Pro-1. Hi-Lo VIII. Hi-Lo Classic. Customize the Pro-1 to your bird size and feeding requirements. CUMBERLAND PAN FEEDING

Size: px
Start display at page:

Download "Pro-1. Hi-Lo VIII. Hi-Lo Classic. Customize the Pro-1 to your bird size and feeding requirements. CUMBERLAND PAN FEEDING"

Transcription

1 COMPLETE BROILER

2 CUMBERLAND PAN FEEDING Cumberland manufactures a variety of broiler pan feeder models to accommodate the specific needs of each and every grower. All of our broiler pan feeders represent a concept for taking birds from day old through adult. We can help build a system that provides the performance you need to maximize the return on your investment. The Ultimate Flood Pan Feeder... Care for your birds from day one through growout with the Pro-1* pan feeder. The Pro-1 offers unrivaled options for customization. Flood the feeder in its 2 collapsed position, or use the simple mechanism to lock it in as a deep pan and flood it at the 3.5 depth. Pro-1 Flood feeding windows Optional 2 to 3.5 collapsible/expandable pan accommodates bird size First in/first out feed level settings 8 spoke design for easy bird access Clear guard keeps chicks from entering the flood window Optional 2-piece drop tube Hi-Lo Pan Feeders Features Include... Multiple levels of feed depth control 2 to 3.5 collapsible/expandable pan accommodates bird size 8 or 14 spoke pan design for easy bird access 360 pan play reduces bruising and injury Exclusive feed saving design features Optional 2-piece drop tube * US Patent No. 7,647,888 Collapsed Flood Position with Window Guard Locked Flood Position with Window Guard Turn any existing Cumberland Hi-Lo feeder into a Pro-1 Broiler Pan Feeder with the PRO-1 RETRO KIT. Hi-Lo VIII Customize the Pro-1 to your bird size and feeding requirements. Hi-Lo Classic Pro-1 Retro-Kit Hi-Lo Feed Level & Feed Level Stand The drop tube and grill combination allow PLAY IN 360, reducing bruising and injury to the birds. 2 Collapsed Position 3.5 Locked Position The HI-LO TELESCOPING DROP TUBE automatically compensates for uneven floor conditions. The drop tube is available in either the standard one piece or optional two piece design. 2 3

3 FLOOD FEEDING WITH OPTIONS Cumberland s E-Feeder and Nutrapan flood feeders can easily be adjusted to fit your particular feed level requirements. Simple to install with plenty of customizable options make these feeders a flexible choice for flood feeding. Trouble Free with Cumberland s i-plus3 Control Pan Line utilizes Infrared Technology to sense and detect the level of feed in the control pan for proper and reliable operation, day in and day out. Infrared Technology requires no moving parts or sensitivity adjustments. PATENT NO. 8,915,214 NutraPan No spoke design provides uninhibited access to the pan Clear guard keeps chicks from entering the flood window Easy twist lock adjustment 6 levels of feed depth control Large 3.5 pan depth 2-piece drop tube Adjustable feed depth levels 14 spoke design for bird separation Optional 2-piece drop tube Durable all plastic design for long life and dependability Flood feeding windows Cumberland offers an OPTIONAL 2-PIECE DROP TUBE for easier in-line installation. A 2-piece drop tube is an available option for Cumberland s E-feeder and is a time saver when installing feeders on feed lines. Easy installation Certification applies to controls Low maintenance Easy to use with no moving parts or sensitivity adjustments Reliable feed sensing technology that promotes full pans and healthy birds to maximize feed conversions Power supply is included in the i-plus3 control pan for an optional LED light Cumberland offers a SELECTION OF CONTROL PANS for your feeder line. Choose from a micro switch, proximity switch or Cumberland s exclusive spinner motor control pan. All control pan models are durably constructed and assure consistent feed regulation. A durable plastic OVERFLOW BYPASS FUNNEL redirects any feed that may have escaped falling through the control pan drop tube conveniently back into the feed pan. Micro Switch Control Pan Spinner Style Control Pan Our NEW LINE OF FEEDING MOTORS are reliable, powerful, built to last and offer end users an overall better value for their dollar. These 50/60 hertz motors come with a two year warranty and feature improved starter switches which enhance reliability and longevity. Bleed resistors have been added to all motors with capacitors to reduce heat buildup for frequent start applications. An industry proven centrifugal actuator design has been incorporated into all single phase motors. An OPTIONAL HI-LO CONTROL PAN LED LIGHT is As the i-plus3 Control Pan available to stimulate fills, the infrared beams bird activity to the feed detect the feed level. line control pan. Where other systems utilize a directional light source mounted outside the control pan, Cumberland s light assembly attaches directly above the feed pan providing 360 of lighting coverage. When the feed level breaks all three of the infrared sensors, the auger will stop automatically. Easily retrofitted to existing Cumberland Hi-Lo control pans in the field Kit is factory assembled for ease of field installation Control pan light can be operated on 115VAC or 230VAC Substantial energy savings per year when compared to a standard 60 watt bulb The control pan LED light plugs directly into the power supply included in the i-plus3 Control Pan When the feed drops below the infrared sensors, the auger will re-start automatically after a 60 second delay. 4 5

4 CUMBERLAND EXCELLENCE in feeder technology extends to a line of pan accessories. Long life, easy cleaning and reliability adds to the overall pan feeding performance. Economical Feed Tray Chick Booster with Cone Chick Booster E-Chick Booster Heavy Duty Feed Tray It Just Makes Sense! The IR-Plus is specially designed to work hand and hand with Cumberland s Flex-Flo feed delivery system and i-plus3 Control Pan. This combination of dependable Cumberland products provide gentle feed handling, full hoppers and feed pans that will result in maximum feed efficiency. With no moving parts or sensitivity adjustments, the IR-Plus ensures the feed level switch is activated every time. When the feed level drops below the sensors and the user defined time delay has elapsed, the fill system will start, bringing feed to the desired hopper. Adjustable time delay prevents the fill system from short cycling, extending motor and auger life U.S. Patent 8,056,506 CUMBERLAND FEED TRAYS used with the Chick Booster, will provide the needed feed space in your broiler application. These Feed Trays are made of durable polypropylene for long life, easy cleaning, and dependability. Cumberland s CHICK BOOSTER AND E-CHICK BOOSTER are available with or without cone. The cone restricts the feed flow amount to feed trays for one uniform feeding and less crowding. Infrared sensors accurately detect feed flow to shut fill systems off when the hopper is full No moving parts or sensitivity adjustments for low maintenance, accurate feed levels every time Easy installation and retrofitable, adapts to nearly all flexible auger systems LED lights allow quick verification of operating status Light, durable, fully galvanized FEED LINE HOPPERS are available in 120, 200, 300 and 400 lb. capacity. Cumberland pan feeder accessories offer durability and reliable performance. The SENS-O-MATIC II FEED HOPPER SWITCH has proven to be a reliable way to regulate your feed delivery. An optional adjustable bracket kit allows the Sens-O-Matic to be conveniently adjusted to proper operation height. Heavy fabricated, galvanized, SINGLE AND DOUBLE OUTLET BOOTS are available for end or center house feeding applications. Traditional MICRO SWITCHES, PROXIMITY HOPPER LEVEL CONTROLS and FLEX-FLO HOPPER LEVEL CONTROL SWITCHES are available to regulate feed delivery. Standard Hopper Suspension STANDARD HOPPER SUSPENSION allows removal of the feed hopper without affecting the feed line suspension when raising the feed lines for clean out and normal maintenance that might occur between flocks. The optional FEED HOPPER ROTATION SUSPENSION KITS can be easily installed on existing or new feed lines allowing the feed hopper to rotate 90 degrees without removing the feed hopper. Optional Feed Hopper Rotation Suspension Kit The rib on Cumberland s LOCK FORMED TUBING gives added strength to the tube, as well as providing a solid way to hold the pans in place. The auger is manufactured from pre-flattened wire to reduce material stress and provide for a more consistent, high quality product. Proven & Dependable 6 7

5 QUALITY WATERING SYSTEMS Cumberland s experience and engineering continue to bring to you a complete watering system loaded with innovations and features that promote large healthy birds and dry floors. Cumberland s watering systems are engineered for easy installation, low maintenance, and cost saving operation. Cumberland s nipple drinker system includes the 360 side-to-side nipple valve toggle action, plus an increased flow rate with vertical lift action. END KIT Extra strong design Tall flexible sight gauge allows for easy pressure reading Garden hose drain AIR VENT Bleeds air from high spots Offers mid-line sight gauge reading Can be installed anywhere US Patent No. 7,090,261 Water Pipe Guide CONNECTIONS External sealing O-ring connection allows unobstructed water flow No glue necessary 1.05 (27 mm) large volume pipe Simple push together assembly Keyed connection from regulator to end assembly Light resistant water pipe prevents algae Water Pipe Notch SELF SEALING CAP at the clear sight tube to prevent water spillage Cumberland s unique WATER REGULATOR is designed for greater versatility and ease of use, no by-pass necessary. The Cumberland Regulator can be easily removed from the watering line without interfering with the watering line suspension. MID-LINE REGULATOR with its unique in-line design can be used as a mid-line regulator by simply removing the end cap SUPPORT SYSTEM OPTIONS Cumberland s aluminum rail joint connectors are easy to install and provide a robust fit for your connection needs. Aluminum Rail Round Pipe Convenient Manual Flush US Patent No. 6,712,021 Twin Lock/J-Lock Nipple Valves 6 different styles available to meet your watering needs Only 3 moving parts Four times easier action Stainless steel upper pin for long life and more precise flow rate Quick and easy assembly for Twin Lock (no wrench required) Valve Body - Left or Right Twin Lock Connection Twin Lock Upper Metering Pin - Controls Water Flow O-Ring Seal - Features Compress Seal Interchangeable Cap Stainless Steel Shut Off Ball Stainless Steel Seat Large Drinking Cavity Attracts Chicks Easy Action 360 Trigger Pin J-Lock Valve Body - Left or Right J-Type Lock Connection DRINKING CUPS The easy to install drink cup is available as an option on Cumberland s watering systems Nipple Flow Rates INCHES OF WATER COLUMN 8 9 ML/MIN Grey Nipple Green/Orange Nipple White Nipple Purple Nipple

