Energy / Temp / Flow Monitoring with Ultrasonic Flow Meters
|
|
- Charity Bryant
- 6 years ago
- Views:
Transcription
1 Ultrasonic Flow Meters Energy / Temp / Flow Monitoring with Ultrasonic Flow Meters You will be connected to audio using your computer s speakers. Or, you may select Use Telephone after joining the Webinar and call in to listen. Presented by: Brent Baird Instruments Direct Stand By Meeting has not started
2 Ultrasonic Flow Meters Energy / Temp / Flow Monitoring with Ultrasonic Flow Meters You will be connected to audio using your computer s speakers. Or, you may select Use Telephone after joining the Webinar and call in to listen. Meeting in Progress Presented by: Brent Baird Instruments Direct
3 Ultrasonic Flow Meters Presentation Outline: How much water do you use? Why do we need to monitor energy? Theory of ultrasonic technology How do you monitor energy. Technology to monitor energy Best practices in selecting metering technology. Economics
4 Ultrasonic Flow Meters
5 Ultrasonic Flow Meters??? M????
6 Ultrasonic Flow Meters Source: Irrigation, Well water, Desalination, Reservoirs, WTP Residential: Drinking, cleaning, waste, irrigation, heating. Commercial: Drinking, cleaning, waste, irrigation, cooling, heating, process and more. Manufacturing & Process: Cooling, heating, batching, and more WWTP: Waste Treatment And More:
7 Ultrasonic Flow Meters Metering tools to monitor liquid flow and energy Easy to use Budget sensitive Quickly acessable
8 THE SOUND'S TIME OF FLIGHT IS ACCURATELY MEASURED IN BOTH DIRECTIONS AND THE DIFFERENCE IN TIME OF FLIGHT CALCULATED. Ultrasonic Flow Meters
9 Location.. Location Location. 15 Pipe diameters of straight run between elbows for flows of 7 to 10 fps. More for higher flow rates or major obstructions. Less for lower flow rates.
10 Ultrasonic Flow Meters Clamp-on, Portable Basic principles Uses ultrasound waves to measure flow Key advantages Non-invasive No need to shut down system Rental & Purchase Applications Relatively clean cold or hot fluids, pipes must be full No maintenance costs
11 Ultrasonic Flow Meters APPLICATIONS: * Water Monitoring * Energy Management * HVAC * Test & Balance * Chillers * Cooling Towers * Boilers * And More..
12 Building City Water / Influent City Water Meter M Test Meter Flow E-1 Pump
13 Building City Water / Influent City Water Meter M Test Meter Flow E-1 Pump
14 Ultrasonic Flow Meters Building / Campus Mapping: Main Building A Annex Building C Annex Building B In calculating energy use, each building is unique. Address temperature loss or gain when transferring CHWS, CHWR. Meter all flows and temperatures, you cant afford not too
15 Do it right or data will be inaccurate. Flow Meter: Use a meter with a 1% rate accuracy. Less accurate meters or meters with accuracies based on Full Scale can be misleading. Temperature: Temperature differentials can be small (<10 F). For instance, if one sensor reads 1 F high while the other is 1 F low, the energy calculation can be off by 20%. A self-contained Btu meter is recommended as opposed to using separate flow and temperature sensors. Accuracy is generally better (matched sensors) and data collection is simpler, particularly if energy is being metered for revenue purposes.
16 Ultrasonic Flow Meters Using Portable Ultrasonic Meters Discover process. Spot check flows Water usage study Energy usage study Balancing Hydronic system
17 FUJI FSC TRAINING: TEMPERATURE This illustration shows an example of how to mount the RTD sensors.
18 PANAMETRICS PT-878: READING TEMPERATURE Another optional accessory of the PT-878 is the Energy Monitoring RTD Kit. As with the Thickness Gauge, the sensor requires no software or firmware update to use. Installation is simple and involves plug & play with the PT-878.
19 READING TEMPERATURE Location.. Location Location. Mount the RTD temperature sensors in the identical location on the supply and the return (metal) pipes. Failure to-do so will result in temperature differentials that can effect your performance of the BTU calculations
20 FUJI FSC TRAINING: RETRIEVING LOG FILES 1. Remove SD card The SD card is located in the bottom of the meter. Simply open the rubber cover, and push the SD card in and release to eject.
