APPLICATION GUIDE FOR OPTIVENT ULTRA

Size: px
Start display at page:

Download "APPLICATION GUIDE FOR OPTIVENT ULTRA"

Transcription

1 AIR MANAGEMENT APPLICATION GUIDE FOR» INNOVATIVE VAV DAMPER WITH ULTRASOUND TECHNOLOGY

2 UltraSound Technology by FläktGroup LOW NOISE GOOD INDOOR AIR QUALITY FLEXIBILITY ACCURATE & VERSATILE ENERGY EFFICIENT MAINTENANCE FREE OUR ULTRASOUND INNOVATION Ultrasound is a natural technique used by bats and dolphins, for instance. It s an effective way to analyse what s around you without seeing or touching it. In our innovation we have adapted ultrasound to analyse what happens with the air flow inside a ventilation duct. Precise sensors and clever algorithms gives us a very detailed image of the air stream by studying how sound waves are affected by the moving air. 2

3 INNOVATIVE VAV DAMPER WITH ULTRASOUND BRINGS UNMATCHED BENEFITS TO A WIDE RANGE OF APPLICATIONS FläktGroup OPTIVENT is a trusted line of VAV dampers that have been optimized with the latest cutting-edge innovation. With advanced airflow analysis based on ultrasound technology we now present a new dawn for Demand Controlled Ventilation. A landmark innovation setting aside traditional challenges for VAV dampers; Noise, turbulence and pressure drops in the airflow. Dust buildup affecting measuring precision, contaminating the air and requiring maintance. also offers unique benefits for builders, property owners and construction companies in more aspects. It avoids traditional risks and disadvantages in VAV systems and leads to simplified design, installation and commisioning, bringing lowered life cycle costs and an unprecedented level of air comfort as well. OPTIVENT ULTRA by FLÄKTGROUP 3

4 OPTIVENT ULTRA AND DEMAND CONTROLLED VENTILATION FOR INDOOR AIR QUALITY & COMFORT Today we spend over 90% of our time indoors. In order to reduce energy consumption, buildings are becoming more airtight. This means well planned ventilation and indoor air quality is more important than ever before. Not just for comfort reasons, but also to enable us to perform to our best. To learn more at school, to get well sooner in hospital and to be more productive at work. A Demand Controlled Ventilation (DCV) system detects momentary demand on ventilation and adapts to provide what s needed no more, no less. Doing so requires precision and flexibility from both system and components. as Variable Air Volume damper fits at the heart of any DCV system, adding further comfort benefits to the installation. Improved indoor air quality positively affects productivity. Increasing fresh air rates from 12 l/s to 24 l/s per person, has shown to reduce short term sick leave by 35%. Doubling the outdoor air supply rate in classrooms (in a range from 3 to 9,5 l/s per person) would improve the performance speed by 8 14%. 4

5 26 l/s PRECISE AIR VOLUME The measuring precision of our Ultrasound technology means that exactly the correct amount of air is supplied at any given moment. Not less, impairing comfort or health. Not too much, causing draft and unneccesary energy consumption. LOW SOUND LEVELS The sensor free flow measurement causes no noise inducing turbulence. A low flow resistance also requires lower pressure, which also limits noise levels. 8 l/s VERSATILE Ultrasound technology has the big advantage of being without any physical sensor inside the air stream. That means less risk of dust build-up a big advantage in many applications. FLEXIBLE WORKING RANGE OPTIVENT is constructed for optimum performance, from a minimum flow with delicate control to a maximum without turbulence or pressure drop from measuring air flow. 65 l/s TEMPERATURE & CO 2 IN CONTROL Thermal comfort and low CO 2 levels are crucial demands on indoor air climate. A narrow comfortable range of only a couple of degrees C require precise control, while the demand for fresh air means that CO 2 level must be controlled carefully. HUMIDITY Well controlled humidity levels is a less noticed air quality requirement. Unbalances still causing comfort issues like irritation in eyes, nose and skin and secondary effects like static electricity. is perfect for good comfort because of longterm control precision in DCV and low noise levels. 5

6 SOLVING THE CHALLENGES OF DEMAND CONTROL VENTILATION WITHIN ENVIRONMENT, ECONOMY, INSTALLATION AND RELIABILITY Nearly zero-energy buildings are the future, but it s a very near future. All new buildings must meet the standard by 2020, public buildings already The solution for ventilation goes in the footprints of automatic lights, switching on when we enter a space and off when we leave it. As ventilation requires even more energy than lighting, it makes sense to only deliver costly treated air when we need it and, where we need it. And that s the goal of DCV, Demand Control Ventilation. Adapting the ventilation provided exactly to the momentary need is a clever thought. It requires some additional hardware, like sensors and dampers, and refined controls that manages the system. But the increased investment has a short payback-time, when large energysavings lowers costs longterm and at the same time benefits the environmental aspects. Demand controlled ventilation is therefore growing heavily year by year. At the same time the challenges for design, installation, commissioning and maintenance are increasing too. OPTIVENT ULTRA simplifies tasks for every stakeholder. Compact to install, easier to control is extremely neat to fit into buildings as it requires much less space than traditional dampers. The ultrasound technology measures the entire cross-section of the airstream, which makes it unsensitive to turbulence. It means that you no longer need safety distances around bends and T-pieces. A DCV system with VAV dampers can now easily be accomodated, also in existing buildings with limited space. is also an adaptable component in any DCV system, with Modbus communication as standard equipment. 6

7 Less energy costs, lower maintenance requirements PROBABILITY OF THE OCCUPANCY DCV TIME Example of classroom occupancy and energy savings Constant air volume (CAV) ENERGY SAVINGS AVOID EXCESS WITH DCV TO REACH THE GOALS Employing Demand Controlled Ventilation is a smart way to save energy. When you adapt the air supply to momentary demand, energy can be saved without any sacrifice. The trick is to sense demand in temperature and CO 2 -levels and adapt the ventilation. A simple task with smart controls - made even simpler with as VAV damper. AIR FLOW As part of a Demand Control Ventilation system, OPTIVENT ULTRA is contributing to a operating cost with sound figures. With ever growing energy prices the calculation done yesterday very quickly gets better and better for each passing day. But contributes to longterm economy also in it s own right: Measuring air flow in the system by means of ultrasound is more precise, which means less energy consuming air flow, heating and cooling is made in excess of demand. With the ultrasound measuring technology, no physical pressure sensor inside the air stream causes turbulence and pressure drops requiring higher fan drive. Traditional pressure sensors will over time collect dust. The dust build-up affects both precision and pressure drop, causing unneccesary energy costs. To avoid this, regular cleaning is required. Without physical sensors, ultrasound lowers this maintenance cost too. (And when ductwork is brushed for regular cleaning, ultrasound sensors are completely unaffected) Investment 10% Count on saving with Maintenance 5% A system for Demand Controlled Ventilation, based on dampers is a good choice made even better with the advantages of ultrasound taken into account. Energy 85% LCC SAVINGS vs. traditional VAV dampers COST INVESTMENT IS THE SMALL PART if you consider a typical ventilation system, where it constitutes only around 10% during it s life cycle. Trad. VAV damper with static meas. Trad. VAV damper Cooling 30% Lighting and tecnical installations 10% Trad. VAV damper with T-sensor Trad. VAV damper with static meas. Trad. VAV + T-sensor Trad. VAV damper LCC savings vs. traditional VAV dampers Extra design, installation and commissioning costs vs TIME LCC SUMS IT ALL UP. When you take into account all the costs during a VAV-dampers lifetime, is in it s own class; Lower investment than a VAV-damper with static measuring and lower design and commissioning costs than VAV-dampers with T-sensor. Compared to a simple, traditional VAV-damper it has only a small initial price disadvantage, very soon compensated by outstanding operating costs. Ventilation 30% Heating 30% ENERGY CONSUMPTION IN BUILDINGS is possible to address to a large extent with an efficient ventilation system, as much of the costs are affected by it. 7

