TECHNICAL DATA SHEET Member of Uponor Group
|
|
- Edward Booth
- 6 years ago
- Views:
Transcription
1 THNIAL ATA SHT Member of Uponor roup Home station WS-1000 WS WS WS WS WS asic unit Hydraulic diagram omestic. TWW hot Wohnung water home. TW vom Strang rinking. HZ-VL-PR water from the line. HZ-RL-PR Heating flow, primary. HZ-VL-SK Heating. HZ-RL-SK return, primary Kabel Heating flow, secondary Heating return, secondary Plattenwärmetauscher 2. Proportionalmengenregler (PM-Regler) 3. Kaltwasserdrosselblende (in Verschraubung) 4. ühlertasche WMZ M10x1, nasstauchend. ntlüftung 7. WMZ-Passstück. Schmutzfänger 10. Zonenventil zur egrenzung Heizvolumenstrom - Wohnung 18. Überwurfmutter 24. Anschluss Potentialausgleich 25. rdung bauseits 1 Plate heat exchanger 2 Proportional quantity controller (PM controller) 3 old water orifice (in screw connection) 4 Sensor pocket heat quantity meter M10x1, wet submerging Ventilation 7 Heat quantity meter adapter irt catcher 10 Zone valve for limiting heating volume flow - home 18 Union nut 24 onnection for potential equalisation 25 arthing provided on site The legends related numbering is not sequential. elta Systemtechnik mbh 1
2 Technical ata Sheet WS-1000 quipment example I A H J Hydraulic diagram 1 I A A. TW Wohnung. TWW Wohnung. TW vom Strang. HZ-VL-PR. HZ-RL-PR. HZ-VL-SK HZ-RL-SK H. WZ I. HZ-VL-Zusatz HK J. HZ-RL-Zusatz HK Kapillarleitung Kabel J 10 H A H I J rinking water home (option) omestic hot water home rinking water from the line Legende: Heating flow, primary HZ-RL-PR Heating flow, secondary Heating return, secondary Process water circulation Heating flow second heating circuit Heating return second heating circuit 1. Plattenwärmetauscher 2. Proportionalmengenregler (PM-Regler) 3. Kaltwasserdrosselblende (in Verschraubung) 4. ühlertasche WMZ M10x1, nasstauchend 5. ntleerung. ntlüftung 7. WMZ-Passstück 8. Passstück 1. Plate Schmutzfänger heat exchanger 210. Zonenventil Proportional zur egrenzung quantity Heizvolumenstrom controller (PM- controller) Wohnung 12. Thermostatisches Temperaturvorhalte-Modul (TTV) 313. Thermostatischer old water orifice Warmwasserbegrenzer (in screw connection) (TW) 415. ifferenzdruckregler Sensor pocket heat primär quantity im Stationseingang meter M10x1, 17. Absperrkugelhahn 1. Pumpe wet submerging 520. mptying Zirkulationspumpe 21. Rückflussverhinderer Ventilation 22. Regelventil für ypassstrecke 723. Heat Thermostatische quantity H-Regelung meter adapter Anschluss Potentialausgleich 8 Adapter 25. rdung bauseits irt catcher 10 Zone valve for limiting heating volume flow - home 12 Thermostatic temperature holding module 13 Thermostatic hot water controller 15 ifferential pressure controller, primary, in the unit inlet 17 Shut-off ball valve 1 Pump 20 irculation pump 21 ackflow preventer 22 ontrol valve for bypass route 23 Thermostatic underfloor heating controller onnection for potential equalisation 25 arthing provided on site 2 elta Systemtechnik mbh
3 Member of Uponor roup Technical data Materials ittings rinking water hygienic suitable materials according VW, UA, WRAS Sanitary: W17N; Heating: W17N, W14N Seal Accordance with the requirements VW KTW 1/2, W270, WRAS Thermal insulation PP Heat exchanger Plates: ; Lot: copper, nickel or screw connection Pipeline Sanitary Max. operating pressure PN 10 Min. pre-pressure 2,0 bar Heating Max. operating pressure PN 10 Max. operating temperature 85 Max. primary controller differential pressure 2,5 bar lectrical Power connection imensions Width x height x depth Weight 230 V/50 Hz with the use of: mixed circuit, Process water circulation, zone valve with room thermostat, otherwise functional without power connection 555 mm x 00 mm x 150 mm WS ,7 kg WS ,2 kg WS , kg WS ,3 kg WS ,8 kg Article no WS WS WS WS WS elta Systemtechnik mbh 3
4 Technical ata Sheet WS-1000 Pressure losses WS ruckverlust Pressure loss bar 0,0 Heizungsseite Heating side (Primär) (primary) Heizwasserbedarf Hot water requirement Liter/h litres/h ruckverlust Pressure loss bar 2,500 2,000 1,500 1,000 0 Kaltwasserseitig old water side (secondary) Sanitär sanitary Sanitär sanitary without orifice with ohne without lende orifice ohne Thermostatic lende mit hot TWR water controller 0 for setting differential für instellung pressure controller iffi ohne without WMZ heat quantity meter unit incl. dirt trap Station inkl. S unit incl. dirt trap Station and differential inkl. S u. pressure iffi-primär controller, primary for setting ifferential pressure controller without heat quantity meter, with thermostatic hot water controller unit incl. dirt trap, differential pressure controller pr, thermostatic hot water controller Installation - at least of one Heat quantity meter: Qn 1.5 further installations e.g. Thermostatic hot water controller, Heat quantity meter, without pressure loss drinking water orifice Pressure losses drinking water orifices (add to the diagram): 12 l/min = bar; 15 l/min = bar; 17 l/min = bar Output curves and return temperatures WS Kaltwassererwärmung old water heating um by 35 K (10-45 ) 50 Kaltwassererwärmung old water heating um by 40 K (10-50 ) Rücklauftemperatur Return temperature Zapfleistung Tap output litre/min Liter/min Tap output litre/min Rücklauftemperatur Return temperature Tap output litre/min 4 elta Systemtechnik mbh