21 Ultrasonic Flow Meters Using Dedicated Ultrasonic Meters Energy monitoring & control by monitoring BTU Flow and temperature Domestic hot & cold water Air conditioning / Heater Available with outputs 4/20mA. Modbus and Communications: 10/100 Base-T, Ethernet, BACnet MSTP, BACnet/IP, Modbus TCP/IP and more..
22 Remote System: Transmit wireless or hard wire to your BAS or we can design a Data Acquisition System for your application Ultrasonic Flow Meters
23 Summary: Ultrasonic Flow Meters Why we need to Monitor Energy Discovery process to establish a baseline Do not make assumptions, collect good data to make good decisions Best practices in selecting metering technology Meter features, economics and availability
24 ABOUT US ULTRASONIC FLOW METER ENGINEERING CO. RENTAL ULTRASONIC METERS SALES, SERVICE, TRAINING, & CALIBRATION FLOW SURVEYS / FIELD SERVICES FLOW METER SYSTEM INTERGRATION PRODUCT DEVELOPMENT & MANUFACTURING..
25 Call us 1(888) Tech Support / Application engineeringor visit us Ph 1(888) on the web support@instrumentsdirect.com * Sales Sales/Customer Support / Order entry * Rental Ph 1(888) sales@instrumentsdirect.com * Supplies * Service Flow Studies, Consulting engineering,* Classroom Training, Speaking * engagements Ph 1(888) info@instrumentsdirect.com Calibration Support
26 QUESTIONS & ANSWERS Brent Baird Application Engr / Technical Speaker Instruments Direct Ph 1(888) sales@instrumentsdirect.com Instruments Direct 2015
27 CRS-401 (2-26 ) CRS-402 ( ) UTXDR-408 (0.5-2 )
Discover how much Water You re Using and Use that Information to Optimize Your Facility
AABC Commissioning Group AIA Provider Number 50111116 Discover how much Water You re Using and Use that Information to Optimize Your Facility Course Number: CXENERGY1704 Brent Baird Instruments Direct
More informationSECTION : CAMPUS CENTRAL METERING SYSTEM DESIGN
Brown University Department of Facilities Management Design & Construction Standards 26 09 01 Campus Central Metering System Design SECTION 26 09 01: CAMPUS CENTRAL METERING SYSTEM DESIGN 1. GENERAL A.
More informationApplications. Features & Benefits ULTRASONIC WATER METER
MEASURE TODAY. ENSURE TOMORROW wprime TM Series 280W-CI Spire Metering offers the latest in Commercial/Industrial ultrasonic metering technology for reliable flow measurement. The rugged 280W-CI water
More informationJune Copyright Climatec
June 2013 Copyright Climatec GUIDLINES FOR CENTRAL PLANT OPTIMIZATION The following document provides guidelines which if followed will maximize the energy savings potential for a central plant available
More informationIntegrated Automation Instrumentation & Terminal Devices
Sections Included In This Standard: 1.1 Building Systems Control 1.2 Building Aumotation Systems (BAS) 1.1 BUILDING SYSTEMS CONTROL A. HVAC CONTROLS: 1. General: Temperature control zones shall not combine
More informationopti-visor ultra-efficient chiller plant automation Typical specification
opti-visor ultra-efficient chiller plant automation Typical File No: 90.893 Date: february 9, 2015 Supersedes: 90.893 Date: april 20, 2012 contents 1.0 Chilled water plant 4 1.1 General system requirements
More informationVirginia Tech Standards for Building Automation System
March 1, 2016 Virginia Tech Standards for Building Automation System A. Existing Conditions: The Campus Building Automation System is Siemens Apogee and controls all significant campus facilties. Virginia
More informationDew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510
Dew point monitoring DS 400 for stationary dew point monitoring of refrigeration or desiccant driers. The touch screen graphic display enables an intuitive operation and shows the progress of the measured
More informationEZ Plate Instantaneous
EZ Plate Instantaneous Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water PVI.com Packaged Instantaneous Domestic Hot Water EZ Plate Instantaneous is a factory-packaged, skid-mounted
More informationTotal Unified Solution for Building Integration: Communications, Access Control, Video Surveillance and Fire
ISC West 2013 Product Showcase Total Unified Solution for Building Integration: Communications, Access Control, Video Surveillance and Fire www.mircomgroup.com [TX3] Unified Solution Our unified solution
More informationDew point set DS 400
set DS 400 Dew point set DS 400 for stationary dew point monitoring of refrigeration or adsorption dryers. The touch screen graphic display enables an intuitive operation and shows the progress of the
More informationPower and Energy Management Solutions
Selection Guide Power and Energy Management Solutions Heating, Ventilating and Air Conditioning (Bulletin 1414) Selection Guide 2 HVAC Selection Guide Instrumentation Selection Checklist Use the following
More informationImportant Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.