8 Invisible technology for concrete benefits In the continous efforts to develop our products and solutions we have always tried to think outside the box. For control of VAV dampers this has taken a very concrete turn. We wanted to be able to measure the air flow, with precision, from outside of the air flow. We realised it would give us a number of substantial benefits, both in the basic performance of the unit and during long term use. After several years of development at our research centre in Finland we have realised the technology in a landmark innovation for VAV dampers with several patents pending. No physical Sensor inside the airstream that collects dust, induces noise or affects the airflow, leading to turbulence and pressure loss. With Ultrasound we can detect without causing unwanted effect The development of ultrasound technology for air flow measuring is derived from a couple of physical facts. Sound waves are sensitive detectors with limited effect on the subject, a property giving us clear images of unborn babies. But sound waves are also sensitive for air movement. Try for instance shouting against the wind. DETECTION METHOD When analysing air movement with ultrasound waves, several methods can be used. We have chosen to use a technique called beam drift. The basic physics we use, are sound waves radiating from a sound source. They are invisible, but behave the same way as the uniform circle of ripples on water around a dropped pebble. In the case of sound waves the circles will drift off with the wind. UltraSound Technology by FläktGroup 8

9 Ultrasound technology * means much more compact installations, requiring no extra safety distances around the Damper. Ultrasound technology * components transmit and receive ultrasound. The entire airstream is analysed with high accuracy in both low and high air speeds. Intelligent Controls sense temperature and analyse average air speed with carefully developed ultrasound algorithms, resulting in high precision data with long-term reliability. The control panel is easy to operate with an intuitive human-machine interface. Settings are simple to adjust and the digital display shows the current air flow in real-time. * Patented technology by FläktGroup WITH ULTRASOUND TECHNOLOGY AIR SPEED IS ZERO When air inside the duct isn t moving at all, the sound waves radiating from the transmitter are perfectly uniform. The twin sensors on the opposite wall will read the waves exactly at the same time, without any phase shift. AIR SPEED IS LOW When air moves at a low pace sound waves start drifting which can be observed by measuring the phase shift between the two receivers. As the entire cross-section of the air stream affects the waves, even small movements are registered correctly. AIR SPEED IS HIGH At full power the wave drift is larger, causing a larger phase shift being measured by the sensors. In this case a physical sensor inside the air stream would have caused a considerable pressure drop and with an obvious risk of turbulence causing undesired noise. 9

10 ADVANTAGES OVER TRADITIONAL TECHNOLOGY WITH ULTRASOUND FOR VAV DAMPERS IN DEMAND CONTROL VENTILATION SYSTEMS Demand Control Ventilation is generally considered as the way forward for ventilation, when environ- BIG Traditional VAV dampers mental regulations, rising energy prices and higher demands for health and comfort come into play. Ways to overcome problems with traditional VAV dampers are in the spotlight, and now addressed by with ultrasound technology. The advantages are clear, making it an interesting option in new installations. But several properties also are beneficial when retro-fitting into existing buildings. SMALL Air flow range Accuracy Influence of disturbances BEATS traditional VAV dampers in a series of important aspects. Influence of dust etc. Pressure drop of air flow meas. Noise SPACE SAVING REQUIREMENTS MAKES INSTALLATION SIMPLER requires no safety distances to bends and T-pieces, as ultrasound measures the entire air flow, which makes it resilient to turbulence. The space savings in a typical installation are substantial. is also the same dimension as the tubes and there is no need to convert for smaller dimensions as it covers a wider air flow range with optimum performance. 10

11 improvements WIDE AIRFLOW RANGE ACCURACY DISTURBANCE-SAFE With precise control over measurement and no sensors affecting the flow, OPTIVENT ULTRA covers a big range, from 0,5 m/s up to 15 m/s depending on size. Ultrasound measuring is extremely precise in the whole air flow range. At the smallest flow (0,5 m/s) accuracy is +/- 8%, improving to +/- 4% at higher velocities. Measuring flow with ultrasound increases resilience. Even with damper directly after T-piece or bend, the level of measuring precision is still good. WITHSTANDS DUST NO PRESSURE DROP LESS NOISE Without any pressure sensor inside the airflow, is not sensitive to dust, that can impair accuracy. Pressure drop for measuring air flow is zero with because there is no sensor in the airflow. This saves energy when fans need not compensate with increasing drive. Lower required system pressure and no turbulence around physical air flow sensors means noise is minimized and limits the need for space consuming silencers. surpasses traditional solutions in many fields and enables DCV in many buildings. LOW NOISE GOOD INDOOR AIR QUALITY FLEXIBILITY ACCURATE & VERSATILE ENERGY EFFICIENT MAINTENANCE FREE 11

12 THE DEMANDS MAY VARY BETWEEN APPLICATIONS BUT IS ALWAYS THE RIGHT CHOICE With a solid set of advantages compared to traditional solutions, is likely to make itself useful in a wide range of applications only on it s own merits. As part of a Demand Control Ventilation system it plays it s part with grace, making DCV possible and producing benefits for both economy and environment. 12

13 General Planning tips and checklist Checklist and planning tips for your configuration Min air flow in the room: Necessary fresh air flow for good air quality (10 l/s per person or acc. to floor area 0,5 (l/s)/m²) Max air flow in the room: According to the required cooling capacity calculation Specify min and max air for the working instructions. Suppy air ducts: Dimension according to the max air flow utilizing pressure regain method, or use a velocity of less than 4 m/s at the beginning of a branch with the rest of the duct having the same size. (Dimensioning tool e.g. MagiCAD) Minimize pressure drop of the ductwork by low air velocities which means energy savings, flexibility for the future changes and low noise and functional adjustment. Extract air ducts: Dimension according to the max air flow utilizing friction method (<1 Pa/m). Symmetrical ductwork keep air flow in designed values with different situations. When unsymmetric situation then use pressure control damper, EMPA. dimensioning: same size as duct, because air flow range is big (0,5 m/s 15 m/s in the duct). Select a silencer with the selection tool SELECT. Different air flows and pressure drop of the damper can be simulated. Check air pattern with SELECT in case of min and max air flow so that there is not problem with draught and ventilation efficiency. SELECT Select a silencer with the selection tool SELECT. Different air flows and pressure drop of the damper can be simulated. 13

14 GUIDE TO PLANNING/ DIMENSIONING/CONFIGURATION Nursery, Play/ Resting room Childrens activities in nurseries varies from intense play to after-lunch rest. A flexible solution is required to adapt to the varying demands. Nurseries also put tough demands on the health aspect due to childrens sensitivity and frequent dust, bacteria and virus contamination. Tight budgets should rather be spent on staff and toys than on unnecessary operating costs for the ventilation system. PLANNING TIPS / CHECKLIST: Min air flow in the room: 18 l/s (floor area 36 m²) Max air flow in the room: 100 l/s (loads=965 W and T=8 C) Supply air duct: ø 200mm (v=3,2 m/s with max air flow) Extract air duct: diameter 200 mm (0,65 Pa/m) : BDER for supply and extract (33 db(a) right after silencer with q=100 l/s and P=80Pa) Air pattern (diffuser RAOB-125): max air velocity 0,19 m/s in the occupational zone with minimum air flow and 0,19 m/s with maximum air flow. Set up of air throw length constant 1,5 m VAV Damper OPTIVENT ULTRA VAV Damper OPTIVENT ULTRA Room controller 2x Active supply diffuser 2x Exhaust diffuser CO 2 -sensor and Temperature sensor Occupancy detector : ULDA for supply and extract (same size as duct) CASE STUDY NURSERY, PLAY/RESTING ROOM MASS LIST: NURSERY/PLAYROOM Air management Optivent Ultra VAV-damper ULDA (2 pcs), length 900mm, BDER (2 pcs) Air diffusion Active supply diffuser (2 pcs) with CleanVent coating RAOH and ATTD Exhaust diffuser (2 pcs) with CleanVent coating HPKH C and ATTD Automation systems Room Controller (Modbus connection) STRA-04 Transformer STRZ-24-1 CO 2 -sensor STRZ External temperature sensor STRZ PIR Occupancy detector STRZ

15 PROPOSED DESIGN FUNCTIONS CO 2 -, temperature and occupancy sensors are observing room s indoor air climate Room controller receives messages from the different room sensors and controls the VAV function Room s ventilation system is constantly driven by demand controlled ventilation (from min. air flow to max. air flow) Active supply air diffuser OPTIMIX keeps precise throw length by using actuator BENEFITS Needs no safety distance in the tight duct installation in the corridor Dust resilienct and is splendid for rooms that contains lots of textile dust Reduced risk for draught close to the supply air device OPTIMIX (bunk bed) Silent ventilation system ( + OPTIMIX) provides good sleeping conditions Reduced need for maintenance work that create disturbances for the daily activities NURSERY, PLAY/RESTING ROOM area 25 m 2 Air volume +/- 100 l/s BDER Active supply diffuser with CleanVent coating Room Controller Modbus connection Tight hall Falce ceiling Occupancy detector on the wall VAV-damper CO 2 -sensor and External temperature sensor installed inside extract duct Exhaust diffuser with CleanVent coating 15