5 Member of Uponor roup Pressure losses WS Heizungsseiter Heating side (primary) (Primär) old Kaltwasserseitig water side (secondary) ruckverlust Pressure loss bar 0,0 Heizwasserbedarf Hot water requirement Liter/h litres/h ruckverlust Pressure loss bar 2,500 2,000 1,500 1,000 0 Sanitär sanitary ohne without lende orifice Maximaler Maximum Sanitär sanitary without orifice with ohne Thermostatic lende mit hot TWR water controller 0 for setting differential für instellung pressure controller iffi ohne without WMZ heat quantity meter unit incl. dirt trap Station inkl. S unit incl. dirt trap Station and differential inkl. S u. pressure iffi-primär controller, primary for setting ifferential für inst. pressure iffi ohne controller WMZ, mit without TWR heat quantity meter, with thermostatic hot water controller Station inkl. S, iffipr, TWR unit incl. dirt trap, differential pressure controller pr, thermostatic hot water controller inbau - mindestens eines WMZ: Qn 1,5 - Installation - at least of one Heat quantity meter: Qn 1.5 weiterer inbauten wie z.. TWR, WMZ etc. sind in der Kurve nicht berücksichtigt.! further installations e.g. Thermostatic hot water controller, Heat quantity meter, without ohne pressure ruckverlust loss drinking TW-lende water orifice Pressure ruckverluste losses TW-lenden drinking water (addieren orifices (add zur to iag.): the diagram): 12 l/min = 0.8 0, ,88 bar; bar; l/min l/min = 0.70 = ,0 bar; 17 bar; l/min 17 = l/min 0.75 = ,75 bar - 0,5 bar Output curves and return temperatures WS Kaltwassererwärmung old water heating by um K (10 K ( ) Kaltwassererwärmung old water heating by um K (10 K ( ) Rücklauftemperatur Return temperature Zapfleistung Tap output litre/min Liter/min 50 Rücklauftemperatur Return temperature elta Systemtechnik mbh 5
6 Technical ata Sheet WS-1000 Pressure losses WS Heating Heizungsseiter side (primary) (Primär) Hot Heizwasserbedarf water requirement litres/h Liter/h 2,500 old Kaltwasserseitig water side (secondary) sanitary sanitary without orifice with Sanitär Sanitär without orifice Thermostatic hot water controller ohne lende ohne lende mit TWR ruckverlust Pressure loss bar bar 0,0 ruckverlust Pressure loss bar 2,000 1,500 1, for setting differential für pressure instellung controller iffi ohne without WMZ heat quantity meter unit incl. dirt trap Station inkl. S unit incl. dirt trap and Station differential inkl. S pressure u. iffi-primär controller, primary für inst. iffi ohne WMZ, mit TWR for setting ifferential pressure controller without heat quantity meter, with thermostatic hot water controller Station inkl. S, iffipr, TWR inbau - mindestens unit incl. dirt trap, eines differential WMZ: pressure Qn 1,5 controller - pr, thermostatic hot water controller Installation weiterer - at inbauten least of one wie Heat z. quantity. TWR, meter: WMZ Qn etc. 1.5 sind in der Kurve nicht berücksichtigt. further installations e.g. Thermostatic hot water controller, Heat quantity meter, without ohne pressure ruckverlust loss drinking TW-lende water orifice Pressure ruckverluste losses TW-lenden drinking water (addieren orifices (add zur iag.): to the diagram): 15 l/min = - 0,0-0,0 bar; bar; l/min l/min = 0,75 = 0,75-0,5-0,5 bar; 1 bar; l/min 1 l/min = 1,00 = - 1,00 1,20 bar - 1,20 bar Output curves and return temperatures WS Kaltwassererwärmung old water heating by um 35 K 35 (10 K ( ) Tap Zapfleistung output litre/min Liter/min Kaltwassererwärmung old water heating by um K (10 K ( ) Zapfleistung Tap output litre/min Liter/min Rücklauftemperatur Return temperature Rücklauftemperatur Return temperature Zapfleistung Tap output litre/min Liter/min elta Systemtechnik mbh
7 Member of Uponor roup Pressure losses WS Heizungsseite Heating side (primary) (Primär) Kaltwasserseitig old water side (secondary) Pressure ruckverlust loss bar 0,0 Heizwasserbedarf Hot water requirement Liter/h litres/h Pressure ruckverlust loss bar 2,50 2,00 1,50 1,00 Sanitär sanitary ohne without lende orifice Sanitär sanitary without orifice with ohne Thermostatic lende mit hot TWR water controller 0 for setting differential für instellung pressure controller iffi ohne without WMZ heat quantity meter unit incl. dirt trap Station inkl. S unit incl. dirt trap Station and differential inkl. S u. pressure iffi-primär controller, primary for setting ifferential für inst. pressure iffi ohne controller WMZ, mit without TWR heat quantity meter, with thermostatic hot water controller Station inkl. S, iffipr, TWR