1 CATALOGUE Setting a new standard for energy efficient, clean air homes Manufacturer reserves the right to change specifications without notice.

2 About Lifebreath For over 25 years Airia Brands Inc. has manufactured indoor air quality products to a worldwide customer base. Product development, research, testing, manufacturing, marketing, sales and technical support are headquartered at our 65,000 square foot facility in London, Ontario, Canada. We are recognized worldwide for the quality and performance of our Lifebreath product line, our customer service and our technical support. We will continue to lead the industry with technical innovations in our products, the highest level of customer support, superior warranties, and proven proficiency in manufacturing. Products We hold seven U.S. patents including some of the most important and leading edge technologies in the industry, including: heat recovery ventilator, air to air exchanger core (HRV core), combined furnace and heat recovery system, and more. Many more patents are pending. Our eco-friendly and energy efficient solutions include ECM motors in many models and standard state-of-the-art digital controls that allow customers to personalize HRV operation for their environment. We proudly manufacture the only five speed HRV available, with an included wall control. Our patented aluminum HRV core carries a lifetime guarantee and is easily maintained. Just wash and return. Our new ERV non-cellulose core will not deteriorate with moisture and is the only water-washable ERV core available today. Everything in our line is designed for superior performance and low maintenance to ensure complete installer and customer satisfaction. Energy Star A new ENERGY STAR specification was introduced to the Canadian residential energy and heat recovery ventilator (ERV/HRV) industry beginning January Airia Brands Inc., proud manufacturers of Lifebreath products are an active participant of this prominent program. The ENERGY STAR symbol identifies products that meet or exceed stringent energy efficiency criteria achieving uncompromised performance. Our commitment to high performance and energy efficiency has always been of paramount importance to Airia Brands, and most Lifebreath residential products qualify for this important energy efficiency benchmark. ENERGY STAR products may qualify for energy efficiency rebates. Incentive programs vary by geography and date. Check industry programs in your area for qualifying incentives. Look For This Symbol This product earned the ENERGY STAR by meeting strict energy efficiency guidelines set by Natural Resources Canada and the US EPA. This meets ENERGY STAR requirements only when used in Canada. Certified Lifebreath HRV products include: RNC5-TPD, RNC 95, RNC 200, 95 MAX, 155 ECM, 195 ECM, 200 MAX, 200 MAX RX, 195 DCS and 300 DCS. See Ventilation section, pages 3-16 for more details.

3 INDEX NEW FROM AIRIA VENTILATION HRV - Residential - MAX Series HRV - Residential - RNC Series ERV Series Commercial Series Pool Series AIR CLEANING TFP 3000 HEPA HEATING / AIR HANDLING Clean Air Furnace Series Air Handler Series IVS INLINE FANS Quantum Ventilation Series Bathroom and Dryer Exhaust Series LIFEBREATH ACCESSORIES Ventilation Accessories EasyAir Grilles and Fittings Installation and Replacement Controls and Timers PRODUCT SELECTION GUIDELINES TERMS AND CONDITIONS For additional information about Lifebreath products in this catalogue, downloads and much more, visit us at 1

4 NEW FROM AIRIA RNC5-TPD Now with Door Port Balancing Unique Installer Selectable High Speed Setting, accommodates multiple ventilation rates Smaller footprint saves space in utility room, while still containing a full size heat recovery core Ideally suited for narrow installations Top ports add to ease of installation HVI and ENERGY STAR certified NEWDual Hood Saves installation time and money Requires only one 6 inch opening in exterior wall to complete connections for intake/exhaust Highly robust design, with damage-resistant metal construction through exterior wall Suitable for 5 or 6 inch connections NEW Hanging Strap System EasyAir Grilles and Fittings Complete line of accessories that complement the installation of all Lifebreath ventilation products Now included with every Lifebreath Residential HRV product* (*except RNC120D) Four heavy duty straps and S-hooks included Easy mount system enables pre-assembly on floor Leveling procedure greatly simplified with adjustable clip 2

5 HR Residentia V l Dimensions: Inches (mm) Dimensions: Inches (mm) 3

6 HR V Residenti al Dimensions: Inches (mm) Dimensions: Inches (mm) 4

7 HR V Residenti al HR V MAX SERIES HEAT RECOVERY VENTILATORS 95 MAX 155 MAX / 155 MAX RX *Sensible Efficiency: thermal *Sensible Efficiency: thermal Weight: 52lbs (23.6Kg) Dimensions: Inches (mm) Weight: 71lbs (32.5Kg) Dimensions: Inches (mm) The RX version of this model is reverse flow. The cold side ducting to the weatherhoods and damper are located on the opposite side of the unit. 6

8 HR V Residenti al HR V MAX SERIES HEAT RECOVERY VENTILATORS 95 MAX 155 MAX / 155 MAX RX *Sensible Efficiency: thermal *Sensible Efficiency: thermal Weight: 52lbs (23.6Kg) Dimensions: Inches (mm) Weight: 71lbs (32.5Kg) Dimensions: Inches (mm) The RX version of this model is reverse flow. The cold side ducting to the weatherhoods and damper are located on the opposite side of the unit. 6

9 HR Residentia V l MAX SERIES HEAT RECOVERY VENTILATORS 155 ECM 195 ECM *Sensible Efficiency: thermal Effectiveness based on temperature differential between the 2 airstreams. Efficiency takes into account all power inputs. *Sensible Efficiency: thermal Effectiveness based on temperature differential between the 2 airstreams. Efficiency takes into account all power inputs High Speed 4 - Medium High Speed 3 - Medium Speed 2 - Medium Low Speed 1 - Low speed Weight: 71lbs (32.5Kg) Dimensions: Inches (mm) Weight: 88lbs (40Kg) Dimensions: Inches (mm) 7

10 HR V Residenti al MAX SERIES HEAT RECOVERY VENTILATORS 200 MAX / 200 MAX RX 195 DCS *Sensible Efficiency: thermal Effectiveness based on temperature differential between the 2 airstreams. Efficiency takes into account all power inputs. *Sensible Efficiency: thermal Effectiveness based on temperature differential between the 2 airstreams. Efficiency takes into account all power inputs. Weight: 71lbs (32.5Kg) Dimensions: Inches (mm) Weight: 88lbs (40Kg) Dimensions: Inches (mm) The RX version of this model is reverse flow. The cold side ducting to the weatherhoods and damper are located on the opposite side of the unit. 8

11 HR Residentia V l MAX SERIES HEAT RECOVERY VENTILATORS 300 DCS *Sensible Efficiency: thermal Effectiveness based on temperature differential between the 2 airstreams. Efficiency takes into account all power inputs. Weight: 89lbs (40.5Kg) Dimensions: Inches (mm) 9

12

13 11 HR Residentia V l

14 HR V Residenti al 12

15 HR Residentia V l RNC SERIES HEAT RECOVERY VENTILATORS Engineering Data THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE The cross-flow heat recovery core transfers heat between the two airstreams. It is easily removed for cleaning or service. MOTORS AND BLOWERS Each air stream has one centrifugal blower driven by a common PSC motor. 2-speed fan operation. RNC5-TPD and RNC 120 have two motors; one in each airstream. RNC5-TPD has three selectable high speeds FILTERS Washable air filters in exhaust and supply air streams. MOUNTING Four threaded inserts at corners of the cabinet designed to accept the s hooks and hanging straps supplied with the unit. DEFROST - 2 Styles Recirculating defrost system or damper defrost. CASE Twenty gauge prepainted galvanized steel for superior corrosion resistance. Insulated to prevent exterior condensation. Drain connections 2-1/2" (12 mm) OD. CONTROLS & ELECTRONICS Built-in Relay for Interfacing to furnace A standard ON/OFF switch can be added to provide Low/High Ventilation or ON/OFF functionality in order to meet building standards. Optional controls can be installed at the time of the installation or at a later date to upgrade the basic features of the ventilation system. RNC 95 *Sensible Efficiency: thermal OPTIONAL EQUIPMENT CONTROLS 99-DX01 Lifestyle RNC Digital Control 2-Speed operation on each mode 4 user selectable operational modes: Continuous Ventilation, 20 ON/40 OFF, 20 ON/40 Recirculation, Continuous Recirculation Adjustable Dehumidistat function built into the main wall control Connect to (3 wire) 20 gauge wire (min.) 100 length. 99-BC01 Lifestyle RNC Ventilation Control 2-Speed Fan setting (Low/High) Standby Dehumidistat Connect to (3 wire) 20 gauge wire (min.) 100 length. TIMERS 99-DET01 Lifestyle 20/40/60 Minute Timer - Initiates high speed ventilation for 20, 40, or 60 minutes, (3 wire) 20 gauge wire (min.) 100 length M01 Lifestyle 20 Minute Timer - Initiates high speed ventilation for 20 minutes, (3 wire) 20 gauge wire (min.) 100 length. ACCESSORIES 99-DH-01 Lifestyle Dehumidistat - Initiates high speed ventilation when the indoor humidity level is above the set point. (3 wire) 20 gauge wire (min.) 100 length Dual Hood - Suitable for 5 or 6 connections Weatherhoods - Two - 5 (125 mm) c/w 1/4 (6 mm) mesh screen Weatherhoods - Two - 6 (150 mm) c/w 1/4 (6mm) mesh screen. Many more accessory options available. See Accessories section for details. Weight: 52lbs (23.6Kg) Dimensions: Inches (mm) Units carry a LIFETIME warranty on the heat recovery core and a 5 year replacement parts warranty. All units conform to CSA and UL Standards. 13

16 HR V Residenti al RNC SERIES HEAT RECOVERY VENTILATORS RNC5-TPD RNC 120D *Sensible Efficiency: thermal Effectiveness based on temperature differential between the 2 airstreams. Efficiency takes into account all power inputs. *Sensible Efficiency: thermal Effectiveness based on temperature differential between the 2 airstreams. Efficiency takes into account all power inputs. HI 3 HI 3 - High Speed HI 2 - Medium High HI 1 - Medium Low HI 2 HI 1 LOW Weight: 61lbs (28Kg) Dimensions: Inches (mm) Weight: 61lbs (28Kg) Dimensions: Inches (mm) 14

17 HR Residentia V l RNC SERIES HEAT RECOVERY VENTILATORS RNC 155 RNC 200 *Sensible Efficiency: thermal Effectiveness based on temperature differential between the 2 airstreams. Efficiency takes into account all power inputs. *Sensible Efficiency: thermal Effectiveness based on temperature differential between the 2 airstreams. Efficiency takes into account all power inputs. Weight: 71lbs (32.5Kg) Dimensions: Inches (mm) Weight: 71lbs (32.5Kg) Dimensions: Inches (mm) 15

18 HR V Residenti al RNC SERIES HEAT RECOVERY VENTILATORS RNC 10 RNC 20 *Sensible Efficiency: thermal Effectiveness based on temperature differential between the 2 airstreams. Efficiency takes into account all power inputs. *Sensible Efficiency: thermal Effectiveness based on temperature differential between the 2 airstreams. Efficiency takes into account all power inputs. Weight: 63lbs (28.7Kg) Dimensions: Inches (mm) Weight: 63lbs (28.7Kg) Dimensions: Inches (mm) 16

19 17 ER Resid. V / Comm.

