS 48VDC FRONT FLOW MIN FETURES Telecommunication split-system air conditioners. Proportional automatic free-cooling system. Three working mode. 8 models available for a wide selection opportunity. verage step of 1,5. Rotary or scroll compressor. R407c refrigerant charge. Supply fans directly coupled to brushless type electric motors. Horizontal or Vertical air flow. Double power supply (Network + 48VDC UPS) Evaporating unit suitable for indoor installation. Moto-condensing unit suitable for outdoor installation. DOUBLE POWER SUPPLY (Network + 48VDC UPC) WORKING LIMITS Room humidity from 20 up to 75% rh Room temperature from 16 up to 35 C mbient temperature from -30 up to 45 C MIN BENEFITS The proprietary software foresees unit working with the lowest noise emission during the night. Working continuity even during black-out periods. utomatic restart of the unit. vailability of electric heater. Easily of maintenance. PROPORTIONL FREE-COOLING SYSTEM The cooling system is totally proportional and allows three working modes: total free-cooling: only fresh air is used to cool the ambient; partial free-cooling: the fresh air is used for a pre-cooling and the compressor or the chilled water are used to balance the load; mechanical cooling: the compressor or the chilled water are used to cool the ambient fiftycoolyears fiftycoolyears RCGROUP Sp G_ITC_RCW

102 ENERGY SPLIT MIN COMPONENTS INDOOR UNIT FRMEWORK Frame in galvanized steel sheet, painted with epoxy powders. Galvanized steel sheet panels painted with epoxy powders, internally insulated with noise absorption material and seals to ensure air tight with the panels. Colour RL 9002 The frame can be installed on the ceiling (horizontal air flow) or wall mounting installation (vertical air flow). FILTER SECTION Washable air filters with G3 efficiency, with cells in synthetic fibre and metallic frame (EN ). EVPORTING SECTION Heat exchanger coil with internally corrugated copper tubes and high efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops. Frame in galvanized steel. Condensate tray in peraluman with PVC flexible discharge pipe. REFRIGERNT CIRCUIT Thermostatic expansion valve. Pressure transducer with indication, control and protection functions, on high pressure. Low pressure safety switch. Refrigerant circuit with copper tubing with anticondensate insulation of the suction line. Refrigerant connection valves on liquid line and suction line. R407C refrigerant charge. SUPPLY FNS SECTION Power supply 48VDC from UPS Double suction centrifugal fans with forward curved vanes directly coupled to external rotor electric motor. Brushless type electric motor with continuous variation of the rotation speed. The motor rotation control is obtained by signal coming from the microprocessor control. Temperature sensor on room air intake Temperature sensor on room air delivery. Grille on room air suction. Double row adjustable grille on air delivery. System for air flow loss alarm DIRECT FREE-COOLING SECTION Power supply 48VDC from UPS Deviating damper on ambient air. Proportional servomotor directly driven by microprocessor control. Grille on ambient air suction. Temperature sensor on ambient air. ELECTRICL PNEL In accordance with EN norms complete with: Double power supply, from network and from UPS 48VDC Models 4 R1, 5 R1, 6 Z1, 7 Z1, 8 Z1: - 230/1/50 power supply for compressor, condenser fan and eventual electric heater. Models 10 Z1, 13 Z1, 15 Z1: - 400/3/50+N power supply for compressor, condenser fan and eventual electric heater. For all models: - 48 VDC power supply from UPS for supply fans, free-cooling damper servomotor, auxiliary circuit and microprocessor control. Magnetothermic switch for 230/1/50 power supply line (from network) Magnetothermic switch for 48VDC power supply line (from UPS) uxiliary circuit 48VDC (from UPS). Contactor for compressor Phases monitoring relay (only models 10.Z1, 13.Z1, 15.Z1) Terminals for General larm 1 Terminals for General larm 2 Wall mounting remote terminal kit that includes containing box, terminal, telephone cable for connection to the unit (length 10m). IT Cooling CONTROL SYSTEM Power supply 48VDC from UPS Microprocessor system with graphic display for control and monitor of operating and alarms status. The system includes: - Real time clock. - Main components hour-meter. - Menu with protection password. - LN connection. - LN function to obtain a low noise unit running. The system works proportionally to the load on the fan rotation speed either of the condenser fan or the supply fan. The system allows a low noise unit running during night time anyway according to the programmed sets. - utomatic restart of the unit in case of power failure OUTDOOR UNIT FRMEWORK Base and frame in galvanized steel sheet, painted with epoxy powders. Colour RL 9002 ON / OFF COMPRESSOR Rotary compressor with rotary vane (model R1) optimized for R407C refrigerant. Scroll compressor (model Z1) with spiral profile optimized for R410 refrigerant. Electric motor with direct on line starting. Rubber supports. REFRIGERNT CIRCUIT Sight glass. Filter dryer on liquid line. Refrigerant circuit with copper tubing with anticondensate insulation of the suction line. Refrigerant connection valves on liquid line and suction line. R407C refrigerant charge and lubricant oil. CONDENSING COIL Heat exchanger coil with high efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops. The combination of two factors, special tubes and fins, allow to optimally combine the following aspects: - Maximum capacity relative to the size of the exchanger. - Minimum charge of refrigerant. - Reduction of the air flow required for the heat exchange. Frame in galvanized steel. CONDENSER FN SECTION xial fan with sickle-shaped blade, fan guard and optimized for low noise levels. External rotor C type electric motor with stepless variable speed for condensing pressure control. IP54 enclosure class. ELECTRICL PNEL In accordance with EN norms, suitable for outdoor installation, complete with: Main switch with door lock safety and remote signalling for open/close switch Terminals for compressor and condenser fan power supply 102 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

103 IT Cooling OPTIONL CCESSORIES ENERGY SPLIT MODEL Electric heater FC system removal detraction Clogged filters alarm RC-Com MBUS/JBUS Serial board Terminal removal detraction BCnet Ethernet - SNMP - TCP/IP Serial board BCnet MS/TP Serial board Fresh air kit ENERGY SPLIT 04 R1 05 R1 06 Z1 08 Z1 09 Z1 11 Z1 13 Z1 16 Z1 S0 XS S1 XS S1 XS S1/S XS S1/S XS S2 XS S2 XS S3 XS TECHNICL DT ENERGY SPLIT Model Size Cooling capacity(1) Total Sensible SHR / 48VDC power supply from UPS Power supply from network Treatment fans n. ir flow m 3 /h Nominal external static pressure Pa Compressors Quantity n. Capacity steps n. Condenser fans n. ir flow m 3 /h ir filter n. Efficiency Refrigerant Total refrigerant charge Gas circuits n. Power supply - in-room unit V/Ph/Hz Power supply - outdoor unit V/Ph/Hz Max operating current (FL) 48VDC power supply from UPS Power supply from network Starting current (LR) 48VDC power supply from UPS Power supply from network EER (1) / Sound pressure - Indoor unit - ISO 3744 (2) Sound pressure - Outdoor unit - ISO 3744 (2) Net weight - Indoor unit Net weight - Outdoor unit Refrigerant connections Liquid line - SE Flare Ø Suction line - SE Flare Ø Hydraulic connections Condensate discharge Ø mm available accessory; - not available accessory 04 R1 05 R1 06 Z1 07 Z1 08 Z1 10 Z1 13 Z1 15 Z1 S0 XS S0 XS S0 XS S1 XS S1 XS S1 XS S2 XS S2 XS 4,2 5,3 6,0 7,0 9,6 11,4 12,8 15,6 3,9 4,9 5,4 6,2 8,3 9,9 12,0 14,2 0,93 0,93 0,90 0,89 0,87 0,87 0,94 0,91 0,31 0,31 0,34 0,44 0,58 0,61 0,65 0,90 0,91 1,39 1,83 1,82 2,12 2,46 3,02 3, Rotary Rotary Scroll Scroll Scroll Scroll Scroll Scroll G3 G3 G3 G3 G3 G3 G3 G3 R407C R407C R407C R407C R407C R407C R407C R407C 2,0 2,0 2,0 2,0 2,0 2,9 3,1 3, /1/50+48VDC 230/1/50+48VDC 230/1/50+48VDC 230/1/50+48VDC 230/1/50+48VDC 230/1/50+48VDC 230/1/50+48VDC 230/1/50+48VDC 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 400/3/50+N 400/3/50+N 400/3/50+N THE COOLING CPCITY DOES NOT CONSIDER THE SUPPLY FNS MOTOR THERML LOD (1) Referred to entering air at 28 C with 40% RH and outdoor air temperature 35 C (2) Sound pressure 1m far in free field according to ISO3744 norm. 5,5 5,5 5,5 7,5 10,3 11,0 11,7 15,0 7,1 10,1 12,1 12,1 15,5 6,9 7,7 9,2 6,0 6,0 6,0 8,0 10,8 11,5 12,2 15,5 23,6 33,6 47,7 47,7 61,7 40,7 46,7 50,2 3,42 3,11 2,75 3,08 3,56 3,71 3,49 3,33 55,0 55,0 55,0 54,0 57,5 61,0 63,0 65,0 55,0 55,0 53,0 53,0 57,0 57,0 57,0 58, /2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 5/8" 5/8" 5/8" 5/8" 3/4" 3/4" 7/8" 7/8" TECHNICL DT - OPTIONL CCESSORIES ENERGY SPLIT MODEL Electric heater Heating capacity Capacity steps n. 04 R1 05 R1 06 Z1 07 Z1 08 Z1 10 Z1 13 Z1 15 Z1 S0 XS S0 XS S0 XS S1 XS S1 XS S1 XS S2 XS S2 XS 1,0 1,0 1,0 3,0 3,0 3,0 3,0 3, fiftycoolyears RCGROUP Sp G_ITC_RCW

104 ENERGY SPLIT IT Cooling DIMENSIONS - INDOOR EVPORTING UNIT (mm) DIMENSIONS - INDOOR EVPORTING UNIT (mm) a b c S S S c b a DIMENSIONS - OUTDOOR MOTO-CONDENSING UNIT (mm) a b c 4R1 5R Z1 8Z Z1 15Z c a b 104 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

105 MINIPC MINIPC: Telecommunication packaged air conditioners with free-cooling system for outdoor installation. Cooling Capacity: 4 19 UPS48VDC FREECOOLING MINIPC rcgroupairconditioning R407c FREE COOLING FRONT FLOW UPS 48VDC MIN FETURES Telecommunication packaged air conditioners. Proportional automatic free-cooling system. Three working mode. 9 models available for a wide selection opportunity. verage step of 1,5. Rotary or scroll compressor. R407c refrigerant charge. Supply fans directly coupled to brushless type electric motors. Horizontal air flow. Double power supply (Network + 48VDC UPS) Suitable for outdoor installation. mechanical cooling: the compressor or the chilled water are used to cool the ambient DOUBLE POWER SUPPLY (Network + 48VDC UPC) WORKING LIMITS Room humidity from 20 up to 75% rh Room temperature from 16 up to 35 C mbient temperature from -30 up to 45 C MIN BENEFITS The proprietary software foresees unit working with the lowest noise emission during the night. Working continuity even during black-out periods. utomatic restart of the unit. vailability of electric heater. Full frontal inspection. Easily of maintenance. PROPORTIONL FREE-COOLING SYSTEM The cooling system is totally proportional and allows three working modes: total free-cooling: only fresh air is used to cool the ambient; partial free-cooling: the fresh air is used for a pre-cooling and the compressor or the chilled water are used to balance the load; fiftycoolyears fiftycoolyears RCGROUP Sp G_ITC_RCW

106 MINIPC MIN COMPONENTS FRMEWORK Base and frame in galvanized steel sheet, painted with epoxy powders. Galvanized steel sheet panels painted with epoxy powders, internally insulated with noise absorption material and seals to ensure air tight with the panels. Panels fixed with safety screws. Total front access for routine maintenance. Colour RL 9002 ON / OFF COMPRESSOR Rotary compressor with rotary vane (model R1) optimized for R407C refrigerant. Scroll compressor (model Z1) with spiral profile optimized for R410 refrigerant. Electric motor with direct on line starting. Rubber supports. FILTER SECTION Washable air filters with G4 efficiency, with cells in synthetic fibre and metallic frame (EN ). EVPORTING SECTION Heat exchanger coil with internally corrugated copper tubes and high efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops. Frame in galvanized steel. Condensate tray in peraluman with PVC flexible discharge pipe. SUPPLY FNS SECTION Power supply 48VDC from UPS xial fans with sickle-shaped blade and fan guard, directly coupled to external rotor electric motor (units size S0, S1, S1S). Double suction centrifugal fans with forward curved vanes directly coupled to external rotor electric motor (units size S2, S3). Brushless type electric motor with continuous variation of the rotation speed. The motor rotation control is obtained by signal coming from the microprocessor control. Temperature sensor on room air intake Temperature sensor on room air delivery. Grille on room air suction. Double row adjustable grille on air delivery. System for air flow loss alarm IT Cooling ELECTRICL PNEL In accordance with EN norms, suitable for outdoor installation, complete with: Double power supply, from network and from UPS 48VDC Units size S0, S1, S1S: - 230/1/50 power supply for compressor, condenser fan and eventual electric heater. Units size S2, S3: - 400/3/50+N power supply for compressor, condenser fan and eventual electric heater. For all units: - 48 VDC power supply from UPS for supply fans, free-cooling damper servomotor, auxiliary circuit and microprocessor control. Magnetothermic switch for 230/1/50 or 400/3/50+N power supply line (from network) Magnetothermic switch for 48VDC power supply line (from UPS) Contactor on compressor. Phases monitoring relay (only S2, S3 units) uxiliary circuit 48VDC (from UPS). Terminals for General larm 1 Terminals for General larm 2 CONTROL SYSTEM Power supply 48VDC from UPS Microprocessor system with graphic display for control and monitor of operating and alarms status. The system includes: - Real time clock. - Main components hour-meter. - Menu with protection password. - LN connection. - LN function to obtain a low noise unit running. The system works proportionally to the load on the fan rotation speed either of the condenser fan or the supply fan. The system allows a low noise unit running during night time anyway according to the programmed sets. - utomatic restart of the unit in case of power failure REFRIGERNT CIRCUIT Thermostatic expansion valve. Sight glass. Filter dryer on liquid line. Pressure transducer with indication, control and protection functions, on high pressure. Low pressure safety switch. Refrigerant circuit with copper tubing with anticondensate insulation of the suction line. R407C refrigerant charge and lubricant oil. CONDENSING COIL Heat exchanger coil with high efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops. The combination of two factors, special tubes and fins, allow to optimally combine the following aspects: - Maximum capacity relative to the size of the exchanger. - Minimum charge of refrigerant. - Reduction of the air flow required for the heat exchange. Frame in galvanized steel. Grille on air suction/discharge. CONDENSER FNS SECTION xial fan with sickle-shaped blade, fan guard and optimized for low noise levels. External rotor C type electric motor with stepless variable speed for condensing pressure control. IP54 enclosure class. DIRECT FREE-COOLING SECTION Power supply 48VDC from UPS Deviating damper on ambient air. Proportional servomotor directly driven by microprocessor control. Grille on ambient air suction. Temperature sensor on ambient air. 106 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

107 IT Cooling OPTIONL CCESSORIES MINIPC MODEL Mounting brackets Electric heater Clogged filters alarm RC-Com MBUS/JBUS Serial board BCnet Ethernet - SNMP - TCP/IP Serial board BCnet MS/TP Serial board MINIPC 04 R1 05 R1 06 Z1 08 Z1 09 Z1 11 Z1 13 Z1 16 Z1 20 Z1 S0 XS S1 XS S1 XS S1/S XS S1/S XS S2 XS S2 XS S3 XS S3 XS available accessory; - not available accessory TECHNICL DT MINIPC MODEL Cooling capacity(1) Total Sensible SHR / 48VDC power supply from UPS Power supply from network Treatment fans n. ir flow m 3 /h Nominal external static pressure Pa Compressors Quantity n. Capacity steps n. Condenser fans n. ir flow m 3 /h ir filter n. Efficiency Refrigerant Total refrigerant charge Gas circuits n. Power supply V/Ph/Hz Max operating current (FL) 48VDC power supply from UPS Power supply from network Starting current (LR) 48VDC power supply from UPS Power supply from network EER (1) / Sound pressure - ISO 3744 (2) On air intake On front side Net weight 04 R1 05 R1 06 Z1 08 Z1 09 Z1 11 Z1 13 Z1 16 Z1 20 Z1 S0 XS S1 XS S1 XS S1/S XS S1/S XS S2 XS S2 XS S3 XS S3 XS 4,2 5,6 6,3 8,6 9,3 11,6 12,4 16,5 18,9 4,2 5,5 6,3 8,2 9,3 11,3 12,4 16,1 18,9 1,00 0,99 1,00 0,96 1,00 0,97 1,00 0,98 1,00 0,11 0,22 0,22 0,39 0,39 0,48 0,63 0,67 1,09 1,18 1,43 1,88 2,21 2,79 3,00 4,00 4,81 6, rotary rotary scroll scroll scroll scroll scroll scroll scroll G4 G4 G4 G4 G4 G4 G4 G4 G4 R407C R407C R407C R407C R407C R407C R407C R407C R407C 1,3 1,6 1,6 1,7 1,7 3,0 3,3 4,0 4, /1/50+48VDC 230/1/50+48VDC 230/1/50+48VDC 230/1/50+48VDC 230/1/50+48VDC 400/3/50+48VDC 400/3/50+48VDC 400/3/50+48VDC 400/3/50+48VDC THE COOLING CPCITY DOES NOT CONSIDER THE SUPPLY FNS MOTOR THERML LOD (1) Referred to entering air at 28 C with 40% RH and outdoor air temperature 35 C (2) Sound pressure 1m far in free field according to ISO3744 norm. 3,7 6,0 6,0 9,7 9,7 11,5 14,6 15,5 24,0 8,6 9,9 12,1 15,5 18,8 8,2 9,2 13,6 19,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 32,6 33,4 47,7 61,7 77,5 47,2 53,2 67,2 104,0 3,29 3,36 3,00 3,30 2,91 3,33 2,68 3,01 2,49 63,0 55,0 55,0 60,0 60,0 64,0 67,0 69,0 71,5 54,0 52,0 57,0 57,0 62,0 58,0 58,0 58,0 64, TECHNICL DT - OPTIONL CCESSORIES MINIPC MODEL Electric heater Heating capacity Capacity steps n. 04 R1 05 R1 06 Z1 08 Z1 09 Z1 11 Z1 13 Z1 16 Z1 20 Z1 S0 XS S1 XS S1 XS S1/S XS S1/S XS S2 XS S2 XS S3 XS S3 XS 1,0 1,5 1,5 1,5 1,5 4,5 4,5 4,5 4, fiftycoolyears RCGROUP Sp G_ITC_RCW

108 MINIPC IT Cooling DIMENSIONS (mm) a b c S S S1S S S c a b 108 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

109 ENERTEL ENERTEL: Telecommunication packaged air conditioners with free-cooling system for indoor installation. Cooling Capacity: 5 15 ENERTEL rcgroupairconditioning R407c R134a FREE COOLING UP FLOW DOWN FLOW DISPL CEMENT UPS 48VDC MIN FETURES Telecommunication packaged air conditioners. Proportional automatic free-cooling system. Three working mode. 22 models, 3 versions available for a wide selection opportunity. verage step of 1,5. Scroll compressor. R407c refrigerant charge, Over version. R134a refrigerant charge, Under version and DL version. Supply centrifugal fans directly coupled to the electric motors. Upflow air delivery (Over version), Downflow air delivery (Under version), Displacement air delivery (DL version). Double power supply (Network + 48VDC UPS) Suitable for indoor installation. compressor or the chilled water are used to balance the load; mechanical cooling: the compressor or the chilled water are used to cool the ambient DOUBLE POWER SUPPLY (Network + 48VDC UPC) WORKING LIMITS Room humidity from 20 up to 75% rh Room temperature from 16 up to 35 C mbient temperature from -30 up to 45 C MIN BENEFITS The proprietary software foresees unit working with the lowest noise emission during the night. Working continuity even during black-out periods. utomatic restart of the unit. vailability of electric heater. Full frontal inspection. Easily of maintenance. PROPORTIONL FREE-COOLING SYSTEM. The cooling system is totally proportional and allows three working modes: total free-cooling: only fresh air is used to cool the ambient; partial free-cooling: the fresh air is used for a pre-cooling and the fiftycoolyears fiftycoolyears RCGROUP Sp G_ITC_RCW

110 ENERTEL MIN COMPONENTS FRMEWORK Galvanized steel sheet base externally painted with epoxy powders. Housing consisting of aluminium profile frame, jointed with reinforced PVC corners and galvanized steel sheet panels externally coated with PVC film. Panels internally insulated by noise absorption material fixed by special PVC gasket, granting also the panels air tightness. The panels are fixed by stainless steel screws contained in a small cage not projecting from the housing. Total front access for routine maintenance. ON / OFF COMPRESSOR Scroll compressor. Electric motor with direct on line starting. Rubber supports. FILTER SECTION Washable air filters with G3 efficiency, with cells in synthetic fibre and metallic frame (EN ). EVPORTING SECTION Heat exchanger coil with internally corrugated copper tubes and high efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops. Frame in galvanized steel. Condensate tray in peraluman with PVC flexible discharge pipe. SUPPLY FNS SECTION Power supply 48VDC from UPS ENERTEL O (Over) Centrifugal fans with backward curved blades, single suction and without scroll housings (Plug-fan), directly coupled to external rotor electric motor. ENERTEL U (Under) ENERTEL DL (Displacement) Double suction centrifugal fans with forward curved vanes directly coupled to external rotor electric motor. FOR LL SERIES Brushless type electric motor with continuous variation of the rotation speed. The motor rotation control is obtained by signal coming from the microprocessor control. Temperature sensor on room air intake Temperature sensor on room air delivery. Grille on room air suction. Double row adjustable grille on air delivery (ENERTEL O). System for air flow loss alarm ir delivery: o ENERTEL U: Downflow air delivery for raised floor o ENERTEL O. Frontal air delivery or upflow air delivery o ENERTEL DL: Displacement air delivery DIRECT FREE-COOLING SECTION Power supply 48VDC from UPS Deviating damper on ambient air. Proportional servomotor directly driven by microprocessor control. Grille on ambient air suction. Temperature sensor on ambient air. IT Cooling ELECTRICL PNEL In accordance with EN norms, suitable for outdoor installation, complete with: Double power supply, from network and from UPS 48VDC Units size S1: - 230/1/50 power supply for compressor, condenser fan and eventual electric heater. Units size S2, S3: - 400/3/50+N power supply for compressor, condenser fan and eventual electric heater. For all units: - 48 VDC power supply from UPS for supply fans, free-cooling damper servomotor, auxiliary circuit and microprocessor control. Magnetothermic switch for 230/1/50 or 400/3/50+N power supply line (from network) Magnetothermic switch for 48VDC power supply line (from UPS) Contactor on compressor. Phases monitoring relay (only S2, S3 units) uxiliary circuit 48VDC (from UPS). Terminals for General larm 1 Terminals for General larm 2 CONTROL SYSTEM Power supply 48VDC from UPS Microprocessor system with graphic display for control and monitor of operating and alarms status. The system includes: - Real time clock. - Main components hour-meter. - Menu with protection password. - LN connection. - LN function to obtain a low noise unit running. The system works proportionally to the load on the fan rotation speed either of the condenser fan or the supply fan. The system allows a low noise unit running during night time anyway according to the programmed sets. - utomatic restart of the unit in case of power failure REFRIGERNT CIRCUIT Thermostatic expansion valve. Sight glass. Filter dryer on liquid line. Pressure transducer with indication, control and protection functions, on high pressure. Low pressure safety switch. Refrigerant circuit with copper tubing with anticondensate insulation of the suction line. ENERTEL O (Over) R407C refrigerant charge and lubricant oil. ENERTEL U (Under) ENERTEL DL (Displacement) R134a refrigerant charge and lubricant oil. CONDENSING COIL Heat exchanger coil with high efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops. The combination of two factors, special tubes and fins, allow to optimally combine the following aspects: - Maximum capacity relative to the size of the exchanger. - Minimum charge of refrigerant. - Reduction of the air flow required for the heat exchange. Frame in galvanized steel. Grille on air suction/discharge. CONDENSER FNS SECTION Double suction centrifugal fans with forward curved vanes directly coupled to external rotor electric motor. External rotor C type electric motor with stepless variable speed for condensing pressure control. 110 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

111 IT Cooling OPTIONL CCESSORIES - ENERTEL O ENERTEL O MODEL Electric heater Clogged filters alarm Clock card RC-Com MBUS/JBUS Serial board BCnet Ethernet - SNMP - TCP/IP Serial board BCnet MS/TP Serial board Fresh air kit Fresh air kit with plenum ENERTEL 05 Z1 06 Z1 07 Z1 08 Z1 10 Z1 11 Z1 13 Z1 15 Z1 S1 XS S1 XS S1 XS S2 XS S2 XS S2 XS S3 XS S3 XS OPTIONL CCESSORIES - ENERTEL U / DL ENERTEL U/DL MODEL Electric heater Clogged filters alarm Clock card RC-Com MBUS/JBUS Serial board BCnet Ethernet - SNMP - TCP/IP Serial board BCnet MS/TP Serial board Fresh air kit Fresh air kit with plenum Horizontal discharge TECHNICL DT - ENERTEL O ENERTEL O MODEL Cooling capacity(1) Total Sensible SHR / 48VDC power supply from UPS Power supply from network Treatment fans n. ir flow m 3 /h Fans max external static pressure Pa Compressors Quantity n. Capacity steps n. Condenser fans n. ir flow m 3 /h Max external static pressure ir filter n. Efficiency Refrigerant Total refrigerant charge Gas circuits n. Power supply Max operating current (FL) 48VDC power supply from UPS Power supply from network Starting current (LR) 48VDC power supply from UPS Power supply from network EER (1) Sound pressure - ISO 3744 (2) On air intake On front side Net weight Pa / 06 Q1 07 Q1 08 Q1 09 Q1 10 Q1 13 Q1 15 Q1 S1 XS S1 XS S1 XS S2 XS S2 XS S3 XS S3 XS available accessory; - not available accessory 05 Z1 06 Z1 07 Z1 08 Z1 10 Z1 11 Z1 13 Z1 15 Z1 S1 XS S1 XS S1 XS S2 XS S2 XS S2 XS S3 XS S3 XS 5,4 6,1 7,0 10,0 11,0 12,2 14,4 15,4 5,4 6,1 7,0 9,4 10,4 11,5 14,3 15,2 1,00 1,00 1,00 0,94 0,95 0,94 0,99 0,99 0,12 0,12 0,12 0,24 0,24 0,23 0,23 0,23 1,80 2,18 2,76 2,87 3,35 3,74 4,52 5, scroll scroll scroll scroll scroll scroll scroll scroll G3 G3 G3 G3 G3 G3 G3 G3 R407C R407C R407C R407C R407C R407C R407C R407C 2,2 2,2 2,2 3,5 3,5 3,7 5,0 5, /1/50+48VDC 230/1/50+48VDC 230/1/50+48VDC 400/3/50+N +48VDC 400/3/50+N +48VDC 400/3/50+N +48VDC 400/3/50+N +48VDC 400/3/50+N + 48VDC THE COOLING CPCITY DOES NOT CONSIDER THE SUPPLY FNS MOTOR THERML LOD (1) Referred to entering air at 28 C with 40% RH and outdoor air temperature 35 C (2) Sound pressure 1m far in free field according to ISO3744 norm. 4,0 4,0 4,0 6,5 6,5 6,5 6,5 6,5 11,0 14,0 17,4 10,1 11,2 12,0 13,2 17,6 1,0 1,0 1,0 3,0 2,0 2,0 2,0 2,0 37,6 49,6 63,6 37,0 45,0 51,0 57,2 71,2 2,83 2,63 2,42 3,21 3,06 3,07 3,03 2,70 62,0 62,0 62,0 65,0 65,0 65,0 65,0 65,0 65,0 65,0 65,0 68,0 68,0 68,0 68,0 68, TECHNICL DT - ENERTEL O - OPTIONL CCESSORIES ENERTEL O MODEL Electric heater Heating capacity Capacity steps n. 05 Z1 06 Z1 07 Z1 08 Z1 10 Z1 11 Z1 13 Z1 15 Z1 S1 XS S1 XS S1 XS S2 XS S2 XS S2 XS S3 XS S3 XS 1,7 1,7 1,7 4,5 4,5 4,5 4,5 4, fiftycoolyears RCGROUP Sp G_ITC_RCW

112 ENERTEL IT Cooling TECHNICL DT - ENERTEL U/DL ENERTEL U/DL MODEL Cooling capacity(1) Total Sensible SHR / 48VDC power supply from UPS Power supply from network Treatment fans n. ir flow m3/h Fans max external static pressure Pa Compressors Quantity n. Capacity steps n. Condenser fans n. ir flow m 3 /h Max external static pressure Pa ir filter n. Efficiency Refrigerant Total refrigerant charge Gas circuits n. Power supply Max operating current (FL) 48VDC power supply from UPS Power supply from network Starting current (LR) 48VDC power supply from UPS Power supply from network EER Sound pressure - ISO 3744 (2) On air intake On front side Net weight / 06 Q1 07 Q1 08 Q1 10 Q1 11 Q1 13 Q1 15 Q1 S1 XS S1 XS S1 XS S2 XS S2 XS S3 XS S3 XS 6,5 7,3 7,8 9,9 10,8 14,7 15,4 6,0 6,7 7,2 9,1 10,3 13,7 14,6 0,92 0,92 0,93 0,92 0,95 0,93 0,95 0,3 0,3 0,3 0,3 0,3 0,6 0,6 1,9 2,2 2,6 3,0 3,7 4,5 5, scroll scroll scroll scroll scroll scroll scroll G3 G3 G3 G3 G3 G3 G3 R134a R134a R134a R134a R134a R134a R134a 2,2 2,2 2,2 3,5 3,5 5,0 5, /1/50+48VDC 230/1/50+48VDC 230/1/50+48VDC 400/3/50+N +48VDC 400/3/50+N +48VDC 400/3/50+N +48VDC 400/3/50+N +48VDC 7,7 7,7 7,7 8,5 8,5 15,0 15,0 17,4 19,9 25,7 10,8 15,2 18,5 21,0 1,0 1,0 1,0 2,0 2,0 2,0 2,0 63,6 78,6 102,6 51,8 68,8 79,0 106,0 3,00 2,97 2,67 2,93 2,67 2,90 2,73 51,0 54,0 54,0 55,0 55,0 57,0 57,0 63,0 65,0 65,0 65,0 65,0 68,0 68, THE COOLING CPCITY DOES NOT CONSIDER THE SUPPLY FNS MOTOR THERML LOD (1) Referred to entering air at 28 C with 40% RH and outdoor air temperature 35 C (2) Sound pressure 1m far in free field according to ISO3744 norm. TECHNICL DT - ENERTEL U/DL - OPTIONL CCESSORIES ENERTEL U/DL MODEL Electric heater Heating capacity Capacity steps n. 06 Q1 07 Q1 08 Q1 10 Q1 11 Q1 13 Q1 15 Q1 S1 XS S1 XS S1 XS S2 XS S2 XS S3 XS S3 XS 3,0 3,0 3,0 3,0 3,0 4,5 4, DIMENSIONS - ENERTEL O (mm) a b c S S S c DIMENSIONS - ENERTEL DL, ENERTEL U (mm) a b c S S S a b 112 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

113 INVERTER MRK MRK: Telecommunication packaged air conditioners with free-cooling system for indoor or outdoor installation. Cooling Capacity: 5,8 9,1 UPS48VDC FREECOOLING MRK rcgroupairconditioning INVERTER R410 FREE COOLING FRONT FLOW UPS 48VDC MIN FETURES Telecommunication packaged air conditioners. Proportional automatic free-cooling system. Three working mode. 3 models available for a wide selection opportunity. Modulating cooling capacity control. Rotary or On/off or BLDC scroll compressor. EER up to 4,3. R410 refrigerant charge. EC plug-fans. Horizontal air flow. Double power supply (Network + 48VDC UPS) Suitable for indoor or outdoor installation. MIN BENEFITS The proprietary software foresees unit working with the lowest noise emission during the night. Working continuity even during black-out periods. utomatic restart of the unit. BLDC Inverter scroll compressor and EC plug-fans for a higher energy efficiency. vailability of electric heater. Choice between indoor and outdoor installation. Free-cooling operation with +45% of air flow compared to the mechanical cooling operation. This allows to transfer more cooling power to the air conditioned room, maximizing energy savings. Easily of maintenance. SUITBLE FOR INDOOR OR OUTDOOR INSTLLTION FREE-COOLING SYSTEM Proportional free-cooling system The free-cooling system does not require the installation of overpressure damper or air expulsion system, into the room. The layout of the unit allows the expulsion of air injected with the free-cooling system directly from the machine. DOUBLE POWER SUPPLY (Network + 48VDC UPC) WORKING LIMITS Room humidity from 20 up to 75% rh Room temperature from 10 up to 42 C mbient temperature from -20 up to 42 C fiftycoolyears fiftycoolyears RCGROUP Sp G_ITC_RCW

114 MRK MIN COMPONENTS FRMEWORK Base and frame in galvanized steel sheet, painted with epoxy powders. Galvanized steel sheet panels painted with epoxy powders, internally insulated with noise absorption material and seals to ensure air tight with the panels. Panels fixed with safety screws. Total front access for routine maintenance. Brackets for unit wall mounting. Colour RL 9002 ON / OFF COMPRESSOR MRK 06 Rotary compressor with rotary vane optimized for R410 refrigerant. Electric motor with direct on line starting. Rubber supports. MRK 09 Scroll compressor with spiral profile optimized for R410 refrigerant. Electric motor with direct on line starting. Rubber supports. INVERTER DRIVEN COMPRESSOR MRK 10 INV scroll compressor BLDC inverter with spiral profile optimized for R410 refrigerant. Synchronous brushless inverter driven motor. Inverter for modulating capacity control. Reactance for the reduction of electromagnetic noise and interference. Crankcase heater. Rubber supports. Soundproof cap. FILTER SECTION Washable air filters with G4 efficiency, with cells in synthetic fibre and metallic frame (EN ). EVPORTING SECTION Heat exchanger coil with internally corrugated copper tubes and high efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops. Frame in galvanized steel. Condensate tray in peraluman with PVC flexible discharge pipe. SUPPLY FNS SECTION Power supply 48VDC from UPS Centrifugal fans with backward curved blade, single suction and without scroll housings (Plug-fan), directly coupled to external rotor electric motor. - Impeller in aluminium exempt from rust formation. - Brushless type synchronous EC motor with integrated electronic commutated system and continuous variation of the rotation speed. The motor rotation control is obtained with the EC system (Electronic Commutation) that manage the motor according to the signal coming from the microprocessor control. Temperature sensor on room air intake Temperature sensor on room air delivery. Grille on room air suction. Grille on room air delivery. System for air flow loss alarm REFRIGERNT CIRCUIT Thermostatic expansion valve for models MRK 06 and MRK 09. Electronic expansion valve for model MRK 10 INV Sight glass. Filter dryer on liquid line. Pressure transducer with indication, control, protection and limit functions on high pressure. Pressure transducer with indication, control and protection functions on low pressure. Refrigerant circuit with copper tubing with anticondensate insulation of the suction line. R410 refrigerant charge and lubricant oil - Maximum capacity relative to the size of the exchanger. - Minimum charge of refrigerant. - Reduction of the air flow required for the heat exchange. Frame in galvanized steel. Grille on air suction/discharge. IT Cooling CONDENSER FNS SECTION Power supply 48VDC from UPS Centrifugal fans with backward curved blades, single suction and without scroll housings (Plug-fan), directly coupled to external rotor electric motor. - Impeller in aluminium exempt from rust formation. - Brushless type synchronous EC motor with integrated electronic commutated system and continuous variation of the rotation speed. The motor rotation control is obtained with the EC system (Electronic Commutation) that manage the motor according to the signal coming from the microprocessor control. DIRECT FREE-COOLING SECTION Power supply 48VDC from UPS Deviating damper on ambient air. Proportional servomotor directly driven by microprocessor control. Grille on ambient air suction. Temperature sensor on ambient air. The free-cooling system does not require the installation of overpressure damper or air expulsion system, into the room. ELECTRICL PNEL In accordance with EN norms, suitable for outdoor installation, complete with: Double power supply, from network and from UPS 48VDC MRK 06 MRK 10 INV: - 230/1/50 power supply for compressor and eventual electric heater. MRK 09: - 400/3/50 power supply for compressor and eventual electric heater. For all units: - 48 VDC power supply from UPS for supply fan, condenser fan, freecooling damper servomotor, auxiliary circuit and microprocessor control. Magnetothermic switch for 230/1/50 or 400/3/50 power supply line (from network) Magnetothermic switch for 48VDC power supply line (from UPS) Contactor on compressor (models MRK 06 and MRK 09) Phases monitoring relay (model MRK 09) uxiliary circuit 48VDC (from UPS). Terminals for General larm CONTROL SYSTEM Power supply 48VDC from UPS Microprocessor system for control and monitor of operating and alarms status. The system includes: - 8-line remote display with keyboard. The display is supplied with a cable for connection to the controller and integrated magnetic plate. IP65 class protection. - Real time clock. - Main components hour-meter. - Menu with protection password. - Integrated Ethernet port - utomatic restart of the unit in case of power failure - LN function to obtain a low noise unit running. The system works proportionally to the load on the fan rotation speed either of the condenser fan or the supply fan. The system allows a low noise unit running during night time anyway according to the programmed sets. - IO (ll In One) function of the Free-Cooling system. During free-cooling operation are used at the same time the supply fan and the condenser fan at higher speeds (+45% of air flow) compared to the mechanical cooling operation. This allows to transfer more cooling power to the air conditioned room, maximizing energy savings. The layout of the unit allows the expulsion of air injected with the freecooling system directly from the machine avoiding the installation of overpressure damper. - NBC (No Break Cooling) function to ensure continuity of cooling in alarm condition. The free-cooling system automatically activates the case of alarm / lock of the compressor or black-out of the electricity grid. CONDENSING COIL Heat exchanger coil with high efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops. The combination of two factors, special tubes and fins, allow to optimally combine the following aspects: 114 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

