1 SUSPENDED AIR HANDLING UNIT WITH ROTARY HEAT EXCHANGER Energy Recovery Ventilation Specialist Beijing Holtop Artificial Environment Technology Co., Ltd ISO 9001: 2000 Approved Company

2 COMPANY BRIEF INTRODUCTION TO COMPANY ENERGY RECOVERY VENTILATION SPECIALIST Holtop is dedicated to the research and technology development in the filed of indoor air quality. It is the leading company in China who professionally produces heat recovery ventilation system. Covering a land of square meters, Holtop was created in May, 2002 furnished with first-class plants and equipments. Through innovation, it developed its own key components like plate and rotary heat exchangers for various heat & energy recovery systems. It provides now full lines of products covering 5 series and 98 specifications which can basically satisfy the needs of various airflows and installations worldwidely. Holtop is trusted by the users for its advanced technology, superb product quality and all-around services. By the end of year 2006, Holtop has supplied successfully to over 3000 customers in the domestic market and exported its products to Japan, Korea, Russia, Italy, Belgium, Australia, New Zealand, etc. Let's join together to contribute to our commitment of energy saving and pollution reduction. 2

3 CONTENTS BRIEF INTRODUCTION TO COMPANY 02 UNDERSTANDING MODEL NUMBER AND AIRFLOWS 04 SPECIFICATIONS AND DIMENSIONS 05 MAIN FEATURES AND COMPONENTS 06 MAIN FEATURES AND COMPONENTS 07 INSTALLATION, OPERATION AND MAINTENANCE 08 3

4 UNDERSTANDING MODEL NUMBER AND AIRFLOWS HDK-02 G P 6 S Y Type of AHU, Z for left and Y for right S- Humidifying Row number of cooling/heating coil, 3/6 rows available P-Plate heat exchanger, R-Rotary heat exchanger Class of filter: G for Coarse, F for Medium Nominal airflow multiplied by 1000m3/h Holtop suspended energy recovery AHU Judging left or right type Look at the direction of supply air, it s left type if water pipes on the left; otherwise, it s a right type. For standard AHU, service door, wiring port and water pipe of heating/cooling coils locate at the same side. OA RA Left EA SA Right Suitable airflow Model Suitable airflow HDK m 3 /h~1700m 3 /h HDK m 3 /h~2800m 3 /h HDK m 3 /h~3200m 3 /h HDK m 3 /h~3900m 3 /h HDK m 3 /h~5200m 3 /h 4

5 SPECIFICATIONS AND DIMENSIONS Specifications Model Airflow (m3/h) External pressure of supply fan (Pa) External pressure of exhaust fan (Pa) Temp. Eff.(%) Noise db(a) Volt. (V) Current (A) Rated N. W. power (Kg) (W) HDK HDK Up to 70% HDK HDK Dimensions H H1 H2 L L1 L2 L3 EA W1 RA W OA W2 SA Model L L1 L2 L3 W W1 W2 H H1 H2 HDK-012, HDK HDK-030, HDK

6 MAIN FEATURES AND COMPONENTS Main features Equipped with supply fan and exhaust fan, brings in fresh air and exhausts out stale indoor air as well. Equipped with rotary heat exchanger, recovers energy from outgoing indoor air, to save operating cost to the max. Thin height, easily installed in the ceiling space. Housing construction Double skin panel 25mm thick, inner skin made of galvanized steel sheet, outer skin color steel sheet, between skins is sandwiched with high density fireproof PU with thermal coefficient below W/m. High air tightness Double inlaid sealing system to tightly join the framework and panels, total air leakage rate below 3%. Supply fan and exhaust fan Outer rotor motor, direct driven centrifugal fan, dynamic balance, compact and low noise level. Filter Plate type(g4) coarse filter as standard configuration. (Bag filter F5~F8 available as per request of customer). Draw-push installation, easy maintenance. 6

7 MAIN FEATURES AND COMPONENTS Rotary heat exchanger Holtop total heat exchanger (enthalpy recovery wheel) is made of aluminum foil coated with 3A molecular sieve, which enables the wheel to exchange both temperature and humidity, in another word, to recover both sensible and latent heat. Working principle Rotary heat exchanger is composed of heat wheel, case, drive system and sealing parts. The heat wheel rotates powered by the drive system. When outdoor air (OA) passes through half of the wheel, return air (RA) passes through reversely the rest half of the wheel. In this process, about 70% to 90% energy contained in the return air (RA) can be recovered to supply air (SA) to indoor. Technical features Molecular sieve coating 3A molecular sieve coated aluminum wheels have an excellent capacity of moisture absorption even under high temperature, high airspeed and low humidity, and can expel harmful odor gases due to the selective absorption characteristics. Double sealing system Unique design of double sealing system ensure the air leakage below 0.5%. The special soft and dense material achieves better sealing effect and is 3-5 times longer life than ordinary materials. Double purge sector The double purge sector minimizes carryover from the exhaust air into the supply air stream. If the correct pressure difference is provided ( Pa), the rate of dust, gases etc. carried over from exhaust air into the supply air is below 0.3%. Self-cleaning The wheel has high self-cleaning effect under normal conditions due to the continuously changing direction of air flow through the wave type channels of the wheel. 7