20 ER V Resid. / Comm. 18

21 ER Resid. V / Comm. ERV SERIES ENERGY RECOVERY VENTILATORS Engineering Data CORES 120/150/200 ERV: The crossflow energy recovery core transfers heat and vapour. 500 ERV: Modular (4 section) 2-Enthalpic, 2 Aluminum arranged for high efficiency crossflow ventilation. 700 ERV: Modular (2 section) enthalpic (moisture) transfer cores arranged for efficient crossflow ventilation 1200 ERV: Modular (3 section) latent recovery (moisture) transfer cores arranged for efficient crossflow ventilation. MOTORS 120 ERV: Each air stream has one PSC motor, 5 speed. 150/200 ERV: Each air stream has one centrifugal blower driven by a common PSC motor, 5 speed fan operation. High speed 120 VAC. 500 ERV: Two PSC, 5 speed double shafted 120 VAC, 3.15 Amps each (6.3 total on high speed). HP 1/10, 1625RPM. Watts total on high speed ERV: Two PSC, 3 speed single shafted, 120 VAC, 2.75 Amps each (5.5 total on high speed). HP 1/10, 1625RPM. Watts total on high speed ERV: Two PSC, 3 speed double shafted, 120 VAC, 4 Amps each (8.1 total on high speed). HP 1/2, 1625RPM. Watts total on high speed 972. BLOWERS 120/150/200 ERV: Each air stream has one centrifugal blower. 500 ERV: Centrifugal type, rated at 530 cfm (250 L/s) free air delivery. Each air stream has two centrifugal blowers driven by two PSC motors. 700 ERV: Centrifugal type, rated at 700 cfm (329 L/s) free air delivery. Each air stream has one single shafted motor driving a centrifugal blower ERV: Centrifugal type, rated at 1200 cfm (566 L/s) free air delivery. Each air stream has one double shafted motor driving a centrifugal blower. FILTERS Washable air filters in exhaust and supply air streams. CONNECTION DUCT SIZES 120 ERV: 5 (127mm) 150/200 ERV: 6 (150mm) 500 ERV: Four 14 x 8 (356mm x 200mm) 700 ERV: Four 14 x 8 (356mm x 200mm) 1200 ERV: Four 20 x 8 (508mm x 200mm). MOUNTING - NEW! 120/150/200 ERV: Four threaded inserts at corners of the cabinet designed to accept the s hooks and hanging straps supplied with the unit. 500 / 700 / 1200 ERV: Unit to be set on support brackets hung by threaded rod type apparatus (brackets and rods not included). CASE Twenty gauge prepainted galvanized steel for superior corrosion resistance. Insulated with foil faced insulation where required to prevent exterior condensation. CONTROLS & ELECTRONICS 99-DXPL01 (included on 150/200/500 ERV units) Lifestyle Digital Control Can be wall mounted in a central location of the home. Connects to (3 wire) 20 gauge wire (min.) 100 length. Electronic features include: 5 Speed Operation on each mode 2 user selectable operational modes: Continuous Ventilation, 20 ON/40 OFF Humidity Control through dehumidistat Adjustable Dehumidistat function built into the main wall control Built-in Relay for interfacing to furnace OPTIONAL EQUIPMENT CONTROLS 99-LS01 Lifestyle Programmable Control Contains all the features of the Lifestyle Digital Control with 7/24 programmable ventilation, 4 event feature permits lifestyle programming. Connects to (3 wire) 20 gauge wire (min.) 100 length. Units carry a five year warranty on the energy recovery core and a 5 year replacement parts warranty. All units conform to CSA and UL Standards. 19

22 ER V Resid. / Comm. ERV SERIES ENERGY RECOVERY VENTILATORS 120 ERV 150 ERV *Sensible Efficiency: thermal **Latent Efficiency: moisture *Sensible Efficiency: thermal **Latent Efficiency: moisture Effectiveness based on temperature differential between the 2 airstreams. Efficiency takes into account all power inputs. Effectiveness based on temperature differential between the 2 airstreams. Efficiency takes into account all power inputs. Dimensions: Inches (mm) Weight: 63lbs (28.7Kg) Dimensions: Inches (mm) 20

23 ER Resid. V / Comm. ERV SERIES ENERGY RECOVERY VENTILATORS 200 ERV 500 ERV *Sensible Efficiency: thermal **Latent Efficiency: moisture Effectiveness based on temperature differential between the 2 airstreams. Efficiency takes into account all power inputs. Weight: 178lbs (81Kg) Dimensions: Inches (mm) Weight: 63lbs (28.7Kg) Dimensions: Inches (mm) 21

24 ER V Resid. / Comm. ERV SERIES ENERGY RECOVERY VENTILATORS 700 ERV 1200 ERV Weight: 178lbs (81Kg) Dimensions: Inches (mm) Weight: 191lbs (87Kg) Dimensions: Inches (mm) 22

25 23 HR Commercia V l

26 HR V Commerci al 24

27 HR Commercia V l COMMERCIAL HEAT RECOVERY VENTILATORS Engineering Data CORES Modular (4 section) patented aluminum heat recovery cores arranged for efficient cross-flow ventilation. MOTORS Two PSC, 5 speed double shafted, 120 VAC, 3.1 Amps each (6.2 total on high speed). HP 1/3, 1620 RPM. Watts total on high speed 610. FILTERS Washable air filters in exhaust and supply air streams. BLOWERS Centrifugal type rated at 530 cfm (250 L/s) free air delivery. Each air stream has two centrifugal blowers driven by two PSC motors. CONNECTION DUCT SIZES Four 14 x 8 (356mm x 200mm) MOUNTING Unit to be set on support brackets hung by threaded rod type apparatus (brackets and rods not included). CASE 20 gauge pre-painted galvanized steel for superior corrosion resistance. Insulated with foil faced insulation duct liner where required to prevent exterior condensation. Drain connection, One 1/2 (12mm) O.D. DEFROST Supply bypass damper routes indoor air to defrost cores. CONTROLS & ELECTRONICS The Lifestyle MAX Digital Control (99-DXPL01 included) can be wall mounted in a central location. Connects to (3 wire) 20 gauge wire (min.) 100 length. Features include: 5 speed operation on each mode 2 user selectable operational modes: Continuous ventilation, 20 ON / 40 OFF Humidity Control through dehumidistat Adjust. Dehumidistat function built into main wall control Built-in relay for interfacing to furnace OPTIONS 99-DETO1 Digital Electronic Timer 20/40/60 min 99-LS01 Lifestyle MAX Programmable Control 500 DCS / 500 DCS-REV Weight: 178lbs (81Kg) Dimensions: Inches (mm) (500 DCS-REV Shown) 2 year limited. 15 year HRV Core, 5 year ERV Core. All units conform to CSA and UL Standards. 25

28 HR V Commerci al COMMERCIAL HEAT RECOVERY VENTILATORS Engineering Data CORES Modular (6 section) patented aluminum heat recovery cores arranged for efficient cross-flow ventilation. MOTORS Two PSC, 3 speed double shafted, 120 VAC, 3.95 Amps each (7.9 total on high speed). HP 1/4, 1625 RPM. Watts total on high speed 848. FILTERS Washable air filters in exhaust and supply air streams. BLOWERS Centrifugal type rated at 950 cfm (448 L/s) free air delivery. Each air stream has one double shafted motor driving a centrifugal blower. CONNECTION DUCT SIZES Three 20 x 8 (508mm x 200mm). Stale air intake 26 x 8 (660mm x 200mm). Model 850DD additional 20 x 8 defrost port. MOUNTING Unit to be set on support brackets hung by threaded rod type apparatus (brackets and rods not included). CASE 20 gauge pre-painted galvanized steel for superior corrosion resistance. Insulated with foil faced insulation duct liner where required to prevent exterior condensation. Drain connections, two 1/2 (12mm) O.D. DEFROST 850 FD: Interrupts supply air while exhaust air defrosts core. 850 DD: Supply bypass routes indoor air to defrost core. CONTROLS & ELECTRONICS Integrated microprocessor circuit board. Built-in interlock contacts. Automatic Self Test. Optional remote speed control. OPTIONS New 99-DETO1 Digital Electronic Timer 20/40/60 min 99-BC01 Lifestyle RNC Ventilation Control 99-DH01 Remote Wallmount Dehumidistat Control Speed Control 850 FD / 850 DD Weight: 255lbs (116Kg) Dimensions: Inches (mm) 2 year limited. 15 year HRV Core, 5 year ERV Core. 26 All units conform to CSA and UL Standards.

29 HR Commercia V l COMMERCIAL HEAT RECOVERY VENTILATORS Engineering Data CORES Modular (2 section) patented aluminum heat recovery cores arranged for efficient cross-flow ventilation. MOTORS Two PSC, 3 speed single shafted, 120 VAC, 2.8 Amps each (5.6 total on high speed). HP 1/5, 1625 RPM. Watts total on high speed 648. FILTERS Washable air filters in exhaust and supply air streams. BLOWERS Centrifugal type rated at 700 cfm (329 L/s) free air delivery. Each air stream has one single shafted motor driving a centrifugal blower. CONNECTION DUCT SIZES Four 14 x 8 (356mm x 200mm) MOUNTING Unit to be set on support brackets hung by threaded rod type apparatus (brackets and rods not included). CASE 20 gauge pre-painted galvanized steel for superior corrosion resistance. Insulated with foil faced insulation duct liner where required to prevent exterior condensation. Drain connections, two 1/2 (12mm) O.D. DEFROST 700 FD: Interrupts supply air while exhaust air defrosts core. 700 DD: Supply bypass routes indoor air to defrost core. CONTROLS & ELECTRONICS Integrated microprocessor circuit board. Built-in interlock contacts. Automatic Self Test. Optional remote speed control. OPTIONS 99-DETO1 Digital Electronic Timer 20/40/60 min 99-BC01 Lifestyle RNC Ventilation Control 99-DH01 Remote Wallmount Dehumidistat Control Speed Control 700 FD / 700 DD Weight: 155lbs (70Kg) Dimensions: Inches (mm) 2 year limited. 15 year HRV Core, 5 year ERV Core. All units conform to CSA and UL Standards. 27

30 HR V Commerci al COMMERCIAL HEAT RECOVERY VENTILATORS Engineering Data CORES Modular (2 section) patented aluminum heat recovery cores arranged for efficient cross-flow ventilation. MOTORS Two PSC, 3 speed single shafted, 120 VAC, 4.5 Amps each (9 total on high speed). HP 1/4, 1450 RPM. Watts total on high speed FILTERS Washable air filters in exhaust and supply air streams. BLOWERS Centrifugal type rated at 700 cfm (329 in w.c. Each air stream has one single shafted motor driving a centrifugal blower. CONNECTION DUCT SIZES Four 14 x 8 (356mm x 200mm) MOUNTING Unit to be set on support brackets hung by threaded rod type apparatus (brackets and rods not included). CASE 20 gauge pre-painted galvanized steel for superior corrosion resistance. Insulated with foil faced insulation duct liner where required to prevent exterior condensation. Drain connections, two 1/2 (12mm) O.D. DEFROST 700 FD PLUS: Interrupts supply air while exhaust air defrosts core. 700 DD PLUS: Supply bypass routes indoor air to defrost core. CONTROLS & ELECTRONICS Integrated microprocessor circuit board. Built-in interlock contacts. Automatic Self Test. Optional remote speed control. OPTIONS 99-DETO1 Digital Electronic Timer 20/40/60 min 99-BC01 Lifestyle RNC Ventilation Control 99-DH01 Remote Wallmount Dehumidistat Control Speed Control 700 FD PLUS / 700 DD PLUS Weight: 155lbs (70Kg) Dimensions: Inches (mm) 2 year limited. 15 year HRV Core, 5 year ERV Core. 28 All units conform to CSA and UL Standards.

31 HR Commercia V l COMMERCIAL HEAT RECOVERY VENTILATORS Engineering Data CORES Modular (3 section) patented aluminum heat recovery cores arranged for efficient cross-flow ventilation. MOTORS Two PSC, 3 speed double shafted, 120 VAC, 4 Amps each (8.1 total on high speed). HP 1/4, 1625 RPM. Watts total on high speed FD / 1200 DD FILTERS Washable air filters in exhaust and supply air streams. BLOWERS Centrifugal type rated at 1200 cfm (566 in w.c. Each air stream has one double shafted motor driving a centrifugal blower. CONNECTION DUCT SIZES Four 20 x 8 (508mm x 200mm) MOUNTING Unit to be set on support brackets hung by threaded rod type apparatus (brackets and rods not included). CASE 20 gauge pre-painted galvanized steel for superior corrosion resistance. Insulated with foil faced insulation duct liner where required to prevent exterior condensation. Drain connections, two 1/2 (12mm) O.D. DEFROST 1200 FD: Interupts supply air while exhaust air defrosts core 1200 DD: Supply bypass routes indoor air to defrost core. CONTROLS & ELECTRONICS Integrated microprocessor circuit board. Built-in interlock contacts. Automatic Self Test. Optional remote speed control. OPTIONS 99-DETO1 Digital Electronic Timer 20/40/60 min 99-BC01 Lifestyle RNC Ventilation Control 99-DH01 Remote Wallmount Dehumidistat Control Speed Control Weight: 191lbs (87Kg) Dimensions: Inches (mm) 2 year limited. 15 year HRV Core, 5 year ERV Core. All units conform to CSA and UL Standards. 29

32 HR V Commerci al COMMERCIAL HEAT RECOVERY VENTILATORS Engineering Data CORES Modular (3 section) patented aluminum heat recovery cores arranged for efficient cross-flow ventilation. MOTORS Two PSC, 3 speed double shafted, 120 VAC, 9.4 Amps each (18.8 total on high speed). HP 1/2, 1625 RPM. Watts total on high speed FILTERS Washable air filters in exhaust and supply air streams. BLOWERS Centrifugal type rated at 1200 cfm (566 in w.c. Each air stream has one double shafted motor driving a centrifugal blower. CONNECTION DUCT SIZES Four 20 x 8 (508mm x 200mm) MOUNTING Unit to be set on support brackets hung by threaded rod type apparatus (brackets and rods not included). CASE 20 gauge pre-painted galvanized steel for superior corrosion resistance. Insulated with foil faced insulation duct liner where required to prevent exterior condensation. Drain connections, two 1/2 (12mm) O.D. DEFROST 1200 FD PLUS: Interrupts supply air while exhaust air defrosts core DD PLUS: Supply bypass routes indoor air to defrost core. CONTROLS & ELECTRONICS Integrated microprocessor circuit board. Built-in interlock contacts. Automatic Self Test. Optional remote speed control. OPTIONS 99-DETO1 Digital Electronic Timer 20/40/60 min 99-BC01 Lifestyle RNC Ventilation Control 99-DH01 Remote Wallmount Dehumidistat Control Speed Control 1200 FD PLUS / 1200 DD PLUS Weight: 191lbs (87Kg) Dimensions: Inches (mm) 2 year limited. 15 year HRV Core, 5 year ERV Core. 30 All units conform to CSA and UL Standards.