6 Feathersoft Nipples The patented FeatherSoft Broiler Nipples are designed to meet the demands of today s broad poultry production needs. Choose between FeatherSoft Advantage Nipples and FeatherSoft Hi-Flow Nipples with LitterGard to design a system that best satisfies the needs of your unique broiler operation. 360º side action triggering Exact water metering at every age Simplistic design Square pipe advantage Trouble-free performance Corrosion resistant aluminum rails Simple and quick assembly Watering sections shipped completely preassembled One-Arm LitterGard Two-Arm LitterGard TECH TALK Number of Birds per Nipple FeatherSoft Advantage FeatherSoft Hi-Flow with LitterGard Nipples per 10 Section - Standard 10 nipples per 10 (3 m) Section 12 nipples per 10 (3 m) Section 15 nipples per 10 (3 m) Section Max. Recommended System Length 250 (80 m) per Regulator Water Pressure Requirement length Pressure Regulator: min. 20 psi (1.380 bars) max. 45 psi (3.103 bars) Radiant Tube Heat Allowing heat to be radiated directly to the birds allows them to find their own comfort zone either closer to, or farther away from, the heater. This reduces stress and creates an environment that allows for better bird performance. Heavy Duty control and burner unit, using outside air for combustion. The unique two stage burner adapts to varying conditions providing a more consistent comfort zone with fewer off cycles. Units operate at low fire the majority of the time for improved energy efficiency. High fire mode provides reserve heating capability when conditions require. The OptiGROW nipple is designed to work in today s challenging broiler environment. Because the nipple has been optimized for growth, you will be amazed by the first-week low mortality results and increased weight gains on jumbo birds. LOW THREAD PROTECTION Less restriction of water flow for better flushing INCREASED WALL THICKNESS Thick walls offer a more robust design and better chemical resistance LARGE BODY The large body provides better visibility HYGIENIC DESIGN The new nipple body helps keep the nipple clean EASY TRIGGERING Less triggering force gets dayold birds off to a fast start OptiGROW The Ultimate Broiler Nipple Optimized for Growth HYGIENIC SURFACE The smooth inner surfaces avoid deposits and provide minimal friction for easier triggering ACID-RESISTANT MATERIALS The special quality and grade of materials used provide the best protection against acid corrosion ADAPTER AREA Accessories can be directly attached to the nipple body LARGE DIAMETER PIN The large diameter of the pin holds a large water drop Patented Two-Stage Burner Two-Stage Technology Fuel savings Faster heat loss recoveries Improved comfort levels Reduction in equipment cycles Design protection benefits The Super-Saver and Tube Heaters are available in CE Certified models. Infra-red heat emulates the true efficiency of the sun. It generates energy that is converted into heat when absorbed by objects like floors and animals. The energy is then re-radiated to warm the surrounding area by convection. This is the most efficient method of heating many poultry facilities. RADIANT TUBE AG-1 OR AG-2 HEATER FEATURES 16 ga. aluminized combustion chamber - (1st 10 ) Turbulator baffle for maximum efficiency 4 overlapping slip-fit tube connections High efficiency polished aluminum reflectors Two mounting options: center or side mount Solid state silicon carbide ignition system Unique anti-rattle reflector springs 24 PVC coated stainless steel flex connector Ignitor changeable without tools Bolted tube clamps 2 x 4 electrical junction box Air inlet collar standard 100% enclosed components 1/2 gas cock provided Reflector end caps 10 11

7 DISTRIBUTE HEAT MORE UNIFORMLY AV Series heaters utilize separate upper and lower tube temperatures and a series of reflectors to distribute heat more uniformly throughout the building, creating and even comfort zone for birds. Just what are people saying about the AV Series Tube Brooder? The lower tubes are designed to distribute a lesser radiant energy resulting in reduced hot spots directly under the units and more uniform floor temperatures across the house. The U-bend at the end of the heaters have a separate end reflector directing the energy outwards, allowing optimum uniformity between units. The AV Series upper combustion tubes contain the flame and operate at higher temperatures. Each tube has its own reflector allowing the hotter upper combustion tubes to concentrate more energy to the perimeter of the heating pattern. Approximately 10% fuel savings; they produce a more even heat pattern; they heat up quicker, are quicker to setup; very satisfied with the heaters. John Holbert - Grower JCG Farms - Calhoun, GA Would highly recommend the AV heater. Preheat time is drastically reduced and it maintains a consistent and uniform floor temperature. We estimate 25% efficiency savings the 1st year. Paul Sanders - Grower Pilgrims - Athens, GA AV SERIES SPECIFICATIONS Most uniform heat I ve seen with very little maintenance and upkeep. Michael Cronic - Broiler Manager Columbia Farms, Lavonia, GA Growers are pleased with fuel savings, ease of maintenance, consistent heat patterns, and ability to pre-heat the house quicker. Mark Bellamy - Broiler Manager Pilgrims - Athens, GA AV Heaters have improved gas usage and chick uniformity. Heat patterns indicate floor temperature is maintained. Charlie Howington Broiler Manager Marjac Poultry - Gainesville, GA The AV Series Tube Brooder uses four tubes mounted in a V-Shaped pattern to direct the heat where it s most needed. No exposed flame to be effected by air flow or environment Totally enclosed electronics and burner system The highly polished aluminum reflectors allow optimum heat pattern for best uniformity Offered with Dual Stage Technology to maximize fuel efficiencies Low pressure system eliminates need for high pressure gas lines inside house Minimal assembly required Fresh air intake kit (attic version) with 4 x29 duct pipe, intake cap, chain hanging kit, and exhaust flapper cap are standard with each heater. Indicator lights display if unit is in low or high fire at a glance Easily access key components through an end service panel without having to remove the heater from suspension chains. Single Stage BTU: 80,000, Dual Stage BTU: 50,000-80,000 Option to direct vent Option to duct fresh air to unit to ensure clean combustion and reduce maintenance AV Series Heat Distribution - Infrared photos courtesy of Auburn University, National Poultry Technology Center (House pictured is 66 wide) Heating Capacity (Maximum per Hour) Direct Spark Ignition (3 Tries Before Lockout) 80,000 BTU 20,160 Kcal Maximum Gas Consumption LP.87 gph 3.29 l/h Natural Gas 75.5 cfh 2.14 m3/h Gas Pressure Requirements (Measured on Pressure Tap on Valve with Unit Running) LP Minimum 11.0 wc Maximum 14.0 wc NG Minimum 5.0 wc Maximum 14.0 wc Heater Size & Weight Information Weight Per Complete Unit 103 lbs. 47 kg Shipping Dimensions - Burner Box 31.5 L x W x T, Tube Box 91L x 31W x 14H Installed Dimensions (LxWxH) 107 x25.5 x13 272x65x33 (cm) Installation Guidelines Minimum Height from Floor (Measure from Floor to Bottom of Unit) 6-9 Feet Meters Space Between Heaters Feet Meters Minimum Clearance to Combustibles Sides of Heater cm Above Heater cm Below Heater cm Electrical Requirements AVD (Dual Stage) - 120v 60Hz GRD, 3 wire, 24vac thermostat connection AVS (Single Stage) -120v 60Hz GRD, 3 wire Starting Current amps Running Current amps Sensor Location Specifications * Sensor should be placed over the feed or drinker line. * Sensor should be no more than 12 to the side from the center of the unit and 10 length wise from the end of the unit