16 GUIDE TO PLANNING/ DIMENSIONING/CONFIGURATION School/ Class room Children have a tough working environment and high demands on their performance. Good air quality and low noise is crucial to stay focused and alert. Dust and varying presence place further technical demands on the ventilation system. As does tight operating budgets on optimised energy consumption and economy. PLANNING TIPS / CHECKLIST: CO 2 -sensor and Temperature sensor Min air flow in the room: 25 l/s (floor area 50 m²) Max air flow in the room: 150 l/s (loads = 1450 W and T=8 C) Supply air duct: ø 250mm (v=3,1 m/s with max air flow) Extract air duct: ø 250mm (0,4 Pa/m) : BDER for supply and extract (34 db(a) right after silencer with q=150 l/s and P=80Pa) Air pattern (Activent-020): max air velocity < 0,15 m/s in the occupational zone with minimum air flow and 0,2 m/s with maximum air flow Occupancy Detector Exhaust Grille Room Controller 3x Activent Supply Air VAV Damper VAV Damper : ULDA for supply and extract (same size as duct) CASE STUDY SCHOOL/CLASS ROOM MASS LIST: SCHOOL/CLASS ROOM Air management Optivent Ultra VAV-damper ULDA (2 pcs), length 900mm, BDER (2 pcs) Air diffusion Activent supply air distribution (3 pcs) systems ACTA Exhaust grille with CleanVent coating SV TGE B Automation systems Room Controller (Modbus connection) STRA-04 Transformer STRZ-24-1 CO 2 -sensor STRZ External temperature sensor STRZ PIR Occupancy detector STRZ

17 PROPOSED DESIGN FUNCTIONS CO 2 -, temperature and occupancy sensors are observing room s indoor air climate Room controller receives messages from the different room sensors and controls the VAV function Room s ventilation system is constantly driven by demand controlled ventilation BENEFITS Needs no safety distance in the tight duct installation in the corridor Dust resilient VAV damper is splendid for class rooms where are crowded people Wide air flow range is needed in class room Silent ventilation system to create optimal environment for learning Reduced need for maintenance work that create disturbances for the daily activities SCHOOL / CLASS ROOM area 50 m 2 Air volume +/- 150 l/s Exhaust grille with CleanVent coating Occupancy detector on the wall Activent supply air distribution system No lower roof False ceiling Tight hall Room Controller Modbus connection VAV-damper BDER CO 2 -sensor and External temperature sensor installed inside extract duct 17

18 GUIDE TO PLANNING/ DIMENSIONING/CONFIGURATION Office/ meeting room Office environments place high demands on the ventilation and air quality. Sedentary working conditions, with both tedious and stressful challenges, requires fresh air and good comfort to be able to perform. In meeting rooms, situations are even more demanding with loads varying between empty periods and crowded, intense long meetings. PLANNING TIPS / CHECKLIST: Min air flow in the room: 12,5 l/s (floor area 25 m²) Max air flow in the room: 100 l/s (loads=965 W and T=8 C ) Extract air duct: ø 200mm (0,65 Pa/m) : BDER for extract (33 db(a) right before silencer with q=100 l/s and P=80 Pa) 2x Chilled beam with PI-function and occupancy detector VAV Damper 3x Exhaust Valves CO 2 -sensor and Temperature sensor : ULDA for extract (same size as duct) Room Controller CASE STUDY OFFICE/MEETING ROOM MASS LIST: OFFICE/MEETING ROOM Air management Optivent Ultra VAV-damper ULDA , length 900mm, BDER Air diffusion Chilled beam WEGA II (2 pcs) IQII and IQAZ Water valve (2 pcs) heat. and cooling STRZ-70 Exhaust valve (3 pcs) with CleanVent coating KSO-125-C Automation systems Room Controller (Modbus connection) STRA-24 Transformer STRZ-24-1 CO 2 -sensor STRZ External temperature sensor STRZ Occupancy detector STRZ

19 PROPOSED DESIGN FUNCTIONS CO 2 -, temperature and occupancy sensors are observing room s indoor air climate Room controller receives messages from the different room sensors and controls the VAV damper (extract duct) and chilled beam s PI actuator movements Room s ventilation system is constantly driven by demand controlled ventilation BENEFITS Needs no safety distance in the tight duct installation in the corridor Wide air flow range is needed in meeting room Silent ventilation system guarantees good meeting conditions Reduced need for maintenance work that create disturbances for the daily activities OFFICE / MEETING ROOM area 25 m 2 Air volume +/- 100 l/s (10 persons) WEGA II chilled beam with PI-function Exhaust valves with CleanVent coating False ceiling Occupancy detector integr. in the beam CO 2 -sensor and External temperature sensor installed inside extract duct Room Controller Modbus connection Ø125 Heating and cooling pipes Tight hall BDER VAV-damper 19

20 GUIDE TO PLANNING/ DIMENSIONING/CONFIGURATION Business center/ Auditorium Big rooms with lots of volume pose specific challenges on the ventilation system. Large crowds, sometimes bringing outerwear, produce large amounts of dust. Capacity must also be dimensioned to deliver enough fresh air to ensure comfort with a crowded house. Still delicate moments in a concert or monologue can require almost complete silence to come through. PLANNING TIPS / CHECKLIST: Min air flow in the room: 150 l/s (floor area 300 m²) Max air flow in the room: 800 l/s (80 people) vs general rules Supply air duct: 2x ø 315 mm (v=5,13 m/s with max air flow) Extract air duct: 2x ø 315 mm (0,85 Pa/m) : ULDA for supply and extract (same size as duct) : BDER for supply and extract (53 db(a) right after silencer with q=100 l/s and P=80Pa) Air pattern (diffuser DASH-100): max air velocity 0,1 m/s in the occupational zone with maximum air flow Room Controller VAV Damper VAV Damper OPTIVENT ULTRA CO 2 sensor and Temperature sensor 40 x Supply Air Diffuser 15 x Exhaust Diffuser Occupancy Detector CASE STUDY BUSINESS CENTER/AUDITORIUM MASS LIST: BUSINESS CENTER/AUDITORIUM Air management Optivent Ultra VAV-damper ULDA (4 pcs), length 900mm, BDER (4 pcs) Air diffusion Supply diffuser (80 pcs) integrated behind steps DASH Exhaust diffuser (16 pcs) with CleanVent coating HPKH C and ATTD Automation systems Room Controller (Modbus connection) STRA-04 Transformer STRZ-24-1 CO 2 -sensor STRZ External temperature sensor STRZ PIR Occupancy detector STRZ

21 PROPOSED DESIGN FUNCTIONS CO 2 -, temperature and occupancy sensors are observing room s indoor air climate Room controller receives messages from the different room sensors and controls the VAV dampers Room s ventilation system is constantly driven by demand controlled ventilation BENEFITS Dust resilient construction is needed for auditorium that contains a lot of fabric dust from people s clothes Accurate air flow measuring and wide air flow range Silent ventilation is necessary during shows and recordings Reduced need for maintenance work that create disturbances for the daily activities Exhaust diffuser with CleanVent coating BUSINESS CENTER / AUDITORIUM area 300 m 2 Air volume +/- 800 l/s (100 persons) CO 2 -sensor and External temperature sensor installed inside extract duct Occupancy detector on the wall Room Controller Modbus connection Supply diffuser integrated behind steps BDER VAV-damper 21

