1 Facade Fan Coil Unit Type FVD/FVDplus Floor Installation D Stuttgart, Grenzstraße (0711) , Fax +49 (0711) Internet: info@ltg -AG.de LTG Incorporated 105 Corporate Drive, Suite E Spartanburg S.C., USA +1 (864) , Fax +1 (864) Internet: info@ltg -INC.net LTG S.r.l. con socio unico Via G. Leopardi 10 I Melzo +39(02) ,Fax+39(02) Internet: ltg@ltgsrl.191.it FVD -E TP 01 (10/08)

2 Components for Room Air Technology Germany Central Office (Frankfurt) Sales area: PLZ 54, 55, 60, 63, 64, 66-69, 97 Sontraer Str. 27 D Frankfurt am Main (069) , Fax -10 E -mail: Bergmann@LTG -AG.de Central office (Herborn) Sales area: PLZ 30, 31, 34-38, 56, 57, 61, 65 Sperberweg 16 D Herborn Herr Hartmann (02772) , Fax -727 E -mail: Hartmann@LTG -AG.de Eastern office (Berlin) Sales area: PLZ 10-25, 29, 39 Eisenhutweg 51a D Berlin Herr Linke (030) , Fax -75 E -mail: Linke@LTG -AG.de Eastern office (Chemnitz) Sales area: PLZ 01-09, 98, 99 Johannes-Ebert-Straße 20 D Chemnitz Herr Schenfeld (0371) , Fax -02 E -mail: Schenfeld@LTG -AG.de Southern office Sales area: PLZ Grenzstraße 7 D Stuttgart Herr Gau (0711) , Fax -210 E -mail: Gau@LTG -AG.de Western office Sales area: PLZ 26-28, 32, 33, 40-53, Baststraße 30 D Oberhausen/Rheinl. Herr Perenz (0208) , Fax -56 E -mail: Perenz@LTG -AG.de Austria KTG Klimatechnische Gesellschaft mbh Schubertstraße 13, A Ladendorf (02575) 21089, Fax (02575) E -Mail: office@ktg -wien.com Great Britain MAP Motorised Air Products Ltd. Unit 5A, Sopwith Crescent Wickford Business Park Wickford GB -Essex SS11 8YU (01268) , Fax (01268) E -Mail: info@mapuk.com Netherlands Opticlima Systems Leeuwerikstraat 110, NL AG Ermelo (0341) , Fax (0341) E -Mail: info@opticlima.nl Poland HTK Went Sp.z.o.o. ul. Chopina 13/3, PL Krakow (012 ) , Fax (012) E -Mail: info@htk -went.pl Portugal ArGelo S. A. R. Luis Pastor de Macedo, Lote 28 B P Lisboa (21) , Fax (21) E -Mail: info@argelo.pt Slovenia Energo Plus Koprska 108 d, SLO Ljubljana (01) , Fax (01) E -Mail: info@energoplus.si Switzerland Laminair AG Kirchbergstrasse 105 Ch Burgdorf (034) , (034) E -Mail: info@laminair.ch Turkey Step Müh. Yapi Ltd. Yali Yolu Sokak, Turanli Apt. No: 24 D.1 TR Bostanci-Istanbul (0216) , Fax (0216) E -Mail: info@stepyapi.com.tr The Program for Room Air Technology Components Air diffusers for walls, floors and ceilings LTG System clean R linear diffusers Coandatrol R ceiling air diffusers Coandavent R displacement diffusers LTG chilling fans cool wave R induction units Klimavent R fan coil units Raumluft ceiling fan coil units Ventotel R facade fan coil units airflow control units labair R system Engineering services Technical services for investors, architects, engineers and plant builders during design, construction and operation of buildings. Reliable and precise data relating to the ventilation of air conditioning system are given already before realization of the project, determined by measurements, calculations, building simulations and experiments. Components for Process Air Technology Japan Toho Engineering Co. Ltd , Shimizu 3-Chome, Kita Ku Japan 462 Nagoya (052) , Fax (052) E -Mail: main@tohoeng.com The Program for Process Air Technology Components Axial -flow, centrifugal and tangential fans Collector system for: coarse and fine particle filtration, separating and compacting, compressing and humidifying. Engineering services Technical services for construction engineers and plant designers during development and operation of assembly groups, machines and plants. E Grenzstraße 7 D Stuttgart +49 (0711) Fax -720 Internet: info@ltg-ag.de Printed in Germany Ausgaben mit früherem Datum werden hiermit ungültig Technische Änderungen vorbehalten Former editions are invalid Subject to technical modifications.

3 Facade Fan Coil Unit Type FVD for floor installation with decentralized outside air supply via the facade, for heating and cooling Application The Facade Fan Coil Unit type FVD is a 4-pipe unit for the decentralized ventilation of occupied rooms (outer zones) via the facade using outside air, including cooling and heating. It is perfect for installation in false floors with an overall unit height of at least 203 mm when using floor panels (38 mm) with covering (8.5 mm) and a minimum height of 175 mm when placing the floor covering directly on the ventilation module. Since all components are below floor level, the FVD may be used in rooms with a full-surface facade glazing. Notes regarding the control: Since facade fan coil units are operated with both outside and room air some particularities will have to be considered when integrating the units in a control circuit (see installation instructions). Control strategies of standard fan coil unit controllers cannot be used without certain modifications. In any case, continuous control components will have to be used. Facade Room Air flow path FVD/direct induction Facade Fan Coil Unit, Type FVD R (picture without control valves, with water connection on the right, for demonstration purposes without ventilation module cover, inspection opening and foot traffic resistant grille) Functional Principle The centrifugal fan of the FVD sucks in outside air through a slot or opening in the facade element through the open shut-off damper of the FVD and a fine dust filter. The air is forced through a silencer and induction nozzles (to mix with room air) and passes through a 4-pipe heat exchanger with separate water circuits. The heated or cooled air is then expelled through the floor grille directly at the facade into the room (direct induction). This supply air flow mixes in summer with the warm room air, in winter with the falling cold air in front of the window (mixed air flow close to the facade). A displacement flow towards the core is created in the cooling mode by the mixed discharge flow. If the fan is isolated or in case of a power failure, the shutoff damper is closed safely through an actuator with spring return. The FVD will then serve as an underfloor convector e.g. for static heating of the room at night. Tolerances - For the data given in this brochure General Tolerances according to DIN 2768-vL apply. For the outlet grille the special tolerances given in the drawing apply. - Straightness and twist tolerances according to DIN EN Surface Finish - The surface finish was designed to meet requirements for the use in buildings - room air climate according to DIN 1946 Part 2. Other requirements on request. You will find the actual tender documentations at the end of this document. They are available in word format at your local dealership or at E Grenzstraße 7 D Stuttgart +49 (0711) Fax -720 FVD -E-TP (10/08) Former editions are invalid Subject to technical modifications. 3

4 Facade Fan Coil Unit Type FVDplus for floor installation with decentralized outside air supply via the facade, recirculating air mode, for heating and cooling Application The FVDplus has the same functions as the FVD but, additionally, includes a tangential fan used to recirculate room air and increase capacity in the fresh-air mode. Facade fan coil unit type FVDplus-4 -A R (picture without control valves, with water connection on the right, for demonstration purposes without ventilation module cover and without foot traffic resistant grille) Functional Principle The FVDplus allows for three different operating modes: 1. operation with fresh air intake only (the same as FVD) 2. operation as a recirculating air unit without outside air intake 3. operation with fresh air intake and recirculating air. 1. In the fresh air only mode the centrifugal fan of the FVDplus draws in outside air through a slot or opening in the facade element via the FVD s open shut-off damper and a fine filter. The air is passed through a silencer and is discharged via nozzles, to mix thoroughly, with room air before passing the 4 pipe heat exchanger with separate water circuits. 2. In the recirculating air only mode a noiseless fivespeed tangential fan draws room air through the ventilation grille. This air passes through the unit s heat exchanger and is reintroduced into the room over the fan s entire width. 3. In the combination mode the advantages of the above two modes are combined. The fresh air flow is supplemented by recirculated room air thereby increasing the heating cooling capacity of the unit. In any of the three modes the cooled or heated air is expelled vertically upwards through the floor grille close to the facade. This supply air flow mixes in summer with the hot room air, and in winter with the falling cold air in front of the window (creating a mixing zone close to the facade). In the cooling mode, the mixed air flow creates a displacement flow towards the room core. If the fan is isolated or in case of a power failure, the shutoff damper is closed safely through an actuator with spring return. The FVDplus will then serve as an underfloor convector e.g. for static heating of the room at night. Room Facade Air flow path FVDplus E Grenzstraße 7 D Stuttgart +49 (0711) Fax -720 FVD -E-TP (10/08) Former editions are invalid Subject to technical modifications. 4