8 SUPER-SAVER XL HEATERS 250,000 BTU pilot light model features manual modulating valve (150, ,000 BTU s) Hot surface & direct spark models available in 40,000 to 250,000 BTU High temp aluminized steel burn chamber Side swing door for easy access and maintenance Diagnostic lights for troubleshooting ease Standard adjustable Y heat deflector 1/3 HP totally enclosed thermally protected motor with sealed bearings Available in 120 & 240 volt models. 1/10 HP on all 40,000 75,000 BTU models Standard ½ gas cock installed at gas valve Back-up safety sail switch High limit safety switch (manual reset) On/Off toggle switch Stainless steel, high altitude & CE certified models* available Service-Saver enclosed control box ACS DIRECT SPARK RADIANT BROODERS A consistent, stress-free environment promotes healthier, more productive animals. Radiant heaters provide a consistent, clean-burning and fuel-efficient source of warmth for all types of poultry houses. Aluminum canopy standard Stainless steel emitter assembly Unique, easy leveling, low profile, mounting bracket Stainless steel burner assembly with cast iron burner cap features large burner ports for years of trouble-free service Potted ignition control On/off switch Dual fuel gas valve The SERVICE-SAVER enclosed electrical control unit is sealed from debris such as dust and moisture and is accessible through a side swinging door making the unit easily field serviceable. The outside mount model is a forced air heater complete with all relevant installation hardware. The inside mount model is a gas circulating heater ideal for a confinement environment. Super-Saver pilot heaters available. A side swinging door design gives EASY ACCESS to internal components like the Super-Saver control unit and blower motor, making it one of the easiest to service heaters on the market. The ELECTRONIC HSI IGNITION is standard on all models. The heating chamber is made of high temp aluminized steel for superior rust protection. The cast iron burner is enamel dipped to eliminate dust adhesion and rust. The air intake surround increases combustion and heat change efficiency. Super-Saver XL Minimum Clearances Ceiling 12 (305mm) Wall 12 (305 mm) Floor 20 (508 mm) Heater must be positioned such that livestock and combustible materials are unable to come in contact with the heater or within 10 feet (3 meters) of the hot air discharge. SUPER-SAVER XL SPECIFICATIONS Model# Maximum Input Ventilation Voltage Amps SS-40-XL 40,000 BTUH (11.7kWh) 500 CFM (849.5 m³/hr) 120 Volts 2.5 Amps SS-75-XL 75,000 BTUH (21.9kWh) 500 CFM (849.5 m³/hr) 120 Volts 2.5 Amps HH-SS-120-XL 120,000 BTUH (35.2kWh) 1000 CFM (1699 m³/hr) 120 Volts 4.8 Amps HH-SS-175-XL 175,000 BTUH (36.6kWh) 1000 CFM (1699 m³/hr) 120 Volts 4.8 Amps HH-SS-200-XL 200,000 BTUH (58.6kWh) 1000 CFM (1699 m³/hr) 120 Volts 4.8 Amps HH-SS-225-XL* 225,000 BTUH (65.9kWh) 1000 CFM (1699 m³/hr) 120 Volts 4.8 Amps HH-SS-250-XL 250,000 BTUH (73.3kWh) 1200 CFM (2039 m³/hr) 120 Volts 6.0 Amps LP/Propane Gas Maximum 14 in. W.C. (34.8 mbar) and minimum 12.5 in. W.C. (31.1 mbar) inlet gas supply pressure acceptable at gas regulator connection. Burner manifold pressure of 11 in. W.C. (27.4 mbar) at maximum input. Gas pressure should be checked by a certified gas technician while heater is in operation. Natural Gas Maximum 14 in. W.C. (34.8 mbar) and minimum 5 in. W.C. (12.5 mbar) inlet gas supply pressure acceptable at gas regulator connection. Burner manifold pressure of 3.5 in. W.C. (8.7 mbar) at maximum input. Gas pressure should be checked by a certified gas technician while heater is in operation. *CE certified available in the HH-SS-225-XL Model Safety pan helps to shield litter directly under brooder AVS BROODER SPECIFICATIONS Model Number Gas Type FEATURES & BENEFITS The ZONE CONTROL PANEL allows you to control up to 30 brooders from one place. It also features a battery backup, four fused zone connections and one thermostat. Direct spark ignitor Enclosed potted ignition control protects components from humid and dusty environments 2 & 6 unit packaging combinations for transportational ease 3-try direct spark ignition before lockout On/off toggle switch for on the spot serviceability without engaging house controller Symmetrical heat pattern with reduced hot spots BTU/h Input Reflector Capacity Diameter Brooder Height Standard Weight Recommended Mounting Height* APPROVALS & CERTIFICATIONS: IAS U.S. Req. No CAN M85 Indoor (non-residential) approval Agricultural approval INPUT RATING: 40,000 BTU/H (11.72 kw) GAS TYPE: Natural or Propane Gas ACS-40P-120V Propane 40, lbs 5 to 6 3/8 NPT mm 120 VAC ACS-40N-120V Natural 40, lbs 5 to 6 3/8 NPT mm 120 VAC Gas Connection Manifold Pressure (Inches W.C.) Gas Orifice Size Primary Voltage Cumberland s durable THERMOSTAT ensures accurate, automatic operation and are moveable for your convenience Unit Total Amps Inlet Pressure ** (Inches W.C.)

9 MEGA FLOW BUTTERFLY FANS 36, 50, 52 and 54 Diameter Cumberland is proud to introduce the next generation of Mega Flow Butterfly Series Fans, re-engineered for improved air flow and greater efficiency. Available in 36, 50, 52 and 54 diameters, Mega Flow Butterfly fans are easy to install, extremely low maintenance and include many new features designed to save you time and money. GALVANIZED STEEL FANS All galvanized fans are constructed of heavy gauge, G-90 grade galvanized steel and use totally enclosed TEAO motors designed for high efficiency and continuous duty cycles. Front shutter doors offer protection while the fan is not in use from harsh weather conditions such as wind and moisture Arched side cone panels allow Cumberland fans to be mounted closer together on field installation Large pulleys allow for longer belt life and smooth operation. An automatic belt tensioner ensures proper belt tension Strong ring weldment with rod and V-channel vertical Air diverters for improved airflow Revised baffle spring attachments Neoprene baffle hinge for smooth, consistent operation Large, cast iron, high quality greasable pillow block bearings are used for longer life Bell or cage inlet options BUTTERFLY GALVANIZED FAN PERFORMANCE VALUES 0.0 Static Pressure.05 Static Pressure.10 Static Pressure.15 Static Pressure.20 Static Pressure BESS Lab Model Dia. Drive HP CFM CFM/Watt CFM CFM/Watt CFM CFM/Watt CFM CFM/Watt CFM CFM/Watt Test # IB 36 Belt NA IB 36 Belt IB 50 Belt C IB 50 Belt C IB 50 Belt C IB 52 Belt IB 52 Belt IB 52 Belt IB 52 Belt IB 54 Belt IB 54 Belt IB 54 Belt IB 54 Belt IB 54 Belt IB 54 Belt IB 54 Belt IB 54 Belt IB 54 Belt NOTE: Listed RPM at.10 static pressure. 36 AND 50 SLANTWALL FANS, in belt drive and direct drive models, efficiently and effectively maintain optimal environmental conditions. Galvanized fan propellers are aerodynamically balanced for maximum air flow. OPTIONAL DISCHARGE CONES can boost fan output by as much as 10-15%, greatly increasing efficiency. Made of all galvanized steel, cones are available in easy to ship and assemble four-piece segments for 36 & 50 models. Cumberland DIRECT DRIVE OR BELT DRIVE BOX FANS feature heavy duty galvanized steel housings, grill guards, venturis and propellers. Box fans are available in 36 (14 and 19 depth) or 50 (21 and 25 depth) diameters. SLANTWALL, SW CONE & BOX GALVANIZED FAN PERFORMANCE VALUES 0.0 Static Pressure.05 Static Pressure.10 Static Pressure BESS Lab Model Dia. Drive Type HP CFM CFM/Watt CFM CFM/Watt CFM CFM/Watt Test # CGSB36 36 Belt Slantwall G50SL16GA 50 Belt Slantwall CGSD36 36 Direct Slantwall CGSD50 50 Direct Slantwall CGBB Belt Box CGBB Belt Box CGBD Direct Box CGBD Direct Box CGSBC36 36 Belt SW Cone G50SCL16GA 50 Belt SW Cone G54SCL16GA 54 Belt SW Cone G54SCL16GHF 54 Belt SW Cone * Performance values of this fan at.05 static pressure exceeds the BESS Lab test capabilities and were calculated through regression analysis of CFM and CFM/Watt measurements

10 FIBERGLASS FANS Cumberland s fiberglass ventilation fans are manufactured using a Resin Transfer Molding (RTM) process for a smooth finish on both interior and exterior surfaces of the fan housing. The basic fan includes a heavy vinyl coated guard, PVC shutter, and all aluminum and stainless steel mounting hardware. Simple to install and built to last a lifetime 36 and 50 Performer Series fiberglass models available with and without cones When the design team at Cumberland was given the challenge of developing the PERFORMER SERIES fan line, three points were paramount. Performance, efficiency, and longevity all needed to be maintained while keeping the price as competitive as possible. You will find the Performer Series ventilation fans have not only met, but exceeded those goals. COMPOSITE PROPELLERS are made of a tough composite fiberglass. Engineered with a true airfoil design, these propellers increase the overall efficiency of the fan providing optimum airflow effectiveness. DRIVE SHAFTS of 1 material allow for large, cast iron, greasable pillow block bearings to be used for longer life. Large pulleys allow for longer belt life and smoother operation. FIBERGLASS FAN PERFORMANCE VALUES Cumberland s COMPETITOR SERIES fans are the airflow champions. Available in up to 54 models, harnessed with high efficiency motors, and capable of moving up to 30,000 cubic feet of air per minute, Competitor series fans are another powerful tool to help you compete in today s world marketplace. Features include a 1.5 HP single phase motor or a 1.75 HP three phase motor, easy belt access, fiberglass housing and cone, and stainless steel hardware. The belt driven 54 competitor series fans offer an AUTOMATIC BELT TENSIONER providing smooth operation and constant belt tension. Like all Cumberland belt drive fiberglass fans, cast iron pulleys and greasable pillow block bearings are standard features. 0.0 Static Pressure.05 Static Pressure.10 Static Pressure BESS Lab Model Dia. Drive Cone HP CFM CFM/Watt CFM CFM/Watt CFM CFM/Watt Test # APPB Belt No APPB-36C 36 Belt Yes APPB Belt No APPB-50C 50 Belt Yes CS54C1-P 54 Belt Yes Factory assembled, pre-wired, 20 CIRCULATION FANS are available for light air movement. These highly efficient 20 fans include 1/10 HP TEAO motors and galvanized props for whisper quiet operation. Other features include PVC coated guards for durability and multi-application hanging bracket. Choose from our long-standing, 3-bladed fan with standard grill spacing, or economical 2-bladed fan, with a wider spaced grill. LOW MAINTENANCE SHUTTERS 2-Bladed Circulation Fan Cumberland shutters can provide an easy and affordable means of controlling incoming light and building climate. PVC SHUTTERS come in white or black, and are very low maintenance and easy to clean. GALVANIZED SHUTTERS have galvanized frames, with epoxy painted blades to reduce rusting, allow easy cleaning and provide additional protection. ALUMINUM SHUTTERS offer great durability in any environment. 3-Bladed Circulation Fan Available in a variety of sizes and materials, we have a FAN SHUTTER to fit your particular requirements be it low light, low maintenance or low cost. The true airfoil design of our shutter blades make them extremely effective allowing for very little performance loss