1 P age Ezeio v9-120317 Eze Cloud Based Monitoring Systems. Created by Intech Instruments Ltd December 2014 Important Supplementary Manual to the main Ezeio manual. Ezeio Controller and the 2400-A16 input
More informationPackaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water
Packaged Instantaneous Domestic Hot Water Generator Energy Source: Shown with optional boiler water valve and electronic feed-forward control. Operates with low boiler water supply and return temperatures
More informationPURCHASING SECTION th Street, Surrey, B.C. V3S 3C7 Tel: Fax: ADDENDUM NO.
PURCHASING SECTION 6645 148 th Street, Surrey, B.C. V3S 3C7 Tel: 604-590-7274 Fax: 604-599-0956 E-mail: purchasing@surrey.ca ADDENDUM NO. 2 REQUEST FOR QUOTATIONS (RFQ) NO.: 1220-040-2014-001 TITLE: DISTRICT
More informationOctober Airborne & Structure-Borne Ultrasound as a key component to Predictive Maintenance
Airborne & Structure-Borne Ultrasound as a key component to Predictive Maintenance Christopher Hallum, CMRP Regional Manager UK & Ireland UE Systems UK & Ireland ULTRASOUND TECHNOLOGY HOW DOES IT WORK?
More informationCircuit balancing: A key to improving HVAC system operation and control
Circuit balancing: A key to improving HVAC system operation and control David L. Hudson Victaulic Company, Inc. Easton, PA August 2009 As many building superintendents would agree, the symptoms of indoor
More informationAffordable wireless monitoring without compromise
Affordable wireless monitoring without compromise %RH Pa CO 2 Temperature Humidity Door Events Airflow Differential pressure Carbon dioxide www.the-imcgroup.com Notion Pro - Affordability without compromise
More informationCoal Pile Fire Monitoring System
Coal Pile Fire Monitoring System Land Instruments International Over 60 years experience Specialists in Infrared Temperature Measurement Combustion Efficiency & Environmental Emissions Monitoring Joined
More informationCultivator & Hybrid Cultivator
Cultivator & Hybrid Cultivator Precision Temperature & Humidity Packaged Unit INTRODUCTION The Cultivator Series package unit is the industry s MOST ENERGY EFFICIENT and HIGHEST capacity dehumidifier on
More informationMatt Cooper, PE, BEMP, HBDP, Group 14 Engineering Ken Urbanek, PE, HBDP MKK Consulting Engineers, Inc.
M&V Real Results of High Performance Design Matt Cooper, PE, BEMP, HBDP, Group 14 Engineering Ken Urbanek, PE, HBDP MKK Consulting Engineers, Inc. Overview Measurement & Verification (M&V) Plan for New
More informationMultifamily Buildings: Real World Monitored Data on Hot Water Energy and Water Use
Multifamily Buildings: Real World Monitored Data on Hot Water Energy and Water Use BuildingEnergy Boston Conference March 8, 2017 Presented by: Andrew Proulx, P.E., LEED AP Neil Donnelly, E.I.T. New Ecology,
More informationOneWireless. XYR 6000 Series 100 Pressure Transmitters
OneWireless XYR 6000 Series 100 Pressure Transmitters Agenda OneWireless Solution XYR 6000 Series 100 Transmitters Value and Benefits Transmitter Product Comparison Markets and Applications Ordering and
More informationRF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1
RF SCOUT PLUS INSTRUCTION MANUAL Dielectric, LLC 22 Tower Rd. Raymond, ME 04071 Phone: 800.341.9678 www.dielectric.com 21 January 2015, Rev B 1 WARNING Powering RF sensors above +30dBm (1W) will cause
More informationINFRARED HVAC APPLICATION HVAC 101
INFRARED HVAC APPLICATION HVAC 101 John Cannamela Owner ISC Building Diagnostics HVAC Journeyman since 1989 Start up test and Balance since 1992 Level II Thermographer Level II Vibration Level I Eddy current
More informationGuide Specification - MasterFormat 2017 Style SECTION FLOW INSTRUMENTS PART 2 PRODUCTS 2.1 SECTION INCLUDES 2.2 ACCEPTABLE MANUFACTURERS
SECTION 230923.14 FLOW INSTRUMENTS Data contained in this guide specification may be placed in either of the following sections, depending on the specifics of the system design, or incorporated within
More informationSubstation Monitoring System
Substation Monitoring System SF6 Gas Density Monitoring System Description Introduction As a result of recent European legislation on the control of greenhouse gasses, utilities and manufacturers alike
More informationRFP Addendum 2 March 31, 2016
RFP Addendum 2 March 31, 2016 For Best Value Procurement Option Three Security Upgrades Ph 1 UT Health Science Center SBC No. 540/013-04-2015 This Addendum forms a part of the Request for Proposals (RFP)
More informationF-1100 Series Single Turbine Meters Suitable for pipe sizes 1 ¼ and larger.