22 GUIDE TO PLANNING/ DIMENSIONING/CONFIGURATION Hospital/ Patient room Medical facilities have high requirements. Also in patient wards demands are high. Weak and sick care recipients should be given good recovery conditions and need no extra strain from bad air quality or comfort. A special demand is put on the ventilation system to be maintenance free, when premises are occupied 24/7. PLANNING TIPS / CHECKLIST: Min air flow in the room: 12,5 l/s (floor area 25 m²) Max air flow in the room: 38 l/s (loads = 370 W and T=8 C) Supply air duct: ø 125mm (v=3,1 m/s with max air flow) Extract air duct: ø 125mm (0,4 Pa/m) : ULDA for supply and extract (same size as duct) : BDER for supply and extract (36 db(a) right after silencer with q=38 l/s and P=80 Pa) Air pattern (diffuser DYVB-125): max air velocity < 0,15 m/s in the occupational zone with minimum air flow and 0,16 m/s with maximum air flow CO 2 -sensor Temperature sensor VAV Damper OPTIVENT ULTRA Exhaust Grille CASE STUDY HOSPITAL / PATIENT ROOM VAV Damper OPTIVENT ULTRA Room Controller Supply nozzle diffuser Occupancy Detector MASS LIST: HOSPITAL / PATIENT ROOM Air management Optivent Ultra VAV-damper ULDA (2 pcs), length 600mm, BDER (2 pcs) Air diffusion Wall nozzle diffuser (2 pcs) with CleanVent coating DYVZ-125 and ATVA Exhaust grille with CleanVent coating SV and TGE B Automation systems Room Controller (Modbus connection) STRA-04 Transformer STRZ-24-1 CO 2 -sensor STRZ External temperature sensor STRZ PIR Occupancy detector STRZ

23 PROPOSED DESIGN FUNCTIONS CO 2 -, temperature and occupancy sensors are observing room s indoor air climate Room controller receives messages from the different room sensors and controls the VAV dampers Room s ventilation system is constantly driven by demand controlled ventilation BENEFITS Needs no safety distance in the tight duct installation in the corridor Dust resilient construction is needed for the patient room because of fabric dust. Silent ventilation guarantees good recovery conditions for the patient Reduced need for maintenance work that create disturbances for the daily activities HOSPITAL / PATIENT ROOM area 25 m 2 Air volume +/- 38 l/s BDER VAV-damper Occupancy detector on the wall Tight hall No lower roof Wall nozzle diffuser with CleanVent coating Room Controller Modbus connection CO 2 -sensor and External temperature sensor installed inside extract duct Exhaust grille with CleanVent coating 23

24 GUIDE TO PLANNING/ DIMENSIONING/CONFIGURATION Residential/ Apartment In our homes we sometimes don t enjoy carefully constructed ventilation systems and good air quality. Still this is the place we spend more time than anywhere else. The domestic activities are varying in their demands. Moist in the bathroom, heat and smells in the kitchen, dust from textiles in the laundry room, not to speak of the silence required in the bedroom to sleep well. PLANNING TIPS / CHECKLIST: Min air flow in the room: 7 l/s (apartment: -60% vs designed air flow, 18 l/s) Max air flow in the room: 23 l/s (apartment: +30% vs designed air flow 18 l/s) Supply air duct: ø 100 mm 2,9 m/s with max air flow) Extract air duct: ø 100 mm (1,1 Pa/m with max air flow) : ULSA for supply and extract (same size as duct) : BDER for supply and extract (37 db(a) right after silencer with q=23 l/s andδp=80 Pa Air pattern (diffuser STQA-100-C): max air velocity 0,12 m/s in the occupational zone with minimum air flow and < 0,15 m/s with maximum air flow. VAV damper OPTIVENT ULTRA Manual Room Controller Connection Box CASE STUDY RESIDENTIAL / APARTMENT Exhaust Valve Supply Valve Supply Valve Kitchen Hood MASS LIST: RESIDENTIAL / APARTMENT Air management Optivent Ultra VAV-damper ULSA (2 pcs), length 600mm, BDER (2 pcs) Mounting clamps (4 pcs) HVSZ Air diffusion Exhaust valve with Clean- Vent coating KSO-100-C Supply valve (2 pcs) with CleanVent coating STQA-100-C Kitchen Hood (ILOXAIR) with stove guard ROSALA Automation systems Connection box with transformer and cooker hood control equipment HVLZ-02 Manual room controller HVSZ-01 24

25 PROPOSED DESIGN FUNCTIONS Manual room controller with 3 positions (non-occupancy, normal air flow and max air flow) Room controller is also connected to the kitchen hood (equipped with microswitch) When kitchen hood operates at maximum, increases supply air and also decreases extract air to retain balance is pressure independent for duct pressure fluctuations BENEFITS Needs no safety distance in the tight duct installation in the corridor Extremely accurate air flow measurement guarantees the right pressure balance in the apartment A silent ventilation system guarantees good sleeping conditions in the bedroom Reduced need for maintenance work that create disturbances for the daily activities Dust resilient construction is splendid for laundry room/ bath room, that contains lots of fabric dust RESIDENTIAL / APARTMENT area 25 m 2 Air volume +/-18 l/s Staircase Manual room controller False ceiling VAV-damper False ceiling No lower roof Exhaust valves with CleanVent coating BDER Supply valve with CleanVent coating Kitchen Hood (ILOXAIR) with stove guard 25

26 DESIGNED FOR UNIQUE PRECISION EQUIPPED FOR SIMPLE INTEGRATION is easily integrable in any ventilation solution. It follows accepted standards for control and has a full-fledged communications interface. 1 Value selector 2 Function selector The controller can be operated via Modbus or with analogue signal, which is set to a standard value of 0 10V on delivery. The address can be selected from the range With the function selector in the adr position, select the desired address using the value selector. Hardware settings (baudrate, parity and stop bits) can be changed by setting the function selector to adr and then turning the value selector until the parameter 2in is displayed. This opens up a submenu, which is indicated by a small circle on the display. Modbus load ¼ Modbus registers are available in the technical documentation. 3 Display

27 Technical data Sizes 100, 125, 160, 200, 250 and 315 mm For easy configuration, select Fläkt Select! Material Galvanized steel Air velocity 0,5 15 m/s Running time 100 s / 90 Power supply 24 V AC/DC Ambient temperature +5 C C Storage temperature - 20 C C Transport temperature - 40 C C SELECT is a new web-based selection tool which focuses on indoor air comfort products, providing customers with great flexibility when configuring solutions via its user friendly interface. Currently this tool is available for indoor air climate products in the categories Air Diffusion, Air Distribution and Air Management. Ambient humidity Service Life Maintenance 5 95 % r.h. non condensing (EN ) > cycles ( ) > partial cycles (max. +/-5 ) Maintenance-free TWO EXAMPLES Ordering codes ULaA-b-ccc-d Flow variator, round Execution (a) S = without insulation, D = with insulation Sound calculation Actuator (b) 5 = compact controller for Modbus 227VMZ-MB 6 = compact controller for Modbus, IPSUM version 227VMZ-MB Size (ccc) 100, 125, 160, 200, 250, 315 Material (d) 1 = Corrosivity class C3, galvanized sheet steel Air pattern 27

28 FG_DC-10063GB_Optivent Ultra_AP_ _R0 Copyright 2018 FläktGroup FläktGroup is the European market leader for smart and energy efficient Indoor Air and Critical Air solutions to support every application area. We offer our customers innovative technologies, high quality and outstanding performance supported by more than a century of accumulated industry experience. The widest product range in the market, and strong market presence in 65 countries worldwide, guarantee that we are always by your side, ready to deliver Excellence in Solutions. PRODUCT FUNCTIONS BY FLÄKTGROUP Air Treatment Air Movement Air Diffusion Air Distribution Air Filtration Air Management & ATD s Air Conditioning & Heating Controls Service» Learn more on or contact one of our offices

VAV CHILLED BEAMS Pi FUNCTION DESIGN GUIDE

VAV CHILLED BEAMS Pi FUNCTION DESIGN GUIDE VAV CHILLED BEAMS Pi FUNCTION DESIGN GUIDE 2 VAV Chilled beams with function - Design Guide CONTENT Dimensioning of VAV Chilled beam Function...3 Operation levels... 4 Heating...5 Dimensioning of chilled

More information

AIR DIFFUSION A COMPLETE RANGE OF CHILLED BEAMS FOR COMFORT AND FLEXIBILITY CHILLED BEAMS. iq Star Lyra II iq Star Stella Flexicool IQID

AIR DIFFUSION A COMPLETE RANGE OF CHILLED BEAMS FOR COMFORT AND FLEXIBILITY CHILLED BEAMS. iq Star Lyra II iq Star Stella Flexicool IQID AIR DIFFUSION CHILLED BEAMS A COMPLETE RANGE OF CHILLED BEAMS FOR COMFORT AND FLEXIBILITY iq Star Wega II iq Star Nova II iq Star Lyra II iq Star Stella Flexicool IQID 2 CHILLED BEAMS by FLÄKTGROUP TOP