115 IT Cooling OPTIONL CCESSORIES - MRK MRK MODEL Electric heater Clogged filters alarm ir flow loss alarm EC fan Indoor installation Electronic expansion valve INV - MRK TECHNICL DT Model Cooling capacity(1) Total Sensible SHR / Treatment fans n. ir flow Compressors Quantity n. Capacity steps n. Condenser fans n. ir flow Refrigerant Total refrigerant charge Kg Gas circuits n. Power supply V/Ph/Hz Max operating current (FL) Starting current (LR) EER (1) / Sound pressure - ISO 3744 (2) In-room side mbient side Net weight Kg available accessory; - not available accessory INV 10 INV 10 INV min nom max 5,8 9,0 4,3 7,1 9,1 5,8 9,0 4,3 7,1 9,1 1,0 1,0 1,0 1,0 1,0 1,9 3,2 1,0 1,9 3, rotary scroll scoll inverter scroll inverter scroll inverter MOD MOD MOD R410 R410 R410 R410 R410 1,7 1,7 1,7 1,7 1, VDC VDC VDC VDC VDC 20,6 29,6 45,3 45,3 45, ,2 24,2 24,2 24,2 3,06 2,79 4,30 3,65 2,64 THE COOLING CPCITY DOES NOT CONSIDER THE SUPPLY FNS MOTOR THERML LOD (1) Referred to entering air at 30 C with 35% RH and outdoor air temperature 35 C (2) Sound pressure 1m far in free field according to ISO3744 norm. 42,8 52,6 52,6 52,6 52,6 53,7 62,3 62,3 62,3 62, OPERTING PRINCIPLE - OUTDOOR INSTLLTION FREE - COOLING MECHNICL COOLING + FREE - COOLING MECHNICL COOLING OUTDOOR INDOOR OUTDOOR INDOOR OUTDOOR INDOOR fiftycoolyears RCGROUP Sp G_ITC_RCW

116 MRK IT Cooling OPERTING PRINCIPLE - INDOOR INSTLLTION FREE - COOLING MECHNICL COOLING + FREE - COOLING MECHNICL COOLING OUTDOOR INDOOR OUTDOOR INDOOR OUTDOOR INDOOR DIMENSIONS (mm) a b c MRK c a b 116 Technical data and dimensions are not binding. RC GROUP S.p.. reserves the right for G_ITC_RCW8.4 changes and / or modifi RCGROUP cations Sp without notice. fiftycoolyears

117 MXIMO MXIMO: Packaged air cooled liquid chillers with free-cooling system for outdoor installation, equipped with scroll compressors and axial fans Cooling Capacity: Free-Cooling Capacity: FREECOOLING MXIMO rcgroupairconditioning R410 FREE COOLING PLTE E C MIN FETURES ir cooled liquid chiller with free-cooling system. 29 models available, for a wide selection opportunity. verage step of 12,5. EER up to 2,92. ESEER up to 3,80. Scroll compressors. R410 Refrigerant charge. Single or double refrigerant circuit. Plate type heat exchangers. EC xial fans. Single air circuit. Electronic expansion valve. Suitable for outdoor installation. MIN BENEFITS Units equipped with two scroll compressors for refrigerant circuit to reach a high efficiency. Units with single and double refrigerant circuits. Indirect free cooling system. High EER and ESEER. EC axial fans for a high efficiency. vailability of kit for the reduction and the extreme reduction of the noise. vailability of pumping groups. vailability of partial heat recovery system. Easily of maintenance. Complete set of components dedicated to the safety of the unity. Eurovent Certification. INDIRECT FREE COOLING SYSTEM Complete cooling of the chilled water of the existing cooling system with the outside air. The energy saving will be higher the longer the outside temperature remains below the required temperature for cooling. FNS WITH BRUSHLESS TYPE EC MOTOR These electric motors are ensuring high performances, minimum energy consumption and total absence of electromagnetic noise WORKING LIMITS IN COOLING MODE Chilled water outlet temperature: 4 15 C mbient temperature: C WORKING LIMITS IN FREE-COOLING MODE Minimum chilled water outlet temperature: -15 C Minimum ambient temperature: -20 C fiftycoolyears fiftycoolyears RCGROUP Sp G_ITC_RCW

118 MXIMO MIN COMPONENTS FRMEWORK Base, self supporting frame and panelling in steel plate with protective surfaces treatment in compliance with UNI ISO 9227/STMB117 and ISO 7253, and painted with epoxy powders. Colour: RL 9002 COMPRESSORS Orbiting spiral (SCROLL) hermetic compressors with spiral profile optimized for R410 refrigerant. ON / OFF capacity control (0 / 100% each compressor). 2-pole 3-phase electric motor with direct on line starting. Phase sequence electronic relay. Crankcase heater. Electric motor thermal protection via internal winding temperature sensors. Rubber supports. EVPORTOR Copper brazed plate type with cover plates, plates and connections in ISI 316 stainless steel: - With single refrigerant circuit for S version machines. - With double refrigerant circuit for D version machines. nticondensate insulation made of polyurethane. Temperature sensors on water inlet and outlet. Differential water pressure switch for water flow control. ntifreeze heater. CONDENSING COIL Heat exchanger coil with internally corrugated copper tubes and high efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops. The combination of two factors, special tubes and fins, allow to optimally combine the following aspects: - Maximum capacity relative to the size of the exchanger. - Minimum charge of refrigerant. - Reduction of the air flow required for the heat exchange. Sub-cooling circuit to allow a significant increase in cooling capacity. Frame in galvanized steel. FREE-COOLING COIL Heat exchanger coil with copper tubes and high efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops. The combination of two factors, special tubes and fins, allow to optimally combine the following aspects: - Maximum capacity relative to the size of the exchanger. - Reduction of the air flow required for the heat exchange. Frame in galvanized steel. Motorized valves for free-cooling water circuit control. Temperature sensor on ambient air. IT Cooling REFRIGERNT CIRCUIT Components for each refrigerant circuit: Thermostatic expansion valve up to model 76 P2 C3 D included. Electronic expansion valve from model 98 P2 C4 S included. The valve allows high performance and system efficiency thanks to a timely and accurate response to changes in temperature and pressure. The electronic expansion valve exclude the installation of the electromagnetic valve on liquid line. Sight glass. Liquid receiver. Electromagnetic valve on liquid line. The electromagnetic valve is not installed when the electronic expansion valve is present. Filter dryer on liquid line. Service valves on liquid line and gas discharge. Safety valve on low pressure side. Safety valve on high pressure side. Pressure transducers with indication, control and protection functions, on low and high refrigerant pressure. High pressure safety switch with manual reset. Refrigerant circuit with copper tubing with anticondensate insulation of the suction line. Plastic capillary hoses for pressure sensors connection. R410 refrigerant charge. ELECTRICL PNEL In accordance with EN norms, suitable for outdoor installation, complete with: Main switch with door lock safety. Magnetothermic switch or fuses for each compressor. Magnetothermic switches for fans or water pumps (if scheduled). Contactors for each load. Transformer for auxiliary circuit and microprocessor supply. Panel with machine controls. Power supply: 400/3/50. CONTROL SYSTEM MP.COM microprocessor system with graphic display for control and monitor of operating and alarms status. The system includes: - Voltage free contact for remote general alarm. - Main components hour-meter. - Nonvolatile Flash memory for data storage. - Menu with protection password. - LN connection. FNS SECTION xial fans with sickle-shaped blades, fan guard and optimized for low noise levels. Brushless type synchronous EC motor with integrated electronic commutated system and continuous variation of the rotation speed. The motor rotation control is obtained with the EC system (Electronic Commutation) that manage the motor according to the 0 10V proportional signal coming from the microprocessor control. Maintenance-free bearings IP54 enclosure class. 118 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

119 IT Cooling MXIMO OPTIONL CCESSORIES MXIMO Pumping group (1 pump) Pumping group (2 pumps) Chilled water storage tank LNO kit (noise reduction) ELN kit (extremely noise reduction) Spring antivibration holders (kit) Rubber support (kit) Kit brine (for glycol solution production up to -6 C) Kit brine B (for glycol solution production up to -12 C) 79 - Electrical panel heating system Partial heat recovery Coils protection nets Coils with pre-painted fins Condensing coil in special execution Silencing plenum on condensing air discharge Safety water flow switch Glycol free Compr. power factor capacitor - 0, Soft Starter 83 - Compressor operation indicator Expansion valve energy reserve module mbient temperature sensor 81 - Phases sequence control nalogic flowmeter Power supply analyzer Multimeter kit Clock card RC-Com MBUS/JBUS Serial board LON Serial board BCnet Ethernet - SNMP - TCP/IP Serial board BCnet MS/TP Serial board Serial card for GSM Modem Data Logger Kit modem GSM Plantwatch without modem Remote graphic terminal kit Master plant SEQUENCER RC CLOUD PLTFORM C1 C2 C3 C4 C5 C5H - - available accessory; - not available accessory fiftycoolyears RCGROUP Sp G_ITC_RCW

120 MXIMO IT Cooling TECHNICL DT MXIMO STNDRD OPTIONL LNO KIT 100% LNO KIT 85% ELN KIT MXIMO Cooling capacity (1) Free-Cooling capacity (2) Total water flow rate Total pressure drop kpa Compressors Quantity n. Capacity steps n. xial fans EC n. ir circuits n. Refrigerant Total refrigerant charge (optional excluded) Gas circuits n. Power supply V/Ph/Hz Max unit operating current (FL) Unit starting current (LR) EER (1) / ESEER Sound power level [Lw] (3) verage sound pressure level [LPm] (4) Net weight Hydraulic connections Evaporator IN/OUT - ISO 7/1 R Ø Evaporator IN/OUT - OD (5) Ø mm Partial heat recovery (6) Heating capacity Pumping group 1 pump - 2 poles electric motor 2 pump - 2 poles electric motor Water tank - volume l Cooling capacity (1) Free-Cooling capacity (2) EER (1) / Sound power level [Lw] (3) verage sound pressure level [LPm] (4) Cooling capacity (1) Free-Cooling capacity (2) EER (1) / Sound power level [Lw] (3) verage sound pressure level [LPm] (4) Cooling capacity (1) Free-Cooling capacity (2) EER (1) / Sound power level [Lw] (3) verage sound pressure level [LPm] (4) 21 P1 24 P1 28 P1 30 P1 34 P1 40 P1 50 P1 52 P2 S S S S S S S S C1 C1 C1 C1 C2 C2 C2 C2 22,2 25,0 29,6 32,4 39,0 43,9 54,0 56,0 7,9 9,3 11,7 13,1 13,4 16,1 21,6 22,5 19,8 20,6 24,9 25,7 33,3 37,5 44,7 45,1 4,1 4,6 5,5 6,0 7,2 8,1 10,0 10, scroll scroll scroll scroll scroll scroll scroll scroll R410 R410 R410 R410 R410 R410 R410 R410 11,3 11,3 11,3 11,5 13,7 13,7 15,0 15, /3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 18,4 23,6 24,8 27,9 35,7 38,9 45,4 49,6 96,5 112,5 119,6 119,6 143,0 177,0 228,2 143,2 2,81 2,69 2,52 2,47 2,92 2,72 2,50 2,49 3,31 3,20 3,18 3,07 3,52 3,22 3,00 3,13 80,8 81,2 82,6 81,8 83,6 86,6 89,8 87,2 64,2 64,6 66,0 65,2 66,4 69,4 72,5 70, /2" 1 1/2" 1 1/2" 1 1/2" 2" 2" 2" 2" ,7 8,6 10,2 11,1 13,4 15,1 18,6 19,3 1,1 1,1 1,1 1,1 1,5 1,5 1,5 1, ,2 25,0 29,6 32,4 39,0 43,9 54,0 56,0 8,0 9,4 11,7 13,1 13,4 16,3 21,6 22,5 19,8 20,6 24,9 25,7 33,3 37,5 44,7 45, ,79 2,67 2,52 2,47 2,91 2,70 2,50 2,49 80,3 80,4 82,1 81,1 83,0 86,2 88,4 87,0 63,7 63,8 65,5 64,5 65,8 69,0 71,2 69,8 21,7 24,3 28,8 31,3 37,9 42,8 52,6 54,2 8,0 9,5 11,9 13,3 13,6 16,3 21,7 22,9 19,6 20,4 24,7 25,4 33,0 37,2 44,4 44, ,70 2,55 2,42 2,36 2,78 2,62 2,42 2,37 76,7 76,9 78,5 77,6 79,4 82,5 85,2 83,2 60,1 60,3 61,9 61,0 62,2 65,3 68,0 66,0 20,9 23,3 27,6 29,8 36,4 41,1 50,5 51,7 8,3 9,9 12,2 13,8 14,1 16,7 22,4 23,6 19,3 20,1 24,4 25,0 32,6 36,8 43,9 44, ,52 2,36 2,26 2,16 2,58 2,46 2,25 2,19 72,8 73,3 74,6 73,9 75,7 78,5 82,3 79,0 56,2 56,8 58,0 57,3 58,5 61,3 65,1 61,8 1. Referred to glycol solution temperature 15/10 C; 20% Ethylene glycol solution; air temperature to the condenser 35 C. Fouling factor of the exchangers 0,043 m² K/. 2. Referred to glycol solution inlet temperature 15 C; 20% Ethylene glycol solution; ambient temperature 3 C. Fouling factor of the exchangers 0,043 m² K/. 3. Sound power level [Lw] according to ISO EN verage sound pressure level [LPm] 1m far according to ISO EN Hydraulic connection with grooved end complete with flexible joint and adapter pipe for solder connection. 6. Referred to glycol solution temperature 15/10 C; 20% Ethylene glycol solution; air temperature to the condenser 35 C. Water temperature heat recovery 40/45 C 0% glycol solution; Fouling factor of the exchangers 0,043 m² K/. 120 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

121 IT Cooling MXIMO TECHNICL DT MXIMO STNDRD OPTIONL LNO KIT 100% LNO KIT 85% ELN KIT MXIMO Cooling capacity (1) Free-Cooling capacity (2) Total water flow rate Total pressure drop kpa Compressors Quantity n. Capacity steps n. xial fans EC n. ir circuits n. Refrigerant Total refrigerant charge (optional excluded) Gas circuits n. Power supply V/Ph/Hz Max unit operating current (FL) Unit starting current (LR) EER (1) / ESEER Sound power level [Lw] (3) verage sound pressure level [LPm] (4) Net weight Hydraulic connections Evaporator IN/OUT - ISO 7/1 R Ø Evaporator IN/OUT - OD (5) Ø mm Partial heat recovery (6) Heating capacity Pumping group 1 pump - 2 poles electric motor 2 pump - 2 poles electric motor Water tank - volume l Cooling capacity (1) Free-Cooling capacity (2) EER (1) / Sound power level [Lw] (3) verage sound pressure level [LPm] (4) Cooling capacity (1) Free-Cooling capacity (2) EER (1) / Sound power level [Lw] (3) verage sound pressure level [LPm] (4) Cooling capacity (1) Free-Cooling capacity (2) EER (1) / Sound power level [Lw] (3) verage sound pressure level [LPm] (4) 52 P2 58 P2 58 P2 62 P1 65 P2 65 P2 76 P2 76 P2 D S D S S D S D C2 C3 C3 C3 C3 C3 C3 C3 55,8 65,1 65,3 69,3 73,1 72,8 83,4 83,1 22,6 23,6 23,9 26,1 27,2 27,0 33,2 32,8 45,1 56,7 56,7 59,2 61,6 61,6 68,1 68,0 10,3 12,0 12,0 12,8 13,5 13,4 15,4 15, scroll scroll scroll scroll scroll scroll scroll scroll R410 R410 R410 R410 R410 R410 R410 R410 16,0 21,7 19,3 18,9 22,1 19,6 28,6 25, /3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 49,6 57,2 57,2 55,7 69,8 69,8 76,4 76,4 143,2 147,5 147,5 276,5 175,5 175,5 212,8 212,8 2,47 2,76 2,73 2,66 2,69 2,70 2,51 2,53 3,55 3,44 3,80 3,16 3,34 3,68 3,09 3,47 87,2 88,2 88,2 93,0 88,1 88,1 87,3 87,3 70,0 70,3 70,3 75,1 70,2 70,2 69,4 69, " ,1 76,1 76,1 76,1 76,1 76,1 76,1 19,2 22,4 22,5 23,8 25,1 25,0 28,7 28,6 1,5 3,0 3,0 3,0 3,0 3,0 3,0 3,0-3,0 3,0 3,0 3,0 3,0 3,0 3, ,8 65,1 65,3 69,3 73,1 72,8 83,4 83,1 22,6 23,8 24,1 26,2 27,4 27,2 33,2 32,8 45,1 56,7 56,7 59,2 61,6 61,6 68,1 68, ,47 2,74 2,71 2,65 2,67 2,68 2,51 2,53 87,0 87,9 87,9 91,5 87,9 87,9 87,0 87,0 69,8 70,0 70,0 73,6 70,0 70,0 69,2 69,2 54,0 63,2 63,4 67,4 71,0 70,7 81,0 80,6 22,8 24,1 24,5 26,3 27,5 27,3 33,3 32,9 44,7 56,2 56,3 58,8 61,1 61,1 67,5 67, ,37 2,62 2,59 2,56 2,58 2,59 2,43 2,45 83,2 84,2 84,2 88,4 84,1 84,1 83,3 83,3 66,0 66,3 66,3 70,5 66,2 66,2 65,4 65,4 51,5 60,6 60,8 64,8 67,9 67,6 77,5 77,2 23,6 25,0 25,4 27,2 28,3 28,3 34,1 33,9 44,2 55,5 55,6 58,1 60,4 60,3 66,8 66, ,18 2,42 2,39 2,38 2,40 2,39 2,27 2,28 79,0 79,9 79,9 85,6 79,8 79,8 79,1 79,1 61,8 62,0 62,0 67,7 61,9 61,9 61,2 61,2 1. Referred to glycol solution temperature 15/10 C; 20% Ethylene glycol solution; air temperature to the condenser 35 C. Fouling factor of the exchangers 0,043 m² K/. 2. Referred to glycol solution inlet temperature 15 C; 20% Ethylene glycol solution; ambient temperature 3 C. Fouling factor of the exchangers 0,043 m² K/. 3. Sound power level [Lw] according to ISO EN verage sound pressure level [LPm] 1m far according to ISO EN Hydraulic connection with grooved end complete with flexible joint and adapter pipe for solder connection. 6. Referred to glycol solution temperature 15/10 C; 20% Ethylene glycol solution; air temperature to the condenser 35 C. Water temperature heat recovery 40/45 C 0% glycol solution; Fouling factor of the exchangers 0,043 m² K/ fiftycoolyears RCGROUP Sp G_ITC_RCW

122 MXIMO IT Cooling TECHNICL DT MXIMO STNDRD OPTIONL LNO KIT 100% LNO KIT 85% ELN KIT MXIMO Cooling capacity (1) Free-Cooling capacity (2) Total water flow rate Total pressure drop kpa Compressors Quantity n. Capacity steps n. xial fans EC n. ir circuits n. Refrigerant Total refrigerant charge (optional excluded) Gas circuits n. Power supply V/Ph/Hz Max unit operating current (FL) Unit starting current (LR) EER (1) / ESEER Sound power level [Lw] (3) verage sound pressure level [LPm] (4) Net weight Hydraulic connections Evaporator IN/OUT - ISO 7/1 R Ø Evaporator IN/OUT - OD (5) Ø mm Partial heat recovery (6) Heating capacity Pumping group 1 pump - 2 poles electric motor 2 pump - 2 poles electric motor Water tank - volume l Cooling capacity (1) Free-Cooling capacity (2) EER (1) / Sound power level [Lw] (3) verage sound pressure level [LPm] (4) Cooling capacity (1) Free-Cooling capacity (2) EER (1) / Sound power level [Lw] (3) verage sound pressure level [LPm] (4) Cooling capacity (1) Free-Cooling capacity (2) EER (1) / Sound power level [Lw] (3) verage sound pressure level [LPm] (4) 98 P2 98 P2 124 P2 124 P2 158 P2 158 P2 180 P2 180 P2 S D S D S D S D C4 C4 C4 C4 C4 C4 C5 C5 109,0 108,0 133,0 131,0 171,0 173,0 196,0 198,0 41,1 40,1 54,1 52,2 71,0 72,7 76,6 77,6 88,0 87,7 103,0 103,0 118,0 118,0 140,0 141,0 20,0 19,8 24,6 24,2 31,5 31,9 36,2 36, scroll scroll scroll scroll scroll scroll scroll scroll R410 R410 R410 R410 R410 R410 R410 R410 33,9 31,3 38,6 42,1 50,9 42,9 73,7 65, /3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 90,7 90,7 113,8 113,8 149,3 149,3 169,8 169,8 271,4 271,4 331,9 331,9 386,8 386,8 473,7 473,7 2,65 2,69 2,46 2,51 2,41 2,38 2,56 2,55 3,25 3,64 3,01 3,41 2,96 3,30 3,12 3,51 87,0 87,0 90,9 90,9 93,0 93,0 93,3 93,3 68,4 68,4 72,3 72,3 74,4 74,4 74,1 74, ,9 88,9 88,9 88,9 88,9 88,9 88,9 88,9 37,4 37,0 45,8 45,1 58,8 59,5 67,6 67,9 3,0 3,0 3,0 3,0 3,0 3,0 5,5 5,5 4,0 4,0 4,0 4,0 4,0 4,0 7,5 7, ,0 108,0 133,0 131,0 171,0 173,0 196,0 198,0 41,1 40,1 54,1 52,2 71,0 72,7 76,6 77,6 88,0 87,7 103,0 103,0 118,0 118,0 140,0 141, ,65 2,69 2,46 2,51 2,41 2,38 2,56 2,55 86,2 86,2 90,6 90,6 92,8 92,8 93,2 93,2 67,6 67,6 72,0 72,0 74,2 74,2 73,9 73,9 106,0 105,0 129,0 127,0 165,0 167,0 190,0 191,0 41,4 40,5 54,0 52,0 70,8 72,6 76,9 78,0 87,2 86,9 103,0 102,0 117,0 117,0 139,0 139, ,56 2,59 2,39 2,44 2,33 2,30 2,47 2,45 82,7 82,7 86,8 86,8 89,0 89,0 89,4 89,4 64,1 64,1 68,2 68,2 70,4 70,4 70,1 70,1 102,0 101,0 124,0 122,0 157,0 159,0 181,0 182,0 42,9 41,9 55,4 53,3 73,0 75,0 80,1 80,9 86,1 85,7 101,0 101,0 115,0 116,0 136,0 136, ,38 2,41 2,24 2,29 2,15 2,12 2,26 2,25 79,2 79,2 82,7 82,7 84,6 84,6 85,0 85,0 60,6 60,6 64,1 64,1 66,0 66,0 65,7 65,7 1. Referred to glycol solution temperature 15/10 C; 20% Ethylene glycol solution; air temperature to the condenser 35 C. Fouling factor of the exchangers 0,043 m² K/. 2. Referred to glycol solution inlet temperature 15 C; 20% Ethylene glycol solution; ambient temperature 3 C. Fouling factor of the exchangers 0,043 m² K/. 3. Sound power level [Lw] according to ISO EN verage sound pressure level [LPm] 1m far according to ISO EN Hydraulic connection with grooved end complete with flexible joint and adapter pipe for solder connection. 6. Referred to glycol solution temperature 15/10 C; 20% Ethylene glycol solution; air temperature to the condenser 35 C. Water temperature heat recovery 40/45 C 0% glycol solution; Fouling factor of the exchangers 0,043 m² K/. 122 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

123 IT Cooling MXIMO TECHNICL DT MXIMO STNDRD OPTIONL LNO KIT 100% LNO KIT 85% ELN KIT MXIMO Cooling capacity (1) Free-Cooling capacity (2) Total water flow rate Total pressure drop kpa Compressors Quantity n. Capacity steps n. xial fans EC n. ir circuits n. Refrigerant Total refrigerant charge (optional excluded) Gas circuits n. Power supply V/Ph/Hz Max unit operating current (FL) Unit starting current (LR) EER (1) / ESEER Sound power level [Lw] (3) verage sound pressure level [LPm] (4) Net weight Hydraulic connections Evaporator IN/OUT - ISO 7/1 R Ø Evaporator IN/OUT - OD (5) Ø mm Partial heat recovery (6) Heating capacity Pumping group 1 pump - 2 poles electric motor 2 pump - 2 poles electric motor Water tank - volume l Cooling capacity (1) Free-Cooling capacity (2) EER (1) / Sound power level [Lw] (3) verage sound pressure level [LPm] (4) Cooling capacity (1) Free-Cooling capacity (2) EER (1) / Sound power level [Lw] (3) verage sound pressure level [LPm] (4) Cooling capacity (1) Free-Cooling capacity (2) EER (1) / Sound power level [Lw] (3) verage sound pressure level [LPm] (4) 197 P2 197 P2 230 P3 240 P4 270 P4 S D S D D C5 C5 C5 C5H C5H 215,0 212,0 242,0 270,0 299,0 90,3 87,2 109,5 107,6 126,2 151,0 150,0 159,0 171,0 197,0 39,7 39,1 44,7 49,8 54, scroll scroll scroll scroll scroll R410 R410 R410 R410 R410 83,1 102,2 83,7 127,0 126, /3/50 400/3/50 400/3/50 400/3/50 400/3/50 187,2 187,2 221,0 218,7 254,2 490,3 490,3 455,1 431,8 486,7 2,38 2,43 2,21 2,51 2,37 2,96 3,43 3,52 3,66 3,64 93,7 93,7 94,7 93,4 93,4 74,4 74,4 75,4 74,1 74, ,9 88,9 88,9 88,9 88,9 73,9 72,9 83,2 92,8 103,0 5,5 5,5 5,5 5,5 5,5 7,5 7,5 7,5 7,5 7, ,0 212,0 242,0 270,0 299,0 90,3 87,2 109,5 107,6 126,2 151,0 150,0 159,0 171,0 197, ,38 2,43 2,21 2,51 2,37 93,6 93,6 94,5 93,0 93,0 74,3 74,3 75,2 73,8 73,8 207,0 204,0 232,0 261,0 287,0 92,0 88,3 112,1 108,3 128,7 150,0 149,0 157,0 169,0 195, ,25 2,31 2,07 2,41 2,23 89,8 89,8 90,7 89,3 89,3 70,5 70,5 71,4 70,0 70,0 196,0 193,0 217,0 248,0 270,0 96,1 92,8 116,0 111,7 134,3 148,0 147,0 155,0 168,0 193, ,04 2,08 1,87 2,22 2,01 85,4 85,4 86,3 85,2 85,2 66,1 66,1 67,1 65,9 65,9 1. Referred to glycol solution temperature 15/10 C; 20% Ethylene glycol solution; ambient temperature 35 C. Fouling factor of the exchangers 0,043 m² K/. 2. Referred to glycol solution inlet temperature 15 C; 20% Ethylene glycol solution; ambient temperature 3 C. Fouling factor of the exchangers 0,043 m² K/. 3. Sound power level [Lw] according to ISO EN verage sound pressure level [LPm] 1m far according to ISO EN Hydraulic connection with grooved end complete with flexible joint and adapter pipe for solder connection. 6. Referred to chiller water temperature 12/7 C; 35 C ambient temperature and hot water temperature 40/45 C fiftycoolyears RCGROUP Sp G_ITC_RCW

124 MXIMO IT Cooling DIMENSIONS (mm) C a b c C C C C C C5H c b a 124 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

125 MXIMO PF MXIMO PF: Packaged air cooled liquid chillers with free-cooling system for indoor installation, equipped with scroll compressors and plug fan Cooling Capacity: Free-Cooling Capacity: FREECOOLING MXIMO PF rcgroupairconditioning R410 FREE COOLING PLTE E C MIN FETURES ir cooled liquid chiller with free-cooling system. 29 models available, for a wide selection opportunity. verage step of 12,5. EER up to 2,79. ESEER up to 3,40. Scroll compressors. R410 Refrigerant charge. Single or double refrigerant circuit. Plate type heat exchangers. EC Plug fan. Single air circuit. Electronic expansion valve. Suitable for outdoor installation. MIN BENEFITS Units equipped with two scroll compressors for refrigerant circuit to reach a high efficiency. Units with single and double refrigerant circuits. Indirect free cooling system. High ESEER. EC Plug fan for a high efficiency. vailability of kit for the reduction of the noise. vailability of pumping groups. vailability of partial heat recovery system. Easily of maintenance. Components dedicated to the safety of the unity. Eurovent Certification. INDIRECT FREE COOLING SYSTEM Complete cooling of the chilled water of the existing cooling system with the outside air. The energy saving will be higher the longer the outside temperature remains below the required temperature for cooling. INDOOR INSTLLTION The machines are designed for indoor installation and ducting for air suction and discharge. For outdoor installation the use of the dedicated optional kit is mandatory. The machine must be installed under a cover or anyway protected against atmospherics agent. WORKING LIMITS IN COOLING MODE Chilled water outlet temperature: 4 15 C mbient temperature: C WORKING LIMITS IN FREE-COOLING MODE Minimum chilled water outlet temperature: -15 C Minimum ambient temperature: -20 C fiftycoolyears fiftycoolyears RCGROUP Sp G_ITC_RCW

126 MXIMO PF MIN COMPONENTS FRMEWORK Base, self supporting frame and panelling in steel plate with protective surfaces treatment in compliance with UNI ISO 9227/STMB117 and ISO 7253, and painted with epoxy powders. Colour: RL 9002 COMPRESSORS Orbiting spiral (SCROLL) hermetic compressors with spiral profile optimized for R410 refrigerant. ON / OFF capacity control (0 / 100% each compressor). 2-pole 3-phase electric motor with direct on line starting. Phase sequence electronic relay. Crankcase heater. Electric motor thermal protection via internal winding temperature sensors. Rubber supports. EVPORTOR Copper brazed plate type with cover plates, plates and connections in ISI 316 stainless steel: - With single refrigerant circuit for S version machines. - With double refrigerant circuit for D version machines. nticondensate insulation made of polyurethane. Temperature sensors on water inlet and outlet. Differential water pressure switch for water flow control. ntifreeze heater. CONDENSING COIL Heat exchanger coil with internally corrugated copper tubes and high efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops. The combination of two factors, special tubes and fins, allow to optimally combine the following aspects: - Maximum capacity relative to the size of the exchanger. - Minimum charge of refrigerant. - Reduction of the air flow required for the heat exchange. Sub-cooling circuit to allow a significant increase in cooling capacity. Frame in galvanized steel. FREE-COOLING COIL Heat exchanger coil with copper tubes and high efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops. The combination of two factors, special tubes and fins, allow to optimally combine the following aspects: - Maximum capacity relative to the size of the exchanger. - Reduction of the air flow required for the heat exchange. Frame in galvanized steel. Motorized valves for free-cooling water circuit control. Temperature sensor on ambient air. IT Cooling REFRIGERNT CIRCUIT Components for each refrigerant circuit: Thermostatic expansion valve up to model 85 P2 C3 D included. Electronic expansion valve from model 107 P2 C3 D included. The valve allows high performance and system efficiency thanks to a timely and accurate response to changes in temperature and pressure. The electronic expansion valve exclude the installation of the electromagnetic valve on liquid line. Sight glass. Electromagnetic valve on liquid line. The electromagnetic valve is not installed when the electronic expansion valve is present. Filter dryer on liquid line. Service valves on liquid line and gas discharge. Safety valve on low pressure side. Pressure transducers with indication, control and protection functions, on low and high refrigerant pressure. High pressure safety switch with manual reset. Refrigerant circuit with copper tubing with anticondensate insulation of the suction line. Plastic capillary hoses for pressure sensors connection. R410 refrigerant charge. ELECTRICL PNEL In accordance with EN norms complete with: Main switch with door lock safety. Magnetothermic switch or fuses for each compressor. Magnetothermic switches for fans or water pumps (if scheduled). Contactors for each load. Transformer for auxiliary circuit and microprocessor supply. Panel with machine controls. Power supply: 400/3/50. CONTROL SYSTEM MP.COM microprocessor system with graphic display for control and monitor of operating and alarms status. The system includes: - Voltage free contact for remote general alarm. - Main components hour-meter. - Nonvolatile Flash memory for data storage. - Menu with protection password. - LN connection. FNS SECTION Centrifugal fans with backward curved blades, single suction and without scroll housings (Plug-fan). Brushless type synchronous EC motor with integrated electronic commutated system and continuous variation of the rotation speed. The motor rotation control is obtained with the EC system (Electronic Commutation) that manage the motor according to the 0 10V proportional signal coming from the microprocessor control. Maintenance-free bearings IP54 enclosure class. 126 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

127 IT Cooling MXIMO PF OPTIONL CCESSORIES MXIMO PF Pumping group (1 pump) Pumping group (2 pumps) Chilled water storage tank LNO kit (noise reduction) Spring antivibration holders (kit) Rubber support (kit) Kit brine (for glycol solution production up to -6 C) Kit brine B (for glycol solution production up to -12 C) 79 - Electrical panel heating system Kit for outdoor installation Partial heat recovery Coils protection nets Coils with pre-painted fins Condensing coil in special execution Discharge air plenum with sound attenuators Safety water flow switch Glycol free Compr. power factor capacitor - 0, Soft Starter 83 - Compressor operation indicator Expansion valve energy reserve module mbient temperature sensor 81 - Phases sequence control nalogic flowmeter Power supply analyzer Multimeter kit Clock card RC-Com MBUS/JBUS Serial board LON Serial board BCnet Ethernet - SNMP - TCP/IP Serial board BCnet MS/TP Serial board Serial card for GSM Modem Data Logger Kit modem GSM Plantwatch without modem Remote graphic terminal kit Master plant SEQUENCER RC CLOUD PLTFORM C1 C2 C3 C4 C5 - - available accessory; - not available accessory fiftycoolyears RCGROUP Sp G_ITC_RCW