inbau - mindestens unit incl. dirt eines trap, WMZ: differential Qn 1,5 pressure - controller pr, thermostatic hot water controller Installation weitere - inbauten at least of wie one z. Heat. TWR, quantity WMZ, meter: etc. sind Qn in 1.5 der Kurve nicht berücksichtigt. further installations e.g. Thermostatic hot water controller, Heat quantity meter, without ohne pressure ruckverlust loss TW-lende drinking water orifice Pressure ruckverluste losses TW-lenden drinking water (addieren orifices zur (add iag.): to the 12l/min diagram): = 08-0,88 bar; 17 l/min = 0,75-0,5 bar; 1 l/min = 1,00-1,20 bar; 22 l/min = 1,20-1,40 bar bar Output curves and return temperatures WS Kaltwassererwärmung old water heating by um K (10 K ( ) ) 50 Kaltwassererwärmung old water heating by um K (10 K ( ) ) Hot water Heizwasserbedarf requirement Liter/h litres/h Return Rücklauftemperatur temperature Return Rücklauftemperatur temperature elta Systemtechnik mbh Heineckes eld 2227 elle T +4 (5141) (5141) info@deltasystemtechnik.de 7
8 Technical ata Sheet WS-1000 Pressure losses WS ,0 Heizungsseite Heating side (primary) (Primär) Heizwasserbedarf Hot water requirement Liter/h litres/h 2,500 2,000 Kaltwasserseitig old water side (secondary) sanitary Sanitär Sanitär sanitary without orifice with without ohne lende orifice ohne Thermostatic lende mit hot TWR water controller ruckverlust bar ruckverlust bar 1,500 1, for setting differential für instellung pressure controller iffi ohne without WMZ heat quantity meter unit incl. dirt trap Station inkl. S unit incl. dirt trap Station and differential inkl. S u. iffi-primär pressure controller, primary for setting ifferential für inst. pressure iffi ohne controller WMZ, mit without TWR heat quantity meter, with thermostatic hot water controller Station inkl. S, iffipr, TWR unit incl. dirt trap, differential pressure controller pr, thermostatic hot water controller inbau - mindestens eines WMZ: Qn 1,5 - Installation weitere - inbauten at least of wie one z. Heat. TWR, quantity WMZ, etc. meter: sind Qn in 1.5 der Kurve nicht berücksichtigt. further installations e.g. Thermostatic hot water controller, Heat quantity meter, without ohne pressure ruckverlust loss TW-lende drinking water orifice Pressure ruckverluste losses TW-lenden drinking water (addieren orifices zur (add iag.): to the diagram): 1 1 l/min l/min = = 1,00-1,20 bar; l/min = 1,20-1,40 bar Output curves and return temperatures WS Kaltwassererwärmung old water heating by um K (10 K ( ) ) Kaltwassererwärmung old water heating by um K (10 K ( ) ) Heizwasserbedarf Liter/h Return Rücklauftemperatur temperature Hot water requirement litres/h Hot water Heizwasserbedarf requirement litres/h Liter/h Return Rücklauftemperatur temperature elta Systemtechnik mbh We reserve the right to make technical modifications We do not assume any liability for mistakes and printing errors Version: All older versions invalid
TECHNICAL DATA SHEET Member of Uponor Group
TNAL ATA ST Member of Uponor roup ome station WS--4 /L asic unit ydraulic diagram 1 5 4 1 18. TWW Wohnung. TW vom Strang. Z-VL-PR. Z-RL-PR. Z-VL-SK. Z-RL-SK Kabel 1. Plattenwärmetauscher. Proportionalmengenregler
More informationPreconfigured heat interface unit with compact installation depth for preparation of domestic hot water and apartment heating.
T T TACOTHERM DUAL PIKO HEAT INTERFACE UNIT ADVANTAGES Compact installation depth Large number of variants Preconfigured for simple installation On-demand, hygienic preparation of domestic hot water Demand-driven
More informationTA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services
TA-COMFORT-S Prefabricated units Heating interface unit for surface heating and hot water services IMI TA / Prefabricated units / TA-COMFORT-S TA-COMFORT-S All in one design with differential pressure
More informationTA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services
TA-COMFORT-S Prefabricated units Heating interface unit for surface heating and hot water services IMI TA / Control valves / TA-COMFORT-S TA-COMFORT-S All in one design with STAP differential pressure
More informationTACOTHERM FRESH PETA (C/CL)
ACOHERM FRESH PEA (C/CL) FRESH HO WAER SAION WIH HIGH-EFFICIENCY PUMPS Fresh hot water station for hygienically heating drinking water in accordance with the continuous flow principle with and without
More informationDynalux. Floor Heating Manifolds Underfl oor heating circuit manifold
Dynalux Floor Heating Manifolds Underfl oor heating circuit manifold IMI HEIMEIER / Floor Heating Control / Dynalux Dynalux Dynalux adjusts the flow rate in the individual heating circuits directly in
More informationCONNECTION OPTIONS FOR MANIFOLDS & CONTROL UNITS
CONNECTION OPTIONS FOR MANIFOLDS & CONTROL UNITS INSTALLATION INSTRUCTIONS FOR CONTROL BOXES Pay attention to the total pressure loss when connecting UV4- to the control boxes for heating areas > 16 m²!