More information

A COMPLETE RANGE OF CHILLED BEAMS FOR COMFORT AND FLEXIBILITY

A COMPLETE RANGE OF CHILLED BEAMS FOR COMFORT AND FLEXIBILITY AIR COMFORT AIR DIFFUSION CHILLED AIR HANDLING BEAMSUNITS A COMPLETE RANGE OF CHILLED BEAMS FOR COMFORT AND FLEXIBILITY iq Star Wega II iq Star Nova II iq Star Lyra II iq Star Stella Flexicool IQID 2 CHILLED

More information

LYRA » ENERGY EFFICIENT CASSETTE CHILLED BEAM AIR DIFFUSION LYRA

LYRA » ENERGY EFFICIENT CASSETTE CHILLED BEAM AIR DIFFUSION LYRA AIR DIFFUSION LYRA LYRA» ENERGY EFFICIENT CASSETTE CHILLED BEAM Energy efficiency the essence of our solutions All our research, development and testing activities are singularly focused to provide our

More information

IPSUM OPTIMIZATION SYSTEM» DEMAND CONTROLLED VENTILATION OVERVIEW

IPSUM OPTIMIZATION SYSTEM» DEMAND CONTROLLED VENTILATION OVERVIEW AIR COMFORT AIR MANAGEMENT IPSUM IPSUM OPTIMIZATION SYSTEM» DEMAND CONTROLLED VENTILATION OVERVIEW IPSUM SYSTEM OPTIMIZER IPSUM SYSTEM ROUTER IPSUM CONNECTION UNIT IPSUM from Fläkt Woods a giant step forward!

More information

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT AIR TREATMENT ReCOOLER HP ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT Energy efficiency the essence of our solutions All our research, development

More information

iq Star LYRA II chilled beam cassette

iq Star LYRA II chilled beam cassette iq Star LYRA II chilled beam cassette Key features Ventilation Heating and cooling Compact chilled beam Adjustable induction Flow Pattern Control Integrated control In option: Demand Controlled Ventilation,

More information

VERSO Air Handling Units

VERSO Air Handling Units Energy efficient solutions for profitable indoor climate VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P air handling units equipped with recuperation system

More information

Demand-controlled Ventilation Leading edge products for demand-controlled ventilation

Demand-controlled Ventilation Leading edge products for demand-controlled ventilation Overview Demand-controlled Ventilation Leading edge products for demand-controlled ventilation Demand-controlled ventilation offers great comfort and low operating costs When the room is in use, ventilation

More information

CHILLED BEAM CASSETTE IQ STAR LYRA

CHILLED BEAM CASSETTE IQ STAR LYRA CHILLED BEAM CASSETTE IQ STAR LYRA TECHNICAL CATALOGUE 2 IQ Star LYRA Chilled beam cassette - Technical catalogue IQ STAR LYRA CHILLED BEAM CASSETTE The LYRA chilled beam cassette is a compact chilled

More information

HOTEL CHILLED BEAM IQ STAR SILENCIA

HOTEL CHILLED BEAM IQ STAR SILENCIA HOTEL CHILLED BEAM IQ STAR SILENCIA TECHNICAL CATALOGUE 2 IQ Star Silencia Hotel Chilled beam - Technical catalogue IQ STAR SILENCIA HOTEL CHILLED BEAM Silencia unit is designed for use in hotel bedrooms,

More information

VERSO Air Handling Units

VERSO Air Handling Units VERSO Air Handling Units Energy efficient solutions for profitable indoor climate VERSO Air Handling Units VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P

More information

DAIKIN Air Handling Unit Modular

DAIKIN Air Handling Unit Modular DAIKIN Air Handling Unit Modular Compact ventilation unit with heat recovery Energy efficiency and air quality Daikin air handling units, with their plug-and-play design and inherent flexibility, can be

More information

eq PRIME » ENERGY EFFICIENCY AND FLEXIBILITY STRAIGHT OUT OF THE BOX AIR COMFORT AIR TREATMENT AIR HANDLING UNITS

eq PRIME » ENERGY EFFICIENCY AND FLEXIBILITY STRAIGHT OUT OF THE BOX AIR COMFORT AIR TREATMENT AIR HANDLING UNITS AIR COMFORT AIR TREATMENT AIR HANDLING UNITS eq PRIME» ENERGY EFFICIENCY AND FLEXIBILITY STRAIGHT OUT OF THE BOX ENVIRONMENT ECONOMICAL EXPERTISE In its simplicity the e 3 captures what makes us attractive

More information

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25 Residential Heat Recovery Ventilation REHVA European Guidebook No 25 REHVA European Guidebook No 25 2 Limited to mechanical supply and exhaust ventilation Targeted to engineers, HVAC consultants and contractors

More information

Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system

Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system Viewpoint August 2012 Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system Dr Sarah Price and Helen Brown Summary Mechanical Ventilation and Heat

More information

DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION

DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION 2 AERECO DX system DX SYSTEM A COMPLETELY NEW HEAT RECOVERY VENTILATION RANGE With the experience of a very innovative room-by-room demand

More information

Daikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel

Daikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel Daikin Applied UK Technically better... D-AHU Modular R Air handling units Compact air handling unit with heat recovery wheel Energy efficiency and air quality With their Plug & Play design and inherent

More information

Breathe Fresh Air at Home

Breathe Fresh Air at Home Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans Breathe Fresh Air at Home Residential Ventilation 2 Category name / Registername

More information

iq Star LYRA II chilled beam cassette

iq Star LYRA II chilled beam cassette Key features The LYRA II cassette is an active chilled beam for ventilation, cooling and heating. This diffusion system offers high flexibility thanks to the combination of Flow Pattern Control, Coanda

More information

SEMCO CHILLED BEAMS INDOOR AIR QUALITY AND ENERGY SAVINGS FANLESS FILTERLESS SPACE CONDITIONING

SEMCO CHILLED BEAMS INDOOR AIR QUALITY AND ENERGY SAVINGS FANLESS FILTERLESS SPACE CONDITIONING FANLESS FILTERLESS SPACE CONDITIONING SEMCO CHILLED BEAMS INDOOR AIR QUALITY AND ENERGY SAVINGS IQHC Active Chilled Beam An intelligently designed active chilled beam that has the highest industry cooling

More information

Endura Delta. Demand- and app-controlled ventilation system with heat recovery

Endura Delta. Demand- and app-controlled ventilation system with heat recovery Endura Delta Demand- and app-controlled ventilation system with heat recovery Introduction < Endura Delta As an occupant we are increasingly aware of the fact that energy-efficient construction should

More information

Typologies of Hybrid Ventilation in Schools

Typologies of Hybrid Ventilation in Schools Typologies of Hybrid Ventilation in Schools Peter van den Engel Delft Technological University, the Netherlands Corresponding email: p.vd.engel@deerns.nl SUMMARY This article is the result of a study on

More information

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction Air Comfort Air Treatment Energy Recovery eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction eco PREMIUM - Technical Instruction REDA 2 Contents Description Applications... 3 Quality & environment...

More information

CITY OF DANA POINT. COMMUNITY DEVELOPMENT, BUILDING AND SAFETY Golden Lantern, Suite 209 Dana Point, CA

CITY OF DANA POINT. COMMUNITY DEVELOPMENT, BUILDING AND SAFETY Golden Lantern, Suite 209 Dana Point, CA CITY OF DANA POINT COMMUNITY DEVELOPMENT, BUILDING AND SAFETY 33282 Golden Lantern, Suite 209 Dana Point, CA 92629 949 248 3594 www.danapoint.org INDOOR AIR QUALITY B011 AIR 2013 CALIFORNIA CODES CODE

More information

MARINE APPLICATIONS MARINE» PRODUCTS AND SOLUTIONS FOR MARINE APPLICATIONS

MARINE APPLICATIONS MARINE» PRODUCTS AND SOLUTIONS FOR MARINE APPLICATIONS MARINE APPLICATIONS MARINE» PRODUCTS AND SOLUTIONS FOR MARINE APPLICATIONS MEETING THE HIGHEST DEMANDS - EFFICIENT HVAC SOLUTIONS FOR ARCTICAL TO TROPICAL CONDITIONS AT FLÄKTGROUP WE WANT TO EXCEED the

More information

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams Integrated chilled beams Key figures Connections: 1x mm, 2x mm Airflow: 5-60 l/s Pressure range: 40 - Pa Size: 293 x 200 mm (WxH) Length: 1192 or 1792 mm Total effect: up to 1200W Cumulus is available

More information

Contents. Technical Description of the Air Handling Unit General, Specification Function, Functional Sections

Contents. Technical Description of the Air Handling Unit General, Specification Function, Functional Sections Room unit Contents Technical Description of the Air Handling Unit General, Specification... 146 Function, Functional Sections... 147 Control System Control Display, Airflow Control... 148 Temperature Control...