128 MXIMO PF IT Cooling TECHNICL DT MXIMO PF STNDRD OPTIONL LNO KIT 100% LNO KIT 85% LNO KIT 70% MXIMO PF Cooling capacity (1) Free-Cooling capacity (2) Total water flow rate Total pressure drop kpa Compressors Quantity n. Capacity steps n. Centrifugal fans EC n. External static pressure Pa ir circuits n. Refrigerant Total refrigerant charge (optional excluded) Gas circuits n. Power supply V/Ph/Hz Max unit operating current (FL) Unit starting current (LR) EER (1) / ESEER Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) Net weight Hydraulic connections Evaporator IN/OUT - ISO 7/1 R Ø Evaporator IN/OUT - OD (5) Ø mm Partial heat recovery (6) Heating capacity Pumping group 1 pump - 2 poles electric motor 2 pump - 2 poles electric motor Water tank - volume l Cooling capacity (1) Free-Cooling capacity (2) External static pressure Pa EER (1) / Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) Cooling capacity (1) Free-Cooling capacity (2) External static pressure Pa EER (1) / Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) Cooling capacity (1) Free-Cooling capacity (2) External static pressure Pa EER (1) / Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) 22 P1 24 P1 28 P1 32 P1 36 P1 42 P1 53 P1 67 P1 S S S S S S S S C1 C1 C1 C1 C1 C1 C2 C2 21,4 23,9 27,9 31,6 35,2 39,6 51,4 64,4 7,7 9,0 10,9 11,8 14,2 17,2 20,8 26,0 18,1 19,5 22,9 26,0 28,2 29,9 42,3 52,1 4,0 4,4 5,2 5,8 6,5 7,3 9,5 11, scroll scroll scroll scroll scroll scroll scroll scroll R410 R410 R410 R410 R410 R410 R410 R410 11,3 11,3 11,3 11,5 11,6 11, , /3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 21,3 26,6 27,6 31,4 37,7 40,8 51,0 59,7 99,3 115,3 122,3 122,9 144,9 178,9 233,6 280,4 2,79 2,66 2,55 2,68 2,48 2,30 2,47 2,48 3,17 3,03 2,95 3,14 2,86 2,60 2,84 2,97 87,3 88,9 93,0 92,1 94,5 95,5 95,0 97,2 70,7 72,3 76,4 75,5 77,9 78,9 77,8 80, /2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 2" 2" ,4 8,2 9,6 10,9 12,1 13,6 17,7 22,2 1,1 1,1 1,1 1,1 1,1 1,1 1,5 1, ,4 23,9 27,9 31,6 35,2 39,6 51,4 64,4 7,7 9,0 10,9 11,8 14,2 17,2 20,8 26,0 18,1 19,5 22,9 26,0 28,2 29,9 42,3 52, ,79 2,66 2,55 2,68 2,48 2,30 2,47 2,48 87,1 88,7 92,8 92,1 94,1 96,0 94,6 96,4 70,5 72,1 76,2 75,5 77,5 79,4 77,4 79,2 20,8 23,2 27,0 30,6 34,0 38,2 50,0 62,6 7,7 9,0 10,8 11,9 13,9 16,9 20,7 25,9 17,9 19,4 22,7 25,7 28,0 29,6 41,9 51, ,69 2,57 2,49 2,58 2,45 2,26 2,42 2,42 83,6 85,2 89,3 88,2 90,6 92,5 91,2 93,0 67,0 68,6 72,7 71,6 74,0 75,9 74,0 75,8 19,9 22,1 25,8 29,2 32,5 36,3 47,9 59,9 8,0 9,4 11,1 12,3 14,0 17,2 21,2 26,5 17,6 19,1 22,3 25,3 27,6 29,2 41,5 51, ,49 2,36 2,33 2,37 2,32 2,11 2,26 2,26 80,4 82,0 86,1 83,6 87,4 89,3 88,2 90,1 63,8 65,4 69,5 67,1 70,8 72,7 71,0 72,9 1. Referred to glycol solution temperature 15/10 C; 20% Ethylene glycol solution; air temperature to the condenser 35 C. Fouling factor of the exchangers 0,043 m² K/. 2. Referred to glycol solution inlet temperature 15 C; 20% Ethylene glycol solution; ambient temperature 3 C. Fouling factor of the exchangers 0,043 m² K/. 3. Sound power level [Lw] according to ISO EN verage sound pressure level [LPm] 1m far according to ISO EN Hydraulic connection with grooved end complete with flexible joint and adapter pipe for solder connection. 6. Referred to glycol solution temperature 15/10 C; 20% Ethylene glycol solution; air temperature to the condenser 35 C. Water temperature heat recovery 40/45 C 0% glycol solution; Fouling factor of the exchangers 0,043 m² K/. 128 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

129 IT Cooling MXIMO PF TECHNICL DT MXIMO PF STNDRD OPTIONL LNO KIT 100% LNO KIT 85% LNO KIT 70% MXIMO PF Cooling capacity (1) Free-Cooling capacity (2) Total water flow rate Total pressure drop kpa Compressors Quantity n. Capacity steps n. Centrifugal fans EC n. External static pressure Pa ir circuits n. Refrigerant Total refrigerant charge (optional excluded) Gas circuits n. Power supply V/Ph/Hz Max unit operating current (FL) Unit starting current (LR) EER (1) / ESEER Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) Net weight Hydraulic connections Evaporator IN/OUT - ISO 7/1 R Ø Evaporator IN/OUT - OD (5) Ø mm Partial heat recovery (6) Heating capacity Pumping group 1 pump - 2 poles electric motor 2 pump - 2 poles electric motor Water tank - volume l Cooling capacity (1) Free-Cooling capacity (2) External static pressure Pa EER (1) / Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) Cooling capacity (1) Free-Cooling capacity (2) External static pressure Pa EER (1) / Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) Cooling capacity (1) Free-Cooling capacity (2) External static pressure Pa EER (1) / Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) 55 P2 55 P2 62 P2 62 P2 71 P2 71 P2 85 P2 85 P2 S D S D S D S D C2 C2 C2 C2 C2 C2 C3 C3 54,1 54,2 60,7 60,9 68,4 68,3 80,5 80,1 22,1 21,9 24,3 24,1 28,9 28,6 31,3 31,2 45,7 45,7 50,6 50,6 55,6 55,5 67,1 67,0 10,0 10,0 11,2 11,2 12,6 12,6 14,9 14, scroll scroll scroll scroll scroll scroll scroll scroll R410 R410 R410 R410 R410 R410 R410 R410 18, , ,7 16,2 28,7 25, /3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 56,5 56,5 61,3 61,3 73,9 73,9 86,8 86,8 149,8 149,8 151,4 151,4 179,4 179,4 222,7 222,7 2,45 2,48 2,50 2,53 2,37 2,39 2,57 2,57 3,28 3,01 3,33 2,84 2,83 3,09 3,01 3,25 93,6 93,6 87,5 87,5 89,8 89,8 94,4 94,4 76,4 76,4 70,3 70,3 72,6 72,6 76,5 76, " 2" 2" 2" 2" 2" ,1 76,1 18,6 18,6 20,9 21,0 23,5 23,5 27,7 27,6 1,5 1,5 1,5 1,5 1,5 1,5 3,0 3, ,0 3, ,1 54,2 60,7 60,9 68,4 68,3 80,5 80,1 22,1 21,9 24,3 24,1 28,9 28,6 31,3 31,2 45,7 45,7 50,6 50,6 55,6 55,5 67,1 67, ,45 2,48 2,50 2,53 2,37 2,39 2,57 2,57 93,1 93,1 86,5 86,5 89,0 89,0 93,7 93,7 75,9 75,9 69,3 69,3 71,8 71,8 75,8 75,8 52,5 52,6 58,9 59,0 66,3 66,2 78,2 77,8 21,9 21,6 23,9 23,9 28,0 27,7 31,0 30,9 45,3 45,4 50,2 50,2 55,1 55,1 66,5 66, ,40 2,43 2,46 2,47 2,37 2,39 2,52 2,52 89,6 89,6 83,1 83,1 85,5 85,5 90,3 90,3 72,4 72,4 65,9 65,9 68,3 68,3 72,4 72,4 50,2 50,3 56,3 56,4 63,3 63,2 74,9 74,5 22,4 22,2 24,4 24,4 28,3 28,0 31,6 31,6 44,8 44,8 49,6 49,6 54,4 54,4 65,8 65, ,24 2,27 2,31 2,31 2,24 2,26 2,37 2,36 86,4 86,4 80,2 80,2 82,5 82,5 87,2 87,2 69,2 69,2 63,0 63,0 65,3 65,3 69,3 69,3 1. Referred to glycol solution temperature 15/10 C; 20% Ethylene glycol solution; air temperature to the condenser 35 C. Fouling factor of the exchangers 0,043 m² K/. 2. Referred to glycol solution inlet temperature 15 C; 20% Ethylene glycol solution; ambient temperature 3 C. Fouling factor of the exchangers 0,043 m² K/. 3. Sound power level [Lw] according to ISO EN verage sound pressure level [LPm] 1m far according to ISO EN Hydraulic connection with grooved end complete with flexible joint and adapter pipe for solder connection. 6. Referred to glycol solution temperature 15/10 C; 20% Ethylene glycol solution; air temperature to the condenser 35 C. Water temperature heat recovery 40/45 C 0% glycol solution; Fouling factor of the exchangers 0,043 m² K/ fiftycoolyears RCGROUP Sp G_ITC_RCW

130 MXIMO PF IT Cooling TECHNICL DT MXIMO PF STNDRD OPTIONL LNO KIT 100% LNO KIT 85% LNO KIT 70% MXIMO PF Cooling capacity (1) Free-Cooling capacity (2) Total water flow rate Total pressure drop kpa Compressors Quantity n. Capacity steps n. Centrifugal fans EC n. External static pressure Pa ir circuits n. Refrigerant Total refrigerant charge (optional excluded) Gas circuits n. Power supply V/Ph/Hz Max unit operating current (FL) Unit starting current (LR) EER (1) / ESEER Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) Net weight Hydraulic connections Evaporator IN/OUT - ISO 7/1 R Ø Evaporator IN/OUT - OD (5) Ø mm Partial heat recovery (6) Heating capacity Pumping group 1 pump - 2 poles electric motor 2 pump - 2 poles electric motor Water tank - volume l Cooling capacity (1) Free-Cooling capacity (2) External static pressure Pa EER (1) / Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) Cooling capacity (1) Free-Cooling capacity (2) External static pressure Pa EER (1) / Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) Cooling capacity (1) Free-Cooling capacity (2) External static pressure Pa EER (1) / Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) 107 P2 107 P2 135 P2 135 P2 170 P2 170 P2 195 P2 195 P2 S D S D S D S D C3 C3 C4 C4 C4 C4 C4 C4 103,0 102,0 128,0 126,0 166,0 164,0 182,0 185,0 42,7 42,5 50,0 50,0 67,8 67,8 70,0 80,4 81,1 80,9 99,5 99,0 124,0 123,0 127,0 127,0 19,1 18,9 23,5 23,2 30,6 30,2 33,6 34, scroll scroll scroll scroll scroll scroll scroll scroll R410 R410 R410 R410 R410 R410 R410 R ,3 35,1 38,6 50,9 42,6 51, /3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 99,4 99,4 119,5 119,5 155,0 155,0 172,4 172,4 279,7 279,7 337,3 337,3 392,2 392,2 456,2 456,2 2,41 2,40 2,56 2,52 2,45 2,42 2,60 2,30 2,82 3,08 2,96 3,40 2,84 3,14 2,72 3,37 99,2 99,2 92,7 92,7 96,2 96,2 96,2 96,2 81,3 81,3 74,1 74,1 77,6 77,6 77,6 77, ,1 76,1 88,9 88,9 88,9 88,9 88,9 88,9 35,6 35,2 43,9 43,2 57,2 56,3 62,6 63,7 3,0 3,0 3,0 3,0 3,0 3,0 3,0 3,0 3,0 3,0 4,0 4,0 4,0 4,0 4,0 4, ,0 102,0 128,0 126,0 166,0 164,0 182,0 185,0 42,7 42,5 50,0 50,0 67,8 67,8 70,0 80,4 81,1 80,9 99,5 99,0 124,0 123,0 127,0 127, ,41 2,40 2,56 2,52 2,45 2,42 2,60 2,30 98,5 98,5 90,2 90,2 95,0 95,0 95,7 95,7 80,6 80,6 71,6 71,6 76,4 76,4 77,1 77,1 101,0 99,4 124,0 122,0 161,0 159,0 176,0 179,0 41,7 41,6 50,0 49,8 66,3 66,0 68,2 79,2 80,6 80,3 98,6 98,1 123,0 122,0 126,0 126, ,42 2,39 2,48 2,45 2,43 2,41 2,58 2,26 95,1 95,1 87,8 87,8 91,9 91,9 92,6 92,6 77,2 77,2 69,2 69,2 73,3 73,3 74,0 74,0 96,5 95,5 118,0 117,0 155,0 153,0 167,0 170,0 42,3 42,1 51,3 51,1 66,8 66,5 69,0 81,0 79,7 79,5 97,3 96,8 121,0 121,0 124,0 125, ,28 2,27 2,30 2,29 2,32 2,30 2,42 2,10 92,0 92,0 86,9 86,9 89,7 89,7 90,3 90,3 74,1 74,1 68,3 68,3 71,1 71,1 71,7 71,7 1. Referred to glycol solution temperature 15/10 C; 20% Ethylene glycol solution; air temperature to the condenser 35 C. Fouling factor of the exchangers 0,043 m² K/. 2. Referred to glycol solution inlet temperature 15 C; 20% Ethylene glycol solution; ambient temperature 3 C. Fouling factor of the exchangers 0,043 m² K/. 3. Sound power level [Lw] according to ISO EN verage sound pressure level [LPm] 1m far according to ISO EN Hydraulic connection with grooved end complete with flexible joint and adapter pipe for solder connection. 6. Referred to glycol solution temperature 15/10 C; 20% Ethylene glycol solution; air temperature to the condenser 35 C. Water temperature heat recovery 40/45 C 0% glycol solution; Fouling factor of the exchangers 0,043 m² K/. 130 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

131 IT Cooling MXIMO PF TECHNICL DT MXIMO PF STNDRD OPTIONL LNO KIT 100% LNO KIT 85% LNO KIT 70% MXIMO PF Cooling capacity (1) Free-Cooling capacity (2) Total water flow rate Total pressure drop kpa Compressors Quantity n. Capacity steps n. Centrifugal fans EC n. External static pressure Pa ir circuits n. Refrigerant Total refrigerant charge (optional excluded) Gas circuits n. Power supply V/Ph/Hz Max unit operating current (FL) Unit starting current (LR) EER (1) / ESEER Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) Net weight Hydraulic connections Evaporator IN/OUT - ISO 7/1 R Ø Evaporator IN/OUT - OD (5) Ø mm Partial heat recovery (6) Heating capacity Pumping group 1 pump - 2 poles electric motor 2 pump - 2 poles electric motor Water tank - volume l Cooling capacity (1) Free-Cooling capacity (2) External static pressure Pa EER (1) / Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) Cooling capacity (1) Free-Cooling capacity (2) External static pressure Pa EER (1) / Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) Cooling capacity (1) Free-Cooling capacity (2) External static pressure Pa EER (1) / Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) 220 P2 220 P2 250 P3 265 P4 290 P4 S D S D D C5 C5 C5 C5 C5 210,0 214,0 240,0 253,0 277,0 84,7 84,9 101,3 107,7 127,1 163,0 163,0 163,2 173,0 176,0 38,8 39,4 44,4 46,7 51, scroll scroll scroll scroll scroll R410 R410 R410 R410 R410 83,1 102,2 83,7 113,3 113, /3/50 400/3/50 400/3/50 400/3/50 400/3/50 194,3 194,3 228,1 225,8 331,6 477,0 477,0 461,8 438,5 607,8 2,48 2,52 2,37 2,35 2,18 2,96 3,21 3,35 3,32 3,29 96,8 96,8 97,2 97,3 97,3 77,6 77,6 77,9 78,0 78, ,9 88,9 88,9 88,9 88,9 72,3 73,5 82,7 87,0 95,4 5,5 5,5 5,5 5,5 5,5 7,5 7,5 7,5 7,5 7, ,0 214,0 240,0 253,0 277,0 84,7 84,9 101,3 107,7 127,1 163,0 163,0 163,2 173,0 176, ,48 2,52 2,37 2,35 2,18 95,3 95,3 95,8 96,4 96,4 76,1 76,1 76,5 77,1 77,1 204,0 207,0 232,0 244,0 266,0 83,3 83,8 100,9 107,0 127,3 161,0 162,0 162,1 171,0 175, ,45 2,47 2,30 2,28 2,09 92,4 92,4 92,8 93,3 93,3 73,1 73,1 73,5 74,0 74,0 195,0 198,0 220,0 231,0 248,0 85,2 85,3 103,8 109,5 132,6 159,0 160,0 160,1 169,0 172, ,29 2,32 2,12 2,11 1,87 90,5 90,5 90,8 91,2 91,2 71,2 71,2 71,5 71,9 71,9 1. Referred to glycol solution temperature 15/10 C; 20% Ethylene glycol solution; air temperature to the condenser 35 C. Fouling factor of the exchangers 0,043 m² K/. 2. Referred to glycol solution inlet temperature 15 C; 20% Ethylene glycol solution; ambient temperature 3 C. Fouling factor of the exchangers 0,043 m² K/. 3. Sound power level [Lw] according to ISO EN verage sound pressure level [LPm] 1m far according to ISO EN Hydraulic connection with grooved end complete with flexible joint and adapter pipe for solder connection. 6. Referred to glycol solution temperature 15/10 C; 20% Ethylene glycol solution; air temperature to the condenser 35 C. Water temperature heat recovery 40/45 C 0% glycol solution; Fouling factor of the exchangers 0,043 m² K/ fiftycoolyears RCGROUP Sp G_ITC_RCW

132 MXIMO PF IT Cooling DIMENSIONS (mm) C a b c C C C C C c b a 132 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

133 EGLE FREE EGLE FREE: Packaged air cooled liquid chillers with free-cooling system for outdoor installation, equipped with scroll compressors and axial fans Cooling Capacity: Free-Cooling Capacity: FREECOOLING EGLE FREE FREE rcgroupairconditioning COOLING R410 PLTE C MIN FETURES ir cooled liquid chiller with free-cooling system. 17 models available, for a wide selection opportunity. verage step of 20. EER up to 2,92. ESEER up to 3,85. Scroll compressors. R410 Refrigerant charge. Single or double refrigerant circuit. Plate type heat exchangers. C xial fans. Single air circuit. Electronic expansion valve. Suitable for outdoor installation. MIN BENEFITS Units equipped with two scroll compressors for refrigerant circuit to reach a high efficiency. Units with single and double refrigerant circuits. Indirect free cooling system. vailability of EC axial fans for a high efficiency. vailability of kit for the reduction and the extreme reduction of the noise. vailability of pumping groups. vailability of partial heat recovery system. Easily of maintenance. Components dedicated to the safety of the unity. INDIRECT FREE COOLING SYSTEM Complete cooling of the chilled water of the existing cooling system with the outside air. The energy saving will be higher the longer the outside temperature remains below the required temperature for cooling. ELECTRONIC EXPNSION VLVE The electronic expansion valves are synonymous of an higher energy efficiency and stability of the system. WORKING LIMITS IN COOLING MODE Chilled water outlet temperature: 4 15 C mbient temperature: C WORKING LIMITS IN FREE-COOLING MODE Minimum chilled water outlet temperature: -15 C Minimum ambient temperature: -20 C fiftycoolyears fiftycoolyears RCGROUP Sp G_ITC_RCW

134 EGLE FREE MIN COMPONENTS FRMEWORK Base, self supporting frame and panelling in steel plate with protective surfaces treatment in compliance with UNI ISO 9227/STMB117 and ISO 7253, and painted with epoxy powders. Compressors compartment. Colour: RL 9002 COMPRESSORS Orbiting spiral (SCROLL) hermetic compressors with spiral profile optimized for R410 refrigerant. ON / OFF capacity control (0 / 100% each compressor). 2-pole 3-phase electric motor with direct on line starting. Phase sequence electronic relay. Crankcase heater. Electric motor thermal protection via internal winding temperature sensors. Rubber supports. EVPORTOR Copper brazed plate type with cover plates, plates and connections in ISI 316 stainless steel: - With single refrigerant circuit for S version machines. - With double refrigerant circuit for D version machines. nticondensate insulation made of polyurethane. Temperature sensors on water inlet and outlet. Water flow safety switch. ntifreeze heater. CONDENSING ND FREE-COOLING COIL Heat exchangers contained in single coil with high efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops. The combination of two factors, special tubes and fins, allow to optimally combine the following aspects: - Maximum capacity relative to the size of the exchanger. - Minimum charge of refrigerant. - Reduction of the air flow required for the heat exchange. Frame in galvanized steel. Motorized valves for free-cooling water circuit control. Temperature sensor on ambient air. ELECTRICL PNEL In accordance with EN norms, suitable for outdoor installation, complete with: Main switch with door lock safety. Magnetothermic switch or fuses for each compressor. Magnetothermic switches for fans or water pumps (if scheduled). Contactors for each load. Transformer for auxiliary circuit and microprocessor supply. Panel with machine controls. Power supply 400/3/50. CONTROL SYSTEM MP.COM microprocessor system with graphic display for control and monitor of operating and alarms status. The system includes: - Voltage free contact for remote general alarm. - Main components hour-meter. - Nonvolatile Flash memory for data storage. - Menu with protection password. - LN connection. - dditional module with the following inlets / outlets: INLETS o External alarm 1 o External alarm 2 o Line current indication. o Line voltage indication / Compensation o mbient air temperature OUTLETS o External alarm 1 o External alarm 2 o General alarm 2 o General alarm 3 - Driver for the additional module. IT Cooling FNS SECTION xial fans with sickle-shaped blades, fan guard and optimized for low noise levels. External rotor C type electric motor. Stepless variable speed with phase-cut electronic controller for condensing pressure control. Stepless variable speed with phase-cut electronic controller for free-cooling control. IP54 enclosure class. REFRIGERNT CIRCUIT Components for each refrigerant circuit: Electronic expansion valve. The valve allows high performance and system efficiency thanks to a timely and accurate response to changes in temperature and pressure. Sight glass. Filter dryer on liquid line. Service valves on liquid line and gas discharge. Liquid receiver with safety valve. Safety valve on low pressure side. Pressure transducers with indication, control and protection functions, on low and high refrigerant pressure. High pressure safety switch with manual reset. Refrigerant circuit with copper tubing with anticondensate insulation of the suction line. Plastic capillary hoses for pressure sensors connection. R410 refrigerant charge. 134 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

135 IT Cooling EGLE FREE OPTIONL CCESSORIES EGLE FREE Pumping group (1 pump) Pumping group (2 pumps) LNO kit (noise reduction) ELN kit (extremely noise reduction) Spring antivibration holders (kit) Rubber support (kit) Kit brine (for glycol solution production up to -6 C) Kit brine B (for glycol solution production up to -12 C) 79 - Electrical panel heating system EC fan Partial heat recovery Coils protection nets Condensing coil in special execution Glycol free Safety water flow switch Compr. power factor capacitor - 0, Soft Starter 83 - Compressor operation indicator Expansion valve energy reserve module nalogic flowmeter Power supply analyzer Multimeter kit Clock card RC-Com MBUS/JBUS Serial board LON Serial board BCnet Ethernet - SNMP - TCP/IP Serial board BCnet MS/TP Serial board Serial card for GSM Modem Data Logger Kit modem GSM Plantwatch without modem Remote graphic terminal kit Master plant SEQUENCER RC CLOUD PLTFORM N6 N7 N8 N9 N available accessory; - not available accessory fiftycoolyears RCGROUP Sp G_ITC_RCW

136 EGLE FREE IT Cooling TECHNICL DT EGLE FREE STNDRD OPTIONL LNO KIT 100% LNO KIT 85% ELN KIT EGLE FREE Cooling capacity (1) Free-Cooling capacity (2) Total water flow rate Total pressure drop kpa Compressors Quantity n. Capacity steps n. xial fans n. ir circuits n. Refrigerant Total refrigerant charge (optional excluded) Gas circuits n. Power supply V/Ph/Hz Max unit operating current (FL) Unit starting current (LR) EER (1) / ESEER Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) Net weight Hydraulic connections Evaporator IN/OUT - ISO 7/1 R Ø Evaporator IN/OUT - OD (5) Ø mm Partial heat recovery (6) Heating capacity Pumping group Power input Cooling capacity (1) Free-Cooling capacity (2) EER (1) / Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) Cooling capacity (1) Free-Cooling capacity (2) EER (1) / Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) Cooling capacity (1) Free-Cooling capacity (2) EER (1) / Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) T 60 P2 T 60 P2 T 70 P2 T 70 P2 T 90 P2 T 90 P2 T 120 P2 T 120 P2 S D S D S D S D N6 N6 N6 N6 N7 N7 N7 N7 69,7 69,7 79,8 79,6 104,0 103,0 126,0 124,0 24,0 23,9 28,8 28,5 36,9 36,5 47,7 47,3 47,5 47,5 51,4 51,4 64,2 63,9 71,3 71,0 12,8 12,8 14,7 14,7 19,1 18,9 23,3 22, scroll scroll scroll scroll scroll scroll scroll scroll R410 R410 R410 R410 R410 R410 R410 R410 31,6 34,6 32,0 35,6 42,0 40,8 42,9 41, /3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 67,6 67,6 73,9 73,9 92,2 92,2 110,0 110,0 173,4 173,4 209,4 209,4 272,8 272,8 328,3 328,3 2,90 2,92 2,77 2,79 2,82 2,82 2,64 2,62 3,78 3,49 3,68 3,31 3,58 3,31 3,53 3,15 83,3 83,3 83,8 83,8 92,3 92,3 92,5 92,5 66,3 66,3 66,4 66,4 74,2 74,2 74,4 74, " 2" 2" 2" ,1 76,1 76,1 76,1 24, , , ,4 -- 1,1 1,1 2,2 2,2 2,2 2,2 2,2 2,2 69,7 69,7 79,8 79,6 104,0 103,0 126,0 124,0 24,0 23,9 28,8 28,5 36,9 36,5 47,7 47,3 47,5 47,5 51,4 51,4 64,2 63,9 71,3 71, ,90 2,92 2,77 2,79 2,82 2,82 2,64 2,62 83,2 83,2 83,7 83,7 92,2 92,2 92,3 92,3 66,2 66,2 66,2 66,2 74,1 74,1 74,2 74,2 68,3 68,3 78,1 78,0 102,0 101,0 123,0 122,0 24,3 24,1 29,3 29,0 37,2 37,0 48,4 48,2 47,2 47,2 51,1 51,1 63,7 63,4 70,8 70, ,81 2,83 2,67 2,69 2,74 2,73 2,54 2,53 79,9 79,9 80,3 80,3 88,8 88,8 89,0 89,0 62,8 62,8 62,9 62,9 70,7 70,7 70,9 70,9 66,3 66,3 75,7 75,6 98,8 97,7 119,0 117,0 24,0 23,9 29,1 28,9 35,9 35,7 47,8 47,4 46,8 46,8 50,7 50,7 63,0 62,7 70,0 69, ,76 2,77 2,60 2,62 2,75 2,74 2,49 2,47 74,1 74,1 74,7 74,7 82,9 82,9 83,3 83,3 57,0 57,0 57,2 57,2 64,8 64,8 65,2 65,2 1. Referred to glycol solution temperature 15/10 C; 20% Ethylene glycol solution; air temperature to the condenser 35 C. Fouling factor of the exchangers 0,043 m² K/. 2. Referred to glycol solution inlet temperature 15 C; 20% Ethylene glycol solution; ambient temperature 3 C. Fouling factor of the exchangers 0,043 m² K/. 3. Sound power level [Lw] according to ISO EN verage sound pressure level [LPm] 1m far according to ISO EN Hydraulic connection with grooved end complete with flexible joint and adapter pipe for solder connection. 6. Referred to glycol solution temperature 15/10 C; 20% Ethylene glycol solution; air temperature to the condenser 35 C. Water temperature heat recovery 40/45 C 0% glycol solution; Fouling factor of the exchangers 0,043 m² K/. 136 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

137 IT Cooling EGLE FREE TECHNICL DT EGLE FREE STNDRD OPTIONL LNO KIT 100% LNO KIT 85% ELN KIT EGLE FREE Cooling capacity (1) Free-Cooling capacity (2) Total water flow rate Total pressure drop kpa Compressors Quantity n. Capacity steps n. xial fans n. ir circuits n. Refrigerant Total refrigerant charge (optional excluded) Gas circuits n. Power supply V/Ph/Hz Max unit operating current (FL) Unit starting current (LR) EER (1) / ESEER Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) Net weight Hydraulic connections Evaporator IN/OUT - ISO 7/1 R Ø Evaporator IN/OUT - OD (5) Ø mm Partial heat recovery (6) Heating capacity Pumping group Power input Cooling capacity (1) Free-Cooling capacity (2) EER (1) / Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) Cooling capacity (1) Free-Cooling capacity (2) EER (1) / Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) Cooling capacity (1) Free-Cooling capacity (2) EER (1) / Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) T 135 P2 T 150 P2 T 150 P2 T 190 P4 T 200 P2 T 200 P2 T 240 P4 T 270 P4 T 300 P4 S S D D S D D D D N7 N8 N8 N9 N8 N8 N9 N10 N10 141,0 168,0 171,0 202,0 203,0 208,0 247,0 292,0 331,0 55,7 60,4 60,6 76,2 79,0 80,6 99,2 112,7 126,8 73,8 108,0 109,0 117,0 118,0 119,0 132,0 176,0 194,0 26,1 31,0 31,4 37,3 37,4 38,4 45,6 53,9 60, scroll scroll scroll scroll scroll scroll scroll scroll scroll R410 R410 R410 R410 R410 R410 R410 R410 R410 43,6 62,6 64,6 68,4 66,4 67,0 68,0 94,2 95, /3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 127,8 149,6 149,6 180,3 184,5 188,6 220,1 263,8 299,3 366,3 387,1 387,1 356,7 477,7 481,6 433,1 495,8 529,6 2,53 2,78 2,82 2,65 2,57 2,58 2,49 2,59 2,61 3,47 3,60 3,33 3,85 3,49 3,09 3,64 3,64 3,74 93,5 95,4 95,4 94,8 94,8 94,8 100,0 101,8 101,8 75,4 76,0 76,0 75,4 75,4 75,4 80,2 81,5 81, ,1 88,9 88,9 88,9 88,9 88,9 88,9 88,9 88,9 48,6 57,8 58,7 69,6 69,8 71,7 85,0 101,0 114,0 2,2 4,0 4,0 4,0 4,0 4,0 4,0 5,5 7,5 141,0 168,0 171,0 202,0 203,0 208,0 247,0 292,0 331,0 55,7 60,4 60,6 76,2 79,0 80,6 99,2 112,7 126,8 73,8 108,0 109,0 117,0 118,0 119,0 132,0 176,0 194, ,53 2,78 2,82 2,65 2,57 2,58 2,49 2,59 2,61 93,3 95,2 95,2 94,6 94,6 94,6 96,3 97,5 97,5 75,2 75,8 75,8 75,3 75,3 75,3 76,5 77,2 77,2 138,0 164,0 167,0 197,0 198,0 203,0 240,0 285,0 323,0 56,8 61,4 61,6 77,9 80,5 81,5 101,3 114,0 129,2 73,3 108,0 108,0 117,0 118,0 118,0 131,0 175,0 193, ,43 2,67 2,71 2,53 2,46 2,49 2,37 2,50 2,50 90,0 91,9 91,9 91,3 91,3 91,3 93,3 94,6 94,6 71,9 72,5 72,5 71,9 71,9 71,9 73,5 74,2 74,2 132,0 159,0 161,0 190,0 190,0 195,0 231,0 275,0 311,0 56,7 59,8 60,1 78,2 80,2 79,6 100,4 110,4 125,4 72,4 107,0 107,0 115,0 116,0 117,0 130,0 174,0 192, ,33 2,66 2,68 2,43 2,37 2,45 2,30 2,49 2,48 84,3 86,0 86,0 85,6 85,6 85,6 88,2 89,7 89,7 65,7 66,6 66,6 66,3 66,3 66,3 68,4 69,4 69,4 1. Referred to glycol solution temperature 15/10 C; 20% Ethylene glycol solution; air temperature to the condenser 35 C. Fouling factor of the exchangers 0,043 m² K/. 2. Referred to glycol solution inlet temperature 15 C; 20% Ethylene glycol solution; ambient temperature 3 C. Fouling factor of the exchangers 0,043 m² K/. 3. Sound power level [Lw] according to ISO EN verage sound pressure level [LPm] 1m far according to ISO EN Hydraulic connection with grooved end complete with flexible joint and adapter pipe for solder connection. 6. Referred to glycol solution temperature 15/10 C; 20% Ethylene glycol solution; air temperature to the condenser 35 C. Water temperature heat recovery 40/45 C 0% glycol solution; Fouling factor of the exchangers 0,043 m² K/ fiftycoolyears RCGROUP Sp G_ITC_RCW

138 EGLE FREE IT Cooling DIMENSIONS (mm) N a b c N N N N N c b a 138 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

139 GLIDER EVO FREE GLIDER EVO FREE: Packaged air cooled liquid chillers with free-cooling system for outdoor installation, equipped with screw compressors and axial fans Cooling Capacity: Free-Cooling Capacity: GLYCOL FREECOOLING GLIDER EVO FREE R134a rcgroupairconditioning SHELL C FREE COOLING MIN FETURES ir cooled liquid chiller with free-cooling system. 21 models available, for a wide selection opportunity. verage step of 50. EER up to 2,74. ESEER up to 3,25. Twin-Screw compressors. R134a Refrigerant charge. Double refrigerant circuit. Shell and tube evaporator. C xial fans. Double air circuit. Electronic expansion valve. Suitable for outdoor installation. INDIRECT FREE COOLING SYSTEM Complete cooling of the chilled water of the existing cooling system with the outside air. The energy saving will be higher the longer the outside temperature remains below the required temperature for cooling. WORKING LIMITS IN COOLING MODE Chilled water outlet temperature: C mbient temperature: C WORKING LIMITS IN FREE-COOLING MODE Minimum chilled water outlet temperature: -15 C Minimum ambient temperature: -20 C MIN BENEFITS Indirect free cooling system. vailability of Glycol Free system. Low footprint. vailability of kit for the reduction and the extreme reduction of the noise. vailability of pumping groups. vailability of partial heat recovery system. vailability of EC axial fans for a higher efficiency. Complete set of components dedicated to the safety of the unity fiftycoolyears fiftycoolyears RCGROUP Sp G_ITC_RCW