5 Facade Fan Coil Unit Type FVD/FVDplus - Advantages Advantages Direct Induction The heat exchanger heats/cools room air and outside air which results in: increased heating and cooling output due to increased flow rate better protection against freezing better thermal comfort effective use of free cooling excellent room air flow with air diffusion close to the facade and mixed/displacement air flow. FVDplus: High performance due to mixed in room air and recirculating air fan Fast air conditioning due to increased output. Fast cooling/heating of completely cooled rooms. Ideal supplement to slow concrete core activation. Recirculating air flow rate independent of the outside air flow rate, to be selected by the user or cascade controlled. Cooling and heating also without outside air, air conditioning possible even with critical wind conditions. outside air T 32 _C room air T Raum 26 _C supply air outside air T 32 _C room air T Raum 26 _C supply air T WE 29 _C outside air through induction nozzles T KWVL 18 _C outside air through induction nozzles T WE 27,5 _C T KWVL 17 _C Direct induction principle Principle when mixing in room air Advantages Facade Fan Coil Unit Type FVD High output and frost protection - Designed for high capacity output - Easy frost protection possible through direct induction/mixing in room air Decentralized outside air supply - The outside air flow rate may be adjusted individually and according to requirement. - The occupants in the room may control the outside air flow through set values. - No plant room investment/space required for central supply air. Aesthetic design - Slim grille directly on the facade. - Continuous installation of the grille and the facade module. Low-noise operation - Low sound power level. - Good sound insulation to protect from outside noises such as traffic. Low energy consumption - Short air conveying distances, low pressure losses. - Use of a highly efficient EC motor in the centrifugal fan. - Low water-side pressure losses in the heat exchanger. Strict separation of the water circuits - 4-pipe heat exchanger with separate cooling and heating register. - Use of standard controllers possible. Flexible use thanks to modular design - Low installation height. - Dividing the system in two modules allows to meet any project requirement. - Length and width of the facade module may be changed to adapt the unit to other grid dimensions or the caloric output. - In case of a change of use, the units may easily be retrofitted. Quick and easy maintenance - Excellent accessibility of the filter, the shut-off damper, and the actuator by simply lifting the foot traffic resistant grille and one maintenance cover. - Easy cleaning of the facade module by lifting the grille and the heat exchanger. - Good accessibility of the fan and the silencer by lifting the floor panels and the ventilation module cover. The fan motor may be detached and removed from above. The silencer may be completely removed for cleaning the air paths. - For the FVDplus also excellent accessibility of the cross flow fan. Easy and clean installation - Separate installation of the air conditioner, the facade, and the false floor. The supporting feet may be adjusted from the outside without need to open the unit. Thus, contamination during installation is minimized. E Grenzstraße 7 D Stuttgart +49 (0711) Fax -720 FVD -E-TP (10/08) Former editions are invalid Subject to technical modifications. 5

6 Facade Fan Coil Unit Type FVD/FVDplus - Installation Example The Innovation Company Room Facade FVD Installation example: Continuous grille along the facade, facade fan coil unit FVD and aluminum roller grille Facade fan coil unit FVD after installation with cutout floor boards If the look of a continuous grille along the facade is required units are screw connected using matching black coated distance sheets. In case of end pieces and if the spacing is more than 400 mm supports will have to be used for stabilization. The LTG aluminum roller grille also allows for production of cutouts for columns and mitre edges. To meet any esthetic requirement we offer 3 grille types: 1. Stainless steel grille Facade fan coil unit FVD after installation with stainless steel grille 2. LTG aluminum roller grille 3. LTG aluminum grille E Grenzstraße 7 D Stuttgart +49 (0711) Fax -720 FVD -E-TP (10/08) Former editions are invalid Subject to technical modifications. 6

7 Facade Fan Coil Unit Type FVD - Dimensions Lateral view 18 A B 48 Front view Feet may be completely retracted Water connections to match the specific project 611 Dimensions A B FVD FVD Unit dimensions are set to match the specific project. Therefore, this dimensional sketch serves as an example only. Top view Isometric view E Grenzstraße 7 D Stuttgart +49 (0711) Fax -720 FVD -E-TP (10/08) Former editions are invalid Subject to technical modifications. 7

8 Facade Fan Coil Unit Type FVD - Technical Data Technical data type FVD (various flow rates) V [m#/h] L A18 [db(a)] L wa [db(a)] Q k 1 Q ksens 1 w ok / p w [kg/h]/[kpa] Q 2 h 1615 w oh / p w [kg/h]/[kpa] Q hst / / P el Technical data type FVD (various flow rates) V [m#/h] L A18 [db(a)] L wa [db(a)] Q k 1 Q ksens 1 w ok / p w [kg/h]/[kpa] Q 2 h 1670 w oh / p w [kg/h]/[kpa] Q hst / / The given data refer to the unit including fine filter F7, free-suction operation without external pressure loss. 1 Water supply temperature: 17 C, intake air temperature: 32 C, non-condensing operation (about 40% relative humidity), room air temperature: 26 C. 2 Water supply temperature: 75 C, intake air temperature: -12 C, room air temperature: 22 C. P el V - L A18 - L wa - Q k - flow rate ( 10%) sound pressure level with 18 m 2 Sabine room absorption sound power level ( 3dB) (without intake grille) cooling capacity Q ksens - w ok - p w - Q h - w oh - Q hst - P el - sensible cooling capacity standard water flow rate at cooling capacity* water-side pressure loss heating capacity standard water flow rate at heating capacity* static heating capacity electric power consumption ( 20%) * correction for other flow rates see page 9/10 E Grenzstraße 7 D Stuttgart +49 (0711) Fax -720 FVD -E-TP (10/08) Former editions are invalid Subject to technical modifications. 8

9 Facade Fan Coil Unit Type FVD - Selection Due to the many parameters decisive for a decentralized unit s output we will state one example only. Further selections are possible using a special LTG program available through Example for: Type FVD Grille width 300 Outside air flow rate 120 m 3 /h Room air temperature 26 _C Water supply temperature 17 _C Nominal water volume 200 kg/h Cooling capacity with different flow rates Cooling capacity Qk Overall cooling capacity Room-effective output 50_C Intake air temperature 0 40_C Intake air temperature 32_C Intake air temperature Flow rate in % of the nominal flow rate Water-side pressure loss of the cooling register with different flow rates Water-side pressure loss pw [kpa] Flow rate w [kg/h] E Grenzstraße 7 D Stuttgart +49 (0711) Fax -720 FVD -E-TP (10/08) Former editions are invalid Subject to technical modifications. 9

10 Facade Fan Coil Unit Type FVD - Selection Due to the many parameters decisive for a decentralized unit s output we will state one example only. Further selections are possible using a special LTG program available through. Example for: Type FVD Grille width 300 Outside air flow rate 120 m 3 /h Room air temperature 22 _C Water supply temperature 75 _C Nominal water volume 100 kg/h Heating capacity with different flow rates 4500 Heating capacity Qh Overall heating capacity Room-effective output _C Intake air temperature _C Intake air temperature - 20_C Intake air temperature Flow rate in % of the nominal flow rate 200 Water-side pressure loss of the heating register with different flow rates Water -side pressure loss pw [kpa] Flow rate w [kg/h] E Grenzstraße 7 D Stuttgart +49 (0711) Fax -720 FVD -E-TP (10/08) Former editions are invalid Subject to technical modifications. 10

11 Facade Fan Coil Unit Type FVD - Electrical Connection Electrical Connection The unit is provided with connecting cables equipped with connector sleeves. Electrical connection is made, on site, via a terminal box mounted to the unit (protection IP66). Available are 3 outside air flow rates which may be triggered directly via a control line. This control line has an outside air flow-dependent voltage of up to mains potential. Activation in groups of up to 3 units is possible (using the same phase). An error message may be applied to the terminal box. The message will be displayed in case one of the following conditions occurs: - the fan does not run, irrespective of load applied - antifreeze is active (heat exchanger temperature < 10 _C) - set flow rate is not achieved within 120 seconds. Connection of a diffused air temperature sensor is optional. Facade fan coil unit terminal box On -site wiring temp - 1 PWM Tacho X7-2 Party Day Night Antifreeze 5 Belimo X6 Temp U5 Y μ PE N N L X5 F2 F1 220/24 V, 6,0 VA F1 = 32 ma, tr F2 = 1,0 A, tr L PE N Sign Error Mains Speeds Error Power supply conn. 230 V Line:3x0,75mm 2 Outside air flow rates I - III Line:4x0,75mm 2 Electrical isolation required Connection via floating contacts Fan error message Line:2x0,5mm 2 E Grenzstraße 7 D Stuttgart +49 (0711) Fax -720 FVD -E-TP (10/08) Former editions are invalid Subject to technical modifications. 11

12 Facade Fan Coil Unit Type FVDplus - Dimensions 305 Lateral view Front view 155 Feet may be completely retracted Water connections to match the specific project Top view Unit dimensions are set to match the specific project. Therefore, this dimensional sketch serves as an example only. Isometric view E Grenzstraße 7 D Stuttgart +49 (0711) Fax -720 FVD -E-TP (10/08) Former editions are invalid Subject to technical modifications. 12