More information

The power of ventilation

The power of ventilation The power of ventilation LindabAir Handling Unit Ensure the correct flow of fresh air, acceleration at the right rate and exact volume lindab.com 1 lindab air handling units Air Handling Units that maximise

More information

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units Premium Efficiency Heat Recovery Unit D-AHU Modular L Air Handling Units About Daikin Our promise is to ensure that customers can depend on Daikin for the ultimate in comfort, so that they are free to

More information

lindab ventilation Lindab Comfort Waterborne indoor climate solutions Product overview

lindab ventilation Lindab Comfort Waterborne indoor climate solutions Product overview lindab ventilation Lindab Comfort Product overview Products within the Lindab Waterborne solutions, e.g. chilled beams, facade systems, radiant heating and cooling panels, uses water to regulate the room

More information

Systemair product news - Fans NEWS

Systemair product news - Fans NEWS Systemair product news - Fans NEWS Perfect Climate. Anywhere. Anytime Smart, energy-saving solutions for ventilation and air-conditioning. Well-thought-out system solutions for every application area.

More information

MODBUS RS485 TECHNICAL INSTRUCTIONS

MODBUS RS485 TECHNICAL INSTRUCTIONS MODBUS RS485 TECHNICAL INSTRUCTIONS 2 Modbus RS485 - Technical instruction DESCRIPTION, CONNECTIONS, PRESENTATION, DECIMALS DESCRIPTION RS485 has two connections, A and B. Often there is also a protective

More information

AERECO DEMAND CONTROLLED VENTILATION COMBINING INDOOR AIR QUALITY AND ENERGY SAVINGS

AERECO DEMAND CONTROLLED VENTILATION COMBINING INDOOR AIR QUALITY AND ENERGY SAVINGS AERECO DEMAND CONTROLLED VENTILATION COMBINING INDOOR AIR QUALITY AND ENERGY SAVINGS INNOVATION THAT EXCELS IN AIR QUALITY AND ENERGY SAVINGS Aereco demand controlled ventilation Combining indoor air quality

More information

lindab we simplify construction LindabIndoorClimateSolutions Product overview Airborne Solutions

lindab we simplify construction LindabIndoorClimateSolutions Product overview Airborne Solutions lindab we simplify construction LindabIndoorClimateSolutions Product overview Airborne Solutions 2 We simplify construction At Lindab we are driven by a strong desire to continuously generate improvements

More information

Healthy, comfortable and energy-efficient ventilation

Healthy, comfortable and energy-efficient ventilation Healthy, comfortable and energy-efficient ventilation partner Renovent Excellent 180, 300 and 400 Silent and energy-efficient ventilation 300/400 180 Central ventilation The Renovent Excellent is a mechanical

More information

Do More With Less

Do More With Less 1300 306 125 www.livezi.com.au Do More With Less Livezi have been the leaders in residential multizone full temperature systems since the mid nineteen nineties. Our 2012 product line-up represents the

More information

Halton Vario Design Guide

Halton Vario Design Guide Halton Vario Design Guide Enabling Wellbeing Table of contents 1. Halton Vario - ventilation and air conditioning system overview 3 1.1 Room level, Zonal level and central level 4 1.2 Flexible design and

More information

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range & 300 Exceptionally low energy consumption High Efficiency, Low Profile Heat Recovery Range & 300 High Efficiency, Low Profile Heat Recovery Range High-efficiency, low profile MVHR units to deliver exceptionally

More information

VRV The total solution. Integrated Climate Control

VRV The total solution. Integrated Climate Control VRV The total solution Integrated Climate Control Total Solution Concept The Daikin VRV Total Solution provides a single point of contact for the design and maintenance of your integrated climate control

More information

iq Star by Fläkt Woods Multi-service Chilled Beam Guide Star by Fläkt Woods

iq Star by Fläkt Woods Multi-service Chilled Beam Guide Star by Fläkt Woods Star by Fläkt Woods iq Star by Fläkt Woods Multi-service Chilled Beam Guide The right cooling at the right time. Purposeful and energy efficient. The modern office is dynamic. With laptops and mobiles

More information

Technical Selection. elevent ceiling diffusers. Swirl, Jet, Louvred and Curved ceiling diffusers

Technical Selection. elevent ceiling diffusers. Swirl, Jet, Louvred and Curved ceiling diffusers elevent ceiling diffusers Technical Selection Swirl, Jet, Louvred and Curved ceiling diffusers Paltech elevent Ceiling Diffusers are protected by: Australian Patent 0179430 + other patents pending Australian

More information

MODBUS RS485. » Technical instructions. Air Comfort. Housing ventilation

MODBUS RS485. » Technical instructions. Air Comfort. Housing ventilation Air Comfort Air Treatment Housing ventilation MODBUS RS485» Technical instructions 2 Modbus RS485 Technical instructions Description, Connections, Presentation, decimals Description RS485 has two connections,

More information

SIMPLICITY FULL MODULARITY?

SIMPLICITY FULL MODULARITY? D E S I G N I N G I N N O V A T I V E S O L U T I O N S AIR CONDITIONING & HEATING SOLUTIONS OR SIMPLICITY FULL MODULARITY? IDROFAN, BECAUSE YOU SHOULD NOT HAVE TO CHOOSE. Hydronic ducted fan coils Cooling

More information

WORLD VENTILATION LEADER SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS

WORLD VENTILATION LEADER   SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS WORLD VENTILATION LEADER IO EM.COM SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS VENTS reserves the rights to modify any of its products featuers, designs, components and specifications

More information

CLIMATE SEPARATION SOLUTION. SensAir

CLIMATE SEPARATION SOLUTION. SensAir CLIMATE SEPARATION SOLUTION SensAir SensAir comfort air curtain A new wave in climate separation SensAir air curtains are the ideal solution for retailers and other end-users to combat the issue of climate

More information

DISCHARGING. electrostatic innovations. Top-Class Discharging

DISCHARGING. electrostatic innovations. Top-Class Discharging DISCHARGING Top-Class Discharging DISCHARGING BASIX The optimum choice for many applications The new discharging system Eltex BASIX 100% Eltex at a low price The Eltex discharging technology is suitable

More information

Improved Thermal Comfort & Energy Efficiency with low-pressure VAV diffusion design

Improved Thermal Comfort & Energy Efficiency with low-pressure VAV diffusion design Improved Thermal Comfort & Energy Efficiency with low-pressure VAV diffusion design Technical Paper A guide to the design of an effective low pressure VAV air distribution system By Noel de Villiers Pr.

More information

CHAPTER 4. HVAC DELIVERY SYSTEMS

CHAPTER 4. HVAC DELIVERY SYSTEMS CHAPTER 4. HVAC DELIVERY SYSTEMS 4.1 Introduction 4.2 Centralized System versus Individual System 4.3 Heat Transfer Fluids 4.4 CAV versus VAV Systems 4.5 Common Systems for Heating and Cooling 4.6 Economizer

More information

Helios in a new dimension.

Helios in a new dimension. Helios in a new dimension. Helios AIR1 the new dimension of more energy-efficient compact ventilation units. Even larger. Even more. Even simpler. 02 Helios As a pioneer in energy-efficient ventilation

More information

SIMPLICITY OR FULL MODULARITY?