33 HR Commercia V l COMMERCIAL HEAT RECOVERY VENTILATORS Engineering Data 1500 IFD / 1500 EFD AIRFLOW 1500 cfm (705 L/s) at 1.0 wg ESP. PERFORMANCE 65% effective at 1500 cfm (705 L/s). CORES Six patented aluminum heat recovery cores arranged for efficient cross-flow ventilation. MOTORS Two single shaft ECM variable speed, 208/240V, 9.1 Amps, 1 ph, 1 hp, (18.2 amps total). BLOWERS Two direct drive centrifugal blowers, one per airstream. FILTERS Two 20 x 16 x 2 (508mm x 406mm x 50 mm) pleated filters in each airstream. MERV 6. CONNECTION DUCT SIZES 1500 IFD: Four 18 x 18 (457mm x 457mm) EFD: Two 19 x 16 (482mm x 406mm) to and from building, under cabinet. Two 18 x 17 (457mm x 431mm) hoods included on side of cabinet, with washable screens. CABINET 20 gauge powder-coated galvanized steel 1 (25mm) thick. Elastomeric insulation. DEFROST Factory set defrost time. Supply motor is shut off while exhaust air defrosts core. DRAIN Two powder coated steel drain pans with 1/2 (12mm) O.D. drain connections. MOUNTING Rooftop mounted on optional roof curb. (Part No ) CONTROLS & FUNCTION Integrated microprocessor circuit board. Three independently adjustable motor speeds. OPTIONS 99-DETO1 Digital Electronic Timer 20/40/60 min 99-BC01 Lifestyle RNC Ventilation Control 99-DH01 Remote Wallmount Dehumidistat Control Speed Control 2 year limited. 15 year HRV Core, 5 year ERV Core. Engineering Data 2000 IFD / 2000 EFD AIRFLOW 2000 cfm (940 L/s) at 1.0 wg ESP. PERFORMANCE 65% effective at 2000 cfm (940 L/s). CORES Eight patented aluminum heat recovery cores arranged for efficient cross-flow ventilation. MOTORS Two PSC. 2 hp, 1 ph, single speed, single shaft, 208/240VAC, 9.0 Amps (18 total). Optional 460 V, 570 V, 3 phase BLOWERS Two belt drive centrifugal blowers with adjustable pulleys, one per airstream. FILTERS Two 16 x 25 x 2 (406mm x 635mm x 50 mm) pleated filters in each airstream. CONNECTION DUCT SIZES 2000 IFD: Four 18 x 22 (457mm x 558mm) EFD: Two 20 x 19 (508mm x 482mm) hoods included with washable screens. Two 25 x 16 (635mm x 406mm) connections to and from building, under cabinet. CABINET 20 gauge powder-coated galvanized steel exterior for superior corrosion resistance. Unit includes metal lined sides and roof panels with 2 fiberglass insulation (R8) between linings. DEFROST Factory set defrost time. Supply motor is shut off while exhaust air defrosts core. DRAIN Two powder coated galvanized steel drain pans with 1/2 (12mm) O.D. drain connections. MOUNTING 2000 IFD: Unit to be set on support brackets hung by threaded rod type apparatus (brackets / rods not included) EFD: Optional roof curb. Part No CONTROLS & FUNCTION Integrated microprocessor circuit board. OPTIONS 99-DETO1 Digital Electronic Timer 20/40/60 min 99-BC01 Lifestyle RNC Ventilation Control 99-DH01 Remote Wallmount Dehumidistat Control All units conform to CSA and UL Standards. 31

34 HR V Commerci al COMMERCIAL HEAT RECOVERY VENTILATORS 1500 IFD / 1500 EFD 2000 IFD / 2000 EFD Dimensions 1500 IFD: Weight: 480lbs (218Kg) Dimensions 2000 IFD: Weight: 750lbs (340Kg) Dimensions 1500 EFD: Weight: 480lbs (218Kg) Dimensions 2000 EFD: Weight: 750lbs (340Kg) 32

35 HR Commercia V l COMMERCIAL HEAT RECOVERY VENTILATORS Engineering Data AIRFLOW 2500 cfm (1175 L/s) at 1.0 wg ESP IFD PERFORMANCE 70% effective at 2500 cfm (1172 L/s). CORES Single aluminum sensible heat recovery core. Plate-toplate type. Slides out of either side of cabinet for service. MOTORS Two single shaft PSC, 208/230V, 5.1 Amps, 1hp, 1ph, 3 speed motor (2 speeds selectable) BLOWERS Two direct-drive centrifugal blowers, one per air stream. FILTERS Two 18 x 24 (457mm x 610mm) 4-inch pleated filters in each air stream. Weight: 700lbs (318Kg) Dimensions: Inches (mm) CONNECTION DUCT SIZES Four 24 x 16 (610mm x 406mm). CABINET 20 gauge powder-coated galvanized steel exterior for superior corrosion resistance. 16 gauge galvanized frame, insulated with 1 fiberglass insulation to prevent condensation. DEFROST Factory set defrost time. Supply motor is shut off while exhaust air defrosts core. Two defrost times available. DRAIN Two stainless steel drain pans with 1/2 (12mm) NPT drain spouts. MOUNTING Unit can be set on floor or support brackets hung by threaded rod type apparatus. Brackets and rods not included. CONTROLS & FUNCTION Integrated microprocessor circuit board, optional remote 2 speed control, built in interlock contacts. OPTIONS 99-DETO1 Digital Electronic Timer 20/40/60 min 99-BC01 Lifestyle RNC Ventilation Control 99-DH01 Remote Wallmount Dehumidistat Control Speed Control 2 year limited. 15 year HRV Core, 5 year ERV Core. All units conform to CSA and UL Standards. 33

36 HR V Commerci al COMMERCIAL HEAT RECOVERY VENTILATORS Engineering Data AIRFLOW 2500 cfm (1175 L/s) at 1.0 wg ESP. PERFORMANCE 70% effective at 2500 cfm (1172 L/s). CORES Single aluminum sensible heat recovery core. Plate-toplate type. Slides out of either side of cabinet for service. MOTORS Two single shaft PSC, 208/230V, 5.1 Amps, 1hp, 1ph, 3 speed motor (2 speeds selectable) BLOWERS Two direct-drive centrifugal blowers, one per air stream. FILTERS Two 18 x 24 (457mm x 610mm) 4-inch pleated filters in each air stream. CONNECTION DUCT SIZES Two - 24 x 16 (610mm x 406mm) to and from the building, under cabinet. Two 28 x 18 (711mm x 457mm) hoods, included on side of cabinet with screens. CABINET 20 gauge powder-coated galvanized steel exterior for superior corrosion resistance. 16 gauge galvanized frame, insulated with 1 fiberglass insulation to prevent condensation. DEFROST Factory set defrost time. Supply motor is shut off while exhaust air defrosts core. Two defrost times available. DRAIN Two stainless steel drain pans with 1/2 (12mm) NPT drain spouts. MOUNTING Rooftop mounted on optional roof curb. Part No CONTROLS & FUNCTION Integrated microprocessor circuit board, optional remote 2 speed control, built in interlock contacts. OPTIONS 99-DETO1 Digital Electronic Timer 20/40/60 min 99-BC01 Lifestyle RNC Ventilation Control 99-DH01 Remote Wallmount Dehumidistat Control Speed Control 2500 EFD Weight: 700lbs (318Kg) Dimensions: Inches (mm) 2 year limited. 15 year HRV Core, 5 year ERV Core. All units conform to CSA and UL Standards. 34

37 HR Poo V l COMMERCIAL-POOL HEAT RECOVERY VENTILATORS Engineering Data 700 POOL / 1200 POOL CORES Modular (2 section-model 700 / 3 section-model 1200) patented aluminum heat recovery cores arranged for efficient cross-flow ventilation. Meets the flame spread and smoke developed classifications of the National Building Code and NFPA 90A (1993 Edition). MOTORS 700 POOL: Two PSC, 3 speed single shafted, 120 VAC, 4.5 Amps each (9 total on high speed). HP - 1/4, 1450 RPM POOL: Two PSC, 3 speed double shafted, 120 VAC, 9.4 Amps each (18.8 total on high speed). HP - 1/2, 1625 RPM. FILTERS Washable air filters in exhaust and supply air streams. BLOWERS 700 POOL: Each air stream has one single shafted motor driving a centrifugal blower POOL: Each air stream has one double shafted motor driving 2 centrifugal blowers. CONNECTION DUCT SIZES 700 POOL: Five - 14" x 8" H (356 mm x 200 mm) POOL: Five - 20" x 8" H (305 mm x 200 mm). MOUNTING Unit to be set on brackets or suspended by threaded rod. (brackets and rod not provided). CASE Prepainted galvanized steel for superior corrosion resistance. Insulated with closed cell foam insulation where required to prevent exterior condensation. Drain connections; two - 1/2 (12 mm) O.D. CONTROLS & FUNCTION Integrated microprocessor circuit board. Built-in interlock contacts. Includes remote dehumidistat (Part# 99-DH01). Optional 20/40/60 Minute timer (Part# 99-DET01). DEFROST Supply bypass routes indoor air to defrost core. WEIGHT 700 POOL: Weight 155 lbs. (70 kg) POOL: Weight 210 lbs. (95 kg). All units carry a 15 year warranty on the heat recovery cores and a 2 year replacement parts warranty. All units conform to CSA and UL Standards. 35

38 HR V Po ol COMMERCIAL-POOL HEAT RECOVERY VENTILATORS 700 POOL 1200 POOL Weight: 155lbs (70Kg) Dimensions: Inches (mm) Weight: 210lbs (95Kg) Dimensions: Inches (mm) 36

39 TFP 3000 HEPA Air Cleaner Dimensions: Inches (mm) Dimensions: Inches (mm) 37

40 TFP 3000 HEPA Air Cleaner TFP 3000 HEPA A I R C L E A N E R Engineering Data MOTOR AND BLOWER 2 speed, high efficiency PSC Motor cfm/75 cfm. 110 watts VAC - standard three prong plug to receptacle. The TFP is equipped with a standard power cord 5 5 (1.6 meters) long. OFF/LOW/HIGH SPEED SELECTOR SWITCH Select 75 cfm (Low) or 150 cfm (High). AIRFLOW WC (High Speed) 75 WC (Low Speed) COLLECTORS One replaceable TFP collector and one replaceable HEPA filter Easy to remove for cleaning and replacement Annual inspection recommended CASE Twenty gauge prepainted galvanized steel for superior corrosion resistance WEIGHT 55 lbs. (24.4 Kgs) ELECTRICAL CODES Conforms to CSA and UL standards MOUNTING THE WHOLE HOME TFP - VERY FLEXIBLE Mount to the furnace return Mount between the HRV and the furnace Hang from a joist and duct to the furnace REPLACEMENT OPTIONS R - One replacement TFP collector R - One replacement HEPA filter Optional Installation Kit: Part # 99-TFP Includes: - Two 7 duct connection collars of 7 non-insulated flex duct - Four nylon duct zip ties TFP 3000 HEPA Dimensions: Inches (mm) Five year warranty on all replacement parts except the collectors/filters. Conforms to CSA and UL Standards. 38