8 INSTALLATION, OPERATION AND MAINTENANCE Installation 1. For maintenance purpose, leave enough space around the service door and water ports. Optimal space should be bigger than the length of the heating/cooling coil. Least space should be enough for take-down operation of filters. 2. AHU shall be horizontally installed under ceiling 150~200mm. Shock absorber is required between suspender and lugs. Ceiling bolt should be at least M14 Nut Cushion Underframe Cushion Nut 3. Use seal tape for drainpipe to ensure smooth draining. Connect as per following diagram. AHU H=Max press undertake(mm)+50mm 4. Clean all the water paths before connecting them to the unit. Make gentle connection in order to protect the coil. Weight of valves, pipes and other components beside the AHU should not be borne on the AHU. 5. Use soft fittings to connect the air inlet/outlet of unit and ducts. 6. Supply air should not be higher than 80,otherwise, please inform us before ordering so as to take related measures. 7. AHU housing should be well earthed. Operation and maintenance 1. AHU is powered by TN-S power supply system, i.e. AC3~380V+N+PE. 2. Check and make sure motor runs at right direction and freely. Run the unit after all the electric parts are checked without fault by a professional. 3. Commissioning is required before putting the equipment into use. Motors should be running under rated electric current. 4. Cooling & heating coil should use clean demineralized water as medium, working pressure 1.2MPa. 5. Drain out the water in the coil in winter, and blow away the remains water as far as possible. In case remains water can not be blew away, inject antifreeze into the coil. 6. Examine the filter regularly, clean or replace it if resistance comes to the end resistance. Air-dry the washed filter totally before reuse. 7. Fully clean or maintain the unit after each 1 or 2-year operation. Clean the coils using compressed air or high pressure water. 8

9 Data is subject to changes without notification due to product improvement Beijing Holtop Artificial Environment Technology Co., Ltd Factory address : No.158 Hanjiachuan Road, Haidian District, Beijing China International marketing center Address: Room Industrial Plaza, Tina An Hi-Tech Ecological Park, No. 730 Yingbin Road, Panyu District, Guangzhou, China Tel: Fax: Website: contact@holtop.com

Beijing Holtop Artificial Environment Technology Co., Ltd

Beijing Holtop Artificial Environment Technology Co., Ltd Heat recovery ventilators Energy recovery ventilators Rotary heat exchangers Air handling units Beijing Holtop Artificial Environment Technology Co., Ltd ISO9001:2000 Approved company ENERGY RECOVERY VENTILATION

More information

Mystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV)

Mystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV) Mystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV) 1 Contents Why Heat Recovery Ventilator(HRV) is required Type of Heat Recovery Ventilator Feature of MITSUBISHI ELECTRIC Lossnay

More information

EU Air Handling Units with SEMCO EXCLU-SIEVE

EU Air Handling Units with SEMCO EXCLU-SIEVE EU Air Handling Units with SEMCO EXCLU-SIEVE The acquisition of US based Semco has given us the opportunity to include a new range of rotary heat exchangers in our EU air handling unit range. Hygienic

More information

39G Air Handling Unit

39G Air Handling Unit 39G Air Handling Unit Air flow: 2000 ~ 60000 m³/h The Manufacturer reserves the right to change any produt specifications without prior notices Version: Supersede: Effective Date: CAT_39G_E-1307_02 CAT_39G_E-1205_01

More information

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU) AIR HANDLERS Central Station (CS3) (Modular AL Frame AHU) Roof Mounted (RT) CONTENTS 1. CS3 Modular Aluminium Frame AHU : Unit Types 2. Casing Structure 3. Blowers and Drives 4. Coils 5. Options and Accessory

More information

THE PROMISE THE PROOF HEATEX AIR-TO-AIR HEAT EXCHANGERS

THE PROMISE THE PROOF HEATEX AIR-TO-AIR HEAT EXCHANGERS E THE PROMISE THE PROOF HEATEX AIR-TO-AIR HEAT EXCHANGERS ROTARY HEAT EXCHANGERS Heatex offers a broad range of rotary heat exchangers covering the complete application span from small residential installations

More information

Material and rotor description.