11 Protect the health of your investment with a properly controlled curtain system. Cumberland s curtain machines deliver powerful performance and reliable operation with durable components to withstand a rigorous environment. Composite load nut offers increased life expectancy over brass. CURTAIN CONTROLLER Cumberland s Curtain Controller is a screw driven automated curtain machine with a heavy duty 15, 30 or 60 RPM motor. Multidirectional, frame mounted, header pulleys and latch out assembly come standard. A plastic water resistant junction box is accessible from the outside of the curtain controller. The drive block assembly features a removable nylon insert in a heavy-duty cast iron drive block simplifying cable/chain installation and ease of maintenance. This design also decreases friction and provides wear characteristics superior to conventional brass drive blocks. UHMW polyethylene guide wheels insure smooth travel, proper alignment and stability. Solid construction and rust resistant materials make the sprocket controller a reliable workhorse year after year. The Curtain Controller utilizes a threaded block and drive screw directly coupled to a direct drive gear motor. Operate attic inlets, vent doors, and other items requiring a 12 or less controlled movement at, or under, a 2,000 lb. capacity with the PowerTrak Vent Machine. Designed for a wall or ceiling mounted indoor installation, this machine will provide a more cost effective way to operate your vent inlet applications. The PowerTrak Vent Machine is available in 15 or 30 RPM models and can be ordered in either 120v or 240v single phase units. (Note: 240v units available in 50/60hz) Machine designed specifically for vent inlet applications 15 or 30 RPM - 120v, 60hz, 1ph 30 RPM - 240v - 50/60hz, 1ph 42.5 overall machine length for tight areas or short walls. Maximum travel length on rod is 12 Threaded block/drive screw directly coupled to DD gear motor Hardware included for cable or chain connection The door hinges from the top of the cabinet on a ceiling mount or can be easily removed on a wall mount for unobstructed access to components. Channel lock trakdrive system captures load block Easy adjust spring-cam limit switch system Isolated primary and secondary limit switches allow for backup protection. D Model H. P. Voltage Frequency AMP Draw Travel Speed RPM 15 RPM Curtain Controller 1/12 115V 60 Hz 1.0 Amps 3" per minute RPM Curtain Controller 1/8 115/220V 50/60 Hz 1.7 Amps 6" per minute RPM Curtain Controller 1/6 115V 60 Hz 1.8 Amps 12" per minute 60 A.T. Newell 1/2 115V 60 Hz 6.0 Amps 3" per minute 1725 Curtain Commander Length "A" Travel "B" Width "C" Length "D" Width Less Flange Weight 24" (61 cm) 22 (55.9 cm) 10.2 (25.9 cm) 52 (132.1 cm) 9.5 (24.1 cm) 110 lbs. (49.9 kg.) 36" (91.4 cm) 34 (86.4 cm) 10.2 (25.9 cm) 64 (162.6 cm) 9.5 (24.1 cm) 130 lbs. (58.9 kg.) 48" (121.9 cm) 46 (116.8 cm) 10.2 (25.9 cm) 76 (193 cm) 9.5 (24.1 cm) 150 lbs. (68.0 kg.) 60" (152.4 cm) 58 (147.3 cm) 10.2 (25.9 cm) 88 (223.5 cm) 9.5 (24.1 cm) 160 lbs. (72.6 kg.) A C With a 5,000 pound capacity, the superior quality and design of the PowerTrak linear drive system boasts many performance and durability enhanced features. Modular construction for ease of service. Built in head bracket with needle bearing pulleys. Channel lock trak-drive system captures load block. 15% increase in load block support surface for greater life. Easy adjust spring-cam limit switch system. Convenient, easily removable, hinged springlock door. Greater protection from the elements. Upper and lower auxiliary contact for enhanced Evolution features. B Cumberland s SIDEWALL VENT DOORS are used in poultry applications where transitional ventilation is required. HARDWARE KITS are available with heavy duty galvanized steel components including sealed needle bearing pulleys, and plated, anti-wrap designed fasteners for ease of installation. Part Number SWI-1700 SWI-2000 Description Curved Sidewall Vent w/plastic Door & Galvanized Frame Curved Sidewall Vent w/ Plastic Door & Galvanized Frame SP Rough Opening 2, x , x 46 The all plastic Curved Sidewall Vent Door directs fresh air into the house along the ceiling toward the peak for gentle air mixing without downdrafts on the birds. Also available in an all galvanized door construction, Cumberland vent doors are simple to install and provide years of optimum circulation

12 EASY INSTALL ATTIC VENTS Cumberland s Attic Vent ACI Series is precision engineered to extract solar heat from the attic space so it can be used as a valuable heat source. This unique and innovative design is cost effective, durable and easy to install. PVC Plastic Frame TUNNEL INLET DOOR SYSTEMS Tunnel inlets help to eliminate dead zone areas created by curtain sidewalls and curtain pockets. The Inlet Door System comes fully assembled and is a rigid laminate foam panel that is ultra lightweight for easy installation. Incorporating all of the same benefits of the ACI and ACI-4000 Series, Cumberland s PACI-2500 Series vents are pressure actuated and operated by constant force of static pressure controlled springs. The Attic Vent System is designed to be retrofit friendly in most drop ceiling poultry houses. Galvanized Frame With an insulation value of R-8, the SINGLE DOOR TUNNEL INLET provides excellent energy savings compared to conventional curtain inlets. Cumberland s single doors are comprised of lightweight rigid laminate foam panels and include a profiled rubber seal for an airtight fit. Single door tunnel inlets are available in 4, 5, & 6 heights and include two color options, black for dark out conditions, and white when dark out conditions are not required. Cumberland s FORMED RUBBER SEAL (profile shown right) provides an airtight seal. Molded runners make for easy alignment and quick installation. INLET DOOR FEATURES ADDITIONAL CUMBERLAND ATTIC VENT BENEFITS: Drier litter Lower ammonia concentration levels Better environment for the bird Easy Installation Lightweight Doors Energy Efficiency Low Maintenance End channels are prenotched for proper, quick and easy installation Offered in 4, 5, & 6 Heights Aluminum channels add rigidity to the door panels Available in two colors; Black or White Fully Assembled Part Number ACI-2500P2 ACI-2500GP2 ACI-4000P2 ACI-4000GP2 PACI-2500GP2 Description All Plastic Actuated Ceiling Inlet Actuated Ceiling Inlet (Galvanized Frame) All Plastic Actuated Ceiling Inlet Actuated Ceiling Inlet (Galvanized Frame) Plastic 2500 Pressure Actuated Attic Vent (Galvanized Frame) All Plastic 2500 Pressure Actuated Attic Vent Full Open 0.10 SP Horizontal 0.10 SP Framed Opening 2500 CFM 1700 CFM 19 W x 27 L 2500 CFM 1700CFM 21.5 W x 27 L 4000 CFM 2500 CFM 19 W x 46.5 L 4000 CFM 2500 CFM 21.5 W x 46.5 L 2100 CFM 1300 CFM 21.5 W x 27 L CURVED DOOR DESIGN directs air along the ceiling toward the house walls for gentle air mixing without downdrafts on the birds. Over time, cords can stretch requiring tension readjustment. Cumberland s easy adjuster makes insuring a reliable door seal a simple task. All brackets are galvanized for durability and long life. PACI-2500P CFM 1300 CFM 19 W x 27 L Mixing warm air from the attic with house air during minimum ventilation reduces fuel consumption as compared to using cold air through sidewall inlets. Fuel savings can vary depending on management, house construction and climate

13 EVAPORATIVE COOLING SYSTEMS Evaporative cooling systems The CLOSED TOP SYSTEM is extruded from ultraviolet stabilized utilize the natural cooling effect of PVC for durability and ease of installation. The hinge-open cover and evaporation to combat seasonal dips in production caused by heat stress. thumbscrews allows accessibility Made of high quality stainless steel or aluminum, the OPEN TOP SYSTEM offers the grower easy access to manage and maintain their evaporative cooling system. This systems design allows you to see the water jets and easily check water pressure. It also offers access to the spray bar for cleaning. to the spray bar and hold pads firmly in place. The spray bar bracket and water deflector insure pads are uniformly wet. Cumberland s PRE-FORMED SQUARE TROUGH serves as a 3 gallon per lineal foot (44.8 liters per meter) water reservoir. Constructed of corrosion proof, ultra-violet stabilized PVC components, the trough allows unevaporated water to be recirculated back to the holding tank. A perforated tray snaps to the trough to hold pads firmly in place. Injection molded end caps and couplers speed installation. JET PUMP FEATURES The Jet Pump System provides an external self priming pump. Trough mounted float valve eliminates the need for an external tank. The Permanent Split Capacitor motor eliminates the start switch and will mount to the wet end of any previous Jet Pump kit. Our Jet Pump System is field proven, reliable and a cost effective way to deliver water to Evaporative Cooling Systems. A roto-molded holding tank offers in creased water storage capacity. Center feed and drain kits are available for longer cooling systems. OTHER EVAPORATIVE COOLING SYSTEM FEATURES INCLUDE: Submersible pump keeps water levels consistent for efficient water delivery Automatic float valve for matching water supply with water demand Trough support brackets for suspending the system on a sidewall Wide selection of cooling pads Easy removal of pads for cleaning EVAP COOLING PADS Strongest & heaviest pad available Produced using the most advanced curing process Use the most advanced resin technology Superior black diamond edge coating Custom sizes from 2 to 6 tall. Made in the USA Cam-Lock system allows toolless pad installation and replacement. The spray bar bracket and water deflector insure pads are uniformly wet

