HYDRAULIC SEPARATION. Product Range

Size: px
Start display at page:

Download "HYDRAULIC SEPARATION. Product Range"

Transcription

1 YDRAULIC SEPARAON Inta s ydraulic separator provides an effective means of separation between the boiler and load circuits preventing interference between simultaneously operating circulators and providing improved efficiency in the system. The hydraulic separator also conveniently provides air and dirt separation as a complete module unit. Inta s hydraulic separator is also the ideal way to interface multiple loads to a multiple boiler system. Actively de-aerates fluid system Automatically discharges air build up Improves efficiency ydraulic, air and dirt separation Available in a range of sizes Isolation valve for discharge of dirt and to connect auxiliary components Eliminates the need for a primary loop circulator, which reduces system installation and operating cost Product Range Description Code List Code Price (exc VAT) ydraulic Separator 1" FxF connection SY0617 ydraulic Separator 1 1/4" FxF connection SY ydraulic Separator 1 1/2" FxF connection SY ydraulic Separator 2" FxF connection SY ydraulic Separator 50 connection SY ydraulic Separator 65 connection SY ydraulic Separator 80 connection SY ydraulic Separator connection SY0617

2 YDRAULIC SEPARAON Technical Specification ax working pressure Body separator Ball valve Air separator 10 Bar 25 Bar 8 Bar C Operating temperature range Dimensions weight 3/4"F 3/4" 20 3/4"F ITALY CW617N PN Dimension mm mm 3/4" 3/4" /4" 3/4" /4" 3/4" /4" 3/4" weight kg mm kg mm 663 2, , mm mm Dimension 1" 50 1/2" 3/4" 1"1/4 65 1/2" 3/4" 1"1/2 80 1/2" 3/4" 2" 1/2" 3/4"

3 YDRAULIC SEPARAON Flow rate and pressure drop m3/h 14,7 O) 1"1/4 3,1 26,5 1"1/2 4,2 35,3 2" 7,1 Pressure Drop 0.1 bar (1kPa =102 mm 1" flow max m3/h 1,8 2 Size , ,8, ,8 156,6 42,2 264, /2 1 1/4 1 0,1 0,01 0,1 1,0 10,0,0 0,0 Flow rate m3/h Size 1" 1"1/4 1"1/2 2" ax range l/h Kvs (1) wieght m3/h 14,7 26,5 35,3,3 156,6 264,3 kg 2,5 3, Kvs hydraulic content ltr 1,1 2,

4 YDRAULIC SEPARAON Applications ydraulic separator used as a circuit breaker between the riser and the hydraulic load of independent heating zones. This solution allows the secondary circuit, feeding the riser, not to be hydraulically influenced by the operation of the thermal zones. 3/4" 20 ITALY CW617N PN40 Example of an application of the hydraulic separator used as a circuit breaker between the primary circuit and the secondary circuit of distribution. With loads powered from its pumps (for example; circuits with high pressure drops) the hydraulic separator is used as a circuit breaker to the secondary circuit. FE FE FE

5 YDRAULIC SEPARAON Operating principles hydraulic separator used as a circuit breaker between the circuit for heat production and the distribution circuit to users. Typical solution to be used for in plant rooms using two tubes for the air conditioning of offices or buildings. This solution enables the primary hot circuit to be hydraulically independent of the utilities (the primary circuit is rendered cold independent of the buffer tank). The prevalence of circuit pumps ensures only the secondary circulation of the thermal fluid to the appropriate feed C C PS C TS A PS C TS 3/4" 20 A FS ITALY CW617N PN40

6 YDRAULIC SEPARAON Operating principles Example of a hydraulic separator being used as a circuit breaker between a primary boiler circuit and a secondary heat distribution circuit in a dwelling with two thermal zones This is a typical solution used when the performance of the boiler pump is insufficient to ensure the correct supply of all terminal equipment. FE This solution: - Prevents unnecessary access to the boiler for replacement circulator pump - Avoids the necessity of a second circulator pump in series ensuring correct feed to terminal fittings and prevents reaching abnormal and dangerous circulation within the boiler over the values permitted by the manufacturer. FE E&OE 10/2012

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB 4 RESET ON DHW CH FAULT SATK wall-mounted heat interface unit Fitted for connection to DHW storage SATK4 series ACCREDITED CALEFFI 6/4 GB ISO 9 FM 64 ISO 9 No. The latest generation of heat interface units

More information

SATK 30 heat interface unit

SATK 30 heat interface unit heat interface unit L nt In partnership with: n imensions C C A B B A E Introduction The heat interface unit is the latest intelligent range of HIU from Altecnic. The is the complete solution for instantaneous

More information

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services TA-COMFORT-S Prefabricated units Heating interface unit for surface heating and hot water services IMI TA / Control valves / TA-COMFORT-S TA-COMFORT-S All in one design with STAP differential pressure

