General catalogue 2016

Size: px
Start display at page:

Download "General catalogue 2016"

Transcription

1 The energetic solutions of Parkair General catalogue

2 Parkair offers a wide range of energy solutions to meet the needs of your projects. Ongoing innovation with cutting-edge products 30 Over 30 years of experience Production 100% Made in Italy Guaranteed support and spare parts Support in design Documentation for incentives 2 Two-year guarantee Free training course 2

3 Company profile Parkair, Italian company set up in the 1970s has established itself as a market leader, supplying high quality and reliable products; it entered the conditioning sector in 2001 devoting special attention to designing and producing water-condensed and low energy consumption conditioning appliances. In a short time it developed a wide range of products, unique in range and reliability, that establish themselves on the market as successful Italian products. While maintaining the positive features of Italian handicraft firm, always with an eye to detail, producing customised products that meet any requirement, Parkair is today a small industrial concern, that has been on the market for over 30 years and boast significant experience in the air handling sector. These years of experience have led the company to respecting very clearly defined values: Low energy consumption systems Use of clean energy Use of environmentally-friendly cooling gases ZERO direct CO2 emissions in the environment Parkair operates in a strongly impacting sector in the energy field, and its primary objectives include committing resources to continuous technological research and improvement of production processes, with the aim of streamlining products and raise users awareness on the actual soundness of ensuing energy savings. Furthermore, in perfect harmony with the requirements of the European Community, Parkair products only and exclusively use R410A and R134A environmentally-friendly gas. The sales office, production facility and warehouse are located just 5km from Milan, and this assures spare parts are always available, products are in stock and promptly and easily delivered nationally as well as abroad. 1

4 2

5 Index of the General Catalogue Why choosing a Parkair water split system? Water natural cycle Let s get to know a Heat Pump Geothermal Energy Policy and the Erp directive Heat pumps for domestic hot water production Compact systems Water-to-Water WALLY Acqua Compact systems Air-to-Water WALLY Aria Monoblock systems Air-to-Water HPA Split systems Air-to-Water HPA-S Direct Expansion systems Water condensing units ACW Monosplit Cooling and Heat Pump Water-to-Air Water condensing units ACW Multisplit Only Cooling Water-to-Air Wall mounted split units WI-G Ducted split units DI-M Cassette split units KI-M Floor and Ceiling split units FI-M Hydronic systems Chillers and Heat Pump Water-to-Water RCW Heat Pump Air-to-Water RCA Wall fancoils FCW Ducted fancoils FCD Recessed fancoils FCI Cassette fancoils FCK Functionality legend Remote controllers RC-G, RC-M Notes 3

6 The choice of water as renewable energy Why choosing a Parkair water split system? Parkair s ACW Water Condensing Units offer an alternative to traditional air conditioning systems, replacing the outer unit with compact-sized units and with no need to make any holes on the façade of the building. The unit may be installed in any room in a building, the only requirement being that of providing a water inlet and drain like a normal sink. This feature allows it to be installed in the event of architectural, planning, aesthetic and building regulations constraints. They are therefore ideal also for architecturally valuable buildings, whose façades cannot be spoiled by an air conditioning unit or for all those buildings whose regulations does not allow installation. They are the ideal solution for all those who until now thought they would not be able to install an air conditioning unit in their house or business. They are also excellent for all those who wish to reap the maximum possible savings. In fact, in addition to assuring savings and reducing consumption, water also makes it possible to achieve greater efficiency than conventional air systems. Water condensation systems assure the best performance in any environmental condition as water temperature is subject to minimal variations compared to air. In addition to water taken from the municipal water mains, all Parkair ACW Water Condensing Units are suited to operation with well or table water, and in closed loop systems. When should one use our ACW split systems? When you wish to have considerable cost savings thanks to the use of water which assures better performance with lower energy consumption. When there is no external space available. If the building regulations forbid application on the façade or balconies of conventional external motors. To avoid quarrelling with the neighbours due to the noise level of external motors. Or to safeguard the aesthetics of building façades. 4

7 Water s natural cycle One of the cleanest and most efficient energy sources in the world, clean and renewable The continuous availability of water in its various forms is due to the existence of a natural cycle, complex yet perfect, sustained by solar energy and the force of gravity. In this framework water is cyclically purified by effect of evaporation, the ground s filtering power and biological self-purification mechanisms of water bodies. The sun is the water cycle s engine. Its heat causes the evaporation of the large masses of water in seas and oceans, which then condense and fall back on the ground as rain or snow. In this way glaciers, snowfields, streams, rivers, lakes and aquifers will be fed. The water flows into the sea again and initiates a new cycle. During the cycle only pure water evaporates, in fact the minerals and other substances dissolved in it are deposited, thus causing the saltness of seawater: the process is therefore a sort of distillation powered by the sun, which has the effect of purifying water. As this process is continuously renewed, water represents a renewable energy source. Condensatiion Precipitatiion Capture Evaporatiion Filtratiion Filtratiion Release Domestiic Use 5

8 A technology that contributes to environmental sustainability Let s get to know a Heat Pump The heat pump is able to meet all the needs of a room s conditioning and heating, assuring the comfort and well-being of the people living or working there. The heat pump is in fact a machine able to transfer energy from a low temperature environment to a higher temperature system. With the same procedure through which a pump raises a fluid from a lower level to a higher one, the heat pump, using a single system, heats and cools the rooms in a home or workplace, in addition to producing domestic hot water for the daily requirements. A heat pump system is therefore able to meet all the air conditioning and heating requirements of a room, assuring the comfort and well-being of the people living or working there. It is a technology that contributes to environmental sustainability and the reduction of energy consumption, with cost savings in electricity bills and a return on investment in the short term, thanks to government incentives and advantages one is able to benefit from. One may say that, from the energy point of view, the process at the basis of a heat pump is always cost effective: 1 kwh of electricity yields up to 5 kwh thermal energy. The energy obtained is therefore always greater than the one used. A heat pump system, finally, increases the market value of the building, also for the aims of property sale, as it contributes to increasing the building s energy class. Low cost, clean energy 6

9 Heating, cooling and domestic hot water at low costs Geothermal The ground contains an inexhaustible source of heat: the temperature, as you go deeper underground, increases thanks to geothermal energy directed toward the surface from the earth s core; the ground also absorbs nearly half the energy it receives from the sun. As a result only a few metres below the earth s surface, the ground maintains a constant temperature throughout the year and this allows us to extract heat in winter to heat a room and release heat during the summer to cool the same room in a natural and clean manner, using a free and renewable heat source. Such heat exchange is carried out with heat pumps combined with geothermal or ground water probes which, exploiting these principles, allow our homes to be heated and cooled, retrieve hot water for domestic use with a single system and with low electricity consumption. Parkair s GEO heat pump is the efficient, effective and environmentally friendly alternative to completely replace a conventional system. The probes in deep contact with the ground receive or release energy depending on the time of year and the production demand, providing to the heat pump what it needs to operate the system and achieve the desired result. Room heating (20/22 C), Cooling (26 C) and Domestic Hot Water production throughout the year. The advantages in using GEO? It makes you independent from oil and gas prices Environmentally friendly since it does not emit CO2 and there are no external units Quiet Perfectly integrated with other conventional heating systems or renewable energies Assures high yield Installation costs are amortised in less than 5 years Savings up to 40% for heat production Eliminates maintenance costs 7

10 Our commitment for a better energy Energy policy for the plan The aim is obviously to counter climate change and foster the use of renewable energy sources through binding objectives for member States. Parkair has a duty to supply high performance products to reduce the environmental impact, adapting to results in view of the European 2020 efficiency target. Parkair s catalogue is in fact able to meet the requirements of all European Regulations currently in force. -20% CO 2 Reducing Greenhouse Gas emissions +20% Raising the share of energy produced from renewable sources -20% Reducing Energy Consumption There must be a better way to make the things we want, a way that doesn t spoil the sky, or the rain, or the land Paul McCartney 8

11 For intelligent, sustainable and inclusive growth The ErP directive: new values for consumptions The 2009/125/EC Directive Energy-related-Products - ErP also known as Eco-design is a re-formulation of Directive 2005/32/EC (Energy-Using-Products - EuP) and is in actual fact a framework directive that will govern the eco-design requirements for all products that use energy - except those intended for the transport sector - through specific implementing regulations. This directive represents the most important initiative undertaken by the EU to improve energy efficiency by 20% by the year This is the first directive that regards the entire product s life cycle, in fact it includes requirements for the following sectors of products and services: Acquisition of raw materials Production Transport and commerce Use and maintenance Reuse/recycle/treatment at the end of the life cycle As of November 2009, the following groups of products have been the recipients of separate regulations and must meet the requirements of this directive: Boilers (gas/diesel/electricity) Consumer electronics (TV sets) Energy losses in stand-by and off mode of erps Battery chargers and external feeders Office lighting Road lighting (public) Electrical motors Standalone and glandless circulators Refrigerators and freezers for household use Simple decoders Household lighting A great project to be implemented for our future 9

12 Low cost hot domestic water from renewable energy The technology of the heat pump is becoming more prominent in the domestic industry in applications dedicated to the production of domestic hot water (DHW). It allows considerable energy savings - and cheap - compared to electric resistance systems and also offers advantages over combustion systems. The savings can be even higher than 75%

13 Heat Pump for Domestic Hot Water Production WALLY Acqua Compact systems Water-to-Water WALLY Aria Compact systems Air-to-Water HPA Monoblock system Air-to-Water HPA-S Split system Air-to-Water BHP Buffer tanks for DHW using the Heat Pumps HPA-S

14 Heat Pump for DHW production WALLY Acqua Compact system Water-to-Water wall or floor application MONOBLOCK CAPACITY FROM 30LT UP TO 120LT WITHOUT EXTERNAL UNITS OR CONNECTIONS EASY INSTALLATION LOW NOISE COMPACT DESIGN ANTILEGIONELLA CYCLE Functional specs Main features It efficiently produces domestic hot water using the well established heat pump technology together with water condensation. The high performance makes it possible to obtain significant benefits with the lowest environmental and economic impact. In fact thanks to COP 3.9 electrical consumption is over 75% lower than conventional water boilers. Installing the DHW heat pump WALLY Acqua is easy and far from demanding. The ease of installation, quiet and reliable operation and moderate maintenance requirements complement the advantages of this very environmentally-friendly and economic system. The machine s control periodically activates high temperature sanitising cycles to prevent the formation of hazardous bacteria for human health. 12 The coolant fluid used in the heat pump is R134A which thanks to high thermodynamic features assures optimum performance. Furthermore, it is not harmful to the ozone layer, it contains no chlorine, it is neither toxic nor flammable, to the advantage of safety both for the user and installer.