13 Facade Fan Coil Unit Type FVDplus - Technical Data Model size pipe system - Cooling and heating with recirculating air only n [-] V [m#/h] L wa [db(a)] Q k 1/ t [W/K] Q k 1 w ok / p w [kg/h]/[kpa] Q h 1/ t [W/K] Q h 2 w oh / p w [kg/h]/[kpa] I II III / / IV V Model size pipe system - Cooling and heating with outside air only V [m#/h] L A18 [db(a)] L wa [db(a)] Q k 1 w ok / p w [kg/h]/[kpa] Q 2 h 820 w oh / p w [kg/h]/[kpa] / / P el 16 P el 5 Model size pipe system - Cooling and heating Example of a combination of 120 m 3 /h outside air and recirculating air n [-] L A18 [db(a)] L wa [db(a)] Q k 1 w ok / p w [kg/h]/[kpa] Q 2 h 1740 I II III / IV V w oh / p w [kg/h]/[kpa] 100 / 3.4 Acoustic data including outside air filter F7 and free-suction operation without external pressure loss. Data apply to the unit with intake and outlet grille, including simulated facade. Data based on VDMA Standard Sheet (draft). 1 Water supply temperature: 17 C, room air temperature: 26 C, intake air temperature: 32 C. 2 Water supply temperature: 50 C, room air temperature: 22 C, intake air temperature: -12 C. n - V - L A18 - L wa - Q k - t - speed flow rate ( 10%) pressure level with 18 m 2 Sabine room absorption sound power level ( 3dB) (without intake grille) cooling capacity temperature difference between induction air temperature before entering the heat exchanger and water supply w ok - p w - Q h - w oh - P el - standard water flow rate at cooling capacity* water-side pressure loss heating capacity standard water flow rate at heating capacity* electric power consumption ( 20%) * correction for other flow rates see page 14/15 E Grenzstraße 7 D Stuttgart +49 (0711) Fax -720 FVD -E-TP (10/08) Former editions are invalid Subject to technical modifications. 13

14 Facade Fan Coil Unit Type FVDplus - Selection Due to the many parameters decisive for a decentralized unit s output we will state one example only. Further selections are possible on request. Example for type FVDplus Grille width 300 Outside air flow rate 120 m 3 /h Room air temperature 26 _C Water supply temperature 17 _C Nominal water volume 200 kg/h Speed level II Cooling capacity with different flow rates Cooling capacity Qk Overall cooling capacity Room-effective output 50_C Intake air temp. 0 40_C Intake air temp. 32_C Intake air temp Water volume in % of the nominal water volume Water-side pressure loss of the cooling register with different flow rates 25 Water-side pressure loss pw [kpa] Water volume w [kg/h] E Grenzstraße 7 D Stuttgart +49 (0711) Fax -720 FVD -E-TP (10/08) Former editions are invalid Subject to technical modifications. 14

15 Facade Fan Coil Unit Type FVDplus - Selection Due to the many parameters decisive for a decentralized unit s output we will state one example only. Further selections are possible on request. Example for type FVDplus Grille width 300 Outside air flow rate 120 m 3 /h Room air temperature 22 _C Water supply temperature 75 _C Nominal water volume 100 kg/h Speed level II Heating capacity with different flow rates Heating capacity Qh Overall heating capacity Room-effective output _C Intake air temperature _C Intake air temperature - 20_C Intake air temperature Flow rate in % of the nominal flow rate 150 Water-side pressure loss of the heating register with different flow rates 15 Water-side pressure loss pw [kpa] Flow rate w [kg/h] E Grenzstraße 7 D Stuttgart +49 (0711) Fax -720 FVD -E-TP (10/08) Former editions are invalid Subject to technical modifications. 15

16 Facade Fan Coil Unit Type FVD/ FVDplus - Control Specifications The Innovation Company When integrating the facade fan coil unit type FVD/ FVDplus into a closed-loop control circuit the following particuliarities will have to be considered: In the decentralized facade fan coil unit type FVD/ FVDplus, both outside air and room air are routed through the heat exchanger. As outside air temperature variations can be significantly higher than intake temperatures in standard recirculating air units, standard fan coil unit control strategies cannot be used without making certain modifications. Room Temperature Control Room temperature control must be cascade controlled in a way to ensure that the required room temperature in the occupied zone is achieved. In any case, this will require the use of continuous control valve actuators or alternatively, three-position actuators. Wind Pressure Control / Supply Air Flow Rate Maintaining the required outside air flow rate as a function of applied wind pressures at the suction inlet will be ensured by a controller integrated in the fan coil unit s power electronics. No external access to this controller is provided. Three connectable flow rates represent the customer specified set flow rates (e.g. 90 m 3 /h m 3 /h m 3 /h). If no flow rate is chosen, the unit will shut the outside air damper and stop the fan. The required outside air flow rate may be selected/switched by an external controller chosing among three different set flow rates. With no voltage supplied, the outside air damper will be shut in the spring return mode. Frost Protection Since the heat exchanger in decentralized A/C units can handle outside air there is risk that the heat exchanger might freeze in the case of LPHW/LTHW failure or fan motor failure. Such failure may be detected before causing any damage to the heat exchanger by monitoring the diffused air temperature. An optional digital anti-freeze sensor monitoring the diffused air temperature will shut off the fan if the temperature drops below the limit of 10 _C and close the outside air damper. This function is not invoked, in both heating & cooling mode, if the unit is working correctly. The digital anti-freeze sensor will not protect from simultaneous controller failure. Therefore, maximum security is achieved if an additional automatic frost protection controller with capillary tube sensor is used in terms of a redundant system. If the temperature at the sensor rises above 15 _C, the unit will be put back into operation. An external controller may have additional access via an optional additional diffused air temperature sensor, so that further error messages may be displayed and the outside air dampers be closed (fan - set flow rate 0). Diffused Air Temperature Limiting In order to optimize comfort in the occupied zone the diffused air temperature will have to be monitored and its lower limit be restricted through suitable valve settings. This limit should not be more than 8 K below room temperature. However, this will also limit the available cooling capacity. Starting In case of low outside air temperatures, pre-heated water must flow though the heat exchanger when starting the unit and opening the outside air damper. Nocturnal Cooling Using a suitable control strategy, the facade fan coil unit might also be used to cool the building structure if nocturnal temperatures are low (but not falling below 10 _C). Minimum Air Volume To minimize building energy expense, the outside air volume should be reduced to the minimum flow necessary for occupancy. E Grenzstraße 7 D Stuttgart +49 (0711) Fax -720 FVD -E-TP (10/08) Former editions are invalid Subject to technical modifications. 16

17 Facade Fan Coil Unit Type FVD/FVDplus - System Components The Innovation Company Description Usually one unit every other grid is sufficient to satisfy the requirements of a 2 module room with 2 people or a 3 module room with 3 people Many architects, however, require the grille to be installed in a a continuous format. Module FVD-W has been specifically designed for this purpose. This module not only takes the grille but may be converted in various steps whenever required. Advantages Flexibility and comfort - Typical reasons for changing modules: An existing/new tenant might require more cooling capacity, removing office partition walls to convert several small offices into one large office room or a complete office refit. The additional modules may serve to either provide an increased cooling capacity or to retrofit meeting rooms with more outside air without the need to replace the empty tray or the outside air unit. The required supplement modules are simply added and installed. Easy control - Use of the operating unit can be continued even when modules have been supplemented. The second module can be switched synchronously to the first. No new wiring or additional control functions are required. Base Level A unit in every second module with 120 m 3 /h (fresh air for 3 persons) and empty tray. Solution for standard offices. Valves for the FVD-A may be integrated in the FVD-W and are, thus, more easily accessible than in the false floor. FVD-A/FVDplus-A FVD-W Facade Heat exchanger FVD -A standard unit - tra y - grille - 4 -pipe heat exchanger - fan, sound absorber - outside air connection, damper, filter Empty tray module - for building module without FVD -A unit - tra y - grille suitable for retrofitting with module FVD -L. Conversion stage 1 Retrofitting static heating Solution e.g. for corner rooms in buildings. FVD -A/FVDplus -A FVD-H Heat exchanger Heat exchanger Module FVD -H - activation of the adjacent module - extension of an empty tray with a heat exchanger to double the static heating capacity. Facade for dimensions and technical data see next pages Conversion stage 2 Increase the cooling capacity. A unit in every second module with 120 m 3 /h (fresh air for 3 persons). Solution e.g. for corner rooms in buildings. FVD-AL/FVDplus-AL FVD-L Facade Heat exchanger Heat exchanger Module FVD -L - enlargement of a tray module FVD -W + a standard unit FVD -A to obtain a unit with increased cooling capacity - module FVD -L will be supplied with air via the FVD -A unit - heat exchanger is inserted in the tray Conversion stage 3 Double fresh air + cooling capacity. per module if there are two facade openings (fresh air for 6 persons). Solution e.g. for meeting rooms. FVD -A/FVDplus -A Heat exchanger FVD-A/FVDplusA Heat exchanger Facade Conversion of the empty tray to obtain a second FVD-A standard unit - 4 -pipe heat exchanger - fan, sound absorber - outside air connection, damper, filter E Grenzstraße 7 D Stuttgart +49 (0711) Fax -720 FVD -E-TP (10/08) Former editions are invalid Subject to technical modifications. 17

18 Heating Convector Type FVD-H Application The heating convector type FVD-H is a 2-pipe underfloor convector for static heating. The heating convector has been designed for installation in false floors. Required minimum false floor height is 180 mm. Functional Principle Cooled room air enters the grille positioned on top of the unit. Natural convection ensures draught -free flow of heated air into the room. The heat exchanger has been optimized specifically for low water volumes and high caloric outputs. Control Control is realized via standard radiator valves. The heat exchanger is provided with a smooth tube connection for direct connection of flexible hoses via quick release coupling. Dimensions Technical data Type FVD-H 1000 (different water inlet temperatures) t VL [_C] Q h w oh / p w [kg/h]/[kpa] 100 / 4 At 20 _C room temperature (intake temperature) Water flow rate 100 kg/h Front view ,5 Lateral wiew ,5 (158) Feet may be completely retracted 36 Top view 305 Water connections to match the specific project Unit dimensions are set to match the specific project. Therefore, this dimensional sketch serves as an example only. Isometric view E Grenzstraße 7 D Stuttgart +49 (0711) Fax -720 FVD -E-TP (10/08) Former editions are invalid Subject to technical modifications. 18