ONICON Insertion Turbine Flow Meters Provide an accurate, cost effective option for flow measurement of relatively clean liquids such as those found in closed loop HVAC systems. Each meter is built to
More informationClampOn DSP Corrosion- Erosion Monitor
ULTRASONIC INTELLIGENT SENSORS ClampOn DSP Corrosion- Erosion Monitor DIGITAL SIGNAL PROCESSING ULTRASONIC INTELLIGENT SENSORS ClampOn DSP Corrosion-Erosion Monitor The patented ClampOn DSP Corrosion-Erosion
More informationElectric Central Heating Without Pipes! No Boiler - No Pipes - No maintenance. Aluminium Electric Radiators
Electric Central Heating Without Pipes! No Boiler - No Pipes - No maintenance Aluminium Electric Radiators Why Electric Heating? Electric is the fuel of the future for heating requirements. Dwindling supplies
More informationAlpha Engineering Company
+91-8048720989 Alpha Engineering Company https://www.indiamart.com/alphasensors/ We are one of the leading Manufacturer and Supplier of precision Thermocouples & RTD sensors. We provide customized solutions
More informationMEAS SENSOR TAG APP INSTALLATION GUIDE FOR ANDROID
INSTALLATION GUIDE FOR ANDROID This document describes the installation of the Measurement Specialties sensor tag application for Android devices. Contents 1 Installation... 2 1.1 Prerequisite... 22 1.2
More informationTri-Tech Medical Inc.
Submittal Data Sheet Project Information Project Number Approval Features The Tri-Tech Area and Master Alarm Panel digitally displays gas pressure (1 psi increments) monitors and displays normal and alarm
More informationKeeping Chillers Efficient - Archives - Energy and Power Management
Page 1 of 6 Ad Home Subscribe All BNP Media Updates Calendar of Events Columns Features Industry News Keeping Chillers Efficient by Don Clark December 27, 2005 Sensor and Gauge Accuracy Affect Chiller
More informationA. Detail drawing M1 Standard Chilled Water Schematic 1.03 DESCRIPTION OF THE PULLMAN CAMPUS CENTRAL CHILLED WATER LOOP SYSTEM:
33 60 00 PART 1 - GENERAL 1.01 GENERAL REQUIREMENTS A. These standards and procedures apply to the use and interface requirements of the Washington State University Central Chilled Water (CCW) system.
More informationUnion County Vocational - Technical Schools Scotch Plains, New Jersey
SECTION 230593 - TESTING, ADJUSTING, AND BALANCING FOR HVAC PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Balancing Air Systems: a. Constant-volume air systems. b. Variable-air-volume systems. 2.