Material and rotor description. Material and rotor description. Why we use aluminum series 8000? Due the very good manufacturing characteristics and resistance against corrosion AMARANT has chosen to use the 8000 series alloy both for

More information

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT 90% EFFICIENCY HIGHEST EFFICIENCY AIR HANDLING UNIT Packaged energy recovery solutions for Green Buildings Integrated Accumulator, controls and DX Cooling System CLEAN AIR SINCE 1963 Euroclima is a company

More information

MODULAR AIR HANDLING UNIT. Models: FAC / FMC / FBC

MODULAR AIR HANDLING UNIT. Models: FAC / FMC / FBC MODUAR AIR HANDING UNIT Models: FAC / FMC / FBC Contents Product Nomenclature... 2 Features... 4 Engineering Specifications... 13 Cooling Coil Performance Chart... 13 Heating Coil Performance Chart...

More information

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit Fan Coil Unit 1 BOSCH Climate 000 Fan Coil Unit 2 Fan Coil Unit Introduction to Bosch Thermotechnology Bosch Thermotechnik GmbH is a leading supplier of resourceefficient heating products and hot water

More information

ASHRAE Region VI CRC Track III: Session 3 Ventilation Energy Recovery. Steven T. Taylor, PE Principal Taylor Engineering

ASHRAE Region VI CRC Track III: Session 3 Ventilation Energy Recovery. Steven T. Taylor, PE Principal Taylor Engineering ASHRAE Region VI CRC Track III: Session 3 Ventilation Energy Recovery Steven T. Taylor, PE Principal Taylor Engineering This program is registered with the AIA/CES for continuing professional education.

More information

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation Air handling units KLASIK Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation KLASIK air handling units Customer oriented and unique

More information

HRV Brochure. Heat Recovery Ventilation

HRV Brochure. Heat Recovery Ventilation HRV Brochure Heat Recovery Ventilation The Importance of Ventilation In todays hi tech world, ventilation is more important than ever before. Gone are the days when we relied on natural ventilation with

More information

AIR HANDLING UNITS ZHK 2000

AIR HANDLING UNITS ZHK 2000 AIR HANDLING UNITS ZHK 2000 Standard execution - ZHK2000 S Inner skin: 1,00mm galvanized sheet Outer skin: 0,70mm galvanized sheet with additional surface coating in plastic Industrial execution - ZHK2000

More information

YAH Series Air Handling Units

YAH Series Air Handling Units YAH Product Features Johnson Controls YORK YAH ceiling mounted cabinet fan coil units are terminal points of central airconditioning systems. They are designed for fresh air units or to cool, heat, humidify

More information

YAH SERIES FAN COIL UNITS

YAH SERIES FAN COIL UNITS YAH Series Fan Coil Units Johnson Controls YORK YAH ceiling mounted cabinet fan coil units are terminal points of central air-conditioning systems. They are designed for fresh air units or to cool, heat,

More information

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit MODEL: ACW200D ACW300D ACW400D ACW500D ACW600D ACW800D ACW900D ACW1000D ACW1200D ACW1400D ACWD-2006 ACWD_2006_Cover.indd 1 CEILING CONCEALED Chilled Water Fan Coils Unit 2006-5-25 17:24:07 Contents Main

More information

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9 ERV/ HRV CONTENTS Horizontal rotor heat recovery ventilation unit RH 5 Vertical rotor heat recovery ventilation unit RV 9 Suspended plate heat recovery ventilation unit CFP Horizontal plate heat recovery

More information

Double Skin Air Handling Units

Double Skin Air Handling Units Double Skin Air Handling Units With Screwless Cabinets Engineered to Deliver High Indoor Air Quality Double Skin Air Handling Units from the Experts Blue Star has over six decades of experience in offering

More information

Heat pump and energy recovery systems

Heat pump and energy recovery systems SBS5311 HVACR II http://ibse.hk/sbs5311/ Heat pump and energy recovery systems Ir. Dr. Sam C. M. Hui Faculty of Science and Technology E-mail: cmhui@vtc.edu.hk Oct 2017 Contents Basic concepts Air-to-air

More information

TEVHR. Heat Recovery Ventilator

TEVHR. Heat Recovery Ventilator TEVHR Heat Recovery Ventilator Contents Teknogen Who we are, what we do? TEVHR... 1 Unit Specifications... 2 Performance Data... 3 Technical Specification... 5 Components... 6 Dimensions... 7 Duct Connection

More information

Economical, Flexible, Advanced Performance. Ventilation and Dehumidification for Healthy IAQ

Economical, Flexible, Advanced Performance. Ventilation and Dehumidification for Healthy IAQ Economical, Flexible, Advanced Performance Ventilation and Dehumidification for Healthy IAQ CompleVent the Energy Conserving, Cost-Efficient Way to Meet ASHRAE Standards Today s focus on indoor air quality

More information

GUIDE SPECIFICATIONS FOR AIR HANDLING UNITS VENTILATION UNITS & HEAT RECOVERY UNITS

GUIDE SPECIFICATIONS FOR AIR HANDLING UNITS VENTILATION UNITS & HEAT RECOVERY UNITS S FOR AIR HANDLING UNITS VENTILATION UNITS & HEAT RECOVERY UNITS VAYHAN AIR CONTROLS PVT. LTD. G-1, Park View Residency, Patwari Enclave Gandhi Nagar (IDPL), Hyderabad 500 037. INDIA Phone: +91-40-2372