14 ROLLSEAL DOORS To ensure optimal poultry health, you need to pay careful attention to maintaining the best possible environmental conditions. That means preventing drafts from entering and heat from escaping, making a RollSeal door the best decision for your operation. Suitable for any building, new or existing, RollSeal doors are easy to install and operate and provide years of worry-free environmental control. RollSeal creates a barrier that keeps the cold out and the warmth in so you know your investment is protected. UNITIZED ROLLSEAL SYSTEMS Cumberland s patented Rollseal Sidewall System is designed to fit the Komfort Kooler Evaporative cooling system with a precision tight fit to limit air infiltration. It utilizes 2 dead air spaces for the best insulating seal and protects cooling pads from inclement weather, dust, UV rays and other harmful environmental elements. Manual and automated drive options are available to best suit your application. SUPERIOR SEAL 3-LAYER PANEL PROTECTION 2 DEAD AIR SPACES TO IMPROVE INSULATION VALUE RS300 MODEL Suitable for all poultry applications Sizes up to 14 wide by 14 high Custom sizing available so you can find the door that fits your needs RS400 MODEL Ideal for larger applications Stronger aluminum channels, drive pipe and larger tension pipes to support longer doors Sizes up to 21 wide by 18 high OPTIONS INCLUDE: Additional switches and remote transmitter/receiver options available Fabric and window options Fabric color options PAD/SYSTEM PROTECTION FROM THE ELEMENTS ADAPTS TO KOMFORT KOOLER IN EITHER THE WALL MOUNT OR DIRECT TO CONCRETE VERSIONS MULTIPLE DRIVE OPTIONS TO BEST SUIT YOUR APPLICATION PATENTED TRIPLE - LAYERED EFFICIENCY Every state-of-the-art RollSeal door features a tough, tear-resistant patented three-ply fabric of inner and outer layers designed with a durable, long-lasting, hook and loop fastener seal. Each layer works together to provide an energy-efficient double seal, ideal for poultry ventilation applications. The upper drive shaft roller lifts and lowers the curtain by the central fabric layer By pushing the hook into the loop as the curtain is lowered, two offset lower tension roller bars create the side seal Tension rollers hold fabric against the floor for a proper seal Patented sealing system provides excellent wind load resistance Multilayered, high density, woven-polyethylene fabric has two air pockets that provide good thermal insulation Easy Install Easy Operation Installation couldn t be easier. Simply attach the strong and lightweight aluminum side channels to the head unit, stand the door upright to the frame, bolt the unit in place and you re done. Once installed, your RollSeal door is simple to maintain and easy to clean. When you open a RollSeal door, you ll see how quick and easy it is for anyone to operate the manual chain hoist or the motor drive. Tight Seal Mounting Brackets POWER DRIVE AVAILABLE IN v 1ph 208v 3ph 480v 3ph This product may be protected by one or more of the following patents: US , US , US , US , US , AU712128, BR , CA , CN325601, EP , IL124347, JP , MX204223, and NO

15 Cumberland is a part of GSI, a worldwide brand of AGCO Proven & Dependable P.O. Box 20; 1004 E. Illinois Street; Assumption, IL USA; Ph: 217/ ; USA Fax: 800/ ; Int l Fax: 217/ cumberland@cumberlandpoultry.com; Website: C-30 8/15 Copyright 2015 by AGCO Corporation Printed in USA Due to continual improvements, Cumberland reserves the right to change designs and specifications without notice.

Cumberland Heating Systems

Cumberland Heating Systems Cumberland Heating Systems Cumberland "Radiant" Brooder Clean Burning...Fuel Efficient Maintaining proper in-house temperature is critical in climate control. A consistent, stressfree environment promotes

More information

Breeder Pan Feeder. Pullet Feeder. Male Feeder

Breeder Pan Feeder. Pullet Feeder. Male Feeder COMPLETE BREEDER Breeder Pan Feeder Choose from 3 different styles of grills. Roosters restricted vertically and horizontally from accessing the hens feed. Durable plastic construction. Sturdy, all plastic

More information

Heating Systems. Brooders, Space Heaters and QuadRadiant Heaters

Heating Systems. Brooders, Space Heaters and QuadRadiant Heaters Heating Systems Brooders, Space Heaters and QuadRadiant Heaters Let s grow together. QUADRATHERM QuadRadiant Heater Patent Pending With Chore-Time s QUADRATHERM Heater, the Most Innovative Concept in Heating

More information

Heating Systems. Brooders, Space Heaters and QuadRadiant Heaters

Heating Systems. Brooders, Space Heaters and QuadRadiant Heaters Heating Systems Brooders, Space Heaters and QuadRadiant Heaters Let s grow together. QUADRATHERM QuadRadiant Heater SM Chore-Time s QUADRATHERM Heaters, Brooders and Space Heaters Offer Poultry Producers

More information

Greater temperature control

Greater temperature control Brighter glow Easy to clean and hang Increased floor heat features Greater temperature control Ignition options The Ultimate in Reliable, Efficient Radiant Heat Ultra-Ray Broad Comfort Zone Heats an average

More information

Brooders. Better Brooding for Your Chicks... Since 1924

Brooders. Better Brooding for Your Chicks... Since 1924 Brooders Better Brooding for Your Chicks... Since 1924 Bright, warm glow Increased floor heat Fuel efficient and durable Reliable ignition features Easy to clean and assemble Shenandoah s 42,000 and 40,000

More information

Chore-Time Fan Guide For Tunnel and Other Applications

Chore-Time Fan Guide For Tunnel and Other Applications Chore-Time Fan Guide For Tunnel and Other Applications Chore-Time s Fiberglass and Galvanized Fans Provide Efficiency and Performance Diameters available through 54 Inches (137.2 cm) Chore-Time s TURBO

More information

FORCED AIR HEATING VARIFLAME HEATERS

FORCED AIR HEATING VARIFLAME HEATERS FORCED AIR HEATING VARIFLAME HEATERS VARIFLAME HEATERS Variable Rate Heating with Less Hassle The VariFlame variable rate heater offers producers more control, easier access and increased longevity compared

More information

C u m b e r l a n d. S y s t e m s. Your Source for Innovative Solutions

C u m b e r l a n d. S y s t e m s. Your Source for Innovative Solutions Feed Systems Watering Environment C u m b e r l a n d Complete Turkey S y s t e m s Your Source for Innovative Solutions Feed Systems Turkey Pan Feeding Turkey Poult Feeder Cumberland s Plastic Turkey

More information

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Internal ridged board 1 x 1.5 foil face installation shall be installed on roof, walls and base of casing. A-D WITH MPU SPECIFICATION WRITTEN SPECIFICATION Description A Modular Packaged Heating, Cooling and ventilating unit(s), as indicated on the drawings shall be furnished. Direct Fired Gas Unit(s) shall

More information

Direct Fired Heater Model AD Specification

Direct Fired Heater Model AD Specification Direct Fired Heater Model AD Specification Description A Direct-fired gas heating and ventilating unit(s), as indicated on the drawings shall be furnished. Unit(s) shall be tested in accordance with ANSI

More information

and SHUTTERS Made to Work. Built to Last.

and SHUTTERS Made to Work. Built to Last. FANS and SHUTTERS Made to Work. Built to Last. VANGUARD PLUS Fan with HYFLO Shutter Chore-Time s VANGUARD PLUS Cone Fan provides a great combination of performance, features and value. Add Chore-Time s

More information

fans & heaters SIMPLE, ROBUST AND RELIABLE

fans & heaters SIMPLE, ROBUST AND RELIABLE FANS & HEATERS fans & heaters SIMPLE, ROBUST AND RELIABLE For over 50 years, NECO has specialized in agricultural equipment engineering and manufacturing. NECO produces market leading grain dryers and

More information

SHP High Pressure Radiant Gas Brooder Series

SHP High Pressure Radiant Gas Brooder Series January 23, 2015 For Immediate Release Editor Contact: Russ Burton, Burton Marketing, Charlotte Tel (704) 650-1880 e-mail rburton@burtonmarketing.com Space-Ray To Display For Pig And Poultry House Operations

More information

AGRI-AIDE Ventilation Equipment. AGRI-AIDE Ventilation Key to Unlocking...

AGRI-AIDE Ventilation Equipment. AGRI-AIDE Ventilation Key to Unlocking... AGRI-AIDE Ventilation Equipment AGRI-AIDE Ventilation Key to Unlocking... Osborne s world class ventilation equipment keeps indoor environments fresh and healthy for animals and the people who care for

More information

Cages for Laying Hens. Our Experience. Your Success. Count on Chore-Time for experience, reliability, performance and confidence.

