DCH Commercial. 6 Ton Packaged Heat Pumps Up to 15.5 IEER 8.0 HSPF. Cooling Capacity: Up to 71,000 BTU/h Heating Capacity: Up to 70,000 BTU/h

Size: px
Start display at page:

Download "DCH Commercial. 6 Ton Packaged Heat Pumps Up to 15.5 IEER 8.0 HSPF. Cooling Capacity: Up to 71,000 BTU/h Heating Capacity: Up to 70,000 BTU/h"

Transcription

1 DCH Commercial 6 Ton Packaged Heat Pumps Up to 15.5 IEER 8.0 HSPF Cooling Capacity: Up to 71,000 BTU/h Heating Capacity: Up to 70,000 BTU/h Contents Nomenclature... 2 Product Specifications... 4 Expanded Cooling Data... 5 Airflow Data... 7 Expanded Heating Data... 8 Crankcase Heater... 9 Electrical Data / Heat Kit Data Dimensions Wiring Diagrams for Models with DDC Controls Accessories Standard Features High-efficiency scroll compressor Copper tube / aluminum fin coils High- and low-pressure switches Refrigerant accumulator Contactor with lugs High-capacity, steel-cased filter drier Heater kits with single-point entry 24-volt terminal strip Convertible airflow orientation Easy to service Built-in filter rack with standard 2" filters Bottom utility entry AHRI Certified; ETL Listed 6-ton with two-speed blower motor and twostage compressor meet the performance specified as of 1/1/2016 in Table of ASHRAE STANDA Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan * Complete warranty details available from your local distributor or manufacturer s representative or at SS-DCH6 1/18 Supersedes 12/17

2 Nomenclature D C H V * * * A * 1 2 4,5,6 7,8, Revision Levels Major & Minor Brand Factory-Installed Options D Daikin X No Options A Non-powered convenience outlet Configuration B Powered convenience outlet C Standard Efficiency (6-25 Tons) C Low-ambient kit S Standard Efficiency ( - 5 Tons) D Return air smoke detector T High Efficiency ( - 5 Tons) E Supply air smoke detector F Non-powered convenience outlet; Application Low-ambient kit C Cooling 1 G Non-powered convenience outlet; G Gas Heat Return air smoke detector H Heat Pump 1 H Non-powered convenience outlet; Supply air smoke detector Nominal Cooling Capacity J Non-powered convenience outlet; 06 Tons 102 8½ Tons Tons Return & Supply air smoke detectors Tons Tons K Non-powered convenience outlet; Tons ½ tons Low-ambient kit; Supply air smoke detector Tons Tons L Non-powered convenience outlet; 090 7½ Tons Tons Low-ambient kit Return & Supply air smoke detectors Nominal Heating Capacity M Powered convenience outlet; Gas/Electric A/C H/P Factory-Installed Electric Heat Low-ambient kit ,000 BTU/h XXX No Heat N Powered convenience outlet; ,000 BTU/h kw 00 0 kw Return air smoke detector ,000 BTU/h kw 01 0 kw O Powered convenience outlet; ,000 BTU/h kw kw Return & Supply air smoke detectors ,000 BTU/h kw kw P Powered convenience outlet; 50 50,000 BTU/h kw kw Supply air smoke detector ,000 BTU/h kw Q Powered convenience outlet; Low-ambient See product specifications for heat size(s) available for each capacity. kit; Return air smoke detector R Powered convenience outlet; Low-ambient Voltage kit; Supply air smoke detector /1/60 (DS* & DT* -5 Tons models only) 4 460//60 T Powered convenience outlet; Low-ambient // //60 kit; Return & Supply air smoke detectors U Non-powered convenience outlet; Supply Fan/Drive Type/Motor Low-ambient kit; Return air smoke detector B Belt Drive (-5 Tons single speed models only) V Two-Speed Belt Drive V Low-ambient kit; Return air smoke detector D Direct Drive (-5 Tons single speed models only) (6-25 Tons only) W Low-ambient kit; Supply air smoke detector H High Static (-5 Tons single-speed Belt W High Static (6-25 Tons Y Low-ambient kit; Return & Supply Drive models only) two-speed Belt Drive air smoke detectors models only) Z Return & Supply air smoke detectors Factory-Installed Options A Ultra Low-Leak Downflow Economizer R Ultra Low-Leak Downflow Economizer; B DDC-BACnet protocol DDC-BACnet protocol; F Ultra Low-Leak Downflow Economizer; Disconnect Switch (non-fused) Factory-Installed Options DDC-BACnet protocol V Low-Leak Downflow Economizer X Standard Aluminized Heat Exchanger H Disconnect Switch (non-fused) W Low-Leak Downflow Economizer S Stainless-Steel Heat Exchanger J Ultra Low-Leak Downflow Economizer; Disconnect Switch (non-fused) D Hinged Panels Disconnect Switch (non-fused) X No Options K Stainless-Steel Heat Exchanger; M Disconnect Switch (non-fused); DDC-BACnet protocol Hinged Panels B Phase Monitor Note: Not all options available for all products. J Stainless Steel Heat Exchanger; Phase Monitor 1 X= No Options in character 1th M Hinged Panel; Phase Monitor L Stainless-Steel Heat Exchanger; Hinged Panels; Phase Monitor 2 SS-DCH6

3 Nomenclature Factory-Installed Options Stainless-Steel Heat Exchanger (Gas only units): A tubular heat exchanger made of 409-type stainless steel is installed in the unit. Low-Ambient Kit: Allows for cooling operation at lower outdoor temperatures. On the - to 6-ton units, cooling operation is extended from 60 F ambient temperature to 5 F outside air temperature. On 7½ -20 ton units, cooling operation is extended from 5 F ambient temperature to 0 F outside air temperature. For 25 ton units, cooling operation is extended from 24 F ambient temperature to 0 F outside air temperature. Economizers (Downflow): Based on air conditions, can provide outside air to cool the space. Electric Heat Kits (A/C and Heat Pump units only): Available in all voltage options. Non-powered Convenience Outlet: A 120V, 15A, GFCI outlet makes it easier for technicians to service the unit once an electrician runs power to the outlet. Powered Convenience Outlet: A 120V, 15A, GFCI outlet powered with a transformer built into the unit. When a factory-installed powered convenience outlet is installed in the equipment, the unit MCA (Min. Circuit Ampacity) will increase by 7.2A/6.5A for 208/20V units, increase by.a for 460V units, and by 2.6A for 575V units. The MOP (Max. Overcurrent Protection) device must be sized accordingly. Disconnect Switch (non-fused; -phase units only): A disconnect switch is installed in the unit and factory wiring will be complete from the switch to the unit. Please note that for air conditioning and heat pump models, the appropriate electric heat kit must be ordered to be factory-installed along with the disconnect switch (non-fused) when it is ordered. Please note that for models with a powered convenience outlet option and a disconnect switch (non-fused) option, the power to the powered convenience outlet will be shut off when the disconnect switch (non-fused) is in the off position. Return Air and/or Supply Air Smoke Detectors: Return air and/or supply air smoke detectors are installed in the unit. Hinged Access Panels: Allows access to unit s major components. Combined with latches for easy access to control box, compressor, filters and blower motor. Available on all units. Two-speed indoor fan blower models are standard on 6, 7½, 8½, 10, 12½, 15, 20 & 25 ton units. Section b of ASHRAE Standard and Section a of ASHRAE Standard require a minimum of two fan speeds. Section 140.4(m)1 of California Energy Commission Title contains a similar provision. When the units with the two-speed indoor fan blowers operate on a call for the first stage of cooling, the fan operates at low speed, which is 66% of full speed. When the units operate on a call for the second stage of cooling, the fan operates at full speed. In heating operation, the fan operates at full speed. During ventilation operation, the fan operates at low speed. Phase Monitor: Phase monitor ( phase only), available for - 25 ton DS, DC and DT series models. Phase monitor shall provide protection for motors and compressors against problems caused by phase loss, phase reversal and phase unbalance. Phase monitor is equipped with an LED that provides an ON or FAULT indicator. DDC Controller: DDC communicating controller, available for - 25 ton DS, DC and DT series models with on-board BACnet communication interface. High static blower assembly, factory-installed. SS-DCH6