More information

SAFETY AND INSTALLATION MANUAL MODEL 8100

SAFETY AND INSTALLATION MANUAL MODEL 8100 SAFETY AND INSTALLATION MANUAL ENERGY RECOVERY VENTILATORS MODEL 8100 Provides year-round fresh air Recovers 77% of the apparent heating or cooling energy from the exhausted air See Warnings Page 3 Table

More information

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:

More information

Indoor Air Quality. For assured. Double Skin Air Handling Units

Indoor Air Quality. For assured. Double Skin Air Handling Units Double Skin Air Handling Units INTL-31-OCT 06-R0 CI680512 For assured Indoor Air Quality. For more information, please contact BLUE STAR LIMITED, International Division, Band Box House, 4th Floor, Dr.

More information

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP EVH R-407C WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP Size Cooling Heating [kw] [kw] 7 2.0 1.9 11 2.6 2.5 15 3.9 3.3 5.2 5.5 25 7.3 6.7 31 8.9 8.4 41 10.7 9.8 REPLACE: BT02E009GB-01 The Versatemp

More information

Double Skin Air Handling Units

Double Skin Air Handling Units Double Skin Air Handling Units With Screwless Cabinets Engineered to Deliver High Indoor Air Quality Double Skin Air Handling Units from the Experts Blue Star has over six decades of experience in offering

More information

AIR COOLED ROOFTOP UNITS, COOLING CAPACITY FROM 50 TO 240 kw, AIRFLOW FROM TO m3/h

AIR COOLED ROOFTOP UNITS, COOLING CAPACITY FROM 50 TO 240 kw, AIRFLOW FROM TO m3/h COMFORT ROOFTOP UNITS AIR COOLED ROOFTOP UNITS, COOLING CAPACITY FROM 50 TO 240 kw, AIRFLOW FROM 10000 TO 45000 m3/h climaveneta.com COMFORT ROOFTOP UNITS ENGINEERED FOR MAXIMUM EFFICIENCY AND VERSATILITY

More information

CHAPTER 4. HVAC DELIVERY SYSTEMS

CHAPTER 4. HVAC DELIVERY SYSTEMS CHAPTER 4. HVAC DELIVERY SYSTEMS 4.1 Introduction 4.2 Centralized System versus Individual System 4.3 Heat Transfer Fluids 4.4 CAV versus VAV Systems 4.5 Common Systems for Heating and Cooling 4.6 Economizer

More information

Heat Recovery Units. Heat Recovery 1

Heat Recovery Units. Heat Recovery 1 Heat Recovery Units Heat Recovery 1 Heat Recovery Unit Why? A heat recovery unit (HRU) can help make mechanical ventilation more cost effective by reclaiming energy from exhaust airflows. HRUs use air-to-air

More information

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions Dehumidifiers for radiant cooling systems with heat recovery 50 The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area

More information

Put the V back in HVAC

Put the V back in HVAC Put the V back in HVAC V is for Ventilation A system or means of providing fresh air. Webster New Collegiate Dictionary Benjamin Franklin so unwholesome as air in a closed room that has been often breathed

More information

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans. Geniox.

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans. Geniox. Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans Geniox Quick guide Copyright: Systemair A/S, 1. edition 2017. We accept no liability

More information

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation Air handling units KLASIK Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation KLASIK air handling units Customer oriented and unique

More information

GHE Dehumidifiers for radiant cooling systems with heat recovery

GHE Dehumidifiers for radiant cooling systems with heat recovery Dehumidifiers for radiant cooling systems with heat recovery The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area

More information

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01 b cool manufacturers of air-conditioning equipment ltd BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION Ver. 1.01 Ver. 3.02 01_18 BCool# 1 brt c/h r407c / r410a

More information

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT AIR TREATMENT ReCOOLER HP ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT Energy efficiency the essence of our solutions All our research, development

More information

Modular Air Handling Unit

Modular Air Handling Unit MAHUs are modular so that they have the flexibility to add components as required. The 3rd generation Midea MAHU adapts unitary structure design, more outstanding cold-bridge free performance, lower air

More information

AIR CONDITIONER PERFORMANCE RATING

AIR CONDITIONER PERFORMANCE RATING HPRATE V5.1 AIR CONDITIONER PERFORMANCE RATING by G.L. Morrison MechLab The University of New South Wales.EDU.AU September 2012 Version 5.1 HPRATE 5 Air Conditioner Performance Rating 1 HPRATE AIR CONDITIONER