41 39 CA Hydroni F c

42 CA F Hydron ic 40

43 41 CA Hydroni F c

44 CA F Hydron ic 42

45 CA Hydroni F c CLEAN AIR FURNACE HYDRONIC SERIES Model Number Nomenclature Breakdown CAF - Clean Air Furnace (Built-in HRV) Refer to AH (Air Handler) specifications if a built-in HRV is not required U - Upflow - Return Air off Left or Right side D - Downflow - Return air off Left side, Right side or Top (not available for L2A or 00 Coils) H - Horizontal - Return on Left side only (not available for L2A or 00 Coils) Available Clean Air Furnace Models CAF-U-S4A-24-P16(E16) CAF-D-S4A-24-P16(E16) CAF-H-S4A-24-P16(E16) CAF-U-L4A-36-P16(E16) CAF-D-L4A-36-P16(E16) CAF-H-L4A-36-P16(E16) CAF-U-L2A-48-P16(E16) CAF-U P16(E16) CAF-U P16(E16) CAF-U P16(E16) S4A - Small Coil - 4 Row Coil L2A - Large Coil - 2 Row Coil (available in upflow only) L4A - Large Coil - 4 Row Coil 00 - No Hydronics - No Heating Coil, No Pump (available in upflow only) * CFM (High Speed) Cooling Capacity Refer to individual specification pages for Hydronic Coil and Blower outputs and configurations. Units carry a lifetime warranty on the heat recovery (aluminum) core, a five year warranty on the energy recovery (enthalpic) core and a five year replacement parts warranty on all other components. All units conform to CSA and UL Standards. 43

46 CA F Hydron ic CLEAN AIR FURNACE HYDRONIC SERIES Coil Output (1000 s of BTUH) CAF-D-S4A-24-P16 / CAF-H-S4A-24-P16 / CAF-U-S4A-24-P16 Technical Specifications CAF-D-S4A-24-P16 CAF-H-S4A-24-P16 CAF-U-S4A-24-P16 Dimensions CAF-D-S4A-24-P16 CAF-H-S4A-24-P16 44 Engineering Data CORE Ventilation system has patented aluminum heat recovery core (standard) or an enthalpic energy recovery core (optional) for energy-efficient ventilation. Enthalpic cores are recommended for regions where temperature does not drop below 25F (-4C). FILTERS Washable air filters in exhaust and supply air streams of ventilation section. 1" (25mm) pleated in return plenum side. CASE Pre-painted galvanized steel for superior corrosion resistance. OPTIONS Weatherhoods, Two - 6" (150cm) c/w 1/4" (6mm) mesh screen 99-DH01 Remote wall mount dehumidistat control 99-RSK6 6" (150mm) Backdraft damper 99-DET01 Digital Electronic Timer CAF-U-S4A-24-P16

47 CA Hydroni F c CLEAN AIR FURNACE HYDRONIC SERIES Coil Output (1000 s of BTUH) CAF-D-L4A-36-P16 / CAF-H-L4A-36-P16 / CAF-U-L4A-36-P16 / CAF-U P16* Technical Specifications CAF-D-L4A-36-P16 CAF-H-L4A-36-P16 CAF-U-L4A-36-P16 CAF-U P16* Dimensions CAF-D-S4A-36-P16 CAF-H-S4A-36-P16 Engineering Data CORE Ventilation system has patented aluminum heat recovery core (standard) or an enthalpic energy recovery core (optional) for energy-efficient ventilation. Enthalpic cores are recommended for regions where temperature does not drop below 25F (-4C). FILTERS Washable air filters in exhaust and supply air streams of ventilation section. 1" (25mm) pleated in return plenum side. CASE Pre-painted galvanized steel for superior corrosion resistance. OPTIONS Weatherhoods, Two - 6" (150cm) c/w 1/4" (6mm) mesh screen 99-DH01 Remote wall mount dehumidistat control 99-RSK6 6" (150mm) Backdraft damper 99-DET01 Digital Electronic Timer CAF-U-S4A-36-P16 / CAF-U P16 45

48 CA F Hydron ic CLEAN AIR FURNACE HYDRONIC SERIES Coil Output (1000 s of BTUH) CAF-U-L2A-48-P16 / CAF-U P16 Technical Specifications Dimensions CAF-U-L2A-48-P16 CAF-U P16* CAF-U-L2A-48-P16 / CAF-U P16 Engineering Data CORE Ventilation system has patented aluminum heat recovery core (standard) or an enthalpic energy recovery core (optional) for energy-efficient ventilation. Enthalpic cores are recommended for regions where temperature does not drop below 25F (-4C). FILTERS Washable air filters in exhaust and supply air streams of ventilation section. 1" (25mm) pleated in return plenum side. CASE Pre-painted galvanized steel for superior corrosion resistance. OPTIONS Weatherhoods, Two - 6" (150cm) c/w 1/4" (6mm) mesh screen 99-DH01 Remote wall mount dehumidistat control 99-RSK6 6" (150mm) Backdraft damper 99-DET01 Digital Electronic Timer 46

49 47 Air Handler Serie s

50 Air Handler Serie s 48

51 Air Handler Serie s AIR HANDLER HYDRONIC SERIES Model Number Nomenclature Breakdown AH - Air Handler (No HRV) Refer to CAF (Clean Air Furnace) specifications if a built-in HRV is required U - Upflow - Return Air off Left or Right side D - Downflow models are unavailable for Air Handlers H - Horizontal models are unavailable for Air Handlers Available Air Handler Models AH-U-S2A-30-P16(E16) AH-U-S4A-24-P16(E16) AH-U-L2A-48-P16(E16) AH-U-L4A-36-P16(E16) AH-U-L2B-48-P16(E16) S2A - Small Coil - 2 Row Coil S4A - Small Coil - 4 Row Coil L2A - Large Coil - 2 Row Coil L4A - Large Coil - 4 Row Coil L2B - Large Coil - 2 Row Coil * CFM (High Speed) Cooling Capacity Refer to individual specification pages for Hydronic Coil and Blower outputs and configurations. Units carry a five year replacement parts warranty on all components. All units conform to CSA and UL Standards. 49

52 Air Handler Serie s AIR HANDLER HYDRONIC SERIES Coil Output (1000 s of BTUH) AH-U-S4A-24-P16 Coil Output (1000 s of BTUH) AH-U-S2A-30-P16 Technical Specifications AH-U-S4A-24-P16 Technical Specifications AH-U-S2A-30-P16 Dimensions AH-U-S4A-24-P16 / AH-U-S2A-30-P16 50

53 Air Handler Serie s AIR HANDLER HYDRONIC SERIES Coil Output (1000 s of BTUH) AH-U-L2A-36-P16 Coil Output (1000 s of BTUH) AH-U-L4A-36-P16 Technical Specifications AH-U-L2A-36-P16 Technical Specifications AH-U-L4A-36-P16 Dimensions AH-U-L2A-36-P16 / AH-U-L4A-36-P16 All units have an upflow configuration 51

54 Air Handler Serie s AIR HANDLER HYDRONIC SERIES Coil Output (1000 s of BTUH) AH-U-L2B-48-P16 Technical Specifications AH-U-L2B-48-P16 Dimensions AH-U-L2B-48-P16 All units have an upflow configuration 52

55 53 IV S

56 IV S 54

57 55 Inline Fans

58 Inline Fans 56

59 57 Inline Fans

60 Inline Fans 58

61 QVS Series QVS SERIES Quantum In-Line Fan Series All fans are commercial and residential certified; temperature rated -40 F to 140 F, 120 Volt/60Hz Model Airflow CFM (L/s) Part Number Features.2 (95 Pa) Number Description NBQ125-4 Multi-position metal bracket included 120 CFM 99-NBQ Dedicated Plastic NBQ-COMBI-4/5/6 Field selectable 4, 5 or 6 duct 180/ connection collars incl. 240/ Multi-position metal bracket included 270 CFM 99-NBQ-COMBI 4/5/6 Combi fan. Plastic 4 /5 /6. NBQ325-6 Multi-position metal bracket included 350 CFM 99-NBQ Dedicated Plastic NBQ pre-painted galvanized steel 440 CFM on Hi Multi-position metal bracket included 350 CFM on Low 99-NBQ Dedicated Plastic NBQ pre-painted galvanized steel 690 CFM on Hi 99-NBQ Mixed flow inline duct exhaust fan Multi-position metal bracket included 350 CFM on Low NBQ pre-painted galvanized steel 950 CFM on Hi 99-NBQ Mixed flow inline duct exhaust fan Multi-position metal bracket included 600 CFM on Low Fan Kits QVS KIT QVS KIT PLUS QVS KIT -001 Components Includes: NBQ-COMBI 4/5/6 fan, E-Box, 99-BC-01 (Ventilation Control), 2 x 99-DET01 (20/40/60 Minute Timers) and fan mounting bracket. Includes: NBQ-COMBI 4/5/6 fan, E-Box, 99-DX-01 (Digital Control), 2 x 99-DET01 (20/40/60 Minute Timers) and fan mounting bracket. Remote E-Box only, for QVS Kit Part Number 93-QVS KIT 93-QVS KIT PLUS 93-QVS KIT

62 Bathroom and Dryer Exhaust Series BATH AND DRYER EXHAUST SERIES Bathroom Exhaust Kits Bath Exhaust Kit Airflow CFM (L/s) Part Options Features.2 (95 Pa) Number Description Bath Exhaust Kit 4 4 Plastic Fan with mounting bracket, 4 Tech grille and 4 Damper/collar. 120 CFM 99-BEK-4 4 Plastic Fan Bath Exhaust Kit Combi COMBI 4/5/6 Fan with mounting bracket, (2) 6 Tech grilles, 2 (6 ) dampers. 180 CFM 270 CFM 99-BEK-COMBI Combi Fan Bath Exhaust System COMBI 4/5/6 Fan, BES Control Box, Fan Speed Selection 99-CAF-BESKIT For use with a Lifebreath Clean Air Furnace. (See illustration below) Dryer Exhaust Kits Dryer Exhaust Kit Airflow CFM (L/s) Part Options Features.2 (95 Pa) Number Description Dryer Booster Kit 4 4 Plastic Fan with mounting bracket, and Pressure Switch. 120 CFM 99-DBK-4-PRES 4 Plastic Fan Dryer Booster Kit COMBI Fan with mounting bracket, and 180 CFM CFM 99-DBK-COMBI Combi Fan Combi Current Switch. Current Switch Superior to different pressure switches 99-CSS Amps Max 60

63 ACCESSORIES Ventilation Accessories Features Part Number Description Dual Hood Requires only one 6 opening for intake/exhaust Robust design, with damage-resistant metal construction for exterior wall connection Durable rigid plastic for duct connections Fire-rated, UV resistant materials A breakthrough design. Requires only one 6 opening for intake/exhaust connections. Ideal for space constrained HRV or ERV applications Weatherhood High density polyethylene for long life even in severe climates Ideal for HRV, ERV and Inline apps. Kits Screens include to block entry by small animals, large Two 5 diameter hoods, 12 wall sleeve, insects No moving parts, eliminates freezing or sticking potential duct collar, white plastic LT As above - 6 option As above - 7 option Two 6" diameter hoods without sleeve or collar Flow-Thru Humidifier Suits any forced warm air heating system Unique electronically pulsed; reduces water consumption by up to 80% Left/right side flexible duct installation; mounts on supply or return duct 99-Flothru Electronic controller pulses solenoid water supply valve for 4 sec ON and 30 sec OFF, allowing evaporator pad to be fully saturated while drastically limiting water waste. Bathroom Exhaust System (BES) Exhausts multiple areas quietly and economically, while providing heat recovery thru the CAF. Includes: BES Control box, 4/5/6 Combi Fan, Fan speed selection. 99-CAF-BESKIT Perfect way to ventilate specific locations with a Clean Air Furnace. In-Line Duct Heater Equipped with highly advanced Electronic Modulating Controller (SCR) and Air Flow Sensor to minimize operating cost 120V, 1 phase Automatic reset prevents overheating, manual reset, coil elements made of nickel-chrome resistance wire, corrosionresistant galvanized steel enclosure, air flow sensor, built-in electronic temperature control and sensor, round collars simplify installation and reduce labour time diameter, 1KW, 120V/1phase 7 diameter, 2KW, 120V/1phase 6 diameter, 1KW, 120V/1phase 6 diameter, 2KW, 120V/1phase Special Orders. Call for info. Allows HRV to recover maximum heat, and duct heater modulates output required to reheat air to the desired temperature. This system is generally only used when the HRV has a fully dedicated duct system. Scrubber Air Treatment System Combats wood smoke, outside odours, dust, pollen and airborne pollutants from entering the home. Pre-filter mesh polyester fibre traps larger particles Media Filter is a large (50mm/2in) pleated filter Activated carbon filters function as purifying absorption nets, trapping odours and impurities. Includes: 1 pre-filter, 1 pleated filter, and 5 carbon filters ports; includes one filter pack 7 ports; includes one filter pack Filter pack replacement Scrubber is installed after the HRV/ERV in supply air. Freshvent Air-to-Air Exchanger Ventilates during low speed or hihh speed operation 2 speed motor Washable foam filter DX DXB DXPRO 35 CFM ventilation 70 CFM ventilation 85 CFM ventilation Summer Core Unique design allows air to pass through without transferring heat. Slides in place of existing heat exchange core Designed to take advantage of free outdoor cooling for use in climates with cooler summer night air.