140 GLIDER EVO FREE MIN COMPONENTS FRMEWORK Base, self supporting frame and panelling in steel plate with protective surfaces treatment in compliance with UNI ISO 9227/STMB117 and ISO 7253, and painted with epoxy powders. Colour: RL 9002 COMPRESSORS Twin screw semi-hermetic compressors with highly efficient screw profile and high peripheral speed, optimized for R134a refrigerant. Integrated discharge check valve. Flanged-on oil separator. Integrated safety relief valve (overpressure inner valve). Replaceable cartridge type oil filter. Valves for oil filling and discharge. Oil sight glass. Electronic protection device that includes: - Electric motor thermal protection via internal winding temperature sensors. - Phase sequence electronic relay - Sensor on refrigerant discharge for temperature monitoring, 2-pole 3-phase electric motor with Part-Winding starting from model 290 V2 F06 to model 470 V2 F08 included. 2-pole 3-phase electric motor with Star / Delta starting from model 520 V2 F08 to model 1220 V2 F16 included. Stepless capacity control, % for each compressor. Crankcase heater. Terminal box with IP54 enclosure class. Rubber supports. EVPORTOR Single pass type shell and tube evaporator optimized for R134a refrigerant. Tubes with a helical rifled internal surface. Intermediate baffles positioned to ensure optimum speed of the fluid and low pressure drops. Single circuit on water side and independent circuits, one for each compressor, on refrigerant side. Shell, header, tube sheets, made of carbon steel, tubes in Cu. nticondensate insulation made of polyurethane. Temperature sensors on water inlet and outlet. Hydraulic connections with grooved end supplied as standard with flexible joint and adapter pipe to be welded. CONDENSING ND FREE-COOLING COIL Heat exchangers contained in single coil with high efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops. The combination of two factors, special tubes and fins, allow to optimally combine the following aspects: - Maximum capacity relative to the size of the exchanger. - Minimum charge of refrigerant. - Reduction of the air flow required for the heat exchange. Frame in galvanized steel. Motorized valves for free-cooling water circuit control. Temperature sensor on ambient air. IT Cooling REFRIGERNT CIRCUIT Component for each refrigerant circuit: Electronic expansion valve that allows high performance and system efficiency thanks to a timely and accurate response to changes in temperature and pressure. Energy reserve module for the electronic expansion valve to allow the closure of the valve in the event of lack of power supply. Sight glass. Filter dryer on liquid line. Service valves on liquid line. Service valves on compressor gas discharge. Double safety valve (only one in function) on high and low pressure side. The system include two safety valves with manual changeover system. Pressure transducers with indication, control and protection functions, on low and high refrigerant pressure and oil pressure. High pressure safety switch with manual reset. Pressure gauge on high and low pressure. Refrigerant circuit with copper tubing with anticondensate insulation of the suction line. Plastic capillary hoses for pressure sensors connection. R134a refrigerant charge. ELECTRICL PNEL In accordance with EN norms, suitable for outdoor installation, complete with: Main switch with door lock safety. Fuses for each compressor. Magnetothermic switches for fans. Fuses for water pumps (if scheduled). Contactors for each load. Compressor Part-Winding starting system from model 290 V2 F06 to model 470 V2 F08 included. Compressor Star / Delta starting system from model 520 V2 F08 to model 1220 V2 F16 included. Transformer for auxiliary circuit and microprocessor supply. Panel with machine controls. Power supply 400/3/50. CONTROL SYSTEM MP.COM microprocessor system with graphic display for control and monitor of operating and alarms status. The system includes: - Voltage free contact for remote general alarm. - Main components hour-meter. - Nonvolatile Flash memory for data storage. - Menu with protection password. - LN connection. dditional module 1 for ambient air temperature inlet. Driver for the additional module 1. FNS SECTION xial fans with sickle-shaped blades, fan guard and optimized for low noise levels. External rotor C type electric motor. Stepless variable speed with phase-cut electronic controller for condensing pressure control. Stepless variable speed with phase-cut electronic controller for free-cooling control. IP54 enclosure class. 140 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

141 IT Cooling GLIDER EVO FREE OPTIONL CCESSORIES GLIDER EVO FREE Pumping group (1 pump) Pumping group (1+1stby) Pumping group (2 pumps) Pumping group (2+1stby) ntifreeazing heater for pumping group Kit brine (for glycol solution production up to -6 C) Kit brine B (for glycol solution production up to -12 C) Pipes antifreezing kit 79 - Electrical panel heating system LNO kit (noise reduction) ELN kit (extremely noise reduction) Spring antivibration holders (kit) Rubber antivibration holders (kit) EC fan Condensing pressure / free cooling control system Partial heat recovery Voltage free contact for partial heat recovery water pump activation Condensing coil in special execution Coils protection nets Free Cooling Coils with pre-painted fins Safety water flow switch Safety oil flow switch Glycol free Compressor thermal relay Compr. power factor capacitor - 0,9 Supply network control relay 83 - Compressor operation indicator Stop valve on compressor suction line 85 - Demand limit 88 - nalog set point compensation nalogic flowmeter Power supply analyzer Multimeter kit Clock card RC-Com MBUS/JBUS Serial board LON Serial board BCnet Ethernet - SNMP - TCP/IP Serial board BCnet MS/TP Serial board MP.COM expansion card Serial card for GSM Modem Data Logger Kit modem GSM Plantwatch without modem Remote graphic terminal kit Master plant SEQUENCER RC CLOUD PLTFORM F06 F08 F10 F12 F14 F16 * - - * ** ** available accessory; - not available accessory * up to model 930 V2, ** from model 980 V fiftycoolyears RCGROUP Sp G_ITC_RCW

142 GLIDER EVO FREE IT Cooling TECHNICL DT GLIDER EVO FREE STNDRD OPTIONL GLIDER EVO FREE Cooling capacity (1) Free-Cooling capacity (2) Total water flow rate kpa Total pressure drop Compressors Quantity n. Capacity control % xial fans n. ir circuits n. Refrigerant Total refrigerant charge (optional excluded) Gas circuits n. Power supply V/Ph/Hz Max unit operating current (FL) Unit starting current (LR) EER (1) / ESEER Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) Net weight Hydraulic connections Evaporator IN/OUT - OD (5) Ø mm Glycol free system (2) Free-Cooling capacity Glycol free water pump power input Partial heat recovery (6) 290 V2 310 V2 330 V2 350 V2 370 V2 410 V2 440 V2 470 V2 F06 F06 F06 F06 F06 F08 F08 F ,0 124,5 135,2 144,9 154,3 169,9 181,5 195, ,3 61,0 65,5 69,3 73,3 81,1 86,3 91, twin-screw twin-screw twin-screw twin-screw twin-screw twin-screw twin-screw twin-screw % % % % % % % % R134a R134a R134a R134a R134a R134a R134a R134a /3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 285,0 306,0 327,0 345,9 364,8 358,3 386,6 415,0 415,7 475,7 489,6 562,6 576,2 611,2 692,2 714,6 2,73 2,73 2,70 2,67 2,65 2,66 2,65 2,61 3,04 3,09 3,08 3,10 3,10 3,07 3,08 3,08 91,4 91,6 91,7 91,7 91,8 92,1 94,5 96,1 71,7 71,8 71,9 72,0 72,0 71,9 74,3 75, ,7 139,7 139,7 139,7 139,7 139,7 139,7 139, ,5 5,5 5,5 5,5 5,5 5,5 5,5 5,5 Heating capacity 61,9 67,0 71,9 76,2 80,5 89,1 94,8 101,0 Pumping group Power input 7,5 7,5 7,5 7,5 7,5 7,5 7,5 7,5 Cooling capacity (1) ,0 124,5 135,2 144,9 154,3 169,9 181,5 195,4 Free-Cooling capacity (2) EER (1) / 2,73 2,73 2,70 2,67 2,65 2,66 2,65 2,61 Sound power level [Lw] (3) 89,4 89,6 89,7 89,7 89,8 90,1 92,5 94,1 verage sound pressure level [Lpm] (4) 69,7 69,8 69,9 70,0 70,0 69,9 72,3 73,9 Cooling capacity (1) ,8 125,7 136,8 147,8 157,9 171,7 185,0 198,8 Free-Cooling capacity (2) EER (1) / 2,66 2,65 2,61 2,55 2,52 2,58 2,54 2,50 Sound power level [Lw] (3) 88,4 88,6 88,7 88,7 88,8 89,1 91,5 93,1 verage sound pressure level [Lpm] (4) 68,7 68,8 68,9 69,0 69,0 68,9 71,3 72,9 Cooling capacity (1) ,7 129,8 142,0 153,2 163,9 176,2 191,2 205,6 Free-Cooling capacity (2) EER (1) / 2,52 2,48 2,43 2,37 2,33 2,44 2,38 2,33 Sound power level [Lw] (3) 85,4 85,6 85,7 85,7 85,8 86,1 88,5 90,1 verage sound pressure level [Lpm] (4) 65,7 65,8 65,9 66,0 66,0 65,9 68,3 69,9 Cooling capacity (1) ,7 129,8 142,0 153,2 163,9 176,2 191,2 205,6 Free-Cooling capacity (2) EER (1) / 2,52 2,48 2,43 2,37 2,33 2,44 2,38 2,33 Sound power level [Lw] (3) 82,4 82,6 82,7 82,7 82,8 83,1 85,5 87,1 verage sound pressure level [Lpm] (4) 62,7 62,8 62,9 63,0 63,0 62,9 65,3 66,9 1. Referred to glycol solution temperature 15/10 C; 20% Ethylene glycol solution; air temperature to the condenser 35 C. Fouling factor of the exchangers 0,043 m² K/. 2. Referred to glycol solution inlet temperature 15 C; 20% Ethylene glycol solution; ambient temperature 3 C. Fouling factor of the exchangers 0,043 m² K/. 3. Sound power level [Lw] according to ISO EN verage sound pressure level [LPm] 1m far according to ISO EN Hydraulic connection with grooved end complete with flexible joint and adapter pipe for solder connection. 6. Referred to glycol solution temperature 15/10 C; 20% Ethylene glycol solution; air temperature to the condenser 35 C. Water temperature heat recovery 40/45 C 0% glycol solution; Fouling factor of the exchangers 0,043 m² K/. LNO KIT 100% LNO KIT 85% LNO KIT 70% ELN KIT 142 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

143 IT Cooling GLIDER EVO FREE TECHNICL DT GLIDER EVO FREE STNDRD OPTIONL GLIDER EVO FREE Cooling capacity (1) Free-Cooling capacity (2) Total water flow rate kpa Total pressure drop Compressors Quantity n. Capacity control % xial fans n. ir circuits n. Refrigerant Total refrigerant charge (optional excluded) Gas circuits n. Power supply V/Ph/Hz Max unit operating current (FL) Unit starting current (LR) EER (1) / ESEER Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) Net weight Hydraulic connections Evaporator IN/OUT - OD (5) Ø mm Glycol free system (2) Free-Cooling capacity Glycol free water pump power input Partial heat recovery (6) 520 V2 550 V2 610 V2 670 V2 720 V2 770 V2 810 V2 870 V2 F08 F08 F08 F10 F10 F10 F10 F ,7 235,3 255,3 271,6 290,5 309,5 334,7 366, twin-screw twin-screw twin-screw twin-screw twin-screw twin-screw twin-screw twin-screw % % % % % % % % R134a R134a R134a R134a R134a R134a R134a R134a /3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 444,4 463,3 482,2 559,7 629,0 660,5 692,0 710,6 529,9 556,9 581,2 684,0 709,0 738,0 762,0 890,8 2,58 2,55 2,64 2,71 2,74 2,73 2,65 2,60 3,05 3,05 3,19 3,18 3,25 3,21 3,22 3,17 96,1 97,5 98,6 99,3 99,9 99,8 99,6 100,0 75,9 77,3 78,4 78,7 79,2 79,1 79,0 79, ,7 139,7 139,7 168,3 168,3 168,3 168,3 168, ,5 7,5 15,0 15,0 15,0 15,0 15,0 15,0 Heating capacity Pumping group Power input 7,5 7,5 7,5 7,5 7,5 7,5 7,5 7,5 Cooling capacity (1) ,7 235,3 255,3 271,6 290,5 309,5 334,7 366,2 Free-Cooling capacity (2) EER (1) / 2,58 2,55 2,64 2,71 2,74 2,73 2,65 2,60 Sound power level [Lw] (3) 94,1 95,5 96,6 97,3 97,9 97,8 97,6 98,0 verage sound pressure level [Lpm] (4) 73,9 75,3 76,4 76,7 77,2 77,1 77,0 77,0 Cooling capacity (1) ,9 241,9 263,3 279,3 298,4 319,1 345,2 375,2 Free-Cooling capacity (2) EER (1) / 2,44 2,41 2,48 2,56 2,58 2,56 2,48 2,46 Sound power level [Lw] (3) 93,1 94,5 95,6 96,3 96,9 96,8 96,6 97,0 verage sound pressure level [Lpm] (4) 72,9 74,3 75,4 75,7 76,2 76,1 76,0 76,0 Cooling capacity (1) ,3 253,6 276,9 290,3 311,4 332,9 361,3 392,4 Free-Cooling capacity (2) EER (1) / 2,25 2,20 2,25 2,36 2,36 2,34 2,25 2,25 Sound power level [Lw] (3) 90,1 91,5 92,6 93,3 93,9 93,8 93,6 94,0 verage sound pressure level [Lpm] (4) 69,9 71,3 72,4 72,7 73,2 73,1 73,0 73,0 Cooling capacity (1) ,3 253,6 276,9 290,3 311,4 332,9 361,3 392,4 Free-Cooling capacity (2) EER (1) / 2,25 2,20 2,25 2,36 2,36 2,34 2,25 2,25 Sound power level [Lw] (3) 87,1 88,5 89,6 90,3 90,9 90,8 90,6 91,0 verage sound pressure level [Lpm] (4) 66,9 68,3 69,4 69,7 70,2 70,1 70,0 70,0 1. Referred to glycol solution temperature 15/10 C; 20% Ethylene glycol solution; air temperature to the condenser 35 C. Fouling factor of the exchangers 0,043 m² K/. 2. Referred to glycol solution inlet temperature 15 C; 20% Ethylene glycol solution; ambient temperature 3 C. Fouling factor of the exchangers 0,043 m² K/. 3. Sound power level [Lw] according to ISO EN verage sound pressure level [LPm] 1m far according to ISO EN Hydraulic connection with grooved end complete with flexible joint and adapter pipe for solder connection. 6. Referred to glycol solution temperature 15/10 C; 20% Ethylene glycol solution; air temperature to the condenser 35 C. Water temperature heat recovery 40/45 C 0% glycol solution; Fouling factor of the exchangers 0,043 m² K/. LNO KIT 100% LNO KIT 85% LNO KIT 70% ELN KIT fiftycoolyears RCGROUP Sp G_ITC_RCW

144 GLIDER EVO FREE IT Cooling TECHNICL DT GLIDER EVO FREE STNDRD OPTIONL LNO KIT 100% LNO KIT 85% LNO KIT 70% ELN KIT GLIDER EVO FREE Cooling capacity (1) Free-Cooling capacity (2) Total water flow rate kpa Total pressure drop Compressors Quantity n. Capacity control % xial fans n. ir circuits n. Refrigerant Total refrigerant charge (optional excluded) Gas circuits n. Power supply V/Ph/Hz Max unit operating current (FL) Unit starting current (LR) EER (1) / ESEER Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) Net weight Hydraulic connections Evaporator IN/OUT - OD (5) Ø mm Glycol free system (2) Free-Cooling capacity Glycol free water pump power input Partial heat recovery (6) Heating capacity Pumping group Power input Cooling capacity (1) Free-Cooling capacity (2) EER (1) / Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) Cooling capacity (1) Free-Cooling capacity (2) EER (1) / Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) Cooling capacity (1) Free-Cooling capacity (2) EER (1) / Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) Cooling capacity (1) Free-Cooling capacity (2) EER (1) / Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) 930 V2 980 V V V V2 F12 F12 F12 F14 F ,2 416,7 438,9 470,7 512, twin-screw twin-screw twin-screw twin-screw twin-screw % % % % % R134a R134a R134a R134a R134a /3/50 400/3/50 400/3/50 400/3/50 400/3/50 721,1 763,1 805,1 924,6 1004,2 938,8 1002,8 1041,8 1247,6 1402,4 2,58 2,57 2,57 2,63 2,62 3,19 3,21 3,16 3,24 3,13 99,2 100,9 102,1 102,1 102,4 78,2 79,8 81,0 80,7 80, ,3 168,3 168,3 168,3 168, ,0 15,0 15,0 15,0 15, ,5 15,0 15,0 15,0 15, ,2 416,7 438,9 470,7 512, ,58 2,57 2,57 2,63 2,62 97,2 98,9 100,1 100,1 100,4 76,2 77,8 79,0 78,7 78, ,9 430,8 453,8 486,6 527, ,43 2,40 2,40 2,46 2,47 96,2 97,9 99,1 99,1 99,4 75,2 76,8 78,0 77,7 77, ,4 452,5 480,5 510,3 551, ,21 2,17 2,15 2,23 2,26 93,2 94,9 96,1 96,1 96,4 72,2 73,8 75,0 74,7 74, ,4 452,5 480,5 510,3 551, ,21 2,17 2,15 2,23 2,26 90,2 91,9 93,1 93,1 93,4 69,2 70,8 72,0 71,7 71,6 1. Referred to glycol solution temperature 15/10 C; 20% Ethylene glycol solution; air temperature to the condenser 35 C. Fouling factor of the exchangers 0,043 m² K/. 2. Referred to glycol solution inlet temperature 15 C; 20% Ethylene glycol solution; ambient temperature 3 C. Fouling factor of the exchangers 0,043 m² K/. 3. Sound power level [Lw] according to ISO EN verage sound pressure level [LPm] 1m far according to ISO EN Hydraulic connection with grooved end complete with flexible joint and adapter pipe for solder connection. 6. Referred to glycol solution temperature 15/10 C; 20% Ethylene glycol solution; air temperature to the condenser 35 C. Water temperature heat recovery 40/45 C 0% glycol solution; Fouling factor of the exchangers 0,043 m² K/. DIMENSIONS (mm) F a b c F F F F F F b a c 144 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

145 GLIDER EVO FREE CL GLIDER EVO FREE CL: Packaged air cooled liquid chillers with free-cooling system in class energy efficiency, for outdoor installation, equipped with screw compressors and axial fans Cooling Capacity: Free-Cooling Capacity: HIGHEFFICIENCY CLSS GLYCOL FREECOOLING GLIDER EVO FREE CL R134a rcgroupairconditioning CLSS SHELL C FREE COOLING MIN FETURES ir cooled liquid chiller with free-cooling system in class energy efficiency. 24 models available, for a wide selection opportunity. verage step of 50. EER up to 3,34. ESEER up to 3,83. Twin-Screw compressors. R134a Refrigerant charge. Double refrigerant circuit. Shell and tube evaporator. C xial fans. Double air circuit. Electronic expansion valve. Suitable for outdoor installation. MIN BENEFITS Indirect free cooling system. vailability of Glycol Free system. High EER and ESEER, class energy efficiency. vailability of kit for the reduction and the extreme reduction of the noise. vailability of pumping groups. vailability of partial heat recovery system. vailability of EC axial fans for a higher efficiency. Complete set of components dedicated to the safety of the unity. INDIRECT FREE COOLING SYSTEM: Complete cooling of the chilled water of the existing cooling system with the outside air. The energy saving will be higher the longer the outside temperature remains below the required temperature for cooling. GLYCOL FREE: The accessory allows to use pure water instead of antifreeze solutions in the hydraulic circuit of the plant. CLSS ENERGY EFFICIENCY: The best and most accurate components applied to the chillers. WORKING LIMITS IN COOLING MODE Chilled water outlet temperature: C mbient temperature: C WORKING LIMITS IN FREE-COOLING MODE Minimum chilled water outlet temperature: -15 C Minimum ambient temperature: -20 C fiftycoolyears fiftycoolyears RCGROUP Sp G_ITC_RCW

146 GLIDER EVO FREE CL MIN COMPONENTS FRMEWORK Base, self supporting frame and panelling in steel plate with protective surfaces treatment in compliance with UNI ISO 9227/STMB117 and ISO 7253, and painted with epoxy powders. Colour: RL 9002 COMPRESSORS Twin screw semi-hermetic compressors with highly efficient screw profile and high peripheral speed, optimized for R134a refrigerant. Integrated discharge check valve. Flanged-on oil separator. Integrated safety relief valve (overpressure inner valve). Replaceable cartridge type oil filter. Valves for oil filling and discharge. Oil sight glass. Electronic protection device that includes: - Electric motor thermal protection via internal winding temperature sensors. - Phase sequence electronic relay - Sensor on refrigerant discharge for temperature monitoring, 2-pole 3-phase electric motor with Part-Winding starting from model 290 V2 F06 to model 590 V2 F10 included. 2-pole 3-phase electric motor with Star / Delta starting from model 630 V2 F12 to model 1450 V2 F24 included. Stepless capacity control, % for each compressor. Crankcase heater. Terminal box with IP54 enclosure class. Rubber supports. EVPORTOR Single pass type shell and tube evaporator optimized for R134a refrigerant. Tubes with a helical rifled internal surface. Intermediate baffles positioned to ensure optimum speed of the fluid and low pressure drops. Single circuit on water side and independent circuits, one for each compressor, on refrigerant side. Shell, header, tube sheets, made of carbon steel, tubes in Cu. nticondensate insulation made of polyurethane. Temperature sensors on water inlet and outlet. Hydraulic connections with grooved end supplied as standard with flexible joint and adapter pipe to be welded. CONDENSING ND FREE-COOLING COIL Heat exchangers contained in single coil with high efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops. The combination of two factors, special tubes and fins, allow to optimally combine the following aspects: - Maximum capacity relative to the size of the exchanger. - Minimum charge of refrigerant. - Reduction of the air flow required for the heat exchange. Frame in galvanized steel. Motorized valves for free-cooling water circuit control. Temperature sensor on ambient air. IT Cooling REFRIGERNT CIRCUIT Component for each refrigerant circuit: Electronic expansion valve that allows high performance and system efficiency thanks to a timely and accurate response to changes in temperature and pressure. Energy reserve module for the electronic expansion valve to allow the closure of the valve in the event of lack of power supply. Sight glass. Filter dryer on liquid line. Service valves on liquid line. Service valves on compressor gas discharge. Double safety valve (only one in function) on high and low pressure side. The system include two safety valves with manual changeover system. Pressure transducers with indication, control and protection functions, on low and high refrigerant pressure and oil pressure. High pressure safety switch with manual reset. Pressure gauge on high and low pressure. Refrigerant circuit with copper tubing with anticondensate insulation of the suction line. Plastic capillary hoses for pressure sensors connection. R134a refrigerant charge. ELECTRICL PNEL In accordance with EN norms, suitable for outdoor installation, complete with: Main switch with door lock safety. Fuses for each compressor. Magnetothermic switches for fans. Fuses for water pumps (if scheduled). Contactors for each load. Compressor Part-Winding starting system from model 290 V2 F06 to model 590 V2 F10 included. Compressor Star / Delta starting system from model 630 V2 F12 to model 1450 V2 F24 included. Transformer for auxiliary circuit and microprocessor supply. Panel with machine controls. Power supply 400/3/50. CONTROL SYSTEM MP.COM microprocessor system with graphic display for control and monitor of operating and alarms status. The system includes: - Voltage free contact for remote general alarm. - Main components hour-meter. - Nonvolatile Flash memory for data storage. - Menu with protection password. - LN connection. dditional module 1 for ambient air temperature inlet. Driver for the additional module 1. FNS SECTION xial fans with sickle-shaped blades, fan guard and optimized for low noise levels. External rotor C type electric motor. Stepless variable speed with phase-cut electronic controller for condensing pressure control. Stepless variable speed with phase-cut electronic controller for free-cooling control. IP54 enclosure class. 146 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

147 IT Cooling GLIDER EVO FREE CL OPTIONL CCESSORIES GLIDER EVO FREE CL Pumping group (1 pump) Pumping group (1+1stby) Pumping group (2 pumps) Pumping group (2+1stby) ntifreeazing heater for pumping group Kit brine (for glycol solution production up to -6 C) Kit brine B (for glycol solution production up to -12 C) Pipes antifreezing kit 79 - Electrical panel heating system LNO kit (noise reduction) ELN kit (extremely noise reduction) Spring antivibration holders (kit) Rubber antivibration holders (kit) EC fan Condensing pressure / Free cooling control system Partial heat recovery Voltage free contact for partial heat recovery water pump activation Condensing coil in special execution Coils protection nets (kit) Safety water flow switch Safety oil flow switch Glycol free Compressor thermal relay Compr. power factor capacitor - 0,9 Supply network control relay 83 - Compressor operation indicator Stop valve on compressor suction line 85 - Demand limit 88 - nalog set point compensation nalogic flowmeter Power supply analyzer Multimeter kit Clock card RC-Com MBUS/JBUS Serial board LON Serial board BCnet Ethernet - SNMP - TCP/IP Serial board BCnet MS/TP Serial board MP.COM expansion card Serial card for GSM Modem Data Logger Kit modem GSM Plantwatch without modem Remote graphic terminal kit Master plant SEQUENCER RC CLOUD PLTFORM F06 F08 F10 F12 F14 F16 F18 F20 F22 F available accessory; - not available accessory fiftycoolyears RCGROUP Sp G_ITC_RCW

148 GLIDER EVO FREE CL IT Cooling TECHNICL DT GLIDER EVO FREE CL STNDRD OPTIONL LNO KIT 100% LNO KIT 85% LNO KIT 70% ELN KIT GLIDER EVO FREE CL Cooling capacity (1) Free-Cooling capacity (2) Evaporator water flow rate kpa Evaporator pressure drop Compressors Quantity n. Capacity control % xial fans n. ir circuits n. Refrigerant Total refrigerant charge (optional excluded) Gas circuits n. Power supply V/Ph/Hz Max unit operating current (FL) Unit starting current (LR) EER (1) / ESEER Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) Net weight Hydraulic connections Evaporator IN/OUT - OD (5) Ø mm Glycol free system (2) Free-Cooling capacity Glycol free water pump power input Partial heat recovery (6) Heating capacity Pumping group Power input Cooling capacity (1) Free-Cooling capacity (2) EER (1) / Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) Cooling capacity (1) Free-Cooling capacity (2) EER (1) / Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) Cooling capacity (1) Free-Cooling capacity (2) EER (1) / Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) Cooling capacity (1) Free-Cooling capacity (2) EER (1) / Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) 290 V2 310 V2 330 V2 360 V2 380 V2 420 V2 460 V2 490 V2 F06 F06 F08 F08 F08 F08 F10 F ,5 100,9 109,1 117,7 124,7 138,3 151,4 162, ,2 60,0 64,6 69,2 73,2 80,8 89,8 95, twin-screw twin-screw twin-screw twin-screw twin-screw twin-screw twin-screw twin-screw % % % % % % % % R134a R134a R134a R134a R134a R134a R134a R134a /3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 251,4 230,4 261,8 293,2 293,2 335,2 381,2 366,5 400,4 388,4 418,3 445,2 445,2 525,2 624,0 633,0 3,34 3,32 3,31 3,28 3,28 3,26 3,31 3,28 3,78 3,77 3,78 3,74 3,76 3,77 3,74 3,75 92,1 92,5 92,7 92,9 91,5 91,9 92,1 96,2 72,4 72,8 72,5 72,7 71,3 71,7 71,4 75, ,7 139,7 139,7 139,7 139,7 139,7 139,7 139, ,5 5,5 5,5 5,5 5,5 5,5 5,5 5,5 62,9 66,0 71,1 76,1 80,6 88,9 98,8 105,0 7,5 7,5 7,5 7,5 7,5 7,5 7,5 7, ,5 100,9 109,1 117,7 124,7 138,3 151,4 162, ,34 3,32 3,31 3,28 3,28 3,26 3,31 3,28 90,1 90,5 90,7 90,9 89,5 89,9 90,1 94,2 70,4 70,8 70,5 70,7 69,3 69,7 69,4 73, ,4 102,5 110,2 117,9 125,1 140,8 152,1 164, ,28 3,22 3,23 3,24 3,23 3,16 3,26 3,18 89,1 89,5 89,7 89,9 88,5 88,9 89,1 93,2 69,4 69,8 69,5 69,7 68,3 68,7 68,4 72, ,5 106,3 112,6 120,2 128,5 144,4 156,1 168, ,16 3,03 3,10 3,12 3,09 3,02 3,12 3,02 86,1 86,5 86,7 86,9 85,5 85,9 86,1 90,2 66,4 66,8 66,5 66,7 65,3 65,7 65,4 69, ,5 106,3 112,6 120,2 128,5 144,4 156,1 168, ,16 3,03 3,10 3,12 3,09 3,02 3,12 3,02 83,1 83,5 83,7 83,9 82,5 82,9 83,1 87,2 63,4 63,8 63,5 63,7 62,3 62,7 62,4 66,6 1. Referred to glycol solution temperature 15/10 C; 20% Ethylene glycol solution; air temperature to the condenser 35 C. Fouling factor of the exchangers 0,043 m² K/. 2. Referred to glycol solution inlet temperature 15 C; 20% Ethylene glycol solution; ambient temperature 3 C. Fouling factor of the exchangers 0,043 m² K/. 3. Sound power level [Lw] according to ISO EN verage sound pressure level [LPm] 1m far according to ISO EN Hydraulic connection with grooved end complete with flexible joint and adapter pipe for solder connection. 6. Referred to glycol solution temperature 15/10 C; 20% Ethylene glycol solution; air temperature to the condenser 35 C. Water temperature heat recovery 40/45 C 0% glycol solution; Fouling factor of the exchangers 0,043 m² K/. 148 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

149 IT Cooling GLIDER EVO FREE CL TECHNICL DT GLIDER EVO FREE CL STNDRD OPTIONL LNO KIT 100% LNO KIT 85% LNO KIT 70% ELN KIT GLIDER EVO FREE CL Cooling capacity (1) Free-Cooling capacity (2) Evaporator water flow rate kpa Evaporator pressure drop Compressors Quantity n. Capacity control % xial fans n. ir circuits n. Refrigerant Total refrigerant charge (optional excluded) Gas circuits n. Power supply V/Ph/Hz Max unit operating current (FL) Unit starting current (LR) EER (1) / ESEER Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) Net weight Hydraulic connections Evaporator IN/OUT - OD (5) Ø mm Glycol free system (2) Free-Cooling capacity Glycol free water pump power input Partial heat recovery (6) Heating capacity Pumping group Power input Cooling capacity (1) Free-Cooling capacity (2) EER (1) / Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) Cooling capacity (1) Free-Cooling capacity (2) EER (1) / Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) Cooling capacity (1) Free-Cooling capacity (2) EER (1) / Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) Cooling capacity (1) Free-Cooling capacity (2) EER (1) / Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) 540 V2 590 V2 630 V2 680 V2 720 V2 790 V2 860 V2 910 V2 F10 F10 F12 F14 F14 F16 F16 F ,6 195,1 210,7 228,3 244,1 266,4 291,0 308, ,0 114,0 124,0 132,0 140,0 155,0 169,0 178, twin-screw twin-screw twin-screw twin-screw twin-screw twin-screw twin-screw twin-screw % % % % % % % % R134a R134a R134a R134a R134a R134a R134a R134a , , /3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 394,8 423,2 460,7 483,7 506,7 580,1 653,5 685,0 714,0 741,0 556,8 587,7 609,6 708,5 778,4 808,4 3,27 3,27 3,28 3,22 3,20 3,24 3,24 3,22 3,75 3,75 3,71 3,72 3,77 3,74 3,72 3,71 96,5 96,7 97,7 99,3 100,4 101,1 101,7 101,6 75,8 76,0 76,7 77,9 79,0 79,3 79,9 79, ,7 139,7 139,7 139,7 139,7 168,3 168,3 168, ,5 7,5 7,5 7,5 7,5 15,0 15,0 15,0 115,0 126,0 136,0 145,0 154,0 170,0 186,0 196,0 7,5 7,5 7,5 7,5 7,5 15,0 15,0 15, ,6 195,1 210,7 228,3 244,1 266,4 291,0 308, ,27 3,27 3,28 3,22 3,20 3,24 3,24 3,22 94,5 94,7 95,7 97,3 98,4 99,1 99,7 99,6 73,8 74,0 74,7 75,9 77,0 77,3 77,9 77, ,6 197,8 213,5 231,0 246,2 269,8 294,9 312, ,16 3,17 3,19 3,13 3,12 3,15 3,15 3,12 93,5 93,7 94,7 96,3 97,4 98,1 98,7 98,6 72,8 73,0 73,7 74,9 76,0 76,3 76,9 76, ,0 204,3 218,8 236,6 252,7 275,7 302,3 321, ,99 2,99 3,04 2,98 2,96 3,01 3,00 2,96 90,5 90,7 91,7 93,3 94,4 95,1 95,7 95,6 69,8 70,0 70,7 71,9 73,0 73,3 73,9 73, ,0 204,3 218,8 236,6 252,7 275,7 302,3 321, ,99 2,99 3,04 2,98 2,96 3,01 3,00 2,96 87,5 87,7 88,7 90,3 91,4 92,1 92,7 92,6 66,8 67,0 67,7 68,9 70,0 70,3 70,9 70,8 1. Referred to glycol solution temperature 15/10 C; 20% Ethylene glycol solution; air temperature to the condenser 35 C. Fouling factor of the exchangers 0,043 m² K/. 2. Referred to glycol solution inlet temperature 15 C; 20% Ethylene glycol solution; ambient temperature 3 C. Fouling factor of the exchangers 0,043 m² K/. 3. Sound power level [Lw] according to ISO EN verage sound pressure level [LPm] 1m far according to ISO EN Hydraulic connection with grooved end complete with flexible joint and adapter pipe for solder connection. 6. Referred to glycol solution temperature 15/10 C; 20% Ethylene glycol solution; air temperature to the condenser 35 C. Water temperature heat recovery 40/45 C 0% glycol solution; Fouling factor of the exchangers 0,043 m² K/ fiftycoolyears RCGROUP Sp G_ITC_RCW

150 GLIDER EVO FREE CL IT Cooling TECHNICL DT GLIDER EVO FREE CL STNDRD OPTIONL LNO KIT 100% LNO KIT 85% LNO KIT 70% ELN KIT GLIDER EVO FREE CL Cooling capacity (1) Free-Cooling capacity (2) Evaporator water flow rate kpa Evaporator pressure drop Compressors Quantity n. Capacity control % xial fans n. ir circuits n. Refrigerant Total refrigerant charge (optional excluded) Gas circuits n. Power supply V/Ph/Hz Max unit operating current (FL) Unit starting current (LR) EER (1) / ESEER Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) Net weight Hydraulic connections Evaporator IN/OUT - OD (5) Ø mm Glycol free system (2) Free-Cooling capacity Glycol free water pump power input Partial heat recovery (6) Heating capacity Pumping group Power input Cooling capacity (1) Free-Cooling capacity (2) EER (1) / Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) Cooling capacity (1) Free-Cooling capacity (2) EER (1) / Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) Cooling capacity (1) Free-Cooling capacity (2) EER (1) / Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) Cooling capacity (1) Free-Cooling capacity (2) EER (1) / Sound power level [Lw] (3) verage sound pressure level [Lpm] (4) 960 V V V V V V V V2 F16 F16 F18 F20 F20 F20 F22 F ,9 358,1 379,7 394,2 418,8 442,5 465,4 488, ,0 205,0 218,0 230,0 244,0 258,0 270,0 284, twin-screw twin-screw twin-screw twin-screw twin-screw twin-screw twin-screw twin-screw % % % % % % % % R134a R134a R134a R134a R134a R134a R134a R134a /3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 716,5 737,5 787,7 837,9 893,6 949,2 993,1 1037,0 837,4 968,4 1040,2 1088,0 1243,0 1296,0 1415,8 1457,6 3,21 3,20 3,20 3,26 3,25 3,25 3,24 3,24 3,72 3,83 3,79 3,77 3,78 3,83 3,81 3,79 101,4 99,9 101,7 103,9 103,9 103,9 104,1 104,2 79,6 78,1 79,5 81,5 81,5 81,5 81,4 81, ,3 168,3 168,3 168,3 168,3 168,3 168,3 168, ,0 15,0 15,0 15,0 15,0 15,0 15,0 15,0 206,0 226,0 239,0 253,0 268,0 283,0 297,0 312,0 15,0 15,0 15,0 15,0 15,0 15,0 15,0 15, ,9 358,1 379,7 394,2 418,8 442,5 465,4 488, ,21 3,20 3,20 3,26 3,25 3,25 3,24 3,24 99,4 97,9 99,7 101,9 101,9 101,9 102,1 102,2 77,6 76,1 77,5 79,5 79,5 79,5 79,4 79, ,6 367,3 387,3 400,6 426,2 452,4 474,9 497, ,10 3,06 3,08 3,15 3,13 3,11 3,11 3,12 98,4 96,9 98,7 100,9 100,9 100,9 101,1 101,2 76,6 75,1 76,5 78,5 78,5 78,5 78,4 78, ,3 382,8 401,0 413,1 441,6 471,3 492,1 515, ,93 2,85 2,89 2,97 2,93 2,89 2,91 2,93 95,4 93,9 95,7 97,9 97,9 97,9 98,1 98,2 73,6 72,1 73,5 75,5 75,5 75,5 75,4 75, ,3 382,8 401,0 413,1 441,6 471,3 492,1 515, ,93 2,85 2,89 2,97 2,93 2,89 2,91 2,93 92,4 90,9 92,7 94,9 94,9 94,9 95,1 95,2 70,6 69,1 70,5 72,5 72,5 72,5 72,4 72,3 1. Referred to glycol solution temperature 15/10 C; 20% Ethylene glycol solution; air temperature to the condenser 35 C. Fouling factor of the exchangers 0,043 m² K/. 2. Referred to glycol solution inlet temperature 15 C; 20% Ethylene glycol solution; ambient temperature 3 C. Fouling factor of the exchangers 0,043 m² K/. 3. Sound power level [Lw] according to ISO EN verage sound pressure level [LPm] 1m far according to ISO EN Hydraulic connection with grooved end complete with flexible joint and adapter pipe for solder connection. 6. Referred to glycol solution temperature 15/10 C; 20% Ethylene glycol solution; air temperature to the condenser 35 C. Water temperature heat recovery 40/45 C 0% glycol solution; Fouling factor of the exchangers 0,043 m² K/. DIMENSIONS (mm) F a b c F F F F F F F F F b F a c 150 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