Cages for Laying Hens. Our Experience. Your Success. Count on Chore-Time for experience, reliability, performance and confidence. Cages for Laying Hens Our Experience. Your Success. Count on Chore-Time for experience, reliability, performance and confidence. Modular Manure Belt (MMB ) Laying System 3-High to 12-High Systems Ultra

More information

FSA, FOA, SEP & HED Series Unit Heaters and Duct Furnaces

FSA, FOA, SEP & HED Series Unit Heaters and Duct Furnaces SG-UUH-03 November 2014 Specification Guide FSA, FOA, & HED Series Unit Heaters and Duct Furnaces Product improvement is a continuous process at Advanced Distributor Products. Therefore, product specifications

More information

Broiler Feeding System

Broiler Feeding System Broiler Feeding System The patent pending FLUXX broiler feeding pan system continues to set the standard in broiler feeding technology. The FLUXX system has been farm tested around the world, showing it

More information

Tradesman Tradesman K Norseman Workman Sun Blast Premier Foreman Torches. New

Tradesman Tradesman K Norseman Workman Sun Blast Premier Foreman Torches. New Tradesman Tradesman K Norseman Workman Sun Blast Premier Foreman Torches New TRADESMAN FORCED AIR LP/NG HEATERS Engineered to deliver reliable, directional heat, L.B. White Tradesman heaters feature a

More information

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas HVAC Guideline Specifications WHISPER-JET: SET SERIES Two Stage Positive Pressure Gas-Fired Infrared Radiant Tube Type Heater Commercial/Industrial Applications Technical Summary Input Range: 80,000/60,000

More information

GARAGE / WORKSHOP INFRARED HEATERS

GARAGE / WORKSHOP INFRARED HEATERS GARAGE / WORKSHOP INFRARED HEATERS 22,000-25,000 BTU/HR Heater For: Garages / Workshops Barns / Utility Buildings / Storage Sheds Animal Pens / Stalls Loading Docks Building Construction Sites Doorways

More information

Click Here To View Item at

Click Here To View Item at Click Here To View Item at www.gappower.com TRADESMAN FORCED AIR LP/NG HEATERS Engineered to deliver reliable, directional heat, L.B. White Tradesman heaters feature a unique 3-trial ignition system,

More information

SIOUX STEEL COMPANY GRAIN CONDITIONING EQUIPMENT. Fans, Heaters & Controls

SIOUX STEEL COMPANY GRAIN CONDITIONING EQUIPMENT. Fans, Heaters & Controls SIOUX STEEL COMPANY GRAIN CONDITIONING EQUIPMENT Fans, Heaters & Controls 1 GRAIN CONDITIONING EQUIPMENT SIOUX STEEL COMPANY Innovative Solutions Manufactured By A Family-Owned Company With A ENGINEERING

More information

TOWER DRYERS TOTA TOT L VA AL V LUE. TOTA ALUE. TOT L SYSTEMS. AL SYSTEMS.

TOWER DRYERS TOTA TOT L VA AL V LUE. TOTA ALUE. TOT L SYSTEMS. AL SYSTEMS. TOWER DRYERS TOTAL VALUE. TOTAL SYSTEMS. 1 GSI FEATURES 1 Gravity inlet does not require leveling auger, reducing the number of moving parts. 2 3 2 Self cleaning cushion box on plenum roof reduces grain

More information

Competitor Series Dryers

Competitor Series Dryers Cost Efficient, Competitively Priced, Completely GSI. Competitor Series Dryers "Your Complete Systems Manufacturer." THE COMPETITIVE EDGE GSI Competitor 100 Series grain dryers offer all the latest technological

More information

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS SECTION 15540 FUEL- FIRED HEATERS (Alternate - SECTION 235523 - GAS-FIRED RADIANT HEATERS) This section is based

More information

Day after day, Season after season, Generation after generation.

Day after day, Season after season, Generation after generation. FARM Bins Superior bins prove their strength and ability to protect crops from the harshest elements Day after day, Season after season, Generation after generation. There s nothing standard about Superior.

More information

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP CATALOG 9-117.1 JUNE, 2003 TABLE OF CONTENTS Modine's TLP Series sets the industry standard for low intensity infrared heating performance

More information

Burner Comparisons. Typical Competitor s Burner

Burner Comparisons. Typical Competitor s Burner Burner Comparisons INOV8 s Typical Competitor s Burner Automatic nozzle cleanout Yes No Available BTUs rated as input 100,000 to 1,000,000 76,500 to 500,000 Burner Motor - hp 1/5 1/7 Combustion safety

More information

Used Fluid Handling Portable Used Oil Gravity Drains

Used Fluid Handling Portable Used Oil Gravity Drains Portable Used Oil Gravity Drains Choose the fluid handling equipment that fits your needs. Traditional Drain: the traditional method for handling used fluids allows gravity to drain fluids from vehicle(s)

More information

REFLECTOR PANS FOR HINGED ELEMENTS CONNECTOR BLOCK KIT TRIM RINGS FOR ABOVE PANS CONNECTOR BLOCK RANGE CORD REFLECTOR PANS FOR PLUG-IN ELEMENTS

REFLECTOR PANS FOR HINGED ELEMENTS CONNECTOR BLOCK KIT TRIM RINGS FOR ABOVE PANS CONNECTOR BLOCK RANGE CORD REFLECTOR PANS FOR PLUG-IN ELEMENTS *s are Subject to Change without Notice.* REFLECTOR PANS FOR HINGED ELEMENTS Heavy Chromed Steel Description 2-1040 6" UNIVERSAL $2.19 2-1041 8" UNIVERSAL $2.89 2-1050 6" GE/HOTPOINT $2.39 2-1051 8" GE/HOTPOINT

More information

Competitor Series Dryers

Competitor Series Dryers Cost Efficient, Competitively Priced, Completely GSI. Competitor Series Dryers "Your Complete Systems Manufacturer." THE COMPETITIVE EDGE GSI Competitor 100 Series grain dryers offer all the latest technological

More information

Mi-T-M carries a full line of portable heaters, built in the same quality tradition you ve come to expect from us.

Mi-T-M carries a full line of portable heaters, built in the same quality tradition you ve come to expect from us. Why Mi-T-M? Mi-T-M space heaters deliver powerful instant heat right where you need it. Whether you require heat for your workshop, job site or any other outdoor setting these portable units can be moved

More information

Lubrication Tools and Equipment Portable Oil Drains

Lubrication Tools and Equipment Portable Oil Drains Portable Oil Drains Choose the fluid handling equipment that fits your needs. Traditional Drain: the traditional method for handling used fluids allows gravity to drain fluids from vehicle(s) into a portable

More information

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace TECHNICAL SPECIFICATIONS M3RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 90+ AFUE Input 60,000 & 80,000 Btuh The high efficiency downflow gas furnace is especially

More information

UNIT HEATER CATALOG. Form C-UH-0516 COMMERCIAL/INDUSTRIAL HEATERS RESIDENTIAL GARAGE HEATERS. FUEL Natural Gas Propane Fuel Oil

UNIT HEATER CATALOG. Form C-UH-0516 COMMERCIAL/INDUSTRIAL HEATERS RESIDENTIAL GARAGE HEATERS. FUEL Natural Gas Propane Fuel Oil UNIT HEATER CATALOG COMMERCIAL/INDUSTRIAL HEATERS RESIDENTIAL GARAGE HEATERS FUEL Natural Gas Propane Fuel Oil CAPACITIES 25-1,200 MBH 80% - 93% Thermal Efficiency 380-16,750 CFM AIR DELIVERY Propeller

More information

UNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F)

UNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F) UNIT HEATER CATALOG Form RZ-NA-C-UH (Version F) BACKGROUND Reznor was founded in 1888 to manufacture the Reznor reflector heater, which used a luminous flame gas burner developed by George Reznor. This

More information

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation Industrial Space Heating Direct Gas-Fired Heating Greenheat 00% Outdoor Air Greenheat 50/50 Recirculation 80/0 Recirculation March 008 Product Overview Industrial Space Heating Greenheck s space heating

More information

Used Fluid Handling Portable Used-Oil Gravity Drains

Used Fluid Handling Portable Used-Oil Gravity Drains Portable Used-Oil Gravity Drains Choose the fluid handling equipment that fits your needs. Traditional Drain: the traditional method for handling used fluids allows gravity to drain fluids from vehicle(s)

More information

GAS-FIRED HIGH INTENSITY INFRARED HEATERS

GAS-FIRED HIGH INTENSITY INFRARED HEATERS GAS-FIRED HIGH INTENSITY INFRARED HEATERS CATALOG 9-116.1 MARCH, 2003 TABLE OF CONTENTS Modine's MT Series is a gas-fired, high intensity ceramic infrared heater. Ideal for spot heating, the MT series

More information

Indirect Gas-Fired Make-Up Air

Indirect Gas-Fired Make-Up Air Indirect Gas-Fired Make-Up Air Model IG 800 to 7,000 cfm Up to 400,000 Btu/hr Multiple Furnace Control Options Optional Evaporative Cooling May 20041 Product Features Model IG Indirect Gas-Fired Make-Up

More information

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 95%+ AFUE Input 45,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially

More information

Direct Gas-Fired Make-Up Air

Direct Gas-Fired Make-Up Air Direct Gas-Fired Make-Up Air Model TSU Heavy Duty, High Airflow Applications Manufacturing and Industrial Facilities Up to 64,000 cfm August 2012 Products Model TSU Direct Gas-Fired Make-Up Air Unit The

More information

T15 Product Guide UNCOMPROMISED INDUSTRIAL-STRENGTH PERFORMANCE TO CLEAN BOTH OPEN AREAS AND TIGHT SPOTS PRODUCT HIGHLIGHTS KEY PRODUCT ENHANCEMENTS

T15 Product Guide UNCOMPROMISED INDUSTRIAL-STRENGTH PERFORMANCE TO CLEAN BOTH OPEN AREAS AND TIGHT SPOTS PRODUCT HIGHLIGHTS KEY PRODUCT ENHANCEMENTS UNCOMPROMISED INDUSTRIAL-STRENGTH PERFORMANCE TO CLEAN BOTH OPEN AREAS AND TIGHT SPOTS PRODUCT HIGHLIGHTS Built on the success of Tennant s small industrial battery riders; this next generation scrubber

More information

SERIES CONVECTION OVENS

SERIES CONVECTION OVENS SERIES CONVECTION OVENS SERIES BCO G BCO-G1 with optional casters Built tough & rugged like our more expensive models, the BCO models are our least expensive, full-size convection ovens. They feature independent

More information

F-Series Tower Drying

F-Series Tower Drying Tower Dryers F-Series Tower Drying F-Series Tower Drying We define grain drying. We define grain drying. FFI Features Gravity inlet does not require leveling auger, reducing the number of moving parts.