More informationRLDS - Remote LEAK DETECTION SYSTEM
RLDS - Remote LEAK DETECTION SYSTEM Asel-Tech has spent considerable time and resources over the past 8 years to improve our technology, to the point where it is unparalleled in reliability and performance
More informationAPPLICATION DATA SHEET
APPLICATION DATA SHEET Control Systems Transmitters Sensors Accessories Wall, 19 Rack or Panel Mounting Units 110/230V 50/60Hz AC operation 250 Addressable devices as: Relays, 4-20 Inputs or Gas Detectors
More informationMichigan State University Construction Standards COMMISSIONING OF FIRE ALARM SYSTEMS PAGE
PAGE 280800-1 SECTION 280800 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification
More informationSECTION METERS AND GAGES FOR HVAC PIPING
SECTION 23 0519 METERS AND GAGES FOR HVAC PIPING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Thermometers. 2. Gages. 3. Test plugs. 4. Thermowells. 1.2 SUBMITTALS A. Product Data: For each type
More informationAdvantages. Evaporation Chamber. Evaporate water, not money! No tools required. Limits lifting and simplifies handling
The SKE4 humidifies by converting electricity into heat through a resistive heating element. The element is submerged thus heating up the water in the evaporation chamber to produce steam. The process
More informationNorthwestern University Scope of BAS Contractor
The purpose of this document is to describe the Enterprise Level Server at Northwestern University, and the separation of roles between the System Integrator and the Building Automation System Contractor.
More informationIntroduction Portable Meters Transmitter Probes RELATIVE HUMIDITY
S E C T I O N 10 C O N T E N T S N A V I G A T I O N Introduction.................... 10.2 Portable Meters................. 10.3 Transmitter..................... 10.9 Probes......................... 10.10
More informationControl Systems. Design & Manufacturing. Eco-Friendly. High Performance
Temperature & Humidity Control Systems Design & Manufacturing DX Air / Water / Glycol Cooled Air and Water Side Economizer Chilled Water Systems Eco-Friendly High Performance OPTIMAL COOLING SOLUTIONS
More informationDISTRIBUTION SYSTEMS. Water Piping and Pumps
DISTRIBUTION SYSTEMS Water Piping and Pumps Technical Development Programs (TDP) are modules of technical training on HVAC theory, system design, equipment selection and application topics. They are targeted
More informationecocirc XL HIGH EFFICIENCY LARGE WET ROTOR PUMP FOR HEATING, COOLING AND POTABLE WATER SYSTEMS A-162C
ecocirc XL HIGH EFFICIENCY LARGE WET ROTOR PUMP FOR HEATING, COOLING AND POTABLE WATER SYSTEMS A-162C Exactly what you need in a circulator As the industry leader with more HVAC and plumbing installations
More informationSCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification
February 11, 2019 Master Panel Product Description The Master Panel shall provide lead/lag control and time based, automatic rotation of up to eight (8) boilers, when used in conjunction with LMV3 or LMV5
More informationTemperature Data Logging
. Temperature Data Logging Making the right choice with a Data Acquisition System There are many ways to make temperature measurements. The simplest method is to insert a temperature probe into a device
More informationUltrasonic Clamp-On Flow Meter Testing
Ultrasonic Clamp-On Meter Testing Carried out for Micronics Ltd By Colin Judd Ultrasonic Clamp-On Meter Testing Carried out for: Micronics Ltd Unit B4 Business Centre Davies Way Loudwater High Wycombe
More informationFlexible & Innovative. Cooling Solutions
Flexible & Innovative Cooling Solutions Flexible & Innovative Compu-Aire Inc. offers a variety of high performance precision cooling systems that can adapt to your application needs. With today s rapidly
More informationFor Dealers / Integrators / Architects. IS Series. Video Intercom. Building Communication. Controlling Security.