19 Heating Convector Type FVD-H Capacity with different flow rates Capacity in % of the nominal capacity Q Flow rate w [kg/h] Water-side pressure loss with different flow rates 50 Water -side pressure loss pw [kpa] Flow rate w [kg/h] E Grenzstraße 7 D Stuttgart +49 (0711) Fax -720 FVD -E-TP (10/08) Former editions are invalid Subject to technical modifications. 19

20 Facade Fan Coil Unit Type FVD/FVDplus Installation The compact design with a unit depth of 511 mm and a grille width of 200 mm or 611 mm with a grille with of 300 mm (FVDplus grill width 300 mm only), respectively, allows for installation of the unit between floor supports. Precise alignment of the unit is achieved through height adjustable feet. The valve chamber for connection of the control valves is located on the side opposite the intake opening side. Feed-throughs for the water connection tubes are also on the side opposite the intake opening, in the facade module s back panel. The upper edge of the unit and thus of the traffic resistant ventilation grille is to be installed flush to the prefabricated floor. In the ventilation module area, floor panels may be placed on the ventilation module cover using insulating washers. Fassade Special versions / Accessories - Control valves with either continuous or 3 point actuators. - Flexible insulated hoses with quick and safe release plug-in connections to the heat exchanger and integrated air-release valves. - Solid ventilation grille, foot traffic resistant without the use of any additional cross members, with fins parallel to the facade. According to requirement, either steel with an abrasionproof coating or stainless steel, inserted in the facade module from above. The grille is available in a variable length, independent of the unit, e.g. matching the grid dimension. The use of grilles of other brands requires s express approval in order to ensure a troubleless operation of the entire system. - Suitable filter cartridges, fine filter F7. - Antifreeze controller to monitor outside temperatures. It may be set to a selectable air temperature, e.g. 5_Cin winter, at which the fan is cut off and the outside air damper is closed in case of a hot water supply failure to avoid freezing of the heat exchanger. - Actuators with spring return to safely close the outside air shut-off damper in case of a power failure Facade Fan Coil Unit Type FVD - Installation on the facade with floor panels and floor covering. Facade Fan Coil Unit Type FVD - Replacement of filter E Grenzstraße 7 D Stuttgart +49 (0711) Fax -720 FVD -E-TP (10/08) Former editions are invalid Subject to technical modifications. 20

21 Facade Fan Coil Unit Type FVD/FVDplus - Nomenclature FVD A R / D / 1R / E / S outside air outside air + recirc. air FVD FVDplus 2-pipe unit 2 4-pipe unit 4 standard unit standard unit for use of L module tray module retrofitting static heating retrofitting output increase A AL W H L construction length 1200 grille width 200 (FVDplus 300 only) 300 water connection side right R left L straightway 3-point valve D 3-way 3-point valve 3 without edge profile for distance sheet OR 1 edge profile 1R 2 edge profiles 2R grille stainless steel aluminium roller grille 20 mm steel, coated aluminum, anodised E AR SB AE housing, coated black housing, coated in special color S SO E Grenzstraße 7 D Stuttgart +49 (0711) Fax -720 FVD -E-TP (10/08) Former editions are invalid Subject to technical modifications. 21

22 Specification and Schedule of Prices Facade Fan Coil Unit (according to design patent DE ) Base Unit FVD-A Edition / page 1 Qty. Description Unit price Total price General Description Facade fan coil unit for installation in false floors for a decentralized ventilation of occupied rooms via the facade, as well as for heating and cooling outside air with added room air for: - increased caloric output. - high thermal comfort due to a temperature increase of the diffused air. - lower risk of freezing and condensation. Data and Classification according to VDMA Standard Sheet (draft) Nominal heating capacity of the unit Nominal room heating capacity Grille width [mm] Nominal outside air flow rate (+/- 8 %) [m 3 /h] Outside air temperature [ C] (temperature of the outside air sucked in by the unit) Room air temperature [ C] Hot water supply temperature [ C] Hot water return temperature [ C] Nominal heating capacity of the unit (- 5 %) Nominal room heating capacity Nominal water flow rate [kg/h] Nominal pressure loss [kpa] Recommended use with a water supply temperature of 50 C (e.g. for use of a heat pump in central return air) Hot water supply temperature [ C] Hot water return temperature [ C] Nominal heating capacity of the unit (- 5 %) Nominal room heating capacity Nominal water flow rate [kg/h] Nominal pressure loss [kpa] 6 2 Nominal cooling capacity of the unit Nominal room cooling capacity Nominal outside air flow rate (+/- 8 %) [m 3 /h] Outside air temperature [ C] (temperature of the outside air sucked in by the unit) Room air temperature [ C] Cold water supply temperature [ C] Cold water return temperature [ C] Nominal cooling capacity of the unit (- 5 %) Nominal room cooling capacity Nominal water flow rate [kg/h] Nominal pressure loss [kpa] Free intake, free diffusion Technical data apply for free suction on the intake opening and grille on the outlet. -2-, Grenzstraße 7, D Stuttgart, Tel.: +49 / 711 / , Fax.: +49 / 711 / Ausgaben mit früherem Datum werden hiermit ungültig. Technische Änderungen vorbehalten. Former editions are invalid. Subject to technical modifications.

23 Specification and Schedule of Prices Facade Fan Coil Unit (according to design patent DE ) Base Unit FVD-A Edition / page 2 Qty. Description Unit price Total price Nominal outside air flow Nominal outside air flow (+/- 8 %) [m 3 /h] Sound power level Sound power level (+/-3 db) including F7 filter (free suction and diffusion): 120 m 3 /h (nominal outside air flow) [db(a)] m 3 /h [db(a)] m 3 /h [db(a)] 32 Sound reduction index Weighted sound reduction index of the unit with open outside air damper related to the suction area A. A [m 2 ] 0,018 Rw, [C tr ] [db] 28, [-7] Wind impact Meets the highest requirements of Unit Category III for external static pressure differences +/-200 Pa. Compensation of the filter pressure loss through integrated flow rate control. Maximum external pressure to be compensated with nominal outside air flow rate: Nominal outside air flow rate (+/- 20 %) [m 3 /h] 120 Positive wind pressure [Pa] Negative wind pressure [Pa] -300 Power consumption Low noise centrifugal fan with energy saving, highly efficient, infinitely variable EC motor for outside air flow rates of m 3 /h. 120 m 3 /h (nominal outside air flow) m 3 /h m 3 /h 9 El. power consumption max 100 Required back-up fuse [A] 10 Fan connection [V] , Grenzstraße 7, D Stuttgart, Tel.: +49 / 711 / , Fax.: +49 / 711 / Ausgaben mit früherem Datum werden hiermit ungültig. Technische Änderungen vorbehalten. Former editions are invalid. Subject to technical modifications.

24 Specification and Schedule of Prices Facade Fan Coil Unit (according to design patent DE ) Base Unit FVD-A Edition / page 3 Qty. Description Unit price Total price Air filter for outside air and exhaust air The supply air unit is equipped with an outside air filter F7 (including a warning sign for the direction of air, filter type, inspection interval and date of last filter change) - without exhaust air filter. Filters made entirely from synthetic composite materials Supply air diffusers Facade fan coil unit with mixed-in room air for high thermal comfort thanks to an increased temperature of the diffused air, and supply air diffuser with mixed displacement air flow. DIN 1946 Part 2 requirements are met for the nominal outside air flow. Outside air damper / Exit air damper Internal air tightness of the unit In case of a power failure the outside air damper is shut automatically by an actuator with spring return. Leakage air flow Meets: Referencerelated to: permeabilitx for 100 Pa: damper dimension Class 4 Q100 = 0,13 m 3 /hm Leakage air flow of the outside air damper when shut: wind pressure Pa [m 3 /h] < 1 wind pressure Pa [m 3 /h] < 1 Internal leakage air flow [%] < 5 Condensate tray The unit is provided with a condensate tray without drainage and slope for temporary condensate formation. Continuous condensate formation is not provided for and covered. Sanitation The upper material of the lining e.g. on the sound absorber and the 13 mm thick heat insulation is made of abrasion resistant glass fleece. Cut edges are protected against fibre release. The sound absorber sliding block inside the ventilation module may easily be removed to clean air conveying components. The ventilation module cover is easy to remove for inspection using a siphon. Filter, actuator, outside air damper, heat exchanger, and condensate tray are easily accessible inside the facade module underneath the supply air grille. -4-, Grenzstraße 7, D Stuttgart, Tel.: +49 / 711 / , Fax.: +49 / 711 / Ausgaben mit früherem Datum werden hiermit ungültig. Technische Änderungen vorbehalten. Former editions are invalid. Subject to technical modifications.