4 Product Specifications 6 Tons DCH072 ***V***A* DCH072 ***4V***A* DCH072 ***7V***A* Cooling Capacity Total BTU/h 69,000 69,000 69,000 Sensible BTU/h 50,000 50,000 50,000 EER / IEER 11.2/ / /15.0 Decibels AHRI Number Heating Capacity BTU/h (47 F) 69,000 69,000 69,000 COP (47 F) BTU/h (17 F) 8,000 8,000 8,000 COP (17 F) Evaporator Motor / Coil Motor Type 2-speed Belt Drive 2-speed Belt Drive 2-speed Belt Drive # of Wheels (D x W) 1 (11" x 10") 1 (11" x 10") 1 (11" x 10") Indoor Nominal CFM 2,50 2,50 2,50 Motor Speed Tap (Cooling) Indoor Motor FLA (Cooling) Horsepower - RPM 2.0-1, , ,725 Piston Size (Cooling) TXV TXV TXV Filter Size (Qty) (4) 16" x 20" x 2" (4) 16" x 20" x 2" (4) 16" x 20" x 2" Drain Size (NPT) ¾" ¾" ¾" R-410A Refrigerant Charge (oz.) Evaporator Coil Face Area (ft²) Rows Deep/ Fins per Inch 4/16 4/16 4/16 Motor Sheave VL44 X 7/8 VL44 x 7/8 VL44 x 7/8 Blower Sheave / Belt AK59x1 / AX5 AK59x1 / AX5 AK59x1 / AX5 Condenser Fan / Coil Quantity of Condenser Fan Motors Horsepower - RPM ⅓ - 1,075 ⅓ - 1,075 ⅓ - 1,075 Fan Diameter/ # Fan Blades 22/ 4 22/ 4 22/ 4 Outdoor Nominal CFM 4,00 4,00 4,00 Face Area (ft²) Rows Deep/ Fins per Inch 2/ 20 2/ 20 2/ 20 Piston Size (Heating) Compressor Quantity / Stage 1 /Two 1 /Two 1 /Two Type Scroll Scroll Scroll Compressor RLA / LRA 17.6/16 8.5/ /55. Electrical Data Voltage/ Phase/ Frequency 208/ Outdoor Fan FLA Total Unit Amps Min. Circuit Ampacity¹ 0 / Max. Overcurrent Protection (amps)² 45 / Entrance Power Supply 1.125" 1.125" 1.125" Entrance Control Voltage ½" ½" ½" Operating Weight (lbs) Ship Weight (lbs) ¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. ² May use fuses or HACR-type circuit breakers of the same size as noted. Notes Always check the S&R plate for electrical data on the unit being installed. When a factory-installed powered convenience outlet is installed in the equipment, the unit MCA (Min. Circuit Ampacity) will increase by 7.2A/6.5A for 208/20V units, increase by.a for 460V units, and by 2.6A for 575V units. The MOP (Max. Overcurrent Protection) device must be sized accordingly. 4 SS-DCH6

5 Expanded Cooling Data 6 Tons (2 Speed) Outdoor Ambient Temperature Entering Indoor Wet Bulb Temperature IDB Airflow MBh S/T Delta T KW HI PR LO PR MBh S/T Delta T KW HI PR LO PR MBh S/T Delta T KW HI PR LO PR MBh S/T Delta T KW HI PR LO PR MBh S/T Delta T KW HI PR LO PR MBh S/T Delta T KW HI PR LO PR IDB = Entering Indoor Dry Bulb Temperature Shaded area reflects AA (TVA) conditions kw = Total system power High & low pressures are measured at the liquid & suction service ports. Amps: Unit amps (comp.+ evaporator + condenser fan motors) SS-DCH6 5

6 Expanded Cooling Data 6 Tons (2 Speed) (cont.) Outdoor Ambient Temperature Entering Indoor Wet Bulb Temperature IDB Airflow MBh S/T Delta T KW HI PR LO PR MBh S/T Delta T KW HI PR LO PR MBh S/T Delta T KW HI PR LO PR MBh S/T Delta T KW HI PR LO PR MBh S/T Delta T KW HI PR LO PR MBh S/T Delta T KW HI PR LO PR IDB = Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions kw = Total system power High & low pressures are measured at the liquid & suction service ports. Amps: Unit amps (comp.+ evaporator + condenser fan motors) 6 SS-DCH6

7 Airflow Data 6 Tons ESP ("W.C.) DCH072 Two-Speed Standard Belt Drive At High Speed - Horizontal 0 Turns 1 Turn 2 Turns Turns 4 Turns 5 Turns CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP ESP ("W.C.) DCH072 Two-Speed Standard Belt Drive At High Speed - Down Shot 0 Turns 1 Turn 2 Turns Turns 4 Turns 5 Turns CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP ESP ("W.C.) DCH072 High Static Belt Drive at High Speed Horizontal 0 Turns 1 Turn 2 Turns Turns 4 Turns 5 Turns CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP ESP ("W.C.) DCH072 High Static Belt Drive at High Speed Down Shot 0 Turns 1 Turn 2 Turns Turns 4 Turns 5 Turns CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP Note: Tables represent dry coil without filter; to compensate for filter, add 0.08" to measured E.S.P. Air Flow Pressure Drop of Down Flow Economizer Airflow Pressure Drop of Downflow Economizer for to 6 Ton Rofftop Units (100% Return Air) SCF, in WG SS-DCH6 7

8 Expanded Heating Data DCH072****V***A* Outdoor Ambient Temperature MBh T/R KW COP EER HI PR LO PR Above information is for 2150 CFM & 70º indoor dry bulb; instantaneous capacity listed. High pressure measured at liquid line access fitting. Low pressure measured at compressor suction access fitting. kw = Total system power Amps: Unit Amps (comp+evap motor+condenser fan motor) 8 SS-DCH6

9 Crankcase Heater, High Efficiency MERV 1 Air Filter Option High Efficiency MERV 1 Air Filter Option 0.50 Flanders Pre Pleat M1 Air Velocity vs Resistance (Test Size: 24" x 24" x 2" High Capacity) " Deep Resistance (in. w.g.) Air Velocity (FPM) Tonnage: Filter Nominal Size: Part Number: Order QTY: 6 16 x 20 x L Crankcase Heater Selection Table Compressor Voltage Crankcase ZP/ZPS Compressor Diameter 20V 460V 575V Heater Watts " 016R00002S 016R0001S 016R0002S /7." 010L00017S 010L00018S 010L00019S L00020S 010L00021S 010L00022S 90 DC*,DT* & DS* Tonnage Compressor Voltage 20V 460V 575V Crankcase Heater Watts 6 Ton 010L00017S 010L00018S 010L00019S 70 *Includes C,G&H models. SS-DCH6 9

10 Electrical Data Model Number Electrical Rating Compressor Circuit 1 Compressor Circuit 2 Outdoor Fan Motor Indoor Fan Motor Optional Electric Heat Optional Powered Unit Power Supply Convienience Outlet RLA LRA RLA LRA QTY HP FLA Type HP FLA Model KW* FLA FLA MCA MOP / / 45 EHK / / / / 70 EHK / / / / 80 DCH072XXXW 208/ EHK / / / / 90 2-speed EHK / / / / 110 High Static / / / 50 Belt Drive EHK / / / / / 70 EHK / / / / / 90 EHK / / / / / / / / / / 125 DCH072XXXV 208/ speed Belt Drive DCH072XXX4W DCH072XXX4V DCH072XXX7W D072XXX7V speed High Static Belt Drive 2-speed Belt Drive 2-speed High Static Belt Drive 2-speed Belt Drive) * Elecric Heater kw rating: Rated at 240v for v units; 480v for 460v units / / 45 EHK / / / / 70 EHK / / / / 80 EHK / / / / 90 EHK / / / / / / / 50 EHK / / / / / 70 EHK / / / / / 90 EHK / / / / / 100 EHK / / / / / EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK EHK SS-DCH6

11 Heat Kit Electrical Data 6 Tons Model and Heat Kit Usage DCH072***V*** EHK-10 EHK-15 EHK-20 EHK-25 Model and Heat Kit Usage DCH072***4V*** EHK4-10 EHK4-15 EHK4-20 EHK4-25 Recommended Airflow Range 2,100-2,700 CFM 2,100-2,700 CFM 2,100-2,700 CFM 2,100-2,700 CFM Recommended Airflow Range 2,100-2,700 CFM 2,100-2,700 CFM 2,100-2,700 CFM 2,100-2,700 CFM kw Correction Factors kw Correction Factor for 1- & -Phase Units Supply Voltage Correction Factor For other voltage use votlage 2 / kw Correction Factor for 480V Units Actual Voltage Correction Factor For other voltage use voltage² / 480² kw Correction Factor for 575V Units Supply Voltage Correction Factor For other voltage use voltage² / 575² Multiply rated kw by correction factor to get actual kw Model and Heat Kit Usage DCH072***7V*** EHK7-10 EHK7-15 EHK7-20 EHK7-25 Recommended Airflow Range 2,100-2,700 CFM 2,100-2,700 CFM 2,100-2,700 CFM 2,100-2,700 CFM Note: All heaters have single-point entry kit SS-DCH6 11

12 Dimensions TOP VIEW FLUE/VENT OUTLET COMBUSTION AIR INLET (GAS UNITS) GAS LINE ENTRANCE FRONT VIEW ALL DIMENSIONS GIVEN ARE IN INCHES ALL DIMENSIONS AND SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE SUPPLY AIR DUCT DCH072*** 6 TON COMMERCIAL CONDENSATE DRAIN OUTLET LIFTING SHACKLE HOLES BOTH SIDES AND ENDS FK HOLES BOTH SIDES AND BOTH ENDS RIGHT END VIEW RETURN AIR DUCT 12 SS-DCH6