15 Functional scheme Oultet hot water Drain water of heat exchanger Inlet tap water Where to install it? Bathroom Kitchen Laundry Safety bar 7 Bar Some additional information... 75% 60 C 35% COP=3.9 GAS R134A The energy saving compared to a classic electric water heater. Technical data Maximum water temperature. The energy saving compared to a classic condensing boiler. Energy efficiency among the highest in the market for heat pump water heaters. Ecological refrigerant guarantees high yields. Compact systems for DHW production Water-to-Water WALLY Acqua Model WALLY-30WSK WALLY-30WS WALLY-50WS WALLY-70WS WALLY-80WS WALLY-120WS Kit KF-30WS Kit KF-80WS Code Capacity litri Number of accumulations Nr Heating capacity (electrical resistance) kw 0,85 0,85 0,85 0,85 0,85 0, Heating capacity (compressor) kw 1,30 1,30 1,30 1,30 1,30 1, Total heating capacity kw 2,15 2,15 2,15 2,15 2,15 2, Maximum absorption PDC kw 0,58 0,58 0,58 0,58 0,58 0, Average power consumption kw 0,49 0,49 0,49 0,49 0,49 0, Dimensions (WxDxH) mm 320x480x x310x x310x x310x x320x x320x x310x x320x250 Weight (Net/Gross) Kg 48/78 42/72 52/102 60/130 72/152 88/ Maximum water pressure bar Maximum water temperature C 35,00 35,00 35,00 35,00 35,00 35, Minimum water temperature C Nominal water flow mc/h 0,23 0,23 0,23 0,23 0,23 0, Maximum water flow mc/h 0,46 0,46 0,46 0,46 0,46 0, Power supply V-Hz 230 V 50Hz 230 V 50Hz 230 V 50Hz 230 V 50Hz 230 V 50Hz 230 V 50Hz - - Protection class - IP X4 IP X4 IP X4 IP X4 IP X4 IP X4 - - Sound power Lw (A) db(a) Legionella system 70 C Automatic - - Operating mode - Auto-Eco-Boost - - Heating time (according to EN 16147) hh:mm 01:12 01:12 01:58 02:44 03:12 05: Heating time w/ BOOST mode (according to EN 16147) hh:mm Unit testing - - Copt (according to EN 16147) - 3,5 3,5 3,6 3,7 3,9 3,9 - - Performances referred to the following conditions: Water inlet temperature 15 C, the storage room temperature boiler 20 C, heating water from 10 C up to 55 C. 13

16 Heat Pump for DHW production WALLY Aria Compact system Air-to-Water wall or floor application MONOBLOCK CAPACITY FROM 30LT UP TO 120LT WITHOUT EXTERNAL UNITS OR CONNECTIONS EASY INSTALLATION LOW NOISE COMPACT DESIGN ANTILEGIONELLA CYCLE Functional specs Main features It efficiently produces domestic hot water using the well established heat pump technology together with water condensation. The high performance makes it possible to obtain significant benefits with the lowest environmental and economic impact. In fact thanks to COP 3.4 electrical consumption is over 75% lower than conventional water boilers. Installing the DHW heat pump WALLY Aria is easy and far from demanding. The ease of installation, quiet and reliable operation and moderate maintenance requirements complement the advantages of this very environmentally-friendly and economic system. The machine s control periodically activates high temperature sanitising cycles to prevent the formation of hazardous bacteria for human health. 14 The coolant fluid used in the heat pump is R134A which thanks to high thermodynamic features assures optimum performance. Furthermore, it is not harmful to the ozone layer, it contains no chlorine, it is neither toxic nor flammable, to the advantage of safety both for the user and installer.

17 Functional scheme Outlet cold water Outlet hot water Condensing drain water Safety valve 7 Bar Where to install it? Bathroom Kitchen Inlet tap water Laundry Inlet ambience air Some additional information... 75% 60 C 35% COP=3.4 GAS R134A The energy saving compared to a classic electric water heater. Technical data Maximum water temperature. The energy saving compared to a classic condensing boiler. Energy efficiency among the highest in the market for heat pump water heaters. Ecological refrigerant guarantees high yields. Compact systems for DHW production Air-to-Water WALLY Aria Model WALLY-30AS WALLY-50AS WALLY-70AS WALLY-80AS WALLY-120AS Kit KF-30AS Kit KF-80AS Code Capacity litri Number of accumulations Nr Heating capacity (electrical resistance) kw 0,85 0,85 0,85 0,85 0, Heating capacity (compressor) kw 1,00 1,00 1,00 1,00 1, Total heating capacity kw 1,85 1,85 1,85 1,85 1,85 Maximum absorption PDC kw 0,350 0,350 0,350 0,320 0, Average power consumption kw 0,270 0,270 0,270 0,270 0, Dimensions (WxDxH) mm 327x310x x310x x310x x320x x320x x310x x320x250 Weight (Net/Gross) Kg 48/78 55/105 62/132 76/156 91/ Maximum water pressure bar Maximum air temperature C Minimum air temperature C Nominal airflow mc/h Cubic environment requirement mc Power supply V-Hz 230 V 50Hz 231 V 50Hz 232 V 50Hz 233 V 50Hz 233 V 50Hz - - Protection class - IP X4 IP X5 IP X6 IP X7 IP X7 - - Sound power Lw (A) db(a) ,2 56,2 - - Legionella system 70 C Automatic - - Operating mode - Auto-Eco-Boost - - Heating time (according to EN 16147) hh:mm 01:43 02:57 04:18 04:34 06: Heating time w/ BOOST mode (according to EN 16147) hh:mm 0:52 01:27 03:03 02:33 03: Copt (according to EN 16147) - 2,70 2,70 2,70 2,70 2, Performances referred to the following conditions: Air inlet temperature 7 C, R.H. 87%, storage room temperature boiler 20 C, heating water from 10 C up to 55 C. 15

18 Heat Pump for DHW production HPA Monoblock systems Air-to-Water MONOBLOCCO COMPRESSORE AD ALTA EFFICIENZA INTEGRAZIONE AL FOTOVOLTAICO RISPARMIO ECONOMICO ED ENERGETICO FACILE INSTALLAZIONE ELEVATA SILENZIOSITà DESIGN COMPATTO CICLO ANTILEGIONELLA Functional specs Main features Produce in modo efficiente acqua calda sanitaria utilizzando la consolidata tecnologia delle pompe di calore. Le prestazioni elevate consentono di ottenere importanti benefici con il minor impatto ambientale ed economico. Infatti grazie ai COP fino al 3.1 i consumi elettrici si riducono di oltre il 75% rispetto ai tradizionali scaldabagni. Installare uno scaldacqua monoblocco a pompa di calore HPA è facile e non impegnativo. La facilità d installazione, il funzionamento silenzioso ed affidabile e la moderata esigenza di manutenzione completano i vantaggi di questo sistema altamente ecologico ed economico. Il controllo della macchina attiva periodicamente cicli di sanificazione ad alta temperatura per prevenire la formazione di batteri pericolosi per la salute umana. 16 Il fluido refrigerante utilizzato nella pompa di calore è l R134A che grazie ad elevate caratteristiche termodinamiche garantisce ottimi rendimenti. Inoltre non è dannoso allo strato di ozono, non contiene cloro, non è tossico né infiammabile, a tutto vantaggio della sicurezza sia per l utilizzatore che per l installatore.

19 Where to install it? Nel mobile bagno Garage Locale tecnico Lavanderia The serie HPA Inlet air ambience Outlet cold air HPA-200 HPA-260 HPA-90 Technical data Monoblock systems for DHW production Air-to-Water HPA Model HPA-90 HPA-200 HPA-260 Code Capacity litri Installation - Hanging Floor Floor Heating capacity (electrical resistance) kw 1,2 1,5 1,5 Average electrical power matched kw 0,21 0,37 0,37 Heating capacity (compressor) kw 1,0 1,6 1,6 Total heating capacity kw 2,2 3,1 3,1 Maximum absorption PDC kw 0,27 0,50 0,50 Average power consumption kw 0,21 0,37 0,37 Absorption PDC w/ electrical resistance kw 1,47 2,0 2,0 Dimensions (Diameter x Height) mm 500x x x2000 Weight (Net/Gross) Kg 46/ / /375 Maximum water pressure bar Maximum air temperature C 43,0 43,0 43,0 Minimum air temperature C 4,0 4,0 4,0 Nominal airflow mc/h Cubic environment requirement mc Power supply V-Hz 230 V 50Hz 231 V 50Hz 232 V 50Hz Protection class - IP X4 IP X5 IP X6 Refrigerant - R134A R134A R134A Charge of refrigerant gr Sound power inside Lw (A) db(a) Sound power outside Lw (A) db(a) Legionella system 70 C Operating mode - Heating time (according to EN ) hh:mm 05:30 07:16 09:44 Heating time w/ BOOST mode (according to EN ) hh:mm 02:25 03:48 04:57 Copt (according to EN 16147) - 2,8 2,8 3,1 Coil (condenser) wrapped - YES YES YES Internal coil for solar - NOT YES YES Performances referred to the following conditions: Air inlet temperature 20 C (15 C max), the storage room temperature boiler 20 C, heating water from 10 C up to 55 C. Automatic Auto-Eco-Boost 17

20 Heat Pump for DHW production & Buffer Tanks HPA-S Split systems Air-to-Water SISTEMA AUTO-DEFROSTING GAS ECOLOGICO R134A FACILE INSTALLAZIONE ELEVATA SILENZIOSITà DESIGN COMPATTO CICLO ANTILEGIONELLA Functional specs Main features The Heat Pump HPA-S is the innovative treatment unit to combine with an external storage to renew the central production of sanitary hot water, ideal in renovation projects. HPA-S is equipped with two temperature probes to be inserted in the accumulation remote. The electronic control of the HPA-S is also programmed to drive a circulation resistance. Buffers The BHP series boilers are designed with large exchange surface coil enamelled to obtain large production of hot water. The long life of the tank is ensured by the opal glass at about 850 C made according to DIN 4753 and magnesium anode to corrosion. The polyurethane foam insulation of 50mm thick CFC and HCFC-free, ensures excellent insulation. The outer cover is made by wrapping the tank with a cape with vinyl, PVC or PE wire. 18

21 The tanks are equipped with the following attacks: Side flange 110mm, for inspection and possible installation of the heating unit; Connection for recirculation; Connection ø1 / 2 g for eventual installation of the heating unit; Connection ø1 / 2 g for installation of previously thermostat; Connection ø1 / 2 g for insertion thermometer. Functional scheme Inlet air ambience Outlet cold air HPA-S Hot water BHP Technical data Split systems for DHW production Air-to-Water HPA-S Model HPA-S2 HPA-S3 Code Maximum power of the electrical resistance (NOT INCLUDED) kw 1,5 1,5 Average electric power input kw 0,43 0,67 Heating capacity kw 1,9 2,9 Dimensions (WxDxH) mm 680x500x x500x496 Weight kg Maximum water pressure bar 7 7 Maximum air temperature C Minimum air temperature C -7-7 Nominal airflow mc/h 350/ /700 Power supply parameters V - Hz 230V 50Hz 230V 50Hz Protection class - IP X4 IP X4 Sound power inside Lw (A) db(a) Operating mode - Auto-Eco-Boost Auto-Eco-Boost Automatic cycle legionella - YES YES Heating time (according to EN ) hh:mm 08:29 05:44 Copt (according to EN ) - 2,9 2,8 Refrigerant - R134A R134A Refrigerant charge Kg 0,57 0,66 Recirculation pump - NOT NOT Temperature probes for external accumulation - 2 included Buffer tanks for DHW production BHP Model BHP-150 BHP-200 BHP-200-DS BHP-300 BHP-300-DS Code Buffer volume litri Maximum operating pressure Bar Maximum operating temperature C Production water DT = 35 C (80/60-10/45) mc/h 0,4 0,7 0,7 0,9 0,9 Extent necessary to coil mc/h 0,6 1,1 1,1 1,6 1,6 Surface coil exchange mq. 0,6 1,1 1,1 1,5 1,5 Total height mm External diameter (with insulation) mm Inner diameter (without insulation) mm Cold water " 1" 1" 1" 1" 1" Heating return " 1" 1/4 1" 1/4 1" 1/4 1" 1/4 1" 1/4 Heating probe " 1/2" 1/2" 1/2" 1/2" 1/2" Heating flow " 1" 1/4 1" 1/4 1" 1/4 1" 1/4 1" 1/4 Recirculation " 3/4" 3/4" 3/4" 3/4" 3/4" Hot water " 1" 1" 1" 1" 1" Electrical resistance " 1" 1/2 1" 1/2 1" 1/2 1" 1/2 1" 1/2 Thermometer " 1/2" 1/2" 1/2" 1/2" 1/2" Serpentine integration solar system - NO NO SI NO SI Performances referred to the following conditions: Air inlet temperature 20 C (15 C max.), storage room temperature boiler 20 C, heating water from 10 C up to 55 C. The tests were carried out on a 260 liter tank with coil with an area of 1 m2, 50mm of insulation. 19

22 Cooling and Heating without any external units and without any external links or holes in facade. The ideal solution for all those who believed until today to be not able to install an HVAC system in their home or business.