More information

Metering systems 0548EN April 2014

Metering systems 0548EN April 2014 08EN April 0 0U8 GEY - Y - Y (GE- series) 900 000/ 00 00A/ 800 00L/ Versions and product codes Product code Type Heat exchanger nominal power GEY, - GEY and production GEY and production Table - Product

More information

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features Comfort Module Range for Monobloc Heat Pumps Quality Management Systems Comfort module with two-zone kit Single-zone comfort module 8HMA Nominal heating capacity 4- kw Nominal cooling capacity 4- kw The

More information

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control. product selection data Compact comfort module DHW management possibility Multi zone option control Easy installation Comfort module with two-zone kit Single-zone comfort module Comfort Module Range for

More information

Systems for central heating

Systems for central heating www.far.eu Highlight Systems and Components for central heating Components for renewable energy systems Pressfar Fittings Presetting valves and thermostatic head Balancing devices Zone valves Metering

More information

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT DOC1066 GB STOKVIS ENERGY SYSTEMS 96R WALTON ROAD EAST MOLESEY SURREY KT8 0DL TEL: 08707 707 747 FAX: 08707 707 767 E-MAIL:info@stokvisboilers.com

More information

RADIANT PANEL SYSTEM CONTROL QUICK GUIDE

RADIANT PANEL SYSTEM CONTROL QUICK GUIDE RADIANT PANEL CONTROL QUICK GUIDE 05 RADIANT PANEL CONTROL Terms and definitions The system temperature regulation can be carried out in only two basic ways: Flow rate control of the medium feeding the

More information

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve Connection and energy management compact unit 2850 series ACCREDITED CALEFFI 01259/14 GB ISO 9001 FM 21654 ISO 9001 No. 0003 Function The connection and energy management compact unit enables combining

More information

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function Thermostatic regulating unit for heating systems 66 series ACCREDITED ISO 9 FM 6 8/7 GB replaces dp 8/ GB Function The thermostatic regulating unit performs the function of keeping the flow temperature

More information

AVTI Multifunctional self - acting controller

AVTI Multifunctional self - acting controller AVTI Multifunctional self - acting controller Description / Application AVTI is a self - acting combined controller developed for controlling small heat units with a room heating system and a hot service

More information

HEAT INTERFACE UNITS (Sanitary Hot Water Only)

HEAT INTERFACE UNITS (Sanitary Hot Water Only) HEAT INTERFACE UNITS (Sanitary Hot Water Only) T-FAST i20 (Sanitary Hot Water Only) 20 The T-Fast i20 is an instantaneous domestic hot water production module that produces a flow rate of 20L per/min at

More information

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production SATK0 - SATK0 series ACCREDITED ISO 900 FM 009/ GB replaces dp 009/ GB Function The latest generation of Heat Interface

More information

PROPAK THERMAL. Packaged Plate Heat Exchanger

PROPAK THERMAL. Packaged Plate Heat Exchanger PROPAK THERMAL Packaged Plate Heat Exchanger 2 PROPAK THERMAL Applications Care Homes Student Accommodation Sports & Leisure Hotels Restaurants Accommodation Accommodation Sport & Leisure Care Homes PROPAK

More information

Stokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing

Stokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing Stokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing Water Heater Supplement STOKVIS ENERGY SYSTEMS 96R Walton Road East Molesey Surrey KT8 0DL Tel: 020 8783 3050 / 0870 7707747 Fax: 020

More information

Dirt and Air Separators

Dirt and Air Separators CX Dirt and Air Separators CX Product Overview Dutypoint CX The Dutypoint CX range of separators are designed to automatically remove dirt and air from heating, cooling and process systems, ensuring optimum

More information

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Reduced Installation time Precision regulation Minimal tooling required 100% tested prior to packaging High quality

More information

heat interface units A BOILER WITHOUT A FLAME HIU Single PHE options

heat interface units A BOILER WITHOUT A FLAME HIU Single PHE options A BOILER WITHOUT A FLAME HIU Single PHE options heat interface units Communal Heat Networks A central boiler house will generate heat which is distributed through a network of pipe to each home or apartment

More information

Herz York Direct Heat Interface Unit

Herz York Direct Heat Interface Unit www.herzvalves.com Herz York Direct Heat Interface Unit The Modern Solution for Apartment Heating and Domestic Hot Water Services General Description The Herz York Direct HIU is suitable for all community

More information

Mercury Mixing Kit (Code: ME1053)

Mercury Mixing Kit (Code: ME1053) Mercury Mixing Kit (Code: ME1053) The installation and commissioning of the UFH mixing kit system must be exclusively performed by qualified personnel in accordance with the national guidelines and/or

More information

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE SPECIFICATIONS... 1 OVERVIEW... 2 PRECAUTIONS... 2 MOUNTING LOCATION... 2 CONNECTION TO BOILER PRIMARY PIPING:... 3 ELECTRICAL CONNECTION... 4 FLUSHING THE

More information

CALEFFI. Anti-condensation circulation unit. 282 series 01225/14 GB. replaces dp 01225/11. Code completion Setting 45 C 55 C 60 C 70 C.