151 UNICO TURBO FL FREE UNICO TURBO FL FREE: Packaged air cooled liquid chillers with free-cooling system in class energy efficiency for outdoor installation, equipped with oil-free centrifugal compressors with magnetic levitation bearings, flooded evaporator, microchannel condensing coils and free-cooling coils. Cooling Capacity: Free-Cooling Capacity: FREECOOLING HIGHEFFICIENCY INVERTER CLSS LOWNOISE UNICO TURBO FL FREE rcgroupairconditioning CLSS INVERTER OIL FREE R134a FLOODED C MICRO CHNNEL FREE COOLING MIN FETURES ir cooled liquid chiller with free-cooling system in class energy efficiency. 15 models available, for a wide selection opportunity. verage step of 100. EER up to 3,60. ESEER up to 5,76. Oil-free centrifugal compressors with magnetic levitation bearings driven by built-in inverter. R134a Refrigerant charge. Single refrigerant circuit. C xial fans. Flooded evaporator. Microchannel condensing coils in aluminium. Electronic expansion valve. Single air circuit. Modular construction. Suitable for outdoor installation. MIN BENEFITS Up to four centrifugal compressors with magnetic levitation bearings on the refrigerant circuit for an high efficiency. No need of power factor correction. Minimum starting current (LR) Low refrigerant charge. Very high EER and ESEER. Class energy efficiency. Quiet operation. vailability of double refrigerant circuit version. vailability of kit for further reduction of the noise. vailability of EC fans for a higher efficiency. Microprocessor control system with 7 touch screen display. Extremely easily of maintenance. Complete set of components dedicated to the safety of the unity. INDIRECT FREE COOLING SYSTEM: Complete cooling of the chilled water of the existing cooling system with the outside air. The energy saving will be higher the longer the outside temperature remains below the required temperature for cooling. CLSS ENERGY EFFICIENCY: The best and most accurate components applied to the chillers. WORKING LIMITS IN COOLING MODE Chilled water outlet temperature: 5 15 C mbient temperature: C WORKING LIMITS IN FREE-COOLING MODE Minimum chilled water outlet temperature: 5 C Minimum ambient temperature: -20 C fiftycoolyears fiftycoolyears RCGROUP Sp G_ITC_RCW

152 UNICO TURBO FL FREE COMPONENTS FRMEWORK Base, self supporting frame and panelling in steel plate with protective surfaces treatment in compliance with UNI ISO 9227/STMB117 and ISO 7253, and painted with epoxy powders. Colour: RL 9002 textured. COMPRESSORS Twin-turbine centrifugal compressor, oil-free type, optimized for R134a refrigerant. The term oil-free refers to the total absence of lubricating oil within the compressor Magnetic levitation bearings. Manometric compression ratio: Stepless capacity control trough integrated inverter. High efficiency permanent-magnet synchronous motor with integrated Soft- Start system (starting current limited to 5). Power factor motor cosφ > 0.9 for a large part of the operating range. Motor and electronic power section cooling by liquid refrigerant injection into the integrated cooling circuit. Electric motor thermal protection via internal winding temperature sensors. Electronic integrated control for operation and alarms status. Sensor on refrigerant discharge for temperature monitoring. Inner sensors for electronic components and inverter temperature control. Security system to protect the crankshaft and magnetic bearings in the event of failure of power supply. Installation with walls sound attenuators. Degree of protection: IP54. Electric resistance of the suction pipe, together with activated antifreeze evaporator, to prevent the migration of refrigerant inside the compressor. EVPORTOR Flooded shell and tube evaporator, optimized for R134a refrigerant. Version two passes, characterized by low pressure losses on the water side. Water tubes with a helical rifled internal surface. Integrated liquid drop separator. Shell, header, tube sheets made of carbon steel, tubes in Cu. nticondensate insulation made of polyurethane. Large liquid level indicator. Temperature sensors on water inlet and outlet. Water flow switch for water flow control on water outlet towards the plant, not installed but supplied in kit. Large liquid level indicator ntifreeze heater. Hydraulic connections with grooved end supplied as standard with flexible joint and adapter pipe to be welded. CONDENSING COIL Microchannel condensing coil in aluminium perfectly suitable for the civil and industrial applications cooling, while the protection function of the oxide layer allows an optimum resistance to corrosion also in case of aggressive ambient conditions. Extremely light construction. The coil weight is only 50% compared to traditional copper pipes and aluminium fins of the same capacity. Low air side pressure drop and consequentially drastic reduction of the fans motors electric energy consumption. High heat exchange efficiency. Reduced internal volume capable of reducing the total refrigerant charge. t the same performances conditions, the micro-channels condensers require up-to less than 75% refrigerant when compared to the traditional heat exchangers. Single air circuit. Motorized valves for condenser partialization system. Frame in painted galvanized steel. IT Cooling FN SECTION xial fans with sickle-shaped blades, fan guard and optimized for low noise levels. External rotor C type electric motor with stepless variable speed for condensing pressure control. IP54 enclosure class. REFRIGERNT CIRCUIT Components for each refrigerant circuit: Capacitive level sensor connected to the driver of the expansion valve. Electronic expansion valve that allows high performance and system efficiency and for the refrigerant level control in the evaporator. By-pass valve for start-up. Electronic by-pass valve for compressor start. Non return valve on by-pass line for compressor start. Economizer for model 560 T2E, 810 T2E, 1070 T4E, 1120 T4E, 1200 T3E, 1500 T4E. The system includes: - Copper brazed plate type with cover plates, plates and connections in ISI 316 stainless steel. - nticondensate insulation made of polyurethane. - Intermediate electronic expansion valve. Sight glass. Filter dryer on liquid line. Service valve on liquid line. Service valve on gas suction and discharge. Non return valve on gas discharge. Safety valve on low pressure side. Safety valve on high pressure side. Pressure transducers with indication, control and protection functions, on low and high refrigerant pressure. High pressure safety switch with manual reset. Refrigerant circuit with copper tubing with anticondensate insulation of the suction line. Plastic capillary hoses for pressure sensors connection and cooling line of the compressor R134a refrigerant charge. ELECTRICL PNEL In accordance with EN norms, suitable for outdoor installation, complete with: Main switch with door lock safety. Fuses for each compressor. Magnetothermic switches for fans or water pumps (if scheduled). Contactors for each load. Transformer for auxiliary circuit and microprocessor supply. Panel with machine controls. Power supply 400/3/50. CONTROL SYSTEM Microprocessor system with Touch Screen graphic display for control and monitor of operating and alarms status. The system includes: - Voltage free contact for remote general alarm. - Voltage free contact for external alarm. The inlet is associable with refrigerant gas leak detector (optional accessory). - Main components hour-meter. - Recording of the last 24 occurred alarms. - Non-volatile Flash memory for data storage. - Menu with protection password. FREE-COOLING COIL Heat exchanger coil with copper tubes and high efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops. The combination of two factors, special tubes and fins, allow to optimally combine the following aspects: - Maximum capacity relative to the size of the exchanger. - Reduction of the air flow required for the heat exchange. Frame in galvanized steel. Motorized valves for free-cooling water circuit control. Intermediate free-cooling sensor. Temperature sensor on ambient air. 152 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

153 IT Cooling UNICO TURBO FL FREE OPTIONL CCESSORIES UNICO TURBO FL FREE LNO kit (noise reduction) ctive filters for containment of the harmonic distortion Rubber support (kit) 79 - Electrical panel heating system Double refrigerant circuit EC fan 350 -Kit TK PRO corrosion resistant painting treatment Free-cooling coils with pre-painted fins nalogic flowmeter Power supply analyzer Multimeter kit Refrigerant gas leak detector Data Logger RC-Com MBUS/JBUS Serial board LON Serial board BCnet Ethernet - SNMP - TCP/IP Serial board BCnet MS/TP Serial board Serial card for GSM Modem Kit modem GSM Plantwatch without modem Remote graphic terminal kit Master plant SEQUENCER RC CLOUD PLTFORM 410 T2 490 T2 560 T2E 680 T2 810 T2E 740 T3 820 T3 900 T T3E 980 T T4E VT4 VT4 VT5 VT6 VT7 VT6 VT7 VT8 VT10 VT8 VT UNICO TURBO FL FREE LNO kit (noise reduction) ctive filters for containment of the harmonic distortion Rubber support (kit) 79 - Electrical panel heating system Double refrigerant circuit EC fan 350 -Kit TK PRO corrosion resistant painting treatment Free-cooling coils with pre-painted fins nalogic flowmeter Power supply analyzer Multimeter kit Refrigerant gas leak detector Data Logger RC-Com MBUS/JBUS Serial board LON Serial board BCnet Ethernet - SNMP - TCP/IP Serial board BCnet MS/TP Serial board Serial card for GSM Modem Kit modem GSM Plantwatch without modem Remote graphic terminal kit Master plant SEQUENCER RC CLOUD PLTFORM 1120 T4E 1360 T T T4E VT10 VT11 VT12 VT12 - available accessory; - not available accessory fiftycoolyears RCGROUP Sp G_ITC_RCW

154 UNICO TURBO FL FREE IT Cooling TECHNICL DT UNICO TURBO FL FREE STNDRD LNO KIT 100% LNO KIT 85% LNO KIT 70% UNICO TURBO FL FREE Cooling capacity (1) Free-Cooling capacity (2) Total water flow rate (*) kpa Total pressure drop (*) Compressors Quantity n. Cooling capacity control % xial fans n. ir circuits n. Refrigerant Total refrigerant charge (optional excluded) Gas circuits n. Power supply V/Ph/Hz Max unit operating current (FL) Unit starting current (LR) EER (1) / ESEER Sound power level [Lw] (3) verage sound pressure level [LPm] (4) Net weight Hydraulic connections Evaporator IN/OUT - OD (5) Ø mm Cooling capacity (1) Free-Cooling capacity (2) EER (1) / Sound power level [Lw] (3) verage sound pressure level [LPm] (4) Cooling capacity (1) Free-Cooling capacity (2) EER (1) / Sound power level [Lw] (3) verage sound pressure level [LPm] (4) Cooling capacity (1) Free-Cooling capacity (2) EER (1) / Sound power level [Lw] (3) verage sound pressure level [LPm] (4) 410 T2 490 T2 560 T2E 680 T2 810 T2E 740 T3 820 T3 900 T3 VT4 VT4 VT5 VT6 VT7 VT6 VT7 VT ,7 153,6 177,7 219,0 263,0 215,4 253,3 261, ,9 91,3 107,0 128,0 152,0 138,0 153,0 166, centrifugal centrifugal centrifugal centrifugal centrifugal centrifugal centrifugal centrifugal % % % % % % % % R134a R134a R134a R134a R134a R134a R134a R134a /3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 316,2 316,2 324,4 490,1 498,3 474,3 482,5 727,0 41,2 41,2 49,0 56,8 61,8 64,6 69,6 77,4 3,60 3,32 3,36 3,27 3,24 3,58 3,38 3,56 5,07 5,05 5,15 5,35 5,47 5,34 5,03 5,23 94,8 94,8 95,6 96,4 97,0 96,5 97,1 97,8 74,8 74,8 75,1 75,4 75,6 75,5 75,7 76, ,3 168,3 168,3 168,3 168,3 168,3 168,3 168, ,7 153,6 177,7 219,0 263,0 215,4 253,3 261, ,60 3,32 3,36 3,27 3,24 3,58 3,38 3,56 93,7 93,7 94,5 95,3 95,9 95,4 96,0 96,7 73,7 73,7 74,0 74,3 74,5 74,4 74,6 75, ,9 151,3 172,4 211,5 263,1 227,8 247,9 266, ,55 3,20 3,26 3,23 3,06 3,38 3,28 3,32 92,6 92,6 93,4 94,2 94,8 94,3 94,9 95,6 72,6 72,6 72,9 73,2 73,4 73,3 73,5 73, ,8 142,0 162,5 195,0 233,2 216,1 233,4 249, ,46 3,14 3,20 3,21 3,16 3,30 3,23 3,19 90,9 90,9 91,7 92,5 93,1 92,6 93,2 93,9 70,9 70,9 71,2 71,5 71,7 71,6 71,8 72,2 1. Referred to glycol solution temperature 15/10 C; 20% Ethylene glycol solution; ambient temperature 35 C. Fouling factor of the exchangers 0,043 m² K/. 2. Referred to glycol solution inlet temperature 15 C; 20% Ethylene glycol solution; ambient temperature 3 C. Fouling factor of the exchangers 0,043 m² K/. 3. Sound power level [Lw] according to ISO EN verage sound pressure level [LPm] 1m far according to ISO EN Hydraulic connection with grooved end, supplied as standard with flexible joint and adapter pipe. (*) Referred to the entire unit: evaporator + free-cooling system. 154 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

155 IT Cooling TECHNICL DT UNICO TURBO FL FREE STNDRD LNO KIT 100% LNO KIT 85% LNO KIT 70% UNICO TURBO FL FREE Cooling capacity (1) Free-Cooling capacity (2) Total water flow rate (*) kpa Total pressure drop (*) Compressors Quantity n. Cooling capacity control % xial fans n. ir circuits n. Refrigerant Total refrigerant charge (optional excluded) Gas circuits n. Power supply V/Ph/Hz Max unit operating current (FL) Unit starting current (LR) EER (1) / ESEER Sound power level [Lw] (3) verage sound pressure level [LPm] (4) Net weight Hydraulic connections Evaporator IN/OUT - OD (5) Ø mm Cooling capacity (1) Free-Cooling capacity (2) EER (1) / Sound power level [Lw] (3) verage sound pressure level [LPm] (4) Cooling capacity (1) Free-Cooling capacity (2) EER (1) / Sound power level [Lw] (3) verage sound pressure level [LPm] (4) Cooling capacity (1) Free-Cooling capacity (2) EER (1) / Sound power level [Lw] (3) verage sound pressure level [LPm] (4) UNICO TURBO FL FREE 1200 T3E 980 T T4E 1120 T4E 1360 T T T4E VT10 VT8 VT9 VT10 VT11 VT12 VT ,4 308,5 337,8 351,2 438,3 426,1 463, ,0 183,0 201,0 214,0 256,0 260,0 277, centrifugal centrifugal centrifugal centrifugal centrifugal centrifugal centrifugal % % % % % % % R134a R134a R134a R134a R134a R134a R134a /3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 743,4 632,5 640,7 648,9 972,0 980,2 980,2 82,4 90,2 98,0 93,0 105,8 113,6 113,6 3,23 3,31 3,33 3,40 3,26 3,41 3,34 5,35 5,20 5,27 5,31 5,56 5,76 5,60 98,6 97,8 98,2 98,6 99,1 99,5 99,5 76,2 76,1 76,1 76,2 76,4 76,5 76, ,1 219,1 219,1 219,1 219,1 219,1 219, ,4 308,5 337,8 351,2 438,3 421,1 463, ,23 3,31 3,33 3,40 3,26 3,46 3,34 97,5 96,7 97,1 97,5 98,0 98,4 98,4 75,1 75,0 75,0 75,1 75,3 75,4 75, ,0 302,8 332,5 340,0 423,4 412,6 454, ,08 3,19 3,20 3,30 3,21 3,34 3,23 96,4 95,6 96,0 96,4 96,9 97,3 97,3 74,0 73,9 73,9 74,0 74,2 74,3 74, ,9 284,1 310,8 319,1 376,7 381,1 446, ,11 3,14 3,14 3,25 3,30 3,34 2,98 94,7 93,9 94,3 94,7 95,2 95,6 95,6 72,3 72,2 72,2 72,3 72,5 72,6 72,6 1. Referred to glycol solution temperature 15/10 C; 20% Ethylene glycol solution; ambient temperature 35 C. Fouling factor of the exchangers 0,043 m² K/. 2. Referred to glycol solution inlet temperature 15 C; 20% Ethylene glycol solution; ambient temperature 3 C. Fouling factor of the exchangers 0,043 m² K/. 3. Sound power level [Lw] according to ISO EN verage sound pressure level [LPm] 1m far according to ISO EN Hydraulic connection with grooved end, supplied as standard with flexible joint and adapter pipe. (*) Referred to the entire unit: evaporator + free-cooling system fiftycoolyears RCGROUP Sp G_ITC_RCW

156 UNICO TURBO FL FREE IT Cooling DIMENSIONS (mm) VT a b c VT VT VT VT VT VT VT VT VT c b a 156 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

157 UNICO TURBO FLG FREE UNICO TURBO FLG FREE: Packaged air cooled liquid chillers with free-cooling system in class energy efficiency for outdoor installation, equipped with oil-free centrifugal compressors with magnetic levitation bearings, flooded evaporator, microchannel condensing coils and free-cooling coils. Cooling Capacity: Free-Cooling Capacity: HFO1234ze GOGREENN solution UNICO TURBO FLG FREE rcgroupairconditioning CLSS INVERTER OIL FREE 1234ze C HIGHEFFICIENCY FLOODED FREECOOLING INVERTER CLSS MICRO CHNNEL LOWNOISE LOWGWP FREE COOLING MIN FETURES ir cooled liquid chiller with free-cooling system in class energy efficiency. 9 models, 2 versions available for a wide selection opportunity. verage step of 100. EER up to 3,50. ESEER up to 5,60. Oil-free centrifugal compressors with magnetic levitation bearings driven by built-in inverter. HFO1234ze refrigerant charge, LOW GWP, GWP < 6. Single refrigerant circuit. EC xial fans. Flooded evaporator. Microchannel condensing coils in aluminium. Electronic expansion valve. Single air circuit. Modular construction. Suitable for outdoor installation. MIN BENEFITS Up to four centrifugal compressors with magnetic levitation bearings on the refrigerant circuit for an high efficiency. No need of power factor correction. Minimum starting current (LR) Low refrigerant charge. Very high EER and ESEER. Class energy efficiency. Quiet operation. vailability of double refrigerant circuit version. vailability of kit for further reduction of the noise. Microprocessor control system with 7 touch screen display. Extremely easily of maintenance. Complete set of components dedicated to the safety of the unity. INDIRECT FREE COOLING SYSTEM: Complete cooling of the chilled water of the existing cooling system with the outside air. The energy saving will be higher the longer the outside temperature remains below the required temperature for cooling. CLSS ENERGY EFFICIENCY: The best and most accurate components applied to the chillers. WORKING LIMITS IN COOLING MODE Chilled water outlet temperature: 5 15 C mbient temperature: C WORKING LIMITS IN FREE-COOLING MODE Minimum chilled water outlet temperature: 5 C Minimum ambient temperature: -20 C fiftycoolyears fiftycoolyears RCGROUP Sp G_ITC_RCW

158 UNICO TURBO FLG FREE GOGREEN solutions IT Cooling COMPONENTS FRMEWORK Base, self supporting frame and panelling in steel plate with protective surfaces treatment in compliance with UNI ISO 9227/STMB117 and ISO 7253, and painted with epoxy powders. Colour: RL 9002 textured. COMPRESSORS Twin-turbine centrifugal compressor, oil-free type, optimized for HFO1234ze refrigerant. The term oil-free refers to the total absence of lubricating oil within the compressor Magnetic levitation bearings. Manometric compression ratio: Stepless capacity control trough integrated inverter. High efficiency permanent-magnet synchronous motor with integrated Soft- Start system (starting current limited to 5). Power factor motor cosφ > 0.9 for a large part of the operating range. Motor and electronic power section cooling by liquid refrigerant injection into the integrated cooling circuit. Electric motor thermal protection via internal winding temperature sensors. Electronic integrated control for operation and alarms status. Sensor on refrigerant discharge for temperature monitoring. Inner sensors for electronic components and inverter temperature control. Security system to protect the crankshaft and magnetic bearings in the event of failure of power supply. Installation with walls sound attenuators. Degree of protection: IP54. Electric resistance of the suction pipe, together with activated antifreeze evaporator, to prevent the migration of refrigerant inside the compressor. EVPORTOR Flooded shell and tube evaporator, optimized for HFO1234ze refrigerant. Version two passes, characterized by low pressure losses on the water side. Water tubes with a helical rifled internal surface. Integrated liquid drop separator. Shell, header, tube sheets made of carbon steel, tubes in Cu. nticondensate insulation made of polyurethane. Large liquid level indicator. Temperature sensors on water inlet and outlet. Water flow switch for water flow control on water outlet towards the plant, not installed but supplied in kit. Large liquid level indicator ntifreeze heater. Hydraulic connections with grooved end supplied as standard with flexible joint and adapter pipe to be welded. CONDENSING COIL Microchannel condensing coil in aluminium perfectly suitable for the civil and industrial applications cooling, while the protection function of the oxide layer allows an optimum resistance to corrosion also in case of aggressive ambient conditions. Extremely light construction. The coil weight is only 50% compared to traditional copper pipes and aluminium fins of the same capacity. Low air side pressure drop and consequentially drastic reduction of the fans motors electric energy consumption. High heat exchange efficiency. Reduced internal volume capable of reducing the total refrigerant charge. t the same performances conditions, the micro-channels condensers require up-to less than 75% refrigerant when compared to the traditional heat exchangers. Single air circuit. Motorized valves for condenser partialization system. Frame in painted galvanized steel. FN SECTION xial fans with sickle-shaped blades and fan guard optimized for low noise levels designed with bionical know how. Optimized diffusor with static blades. External rotor EC type electric motor with stepless variable speed for condensing pressure control. IP54 enclosure class. REFRIGERNT CIRCUIT Components for each refrigerant circuit: Capacitive level sensor connected to the driver of the expansion valve. Electronic expansion valve that allows high performance and system efficiency and for the refrigerant level control in the evaporator. By-pass valve for start-up. Electronic by-pass valve for compressor start. Non return valve on by-pass line for compressor start. Economizer for models 520 T2E, 620 T2E, 780 T3E, 900 T3E, 1040 T4E, 1200 T4E, 1300 T4E. The system includes: - Copper brazed plate type with cover plates, plates and connections in ISI 316 stainless steel. - nticondensate insulation made of polyurethane. - Intermediate electronic expansion valve. Sight glass. Filter dryer on liquid line. Service valve on liquid line. Service valve on gas suction and discharge. Non return valve on gas discharge. Safety valve on low pressure side. Safety valve on high pressure side. Pressure transducers with indication, control and protection functions, on low and high refrigerant pressure. High pressure safety switch with manual reset. Refrigerant circuit with copper tubing with anticondensate insulation of the suction line. Plastic capillary hoses for pressure sensors connection and cooling line of the compressor HFO1234ze refrigerant charge. ELECTRICL PNEL In accordance with EN norms, suitable for outdoor installation, complete with: Main switch with door lock safety. Fuses for each compressor. Magnetothermic switches for fans or water pumps (if scheduled). Contactors for each load. Transformer for auxiliary circuit and microprocessor supply. Panel with machine controls. Power supply 400/3/50. CONTROL SYSTEM Microprocessor system with Touch Screen graphic display for control and monitor of operating and alarms status. The system includes: - Voltage free contact for remote general alarm. - Voltage free contact for external alarm. The inlet is associable with refrigerant gas leak detector (optional accessory). - Main components hour-meter. - Recording of the last 24 occurred alarms. - Non-volatile Flash memory for data storage. - Menu with protection password. FREE-COOLING COIL Heat exchanger coil with copper tubes and high efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops. The combination of two factors, special tubes and fins, allow to optimally combine the following aspects: - Maximum capacity relative to the size of the exchanger. - Reduction of the air flow required for the heat exchange. Frame in galvanized steel. Motorized valves for free-cooling water circuit control. Intermediate free-cooling sensor. Temperature sensor on ambient air. 158 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

159 IT Cooling OPTIONL CCESSORIES GOGREEN solutions UNICO TURBO FLG FREE UNICO TURBO FLG FREE LNO kit (noise reduction) ctive filters for containment of the harmonic distortion Rubber support (kit) 79 - Electrical panel heating system Double refrigerant circuit 350 -Kit TK PRO corrosion resistant painting treatment Free-cooling coils with pre-painted fins nalogic flowmeter Power supply analyzer Multimeter kit Refrigerant gas leak detector Data Logger RC-Com MBUS/JBUS Serial board LON Serial board BCnet Ethernet - SNMP - TCP/IP Serial board BCnet MS/TP Serial board Serial card for GSM Modem Kit modem GSM Plantwatch without modem Remote graphic terminal kit Master plant SEQUENCER RC CLOUD PLTFORM 400 T2 520 T2E 620 T2E 700 T3 780 T3E 900 T3E 1040 T4E 1200 T4E 1300 T4E VT4 VT5 VT6 VT7 VT7 VT8 VT9 VT11 VT available accessory; - not available accessory fiftycoolyears RCGROUP Sp G_ITC_RCW

160 UNICO TURBO FLG FREE GOGREEN solutions IT Cooling TECHNICL DT UNICO TURBO FLG FREE STNDRD UNICO TURBO FLG FREE Cooling capacity (1) Free-Cooling capacity (2) Total water flow rate (*) kpa Total pressure drop (*) Compressors Quantity n. Cooling capacity control (6) % xial fans n. ir circuits n. Refrigerant Total refrigerant charge (optional excluded) Gas circuits n. Power supply V/Ph/Hz Max unit operating current (FL) Unit starting current (LR) EER (1) / ESEER Sound power level [Lw] (3) verage sound pressure level [LPm] (4) Net weight Hydraulic connections Evaporator IN/OUT - OD (5) Ø mm 400 T2 520 T2E 620 T2E 700 T3 780 T3E 900 T3E 1040 T4E 1200 T4E 1300 T4E VT4 VT5 VT6 VT7 VT7 VT8 VT9 VT11 VT ,8 146,3 179,5 206,6 221,6 261,6 297,0 342,3 364, ,5 95,5 113,9 128,6 143,3 165,3 191,1 220,4 231, centrifugal centrifugal centrifugal centrifugal centrifugal centrifugal centrifugal centrifugal centrifugal %...100% 14%...100% 14%...100% 10%...100% 10%...100% 10%...100% 7%...100% 7%...100% 7%...100% HFO1234ze HFO1234ze HFO1234ze HFO1234ze HFO1234ze HFO1234ze HFO1234ze HFO1234ze HFO1234ze /3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/ ,20 3,50 3,39 3,34 3,47 3,38 3,44 3,43 3,38 4,62 5,07 5,52 4,83 5,12 5,51 5,07 5,43 5,60 94,8 95,6 96,4 97,1 97,1 97,8 98,2 99,1 99,5 74,8 75,1 75,4 75,7 75,7 76,1 76,1 76,4 76, ,3 168,3 168,3 168,3 168,3 168,3 219,1 219,1 219,1 1. Referred to glycol solution temperature 15/10 C; 20% Ethylene glycol solution; ambient temperature 35 C. Fouling factor of the exchangers 0,018 m² K/. 2. Referred to glycol solution inlet temperature 15 C; 20% Ethylene glycol solution; ambient temperature 0 C. Fouling factor of the exchangers 0,018 m² K/. 3. Sound power level [Lw] according to ISO EN verage sound pressure level [LPm] 1m far according to ISO EN Hydraulic connection with grooved end, supplied as standard with flexible joint and adapter pipe. 6. Referred to ambient air temperature at 18 C. (*) Referred to the entire unit: evaporator + free-cooling system. DIMENSIONS (mm) VT a b c VT VT VT VT VT VT VT VT c b a 160 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

161 UNICO TURBO FL UNICO TURBO FL: Packaged air cooled liquid chillers in class energy efficiency for outdoor installation, equipped with oil-free centrifugal compressors with magnetic levitation bearings, flooded evaporator and microchannel condensing coils. Cooling Capacity: HIGHEFFICIENCY INVERTER CLSS LOWNOISE UNICO TURBO FL rcgroupairconditioning MIN FETURES ir cooled liquid chiller in class energy efficiency. 17 models, 2 versions available for a wide selection opportunity. verage step of 70. EER up to 3,48. ESEER up to 5,88. Oil-free centrifugal compressors with magnetic levitation bearings driven by built-in inverter. R134a Refrigerant charge. Single refrigerant circuit. C xial fans. Flooded evaporator. Microchannel condensing coils in aluminium. Electronic expansion valve. Single air circuit. Modular construction. Suitable for outdoor installation. MIN BENEFITS Up to four centrifugal compressors with magnetic levitation bearings on the refrigerant circuit for an high efficiency. No need of power factor correction. Minimum starting current (LR) Low refrigerant charge. Very high EER and ESEER. Class energy efficiency. Quiet operation. vailability of double refrigerant circuit version. vailability of kit for further reduction of the noise. vailability of EC fans for a higher efficiency. vailability of pumping groups fiftycoolyears fiftycoolyears RCGROUP Sp G_ITC_RCW CLSS INVERTER OIL FREE R134a FLOODED C MICRO CHNNEL Microprocessor control system with 7 touch screen display. Extremely easily of maintenance. Complete set of components dedicated to the safety of the unity. Eurovent Certification. MGNETIC LEVITTION CENTRIFUGL COMPRESSOR The TURBO FL liquid chillers are equipped with two-stage centrifugal compressor with variable speed, which is able to follow punctually plant demands, obtaining values of energy efficiency ratio (EER) growing in a narrowing of the cooling load. The compressors are equipped with magnetic levitation oil-free bearings which compared to traditional ball bearings, completely eliminate all the maintenance procedures of lubrication. CLSS ENERGY EFFICIENCY The best and most accurate components applied to the chillers. WORKING LIMITS IN COOLING MODE Chilled water outlet temperature: 4 15 C mbient temperature: C

162 UNICO TURBO FL COMPONENTS FRMEWORK Base, self supporting frame and panelling in steel plate with protective surfaces treatment in compliance with UNI ISO 9227/STMB117 and ISO 7253, and painted with epoxy powders. Colour: RL COMPRESSORS Twin-turbine centrifugal compressor, oil-free type, optimized for R134a refrigerant. The term oil-free refers to the total absence of lubricating oil within the compressor. Magnetic levitation bearings. Manometric compression ratio: Stepless capacity control trough integrated inverter. High efficiency permanent-magnet synchronous motor with integrated Soft- Start system (starting current limited to 5). Power factor motor cos φ > 0.9 for a large part of the operating range. Motor and electronic power section cooling by liquid refrigerant injection into the integrated cooling circuit. Electric motor thermal protection via internal winding temperature sensors. Electronic integrated control for operation and alarms status. Sensor on refrigerant discharge for temperature monitoring. Inner sensors for electronic components and inverter temperature control. Security system to protect the crankshaft and magnetic bearings in the event of failure of power supply. Installation with walls sound attenuators. Degree of protection: IP54. Electric resistance of the suction pipe, together with activated antifreeze evaporator, to prevent the migration of refrigerant inside the compressor. EVPORTOR Flooded shell and tube evaporator, optimized for R134a refrigerant. Version two passes, characterized by low pressure losses on the water side. Water tubes with a helical rifled internal surface. Integrated liquid drop separator. Shell, header, tube sheets made of carbon steel, tubes in Cu. nticondensate insulation made of polyurethane. Large liquid level indicator. Temperature sensors on water inlet and outlet. Water flow switch for water flow control on water outlet towards the plant, not installed but supplied in kit. Large liquid level indicator ntifreeze heater. Hydraulic connections with grooved end supplied as standard with flexible joint and adapter pipe to be welded. CONDENSING COIL Microchannel condensing coil in aluminium, perfectly suitable for the civil and industrial applications cooling, while the protection function of the oxide layer allows an optimum resistance to corrosion also in case of aggressive ambient conditions. Extremely light construction. The coil weight is only 50% compared to traditional copper pipes and aluminium fins of the same capacity. Low air side pressure drop and consequentially drastic reduction of the fans motors electric energy consumption. High heat exchange efficiency. Reduced internal volume capable of reducing the total refrigerant charge. t the same performances conditions, the micro-channels condensers require up-to less than 75% refrigerant when compared to the traditional heat exchangers. Single air circuit. Frame in painted galvanized steel. IT Cooling REFRIGERNT CIRCUIT Components for each refrigerant circuit: Capacitive level sensor connected to the driver of the expansion valve. Electronic expansion valve that allows high performance and system efficiency and for the refrigerant level control in the evaporator. By-pass valve for start-up. Non return valve on by-pass line for compressor start. Economizer for model 280 T1E, 560 T2E, 810 T2E, 1070 T4E, 1120 T4E, 1200 T3E, 1500 T4E. The system includes: - Copper brazed plate type with cover plates, plates and connections in ISI 316 stainless steel. - nticondensate insulation made of polyurethane. - Intermediate electronic expansion valve. Sight glass. Filter dryer on liquid line. Service valve on liquid line. Service valve on gas suction and discharge. Non return valve on gas discharge. Safety valve on low pressure side. Safety valve on high pressure side. Pressure transducers with indication, control and protection functions, on low and high refrigerant pressure. High pressure safety switch with manual reset. Refrigerant circuit with copper tubing with anticondensate insulation of the suction line. Plastic capillary hoses for pressure sensors connection and cooling line of the compressor R134a refrigerant charge. ELECTRICL PNEL In accordance with EN norms, suitable for outdoor installation, complete with: Main switch with door lock safety. Fuses for each compressor. Magnetothermic switches for fans or water pumps (if scheduled). Contactors for each load. Transformer for auxiliary circuit and microprocessor supply. Panel with machine controls. Power supply 400/3/50. CONTROL SYSTEM Microprocessor system with Touch Screen graphic display for control and monitor of operating and alarms status. The system includes: - Voltage free contact for remote general alarm. - Voltage free contact for external alarm. The inlet is associable with refrigerant gas leak detector (optional accessory). - Main components hour-meter. - Recording of the last 24 occurred alarms. - Non-volatile Flash memory for data storage. - Menu with protection password. FNS SECTION xial fans with sickle-shaped blades, fan guard and optimized for low noise levels. External rotor C type electric motor with stepless variable speed for condensing pressure control. IP54 enclosure class. 162 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

163 IT Cooling UNICO TURBO FL OPTIONL CCESSORIES UNICO TURBO FL Pumping group (1 pump) Pumping group (1+1stby) Pumping group (2 pumps) Pumping group (2+1stby) Pumping group LN (1 pump) Pumping group LN (1+1stby) Pumping group LN (2 pumps) Pumping group LN (2+1stby) LNO kit (noise reduction) ctive filters for containment of the harmonic distortion Rubber support (kit) Condenser partialization system 79 - Electrical panel heating system Double refrigerant circuit EC fan 350 -Kit TK PRO corrosion resistant painting treatment nalogic flowmeter Power supply analyzer Multimeter kit Refrigerant gas leak detector Data Logger RC-Com MBUS/JBUS Serial board LON Serial board BCnet Ethernet - SNMP - TCP/IP Serial board BCnet MS/TP Serial board Serial card for GSM Modem Kit modem GSM Plantwatch without modem Remote graphic terminal kit Master plant SEQUENCER RC CLOUD PLTFORM 280 T1E 340 T1 410 T2 490 T2 560 T2E 680 T2 810 T2E 740 T3 820 T3 900 T T3E VT3 VT3 VT4 VT4 VT5 VT6 VT7 VT6 VT7 VT8 VT UNICO TURBO FL Pumping group (1 pump) Pumping group (1+1stby) Pumping group (2 pumps) Pumping group (2+1stby) Pumping group LN (1 pump) Pumping group LN (1+1stby) Pumping group LN (2 pumps) Pumping group LN (2+1stby) LNO kit (noise reduction) ctive filters for containment of the harmonic distortion Rubber support (kit) Condenser partialization system 79 - Electrical panel heating system Double refrigerant circuit EC fan 350 -Kit TK PRO corrosion resistant painting treatment nalogic flowmeter Power supply analyzer Multimeter kit Refrigerant gas leak detector Data Logger RC-Com MBUS/JBUS Serial board LON Serial board BCnet Ethernet - SNMP - TCP/IP Serial board BCnet MS/TP Serial board Serial card for GSM Modem Kit modem GSM Plantwatch without modem Remote graphic terminal kit Master plant SEQUENCER RC CLOUD PLTFORM 980 T T4E 1120 T4E 1360 T T T4E VT8 VT9 VT10 VT11 VT12 VT available accessory; - not available accessory fiftycoolyears RCGROUP Sp G_ITC_RCW