13 Dimensions (cont.) CONDENSATE DRAIN BOTTOM EXIT SUPPLY AIR DUCT RETURN AIR DUCT CONDENSATE DRAIN BOTTOM EXIT BASE PAN VIEW (VIEWED FROM TOP) LINE WIRE ENTRANCE TSTAT WIRE ENTRANCE LEFT END VIEW AIR DUCT PAN VIEW FROM TOP) SS-DCH6 1

14 Unit Clearances Maintain an adequate clearance around the unit for safety, service, maintenance, and proper unit operation. Leave a clearance of 48" on all sides of the unit for possible compressor removal or service access, and to ensure proper ventilation and condenser airflow. Do not install the unit beneath any obstruction. Install the unit away from all building exhausts to inhibit ingestion of exhaust air into the unit s fresh-air intake. 48" 48" 48" 48" Electrical Entrance Locations High-Voltage Entrance (Remove Plug) 12⅜ ½ Dia. 0¼ Power Thru the Curb Low-Voltage Entrance 47½ 7½ Corner & Center-of-Gravity Locations Unit Weights 6-Ton Weights 0 Condenser Coil Return Evaporator Coil Corner Weight (A) 145 Corner Weight (B) 205 Corner Weight (C) 125 Corner Weight (D) 175 Supply Unit Shipping Weight 675 Unit Operating Weight 650 Compressor Note: Weights are calculated without accessories installed SS-DCH6

15 Roof Curb Installation Rigging Provisions for forks have been included in the unit base frame. No other fork locations are approved. Unit must be lifted by the four lifting holes located at the base frame corners. Lifting cables should be attached to the unit with shackles. The distance between the crane hook and the top of the unit must not be less than 60. Two spreader bars must span over the unit to prevent damage to the cabinet by the lift cables. Spreader bars must be of sufficient length so that cables do not come in contact with the unit during transport. Remove wood struts mounted beneath unit base frame before setting unit on roof curb. These struts are intended to protect unit base frame from fork lift damage. To remove the struts, extract the sheet metal retainers and pull the struts through the base of the unit. Refer to rigging label on the unit. Important: If using bottom discharge with roof curb, duct-work should be attached to the curb prior to installing the unit. Duct-work dimensions are shown in Roof Curb Installation Instructions Manual. Refer to the Roof Curb Installation Instructions for proper curb installation. Curbing must be installed in compliance with the National Roofing Contractors Association Manual. Lower unit carefully onto roof mounting curb. While rigging the unit, the center of gravity will cause the condenser end to be lower than the supply air end. Bring condenser end of unit into alignment with the curb. With condenser end of the unit resting on curb member and using curb as a fulcrum, lower opposite end of the unit until entire unit is seated on the curb. When a rectangular cantilever curb is used, take care to center the unit. Check for proper alignment and orientation of supply and return openings with duct. To assist in determining rigging requirements, unit weights are shown below. Curb installations must comply with local codes and should follow the established guidelines of the National Roofing Contractors Association. Proper unit installation requires that the roof curb be firmly and permanently attached to the roof structure. Check for adequate fastening method prior to setting the unit on the curb. Full perimeter roof curbs are available from the factory and are shipped unassembled. The installing contractor is responsible for field assembly, squaring, leveling, and mounting on the roof structure. All required hardware necessary for the assembly of the sheet metal curb is included in the curb accessory package. Determine sufficient structural support before locating and mounting the curb and package unit. Duct-work must be constructed using industry guidelines. The duct-work must be placed into the roof curb before mounting the package unit. Our full perimeter curbs include duct connection frames to be assembled with the curb. Cantilevered-type curbs are not available from the factory. Contractor furnishes curb insulation, cant strips, flashing, and general roofing material. Support curbs on parallel sides with roof members. To prevent damage to the unit, the roof members cannot penetrate supply and return duct openings. Note: The unit and curb accessories are designed to allow vertical duct installation before unit placement. Duct installation after unit placement is not recommended. See the manual shipped with the roof curb for assembly and installation instructions. -D View Top View Insulated Panels TYP O.D ¾ 40¼ S/A x 20 Supply Opening 1⅝ x 14 Return Opening 1 5 /6 ¾ 14 1⅜ O R/A I.D I.D. O.D. SS-DCH6 15

16 CONTROLS DIAAM DCH072 2 SPEED EM 2 STAGE COMP Wiring Diagram Control Diagram DCH072XXX*V - 2 Speed (All Voltages) FIELD CONTROL WIRING CLASS CLASS 2 FIELD CONTROL WIRING G W1 W2 Y1 Y2 O TB1 TB TB1 S1 S2 R C TR1 SUPPLY (LINE) VOLTAGE TB GY GY DR GY GY SSHR GY EBTDR R XFMR-R G XFMR-C GY GY NO COM NC SPEED-UP 6 GY HPS /PK /PK LPS /PK /PK DFT 24 VAC GY DC GY Y CNT W R O GY R-PS1 O-RV PS2 C-RV R-DFT C DFT DF1 DF2 RVC CMR GY BC1 GY 1 BC2 PLF CHS CS CHR 7 ECON PLF ECON SHRT PLM G ECON PLM OPTIONAL ECONOMIZER 2 1 PK MAT 1 2 AUX2-I PK MAT 2 O OAT 4 E- OAT EXH1 S-BUS S-BUS 6 2 AUX1-O 1 Y2-I IAQ Y2-O IAQ COM Y1-I IAQ 24V 4 4 Y1-O ACT COM 5 1 C ACT 24V 6 2 R MAS -t ENTH ECON ACT 4 S-BUS S-BUS 2 24V-COM 1 24V-PWR PK OPTIONAL SMOKE DETECT V AC/DC 9 10 AUX A AUX B SENS 1 SENS 2 PK Y Y R B Y Y R B Y Y R B Y Y R B 5 SEN1 SEN2 1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE OF INSULATION AS IGINAL (USE COPPER CONDUCTS ONLY). 2 IF OPTIONAL ECONOMIZER IS INSTALLED, REMOVE ECON SHRT PLM AND CONNECT ECON PLM TO ECON PLF. TB LOW VOLTAGE TERMINAL OCK. 4 TERMINALS F (+)24VAC-PWR (, WIRE),AND 6 TERMINALS F (-) 24VAC-COM ( WIRE). 4 CONNECTIONS SHOWN ARE F 1-STAGE HEAT OPERATION. EN 2-STAGE OPERATION IS REQIRED REMOVE JUMPER WIRE CONNECTING W2 TO W1 ON TB1. 5 IF OPTIONAL SMOKE DETECT(S) ARE INSTALLED, REMOVE JUMPER WIRE CONNECTING S1 TO S2 ON TB1. WIRE CONNECTIONS FROM AESSY KIT: CONNECT WIRE TO TB1-S1. CONNECT WIRE TO TB1-S2. CONNECT TO TB,(24 COM). 6 EBTDR: FAN ENERGIZED 7 SEC AFTER 24V APPLIED TO "G". FAN DE-ENERGIZED 65 SEC AFTER 24V REMOVED FROM "G". IF SPEED-UP TERMINAL IS SHTED TO OUND ALL DELAYS ARE REDUCED TO ~5 SEC. 7 CMR, CHR AND ALL ASSOCIATED WIRING IS ONLY PRESENT ON (460/575)V MODELS. F 20V MODELS SEE POWER DIAAM F CM AND H WIRING. 8 PLF1 CONNECT F OPTIONAL ELECTRIC HEAT. SEE ELECTRIC HEAT SCHEMATIC F WIRING CONNECTIONS. 0140L04967-A Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. Warning High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death SS-DCH6