More informationProductinformatie BAFA.NL BAFA.NL A.U.K. MÜLLER GMBH & CO. KG
Productinformatie A.U.K. MÜLLER GMBH & CO. KG Product Series 1.010.6 A. u. K. Müller Solenoid valves Control valves Special valves and systems A. u. K. Müller GmbH & Co. KG Dresdener Str. 162 D-40595 Düsseldorf/Germany
More informationBrazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)
Data sheet Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 IHPT The XB is a brazed plate heat exchanger designed for use with district heating systems
More informationDynamic thermostatic radiator valves DYNAMICAL
ynamic thermostatic radiator valves YNMIL -----7 series RIT ISO 9 M 6 /7 G unction The YNMIL valve allows the automatic dynamic balancing and pressure-independent adjustment of the thermal medium in the
More informationKitchen Water Dispenser
HOT & COLD WATER DISPENSER Article number: 17861875 Max. flow 2 l/min at 3 bar flow ready-to-use control unit for wall mounting (135 mm x 160 mm x 60 mm) electronic magnetic valve 100-230 V, 50-60 Hz,
More informationInstallation Guide. Circulation set for S-F units. Zirkulationsset für S-F Stationen. Code No. 004U8405
Installation Guide Circulation set for Zirkulationsset für S-F Stationen iv.788 Code No. 004U8400 iv.484 Code No. 004U8403 iv.789 Code No. 004U8401 iv.487 Code No. 004U8405 English - G If the household
More informationHeat Interface Units for decentralised water heating in district heating systems
www.herz.eu Heat Interface Units for decentralised water heating in district heating systems HERZ Heat Interface Units High-quality decentralised water heaters with heating connection, for drinking water
More informationBrazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)
Data sheet Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 IHPT The XB is a brazed plate heat exchanger designed for use with district heating systems
More informationV2075, V2077 Flowshare Valve THERMOSTATIC TWO-WAY FLOWSHARE VALVE
V2075, V2077 Flowshare Valve THERMOSTATIC TWO-WAY FLOWSHARE VALVE Application Thermostatic flowshare valves control the output of radiators in vertical one-pipe heating systems. Heating water not required
More informationThe Meibes concept for the specialist: Easier. Quicker. More successful.
P R I C E L I S T 3 5 V A L I D F R O M 0 1. 0 1. 2 0 1 0...for the professional installer The Meibes concept for the specialist: Easier. Quicker. More successful. Easier Complete pre-assembled modules
More informationAdjustable three-way thermostatic mixing valve... connections ½", ¾", 1" NPT male union and sweat union and ¾" press
MixCal djustable three-way thermostatic mixing valve series CCRIT ISO 9 FM ISO 9 No. CLFFI / N Replaces / N Function The Caleffi MixCal series three-way thermostatic mixing valve is used in systems producing
More informationCALEFFI DISCAL. deaerator-dirt separator DISCAL series ACCREDITED 01123/17 GB. replaces dp 01123/14 GB
ISL deaerator-dirt separator ISL 46-461 series RI ISO 9001 M 2164 LI 01123/17 replaces dp 01123/14 unction eaerators-dirt separators are used to continuously eliminate the air and dirt contained in the
More informationCONTROL UNIT FOR UNDERFLOOR HEATING SYSTEMS
ST.04.04.00 ONTROL UNIT FOR UNERFLOOR HETING SYSTEMS Low temperature control unit Low+high temperature control unit 1. ONTROL UNIT PPLITION The FR control unit is suitable for systems combining both high
More informationTechnical information Installation instructions. Modul-plus (F21-52) High performance calorifiers
Technical information Installation instructions Modul-plus (F21-52) High performance calorifiers These instructions apply to the following types: 5/6-Modul-plus F (21) 5/6-Modul-plus F (31) 5/6-Modul-plus
More information940ESO Tankless Water Heater
ngineering Submittal Sheet Overview and ertifications LOW-L U P US Massachusetts Plumbing oard pproved ngineering Specifications Water heater shall be a Model Therm 940 SO for outdoor installation. Plant
More informationTechnical information for installation and operation
Technical information for installation and operation PR 24002.65 12-04-2016 Subject to technical modifications LogoFresh 100 & 120 fresh water station Electronically controlled GB Meibes System-Technik
More informationMulti Channel Potentiostat for testing the resistance to cathodic disbonding acc. ASTM G-8, ASTM G-42, DIN EN ISO 15711, DIN 30670
Multi Channel Potentiostat for testing the resistance to cathodic disbonding acc. ASTM G-8, ASTM G-42, DIN EN ISO 15711, DIN 30670 Principle of testing cathodic disbonding The CD Test Unit can be used
More informationSolar heating systems
03 energy efficiency Compact, "ALL-IN-ONE" solar system Solar panel for swimming pools Hydraulic components Drain-Unit: dual hydraulic unit with drain back system Drain-Unit: hydraulic unit with drain-back
More informationBrazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)
Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 The XB is a brazed plate heat exchanger designed for use with district heating systems (i.e. air conditioning,
More informationExtreme industrial environments Air/water heat exchangers (roof-mounted, wall-mounted) Recooling system