25 Specification and Schedule of Prices Facade Fan Coil Unit (according to design patent DE ) Base Unit FVD-A Edition / page 4 Qty. Description Unit price Total price Material Unit with adjustable feet. The self supporting housing is made of galvanized steel, visible parts powder coated in black (other colors on request), a 4 pipe heat exchanger with copper tubes and aluminum fins for cooling and heating. Heat exchanger connection with DN = 12 mm smooth copper tube for connection of flexible hoses with use of a quick release coupling. Water connection side always opposite the outside air intake opening side. Facade module with integrated condensate tray with inserted traffic resistant 300 mm / 200 mm wide and LLLL mm long ventilation grille of stainless steel or, alternatively, aluminum. The ventilation module is suitable for taking floor panels. It meets Load Class 2 requirements (standard office areas nominal load 3000 N) according to DIN EN False Floors or Load Class 3 according to the application guideline for false floors. Dimensions and Dimensional Limits FVD-A-LLLL-BBB-X A = module; L = length or size in mm B = grille width facade module in mm X = L for left, R for right version. Suitable for installation in false floors. Modular construction of the unit, splitted in facade module and ventilation module to meet any facade geometry requirements. Unit feet height adjustable from the outside with a possibility for complete retraction without need to open the unit. Unit height [mm] 155 When placing a floor panel (38-40 mm thick) with floor covering (8-10 mm thick) on top: Min. overall height [mm] 203 (to upper edge ventilation grille) When placing a floor covering (8-10 mm thick) directly onto the ventilation module: Min. overall height [mm] 175 (to upper edge ventilation grille) -5-, Grenzstraße 7, D Stuttgart, Tel.: +49 / 711 / , Fax.: +49 / 711 / Ausgaben mit früherem Datum werden hiermit ungültig. Technische Änderungen vorbehalten. Former editions are invalid. Subject to technical modifications.

26 Specification and Schedule of Prices Facade Fan Coil Unit (according to design patent DE ) Base Unit FVD-A Edition / page 5 Qty. Description Unit price Total price Operating Overpressures Admissible water side operating pressure 12 bar. Heat exchanger approved for a maximum water pressure of 15 bar. Corrosion Protection The unit housing is made of galvanized steel, visible parts powder coated. Ventilation grille of stainless steel or, alternatively, aluminum. Manufacturer: Series: Facade Fan Coil Unit Type: FVD-A Accessories/special version (optional, at extra charge): o o o o o o o o Stainless steel grille Aluminum - Roller grille Prepared for installation in line Differently formed side panel to take a connecting sheet and give the grille a continuous look Special version FVD-AL prepared for adding an FVD-L module Control With optional diffused air temperature sensor for thermal comfort and easy control of the diffused air temperature, e.g. PT 1000 with 1 m cord and plug (e.g. white) for connection to the room controller. Antifreeze The unit may be equipped internally (optional) with a frost protection and a digital diffused air temperature sensor. By mixing in room air the sensor may detect a frost hazard with diffused air temperatures as high as 10 C. The unit shuts off if the diffused air temperature drops below 10 C and restarts if it rises above 15 C. Alternatively, an independent automatic frost controller may be integrated. Straight-way valve with continuous actuator (0 10 V) cooling Straight-way valve with continuous actuator (0 10 V) heating, Grenzstraße 7, D Stuttgart, Tel.: +49 / 711 / , Fax.: +49 / 711 / Ausgaben mit früherem Datum werden hiermit ungültig. Technische Änderungen vorbehalten. Former editions are invalid. Subject to technical modifications.

27 Specification and Schedule of Prices Facade Fan Coil Unit (according to design patent DE ) Base Unit FVDplus-A Edition / page 1 Qty. Description General Description Facade fan coil unit with integrated recirculating air fan for installation in false floors for a decentralized ventilation of occupied rooms via the facade, and for heating and cooling outside air with added room air. room air is added in the outside air only mode through induction, with the recirculating air fan operating the added room air volume is significantly increased. The adding of room air results in: - increased caloric output. - high thermal comfort due to a temperat. increase of the diffused air. - lower risk of freezing and condensation. Data and Classification according to VDMA Standard Sheet (draft) Nominal heating capacity of the unit 300 Nominal room heating capacity Grille width [mm] 300 Nominal recirculating air level [-] II Nominal outside air flow (+/- 8 %) [m 3 /h] 120 Outside air temperature [ C] -12 (temperature of the outside air sucked in by the unit) Room air temperature [ C] 22 Hot water supply temperature [ C] 75 Hot water return temperature [ C] 51,5 Nominal heating capacity of the unit (- 5 %) 2744 Nominal room heating capacity 1800 Nominal water flow rate [kg/h] 100 Nominal pressure loss [kpa] 3,4 Nominal cooling capacity of the unit 300 Nominal room cooling capacity Nominal outside air flow rate (+/- 8 %) [m 3 /h] 120 Outside air temperature [ C] 32 (temperature of the outside air sucked in by the unit) Room air temperature [ C] 26 Cold water supply temperature [ C] 17 Cold water return temperature [ C] 20,3 Nominal cooling capacity of the unit (- 5 %) 770 Nominal room cooling capacity 530 Nominal water mass flow rate [kg/h] 200 Nominal pressure loss [kpa] 6,2 Free intake, free diffusion Technical data apply for free suction on the intake opening and grille on the outlet. -2- Unit price Total price, Grenzstraße 7, D Stuttgart, Tel.: +49 / 711 / , Fax.: +49 / 711 / Ausgaben mit früherem Datum werden hiermit ungültig. Technische Änderungen vorbehalten. Former editions are invalid. Subject to technical modifications.

28 Specification and Schedule of Prices Facade Fan Coil Unit (according to design patent DE ) Base Unit FVDplus-A Edition / page 2 Qty. Description Nominal outside air flow 300 Nominal outside air flow (+/- 8 %) [m 3 /h] 120 Sound power level Outside air fan Sound power level (+/- 3dB) including F7 filter (free suction and diffusion): 120 m 3 /h (nominal outside air flow) [db(a)] m 3 /h [db(a)] m 3 /h [db(a)] 32 Recirculating air fan Sound power level (+/- 3 db): Speed level I [db(a)] 29 Speed level II [db(a)] 33 Speed level III [db(a)] 40 Speed level IV [db(a)] 45 Speed level V [db(a)] 51 Sound reduction index Weighted sound reduction index of the unit with open outside air damper related to the suction area A. A [m 2 ] 0,018 Rw, [C tr ] [db] 28, [-7] Wind impact Meets the highest requirements of Unit Category III for external static pressure differences of +/- 200 Pa. Compensation of the filter pressure loss through integrated flow rate control. Maximum external pressure to be compensated with nominal outside air flow rate: Nominal outside air flow rate (+/- 20 %) [m 3 /h] 120 Positive wind pressure [Pa] Negative wind pressure [Pa] -300 Unit price Total price -3-, Grenzstraße 7, D Stuttgart, Tel.: +49 / 711 / , Fax.: +49 / 711 / Ausgaben mit früherem Datum werden hiermit ungültig. Technische Änderungen vorbehalten. Former editions are invalid. Subject to technical modifications.

29 Specification and Schedule of Prices Facade Fan Coil Unit (according to design patent DE ) Base Unit FVDplus-A Edition / page 3 Qty. Power consumption Description Outside air fan Low noise centrifugal fan with energy saving, highly efficient, infinitely variable EC motor for outside air flow rates of m 3 /h. 120 m 3 /h (nominal outside air flow) 9 90 m 3 /h 7 60 m 3 /h 5 El. power consumption max. 100 Required back up fuse [A] 10 Fan connection [V] 230 Recirculating air fan Low noise cross flow fan with energy saving, highly efficient 5-speed motor. Speed I 16 Speed II 17,5 Speed III 19,5 Speed IV 22 Speed V 27 El. power consumption max. 40 Required back up fuse [A] 0,2 Fan connection [V] 230 Air filter for outside air and exhaust air The supply air unit is equipped with an outside air filter F7 (including a warning sign for the direction of air, filter type, inspection interval and date of last filter change) - without exhaust air filter. Filters made entirely from synthetic composite materials Supply air diffusers Facade fan coil unit with mixed-in room air for high thermal comfort thanks to an increased temperature of the diffused air, and supply air diffuser with mixed displacement air flow. DIN 1946 Part 2 requirements are met for the nominal outside air flow. Unit price Total price -4-, Grenzstraße 7, D Stuttgart, Tel.: +49 / 711 / , Fax.: +49 / 711 / Ausgaben mit früherem Datum werden hiermit ungültig. Technische Änderungen vorbehalten. Former editions are invalid. Subject to technical modifications.