17 Wiring Diagram Power Diagram DCH072-2 Speed (20V) LINE VOLTAGE L1 L2 L CHS H POWER DIAAM DCH072*** 2 SPEED EM 2 STAGE COMP FACTY WIRING HIGH VOLTAGE OPTIONAL HIGH VOLTAGE LOW VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE BC H CHS CM COMP CS DC DFT COMPONENT LEGEND OWER CONTACT OWER RELAY COMPRESS CONTACT CRANKCASE HEATER CRANKCASE HEATER SWITCH CONDENSER MOT COMPRESS COMPRESS 2ND STAGE SOLENOID DEFROST CONTROL DEFROST THERMOSTAT SWITCH DC DF1 DF2 L1 T1 L2 T2 L T FC T1 T2 T COMP CM WIRE CODE ACK UE OWN EEN GY AY ANGE PK PINK RPLE RED ITE YELLOW /PK UE/ PINK STRIPE /PK YELLOW/ PINK STRIPE DR DEFROST ISOLATION RELAY EBTDR EVAPAT OWER TIME DELAY RELAY ECON ECONOMIZER EM EVAPAT MOT FC FAN CAPACIT EQUPIMENT OUND HPS HIGH PRESSURE SWITCH LPS LOW PRESSURE SWITCH PLF PLUG / CONNECT, FEMALE PLM PLUG / CONNECT, MALE RVC REVERSING VALVE COIL SSHR 2ND STAGE HEAT RELAY TB1 TERMINAL OCK 1, LOW VOLTAGE TB TERMINAL OCK, LOW VOLTAGE TR1 TRANSFMER 1, CONTROLS (LINE VOLTAGE / 24VAC) THERMOSTAT CONNECTIONS BC1 L1 T1 (12) THERMOSTAT IN / OUT 24VAC-PWR (INT) TB1 CONNECTION R L2 T2 L T BC2 L1 T1 L2 T2 (11) (1) EM 6 24VAC - COM (INT) FAN CALL (OUTT) 1ST STAGE HEAT CALL (OUTT) 2ND STAGE HEAT CALL (OUTT) 1ST STAGE COOL CALL (OUTT) 2ND STAGE COOL CALL (OUTT) C G W1 W2 Y1 Y2 GY GY L T 4 24V CNTL VOLTAGE TR1 2, LINE VOLTAGE NOTES: 1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE OF INSULATION AS IGINAL (USE COPPER CONDUCTS ONLY). UNIT TERMINALS ARE NOT DESIGNED F OTHER CONDUCTS THE USE OF OTHER TYPE CONDUCTS MAY CAUSE DAMAGE TO THE UNIT 2 THE CONTROL TRANSFMER HAS MULTIPLE HIGH VOLTAGE TAPS. ENSURE WIRE CONNECTIONS ARE CRECT F UNIT SUPPLY VOLTAGE RATING 208/20V SUPPLY POWER UNITS ARE FACTY CONNECTED TO THE CONTROL TRANSFMER 240V TAP. MOVE WIRE CONNECTION FROM 240V TAP TO 208V TAP EN 208V POWER SUPPLY IS USED. 4 SEE CONTROL DIAAM F CONTROL TRANSFMER LOW VOLTAGE CONNECTIONS 5. SEE AESSY KIT LITERATURE F OPTIONAL CONVENIENCE OUTLET WIRING DIAAM. 6 2 SPEED EVAPAT MOT: ACK LEADS F HIGH SPEED OPERATION, AND ITE / UE / ANGE LEADS F LOW SPEED OPERATION. 0140L0549-A Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. Warning High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. SS-DCH6 17

18 Wiring Diagram Power Diagram DCH072-2 Speed (460/575) LINE VOLTAGE L1 L2 L CHR 1 H POWER DIAAM DCH072***(4/7) 2 SPEED EM 2 STAGE COMP FACTY WIRING HIGH VOLTAGE OPTIONAL HIGH VOLTAGE LOW VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE BC H CHR CHS CM CMR COMPONENT LEGEND OWER CONTACT OWER RELAY COMPRESS CONTACT CRANKCASE HEATER CRANKCASE HEATER RELAY CRANKCASE HEATER SWITCH CONDENSER MOT CONDENSER MOT RELAY COMP CS COMPRESS COMPRESS 2ND STAGE SOLENOID DC DEFROST CONTROL L1 L2 L 1 CMR T1 T2 T FC T1 T2 T COMP CM WIRE CODE ACK UE OWN EEN GY AY ANGE PK PINK RPLE RED ITE YELLOW /PK UE/ PINK STRIPE /PK YELLOW/ PINK STRIPE DFT DEFROST THERMOSTAT SWITCH DR DEFROST ISOLATION RELAY EBTDR EVAPAT OWER TIME DELAY RELAY ECON ECONOMIZER EM EVAPAT MOT FC FAN CAPACIT EQUPIMENT OUND HPS HIGH PRESSURE SWITCH LPS LOW PRESSURE SWITCH PLF PLUG / CONNECT, FEMALE PLM PLUG / CONNECT, MALE RVC REVERSING VALVE COIL SSHR 2ND STAGE HEAT RELAY TB1 TERMINAL OCK 1, LOW VOLTAGE TB TERMINAL OCK, LOW VOLTAGE TR1 TRANSFMER 1, CONTROLS (LINE VOLTAGE / 24VAC) BC1 L1 T1 (12) THERMOSTAT CONNECTIONS THERMOSTAT TB1 IN / OUT CONNECTION L2 T2 L T BC2 L1 T1 L2 T2 (11) (1) EM 6 24VAC-PWR (INT) 24VAC - COM (INT) FAN CALL (OUTT) 1ST STAGE HEAT CALL (OUTT) 2ND STAGE HEAT CALL (OUTT) 1ST STAGE COOL CALL (OUTT) R C G W1 W2 Y1 L T GY GY 2ND STAGE COOL CALL (OUTT) Y2 4 24V CNTL VOLTAGE TR1 2, LINE VOLTAGE NOTES: 1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE OF INSULATION AS IGINAL (USE COPPER CONDUCTS ONLY). UNIT TERMINALS ARE NOT DESIGNED F OTHER CONDUCTS THE USE OF OTHER TYPE CONDUCTS MAY CAUSE DAMAGE TO THE UNIT 2 THE CONTROL TRANSFMER HAS MULTIPLE HIGH VOLTAGE TAPS. ENSURE WIRE CONNECTIONS ARE CRECT F UNIT SUPPLY VOLTAGE RATING 208/20V SUPPLY POWER UNITS ARE FACTY CONNECTED TO THE CONTROL TRANSFMER 240V TAP. MOVE WIRE CONNECTION FROM 240V TAP TO 208V TAP EN 208V POWER SUPPLY IS USED. 4 SEE CONTROL DIAAM F CONTROL TRANSFMER LOW VOLTAGE CONNECTIONS 5. SEE AESSY KIT LITERATURE F OPTIONAL CONVENIENCE OUTLET WIRING DIAAM. 6 2 SPEED EVAPAT MOT: ACK LEADS F HIGH SPEED OPERATION, AND ITE / UE / ANGE LEADS F LOW SPEED OPERATION. 0140L05440-A Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. Warning High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death SS-DCH6

19 WIRING DIAAMS F MODELS WITH DDC CONTROLS For complete information and installation instructions for models with DDC controls, see manual DK-DDC-TGD-XXX SS-DCH6 19

20 Wiring Diagram with DDC DDC - DCH072***(208-20//60)V*** BI1 BI2 /PK BI RSS BI4 LDS CFS BI5 BI6 BI7 BI8 DFT Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. POWER SUPPLY //60 SEE NOTE 2 SMK/EMG BC1 L1 T1 L2 T2 COM1 RL1 RL2 COM2 RL RL4 RL5 RL6 RL7 RL8 COM-8 COM-8 AO1 AO2 AO AO4 + High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. CM 2 2 C C TR1 TR2 24V 24V PK L T PK CFC RF C HEATER PLF 1 L2 T2 SEE NOTE 4 24V TB1 DAT AI1 AI2 AI AI4 AI5 AI6 24 VAC AI7 VOUT DC AI8 A A 24VAC PK C F EXF RVC CHS L1 T1 T1 T2 T T4 SEE NOTE 5 T5 CS PS ES XS OAT C AG TB2 + HH + ALRM // L06609-A OARH TEMP STPT OFFSET VOUT DC SPCRH SPCTEMP VOUT DC 24VAC COM /PK HPS LPS / / LPS PK PK BPSW DA OUT PHASE MONIT L1 L2 L L1 T1 L2 T2 L T L T BC2 L1 T1 L2 T ECON 6 COMP CS EM GY SEE NOTE 6 Y Y C CO SS-DCH6