64 61 Accessorie s

65 Accessori es ACCESSORIES EasyAir Grilles and Fittings Features Part Number Description TechGrille Fully adjustable ventilation grille. Center adjustment cone spins In-and-out, providing variable ventilation capacity. No screws required. Compression spring tabs clip the grille into 4, 5, 6 or 8 round duct. Cool white, non-corrosive material 99-EAG4 99-EAG5 99-EAG6 99-EAG8 4 diameter 5 diameter 6 diameter 8 diameter Stack Head Elbow Adapts to 4 /6 Tech Grille (see above) Fits neatly in 2 x4 walls Quick rough-in, and easy to secure 99-WF4 99-WF6 4 elbow 6 elbow Quick Mount Fittings All plastic design, will not sweat or rust Simple to install, saves time Suitable for ceiling or wall applications 99-QM4 99-QM5 99-QM6 4 diameter 5 diameter 6 diameter Ceiling/Wall Fittings Complements Tech Grille; choose size to match Cool white, all plastic design 99-CF4 99-CF5 99-CF6 99-CF-8 4 diameter 5 diameter 6 diameter 8 diameter Rough In Metal Fitting Metal Straps onto floor joists Available in 4 sizes 99-RIMF4 99-RIMF5 99-RIMF6 99-RIMF8 4 diameter 5 diameter 6 diameter 8 diameter Lay In Ceiling Diffuser Full adjustable air flow Non-sweating, won t rust or dent White finish, paintable, washable 99-LIP8 Fits 8 round duct Kitchen Grille White, Hinged 6 x10 exhaust grille. Easy access to washable aluminum grease filter (included) Kit, includes 1 grease filter. Replacement Grease filter only 62

66 Accessorie s ACCESSORIES Installation and Replacement Accessories Features Part Number Description Hanging Strap System INCLUDED with all MAX & RNC products (except RNC 120D) Easy mount system enables pre-assembly on floor Adjustable clip simplifies leveling procedure Includes 4 heavy duty straps and 4 S-hooks Airflow Measuring Equipment Flow Measuring Station Balancing Kit (Flow Station Style): Magnehelic gauge. Includes flow stations, hoses and carrying case Diameter 6 Diameter 7 Diameter 8 Diameter Pitot Tube Balancing Kit, Magnehelic gauge, Pitot Tube, Hoses and Carrying Case Diameter 6 Diameter Kit Pitot Tube only Balancing kit for models 155 MAX, 200 MAX and RNC5-TPD Magnehelic Gauge only. HRV Miscellaneous.5 ID Clear flexible vinyl drain hose, 100 /box 6 Diameter Balancing Collar 6 Spring-Loaded Back-draft Damper RSK6 Also available in 4/5/8/10/12 diameters Merv 8 Pleated filter Pack (6) 99-MERV8-6 Note: Not compatible with 95MAX, 195/300DCS. 6 Duct Silencer 99-SILENCER-6 6 port Mitre Elbows 4 Diameter, Plastic 4 Diameter, Galvanized 5 Diameter, Galvanized 6 Diameter, Galvanized P Lint Trap Lint Trap. Pull out door with view window Metal, with removable 2 ply lint screen TFP Accessories Replacement TFP3000 Collector Replacement HEPA Filter (for TFP3000) Installation Kit. Replacement filter kit (for TFP2000) R R 99-7TFP Annual replacement recommended Replace every 2-3 years. Includes 7 Flex Duct, 2 7 Collars, 4 Nylon Ties. 6 Filters approx 20 x20 x1. 63

67 Controls and Timer s 64

68 Controls and Timer s ACCESSORIES Lifestyle Controls Included with all MAX units Optional upgrade on MAX units Optional on RNC 99-DXPL01 Digital Control 5-speed operation 4 user operational modes - continuous ventilation - 20 min. ON, 40 min. OFF - 20 min. ON, 40 min. recirculation* - Continuous recirculation* *Not available on all models Built-in interface to furnace Automatic service reminder Automatic control based on outdoor temperature sensing. 99-LS01 Programmable Control 99-DX01Digital Control All Features of 99-DXPL01, plus: 4 selectable operational modes* DELUXE fully featured 5-speed, *Not available on all models 4 mode unit. 2 speed operation on each mode Fully PROGRAMMABLE, 4-event Adjustable dehumidistat function feature allows customization Dehumidistat disable according to lifestyle. 99-BC01 Ventilation Control 2 Speed operation Standby Unit On/Off Dehumidistat 99-DH01 Dehumidistat Initiates high speed ventilation when the indoor humidity level is above the set point. Optional on RNC Optional on RNC Timers 99-DET01 20/40/60 Minute Timer Initiate high speed operation for 20, 40 or 60 minutes M01 20 Minute Timer Initiates high speed operation for 20 minutes. (Both timers available on MAX and RNC Series) 65

69 Selecti on SELECTION Selecting the Right Size HRV RESIDENTIAL Applications The home ventilation system can be sized using room counts or by using whole-house ventilation. Using a whole-house ventilation rate of 0.3 ACH (Air Changes per Hour) the HRV CFM has been determined for the following homes (basement included in calculations). Condominium (800 sq. ft.) 800 sq.ft. x 8'h (6,400 cu.ft.) 6,400 cu. Ft./60 (106 CFM) 106 CFM x 0.3 ACH (32 CFM) Bungalow (2,800 sq. ft.) 2,800 sq.ft. x 8'h (22,400 cu.ft.) 22,400 cu. Ft./60 (373 CFM) 373 CFM x 0.3 ACH (112 CFM) Two Storey (4,800 sq. ft.) 4,000 sq.ft. x 8'h (32,000 cu.ft.) 32,000 cu. Ft./60 (534 CFM) 534 CFM x 0.3 ACH (160 CFM) Two Storey (5,500 sq. ft.) 5,500 sq.ft. x 8'h (44,000 cu.ft.) 44,000 cu. Ft./60 (733 CFM) 733 CFM x 0.3 ACH (220 CFM) Square Footag CFM Ceilin e (Includi required ng Baseme based on g RNC RECOMMENDED RESIDENTIAL HRV 155 MAX 155 MAX RX RNC 155 ECM RNC MAX 200 MAX 300 RX RNC 200 Pacific Conditions Arid Zone Dry Climate HRV Recommended Severe Conditions Moderate Conditions ERV Recommended Extreme Area High Humidity ERV s recommended in regions where high humidity causes operation of air conditioning/dehumidification more frequently than a heating system. ERV s are not recommended where temperatures fall below 25 ºF (-4 ºC) for more than five days. COMMERCIAL & INDUSTRIAL Applications For outdoor air requirements, ASHRAE has produced the Ventilation Standard that is used to determine acceptable ventilation rates. This standard is referenced directly or used as "Good Engineering practice" in most Code documents or design criteria. Small Bar, Health Club, Classrooms & Large Restaurants, Beauty & Cocktail Dance Club, School Portables Public Coffee Shops Nail Salon Lounge Disco (Age 9+) Venue Occupants Staff Total ASHRAE req (per person) 10 CFM (5L/s) 20 CFM (10L/s) 7.5 CFM (3.75L/s) 20 CFM (10L/s) 10 CFM (5L/s) 5 CFM (2.5L/s) Ventilation req (total xashrae) 450 cfm (225 L/s) 460 cfm (230 L/s) cfm ( L/s) 4000 cfm (2000 L/s) 360 cfm (180 L/s) 750 cfm (375 L/s) 66

70 Selectio n SELECTION Selecting the Right Size CAF / Air Handler CLEAN AIR FURNACE - Hydronic Add on A/C Model Description Output Range Capacity (Tons) STANDARD PSC MOTOR CAF-U-S4A-24-P16 CAF-U-L4A-36-P16 CAF-U-L2A-48-P16 CAF-D-S4A-24-P16 CAF-D-L4A-36-P16 CAF-H-S4A-24-P16 CAF-H-L4A-36-P16 Upflow Downflow Horizontal 34,000 to 85,000 38,000 to 110,000 25,000 to 68,000 34,000 to 85,000 38,000 to 110,000 34,000 to 85,000 38,000 to 110,000 CAF-U P16 Upflow N0 Heat 2 CAF-U P16 3 CAF-U P16 4 UPGRADE ECM MOTOR CAF-U-S4A-24-E16 Upflow 34,000 to 85,000 2 CAF-U-L4A-36-E16 CAF-U-L2A-48-E16 CAF-H-S4A-24-E16 CAF-H-L4A-36-E16 99-CAF-BESKIT 38,000 to 110,000 25,000 to 68,000 Horizontal 34,000 to 85,000 38,000 to 110, Kit (3-items) Includes: BES control box, Quantum 4/5/6 Combi Fan, Fan speed selection The Lifebreath Hydronic Clean Air Furnace uses the heat from a hot water heater or boiler system to warm the circulating air. Air returning to the furnace passes through an integral heat recovery ventilator. Users enjoy a constant supply of fresh healthy air and minimal energy costs. ECM motor is recommended by the manufacturer for both new and retrofit construction. SELECTING THE CORRECT AIR HANDLER Add on A/C Model Description Output Range Capacity (Tons) HYDRONIC AH-U-S4A-24-P16 AH-U-L4A-36-P16 AH-U-S2A-30-P16 AH-U-L2A-36-P16 AH-U-L2B-48-P16 Lifebreath Academy Upflow 34,000 to 85,000 38,000 to 110,000 27,000 to 56,000 25,000 to 68,000 38,000 to 79, The Lifebreath Air Handler is a forced air combo type heating system. Combo systems use the hot water supplied by a water heater or boiler. Thus, only one heating appliance is needed to meet hot water and home heating demands. System maximizes efficiency by minimizing "stand-by losses." When heat is required, hot water is circulated through the coil in the air handler and air blown through the coil picks up the heat and delivers to the home. The water is then returned to the water heater for water or heating use. Our Residential HRV course and Membership helps prepare you for the installation and promotion of Lifebreath Heat Recovery Ventilators. HRV Duct Sizing Software is included with the course materials. The topics covered include: - benefits of ventilation - calculating the amount of ventilation required - designing a simplified, partially dedicated, and fully dedicated duct system - correctly sizing the system - selecting the controls Successful completion of the course and exam qualifies you to promote yourself as a "factory trained" member of the Lifebreath Academy. Membership also qualifies you to participate in Lifebreath's customer referral program. Visit for more information or speak to your local Territory Manager. 67

71 Terms and Conditio ns TERMS AND CONDITIONS Terms and Conditions TERMS OF SALE 1. Payment: Net 30 days, from invoice date. 2. Canadian Customers Taxes: a. G.S.T. will be charged on all products, and shown separately on each invoice. b. P.S.T (where/as applicable) are extra and will be charged unless AIRIA is supplied with a Provincial Sales Tax license number. c. H.S.T (where/as applicable) will be charged on all products, and shown separately on each invoice. 3. U.S. & International Customers a. Federal I.D. # is mandatory for all shipments. b. Taxes not applicable. 4. Ownership of the product remains the property of AIRIA until the invoice is paid in full. SHIPPING AND DELIVERY 1. Order lead times (target timeframes): Residential units as little as 5 business days Commercial 10 business days Large Commercial business days Parts 2 business days 2. To protect your product during transport, protective packaging, containers or skids can increase shipping weight by 5-20%. Exact weight can be confirmed at time of order. 3. All orders are shipped via courier, and delivered during normal business hours. Shipping charges are included to most major centers in the U.S. Additional charges may apply for shipments beyond those centers. You will be notified of extra charges prior to order entry. 4. We regret that we cannot ship to a Post Office (P.O.) Box address. PRICING See pricing lists (available separately) for details FREIGHT CLAIMS 1. All return Freight charges are the responsibility of the sender. 2. Extra freight duty or brokerage costs charged to Airia Brands Inc., will be deducted from your credit. TO PLACE AN ORDER FAX PURCHASE ORDER: For Order Information: PH: 855-AIRIA-00 ( ) GOODS RETURNED FOR CREDIT 1. Authorization must be obtained prior to returning any goods. Use the Return Goods Authorization Form (SM-01F) found on the front of the parts list. 2. Once authorized you will receive an RMA number/#; this RMA number/# must be tagged on the returned product. 3. Returned products must be freight prepaid and adequately packaged to prevent damage. If damaged or unusable, credit will be denied. 4. A minimum 15% restocking charge will apply. 5. Custom products and non-stock products are non-returnable and non-refundable. 6. AIRIA reserves the right to refuse any request for return. WARRANTY POLICY, REPLACEMENT PARTS, RETURNS Airia Brands Inc. is proud to stand behind our products. Should replacement parts be required, while under warranty, they will be provided at no charge. Refer to the warranty card enclosed with the product. Replacement parts installed in units under warranty will assume the original machine warranty remaining OR one year, whichever is longer. Note, warranty is for parts only. Freight or labor incurred is the responsibility of the homeowner. Refer to the warranty card enclosed with the product manual documentation. Should a warranty claim for replacement parts be necessary, please complete the following procedure: 1. Replacement warranty parts are invoiced on order. 2. When defective parts are ready for return for warranty credit, complete RMA Form SM-01F noting the machine model, serial number, date and explanation of failure. 3. Fax completed form for authorization before returning defective parts to Airia. Defective parts being returned must have an authorized SM-01F to receive credit. 4. Upon authorization, return the completed form together with the defective part, Pre-Paid. U.S. returns should be sent via Postal service (versus courier). 5. Address your prepaid, insured package to: Airia Brands Inc, Attn: Returns, 511 McCormick Blvd, London, Ontario, Canada N5W 4C8. COD deliveries will not be accepted. 6. After completing the above, your account will be credited within 30 days. 68