23 Direct Expansion systems for Cooling and Heating, Mono and Multi Splits. ACW Monosplit Water condensing units Cooling and Heat Pump ACW Multisplit Water condensing units Only Cooling WI-G Wall Mounted split units DI-M Ducted split units KI-M Cassette split units FI-M Floor and Ceiling split units

24 Cooling and Heat Pump ACW Monosplit Water condensing units in direct expansion Water-to-Air H2O-INVERTER SYSTEM RANGE FROM 3KW TO 23KW ONLY COOLING OR HEAT PUMP ECO FRIENDLY GAS R410A LOW NOISE Functional specs Main features H2O Inverter system All the models are provided with with modulating valve for limiting water consumption and equipped with a PLC (Programmable Logic Controller) for the automatic control of all functions. quiet operation Thanks to the use of panels with thermal and acoustic insulation units are particularly silent even if installed in close proximity to domestic environments. Simple and compact design The structure is made from a multiple housing sheet steel painted with epoxy powder color Pure White and removable side panels covered with soundproofing material. Easy installation and system management The front inspection panel allows easy access to internal components and a quick link to the appropriate service valve gauges for measuring pressures making it easier handling, installation and any subsequent action. 22

25 Where to install it? Bathroom Kitchen Ceiling Understairs Componenti Electronic controller PLC Modulating valve Compressors R410A Rotativi & Scroll Technical data Water Condensing Units ACW - Monosplits - Only Cooling Model ACW-9 ACW-12 ACW-18 ACW-24 ACW-30 ACW-32T ACW-40T ACW-50T ACW-60T Code Cooling capacity BTU/h kw 2,63 3,71 5,20 8,00 8,35 9,65 11,00 15,96 18,74 Power supply V Power consumption kw 0,67 0,84 1,15 1,80 1,90 2,62 2,70 3,48 4,16 EER kw/kw 3,93 4,42 4,52 4,44 4,39 3,68 4,07 4,58 4,50 Water flow (15 C) mc/h 0,14 0,19 0,28 0,38 0,50 0,50 0,63 0,79 0,94 Water flow (Temp. Ev.) (29-34 C) mc/h 0,48 0,63 0,95 1,20 1,60 1,60 2,10 2,60 3,10 Water connections (G) " 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 Refrigerant pipe ø (Liquid/Gas side) " 1/4-3/8 1/4-1/2 1/4-1/2 3/8-5/8 3/8-5/8 3/8-3/4 3/8-3/4 3/8-3/4 3/8-3/4 mm 6,35-9,52 6,35-12,7 6,35-12,7 9,52-15,9 9,52-15,9 9,52-19,0 9,52-19,0 9,52-19,0 9,52-19,0 Max. length refrigerant connection mt Max. height difference w/ splits mt Refrigerant - R410A R410A R410A R410A R410A R410A R410A R410A R410A Sound level dba Weight Kg Dimensions (WxDxH) mm 460x420x x420x x420x x420x x505x x505x x505x x505x x505x550 Water Condensing Units ACW - Monosplits - Heat Pump Model ACW-9H ACW-12H ACW-18H ACW-24H ACW-30H ACW-32TH ACW-40TH ACW-50TH ACW-60TH Code Cooling capacity Heating capacity BTU/h kw 2,63 3,71 5,20 8,00 8,35 9,65 11,00 15,96 18,74 BTU/h kw 3,30 4,62 6,40 9,40 10,20 12,49 13,76 19,35 22,74 Power supply V Power consumption kw 0,75 0,98 1,33 1,98 2,28 3,21 3,30 4,29 5,17 EER kw/kw 3,93 4,42 4,52 4,44 4,39 3,68 4,07 4,59 4,50 COP kw/kw 4,40 4,71 4,81 4,74 4,47 3,89 4,17 4,51 4,40 Water flow - cooling mc/h 0,14 0,19 0,28 0,38 0,50 0,50 0,63 0,79 0,94 Water flow - heating mc/h 0,48 0,63 0,95 1,20 1,60 1,60 2,10 2,60 3,10 Water connections (G) " 3/4 3/4 3/4 3/ Refrigerant pipe ø (Liquid/Gas side) " 1/4-3/8 1/4-1/2 1/4-1/2 3/8-5/8 3/8-5/8 3/8-3/4 3/8-3/4 3/8-3/4 3/8-3/4 mm 6,35-9,52 6,35-12,7 6,35-12,7 9,52-15,9 9,52-15,9 9,52-19,0 9,52-19,0 9,52-19,0 9,52-19,0 Max. length refrigerant connection mt Max. height difference w/ splits mt. 5,00 5,00 8,00 8,00 10,00 10,00 10,00 10,00 10,00 Refrigerant - R410A R410A R410A R410A R410A R410A R410A R410A R410A Sound level dba Weight Kg Dimensions (WxDxH) mm 460x420x x420x x420x x420x x505x x505x x505x x505x x505x550 Performances refer to the following conditions: COOLING: Temp. 27 C ambient air B.S., 19 C B.U. / Inlet water temperature 15 C - HEATING: Air temp. 20 C. / IN-OUT water temperature 12-7 C. The cooling capacity and the electric absorption indicated are given at 5 C and 40 C condensation evaporation. Min water temperature in heat pump operation 10 C. The sound pressure is measured at 1 mt. away from the external surface of the unit in open field. See the table Corrosion Resistance contained in the booklet ACW instructions (download from our website) to verify the employment eligibility according to water quality. The flow rate of water with cooling tower is calculated with values of temperature 29/34 C. 23

26 Only cooling ACW Multisplit Water condensing units in direct expansion Water-to-Air H2O-INVERTER SYSTEM RANGE FROM 3KW TO 16KW UP TO 4 INDOOR UNITS ECO FRIENDLY GAS R410A LOW NOISE Functional specs Main features H2O Inverter system All the models are provided with with modulating valve for limiting water consumption and equipped with a PLC (Programmable Logic Controller) for the automatic control of all functions. quiet operation Thanks to the use of panels with thermal and acoustic insulation units are particularly silent even if installed in close proximity to domestic environments. Simple and compact design The structure is made from a multiple housing sheet steel painted with epoxy powder color Pure White and removable side panels covered with soundproofing material. Easy installation and system management The front inspection panel allows easy access to internal components and a quick link to the appropriate service valve gauges for measuring pressures making it easier handling, installation and any subsequent action. 24

27 Where to install it? Bathroom Kitchen Ceiling Understairs Componenti Electronic controller PLC Modulating valve Compressors R410A Rotativi & Scroll Technical data Water Condensing Units ACW - Dual splits - Only Cooling Model 9/9 12/12 9/9 BC 9/12 BC 9/18 BC 9/24 BC 12/12 BC 12/18 BC 12/24 BC 18/18 BC Code Cooling capacity BTU/h kw 3,71 5,20 5,26 6,34 7,83 10,63 7,42 8,91 11,71 10,40 Power supply V Power consumption kw 0,84 1,15 1,34 1,51 1,82 2,47 1,68 1,99 2,64 2,30 EER kw/kw 4,42 4,52 3,92 4,20 4,30 3,64 4,42 4,48 4,44 4,52 Portata acqua (15 C) mc/h 0,19 0,28 0,14+0,14 0,14+0,19 0,14+0,28 0,14+0,38 0,19+0,19 0,19+0,28 0,19+0,38 0,28+0,28 Water flow - Cooling tower mc/h 0,63 0,95 0,48+0,48 0,48+0,63 0,48+0,95 0,48+1,2 0,63+0,63 0,63+0,95 0,63+1,2 0,95+0,95 Water connections (G) " 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 Refrigerant pipe ø (Liquid/Gas side) " 1/4-3/8 1/4-1/2 1/4-3/8 1/4-3/8+1/4-1/2 1/4-3/8+1/4-1/2 1/4-3/8+3/8-5/8 1/4-1/2 1/4-1/2 1/4-1/2+3/8-5/8 1/4-1/2 mm 6,35-9,52 6,35-12,7 6,35-9,52 6,35-9,52+6,35-12,7 6,35-9,52+6,35-12,7 6,35-9,52+9,52-15,9 6,35-12,7 6,35-12,7 6,35-12,7+9,52-15,9 6,35-12,7 Max. length refrigerant connection mt Max. height difference w/ splits mt Refrigerant - R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A Sound level dba Weight Kg Dimensions (WxDxH) mm 460x420x x420x x505x x505x x505x x505x x505x x505x x505x x505x550 Water Condensing Units ACW - Dual, Trial, Quadri splits - Only Cooling Model 18/24 BC 24/24 BC 9/9/9 9/9/12 9/9/18 9/12/12 12/12/12 9/9/9/9 9/9/12/12 12/12/12/12 Code Cooling capacity BTU/h kw 13,20 16,00 6,34 7,42 8,91 7,83 8,91 7,42 8,91 10,40 Power supply V Power consumption kw 2,95 3,60 1,51 1,68 1,99 1,82 1,99 1,68 1,99 2,30 EER kw/kw 4,47 4,44 4,20 4,42 4,48 4,30 4,48 4,42 4,48 4,52 Portata acqua (15 C) mc/h 0,28+0,38 0,38+0,38 0,19+0,14 0,19+0,19 0,19+0,28 0,14+0,28 0,28+0,19 0,19+0,19 0,19+0,28 0,28+0,28 Water flow - Cooling tower mc/h 0,95+1,2 1,2+1,2 0,63+0,48 0,63+0,63 0,63+0,95 0,48+0,95 0,95+0,63 0,63+0,63 0,63+0,95 0,95+0,95 Water connections (G) " 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 Refrigerant pipe ø (Liquid/Gas side) " 1/4-1/2+3/8-5/8 3/8-5/8 1/4-3/8 1/4-3/8+1/4-1/2 1/4-3/8+1/4-1/2 1/4-3/8+1/4-1/2 1/4-1/2 1/4-3/8 1/4-3/8+1/4-1/2 1/4-1/2 mm 6,35-12,7+9,52-15,9 9,52-15,9 6,35-9,52 6,35-9,52+6,35-12,7 6,35-9,52+6,35-12,7 6,35-9,52+6,35-12,7 6,35-12,7 6,35-9,52 6,35-9,52+6,35-12,7 6,35-12,7 Max. length refrigerant connection mt Max. height difference w/ splits mt ,00 5,00 5,00 5,00 5,00 5,00 5,00 5,00 Refrigerant - R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A Sound level dba Weight Kg Dimensions (WxDxH) mm 485x505x x505x x505x x505x x505x x505x x505x x505x x505x x505x550 Performances refer to the following conditions: COOLING: Temp. 27 C ambient air B.S., 19 C B.U. / Inlet water temperature 15 C. The cooling capacity and the electric absorption indicated are given at 5 C and 40 C condensation evaporation. Min water temperature in heat pump operation 10 C. The sound pressure is measured at 1 mt. away from the external surface of the unit in open field. See the table Corrosion Resistance contained in the booklet ACW instructions (download from our website) to verify the employment eligibility according to water quality. The flow rate of water with cooling tower is calculated with values of temperature 29/34 C. 25