3 Extreme industrial environments Air/water heat exchangers (roof-mounted, wall-mounted) Recooling system 3 04 eat exchangers One concept, two systems with very different operating methods Air/water heat
More informationMetering systems 0548EN April 2014
08EN April 0 0U8 GEY - Y - Y (GE- series) 900 000/ 00 00A/ 800 00L/ Versions and product codes Product code Type Heat exchanger nominal power GEY, - GEY and production GEY and production Table - Product
More informationTACOTHERM DUAL PIKO MODULAR AND HIGHLY FLEXIBLE HEAT INTERFACE UNITS
TACOTHERM DUAL PIKO MODULAR AND HIGHLY FLEXIBLE HEAT INTERFACE UNITS CUSTOMIZE YOUR INDIVIDUAL STATION The heat interface units in the TacoTherm Dual Piko range adapt perfectly to local conditions. Whether
More information205 Control Installation and Maintenance Instructions
0353143/2 IM-P035-08 CH Issue 2 205 Control Installation and Maintenance Instructions 1. General 2. Installation 3. Temperature ranges 4. Temperature adjustment 5. Maintenance Printed IM-P035-08 in the
More informationHIGH EFFICIENCY CIRCULATORS
HIGH EFFICIENCY CIRCULATORS Heating, Cooling, Solar Thermal and Domestic Hot Water SAVINGS Up to 80% less than traditional pumps TECHNOLOGY Best available technology - PM Motor ENVIRONMENT Environment
More informationSATK 30 heat interface unit
heat interface unit L nt In partnership with: n imensions C C A B B A E Introduction The heat interface unit is the latest intelligent range of HIU from Altecnic. The is the complete solution for instantaneous
More informationInstallation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump
Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Reduced Installation time Precision regulation Minimal tooling required 100% tested prior to packaging High quality
More informationthermostatic valve body with stepless precision presetting
Thermostatic Radiator Valves V-exact II thermostatic valve body with stepless precision presetting Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING AVANTAGE V-exact II
More informationECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION MEGATRON MODEL 10NB-LF 4 HOT & COLD INLETS 4 MIXED OUTLET 2 RETURN PIPING
4 4 5-4 3 8 4 4 5-3 8 4 TERMOSTATI 4 3 4 5-8 4 TERMO STATI TERMOSTATI 4 4 5-3 8 4 4-3 8 4 4 5 OMPLETE WATER TEMPERATURE ONTROL STATION EO-MIX Valve assemblies are ASSE 7 listed Submittal S-596Z-LF August,
More informationInstallation instructions
2Power storage tank Installation instructions This installation construction contains important advice for handling, installing and starting up a 2Power solar plant. Read these advice carefully before
More informationCatalog No. 108-C. Steam Traps
atalog No. 8- Steam Traps Inverted bucket, float and thermostatic, thermostatic and controlled disc steam traps in carbon steel, stainless steel, forged steel and cast iron. ringing Energy own to Earth
More informationultracirc Domestic hot water / Sanitary pumps Instant hot water at every faucet More comfort Saves water and energy
Domestic hot water / Sanitary pumps Instant hot water at every faucet More comfort Saves water and energy extended service life maintenance free without blockage long-lasting, silent operation resistant
More informationTechnote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional.
Page 1 of 5 Application The Single Plate heat interface unit (HIU) for the generation of instantaneous domestic hot water and the direct supply of space heating. This HIU provides hydraulic separation
More informationOil/water cooler - Type TAK/T
1 of 7 - TAK/T The oil/water coolers TAK/T are tube bundle coolers with high efficiency. Table of contents 1 Technical data Advice 4.1 General advice 4. Safety and advice symbols 4.3 General hazard warnings
More informationV-exact II. Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting
V-exact II Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / V-exact II V-exact II V-exact II thermostatic valve
More informationBall Float Steam Trap with Integral Spiratec Sensor and Flanged Connections
Page 1 of TI-P615-03 ST Issue IFT57 SG Iron ISO 9001 Ball Float Steam Trap with Integral Spiratec Sensor and Flanged Connections Cert. No. LRQ 0963008 IFT57H DN0 (horizontal shown) DN15 (vertical shown)
More informationTACOTHERM DUAL DECENTRALISED DOMESTIC HOT WATER TECHNOLOGY
TACOTHERM DUAL DECENTRALISED DOMESTIC HOT WATER TECHNOLOGY WHAT DOES TACONOVA STAND FOR? Taconova Group AG is a well-established Swiss company with over years of experience in providing intelligent building
More informationTechnical Product Guide
FMU - Floor Mixing Unit Boxed set pre-assembled for immediate installation: The FMU Floor Mixing Unit integrates both temperature and flow management, making the single piece unit very easy to install,
More informationunion swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve
VENT APPENDIX A: PIPING SYMBOL LEGEND GENERIC COMPONENTS CALEFFI COMPONENTS circulator circulator w/ ThermoBloc union circulator w/ swing check spring loaded balancing balancing w/ gate check globe s purging
More informationfunction Adjustable thee-way thermostatic mixing valve... connections 1/2", 3/4", 1" NPT male union and sweat union