164 UNICO TURBO FL IT Cooling TECHNICL DT UNICO TURBO FL STNDRD OPT LNO KIT 100% LNO KIT 85% LNO KIT 70% UNICO TURBO FL Cooling capacity (1) Evaporator water flow rate kpa Evaporator pressure drop Compressors Quantity n. Cooling capacity control % xial fans n. ir circuits n. Refrigerant Total refrigerant charge (optional excluded) Gas circuits n. Power supply V/Ph/Hz Max unit operating current (FL) Unit starting current (LR) EER (1) / ESEER Sound power level [Lw] (2) verage sound pressure level [LPm] (3) Net weight Hydraulic connections Evaporator IN/OUT - OD (4) Ø mm Pumping group 2 poles motor - Power input 4 poles motor - Power input Cooling capacity (1) EER (1) Sound power level [Lw] (2) verage sound pressure level [LPm] (3) Cooling capacity (1) EER (1) Sound power level [Lw] (2) verage sound pressure level [LPm] (3) Cooling capacity (1) EER (1) Sound power level [Lw] (2) verage sound pressure level [LPm] (3) / / / 280 T1E 340 T1 410 T2 490 T2 560 T2E 680 T2 810 T2E 740 T3 VT3 VT3 VT4 VT4 VT5 VT6 VT7 VT ,2 99,7 121,3 152,2 171,3 204,2 252,3 212,6 48,2 58,5 70,5 84,3 96,3 117,0 139,0 127, centrifugal centrifugal centrifugal centrifugal centrifugal centrifugal centrifugal centrifugal % % % % % % % % R134a R134a R134a R134a R134a R134a R134a R134a /3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 166,3 245,1 316,3 316,3 324,5 490,1 498,3 474,4 28,4 28,4 41,2 41,2 49,0 56,8 64,6 61,8 3,45 3,41 3,38 3,22 3,27 3,33 3,21 3,48 4,95 5,38 5,10 5,32 5,39 5,29 5,51 5,88 93,3 93,4 94,8 94,8 95,6 96,4 97,0 96,5 73,8 73,9 74,8 74,8 75,1 75,4 75,6 75, ,3 114,3 168,3 168,3 168,3 168,3 168,3 168, ,5 5,5 5,5 11,0 11,0 11, ,5 5,5 5,5 5,5 11,0 11, ,2 99,7 121,3 152,2 171,3 204,2 252,3 212, ,45 3,41 3,38 3,22 3,27 3,33 3,21 3,48 92,2 92,3 93,7 93,7 94,5 95,3 95,9 95,4 72,7 72,8 73,7 73,7 74,0 74,3 74,5 74, ,0 90,3 118,4 139,6 156,0 186,8 228,4 204, ,62 3,59 3,21 3,33 3,41 3,48 3,35 3,62 91,1 91,2 92,6 92,6 93,4 94,2 94,8 94,3 71,6 71,7 72,6 72,6 72,9 73,2 73,4 73, ,6 80,9 110,5 125,2 140,2 166,2 203,4 184, ,80 3,71 3,33 3,45 3,53 3,61 3,48 3,74 89,4 89,5 90,9 90,9 91,7 92,5 93,1 92,6 69,9 70,0 70,9 70,9 71,2 71,5 71,7 71,6 1. Referred to chilled water temperature 12/7 C 0% glycol solution; air temperature to the condenser 35 C. Fouling factor of the exchangers 0,043 m² K/. 2. Sound power level [Lw] according to ISO EN verage sound pressure level [LPm] 1m far according to ISO EN Hydraulic connection with grooved end, supplied as standard with flexible joint and adapter pipe. 164 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

165 IT Cooling UNICO TURBO FL TECHNICL DT UNICO TURBO FL STNDRD OPT LNO KIT 100% LNO KIT 85% LNO KIT 70% UNICO TURBO FL Cooling capacity (1) Evaporator water flow rate kpa Evaporator pressure drop Compressors Quantity n. Cooling capacity control % xial fans n. ir circuits n. Refrigerant Total refrigerant charge (optional excluded) Gas circuits n. Power supply V/Ph/Hz Max unit operating current (FL) Unit starting current (LR) EER (1) / ESEER Sound power level [Lw] (2) verage sound pressure level [LPm] (3) Net weight Hydraulic connections Evaporator IN/OUT - OD (4) Ø mm Pumping group 2 poles motor - Power input 4 poles motor - Power input Cooling capacity (1) EER (1) Sound power level [Lw] (2) verage sound pressure level [LPm] (3) Cooling capacity (1) EER (1) Sound power level [Lw] (2) verage sound pressure level [LPm] (3) Cooling capacity (1) EER (1) Sound power level [Lw] (2) verage sound pressure level [LPm] (3) / / / 820 T3 900 T T3E 980 T T4E 1120 T4E 1360 T T T4E VT7 VT8 VT10 VT8 VT9 VT10 VT11 VT12 VT ,8 262,4 376,2 305,3 329,2 341,5 415,9 408,3 461,5 141,0 155,0 206,0 169,0 184,0 193,0 234,0 237,0 258, centrifugal centrifugal centrifugal centrifugal centrifugal centrifugal centrifugal centrifugal centrifugal % % % % % % % % % R134a R134a R134a R134a R134a R134a R134a R134a R134a /3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 482,6 727,0 743,4 632,5 640,7 648,9 972,1 980,3 980,3 69,6 77,4 93,0 82,4 90,2 98,0 105,8 113,6 113,6 3,27 3,43 3,19 3,21 3,25 3,28 3,27 3,38 3,25 5,17 5,62 5,65 5,41 5,32 5,39 5,29 5,56 5,58 97,1 97,8 98,6 97,8 98,2 98,6 99,1 99,5 99,5 75,7 76,1 76,2 76,1 76,1 76,2 76,4 76,5 76, ,3 168,3 219,1 219,1 219,1 219,1 219,1 219,1 219,1 11,0 11,0 22,0 11,0 22,0 22,0 22,0 22,0 22,0 11,0 11,0 15,0 11,0 11,0 15,0 15,0 15,0 15, ,8 262,4 376,2 305,3 329,2 341,5 415,9 408,3 461, ,27 3,43 3,19 3,21 3,25 3,28 3,27 3,38 3,25 96,0 96,7 97,5 96,7 97,1 97,5 98,0 98,4 98,4 74,6 75,0 75,1 75,0 75,0 75,1 75,3 75,4 75, ,4 238,9 340,2 279,8 299,7 311,4 377,6 370,3 419, ,40 3,55 3,33 3,32 3,37 3,41 3,43 3,54 3,35 94,9 95,6 96,4 95,6 96,0 96,4 96,9 97,3 97,3 73,5 73,9 74,0 73,9 73,9 74,0 74,2 74,3 74, ,5 213,4 301,7 250,9 267,0 278,8 335,0 329,9 370, ,52 3,59 3,45 3,44 3,49 3,54 3,57 3,68 3,45 93,2 93,9 94,7 93,9 94,3 94,7 95,2 95,6 95,6 71,8 72,2 72,3 72,2 72,2 72,3 72,5 72,6 72,6 1. Referred to chilled water temperature 12/7 C 0% glycol solution; air temperature to the condenser 35 C. Fouling factor of the exchangers 0,043 m² K/. 2. Sound power level [Lw] according to ISO EN verage sound pressure level [LPm] 1m far according to ISO EN Hydraulic connection with grooved end, supplied as standard with flexible joint and adapter pipe fiftycoolyears RCGROUP Sp G_ITC_RCW

166 UNICO TURBO FL IT Cooling DIMENSIONS (mm) VT a b c VT VT VT VT VT VT VT VT VT VT c b a 166 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

167 UNICO TURBO FLG UNICO TURBO FLG: Packaged air cooled liquid chillers in class energy efficiency for outdoor installation, equipped with oil-free centrifugal compressors with magnetic levitation bearings, flooded evaporator and microchannel condensing coils. Cooling Capacity: HFO1234ze HIGHEFFICIENCY GOGREEN solutions UNICO TURBO FLG rcgroupairconditioning CLSS INVERTER OIL FREE 1234ze C INVERTER FLOODED CLSS LOWNOISE LOWGWP MICRO CHNNEL MIN FETURES ir cooled liquid chiller in class energy efficiency. 11 models available, for a wide selection opportunity. verage step of 100. EER up to 3,36. ESEER up to 5,94. Oil-free centrifugal compressors with magnetic levitation bearings driven by built-in inverter. HFO1234ze refrigerant charge, LOW GWP, GWP < 6. Single refrigerant circuit. EC xial fans with optimized diffusor. Flooded evaporator. Microchannel condensing coils in aluminium. Electronic expansion valve. Single air circuit. Modular construction. Suitable for outdoor installation. MIN BENEFITS Up to four centrifugal compressors with magnetic levitation bearings on the refrigerant circuit for an high efficiency. No need of power factor correction. Minimum starting current (LR) Low refrigerant charge. Very high EER and ESEER. Class energy efficiency. Quiet operation. vailability of double refrigerant circuit version. vailability of kit for further reduction of the noise. vailability of pumping groups. Microprocessor control system with 7 touch screen display. Extremely easily of maintenance. Complete set of components dedicated to the safety of the unity. MGNETIC LEVITTION CENTRIFUGL COMPRESSOR The TURBO FL liquid chillers are equipped with two-stage centrifugal compressor with variable speed, which is able to follow punctually plant demands, obtaining values of energy efficiency ratio (EER) growing in a narrowing of the cooling load. The compressors are equipped with magnetic levitation oil-free bearings which compared to traditional ball bearings, completely eliminate all the maintenance procedures of lubrication. CLSS ENERGY EFFICIENCY The best and most accurate components applied to the chillers. WORKING LIMITS IN COOLING MODE Chilled water outlet temperature: 4 15 C mbient temperature: C fiftycoolyears fiftycoolyears RCGROUP Sp G_ITC_RCW

168 UNICO TURBO FLG GOGREEN solutions IT Cooling COMPONENTS FRMEWORK Base, self supporting frame and panelling in steel plate with protective surfaces treatment in compliance with UNI ISO 9227/STMB117 and ISO 7253, and painted with epoxy powders. Colour: RL COMPRESSORS Twin-turbine centrifugal compressor, oil-free type, optimized for HFO1234ze refrigerant. The term oil-free refers to the total absence of lubricating oil within the compressor. Magnetic levitation bearings. Manometric compression ratio: Stepless capacity control trough integrated inverter. High efficiency permanent-magnet synchronous motor with integrated Soft- Start system (starting current limited to 5). Power factor motor cos φ > 0.9 for a large part of the operating range. Motor and electronic power section cooling by liquid refrigerant injection into the integrated cooling circuit. Electric motor thermal protection via internal winding temperature sensors. Electronic integrated control for operation and alarms status. Sensor on refrigerant discharge for temperature monitoring. Inner sensors for electronic components and inverter temperature control. Security system to protect the crankshaft and magnetic bearings in the event of failure of power supply. Installation with walls sound attenuators. Degree of protection: IP54. Electric resistance of the suction pipe, together with activated antifreeze evaporator, to prevent the migration of refrigerant inside the compressor. EVPORTOR Flooded shell and tube evaporator, optimized for HFO1234ze refrigerant. Version two passes, characterized by low pressure losses on the water side. Water tubes with a helical rifled internal surface. Integrated liquid drop separator. Shell, header, tube sheets made of carbon steel, tubes in Cu. nticondensate insulation made of polyurethane. Large liquid level indicator. Temperature sensors on water inlet and outlet. Water flow switch for water flow control on water outlet towards the plant, not installed but supplied in kit. Large liquid level indicator ntifreeze heater. Hydraulic connections with grooved end supplied as standard with flexible joint and adapter pipe to be welded. CONDENSING COIL Microchannel condensing coil in aluminium, perfectly suitable for the civil and industrial applications cooling, while the protection function of the oxide layer allows an optimum resistance to corrosion also in case of aggressive ambient conditions. Extremely light construction. The coil weight is only 50% compared to traditional copper pipes and aluminium fins of the same capacity. Low air side pressure drop and consequentially drastic reduction of the fans motors electric energy consumption. High heat exchange efficiency. Reduced internal volume capable of reducing the total refrigerant charge. t the same performances conditions, the micro-channels condensers require up-to less than 75% refrigerant when compared to the traditional heat exchangers. Single air circuit. Frame in painted galvanized steel. REFRIGERNT CIRCUIT Components for each refrigerant circuit: Capacitive level sensor connected to the driver of the expansion valve. Electronic expansion valve that allows high performance and system efficiency and for the refrigerant level control in the evaporator. By-pass valve for start-up. Non return valve on by-pass line for compressor start. Economizer for model 310 T1E, 520 T2E, 620 T2E, 780 T3E, 900 T3E, 1040 T4E, 1300 T4E. The system includes: - Copper brazed plate type with cover plates, plates and connections in ISI 316 stainless steel. - nticondensate insulation made of polyurethane. - Intermediate electronic expansion valve. Sight glass. Filter dryer on liquid line. Service valve on liquid line. Service valve on gas suction and discharge. Non return valve on gas discharge. Safety valve on low pressure side. Safety valve on high pressure side. Pressure transducers with indication, control and protection functions, on low and high refrigerant pressure. High pressure safety switch with manual reset. Refrigerant circuit with copper tubing with anticondensate insulation of the suction line. Plastic capillary hoses for pressure sensors connection and cooling line of the compressor HFO 1234ze refrigerant charge. ELECTRICL PNEL In accordance with EN norms, suitable for outdoor installation, complete with: Main switch with door lock safety. Fuses for each compressor. Magnetothermic switches for fans or water pumps (if scheduled). Contactors for each load. Transformer for auxiliary circuit and microprocessor supply. Panel with machine controls. Power supply 400/3/50. CONTROL SYSTEM Microprocessor system with Touch Screen graphic display for control and monitor of operating and alarms status. The system includes: - Voltage free contact for remote general alarm. - Voltage free contact for external alarm. The inlet is associable with refrigerant gas leak detector (optional accessory). - Main components hour-meter. - Recording of the last 24 occurred alarms. - Non-volatile Flash memory for data storage. - Menu with protection password. FNS SECTION xial fans with sickle-shaped blades and fan guard optimized for low noise levels designed with bionical know how. Optimized diffusor with static blades. External rotor EC type electric motor with stepless variable speed for condensing pressure control. IP54 enclosure class. 168 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

169 IT Cooling OPTIONL CCESSORIES GOGREEN solutions UNICO TURBO FLG UNICO TURBO FLG Pumping group (1 pump) Pumping group (1+1stby) Pumping group (2 pumps) Pumping group (2+1stby) Pumping group LN (1 pump) Pumping group LN (1+1stby) Pumping group LN (2 pumps) Pumping group LN (2+1stby) LNO kit (noise reduction) ctive filters for containment of the harmonic distortion Rubber support (kit) Condenser partialization system 79 - Electrical panel heating system Double refrigerant circuit 350 -Kit TK PRO corrosion resistant painting treatment nalogic flowmeter Power supply analyzer Multimeter kit Refrigerant gas leak detector Data Logger RC-Com MBUS/JBUS Serial board LON Serial board BCnet Ethernet - SNMP - TCP/IP Serial board BCnet MS/TP Serial board Serial card for GSM Modem Kit modem GSM Plantwatch without modem Remote graphic terminal kit Master plant SEQUENCER RC CLOUD PLTFORM 260 T1 310 T1E 400 T2 520 T2E 620 T2E 700 T3 780 T3E 900 T3E 1040 T4E 1200 T4E 1300 T4E VT2 VT3 VT4 VT5 VT6 VT7 VT7 VT8 VT10 VT11 VT available accessory; - not available accessory fiftycoolyears RCGROUP Sp G_ITC_RCW

170 UNICO TURBO FLG GOGREEN solutions IT Cooling TECHNICL DT UNICO TURBO FLG STNDRD OPT UNICO TURBO FLG Cooling capacity (1) Evaporator water flow rate kpa Evaporator pressure drop Compressors Quantity n. Cooling capacity control (5) % xial fans n. ir circuits n. Refrigerant Total refrigerant charge (optional excluded) Gas circuits n. Power supply V/Ph/Hz Max unit operating current (FL) Unit starting current (LR) EER (1) / ESEER Sound power level [Lw] (2) verage sound pressure level [LPm] (3) Net weight Hydraulic connections Evaporator IN/OUT - OD (4) Ø mm Pumping group 2 poles motor - Power input 4 poles motor - Power input 260 T1 310 T1E 400 T2 520 T2E 620 T2E 700 T3 780 T3E 900 T3E VT3 VT3 VT4 VT5 VT6 VT7 VT7 VT ,3 96,9 124,9 153,3 194,1 218,5 235,4 280,8 44,7 53,3 68,8 89,4 106,6 120,4 134,2 154,8 25,9 36,8 37,0 28,5 40,5 25,7 31,9 42,5 centrifugal centrifugal centrifugal centrifugal centrifugal centrifugal centrifugal centrifugal %...100% 29%...100% 15%...100% 14%...100% 14%...100% 10%...100% 10%...100% 10%...100% HFO1234ze HFO1234ze HFO1234ze HFO1234ze HFO1234ze HFO1234ze HFO1234ze HFO1234ze /3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 185,2 185,2 352,0 361,2 370,4 537,2 537,2 546,4 31,4 31,4 40,2 49,0 57,8 66,6 66,6 75,4 3,20 3,16 3,16 3,36 3,15 3,18 3,28 3,16 4,91 5,47 4,89 5,27 5,69 5,08 5,16 5,77 93,4 93,4 94,8 95,6 96,4 97,1 97,1 97,8 73,9 73,9 74,8 75,1 75,4 75,7 75,7 76, ,3 114,3 168,3 168,3 168,3 168,3 168,3 168, ,5 5,5 11,0 11,0 11,0 11, ,5 5,5 11,0 11,0 11,0 11,0 STNDRD OPT UNICO TURBO FLG Cooling capacity (1) Evaporator water flow rate kpa Evaporator pressure drop Compressors Quantity n. Cooling capacity control (5) % xial fans n. ir circuits n. Refrigerant Total refrigerant charge (optional excluded) Gas circuits n. Power supply V/Ph/Hz Max unit operating current (FL) Unit starting current (LR) EER (1) / ESEER Sound power level [Lw] (2) verage sound pressure level [LPm] (3) Net weight Hydraulic connections Evaporator IN/OUT - OD (4) Ø mm Pumping group 2 poles motor - Power input 4 poles motor - Power input 1040 T4E 1200 T4E 1300 T4E VT9 VT11 VT ,5 369,6 394,9 178,9 206,4 216,7 39,0 51,9 57,2 centrifugal centrifugal centrifugal %...100% 7%...100% 7%...100% HFO1234ze HFO1234ze HFO1234ze /3/50 400/3/50 400/3/50 713,2 731,6 740,9 84,2 101,8 110,6 3,24 3,20 3,14 5,14 5,60 5,94 98,2 99,1 99,5 76,1 76,4 76, ,1 219,1 219,1 22,0 22,0 22,0 11,0 15,0 15,0 1. Referred to chilled water temperature 12/7 C 0% glycol solution; air temperature to the condenser 35 C. Fouling factor of the exchangers 0,018 m² K/. 2. Sound power level [Lw] according to ISO EN verage sound pressure level [LPm] 1m far according to ISO EN Hydraulic connection with grooved end, supplied as standard with flexible joint and adapter pipe. 5. Referred to ambient air temperature at 18 C. DIMENSIONS (mm) VT a b c VT VT VT VT VT VT VT VT VT c b a 170 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

171 FRIGO TURBO FL FRIGO TURBO FL: Packaged water cooled liquid chillers in class energy efficiency for indoor installation, equipped with oil-free centrifugal compressors with magnetic levitation bearings, flooded evaporator and shell and tube condenser. Cooling Capacity: HIGHEFFICIENCY INVERTER CLSS LOWNOISE FRIGO TURBO FL rcgroupairconditioning CLSS INVERTER OIL FREE R134a FLOODED MIN FETURES Water cooled liquid chiller in class energy efficiency. 11 models, 2 versions available, for a wide selection opportunity. verage step of 150. EER up to 5,23. ESEER up to 8,88. Oil-free centrifugal compressors with magnetic levitation bearings. Inverter driven. R134a Refrigerant charge. Single refrigerant circuit. Electronic expansion valve. Shell and tube condenser. Flooded evaporator. Suitable for indoor installation. MIN BENEFITS Up to four centrifugal compressors with magnetic levitation bearings on the refrigerant circuit for an high efficiency. No need of power factor correction. Minimum starting current (LR) High EER and ESEER. Class energy efficiency. Quiet operation. Microprocessor control system with 7 touch screen display. Version with 4-passes condenser for a higher energy efficiency. Extremely easily of maintenance. Complete set of components dedicated to the safety of the unity. Eurovent Certification. INDOOR INSTLLTION The machines are designed for indoor installation. MGNETIC LEVITTION CENTRIFUGL COMPRESSOR The TURBO FL liquid chillers are equipped with two-stage centrifugal compressor with variable speed, which is able to follow punctually plant demands, obtaining values of energy efficiency ratio (EER) growing in a narrowing of the cooling load. The compressors of the TURBO FL liquid chillers are equipped with magnetic levitation oil-free bearings which compared to traditional ball bearings, completely eliminate all the maintenance procedures of lubrication. CLSS ENERGY EFFICIENCY The best and most accurate components applied to the chillers. WORKING LIMITS IN COOLING MODE Chilled water outlet temperature: 4 18 C Condenser outlet water temperature: C fiftycoolyears fiftycoolyears RCGROUP Sp G_ITC_RCW

172 FRIGO TURBO FL COMPONENTS FRMEWORK Base and self supporting frame in steel plate with protective surfaces treatment in compliance with UNI ISO 9227/STMB117 and ISO 7253, and painted with epoxy powders. Colour: RL 9002 COMPRESSORS Twin-turbine centrifugal compressor, oil-free type, optimized for R134a refrigerant. The term oil-free refers to the total absence of lubricating oil within the compressor. Magnetic levitation bearings. Manometric compression ratio: Stepless capacity control trough integrated inverter. High efficiency permanent-magnet synchronous motor with integrated Soft- Start system (starting current limited to 5). Power factor motor cosφ > 0.9 for a large part of the operating range Motor and electronic power section cooling by liquid refrigerant injection into the integrated cooling circuit. Electric motor thermal protection via internal winding temperature sensors. Electronic integrated control for operation and alarms status. Sensor on refrigerant discharge for temperature monitoring. Inner sensors for electronic components and inverter temperature control. Security system to protect the crankshaft and magnetic bearings in the event of failure of power supply. Degree of protection: IP54. ELECTRICLPNEL In accordance with EN norms, suitable for indoor installation, complete with: Main switch with door lock safety. Fuses for compressors. Contactors for compressors. Transformer for auxiliary circuit and microprocessor supply. Panel with machine controls. Power supply 400/3/50. IT Cooling CONTROL SYSTEM Microprocessor system with Touch Screen graphic display for control and monitor of operating and alarms status. The system includes: - Voltage free contact for remote general alarm. - Voltage free contact for external alarm. The inlet is associable with refrigerant gas leak detector (optional accessory). - Main components hour-meter. - Recording of the last 24 occurred alarms. - Non-volatile Flash memory for data storage. - Menu with protection password. EVPORTOR Flooded shell and tube evaporator, optimized for R134a refrigerant. Version two passes, characterized by low pressure losses on the water side. Water tubes with a helical rifled internal surface. Integrated liquid drop separator. Shell, header, tube sheets made of carbon steel, tubes in Cu. nticondensate insulation made of polyurethane. Large liquid level indicator. Temperature sensors on water inlet and outlet. Water flow switch for water flow control on water outlet towards the plant, not installed but supplied in kit. Hydraulic connections with grooved end supplied as standard with flexible joint and adapter pipe to be welded. CONDENSER Shell and tube 2-passes condenser optimized for R134a refrigerant. - Machine type P4: 4-passes condenser. Shell, header, tube sheets made of carbon steel, tubes in Cu. Temperature sensors on condenser water inlet and outlet. Hydraulic connections with grooved end supplied as standard with flexible joint and adapter pipe to be welded. From model 280 T1 to model 560 T2 included the connections are supplied in mounting kit. Installation to be made by the customer. REFRIGERNT CIRCUIT Components for each refrigerant circuit: Capacitive level sensor connected to the driver of the expansion valve. Electronic expansion valve that allows high performance and system efficiency and for the refrigerant level control in the evaporator. Electronic by-pass valve for compressor start. Non return valve on by-pass line for compressor start. Sight glass. Filter dryer on liquid line. Service valve on liquid line. Service valve on gas suction and discharge. Non return valve on gas suction. Safety valve on low pressure side. Safety valve on high pressure side. Pressure transducers with indication, control and protection functions, on low and high refrigerant pressure. High pressure safety switch with manual reset. Refrigerant circuit with copper tubing with anticondensate insulation of the suction line. Plastic capillary hoses for pressure sensors connection. R134a refrigerant charge. 172 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

173 IT Cooling FRIGO TURBO FL OPTIONL CCESSORIES FRIGO TURBO FL Rubber support (kit) Noise absorption cap Service valve on compressor group suction nalogic flowmeter Power supply analyzer Multimeter kit Refrigerant gas leak detector Data Logger RC-Com MBUS/JBUS Serial board LON Serial board BCnet Ethernet - SNMP - TCP/IP Serial board BCnet MS/TP Serial board Serial card for GSM Modem Kit modem GSM Plantwatch without modem Remote graphic terminal kit Master plant SEQUENCER RC CLOUD PLTFORM 280 T1 380 T1 460 T1 560 T2 760 T2 840 T3 920 T T T T T4 available accessory; - not available accessory TECHNICL DT FRIGO TURBO FL (*) STNDRD FRIGO TURBO FL Cooling capacity (1) Evaporator water flow rate Evaporator pressure drop kpa Condenser water flow rate Condenser pressure drop kpa Compressors Quantity n. Capacity control (**) % Refrigerant Total refrigerant charge (optional excluded) Gas circuits n. Power supply V/Ph/Hz Max unit operating current (FL) Unit starting current (LR) EER (1) / ESEER Sound power level [Lw] (2) verage sound pressure level [Lpm] (3) Net weight Hydraulic connections Evaporator IN/OUT - OD (4) Ø mm Condenser IN/OUT - OD (4) Ø mm 280 T1 380 T1 460 T1 560 T2 760 T2 840 T3 920 T T ,4 75,2 90,7 110,9 149,3 166,3 178,6 218,0 48,2 65,4 79,1 96,3 131,0 144,0 158,0 196, ,5 78,0 94,3 115,0 156,0 172,0 188,0 232, centrifugal centrifugal centrifugal centrifugal centrifugal centrifugal centrifugal centrifugal % % % % % 8 100% % 8 100% R134a R134a R134a R134a R134a R134a R134a R134a /3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 141,7 220,5 178,5 283,5 441,0 425,2 357,0 661, ,05 5,05 5,07 5,05 5,09 5,05 5,15 5,23 8,45 8,46 8,63 8,70 8,88 8,53 8,59 8,72 87,5 87,9 89,7 89,7 89,9 90,7 91,8 91,6 69,5 69,9 71,7 71,5 71,7 71,6 73,1 72, ,3 114,3 168,3 168,3 168,3 168,3 168,3 219,1 139,7 139,7 139,7 139,7 168,3 168,3 168,3 168,3 STNDRD FRIGO TURBO FL Cooling capacity (1) Evaporator water flow rate Evaporator pressure drop kpa Condenser water flow rate Condenser pressure drop kpa Compressors Quantity n. Capacity control (**) % Refrigerant Total refrigerant charge (optional excluded) Gas circuits n. Power supply V/Ph/Hz Max unit operating current (FL) Unit starting current (LR) EER (1) / ESEER Sound power level [Lw] (2) verage sound pressure level [Lpm] (3) Net weight Hydraulic connections Evaporator IN/OUT - OD (4) Ø mm Condenser IN/OUT - OD (4) Ø mm 1380 T T T ,5 290,6 358,0 237,0 261,0 316, ,0 310,0 376, centrifugal centrifugal centrifugal % 6 100% 6 100% R134a R134a R134a /3/50 400/3/50 400/3/50 535,5 882,0 714, ,12 5,23 5,14 8,57 8,78 8,73 92,2 92,5 94,0 73,1 73,1 74, ,1 219,1 219,1 168,3 168,3 168,3 1. Referred to chilled water temperature 12/7 C 0% glycol solution; water temperature to the condenser 30/35 C. Fouling factor of the exchangers 0,043 m² K/. 2. Sound power level [Lw] according to ISO EN verage sound pressure level [LPm] 1m far according to ISO EN Hydraulic connection with grooved end, supplied as standard with flexible joint and adapter pipe. (*) Technical data refer to units equipped with 2-passes condenser. (**) Referred to condenser water inlet temperature 18 C fiftycoolyears RCGROUP Sp G_ITC_RCW

174 FRIGO TURBO FL IT Cooling DIMENSIONS (mm) FRIGO TURBO FL a b c 280 T T T T T T T T T T T b a c 174 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

175 FRIGO TURBO FLG FRIGO TURBO FLG: Packaged water cooled liquid chillers in class energy efficiency for indoor installation, equipped with oil-free centrifugal compressors with magnetic levitation bearings, flooded evaporator and shell and tube condenser. Cooling Capacity: HFO1234ze GOGREEN solutions FRIGO TURBO FLG rcgroupairconditioning CLSS INVERTER OIL FREE HIGHEFFICIENCY INVERTER 1234ze CLSS LOWNOISE LOWGWP FLOODED MIN FETURES Water cooled liquid chiller in class energy efficiency. 14 models available for a wide selection opportunity. verage step of 75. EER up to 5,41. ESEER up to 9,10. Oil-free centrifugal compressors with magnetic levitation bearings. Inverter driven. HFO1234ze refrigerant charge, LOW GWP, GWP < 6. Single refrigerant circuit. Electronic expansion valve. Shell and tube condenser. Flooded evaporator. Suitable for indoor installation. MIN BENEFITS Up to four centrifugal compressors with magnetic levitation bearings on the refrigerant circuit for an high efficiency. No need of power factor correction. Minimum starting current (LR) High EER and ESEER. Class energy efficiency. Quiet operation. Microprocessor control system with 7 touch screen display. Version with 4-passes condenser for a higher energy efficiency. Extremely easily of maintenance. Complete set of components dedicated to the safety of the unity. INDOOR INSTLLTION The machines are designed for indoor installation. MGNETIC LEVITTION CENTRIFUGL COMPRESSOR The TURBO FL liquid chillers are equipped with two-stage centrifugal compressor with variable speed, which is able to follow punctually plant demands, obtaining values of energy efficiency ratio (EER) growing in a narrowing of the cooling load. The compressors of the TURBO FL liquid chillers are equipped with magnetic levitation oil-free bearings which compared to traditional ball bearings, completely eliminate all the maintenance procedures of lubrication. CLSS ENERGY EFFICIENCY The best and most accurate components applied to the chillers. WORKING LIMITS IN COOLING MODE Chilled water outlet temperature: 4 18 C Condenser outlet water temperature: C fiftycoolyears fiftycoolyears RCGROUP Sp G_ITC_RCW

176 FRIGO TURBO FLG GOGREEN solutions IT Cooling COMPONENTS FRMEWORK Base and self supporting frame in steel plate with protective surfaces treatment in compliance with UNI ISO 9227/STMB117 and ISO 7253, and painted with epoxy powders. Colour: RL 9002 COMPRESSORS Twin-turbine centrifugal compressor, oil-free type, optimized for HFO1234ze refrigerant. The term oil-free refers to the total absence of lubricating oil within the compressor. Magnetic levitation bearings. Manometric compression ratio: Stepless capacity control trough integrated inverter. High efficiency permanent-magnet synchronous motor with integrated Soft- Start system (starting current limited to 5). Power factor motor cosφ > 0.9 for a large part of the operating range Motor and electronic power section cooling by liquid refrigerant injection into the integrated cooling circuit. Electric motor thermal protection via internal winding temperature sensors. Electronic integrated control for operation and alarms status. Sensor on refrigerant discharge for temperature monitoring. Inner sensors for electronic components and inverter temperature control. Security system to protect the crankshaft and magnetic bearings in the event of failure of power supply. Degree of protection: IP54. ELECTRICLPNEL In accordance with EN norms, suitable for indoor installation, complete with: Main switch with door lock safety. Fuses for compressors. Contactors for compressors. Transformer for auxiliary circuit and microprocessor supply. Panel with machine controls. Power supply 400/3/50. Refrigerant gas leak detector. Supplied in kit. CONTROL SYSTEM Microprocessor system with Touch Screen graphic display for control and monitor of operating and alarms status. The system includes: - Voltage free contact for remote general alarm. - Voltage free contact for external alarm. The inlet is associable with refrigerant gas leak detector. - Main components hour-meter. - Recording of the last 24 occurred alarms. - Non-volatile Flash memory for data storage. - Menu with protection password. EVPORTOR Flooded shell and tube evaporator, optimized for HFO1234ze refrigerant. Version two passes, characterized by low pressure losses on the water side. Water tubes with a helical rifled internal surface. Integrated liquid drop separator. Shell, header, tube sheets made of carbon steel, tubes in Cu. nticondensate insulation made of polyurethane. Large liquid level indicator. Temperature sensors on water inlet and outlet. Water flow switch for water flow control on water outlet towards the plant, not installed but supplied in kit. Hydraulic connections with grooved end supplied as standard with flexible joint and adapter pipe to be welded. CONDENSER Shell and tube 2-passes condenser optimized for HFO1234ze refrigerant. - Machine type P4: 4-passes condenser. Shell, header, tube sheets made of carbon steel, tubes in Cu. Temperature sensors on condenser water inlet and outlet. Hydraulic connections with grooved end supplied as standard with flexible joint and adapter pipe to be welded. From model 250 T1 P4 to model 560 T2 included the connections are supplied in mounting kit. Installation to be made by the customer. REFRIGERNT CIRCUIT Components for each refrigerant circuit: Capacitive level sensor connected to the driver of the expansion valve. Electronic expansion valve that allows high performance and system efficiency and for the refrigerant level control in the evaporator. Electronic by-pass valve for compressor start. Non return valve on by-pass line for compressor start. Economizer for models 310 T1E, 620 T2E, 930 T3E, 1240 T4E. The system includes: - Copper brazed plate type with cover plates, plates and connections in ISI 316 stainless steel. - nticondensate insulation made of polyurethane. - Intermediate electronic expansion valve. Sight glass. Filter dryer on liquid line. Service valve on liquid line. Service valve on gas suction and discharge. Non return valve on gas suction. Safety valve on low pressure side. Safety valve on high pressure side. Pressure transducers with indication, control and protection functions, on low and high refrigerant pressure. High pressure safety switch with manual reset. Refrigerant circuit with copper tubing with anticondensate insulation of the suction line. Plastic capillary hoses for pressure sensors connection. HFO1234ze refrigerant charge. 176 IMPORTNT HFO1234ze refrigerant is mildly flammable. For indoor installations is important to foresee: proper ventilation; a refrigerant gas leak detector (supplied as standard, in kit); pipes connected to the safety valves outlets in order to exhaust vapours outside (not supplied, at customer care). G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