28 Wall mounted split units WI-G RANGE FROM 2,7KW UP TO 8KW NEW MODERN DESIGN ECO FRIENDLY GAS R410A LOW NOISE Functional specs Main features Elegant and essential design A perfect balance of aesthetics and functionality, soft and neat lines that stylishly complement any internal setting. The unit stands out for the quality of the materials and superior level of finishes such as the hidden display. Sleep Care The Sleep Care function is a precise and intelligent technology for the night. It provides different setting modes for every type of users, such as adults, children and the elderly. Thanks to this function your sleep will certainly improve. Low noise Thanks to quiet operation, the unit distributes air in the room in an almost imperceptible manner, emitting minimal noise at a level of 20 db(a). In addition to the possibility of controlling the air flow output volume, a larger diameter fan reduces the internal unit s noise level thus further reducing fan speed and optimising the air flow. 26

29 Design Special notes Remote controller RC-G (included) Backlit Display Easy Interface Double design surface Ideal applications Residences Offices Shops Bars & restaurants Technical data Wall mounted split units WI-G Model WI9-G WI12-G WI18-G WI24-G Code Power supply V-ph-Hz Cooling capacity Heating capacity Btu/h Btu/h KW KW 2,70 2,85 3,50 3,80 4,50 5,00 7,10 7,80 Input Power w Fan Motor Speed (Hi/Med/Lo) r/min 1250/1050/ /1220/ /1150/ /1150/1050 Air flow (Hi/Med/Lo) m3/h 450/400/ /450/ /700/ /980/880 Noise level (Hi/Med/Lo) db(a) 40/37/34 40/37/34 43/40/37 50/46/43 Unit dimensions (WxDxH) mm 805x290x x290x x292x x330x220 Packing dimensions (WxDxH) mm 870x365x x365x X365X x405x330 Weight (Net/Gross) kg 10/11,5 10/11,5 11/13 15/20 Drainage water pipe dia. mm Refrigerant pipe dia. (Liquid side/gas side) mm 6,35/9,52 6,35/12,7 6,35/12,7 9,52/15,88 " 1/4-3/8 1/4-1/2 1/4-1/2 3/8-5/8 Controller Kind Remote controller 27

30 Ducted split units DI-M RANGE FROM 3,5KW UP TO 16KW COMPACT DESIGN ECO FRIENDLY GAS R410A MULTY AIR INLET Functional specs Main features Compact Design The unit is extremely compact (only 210 mm height for the 12Kw model) thus making it possible to install it in rooms with little false ceilings pace. Furthermore the internal units sized 18Kw and 24Kw are only 920mm wide. Flexible Air Intake Ways Air inlet from back standard and from bottom optional. The size of the plate from bottom and flange from back is the same, it s easy for installer to change the air inlet from back to bottom. Fresh Air inlet The Fresh Air intake is standard supplied and it is extremely easy to connect it to the outdoor air with a through hole in order to add outdoor air into the room. 28

31 Design Wired controller WC-M (included) Remote controller RC-M (optional) Special notes Air inlet from the back (standard) Air inlet from bottom (as option) Ideal applications Residences Offices Shops Bars & restaurants Technical data Ducted split units DI-M Model DI12-M DI18-M DI24-M DI30-M DI40-M DI50-M DI60-M Code Power supply V-ph-Hz 220~ ~ ~ ~ ~ ~ ~ Cooling capacity Heating capacity Btu/h KW 3,52 5,28 7,04 8,80 10,55 14,07 16,12 Btu/h KW 3,87 5,57 7,62 9,38 11,61 16,12 17,59 Input Power w 68/57/51 107/65/52 163/93/75 227/142/ /168/ /201/ /223/173 Fan Motor Speed (Hi/Med/Lo) r/min 1220/1010/ /800/ /750/ /700/ /790/ /750/ /830/710 Air flow (Hi/Med/Lo) m3/h 624/485/ /546/- 1260/808/- 1556/1008/- 1848/1103/- 2282/1439/- 2275/-/- External Static Pressure - Nominal Pa External Static Pressure (Min/Max) Pa Noise level (Hi/Med/Lo) db(a) 43/37/31 44/37/33 44/37/34 50/44/42 46/38/35 50/45/40 47/40/38 Unit dimensions (WxDxH) mm 700x635x x635x x635x x775x x775x x865x x865x300 Packing dimensions (WxDxH) mm 915x655x x655x x655x x795x x795x x920x x920x373 Weight (Net/Gross) kg 18.3/ / /32 37/ / /53 47/55 Drainage water pipe dia. mm Refrigerant pipe dia. (Liquid side/gas side) Controller mm 6.35/ / / / / / /19 " 1/4-1/2 1/4-1/2 3/8-5/8 3/8-3/4 3/8-3/4 3/8-3/4 3/8-3/4 Kind Wired controller 29

32 Cassette split units KI-M RANGE FROM 3,4KW UP TO 16KW COMPACT DESIGN ECO FRIENDLY GAS R410A 360 air distribution Functional specs Main features 360 air distribution The innovative 360 Air Flow panel assures even more efficient air distribution. In addition to greater efficiency, the air flow is distributed to the room even more consistently, hence the perceived temperature is constant. Ease of maintenance Thanks to the tilting inspection panel the unit s cleaning and maintenance is even easier. Super compact Models KI40-M, KI50-M, KI60-M have a super compact design thanks to the thickness less than 25 cm (28cm for KI60-M) that make installation easier even in the most challenging settings. Built-in drain pump All models are fitted with built-in drain pump able to lift condensation water up to maximum gradient of 75 cm. 30

33 Design KI12,18,24-M KI40,50,60-M Special notes Remote controller RC-M (included) 360 Air-Flow Easy clean panel Ideal applications Residences Offices Shops Bars & restaurants Technical data Cassette split units KI- M Model KI12- M KI18- M KI24- M KI40- M Code Power supply V- ph- Hz 220~ ~ ~ Cooling capacity Heating capacity Btu/h Btu/h KW KW 3,37 3,52 5,28 5,72 7,04 7,74 10,55 11,73 Input Power w 47.1/37.8/ /65/46 91/80/70 174/145/121 Fan Motor Speed (Hi/Med/Lo) r/min 780/670/ /875/ /510/ /610/540 Air flow (Hi/Med/Lo) m3/h 680/600/ /710/ /1050/ /1600/1400 Noise level (Hi/Med/Lo) db(a) 42/39/35 45/41/38 48/46/41 51/47/43 Unit dimensions (WxDxH) mm 570x570x x570x x840x x840x245 Packing unit dimensions (WxDxH) mm 655x655x x655x x900x x900x265 Panel dimensions (WxDxH) mm 647x647x50 647x647x50 950x950x55 950x950x55 Packing panel dimensions (WxDxH) mm 715x715x x715x x1035x x1035x90 Unit weight (Net/Gross) kg 15/ /20 23/27 25/28.5 Panel weight (Net/Gross) kg 2.5/ /4.5 5/8 5/8 Drainage water pipe dia. mm Refrigerant pipe dia. (Liquid side/gas side) mm 6.35/ / / /19 " 1/4-1/2 1/4-1/2 3/8-5/8 3/8-3/4 Controller Kind Remote control Remote control Remote control Remote control 31

34 Floor and Ceiling split units FI-M ELEGANT AND COMPACT DESIGN RANGE FROM 5KW UP TO 17KW ECO FRIENDLY GAS R410A LOW NOISE Functional specs Main features Floor split units are easy to install, versatile and powerful, ideal for all settings. Its typical application is for offices but its neat and elegant design allows it to be used in residential settings as well or public spaces such as shops or public establishments. Universal spare parts More than 60% of components (such as fans, shells and other metal parts) are universal for the 3 different cases of the FI-M series, which makes spare parts and maintenance easier and cheaper. Wide Air Distribution Radius All Parkair Ceiling/Floor units are equipped with a technology able to distribute the air flow in a remarkably even manner, thus assuring the utmost comfort for the user. Maximum Installation Flexibility The unit may be installed horizontally on the ceiling or vertically against a wall. 32

35 Design Remote controller RC-M (included) Special notes Backlit Display Easy Interface Curved shape Ideal applications Sailing Offices Shops Bars & Restaurants Technical data Floor and Ceiling split units FI-M Model FI18-M FI24-M FI36-M Code Power supply V-ph-Hz 220~ ~ ~ Cooling capacity Heating capacity Btu/h Btu/h KW KW 5,28 5,57 7,04 7,62 10,55 11,58 Input Power w 125/105/85 125/105/85 148/131/122 Fan Motor Speed (Hi/Med/Lo) r/min 1310/1190/ /1190/ /1300/1225 Air flow (Hi/Med/Lo) m3/h 1300/1050/ /1200/ /1400/1250 Noise level (Hi/Med/Lo) db(a) 52/46/41 53/48/42 53/48/44 Unit dimensions (WxDxH) mm 1068x675x x675x x675x235 Packing dimensions (WxDxH) mm 1145x755x x755x313 Weight (Net/Gross) kg 24/29 24/29 29/36 Drainage water pipe dia. mm Refrigerant pipe dia. (Liquid side/gas side) mm 6.35/ / /19 " 1/4-1/2 3/8-5/8 3/8-3/4 Controller Kind Remote controller 33

36 The ideal solution for small home or work but also for local caraterizzati of important dimensions, such as restaurants, public or commercial spaces. Unlike what happens with the refrigerant gas to air conditioners the operation of the hydronic air conditioning systems is via chilled water, which circulates in the ventilation system after being cooled by a cooler.