Facade Fan Coil Unit. Type A/C System FVM. For Facade Installation

Facade Fan Coil Unit. Type A/C System FVM. For Facade Installation Facade Fan Coil Unit Type A/C System FVM For Facade Installation D - 70435 Stuttgart, Grenzstraße 7 +49 (0711) 82 01-0, Fax +49 (0711) 82 01-720 Internet: http://www.ltg-ag.de E-Mail: info@ltg -AG.de LTG

More information

Fan Coil Units for Installation in False Floors

Fan Coil Units for Installation in False Floors The Innovation Company Fan Coil Units for Installation in False Floors xample: Type KB c D - 70435 Stuttgart, Grenzstraße 7 +49 (0711) 82 01-0, Fax +49 (0711) 82 01-720 Internet: http://www.ltg-ag.de -Mail:

More information

Cooling system cool wave R A new dimension in room cooling

Cooling system cool wave R A new dimension in room cooling Cooling system cool wave R A new dimension in room cooling D - 70435 Stuttgart, Grenzstraße 7 +49 (0711) 82 01-180, Fax +49 (0711) 82 01-720 Internet: http://www.ltg-ag.de E-Mail: info@ltg -AG.de LTG Incorporated

More information

LTG High Pressure Humidifier and Airwasher

LTG High Pressure Humidifier and Airwasher LTG Compacting Luftauslässe Power Screw Type CPS Für Compacting alle Einsatzgebiete dischargeoffinedust der Raumluft- and technik and short fibres Technical Documentation Function The LTG High Pressure

More information

LTG Air-Water Systems

LTG Air-Water Systems AIR TECH SYSTEMS Technical Brochure LTG Air-Water Systems Air conditioning system Indivent Ceiling installation Technical brochure Air conditioning system Indivent, ceiling installation LTG Comfort Air

More information

Compact Filter Unit Type CFU

Compact Filter Unit Type CFU Compact Filter Unit Type CFU 105 Corporate Drive, Suite E Spartanburg, SC 29303 PO Box 2889, Spartanburg, SC 29304 USA Tel: 864-599-6340 Fax: 864-599-6344 e-mail: info@ltg-inc.net Internet: http://www.ltg-inc.net

More information

LTG Air-Water Systems

LTG Air-Water Systems Technical Brochure LTG Air-Water Systems Decentralised ventilation unit FVPpulse-B Floor installation www.ltg.net LTG Comfort Air Technology Air-Water Systems Air Diffusers Air Distribution Content Page

More information

LTG Air-Water Systems

LTG Air-Water Systems Product Overview LTG Air-Water Systems Best air conditioning solutions for any room situation. Outstanding in performance and efficiency, comfort and acoustics. LTG Aktiengesellschaft Innovative Solutions

More information

LTG Air-Water Systems

LTG Air-Water Systems Technical Brochure LTG Air-Water Systems Induction units HFFsuite For hotel bedrooms, ceiling installation LTG Comfort Air Technology Content View of unit, application, installation/placement, function,

More information

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK SUPPLY AND EXTRACT AIR UNIT WITH HEAT EXCHANGER AND HEAT RECOVERY, SECONDARY AIR OPTION, FOR

More information

Ceiling air diffuser INDULTHERM INDULTHERM-e

Ceiling air diffuser INDULTHERM INDULTHERM-e Technical Information Ceiling air diffuser INDULTHERM INDULTHERM-e Effective cooling and heating with a diffuser Thermomechanical or electrical switching Draught-free air distribution for cooling down

More information

Polaris-I-60. active chilled beam. the future of space conditioning

Polaris-I-60. active chilled beam.   the future of space conditioning the future of space conditioning Polaris-I-60 active chilled beam Function Cooling and supply air with two-way air distribution Available with heating and integrated controls Application Offices, hotels,

More information

TopVent Design Handbook

TopVent Design Handbook TopVent Design Handbook Recirculation Units and Supply Air Units for Heating and Cooling High Spaces TopVent Content TopVent DHV Recirculation unit for heating high spaces TopVent NHV Recirculation unit

More information

KLIMA Active Chilled Beams

KLIMA Active Chilled Beams KLIMA 2 600 Active Chilled Beams Index Subject Page Index 1 Introduction 2 General description 3-4 Product features 5-6 Dimensions 7 Performance data 8-11 Section example Guide specifications 13 1 Introduction

More information

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams Integrated chilled beams Key figures Connections: 1x mm, 2x mm Airflow: 5-60 l/s Pressure range: 40 - Pa Size: 293 x 200 mm (WxH) Length: 1192 or 1792 mm Total effect: up to 1200W Cumulus is available

More information

Comfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W

Comfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W Comfort Ceiling Fan Coil System INDULVENT ec NEW Draught-free ambient air distribution with cooling capacity up to 2600 W Low sound power levels Only electrical, cooling water and condensate connections

More information

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation Cooling and heating systems Static cooling ceiling system SKS-/3 DS 10 E 01.010 Static cooling ceiling system SKS-/3 Main features Preliminary remarks / Applications 3 Main dimensions and materials 3 Construction

More information

Für Compacting alle Einsatzgebiete. Raumlufttechnik. High Pressure Humidifier and Airwasher Type HPH. Power Screw Type CPS. der dischargeoffinedust

Für Compacting alle Einsatzgebiete. Raumlufttechnik. High Pressure Humidifier and Airwasher Type HPH. Power Screw Type CPS. der dischargeoffinedust LTG Incorporated High Pressure Humidifier and Airwasher Type HPH LTG Compacting Luftauslässe Power Screw Type CPS Für Compacting alle Einsatzgebiete and der dischargeoffinedust Raumlufttechnik and short

More information

VENTILATION SYSTEM COMPONENTS. Product Overview

VENTILATION SYSTEM COMPONENTS. Product Overview VENTILATION SYSTEM COMPONENTS Product Overview » Air-conditioning technology a new dimension in architecture «Modern architecture sets particular challenges for innovative ventilation and airconditioning

More information

LTG Air-Water Systems

LTG Air-Water Systems Product Overview LTG Air-Water Systems Best air conditioning solutions for any room situation. Outstanding in performance and efficiency, comfort and acoustics. LTG Aktiengesellschaft Innovative Solutions

More information

We have some on stock... GEA MultiMAXX Prompt. Unit Heaters Data & Facts. GEA Heat Exchangers / HVAC Systems

We have some on stock... GEA MultiMAXX Prompt. Unit Heaters Data & Facts. GEA Heat Exchangers / HVAC Systems We have some on stock... GEA MultiMAXX Prompt Unit Heaters Data & Facts GEA Heat Exchangers / HVAC Systems Short Description/Overview of Capacity Quick solution for heating of industrial halls For more

More information

System architecture. Air treatment Index

System architecture. Air treatment Index System architecture Air treatment Index 88 Index Chilled-water air treatment units Type Range Cooling capacity, kw Heating capacity, kw Air flow, l/s Chilled-water terminal units Cassette Cabinet Concealed

More information

Fan Coil Unit CULTRA

Fan Coil Unit CULTRA Fan Coil Unit CULTRA Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...

More information

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort Application guide FLATAIR - FLCK/FLHK Providing indoor climate comfort MSL60E-0701 12-2006 Congratulations you have made a wise choice and we feel sure that it will meet your expectation INDEX CONTENTS

More information

Units for suspended ceilings

Units for suspended ceilings X X testregistrierung Units for suspended ceilings Type, hinged induced air grille, water connections Active chilled beam with two-way air discharge and horizontal heat exchanger, suitable for grid ceilings

More information

Units for suspended cei lings

Units for suspended cei lings . X X testregistrierung Units for suspended cei lings Type, hinged induced air grille, water connections Chilled Beams No. 09.2.432 Eurovent certification HYGIENISCH GETESTET V DI 6022 Tested to VDI 6022

More information

VERSO Air Handling Units

VERSO Air Handling Units Energy efficient solutions for profitable indoor climate VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P air handling units equipped with recuperation system

More information

Ceiling air diffuser INDULTHERM INDULTHERM-e

Ceiling air diffuser INDULTHERM INDULTHERM-e Technical Information Ceiling air diffuser INDULTHERM INDULTHERM-e Effective cooling and heating with a diffuser Thermomechanical or electrical switching Draught-free air distribution for cooling down

More information

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation Air handling units KLASIK Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation KLASIK air handling units Customer oriented and unique

More information

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply. Halton CSW Swirl comfort unit for ceiling installation The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply. A combined cooling, heating, and supply-air unit for flush

More information

AIR HANDLING UNITS MANDÍK

AIR HANDLING UNITS MANDÍK AIR HANDLING UNITS MANDÍK 2 CONTENTS MANDÍK, a. s. The Company... 3 Photo Gallery... 4 Unit Description... 6 Air handling unit parameters according to Eurovent... 7 Product Range of the Air Handling Units...

More information

Homepage > Products > Decentralised ventilation Systems > Vertical devices > Type FSL-V-ZUS. Type FSL-V-ZUS

Homepage > Products > Decentralised ventilation Systems > Vertical devices > Type FSL-V-ZUS. Type FSL-V-ZUS Homepage > Products > Decentralised ventilation Systems > Vertical devices > Type FSL-V-ZUS Type FSL-V-ZUS SECONDARY AIR UNIT FOR SUPPLY AIR, WITH HEAT EXCHANGER, FOR VERTICAL INSTALLATION ON AN EXTERNAL

More information

VERSO Air Handling Units

VERSO Air Handling Units VERSO Air Handling Units Energy efficient solutions for profitable indoor climate VERSO Air Handling Units VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P

More information

Cleanroom systems. Supply air ceiling and recirculated air ceiling OP. for operating rooms with low-turbulence displacement flow

Cleanroom systems. Supply air ceiling and recirculated air ceiling OP. for operating rooms with low-turbulence displacement flow Cleanroom systems Supply air ceiling and recirculated air ceiling OP. for operating rooms with low-turbulence displacement flow Best air management solutions through customized systems For more than 20

More information

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB 4,5 22,5 kw Air-conditioned server-racks for direct installation into the room technicalcatalogue T_CLSEVO_0113_GB INDEX HIGHLIGHTS... 3 PLANT TYPE... 3 GENERAL CHARACTERISTICS... 5 SERIES IDENTIFICATION...