SIMPLICITY OR FULL MODULARITY? D E S I G N I N G I N N O V A T I V E S O L U T I O N S AIR CONDITIONING & HEATING SOLUTIONS SIMPLICITY OR FULL MODULARITY? IDROFAN, BECAUSE YOU SHOULD NOT HAVE TO CHOOSE. Hydronic ducted fan coils Cooling

More information

DESIGN OF AIR-CONDITIONING SYSTEM FOR SARS WARDS. By Yuguo Li and SARS Busters * Background

DESIGN OF AIR-CONDITIONING SYSTEM FOR SARS WARDS. By Yuguo Li and SARS Busters * Background DESIGN OF AIR-CONDITIONING SYSTEM FOR SARS WARDS By Yuguo Li and SARS Busters * Background The hospital care workers (HCWs) have been the most severely affected professions during the SARS epidemics in

More information

Mobile climate solutions

Mobile climate solutions Mobile climate solutions 108 121 Under-bench air conditioners 122 12 102 10 102 Air conditioners Climate as desired Take your pick: the Dometic range offers air conditioners in all performance categories

More information

HAP e-help. Modeling Induction Beams in HAP v4.8 QB TIP 001

HAP e-help. Modeling Induction Beams in HAP v4.8 QB TIP 001 This HAP e-help provides a high-level overview of induction beams, how they work and how to model them in HAP 4.8 (and later versions). The first half of the article explains how induction beams work.

More information

Think System Solution to get it right first time

Think System Solution to get it right first time NOISE Think System Solution to get it right first time Overcoming issues when Heat Recovery Ventilation goes wrong is costly and time consuming. Like many whole house systems, the individual components

More information

RADIATOR THERMOSTAT THE MOST INTELLIGENT THERMOSTAT. EVER.* *Available for purchase in October!

RADIATOR THERMOSTAT THE MOST INTELLIGENT THERMOSTAT. EVER.* *Available for purchase in October! RADIATOR THERMOSTAT THE MOST INTELLIGENT THERMOSTAT. EVER.* *Available for purchase in October! SPECTACULAR ARRAY OF POSSIBILITIES FIBARO decentralizes the heating process! Instead of a single controlling

More information

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply. Halton CSW Swirl comfort unit for ceiling installation The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply. A combined cooling, heating, and supply-air unit for flush

More information

The Silent Range Pure Elegance & Tranquillity. The widest range of ultra quiet silent fans

The Silent Range Pure Elegance & Tranquillity. The widest range of ultra quiet silent fans The Silent Range Pure Elegance & Tranquillity The widest range of ultra quiet silent fans The most advanced SILENT technology delivering the highest extract performance. 1 Your first choice for ventilation

More information

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION Swegon CASA W130 Ventilation unit with counter-flow plate heat exchanger Ventilation unit for residential houses under 250 m². The unit has counter-flow plate heat exchanger. Suitable also for renovation

More information

Infinity 18VS. Heat Pump with Variable-Speed Technology. Variable-Speed, High-Efficiency Heat Pump with up to 18.0 SEER and up to 11.

Infinity 18VS. Heat Pump with Variable-Speed Technology. Variable-Speed, High-Efficiency Heat Pump with up to 18.0 SEER and up to 11. Infinity 18VS Heat Pump with Variable-Speed Technology Variable-Speed, High-Efficiency Heat Pump with up to 18.0 SEER and up to 11.0 HSPF What Efficiency Means to You Extra High-Efficiency Heat Pump Designed

More information

Chilled beam technology overview John Woollett 1, Jonas Åkesson 2 Swegon AB 1,2

Chilled beam technology overview John Woollett 1, Jonas Åkesson 2 Swegon AB 1,2 Chilled beam technology overview John Woollett 1, Jonas Åkesson 2 Swegon AB 1,2 john.woollett@swegon.se, jonas.akesson@swegon.se SUMMARY The main focus of the paper will be on active beam technology regarding

More information

VMX DEMAND CONTROLLED VENTILATION FOR NON RESIDENTIAL BUILDINGS

VMX DEMAND CONTROLLED VENTILATION FOR NON RESIDENTIAL BUILDINGS VMX DEMAND CONTROLLED VENTILATION FOR NON RESIDENTIAL BUILDINGS 2 AERECO VMX VMX, A UNIQUE SOLUTION TO RECONCILE AIR QUALITY AND ENERGY SAVINGS IN NON RESIDENTIAL BUILDINGS AERECO VMX 3 In developed countries,

More information

PFS Single stage axial fan The axial fan for modern boiler plants

PFS Single stage axial fan The axial fan for modern boiler plants PFS Single stage axial fan The axial fan for modern boiler plants This large axial fan, type PFS- 400-236, was installed in 1987 at the Salmisaari coal-fired power station in Helsinki, Finland. The photo

More information

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h VENTILATION equipment VENTILATION equipment content DOMEKT Residential ventilation units 50 1 000 m³/h 15 VERSO Non residential ventilation units 1000 34 000 m³/h 61 Domekt R 17 Domekt R 200 V 19 Domekt

More information

KLIMA Active Chilled Beams

KLIMA Active Chilled Beams KLIMA 2 600 Active Chilled Beams Index Subject Page Index 1 Introduction 2 General description 3-4 Product features 5-6 Dimensions 7 Performance data 8-11 Section example Guide specifications 13 1 Introduction

More information

Waterborne Climate Systems

Waterborne Climate Systems Overview Waterborne Climate Systems Optimal indoor climate with demand-controlled and energy efficient products Flexible, low energy-use + low maintenance with Swegon s climate systems! There are many

More information

CI/SfB (57.7) 1st Edition. Lo-Carbon Response/SELV dmev Unit. A new generation of Lo-Carbon continuous running fans

CI/SfB (57.7) 1st Edition. Lo-Carbon Response/SELV dmev Unit. A new generation of Lo-Carbon continuous running fans CI/SfB (57.7) 1st Edition A new generation of Lo-Carbon continuous running fans Lo-Carbon Response/SELV dmev Unit A new generation of Lo-Carbon continuous running fans Looking towards the future Vent-Axia

More information

AIR HEATING UNIT HEATMASTER ACJB INSTALLATION, OPERATION, MAINTENANCE AND SPARE PARTS

AIR HEATING UNIT HEATMASTER ACJB INSTALLATION, OPERATION, MAINTENANCE AND SPARE PARTS AIR HEATING UNIT HEATMASTER ACJB INSTALLATION, OPERATION, MAINTENANCE AND SPARE PARTS 2 Air Heating unit ACJB - Technical manual CONTENTS OPERATION AND MAINTENANCE (FOR USER) System, functions, main components...3

More information

Whole Home Heat Recovery Ventilation

Whole Home Heat Recovery Ventilation Whole Home Heat Recovery Ventilation Lossnay VL220. Clean Fresh Air; for a Healthier, Drier and Warmer Home. Balanced Pressure Home Ventilation. Made in Japan, Designed for New Zealand Conditions. Lossnay

More information

Underfloor Air Systems. How It s Different: Overhead vs. Underfloor Air Systems

Underfloor Air Systems. How It s Different: Overhead vs. Underfloor Air Systems Underfloor Air Fresher Design Developers, building owners and architects face a complex challenge: build buildings that are not only pleasing aesthetically, but also are efficient, flexible and smart.

More information

Halton Rex for Vario R6O - Variable air volume chilled beam

Halton Rex for Vario R6O - Variable air volume chilled beam Halton Rex for Vario R6O - Variable air volume chilled beam Halton Rex for Vario chilled beam is: Combined cooling, heating, and supply air unit for flush installation within a suspended ceiling Well suited

More information

energisava 300 & 400 Constant flow technology High Efficiency Whole House Heat Recovery Systems

energisava 300 & 400 Constant flow technology High Efficiency Whole House Heat Recovery Systems energisava 300 & 400 Constant flow technology High Efficiency Whole House Heat Recovery Systems energisava 300 & 400 High Efficiency Whole House Heat Recovery Systems Providing all year round good indoor

More information

Infinity 19VS. Air Conditioner with Variable-Speed Technology. Variable-Speed, High-Efficiency Air Conditioner with up to 19.

Infinity 19VS. Air Conditioner with Variable-Speed Technology. Variable-Speed, High-Efficiency Air Conditioner with up to 19. Infinity 19VS Air Conditioner with Variable-Speed Technology Variable-Speed, High-Efficiency Air Conditioner with up to 19.0 SEER Innovation and the Environment Leaders in Technology Over 100 years ago,

More information

Vireo Fresh intelligence

Vireo Fresh intelligence Vireo Fresh intelligence www.fresh-intelligence.co.uk Heat Recovery Ventilation Vireo Fresh intelligence Vireo: An elegant white good designed for all types of new homes. Heat Recovery Ventilation with

More information

recooler HP EQKR HEAT PUMP

recooler HP EQKR HEAT PUMP AIR COMFORT AIR TREATMENT 9566 GB 2016.03.17 recooler HP EQKR HEAT PUMP» TECHNICAL CATALOGUE 2 ReCooler HP EQKR Technical Catalogue Content ReCOOLER HP EQKR HEAT PUMP 3 product presentation. 3 applications.