37 Hydronic systems RCW Chillers and Heat pumps Water-to-Water RCA Heat pumps Air-to-Water FCW Wall mounted fancoils FCD Ducted fancoils FCI Recessed fancoils FCK Cassette fancoils

38 Chillers and Heat Pump RCW Hydronic systems Water-to-Water H2O-INVERTER SYSTEM UP TO 4 INDOOR UNITS RANGE FROM 3KW TO 22KW ECO FRIENDLY GAS R410A LOW NOISE Functional specs Main features Unlike coolant gas conditioners, hydronic conditioning systems operate with chilled water, which circulates in the ventilation system after being chilled by a refrigerator. The body is made with a modular epoxy-powder painted sheet metal case (Pure White RAL 9003), with base in galvanised sheet metal and removable side panels lined with soundproofing mat. The front inspection panel allows easy access to internal components and rapid connection of pressure gauges to suitable service valves for measuring operating pressures. 36

39 Where to install it? Garage Technical room Laundry Understairs Components Electronic controller PLC Modulating valve compressors R410A Rotativi & Scroll Recirculation pump Technical data Chillers Water-to-Water RCW Model RCW-12 RCW-18 RCW-24 RCW-30 RCW-32T RCW-40T RCW-50T RCW-60T Code Cooling capacity BTU/h kw 3,7 5,2 8 8,35 9, ,96 18,74 Power supply V/Ph/Hz f+n 400-3f+n 400-3f+n 400-3f+n Power consumption Kw 0,84 1,15 1,8 1,9 2,62 2,7 3,48 4,16 EER Kw/Kw 4,42 4,52 4,44 4,39 3,68 4,07 4,58 4,5 COP Kw/Kw Sound level dba Number of compressors NR Cooling circuits NR Exchanger (evaporator) Plates Plates Plates Plates Plates Plates Plates Plates Water flow mc/h 0,6 0,9 1,2 1,6 1,6 2 2,5 3 Pressure drop KPa 0,8 1,6 2,8 5,2 5,2 7,4 11,5 15 Exchanger (condenser) Plates Plates Plates Plates Plates Plates Plates Plates Water flow of the hydraulic network (15 C) mc/h 0,19 0,29 0,38 0,5 0,5 0,6 0,79 0,94 Water flow of cooling tower (29-35 C) mc/h 0,6 0,9 1,2 1,6 1,6 2 2,5 3 Water connections 3/4M 3/4M 3/4M 1M 1M 1M 1M 1M Weight Kg Dimensions (WxDxH) cm. 600x420x x420x x420x x420x x420x x420x x420x x420x760 Heat Pumps Water-to-Water RCW-H Model RCW-12H RCW-18H RCW-24H RCW-30H RCW-32TH RCW-40TH RCW-50TH RCW-60TH Code Cooling capacity Heating capacity BTU/h kw 3,7 5,2 8 8,35 9, ,96 18,74 BTU/h kw 4,62 6,4 9,4 10,2 12,49 13,76 19,35 22,7 Power supply V/Ph/Hz f+n 400-3f+n 400-3f+n 400-3f+n Power consumption Kw 0,98 1,33 1,98 2,28 3,21 3,3 4,29 4,7 EER Kw/Kw 4,42 4,52 4,44 4,39 3,68 4,07 4,58 4,5 COP Kw/Kw 4,71 4,81 4,74 4,47 3,89 4,17 4,51 4,4 Sound level dba Number of compressors NR Cooling circuits NR Exchanger (evaporator) Plates Plates Plates Plates Plates Plates Plates Plates Water flow mc/h 0,6 0,9 1,2 1,6 1,6 2 2,5 3 Pressure drop KPa 0,8 1,6 2,8 5,2 5,7 7, ,5 Exchanger (condenser) Plates Plates Plates Plates Plates Plates Plates Plates Water flow of the hydraulic network (15 C) mc/h 0,19 0,29 0,38 0,5 0,5 0,6 0,79 0,94 Water flow of cooling tower (29-35 C) mc/h 0,6 0,9 1,2 1,6 1,6 2 2,5 3 Water connections 3/4M 3/4M 3/4M 1M 1M 1M 1M 1M Weight Kg Dimensions (WxDxH) mm 600x420x x420x x420x x420x x420x x420x x420x x420x760 Performances refer to the following conditions. COOLING: Water inlet temperature condenser side 15 C; Water temperature evaporator side in/outlet 12-7 C. HEATING: Water temperature evaporator side in/outlet C. Water temperature condenser side in/outlet C. Sound pressure levels measured at 1 m from the unit in free field conditions according to ISO See table corrosion resistance contained in the instruction booklet RCW (download from our. Site) to check the suitability of employment in depending on water quality. 37

40 Heat Pumps RCA Hydronic systems Air-to-Water OPERATION FROM -15 TILL +46 C Full DC inverter technology RANGE FROM 5KW UP TO 17KW COOLING AND HEATING Functional specs Main features Series RCA air-cooled chillers with heat pump are designed and manufactured to meet the cooling and heating needs of medium and small users in residential or commercial buildings. The machine is suited to control both water circuits (evaporator condenser) and may therefore be used as water chiller as well as for producing hot water. The summer winter switching takes place via the cooling circuit. The units feature extremely quiet operation and high efficiency and reliability, thanks to the use of exchangers with high exchange surface and scroll compressors with high performance and low noise level. They are available in various set-ups to meet the needs of a wide variety of installation solutions: base or with water pump and integrated water buffer. Condensing unit versions without buffer evaporator are also available. 38

41 Working scheme Summer Winter Components Recirculation pump Expansion vessel Compressors in R410A Full DC Inverter Technical data Heat Pumps Air-to-Water RCA Model RCA-18H RCA-24H RCA-36H RCA-40H RCA-48H RCA-52H Code Cooling capacity Heating capacity BTU/h kw 5,00 7,00 10,50 12,00 14,00 15,50 BTU/h kw 5,50 8,00 12,00 13,20 15,40 17,00 Power supply V 220~ ~ ~ f+n 400-3f+n 400-3f+n Power consumption - Summer season kw 1,55 2,25 2,95 3,38 3,90 4,53 Power consumption - Winter season kw 1,70 2,50 3,14 3,27 4,25 4,85 Maximum power consumption kw 2,80 3,00 4,80 5,00 5,20 5,40 EER kw/kw 3,23 3,12 3,56 3,55 3,59 3,42 COP kw/kw 4,16 3,91 4,37 4,83 4,86 4,41 EER - Recovery values for 65% kw/kw 5,17 4,29 4,40 5,18 4,85 4,49 COP - Recovery values for 65% kw/kw 4,16 3,91 4,37 4,83 4,86 4,41 Water connections " /4 1-1/4 1-1/4 1-1/4 Refrigerant - R410A R410A R410A R410A R410A R410A Sound level dba Exchanger Gas-Water Tipo Water flow mc/h 0,86 1,20 1,72 1,92 2,15 2,49 Pressure drop - water side KPa 15,00 15,00 18,00 18,00 18,00 19,00 Maximum pressure - water side KPa 500,00 500,00 500,00 500,00 500,00 500,00 Operating Limits Outside temperatures Operating temperature limits Liquid product Brazed Plate Heat, Stainless Steel Estate -5 C ; +46 C -5 C ; +46 C -5 C ; +46 C -5 C ; +46 C -5 C ; +46 C -5 C ; +46 C Inverno -15 C ; +27 C -15 C ; +27 C -15 C ; +27 C -15 C ; +27 C -15 C ; +27 C -15 C ; +27 C Estate +4 C ; +20 C +4 C ; +20 C +4 C ; +20 C +4 C ; +20 C +4 C ; +20 C +4 C ; +20 C Inverno +30 C ; +55 C +30 C ; +55 C +30 C ; +55 C +30 C ; +55 C +30 C ; +55 C +30 C ; +55 C Weight Kg Dimensions (WxDxH) mm 990x354x x354x x400x x400x x400x x400x1327 Performances refer to the following conditions. COOLING: cooled water inlet 12 C; Outlet 7 C - External air temperature 35 C dry bulb. HEATING: Water temerature inlet 40 C; outlet 45 C - External air temperature 7 C dry bulb; 6 C wet bulb. The sound pressure values refer to measurements made in semi-reverberant environment with tool placed at 1 m from the source of the noise. 39

42 Wall mounted fancolis FCW Hydronic systems COMPACT DESIGN RANGE FROM 2.4KW UP TO 4.6KW MODERN DESIGN LOW NOISE Functional specs Remote controller TCW (optional) Main features Wall mounted fancoils FCW Model FCW- 20 FCW- 30 FCW- 40 Code Cooling capacity (12.7 C) - Total kw 2,38 2,67 4,6 Cooling capacity (12.7 C) - Sensible kw 1,79 2,03 3,69 Heating capacity (45-40 C) kw 2,5 3 3,8 Air flow (Hi/Med/Lo) mc/h 410/330/ /390/ /753/592 Sound Level (Hi/Med/Lo) db(a) 39,5/36,5/29,5 41/37,5/32 48/45,9/40,2 Dimensions (WxDxH) mm 795x195x x195x x200x298 Weight kg 8,5 8,5 13 Weight with packaging kg Water flow (heating) l/h Pressure losses (heating) kpa 9,85 14,2 29 Water flow (cooling) l/h Pressure losses (cooling) kpa 10,6 13,2 45 Water connections " 1/2"M 1/2"M 1/2"M Performances refer to the following conditions. Cooling: Air temperature 27 C w.b., 19 C w.b. - Water temperature IN 7 C, Water temperature OUT 12 C. Heating: Air temperature 20 C - Water temperature IN 45 C, Water temperature OUT 40 C. Sound pressure levels measured in free field 2 meters away. 40

43 Ducted fancoils FCD Hydronic systems IDEAL FOR LARGE ROOMS COMPACT DESIGN RANGE FROM 6KW UP TO 15KW LOW NOISE Functional specs Wired controller CR11 (optional) Main features Ducted fancoils FCD Model FCD- 60 FCD- 75 FCD- 85 FCD- 100 FCD- 130 FCD- 150 Code Cooling capacity (max) - total kw 6 7,5 8,6 10,3 12,9 15 Cooling capacity (max) - Sensible kw 4,5 5,6 6,1 8,1 9,9 11,1 Heat capacity (45-40 C) kw 6,5 7,9 8,3 11,7 14,4 15,2 Air flow - Maximum mc/h Static pressure available Pa Power supply V Sound level (Min/Max) db(a) Dimensions (WxDxH) mm 800x575x x575x x575x x575x x575x x575x250 Weight (whole set) kg Water flow (heating) l/h Pressure losses (heating) kpa 26,6 32,9 23,4 21,1 32,1 20 Water flow (cooling) l/h Pressure losses (cooling) kpa 28,7 37,8 32, Water connections " 3/4 3/4 3/4 3/4 3/4 3/4 Pipe of condensation mm Performances refer to the following conditions. Cooling: Air temperature 27 C w.b., 19 C w.b. - Water temperature IN 7 C, Water temperature OUT 12 C. Heating: Air temperature 20 C - Water temperature IN 45 C, Water temperature OUT 40 C. Sound pressure levels measured in free field 2 meters away. 41

44 Recessed fancoils FCI Hydronic systems INVISIBLE SOLUTION COMPACT DESIGN RANGE FROM 2KW UP TO 9.6KW LOW NOISE Functional specs Wired controller CR11 (optional) Main features Recessed fancoils FCI Model FCI- 20 FCI- 30 FCI- 40 FCI- 60 FCI- 75 FCI- 90 Code Cooling capacity (max) - total kw 2 3 4,2 6,4 7,5 9,6 Cooling capacity (max) - Sensible kw 1,6 2,4 3,4 5,2 6,4 8,2 Heat capacity (45-40 C) kw 2,1 3 4,5 6,5 8,4 10,4 Air flow - Maximum mc/h Sound level (Min/Max) db(a) Dimensions (WxDxH) mm 670x220x x220x x220x x220x x220x x220x520 Weight (whole set) kg 24,5 30,4 39,5 46,7 52,5 59,3 Water flow (heating) l/h Pressure losses (heating) kpa 14,9 22,7 14,3 21,7 35,9 37,7 Water flow (cooling) l/h Pressure losses (cooling) kpa 16,3 28,2 15,6 24,7 36,1 40 Water connections " 1/2 1/2 1/2 1/2 1/2 1/2 Pipe of condensation mm Performances refer to the following conditions. Cooling: Air temperature 27 C w.b., 19 C w.b. - Water temperature IN 7 C, Water temperature OUT 12 C. Heating: Air temperature 20 C - Water temperature IN 45 C, Water temperature OUT 40 C. Sound pressure levels measured in free field 2 meters away. 42