For Dealers / Integrators / Architects IS Series Video Intercom Building Communication. Controlling Security. IS Series helps save money Control multiple functions from any location to help reduce overall
More informationCRESTRON MEDIAMANAGER INTELLICLASS
CRESTRON MEDIAMANAGER INTELLICLASS Crestron IntelliClass systems provide educators with a simplified yet comprehensive classroom presentation solution that saves time and money. Designed to deliver the
More informationClamp-on ultrasonic flow and energy meters for liquids
Badger Meter Europa GmbH Nürtinger Str. 76 72639 Neuffen (Germany) Tel. +49-7025-9208-0 Fax +49-7025-9208-15 www.badgermeter.de badger@badgermeter.de Model TFX Ultra Clamp-on ultrasonic flow and energy
More informationCONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS
CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS UNDERSTANDING, ACCELERATED TSI SETS THE STANDARD FOR PARTICLE COUNTING Performance Semiconductor, hard disk drive, and flat panel manufacturers
More informationNovember 11, City of Sparks 215 S. 21 st St. Sparks, NV
November 11, 2014 City of Sparks 215 S. 21 st St. Sparks, NV 89432-0857 Attn: Brian Cason Re: Sparks City Hall HVAC Upgrade Project-Alerton Direct Digital HVAC Control System to Match Existing City of
More informationHydronic & HVAC Control Systems
tekmar 218 Full Line Catalog Hydronic & HVAC Control Systems HVAC Multi-Staging Alternative Energy Zoning Snow Melting Setpoint tekmarcontrols.com tekmarcontrols.com Better Design, Better Control, Better
More informationUW Purchase Specification Section Steam Condensate or Hot Water Meter Page 1 of 9
Page 1 of 9 PART 1 GENERAL 1.02 DESCRIPTION A. Purpose 1. This section covers steam condensate meters, steam condensate sub-meters and hot water sub-meters for use in the Owner's steam systems. 1.03 QUALIFICATIONS
More informationSuper WISE. System product for Swegon s system for demand-controlled ventilation
System product for Swegon s system for demand-controlled ventilation Quick facts Pressure optimisation of the supply air and extract air fans Addition and subtraction of flows within a zone Handles 80
More information30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models)
Temperature Control Units Water & Oil - 00 F Portable Chillers Air & Water-Cooled 0-70 F Central Chillers Air & Water-Cooled Packages & Modules 0-70 F Pump Tank Stations Chilled or Tower Water 00-00 gallons
More informationRESISTIVE STEAM HUMIDIFIER
RESISTIVE STEAM HUMIDIFIER The resistive heating elements of the SKE4 convert electrical energy to heat energy that is then transmitted to the surrounding water, raising the temperature to its boiling
More informationBacnet Room Setpoint & Temp Display. Descriptions. Specifications
Descriptions Bacnet Room Setpoint & Temp Display is designed for environment monitoring and controlling in industrial, commercial and other buildings. These transmitters can be used to monitor air temperature
More informationPROCESS CONTROL COURSES
PROCESS CONTROL COURSES To be a world class industrial training provider in Saudi Arabia. To provide world class industrial technical training to prepare a skilled and competent workforce for the hydrocarbon,
More informationEnergy Savings with Direct Digital Control
Energy Savings with Direct Digital Control Energy Solutions Economizers Demand Controlled Ventilation (DCV) Variable frequency drives Programmable thermostats DDC systems small to large 2 Economizers &
More informationSARVEPALLI RADHAKRISHANAN UNIVERSITY, BHOPAL TIME TABLE EXAMINATION JUNE-2018
B.E. II SEMESTER (ALL BRANCH) ( Regular & Ex) Time: - 11:00 AM to 02:00 PM 19/06/2018 20/06/2018 21/06/2018 22/06/2018 23/06/2018 Saturday MA111 Mathematics-II CY110 Chemistry EE110 Basic Electrical &
More informationSentinel: Occupancy Based HVAC Actuation using Existing WiFi Infrastructure within Commercial Buildings
Sentinel: Occupancy Based HVAC Actuation using Existing WiFi Infrastructure within Commercial Buildings Bharathan Balaji, Jian Xu, Anthony Nwokafor, Rajesh Gupta, Yuvraj Agarwal University of California,
More informationLift Station Monitoring & Control The process begins here
Lift Station Monitoring & Control The process begins here Standards Certification Education & Training Publishing Conferences & Exhibits Speakers: Alan Vance E+H Industry Mgr W/WW Terry Sages Rockwell
More informationCHILLED WATER SYSTEM 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS. B. Section HVAC Basic Materials and Methods
230510 CHILLED WATER SYSTEM PART 1: GENERAL 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS A. Section 230000 Basic HVAC Requirements B. Section 230500 HVAC Basic Materials and Methods C. Section
More informationA. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.
15684 ROTARY SCREW WATER CHILLERS ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 236423 An optional
More informationBenefits & Technology for Decentralizing a -40 F Dew Point
Benefits & Technology for Decentralizing a -40 F Dew Point Sponsored by Hank van Ormer, Air Power USA Featured Speaker For your free subscription, please visit http://www.airbestpractices.com/magazine/subscription.