More information

Technical Concept. Plenum Integrated Filter Fan PIFF 3-AC PIFF 3-EC

Technical Concept. Plenum Integrated Filter Fan PIFF 3-AC PIFF 3-EC Technical Concept Plenum Integrated Filter Fan PIFF 3-AC PIFF 3-EC Technical Concept Plenum Integrated Filter Fan Product Description The Plenum Integrated Filter Fan (PIFF) is a fan filter unit with integrated

More information

iq Star LYRA II chilled beam cassette

iq Star LYRA II chilled beam cassette iq Star LYRA II chilled beam cassette Key features Ventilation Heating and cooling Compact chilled beam Adjustable induction Flow Pattern Control Integrated control In option: Demand Controlled Ventilation,

More information

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:

More information

BTBa. FLUSHLINE Ventilated chilled beam for cooling, heating and ventilation. BTBa

BTBa. FLUSHLINE Ventilated chilled beam for cooling, heating and ventilation. BTBa FLUSHLINE Ventilated chilled beam for cooling, heating and ventilation BTBa CEILING UNIT FLUSHLINE BTBa FLUSHLINE BTBa is a complete climate system offering immense flexibility. Ideal for large areas with

More information

Use. Worth noting. Key figures. Installation. linx industries chilled beams. the beam is mounted on a standard T-support.

Use. Worth noting. Key figures. Installation. linx industries chilled beams. the beam is mounted on a standard T-support. 63 Use Lindab's supply air beam has a large cooling capacity and can therefore be used to advantage in rooms with substantial cooling requirements. In terms of appearance, looks similar to Professor. Polaris/Professor

More information

CBC - Active Chilled Beam. Halton CBC. Active Chilled Beam

CBC - Active Chilled Beam. Halton CBC. Active Chilled Beam Halton CBC Active Chilled Beam Combined cooling, heating, and supply air unit for flush installation within a suspended ceiling Well suited for spaces with high cooling loads and low humidity load Ideal

More information

Use. Worth noting. Key figures. Installation. linx industries chilled beams

Use. Worth noting. Key figures. Installation. linx industries chilled beams 71 Use Lindab's supply air beam has a large cooling capacity, uses one-way air injection and can therefore be used to advantage in rooms with small spaces and substantial cooling requirements. In terms

More information

Refrigerant R407C CW-AR. 2.4 to 3.1kW. Water Source Heat Pumps - Vertical Mounting Version Models 07 to to 2.7kW

Refrigerant R407C CW-AR. 2.4 to 3.1kW. Water Source Heat Pumps - Vertical Mounting Version Models 07 to to 2.7kW Refrigerant R407C CW-AR Water Source Heat Pumps - Vertical Mounting Version Models 07 to 12 2.4 to 3.1kW 1.9 to 2.7kW Some advantages... RAL 9010 painted cabinet 3-fan speeds G2 filter is supplied as

More information

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT 90% EFFICIENCY HIGHEST EFFICIENCY AIR HANDLING UNIT Packaged energy recovery solutions for Green Buildings Integrated Accumulator, controls and DX Cooling System CLEAN AIR SINCE 1963 Euroclima is a company

More information

KOG LN. Low Noise Chilled Water Cassettes Models 09, 12 & to 6.10kW to 5.10kW. 330 to 920 m3/h

KOG LN. Low Noise Chilled Water Cassettes Models 09, 12 & to 6.10kW to 5.10kW. 330 to 920 m3/h KOG LN Low Noise Chilled Water Cassettes 09, 12 & 18 1.70 to 6.10kW 1.58 to 5.10kW 330 to 920 m3/h KOG LN 9 / KOG LN 12 / KOG LN 18 Design Features Introduction The new low noise chilled water cassettes

More information

WOLF WARM AIR CURTAIN

WOLF WARM AIR CURTAIN TECHNICAL DOCUMENTATION WOLF WARM AIR CURTAIN TL-2 30m 3 /h TL-2 WARM AIR CURTAIN Additional silencer mat in the discharge section Attractive intake grille with rectangular perforations, self-centring

More information

COOLflow 4E PRODUCT RANGE

COOLflow 4E PRODUCT RANGE COOLflow 4E PRODUCT RANGE FREE AIR COOLING FROM THE FREE AIR SPECIALISTS GUARANTEED TO SIGNIFICANTLY REDUCE CARBON EMISSIONS & DELIVER ENERGY SPEND SAVINGS OF UP TO 95% The COOLflow 4E range has been developed

More information

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw COOLROW Close control air conditioners for In-Row installation Cooling Capacity: 14 61 Available in versions equipped with: - BLDC inverter scroll compressor on board of the unit - Chilled water feeding

More information

Chilled beam technology overview John Woollett 1, Jonas Åkesson 2 Swegon AB 1,2

Chilled beam technology overview John Woollett 1, Jonas Åkesson 2 Swegon AB 1,2 Chilled beam technology overview John Woollett 1, Jonas Åkesson 2 Swegon AB 1,2 john.woollett@swegon.se, jonas.akesson@swegon.se SUMMARY The main focus of the paper will be on active beam technology regarding

More information

Küba SF blastfreezer. High-performance air cooler for blast chilling and shock freezing

Küba SF blastfreezer. High-performance air cooler for blast chilling and shock freezing High-performance air cooler for blast chilling and shock freezing engineering for a better world GEA Heat Exchangers High-performance air cooler for blast chilling and shock freezing Large fin spacing

More information

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB Next P 6 112 kw COOLING 5 93 kw HEATING Heat pump air conditioners with upflow air delivery technicalcatalogue T_NXTP_0411_GB INDEX GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 4 MODEL IDENTIFICATION...

More information

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit MODEL: ACW200D ACW300D ACW400D ACW500D ACW600D ACW800D ACW900D ACW1000D ACW1200D ACW1400D ACWD-2006 ACWD_2006_Cover.indd 1 CEILING CONCEALED Chilled Water Fan Coils Unit 2006-5-25 17:24:07 Contents Main

More information

EASYAIR COMPACT DEVICE THE EASY WAY OF AIR HANDLING.

EASYAIR COMPACT DEVICE THE EASY WAY OF AIR HANDLING. EASYAIR COMPACT DEVICE THE EASY WAY OF AIR HANDLING. EASYAIR THE EASY WAY OF AIR HANDLING Independently VDI 6022 tested and certified down to the last detail The new generation of EASYAIR compact devices

More information

Swegon PACIFIC. Integrated chilled beam PACIFIC CHILLED BEAM KEY FIGURES

Swegon PACIFIC. Integrated chilled beam PACIFIC CHILLED BEAM KEY FIGURES Swegon PACIFIC Integrated chilled beam PACIFIC CHILLED BEAM The PACIFIC is a high performance chilled beam for installation in false ceilings. Built-in flexibility, designed to meet the needs of today

More information

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED EQV R-407C WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED Size Cooling Heating [kw] [kw] 5 1,9 2,2 7 2,4 2,5 9 2,6 2,5 15 3,3 3,2 17 3,7 3,7 REPLACE: BT02E008GB-01 The Versatemp EQV units

More information

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h PRODUCT DATA COMFORT 40 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 40 m /h COMFORT 40 Product description The Comfort 40 is an energy-efficient ventilation

More information

Cooling Towers. Energy-efficient solutions for open circuit, closed circuit and double-cell cooling towers.

Cooling Towers. Energy-efficient solutions for open circuit, closed circuit and double-cell cooling towers. ENGIE Refrigeration supplies the right cooling for every process: from efficient chillers and modular re-cooling systems to turnkey solutions such as refrigeration containers or modules. Efficiency, sustainability,

More information

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX Duct unit DUCTIMAX Medium available static pressure ducted hydronic units DUCTIMAX - 8 kw NEW PRODUCT JUNE 05 Performance and compactness in recessed ceiling installations ERGO Supervision Plus -pipe system

More information

Trench Heating Katherm QK

Trench Heating Katherm QK Trench Heating Katherm QK Tested acc. to: EN 16430 March 2015 EC technology: the ace up your sleeve New EC technology is a revolution in electronic drive technology. High output, yet whisper quiet, even

More information

QZHW Fan Coil Unit. Key features. Specifications

QZHW Fan Coil Unit. Key features. Specifications Key features High wall installation Cooling ( pipes) Low noise level Electrical heating coil ECM version for low energy consumption QZHW is a high wall fan coil unit available in sizes and many different

More information

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM 0,7 kw 5,2 kw 1,6 kw 10,2 kw 130 m 3 /h 830 m 3 /h SLIM SLIMxx0 vertical with cabinet bottom vertical Available also with feet SLIMxx8 SLIMxx5 SLIMxx4 SLIMxx9

More information

next DX.U.S* 052.Z2.H6.DC

next DX.U.S* 052.Z2.H6.DC next DX.U.S* 05.Z.H6.DC GENERAL CHARACTERISTICS Air conditioning unit with remote air cooled condenser, for computer rooms, any high-tech facility and offices. Units can run non-stop at 4x65 hours a year.