CALEFFI. Anti-condensation circulation unit. 282 series 01225/14 GB. replaces dp 01225/11. Code completion Setting 45 C 55 C 60 C 70 C. Anti-condensation circulation unit 8 series ACCREDITED ISO 9 F 654 ISO 9 No. CALEFFI 5/4 GB replaces dp 5/ Function The anti-condensation circulation unit performs the function of connecting the solid

More information

Heat Transfer Packages

Heat Transfer Packages Heat Transfer Packages Heat Transfer Package (HTP Series) Building Heat, Process Heat, Swimming Pool Heater, Cooling Applications and Snow Melt Package (SMP Series) Steam,, High Temperature Hot Water,

More information

Installation and operation manual for mixing modules FH-MJB and FH-MJC

Installation and operation manual for mixing modules FH-MJB and FH-MJC 40 30 20 50 60 Installation and operation manual for mixing modules FH-MJB and FH-MJC Application The FH-MJB and FH-MJC mixing shunts are designed to supply floor heating areas up to approx. 40 m 2 (from

More information

AIRTERM DIRT AND AIRTERM MAG COMBINED SELF-CLEANING DIRT SEPARATORS / DEAERATORS

AIRTERM DIRT AND AIRTERM MAG COMBINED SELF-CLEANING DIRT SEPARATORS / DEAERATORS AIRTERM DIRT AND AIRTERM MAG COMBINED SELF-CLEANING DIRT SEPARATORS / DEAERATORS CT2831.0_00 EN April 2015 * Airterm Dirt Airterm Mag * o Removes any impurity o Self-cleaning o Ensures system efficiency

More information

DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe

DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe Copyright 206 Caleffi NA0322.02 www.caleffi.com NA5453 Series Installation, commissioning and servicing instructions Function

More information

Installation, commissioning and servicing instructions

Installation, commissioning and servicing instructions NA10322.01 www.caleffi.com DIRTMAG dirt separator Copyright 2015 Caleffi NA5453 Series Installation, commissioning and servicing instructions Function In heating and chilled water systems, the circulation

More information

INSTALLATION AND SERVICING

INSTALLATION AND SERVICING INSTALLATION AND SERVICING LOGIC HIU (Heat Interface Unit) Indirect 75 Indirect 50 Direct MT Direct HT When replacing any part on this appliance, use only spare parts that you can be assured conform to

More information

Heat Link MECHANICAL ROOM IN A BOX. SSP Series SS Manifold Pump Panel Installation, Operation, and Maintenance Manual. L6SSPxx000x SSPLR106T SSPSS106B

Heat Link MECHANICAL ROOM IN A BOX. SSP Series SS Manifold Pump Panel Installation, Operation, and Maintenance Manual. L6SSPxx000x SSPLR106T SSPSS106B SSP Series SS Manifold Pump Panel Manual GROUND LIVE NEUTRAL CAUTION 5 VOLTS ONLY 0 80 00 00 C F 80 60 40 60 0 0 40 40 60 80 00 SSPLR06T GROUND LIVE NEUTRAL CAUTION 5 VOLTS ONLY 0 80 00 00 C F 80 60 40

More information

Chiller Plant Design. Julian R. de Bullet President debullet Consulting

Chiller Plant Design. Julian R. de Bullet President debullet Consulting Chiller Plant Design Julian R. de Bullet President debullet Consulting 703-483-0179 julian@debullet.com This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer ASHRAE

More information

LEP kw. Indoor monobloc water-water unit. Total heat recovery multi-purpose units LEP PLUS

LEP kw. Indoor monobloc water-water unit. Total heat recovery multi-purpose units LEP PLUS Total heat recovery multi-purpose units LEP Indoor monobloc water-water unit LEP 50-40 kw Maximum efficiency with total recovery and dissipation in water. Total heat recovery multi-purpose unit Multi-purpose

More information

PRESSURE INDEPENDENT CONTROL VALVE TECHNOLOGY. 3/16/2012 Fred Ferrara 1

PRESSURE INDEPENDENT CONTROL VALVE TECHNOLOGY. 3/16/2012 Fred Ferrara 1 PRESSURE INDEPENDENT CONTROL VALVE TECHNOLOGY 3/16/2012 Fred Ferrara 1 Typical Hydronic System Problems Low Delta T s resulting in: 1. Chillers operating at higher capacities and/or longer than necessary

More information

HYDRONIC SPECIALTIES TACO MPT Tank(s) 05/30/2012. A. Multi-Purpose Tank buffer tank, air separator, and hydraulic decoupler