177 IT Cooling OPTIONL CCESSORIES GOGREEN solutions FRIGO TURBO FLG FRIGO TURBO FLG VERSIONE Rubber support (kit) Noise absorption cap Service valve on compressor group suction nalogic flowmeter Power supply analyzer Multimeter kit Data Logger RC-Com MBUS/JBUS Serial board LON Serial board BCnet Ethernet - SNMP - TCP/IP Serial board BCnet MS/TP Serial board Serial card for GSM Modem Kit modem GSM Plantwatch without modem Remote graphic terminal kit Master plant SEQUENCER RC CLOUD PLTFORM 250 T1 280 T1 310 T1E 400 T2 400 T2 500 T2 560 T2 620 T2E 750 T3 840 T3 930 T3E P4 P4 P4 P4 FRIGO TURBO FLG VERSIONE Rubber support (kit) Noise absorption cap Service valve on compressor group suction nalogic flowmeter Power supply analyzer Multimeter kit Data Logger RC-Com MBUS/JBUS Serial board LON Serial board BCnet Ethernet - SNMP - TCP/IP Serial board BCnet MS/TP Serial board Serial card for GSM Modem Kit modem GSM Plantwatch without modem Remote graphic terminal kit Master plant SEQUENCER RC CLOUD PLTFORM 1000 T T T4E P4 available accessory; - not available accessory fiftycoolyears RCGROUP Sp G_ITC_RCW

178 FRIGO TURBO FLG GOGREEN solutions IT Cooling TECHNICL DT FRIGO TURBO FLG STNDRD FRIGO TURBO FLG Cooling capacity (1) Evaporator water flow rate Evaporator pressure drop kpa Condenser water flow rate Condenser pressure drop kpa Compressors Quantity n. Capacity control (**) % Refrigerant Total refrigerant charge (optional excluded) Gas circuits n. Power supply V/Ph/Hz Max unit operating current (FL) Unit starting current (LR) EER (1) / ESEER Sound power level [Lw] (2) verage sound pressure level [Lpm] (3) Net weight Hydraulic connections Evaporator IN/OUT - OD (4) Ø mm Condenser IN/OUT - OD (4) Ø mm 250 T1 P4 280 T1 310 T1E 400 T2 400 T2 P4 500 T2 P4 560 T2 620 T2E ,6 52,5 57,2 73,6 73,0 90,2 104,6 114,8 43,0 48,2 53,3 68,8 68,8 86,0 96,3 106, ,7 57,2 63,2 81,5 50,9 63,4 114,3 126, centrifugal centrifugal centrifugal centrifugal centrifugal centrifugal centrifugal centrifugal % 100% 25% 100% 25% 100% 25% 100% 25% 100% 12% 100% 12% 100% 12% 100% HFO1234ze HFO1234ze HFO1234ze HFO1234ze HFO1234ze HFO1234ze HFO1234ze HFO1234ze /3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 157,5 157,5 157,5 315,0 315,0 315,0 315,0 315, ,41 5,17 5,24 5,26 5,25 5,34 5,20 5,24 8,56 8,29 8,52 8,13 8,46 8,87 8,88 8,94 87,9 87,9 87,9 89,9 89,9 89,9 89,9 89,9 69,6 69,6 69,6 71,4 71,4 71,4 71,4 71, ,3 114,3 114,3 168,3 168,3 168,3 168,3 168,3 88,9 114,3 114,3 114,3 88,9 114,3 139,7 168,3 STNDRD FRIGO TURBO FLG Cooling capacity (1) Evaporator water flow rate Evaporator pressure drop kpa Condenser water flow rate Condenser pressure drop kpa Compressors Quantity n. Capacity control (**) % Refrigerant Total refrigerant charge (optional excluded) Gas circuits n. Power supply V/Ph/Hz Max unit operating current (FL) Unit starting current (LR) EER (1) / ESEER Sound power level [Lw] (2) verage sound pressure level [Lpm] (3) Net weight Hydraulic connections Evaporator IN/OUT - OD (4) Ø mm Condenser IN/OUT - OD (4) Ø mm 750 T3 P4 840 T3 930 T3E 1000 T4 P T T4E ,6 158,4 170,1 177,8 208,5 226,7 129,0 144,5 160,0 172,0 192,6 213, ,0 171,7 189,2 126,6 228,5 252, centrifugal centrifugal centrifugal centrifugal centrifugal centrifugal % 100% 8% 100% 13% 100% 8% 100% 8% 100% 9% 100% HFO1234ze HFO1234ze HFO1234ze HFO1234ze HFO1234ze HFO1234ze /3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 472,5 472,5 472,5 630,0 630,0 630, ,41 5,16 5,31 5,41 5,17 5,25 9,10 8,92 8,92 8,89 8,65 8,70 91,6 91,6 91,6 92,5 92,5 92,5 72,8 72,8 72,8 73,3 73,3 73, ,3 168,3 168,3 219,1 219,1 219,1 139,7 168,3 168,3 139,7 168,3 168,3 1. Referred to chilled water temperature 12/7 C 0% glycol solution; water temperature to the condenser 30/35 C. Fouling factor of the exchangers 0,018 m² K/. 2. Sound power level [Lw] according to ISO EN verage sound pressure level [LPm] 1m far according to ISO EN Hydraulic connection with grooved end, supplied as standard with flexible joint and adapter pipe. (**) Referred to condenser water inlet temperature 18 C. DIMENSIONS (mm) FRIGO TURBO FL a b c 250 T1 P T T1E T T2 P T2 P T T2E T3 P T T3E T4 P T T4E b a c 178 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

179 TEM MTE TEM MTE: ir cooled condensers equipped with axial fans Capacity: TEM MTE rcgroupairconditioning R410 R407c R134a C SPLIT SYSTEM MIN FETURES ir cooled condensers. 19 models available, for a wide selection opportunity. verage step of 15. Multi-refrigerant charge. Supplied with seal charge. C xial fans. Horizontal air flow. Suitable for outdoor installation. OUTDOOR INSTLLTION The machines are made with weather resistant materials and suitable for outdoor installation. MIN BENEFITS Designed for the perfect match with RC Group motoevaporating units. vailability of machine for the reduction and the extreme reduction of the noise. vailability of support leg for vertical air flow. Easily of maintenance fiftycoolyears fiftycoolyears RCGROUP Sp G_ITC_RCW

180 TEM MTE MIN COMPONENTS FRMEWORK Base, self supporting frame and panelling in steel plate with protective surfaces treatment in compliance with UNI ISO 9227/STMB117 and ISO 7253, and painted with epoxy powders. Colour: RL 9002 FNS SECTION TEM MTE xial fans with sickle-shaped blades, fan guard and optimized for low noise levels. External rotor electric motor, C type, with stepless variable speed for condensing pressure control. The motor rotation control is obtained according to the 0 10V proportional signal coming from the internal unit microprocessor control. IP54 enclosure class. IT Cooling ELECTRICL PNEL In accordance with EN norms, suitable for outdoor installation, IP54 enclosure class, complete with: Terminals for power supply (from network) /3/50+N for models T - 230/1/50 for models M. Terminals for 0 10V signal for condensing control system (connect to indoor machine). Terminals for alarm signal (connect to indoor machine). Fans speed regulator for condensing control. OPTIONL CCESSORY Support legs for vertical air flow. IR/GS HET EXCHNGERS Heat exchanger coil with internally corrugated copper tubes and high efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops. The combination of two factors, special tubes and fins, allow to optimally combine the following aspects: - Maximum capacity relative to the size of the exchanger. - Minimum charge of refrigerant. - Reduction of the air flow required for the heat exchange. Frame in galvanized steel. REFRIGERNT CIRCUIT Valves on gas and liquid line for coupling to refrigerant pipe. The valves are supplied not installed. The condenser is supplied with nitrogen seal. TECHNICL DT TEM MTE STNDRD TEM MTE ELN TEM MTE LNO TEM MTE Capacity (1) With refrigerant charge R410 With refrigerant charge R407C With refrigerant charge R134a xial fans n. ir circuits n. Total refrigerant charge (optional excluded) Gas circuits n. Power supply V/Ph/Hz Max unit operating current (FL) Sound power level [Lw] (2) verage sound pressure level [Lpm] (3) Net weight Refrigerant connections Liquid line ODS Ø mm Gas line ODS Ø mm Capacity (1) With refrigerant charge R410 With refrigerant charge R407C With refrigerant charge R134a Sound power level [Lw] (2) verage sound pressure level [Lpm] (3) Capacity (1) With refrigerant charge R410 With refrigerant charge R407C With refrigerant charge R134a Sound power level [Lw] (2) verage sound pressure level [Lpm] (3) 1. Referred to condensation temperature 50 C; ambient temperature 35 C. 2. Sound power level [Lw] according to ISO EN verage sound pressure level [LPm] 1m far according to ISO EN M 11 M 14 M 17 M 20 M 25 M 30 M 35 M 45 12,1 14,7 18,4 20,7 24,2 32,7 37,4 47,6 12,0 14,7 18,2 20,4 24,2 32,3 37,1 47,1 11,7 14,4 17,9 20,0 23,7 31,7 36,6 46,5 0,3 0,3 0,3 0,4 0,5 0,5 0,5 0, ,8 1,2 1,7 1,7 2,0 3,0 4,0 4, /1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 1,2 1,2 1,2 1,8 2,9 2,9 2,9 3,6 76,8 76,8 77,1 79,1 81,8 81,8 81,8 82,4 63,0 63,0 63,0 65,0 67,0 67,0 67,0 67, ,9 13,1 16,4 18,5 21,8 29,1 32,9 42,0 10,8 13,1 16,2 18,2 21,8 28,7 32,6 41,6 10,6 12,9 15,9 17,9 21,3 28,3 32,3 41,1 0,2 0,2 0,2 0,3 0,5 0,5 0,5 0, ,9 72,9 73,2 75,2 77,9 77,9 77,9 78,5 59,1 59,1 59,1 61,1 63,1 63,1 63,1 63,6 9,6 11,4 14,1 16,1 19,2 25,2 28,2 36,1 9,5 11,4 14,0 15,8 19,2 24,9 27,9 35,7 9,3 11,2 13,8 15,6 18,8 24,5 27,6 35,3 0,2 0,2 0,2 0,3 0,4 0,4 0,4 0, ,2 68,2 68,6 70,6 73,3 73,3 73,3 73,9 54,5 54,5 54,5 56,5 58,5 58,5 58,5 58,9 180 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

181 IT Cooling TEM MTE TECHNICL DT TEM MTE STNDRD TEM MTE ELN TEM MTE LNO STNDRD TEM MTE ELN TEM MTE LNO TEM MTE Capacity (1) With refrigerant charge R410 With refrigerant charge R407C With refrigerant charge R134a xial fans n. ir circuits n. Total refrigerant charge (optional excluded) Gas circuits n. Power supply V/Ph/Hz Max unit operating current (FL) Sound power level [Lw] (2) verage sound pressure level [Lpm] (3) Net weight Refrigerant connections Liquid line ODS Ø mm Gas line ODS Ø mm Capacity (1) With refrigerant charge R410 With refrigerant charge R407C With refrigerant charge R134a Sound power level [Lw] (2) verage sound pressure level [Lpm] (3) Capacity (1) With refrigerant charge R410 With refrigerant charge R407C With refrigerant charge R134a Sound power level [Lw] (2) verage sound pressure level [Lpm] (3) TEM MTE Capacity (1) With refrigerant charge R410 With refrigerant charge R407C With refrigerant charge R134a xial fans n. ir circuits n. Total refrigerant charge (optional excluded) Gas circuits n. Power supply V/Ph/Hz Max unit operating current (FL) Sound power level [Lw] (2) verage sound pressure level [Lpm] (3) Net weight Refrigerant connections Liquid line ODS Ø mm Gas line ODS Ø mm Capacity (1) With refrigerant charge R410 With refrigerant charge R407C With refrigerant charge R134a Sound power level [Lw] (2) verage sound pressure level [Lpm] (3) Capacity (1) With refrigerant charge R410 With refrigerant charge R407C With refrigerant charge R134a Sound power level [Lw] (2) verage sound pressure level [Lpm] (3) 1. Referred to condensation temperature 50 C; ambient temperature 35 C. 2. Sound power level [Lw] according to ISO EN verage sound pressure level [LPm] 1m far according to ISO EN M 50 M 60 M 70 M 95 M 110 M 130 M 140 T ,1 62,6 74,0 99,4 111,0 133,0 151,0 201,0 55,5 62,0 73,3 98,3 110,0 132,0 150,0 198,0 54,8 61,2 72,4 97,0 109,0 130,0 149,0 195,0 1,1 1,1 1,1 1,6 1,6 2,1 2,1 3, ,1 5,5 7,7 8,7 11,6 11,6 15,4 20, /1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 400/3/50+N 5,7 5,7 5,7 8,5 8,5 11,4 11,4 17,1 84,5 84,5 85,0 86,9 86,9 88,1 88,1 88,8 69,4 69,4 69,4 70,5 70,5 71,1 71,1 71, ,1 55,3 65,1 88,3 97,7 118,0 133,0 179,0 49,6 54,8 64,6 87,4 97,3 117,0 132,0 176,0 48,9 54,2 63,8 86,3 96,2 116,0 131,0 174,0 0,9 0,9 0,9 1,4 1,4 1,8 1,8 2, ,7 80,7 81,1 83,0 83,0 84,2 84,2 84,9 65,5 65,5 65,5 66,6 66,6 67,2 67,2 67,7 43,5 47,6 55,8 76,4 83,7 102,0 114,0 155,0 43,1 47,2 55,3 75,7 83,3 101,0 113,0 153,0 42,6 46,7 54,7 74,8 82,5 100,0 112,0 151,0 0,8 0,8 0,8 1,1 1,1 1,5 1,5 2, ,0 76,0 76,5 78,4 78,4 79,6 79,6 80,3 60,8 60,8 60,8 61,9 61,9 62,5 62,5 63,0 T 210 T 250 T ,0 276,0 307,0 231,0 273,0 304,0 228,0 270,0 301,0 3,2 4,2 4, ,7 27,7 37, /3/50+N 400/3/50+N 400/3/50+N 17,1 22,8 22,8 88,8 90,1 90,1 71,5 72,2 72, ,0 245,0 270,0 203,0 243,0 268,0 201,0 240,0 265,0 2,7 3,6 3, ,9 86,2 86,2 67,7 68,3 68,3 175,0 212,0 231,0 173,0 210,0 229,0 172,0 208,0 227,0 2,2 3,0 3, ,3 81,5 81,5 63,0 63,7 63, fiftycoolyears RCGROUP Sp G_ITC_RCW

182 TEM MTE IT Cooling DIMENSIONS (mm) TEM MTE a b c M M M M M M M M M M M M M M M T T T T c b a (*) please refer to technical catalogues for further information about connections dimensions 182 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

183 TEM MTE PF TEM MTE PF: ir cooled condensers equipped with plug fan Capacity: TEM MTE PF R410 R407c R134a E C SPLIT SYSTEM MIN FETURES ir cooled condensers. 14 models available, for a wide selection opportunity. verage step of 10. Multi-refrigerant charge. Supplied with seal charge. EC Plug-fan. Horizontal/Vertical air flow. Suitable for indoor installation. MIN BENEFITS Designed for the perfect match with RC Group motoevaporating units. EC Plug fan for a high efficiency. vailability of machine for the reduction and the extreme reduction of the noise. vailability of horizontal and vertical air delivery. To change air delivery mode it s simply required the change of position of a single panel. Easily of maintenance. FNS WITH BRUSHLESS TYPE EC MOTOR The fans electric motors are the brushless type with built-in electronic commutation system (EC) which yield high energy savings during operation in reduced air flow. These electric motors are ensuring high performances, minimum energy consumption and total absence of electromagnetic noise INDOOR INSTLLTION The machines are designed for indoor installation and ducting for air suction and discharge. For outdoor installation the use of the dedicated optional kit is mandatory. The machine must be installed under a cover or anyway protected against atmospherics agent fiftycoolyears fiftycoolyears RCGROUP Sp G_ITC_RCW

184 TEM MTE PF MIN COMPONENTS FRMEWORK Base, self supporting frame and panelling in steel plate with protective surfaces treatment in compliance with UNI ISO 9227/STMB117 and ISO 7253, and painted with epoxy powders. Colour: RL 9002 FNS SECTION TEM MTE Centrifugal fans with backward curved blades with wing profile, single suction and without scroll housings (Plug-fan). Brushless type synchronous EC motor with integrated electronic commutated system and continuous variation of the rotation speed. The motor rotation control is obtained with the EC system (Electronic Commutation) that manage the motor according to the 0 10V proportional signal coming from the internal unit microprocessor control. Maintenance-free bearings IP54 enclosure class. IT Cooling REFRIGERNT CIRCUIT Valves on gas and liquid line for coupling to refrigerant pipe. The valves are supplied not installed. The condenser is supplied with nitrogen seal. ELECTRICL PNEL In accordance with EN norms, suitable for outdoor installation, IP54 enclosure class, complete with: Terminals for power supply (from network) /3/50-60 for models T Terminals for 0 10V signal for condensing control system (connect to indoor machine). Terminals for alarm signal (connect to indoor machine). IR/GS HET EXCHNGERS Heat exchanger coil with internally corrugated copper tubes and high efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops. The combination of two factors, special tubes and fins, allow to optimally combine the following aspects: - Maximum capacity relative to the size of the exchanger. - Minimum charge of refrigerant. - Reduction of the air flow required for the heat exchange. Frame in galvanized steel. TECHNICL DT TEM MTE PF STNDRD TEM MTE PF ELN TEM MTE PF LNO TEM MTE PF Capacity (1) With refrigerant charge R410 With refrigerant charge R407C With refrigerant charge R134a Plug-fans n. vailable static pressure Pa Max available static pressure Pa ir circuits n. Total refrigerant charge (optional excluded) Gas circuits n. Power supply V/Ph/Hz Max unit operating current (FL) Sound power level [Lw] (2) verage sound pressure level [Lpm] (3) Net weight Refrigerant connections Liquid line ODS Ø mm Gas line ODS Ø mm Capacity (1) With refrigerant charge R410 With refrigerant charge R407C With refrigerant charge R134a vailable static pressure Pa Sound power level [Lw] (2) verage sound pressure level [Lpm] (3) Capacity (1) With refrigerant charge R410 With refrigerant charge R407C With refrigerant charge R134a vailable static pressure Pa Sound power level [Lw] (2) verage sound pressure level [Lpm] (3) 1. Referred to condensation temperature 50 C; ambient temperature 35 C. 2. Sound power level [Lw] according to ISO EN verage sound pressure level [LPm] 1m far according to ISO EN T 11 T 14 T 17 T 21 T 24 T 33 T 38 T 44 12,1 15,6 18,2 21,6 25,0 35,1 39,8 46,5 12,0 15,6 18,2 21,6 25,0 35,1 39,8 46,5 11,7 15,3 17,9 21,3 24,7 34,7 39,3 46,0 0,4 0,4 0,5 0,5 0,6 1,3 1,1 1, ,8 1,2 1,7 2,6 2,5 3,8 4,3 6, /3/ /3/ /3/ /3/ /3/ /3/ /3/ /3/ ,6 1,6 1,6 1,6 4,3 4,3 3,6 3,6 76,2 76,2 76,1 76,1 82,5 87,4 86,6 86,8 61,6 61,6 61,5 61,5 67,1 72,0 71,1 71, ,8 13,7 15,9 18,8 21,6 30,2 34,5 40,1 10,5 13,7 15,9 18,8 21,6 30,2 34,5 40,1 10,2 13,3 15,5 18,4 21,0 29,4 33,7 39,3 0,3 0,3 0,3 0,3 0,4 0,8 0,7 0, ,3 72,3 72,2 72,2 78,6 83,5 82,7 82,9 57,7 57,7 57,6 57,6 63,2 68,1 67,2 67,4 9,5 11,9 13,7 16,0 18,7 25,8 29,7 34,0 9,3 11,9 13,7 16,0 18,7 25,8 29,7 34,0 9,1 11,6 13,4 15,7 18,2 25,2 29,1 33,5 0,2 0,2 0,2 0,2 0,3 0,5 0,5 0, ,6 67,6 67,5 67,5 73,9 78,8 78,1 78,3 53,1 53,1 53,0 53,0 58,6 63,5 62,6 62,8 184 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

185 IT Cooling TEM MTE PF TECHNICL DT TEM MTE PF STNDRD TEM MTE PF ELN TEM MTE PF LNO TEM MTE PF Capacity (1) With refrigerant charge R410 With refrigerant charge R407C With refrigerant charge R134a Plug-fans n. vailable static pressure Pa Max available static pressure Pa ir circuits n. Total refrigerant charge (optional excluded) Gas circuits n. Power supply V/Ph/Hz Max unit operating current (FL) Sound power level [Lw] (2) verage sound pressure level [Lpm] (3) Net weight Refrigerant connections Liquid line ODS Ø mm Gas line ODS Ø mm Capacity (1) With refrigerant charge R410 With refrigerant charge R407C With refrigerant charge R134a vailable static pressure Pa Sound power level [Lw] (2) verage sound pressure level [Lpm] (3) Capacity (1) With refrigerant charge R410 With refrigerant charge R407C With refrigerant charge R134a vailable static pressure Pa Sound power level [Lw] (2) verage sound pressure level [Lpm] (3) 1. Referred to condensation temperature 50 C; ambient temperature 35 C. 2. Sound power level [Lw] according to ISO EN verage sound pressure level [LPm] 1m far according to ISO EN T 58 T 69 T 86 T108 T114 T144 62,0 73,1 91,0 113,0 122,0 154,0 62,0 73,1 91,0 113,0 122,0 154,0 61,2 72,4 89,9 111,0 121,0 152,0 2,2 2,4 3,3 4,7 5,6 7, ,9 8,8 10,2 10,3 9,4 14, /3/ /3/ /3/ /3/ /3/ /3/ ,6 8,6 12,9 17,2 12,9 17,2 93,4 93,5 96,9 98,7 100,3 101,4 77,3 77,4 80,3 81,8 83,7 84, ,4 62,7 78,6 98,9 105,0 131,0 53,4 62,7 78,6 98,9 105,0 131,0 51,8 61,3 76,2 96,2 102,0 127,0 1,4 1,5 2,2 3,0 3,6 4, ,5 89,6 93,0 94,8 96,4 97,5 73,4 73,5 76,4 77,9 79,8 80,6 46,2 53,4 68,1 85,9 89,8 113,0 46,2 53,4 68,1 85,9 89,8 113,0 45,0 52,4 66,4 83,8 87,9 110,0 0,8 0,9 1,3 1,8 2,1 2, ,8 84,9 88,3 90,2 91,7 92,9 68,8 68,9 71,8 73,3 75,2 76, fiftycoolyears RCGROUP Sp G_ITC_RCW

186 TEM MTE PF IT Cooling DIMENSIONS (mm) TEM MTE PF a b c T T T T T T T T T T T T T T (*) please refer to technical catalogues for further information about connections dimensions a b c 186 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

187 IT Cooling DRY COOLER DRY COOLER: Dry coolers equipped with axial fans Capacity: DRY COOLER rcgroupairconditioning C MIN FETURES Dry coolers. 10 models available, for a wide selection opportunity. verage step of 15. Water feeding. C xial fans. Horizontal air flow. Suitable for outdoor installation. OUTDOOR INSTLLTION The machines are made with weather resistant materials and suitable for outdoor installation. MIN BENEFITS Designed for the perfect match with RC Group water cooled liquid chillers. vailability of machine for the reduction and the extreme reduction of the noise. vailability of support leg for vertical air flow. Easily of maintenance fiftycoolyears fiftycoolyears RCGROUP Sp G_ITC_RCW

188 DRY COOLER MIN COMPONENTS FRMEWORK Base, self supporting frame and panelling in steel plate with protective surfaces treatment in compliance with UNI ISO 9227/STMB117 and ISO 7253, and painted with epoxy powders. Colour: RL 9002 FNS SECTION xial fans with sickle-shaped blades, fan guard and optimized for low noise levels. External rotor electric motor, C type, with stepless variable speed for condensing pressure control. The motor rotation control is obtained according to the 0 10V proportional signal coming from the internal unit microprocessor control. IP54 enclosure class. DISSIPTIVE COIL Heat exchanger coil with copper tubes and high efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops. IT Cooling The combination of two factors, special tubes and fins, allow to optimally combine the following aspects: - Maximum capacity relative to the size of the exchanger. - Reduction of the air flow required for the heat exchange. Frame in galvanized steel. ELECTRICL PNEL In accordance with EN norms, suitable for outdoor installation, IP54 enclosure class, complete with: Terminals for power supply (from network) /3/50+N for models T - 230/1/50 for models M. Terminals for 0 10V signal for fan speed control (connect to indoor machine). Terminals for alarm signal (connect to indoor machine). Fans speed regulator for fan speed control. OPTIONL CCESSORY Support legs for vertical air flow TECHNICL DT DRY COOLER STNDRD LNO 70% LNO 85% DRY COOLER Capacity (1) xial fans n. ir circuits n. Water flow Pressure drops kpa Water content l Power supply V/Ph/Hz Max unit operating current (FL) Sound power level [Lw] (2) verage sound pressure level [Lpm] (3) Net weight Hydraulic connections Inlet / Outlet ISO 7/1 R Ø Capacity (1) Water flow Pressure drops kpa Sound power level [Lw] (2) verage sound pressure level [Lpm] (3) Capacity (1) Water flow Pressure drops kpa Sound power level [Lw] (2) verage sound pressure level [Lpm] (3) 1. Characteristics referred to entering air at 35 C with hot water inlet temperature 45 C 20% glycol. 2. Sound power level [Lw] according to ISO EN verage sound pressure level [LPm] 1m far according to ISO EN (*) vailable also with 230/1/50 power supply. Refer to the wiring diagram of the unit. M 14 M 20 M 35 M 45 M 60 M 70 M 110 M 140 T 210 T 280 8,3 11,7 22,6 26,4 31,8 40,2 62,2 86,1 124,0 172,0 0,3 0,4 0,5 0,8 1,1 1,1 1,6 2,1 3,2 4, ,5 2,1 4,0 4,7 5,7 7,2 11,1 15,4 22,1 30, ,0 5,7 15,7 15,2 17,9 25,1 37,7 72,8 75,3 100,4 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 400/3/50+N(*) 400/3/50+N(*) 0,7 1,8 2,9 3,6 5,7 5,7 8,5 11,4 17,1 22,8 76,8 79,1 81,8 82,4 84,5 85,0 86,9 88,1 88,8 90,1 63,0 65,0 67,0 67,4 69,4 69,4 70,5 71,1 71,5 72, /4" 1 1/4" 1 1/2" 1 1/2" 2" 2" 2" 2" 2 1/2" 3" 7,3 10,4 19,8 23,3 28,0 35,3 54,8 75,9 109,0 152,0 0,3 0,4 0,5 0,8 1,1 0,9 1,4 1,8 2,7 3, ,3 1,9 3,5 4,2 5,0 6,3 9,8 13,6 19,5 27, ,9 75,2 77,9 78,5 80,7 81, ,2 84,9 86,2 59,1 61,1 63,1 63,6 65,5 65,5 66,6 67,2 67,7 68,3 6,4 9,0 16,9 19,9 23,8 30,2 46,9 65,0 93,2 130,0 0,2 0,3 0,4 0,6 0,8 0,8 1,1 1,5 2,2 3, ,1 1,6 3,0 3,6 4,3 5,4 8,4 11,6 16,7 23, ,2 70,6 73,3 73,9 76,0 76,5 78,4 79,6 80,3 81,5 54,5 56,5 58,5 58,9 60,8 60,8 61,9 62,5 63,0 63,7 DIMENSIONS (mm) DRY COOLER a b c M M M M M M M M T T (*) please refer to technical catalogues for further information about connections dimensions c b a 188 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

189 IT Cooling DRY COOLER PF DRY COOLER PF: Dry coolers equipped with plug fan Capacity: 8,8 89,0 DRY COOLER PF rcgroupairconditioning E C MIN FETURES Dry coolers. 13 models available, for a wide selection opportunity. verage step of 6. Water feeding. EC Plug-fan. Horizontal/Vertical air flow. Suitable for indoor installation. MIN BENEFITS Designed for the perfect match with RC Group water cooled liquid chillers. EC Plug fan for a high efficiency. vailability of machine for the reduction and the extreme reduction of the noise. vailability of horizontal and vertical air delivery. To change air delivery mode it s simply required the change of position of a single panel. Easily of maintenance. PLUG FNS WITH BRUSHLESS TYPE EC MOTOR The fans electric motors are the brushless type with built-in electronic commutation system (EC) which yield high energy savings during operation in reduced air flow. These electric motors are ensuring high performances, minimum energy consumption and total absence of electromagnetic noise INDOOR INSTLLTION The machines are designed for indoor installation and ducting for air suction and discharge. For outdoor installation the use of the dedicated optional kit is mandatory. The machine must be installed under a cover or anyway protected against atmospherics agent fiftycoolyears fiftycoolyears RCGROUP Sp G_ITC_RCW

190 DRY COOLER PF IT Cooling MIN COMPONENTS FRMEWORK Base, self supporting frame and panelling in steel plate with protective surfaces treatment in compliance with UNI ISO 9227/STMB117 and ISO 7253, and painted with epoxy powders. Colour: RL 9002 FNS SECTION TEM MTE Centrifugal fans with backward curved blades with wing profile, single suction and without scroll housings (Plug-fan). Brushless type synchronous EC motor with integrated electronic commutated system and continuous variation of the rotation speed. The motor rotation control is obtained with the EC system (Electronic Commutation) that manage the motor according to the 0 10V proportional signal coming from the internal unit microprocessor control. Maintenance-free bearings IP54 enclosure class. DISSIPTIVE COIL Heat exchanger coil with copper tubes and high efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops. The combination of two factors, special tubes and fins, allow to optimally combine the following aspects: - Maximum capacity relative to the size of the exchanger. - Reduction of the air flow required for the heat exchange. Frame in galvanized steel. ELECTRICL PNEL In accordance with EN norms, suitable for outdoor installation, IP54 enclosure class, complete with: Terminals for power supply (from network) /3/50-60 for models T Terminals for 0 10V signal for fan speed control (connect to indoor machine). Terminals for alarm signal (connect to indoor machine). 190 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

191 IT Cooling DRY COOLER PF TECHNICL DT DRY COOLER PF STNDRD LNO 70% LNO 85% STNDRD LNO 70% LNO 85% DRY COOLER PF Capacity (1) xial fans n. vailable static pressure Pa Max available static pressure Pa ir circuits n. Water flow Pressure drops kpa Water content l Power supply V/Ph/Hz Max unit operating current (FL) Sound power level [Lw] (2) verage sound pressure level [Lpm] (3) Net weight Hydraulic connections Inlet / Outlet ISO 7/1 R Ø Capacity (1) Water flow Pressure drops kpa Sound power level [Lw] (2) verage sound pressure level [Lpm] (3) Capacity (1) Water flow Pressure drops kpa Sound power level [Lw] (2) verage sound pressure level [Lpm] (3) DRY COOLER PF Capacity (1) xial fans n. vailable static pressure Pa Max available static pressure Pa ir circuits n. Water flow Pressure drops kpa Water content l Power supply V/Ph/Hz Max unit operating current (FL) Sound power level [Lw] (2) verage sound pressure level [Lpm] (3) Net weight Hydraulic connections Inlet / Outlet ISO 7/1 R Ø Capacity (1) Water flow Pressure drops kpa Sound power level [Lw] (2) verage sound pressure level [Lpm] (3) Capacity (1) Water flow Pressure drops kpa Sound power level [Lw] (2) verage sound pressure level [Lpm] (3) T 14 T 17 T 21 T 24 T 33 T 38 T 44 T 58 8,8 10,5 12,6 13,7 20,6 24,3 28,0 31,8 0,4 0,5 0,5 0,6 1,3 1,1 1,2 2, ,6 1,9 2,3 2,4 3,7 4,3 5,0 5, ,9 5,2 7,8 7,4 11,1 12,7 19,1 17, /3/ /3/ /3/ /3/ /3/ /3/ /3/ /3/ ,6 1,6 1,6 4,3 4,3 3,6 3,6 8,6 76,2 76,1 76,1 82,5 87,4 86,6 86,8 93,4 61,6 61,5 61,5 67, ,1 71,3 77, /4" 1 1/4" 1 1/4" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 2" 7,8 9,2 11,0 12,1 18,0 21,4 24,5 28,0 0,3 0,3 0,3 0,4 0,8 0,7 0,8 1, ,4 1,7 2,0 2,2 3,2 3,8 4,4 5, ,3 72,2 72,2 78,6 83,5 82,7 82,9 89,5 57,7 57,6 57,6 63,2 68,1 67,2 67,4 73,4 6,8 8,0 9,3 10,3 15,4 18,3 20,6 23,8 0,2 0,2 0,2 0,3 0,5 0,5 0,5 0, ,2 1,4 1,7 1,9 2,8 3,3 3,7 4, ,6 67,5 67,5 73,9 78,8 78,1 78,3 84,8 53,1 53,0 53,0 58,6 63,5 62,6 62,8 68,8 T 69 T 86 T108 T114 T144 41,9 50,0 60,3 68,8 89,0 2,4 3,3 4,7 5,6 7, ,5 9,0 10,8 12,3 15, ,2 24,5 28,0 36,7 41, /3/ /3/ /3/ /3/ /3/ ,6 12,9 17,2 12,09 17,2 93,5 96,9 98,7 100,3 101,4 77,4 80,3 81,8 83,7 84, " 2" 2" 2" 2" 36,7 44,3 53,3 60,4 78,3 1,5 2,2 3,0 3,6 4, ,6 7,9 9,5 10,8 14, ,6 93,0 94,8 96,4 97,5 73,5 76,4 77,9 79,8 80,6 31,1 38,1 45,8 51,4 67,0 0,9 1,3 1,8 2,1 2, ,6 6,8 8,2 9,2 12, ,9 88,3 90,2 91,7 92,9 68,9 71,8 73,3 75,2 76,0 1. Characteristics referred to entering air at 35 C with hot water inlet temperature 45 C 20% glycol. 2. Sound power level [Lw] according to ISO EN verage sound pressure level [LPm] 1m far according to ISO EN (*) vailable also with 230/1/50 power supply. Refer to the wiring diagram of the unit fiftycoolyears RCGROUP Sp G_ITC_RCW

192 DRY COOLER PF IT Cooling DIMENSIONS (mm) DRY COOLER PF a b c T T T T T T T T T T T T T a (*) please refer to technical catalogues for further information about connections dimensions b c 192 G_ITC_RCW8.4 RCGROUP Sp fiftycoolyears

193 RCWORLD RC World RC WORLD: RC Group products selection software rc world rcgroupairconditioning MIN FETURES 5 applications: Products selection. Unit performances. Price list. Offer management. Orders management. RC WORLD MIN NEW FETURES Introduction of the new product range. Improved unit selection mode. 8 languages: Deutsch English Espanol Francais Italiano Norsk Polski Russian Suomi Swedish MIN BENEFITS RC World calculates the performance of all the RC Group product range at every admitted working conditions. RC World shows the descriptions and the technical drawings of the units. RC World shows the optional accessory of the units fiftycoolyears RCGROUP Sp G_ITC_RCW_

194 Spectrum RCSPECTRUM SPECTRUM: Energy performance estimation software for chillers, heat pumps and multifunction produced by RC Group Free application, available at the website Requires only: RC WORLD (electronic catalogue) registration llows: step-by-step user friendly interface graphical outputs in PDF format and numerical outputs in XLSX format Periodic update of database and mathematical models spectrum rcgroupairconditioning MIN FETURES WEB application able to predict the Energy performance of the units (chillers and heat pumps) and to conduct a comprehensive energy analysis. Energy performance of whatever unit in a specific operating condition ( ONE SHOT mode): Gross and net EER (chillers). TER (chillers with heat recovery). Gross and net COP (heat pumps, with estimation of defrost for air-towater units). MIN BENEFITS For planners: id in the choice of machines and their conduction. nalysis of return on investment. Easy integration of results into project documentation. For Energy Managers: Tool to verify predicted performances. Integration with BMS/SEQ to optimize operational logic. Evaluation of standard indexes: ESEER, IPLV. SEER. SCOP. Energy analysis (one year-based estimation): Single machine. Multiple configuration of a single model, with parallel or sequential mode of insertion. Comparison of different models on the same application. Complex layout, with machines of different models and size, with sequencing rules in accordance to SEQ functions G_ITC_RCW_8.4 RCGROUP Sp fiftycoolyears