More informationHVAC System Consideration$ 05/14/2012 SAVING MONEY IN HVAC SYSTEMS
SAVING MONEY IN HVAC SYSTEMS Rod Rhoads, GDS Associates Inc HVAC System Consideration$ What percent of a commercial business s energy usage comes from their HVAC system? How much money do commercial facilities
More informationLABORATORY ILLUMINATED FLOTATION BATH
LABORATORY ILLUMINATED FLOTATION BATH MODELS INCLUDE: TFB-1 Thermoline Scientific Equipment Pty. Ltd. ABN 80 000 859 129 10-12 Ross Place Wetherill Park NSW 2164. P.O. Box 6862 Wetherill Park DC NSW 1851
More informationConfined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012
Confined Space Monitoring Leak Investigation 1 Functions 4 Bar Hole Sampling Line Purge Testing Actual Size GX-2012 3 Operating Modes Internal sample draw pump with 50 range Low flow alarm 3 bright visual
More informationMULTI-POINT DENSITY ARRAY FIXED-POINT INTERFACE PROFILING MEASUREMENT
MULTI-POINT DENSITY ARRAY FIXED-POINT INTERFACE PROFILING MEASUREMENT Why Multi-Point DENSITY ARRAY? Leadership in Radiation-Based Measurement Ohmart/VEGA is proud to offer the ultimate in fixed-point
More informationAparajit Instruments.
+91-8048720774 Aparajit Instruments https://www.aparajitinstruments.com/ Manufacturer & Supplier of temperature measuring devices such as thermocouples, bimetal thermometers, thermowells in Overseas Countries.
More informationAre you still stuck with the current status of manual thermometer recording? X Labor Intensive X No History X Inaccurate
Fridge-tag 2 Current Status Are you still stuck with the current status of manual thermometer recording? X Labor Intensive X No History X Inaccurate Future State with The Fridge-tag 2 The future is here
More informationUser Detection Sensors
User Detection Sensors Design Team 5 Kevin Harrison Eric Hosey Leslie Hodges Nathan Kelly Berna Saracoglu Agenda Sensing Technologies Infrared Ultrasonic Capacitive Pressure Video Image Key Points Theory
More informationBuildingautomation with BACnet Too extensive for small Airports?
RELIABLE BUILDING OPERATION AT AIRPORTS Gateway Gardens at Frankfurt Airport Sept 27-28, 2018 Buildingautomation with BACnet Too extensive for small Airports? Dipl. Ing (FH) Thomas Harrer Flughafen Nürnberg
More informationWiFi Hints & Tips. Contents. WiFi Hints and Tips 1. Page No. Section No. Title
WiFi Hints & Tips Contents Page No. Section No. Title Section.0 System Set-Up 3 Section. Sensor Set-Up 4-5 Section. Sensor Set-Up (Configuring Network) 6-9 Section.3 Sensor Set-Up (Configuring Settings)
More informationThe latest development in material characterization and polymer processing. Rheometer Services Inc.
The latest development in material characterization and polymer processing Rheometer Services Inc. rs5000-s1 Polymer Prep Station New solutions for material characterization and polymer processing rs5000
More informationAir Conditioning Technology
Air Conditioning Technology Degrees: AAS Air Conditioning Technology 60-66 Diploma Heating, Ventilation, and Air Conditioning Mechanic 47-55 Certificate Environmental Control System Servicer 25-26 Environmental
More informationSubstation Monitoring System
Substation Monitoring System UHF Partial Discharge Monitoring System Description Introduction The UHF PDM System is the third generation, spanning 20 years, of monitoring systems developed for GIS partial
More informationDIVISION 26 ELECTRICAL SECTION LIGHTING CONTROL SYSTEM
DIVISION 26 ELECTRICAL SECTION 26 09 26 PART 1 GENERAL 1.01 DESCRIPTION A. The intent of this set of specifications is to provide a complete, functional, intelligent, lowvoltage lighting control system
More informationThe product segments Heating, ventilation, air conditioning. Control Products & Systems OEM.