HYDRONIC SPECIALTIES TACO MPT Tank(s) 05/30/2012. A. Multi-Purpose Tank buffer tank, air separator, and hydraulic decoupler SECTION 15181 - HYDRONIC SPECIALTIES PART 1 - GENERAL 1.1 SECTION INCLUDES A. Multi-Purpose Tank buffer tank, air separator, and hydraulic decoupler B. Expansion tanks C. Pump accessories 1.2 RELATED SECTIONS

More information

UNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2. Version: 2018_07_19_v2.2

UNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2. Version: 2018_07_19_v2.2 UNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2 Version: 2018_07_19_v2.2 Abstract This is a quick reference guide for selecting the UniQ range of heat batteries for the required application. For designing a

More information

RTA TECHNICAL MANUAL AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION O L S E A F RA N

RTA TECHNICAL MANUAL AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION O L S E A F RA N A RE F S E -FRIEND Y R E IG RA N T G AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION O L RTA C TECHNICAL MANUAL 1 2 SUMMARY THIS MANUAL IS DIVIDED INTO SECTIONS. THEIR NAMES APPEAR IN THE HEADING

More information

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS Energy saving thanks to a total recovery p Cooling Heating/DHW h Galletti multi-purpose heat pumps are total recovery units used for a simultaneous hot and

More information

CALEFFI. Modulating temperature regulating unit for heating and cooling with high temperature distribution kit. series /04 GB.

CALEFFI. Modulating temperature regulating unit for heating and cooling with high temperature distribution kit. series /04 GB. Modulating temperature regulating unit for heating and cooling with high temperature distribution kit series cert. n ISO / GB Function The modulating temperature regulating unit with high temperature distribution

More information

Installation and Service Instructions SM1 SOLAR CONTROL MODULE IMPORTANT. Read and save these instructions for future reference.

Installation and Service Instructions SM1 SOLAR CONTROL MODULE IMPORTANT. Read and save these instructions for future reference. Installation and Service Instructions for use by heating contractor Solar Control Module for solar connections to the Vitotronic control SM1 SOLAR CONTROL MODULE Product may not be exactly as shown IMPORTANT

More information

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES FUNCTION Thermostatic expansion valves are used to regulate and cut-off the flow of the heat transfer fluid that circulates inside airconditioning system terminals (radiators, fan coils, etc.). Thermostat

More information

The Ultimate in Distribution Efficiency. Air Eliminator Dirt Separator Low Loss Header Hydraulic Separator

The Ultimate in Distribution Efficiency. Air Eliminator Dirt Separator Low Loss Header Hydraulic Separator The Ultimate in Distribution Efficiency Air Eliminator Dirt Separator Low Loss Header Hydraulic Separator Air- and dirt-free system water through a single unit, plus hydraulic separation in a low loss

More information

R557R EN January 2012

R557R EN January 2012 R7R- 077EN January 0 07U 00 00 00 WITH HIGH TEMPERATURE MANIFOLDS Example: R7RY0 + RAY00 R7R- WITH THERMAL ENERGY METERING Description R7R- group is used for the regulation of the fixed point heating for

More information

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional.

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional. Page 1 of 5 Application The Single Plate heat interface unit (HIU) for the generation of instantaneous domestic hot water and the direct supply of space heating. This HIU provides hydraulic separation

More information

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 The XB is a brazed plate heat exchanger designed for use with district heating systems (i.e. air conditioning,

More information

CALEFFI. Anti-condensation recirculation and distribution unit. 281 series 01224/14 GB. Replaces dp 01224/12 GB. Function

CALEFFI. Anti-condensation recirculation and distribution unit. 281 series 01224/14 GB. Replaces dp 01224/12 GB. Function Anti-condensation recirculation and distribution unit 8 series ACCREDITED ISO 900 FM 654 ISO 900 No. 000 CALEFFI 04/4 GB Replaces dp 04/ GB GB Function The anti-condensation recirculation and distribution

More information

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique

More information

DISCALDIRT deaerator-dirt separator

DISCALDIRT deaerator-dirt separator DISLDIR deaerator-dirt separator 6 series REDIED ISO 900 M 6 ISO 900 No. 000 0/ G replaces dp 0/0 G unction Deaerators-dirt separators are used to continuously eliminate the air and dirt contained in the

More information

Cold from Heat Product Catalogue 2010

Cold from Heat Product Catalogue 2010 Cold from Heat Product Catalogue 2010 Adsorption Chillers Re-coolers Pump Stations Accessories Complete System of Thermal Cooling Introduction The complete system for ACS operation is comprised of three

More information

APPLICATIONS. For the accelerated circulation of hot water in heating circuits with duty point optimisation

APPLICATIONS. For the accelerated circulation of hot water in heating circuits with duty point optimisation OPERATING RANGE Flow rate of up to m /h Manometric head of up to m Max. operating pressure bar Min. intake pressure, bar at 9 C Water temperature range + at + C * EEI-Part, * for a ambient temperature