mixcal adjustable three-way thermostatic mixing valve series CCREITE ISO 9 FM ISO 9 No. CLEFFI / N Replaces / N LOW LE function The Caleffi MixCal three-way thermostatic mixing valve is used in systems
More informationAL-KO HYGRO-OPT MEMBRANE HUMIDIFIER THE NATURAL ROUTE TO AMBIENT HUMIDITY
AL-KO HYGRO-OPT MEMBRANE HUMIDIFIER THE NATURAL ROUTE TO AMBIENT HUMIDITY AL-KO HYGRO-OPT MEMBRANE HUMIDIFIER THE HYGIENIC FORM OF AIR HUMIDIFICATION For a feel-good climate like the one found in the natural
More informationCIRCO 6 Solar Circulation Unit
TECHNICAL INFORMATION / INSTALLATION INSTRUCTIONS CIRCO Solar Circulation Unit CIRCO Solar Circulation Unit in combination with the intelligent SUNGO controllers, it is the safe and reliable heart of a
More informationCalypso TRV-3. (for the Nordic countries) Thermostatic radiator valves With presetting
Calypso TRV-3 (for the Nordic countries) Thermostatic radiator valves With presetting IMI TA / Thermostatic heads and Radiator valves / Calypso TRV-3 (for the Nordic countries) Calypso TRV-3 (for the Nordic
More informationValves, controls + systems Regudis W Dwelling stations
Innovation + Quality Valves, controls + systems Regudis W Dwelling stations Product range Awards: Content 5 6 5 5 3 3 4 7 3 9 6 0 3 8 4 6 4 4 4 3 5 6 7 8 9 0 System illustration Page Content 3 Regudis
More informationFriwa Compact. Operating instructions EN
Operating instructions EN Version 1.1 / Edition 09/2013 Contents 1 Key background information... 3 1.1 Limitation of liability... 3 1.2 Responsibilities of the operator... 3 1.3 Documentation... 3 1.3.1
More informationMultibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off
Multibox 4 Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off IMI HEIMEIER / Floor Heating Control / Multibox 4 Multibox 4 RTL and K-RTL and K-RTL is
More informationSystems for central heating
www.far.eu Highlight Systems and Components for central heating Components for renewable energy systems Pressfar Fittings Presetting valves and thermostatic head Balancing devices Zone valves Metering
More informationComposite under-boiler dirt separator with magnet DIRTMAG
omposite under-boiler dirt separator with magnet IRTMG 55-55 - 55 series 07/7 G REITE ISO 900 FM 65 replaces dp 07/6 G Function The IRTMGSLIM dirt separator separates off the impurities contained in air-conditioning
More informationAkva Vita TDP-F District heating flat station for direct heating and domestic hot water systems
Akva Vita TDP-F District heating flat station for direct heating and domestic hot water systems Akva Vita TDP-F Table of contents Akva Vita TDP-F...1 Table of contents...1 Safety notes...2 Delivery...2
More informationMetering systems 0371EN July 2016 User satellites, GE556 series Versions GE556Y301, GE556Y302
071N July 01 Versions GY01, GY0 igure 1 GY01 GY0 Description The G user satellites are the ideal metering solution in condominium systems with the centralised production of heating water and zone-based
More informationSay heating. Say Herz. HERZ-Supply Engineering
HERZ-Supply Engineering Medium Temperature Control Pressure Control Fittings Control Fittings Lock Shields and Isolators Accessories Spare Parts Say heating. Say Herz. HERZ Valves UK Progress House [ Moorfield
More informationTHERMOSTATIC CONTROL TECHNOLOGY HORNE 40 AND 50 THERMOSTATIC MIXING SYSTEMS
CONTROL TECHNOLOGY 40 AND 50 MIXING SYSTEMS 2 APPLICATIONS CONTROLLING TEMPERATURES IN; > hot water supplies distributed to groups of taps or showers. > domestic hot water supplies from large combination
More informationStandard. Thermostatic Radiator Valves Thermostatic valve body without presetting
Standard Thermostatic Radiator Valves Thermostatic valve body without presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Standard Standard The Standard thermostatic valve bodies are used
More informationSATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production
SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production SATK0 - SATK0 series ACCREDITED ISO 900 FM 009/ GB replaces dp 009/ GB Function The latest generation of Heat Interface
More informationThermoDual Domestic hot water charging system
ThermoDual Domestic hot water charging system Description/Application ThermoDual is the compact and effective domestic hot water (DHW) charging system. Due to the consistent use of carefully selected components
More informationAkva Vita TDP District heating flat station for direct heating and domestic hot water systems
Akva Vita TDP District heating flat station for direct heating and domestic hot water systems Akva Vita TDP Table of contents Akva Vita TDP... 1 Table of contents... 1 Safety notes... 2 Delivery... 2 Transport
More informationInstructions for installation and use Akva Lux II VX substations 1. Contents
Akva Lux II VX thermostatic control Akva Lux II VX thermostatic control, and optional junction box + zone valve Akva Lux II VX (ECL 110) Akva Lux II VX HWP (ECL210) Akva Lux II VX H2WP (ECL 210) 1. Contents
More informationFunction series Thermo-electric actuator electric supply 230 V (ac) or 24 V (ac/dc)
onvertible radiator valve for one-pipe and two-pipe systems series ARIT 0/ G ISO 0 M ISO 0 No. 000 unction The series convertible radiator valve can be used both on one-pipe and two-pipe radiator systems.