21 Wiring Diagram with DDC DCH072***(208-20//60)V*** SEE NOTE 4 208/240//60 208/240// TR TR 24V 24V SEE NOTE 5 SMK/EMG BPSW LPS HPS BI1 BI2 COM1 BI RL1 CS BI4 RL2 DAT OAT OARH CO2 SENS SPC OFFSET TEMP COM SPCRH RSS LDS CFS DFT BI5 BI6 BI7 BI8 AI1 AI2 AI AI4 AI5 AI6 AI7 AI8 A COM2 RL DDC RL4 RL5 RL6 RL7 RL8 COM-8 AO1 AO2 AO AO4 BC2 BC1 CFC RVC + HH + EXF ALRM 24VAC ECON PLF HEATER PLF Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. COMPONENT LEGEND NOTES: 1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS IGINAL (AT LEAST 105 C) USE COPPER CONDUCT ONLY. 2. USE COPPER CONDUCTS ONLY ++ USE N.E.C. CLASS 2 WIRE. ECONOMIZER PLUG LOCATED IN THE RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO THE ECONOMIZER AESSY. 4. F 208 VOLT TRANSFMER OPERATION MOVE ACK WIRE FROM TERMINAL TO TERMINAL 2 ON TRANSFMER. 5. REMOVE JUMPER IF SMOKE DETECT/EMERGENCY SHUTDOWN PHASE MONIT DEVICE IS INSTALLED. 6. CRANKCASE HEATER AND CRANKCASE HEATER SWITCH FACTY EQUIPPED EN REQUIRED. SEE UNIT RATING PLATE F TYPE AND SIZE OF OVER CURRENT PROTECTION High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. FACTY WIRING LINE VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE OPTIONAL LOW VOLTAGE WIRE CODE ACK UE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE OWN EEN ANGE PK PINK RPLE RED ITE YELLOW /PK UE WITH PINK STRIP /PK YELLOW WITH PINK STRIP SCHEMATIC SYMBOL FIELD OUND FIELD SPLICE IGNITER INTERNAL TO INTEATED CONTROL JUNCTION OVERCURRENT PROT. DEVICE PLUG CONNECTION SWITCH (PRESS.) SWITCH (TEMP) TERMINAL // L06610-A A AO AI ALRM BC1 BC2 BI BPSW CFC CFS CH CHS CM COM COMP CS DFT ECON EM ES EXF HH HPS LDS LPS OAT OARH PLF PM PS RF RL RSS RVC SAT/DAT SD SMK/EMG SPCTEMP SPCRH TB1-2 TB1-T TR1-2 XS DC OUND F ANALOG SENSS ("AG" ON TB2) 4 ANALOG OUTTS 8 ANALOG INTS ALARM OWER HIGH SPEED CONTACT OWER LOW SPEED CONTACT 8 BINARY INTS OWER PROVING SWITCH COMPRESS CONTACT CONDENSER FAN COIL CLOGGED FILTER SWITCH CRANKCASE HEATER CRANKCASE HEATER SWITCH CONDENSER MOT COMMON ("C" ON TB2) COMPRESS COMPRESS 2ND STAGE SOLENOID DEFROST THERMOSTAT ECONOMIZER EVAPAT MOT ECON COM-8 AND SMOKE DETECT EXHAUST FAN EQUIPMENT OUND HOT GAS REHEAT HIGH PRESSURE SWITCH LOAD SHEDDING LOW PRESSURE SWITCH OUTDO AIR TEMPERATURE OUTDO AIR RELATIVE HUMIDITY FEMALE PLUG / CONNECT PHASE MONIT PRESSURE SWITCH RUN CAPACIT F CONDENSER FAN RELAY REMOTE START STOP REVERSING VALVE COIL SUPPLY / DISCHARGE AIR TEMPERATURE SMOKE DETECT SMOKE EMERGENCY SHUTDOWN SPACE TEMPERATURE SPACE RELATIVE HUMIDITY TERMINAL OCK (24V SIGNAL) PHASE MONIT TERMINAL OCK (PM) TRANSFMER 24 VAC TRANSFMER & SMOKE DETECT L1 SEE NOTE 2 SUPPLY VOLTAGE V//60 T1 COMP T2 T L2 L C F RF SEE NOTE 6 CM CHS CH BC1 BC2 BC2 BC1 EM BC2 BC1 SS-DCH6 21

22 Wiring Diagram with DDC DCH072***(460, 575//60)V*** 1 C TR1 24V C 460 TR2 24V SEE NOTE 7 SMK/EMG BC2 SEE NOTE 8 L T DFT /PK RSS LDS CFS PK BI1 BI2 BI BI4 BI5 BI6 BI7 COM1 RL1 RL2 COM2 RL RL4 RL5 RL6 RL7 RL8 COM-8 COM-8 AO1 AO2 AO AO4 PK + HH + EXF ALRM HEATER PLF POWER SUPPLY 460/575//60 SEE NOTE 4,5 L2 C L1 L L2 C L1 RVC T1 CFC RF L2 T2 C F C L1 T2 T1 BC1 T T2 T1 CH CHR COMP EM CM CHS SEE NOTE 9 Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death DAT OAT 24V T1 T2 T T4 T5 CS PS ES XS DA PK PK /PK 24 VAC VOUT DC TB1 C AG BPSW HPS LPS / / LPS PK PK BI8 AI1 AI2 AI AI4 AI5 AI6 AI7 AI8 A A 24VAC PK SPCRH OARH TEMP STPT OFFSET SPCTEMP 24VAC VOUT DC // L06621-A CO2 VOUT DC COM Y OUT L1 L2 Y PHASE MONIT C L L T L2 C T2 GY L1 T ECON 6 SEE NOTE 6 PK CS 22 SS-DCH6

23 Wiring Diagram with DDC DCH072***(460, 575//60)V*** L1 HPS T1 ECON PLF COMP SEE NOTE 2 SUPPLY VOLTAGE //60 T2 460/575//60 BPSW 1 4 RSS LDS CFS DFT 2 1 LPS RF 24V BI1 BI2 BI BI4 BI5 BI6 BI7 BI8 AI1 AI2 AI AI4 AI5 AI6 AI7 AI8 A 24VAC T CM DDC TR COM1 RL1 RL2 COM2 RL RL4 RL5 RL6 RL7 RL8 COM-8 AO1 AO2 AO AO4 1 L2 2 2 CHS 24V SMK/EMG HEATER PLF 460/575//60 TR CHR CS BC2 BC1 CFC RVC NOTES: COMPONENT LEGEND 1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS IGINAL (AT LEAST 105 C) USE COPPER CONDUCT ONLY. 2. USE COPPER CONDUCTS ONLY ++ USE N.E.C. CLASS 2 WIRE. ECONOMIZER PLUG LOCATED IN THE RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO THE ECONOMIZER AESSY. 4. F 460 VOLT TRANSFMER OPERATION MOVE ACK WIRE FROM TERMINAL TO TERMINAL 2 ON TRANSFMER. 5. REMOVE JUMPER IF SMOKE DETECT/EMERGENCY SHUTDOWN DEVICE PHASE MONIT IS INSTALLED. 6. CRANKCASE HEATER AND CRANKCASE HEATER SWITCH FACTY EQUIPPED EN REQUIRED. Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. FACTY WIRING WIRE CODE ACK UE LINE VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE OPTIONAL LOW VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE OWN EEN ANGE PK PINK RPLE RED ITE YELLOW /PK UE WITH PINK STRIP /PK YELLOW WITH PINK STRIP SCHEMATIC SYMBOL FIELD OUND FIELD SPLICE IGNITER INTERNAL TO INTEATED CONTROL JUNCTION OVERCURRENT PROT. DEVICE PLUG CONNECTION SWITCH (PRESS.) SWITCH (TEMP) TERMINAL SEE UNIT RATING PLATE F TYPE AND SIZE OF OVER CURRENT PROTECTION // L A A AO AI ALRM BC1 BC2 BI BPSW CFS CH CHR CHS CM COM COMP DFT ECON EM ES EXF HH HPS LDS LPS OAT OARH PLF PS RF RL RSS RVC SAT/DAT SMK/EMG SPCTEMP SPCRH T1-T5 TB1-2 TR1-2 XS SD CS CFC TB1-T PM DC OUND F ANALOG SENSS ("AG" ON TB2) 4 ANALOG OUTTS 8 ANALOG INTS ALARM HIGH SPEED CONTACT LOW SPEED CONTACT 8 BINARY INTS OWER PROVING SWITCH COMPRESS CONTACT CLOGGED FILTER SWITCH CRANKCASE HEATER CRANKCASE HEATER RELAY CRANKCASE HEATER SWITCH CONDENSER MOT COMMON ("C" ON TB2) COMPRESS DEFROST THERMOSTAT ECONOMIZER EVAPAT MOT ECON COM-8 AND SMOKE DETECT EXHAUST FAN EQUIPMENT OUND HOT GAS REHEAT HIGH PRESSURE SWITCH LOAD SHEDDING LOW PRESSURE SWITCH OUTDO AIR TEMPERATURE OUTDO AIR RELATIVE HUMIDITY FEMALE PLUG / CONNECT PRESSURE SWITCH RUN CAPACIT F CONDENSER FAN RELAY REMOTE START STOP REVERSING VALVE COIL SUPPLY / DISCHARGE AIR TEMPERATURE SMOKE EMERGENCY SHUTDOWN SPACE TEMPERATURE SPACE RELATIVE HUMIDITY MOT SPEED TAPS 1-5 (DRTECT DRIVEN MOT ONLY TERMINAL OCK (24V SIGNAL) TRANSFMER 24 VAC TRANSFMER & SMOKE DETECT SMOKE DETECT COMPRESS 2ND STAGE SOLENOID CONDENSER FAN COIL PHASE MONIT TERMINAL (PM) PHASE MONIT 1 OARH CO2 SENS SPC OFFSET TEMP COM SPCRH DAT OAT C F SEE NOTE 4 SD PM + HH + EXF ALRM L SEE NOTE 6 SEE NOTE VM BC1 BC1 BC1 VMR EM BC2 BC2 BC2 SS-DCH6 2