72 Partner Co-op Advertising Sample (Contact your Territory Manager for more details) Leading the Way to Total Home Comfort... by improving your indoor air quality, and reducing energy consumption. Are you ready to step up to Lifebreath? (Name of Dealer) carries our full line including our high efficiency Hydronic air handler with built-in air exchanger, the TFP HEPA Air Cleaner and the industry leading HRV with patented aluminum core. Lifebreath products are designed for one reason - to give your home or business a healthier indoor air environment. Visit any of our locations and let (Name of Dealer) show you how. Setting a new standard for energy efficient, clean air homes Let us show you how to give your home or business a healthier indoor air environment. Visit us at McCormick Blvd., London, ON, Canada N5W 4C8 (519) My Street Our Town, ON A4B 5C6 (789) Residential Warranty Commercial Warranty We proudly stand behind our products with a Full Warranty. LIFETIME on HRV aluminum cores 5 YEAR on ERV Enthalpic cores 5 YEAR on replacement components We proudly stand behind our products with a Full Warranty. 15 YEAR on HRV aluminum cores 5 YEAR on the ERV Enthalpic cores 2 YEAR limited on replacement components

73 Setting a new standard for energy efficient, clean air homes 511 McCormick Blvd. London, Ontario, Canada N5W 4C8 Ph: (519) Toll Free: AIRIA-00 ( ) Manufacturer reserves the right to change specifications without notice. Printed in Canada 98-CATLB (05-11)

Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics. RNC Series. Residential Heat Recovery Ventilators (HRV)

Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics. RNC Series. Residential Heat Recovery Ventilators (HRV) Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics RNC Series Models RNC95 RNC155 RNC200 RNC10 RNC20 RNC120D RNC5-TPD Residential Heat Recovery Ventilators (HRV) Manufactured

More information

Max Series 5 Speed Electronics Lifestyle MAX Digital Control included

Max Series 5 Speed Electronics Lifestyle MAX Digital Control included Operation and Installation Manual Max Series 5 Speed Electronics Lifestyle MAX Digital Control included 95MAX* 155MAX 155ECM* 155MAXRX 200MAX* 200MAXRX* 195DCS* 195ECM* 300DCS* Residential Heat Recovery

More information

COMMERCIAL HRV OPERATION AND INSTALLATION 69-COMHRV FD/DD, 650FD/DD, 700FD/DD, 1200FD/DD

COMMERCIAL HRV OPERATION AND INSTALLATION 69-COMHRV FD/DD, 650FD/DD, 700FD/DD, 1200FD/DD COMMERCIAL HRV OPERATION AND INSTALLATION 455FD/DD, 650FD/DD, 700FD/DD, 1200FD/DD 69-COMHRV 011118 511 McCormick Blvd. London, ON Canada N5W 4C8 General Info/Tech Support: 1 855. 247 4200 Online: www.lifebreath.com

More information

HEALTHY CLIMATE Heat / Energy Recovery Ventilator

HEALTHY CLIMATE Heat / Energy Recovery Ventilator PRODUCT SPECIFICATIONS INDOOR AIR QUALITY HRV / ERV HEALTHY CLIMATE Heat / Energy Recovery Ventilator Bulletin No. 210528 November 2017 Supersedes March 2017 HRV5-150 ERV3-150, -200 HRV3-150-TPD/TPF, HRV5-200-TPD

More information

INSTALLATION GUIDE. Horizontal series. HRV MODEL 8160 and MODEL 8220 ERV MODEL 3160 and MODEL 3220

INSTALLATION GUIDE. Horizontal series. HRV MODEL 8160 and MODEL 8220 ERV MODEL 3160 and MODEL 3220 INSTALLATION GUIDE Horizontal series HRV MODEL 8160 and MODEL 8220 ERV MODEL 3160 and MODEL 3220 INSTALLATION GUIDE Peace of Mind All GeneralAire products are backed by the best limited warranty in the

More information

Operation and Installation Manual. Models 330ERV 530ERV 730ERV 1230ERV. Commercial Energy Recovery Ventilators (ERV) 69-ComERV

Operation and Installation Manual. Models 330ERV 530ERV 730ERV 1230ERV. Commercial Energy Recovery Ventilators (ERV) 69-ComERV Operation and Installation Manual Models 330ERV 530ERV 730ERV 1230ERV Commercial Energy Recovery Ventilators (ERV) 69-ComERV 032717 Table of Contents The Benefits of ERVs Location of the ERV for Mounting...

More information

HEAT RECOVERY VENTILATOR

HEAT RECOVERY VENTILATOR HEAT RECOVERY VENTILATOR CONSTRUCTO 1.0 HRV Part no. 41502 (TOP PORTS) Part no. 41500 (SIDE PORTS) 39 to 98 CFM (0.4 in. w.g.) VB0069 AN INGENIOUS AIR EXCHANGE SOLUTION THAT S AS VERSATILE AS IT IS COMPACT!

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Energy Recovery Ventilator (ERV) STANDARD 5 YEAR PARTS LIMITED WARRANTY When installed and registered with a complete Maytag system, this product carries a 12 Year All Parts Warranty.

More information

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home. HRV / ERV Heat or Energy Recovery Ventilation Systems You need fresh air, so does your home. Control Your Indoor Air Quality Following the energy crisis of the 1970s, we tended to insulate our homes and

More information

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home. HRV / ERV Heat or Energy Recovery Ventilation Systems You need fresh air, so does your home. Control Your Indoor Air Quality Following the energy crisis of the 1970s, we tended to insulate our homes and

More information

INDOOR AIR QUALITY KITS AND ACCESSORIES /2014. Supersedes 06/2014

INDOOR AIR QUALITY KITS AND ACCESSORIES /2014. Supersedes 06/2014 INDOOR AIR QUALITY KITS AND ACCESSORIES 507363-01 08/2014 Supersedes 06/2014 HEALTHY CLIMATE HRV & ERV VENTILATORS INSTALLATION INSTRUCTIONS & HOMEOWNERS GUIDE FOR HEALTHY CLIMATE HEAT RECOVERY VENTILATOR

More information

Residential and Commercial HRVs & ERVs. Heat Recovery Ventilators & Energy Recovery Ventilators

Residential and Commercial HRVs & ERVs. Heat Recovery Ventilators & Energy Recovery Ventilators Residential and Commercial HRVs & ERVs Heat Recovery Ventilators & Energy Recovery Ventilators Residential HRVs - Horizontal Recirculating Defrost SUPERVENTOR SERIES Color coded collars easily identify

More information

Residential and Commercial HRVs & ERVs. Heat Recovery Ventilators & Energy Recovery Ventilators

Residential and Commercial HRVs & ERVs. Heat Recovery Ventilators & Energy Recovery Ventilators Residential and Commercial HRVs & ERVs Heat Recovery Ventilators & Energy Recovery Ventilators Residential HRVs - Horizontal Recirculating Defrost SUPERVENTOR SERIES Color coded collars easily identify

More information

INDOOR AIR QUALITY KITS AND ACCESSORIES /12 Supersedes 05/12

INDOOR AIR QUALITY KITS AND ACCESSORIES /12 Supersedes 05/12 INDOOR AIR QUALITY KITS AND ACCESSORIES 506239 01 Supersedes 05/12 Litho U.S.A. HEALTHY CLIMATE HRV & ERV VENTILATORS INSTALLATION INSTRUCTIONS & HOMEOWNERS GUIDE FOR HEALTHY CLIMATE HEAT RECOVERY VENTILATOR

More information

Installation Guide. MAX Series. 69-MAX-Install Setting a new standard for energy efficient, clean air homes

Installation Guide. MAX Series. 69-MAX-Install Setting a new standard for energy efficient, clean air homes MAX Series Installation Guide Setting a new standard for energy efficient, clean air homes 69-MAX-Install 012616 511 McCormick Blvd London, Ontario Canada N5W 4C8 519.457.1904 General Info / Tech Support:

More information

Indoor Air Quality Product Brochure.

Indoor Air Quality Product Brochure. Indoor Air Quality Product Brochure Ventilation: A vital system for a healthy home All homes require adequate ventilation for the safety of their occupants and to remove excess humidity, airborne pollutants

More information

InspirAIR Compact Heat and Energy Recovery. Multi-Family HRV/ERV

InspirAIR Compact Heat and Energy Recovery. Multi-Family HRV/ERV Inspir Compact Heat and Energy Recovery Multi-Family HRV/ERV High-Profile Performance & Low-Profile Design Small spaces demand smart technology. Aldes Inspir Compact Heat and Energy Recovery Ventilators

More information

Indoor Air Quality Product Brochure.

Indoor Air Quality Product Brochure. Indoor Air Quality Product Brochure Ventilation: A vital system for a healthy home All homes require adequate ventilation for the safety of their occupants and to remove excess humidity, airborne pollutants

More information

Clean Air Furnace. Finalist Canada s National Energy Efficiency Awards

Clean Air Furnace. Finalist Canada s National Energy Efficiency Awards Finalist Canada s National Energy Efficiency Awards Enjoy the comfort and economy of fresh, warm air throughout your home with the new Lifebreath Clean Air Furnace Clean Air Furnace Lifebreath delivers

More information

ENERGY RECOVERY VENTILATOR

ENERGY RECOVERY VENTILATOR ENERGY RECOVERY VENTILATOR ERV 60H Part no. 606 (TOP PORTS) Part no. 60 (SIDE PORTS) 5 to 05 CFM (0. in. w.g.) VB0073 AN INGENIOUS AIR EXCHANGE SOLUTION THAT S AS VERSATILE AS IT IS COMPACT! Configured

More information

MODELS LT15 & LT20 INSTALLATION INSTRUCTION FOR HEAT RECOVERY VENTILATOR (HRV)

MODELS LT15 & LT20 INSTALLATION INSTRUCTION FOR HEAT RECOVERY VENTILATOR (HRV) MODELS LT15 & LT20 INSTALLATION INSTRUCTION FOR HEAT RECOVERY VENTILATOR (HRV) Shipping and Packing List Package 1 of 1 contains: 1 - Assembled ventilator 1 - Bag assembly containing: 2 - Drain spout assemblies

More information

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS ENERGY-SAVING VENTILATION SOLUTIONS TO IMPROVE INDOOR AIR QUALITY Quality Features Built Into Every Model Compact

More information

Your complete source of information on Venmar AVS air exchangers. Constructo: 1.0 / 1.5 / 2.0 Solo: 1.5 / 2.0 Duo: 1.2 / 1.4 / 1.9 HE: 1.3 / 1.8 / 2.

Your complete source of information on Venmar AVS air exchangers. Constructo: 1.0 / 1.5 / 2.0 Solo: 1.5 / 2.0 Duo: 1.2 / 1.4 / 1.9 HE: 1.3 / 1.8 / 2. RANGE HOODS ATTIC VENTILATORS AIR EXCHANGERS DELUXE RANGE HOODS For more than 25 years, Venmar Ventilation has been one of North America s leading manufacturers of innovative Indoor Air Quality products

More information

Residential Heat & Energy Recovery

Residential Heat & Energy Recovery Residential Heat & Energy Recovery Aeromatic Series Standard Residential HRV/ERV 95-215 CFM 2 Discover Heat & Energy Recovery A tightly built, high-performance home is a great way to conserve energy and

More information

Limited Lifetime core warranty. 5-year warranty on balance of unit.