More information

HEAT EXCHANGER FORMULAS & EXAMPLE

HEAT EXCHANGER FORMULAS & EXAMPLE Formulas for Heat Exchanger System using a Modulating Control Valve Definition of Terms and Units: E = Mean Heat Transfer Rate or Heat Load (Btu/hr) E D = Design Heat Load (Btu/hr) U = Overall Heat Transfer

More information

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW Stainless steel range of condensing boilers Outputs from 50kW to 660kW Designed to meet carbon reduction targets Lifetime service and support Totally dependable. page 1 www.pottertoncommercial.co.uk Contents

More information

BOILER APPLICATION GUIDE for:

BOILER APPLICATION GUIDE for: T MFC Series Boiler Application Guide GF-148-B TECHNICAL APPLICATION GUIDE BOILER APPLICATION GUIDE for: Piping and Controls, Water Quality, and Single/Multi Installations Applies to MFC Series Models:

More information

Pivot Stove Hydronic Installation Guide

Pivot Stove Hydronic Installation Guide Pivot Stove Hydronic Installation Guide Install Location When installing the header tank - install directly above the appliance. There needs to be a continual rise between the appliance and the header

More information

Broag Pressurisation equipment

Broag Pressurisation equipment Broag Pressurisation equipment Compact wall mounted and free standing pressurisation units, utilising the latest microprocessor control. For use on sealed heating and cooling systems, offering accurate

More information

STOKVIS R40 EVOLUTION RANGE. High Efficiency Fully Condensing Ultra Low NOx Wall Mounted Gas Fired Boilers

STOKVIS R40 EVOLUTION RANGE. High Efficiency Fully Condensing Ultra Low NOx Wall Mounted Gas Fired Boilers STOKVIS R40 EVOLUTION RANGE High Efficiency Fully Condensing Ultra Low NOx Wall Mounted Gas Fired Boilers R40 EVOLUTION RANGE High Efficiency - Fully Condensing - Ultra Low NOx Wall Mounted Gas Fired Boilers

More information

Daikin Altherma/Viessmann Integration Notes (used with schematics M1 thru M5)

Daikin Altherma/Viessmann Integration Notes (used with schematics M1 thru M5) March 15, 2011 Daikin Altherma/Viessmann Integration Notes (used with schematics M1 thru M5) Our Daikin Altherma project involves integrating an indoor unit (EKHBX054BA3VJU) with an existing domestic hot

More information

FRISTAR Fresh water station

FRISTAR Fresh water station FRISTAR Version 2.02 EN Manual version 2 Fresh water station Operating manual en Table of contents Safety instructions... 4 Mode of operation... 5 Hydraulic circuit diagram... 5 Components... 6 Installation...

More information

Heat Link MECHANICAL ROOM IN A BOX. SSP Series. SS Manifold Pump Panel Installation, Operation, and Maintenance Manual. L6SSPxx000x-BMS SSPLR106T

Heat Link MECHANICAL ROOM IN A BOX. SSP Series. SS Manifold Pump Panel Installation, Operation, and Maintenance Manual. L6SSPxx000x-BMS SSPLR106T Heat Link SSP Series SS Manifold Pump Panel Manual NEUTRAL GROUND LIVE CAUTION 115 VOLTS ONLY SSPLR106T GROUND LIVE NEUTRAL CAUTION 115 VOLTS ONLY 120 40 60 60 80 100 C F 200 0 180 20 40 140 160 80 100

More information

hydronics WHAT S WRONG WITH THIS SCHEMATIC?

hydronics WHAT S WRONG WITH THIS SCHEMATIC? BY JOHN SIEGENTHALER WHAT S WRONG WITH THIS SCHEMATIC? In the September/October 2005 issue of HPAC Magazine, methods to draw hydronic piping schematics were discussed. These drawings are an efficient way

More information

We regulate and supply clean energy

We regulate and supply clean energy Bonetti Rubinetterie Valduggia S.r.l. Language English Home The Company News Contacts Download International M2 MIX33 - DN32 We regulate and supply clean energy 2-Way pump unit with 3-way mixing valve

More information

GIACOMINI HEAT INTERFACE UNITS

GIACOMINI HEAT INTERFACE UNITS GIACOMINI HEAT INTERFACE UNITS GENERATION 5 CONTENT 06. FEATURES & BENEFITS 08. TWIN HEAT INTERFACE UNIT 11. SINGLE HEAT INTERFACE UNIT 14. TECHNICAL DATA 17. COMPONENTS 20. ENERG MONITORING 23. DIMENSIONS

More information

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata EKS/HE Refrigerant R410A GWP=2.088 Scroll Compressor Shell & Tube exchanger Axial fan Brazed plate heat exchanger MultiScroll Air-cooled liquid chillers High efficiency Solution B - Base I - Integrata