24 Accessories Daikin Master Item # Curb Description Fits Model Sizes Field- Installed Factory- Installed Operating Weight (lbs) 14CURB672B 14 Roof Curb -6 tons 86 18CURB672B 18 Roof Curb -6 tons CURB672B 24 Roof Curb -6 tons 128 GHRC-672 Hurricane Restraint Clips -6 tons 2 Ultra Low-Leak Economizer & Power Exhaust C Ultra Low-Leak Downflow Economizer w/ Enthalpy -6 tons Ultra Low-Leak Horizontal Economizer w/ Enthalpy -6 tons Prop Power Exhaust 20v -6 tons Prop Power Exhaust 460v -6 tons Prop Power Exhaust 575v -6 tons 55 Low-Leak Economizer & Power Exhaust2 DDNECNJ672C Low-Leak Downflow Economizer -6 tons 82 DPE6722 Downflow Power Exhaust (208/20 Volt) -6 tons 55 DPE6724 Downflow Power Exhaust (460 Volt) -6 tons 55 DPE6727 Downflow Power Exhaust (575v) -6 tons 55 DINHZ672B Horizontal Economizer, Internally Mounted -5 tons 90 DHZECNJ672 Horizontal Economizer -6 tons 70 DHPE6722 Horizontal Power Exhaust (208/20 Volt) -6 tons 55 DHPE6724 Horizontal Power Exhaust (460 Volt) -6 tons 55 DHPE6727 Horizontal Power Exhaust (575 Volt) -6 tons 55 Downflow Accessories D25FD672 25% Manual Fresh Air Damper -6 tons 12 D25MFD672 25% Motorized Fresh Air Damper -6 tons 16 DDNBBS672 Burglar Bar Sleeves with Supply & Return -6 tons 0 DDNECNJ672NR Downflow Economizer2 w/o Barometric Relief -6 Tons 77 DDNSQ Downflow Square-to-Round Adapter (18 Round) 4-6 tons 5 Horizontal Accessories DB672 Barometric Relief Damper -6 tons 15 Concentrics CDK4872 Concentric Duct Kit 4-6 tons 27 DDC Accessories DDC communicating controller (built-in BACnet MS/TP) includes Standard Room Sensor to -6 tons 2 be installed in field 1066D09C DDC Ultra Low-Leak Downflow Economizer -6 tons D09 DDC Ultra Low-Leak Horizontal Economizer -6 tons DDC Power Exhaust kit used with DDC Ultra Low-Leak Economizer -6 tons 1 DLAKT01 Low-Ambient -6 tons SS-DCH6

25 Accessories Daikin Master Item # Description Fits Model Sizes Field- Installed Factory- Installed Operating Weight (lbs) LONKT01 LonWorks card -6 tons 1 PMK01 Phase Monitor (-Phase Only) -6 tons 2 DFSKT01 Dirty Filter Switch -6 tons 1 phase V Electric Heat Kits SPKT02 Single Point Wiring Kit phase Heat Kits -6 tons EHK-10 10kw ph Electric Heat Kit -6 tons 21 EHK-15 15kw ph Electric Heat Kit -6 tons 21 EHK-25 25kw ph Electric Heat Kit 6 tons 21 phase 460V Electric Heat Kits EHK kw 460v ph Electric Heat Kit -6 tons 21 EHK kw 460v ph Electric Heat Kit -6 tons 21 EHK kw 460v ph Electric Heat Kit 6 tons 21 phase 575V Electric Heat Kits EHK kw 575v ph Electric Heat Kit -6 tons 21 EHK kw 575v ph Electric Heat Kit -6 tons 21 EHK kw 575v ph Electric Heat Kit 6 tons 21 High-Static Kits HSKTW072FI High-Static Kit (20/460/575v) 6 tons 15 Crankcase Heater Kits 010L00017S 70W 20V 4-6 tons 1 010L00018S 70W 460V 4-6 tons 1 010L00019S 70W 575V 4-6 tons 1 High Efficiency Filters 0160L00205 High Efficiency MERV 1 Air Filter Nom. Size: 16x20x2; (Order Qty 4) 5 & 6 tons 4 Misc Accessories HAILGD04D Condenser Coil Hail Guard 6 tons 22 Convenience Outlet: Non Powered -6 tons 2 Convenience Outlet: Powered -6 tons 42 Disconnect Switch -6 tons 5 LAKT12 Low Ambient Kit, V - non-ddc -6 tons 14 LAKT15 Low Ambient Kit, 460V - non-ddc -6 tons 14 LAKT16 Low Ambient Kit, 575V - non-ddc -6 tons 14 PMNDK01 Phase Monitor - Non DDC -6 tons 2 Smoke Detector (supply and/or return air) -6 tons 11 Hinged Panels -6 tons 10 1 Use Economizer & Power Exhaust listed within Ultra Low-Leak section 2 Use Economizer & Power Exhaust listed within Low-Leak section For a full list of DDC accessories, please refer to DDC Controller Technical Guide manual (DK-DDC-TGD-01B) Note: Where multiple variations are available, the heaviest combination is listed. SS-DCH6 25

DSC Series. Submittal Data Form. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER

DSC Series. Submittal Data Form. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER DSC Series Submittal Data Form 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: Standard

More information

DCG Commercial. Submittal Data Form

DCG Commercial. Submittal Data Form DCG Commercial Submittal Data Form 15-25 Tons Packaged Gas / Electric Units 15 Tons Cooling Capacity: 180,000 BTU/h 20 Tons Cooling Capacity: 240,000 BTU/h 25 Tons Cooling Capacity: 290,000 BTU/h 15 Tons

More information

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

More information

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: DCC Commercial 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling

More information

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan Submittal Data Form Job Name DCC Series 3-6 Ton Packaged Air Conditioner 13 SEER / Up to 11.3 EER 6-Ton with Two-Speed Blower Motor and Two-Stage Compressor Up to 15.5 IEER Cooling Capacity: 34,600 71,000

More information

ARPT Series. Multi-Position, Multi-speed Air Handler with Internal TXV and PSC Motor 2 to 5 Tons. Contents. Product Features

ARPT Series. Multi-Position, Multi-speed Air Handler with Internal TXV and PSC Motor 2 to 5 Tons. Contents. Product Features Series Multi-Position, Multi-speed Air Handler with Internal TXV and PSC Motor to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... 4 Airflow

More information

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

More information

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan DTC Series 3-5 Tons Packaged Air Conditioner Up to 15.5 SEER / Up to 13.0 EER Cooling Capacity: 35,600 60,000 BTU/h Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation

More information

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER DCC Series Submittal Data Form Job Name 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By:

More information

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features Series Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV ½ to Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... Airflow Data...

More information

ARPT Series. Multi-Position. 2 to 5 Tons. Internal TXV, Multi-Speed PSC Motor

ARPT Series. Multi-Position. 2 to 5 Tons. Internal TXV, Multi-Speed PSC Motor Contents Air Handler Nomenclature... Heater Kit Nomenclature...... Dimensions...4 Airflow Data...5 Heat Kit Data...6 Wiring Diagram... Accessories... Product Features Internal factory-installed thermal

More information

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners DCG Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant

More information

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features Series Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV ½ to Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... Airflow Data...

More information

ARPT Series. Multi-Position. 1½ to 5 Tons. Internal TXV, Multi-Speed PSC Motor

ARPT Series. Multi-Position. 1½ to 5 Tons. Internal TXV, Multi-Speed PSC Motor Contents Nomenclature... 2 Accessories... 2... 3 Dimensions... 4 Airflow Data... 5 Heat Kit Data... 6 Wiring Diagram... 8 Series Product Features Internal factory-installed thermal expansion valves for

More information

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges. Service Literature The LGH/LCH high and standard efficiency 5, 0, 5 and 50 ton (, 0.7, 58. and 75.9 kw) units, are configure to order units (CTO) with a wide selection of factory installed options. The

More information

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons ASUF Series Multi-Position Multi-Speed ECM Based Product Features Check flowrator for cooling and heat pump applications Direct drive, multi-speed ECM blower motor All-aluminum evaporator coil Coil mounting

More information

MBR. Multi-Position. Modular Blower

MBR. Multi-Position. Modular Blower M Product Features Direct drive, multi-speed PSC blower motor kw 1 kw electric heat kits Blower section usable as electric heater Horizontal or vertical configuration capabilities 1" depth for easier attic

More information

ACNF Series. Ceiling-Mounted Air Handlers 1½ to 2½ Tons

ACNF Series. Ceiling-Mounted Air Handlers 1½ to 2½ Tons ACNF Series Ceiling-Mounted Air Handlers 1½ to 2½ Tons Contents Nomenclature...2 Heat Kit Data...2 Product Specifications...3 Dimensions...5 Airflow Data...5 Wiring Diagram...6 Accessories...8 Features

More information

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible 1½ to 5 Tons. Contents. Product Features

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible 1½ to 5 Tons. Contents. Product Features MBVC Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Airflow Data...

More information

AVPTC Multi-Position, Internal Txv

AVPTC Multi-Position, Internal Txv Multi-Position, Internal Txv Variable-Speed ECM Based Comfortnet Compatible Air Handler 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature...... Dimensions...4 Airflow Data...5 Heat

More information

MBR. Multi-Position, Multi-Speed Modular Blower With PSC Motor 1½ to 5 TONS. Contents. Product Features

MBR. Multi-Position, Multi-Speed Modular Blower With PSC Motor 1½ to 5 TONS. Contents. Product Features M Multi-Position, Multi-Speed Modular Blower With PSC Motor 1½ to 5 TONS Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... 4 Airflow Data... 5 Heat

More information

MBR. Multi-Position, Multi-Speed Modular Blower With PSC Motor. Contents. Product Features

MBR. Multi-Position, Multi-Speed Modular Blower With PSC Motor. Contents. Product Features M Multi-Position, Multi-Speed Modular Blower With PSC Motor Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... 4 Airflow Data... 5 Heat Kit Data...