More information

Healthy, comfortable and energy-efficient ventilation

Healthy, comfortable and energy-efficient ventilation Healthy, comfortable and energy-efficient ventilation 300/400/450 180 Renovent Excellent 180, 300, 400 and 450 Silent and energy-efficient ventilation Central ventilation The Renovent Excellent is a mechanical

More information

DIGITAL HOT WATER SOLUTIONS

DIGITAL HOT WATER SOLUTIONS DIGITAL HOT WATER SOLUTIONS ARMSTRONG IS A TRUSTED GLOBAL LEADER IN INSTANTANEOUS HOT WATER GENERATION, DISTRIBUTION AND PRECISION TEMPERATURE CONTROL With in-depth knowledge and experience that spans

More information

CLIMATE SEPARATION SOLUTION. SensAir

CLIMATE SEPARATION SOLUTION. SensAir CLIMATE SEPARATION SOLUTION SensAir SensAir comfort air curtain A new wave in climate separation SensAir air curtains are the ideal solution for retailers and other end-users to combat the issue of climate

More information

» WITH REGASORP ROTARY HEAT EXCHANGER

» WITH REGASORP ROTARY HEAT EXCHANGER AIR TREATMENT eq AIR HANDLING UNITS REGASORP» WITH REGASORP ROTARY HEAT EXCHANGER eq WITH REGASORP ROTARY HEAT EXCHANGER REDUCES COST UP TO 50% Two of the most important factors affecting indoor air climate

More information

PARAGONTM Comfort module for hotel rooms and hospital wards

PARAGONTM Comfort module for hotel rooms and hospital wards PARAGONTM Comfort module for hotel rooms and hospital wards Now with improved cooling and heating capacity www.swegon.com PARAGON A PARAGON for each requirement Normal capacity NC, cooling heating, Thermal

More information

Heat Recovery Air Handling Units

Heat Recovery Air Handling Units Heat Recovery ir Handling Units OMEKT Heat recovery air handling Units OMEKT 1 KOMFOVENT OMEKT ir Handling Units Komfovent ir Handling units are made to create healthy indoor climate and ensure efficient

More information

Cerberus PRO intelligent fire protection. A comprehensive portfolio of innovative and industry-leading technology.

Cerberus PRO intelligent fire protection. A comprehensive portfolio of innovative and industry-leading technology. Cerberus PRO intelligent fire protection A comprehensive portfolio of innovative and industry-leading technology www.usa.siemens.com/cerberus-pro Cerberus PRO the comprehensive fire protection system Intelligent

More information

Primo Hotel. General. Indoor climate units for hotel rooms

Primo Hotel. General. Indoor climate units for hotel rooms Indoor climate units for hotel rooms General Primo Hotel indoor climate unit Ceiling-mounted indoor climate units for ventilation, cooling and heating High capacity; occupies little space Dry system without

More information

Always the best climate for the IDEAL INSTALLATION

Always the best climate for the IDEAL INSTALLATION Decorative radiators Comfortable indoor ventilation Heating and cooling ceiling systems Clean air solutions Always the best climate for the IDEAL INSTALLATION New generation ventilation units Zehnder ComfoAir

More information

Heat recovery unit RDKS

Heat recovery unit RDKS Heat recovery unit RDKS Heat recovery unit RDAS is based on our RDAR unit and develops this further. The unit has a rotary heat exchanger with stepless speed control. This allows for very precise temperature

More information

Mobile climate solutions

Mobile climate solutions Mobile climate solutions Roof air conditioners 102 111 Under-bench air conditioner 112 11 www.dometic-waeco.com 9 95 9 Mobile climate solutions Climate as desired Take your pick: the Dometic range offers

More information

UniTrane U-Line ductable water terminals Optimum efficiency with a sound reduction bonus

UniTrane U-Line ductable water terminals Optimum efficiency with a sound reduction bonus UniTrane U-Line ductable water terminals Optimum efficiency with a sound reduction bonus The perfect fit where quality and comfort Adding to Trane s broad portfolio of water terminals, the new Trane UniTrane

More information

Smoke Control Ducts and Dampers For Single Compartment Applications. Fulfilling new requirements for EN product standards for CE Marking

Smoke Control Ducts and Dampers For Single Compartment Applications. Fulfilling new requirements for EN product standards for CE Marking Smoke Control Ducts and Dampers For Single Compartment Applications Fulfilling new requirements for EN product standards for CE Marking New Smoke Control Product Range Fläkt Woods Smoke Control Ducts and

More information

ESAR SMOKE CONTROL DAMPER» TECHNICAL CATALOGUE

ESAR SMOKE CONTROL DAMPER» TECHNICAL CATALOGUE FIRE SAFETY AIR TREATMENT FIRE DAMPERS ESAR SMOKE CONTROL DAMPER» TECHNICAL CATALOGUE 2 ESAR Smoke control damper Technical catalogue Circular smoke control damper ESAR is specially designed to use in

More information

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION Swegon CASA R120 Ventilation unit with rotary heat exchanger Ventilation unit for residential houses, multi-storey buidings and holiday cottages under 230 m 2. The unit is equipped with rotary heat exchanger.

More information

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING A Better Life. A Better World Please read the Installation Instructions carefully before installing the unit, and the Operating Instructions before using it. Specifications are subject to change without

More information

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING PANASONIC LEADS THE WAY Ducted Air Conditioning Specialists With more than 60 years of experience, exporting to more than 120 countries around the world,

More information

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc. System Components with ` Emphasis on Packaged Rooftop Application and Installation Jerry Cohen President Jacco & Assoc. Agenda Define and relate in practical terms the following components: System Effect

More information

The Art of Building Science

The Art of Building Science The Art of Building Science What is Building Science? Building Science seeks to apply the scientific fundamentals of building dynamics to the functional relationships between the house s components and

More information

Residential and Light Commercial Ductless Systems Catalog

Residential and Light Commercial Ductless Systems Catalog Residential and Light Commercial Ductless Systems Catalog May 2018 Table of Contents Midea Global 3 Ductless Benefits 5 Single and Multi-Zone Solutions 9 Single Zone Residential 13 Max Series 15 Advantage

More information

Flexit air handling units C2 and UNI 2, 3,4

Flexit air handling units C2 and UNI 2, 3,4 Flexit handling units C2 and UNI 2, 3,4 energy efficient ventilation for a healthy indoor environment A FOR A HEALTHY INDOOR ENVIRONMENT Energy-efficient ventilation Flexit C2 and UNI 2, 3, 4 The handling

More information

Flexit air handling units UNI 2, 3 og 4

Flexit air handling units UNI 2, 3 og 4 Flexit handling units UNI 2, 3 og 4 energy efficient ventilation for a healthy indoor environment FOR A HEALTHY INDOOR ENVIRONMENT Energy-efficient ventilation Flexit UNI 2, 3 and 4 The handling units

More information

Development of Predictive Maintenance Management System for tackling airborne infection in Healthcare Facilities

Development of Predictive Maintenance Management System for tackling airborne infection in Healthcare Facilities Development of Predictive Maintenance Management System for tackling airborne infection in Healthcare Facilities Dr Ghasson Shabha,BSc MSc (Arch Eng) PhD (Arch), Associate CIBSE, MBIFM, PG Cert Ed., IOSH

More information

X-Stream Air Natural Ventilation kits are predominantly designed for self-installation. Suitable for ventilating existing and new build applications.

X-Stream Air Natural Ventilation kits are predominantly designed for self-installation. Suitable for ventilating existing and new build applications. X- StreamSystems X-Stream Air Natural Ventilation kits are predominantly designed for self-installation. Suitable for ventilating existing and new build applications. Contact us on: 01384 455811 Visit

More information

Swegon PACIFIC. Integrated chilled beam PACIFIC CHILLED BEAM KEY FIGURES

Swegon PACIFIC. Integrated chilled beam PACIFIC CHILLED BEAM KEY FIGURES Swegon PACIFIC Integrated chilled beam PACIFIC CHILLED BEAM The PACIFIC is a high performance chilled beam for installation in false ceilings. Built-in flexibility, designed to meet the needs of today

More information