More information

ProMinent ProMus Hydraulic Diaphragm Metering Pumps

ProMinent ProMus Hydraulic Diaphragm Metering Pumps ProMinent ProMus ProMinent ProMus Description: The ProMus is a motor driven metering pump with a hydraulically actuated diaphragm. The drive case and the hydraulic unit are filled with a liquid that functions

More information

APT and APT14 Automatic Pump Traps. for effective condensate drainage and removal

APT and APT14 Automatic Pump Traps. for effective condensate drainage and removal APT10-4.5 and Automatic Pump Traps for effective condensate drainage and removal 1 An innovative solution for effective heat User benefits Self contained compact unit. Operates with 8 in. installation

More information

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The

More information

FDCL221-Ex Line adapter (Ex)

FDCL221-Ex Line adapter (Ex) FDCL221-Ex Line adapter (Ex) Addressed (FDnet-Ex/C-NET-Ex) For operating FDnet-Ex/C-NET-Ex peripheral devices in potentially explosive areas Sinteso Cerberus PRO Electrical isolation of Ex and non-ex lines

More information

TECHNICAL. Series 18. Pump Packages

TECHNICAL. Series 18. Pump Packages TECHNICAL S Y S T E M S Series 18 Pump Packages Series 18 Pump Packages Standard Features Close-coupled, end-suction, centrifugal pumps Mounted and wired pump starters Hand-Off-Auto switch for each pump

More information

MIX2 - MIX3 MIX2 MIX3 COMPONENTS DESCRIPTION DIMENSIONS

MIX2 - MIX3 MIX2 MIX3 COMPONENTS DESCRIPTION DIMENSIONS TCHNICAL SPCIFICATION DSCRIPTION Thermostatic mixing kit with micrometric valve with thermostatic option, circulation pump (rp Ready 641/2009/C - 622/2012/C), balancing lockshield and couple of manifolds

More information

30% Take lead on your project with an efficient system concept. lower energy.

30% Take lead on your project with an efficient system concept. lower energy. Technical handbook Danfoss EvoFlat systems from A-Z Take lead on your project with an efficient system concept 30% lower energy consumption by individual metering in each apartment www.evoflat.danfoss.com

More information

Sirius FS. Working towards a cleaner future

Sirius FS. Working towards a cleaner future Sirius FS Floor Standing Stainless Steel Condensing Boilers Single Boiler Applications: 50 to 160kW Modular Boiler Applications: up to 640kW Working towards a cleaner future heating specialists 1. Product

More information

CPM, CPMSP Cascade header kits Installation, Commissioning and Maintenance Instructions

CPM, CPMSP Cascade header kits Installation, Commissioning and Maintenance Instructions CPM, CPMSP Cascade header kits Installation, Commissioning and Maintenance Instructions CPM8 CPM77 CPM96 CPM116 CPMSP116 CPM144 CPM17 CPM_ANCIL/CASCADE_V1._December 201 INDEX 1. INTRODUCTION...3 2. MAIN

More information

30% Safe. Take lead on your project with an efficient system concept. Technical handbook Danfoss EvoFlat systems from A-Z. evoflat.danfoss.

30% Safe. Take lead on your project with an efficient system concept. Technical handbook Danfoss EvoFlat systems from A-Z. evoflat.danfoss. MAKING MODERN LIVING POSSIBLE Technical handbook Danfoss EvoFlat systems from A-Z Take lead on your project with an efficient system concept Safe and comfortable EvoFlat systems provide heating and domestic

More information

24/31-28/35-32/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus

24/31-28/35-32/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus 24/31-28/35-32/40 kw Premix System Condensing Combi Gas Boilers Priwa / PriwaPlus 1 Premix System Condensing Combi Gas Boilers 24/31-28/35-32/40 kw Warmhaus wall-hung gas combi boilers Priwa and PriwaPlus,

More information

IDEAL LOGIC HEAT INTERFACE UNITS (HIUs) PRODUCT GUIDE.

IDEAL LOGIC HEAT INTERFACE UNITS (HIUs) PRODUCT GUIDE. IDEAL LOGIC HEAT INTERFACE UNITS (HIUs) RODUCT GUIDE. IDEALCOMMERCIALBOILERS.COM IDEAL COMMERCIAL HEATING SOLUTIONS. Ideal Commercial Boilers is one of the most respected names in the UK commercial and

More information

anti-condensation valve

anti-condensation valve anti-condensation valve Dimensions B C B Function The ltecnic anti-condensation valve connects between a biomass burning boiler and a direct or indirect heating system or domestic hot water system. It

More information

Systems and Tanks. 40 H/V 60 H/V 80 V 115 V 139 V Gallon. Applications Sizing System Design