More information

COOLING and DE-HUMIDIFICATION WITHOUT USING REFRIGERANTS

COOLING and DE-HUMIDIFICATION WITHOUT USING REFRIGERANTS COOLING and DE-HUMIDIFICATION WITHOUT USING REFRIGERANTS THE DAWN OF A NEW ERA Political and ecological pressures over the past few years, have led to a change of emphasis in the design of fully air-conditioned

More information

Air flow m3/h

Air flow m3/h Air-Handling Unit 9XT Air flow 000 00000m/h *EUROVENT Certification *50mm double skins *Excellent casing insulation and strength *Flexible selection *Excellent Cooling Performance *Quiet Operation *Reliable

More information

Air is our element. energy recovery our passion. Rotors overview. Quick guide GOST VDI 6022

Air is our element. energy recovery our passion. Rotors overview. Quick guide GOST VDI 6022 Rotors overview Quick guide GOST VDI 622 Rotors overview Rotor type Heat recovery Preferred application Wave heigh Thickness of material Condensations Rotor P/PT [ C] 1% Summer Winter 7 1 1-1 - [g/kg]

More information

PRODUCT CATALOGUE THE PROMISE THE PROOF HEATEX AIR-TO-AIR HEAT EXCHANGERS

PRODUCT CATALOGUE THE PROMISE THE PROOF HEATEX AIR-TO-AIR HEAT EXCHANGERS PRODUCT CATALOGUE THE PROMISE THE PROOF HEATEX AIR-TO-AIR HEAT EXCHANGERS HEATEX THE COMPANY Heatex is a global manufacturer of air-to-air heat exchangers. The company was founded in the 60 s, and incorporated

More information

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini... Contents How to choose Recovery Ventilation type?............................................3 How do HRV, ERV and TRV Systems work?............................................4 Types of installations..............................................................5

More information

Mikael Börjesson Product manager. Commercial air handling units Ventilation functionality Building management system integration

Mikael Börjesson Product manager. Commercial air handling units Ventilation functionality Building management system integration Mikael Börjesson Product manager Commercial air handling units Ventilation functionality Building management system integration Topics Presentation of the new generation of compact air handling units,

More information

Centeral Station Air Handling Unit

Centeral Station Air Handling Unit Centeral Station Air Handling Unit CA Series www.windind.com www.windind.com The product range includes double skinned Air Handling Units, double skinned Fan Coil Units, and custom designed packaged roof

More information

GHE. Dehumidifiers for radiant cooling systems with heat recovery. Display

GHE. Dehumidifiers for radiant cooling systems with heat recovery. Display GHE Dehumidifiers for radiant cooling systems with heat recovery Display The dehumidifiers with heat recovery of high efficiency series GHE were designed to provide dehumidification and fresh air in a

More information

AHU Plus. DX Air Handling Units

AHU Plus. DX Air Handling Units AHU Plus DX Air Handling Units AHU Plus DX DX Air Handling Units AHUPlusDX-TH: DX Air Hadling Unit with 100% Fresh Air AHUPlusDX -IGK: DX Air Hadling Unit with 100% Fresh Air and Heat Recovery AHUPlusDX-KH:

More information

VERSO Air Handling Units

VERSO Air Handling Units Energy efficient solutions for profitable indoor climate VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P air handling units equipped with recuperation system

More information

Custom Air Handler Solutions Custom Units to Meet Your Unique Design Needs

Custom Air Handler Solutions Custom Units to Meet Your Unique Design Needs Custom Units to Meet Your Unique Design Needs Engineered for flexibility and performance Contents Horizontal Configuration....1 Horizontal with Standard Economizer Configuration...2 Stacked Configuration...3

More information

Double Skin Casing Air Handling Units

Double Skin Casing Air Handling Units Double Skin Casing Air Handling Units Double wall with 25 mm insulation Modular design for clean process application flexibility all the requirements 2,000 40,000 CFM AUTUMN Air Handling Units incorporate

More information

DES CHAMPS PRODUCTS 85% 4,400 CFM

DES CHAMPS PRODUCTS 85% 4,400 CFM DES CHAMPS PRODUCTS Saves up to 85% of the heat from exhaust airstream Removes pollutants before they accumulate Transfers heat energy in winter/cool energy in summer Low cost Capacities up to 4,400 CFM

More information

MECHANICAL VENTILATION

MECHANICAL VENTILATION MECHANICAL VENTILATION Natural and Mechanical Systems Four (4) possible combinations of natural and mechanical ventilations tions are as follows; Natural inlet and outlet; utilizing open able windows,

More information

» WITH REGASORP ROTARY HEAT EXCHANGER

» WITH REGASORP ROTARY HEAT EXCHANGER AIR TREATMENT eq AIR HANDLING UNITS REGASORP» WITH REGASORP ROTARY HEAT EXCHANGER eq WITH REGASORP ROTARY HEAT EXCHANGER REDUCES COST UP TO 50% Two of the most important factors affecting indoor air climate

More information

Whole Home Heat Recovery Ventilation

Whole Home Heat Recovery Ventilation Whole Home Heat Recovery Ventilation Lossnay VL220. Clean Fresh Air; for a Healthier, Drier and Warmer Home. Balanced Pressure Home Ventilation. Made in Japan, Designed for New Zealand Conditions. Lossnay

More information

AIR HANDLING UNITS MANDÍK

AIR HANDLING UNITS MANDÍK AIR HANDLING UNITS MANDÍK 2 CONTENTS MANDÍK, a. s. The Company... 3 Photo Gallery... 4 Unit Description... 6 Air handling unit parameters according to Eurovent... 7 Product Range of the Air Handling Units...