More informationStandard. Thermostatic Radiator Valves Thermostatic valve body without presetting
Standard Thermostatic Radiator Valves Thermostatic valve body without presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Standard Standard The Standard thermostatic valve bodies are used
More informationP2050B005, 1/2, Pressure Independent Valve Chrome Plated Brass Ball and Brass Stem, NPT Female Ends
P2050005, 1/2, Pressure Independent Valve hrome Plated rass all and rass Stem, NPT emale nds pplication The Pressure Independent haracterized ontrol Valve is typically used in air handling units on heating
More informationHEAT INTERFACE UNITS (Sanitary Hot Water Only)
HEAT INTERFACE UNITS (Sanitary Hot Water Only) T-FAST i20 (Sanitary Hot Water Only) 20 The T-Fast i20 is an instantaneous domestic hot water production module that produces a flow rate of 20L per/min at
More informationNEW. Thermotank Quadroline. living full of energy. The new generation of plastic storage tanks. Energy systems
NEW Energy systems Thermotank Quadroline The new generation of plastic storage tanks living full of energy Water provides a vital basis for life. It transfers heat in an environmentally friendly way and
More informationStandard. Thermostatic Radiator Valves Thermostatic valve body without presetting
Standard Thermostatic Radiator Valves Thermostatic valve body without presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Standard Standard The Standard thermostatic valve bodies are used
More informationOperating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents
1.0 Table of Contents 1.0 Table of Contents... 1........................................................................ 2 2.0 Functional description... 3 3.0 Safety notes... 4 3.1 Safety Notes general............................................
More informationHeating substations for heat distribution in heating networks and buildings
Heating substations for heat distribution in networks and buildings consumer units pewotherm house substations pewocompact pewov-max PEWO Product Lines District Heating Stations pewocad Heating Circuit
More informationFCHM Hydromatic Pump Control Module
FCHM Hydromatic Pump Control Module Use To maintain and control water pressure, within a pumped system, for the supply to industrial processes and heating systems. Ensures constant flow and pressure to
More informationS and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions
0772150/4 IM-P077-02 ST Issue 4 S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions 1. General safety information 2. General product information 3. Installation 4. Commissioning
More informationRoth fixed-value control set with high-efficiency pump
Energy Systems Roth fixed-value control set with high-efficiency pump Assembly Instructions Living full of energy Contents General information Intended use 3 Benefits 3 Layout/Components 3 Installation/Electrical
More informationData sheet SI 24TE. Brine-to-water heat pump with two performance levels
Data sheet SI 24TE Brine-to-water heat pump with two performance levels Order reference: SI 24TE Installation location: Indoors Flow temperature max 60 C Casing, powder-coated Heat pump for heating purposes
More informationFHM-Cx Mixing Shunts for Floor Heating
FHM-Cx Mixing Shunts for Floor Heating Application Mixing shunt FHM-C5/C6 (UPS pump) The Danfoss compact mixing shunts are used for regulation of flow and supply temperature in hydronic floor heating systems.
More informationPRODUCT INFORMATION. Satellite collector NANOSOL. Solarbayer GmbH (29.14) 1
We develop for your future Solarbayer GmbH (29.14) 1 Safety regulations Carefully read the safety instructions before commencing the installation. It s for your own safety. Please follow the structural
More informationFT14 and FT14HC. SG Iron Ball Float Steam Traps (1" HC, 1¼", 1½" and 2")
Page 1 of TI-S0- ST Issue and HC ISO 9001 SG Iron Ball Float Steam Traps (1" HC, 1¼", 1½" and ") Cert. No. LRQ 09300 HC 1" 1¼" -C 1½" and " Description The and HC are iron bodied ball float steam traps
More informationJRG Fittings/JRGUMAT JRGUMAT JRGUMAT. Thermoblending valve Compact blending water facility with thermal disinfection
JRGUMAT JRGUMAT Thermoblending valve Compact blending water facility with thermal disinfection 3400 3590 3500 3510 JRGUMAT thermoblending valve Advantages supplies blended water of constant temperature
More informationInstallation and operation manual for mixing modules FH-MJB and FH-MJC
40 30 20 50 60 Installation and operation manual for mixing modules FH-MJB and FH-MJC Application The FH-MJB and FH-MJC mixing shunts are designed to supply floor heating areas up to approx. 40 m 2 (from
More informationAkva Lux TDP-F District heating flat station for direct heating and domestic hot water systems
Akva Lux TDP-F District heating flat station for direct heating and domestic hot water systems Akva Lux TDP-F Table of contents Akva Lux TDP-F... 1 Table of contents... 1 Safety notes... 2 Delivery...
More information120D, 150D, 190D, 240D, 370B. How to Order 220V 240V 400V 440V. Note 1) Select one applicable voltage. Voltage. Voltage. Symbol. Model 370B 220V 240V
Refrigerant R7 0, 0 90 I ir compressor Refrigerant 0kW kw 90kW kw Refrigerant R 70 I Refrigerant R7, R Series I Large 0,, 90,, 70 0 90 R7 Size 70 7 9 0 90 Three Voltage 7 9 Voltage 00/00 to 0V (/Hz) 0V
More informationMetering Box METERING AND AMBIENT HEATING FOR HEATING SYSTEM. Overview. Application PRODUCT DATA
Metering Box METERING AND AMBIENT HEATING FOR HEATING SYSTEM Overview PRODUCT DATA The Honeywell Substations series consist of the following products: Metering Box (this datasheet) Heat Interface Unit,
More informationT. +44 (0) E.