More information

AVPTC Multi-Position, Internal Txv

AVPTC Multi-Position, Internal Txv Multi-Position, Internal Txv Variable-Speed ECM Based Comfortnet Compatible Air Handler 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature......3 Dimensions...4 Airflow Data...5

More information

AVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.

AVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... 3 Dimensions...

More information

DVPEC. Multi-Position, Variable-Speed air handler. Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons

DVPEC. Multi-Position, Variable-Speed air handler. Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons DVPEC Multi-Position, Variable-Speed air handler Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Airflow

More information

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13 Tag Data - Split System Air Conditioning Units (Large) (Qty: 6) Item Tag(s) Qty Description Model Number A1 20 ton vfd 6 6-25 Ton Unitary Split Systems ( SSC2 TTA24004H00-TWE240E404A TTA Air Condensing

More information

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons 007-014 Single- Package Rooftop Units - 50 Hz 6 to 12 Nominal Tons Product Data Single package rooftop cooling units with electric heat option. Compact, horizontal discharge units (vertical discharge option),

More information

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV DVPVC Multi-Position, Variable-Speed Air Handler Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications...3

More information

Multi-Path RTU-TYPE 2

Multi-Path RTU-TYPE 2 ALDI # CITY, STATE SUPERMARKET MultiPath RTUTYPE 2 (RTU1) CESMPU025RHVAV2 Date: February 17, 201 2013 Consolidated Energy Solutions, Inc. UNIT FEATURES CES TYPE VAV2 Unit features include: 25 Ton MultiPath

More information

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT PGF SERIES 7-1/2 Ton C Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT SINGLE PACKAGE Combination gas heating and electric cooling, self contained for year-round comfort. Systems can be installed

More information

WPH4 Product Specifications

WPH4 Product Specifications Up to 14.5 SEER, 8.0 HSPF PACKAGE HEAT PUMP 2 to 5 TONS Single Phase, 208/230 V, 60 Hz Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification

More information

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION PRODUCT SPECIFICATIONS PACKAGED HEAT PUMPS 3HPP / rhp3 Rooftop Units 60HZ Bulletin No. 0634 October 04 Supersedes October 0 MODEL NUMBER IDENTIFICATION -PHASE MODELS Nominal SEER (3HPP Shown) Unit Type

More information

RGE 13 A T - 1 A

RGE 13 A T - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE

More information

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons Product Data 50HS Single-Package Heat Pumps 1 1 2 to 5 Nominal Tons Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece heat pumps with optional

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop, High---Efficiency Heat Pump Units With Field---Installed Electric Heat Sizes 08 --- 14 with Puron R (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz) DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage

More information

Product Data. Fig. 1 - Unit 50VR -A

Product Data. Fig. 1 - Unit 50VR -A 50VR---A Performancet 15 SEER 2---Stage Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VR -A A09033 Single-Packaged

More information

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible. Contents. Product Features

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible. Contents. Product Features Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible Contents MBVC Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Airflow Data... Heat Kit Data...

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS AutoZone R Model Single Package Rooftop Gas Heating/Electric Cooling Unit Size 07 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION

More information

PAJ3. Product Specifications

PAJ3. Product Specifications 13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,

More information

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM EFFICIENT UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase REFRIGERATION CIRCUIT S 2- stage scroll compressors

More information

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON 7D- -A EVOLUTIONr 15 SEER SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONr (R-410A) REFRIGERANT SINGLE PHASE 2-5 NOMINAL TONS (SIZES 24-) Fig. 1 - Unit 7D - -A Product Data A09032 Single-Packaged Products

More information

AVPTC Multi-Position, Internal Txv

AVPTC Multi-Position, Internal Txv Product Features Internal factory-installed thermal expansion valves for cooling and heat pump applications Variable-speed ECM blower motor ComfortNet Communicating System compatible Auto configuration

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop Gas Heating/Electric Cooling Unit Two Stage Cooling Capacity Control with Puronr (R---410A) Refrigerant Sizes: 17, 20, 24, 28, 30 Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION

More information

48PGD/E/F/L/M/N PG20-28

48PGD/E/F/L/M/N PG20-28 48/50PG-10SB 48PGD/E/F/L/M/N20-28 50PG20-28 SINGLE-PACKAGE COOLING UNITS WITH FACTORY-INSTALLED GAS HEAT SINGLE-PACKAGE COOLING UNITS WITH OPTIONAL ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINTS

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT: GENERAL SPECIFICATIONS OUTDOOR UNIT: TECHNICAL GUIDE COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM MODELS HB 180 & HB 240 MODELS LB 180 & LB 240 15 & 20 NOMINAL TONS 9.7 EER Two independent refrigerant

More information

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units TECHNICAL SPECIFICATIONS R7DA Series 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units 5.4 ISMRE Commercial System 81% Steady State Efficiency Standard Features Fits Pre-Existing Curbs High-Efficiency Low

More information

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS SECTION 15732 - PACKAGED ROOFTOP AIR CONDITIONING UNITS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Package roof top unit. B. Heat exchanger. C. Refrigeration components. D. Unit operating controls. E. Roof

More information

High Heat COP. High/Low Stage

High Heat COP. High/Low Stage SOUND REFRIGERANT ENVIRONMENTALLY PHN5 Product Specifications 15 SEER, 8.0 HSPF, PACKAGE HEAT PUMP, 2-5 TONS Single Phase, 208/230V, Hz. REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum fin

More information

ASUF Series. Multi-Position, Multi-Speed ECM-Based Air Handler 1½ to 5 Tons. Contents. Product Features

ASUF Series. Multi-Position, Multi-Speed ECM-Based Air Handler 1½ to 5 Tons. Contents. Product Features ASUF Series Multi-Position, Multi-Speed EM-Based Air Handler ½ to Tons ontents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... Heat Kit Data... Wiring Diagram...

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

AVPTC. Air Handlers 1½ to 5 Tons

AVPTC. Air Handlers 1½ to 5 Tons Multi-Position, Variable-Speed Air Handlers ½ to Tons Standard Features Compatible with the ComfortNet Communicating System family of products R-0A refrigerant-compatible Factory-installed thermal expansion

More information

PAR5. Product Specifications

PAR5. Product Specifications TM PAR5 Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE AIR CONDITIONING UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced

More information

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons Product Features Check flowrator for cooling and heat pump applications Direct drive, multi-speed ECM blower motor All-aluminum evaporator coil Coil mounting track for quick repositioning Optimized for

More information

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat SINGLE PACKAGE ROOFTOP, GAS HEATING/ELECTRIC COOLING UNIT WITH PURON R (R-410A) REFRIGERANT ONE STAGE COOLING CAPACITY CONTROL: SIZES 08-12 TWO STAGE COOLING CAPACITY CONTROL: SIZES 08, 12 & 14 Submittal

More information

VariCool VAV Engineering Guide

VariCool VAV Engineering Guide Engineering Guide Effective September 2017 Water-Cooled and Chilled Water, Variable Air Volume Contents Product Features... 3 UNIT FEATURES... 3 Product Features... 4 Marvel Plus Microprocessor Control

More information

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer SUBMITTAL Project CLU Swenson Center Date 01/07/2010 Mechanical Contractor West Coast Air Conditioning Mechanical Engineer J & S Consulting Engineers, Inc. Revision Notes RTU-101, 102, 103, 201, 202, 203,

More information

Roof Top Packaged Unit (RTU-1) Specification

Roof Top Packaged Unit (RTU-1) Specification Roof Top Packaged Unit (RTU-1) Specification Item Tag(s) Qty Description Model Number A2 10 Ton 1 10 Ton R410A PKGD Unitary Gas/Electric TRANE: YHC120F3RLA--07C1 Product Data - 10 Ton R410A PKGD Unitary

More information

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAJ4 Product Specifications UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R-410A

More information

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(HE, HG) 036, 048 & YTG-A-0506

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(HE, HG) 036, 048 & YTG-A-0506 TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(HE, HG) 036, 048 & 060 3, 4 & 5 NOMINAL TONS 12.2 THROUGH 13.2 SEER DESCRIPTION YORK Sunline Ultra units are convertible

More information

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving Product Data ROOMTOP 50AH024-096 Standard Efficiency Horizontal Indoor Single-Package Cooling Units with PURON Refrigerant (R-410A) 2 to 8 Nominal Tons The 50AH single-package cooling units feature: ASHRAE