More information

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES Dehumidifiers for radiant cooling systems with heat recovery The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area

More information

The ultimate in air handling units: directly and indirectly fired

The ultimate in air handling units: directly and indirectly fired AHU The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake

More information

EHH SERIES DRAW THROUGH FAN COILS CFM

EHH SERIES DRAW THROUGH FAN COILS CFM EHH SERIES DRAW THROUGH FAN COILS 400-5000 CFM TABLE OF CONTENTS TABLE OF CONTENTS 2 INTRODUCTION 3 GUIDE SPECIFICATIONS 4 UNIT OVERVIEW 6 TECHNICAL DATA 8 DIMENSIONS 10 COMPUTER SELECTION 11 GEMCOOL PROFILE

More information

Why should you opt for ENTHALPY. Wheels for your. AHUs. ERVs. (Energy Recovery Ventilators) (Air Handling Units) from

Why should you opt for ENTHALPY. Wheels for your. AHUs. ERVs. (Energy Recovery Ventilators) (Air Handling Units) from Why should you opt for ENTHALPY Wheels for your AHUs (Air Handling Units) & ERVs (Energy Recovery Ventilators) from Benefits of an ERV (Energy Recovery Ventilator) over a HRV (Heat Recovery Ventilator)

More information

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts GTIP60 ISO GT Series, Inch Pounds 60 Hz GT010070 (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts Rev: 903 Rev 1 Revisions: 31103 Changed HZ dwg to field convertible 5902 changed Unit

More information

DAZZLE TM series Cassette Type Fan Coil Unit. FC-NHDU4 Cassette Type Fan Coil Unit 340~2380 m 3 /h

DAZZLE TM series Cassette Type Fan Coil Unit. FC-NHDU4 Cassette Type Fan Coil Unit 340~2380 m 3 /h DAZZLE TM series Cassette Type Fan Coil Unit FC-NHDU4 Cassette Type Fan Coil Unit 340~380 m 3 /h Cassette Type Fan Coil Unit Casing Unit Features FC-NHDU4 series is the cassette type fan coil unit of Climaveneta.

More information

The ultimate in air handling units: directly and indirectly fired

The ultimate in air handling units: directly and indirectly fired KLIMAT The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake

More information

INDUSTRIAL DEHUMIDIFIERS. Advanced range of compressor and desiccant dehumidifiers. Dehumidification and drying

INDUSTRIAL DEHUMIDIFIERS. Advanced range of compressor and desiccant dehumidifiers. Dehumidification and drying INDUSTRIAL DEHUMIDIFIERS Advanced range of compressor and desiccant dehumidifiers Dehumidification and drying To room From room Fan Regeneration heater Dry process air Regeneration air Regeneration area

More information

Indholdsfortegnelse. Danvent Air Handling Units SERVICE MANUAL

Indholdsfortegnelse. Danvent Air Handling Units SERVICE MANUAL Indholdsfortegnelse Danvent Air Handling Units SERVICE MANUAL Service Servicing of the Air Handling Unit Your ventilation system is equipped with a Danvent Air Handling Unit (AHU) which will contribute

More information

Rotary heat exchangers

Rotary heat exchangers Rotary heat exchangers for Heat Recovery in Ventilation Systems Handbook for Design, Installation and Operation Content The advantages of rotary heat exchangers 2. General principle of rotary heat exchangers.2

More information

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution use Air flow rate: 500 to 8500 m 3 /h is a PLUG & PLAY dual-flow ventilation unit equipped with a highly

More information

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC AQB09JJ6WC_IM_E_2585 2006.4.17 4:26 PM Page 17 INSTALLATION MANUAL Indoor Unit AQB09JJWC AQB12JJWC Outdoor Unit UQB09JJWC UQB12JJWC ENGLISH FRANÇAIS ESPAÑOL Split-type Air Conditioner (Cooling and Heating)

More information

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

Compact, Self-Contained unit that offer low installation cost plus dependable performance. 0 Compact, Self-Contained unit that offer low installation cost plus dependable performance. From carrier s excellence in engineering come a new, compact of single package horizontal and vertical water