195 RCSPECTRUM Spectrum Tutorial SPECTRUM: Video Tutorial 5 VIDEOS (1 TRILER + 4 CHPTERS) vailable in 5 languages (ITLIN, ENGLISH; GERMN, SPNISH, RUSSIN) TRILER tutorial rcgroupairconditioning VIDEO INDEX CHPTER 1 Export of machine data to analyse from RC WORLD and introduction to SPECTRUM CHPTER 3 Spectrum: NLYSIS INDEX CHPTER 2 Spectrum: ONE SHOT NLYSIS CHPTER 4 Spectrum: ENERGY NLYSIS fiftycoolyears RCGROUP Sp G_ITC_RCW_

196 Sequencer SEQUENCER SEQUENCER: Sequencer for chillers, heat pumps and multifunction units sequencer rcgroupairconditioning MIN FETURES The sequencer SEQ is designed as a master unit in a network of different machines connected in a single hydronic network for the production of chilled or heated water. 2-pipe, 4-pipe plants. Machines different for type and size (with a maximum of 5 units). Management of units made by others. Designed to work alone or in combination with a supervisor (BMS). MIN BENEFITS ctive control: utomatic activation / deactivation of the units depending on changeover, alarms, temperature control, limit conditions, special events (e.g. restart after power failure). Plant temperature precision control. Improvement and control of system energy efficiency. Pumps control. Others plant management functions: coustic limiting, by the definition of reduced thresholds for fan speed. Demand limiting (limitation of electrical power absorption). Time scheduling. Changeover, with the goal of equalize the working hours of all devices. ntifreeze function integration. Passive control: Collection of all signal alarms coming from the units. Report of faults and events. Request of pre-programmed maintenance activities. 196 G_ITC_RCW_8.4 RCGROUP Sp fiftycoolyears

197 COOLNET Cool Net COOL NET: Intelligent NET for IT cooling that maximizes the energy saving in LOD SHRING STND BY - ZONE COOLNET ZONE (band) FREE ZONE Set-Point Coolnet C Return air temperature cool net rcgroupairconditioning MIN FETURES COOLNET is a software that applies to chilled water air conditioners X TYPE, NEXT EVO CW and COOLROW CW microprocessor control system. It optimizes the LOD SHRING working mode and maximizes the energy savings. FUNCTIONL ND OPERTING CHRCTERISTICS Manages up to 15 units in LN, to optimize the temperature statistics. More than 15 units can be managed in groups. Minimizes power consumption, controlling uniformly units within the cooling zone. Increases energy saving of the units by a factor up to 40% when compared with BC standard solution. voids the heating/cooling fighting. The units work together to efficiently satisfy thermal load. Optimizes the answer to unbalanced load through a smart self-adaptive LOD SHRING. The master unit, through the application of heuristic algorithm, elaborates the average return temperature of all of the linked units and defines a Cooling Zone. It then processes the common load signal that modulates the fan speed of all the units within the operating band. MIN BENEFITS Represents an RC Group offer extension for the IT cooling market segment. nswers to the main needs of the XXI century Data Center: - Lower energy consumption. Savings on bills. - Management of unbalanced load. - Flexibility. daptability to the IT equipment evolution. - Ease of use. Simple parameters to be set, just turn on Cool Net function fiftycoolyears RCGROUP Sp G_ITC_RCW_

198 RC Cloud Platform RC CLOUD PLTFORM RILHEV: Performance and quality remote monitoring. GPRS solution for unattended monitoring. rc cloud platform rcgroupairconditioning MIN FETURES RC CLOUD PLTFORM is the most advanced solution in unattended monitoring and remote management for an air conditioning plant. Rilheva is able to analyse any physical quantity variation through RTU Modbus protocol on RS485 network and transmits the data detected to a control server. Each device can manage up to 31 units (a/c units/chillers) for a total of 400 Modbus Registers. Thanks to a simple web access (PC, Tablet or Smartphone), has an interface available that allows him to directly operate on the field. MIN BENEFITS FOR THE END USERS Constant monitoring of the plant. The system has the function to prevent a possible unit stop. Reception of warning signal in case of crossing of some critical parameters. MIN FUNCTIONS Check of the plants status in real time. nalysis in real time of each unit data. Possibility to receive, for each single set parameter, specific warnings in the preferred technology: SMS, Mail, Speech Synthesis, FX and push notification on PP (ndroid and ios). Creation and export of charts with historical data. Data monitoring directly on a geographical map Control transmission to the unit (start/stop, set point modification, alarms reset). Integration of different peripheral units in the system (pumps, movie camera, etc.). Logos, Trade Marks and Companies Name are property of respective Owners 198 G_ITC_RCW_8.4 RCGROUP Sp fiftycoolyears

next NEXT EVO CW kw UP FLOW DOWN FLOW CHILLED WATER E C CLOSE CONTROL AIR CONDITIONERS FOR CHILLED WATER FEEDING,

next NEXT EVO CW kw UP FLOW DOWN FLOW CHILLED WATER E C CLOSE CONTROL AIR CONDITIONERS FOR CHILLED WATER FEEDING, next CLOSE CONTROL AIR CONDITIONERS FOR CHILLED WATER FEEDING, NEXT EVO CW WITH UPFLOW OR DOWNFLOW AIR DELIVERY 6 261 kw CHILLED WATER E C UP FLOW DOWN FLOW 2 next evo cw INTRODUCTION The NEXT EVO CW series

More information

2013 Product Range Precision Air Conditioners (CRAC)

2013 Product Range Precision Air Conditioners (CRAC) 2013 Product Range Precision Air Conditioners (CRAC) 2013 Product Range RC Group air conditioners range CLOSE CONTROL AIR CONDITIONERS 2,0-244,0kW HEAT PUMP AIR CONDITIONERS 6,3-113,0kW 6,3-101,0kW AIR

More information

AIR CONDITIONERS. RCGROUP SpA fiftycoolyears C_GNR_0113

AIR CONDITIONERS. RCGROUP SpA fiftycoolyears C_GNR_0113 13 AIR CONDITIONERS RCGROUP SpA 19632013 fiftycoolyears 14 19632013 fiftycoolyears RCGROUP SpA 15 NEX EXT 6,4 108 kw R410A E C A C UP FLOW DOWN FLOW RCGROUP SpA 19632013 fiftycoolyears 16 NEXT close control

More information

unico turbo fl kw R134a MICRO CHANNEL OIL FREE INVERTER FLOODED CLASS E C Energy Class RCGROUP SpA fiftycoolyears C_GNR_0113

unico turbo fl kw R134a MICRO CHANNEL OIL FREE INVERTER FLOODED CLASS E C Energy Class RCGROUP SpA fiftycoolyears C_GNR_0113 tu 137 IR COOLED Liquid chiller equipped with oil-free centrifugal compressors with magnetic levitation bearings, flooded evaporator and microchannel CONDENSING coils 280 1500 kw Energy Class More efficient

More information

NEXT DL NEXT DL. rcgroupairconditioning

NEXT DL NEXT DL. rcgroupairconditioning NEXT DL: Close control air conditioners with displacement air delivery with remote condenser, or built in water cooled condenser or for chilled water feeding Cooling capacity: 7,7 51,4 NEXT DL rcgroupairconditioning

More information

UNICO TURBO FL FREE UNICO TURBO FL FREE HIGHEFFICIENCY INVERTER ACLASS FREECOOLING LOWNOISE. rcgroupairconditioning

UNICO TURBO FL FREE UNICO TURBO FL FREE HIGHEFFICIENCY INVERTER ACLASS FREECOOLING LOWNOISE. rcgroupairconditioning : Packaged air cooled liquid chillers with free-cooling system in class energy efficiency for outdoor installation, equipped with oil-free centrifugal compressors with magnetic levitation bearings, flooded

More information

rcgroup.it Flooded evaporator Refrigerant charge HFO1234ze, GWP<1 Low noise Minimum starting current EER up to 5,41 ESEER up to 9,10

rcgroup.it Flooded evaporator Refrigerant charge HFO1234ze, GWP<1 Low noise Minimum starting current EER up to 5,41 ESEER up to 9,10 Packaged water cooled liquid chillers in class energy efficiency for indoor installation, equipped with turbo oil-free compressors. Cooling Capacity: 250 1240 Flooded evaporator Refrigerant charge HFO1234ze,

More information

rcgroup.it Flooded evaporator Low noise Minimum starting current EER up to 5,25 ESEER up to 8,88

rcgroup.it Flooded evaporator Low noise Minimum starting current EER up to 5,25 ESEER up to 8,88 Packaged water cooled liquid chillers in class energy efficiency for indoor installation, equipped with turbo oil-free compressors. Cooling Capacity: 280 1840 Flooded evaporator Low noise Minimum starting

More information

unico turbo FL unico turbo FL LOW NOISE A-CLASS INVERTER rcgroupairconditioning

unico turbo FL unico turbo FL LOW NOISE A-CLASS INVERTER rcgroupairconditioning : Packaged air cooled liquid chillers in class energy efficiency for outdoor installation, equipped with oil-free centrifugal compressors with magnetic levitation bearings, flooded evaporator and microchannel

More information

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw COOLROW Close control air conditioners for In-Row installation Cooling Capacity: 14 61 Available in versions equipped with: - BLDC inverter scroll compressor on board of the unit - Chilled water feeding

More information

GLIDER EVO CLA GLIDER EVO CLA HIGHEFFICIENCY ACLASS. rcgroupairconditioning

GLIDER EVO CLA GLIDER EVO CLA HIGHEFFICIENCY ACLASS. rcgroupairconditioning GLIDER EVO CL GLIDER EVO CL: Packaged air cooled liquid chillers in class energy efficiency for outdoor installation, equipped with screw compressors and axial fans Cooling Capacity: 282 1513 HIGHEFFICIENCY

More information

unico pf unico pf rcgroupairconditioning

unico pf unico pf rcgroupairconditioning : ckaged air cooled liquid chillers for indoor installation, equipped with scroll compressors and plug fan Cooling Capacity: 19,6 264 unico pf PLTE rcgroupairconditioning R410 E C MIN FETURES ir cooled

More information

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning Industrial PYXIS CL: Packaged air cooled liquid chillers in class energy efficiency for outdoor installation, equipped with scroll compressor and microchannel condensing coils Cooling Capacity: 108 876

More information

glider evo cla glider evo cla A-CLASS rcgroupairconditioning

glider evo cla glider evo cla A-CLASS rcgroupairconditioning Industrial GLIDER EVO CL: Packaged air cooled liquid chillers in class energy efficiency for outdoor installation, equipped with screw compressors and axial fans Cooling Capacity: 284 1513 -CLSS rcgroupairconditioning

More information

PYXIS U PYXIS U. rcgroupairconditioning

PYXIS U PYXIS U. rcgroupairconditioning Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 44 284 rcgroupairconditioning MIN FETURES

More information

pyxis u pyxis ua NEW rcgroupairconditioning

pyxis u pyxis ua NEW rcgroupairconditioning Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 44,9 200,0 rcgroupairconditioning R410 C PLTE

More information

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning : Packaged air cooled liquid chillers with free-cooling system for outdoor installation, equipped with screw compressors and axial fans Cooling Capacity: 314 1343 Free-Cooling Capacity: 308 938 GLYCOL

More information

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB 4,5 22,5 kw Air-conditioned server-racks for direct installation into the room technicalcatalogue T_CLSEVO_0113_GB INDEX HIGHLIGHTS... 3 PLANT TYPE... 3 GENERAL CHARACTERISTICS... 5 SERIES IDENTIFICATION...

More information

GLIDER EVO GLIDER EVO. rcgroupairconditioning

GLIDER EVO GLIDER EVO. rcgroupairconditioning : Packaged air cooled liquid chillers for outdoor installation equipped with screw compressors and axial fans Cooling Capacity: 300 1313 rcgroupairconditioning R134a SHELL C MIN FETURES ir cooled liquid

More information

pyxis hp "u" pyxis hp "u" IDEA NEW rcgroupairconditioning

pyxis hp u pyxis hp u IDEA NEW rcgroupairconditioning Comfort PYXIS HP U : ir / water reversible heat pumps for outdoor installation, equipped with scroll compressors and axial fans Cooling Capacity: 42,3 195,0 Heating Capacity: 47,1 222,0 NEW IDE R410 rcgroupairconditioning

More information

FRIGO SCREW CLA PLUS Packaged water cooled liquid chillers in A+ class energy efficiency for indoor installation. Cooling Capacity: kw

FRIGO SCREW CLA PLUS Packaged water cooled liquid chillers in A+ class energy efficiency for indoor installation. Cooling Capacity: kw Packaged water cooled liquid chillers in + class energy efficiency for indoor installation. Cooling Capacity: 625 1179 kw Screw compressors Shell and tube heat exchangers Double refrigerant circuit EER

More information

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw Multifunction chillers for indoor installation. Cooling Capacity: 22 222 Heating Capacity: 25 236 Scroll compressors EC Plug Fans Plate type heat exchangers EER up to 3,12 COP up to 3,84 ESEER up to 4,01

More information

turb new unico turbo frigo turbo fl Liquid chiller equipped with magnetic levitation twostage centrifugal compressors RCGROUP SpA C_GNR_0711

turb new unico turbo frigo turbo fl Liquid chiller equipped with magnetic levitation twostage centrifugal compressors RCGROUP SpA C_GNR_0711 89 TURBO turb Liquid chiller equipped with magnetic levitation twostage unico new frigo fl cooling capacity 260,0 1524,0 kw compressors centrifugal refrigerant R134a fan type axial (UNICO series) microprocessor

More information

pyxis pyxisa NEW rcgroupairconditioning

pyxis pyxisa NEW rcgroupairconditioning Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 119,0 808,0 PLTE C rcgroupairconditioning

More information

kw. technicalcatalogue

kw. technicalcatalogue Packaged air cooled liquid chillers for outdoor installation equipped with oil-free centrifugal compressors with magnetic levitation bearings, flooded evaporator and microchannel condensing coils. 280

More information

KELVIN Clim F497. Kelvin air conditioning

KELVIN Clim F497. Kelvin air conditioning KELVIN Clim F497 Cooling Capacity: 400 ~ 1260 kw Free-Cooling Capacity: 497 ~ 1492 kw Packaged air cooled liquid chillers with free-cooling system in A class energy efficiency for outdoor installation,

More information

IT COOLING CLOSE CONTROL AIR CONDITIONERS PRECISION AIR CONDITIONERS WITH INVERTER TECHNOLOGY FOR STABLE ROOM CONDITIONS

IT COOLING CLOSE CONTROL AIR CONDITIONERS PRECISION AIR CONDITIONERS WITH INVERTER TECHNOLOGY FOR STABLE ROOM CONDITIONS IT COOLING CLOSE CONTROL AIR CONDITIONERS PRECISION AIR CONDITIONERS WITH INVERTER TECHNOLOGY FOR STABLE ROOM CONDITIONS IT COOLING CLOSE CONTROL AIR CONDITIONERS Extreme precision in temperature and humidity

More information

GLIDER_. air cooled liquid chilled chillers / heat pumps

GLIDER_. air cooled liquid chilled chillers / heat pumps GLIDER_ cooling capacity 189,7 1613,1 heating capacity 203,1 1613,1 compressors screw refrigerant R134a fan type axial microprocessor MP.COM models 45 RC GROUP SpA C_GNR_0507 87 VERSIONS : GLIDER (R134a)

More information

next evo cw next evo cw rcgroupairconditioning

next evo cw next evo cw rcgroupairconditioning : Close control air conditioners for chilled water feeding with upflow or downflow air delivery Cooling Capacity: 6,2 248,0 rcgroupairconditioning E C CHILLED WTER UP FLOW DOWN FLOW MIN FETURES Chilled

More information

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB T_SMT_0609_GB 4,9 49,5 kw Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans INDEX SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3 CE CONFORMITY... 3 WORKING

More information

Next MTR kw. technicalcatalogue. Air conditioners for Metrology Labs with upflow air delivery T_NXTMTR_0511_GB

Next MTR kw. technicalcatalogue. Air conditioners for Metrology Labs with upflow air delivery T_NXTMTR_0511_GB 6 15 kw Next MTR Air conditioners for Metrology Labs with upflow air delivery technicalcatalogue T_NXTMTR_0511_GB INDEX GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3

More information

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning : Direct expansion close control air conditioners with up-flow or down-flow air delivery. Cooling Capacity: 7 102 NEW SOFTWARE R410A rcgroupairconditioning E C A C UP FLOW DOWN FLOW MAIN FEATURES Precision

More information

kw COOLING kw HEATING

kw COOLING kw HEATING Heat pump water/water liquid chillers for indoor installation. Inversion on hydraulic circuit. 394 1505 kw COOLING 477 1976 kw HEATING technicalcatalogue T_FRGSCRWP_0913_GB INDEX GENERAL CHARACTERISTICS...

More information

nemo 5,4 30,5 kw 6,4 37,4 kw R410A PLATE water cooled chillers / heat pumps and motoevaporating units COOLING HEATING

nemo 5,4 30,5 kw 6,4 37,4 kw R410A PLATE water cooled chillers / heat pumps and motoevaporating units COOLING HEATING 171 water cooled chillers / heat pumps and motoevaporating units COOLING HEATING R410A 1 96 3 2 0 1 3 f i f t y c o o l y e a r s RCGROUP SpA 19632013 fiftycoolyears PLATE 5,4 30,5 kw 6,4 37,4 kw 172 VERSIONS

More information

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB R407C EASY_R Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans 5,2 41,5 kw T_ESY_R_0508_GB EASY_R R407C INDEX WORKING LIMITS... 3 SERIES IDENTIFICATION... 4 MODEL

More information

Be sustainable while protecting your business

Be sustainable while protecting your business Be sustainable while protecting your business Aquaflair 50Hz Air-cooled chillers and free-cooling chillers with double screw compressors and HFO R1234ze refrigerant (400V/3ph/50Hz) 300-1000 kw Aquaflair

More information

frigo turbo FL Chillers

frigo turbo FL Chillers frigo turbo FL FRIGO TURBO FL Packaged water cooled liquid chillers in A class energy efficiency for indoor installation, equipped with oil-free centrifugal compressors with magnetic levitation bearings,

More information

Kelvin air conditioning. KELVIN Clim W280. Cooling Capacity: 280 ~ 1840 kw

Kelvin air conditioning. KELVIN Clim W280. Cooling Capacity: 280 ~ 1840 kw Cooling Capacity: 280 ~ 1840 kw Water cooled liquid chillers in A class energy efficiency for indoor installation, equipped with oil-free centrifugal compressors with magnetic levitation bearings, flooded

More information

Kelvin air conditioning. KELVIN Clim W250. Cooling Capacity: 250 ~ 1240 kw

Kelvin air conditioning. KELVIN Clim W250. Cooling Capacity: 250 ~ 1240 kw Cooling Capacity: 250 ~ 1240 kw Water cooled liquid chillers in A class energy efficiency for indoor installation, equipped with oil-free centrifugal compressors with magnetic levitation bearings, flooded

More information

SA 1 INDEX Available versions...pag. 4 Structure of electro-galvanized and painted steel sheet...pag. 5 Ecological refrigerant R410A...pag. 5 Scroll compressors...pag. 6 Condenser coils...pag. 6 Brazed

More information

H4T R410A. refrigerant

H4T R410A. refrigerant H4T INDEX Polyvalent unit working modes...pag. 4 Available versions...pag. 4 Structure of electro-galvanized and painted steel sheet...pag. 5 Ecological refrigerant R410A...pag. 5 Scroll compressors...pag.

More information

1

1 ST www.coldinnovation.it 1 INDEX Available versions...pag. 4 Structure of electro-galvanized and painted steel sheet...pag. 5 Ecological refrigerant R410A...pag. 5 Scroll compressors...pag. 6 Condenser

More information

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS Energy saving thanks to a total recovery p Cooling Heating/DHW h Galletti multi-purpose heat pumps are total recovery units used for a simultaneous hot and

More information

gforce Units Data Aire and Data Temp Series

gforce Units Data Aire and Data Temp Series gforce Units gforce gforce is the most advanced mission critical cooling equipment available on the market today. These units are the most efficient and economical while complying with strict environmental

More information

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW Row Cooling Precision Air Conditioner Cooling Capacity: 26.2kW~68.6kW CHILLROW is installed closely with the server cabinets and refrigerating independently. The

More information

NEMO A Split-system liquid chillers for indoor installation. Cooling Capacity: 5 26 kw

NEMO A Split-system liquid chillers for indoor installation. Cooling Capacity: 5 26 kw Split-system liquid chillers for indoor installation. Cooling Capacity: 5 26 Built-in pumping group Scroll compressor Plate type heat exchanger EER up to 2,88 rcgroup.it Chillers : Motoevaporating units

More information

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series Type of Compressors Compressor Rotary Scroll Reciprocating Screw Centrifugal Air Cooled Chiller 77 ~ 329TR (270 ~ 1156 kw) ACDX Series 100 ~ 520TR

More information

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB Next P 6 112 kw COOLING 5 93 kw HEATING Heat pump air conditioners with upflow air delivery technicalcatalogue T_NXTP_0411_GB INDEX GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 4 MODEL IDENTIFICATION...

More information

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw COMFORT CHILLERS AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com COMFORT CHILLERS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air-cooled liquid chiller for outside installation

More information

Aquaflair TRAC-TRAF-TRAH

Aquaflair TRAC-TRAF-TRAH Aquaflair TRAC-TRAF-TRAH 110 400 kw Air-cooled chillers, free-cooling chillers and heat pumps for mission critical applications Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors

More information

Flexible & Innovative. Cooling Solutions

Flexible & Innovative. Cooling Solutions Flexible & Innovative Cooling Solutions Flexible & Innovative Compu-Aire Inc. offers a variety of high performance precision cooling systems that can adapt to your application needs. With today s rapidly

More information

INVERTER SCROLL. LG Electronics Distributed by. Copyright 2017 LG Electronics. All rights reserved.

INVERTER SCROLL. LG Electronics     Distributed by. Copyright 2017 LG Electronics. All rights reserved. LG Electronics http://www.lg.com http://partner.lge.com Distributed by Copyright 2017 LG Electronics. All rights reserved. FEATURES & BENEFITS High Efficient Inverter Technologies EER 2.65 / COP 3.2 /

More information

nemo a hp rcgroupairconditioning R410A

nemo a hp rcgroupairconditioning R410A NEMO A HP: Motoevaporating heat pumps for indoor installation, equipped with scroll compressor and plate heat exchanger Cooling Capacity: 5,5 25,0 Heating Capacity: 6,4 29,3 nemo a hp PLATE rcgroupairconditioning

More information

Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw

Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to 1.99 kw Centrifugal compressor with magnetic levitation This is a miniaturized, highly innovative

More information

Air cooled industrial chillers

Air cooled industrial chillers Air cooled industrial chillers Main features R410A refrigerant Cooling capacity 5 175 kw Air cooled industrial chillers Models Versions HE High Efficiency Finned coil evaporators submerged in the storage

More information

Corporate Mission & 7 guiding Principles

Corporate Mission & 7 guiding Principles Corporate Mission & 7 guiding Principles The Corporate Mission of the Mitsubishi Electric Group is to continually improve its technologies and services by applying creativity to all aspects of our business.

More information

Multi-Denco. » Precision Climate Control. Air Conditioning & Heating. Multi-DENCO

Multi-Denco. » Precision Climate Control. Air Conditioning & Heating. Multi-DENCO Air Conditioning & Heating Multi-DENCO Multi-Denco» Precision Climate Control Promise Precision control is more than just an industry term, it is a promise. A promise we sustain using our extensive experience.

More information

Modular Air-cooled Chillers

Modular Air-cooled Chillers Modular Air-cooled Chillers High Seasonal Efficiency (HSE) version Cooling capacity 48-232 kw Trane Flex Series Modular air/water chillers with axial EC fans, inverter driven scroll compressors and microchannel

More information

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw Air cooled chillers with brushless oil-free compressors R-134a RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw External installation with very low sound level Cooling circuit with

More information

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB Packaged air cooled liquid chillers for outdoor installation 42 574 kw technicalcatalogue T_EGL_1012_GB INDEX EUROVENT CERTIFICATION... 3 GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION...

More information

PRODUCT GUIDE

PRODUCT GUIDE PRODUCT GUIDE 01.2017 Cooling Heating CHAPTER 1 AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS FOR RESIDENTIAL & LIGHT COMMERCIAL APPLICATION Power (kw) Page IACAK/II/WP 101.5 106 0 58 115 A CLASS energy efficiency

More information

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw COMFORT HEAT PUMPS AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw climaveneta.com COMFORT HEAT PUMPS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air to water heat pump for outdoor installation,

More information

Chillers EWAQ-E-/F- EWYQ-F- Air cooled multi-scroll chillers and heat pumps

Chillers EWAQ-E-/F- EWYQ-F- Air cooled multi-scroll chillers and heat pumps Chillers Air cooled multi-scroll chillers and heat pumps High efficiency values both in cooling and heating mode Extremely wide operating range, outside ambient temperatures up to 52 C One or two refrigerant

More information

next p dw next p dw rcgroupairconditioning

next p dw next p dw rcgroupairconditioning NEXT P: Heat pump air conditioners with upflow air delivery with built-in water/gas exhaustion heat exchanger Cooling Capacity: 7,5 7,0 Heating Capacity: 7, 04,0 A C rcgroupairconditioning R40A PLATE E

More information

21,8 222 kw COOLING 25,2 236 kw HEATING

21,8 222 kw COOLING 25,2 236 kw HEATING Air cooled multifunction chillers 21,8 222 kw COOLING 25,2 236 kw HEATING technicalcatalogue T_MLTPF_0413_GB INDEX GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3 WORKING

More information

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique

More information

recooler HP EQKR HEAT PUMP

recooler HP EQKR HEAT PUMP AIR COMFORT AIR TREATMENT 9566 GB 2016.03.17 recooler HP EQKR HEAT PUMP» TECHNICAL CATALOGUE 2 ReCooler HP EQKR Technical Catalogue Content ReCOOLER HP EQKR HEAT PUMP 3 product presentation. 3 applications.

More information

SmartCool i-drive Inverter Compressor. 5-83kW Up to 45% more cooling kw/m 2 * + + Up to 21% more cooling kw/m 2 **

SmartCool i-drive Inverter Compressor. 5-83kW Up to 45% more cooling kw/m 2 * + + Up to 21% more cooling kw/m 2 ** Precision Air Conditioning DX SmartCool i-drive Inverter Compressor 5-83kW + + Up to 45% more cooling kw/m 2 * + + Up to 21% more cooling kw/m 2 ** * compared to fixed speed compressor systems ** compared

More information

Conditioning your ambient, maximising your comfort.

Conditioning your ambient, maximising your comfort. High efficiency water cooled chillers, heat pumps and evaporating units with screw compressors and R134a refrigerant gas. Cooling capacity 378 1554 kw Heating capacity 425 1744 kw Cooling capacity evaporating

More information

INVERTER SCROLL INVERTER SCROLL INVERTER SCROLL. LG Electronics Distributed by

INVERTER SCROLL INVERTER SCROLL INVERTER SCROLL. LG Electronics     Distributed by 4mm 이상 ~ 15mm 미만 (음화형 규정) LG Electronics http://www.lg.com http://partner.lge.com Copyright 2017 LG Electronics. All rights reserved. Distributed by FEATURES & BENEFITS High Efficient Inverter Technologies

More information

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly. HITACHI proudly presents to our customers this wide range of split system air conditioners, from 4HP to 20 HP which is designed for high and medium outdoor temperature and comply with almost any types

More information

Chilled Water Precision Air Conditioner for Critical Application

Chilled Water Precision Air Conditioner for Critical Application AIRSYS-P-SC-OPTIMA-HD-E14507V01.3 HD Chilled Water Precision Air Conditioner for Critical Application Cooling Capacity: 42.1kW~180.9kW OPTIMA product family is designed for medium to large data center.

More information

Chillers case study. Children s Hospital of Medical University of Warsaw. The project, the analysis and the solutions produced by RC Group Spa

Chillers case study. Children s Hospital of Medical University of Warsaw. The project, the analysis and the solutions produced by RC Group Spa Chillers case study Children s Hospital of Medical University of Warsaw The project, the analysis and the solutions produced by RC Group Spa casestudy CS_14001_GB INDEX 1... INTRODUCTION... 4 2... THE

More information

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw PROCESS CHILLERS AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com PROCESS CHILLERS MAXIMUM EFFICIENCY IN EVERY TYPE OF PROCESS APPLICATION Air cooled liquid chiller for outdoor

More information

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION ECO-FRIENDLY REFRIGERANT GAS INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the result of many years

More information

SmartCool i-drive Inverter Compressor. 5-83kW Up to 45% more cooling kw/m 2 * + + Up to 21% more cooling kw/m 2 **

SmartCool i-drive Inverter Compressor. 5-83kW Up to 45% more cooling kw/m 2 * + + Up to 21% more cooling kw/m 2 ** Precision Air Conditioning DX SmartCool i-drive Inverter Compressor 5-83kW + + Up to 45% more cooling kw/m 2 * + + Up to 21% more cooling kw/m 2 ** * compared to fixed speed compressor systems ** compared

More information

ARV.

ARV. ARV www.coldinnovation.it 1 INDEX Available versions...pag. 4 Structure of electro-galvanized and painted steel sheet...pag. 5 Ecological refrigerant R134a...pag. 5 Semi-hermetic screw compressor...pag.

More information

next DX.U.S* 052.Z2.H6.DC

next DX.U.S* 052.Z2.H6.DC next DX.U.S* 05.Z.H6.DC GENERAL CHARACTERISTICS Air conditioning unit with remote air cooled condenser, for computer rooms, any high-tech facility and offices. Units can run non-stop at 4x65 hours a year.

More information

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications

More information

EQSL TECHNICAL CATALOGUE AIR COOLED WATER CHILLER UNITS AXIAL FANS. Models: 300 V2 F V2 F16. Cooling capacity: 299 to 1310 KW

EQSL TECHNICAL CATALOGUE AIR COOLED WATER CHILLER UNITS AXIAL FANS. Models: 300 V2 F V2 F16. Cooling capacity: 299 to 1310 KW TECHNICAL CATALOGUE EQSL Air Cooled Water Chillers Models: 300 V2 F06 1310 V2 F16 Cooling capacity: 299 to 1310 KW 02.16 ref. 207598 Rev.100 Thank you for trusting in Hitecsa Products. Our company has

More information

DAIKIN Modular Inverter Air Cooled Chiller

DAIKIN Modular Inverter Air Cooled Chiller DAIKIN Modular Inverter Air Cooled Chiller R410A ODP=0 R410A ODP=0 R410A ODP=0 R410A ODP=0 1 EVOLUTION ULTIMATE DAIKIN has achieved a wealth of world s firsts over the last three centuries. Based on four

More information

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz EN Technical Catalogue Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: 321-1308 kw 50 Hz EKV/BS business Air cooled water chillers for outdoor installation. Flexibility in the

More information

TurboChill Water Cooled 150kW kW*

TurboChill Water Cooled 150kW kW* Chiller Water cooled TurboChill Water Cooled 150kW - 1472kW* * based on 4 models + + ESEER up to 9.28 + + Class A EER up to 5.9 + + Up to 111% more cooling kw/m 2 * + + 3 module variants (R134a TT300 &

More information

Climate control precision in Hi-tech environments Jupiter and Mercury Close Control Units

Climate control precision in Hi-tech environments Jupiter and Mercury Close Control Units Climate control precision in Hi-tech environments Jupiter and Mercury Close Control Units Precision control from the total provide Uncompromised precision More than ever data centers, server rooms, and

More information

NRP MULTIPURPOSE HEAT PUMPS 2 AND 4-PIPE SYSTEMS PLUS PRODUCTION OF DOMESTIC HOT WATER

NRP MULTIPURPOSE HEAT PUMPS 2 AND 4-PIPE SYSTEMS PLUS PRODUCTION OF DOMESTIC HOT WATER NRP MULTIPURPOSE HEAT PUMPS AND 4-PIPE SYSTEMS PLUS PRODUCTION OF DOMESTIC HOT WATER Multipurpose air cooled units with axial fans. For external installation. High efficiency version. NRP MULTIPURPOSE

More information

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT AIR TREATMENT ReCOOLER HP ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT Energy efficiency the essence of our solutions All our research, development

More information

EN aquatech.piovan.com

EN aquatech.piovan.com EN aquatech.piovan.com Refrigeration Technologies: scroll-compressor chillers The scroll compressor is the most suitable component for the small and medium duty requirements in the industrial applications.

More information

coldpack water cooled chillers / heat pumps and motoevaporating units C_GNR_0508

coldpack water cooled chillers / heat pumps and motoevaporating units C_GNR_0508 coldpack water cooled chillers / heat pumps and motoevaporating units 133 134 COLDPACK VERSIONS : COLDPACK.W (R407C) Cooling capacity 32,2 513,0 Liquid chiller equipped with scroll compressor and built-in

More information

Galletti Water chillers and heat pumps catalogue

Galletti   Water chillers and heat pumps catalogue Galletti www.galletti.it Water chillers and heat pumps catalogue Table of Contents/SMALL SYSTEMS MPI DC Water chillers and heat pumps with inverter compressor 6 models page 6 MCE MPE Air condensed water

More information

PURESTREAM CHILL-CUBE TM BY FRIULAIR

PURESTREAM CHILL-CUBE TM BY FRIULAIR PURESTREAM CHILL-CUBE TM BY FRIULAIR Air-cooled water chiller Cooling capacity from 0.5 to 6 tons R407C Refrigerant QPS Inspection label certified to CSA standards 2 Year parts warranty The QBE Chill-Cube

More information

44,9 202,0 kw. technicalcatalogue

44,9 202,0 kw. technicalcatalogue Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressor and microchannel condensing coils 44,9 202,0 kw technicalcatalogue T_PYXU_0413_GB INDEX EUROVENT CERTIFICATION...

More information

OPERATING RELIABILITY AND CONTINUITY. HIGH SENSIBLE COOLING CAPACITY No latent cooling required.

OPERATING RELIABILITY AND CONTINUITY. HIGH SENSIBLE COOLING CAPACITY No latent cooling required. 1-16 broch telecom eng 6-02-2013 10:36 Pagina 1 TELECOMRANGE Units for mobile telecounication applications, split versions, indoor & outdoor packaged units, range from 1,5 20, with Free Cooling and the

More information

DATASHEET CoolTeg Plus CW CoolTeg Plus DX CoolTeg Plus XC

DATASHEET CoolTeg Plus CW CoolTeg Plus DX CoolTeg Plus XC DATASHEET CoolTeg Plus CW CoolTeg Plus DX CoolTeg Plus XC COMPARSION OF DIFFERENT DATA CENTER COOLING PRINCIPLES CoolTop CoolTeg Plus CRAC Cooling layout Above racks In row of racks Perimeter of the room

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 1402 C O K AIR R-407C Series RAE... C K Cooling capacity from 81 to 250 kw - 2 circuits The air cooled chillers of RAE C K series, with centrifugal fans, are designed for indoor installation and are

More information

Flexible and efficient: Close Climate Control for IT equipment

Flexible and efficient: Close Climate Control for IT equipment GEA Multi-DENCO Flexible and efficient: Close Climate Control for IT equipment engineering for a better world GEA Heat Exchangers GEA Multi-Denco at a glance: Multiple functions and applications High flexibility

More information

Air-cooled Screw Chillers Model RTAF G Process

Air-cooled Screw Chillers Model RTAF G Process Air-cooled Screw Chillers Model RTAF G Process Near 0 GWP (

More information

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES LS ir cooled water chillers with axial fans + LS The LS water chiller range has been designed for small and medium residential and commercial applications. They are suitable for generating chilled water

More information

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1 UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS GPE 802 Kc + CF + GP + MV + P1 130 Above picture is only indicative and is not binding. AIR R-410A

More information

RIGID DC LIQUID CHILLER

RIGID DC LIQUID CHILLER RIGID DC LIQUID CHILLER Phone: +86-579-8837-9768 Email:info@rigidhvac.com Website: www.rigidchill.com 1 1. WHAT S LIQUID CHILLER? Liquid Chiller cooling refers to cooling by means of the convection or

More information