More information

PACKAGE AIR CONDITIONER

PACKAGE AIR CONDITIONER PACKAGE AIR CONDITIONER FORM NO. ATZ-206 TZAA- HIGH EFFICIENCY SERIES NOMINAL SIZE 10 TON [35.2 kw] 10 TON MODEL [35.2 kw] This product is shipped with a nitrogen holding charge that must be vented prior

More information

STANDARD EFFICIENCY PACKAGE A/C UNIT to 216 MBtuh

STANDARD EFFICIENCY PACKAGE A/C UNIT to 216 MBtuh PAS Product Specifications STANDARD EFFICIENCY PACKAGE A/C UNIT - 74 to 26 MBtuh REFRIGERATION CIRCUIT All models are equipped with high efficiency scroll compressor on each circuit. Dual, electrically

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON

More information

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING SOUND REFRIGERANT ENVIRONMENTALLY PAN5 Product Specifications 15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R--410A refrigerant

More information

50VT--C Comfort 14 SEER Single--Packaged Heat Pump System with Puron

50VT--C Comfort 14 SEER Single--Packaged Heat Pump System with Puron 50VT---C Comfortt 14 SEER Single---Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single Phase 2 --- 5 Nominal Tons (Sizes 24 --- 60) Three Phase 3 --- 5 Nominal Tons (Sizes 36 --- 60) Product

More information

PHD3. Product Specifications

PHD3. Product Specifications SOUND REFRIGERANT ENVIRONMENTALLY PHD3 Product Specifications 13 SEER, 7.7 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant

More information

TECHNICAL MANUAL. ARPT**14**, ARUF**14**, ASPT**14**, ASUF**14** Air Handlers

TECHNICAL MANUAL. ARPT**14**, ARUF**14**, ASPT**14**, ASUF**14** Air Handlers TECHNICAL MANUAL AL ARPT**4**, ARUF**4**, ASPT**4**, ASUF**4** Air Handlers Refer to Service Manual RS600006 for installation, operation & troubleshooting information. All safety information must be followed

More information

62DA,DB,DC,DD,DE,DF07-38

62DA,DB,DC,DD,DE,DF07-38 62D-3SB 62DA,DB,DC,DD,DE,DF07-38 DEDICATED VERTICAL OR HORIZONTAL 100% OUTDOOR AIR UNIT PERFORMANCE DATA UNIT DIMENSION PRINTS ACCESSORY DIMENSION PRINTS Copyright 2011 Carrier Corporation Syracuse, New

More information

13 GEP A L P - 1 A

13 GEP A L P - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP MERIT SERIES Residential - R-40A Bulletin No. 20602 December 202 Supersedes October 202 SEER - 3.00 AFUE - 80% 2 to 5 Tons Cooling Capacity - 22,800

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop Gas Heating/Electric Cooling Unit Two Stage Cooling Capacity Control with NOVATIONt Coil Sizes 08, 12, 14 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED

More information

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS 16 SEER / R-410A HIGH-EFFICIENCY 2- TO 5-TON SPLIT SYSTEM AIR CONDITIONER COOLING CAPACITY: 24,000 BTU/H TO 57,000 BTU/H The Goodman 16 SEER Air Conditioner uses the environmentally friendly refrigerant

More information

14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS 208/ , Single Phase

14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS 208/ , Single Phase SOUND REFRIGERANT ENVIRONMENTALLY PHD4 Product Specifications 14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS 208/230 1 60, Single Phase REFRIGERATION CIRCUIT Environmentally sound R-410A refrigerant

More information

VertiCool Aurora Engineering Guide

VertiCool Aurora Engineering Guide Engineering Guide Effective August 2016 Air-Cooled, Water-Cooled and Water Source Heat Pump Contents Product Features... 3 Options... 4 Physical Data...5-6 Air-Cooled Performance Data (a) (b) (c)...7-8

More information

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE Service Facts Customer Property: Contains wiring and service information. Please retain. WC*240-SF-1H Library Service Literature Product Section Unitary Product Package Air Conditioner Model WC* Literature

More information

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units TECHNICAL SPECIFICATIONS P8SE Series 14 SEER, Single Phase Packaged Air Conditioner 3, 4, 5 Ton Units The P8 Series single packaged air conditioners are high efficiency self contained cooling units that

More information

REPLACEMENT PARTS LIST

REPLACEMENT PARTS LIST REPLACEMENT PARTS LIST PACKAGED GAS HEATING/ELECTRIC COOLING R7TQ SERIES 6-, 7.5-, AND 10-TON, 81% STEADY STATE EFFICIENCY IMPORTANT This document is primarily intended to assist qualified individuals

More information

R4H4. Product Specifications

R4H4. Product Specifications R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Scroll compressors on

More information

Product Data. Fig. 1 - Unit 50VG -A

Product Data. Fig. 1 - Unit 50VG -A 50VG---A Performancet 16 SEER 2---Stage Packaged Air Conditioner tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VG -A A09033 Single-Packaged

More information

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz Product Data 50HS Single-Package Heat Pump Units 50 Hz Nominal: 7 to 18 kw (2 to 5 Tons) Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece

More information

Ruud Commercial Achiever Series Package Gas Electric Unit

Ruud Commercial Achiever Series Package Gas Electric Unit Package Gas Electric Ruud Commercial Achiever Series Package Gas Electric Unit RKPN- 14 SEER Series RKQN- 15 SEER Series Nominal Sizes 3-5 Tons [10.6-17.6 kw] (15 SEER/12.0 EER AND ABOVE ONLY) Proper sizing

More information

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz ENVIRONMENTALLY SOUND REFRIGERANT N4H4 Performance Series Product Specifications 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

Submittal Summary Page

Submittal Summary Page ate 05/24/2011 Project Name ouglas Middle School Project Number Client / Purchaser Submittal Summary Page Qty Tag # Model # escription 1 RTU- Cafeteria 15 Ton, Johnson Controls Series 20 Single Packaged

More information

Corp L2 Revised

Corp L2 Revised Service Literature Corp. 08-L Revised 0-07 ZCA & ZCB SERIES, 4, 5 and 6 ton 0.6 to.kw ZCA06, 048, 060, 07 & ZCB06, 048, 060, 074 The ZCA packaged electric cooling units are available in standard cooling

More information

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw) FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz

More information

WJH4 Product Specifications

WJH4 Product Specifications UP TO 14.5 SEER, R 410A PACKAGE HEAT PUMP FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz Use of the AHRI Certified TM Mark indicates a

More information

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAD3 Product Specifications 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant

More information

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

CATALOG. SKYPAK Self-Contained Heating/Cooling Units CATALOG SKYPAK Self-Contained Heating/Cooling Units FORM SK145.00-EG6 (1211) TABLE OF CONTENTS SKYPAK Self-Contained Heating/Cooling Units Introduction...3 Product Overview...3 Nomenclature...4 SKYPAK

More information

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons 0TJ06-03S Side Discharge Single-Package Rooftop Units 0/ Hz to 30 Nominal Tons Product Data The 0TJ-S series is a special side discharge version packaged unit with capacities of -30 Tons. This unit can

More information

Product Data. Fig. 1 - Unit 50EZ -A

Product Data. Fig. 1 - Unit 50EZ -A 50EZ---A Comfortt 13 SEER Single---Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50EZ -A A09034 Single-Packaged

More information

AVPTC. Air Handler 1½ to 5 Tons

AVPTC. Air Handler 1½ to 5 Tons Multi-Position, Variable-Speed Air Handler ½ to 5 Tons Standard Features Compatible with the ComfortNet Communicating System family of products Maximum four low-voltage wires required for operation in

More information

Advance Release September 2009

Advance Release September 2009 Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*

More information

ADDENDUM 1. Southeast High School Auditorium & Gymnasium HVAC Improvements

ADDENDUM 1. Southeast High School Auditorium & Gymnasium HVAC Improvements ADDENDUM 1 CLIENT: PROJECT: TO: FROM: Guilford County Schools (GCS) Southeast High School Auditorium & Gymnasium HVAC Improvements All Prospective Bidders Derrick Giles, SAMR, PLLC. DATE: 6/6/2018 The

More information

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h / Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE Heating Input: 40,000 120,000 BTU/h Contents Nomenclature...2 Product Specifications...3 Dimensions...5 Airflow Specifications...7 Wiring Diagram...10

More information

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler Technical Development Program COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Introduction System

More information

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE Heating Input: 60,000 100,000 BTU/h Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Airflow Data... 5 Wiring Diagram...

More information

MODELS B1PA024, 030 AND 036

MODELS B1PA024, 030 AND 036 STELLAR 2000 SINGLE PACKAGE HEAT PUMPS INSTALLATION INSTRUCTION Supersedes: 511.26-N1Y (892) 511.26-N1Y (893) MODELS B1PA024, 030 AND 036 035-11622 GENERAL YORK Model B1PA units are factory assembled heat

More information

ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT MBtuh

ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT MBtuh PAE Product Specifications ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT - 278 MBtuh REFRIGERATION CIRCUIT All models are equipped with high efficiency scroll compressor on each circuit. Dual, Electrically

More information