More information

Air Handling Units. Geniox. Quick guide

Air Handling Units. Geniox. Quick guide Air Handling Units Geniox Quick guide Copyright: Systemair A/S, 2. edition 2018. We accept no liability for printing errors or alterations of products. The dimensions and data used in this leaflet are

More information

Residential Heat & Energy Recovery

Residential Heat & Energy Recovery Residential Heat & Energy Recovery Aeromatic Series Standard Residential HRV/ERV 95-215 CFM 2 Discover Heat & Energy Recovery A tightly built, high-performance home is a great way to conserve energy and

More information

Enthalpy Wheel and its Application in Air Conditioning

Enthalpy Wheel and its Application in Air Conditioning Enthalpy Wheel and its Application in Air Conditioning Sathyanath M1, Sourav R2 1 2 Student, Dept of Mechanical Engineering, North Malabar Institute of Technology, Kanhangad, Kerela, India Student, Dept

More information

Rotors overview. Quick guide GOST VDI 6022

Rotors overview. Quick guide GOST VDI 6022 Rotors overview Quick guide GOST VDI 622 Rotors overview Rotor type Heat recovery Preferred application Wave heigh Thickness of material Condensations Rotor P/PT [ C] % Summer Winter - - [g/kg] 5 15 only

More information

The ultimate in air handling units: directly and indirectly fired

The ultimate in air handling units: directly and indirectly fired AHU The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake

More information

Bill McCullough. Director ERV Products. Dallas, TX

Bill McCullough. Director ERV Products. Dallas, TX Bill McCullough Director ERV Products Dallas, TX TOPICS 1. ERV Definition & Benefit 2. Indoor Air Quality 3. Energy Efficiency 4. ERV Technology & Operation 5. Stand-Alone ERVs 6. Compact ERVs What is

More information

AIR HANDLING UNITS. Revision AG 16-07

AIR HANDLING UNITS. Revision AG 16-07 AIR HANDLING UNITS UNIC sal is equipped to produce a wide range of COOLER Air conditioning and Refrigeration units, conforming to the international standards and works continually to improve its products

More information

Review on Waste Heat Recovery Techniques in Air Conditioning Application

Review on Waste Heat Recovery Techniques in Air Conditioning Application International Journal of Current Engineering and Technology E-ISSN 2277 4106, P-ISSN 2347 5161 2016 INPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijcet Review Article Review

More information

White Paper. Executive Summary. Overview of Membrane Exchangers CLCH-PRB063A-EN. June 2017

White Paper. Executive Summary. Overview of Membrane Exchangers CLCH-PRB063A-EN. June 2017 White Paper Overview of Membrane Exchangers Executive Summary Membrane exchangers, also called enthalpy cores, are used to recover sensible and latent energy between exhaust air and outside air. The most

More information

Liquid Desiccant Air Conditioning Systems

Liquid Desiccant Air Conditioning Systems Liquid Desiccant Air Conditioning Systems High-Efficiency Industrial Dehumidification High-Efficiency External Air Dehumidification Energy-Efficient Heat Pump Drying For Industries Use Only www.ascsciences.com

More information

On the cover Integrated professional services designed for your unique business need.

On the cover Integrated professional services designed for your unique business need. FAN COIL UNITS YGFC On the cover Integrated professional services designed for your unique business need. We care about your business and understand that each business has its unique requirements.our all-encompassing

More information

Easdale International INFINITY

Easdale International INFINITY Easdale International INFINITY Air flow from 800 to 0.000 m 3 /h APPLIED SYSTEM AIR HANDLING UNITS AHU N : 0.0.502 Range: Easdale International www.eurovent-certification.com www.certiflash.com Engineered

More information

Catalogue 2015 AMITIME ELECTRIC CO., LTD Add: Yandong 5th Rd, Dayan Industrial Zone, Huangpu Town, Zhongshan City, Guangdong, China Tel: 86-760-23973810 Fax: 86-760-23973813 Email: info@amitime.com Http://www.amitime.com

More information

TopMaster Air Handling unit. Technical data

TopMaster Air Handling unit. Technical data Technical data Contents Page Description of the unit... 3 Design... 4 Technical data Size 030... 5 Size 0... 6 Accessories... 7 Controls... 9 Control functions... 10 Order codes... 11 Fläkt Woods 8180

More information

The ultimate in air handling units: directly and indirectly fired

The ultimate in air handling units: directly and indirectly fired KLIMAT The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake

More information

WHHR Midi & Midi Lite

WHHR Midi & Midi Lite WHHR Midi & Midi Lite Residential Whole House Heat Recovery Units with Low Energy EC Motors Optional - Integral LCD Installation, Operating and Maintenance Instructions Image of model with LCD screen Page

More information

Heat Recovery Unit (Aluminium Plate) Energy Recovery Unit (Rotary)