45 Cassette fancoils FCK Hydronic systems EASY INSTALLATION COMPACT DESIGN RANGE FROM 2.45 KW UP TO 11KW MODERN DESIGN LOW NOISE Functional specs Remote controller TCW (optional) Main features Wired controller CR11 (optional) Cassette fancoils FCK Model FCK- 20 FCK- 40 FCK- 50 FCK- 60 FCK- 80 FCK- 110 Code Cooling capacity (max) - total kw 2,45 4,2 5,35 5,9 7,9 11 Cooling capacity (max) - Sensible kw 2 3,2 3,95 4,4 5,8 8,4 Heat capacity (45-40 C) kw 2,91 4,59 5,34 5,98 8,74 11,48 Power supply V- ph- hz N+PE- 50 Power consumption W 75,3 98,4 112,3 126, Maximum consumption A 0,36 0,46 0,52 0,58 0,65 0,92 Air flow (Hi/Med/Lo) mc/h 660/590/ /510/ /510/ /570/ /1050/ /1800/1560 Sound level (Hi/Med/Lo) db(a) Dimensions (WxDxH) mm 255x575x x575x x575x x575x x825x x950x950 Weight (net) kg 19,1 20,6 20,6 20, Water flow (heating) l/h Pressure losses (heating) kpa 7,9 20,1 31,7 38, Water flow (cooling) l/h Pressure losses (cooling) kpa 7,9 18,9 28,5 33, Water connections " 3/4M 3/4M 3/4M 3/4M 3/4M 3/4M Performances refer to the following conditions. Cooling: Air temperature 27 C w.b., 19 C w.b. - Water temperature IN 7 C, Water temperature OUT 12 C. Heating: Air temperature 20 C - Water temperature IN 45 C, Water temperature OUT 40 C. Sound pressure levels measured in free field 2 meters away. 43

46 Key to functions H2O Inverter Thanks to Parkair s Inverter H2O technology the costs of energy and water are further reduced. It is an electronic water flow and operating pressure control system that thanks to a modulating valve regulates the water flow based on the actual requirements thus reducing consumptions. Turbo The Turbo Function helps reaching the set temperature in the shortest time possible. Sleep Care The Sleep Care function is a precise and intelligent technology for the night. It provides different setting modes for every type of users, such as adults, children and the elderly. With the Sleep Care function your comfort while asleep will certainly be improved. Easy Cleaning Filter The internal unit s filters may be removed just by pressing a button, so they may be cleaned to assure healthy air is diffused in the room. Sleep Mode With the Sleep mode, the set temperature automatically increases (in cooling) by 1 C or decreases (in heating) by 2 C every hour in the first two hours from starting up. You will thus have the ideal temperature throughout your sleep as well as cost savings. Anti Cold Air-Function In heat pump mode the internal unit s fan only starts operating when the evaporator temperature is high enough in order to avoid cold air output. Innver Groover Copper Pipe Special copper pipes assure faster cooling gas flow improving the thermal exchange efficiency up to 30-50% compared to conventional copper pipes. 44

47 Strong Dehumidification Only used on rainy days or in any case in very humid periods, with this mode the ideal room humidity level may be reached without reducing room temperature. Hydrophilic Aluminum Fin Improves the evaporating unit s cooling efficiency, allowing unlimited condensation flow between the exchange fins. Large Fan In addition to the possibility of controlling the air flow output volume, a larger diameter fan reduces the internal unit s noise level thus further reducing fan speed and optimising the air flow. Auto Restart In case of switching off this function will let you save the same temperatures and functions when the unit is switched back on. Self-Diagnosis & Auto-Protection With the self-diagnosis function, errors are detected by the microchip and displayed by the internal unit s LED for easy diagnosis and providing error data to support centres. Anti-Dust Filter This type of filters assures room air purification to protect from the many polluting agents (dusts, pollen etc.). Low Noise Thanks to the high quality standard of components these products assure extremely low noise levels. 45

48 Remote controller RC-G Infrared remote control for the serie WI-G AUTO SWING LCD DISPLAY MANUAL SWING TIMER SETTING TEMPERATURE ADJUSTMENT CANCEL BUTTON DISPLAY LIGHT ON/OFF TURBO FUNCTION ON OFF BUTTON WITH NOCTILUCENT SLEEP MODE FAN SPEED ADJUSTMENT Remote controller RC-M Infrared remote control for the series FI-M, DI-M, KI-M LCD DISPLAY TEMPERATURE ADJUSTMENT GENERAL ON/OFF MODE SELECTION HORIZONTAL SWING VERTICAL SWING AIR DIRECTION FAN SPEED TIMER ON TIMER OFF ECO MODE 46

49 Notes: 47

50 Notes: 48

51 Feel free to contact us to receive further information about our products and energy solutions.

52 Parkair offers a wide range of energy solutions to meet the needs of your projects. Ongoing innovation with cutting-edge products 30 Over 30 years of experience Production 100% Made in Italy Guaranteed support and spare parts Support in design Documentation for incentives 2 Two-year guarantee Free training course 50

53 Feel free to contact us to receive further information about our products and energy solutions. 51

54 Parkair, your perfect partner for successful projects. Rel. 09/ The technical data in this document are not binding. Parkair reserves the right to introduce at any time whatever modifications deemed necessary for improving the product. Parkair srl Via Petrella, 4/c Trezzano sul Naviglio (Milano) - Italia Tel Fax info@parkair.it Website: Please follow our social networks

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw COMFORT HEAT PUMPS AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw climaveneta.com COMFORT HEAT PUMPS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air to water heat pump for outdoor installation,

More information

Aqua 1 plus Air-water heat pumps for domestic hot water production

Aqua 1 plus Air-water heat pumps for domestic hot water production Aqua 1 plus Air-water heat pumps for domestic hot water production THE FLEXIBLE EFFICIENCY is a range of heap pumps for domestic hot water production, fit for small residential applications. It is the

More information

Heat Pump Water Heater Commercial Leaflet 2012

Heat Pump Water Heater Commercial Leaflet 2012 Heat Pump Water Heater Commercial Leaflet 2012 1 Table of contents............... 2 Bosch Group Innovation as a principal Established in 1886 in Stuttgart, Germany, Robert Bosch Corporation has been characterised

More information

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS mini-cassette 18.000 24.000 AUTO MODEL MDH13HLS MDH13HLS Cooling capacity W 3852 3852 Cooling capacity BTU/h 13135 13135 The best Heating technology capacity W in air conditioning 4205 4205 Heating capacity

More information

NUOS RANGE HEAT PUMP WATER HEATERS

NUOS RANGE HEAT PUMP WATER HEATERS RANGE HEAT PUMP WATER HEATERS 1 HOW TO READ THE SYMBOLS The icons have been designed to facilitate the reading of the features of each product. Ariston makes it possible, from the very beginning, to quickly

More information

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw PROCESS CHILLERS AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com PROCESS CHILLERS MAXIMUM EFFICIENCY IN EVERY TYPE OF PROCESS APPLICATION Air cooled liquid chiller for outdoor

More information

Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES

Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES 1 1 2 3 Once again, the Energy Panel team has put all their excitement and enthusiasm to create this new publication. We want to make

More information

ECO HOT WATER Air-water heat pump for domestic hot water with integrated solar panels and remote control via App GB 02. Ecoenergy.

ECO HOT WATER Air-water heat pump for domestic hot water with integrated solar panels and remote control via App GB 02. Ecoenergy. ECO HOT WTER ir-water heat pump for domestic hot water with integrated solar panels and remote control via pp GB 02 Ecoenergy Ideas to install The Eco Hot Water heat pump The EMMETI heating pumps have

More information

Do you want a versatile solution

Do you want a versatile solution Do you want a versatile solution to make significant savings? ESTIA TOSHIBA AIR CONDITIONING RESIDENTIAL HEATING AIR-TO-WATER HEAT PUMP ESTIA hatever you need ESTIA TO MAKE SIGNIFICANT SAVINGS Toshiba

More information

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round AIR TO WATER HEAT PUMPS Hot water and comfortable ambient temperature all year round HEAT PUMP PRINCIPLE CARRIER. A UNITED TECHNOLOGIES COMPANY Whether you need air conditioning for a new building or a

More information

Air to water Heat Pump System

Air to water Heat Pump System Air to water Heat Pump System 2 The heating and cooling systems of the future! A step in the right direction of reducing pollution and CO₂ emissions The increase of CO₂ and other green house gases is a

More information

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw COMFORT CHILLERS AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com COMFORT CHILLERS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air-cooled liquid chiller for outside installation

More information

OLIMPIA SPLENDID S INVERTER DC TECHNOLOGY 100% 80% 70% DC INVERTER AC INVERTER NON INVERTER

OLIMPIA SPLENDID S INVERTER DC TECHNOLOGY 100% 80% 70% DC INVERTER AC INVERTER NON INVERTER SHERP ir-water heat pump COP > 4 DHW 60 C Energy class ErP (1) : RENEWLE TECHNOLOGIES Sherpa uses the heat in the air, and transfers it to system terminals in an efficient manner. For each kw of electricity

More information

PRODUCT RANGE HEAT PUMPS 2012

PRODUCT RANGE HEAT PUMPS 2012 PRODUCT RANGE HEAT PUMPS 2012 TABLE OF CONTENTS Product range...4 Heat pump system benefits...6 Is the heat pump considered as a "RENEWABLE SOURCE"?...8 ENERGETIC advantage of the heat pump...10 ECONOMIC

More information

SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS. Comfort Module 5-20 kw. Choose the easy heating solution!

SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS. Comfort Module 5-20 kw. Choose the easy heating solution! SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS DE L AIR Comfort Module 5-2 kw Choose the easy heating solution! Comfort Module: heating with Carrier system innovation Proper control of heat pumps is key to

More information

Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES

Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES 1 2 3 Heat Merchants have partnered with Energy Panel to offer the most advance technology in Thermodynamic Solar Systems for both residential

More information

Multi Split Systems. Reverse Cycle, Inverter Air Conditioner. Exclusively distributed by

Multi Split Systems. Reverse Cycle, Inverter Air Conditioner. Exclusively distributed by Multi Split Systems Reverse Cycle, Inverter Air Conditioner Exclusively distributed by AUS 13 23 50 www.lennoxaus.com.au NZ 0800 653 330 www.lennoxnz.co.nz 1 As a global leader in comfort solutions, Lennox

More information

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools Dehumidification and ventilation for residential, industrial radiant systems and swimming pools HiDew is proud to present a complete range of dehumidifiers for radiant cooling systems and high performance

More information

The Energy Solutions of Withair Heat Pumps Catalogue 2017 Take Control of Your Energy Future!