Limited Lifetime core warranty. 5-year warranty on balance of unit. MODEL FEATURES Polypropylene HRV core 3 operating modes Painted galvanized steel case Designed for simple installation by a single person Fully insulated case Limited lifetime warranty on the heat recovery

More information

VERTICAL FAN COIL UNITS

VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS Model: CT & TCE 2 - Pipe 350 cfm to 1200 cfm capacity 4-row water coil 120v or 24v controls Electric heating coil (TCE Model) Fresh air connection from remote

More information

10-year industry best core warranty. 5-year warranty on balance of unit.

10-year industry best core warranty. 5-year warranty on balance of unit. MODEL TR MODEL FTURES MERV-8 filters Less than 1 watt stand-by power consumption Transformer/relay package allowing simple on/off control Plastic double collars for 6 or 8 direct duct connection (TR300

More information

69-CAF. Models. Operation, Sizing and Installation Manual. Hydronic Models with Built-in Heat Recovery Ventilator (HRV)

69-CAF. Models. Operation, Sizing and Installation Manual. Hydronic Models with Built-in Heat Recovery Ventilator (HRV) Operation, Sizing and Installation Manual Models CAF-U-S4A-24-P16 (E16) CAF-D-S4A-24-P16 (E16) CAF-H-S4A-24-P16 (E16) CAF-U-L4A-36-P16 (E16) CAF-D-L4A-36-P16 (E16) CAF-H-L4A-36-P16 (E16) CAF-U-L2A-48-P16

More information

Modular Supply Make-Up Air Unit

Modular Supply Make-Up Air Unit Modular Supply Make-Up Air Unit Model MSX Flexible Design Factory Assembled Heating Options Hot Water Steam Electric Cooling Options Evaporative Direct Expansion Chilled Water November 2009 Product Features

More information

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits RESIDENTIAL SYSTEM SOLUTIONS VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits VentZone Zoned IAQ Kits with Energy Recovery combine a Standard Residential Energy Recovery Ventilator (ERV) with

More information

SAFETY AND INSTALLATION MANUAL MODEL 8100

SAFETY AND INSTALLATION MANUAL MODEL 8100 SAFETY AND INSTALLATION MANUAL ENERGY RECOVERY VENTILATORS MODEL 8100 Provides year-round fresh air Recovers 77% of the apparent heating or cooling energy from the exhausted air See Warnings Page 3 Table

More information

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits RESIDENTIAL SYSTEM SOLUTIONS VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits VentZone Zoned IAQ Kits with Heat Recovery combine a Standard Residential Heat Recovery Ventilator (HRV) with residential

More information

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS With S&P s TR & TRC (total recovery) Series for all climates, stale room air is exhausted and fresh outdoor air is brought back into the house. These two air streams are directed through a highly developed

More information

Energy Recovery with Cooling and Heating Model ERCH

Energy Recovery with Cooling and Heating Model ERCH Energy Recovery with Cooling and Heating Model ERCH 100% Outdoor Air System Dedicated Outdoor Air System 1,000-10,000 cfm 1.75 in. wg External Static Pressure Indirect Gas, Hot Water, Electric Heating,

More information

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS With S&P s TR & TRC (total recovery) Series for all climates, stale room air is exhausted and fresh outdoor air is brought back into the house. These two air streams are directed through a highly developed

More information

Light commercial models

Light commercial models Installation Manual Item #: 422468 Rev Date: 051414 Light commercial models Energy Recovery Ventilators SER 5504 SER 8504 SER 11504 Your ventilation system should be installed in conformance with the appropriate

More information

Ventilation Solutions IAQ Canada

Ventilation Solutions IAQ Canada Ventilation Solutions IAQ Canada 2 Ventilation Solutions IAQ Ventilation Solutions IAQ 3 Indoor Air Quality Keep your family safe Safeguard Your Home Three easy steps Your home should be safe and comforting,

More information

MiniCore Ventilator (500, 1000) Series Engineering Guide

MiniCore Ventilator (500, 1000) Series Engineering Guide MiniCore Ventilator (500, 1000) Series Engineering Guide November 2017 V1.0 Johnson Controls, Inc. All rights reserved. TABLE OF CONTENTS Page Functionality and Benefits... 1 Unit Overview... 3 MiniCore

More information

Ventilation Solutions IAQ Canada

Ventilation Solutions IAQ Canada Ventilation Solutions IAQ Canada 2 IAQ Canada Indoor Air Quality Keep your family safe What s All The Talk About Indoor Air Quality? What The Experts Say: You ve heard it on TV and read about it in magazines.

More information

IAQ VENTILATION SOLUTIONS

IAQ VENTILATION SOLUTIONS IAQ VENTILATION SOLUTIONS HEAT RECOVERY VENTILATORS ENERGY RECOVERY VENTILATORS WHOLE HOUSE HEPA FILTRATION I M P R O V I N G I N D O O R A I R Q U A L I T Y T H R O U G H B E T T E R V E N T I L A T I

More information

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating Rooftop Ventilator with Packaged Cooling & Heating Models RV and RVE Institutional Commercial Industrial 800-1,500 cfm.0 in. wg External Static Pressure Indirect Gas, Hot Water, Electric Heating Packaged

More information

Product Data HRV A10299

Product Data HRV A10299 HRVCCLHA Heat Recovery Ventilator ERVCCLHA Energy Recovery Ventilator Product Data A10299 The Heat Recovery Ventilation (HRV) and Energy Recovery Ventilator (ERV) systems offered by Carrier are the finest

More information

Operation, Sizing and Installation Manual Hydronic Models with Built-in Heat Recovery Ventilator (HRV)

Operation, Sizing and Installation Manual Hydronic Models with Built-in Heat Recovery Ventilator (HRV) Operation, Sizing and Installation Manual Models CAF-U-S4A-24-P16 (E16) CAF-D-S4A-24-P16 (E16) CAF-U-L4A-36-P16 (E16) CAF-D-L4A-36-P16 (E16) CAF-U-L2A-48-P16 (E16) CAF-U-00-24-P16 (E16) CAF-U-00-36-P16

More information

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini... Contents How to choose Recovery Ventilation type?............................................3 How do HRV, ERV and TRV Systems work?............................................4 Types of installations..............................................................5

More information

Heat Recovery Ventilator Model PVe Light Industrial Commercial Institutional

Heat Recovery Ventilator Model PVe Light Industrial Commercial Institutional Heat Recovery Ventilator Model PVe Light Industrial Commercial Institutional 1,000-6,000 cfm 2.0 in. wg External Static Pressure Aluminum Plate Heat Exchanger April 2017 Heat Recovery Ventilators Greenheck

More information

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS. PRODUCT SPECIFICATIONS INDOOR AIR QUALITY HCWHD Healthy Climate Whole-Home Dehumidifier Bulletin No. 210699 November 2017 Supersedes April 2017 MODEL NUMBER IDENTIFICATION Nominal Capacity - 70 to 130

More information

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Internal ridged board 1 x 1.5 foil face installation shall be installed on roof, walls and base of casing. A-D WITH MPU SPECIFICATION WRITTEN SPECIFICATION Description A Modular Packaged Heating, Cooling and ventilating unit(s), as indicated on the drawings shall be furnished. Direct Fired Gas Unit(s) shall

More information

IAQ VENTILATION SOLUTIONS

IAQ VENTILATION SOLUTIONS IAQ VENTILATION SOLUTIONS HEAT RECOVERY VENTILATORS ENERGY RECOVERY VENTILATORS WHOLE HOUSE HEPA FILTRATION IMPROVING INDOOR AIR QUALITY THROUGH BETTER VENTILATION July 2006 IAQ0706 www.fantech.net What

More information

SER Models. SER Series Energy Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

SER Models. SER Series Energy Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT SER Series Energy Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT CAUTION - Before installation, careful consideration must be given to how this system will operate if connected

More information

Light Commercial Heat/Energy Recovery Ventilator

Light Commercial Heat/Energy Recovery Ventilator Light Commercial Heat/Energy Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT R CC R US CAUTION - Before installation, careful consideration must be given to how this system

More information

BROAN ERVS100 Part no. ERVS100S CFM (0.4 in. w.g.)

BROAN ERVS100 Part no. ERVS100S CFM (0.4 in. w.g.) BROAN ERVS100 Part no. ERVS100S 65-105 CFM (0.4 in. w.g.) Product balancing The ERVS100 is equipped with 2 high static pressure blowers and is factory balanced. At installation, the ERVS100 will remain

More information

SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT CAUTION - Before installation, careful consideration must be given to how this system will

More information

Supplying Clean Air to Industry

Supplying Clean Air to Industry Next Generation MistBuster : 500, 500 Media, 850, 2000, Infinity Supplying Clean Air to Industry The MistBuster family of self-contained mist removal systems is designed to capture mist and smoke from

More information

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog H3/V3 Series Horizontal and Vertical Indoor Air Handling Units Engineering Catalog Table of Contents AAON H3/V3 Series Features and Options Introduction... 6 H3/V3 Base Model Description... 7 Unit Size...

More information

Q-TEC QC-Series Chilled Water Air Conditioner

Q-TEC QC-Series Chilled Water Air Conditioner Cooling Capacities: 13,3 to 49,3 BTUH (Based on EWT, GPM & CFM) Q-TEC QC-Series Chilled Water Air Conditioner The Q-TEC Series self-contained packaged chilled water air conditioner is designed to be installed

More information

Q-Tec TM QC-Series Chilled Water Air Conditioner

Q-Tec TM QC-Series Chilled Water Air Conditioner Q-Tec TM QC-Series Chilled Water Air Conditioner Cooling Capacities:, to, BTUH (Based on EWT, GPM and ) The Q-Tec Series self-contained packaged chilled water air conditioner is designed to be installed

More information

Chilled Water DOAS Fan Powered Terminal Units

Chilled Water DOAS Fan Powered Terminal Units Chilled Water DOAS Fan Powered Terminal Units CHILLED WATER DOAS FAN POWERED TERMINAL UNITS DOAS TERMINAL UNITS FEATURES AND BENEFITS MINIMUM VENTILATION CONTROL The DOAS unit provides the Designer, Owner

More information

HR150, 200; ER150, 200 Perfect Window Fresh Air Ventilation Systems

HR150, 200; ER150, 200 Perfect Window Fresh Air Ventilation Systems HR50, 200; ER50, 200 Perfect Window Fresh Air Ventilation Systems FEATURES PRODUCT DATA APPLICATION The HR50B and HR200B Perfect Window Fresh Air Ventilation Systems provide proper levels of ventilation

More information

Heat or Energy Recovery Ventilation System

Heat or Energy Recovery Ventilation System INSTALLATION MANUAL Heat or Energy Recovery Ventilation System MODELS: FC80 HRV & FC80 ERV This device MUST be installed by a qualified agency in accordance with the manufacturer's installation instructions.

More information

Direct Gas-Fired Make-Up Air

Direct Gas-Fired Make-Up Air Direct Gas-Fired Make-Up Air Model TSU Heavy Duty, High Airflow Applications Manufacturing and Industrial Facilities Up to 64,000 cfm August 2012 Products Model TSU Direct Gas-Fired Make-Up Air Unit The

More information

The ultimate fresh air solution.