Twin Plate Heat interface unit for indirect heating and instantaneous domestic hot water with electronic thermostatic control. Designed for wall-mounting. Application The is the complete solution for hot
More informationMercury Mixing Kit (Code: ME1053)
Mercury Mixing Kit (Code: ME1053) The installation and commissioning of the UFH mixing kit system must be exclusively performed by qualified personnel in accordance with the national guidelines and/or
More informationC B SOLARTHERMAL. Solar thermal systems
66 66 Steca Elektronik GmbH 87700 Memmingen Germany Fon +49 (0) 81 8558-0 Fax +49 (0) 81 8558-12 www.stecasolar.com 67 E A D C B Legend: A Collector B Solar Station C Storage tank D Central-heating boiler
More informationACCREDITED. Product range Code A2L Pre-assembled set point temperature regulating unit with manifolds and box, with UPM3 Auto L pump
Set point temperature regulating unit series ACCREDITED ISO 9 FM / GB replaces dp / GB Function The temperature regulating unit is made to be used in radiant panel systems, in combination with distribution
More informationFHM-Cx Mixing Shunts for Floor Heating
Data Sheet FHM-Cx Mixing Shunts for Floor Heating Application A self-acting proportional regulator is used to regulate the supply temperature. The regulator ensures that the desired supply temperature
More informationModuSat TP. Energy. Heat Interface Units
Energy Twin Plate Heat interface unit for indirect heating and instantaneous domestic hot water with electronic thermostatic control. Designed for wall-mounting. Application The is the complete solution
More informationWZS 82(H)(K)3M 20 I B0W I I I (263) (288) 7.0
WZS 4(H)(K)M WZS 6(H)(K)M WZS 8(H)(K)M WZS (H)(K)M WZS 1(H)(K)M 0 I 60-5 5 B0W65 1 4 I I I -1 50 (58) 178 58 65 50 60 0 I 60-5 5 B0W65 1 4 I I I -1 55 (6) 178 58 65 50 60 0 I 60-5 5 B0W65 1 4 I I I -1
More informationTechnical data. Danfoss DHP-H. Extra and hotter hot water. Extra large integrated hot water tank. Can reduce heating costs by more than 50 percent.
anfoss HP-H xtra and hotter hot water. xtra large integrated hot water tank. an reduce heating costs by more than 50 percent. Main parts.......................................................................
More informationTechnical data DHP-R. A brine-to-water building heat pump in power outputs
brine-to-water building heat pump in power outputs from to 42 kw. illed with R47 (6 ) or 134a (7 ) refrigerant dvanced control with integrated web monitoring Main components...2 Space requirements...3
More informationVentilation unit Zehnder ComfoAir 160
Application The Zehnder ComfoAir 160 comfort ventilation unit was specially developed for use in demanding residential and commercial buildings. It combines maximum comfort, simple operation and a high
More informationTHE REMEHA HIU RANGE Installation, operation and maintenance manual December 2017
Installation, operation and maintenance manual December 2017 CONTENTS The following instructions are for the E70/5, E70/9, T60/5 & T60/7. Introduction... 3 Declaration of conformity... 3 Symbol key...
More informationMarine Grounding System SEK-3. Technical Description Version 1.0 / English
Version.0 / English Updated: November 206 and Accessories To be certified for use in gas hazardous areas of zone according to European Directive EN 204/34/EU (ATEX). The explosion-proof Marine Grounding
More informationCALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function
Thermostatic regulating unit for heating systems 66 series ACCREDITED ISO 9 FM 6 8/7 GB replaces dp 8/ GB Function The thermostatic regulating unit performs the function of keeping the flow temperature
More informationDISCALDIRT deaerator-dirt separator
DISLDIR deaerator-dirt separator 6 series REDIED ISO 900 M 6 ISO 900 No. 000 0/ G replaces dp 0/0 G unction Deaerators-dirt separators are used to continuously eliminate the air and dirt contained in the
More informationEclipse F. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation
Eclipse F Adaptative Flow Control Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Eclipse F Eclipse F The thermostatic
More informationProduct range Code HE1 Connection and energy management compact unit without anti-condensation valve
Connection and energy management compact unit 2850 series ACCREDITED CALEFFI 01259/14 GB ISO 9001 FM 21654 ISO 9001 No. 0003 Function The connection and energy management compact unit enables combining
More informationecocirc E1 Domestic hot water / Sanitary pumps Unequalled economically! Only 8 Watt!
Domestic hot water / Sanitary pumps ecocirc E1 Instant hot water at every tap More comfort Saves water and energy e c o c i r c E 1 Unequalled economically! Only 8 Watt! saves 68% electricity compared
More informationMAKING MODERN LIVING POSSIBLE. Akva Lux II TDP-F. Instructions for installation and use. Danfoss District Energy
MAKING MODERN LIVING POSSIBLE Instructions for installation and use Danfoss District Energy substations Type 004U8264 Type 0048089 Cover for wall-mounting Type 0048044 Cover for recess mounting 1.0 Contents
More information