More information

Extreme industrial environments Air/water heat exchangers (roof-mounted, wall-mounted) Recooling system

Extreme industrial environments Air/water heat exchangers (roof-mounted, wall-mounted) Recooling system 3 Extreme industrial environments Air/water heat exchangers (roof-mounted, wall-mounted) Recooling system 3 04 eat exchangers One concept, two systems with very different operating methods Air/water heat

More information

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit. Fresh air unit ALB ALB it s simple and so easy! Air supplied through a heater and filter in a single unit. The ALB fresh air units from Helios provide comfortable room temperatures. Fresh outside air is

More information

CORRIGENDUM No.l to the Tender Dossier. Reconstruction of Judicial Academy Building in Belgrade Location - Republic of Serbia

CORRIGENDUM No.l to the Tender Dossier. Reconstruction of Judicial Academy Building in Belgrade Location - Republic of Serbia A* Ref. Ares(2018)3663039-10/07/2018 CORRIGENDUM No.l to the Tender Dossier Reconstruction of Judicial Academy Building in Belgrade Location - Republic of Serbia Publication reference: EuropeAid/139201/DD/WKS/RS

More information

Küba SG commercial

Küba SG commercial GEA Küba 42 Küba Blue Line : Specific advantages High performance air cooler for commercial applications with a large scope and complete capacity spectrum. Draw-through fans guide the air flow evenly through

More information

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit Fan Coil Unit 1 BOSCH Climate 000 Fan Coil Unit 2 Fan Coil Unit Introduction to Bosch Thermotechnology Bosch Thermotechnik GmbH is a leading supplier of resourceefficient heating products and hot water

More information

TopMaster Air Handling unit. Technical data

TopMaster Air Handling unit. Technical data Technical data Contents Page Description of the unit... 3 Design... 4 Technical data Size 030... 5 Size 0... 6 Accessories... 7 Controls... 9 Control functions... 10 Order codes... 11 Fläkt Woods 8180

More information

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation Air handling units KLASIK Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation KLASIK air handling units Customer oriented and unique

More information

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions Dehumidifiers for radiant cooling systems with heat recovery 50 The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area

More information

RoofVent Design Handbook

RoofVent Design Handbook RoofVent Design Handbook Supply and Extract Air Handling Units for Heating and Cooling High Spaces RoofVent RH RC RHC R Content RoofVent RH RC RHC R RoofVent RH Supply and extract air handling unit with

More information

VARICOOL Velum. System description/applications 4 Design and application 5 Planning and dimensioning 7 Technical features 8

VARICOOL Velum. System description/applications 4 Design and application 5 Planning and dimensioning 7 Technical features 8 VARICOOL Velum System description/applications 4 Design and application 5 Planning and dimensioning 7 Technical features 8 All legal and technical information was compiled to the best of our knowledge

More information

www.ecso-klimatechnik.de ECSO GMBH Wetterssteimstr. 53 D- 90471,.. Nurnberg, Deutschland e-mail: info@ecso-klimatechnik.de Tel/Fax: +49 (0) 911/818 9917 TABLE OF SYMBOLS OPERATING MODE OPTIONS VENTILATION

More information

Contents. Technical Description of the Air Handling Unit General, Specification Function, Functional Sections

Contents. Technical Description of the Air Handling Unit General, Specification Function, Functional Sections Room unit Contents Technical Description of the Air Handling Unit General, Specification... 146 Function, Functional Sections... 147 Control System Control Display, Airflow Control... 148 Temperature Control...

More information

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01 b cool manufacturers of air-conditioning equipment ltd BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION Ver. 1.01 Ver. 3.02 01_18 BCool# 1 brt c/h r407c / r410a

More information

LOW STATIC HYDRONIC DUCTED UNIT

LOW STATIC HYDRONIC DUCTED UNIT LOW STATIC HYDRONIC DUCTED UNIT PDWA-~AC SERIES PDWA(4R)-~-V-MEDC PDWA(4R)-~-V-MEEU PDWA(R)-~-V PDWA(R+1)-~-P Model cooling capacity( KW) at Medium Speed cooling capacity (KW) at Medium Speed cooling capacity

More information

CBH - Active Chilled Beam. Halton CBH. Active Chilled Beam

CBH - Active Chilled Beam. Halton CBH. Active Chilled Beam Halton CBH Active Chilled Beam Combined cooling, heating and supply air unit for exposed wall installation Well suited for hotel guest rooms with high requirements for thermal comfort and room acoustics

More information

Krantz. Multifunction exposed ceiling AVACS. Cooling and heating systems

Krantz. Multifunction exposed ceiling AVACS. Cooling and heating systems Krantz Multifunction exposed ceiling AVACS Cooling and heating systems DS 4170 E 07.16 Preliminary remarks and construction design Preliminary remarks The multifunction exposed ceiling AVACS is designed

More information

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP EVH R-407C WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP Size Cooling Heating [kw] [kw] 7 2.0 1.9 11 2.6 2.5 15 3.9 3.3 5.2 5.5 25 7.3 6.7 31 8.9 8.4 41 10.7 9.8 REPLACE: BT02E009GB-01 The Versatemp

More information

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam Halton CHH Active Chilled Beam Combined cooling, heating, and supply air unit for suspended ceiling / bulkhead installation Excellent suitability for hotel guest rooms with high requirements for thermal

More information

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS RAH 602 Ka + CF + GP 62 Above picture is only indicative and is not binding.

More information

VEX100 series Air handling units with cross-flow heat exchanger

VEX100 series Air handling units with cross-flow heat exchanger Product information - Version 6 VEX100 series Air handling units with cross-flow heat exchanger VEX140: 400-2200 m 3 /h VEX150: 700-3600 m 3 /h VEX160: 1100-5000 m 3 /h VEX170: 1400-8400 m 3 /h Contents

More information

Centrifugal air heaters hot water or electrical supply

Centrifugal air heaters hot water or electrical supply The economical solution with centralised production Individual adjustment in each room The most silent electric air heater to protect against frost or to heat large spaces A wide range of accessories Range:

More information

iq Star LYRA II chilled beam cassette

iq Star LYRA II chilled beam cassette Key features The LYRA II cassette is an active chilled beam for ventilation, cooling and heating. This diffusion system offers high flexibility thanks to the combination of Flow Pattern Control, Coanda

More information

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation Sinteso Cerberus PRO FDA241, FDA221 ASD Aspirating smoke detector Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation Patented technology Early

More information

NEW AR-L AR-C AND HIGH-CAPACITY LINEAR COOLING PANELS. Higher energy efficiency. Increased thermal comfort

NEW AR-L AR-C AND HIGH-CAPACITY LINEAR COOLING PANELS. Higher energy efficiency. Increased thermal comfort NEW AR-C AND HIGH-CAPACITY LINEAR COOLING PANELS Higher energy efficiency Increased thermal comfort Higher capacity than standard radiant ceilings Significant space savings Reduced new construction costs

More information

photo by PFC Price Fan Column

photo by   PFC Price Fan Column photo by www.mrobinsonphoto.com PFC Price Fan Column Typical Applications The Price Fan Column (PFC) is a vertical fan unit designed to discharge into a raised access floor plenum. The unit s compact design

More information

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES Dehumidifiers for radiant cooling systems with heat recovery The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area

More information

Trench Heating. Katherm QK with EC Technology

Trench Heating. Katherm QK with EC Technology Trench Heating Katherm QK with EC Technology Unbeatable advantages Katherm QK at a glance Details Choice of grilles Controller models Heat output Dimensions Benefits for you! Calculation program (ext.

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING

More information

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: , DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: +971-6-5432526, Fax#: +971-6-5432415, Email: dolcool@emirates.net.ae, web site: www.dolphinheattransfer.com NOMENCLATURE: INTRODUCTION DOLCOOL branded

More information

Fresh Air Ventilation

Fresh Air Ventilation Air Handling Units The new (AHU s) utilise Mr Slim Power Inverter heat pump technology, Lossnay heat recovery technology and an integrated controls system making them highly advanced and efficient. Key

More information

Fresh Air Ventilation

Fresh Air Ventilation Air Handling Units The new (AHU s) utilise Mr Slim Power Inverter heat pump technology, Lossnay heat recovery technology and an integrated controls system making them highly advanced and efficient. Key

More information

ADRIATIC VF. Active chilled beam with cooling, heating and ventilation QUICK FACTS

ADRIATIC VF. Active chilled beam with cooling, heating and ventilation QUICK FACTS Active chilled beam with cooling, heating and ventilation QUICK FACTS The ADRIATIC VF is a chilled beam with integrated recirculated air opening in the face plate. Air is discharged into the room along

More information

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units Advance Product Data 42WKN Hydronic Fan Coil Units 3 4 to 2 1 2 Tons UNIT SIZES 004-010 UNIT SIZES 016,020 The new Carrier Hydronic Cassette offers a modern solution for a wide variety of small and medium

More information

SUSPENDED AIR HANDLING UNIT WITH ROTARY HEAT EXCHANGER

SUSPENDED AIR HANDLING UNIT WITH ROTARY HEAT EXCHANGER SUSPENDED AIR HANDLING UNIT WITH ROTARY HEAT EXCHANGER Energy Recovery Ventilation Specialist Beijing Holtop Artificial Environment Technology Co., Ltd ISO 9001: 2000 Approved Company COMPANY BRIEF INTRODUCTION

More information

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h PRODUCT DATA COMFORT 5000 BY NILAN Ventilation & passive heat recovery Commercial Passive heat recovery Ventilation < 5300 m 3 /h COMFORT 5000 The Comfort 5000 is a ventilation unit suitable for central

More information

Roof top SPACE RPC 450Z R407C M011

Roof top SPACE RPC 450Z R407C M011 Roof top SPACE RPC 450Z R407C M011 Page : 1 / 5 Independant roof mounted unit, cooling only, ready to be installed, designed for air conditioning of large volumes for industrial or commercial use. As per

More information

next evo cw next evo cw rcgroupairconditioning

next evo cw next evo cw rcgroupairconditioning : Close control air conditioners for chilled water feeding with upflow or downflow air delivery Cooling Capacity: 6,2 248,0 rcgroupairconditioning E C CHILLED WTER UP FLOW DOWN FLOW MIN FETURES Chilled

More information