The Energy Solutions of Withair Heat Pumps Catalogue 2017 Take Control of Your Energy Future! www.withairmall.com The Energy Solutions of Withair Heat Pumps Catalogue 2017 Take Control of Your Energy Future! Withair offers a wide range of clean energy products and solutions to meet the needs of

More information

NRP MULTIPURPOSE HEAT PUMPS 2 AND 4-PIPE SYSTEMS PLUS PRODUCTION OF DOMESTIC HOT WATER

NRP MULTIPURPOSE HEAT PUMPS 2 AND 4-PIPE SYSTEMS PLUS PRODUCTION OF DOMESTIC HOT WATER NRP MULTIPURPOSE HEAT PUMPS AND 4-PIPE SYSTEMS PLUS PRODUCTION OF DOMESTIC HOT WATER Multipurpose air cooled units with axial fans. For external installation. High efficiency version. NRP MULTIPURPOSE

More information

HT V2 HT Split

HT V2 HT Split Scroll compressor Refrigerant R07C Aqu@Scop HT V Aqu@Scop HT Split High Temperature Air-to-Water Heat Pumps Models -, -7 and 8-9.0 to 7.9kW Aqu@Scop HT V / Aqu@Scop HT Split Installation examples - Single

More information

Air to water Heat Pump System

Air to water Heat Pump System Air to water Heat Pump System 2 The heating and cooling systems of the future! A step in the right direction of reducing pollution and CO₂ emissions The increase of CO₂ and other green house gases is a

More information

High temperature air-to-water heat pumps

High temperature air-to-water heat pumps Designed to replace conventional boilers and produce domestic hot water 4 High temperature hot water (+65 C) 4 Winter operation (-20 C) 4 High energy efficiency (CP) 4 Compact and quiet 4 Scroll compressors

More information

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB R407C EASY_R Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans 5,2 41,5 kw T_ESY_R_0508_GB EASY_R R407C INDEX WORKING LIMITS... 3 SERIES IDENTIFICATION... 4 MODEL

More information

Call or visit solarshop.com.au

Call or visit solarshop.com.au Solar HYBRID AIR CONDITIONING Call 133 765 or visit solarshop.com.au Copyright 2012, Solarshop Group Pty Ltd. The contents of this brochure are protected by copyright law. Copyright in this material resides

More information

Heat Pump Technology. Air Source, Water Source and Ground Source. Optimised heat pumps for residential and commercial applications

Heat Pump Technology. Air Source, Water Source and Ground Source. Optimised heat pumps for residential and commercial applications Heat Pump Technology Air Source, Water Source and Ground Source Optimised heat pumps for residential and commercial applications ICS Cool Energy Limited has nearly 25 years experience in supplying and

More information

The future is in the air

The future is in the air The future is in the air ecological air conditioners Dianclima is looking forward to the third generation ; that one of our sons, eager for clean air, and aware of respect for nature and world health,

More information

HYDRONIC RESIDENTIAL

HYDRONIC RESIDENTIAL HYDRONIC RESIDENTIAL Chillers, reversible heat pumps and modular units for small and medium applications. Climaveneta. brand of Mitsubishi Electric Hydronics & IT Cooling Systems, presents the mini chiller

More information

Product Line Introduction. Karl Zhang Technical support engineer

Product Line Introduction. Karl Zhang Technical support engineer Product Line Introduction Karl Zhang Technical support engineer Air Conditioning Solutions Heating & Hot Water Solutions Control Solutions Air Conditioning Solutions Residential Application Commercial

More information

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories > HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION Available range Unit type IP Reversible heat pump (reversible on the refrigerant side) ECO-FRIENDLY REFRIGERANT GAS Versions (heat recovery) VB Base

More information

PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED

PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED Just feel well Renewable Energy MADE IN EUROPE A ++ + PRODUCTS High efficiency: ηs %. High flexibily due to DC Inverter compressor: operation optimised

More information

Also available with the new i-life R-Slim inverter and radiant panel version. Perfect comfort. Silent operation. Real energy savings

Also available with the new i-life R-Slim inverter and radiant panel version. Perfect comfort. Silent operation. Real energy savings The new i-life Slim fan coil, with inverter technology for heating, cooling and dehumidifying. Its elegant design with only 13 cm depth makes i-life Slim the perfect solution for residential applications.

More information

Tower Green HE Hybrid

Tower Green HE Hybrid Tower Green HE Hybrid Condensing Floor-standing Boilers A NEW A NEW Residential Heating plug & play XL TOWER GREEN HE HYBRID / Condensing Floor-standing Boilers Tower Green HE Hybrid: the hybrid technology

More information

Process glycol chillers

Process glycol chillers Process glycol chillers The most advanced solutions in refrigeration technology. According to normative EN378 y F-Gas Compact chillers for outdoor installation Natural refrigerant Integrated hydraulic

More information

SHERPA. Air-water split heat pump. COP > 4 ACS a 60 C

SHERPA. Air-water split heat pump. COP > 4 ACS a 60 C Air-water split heat pump. COP > 4 ACS a 60 C Energy class: 35 55 RENEWALE TECHNOLOGIES Sherpa uses the heat in the air, and transfers it to system terminals in an efficient manner. For each kw of electricity

More information

SHERPA DHW 75. Th e multifunctional air-water split heat pump. COP > 4 DHW 75 C

SHERPA DHW 75. Th e multifunctional air-water split heat pump. COP > 4 DHW 75 C SHERPA Th e multifunctional air-water split heat pump. PATENTED TECHNOLOGY The combination of an inverter air-water heat pump together with a water-water heat pump allows heating/ and high temperature

More information

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY Easy and fast installation Hydronic module available Compact, reliable and efficient Nominal cooling capacity : 8-40 kw Nominal heating capacity : 17-40 kw 50 410A Cooling or heating USE The air-to-water

More information

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB T_SMT_0609_GB 4,9 49,5 kw Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans INDEX SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3 CE CONFORMITY... 3 WORKING

More information

DAIKIN 17 SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEM S. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

DAIKIN 17 SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEM S. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY DAIKIN 17 SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEM S 17 SEER 9.0 HSPF / 11.5 EER HEAT PUMP AND COOLING ONLY Today, the air is perfect. Perfect temperature. Perfect humidity. Perfectly clean and fresh,

More information

AQUASNAP JUNIOR 30RHV

AQUASNAP JUNIOR 30RHV High-Efficiency Air-To-Water Heat Pumps Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. AQUASNAP JUNIOR 3RHV 6-11

More information

AQUAHEAT ADVANCE SPLIT

AQUAHEAT ADVANCE SPLIT AQUAHEAT ADVANCE SPLIT HEAT PUMP INVERTER SPLIT SYSTEM AN AIRWELL GROUP COMPANY Indoor unit Outdoor unit 005 PRODUCT ADVANTAGES INVERTER technology R4A refrigerant 2 versions available: heating only /

More information

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01 b cool manufacturers of air-conditioning equipment ltd BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION Ver. 1.01 Ver. 3.02 01_18 BCool# 1 brt c/h r407c / r410a

More information

GAS ABSORPTION HEAT PUMP

GAS ABSORPTION HEAT PUMP G A H P VV GAS ABSORPTION HEAT PUMP Water Cooled Gas Fired Absorption Heat Pump > Make a choice to build up the future G A H P VV GAS ABSORPTION HEAT PUMP WATER COOLED GAS FIRED ABSORPTION HEAT T PUMP

More information

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS Total heat recovery multi-purpose units LCP Outdoor monobloc air-water unit LCP - kw Heating, cooling, domestic hot water one single system to meet all kinds of needs. Total heat recovery multi-purpose

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -

More information

Be sustainable while protecting your business

Be sustainable while protecting your business Be sustainable while protecting your business Aquaflair 50Hz Air-cooled chillers and free-cooling chillers with double screw compressors and HFO R1234ze refrigerant (400V/3ph/50Hz) 300-1000 kw Aquaflair

More information

DSS SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEMS. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

DSS SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEMS. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY DSS SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEMS 17 SEER 9.0 HSPF / 11.5 EER HEAT PUMP AND COOLING ONLY Elegant and stylish wall mounted unit providing high efficiency and comfort DSS Series single-zone

More information

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling Air Conditioners Heating & Cooling C o n c e a l e d C e i l i n g U n i t Energy label:» Up to class A Heat pump system Seasonal inverter technology Flexible duct system for large areas Neatly concealed»

More information

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS Energy saving thanks to a total recovery p Cooling Heating/DHW h Galletti multi-purpose heat pumps are total recovery units used for a simultaneous hot and

More information

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery. PRODUCT DATA COMPACT P - SERIES BY NILAN Domestic Passive heat recovery Active heat recovery Ventilation < 300 m 3 /h Comfort heating Comfort cooling Sanitary hot water production Heating THE VENTILATION

More information

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING Free cooling modules for 2 700V to 1100V POWER 1200V to 1800V Cooling capacity: 185 to 485 kw Cooling only Hydraulic module Free cooling ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY L'ENVIRONNEMENT

More information

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating 2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER AIR-TO-WATER HEAT PUMP cooling - heating MINI CHILLER Highly efficient heat pump for summer and winter air conditioning. Ideal for residential and commercial

More information

CRIMSON & CRIMSON MAX

CRIMSON & CRIMSON MAX High efficiency water/water and geothermal heat pumps 5 114 General High efficiency water/water and geothermal heat pumps. Ideal for heating, cooling and production of domestic hotwater with total or partial

More information

THE HEAT PUMP CHOICE OF PROFESSIONALS

THE HEAT PUMP CHOICE OF PROFESSIONALS THE HEAT PUMP CHOICE OF PROFESSIONALS T H E E N E R G Y E F F I C I E N T H E AT I N G S Y S T E M TIME FOR ENERGY EFFICIENT AND INNOVATIVE SOLUTIONS Expectations of consumers are changing. With the high

More information

SWP. Water heater with SWP heat pump Hot water finally costs less. + Efficiency + Savings + Wellbeing

SWP. Water heater with SWP heat pump Hot water finally costs less. + Efficiency + Savings + Wellbeing SWP Water heater with SWP heat pump Hot water finally costs less. + Efficiency + Savings + Wellbeing SWP AERMEC all the hot water you could want, with particularly high efficiency levels AERMEC SWP heats

More information

MAC-D R410A Series Air-cooled Modular Chiller/Heat pump

MAC-D R410A Series Air-cooled Modular Chiller/Heat pump Catalogue MAC-D-2013 (50Hz) MAC-D R410A Series Air-cooled Modular Chiller/Heat pump Model: Refrigerant: Cooling Capacity: Heating Capacity: MAC210D5-MAC1680D5 MAC230D5-MAC1840D5 MAC210DR5-MAC1680DR5 MAC230DR5-MAC1840DR5

More information

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron. Whole of Home Ducted comfort, for when space is at a premium. That s better. That s Actron. ActronAir. Because Australia needs Australian air conditioning. The year 1984 saw Advanced Australia Fair become

More information

EXPLORER HEAT PUMP WATER HEATER. A+ in READY Smart heat pump

EXPLORER HEAT PUMP WATER HEATER. A+ in READY Smart heat pump HEAT PUMP WATER HEATER EXPLORER 7% energy savings * Wide temperature range of use (- to + C) ACI hybrid anti-corrosion protection Smart energy consumption control Remote piloting with Cozytouch technology

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02

More information

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw SPECIFICATION GUIDE NEOSYS Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw Air-to-water Heat Pump for outdoor installation (NAH) Nominal cooling capacity:

More information

Geolo THE GROUND SOURCE HEAT PUMP PLUSES

Geolo THE GROUND SOURCE HEAT PUMP PLUSES Geolo THE GROUND SOURCE HEAT PUMP PLUSES RENEWABLE TECHNOLOGIES Geolo is able to exploit the Energy present in the water and underground thanks to the geothermal exchangers. Soil and water absorb the solar

More information

NATURAL HEATING MACHINE

NATURAL HEATING MACHINE www.lgeaircon.com LG Electronics Air Conditioning & Energy Solution 20 Yoido-dong, Youngdungpo-gu, Yoido P.O.Box 55 Seoul 150-721, Korea Phone: 82-2-777-761 http://www.lgeaircon.com For continual product

More information

VERTINOX. AISI 316 stainless steel accumulators with one or two heat exchangers, fixed or removable type

VERTINOX. AISI 316 stainless steel accumulators with one or two heat exchangers, fixed or removable type 27-0514 VERTINOX AISI 316 stainless steel accumulators with one or two heat exchangers, fixed or removable type VERTINOX: THE RELIABLE HEART The boiler for hot sanitary water production is the heart of

More information

Oilon Ground Source Heat Pumps

Oilon Ground Source Heat Pumps Oilon Ground Source Heat Pumps Homes - Large properties - Industry Ground source heat pump Oilon CUBE For properties 90-400 m² Extremely high domestic hot water production The Oilon CUBE ground source

More information

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron. Whole of Home Ducted comfort, for when space is at a premium. That s better. That s Actron. ActronAir. Because Australia needs Australian air conditioning. The year 1984 saw Advanced Australia Fair become

More information

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata EKS/HE Refrigerant R410A GWP=2.088 Scroll Compressor Shell & Tube exchanger Axial fan Brazed plate heat exchanger MultiScroll Air-cooled liquid chillers High efficiency Solution B - Base I - Integrata

More information

COMFORT HYDRONIC TERMINALS

COMFORT HYDRONIC TERMINALS COMFORT HYDRONIC TERMINALS i i-chd NEW GENERATION CASSETTE WITH EC HIGH EFFICIENCY MOTOR. CENTRIFUGAL FAN WITH CONTINUOUS AIR FLOW REGULATION AND SPEED MODULATION. ENERGY CONSUMPTION REDUCED BY MORE THAN

More information

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools Dehumidification and ventilation for residential, industrial radiant systems and swimming pools HiDew is proud to present a complete range of dehumidifiers for radiant cooling systems, industrial processes,

More information

30AW. Reversible Air to Water Heat Pump PRODUCT SELECTION DATA. Monobloc inverter. Compact, reliable and efficient. More than a Heat Pump

30AW. Reversible Air to Water Heat Pump PRODUCT SELECTION DATA. Monobloc inverter. Compact, reliable and efficient. More than a Heat Pump PRODUCT SELECTION DATA Monobloc inverter Compact, reliable and efficient More than a Heat Pump Reversible Air to Water Heat Pump 0AW CARRIER participates in the ECP programme for LCP/HP Check ongoing validity

More information

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS RAH 602 Ka + CF + GP 62 Above picture is only indicative and is not binding.

More information

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a Air-Cooled Variable Speed Drive Screw Chillers Super Efficient Super Quiet Cooling Capacity Range 540-1405 kw R134a World s first low sound Air-Cooled variable speed drive screw chiller The recognition

More information

and sanitary hot water Catalogue 2009

and sanitary hot water Catalogue 2009 heating, COOLING and sanitary hot water Catalogue 2009 LG Electronics Magyar Kft. H-1097 Budapest, Könyves K. krt. 3/a. (+36-1) 455-6060 www.lg.hu www.lgeaircon.com http://lgacademy.csx.hu For continual

More information

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 35 to 700 kw 410A Cooling Operation DYNACIAT - DYNACIAT POWER

More information

Installation Manual. Instrucciones de instalación y manual de usuario 1

Installation Manual. Instrucciones de instalación y manual de usuario 1 Installation Manual Instrucciones de instalación y manual de usuario 1 Installation instructions and user manual V8 2 INDEX 1 GENERAL SAFETY WARNINGS... 4 2 OPERATING PRINCIPLE... 5 3 TECHNICAL FEATURES...

More information

MAC-A R410A Series Air cooled Modular Chiller

MAC-A R410A Series Air cooled Modular Chiller Catalogue MAC R410A 2011(60Hz) MAC-A R410A Series Air cooled Modular Chiller Model: Refrigerant: Co ling Capacity: MAC210A5 R410A 72kW Overview Based on the successful McQuay air-cooled modular chiller,

More information

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value. Midea Ducted and Cassette Split Systems Maximum versatility, maximum value. Year round comfort, all around the house A Midea ducted inverter system puts total climate control right at your fingertips.

More information

Advance Split

Advance Split Engineering Data Manual Aqu@Scop Advance Split Air-to-Water DC Inverter Split Heat Pumps Models 005, 008, 012 & 014 2 to 16 kw Strength Points Most efficient heating technology with variable speed compressor.

More information

BLUEWAY DC INVERTER AIR TO WATER HEAT PUMP

BLUEWAY DC INVERTER AIR TO WATER HEAT PUMP BLUEWAY DC INVERTER AIR TO WATER HEAT PUMP 1 Enjoy comfortable life with BLUEWAY DC Inverter Air to Water Heat Pump is an innovative system of house heating, domestic hot water and even space cooling,

More information

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling Air Conditioners Heating & Cooling C o n c e a l e d C e i l i n g U n i t Energy label:» Up to class A Heat pump system Seasonal inverter technology Flexible duct system for large areas Neatly concealed»

More information

New Panasonic Aquarea DHW. Domestic Hot Water Tanks

New Panasonic Aquarea DHW. Domestic Hot Water Tanks New Panasonic Aquarea DHW. Domestic Hot Water Tanks DHW tank with built-in Heat Pump. The Heat Pump is one of the most energy efficient and cost effective methods of water heating. The pump is mounted

More information

SMC DUCTED. High Performance AIR CONDITIONING SYSTEMS

SMC DUCTED. High Performance AIR CONDITIONING SYSTEMS SMC DUCTED High Performance AIR CONDITIONING SYSTEMS NEW SLIM DUCTED SYSTEM h 220 mm 1 Slim and compact The new SMC Ducted system is just 220mm in height for sizes up to 5.94 kw and 310mm for larger systems,

More information

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING PANASONIC LEADS THE WAY Ducted Air Conditioning Specialists With more than 60 years of experience, exporting to more than 120 countries around the world,

More information

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING A Better Life. A Better World Please read the Installation Instructions carefully before installing the unit, and the Operating Instructions before using it. Specifications are subject to change without

More information

Product catalogue 2014 INNOVATIVE IDEAS FOR SMART SAVING

Product catalogue 2014 INNOVATIVE IDEAS FOR SMART SAVING Product catalogue 2014 INNOVATIVE IDEAS FOR SMART SAVING Once again, the Energy Panel team has put all their excitement and enthusiasm into creating this new publication. We want to make you aware of technology,

More information

SA 1 INDEX Available versions...pag. 4 Structure of electro-galvanized and painted steel sheet...pag. 5 Ecological refrigerant R410A...pag. 5 Scroll compressors...pag. 6 Condenser coils...pag. 6 Brazed

More information

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron. Whole of Home Ducted comfort, for when space is at a premium. That s better. That s Actron. ActronAir. Because Australia needs Australian air conditioning. The year 198 saw Advanced Australia Fair become

More information

High efficiency air to water Heat pumps LZT series

High efficiency air to water Heat pumps LZT series High efficiency air to water Heat pumps LZT series 01/2009 THE COMPANY HIDROS was born in 1993 as a trading company involved in the market of dehumidification and humidification of the air. Quite soon

More information

Heating High/Nom./Low dba 36/33/29 44/39/33 45/41/35 45/41/37 Refrigerant Type R-410A Piping

Heating High/Nom./Low dba 36/33/29 44/39/33 45/41/35 45/41/37 Refrigerant Type R-410A Piping Heating & Cooling OPTIMIZED FOR SEASONAL EFFICIENCY INDOOR UNIT FCQG71E FCQG100E FCQG125E FCQG140E Cooling capacity Nom. kw 7.1 3 10.0 3 12.0 14.0 3 Heating capacity Nom. kw 8.0 4 11.2 4-16 4 Power input

More information

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs next generation C precision controlled industrial process chillers cooling capacity: 6824 -,255,668 BTU /hr (0.6-04.6 tons) cooling capacity: 6,824 -,254,303 BTU/hr (0.6-04.5 tons) precision controlled

More information

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue cert. n. 0545 Product is subject to and complies with Regulation (UE) N.327/2011 Fan Coil Unit Cassette SkyStar Jumbo ECM technical catalogue SkyStar Jumbo ECM Table of contents SkyStar Jumbo ECM TABLE

More information

H4T R410A. refrigerant

H4T R410A. refrigerant H4T INDEX Polyvalent unit working modes...pag. 4 Available versions...pag. 4 Structure of electro-galvanized and painted steel sheet...pag. 5 Ecological refrigerant R410A...pag. 5 Scroll compressors...pag.

More information

Chillers EWAQ-E-/F- EWYQ-F- Air cooled multi-scroll chillers and heat pumps

Chillers EWAQ-E-/F- EWYQ-F- Air cooled multi-scroll chillers and heat pumps Chillers Air cooled multi-scroll chillers and heat pumps High efficiency values both in cooling and heating mode Extremely wide operating range, outside ambient temperatures up to 52 C One or two refrigerant

More information

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling Air Conditioners Heating & Cooling 4 - W a y B l o w C e i l i n g M o u n t e d C a s s e t t e Energy label:» Up to class A Heat pump system Inverter technology Fits precisely» in standard modules» of

More information

PRODUCT GUIDE

PRODUCT GUIDE PRODUCT GUIDE 01.2017 Cooling Heating CHAPTER 1 AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS FOR RESIDENTIAL & LIGHT COMMERCIAL APPLICATION Power (kw) Page IACAK/II/WP 101.5 106 0 58 115 A CLASS energy efficiency

More information

Attractive, slim, versatile & WITHOUT OUTDOOR UNIT

Attractive, slim, versatile & WITHOUT OUTDOOR UNIT Attractive, slim, versatile & WITHOUT OUTDOOR UNIT MONOBLOCCO RÊVE SINGLE DUCT CONDITIONER CONDENSED Only 2 holes in the wall are needed to connect the air-condensed Rêve model with the outside, as long

More information

SIMPLICITY OR FULL MODULARITY?

SIMPLICITY OR FULL MODULARITY? D E S I G N I N G I N N O V A T I V E S O L U T I O N S AIR CONDITIONING & HEATING SOLUTIONS SIMPLICITY OR FULL MODULARITY? IDROFAN, BECAUSE YOU SHOULD NOT HAVE TO CHOOSE. Hydronic ducted fan coils Cooling

More information

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS Aurora Wall Split Systems. Built for one of the harshest climates on Earth. Aurora Wall Split Systems The leading Australian owned air conditioning

More information

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient PRODUCT SELECTION DATA Easy and fast installation Compact, reliable and efficient Class A variable speed circulator available Air-Cooled Liquid Chillers 0RB 008-015 CARRIER participates in the ECP programme

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING

More information