Systems and Tanks. 40 H/V 60 H/V 80 V 115 V 139 V Gallon. Applications Sizing System Design Systems and Tanks Model size 0 H/V 60 H/V 80 V 5 V 9 V Gallon Applications Sizing System Design Systems In recent years there have been many energy-saving improvements to controls and hydraulics associated

More information

Technical Manual. New Water Cassette. Series BREZZA DOUBLE

Technical Manual. New Water Cassette. Series BREZZA DOUBLE Technical Manual New Water Cassette Series BREZZA DOUBLE AERTESI srl Cassetta BREZZA DOUBLE Tecnical manual AER.MT.I.BREDOPPIA.000.02.15 Pag.2 INDEX 1-INTRODUCTION 4 2- WORKING CONDITION LIMITS..4 3- COANDA

More information

TWO STAGE HEAVY OIL BURNERS

TWO STAGE HEAVY OIL BURNERS TWO STAGE HEAVY OIL BURNERS PRESS N SERIES PRESS 30 N 85/171 342 kw PRESS 45 N 114/205 513 kw PRESS 60 N 171/342 684 kw PRESS 100 N 285/490 1140 kw The PRESS N series of burners covers a firing range from

More information

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES 60 TON AIR-COOLED CHILLER PA-ACCTR-60 Call us today! (800)341-4297 The 60-Ton portable chiller package features a Trane CGAM chiller unit. Trane leads the industry in providing some of the most reliable,

More information

Aquastrom T plus Thermostatic valve with adjustable temperature control range and fixed residual volume flow for circulation pipes

Aquastrom T plus Thermostatic valve with adjustable temperature control range and fixed residual volume flow for circulation pipes Thermostatic valve with adjustable temperature control range Technical information Tender specification: Oventrop thermostatic valve Aquastrom T plus with presetting for circulation pipes. Thermal control

More information

MORE VALUE TO YOUR WELL-BEING

MORE VALUE TO YOUR WELL-BEING Green Comfort, Design and Energy Saving. FCL and FCLI Inverter MORE VALUE TO YOUR ELL-BEING Cassette fan coils Cassette fan coils FCL On-Off / FCLI greater comfort, less consumption The future is Inverter

More information

System Design for efficiency using electronic, intelligent HIU s. Neil Parry CIBSE Accredited Heat Network Consultant

System Design for efficiency using electronic, intelligent HIU s. Neil Parry CIBSE Accredited Heat Network Consultant System Design for efficiency using electronic, intelligent HIU s Neil Parry CIBSE Accredited Heat Network Consultant Family owned Caleffi Four Italian manufacturing sites Total 233,000 square metres Branches

More information

v SELECTION GUIDELINES

v SELECTION GUIDELINES v 2.2-01-2016 SELECTION GUIDELINES 1. SYSTEM PRESENTATION... 3 2. INSTALLATION SIZING... 6 3. SPECIFICATIONS... 11 4. DHW DIAGRAMS... 12 5. HEATING DIAGRAMS... 15 6. COOLING DIAGRAMS... 17 7. PRESSURE

More information

Model: 400E-5M. Bermad Hydraulically Controlled Anti-Columning Deluge Valve, with Easylock Manual Reset. Installation Operation Maintenance

Model: 400E-5M. Bermad Hydraulically Controlled Anti-Columning Deluge Valve, with Easylock Manual Reset. Installation Operation Maintenance Model: 400E-5M Bermad Hydraulically Controlled Anti-Columning Deluge Valve, with Easylock Manual Reset Installation Operation Maintenance Application Engineering Bermad 1. Safety First BERMAD believes

More information

Starting current with soft starter Fuse protection. Heat source connection

Starting current with soft starter Fuse protection. Heat source connection Data sheet SI 17TE Brine-to-water heat pump max. flow temperature: 58 C Casing colour: white Brown-red design screen (RAL 3011) Heat pump for indoor installation with integrated regulation WPM 2007 plus.

More information

Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control.

Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control. Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA 02717 The first totally integrated multiple boiler management control. USING THIS MANUAL USING THIS MANUAL A. INSTALLATION SEQUENCE Follow

More information

Flow Reversal in Primary/Secondary Systems by John Siegenthaler, P.E. April 17, 2007

Flow Reversal in Primary/Secondary Systems by John Siegenthaler, P.E. April 17, 2007 Flow Reversal in Primary/Secondary Systems by John Siegenthaler, P.E. April 17, 2007 When flow reversal occurs, the heat transfer from the secondary circuit is mostly unaffected, as are the other secondary

More information

Ve r s a - Hyd ro. 96% Efficient. The cost effec t i ve. ersa-hydro

Ve r s a - Hyd ro. 96% Efficient. The cost effec t i ve. ersa-hydro ersa-hydro Versa- Hydro 96% Efficient The cost effec t i ve Ve r s a - Hyd ro combines space heating, domestic hot water, and total system control into one compact, high efficiency mod-con unit. I n n

More information

DIRTCAL - DIRTMAG dirt separator

DIRTCAL - DIRTMAG dirt separator 864.07 www.caleffi.com DIRTCAL - DIRTMAG dirt separator Copyright 206 Caleffi 5462-546 -5465-5465M - NA5465 - NA5465M Series Installation, commissioning and servicing instructions Function In heating and

More information

ACCREDITED. Product range Code A2L Modulating temperature regulating unit for heating and cooling, with ALPHA2 L pump.