The ultimate fresh air solution. Fresh Access The ultimate fresh air solution. Introducing Fresh Access TM. Expertly designed, our innovative energy recovery ventilator (ERV) unit, split dedicated outside air system (DOAS), and packaged

More information

NU800, NU1200 & NU1600

NU800, NU1200 & NU1600 P.O. Box 2758 Windsor, Nova Scotia, B0N 2T0 Ph. 902 798 2261 Fax. 902 798 2557 www.nu-airventilation.com Email: nuair@nu-airventilation.com OPERATING, MAINTAINING & INSTALLING YOUR LIGHT COMMERCIAL HEAT

More information

TR Series - The Ultimate ERV

TR Series - The Ultimate ERV TR Series The Ultimate ERV Total Recovery for All Climates Featuring Vent Lights and Premium Grilles Fans s for f Life! The World s Leading Producer of Air Movement Products TR_0810 Indoor Air Quality

More information

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL PREPARED FOR: DATE: JOB NAME: WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL EQUIPMENT DETAILS ITEM TAG DESCRIPTION MODEL NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 EQUIPMENT

More information

INDOOR AIR QUALITY PRODUCT LINE CARD 10.18

INDOOR AIR QUALITY PRODUCT LINE CARD 10.18 INDOOR AIR QUALITY PRODUCT LINE CARD 10.18 VENTILATION PRODUCTS HRV HEAT RECOVERY VENTILATORS / ERV ENERGY RECOVERY VENTILATORS HRV Heat Recovery Ventilators HRV Series - Heat Recovery Ventilators MODELS

More information

Indirect Gas-Fired Make-Up Air

Indirect Gas-Fired Make-Up Air Indirect Gas-Fired Make-Up Air Model IG 800 to 7,000 cfm Up to 400,000 Btu/hr Multiple Furnace Control Options Optional Evaporative Cooling May 20041 Product Features Model IG Indirect Gas-Fired Make-Up

More information

FCC Fan-Coil Units High-Performance, Vertical

FCC Fan-Coil Units High-Performance, Vertical FCC Fan-Coil s High-Performance, Vertical Model FCC construction features Piping and supply-duct connections are from top of unit, eliminating the need for side or back access Right or left-hand configurations

More information

P.O. Box 2758 Windsor, Nova Scotia, B0N 2T0 Ph Fax:

P.O. Box 2758 Windsor, Nova Scotia, B0N 2T0 Ph Fax: P.O. Box 2758 Windsor, Nova Scotia, B0N 2T0 Ph. 902-798-2261 Fax: 902-798-2557 www.nu-airventilation.com email: nuair@nu-airventilation.com COMPLIANT SERIES HRV/ERV PRODUCT MANUAL NU0820/NU2035/NU2540/NU1030

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 93% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 93% AFUE, all models all positions F9MES 50 Hz Product Specifications Certified to leak 2% or less of nominal air conditioning CFM delivered when

More information

MODEL TRC TOTAL RECOVERY FOR ALL CLIMATES - COMMERCIAL APPLICATIONS

MODEL TRC TOTAL RECOVERY FOR ALL CLIMATES - COMMERCIAL APPLICATIONS TOTAL RECOVERY FOR ALL CLIMATES - COMMERCIAL APPLICATIONS MODEL FTURES MERV-8 filters Transformer/relay package allowing simple on/off control Access doors for easy access to blowers, core and filters

More information

Modular Heating & Ventilating Unit Model IGX-HV

Modular Heating & Ventilating Unit Model IGX-HV Modular Heating & Ventilating Unit Model IGX-HV Indirect Gas-Fired Heating Evaporative Chilled Water DX Cooling October 2008 Product Features Model IGX-HV Indirect Gas-Fired Heating and Ventilating Unit

More information

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation Industrial Space Heating Direct Gas-Fired Heating Greenheat 00% Outdoor Air Greenheat 50/50 Recirculation 80/0 Recirculation March 008 Product Overview Industrial Space Heating Greenheck s space heating

More information

Product Catalog Commercial Solutions US Edition

Product Catalog Commercial Solutions US Edition Product Catalog Commercial Solutions US Edition 2 Introduction Quality products, reliable service and leaders in innovation For more than 30 years, Fantech has been researching, designing and bringing

More information

Direct Fired Heater Model AD Specification

Direct Fired Heater Model AD Specification Direct Fired Heater Model AD Specification Description A Direct-fired gas heating and ventilating unit(s), as indicated on the drawings shall be furnished. Unit(s) shall be tested in accordance with ANSI

More information

REFLECTOR PANS FOR HINGED ELEMENTS CONNECTOR BLOCK KIT TRIM RINGS FOR ABOVE PANS CONNECTOR BLOCK RANGE CORD REFLECTOR PANS FOR PLUG-IN ELEMENTS

REFLECTOR PANS FOR HINGED ELEMENTS CONNECTOR BLOCK KIT TRIM RINGS FOR ABOVE PANS CONNECTOR BLOCK RANGE CORD REFLECTOR PANS FOR PLUG-IN ELEMENTS *s are Subject to Change without Notice.* REFLECTOR PANS FOR HINGED ELEMENTS Heavy Chromed Steel Description 2-1040 6" UNIVERSAL $2.19 2-1041 8" UNIVERSAL $2.89 2-1050 6" GE/HOTPOINT $2.39 2-1051 8" GE/HOTPOINT

More information

Energy Recovery Ventilators

Energy Recovery Ventilators Energy Recovery Ventilators ERV-150 ERV-200 IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT CAUTION - Before installation, careful consideration must be given to how this system will operate

More information

Wt. Lbs Model Number (BTUH) Hz

Wt. Lbs Model Number (BTUH) Hz Up to 96% AFUE, Two Stage ECM Gas Furnace EASIER TO SELL Up to 96% AFUE in upflow and horizontal positions F95% AFUE in downflow position California NOx approved Most models have earned the ENERGY STAR

More information

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS 7 Rosemex Products 97 VENTILATION CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS 2 INTRODUCTION Rosemex "Penthouse" units are essentially outdoor mechanical rooms. They group in one compact weather proof outdoor

More information

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com Greensource Residential Water Source Heat Pumps i Series: SV Model Simply Smart The i Series SV Model is a cost-effective single stage water source heat pump that is designed for commercial retrofit and

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) R9MSB Product Specifications 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning

More information

Product Catalog Commercial Solutions US Edition

Product Catalog Commercial Solutions US Edition Product Catalog Commercial Solutions US Edition 2 Introduction Quality products, reliable service and leaders in innovation For more than 30 years, Fantech has been researching, designing and bringing

More information

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges. Service Literature The LGH/LCH high and standard efficiency 5, 0, 5 and 50 ton (, 0.7, 58. and 75.9 kw) units, are configure to order units (CTO) with a wide selection of factory installed options. The

More information

SH, VH & SE Series. Installation, Operation and Maintenance Manual. Heat & Energy Recovery Ventilators SH 704 VH 704 SE 704

SH, VH & SE Series. Installation, Operation and Maintenance Manual. Heat & Energy Recovery Ventilators SH 704 VH 704 SE 704 Installation, Operation and Maintenance Manual Item #: 403165 Rev Date: 2017-09-26 SH, VH & SE Series Heat & Energy Recovery Ventilators SH 704 VH 704 SE 704 Your ventilation system should be installed

More information

Put the V back in HVAC

Put the V back in HVAC Put the V back in HVAC V is for Ventilation A system or means of providing fresh air. Webster New Collegiate Dictionary Benjamin Franklin so unwholesome as air in a closed room that has been often breathed

More information

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems Mission Critical Air Conditioning Systems vertical floor mount Series 6, 8 & 9 2-30 Ton Units Single Circuit for Superior Economy and Dual Circuit for Ultimate Protection Series 6 2-5 tons Compact Footprint

More information

Manufacturer of HVAC Equipment Since ,000 sq. ft. on 16 acres. Colton, California USA

Manufacturer of HVAC Equipment Since ,000 sq. ft. on 16 acres. Colton, California USA Manufacturer of HVAC Equipment Since 1916 400,000 sq. ft. on 16 acres Colton, California USA Visual factory Vertically integrated manufacturing BELT-DRIVEN AIR HANDLERS 800 12,000 CFM Horizontal Vertical

More information

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design Fan motor (PSC or ECM). UL Listed 1 insulation conforms to UL Test 181 and NFPA 90A. Plenum air filter rack. (Filter Optional) Casing has

More information

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S USER S MANUAL Heat (Energy) Recovery Ventilator Vents Frigate HRV 120 S Vents Frigate ERV 120 S 2 Frigate HRV(ERV) 120 S CONTENT Introduction... 3 Application... 3 Delivery set... 3 Unit designation key...

More information

Electric Heat - Air Curtains

Electric Heat - Air Curtains 06/09/13 A25-2 Electric Heat - Air Curtains Air Curtain - SDC Series Power High/Low (Watts) Volts Phase (nb.) Power High/Low (Btu/h) Ideal for commercial installations, this air curtain is very powerful!

More information

NUWAVE SERIES. Residential Central Heat Recovery Ventilator Product Specifications and Installation and User Manual NuWave Series Models

NUWAVE SERIES. Residential Central Heat Recovery Ventilator Product Specifications and Installation and User Manual NuWave Series Models NUWAVE NUWAVE SERIES Residential Central Heat Recovery Ventilator Product Specifications and Installation and User Manual NuWave Series Models NW130, NW140, NW160, NW220, NW260 BY: APPLICATION WARNING

More information

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 % Single-room heat recovery unit Air flow up to 59 CFM Heat recovery efficiency up to 96 % 2018 SINGLE-ROOM HEAT RECOVERY UNITS Features Efficient solution for supply and exhaust ventilation of enclosed

More information

62DA,DB,DC,DD,DE,DF07-38

62DA,DB,DC,DD,DE,DF07-38 62D-3SB 62DA,DB,DC,DD,DE,DF07-38 DEDICATED VERTICAL OR HORIZONTAL 100% OUTDOOR AIR UNIT PERFORMANCE DATA UNIT DIMENSION PRINTS ACCESSORY DIMENSION PRINTS Copyright 2011 Carrier Corporation Syracuse, New

More information

BRAHM. Working together for a crystal-clean production line COLLECTOR SERIES

BRAHM. Working together for a crystal-clean production line COLLECTOR SERIES BRAHM COLLECTOR SERIES Working together for a crystal-clean production line #1 in Welding Smoke, Oil Mist & Oil Smoke Removal Best in Class for Innovative Products and Services SERIES BRAHM by CLEAN AIR

More information

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection Series PIN New Construction or Renovation Application Flexible Quiet Comfort Damage Protection ADIRONDACK AIRE New Construction or Renovation The Adirondack-Aire PIN Series zerozone chassis provides environment

More information

CeilMate TM Series 3 and 4 tons of cooling capacity. Ceiling Mounted Systems. Air Handler with Remote Condensing Unit Air Handler designed for R-410A

CeilMate TM Series 3 and 4 tons of cooling capacity. Ceiling Mounted Systems. Air Handler with Remote Condensing Unit Air Handler designed for R-410A A e r o S y s I n c o r p o r a t e d Ceiling Mounted Systems CeilMate TM Series 3 and 4 tons of cooling capacity Air Handler with Remote Condensing Unit Air Handler designed for R-410A AeroSys, Inc. 929

More information

KHP Models. KHP Series. Heat Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

KHP Models. KHP Series. Heat Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT KHP Series Heat Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT CAUTION - Before installation, careful consideration must be given to how this system will operate if connected

More information

INSTALLATION, OPERATIONS & MAINTENANCE MANUAL HEAT & ENERGY RECOVERY VENTILATORS FOR MODELS: H/E80 H/E130

INSTALLATION, OPERATIONS & MAINTENANCE MANUAL HEAT & ENERGY RECOVERY VENTILATORS FOR MODELS: H/E80 H/E130 Meets Standards: C22.2 no 113 and UL 1812 INSTALLATION, OPERATIONS & MAINTENANCE MANUAL InspirAIR TM Compact HEAT & ENERGY RECOVERY VENTILATORS FOR MODELS: H/E80 H/E130 TO BE COMPLETED BY CONTRACTOR AFTER

More information

WE ARE CONTINUOUSLY ADDING TO AND IMPROVING OUR INDOOR AIR QUALITY PRODUCTS TO PROTECT YOUR FAMILY S HEALTH.

WE ARE CONTINUOUSLY ADDING TO AND IMPROVING OUR INDOOR AIR QUALITY PRODUCTS TO PROTECT YOUR FAMILY S HEALTH. WE ARE CONTINUOUSLY ADDING TO AND IMPROVING OUR INDOOR AIR QUALITY PRODUCTS TO PROTECT YOUR FAMILY S HEALTH. ARE YOU WINNING THE WAR ON INDOOR AIR QUALITY? Are you putting up a fight? Due to the high percentage

More information

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A Upflow/Horizontal 2-Stage, Communicating Speed Gas Furnace XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D1ACV52A TUD2D140ACV52A TDD2B060ACV32A TDD2B080ACV32A TDD2C100ACV52A

More information

Product Data. ERVCCSVB, ERVCCSHB Energy Recovery Ventilators HRVCCSVB, HRVCCSHB Heat Recovery Ventilators

Product Data. ERVCCSVB, ERVCCSHB Energy Recovery Ventilators HRVCCSVB, HRVCCSHB Heat Recovery Ventilators ERVCCSVB, ERVCCSHB Energy Recovery Ventilators HRVCCSVB, HRVCCSHB Heat Recovery Ventilators Product Data Fig. 1 - ERVCCSVB / HRVCCSVB Fig. 2 - ERVCCSHB / HRVCCSHB A05229 A05330 Energy Recovery Ventilation

More information