More information

RG7D 1-Stage Heat Series

RG7D 1-Stage Heat Series TECHNICAL SPECIFICATIONS RG7D 1-Stage Heat Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace

More information

1.03 DELIVERY, STORAGE, AND HANDLING Heater will be stored to secure against damage and handled per manufacturer s recommendations.

1.03 DELIVERY, STORAGE, AND HANDLING Heater will be stored to secure against damage and handled per manufacturer s recommendations. HVAC Guideline Specifications supraschwank Packaged Luminous Infrared Radiant Gas Heater Combined Intensity (produces both Low and High Intensity radiant output) Commercial/Industrial Applications Size

More information

ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector

ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector ALUMINUM REPAIR CERTIFICATION EQUIPMENT Eliminate hazardous aluminum dust with a Eurovac system BODY REPAIR EQUIPMENT OPTIONS Product Description When repairing an aluminum structured vehicle, it is essential

More information

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Construction Standards Page 233423-1 Copyright 2009 by The American Institute of Architects (AIA) Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Modified

More information

A. Product Data: Include rated capacities, furnished specialties and accessories.

A. Product Data: Include rated capacities, furnished specialties and accessories. BASE BID: SECTION 15542 FUEL-FIRED RADIANT HEATERS PART 1 - GENERAL 1.1 SUMMARY A. Furnish and install a Co-Ray-Vac Low Intensity Vented Infrared Radiant Vacuum Gas Heating System. System must be certified

More information

Home Stack Washer/Dryers

Home Stack Washer/Dryers Home Stack Washer/Dryers Refer to Page 3 for Model Numbers Parts SWD456C_806093 www.alliancelaundry.com Part No. 806093R1 December 2016 Table of Contents Title Page Parts Ordering Information... 2 Serial

More information

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett

More information

Cabinet Unit Heaters Steam / Hot Water

Cabinet Unit Heaters Steam / Hot Water 11-160.4 February, 2005 Cabinet Unit Heaters Steam / Hot Water Model C MODEL IDENTIFICATION Table of Contents I. Model Identification... 3 Page Il. IIl. III. IV. Design Benefits A. Features and Benefits...

More information

U n i t H e at e r s

U n i t H e at e r s Unit Heaters LF Models Enduring performance Allied commercial unit heaters are built to last, season after season Designed and built for durability and peak performance, Allied Commercial unit heaters

More information

Home Stack Washer/Dryers

Home Stack Washer/Dryers Home Stack Washer/Dryers Refer to Page 3 for Model Numbers Parts SWD456C_806093 www.alliancelaundry.com Part No. 806093R4 September 2018 Table of Contents Title Page Parts Ordering Information... 2 Serial

More information

1.1 This section applies to air handling units for HVAC Systems.

1.1 This section applies to air handling units for HVAC Systems. AIR HANDLING UNITS GENERAL INFORMATION 1.1 This section applies to air handling units for HVAC Systems. DESIGN REQUIREMENTS 2.1 Design Criteria a. The decision to use modular central station air handling

More information

BASIL 6000 TUNNEL CAGE WASHER

BASIL 6000 TUNNEL CAGE WASHER BASIL 6000 TUNNEL CAGE WASHER APPLICATION For thorough, efficient cleaning of cages, debris pans, bottles, feeder bowls, and miscellaneous items used in the care of laboratory animals. DESCRIPTION The

More information

AERATION AND GRAIN CONDITIONING FANS AND HEATERS PROVEN & DEPENDABLE

AERATION AND GRAIN CONDITIONING FANS AND HEATERS PROVEN & DEPENDABLE AERATION AND GRAIN CONDITIONING FANS AND HEATERS PROVEN & DEPENDABLE WWW.GRAINSYSTEMS.COM PROVEN & DEPENDABLE The demands of farming are never-ending. Maintaining consistent grain quality is essential

More information

RANGE. 2600/1950 Watts. 240/208 Volts BAKE ELEMENT /2100 Watts. 240/208 Volts. 90 degree BAKE ELEMENT Watts.

RANGE. 2600/1950 Watts. 240/208 Volts BAKE ELEMENT /2100 Watts. 240/208 Volts. 90 degree BAKE ELEMENT Watts. BAKE ELEMENT RANGE BAKE ELEMENT ADMIRAL AMANA CALORIC GLENWOOD HARDWICK IMPERIAL MAGIC CHEF MAYTAG WHIRLPOOL ROPER SUNRAY WELBILT 308180 2600/1950 Watts 240/208 Volts.250 male terminal push-in connection

More information

A. Codes and Standards that are Standard at the University:

A. Codes and Standards that are Standard at the University: PART 1: GENERAL 1.01 Purpose: 1.02 References: 1.03 Requirements: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The

More information

Homestyle Stack Washer/Dryers

Homestyle Stack Washer/Dryers Homestyle Stack Washer/Dryers Refer to Page 3 for Model Numbers Parts SWD456C_806105 www.alliancelaundry.com Part No. 806105R1 November 2015 Table of Contents Title Page Parts Ordering Information...

More information

SAFETY AND INSTALLATION MANUAL MODEL 8100

SAFETY AND INSTALLATION MANUAL MODEL 8100 SAFETY AND INSTALLATION MANUAL ENERGY RECOVERY VENTILATORS MODEL 8100 Provides year-round fresh air Recovers 77% of the apparent heating or cooling energy from the exhausted air See Warnings Page 3 Table

More information

Model UDAP. Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters DESCRIPTION STANDARD FEATURES OPTIONAL FEATURES - FACTORY INSTALLED

Model UDAP. Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters DESCRIPTION STANDARD FEATURES OPTIONAL FEATURES - FACTORY INSTALLED Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters Sizes 30-125 carry an additional approval for use in residential garage/workshops under CSA International Requirement 10.96 - U.S.

More information

Gas and Electric Convection Ovens

Gas and Electric Convection Ovens Gas and Electric Convection Ovens TURBO-FLOW TURBO-FLOW TURBO-FLOW TURBO-FLOW Door enhancements have increased the durability of the door mechanisms Dual-open doors one hand opens and closes both doors

More information

ENVIRONMENTAL EQUIPMENT Poly-Vent

ENVIRONMENTAL EQUIPMENT Poly-Vent Poly-Vent The Vanishing Window Poly-Vent is a modern alternative to inefficient and cumbersome roll-up vents. Heavy-duty, clear, UV-stabilized polyethylene opens from the top down without any moving parts

More information

Specifications 3. Bladder 5. Chimney 12. Air Supply 12. Anti-Rollout Device and Ash Auger Tube 14. Timer 15

Specifications 3. Bladder 5. Chimney 12. Air Supply 12. Anti-Rollout Device and Ash Auger Tube 14. Timer 15 TABLE OF CONTENTS Page No. Specifications 3 Bladder 5 Fire Door 7 Chimney 12 Air Supply 12 Anti-Rollout Device and Ash Auger Tube 14 Timer 15 Supply Line and Return Line Threaded Connectors 15 Low Water

More information

VENTLESS DOOR-TYPE DISHWASHER

VENTLESS DOOR-TYPE DISHWASHER Item # Quantity C.S.I. Section 11400 VENTLESS STANDARD FEATURES Internal condensing system minimizes water vapor Does not require a vent hood Energy recovery Sense-A-Temp 70 F rise electric booster heater.74

More information

JCseries EVAPORATIVE CONDENSER. engineering data

JCseries EVAPORATIVE CONDENSER. engineering data JCseries EVAPORATIVE CONDENSER engineering data Recold JC Series Evaporative Condenser Contents 2 Construction... 3 Schematic... 4 Engineering Data... 5 Selection Procedure... 6-9 Multi-Circuited Selection

More information

CABINET PARTS REFRIGERATOR

CABINET PARTS REFRIGERATOR CABINET PARTS REFRIGERATOR 1 94 Litho In U.S.A. 1 Part No. CABINET PARTS 2 2152011 Front Roller (2) 3 489393 Screw, 4 981122 Roller (Rear) (2) 5 488454 Screw 6 2155013 Clip, Grille 7 489242 Screw 9 836196

More information

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU) AIR HANDLERS Central Station (CS3) (Modular AL Frame AHU) Roof Mounted (RT) CONTENTS 1. CS3 Modular Aluminium Frame AHU : Unit Types 2. Casing Structure 3. Blowers and Drives 4. Coils 5. Options and Accessory

More information

1.03 RELATED SECTIONS: The following sections contain requirements that relate to this section.

1.03 RELATED SECTIONS: The following sections contain requirements that relate to this section. SECTION 15855 GAS FURNACE/DX COOLING UNIT PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of contract including General and Supplementary Conditions of Division 1 of Specification

More information

CL44eR DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE. Item # Quantity C.S.I.