ACCREDITED. Product range Code A2L Modulating temperature regulating unit for heating and cooling, with ALPHA2 L pump. Modulating temperature regulating unit for heating and cooling 7 series ACCREDITED ISO FM ا ٠١١٥٢/١٥ replaces /7 GB Function The temperature regulating unit is made to be used in radiant panel systems

More information

GHP AWO 38 Technical overview

GHP AWO 38 Technical overview Gas absorption heat pump 9 Technical overview single unit G&' &(')*ption heat pump components. 1 7 2 8 9 3 4 10 8 5 6 1 +),-.&/012 &0* ')-*34 5&1 2 G414*&/)* 3 G&' (-*ner 4 6)1,41'4* 5 6)7(-'/0)1 38&7(4*

More information

RK 50. High Efficiency Condensing Wall Hung Boiler Heating Only. Suitable for Cascade Systems SEDBUK BAND A CE 0694 TA01E011.A0405 TA05E011.

RK 50. High Efficiency Condensing Wall Hung Boiler Heating Only. Suitable for Cascade Systems SEDBUK BAND A CE 0694 TA01E011.A0405 TA05E011. High Efficiency Condensing Wall Hung Boiler Heating Only RK 50 Suitable for Cascade Systems SEDBUK BAND A CE 069 CE 069 RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY RADIANT BRUCIATORI S.p.A. Montelabbate

More information

HyBo - Hydraulic Interface Unit AMBIENT HEATING AND DOMESTIC HOT WATER PRODUCTION FOR CENTRAL HEATING SYSTEM UNIT CODE EHIU1

HyBo - Hydraulic Interface Unit AMBIENT HEATING AND DOMESTIC HOT WATER PRODUCTION FOR CENTRAL HEATING SYSTEM UNIT CODE EHIU1 HyBo - Hydraulic Interface Unit AMBIENT HEATING AND DOMESTIC HOT WATER PRODUCTION FOR CENTRAL HEATING SYSTEM UNIT CODE EHIU1 INSTALLATION, COMMISSIONING AND OPERATING INSTRUCTIONS Contents Unit as delivered

More information

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45 Plug & Heat heat pump Quick and easy to install For new homes or boiler backup operation 50 HFC R410A CERTIFIED BY CERTITA Heating capacity: 5.5 to 22 kw option CERTIFIED BY CERTITA 30/35-40/45 USE The

More information

Installation and Commissioning Instructions

Installation and Commissioning Instructions Installation and Commissioning Instructions FMU Floor Mixing Unit with Lowara Ecocirc Class A Pump Pre-assembled TM Thermostatic Mixing Control Group and manifold with either lockshields or flowmeters,

More information

VST Series. INAIL approved and calibrated safety valves. Technical Data Sheet. WattsIndustries.com

VST Series. INAIL approved and calibrated safety valves. Technical Data Sheet. WattsIndustries.com VST Series INAIL approved and calibrated safety valves Technical Data Sheet WattsIndustries.com Description VST Series INAIL approved and calibrated safety valves automatically discharge enough liquid

More information

ThermoDual Domestic hot water charging system

ThermoDual Domestic hot water charging system ThermoDual Domestic hot water charging system Description/Application ThermoDual is the compact and effective domestic hot water (DHW) charging system. Due to the consistent use of carefully selected components

More information

24/31-28/35-33/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus.

24/31-28/35-33/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus. combi boilers panel radiators 24/31-28/35-33/40 kw Premix System Condensing Combi Gas Boilers Priwa / PriwaPlus www.warmhaus.com 1 Premix System Condensing Combi Gas Boilers 24/31-28/35-33/40 kw Warmhaus

More information

1 VICTRIX ZEUS Superior kw I features

1 VICTRIX ZEUS Superior kw I features Wall-hung condensing VICTRIX ZEUS Superior kw I is the new range of wall-hung condensing boilers with 54 litre stainless steel storage tank available in two versions with nominal heat output of 26 kw and

More information

Morco Products Ltd. Winterisation of Holiday Homes. General

Morco Products Ltd. Winterisation of Holiday Homes. General Morco House Riverview Road Beverley HU17 0LD Morco Products Ltd Tel: 01482 325456 Fax: 01482 212869 Email sales@morcoproducts.co.uk Web www.morcoproducts.co.uk Winterisation of Holiday Homes General Fresh

More information