The product segments Heating, ventilation, air conditioning Control Products & Systems OEM www.siemens.com/buildingtechnologies-oem The right product for every application Siemens specializes in the development,
More informationNiagara4 Technical Certification Program Student Guide DAY 1 DAY 2
Niagara4 Technical Certification Program Student Guide DAY 1 Welcome Course Introduction Platforms & Stations Niagara4 Fundamentals Simple Logic: Hot Water Pump Control (Thermostatic) Simple Logic: Hot
More informationFACILITY CONTROLS BUILDING AUTOMATION SYSTEM (BAS) DESIGN AND CONSTRUCTION STANDARD
PART 1: GENERAL 1.01 Purpose: A. The design guidelines contained herein include the requirements for integrated automation facility controls at The University of Texas at Austin. It is the intention of
More informationAPPLICATION DATA SHEET
APPLICATION DATA SHEET Wed : www.saenchotesei.com WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 920 - Wall, 19 Rack or Panel Mounting Units - 110/230V 50/60Hz AC operation - 250 Addressable
More informationPreparing the Next Generation of Building Technicians
Preparing the Next Generation of Building Technicians Laney's Model for Advanced Curriculum and Laboratory Requirements In some cases defining the new technician Green Collar Job Training at Laney College
More informationMaster devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems
X X testregistrierung Type Web server, also for mobile devices Zone modules Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems X-AIRCONTROL zone
More informationProduct Catalogue. Complete Wireless Sensor Solutions SYSTEMS. 100% Peace of Mind! WEB ID WEB ID WEB ID
Product Catalogue Complete Wireless Sensor Solutions WEB ID WEB ID WEB ID SYSTEMS WEB ID WEB ID INDEX Section 2) - Gateways & Software Section 3) - Coin Cell Temperature Sensors Section 4) - Humidity Sensors
More informationElectric dynamic storage radiators German Technology and Engineering at its very best!
DYNAMIC STORAGE RADIATORS Authorised Distributors and Installers. Electric dynamic storage radiators German Technology and Engineering at its very best! Why Electric Heating? Electric is the fuel of the
More informationFITOCLIMA 600 & 1200 STABILITY
STABILITY AND PHOTOSTABILITY TESTING FITOCLIMA 600 & 1200 STABILITY STABILITY STORAGE AND PHOTOSTABILITY TESTING CHAMBERS ICH, GMP, WHO, FDA COMPLIANT Common applications include: Pharmaceuticals Cosmetics
More informationCompressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture
meas. according to ISO 8573 Residual oil content - particles - moisture DS 500 - the intelligent chart recorder of the next generation. The centerpiece of compressed air quality measurement is the chart
More informationENGINEERED SYSTEMS CUSTOM DESIGNED AND BUILT DESIGNED FOR YOU CAPABILITIES IDENTIFYING YOUR NEEDS COMMISSIONING YOUR SYSTEM
CUSTOM DESIGNED AND BUILT ENGINEERED SYSTEMS CAPABILITIES Hydronic Systems (Condensing or Non-Condensing) Steam Systems (Low or High Pressure, Clean Steam) Thermal Fluid Systems (Hot Oil Systems) Thermal
More informationTRIDENT GS SERIES Central Chiller
Blending Conveying Drying Process Cooling Heat Transfer Size Reduction TRIDENT GS SERIES Central Chiller Compact Innovative Scalable Innovative and compact designs with 50 to 120 individual circuit chilling
More informationTemperature Solutions Line Card
Solutions September 2015 We re Your One Stop Temp Shop One simple model number is all it takes to order our complete, Ready-to-Install Assemblies. They include your choice of: Universal PC-Programmable,
More informationSan Antonio Water System Purchasing Division Commodity Assignments
San Antonio Water System Purchasing Division Commodity Assignments Richard A. Marsh (210) 233-3412, Richard.Marsh@saws.org Analyzers Backfill Material Billing Envelopes Biomonitor Analysis Calibration
More informationLeak Detection and Water Loss Control. Maine Water Utilities September 9, 2010
Leak Detection and Water Loss Control Maine Water Utilities September 9, 2010 Leak Detection and Water Loss Control Utilities can no longer tolerate inefficiencies in water distribution systems and the
More informationPROJ. NO SECTION METERS AND GAGES FOR HVAC PIPING
SECTION 23 05 19 METERS AND GAGES FOR HVAC PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationSteam Trap Inspection Methods And Steam Cost Analysis
Steam Trap Inspection Methods And Steam Cost Analysis 14 Hayes Street, Elmsford NY 10523-2536 USA Tel: 914-592-1220 Toll Free USA & Canada 24 Hour Fax Email: Internet 800-223-1325 914-347-2181 info@uesystems.com
More information