CL44eR DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE. Item # Quantity C.S.I. Item # Quantity C.S.I. Section 11400 DISHWASHER STANDARD FEATURES Energy recovery 202 racks per hour Opti-RinSe system 30 KW electric booster heater Rapid return conveyor drive mechanism Insulated hinged

More information

ADG-531HS Hot Surface Ignition

ADG-531HS Hot Surface Ignition ADG-531HS Hot Surface Ignition Parts Manual 1998 American Dryer Corporation 88 Currant Road Fall River, MA 02720-4781 Telephone: (508) 678-9010 / Fax: (508) 678-9447 E-mail: techsupport@amdry.com 120997JEV/abe

More information

BUDERUS. Quality. Versatility. Efficiency. Superior Design. Comfortable. Efficient. Intelligent Heating. Conventional Gas Boilers

BUDERUS. Quality. Versatility. Efficiency. Superior Design. Comfortable. Efficient. Intelligent Heating. Conventional Gas Boilers BUDERUS Conventional Gas Boilers GC144 Series Residential Gas-Fired Boilers GA124 Series Gas-Fired Sealed Combustion Boilers G234X, G334X Series Gas-Fired Boilers Quality. Versatility. Efficiency. Superior

More information

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL POWER VENTED HD, HDB, PDP, BDP, PTP, BTP SEPARATED COMBUSTION HDS, HDC, PTS, BTS HIGH-EFFICIENCY SEPARATED COMBUSTION PTC, BTC 6-107.16 NOVEMBER,

More information

CONFINED SPACE VENTILATION

CONFINED SPACE VENTILATION CONFINED SPACE VENTILATION Version 1.0 1 DESIGNING THE FUTURE At Pearson Industries we understand that tough jobs require tougher tools, and for this industry, our fans have been designed to outperform

More information

SECTION DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS

SECTION DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS SECTION 237339 - DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary

More information

GAS DRYER MODELS: MGD8200FW0 (White) MGD8200FC0 (Chrome Shadow) 05/24/ Maytag Part No. W Rev. A

GAS DRYER MODELS: MGD8200FW0 (White) MGD8200FC0 (Chrome Shadow) 05/24/ Maytag Part No. W Rev. A GAS DRYER MODELS: MGD8200FW0 (White) MGD8200FC0 (Chrome Shadow) 05/24/2016 2016 Maytag Part W10884161 Rev. A TOP AND CONSOLE PARTS 05/24/2016 2 Part W10884161 Rev. A TOP AND CONSOLE PARTS Part Description

More information

CATALOG: HVAC - Gas Space Unit Heating

CATALOG: HVAC - Gas Space Unit Heating CATALOG: HVAC - **Wolff Bros. Supply, Inc. reserves the right to substitute like products. Product information is subject to Manufacturer rolling changes and/or typographical errors. Wolff Bros. Supply,

More information

Advance Release September 2009

Advance Release September 2009 Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*

More information

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 1029 L7 SLP98UHV SLP98UHV SERIES UNITS SLP98UHV series units are high efficiency upflow, horizontal right and left) gas furnaces equipped with variable capacity gas valve, variable

More information

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 can be

More information

CL64T INDUSTRIAL TOTE WASHER

CL64T INDUSTRIAL TOTE WASHER Item # Quantity C.S.I. Section 11400 STANDARD FEATURES Selectable Speed 4, 5, 6 feet/minute Opti-RinSe system Rapid return conveyor drive mechanism Insulated hinged double doors with door interlock switches

More information

HVAC. Air Blowers Fans Forced Air Heaters Heating Cables & Insulation Infrared & Radiant Heaters

HVAC. Air Blowers Fans Forced Air Heaters Heating Cables & Insulation Infrared & Radiant Heaters Air Blowers.................................352 Fans................................... 353-354 Forced Air Heaters........................... 354 Heating Cables & Insulation....................355 Infrared

More information

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL POWER VENTED HD, HDB, PDP, BDP, PTP SEPARATED COMBUSTION HDS, HDC, PTS, BTS HIGH-EFFICIENCY SEPARATED COMBUSTION PTC, BTC 6-107.14 JULY, 2013

More information

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh PRODUCT SPECIFICATIONS GAS UNIT HEATERS / DUCT FURNACES TU T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ Bulletin No. 20402 November 207 Supersedes November 206

More information

RECIRCULATING BATCH & AUTOMATIC GRAIN DRYERS

RECIRCULATING BATCH & AUTOMATIC GRAIN DRYERS DRYER CATALOG [785] 632-2151 [800] 423-9428 CLAY CENTER, KANSAS U.S.A. 67432 www.gtmfg.com info@gtmfg.com RECIRCULATING BATCH & AUTOMATIC GRAIN DRYERS [785] 632-2151 [800] 423-9428 CLAY CENTER, KANSAS

More information

29" GAS DRYER MODELS: MGD7000AW1 (White) MGD7000AG1 (Cosmetallic) 07/02/ Maytag Part No. W Rev. A

29 GAS DRYER MODELS: MGD7000AW1 (White) MGD7000AG1 (Cosmetallic) 07/02/ Maytag Part No. W Rev. A 29" GAS DRYER MODELS: MGD7000AW1 (White) MGD7000AG1 (Cosmetallic) 07/02/2013 2013 Maytag Part W10624907 Rev. A TOP AND CONSOLE PARTS 07/02/2013 2 Part W10624907 Rev. A TOP AND CONSOLE PARTS Part Description

More information

Distributed By: M&M Control Service, Inc Building Technologies

Distributed By: M&M Control Service, Inc Building Technologies Building Technologies Combustion Control Systems Count on Siemens. Siemens Building Technologies, the worldwide industry leader in combustion controls, delivers globally approved products specifically

More information

OPERATING & SERVICE PARTS MANUAL HDS-215 COMBINATION SHRINK SYSTEM

OPERATING & SERVICE PARTS MANUAL HDS-215 COMBINATION SHRINK SYSTEM OPERATING & SERVICE PARTS MANUAL HDS-215 COMBINATION SHRINK SYSTEM FOR HOT KNIFE AND IMPULSE MACHINES READ ALL INSTRUCTIONS CAREFULLY BEFORE OPERATING EQUIPMENT TABLE OF CONTENTS Electrical Requirements

More information

CLEARANCES TO COMBUSTIBLES

CLEARANCES TO COMBUSTIBLES 12288 Brawn Road 22, Wainfleet, Ontario, Canada L0S 1V0 Phone: 905-899-3473 Fax: 905-899-2262 www.easyradiantworks.com email: erw@vaxxine.com Engineering Submittal Data EZB series straight and U shape

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. Placement within a mechanical room is required for all major mechanical equipment. Only small units may be roof-mounted, and shall be made as inconspicuous

More information

VERTICAL FAN COIL UNITS

VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS Model: CT & TCE 2 - Pipe 350 cfm to 1200 cfm capacity 4-row water coil 120v or 24v controls Electric heating coil (TCE Model) Fresh air connection from remote

More information

SERIES. 10 year limited warranty on Burner Core 5 year limited warranty on All combustion and. 2 year limited warranty on All Burner Controls

SERIES. 10 year limited warranty on Burner Core 5 year limited warranty on All combustion and. 2 year limited warranty on All Burner Controls TM SERIES Available with 40,000 to 200,000 BTU/Hr. inputs and tube lengths from 10 feet to 70 feet. Aircraft Hangars Auto Dealerships Farm Buildings Fire Stations Body Shops Car Washes Sports Facilities

More information

DESIGNING A COMBUSTION AIR/GAS PRE MIX SYSTEM FOR RED RAY INFRARED PROCESS BURNERS

DESIGNING A COMBUSTION AIR/GAS PRE MIX SYSTEM FOR RED RAY INFRARED PROCESS BURNERS DESIGNING A COMBUSTION AIR/GAS PRE MIX SYSTEM FOR RED RAY INFRARED PROCESS BURNERS 1. Determine load requirements based on application () 2. Choose burner type based on process / application / requirements

More information

RGE 13 A T - 1 A

RGE 13 A T - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE

More information

SIOUX HYBRID WATER HEATER

SIOUX HYBRID WATER HEATER SIOUX Hybrid Water Heater for the Concrete Industry SIOUX HYBRID WATER HEATER Patent Pending Maximizing the Benefits of Coil and Direct-Fired Heating Technologies Higher Discharge Temperature True High-Efficiency

More information

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features: RL Packaged Rooftop Units, heat pumps and Outdoor air handling Units Features: Air-cooled condenser, water-cooled condenser, or patented AAON evaporative-cooled condenser, with capacities from 45-240 tons

More information

G124X - G234X - G334X Atmospheric Gas Boilers

G124X - G234X - G334X Atmospheric Gas Boilers G124X - G234X - G334X Atmospheric Gas Boilers Setting the Standard for Efficiency High Efficiency: Full line of Atmospheric Gas Boilers Flexible, Corrosion Resistant GL-180M Cast Iron Limited Lifetime

More information