Heat Recovery Unit (Aluminium Plate) Energy Recovery Unit (Rotary) Heat Recovery Unit (Aluminium Plate) Energy Recovery Unit (Rotary) Clima Industries Index EROVENT Rotary Heat Recovery - Components - Performance Data - Rotary Heat Exchanger - Configuration - Dimensions

More information

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC AQB8J6WC_IM_E_25864 2006.4.4 3:29 PM Page 7 INSTALLATION MANUAL Indoor Unit AQB8J6WC AQB24J2WC Outdoor Unit UQB8J6WC UQB24J2WC ENGLISH FRANÇAIS ESPAÑOL Split-type Air Conditioner (Cooling and Heating)

More information

Pharmaceutical Facility Design

Pharmaceutical Facility Design PhEn-602 Pharmaceutical Facility Design J. Manfredi Notes 9A PhEn-602 J. Manfredi 1 Primary & Secondary HVAC units Primary Primary air handling unit arrangement: One unit is responsible for all of the

More information

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB R407C EASY_R Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans 5,2 41,5 kw T_ESY_R_0508_GB EASY_R R407C INDEX WORKING LIMITS... 3 SERIES IDENTIFICATION... 4 MODEL

More information

VERSO Air Handling Units

VERSO Air Handling Units VERSO Air Handling Units Energy efficient solutions for profitable indoor climate VERSO Air Handling Units VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P

More information

Heat Recovery Ventilator Model PVe Light Industrial Commercial Institutional

Heat Recovery Ventilator Model PVe Light Industrial Commercial Institutional Heat Recovery Ventilator Model PVe Light Industrial Commercial Institutional 1,000-6,000 cfm 2.0 in. wg External Static Pressure Aluminum Plate Heat Exchanger April 2017 Heat Recovery Ventilators Greenheck

More information

Integrated VarIable refrigerant flow ahu/pau (r410a)

Integrated VarIable refrigerant flow ahu/pau (r410a) Integrated Variable Refrigerant Flow AHU/PAU (R410A) CONTENTS Features of VRF AHU/PAU 2 WELAIRE i-gt Concept 9 VRF Outdoor Unit Performance Data 10 Drawings & Performance Data 12 Dimensions 13 Notes 14

More information

Resolair 62 and 66. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 1,200 4,300 m³/h

Resolair 62 and 66. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 1,200 4,300 m³/h Comfort air conditioning unit with highly efficient regenerative heat storage packages 62 26 01 - simplified illustration Automatically selects the most economical operating mode! 62 and 66 AIR OLUME FLOW:

More information

ReCooler Heat-Pump Energy efficient cooling unit for eq Air Handling Unit

ReCooler Heat-Pump Energy efficient cooling unit for eq Air Handling Unit ReCooler Heat-Pump Energy efficient cooling unit for eq Air Handling Unit 28 May 2013 Agenda Introduction to Fläkt Woods Our Product Solution Technical Features Benefits Fläkt Woods Index We save energy!

More information

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S USER S MANUAL Heat (Energy) Recovery Ventilator Vents Frigate HRV 120 S Vents Frigate ERV 120 S 2 Frigate HRV(ERV) 120 S CONTENT Introduction... 3 Application... 3 Delivery set... 3 Unit designation key...

More information

DOMEKT ReGO 400VE(W)-B Series Air Handling Units Installation and Maintenance Service Manual

DOMEKT ReGO 400VE(W)-B Series Air Handling Units Installation and Maintenance Service Manual DOMEKT ReGO 400VE(W)-B Series Air Handling Units EN Content Safety Requirements...3 Transportation...3 Brief Description of the Unit...5 Installation...6 Maintenance...11 Technical Information......13

More information

Duct Type Fan Coil Unit. Air flow: 680~4590m 3 /h Cooling capacity: 3.7~22.6kW

Duct Type Fan Coil Unit. Air flow: 680~4590m 3 /h Cooling capacity: 3.7~22.6kW Duct Type Fan Coil Unit Air flow: 680~4590m 3 /h Cooling capacity: 3.7~.6kW Duct Type Fan Coil Unit Duct Type Fan Coil Unit Air flow: 680~4590m 3 /h Cooling capacity: 3.7~.6kW Cabinet and concealed duct

More information

FUJITSU VRF 2016/17 PRODUCT CATALOGUE VRF MULTI SPLIT VRF VENTILATION

FUJITSU VRF 2016/17 PRODUCT CATALOGUE VRF MULTI SPLIT VRF VENTILATION FUJITSU VRF PRODUCT CATALOGUE 2016/17 VRF VENTILATION SPLIT MULTI SPLIT VRF VENTILATION SUPPORT Design Simulator Automatically create model selection information Each unit can be automatically set by entering

More information

The plug & play fresh Air Solution

The plug & play fresh Air Solution Daikin Modular ADT range The plug & play fresh Air Solution A preselected installation package for air handling and outdoor units Easy ordering of AHU + DX package The need for clean and fresh air The

More information